WorldWideScience

Sample records for standard analytical techniques

  1. Does leaf chemistry differentially affect breakdown in tropical vs temperate streams? Importance of standardized analytical techniques to measure leaf chemistry

    Science.gov (United States)

    Marcelo Ard& #243; n; Catherine M. Pringle; Susan L. Eggert

    2009-01-01

    Comparisons of the effects of leaf litter chemistry on leaf breakdown rates in tropical vs temperate streams are hindered by incompatibility among studies and across sites of analytical methods used to measure leaf chemistry. We used standardized analytical techniques to measure chemistry and breakdown rate of leaves from common riparian tree species at 2 sites, 1...

  2. Advanced analytical techniques

    International Nuclear Information System (INIS)

    Mrochek, J.E.; Shumate, S.E.; Genung, R.K.; Bahner, C.T.; Lee, N.E.; Dinsmore, S.R.

    1976-01-01

    The development of several new analytical techniques for use in clinical diagnosis and biomedical research is reported. These include: high-resolution liquid chromatographic systems for the early detection of pathological molecular constituents in physiologic body fluids; gradient elution chromatography for the analysis of protein-bound carbohydrates in blood serum samples, with emphasis on changes in sera from breast cancer patients; electrophoretic separation techniques coupled with staining of specific proteins in cellular isoenzymes for the monitoring of genetic mutations and abnormal molecular constituents in blood samples; and the development of a centrifugal elution chromatographic technique for the assay of specific proteins and immunoglobulins in human blood serum samples

  3. Assessing the service quality of Iran military hospitals: Joint Commission International standards and Analytic Hierarchy Process (AHP) technique.

    Science.gov (United States)

    Bahadori, Mohammadkarim; Ravangard, Ramin; Yaghoubi, Maryam; Alimohammadzadeh, Khalil

    2014-01-01

    Military hospitals are responsible for preserving, restoring and improving the health of not only armed forces, but also other people. According to the military organizations strategy, which is being a leader and pioneer in all areas, providing quality health services is one of the main goals of the military health care organizations. This study was aimed to evaluate the service quality of selected military hospitals in Iran based on the Joint Commission International (JCI) standards and comparing these hospitals with each other and ranking them using the analytic hierarchy process (AHP) technique in 2013. This was a cross-sectional and descriptive study conducted on five military hospitals, selected using the purposive sampling method, in 2013. Required data collected using checklists of accreditation standards and nominal group technique. AHP technique was used for prioritizing. Furthermore, Expert Choice 11.0 was used to analyze the collected data. Among JCI standards, the standards of access to care and continuity of care (weight = 0.122), quality improvement and patient safety (weight = 0.121) and leadership and management (weight = 0.117) had the greatest importance, respectively. Furthermore, in the overall ranking, BGT (weight = 0.369), IHM (0.238), SAU (0.202), IHK (weight = 0.125) and SAB (weight = 0.066) ranked first to fifth, respectively. AHP is an appropriate technique for measuring the overall performance of hospitals and their quality of services. It is a holistic approach that takes all hospital processes into consideration. The results of the present study can be used to improve hospitals performance through identifying areas, which are in need of focus for quality improvement and selecting strategies to improve service quality.

  4. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  5. Nuclear techniques in analytical chemistry

    CERN Document Server

    Moses, Alfred J; Gordon, L

    1964-01-01

    Nuclear Techniques in Analytical Chemistry discusses highly sensitive nuclear techniques that determine the micro- and macro-amounts or trace elements of materials. With the increasingly frequent demand for the chemical determination of trace amounts of elements in materials, the analytical chemist had to search for more sensitive methods of analysis. This book accustoms analytical chemists with nuclear techniques that possess the desired sensitivity and applicability at trace levels. The topics covered include safe handling of radioactivity; measurement of natural radioactivity; and neutron a

  6. Does leaf chemistry differentially affect breakdown in tropical versus temperate streams? Importance of standardized analytical techniques to measure leaf chemistry

    Science.gov (United States)

    Marcelo Ardon; Catherine M. Pringle; Susan L. Eggert

    2009-01-01

    Comparisons of the effects of leaf litter chemistry on leaf breakdown rates in tropical vs temperate streams are hindered by incompatibility among studies and across sites of analytical methods used to...

  7. Nuclear analytical techniques in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future.

  8. Nuclear analytical techniques in medicine

    International Nuclear Information System (INIS)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future

  9. Hyphenated analytical techniques for materials characterisation

    Science.gov (United States)

    Armstrong, Gordon; Kailas, Lekshmi

    2017-09-01

    This topical review will provide a survey of the current state of the art in ‘hyphenated’ techniques for characterisation of bulk materials, surface, and interfaces, whereby two or more analytical methods investigating different properties are applied simultaneously to the same sample to better characterise the sample than can be achieved by conducting separate analyses in series using different instruments. It is intended for final year undergraduates and recent graduates, who may have some background knowledge of standard analytical techniques, but are not familiar with ‘hyphenated’ techniques or hybrid instrumentation. The review will begin by defining ‘complementary’, ‘hybrid’ and ‘hyphenated’ techniques, as there is not a broad consensus among analytical scientists as to what each term means. The motivating factors driving increased development of hyphenated analytical methods will also be discussed. This introduction will conclude with a brief discussion of gas chromatography-mass spectroscopy and energy dispersive x-ray analysis in electron microscopy as two examples, in the context that combining complementary techniques for chemical analysis were among the earliest examples of hyphenated characterisation methods. The emphasis of the main review will be on techniques which are sufficiently well-established that the instrumentation is commercially available, to examine physical properties including physical, mechanical, electrical and thermal, in addition to variations in composition, rather than methods solely to identify and quantify chemical species. Therefore, the proposed topical review will address three broad categories of techniques that the reader may expect to encounter in a well-equipped materials characterisation laboratory: microscopy based techniques, scanning probe-based techniques, and thermal analysis based techniques. Examples drawn from recent literature, and a concluding case study, will be used to explain the

  10. Quality system implementation for nuclear analytical techniques

    International Nuclear Information System (INIS)

    2004-01-01

    techniques. The methodology provided is appropriate for: (a) Analysis of radionuclides as in alpha, beta, and gamma spectrometry for environmental and human-made radioactivity investigations; (b) Analysis of trace, minor and major elements using nuclear and related analytical techniques such as neutron activation analysis, X ray fluorescence, PIXE, etc. This training guidebook can be used by staff of analytical laboratories as a starting kit to better understand the quality assurance and quality control principles as prescribed in the ISO 17025 standard. It follows a logical order related to practical laboratory work rather than the formal clauses as given by the standard. It can be used as a stand alone textbook. However, in some cases, cross-reference is given to the ISO 17025 clauses hence it is recommended to consult the ISO standard for exact wording of specific requirements

  11. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  12. Analytical pervaporation: a key technique in the enological laboratory.

    Science.gov (United States)

    Luque de Castro, Maria D; Luque-García, Jose L; Mataix, Eva

    2003-01-01

    This paper reviews the use of analytical pervaporation (defined as the integration of 2 different analytical separation principles, evaporation and gas diffusion, in a single micromodule) coupled to flow-injection manifolds for the determination of analytes of interest in enology; the review discusses the advantages that these techniques can provide in wine analytical laboratories. Special attention is given to methods that enable the determination of either of 2 volatile analytes, or of one volatile analyte and one nonvolatile analyte by taking advantage of the versatility of the designed approaches. In a comparison of these methods with the official and/or standard methods, the results showed good agreement. In addition, the new methods offer improvements in linear determination range, quantitation limit, precision, rapidity, and potential for full automation. Thus, this review demonstrates that although the old technologies used in wine analytical laboratories may be supported by official and standard methods, they should be replaced by properly validated, new, and automated technologies.

  13. Analytical research using synchrotron radiation based techniques

    International Nuclear Information System (INIS)

    Jha, Shambhu Nath

    2015-01-01

    There are many Synchrotron Radiation (SR) based techniques such as X-ray Absorption Spectroscopy (XAS), X-ray Fluorescence Analysis (XRF), SR-Fourier-transform Infrared (SRFTIR), Hard X-ray Photoelectron Spectroscopy (HAXPS) etc. which are increasingly being employed worldwide in analytical research. With advent of modern synchrotron sources these analytical techniques have been further revitalized and paved ways for new techniques such as microprobe XRF and XAS, FTIR microscopy, Hard X-ray Photoelectron Spectroscopy (HAXPS) etc. The talk will cover mainly two techniques illustrating its capability in analytical research namely XRF and XAS. XRF spectroscopy: XRF spectroscopy is an analytical technique which involves the detection of emitted characteristic X-rays following excitation of the elements within the sample. While electron, particle (protons or alpha particles), or X-ray beams can be employed as the exciting source for this analysis, the use of X-ray beams from a synchrotron source has been instrumental in the advancement of the technique in the area of microprobe XRF imaging and trace level compositional characterisation of any sample. Synchrotron radiation induced X-ray emission spectroscopy, has become competitive with the earlier microprobe and nanoprobe techniques following the advancements in manipulating and detecting these X-rays. There are two important features that contribute to the superb elemental sensitivities of microprobe SR induced XRF: (i) the absence of the continuum (Bremsstrahlung) background radiation that is a feature of spectra obtained from charged particle beams, and (ii) the increased X-ray flux on the sample associated with the use of tunable third generation synchrotron facilities. Detection sensitivities have been reported in the ppb range, with values of 10 -17 g - 10 -14 g (depending on the particular element and matrix). Keeping in mind its demand, a microprobe XRF beamline has been setup by RRCAT at Indus-2 synchrotron

  14. Nuclear forensics: strategies and analytical techniques

    International Nuclear Information System (INIS)

    Marin, Rafael C.; Sarkis, Jorge E.S.; Pestana, Rafael C.B.

    2013-01-01

    The development of nuclear forensics as a field of science arose in response to international demand for methods to investigate the illicit trafficking of nuclear materials. After being seized, unknown nuclear material is collected and analyzed by a set of analytical methods. The fingerprints of these materials can be identified and further used during the investigations. Data interpretation is an extensive process aiming to validate the hypotheses made by the experts, and can help confirm the origin of seized nuclear materials at the end of the process or investigation. This work presents the set of measures and analytical methods that have been inherited by nuclear forensics from several fields of science. The main characteristics of these methods are evaluated and the analytical techniques employed to determine the fingerprint of nuclear materials are described. (author)

  15. Nuclear analytical techniques in Cuban Sugar Industry

    International Nuclear Information System (INIS)

    Diaz Riso, O.; Griffith Martinez, J.

    1996-01-01

    This paper is a review concerning the applications of Nuclear Analytical Techniques in the Cuban sugar industry. The most complete elemental composition of final molasses (34 elements ) and natural zeolites (38) this last one employed as an auxiliary agent in sugar technological processes has been performed by means of Instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence Analysis (XRFA). The trace elements sugar cane soil plant relationship and elemental composition of different types of Cuban sugar (rawr, blanco directo and refine) were also studied. As a result, valuable information referred to the possibilities of using these products in animal and human foodstuff so as in other applications are given

  16. 40 CFR 141.27 - Alternate analytical techniques.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Alternate analytical techniques. 141... § 141.27 Alternate analytical techniques. (a) With the written permission of the State, concurred in by the Administrator of the U.S. EPA, an alternate analytical technique may be employed. An alternate...

  17. Nuclear analytical techniques applied to forensic chemistry

    International Nuclear Information System (INIS)

    Nicolau, Veronica; Montoro, Silvia; Pratta, Nora; Giandomenico, Angel Di

    1999-01-01

    Gun shot residues produced by firing guns are mainly composed by visible particles. The individual characterization of these particles allows distinguishing those ones containing heavy metals, from gun shot residues, from those having a different origin or history. In this work, the results obtained from the study of gun shot residues particles collected from hands are presented. The aim of the analysis is to establish whether a person has shot a firing gun has been in contact with one after the shot has been produced. As reference samples, particles collected hands of persons affected to different activities were studied to make comparisons. The complete study was based on the application of nuclear analytical techniques such as Scanning Electron Microscopy, Energy Dispersive X Ray Electron Probe Microanalysis and Graphite Furnace Atomic Absorption Spectrometry. The essays allow to be completed within time compatible with the forensic requirements. (author)

  18. New analytical techniques for cuticle chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schulten, H.R. [Fachhochschule Fresenius, Dept. of Trace Analysis, Wiesbaden (Germany)

    1994-12-31

    1) The analytical methodology of pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) and direct pyrolysis-mass spectrometry (Py-MS) using soft ionization techniques by high electric fields (FL) are briefly described. Recent advances of Py-GC/MS and Py-FIMS for the analyses of complex organic matter such as plant materials, humic substances, dissolved organic matter in water (DOM) and soil organic matter (SOM) in agricultural and forest soils are given to illustrate the potential and limitations of the applied methods. 2) Novel applications of Py-GC/MS and Py-MS in combination with conventional analytical data in an integrated, chemometric approach to investigate the dynamics of plant lipids are reported. This includes multivariate statistical investigations on maturation, senescence, humus genesis, and environmental damages in spruce ecosystems. 3) The focal point is the author`s integrated investigations on emission-induced changes of selected conifer plant constituents. Pattern recognition of Py-MS data of desiccated spruce needles provides a method for distinguishing needles damaged in different ways and determining the cause. Spruce needles were collected from both controls and trees treated with sulphur dioxide (acid rain), nitrogen dioxide, and ozone under controlled conditions. Py-MS and chemometric data evaluation are employed to characterize and classify leaves and their epicuticular waxes. Preliminary mass spectrometric evaluations of isolated cuticles of different plants such as spruce, ivy, holly, and philodendron, as well as ivy cuticles treated in vivo with air pollutants such as surfactants and pesticides are given. (orig.)

  19. New analytical techniques for cuticle chemical analysis

    International Nuclear Information System (INIS)

    Schulten, H.R.

    1994-01-01

    1) The analytical methodology of pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) and direct pyrolysis-mass spectrometry (Py-MS) using soft ionization techniques by high electric fields (FL) are briefly described. Recent advances of Py-GC/MS and Py-FIMS for the analyses of complex organic matter such as plant materials, humic substances, dissolved organic matter in water (DOM) and soil organic matter (SOM) in agricultural and forest soils are given to illustrate the potential and limitations of the applied methods. 2) Novel applications of Py-GC/MS and Py-MS in combination with conventional analytical data in an integrated, chemometric approach to investigate the dynamics of plant lipids are reported. This includes multivariate statistical investigations on maturation, senescence, humus genesis, and environmental damages in spruce ecosystems. 3) The focal point is the author's integrated investigations on emission-induced changes of selected conifer plant constituents. Pattern recognition of Py-MS data of desiccated spruce needles provides a method for distinguishing needles damaged in different ways and determining the cause. Spruce needles were collected from both controls and trees treated with sulphur dioxide (acid rain), nitrogen dioxide, and ozone under controlled conditions. Py-MS and chemometric data evaluation are employed to characterize and classify leaves and their epicuticular waxes. Preliminary mass spectrometric evaluations of isolated cuticles of different plants such as spruce, ivy, holly, and philodendron, as well as ivy cuticles treated in vivo with air pollutants such as surfactants and pesticides are given. (orig.)

  20. Nuclear analytical techniques for nanotoxicology studies

    International Nuclear Information System (INIS)

    Zhang, Z.Y.; Zhao, Y.L.; Chai, Z.F.

    2011-01-01

    With the rapid development of nanotechnology and its applications, a wide variety of nanomaterials are now used in commodities, pharmaceutics, cosmetics, biomedical products, and industries. The potential interactions of nanomaterials with living systems and the environment have attracted increasing attention from the public, as well as from manufacturers of nanomaterial-based products, academic researchers and policymakers. It is important to consider the environmental, health and safety aspects at an early stage of nanomaterial development and application in order to more effectively identify and manage potential human and environmental health impacts from nanomaterial exposure. This will require research in a range of areas, including detection and characterization, environmental fate and transport, ecotoxicology and toxicology. Nuclear analytical techniques (NATs) can play an important role in such studies due to their intrinsic merits such as high sensitivity, good accuracy, high space resolution, ability to distinguish the endogenous or exogenous sources of materials, and ability of in situ and in vivo analysis. In this paper, the applications of NATs in nanotoxicological and nano-ecotoxicological studies are outlined, and some recent results obtained in our laboratory are reported. (orig.)

  1. Application of on-line analytical processing technique in accelerator

    International Nuclear Information System (INIS)

    Xie Dong; Li Weimin; He Duohui; Liu Gongfa; Xuan Ke

    2005-01-01

    A method of application of the on-line analytical processing technique in accelerator is described, which includes data pre-processing, the process of constructing of data warehouse and on-line analytical processing. (authors)

  2. Semi-analytic techniques for calculating bubble wall profiles

    International Nuclear Information System (INIS)

    Akula, Sujeet; Balazs, Csaba; White, Graham A.

    2016-01-01

    We present semi-analytic techniques for finding bubble wall profiles during first order phase transitions with multiple scalar fields. Our method involves reducing the problem to an equation with a single field, finding an approximate analytic solution and perturbing around it. The perturbations can be written in a semi-analytic form. We assert that our technique lacks convergence problems and demonstrate the speed of convergence on an example potential. (orig.)

  3. Analytical Techniques in the Pharmaceutical Sciences

    DEFF Research Database (Denmark)

    Leurs, Ulrike; Mistarz, Ulrik Hvid; Rand, Kasper Dyrberg

    2016-01-01

    Mass spectrometry (MS) offers the capability to identify, characterize and quantify a target molecule in a complex sample matrix and has developed into a premier analytical tool in drug development science. Through specific MS-based workflows including customized sample preparation, coupling to l...

  4. Applying standards to systematize learning analytics in serious games

    NARCIS (Netherlands)

    Serrano-Laguna, Angel; Martinez-Ortiz, Ivan; Haag, Jason; Regan, Damon; Johnson, Andy; Fernandez-Manjon, Baltasar

    2016-01-01

    Learning Analytics is an emerging field focused on analyzing learners’ interactions with educational content. One of the key open issues in learning analytics is the standardization of the data collected. This is a particularly challenging issue in serious games, which generate a diverse range of

  5. Analytical standards for accountability of uranium hexafluoride - 1972

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    An analytical standard for the accountability of uranium hexafluoride is presented that includes procedures for subsampling, determination of uranium, determination of metallic impurities and isotopic analysis by gas and thermal ionization mass spectrometry

  6. Synergistic relationships between Analytical Chemistry and written standards

    International Nuclear Information System (INIS)

    Valcárcel, Miguel; Lucena, Rafael

    2013-01-01

    Graphical abstract: -- Highlights: •Analytical Chemistry is influenced by international written standards. •Different relationships can be established between them. •Synergies can be generated when these standards are conveniently managed. -- Abstract: This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived

  7. Synergistic relationships between Analytical Chemistry and written standards

    Energy Technology Data Exchange (ETDEWEB)

    Valcárcel, Miguel, E-mail: qa1vacam@uco.es; Lucena, Rafael

    2013-07-25

    Graphical abstract: -- Highlights: •Analytical Chemistry is influenced by international written standards. •Different relationships can be established between them. •Synergies can be generated when these standards are conveniently managed. -- Abstract: This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived.

  8. Analytical Techniques and the Air Force Logistics Readiness Officer

    National Research Council Canada - National Science Library

    Main, Bryan D

    2008-01-01

    .... Over 500 LROs and supervisors provided inputs. Analysis of survey responses found that Forecasting, Graphical Statistics, and Descriptive Statistics are the analytical techniques valued most by both LROs and their supervisors...

  9. Analytical Technique of Selection of Constructive Parameters Pneumatichydraulic Springs

    Directory of Open Access Journals (Sweden)

    A. A. Tsipilev

    2014-01-01

    Full Text Available The article "Technique for Analytical Selection of Design Parameters of Pneumatichydraulic Springs concerns the ride smoothness of high-speed vehicles. Author of article Tsipilev A.A. is an assistant at chair "Multi-purpose Tracked Vehicles and Mobile Robots" of BMSTU. The article represents a synthesis of known information on the springing systems and an analysis of relation between spring design data and running gear. It describes standard units of running gear of vehicle in the context of springing systems. Classification of springing systems is considered. Modernization general policy for existing suspensions and prospects for creation of new ones are given. The article considers a design of various pneumatic-hydraulic springs to be set on domestic tracked vehicles. A developed technique allows us to have elastic characteristics of pneumatic-hydraulic springs of various types using these design data and kinematics of the running gear. The article provides recommendations to calculate characteristics of springing systems. The adequacy analysis of the given technique based on the comparison of real and rated characteristics of the existing suspension is conducted. This article can be useful to the experts dealing with springing systems of wheel and tracked vehicles.

  10. Quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cincu, Emanuelathor

    2001-01-01

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  11. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  12. Synthetic salt cake standards for analytical laboratory quality control

    International Nuclear Information System (INIS)

    Schilling, A.E.; Miller, A.G.

    1980-01-01

    The validation of analytical results in the characterization of Hanford Nuclear Defense Waste requires the preparation of synthetic waste for standard reference materials. Two independent synthetic salt cake standards have been prepared to monitor laboratory quality control for the chemical characterization of high-level salt cake and sludge waste in support of Rockwell Hanford Operations' High-Level Waste Management Program. Each synthetic salt cake standard contains 15 characterized chemical species and was subjected to an extensive verification/characterization program in two phases. Phase I consisted of an initial verification of each analyte in salt cake form in order to determine the current analytical capability for chemical analysis. Phase II consisted of a final characterization of those chemical species in solution form where conflicting verification data were observed. The 95 percent confidence interval on the mean for the following analytes within each standard is provided: sodium, nitrate, nitrite, phosphate, carbonate, sulfate, hydroxide, chromate, chloride, fluoride, aluminum, plutonium-239/240, strontium-90, cesium-137, and water

  13. An evaluation of the analytic continuation by duality technique

    CERN Document Server

    Takeuchi, T; Ignjatovic, S R; Wijewardhana, L C R

    1997-01-01

    In Nucl. Phys. B391 (1993) 127, Sundrum and Hsu estimated the value of the oblique correction parameter S for walking technicolor theories using a technique called Analytic Continuation by Duality (ACD). We apply the ACD technique to the perturbative vacuum polarization function and find that it fails to reproduce the well known result S=1/6\\pi. This brings into question the reliability of the ACD technique and the Sundrum and Hsu estimate of S.

  14. Nuclear analytical techniques for recovery of uranium from seawater

    International Nuclear Information System (INIS)

    Prasad, T.L.; Tewari, P.K.; Kalsi, P.C.; Acharya, R.; Manchanda, V.K.

    2010-01-01

    The oceans are virtually limitless reservoir of dissolved uranium in a well defined chemical environment. Various inorganic and organic adsorbents have so far been synthesized and evaluated at laboratory level using synthetic solutions with a view for the recovery of uranium from seawater. With the development of radiation processing technology, special adsorbents are synthesized by radiation grafting of amidoxime groups in the form of leaflets, which provides efficient contact patterns with water body in the sea. Bench scale experiments were initiated to develop process technology. One of the major challenges is to ensure the quality assurance by accurate measurement of heavy metal ion concentrations from lean solutions. In order to address the key issues, nuclear analytical techniques are being developed. Nuclear analytical techniques are based on nuclear properties of the trace level isotopes and have high sensitivity and accuracy and are important tools for chemical analysis. Suitable nuclear radiations (α, β, γ and n) are measured to estimate the concentration of radiation emitting isotope which in turn is used to determine the elemental concentration. In this paper, the application of Nuclear Analytical Techniques is presented. Nuclear Analytical Techniques such as Neutron Activation Analysis (NAA) technique and Solid State Nuclear Track Detection (SSNTD) methods for analyzing the concentrations of heavy metal ions from lean solutions like seawater is presented

  15. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  16. Reference materials for micro-analytical nuclear techniques

    International Nuclear Information System (INIS)

    Valkovic, V.; Zeisler, R.; Bernasconi, G.; Danesi, P.R.

    1994-01-01

    Direct application of many existing reference materials in micro-analytical procedures such as energy dispersive x-ray fluorescence (EDXRF), particle induced x-ray emission spectroscopy (PIXE) and ion probe techniques for the determination of trace elements is often impossible or difficult because: 1) other constituents present in large amounts interfere with the determination; 2) trace components are not sufficiently homogeneously distributed in the sample. Therefore specific natural-matrix reference materials containing very low levels of trace elements and having high degree of homogeneity are required for many micro-analytical procedures. In this report, selection of the types of environmental and biological materials which are suitable for micro-analytical techniques will be discussed. (author)

  17. Recent developments in analytical techniques for characterization of ...

    Indian Academy of Sciences (India)

    With continual decrease of geometries used in modern IC devices, the trace metal impurities of process materials and chemicals used in their manufacture are moving to increasingly lower levels, i.e. ng/g and pg/g levels. An attempt is made to give a brief overview of the use of different analytical techniques in the analysis of ...

  18. Improvement of Analytical Technique for Determination of Gold in ...

    African Journals Online (AJOL)

    This article elucidates the improvement of analytical technique for determination of gold in geological matrix. Samples suspected to have gold in them were subjected to neutron flux from the Nigeria Research Reactor (NRR-1), a Miniature Neutron Source Reactor (MNSR). Two geological samples – one sample was ...

  19. Synergistic relationships between Analytical Chemistry and written standards.

    Science.gov (United States)

    Valcárcel, Miguel; Lucena, Rafael

    2013-07-25

    This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Linear circuit transfer functions an introduction to fast analytical techniques

    CERN Document Server

    Basso, Christophe P

    2016-01-01

    Linear Circuit Transfer Functions: An introduction to Fast Analytical Techniques teaches readers how to determine transfer functions of linear passive and active circuits by applying Fast Analytical Circuits Techniques. Building on their existing knowledge of classical loop/nodal analysis, the book improves and expands their skills to unveil transfer functions in a swift and efficient manner. Starting with simple examples, the author explains step-by-step how expressing circuits time constants in different configurations leads to writing transfer functions in a compact and insightful way. By learning how to organize numerators and denominators in the fastest possible way, readers will speed-up analysis and predict the frequency resp nse of simple to complex circuits. In some cases, they will be able to derive the final expression by inspection, without writing a line of algebra. Key features: * Emphasizes analysis through employing time constant-based methods discussed in other text books but not widely us...

  1. Application of metabonomic analytical techniques in the modernization and toxicology research of traditional Chinese medicine.

    Science.gov (United States)

    Lao, Yong-Min; Jiang, Jian-Guo; Yan, Lu

    2009-08-01

    In the recent years, a wide range of metabonomic analytical techniques are widely used in the modern research of traditional Chinese medicine (TCM). At the same time, the international community has attached increasing importance to TCM toxicity problems. Thus, many studies have been implemented to investigate the toxicity mechanisms of TCM. Among these studies, many metabonomic-based methods have been implemented to facilitate TCM toxicity investigation. At present, the most prevailing methods for TCM toxicity research are mainly single analysis techniques using only one analytical means. These techniques include nuclear magnetic resonance (NMR), gas chromatography-mass spectrometry (GC-MS), and liquid chromatography-mass spectrometry (LC-MS), etc.; with these techniques, some favourable outcomes have been gained in the toxic reaction studies of TCM, such as the action target organs assay, the establishment of action pattern, the elucidation of action mechanism and the exploration of action material foundation. However, every analytical technique has its advantages and drawbacks, no existing analytical technique can be versatile. Multi-analysed techniques can partially overcome the shortcomings of single-analysed techniques. Combination of GC-MS and LC-MS metabolic profiling approaches has unravelled the pathological outcomes of aristolochic acid-induced nephrotoxicity, which can not be achieved by single-analysed techniques. It is believed that with the further development of metabonomic analytical techniques, especially multi-analysed techniques, metabonomics will greatly promote TCM toxicity research and be beneficial to the modernization of TCM in terms of extending the application of modern means in the TCM safety assessment, assisting the formulation of TCM safety norms and establishing the international standards indicators.

  2. Evaluation of analytical techniques to determine matals in Sodium

    International Nuclear Information System (INIS)

    Biancifiori, M.A.; Zappa, G.; Amico, A.

    1985-01-01

    The influence of some instrumental parameters on the analysis of CA, Co, Cr, Cu, Fe, K, Mg, Mn, and Ni in Sodium solutions, by means of Flame Atomic Absorption Spectroscopy (FAAS), is evaluated. The best operating parameters are established and the possibility of application of this analytical technique to the detection of the metallic impurities in Sodium is evaluated, considering the concentration values of nuclear interest

  3. Analytical techniques for wine analysis: An African perspective; a review

    International Nuclear Information System (INIS)

    Villiers, André de; Alberts, Phillipus; Tredoux, Andreas G.J.; Nieuwoudt, Hélène H.

    2012-01-01

    Highlights: ► Analytical techniques developed for grape and wine analysis in Africa are reviewed. ► The utility of infrared spectroscopic methods is demonstrated. ► An overview of separation of wine constituents by GC, HPLC, CE is presented. ► Novel LC and GC sample preparation methods for LC and GC are presented. ► Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  4. Analytical techniques for wine analysis: An African perspective; a review

    Energy Technology Data Exchange (ETDEWEB)

    Villiers, Andre de, E-mail: ajdevill@sun.ac.za [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Alberts, Phillipus [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Tredoux, Andreas G.J.; Nieuwoudt, Helene H. [Institute for Wine Biotechnology, Department of Viticulture and Oenology, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa)

    2012-06-12

    Highlights: Black-Right-Pointing-Pointer Analytical techniques developed for grape and wine analysis in Africa are reviewed. Black-Right-Pointing-Pointer The utility of infrared spectroscopic methods is demonstrated. Black-Right-Pointing-Pointer An overview of separation of wine constituents by GC, HPLC, CE is presented. Black-Right-Pointing-Pointer Novel LC and GC sample preparation methods for LC and GC are presented. Black-Right-Pointing-Pointer Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  5. Transferring an Analytical Technique from Ecology to the Sport Sciences.

    Science.gov (United States)

    Woods, Carl T; Robertson, Sam; Collier, Neil French; Swinbourne, Anne L; Leicht, Anthony S

    2018-03-01

    Learning transfer is defined as an individual's capability to apply prior learnt perceptual, motor, or conceptual skills to a novel task or performance environment. In the sport sciences, learning transfers have been investigated from an athlete-specific perspective. However, sport scientists should also consider the benefits of cross-disciplinary learning to aid critical thinking and metacognitive skill gained through the interaction with similar quantitative scientific disciplines. Using team sports performance analysis as an example, this study aimed to demonstrate the utility of a common analytical technique in ecology in the sports sciences, namely, nonmetric multidimensional scaling. To achieve this aim, three novel research examples using this technique are presented, each of which enables the analysis and visualization of athlete (organism), team (aggregation of organisms), and competition (ecosystem) behaviors. The first example reveals the technical behaviors of Australian Football League Brownlow medalists from the 2001 to 2016 seasons. The second example delineates dissimilarity in higher and lower ranked National Rugby League teams within the 2016 season. Lastly, the third example shows the evolution of game play in the basketball tournaments between the 2004 and 2016 Olympic Games. In addition to the novel findings of each example, the collective results demonstrate that, by embracing cross-disciplinary learning and drawing upon an analytical technique common to ecology, novel solutions to pertinent research questions within sports performance analysis could be addressed in a practically meaningful way. Cross-disciplinary learning may subsequently assist sport scientists in the analysis and visualization of multivariate datasets.

  6. A novel analytical technique suitable for the identification of plastics.

    Science.gov (United States)

    Nečemer, Marijan; Kump, Peter; Sket, Primož; Plavec, Janez; Grdadolnik, Jože; Zvanut, Maja

    2013-01-01

    The enormous development and production of plastic materials in the last century resulted in increasing numbers of such kinds of objects. Development of a simple and fast technique to classify different types of plastics could be used in many activities dealing with plastic materials such as packaging of food, sorting of used plastic materials, and also, if technique would be non-destructive, for conservation of plastic artifacts in museum collections, a relatively new field of interest since 1990. In our previous paper we introduced a non-destructive technique for fast identification of unknown plastics based on EDXRF spectrometry,1 using as a case study some plastic artifacts archived in the Museum in order to show the advantages of the nondestructive identification of plastic material. In order to validate our technique it was necessary to apply for this purpose the comparison of analyses with some of the analytical techniques, which are more suitable and so far rather widely applied in identifying some most common sorts of plastic materials.

  7. Optimization of analytical techniques to characterize antibiotics in aquatic systems

    International Nuclear Information System (INIS)

    Al Mokh, S.

    2013-01-01

    Antibiotics are considered as pollutants when they are present in aquatic ecosystems, ultimate receptacles of anthropogenic substances. These compounds are studied as their persistence in the environment or their effects on natural organisms. Numerous efforts have been made worldwide to assess the environmental quality of different water resources for the survival of aquatic species, but also for human consumption and health risk related. Towards goal, the optimization of analytical techniques for these compounds in aquatic systems remains a necessity. Our objective is to develop extraction and detection methods for 12 molecules of aminoglycosides and colistin in sewage treatment plants and hospitals waters. The lack of analytical methods for analysis of these compounds and the deficiency of studies for their detection in water is the reason for their study. Solid Phase Extraction (SPE) in classic mode (offline) or online followed by Liquid Chromatography analysis coupled with Mass Spectrometry (LC/MS/MS) is the most method commonly used for this type of analysis. The parameters are optimized and validated to ensure the best conditions for the environmental analysis. This technique was applied to real samples of wastewater treatment plants in Bordeaux and Lebanon. (author)

  8. The use of decision analytic techniques in energy policy decisions

    International Nuclear Information System (INIS)

    Haemaelaeinen, R.P.; Seppaelaeinen, T.O.

    1986-08-01

    The report reviews decision analytic techniques and their applications to energy policy decision making. Decision analysis consists in techniques for structuring the essential elements of a decision problem and mathematical methods for ranking the alternatives from a set of simple judgments. Because modeling subjective judgments is characteristic of decision analysis, the models can incorporate qualitative factors and values, which escape traditional energy modeling. Decision analysis has been applied to choices among energy supply alternatives, siting energy facilities, selecting nuclear waste repositories, selecting research and development projects, risk analysis and prioritizing alternative energy futures. Many applications are done in universities and research institutions, but during the 70's the use of decision analysis has spread both to the public and the private sector. The settings where decision analysis has been applied range from aiding a single decision maker to clarifying opposing points of view. Decision analytic methods have also been linked with energy models. The most valuable result of decision analysis is the clarification of the problem at hand. Political decisions cannot be made solely on the basis of models, but models can be used to gain insight of the decision situation. Models inevitably simplify reality, so they must be regarded only as aids to judgment. So far there has been only one decision analysis of energy policy issues in Finland with actual political decision makers as participants. The experiences of this project and numerous foreign applications do however suggest that the decision analytic approach is useful in energy policy questions. The report presents a number of Finnish energy policy decisions where decision analysis might prove useful. However, the applicability of the methods depends crucially on the actual circumstances at hand

  9. ELISA technique standardization for strongyloidiasis diagnosis

    International Nuclear Information System (INIS)

    Huapaya, P.; Espinoza, I.; Huiza, A.; Universidad Nacional Mayor de San Marcos, Lima; Sevilla, C.

    2002-01-01

    To standardize ELISA technique for human Strongyloides stercoralis infection diagnosis a crude antigen was prepared using filariform larvae obtained from positive stool samples cultured with charcoal. Harvested larvae were crushed by sonication and washed by centrifugation in order to obtain protein extracts to be used as antigen. Final protein concentration was 600 μg/mL. Several kinds of ELISA plates were tested and antigen concentration, sera dilution, conjugate dilution and cut off were determined to identify infection. Sera from patients with both hyper-infection syndrome and intestinal infection demonstrated by parasitological examination were positive controls and sera from people living in non-endemic areas with no infection demonstrated by parasitological examination were negative controls. Best values were 5 μg/mL for antigen, 1/64 for sera, 1/1000 for conjugate; optical density values for positive samples were 1,2746 (1,1065 - 1,4206, DS = 0,3284) and for negative samples 0,4457 (0,3324 - 0,5538, DS = 0,2230). Twenty sera samples from positive subjects and one hundred from negative subjects were examined, obtaining 90% sensitivity and 88% specificity. The results show this technique could be useful as strongyloidiasis screening test in population studies

  10. Nuclear Analytical Techniques for Commercial Applications in China

    International Nuclear Information System (INIS)

    Chai, Z.; Zhang, Z.; Feng, S.; Yang, J.; Ouyang, H.; Feng, X.; Mao, X.

    2013-01-01

    Since the establishment of the first Chinese nuclear reactor and accelerator in 1958, the nuclear analytical techniques (NATs) in China have dramatically developed in past half century. Nowadays 10 research nuclear reactors and over 100 small accelerators are available in China. Roughly, about 50 % of the machine time is applied for commercial purpose at the moment. The versatile nuclear analytical methods, mainly NAA, PIXE, XRF, etc., in China have been and are being applied widely and extensively in the following three fields: scientific, training, and commercial. This paper will briefly describe the past experience and present status about NATs for commercial applications. Some practical examples to demonstrate the role of NATs in this aspect will be given as well. Basically, the NATs used for the commercial applications in China can be divided into two types, i.e. off-line and on-line. The former mainly includes instrumental neutron activation analysis (INAA) for compositional determination, particle induced X-ray emission (PIXE) also for compositional analysis, accelerator-based mass-spectrometry (AMS) for analysis of C-14, Be-7, Cl-36 and other long-lived radioactive nuclides, solid state nuclear track detector

  11. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  12. Speciation and Characterization of E-Waste, Using Analytical Techniques

    Science.gov (United States)

    López, C. Cortés; Cruz, V. E. Reyes; Rodríguez, M. A. Veloz; Ávila, J. Hernández; Badillo, J. Flores; Murcia, J. A. Cobos

    Electronic waste (e-waste), have a high potential as a source of precious metals, since they can contain metals like silver, gold, platinum, copper, zinc, nickel, tin and others. In this paper some e-waste were characterized using several analytical techniques as Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and inductively coupled plasma (ICP) in addition to the thermodynamic study by Pourbaix diagrams of silver (Ag), gold (Au), platinum (Pt), copper (Cu), nickel (Ni), tin (Sn) and zinc (Zn); considering an average low concentration of HNO3 (10% v/v). With results of the characterization was determined that the e-waste is an ideal source for the recovery of valuable metals. Similarly, the thermodynamic studies showed that it is possible to obtain all metallic species except Pt, in a potential window of 1.45V to 2.0V vs SCE.

  13. Application of multivariate techniques to analytical data on Aegean ceramics

    International Nuclear Information System (INIS)

    Bieber, A.M.; Brooks, D.W.; Harbottle, G.; Sayre, E.V.

    1976-01-01

    The general problems of data collection and handling for multivariate elemental analyses of ancient pottery are considered including such specific questions as the level of analytical precision required, the number and type of elements to be determined and the need for comprehensive multivariate statistical analysis of the collected data in contrast to element by element statistical analysis. The multivariate statistical procedures of clustering in a multidimensional space and determination of the numerical probabilities of specimens belonging to a group through calculation of the Mahalanobis distances for these specimens in multicomponent space are described together with supporting univariate statistical procedures used at Brookhaven. The application of these techniques to the data on Late Bronze Age Aegean pottery (largely previously analysed at Oxford and Brookhaven with some new specimens considered) have resulted in meaningful subdivisions of previously established groups. (author)

  14. Analytical techniques for thin films treatise on materials science and technology

    CERN Document Server

    Tu, K N

    1988-01-01

    Treatise on Materials Science and Technology, Volume 27: Analytical Techniques for Thin Films covers a set of analytical techniques developed for thin films and interfaces, all based on scattering and excitation phenomena and theories. The book discusses photon beam and X-ray techniques; electron beam techniques; and ion beam techniques. Materials scientists, materials engineers, chemical engineers, and physicists will find the book invaluable.

  15. Nuclear analytical techniques for mineral exploration, mining and processing plants

    International Nuclear Information System (INIS)

    1987-01-01

    This volume is the final report from the Coordinated Research Programme and consists primarily of the research reports presented at the third meeting of the participants. The participants of the meeting considered and discussed progress and achievements made during the last three years: systems for in-stream analysis of mineral slurries, on-line determination of ash in coal using low energy gamma rays transmission and pair production techniques, in-stream determination of solids weight fraction and ash content of coal in slurries, on-line determination of moisture in coal, iron in high grade iron ores and sulfur in lead sinter, developed and tested a borehole logging system based on the spectrometric gamma-gamma method in coal, iron ore and manganese deposits, the results from the NAA and XRF analysis of the tailings and slurries exhibit the potentiality of nuclear analytical techniques in the various stages of the mining industry. A separate abstract was prepared for each of the 12 papers in this volume

  16. Product identification techniques used as training aids for analytical chemists

    Science.gov (United States)

    Grillo, J. P.

    1968-01-01

    Laboratory staff assistants are trained to use data and observations of routine product analyses performed by experienced analytical chemists when analyzing compounds for potential toxic hazards. Commercial products are used as examples in teaching the analytical approach to unknowns.

  17. Meta'omic analytic techniques for studying the intestinal microbiome.

    Science.gov (United States)

    Morgan, Xochitl C; Huttenhower, Curtis

    2014-05-01

    Nucleotide sequencing has become increasingly common and affordable, and is now a vital tool for studies of the human microbiome. Comprehensive microbial community surveys such as MetaHit and the Human Microbiome Project have described the composition and molecular functional profile of the healthy (normal) intestinal microbiome. This knowledge will increase our ability to analyze host and microbial DNA (genome) and RNA (transcriptome) sequences. Bioinformatic and statistical tools then can be used to identify dysbioses that might cause disease, and potential treatments. Analyses that identify perturbations in specific molecules can leverage thousands of culture-based isolate genomes to contextualize culture-independent sequences, or may integrate sequence data with whole-community functional assays such as metaproteomic or metabolomic analyses. We review the state of available systems-level models for studies of the intestinal microbiome, along with analytic techniques and tools that can be used to determine its functional capabilities in healthy and unhealthy individuals. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.

  18. Characterization of pre-hispanic pigments by modern analytical techniques

    International Nuclear Information System (INIS)

    Ortega A, M.

    2003-01-01

    In this work, the study of mural painting pigments from two archaeological sites (The Great Temple in Mexico city and Cacaxtla) was performed to know their materials composition, identify their structural characteristics and properties by using modern analytical techniques. Blue, ochre, red and black pigments of Mexica culture (1325-1521 a.C. / late Post Classic period); blue, ochre, red, brown, pink, green and white of Olmeca- Xicalanca culture (700-900 a.C. / Epiclassic period) were studied. Data about materials used, technological evolution, mineralogical background, cultural interchange and origin was obtained. Environmental exposition of these paintings since their discovering has produced changes and damage on their materials. Therefore, stability of some pigments has been notorious, ''Maya Blue'' specially presents extraordinary resistance to diluted and concentrated acids and alkalis including boiling condition, acqua regia, solvents, oxidant and reducing agents, moderate heat and biocorrosi6n; for that reason its study was emphasized. ''Maya Blue'' pigment was synthesized in laboratory using the processes described by historic sources (with indigophera suffruticosa leaves and synthetic indigo) up to obtain a stable pigment including acqua regia action. Clay matrix sorbs nearly 0.4 weight percent of organic dye, which cover 79% of palygorskita surface area. (Author)

  19. International conference on isotopic and nuclear analytical techniques for health and environment. Unedited papers

    International Nuclear Information System (INIS)

    2004-01-01

    developments in nuclear analytical and radiochemical techniques; - Marine environment and radioecology. The Divisions of Human Health, Physical and Chemical Sciences, and Agency's Laboratories, Seibersdorf under NA Department were responsible for organizing the Conference. The participants appreciated holding an international Conference with such broad scope and presented a number of conclusions and recommendations: 1. The participants acknowledged the continuous support by the IAEA through its Technical Co-operation (TC) and NA Departments for the introduction, maintenance and development of nuclear applications in Member States. They recommended continuing the support with special emphasis on improving quality of results and on training and education of young researchers in nuclear techniques. 2. Support to Member States in adopting international quality standards through the IAEA's TC projects is particularly valuable in enhancing economic competitiveness and in harmonizing analytical information. It was recommended that the IAEA continue these efforts to allow more laboratories to participate in similar QA/QC projects. 3. In view of the broad range of useful applications of nuclear techniques, reflected at this Conference, the participants recommended to the IAEA reinforcement in the promotion of nuclear applications. 4. Beneficial applications in health, environment, research and development, industrial applications, etc. could be strongly advertised to enhance public acceptance of nuclear programmes. 5. Capacity development should be in the core of IAEA's activities in human health, environment, radiochemistry and nuclear chemistry. Particularly support for students should be considered as a means to invest in a sustainable future. 6. The participants proposed that this type of conference be repeated every three to four years

  20. Structural level characterization of base oils using advanced analytical techniques

    KAUST Repository

    Hourani, Nadim

    2015-05-21

    Base oils, blended for finished lubricant formulations, are classified by the American Petroleum Institute into five groups, viz., groups I-V. Groups I-III consist of petroleum based hydrocarbons whereas groups IV and V are made of synthetic polymers. In the present study, five base oil samples belonging to groups I and III were extensively characterized using high performance liquid chromatography (HPLC), comprehensive two-dimensional gas chromatography (GC×GC), and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) equipped with atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) sources. First, the capabilities and limitations of each analytical technique were evaluated, and then the availed information was combined to reveal compositional details on the base oil samples studied. HPLC showed the overwhelming presence of saturated over aromatic compounds in all five base oils. A similar trend was further corroborated using GC×GC, which yielded semiquantitative information on the compound classes present in the samples and provided further details on the carbon number distributions within these classes. In addition to chromatography methods, FT-ICR MS supplemented the compositional information on the base oil samples by resolving the aromatics compounds into alkyl- and naphtheno-subtituted families. APCI proved more effective for the ionization of the highly saturated base oil components compared to APPI. Furthermore, for the detailed information on hydrocarbon molecules FT-ICR MS revealed the presence of saturated and aromatic sulfur species in all base oil samples. The results presented herein offer a unique perspective into the detailed molecular structure of base oils typically used to formulate lubricants. © 2015 American Chemical Society.

  1. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.

    Science.gov (United States)

    Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-01

    An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Video Coding Technique using MPEG Compression Standards ...

    African Journals Online (AJOL)

    Some application areas of video compression focused on the problem of optimizing storage space and transmission bandwidth (BW). The two dimensional discrete cosine transform (2-D DCT) is an integral part of video and image compression, which is used in Moving Picture Expert Group (MPEG) encoding standards.

  3. Contactless conductivity detection for analytical techniques — Developments from 2014 to 2016

    Czech Academy of Sciences Publication Activity Database

    Kubáň, Pavel; Hauser, P.C.

    2017-01-01

    Roč. 38, č. 1 (2017), s. 95-114 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA16-09135S Institutional support: RVO:68081715 Keywords : capacitively coupled contactless conductivity detection * capillary electrophoresis * contactless conductivity detection * analytical techniques * review Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.744, year: 2016

  4. Air pollution in Thailand using nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Leelhaphunt, N.; Chueinta, W.

    1994-01-01

    The methods of neutron activation, both instrumental and radiochemical, and atomic absorption spectrophotometry are used in a study of the concentrations of Al, As, Br, Cd, Cl, Co, Cr, Cu, Fe, Hg, Mn, Sb, Sc, Se, Si, V, Zn and Pb in airborne particulate matter collected from 7 permanent and 9 temporary air quality monitoring stations. The location of the stations are urban residential, suburban residential, mixed (commercial and residential), commercial and industrial areas and near major roads in Bangkok Metropolitan areas. Air sampling is performed once a month for 24 hours continuously using the high volume air sampler (GMW 2000 H) and for 5, 10, and 15 days continuously using an Anderson Air Sampler (SIBATA AN-200). The elements As, Cd and Cu are determined destructively using ion exchange chromatography while Hg and Se are determined by the dry combustion technique. The determination of Pb was done by atomic absorption spectrophotometry. The results of Pb concentrations in airborne particulate matters, collected during 1987 to 1991, were reported by the Office of the National Environment Board. Levels of Pb content were found to be lower than the National Ambient Air Quality Standards. (author). 3 refs, 4 tabs

  5. Applied predictive analytics principles and techniques for the professional data analyst

    CERN Document Server

    Abbott, Dean

    2014-01-01

    Learn the art and science of predictive analytics - techniques that get results Predictive analytics is what translates big data into meaningful, usable business information. Written by a leading expert in the field, this guide examines the science of the underlying algorithms as well as the principles and best practices that govern the art of predictive analytics. It clearly explains the theory behind predictive analytics, teaches the methods, principles, and techniques for conducting predictive analytics projects, and offers tips and tricks that are essential for successful predictive mode

  6. Extended Standard Hough Transform for Analytical Line Recognition

    OpenAIRE

    Abdoulaye SERE; Oumarou SIE; Eric ANDRES

    2013-01-01

    This paper presents a new method which extends the Standard Hough Transform for the recognition of naive or standard line in a noisy picture. The proposed idea conserves the power of the Standard Hough Transform particularly a limited size of the parameter space and the recognition of vertical lines. The dual of a segment, and the dual of a pixel have been proposed to lead to a new definition of the preimage. Many alternatives of approximation could be established for the sinusoid curves of t...

  7. Determination of Rare Earth Elements in Thai Monazite by Inductively Coupled Plasma and Nuclear Analytical techniques

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Ratanapra, Dusadee; Sukharn, Sumalee; Laoharojanaphand, Sirinart

    2003-10-01

    The inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the determination of individual rare-earth elements (REE) was evaluated by comparison with instrumental neutron activation analysis (INAA) and x-ray fluorescence spectrometry (XRF). The accuracy and precision of INAA and ICP-AES were evaluated by using standard reference material IGS-36, a monazite concentrate. For INAA, the results were close to the certified value while ICP-AES were in good agreement except for some low concentration rare earth. The techniques were applied for the analysis of some rare earth elements in two Thai monazite samples preparing as the in-house reference material for the Rare Earth Research and Development Center, Chemistry Division, Office of Atoms for Peace. The analytical results obtained by these techniques were in good agreement with each other

  8. An Accurate Approximate-Analytical Technique for Solving Time-Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    M. Bishehniasar

    2017-01-01

    Full Text Available The demand of many scientific areas for the usage of fractional partial differential equations (FPDEs to explain their real-world systems has been broadly identified. The solutions may portray dynamical behaviors of various particles such as chemicals and cells. The desire of obtaining approximate solutions to treat these equations aims to overcome the mathematical complexity of modeling the relevant phenomena in nature. This research proposes a promising approximate-analytical scheme that is an accurate technique for solving a variety of noninteger partial differential equations (PDEs. The proposed strategy is based on approximating the derivative of fractional-order and reducing the problem to the corresponding partial differential equation (PDE. Afterwards, the approximating PDE is solved by using a separation-variables technique. The method can be simply applied to nonhomogeneous problems and is proficient to diminish the span of computational cost as well as achieving an approximate-analytical solution that is in excellent concurrence with the exact solution of the original problem. In addition and to demonstrate the efficiency of the method, it compares with two finite difference methods including a nonstandard finite difference (NSFD method and standard finite difference (SFD technique, which are popular in the literature for solving engineering problems.

  9. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors...... caused by sample contamination or interference from other elements. The distribution of determinations of Cu in chorion villi from normal pregnant women is used as an example, and after screening it proved to be closely approximated by a logarithmic normal distribution with a mean value of 0.6 mg...

  10. Preparation of standard hair material and development of analytical methodology

    International Nuclear Information System (INIS)

    Gangadharan, S.; Walvekar, A.P.; Ali, M.M.; Thantry, S.S.; Verma, R.; Devi, R.

    1995-01-01

    The concept of the use of human scalp hair as a first level indicator of exposure to inorganic pollutants has been established by us earlier. Efforts towards the preparation of a hair reference material are described. The analytical approaches for the determination of total mercury by cold vapour AAS and INAA and of methylmercury by extraction combined with gas chromatography coupled to an ECD are summarized with results on some of the samples analyzed, including the stability of values over a period of time of storage. (author)

  11. Challenges of Using Learning Analytics Techniques to Support Mobile Learning

    Science.gov (United States)

    Arrigo, Marco; Fulantelli, Giovanni; Taibi, Davide

    2015-01-01

    Evaluation of Mobile Learning remains an open research issue, especially as regards the activities that take place outside the classroom. In this context, Learning Analytics can provide answers, and offer the appropriate tools to enhance Mobile Learning experiences. In this poster we introduce a task-interaction framework, using learning analytics…

  12. Social Data Analytics Using Tensors and Sparse Techniques

    Science.gov (United States)

    Zhang, Miao

    2014-01-01

    The development of internet and mobile technologies is driving an earthshaking social media revolution. They bring the internet world a huge amount of social media content, such as images, videos, comments, etc. Those massive media content and complicate social structures require the analytic expertise to transform those flood of information into…

  13. On numerical-analytic techniques for boundary value problems

    Czech Academy of Sciences Publication Activity Database

    Rontó, András; Rontó, M.; Shchobak, N.

    2012-01-01

    Roč. 12, č. 3 (2012), s. 5-10 ISSN 1335-8243 Institutional support: RVO:67985840 Keywords : numerical-analytic method * periodic successive approximations * Lyapunov-Schmidt method Subject RIV: BA - General Mathematics http://www.degruyter.com/view/j/aeei.2012.12.issue-3/v10198-012-0035-1/v10198-012-0035-1. xml ?format=INT

  14. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  15. Standardizing Physiologic Assessment Data to Enable Big Data Analytics.

    Science.gov (United States)

    Matney, Susan A; Settergren, Theresa Tess; Carrington, Jane M; Richesson, Rachel L; Sheide, Amy; Westra, Bonnie L

    2016-07-18

    Disparate data must be represented in a common format to enable comparison across multiple institutions and facilitate big data science. Nursing assessments represent a rich source of information. However, a lack of agreement regarding essential concepts and standardized terminology prevent their use for big data science in the current state. The purpose of this study was to align a minimum set of physiological nursing assessment data elements with national standardized coding systems. Six institutions shared their 100 most common electronic health record nursing assessment data elements. From these, a set of distinct elements was mapped to nationally recognized Logical Observations Identifiers Names and Codes (LOINC®) and Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT®) standards. We identified 137 observation names (55% new to LOINC), and 348 observation values (20% new to SNOMED CT) organized into 16 panels (72% new LOINC). This reference set can support the exchange of nursing information, facilitate multi-site research, and provide a framework for nursing data analysis. © The Author(s) 2016.

  16. Analytical techniques for the study of polyphenol-protein interactions.

    Science.gov (United States)

    Poklar Ulrih, Nataša

    2017-07-03

    This mini review focuses on advances in biophysical techniques to study polyphenol interactions with proteins. Polyphenols have many beneficial pharmacological properties, as a result of which they have been the subject of intensive studies. The most conventional techniques described here can be divided into three groups: (i) methods used for screening (in-situ methods); (ii) methods used to gain insight into the mechanisms of polyphenol-protein interactions; and (iii) methods used to study protein aggregation and precipitation. All of these methods used to study polyphenol-protein interactions are based on modifications to the physicochemical properties of the polyphenols or proteins after binding/complex formation in solution. To date, numerous review articles have been published in the field of polyphenols. This review will give a brief insight in computational methods and biosensors and cell-based methods, spectroscopic methods including fluorescence emission, UV-vis adsorption, circular dichroism, Fourier transform infrared and mass spectrometry, nuclear magnetic resonance, X-ray diffraction, and light scattering techniques including small-angle X-ray scattering and small-angle neutron scattering, and calorimetric techniques (isothermal titration calorimetry and differential scanning calorimetry), microscopy, the techniques which have been successfully used for polyphenol-protein interactions. At the end the new methods based on single molecule detection with high potential to study polyphenol-protein interactions will be presented. The advantages and disadvantages of each technique will be discussed as well as the thermodynamic, kinetic or structural parameters, which can be obtained. The other relevant biophysical experimental techniques that have proven to be valuable, such electrochemical methods, hydrodynamic techniques and chromatographic techniques will not be described here.

  17. Fluvial sediment transport: Analytical techniques for measuring sediment load

    International Nuclear Information System (INIS)

    2005-07-01

    Sediment transport data are often used for the evaluation of land surface erosion, reservoir sedimentation, ecological habitat quality and coastal sediment budgets. Sediment transport by rivers is usually considered to occur in two major ways: (1) in the flow as a suspended load and (2) along the bed as a bed load. This publication provides guidance on selected techniques for the measurement of particles moving in both modes in the fluvial environment. The relative importance of the transport mode is variable and depends on the hydraulic and sedimentary conditions. The potential user is directed in the selection of an appropriate technique through the presentation of operating principles, application guidelines and estimated costs. Techniques which require laboratory analysis are grab sample, pump sample, depth sample, point integrated and radioactive tracers. Techniques which will continuously record data are optical backscattering, nuclear transmission, single frequency acoustic and laser diffraction

  18. Analytical technique for satellite projected cross-sectional area calculation

    Science.gov (United States)

    Ben-Yaacov, Ohad; Edlerman, Eviatar; Gurfil, Pini

    2015-07-01

    Calculating the projected cross-sectional area (PCSA) of a satellite along a given direction is essential for implementing attitude control modes such as Sun pointing or minimum-drag. The PCSA may also be required for estimating the forces and torques induced by atmospheric drag and solar radiation pressure. This paper develops a new analytical method for calculating the PCSA, the concomitant torques and the satellite exposed surface area, based on the theory of convex polygons. A scheme for approximating the outer surface of any satellite by polygons is developed. Then, a methodology for calculating the projections of the polygons along a given vector is employed. The methodology also accounts for overlaps among projections, and is capable of providing the true PCSA in a computationally-efficient manner. Using the Space Autonomous Mission for Swarming and Geo-locating Nanosatellites mechanical model, it is shown that the new analytical method yields accurate results, which are similar to results obtained from alternative numerical tools.

  19. Structural Analysis of Composite Laminates using Analytical and Numerical Techniques

    Directory of Open Access Journals (Sweden)

    Sanghi Divya

    2016-01-01

    Full Text Available A laminated composite material consists of different layers of matrix and fibres. Its properties can vary a lot with each layer’s or ply’s orientation, material property and the number of layers itself. The present paper focuses on a novel approach of incorporating an analytical method to arrive at a preliminary ply layup order of a composite laminate, which acts as a feeder data for the further detailed analysis done on FEA tools. The equations used in our MATLAB are based on analytical study code and supply results that are remarkably close to the final optimized layup found through extensive FEA analysis with a high probabilistic degree. This reduces significant computing time and saves considerable FEA processing to obtain efficient results quickly. The result output by our method also provides the user with the conditions that predicts the successive failure sequence of the composite plies, a result option which is not even available in popular FEM tools. The predicted results are further verified by testing the laminates in the laboratory and the results are found in good agreement.

  20. Measuring efficiency in health care: analytic techniques and health policy

    National Research Council Canada - National Science Library

    Smith, Peter C; Street, Andrew; Jacobs, Rowena

    2006-01-01

    ... the efficiency of systems and organisations, including data envelopment analysis and stochastic frontier analysis, and also presents some promising new methodological approaches. Such techniques offer the prospect of many new and fruitful insights into health care performance. Nevertheless, they also pose many practical and methodological c...

  1. Applications of nuclear analytical techniques to the Geology

    International Nuclear Information System (INIS)

    Aspiazu F, J.A.; Lopez M, J.; Ramirez T, J.J.; Montero M, E.; Villasenor S, P.

    2001-01-01

    It is applied the PIXE technique for to measure the ratio Sr/Ca in different stages of the stalactite growth. As the ratio depends of the temperature, information about the variations of atmospheric temperature along thousand of years is obtained. (Author)

  2. An Analytical Study of Tools and Techniques for Movie Marketing

    Directory of Open Access Journals (Sweden)

    Garima Maik

    2014-08-01

    Full Text Available Abstract. Bollywood or Hindi movie industry is one of the fastest growing sector in the media and entertainment space creating numerous business and employment opportunities. Movies in India are a major source of entertainment for all sects of society. They not only face competition from other movie industries and movies but from other source of entertainment such as adventure sports, amusement parks, theatre and drama, pubs and discothèques. A lot of man power, man hours, creative brains, and money are put in to build a quality feature film. Bollywood is the industry which continuously works towards providing the 7 billion population with something new always. So it is important for the movie and production team to stand out, to grab the due attention of the maximum audience. Movie makers employ various tools and techniques today to market their movies. They leave no stone unturned. They roll out teasers, First look, Theatrical trailer release, Music launch, City tours, Producer’s and director’s interview, Movie premier, Movie release, post release follow up and etc. to pull the viewers to the Cineplex. The audience today which comprises mainly of youth requires photos, videos, meet ups, gossip, debate, collaboration and content creation. These requirements of today’s generation are most fulfilled through digital platforms. However, the traditional media like newspapers, radio, and television are not old school. They reach out to mass audience and play an upper role in effective marketing. This study aims at analysing these tools for their effectiveness. The objectives are fulfilled through a consumer survey. This study will bring out the effectiveness and relational importance of various tools which are employed by movie marketers to generate maximum returns on the investments by using various data reduction techniques like factor analysis and statistical techniques like chi-square test with data visualization using pie charts

  3. Application of thermo-analytical techniques in nuclear waste management

    International Nuclear Information System (INIS)

    Raje, Naina; Ghonge, Darshana K.; Reddy, A.V.R.

    2015-01-01

    Sodium nitrate solution is the byproduct of nuclear fuel reprocessing plant. It is produced during the neutralization of nitric acid received through purex process and stored in tanks or immobilized in bitumen/cement at site as waste packets. In order to minimize the environmental impact due to these waste packets, it is desirable to reduce nitrate ion to harmless gases like nitrogen. Biodegradation, ion exchange, electrodialysis and chemical treatment are the methods for nitrate reduction in the case of non nuclear industrial waste. Chemical treatment seems to be the most viable process to treat the waste from nuclear reprocessing plant in comparison to the other methods used for the non nuclear industrial waste. During chemical treatment, the nitrate ions can be converted to nitrogen by using a suitable reductant in presence of a catalyst. Formaldehyde has been chosen as the reducing agent for the nitrate - nitrogen conversion and in the process, formaldehyde gets converted to formic acid. In order to optimize the reduction process, it is essential to determine the formaldehyde and formic acid content in the waste feed solution and no direct analytical methodology is available for the same. Present work describes the attempts made to apply evolved gas analysis for understanding the mechanism of conversion of formaldehyde to formic acid. The developed method can be applied for the qualitative/quantitative determination of formaldehyde and formic acid in the waste feed solution. Waste feed samples were received from PSDD, BARC

  4. Using Learning Analytics to Enhance Student Learning in Online Courses Based on Quality Matters Standards

    Science.gov (United States)

    Martin, Florence; Ndoye, Abdou; Wilkins, Patricia

    2016-01-01

    Quality Matters is recognized as a rigorous set of standards that guide the designer or instructor to design quality online courses. We explore how Quality Matters standards guide the identification and analysis of learning analytics data to monitor and improve online learning. Descriptive data were collected for frequency of use, time spent, and…

  5. Chemometric classification techniques as a tool for solving problems in analytical chemistry.

    Science.gov (United States)

    Bevilacqua, Marta; Nescatelli, Riccardo; Bucci, Remo; Magrì, Andrea D; Magrì, Antonio L; Marini, Federico

    2014-01-01

    Supervised pattern recognition (classification) techniques, i.e., the family of chemometric methods whose aim is the prediction of a qualitative response on a set of samples, represent a very important assortment of tools for solving problems in several areas of applied analytical chemistry. This paper describes the theory behind the chemometric classification techniques most frequently used in analytical chemistry together with some examples of their application to real-world problems.

  6. Facility and application of nuclear and supplementary analytical techniques at Dalat Nuclear Research Institute

    International Nuclear Information System (INIS)

    Nguyen Mong Sinh; Ho Manh Dung; Nguyen Thanh Binh

    2006-01-01

    The main applications of the nuclear and supplementary analytical techniques (N and SATs) in the Dalat Nuclear Research Institute (DNRI) and the facilities for the techniques are presented. The NATs in DNRI include the neutron activation analysis (NAA) with instrumental, radiochemical and prompt gamma methods (INAA, RNAA, PGNAA), the X-ray fluorescence analysis (XRFA) and the low-level counting and spectrometry. The sample irradiation sites for NAA, the automatic and manual pneumatic transfer systems, were installed at channels 7-1 and 13-2 and rotary rack on the Dalat research reactor. An ORTEC automatic sample changer (model ASC2) for γ-ray counting was equipped. A computer software for NAA based on the k 0 -standardization method for calculation of elemental concentration was developed. The low-level counting and spectrometry techniques have been setup. The devices required for sampling, sample preparation and data processing have also been equipped. The applications of N and SATs for determination of elemental composition, particularly important in providing data so-called trace elements, radionuclides and multi-element have been enlarged for objects of geology, archaeology, bio-agriculture, health-nutrition and environment. The implementation a quality system for N and SATs has been planned and initiated. (author)

  7. Function of nuclear analytical techniques in Interuniverinteruniversity research cooperation

    International Nuclear Information System (INIS)

    Houtman, J.P.W.

    1977-01-01

    The interuniversity institute was established in 1957 with the instruction to use its major research tool - the nuclear research reactor - in cooperation with and for the benefit of all universities in the Netherlands. Developments in the institute have resulted in two forms of neutron activation analysis currently applied on routine basis. A highly sophisticated automated instrumental multi-element analysis is mostly applied to samples containing elements in the ppm-range and in which no strongly dominating activity is formed. These conditions are fulfilled in general for silicous materials as encountered in geological and archeological samples and in soils and sediments. An automated destructive multi-element analysis involving chemical separations is used for samples with element concentrations in the ppb-range containing some type of dominating activities. This occurs in biological and environmental samples where Na, Fe and Br are mostly available in high concentrations. The institute has been asked many times to help in setting up radio-tracer experiments in various fields including analytical chemistry (isotope dilution, radio immuno assay), physical chemistry (adsorption, diffusion and exchange reactions between solids and liquids during crystallization, corrosion), chemical engineering (determination of contact times and their distribution), biomedical engineering (diffusion processes in membranes for artificial kidneys), biology (uptake of chemical by fish, measurement of displacement habits of animals) etc. Special attention is being paid to the behaviour of trace-elements in metabolic processes, which has been initiated by the medical interest in pathological deviations of copper metabolism in Wilson's and Menkes' diseases. (T.G.)

  8. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  9. Analytical techniques applied to study cultural heritage objects

    International Nuclear Information System (INIS)

    Rizzutto, M.A.; Curado, J.F.; Bernardes, S.; Campos, P.H.O.V.; Kajiya, E.A.M.; Silva, T.F.; Rodrigues, C.L.; Moro, M.; Tabacniks, M.; Added, N.

    2015-01-01

    The scientific study of artistic and cultural heritage objects have been routinely performed in Europe and the United States for decades. In Brazil this research area is growing, mainly through the use of physical and chemical characterization methods. Since 2003 the Group of Applied Physics with Particle Accelerators of the Physics Institute of the University of Sao Paulo (GFAA-IF) has been working with various methodologies for material characterization and analysis of cultural objects. Initially using ion beam analysis performed with Particle Induced X-Ray Emission (PIXE), Rutherford Backscattering (RBS) and recently Ion Beam Induced Luminescence (IBIL), for the determination of the elements and chemical compounds in the surface layers. These techniques are widely used in the Laboratory of Materials Analysis with Ion Beams (LAMFI-USP). Recently, the GFAA expanded the studies to other possibilities of analysis enabled by imaging techniques that coupled with elemental and compositional characterization provide a better understanding on the materials and techniques used in the creative process in the manufacture of objects. The imaging analysis, mainly used to examine and document artistic and cultural heritage objects, are performed through images with visible light, infrared reflectography (IR), fluorescence with ultraviolet radiation (UV), tangential light and digital radiography. Expanding more the possibilities of analysis, new capabilities were added using portable equipment such as Energy Dispersive X-Ray Fluorescence (ED-XRF) and Raman Spectroscopy that can be used for analysis 'in situ' at the museums. The results of these analyzes are providing valuable information on the manufacturing process and have provided new information on objects of different University of Sao Paulo museums. Improving the arsenal of cultural heritage analysis it was recently constructed an 3D robotic stage for the precise positioning of samples in the external beam setup

  10. Advanced analytical techniques: platform for nano materials science

    International Nuclear Information System (INIS)

    Adams, F.; Van Vaeck, L.; Barrett, R.

    2005-01-01

    This paper reviews a range of instrumental microanalytical techniques for their potential in following the development of nanotechnology. Needs for development in secondary ion mass spectrometry (SIMS), transmission electron microscopy (TEM), Auger emission spectrometry (AES) laser mass spectrometry, X-ray photon spectroscopy are discussed as well as synchrotron-based methods for analysis. Objectives for development in all these areas for the coming 5 years are defined. Developments of instrumentation in three European synchrotron installations are given as examples of ongoing development in this field

  11. Analytical techniques applied to study cultural heritage objects

    Energy Technology Data Exchange (ETDEWEB)

    Rizzutto, M.A.; Curado, J.F.; Bernardes, S.; Campos, P.H.O.V.; Kajiya, E.A.M.; Silva, T.F.; Rodrigues, C.L.; Moro, M.; Tabacniks, M.; Added, N., E-mail: rizzutto@if.usp.br [Universidade de Sao Paulo (USP), SP (Brazil). Instituto de Fisica

    2015-07-01

    The scientific study of artistic and cultural heritage objects have been routinely performed in Europe and the United States for decades. In Brazil this research area is growing, mainly through the use of physical and chemical characterization methods. Since 2003 the Group of Applied Physics with Particle Accelerators of the Physics Institute of the University of Sao Paulo (GFAA-IF) has been working with various methodologies for material characterization and analysis of cultural objects. Initially using ion beam analysis performed with Particle Induced X-Ray Emission (PIXE), Rutherford Backscattering (RBS) and recently Ion Beam Induced Luminescence (IBIL), for the determination of the elements and chemical compounds in the surface layers. These techniques are widely used in the Laboratory of Materials Analysis with Ion Beams (LAMFI-USP). Recently, the GFAA expanded the studies to other possibilities of analysis enabled by imaging techniques that coupled with elemental and compositional characterization provide a better understanding on the materials and techniques used in the creative process in the manufacture of objects. The imaging analysis, mainly used to examine and document artistic and cultural heritage objects, are performed through images with visible light, infrared reflectography (IR), fluorescence with ultraviolet radiation (UV), tangential light and digital radiography. Expanding more the possibilities of analysis, new capabilities were added using portable equipment such as Energy Dispersive X-Ray Fluorescence (ED-XRF) and Raman Spectroscopy that can be used for analysis 'in situ' at the museums. The results of these analyzes are providing valuable information on the manufacturing process and have provided new information on objects of different University of Sao Paulo museums. Improving the arsenal of cultural heritage analysis it was recently constructed an 3D robotic stage for the precise positioning of samples in the external beam setup

  12. Real-time analytics techniques to analyze and visualize streaming data

    CERN Document Server

    Ellis, Byron

    2014-01-01

    Construct a robust end-to-end solution for analyzing and visualizing streaming data Real-time analytics is the hottest topic in data analytics today. In Real-Time Analytics: Techniques to Analyze and Visualize Streaming Data, expert Byron Ellis teaches data analysts technologies to build an effective real-time analytics platform. This platform can then be used to make sense of the constantly changing data that is beginning to outpace traditional batch-based analysis platforms. The author is among a very few leading experts in the field. He has a prestigious background in research, development,

  13. Modern trends: analytical chemistry - techniques and application to biodetection

    International Nuclear Information System (INIS)

    Khurshid, S.J.

    1993-01-01

    Microorganism isolated from specimens are usually identified by conventional bacterial identification procedures of morphological evaluation and cultural techniques. These complex methods of studying organisms are extremely tedious and time consuming. This causes serious problems by delaying the decision concerning the presence of pathogens and therefore the adequate drug therapy. Frequently, the decision about the presence of pathogens has to be made prior to the results of microbiological tests. In order to overcome these conditions, workers explored new instrumental methods for characterization, rapid acquisition, high reproducibility, computer aided data recording and interpretation of microorganisms. This article brief reviews application of these modern instrumental approaches such as Infrared Spectroscopy (IR), Gas Chromatography (GC), Fluorescence Spectroscopy, Bioluminescence, Chemiluminescence, FLow Cytometry, Micro calorimetry, GC-MASS Spectrometry, Electrical Impedance, Bio sensors and Radiometry. These techniques have increased the capacity of doing basic research with a major impact on both the clinical laboratories and industry. The radiometric procedure is being used for research and biological quality control of radiopharmaceuticals in our laboratory at PINSTECH. (author)

  14. New analytical techniques to facilitate preformulation screening in propellant systems.

    Science.gov (United States)

    Mogalian, Erik; Kuehl, Philip J; Myrdal, Paul B

    2007-08-01

    The objective of these studies was to investigate the applicability of an online direct inject HPLC method for the preformulation screening of pharmaceutical agents in pressurized metered dose inhalers (MDIs). The technique was initially utilized for the solubility determination of solid solutes. This study explores the extension of the online direct inject method for the evaluation of drug stability in propellant systems as well as for the analysis of MDI vials crimped with metered valves. Through-life content analysis confirmed that a single vial may be repeatedly sampled, thus facilitating the stability evaluation of a single unit over time. The method was successfully used for evaluating the stability of a model drug, as a function of several different formulation configurations, with minimal sample numbers. Additionally, studies determined that after modifications were made to the injection coupler, the technique was also feasible for use with 50 and 100 microL metered valves, however further modifications are necessary for 25 microL valves.

  15. Analytical standards production for the analysis of pomegranate anthocyanins by HPLC

    Directory of Open Access Journals (Sweden)

    Manuela Cristina Pessanha de Araújo Santiago

    2014-03-01

    Full Text Available Pomegranate (Punica granatum L. is a fruit with a long medicinal history, especially due to its phenolic compounds content, such as the anthocyanins, which are reported as one of the most important natural antioxidants. The analysis of the anthocyanins by high performance liquid chromatography (HPLC can be considered as an important tool to evaluate the quality of pomegranate juice. For research laboratories the major challenge in using HPLC for quantitative analyses is the acquisition of high purity analytical standards, since these are expensive and in some cases not even commercially available. The aim of this study was to obtain analytical standards for the qualitative and quantitative analysis of the anthocyanins from pomegranate. Five vegetable matrices (pomegranate flower, jambolan, jabuticaba, blackberry and strawberry fruits were used to isolate each of the six anthocyanins present in pomegranate fruit, using an analytical HPLC scale with non-destructive detection, it being possible to subsequently use them as analytical standards. Furthermore, their identities were confirmed by high resolution mass spectrometry. The proposed procedure showed that it is possible to obtain analytical standards of anthocyanins with a high purity grade (98.0 to 99.9% from natural sources, which was proved to be an economic strategy for the production of standards by laboratories according to their research requirements.

  16. Mapping the Complexities of Online Dialogue: An Analytical Modeling Technique

    Directory of Open Access Journals (Sweden)

    Robert Newell

    2014-03-01

    Full Text Available The e-Dialogue platform was developed in 2001 to explore the potential of using the Internet for engaging diverse groups of people and multiple perspectives in substantive dialogue on sustainability. The system is online, text-based, and serves as a transdisciplinary space for bringing together researchers, practitioners, policy-makers and community leaders. The Newell-Dale Conversation Modeling Technique (NDCMT was designed for in-depth analysis of e-Dialogue conversations and uses empirical methodology to minimize observer bias during analysis of a conversation transcript. NDCMT elucidates emergent ideas, identifies connections between ideas and themes, and provides a coherent synthesis and deeper understanding of the underlying patterns of online conversations. Continual application and improvement of NDCMT can lead to powerful methodologies for empirically analyzing digital discourse and better capture of innovations produced through such discourse. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs140221

  17. Investigation of ceramic devices by analytical electron microscopy techniques

    International Nuclear Information System (INIS)

    Shiojiri, M.; Saijo, H.; Isshiki, T.; Kawasaki, M.; Yoshioka, T.; Sato, S.; Nomura, T.

    1999-01-01

    Ceramics are widely used as capacitors and varistors. Their electrical properties depend on the structure, which is deeply influenced not only by the composition of raw materials and additives but also by heating treatments in the production process. This paper reviews our investigations of SrTiO 3 ceramic devices, which have been performed using various microscopy techniques such as high-resolution transmission electron microscopy (HRTEM), cathodoluminescence scanning electron microscopy (CLSEM), field emission SEM (FE-SEM), energy dispersive X-ray spectroscopy (EDS), electron energy-loss spectroscopy (EELS) and high angle annular dark field (HAADF) imaging method in a FE-(scanning) transmission electron microscope(FE-(S)TEM). (author)

  18. Analytical vs. Simulation Solution Techniques for Pulse Problems in Non-linear Stochastic Dynamics

    DEFF Research Database (Denmark)

    Iwankiewicz, R.; Nielsen, Søren R. K.

    of the problem, i.e. the number of state variables of the dynamical systems. In contrast, the application of the simulation techniques is not limited to Markov problems, nor is it dependent on the mean rate of impulses. Moreover their use is straightforward for a large class of point processes, at least......Advantages and disadvantages of available analytical and simulation techniques for pulse problems in non-linear stochastic dynamics are discussed. First, random pulse problems, both those which do and do not lead to Markov theory, are presented. Next, the analytical and analytically......-numerical techniques suitable for Markov response problems such as moments equation, Petrov-Galerkin and cell-to-cell mapping techniques are briefly discussed. Usefulness of these techniques is limited by the fact that effectiveness of each of them depends on the mean rate of impulses. Another limitation is the size...

  19. ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MELOXICAM IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Aisha Noreen

    2016-06-01

    Full Text Available Meloxicam (MX belongs to the family of oxicams which is the most important group of non steroidal anti-inflammatory drugs (NSAIDs and is widely used for their analgesics and antipyretic activities. It inhibits both COX-I and COX-II enzymes with less gastric and local tissues irritation. A number of analytical techniques have been used for the determination of MX in pharmaceutical as well as in biological fluids. These techniques include titrimetry, spectrometry, chromatography, flow injection spectrometry, fluorescence spectrometry, capillary zone electrophoresis and electrochemical techniques. Many of these techniques have also been used for the simultaneous determination of MX with other compounds. A comprehensive review of these analytical techniques has been done which could be useful for the analytical chemists and quality control pharmacists.

  20. Trends in analytical techniques applied to particulate matter characterization: A critical review of fundaments and applications.

    Science.gov (United States)

    Galvão, Elson Silva; Santos, Jane Meri; Lima, Ana Teresa; Reis, Neyval Costa; Orlando, Marcos Tadeu D'Azeredo; Stuetz, Richard Michael

    2018-05-01

    Epidemiological studies have shown the association of airborne particulate matter (PM) size and chemical composition with health problems affecting the cardiorespiratory and central nervous systems. PM also act as cloud condensation nuclei (CNN) or ice nuclei (IN), taking part in the clouds formation process, and therefore can impact the climate. There are several works using different analytical techniques in PM chemical and physical characterization to supply information to source apportionment models that help environmental agencies to assess damages accountability. Despite the numerous analytical techniques described in the literature available for PM characterization, laboratories are normally limited to the in-house available techniques, which raises the question if a given technique is suitable for the purpose of a specific experimental work. The aim of this work consists of summarizing the main available technologies for PM characterization, serving as a guide for readers to find the most appropriate technique(s) for their investigation. Elemental analysis techniques like atomic spectrometry based and X-ray based techniques, organic and carbonaceous techniques and surface analysis techniques are discussed, illustrating their main features as well as their advantages and drawbacks. We also discuss the trends in analytical techniques used over the last two decades. The choice among all techniques is a function of a number of parameters such as: the relevant particles physical properties, sampling and measuring time, access to available facilities and the costs associated to equipment acquisition, among other considerations. An analytical guide map is presented as a guideline for choosing the most appropriated technique for a given analytical information required. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. New analytical techniques for traffic management on the basis of system studies in logistics

    Directory of Open Access Journals (Sweden)

    Олександр Павлович Кіркін

    2017-07-01

    Full Text Available In today's market conditions, it is necessary for enterprises to constantly maintain their competitiveness. This is achieved through raising customer service standards and use of the latest management techniques. In most cases, enterprises adhere to the logistic principles to optimize production. Over time, however, the development of logistics resulted in emergence of its principal subdivisions: transport, storage, etc. Thus, nowadays there are several parallel methodological developments in the field of logistics and making up logistics chains and systems at different stages of the life cycle of the goods. System research in the field of warehouse logistics showed that the majority of its analytical models of management are based on task conflict. Similar tasks of managing traffic flows in transport logistics are solved by methods of SMO, graph theory, linear programming and differential equations of state etc. These methods are not more accurate than the methods of warehouse logistics, have similar important assumptions and simplifications, and require appropriate mathematical training and knowledge in the field of transport, and sometimes lack visible correlation with economic performance. New analytical techniques for the management of transportation systems based on task conflict will reduce the time and resources for optimization and finding solutions. Methods of warehousing logistics can only be used for the continuous transport quantities (intensity, speed, performance, capacity, execution of works, etc.. In the static condition the search for the optimal service intensity can be found in warehouse logistics. In the study of object in dynamics it is better to use transport approach. Some problems such as supplement of warehouse logistics models with elements of the transport task, are still to be decided

  2. Standardization guide for construction and use of MORT-type analytic trees

    Energy Technology Data Exchange (ETDEWEB)

    Buys, J.R.

    1992-02-01

    Since the introduction of MORT (Management Oversight and Risk Tree) technology as a tool for evaluating the success or failure of safety management systems, there has been a proliferation of analytic trees throughout US Department of Energy (DOE) and its contractor organizations. Standard fault tree'' symbols have generally been used in logic diagram or tree construction, but new or revised symbols have also been adopted by various analysts. Additionally, a variety of numbering systems have been used for event identification. The consequent lack of standardization has caused some difficulties in interpreting the trees and following their logic. This guide seeks to correct this problem by providing a standardized system for construction and use of analytic trees. Future publications of the DOE System Safety Development Center (SSDC) will adhere to this guide. It is recommended that other DOE organizations and contractors also adopt this system to achieve intra-DOE uniformity in analytic tree construction.

  3. Development of analytical techniques of vanadium isotope in seawater

    Science.gov (United States)

    Huang, T.; Owens, J. D.; Sarafian, A.; Sen, I. S.; Huang, K. F.; Blusztajn, J.; Nielsen, S.

    2015-12-01

    value of 0‰. The average yield of 96% further shows that our method is not associated with any loss of V. Preliminary results for un-spiked BATS seawater samples reveal V isotopic compositions close to that of the AA standard. Further analyses of BATS seawater as well as the NASS-6 seawater reference material are in progress.

  4. Political Learning During a Campaign: Micro- and Macro-Analytic Research Techniques.

    Science.gov (United States)

    Graber, Doris A.

    Research techniques for measuring political learning during a campaign are examined. Micro-analytic techniques involve intensive analysis of individuals. Large amounts of data on the psychological and sociological settings of subjects are gathered, along with information on opinions toward past and emerging political situations. Macro-analytic…

  5. Standardization of P-33 by the TDCR efficiency calculation technique

    CSIR Research Space (South Africa)

    Simpson, BRS

    2004-02-01

    Full Text Available and Isotopes 60 (2004) 465?468 The standardization of 33P by the TDCR efficiency calculation technique B.R.S. Simpson*, W.M. Morris Radioactivity Standards Laboratory, CSIR?NML, 15 Lower Hope Road, Rosebank, Cape Town 7700, South Africa Abstract The activity... allowed). 2. Review of the TDCR efficiency calculation technique A LS source is viewed by a three-phototube detection system and the double-tube coincidence counting rate Nd and the triple-tube rate Nt are recorded simulta- neously. If N0 is the 33P...

  6. [How to write an andrological paper: standardization, mechanics and techniques].

    Science.gov (United States)

    Huang, Yu-Feng; Lu, Jin-Chun

    2010-12-01

    Andrological research papers not only reflect the current status and academic level of andrology, but also constitute an important communication platform for researchers and clinicians engaged in this field and contribute significantly to the development of andrology. It would be made easier to write a high-quality andrological paper once the author observes the basic requirements of research papers, adheres to the use of standard scientific terminology, knows the special writing mechanics, and equips himself with some essential writing techniques. Based on the long experience of editorship, we present a detailed introduction of the standardization, mechanics and techniques of writing an andrological paper.

  7. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    Science.gov (United States)

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Solution standards for quality control of nuclear-material analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.

    1981-01-01

    Analytical chemistry measurement control depends upon reliable solution standards. At the Savannah River Plant Control Laboratory over a thousand analytical measurements are made daily for process control, product specification, accountability, and nuclear safety. Large quantities of solution standards are required for a measurement quality control program covering the many different analytical chemistry methods. Savannah River Plant produced uranium, plutonium, neptunium, and americium metals or oxides are dissolved to prepare stock solutions for working or Quality Control Standards (QCS). Because extensive analytical effort is required to characterize or confirm these solutions, they are prepared in large quantities. These stock solutions are diluted and blended with different chemicals and/or each other to synthesize QCS that match the matrices of different process streams. The target uncertainty of a standard's reference value is 10% of the limit of error of the methods used for routine measurements. Standard Reference Materials from NBS are used according to special procedures to calibrate the methods used in measuring the uranium and plutonium standards so traceability can be established. Special precautions are required to minimize the effects of temperature, radiolysis, and evaporation. Standard reference values are periodically corrected to eliminate systematic errors caused by evaporation or decay products. Measurement control is achieved by requiring analysts to analyze a blind QCS each shift a measurement system is used on plant samples. Computer evaluation determines whether or not a measurement is within the +- 3 sigma control limits. Monthly evaluations of the QCS measurements are made to determine current bias correction factors for accountability measurements and detect significant changes in the bias and precision statistics. The evaluations are also used to plan activities for improving the reliability of the analytical chemistry measurements

  9. Paediatric sutureless circumcision-an alternative to the standard technique.

    LENUS (Irish Health Repository)

    2012-01-31

    INTRODUCTION: Circumcision is one of the most commonly performed surgical procedures in male children. A range of surgical techniques exist for this commonly performed procedure. The aim of this study is to assess the safety, functional outcome and cosmetic appearance of a sutureless circumcision technique. METHODS: Over a 9-year period, 502 consecutive primary sutureless circumcisions were performed by a single surgeon. All 502 cases were entered prospectively into a database including all relevant clinical details and a review was performed. The technique used to perform the sutureless circumcision is a modification of the standard sleeve technique with the use of a bipolar diathermy and the application of 2-octyl cyanoacrylate (2-OCA) to approximate the tissue edges. RESULTS: All boys in this study were pre-pubescent and the ages ranged from 6 months to 12 years (mean age 3.5 years). All patients had this procedure performed as a day case and under general anaesthetic. Complications included: haemorrhage (2.2%), haematoma (1.4%), wound infection (4%), allergic reaction (0.2%) and wound dehiscence (0.8%). Only 9 (1.8%) parents or patients were dissatisfied with the cosmetic appearance. CONCLUSION: The use of 2-OCA as a tissue adhesive for sutureless circumcisions is an alternative to the standard suture technique. The use of this tissue adhesive, 2-OCA, results in comparable complication rates to the standard circumcision technique and results in excellent post-operative cosmetic satisfaction.

  10. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. An analytical simulation technique for cone-beam CT and pinhole SPECT

    International Nuclear Information System (INIS)

    Zhang Xuezhu; Qi Yujin

    2011-01-01

    This study was aimed at developing an efficient simulation technique with an ordinary PC. The work involved derivation of mathematical operators, analytic phantom generations, and effective analytical projectors developing for cone-beam CT and pinhole SPECT imaging. The computer simulations based on the analytical projectors were developed by ray-tracing method for cone-beam CT and voxel-driven method for pinhole SPECT of degrading blurring. The 3D Shepp-Logan, Jaszczak and Defrise phantoms were used for simulation evaluations and image reconstructions. The reconstructed phantom images were of good accuracy with the phantoms. The results showed that the analytical simulation technique is an efficient tool for studying cone-beam CT and pinhole SPECT imaging. (authors)

  12. Nanometrology, Standardization and Regulation of Nanomaterials in Brazil: A Proposal for an Analytical-Prospective Model

    Directory of Open Access Journals (Sweden)

    Ana Rusmerg Giménez Ledesma

    2013-05-01

    Full Text Available The main objective of this paper is to propose an analytical-prospective model as a tool to support decision-making processes concerning metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world. In the context of nanotechnology development in Brazil, the motivation for carrying out this research was to identify potential benefits of metrology, standardization and regulation of nanomaterials production, from the perspective of future adoption of the model by the main stakeholders of development of these areas in Brazil. The main results can be summarized as follows: (i an overview of international studies on metrology, standardization and regulation of nanomaterials, and nanoparticles, in special; (ii the analytical-prospective model; and (iii the survey questionnaire and the roadmapping tool for metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world.

  13. Industrial and environmental applications of nuclear analytical techniques. Report of a workshop

    International Nuclear Information System (INIS)

    1999-11-01

    The IAEA has programme the utilisation of nuclear analytical techniques (NATs), in particular for industrial and environmental applications. A major purpose is to help the developing Member States apply their analytical capabilities optimally for socio-economic progress and development. A large number of institutions in Europe, Africa, Latin America and Asia have established X ray fluorescence (XRF) and gamma ray measurement techniques and facilities for neutron activation analysis (NAA) have been initiated in institutions in these regions. Moreover, there is a growing interest among many institutes in applying more advanced analytical techniques, such as particle induced X ray emission (PIXE) and microanalytical techniques based on X ray emission induced by conventional sources or synchrotron radiation to the analysis of environmental and biological materials and industrial products. In order to define new areas of application of NATs and to extend the range of these techniques, a number of initiatives have recently been taken. It includes a workshop on industrial and environmental applications of nuclear analytical techniques, organized by the IAEA in Vienna, 7-11 September 1998. The main objectives of the workshop were as follows: (1) to review recent applications of NATs in industrial and environmental studies; (2) to identify emerging trends in methodologies and applications of NATs; (3) to demonstrate analytical capabilities of selected NATs. The following topics were reviewed during the workshop: (1) XRF and accelerator based analytical techniques; (2) portable XRF systems and their applications in industry, mineral prospecting and processing, (3) portable gamma ray spectrometers; and (4) NAA and its applications in industry and environmental studies. Micro-XRF and micro-PIXE methods and their applications in the above fields were also discussed, including aspects of synchrotron radiation induced X ray emission

  14. A novel wireless modulation technique for inter-standard communications

    NARCIS (Netherlands)

    Bekkaoui, A.; Haartsen, J.C.

    2006-01-01

    A new technique is presented with permits transceivers of different radio standards to communicate with each other. Applications are found in unlicensed bands where radios using different technologies, like for example Bluetooth, ZigBee, or WLAN IEEE 802.11, have to share the same radio spectrum. If

  15. Analytical techniques

    International Nuclear Information System (INIS)

    Alexander, G.V.; McAnulty, L.T.

    1976-01-01

    Optical emission spectroscopy was conducted on 20,000 biological specimens for metallic trace elements. Determinations of 13 C in biological tissues were made by charged particle activation, and carrier-free 123 I was isolated from proton irradiated 124 Te

  16. Regional technical cooperation model project, IAEA - RER/2/2004 ''quality control and quality assurance for nuclear analytical techniques'

    International Nuclear Information System (INIS)

    Arikan, P.

    2002-01-01

    An analytical laboratory should produce high quality analytical data through the use of analytical measurements that is accurate, reliable and adequate for the intended purpose. This objective can be accomplished in a cost-effective manner under a planned and documented quality system of activities. It is well-known that serious deficiencies can occur in laboratory operations when insufficient attention is given to the quality of the work. It requires not only a thorough knowledge of the laboratory's purpose and operation, but also the dedication of the management and operating staff to standards of excellence. Laboratories employing nuclear and nuclear-related analytical techniques are sometimes confronted with performance problems which prevent them from becoming accepted and respected by clients, such as industry, government and regulatory bodies, and from being eligible for contracts. The International Standard ISO 17025 has been produced as the result of extensive experience in the implementation of ISO/IEC Guide 25:1990 and EN 45001:1989, which replaces both of them now. It contains all of the requirements that testing and calibration laboratories must meet if they wish to demonstrate that they operate a quality system that is technically competent, and are able to generate technically valid results. The use of ISO 17025 should facilitate cooperation between laboratories and other bodies to assist in the exchange of information and experience, and in the harmonization of standards and procedures. IAEA model project RER/2/004 entitled 'Quality Assurance/Quality Control in Nuclear Analytical Techniques' was initiated in 1999 as a Regional TC project in East European countries to assist Member State laboratories in the region to install a complete quality system according to the ISO/IEC 17025 standard. 12 laboratories from 11 countries plus the Agency's Laboratories in Seibersdorf have been selected as participants to undergo exercises and training with the

  17. Role of thermo-analytical techniques in compositional characterization of nuclear materials

    International Nuclear Information System (INIS)

    Raje, Naina

    2015-01-01

    The study of heat effects on different materials has a long history. Extraction of metals from the ores, pottery production, glasses making etc. are the examples, where the performance of products obtained from raw materials depends on the processing temperatures. Concrete, pottery, bricks etc., are severely damaged due to uncontrolled high temperatures. Therefore, the heating of raw materials in controlled manner is of pivotal importance to get products of the desired quality. Thermo-analytical techniques provide the information on the effect of heat under controlled heating conditions. In thermo-analytical techniques, physical properties of materials are measured as a function of temperature. Simultaneous thermo-analytical techniques are beneficial in comparison to any single thermo-analytical technique. Simultaneous techniques refer to the measurement of two or more signals on the same sample at the same time in the same instrument. Nowadays, simultaneous thermo-analytical technique are extensively in use for the analysis of materials. Ammonium diuranate (ADU) and magnesium diuranate (MDU), also known as yellowcake, are intermediate precursors in fuel fabrication process, with stringent specifications along with the need to understand its thermal behavior. In the processing of lowgrade ores, higher levels of impurities are being encountered in the leach solution that affects the properties of ADU/MDU. In order to meet the fuel specifications, quality assurance of these nuclear materials is essential. Current studies describe the application of simultaneous Thermogravimetry (TG) - differential thermal analysis (DTA) - evolved gas analysis (EGA) techniques for the compositional characterization of ADU/MDU with respect to the impurities present in the matrices

  18. Development of rocket electrophoresis technique as an analytical tool in preformulation study of tetanus vaccine formulation.

    Science.gov (United States)

    Ahire, V J; Sawant, K K

    2006-08-01

    Rocket Electrophoresis (RE) technique relies on the difference in charges of the antigen and antibodies at the selected pH. The present study involves optimization of RE run conditions for Tetanus Toxoid (TT). Agarose gel (1% w/v, 20 ml, pH 8.6), anti-TT IgG - 1 IU/ml, temperature 4-8 degrees C and run duration of 18 h was found to be optimum. Height of the rocket-shaped precipitate was proportional to TT concentration. The RE method was found to be linear in the concentration range of 2.5 to 30 Lf/mL. The method was validated and found to be accurate, precise, and reproducible when analyzed statistically using student's t-test. RE was used as an analytical method for analyzing TT content in plain and marketed formulations as well as for the preformulation study of vaccine formulation where formulation additives were tested for compatibility with TT. The optimized RE method has several advantages: it uses safe materials, is inexpensive, and easy to perform. RE results are less prone to operator's bias as compared to flocculation test and can be documented by taking photographs and scanned by densitometer; RE can be easily standardized for the required antigen concentration by changing antitoxin concentration. It can be used as a very effective tool for qualitative and quantitative analysis and in preformulation studies of antigens.

  19. Analytical chemistry in semiconductor manufacturing: Techniques, role of nuclear methods and need for quality control

    International Nuclear Information System (INIS)

    1989-06-01

    This report is the result of a consultants meeting held in Gaithersburg, USA, 2-3 October 1987. The meeting was hosted by the National Bureau of Standards and Technology, and it was attended by 18 participants from Denmark, Finland, India, Japan, Norway, People's Republic of China and the USA. The purpose of the meeting was to assess the present status of analytical chemistry in semiconductor manufacturing, the role of nuclear analytical methods and the need for internationally organized quality control of the chemical analysis. The report contains the three presentations in full and a summary report of the discussions. Thus, it gives an overview of the need of analytical chemistry in manufacturing of silicon based devices, the use of nuclear analytical methods, and discusses the need for quality control. Refs, figs and tabs

  20. Field analytical techniques for mercury in soils technology evaluation. Topical report, November 1994--March 1997

    Energy Technology Data Exchange (ETDEWEB)

    Solc, J.; Harju, J.A.; Grisanti, A.A.

    1998-02-01

    This report presents the evaluation of the four field analytical techniques for mercury detection in soils, namely (1) an anodic stripping voltametry technique (ASV) developed and tested by General Electric Corporation; (2) a static headspace analysis (SHSA) technique developed and tested by Dr. Ralph Turner of Oak Ridge National Laboratory; (3) the BiMelyze{reg_sign} Mercury Immunoassay (Bio) developed and tested by BioNebraska, Inc.; and (4) a transportable x-ray fluorescence (XRF) instrument/technique developed and tested by Spectrace, Inc.

  1. Application gives the technique the analytic tree in the evaluation the effectiveness programs to radiological protection

    International Nuclear Information System (INIS)

    Perez Gonzalez, F.; Perez Velazquez, R.S.; Fornet Rodriguez, O.; Mustelier Hechevarria, A.; Miller Clemente, A.

    1998-01-01

    In the work we develop the IAEA recommendations in the application the analytic tree as instrument for the evaluation the effectiveness the occupational radiological protection programs. Is reflected like it has been assimilated and converted that technique in daily work istruments in the evaluation process the security conditions in the institutions that apply the nuclear techniques with a view to its autorization on the part of the regulatory organ

  2. Nuclear analytical techniques for on-line elemental analysis in industry

    International Nuclear Information System (INIS)

    1988-06-01

    This report is the result of an advisory group meeting held in Espoo, Finland, 1-5 June, 1987. The purpose of the meeting was to assess the present status and development of nuclear analytical techniques used for industrial process control. The report gives an overview of the different nuclear techniques used for process control and the most important applications. A separate abstract was prepared for each of the 7 papers presented at the meeting. Refs, figs and tabs

  3. Application of nuclear analytical techniques to investigate trace element content in foodstuffs

    International Nuclear Information System (INIS)

    Gharib, A.

    1985-01-01

    The study performed as a joint project with the IAEA includes those foodstuffs which are being used widely in Iran. It was investigated their nutritional requirements, interrelations and the role of their trace elements in metabolism. Various analytical techniques was assessed and compared. The methods involved in the study were ASS, PIXE and NAA (instrumental and radiochemical)

  4. Critical review of analytical techniques for safeguarding the thorium-uranium fuel cycle

    Energy Technology Data Exchange (ETDEWEB)

    Hakkila, E.A.

    1978-10-01

    Conventional analytical methods applicable to the determination of thorium, uranium, and plutonium in feed, product, and waste streams from reprocessing thorium-based nuclear reactor fuels are reviewed. Separations methods of interest for these analyses are discussed. Recommendations concerning the applicability of various techniques to reprocessing samples are included. 15 tables, 218 references.

  5. Critical review of analytical techniques for safeguarding the thorium-uranium fuel cycle

    International Nuclear Information System (INIS)

    Hakkila, E.A.

    1978-10-01

    Conventional analytical methods applicable to the determination of thorium, uranium, and plutonium in feed, product, and waste streams from reprocessing thorium-based nuclear reactor fuels are reviewed. Separations methods of interest for these analyses are discussed. Recommendations concerning the applicability of various techniques to reprocessing samples are included. 15 tables, 218 references

  6. Analytical and numerical techniques for predicting the interfacial stresses of wavy carbon nanotube/polymer composites

    NARCIS (Netherlands)

    Yazdchi, K.; Salehi, M.; Shokrieh, M.M.

    2009-01-01

    By introducing a new simplified 3D representative volume element for wavy carbon nanotubes, an analytical model is developed to study the stress transfer in single-walled carbon nanotube-reinforced polymer composites. Based on the pull-out modeling technique, the effects of waviness, aspect ratio,

  7. National Cancer Institute Biospecimen Evidence-Based Practices: a novel approach to pre-analytical standardization.

    Science.gov (United States)

    Engel, Kelly B; Vaught, Jim; Moore, Helen M

    2014-04-01

    Variable biospecimen collection, processing, and storage practices may introduce variability in biospecimen quality and analytical results. This risk can be minimized within a facility through the use of standardized procedures; however, analysis of biospecimens from different facilities may be confounded by differences in procedures and inferred biospecimen quality. Thus, a global approach to standardization of biospecimen handling procedures and their validation is needed. Here we present the first in a series of procedural guidelines that were developed and annotated with published findings in the field of human biospecimen science. The series of documents will be known as NCI Biospecimen Evidence-Based Practices, or BEBPs. Pertinent literature was identified via the National Cancer Institute (NCI) Biospecimen Research Database ( brd.nci.nih.gov ) and findings were organized by specific biospecimen pre-analytical factors and analytes of interest (DNA, RNA, protein, morphology). Meta-analysis results were presented as annotated summaries, which highlight concordant and discordant findings and the threshold and magnitude of effects when applicable. The detailed and adaptable format of the document is intended to support the development and execution of evidence-based standard operating procedures (SOPs) for human biospecimen collection, processing, and storage operations.

  8. Determination and identification of synthetic cannabinoids and their metabolites in different matrices by modern analytical techniques – a review

    International Nuclear Information System (INIS)

    Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan; Ondra, Peter; Válka, Ivo; Ševčík, Juraj; Chrastina, Jan; Maier, Vítězslav

    2015-01-01

    Highlights: • Synthetic cannabinoids from analytical point of view. • Determination and identification methods of synthetic cannabinoids in different matrices. • Analytical techniques used from thin layer chromatography to high resolution mass spectrometry. • Detailed survey of gas and liquid chromatography methods for synthetic cannabinoids analysis. - Abstract: Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry

  9. Determination and identification of synthetic cannabinoids and their metabolites in different matrices by modern analytical techniques – a review

    Energy Technology Data Exchange (ETDEWEB)

    Znaleziona, Joanna; Ginterová, Pavlína; Petr, Jan [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic); Ondra, Peter; Válka, Ivo [Department of Forensic Medicine and Medical Law Faculty Hospital, Hněvotínská 3, Olomouc CZ-77146 (Czech Republic); Ševčík, Juraj [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic); Chrastina, Jan [Institute of Special Education Studies, Faculty of Education, Palacký University, Žižkovo náměsti 5, Olomouc CZ-77146 (Czech Republic); Maier, Vítězslav, E-mail: vitezslav.maier@upol.cz [Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, Olomouc CZ-77146 (Czech Republic)

    2015-05-18

    Highlights: • Synthetic cannabinoids from analytical point of view. • Determination and identification methods of synthetic cannabinoids in different matrices. • Analytical techniques used from thin layer chromatography to high resolution mass spectrometry. • Detailed survey of gas and liquid chromatography methods for synthetic cannabinoids analysis. - Abstract: Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger. This review is focused on the sample preparation and the determination of synthetic cannabinoids in different matrices (serum, urine, herbal blends, oral fluid, hair) published since 2004. The review includes separation and identification techniques, such as thin layer chromatography, gas and liquid chromatography and capillary electrophoresis, mostly coupled with mass spectrometry. The review also includes results by spectral methods like infrared spectroscopy, nuclear magnetic resonance or direct-injection mass spectrometry.

  10. Analytic approximate eigenvalues by a new technique. Application to sextic anharmonic potentials

    Science.gov (United States)

    Diaz Almeida, D.; Martin, P.

    2018-03-01

    A new technique to obtain analytic approximant for eigenvalues is presented here by a simultaneous use of power series and asymptotic expansions is presented. The analytic approximation here obtained is like a bridge to both expansions: rational functions, as Padé, are used, combined with elementary functions are used. Improvement to previous methods as multipoint quasirational approximation, MPQA, are also developed. The application of the method is done in detail for the 1-D Schrödinger equation with anharmonic sextic potential of the form V (x) =x2 + λx6 and both ground state and the first excited state of the anharmonic oscillator.

  11. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits. Pt. III

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1982-01-01

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. The techniques may be of interest to hospital radiopharmacy personnel since many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration. Manufacturers of kits may also be interested in learning of the analytical methods used in the assessment of their products

  12. Standardization of surgical techniques used in facial bone contouring.

    Science.gov (United States)

    Lee, Tae Sung

    2015-12-01

    Since the introduction of facial bone contouring surgery for cosmetic purposes, various surgical methods have been used to improve the aesthetics of facial contours. In general, by standardizing the surgical techniques, it is possible to decrease complication rates and achieve more predictable surgical outcomes, thereby increasing patient satisfaction. The technical strategies used by the author to standardize facial bone contouring procedures are introduced here. The author uses various pre-manufactured surgical tools and hardware for facial bone contouring. During a reduction malarplasty or genioplasty procedure, double-bladed reciprocating saws and pre-bent titanium plates customized for the zygomatic body, arch and chin are used. Various guarded oscillating saws are used for mandibular angloplasty. The use of double-bladed saws and pre-bent plates to perform reduction malarplasty reduces the chances of post-operative asymmetry or under- or overcorrection of the zygoma contours due to technical faults. Inferior alveolar nerve injury and post-operative jawline asymmetry or irregularity can be reduced by using a guarded saw during mandibular angloplasty. For genioplasty, final placement of the chin in accordance with preoperative quantitative analysis can be easily performed with pre-bent plates, and a double-bladed saw allows more procedural accuracy during osteotomies. Efforts by the surgeon to avoid unintentional faults are key to achieving satisfactory results and reducing the incidence of complications. The surgical techniques described in this study in conjunction with various in-house surgical tools and modified hardware can be used to standardize techniques to achieve aesthetically gratifying outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Trace element air pollution monitoring studies in Slovenia using nuclear analytical techniques. Appendix 15

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stropnik, B.; Gros, Svetina M.

    1995-01-01

    Up to now, only a few investigations have been performed in Slovenia involving comprehensive studies of trace elements, toxic elements, heavy metals and radionuclides in the atmosphere. The aim of the project is development and application of nuclear and nuclear-related analytical techniques for air pollution studies, leading to formation of a database concerning the trace element air pollution of Slovenia. In this report, the emphasis is on the methodology and analytical development (neutron activation analysis and X-ray spectrometry), and to a lesser extent on the results obtained up to now. Analytical results for several certified reference materials of similar matrix as the real samples investigated are presented and discussed. (author)

  14. A Simplified Analytical Technique for High Frequency Characterization of Resonant Tunneling Diode

    Directory of Open Access Journals (Sweden)

    DESSOUKI, A. A. S.

    2014-11-01

    Full Text Available his paper proposes a simplified analytical technique for high frequency characterization of the resonant tunneling diode (RTD. An equivalent circuit of the RTD that consists of a parallel combination of conductance, G (V, f, and capacitance, C (V, f is formulated. The proposed approach uses the measured DC current versus voltage characteristic of the RTD to extract the equivalent circuit elements parameters in the entire bias range. Using the proposed analytical technique, the frequency response - including the high frequency range - of many characteristic aspects of the RTD is investigated. Also, the maximum oscillation frequency of the RTD is calculated. The results obtained have been compared with those concluded and reported in the literature. The reported results in literature were obtained through simulation of the RTD at high frequency using either a computationally complicated quantum simulator or through difficult RF measurements. A similar pattern of results and highly concordant conclusion are obtained. The proposed analytical technique is simple, correct, and appropriate to investigate the behavior of the RTD at high frequency. In addition, the proposed technique can be easily incorporated into SPICE program to simulate circuits containing RTD.

  15. Experimental evaluation of underride analysis techniques and empirical validation of a new analytical technique.

    Science.gov (United States)

    Boggess, Brian M; Morr, Douglas R; Peterman, Elaine K; Wiechel, John F

    2010-01-01

    Accident reconstructionists are often faced with damage patterns and locations on vehicles that are not well defined by available barrier impact data. One such example is a frontal underride collision. Underride impacts occur when there is a height mismatch between the primary structural components of the impacting vehicles, and the vehicle with the lower height is forced beneath the structure of the other vehicle. The lack of structural engagement typically allows for significantly different damage patterns due to the inherently lower stiffness of the underriding vehicle's contacting surfaces coupled with complex interactions between varying surfaces. In this study, a series of two-vehicle impact tests between a small pickup (bullet vehicle) and a large dump truck (target vehicle) were performed and studied. These tests involved a severe underride configuration in which the dump truck bed's vertical alignment was above the base of the windshield of the pickup. Coupled with these impacting surfaces was a single vertical support, a remnant of a commonly referred to ICC (Interstate Commerce Commission) bumper, which caused a narrow object-type impact, but did not extend down to the pickup's bumper. Multiple prior authors' analytical and empirical relationships to predict impact speed based on crush damage were evaluated using the results of these tests as well as other published underride tests. No single model was sufficient at predicting the mixed mode of impact present in these impact scenarios. However, a system of equations was developed to predict the impact parameters utilizing a combination of previously reported methods and a new empirical relationship presented in this study. This new method shows high correlation and supports the authors' hypothesis that separate crush models can be applied to multiple discrete areas of a vehicle and then combined to form a more complete predictive systematic model.

  16. Multicenter validation of the analytical accuracy of Salmonella PCR: towards an international standard

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Bunge, C.

    2003-01-01

    As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43 Salmo...... and is proposed as an international standard. This study addresses the increasing demand of quality assurance laboratories for standard diagnostic methods and presents findings that can facilitate the international comparison and exchange of epidemiological data.......As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43...... of selectivity by using 364 strains showed that the inclusivity was 99.6% and the exclusivity was 100% for the invA primer set. To indicate possible PCR inhibitors derived from the sample DNA, an internal amplification control (IAC), which was coamplified with the invA target gene, was constructed...

  17. Assessment of analytical techniques for characterization of crystalline clopidogrel forms in patent applications

    Directory of Open Access Journals (Sweden)

    Luiz Marcelo Lira

    2014-04-01

    Full Text Available The aim of this study was to evaluate two important aspects of patent applications of crystalline forms of drugs: (i the physicochemical characterization of the crystalline forms; and (ii the procedure for preparing crystals of the blockbuster drug clopidogrel. To this end, searches were conducted using online patent databases. The results showed that: (i the majority of patent applications for clopidogrel crystalline forms failed to comply with proposed Brazilian Patent Office guidelines. This was primarily due to insufficient number of analytical techniques evaluating the crystalline phase. In addition, some patent applications lacked assessment of chemical/crystallography purity; (ii use of more than two analytical techniques is important; and (iii the crystallization procedure for clopidogrel bisulfate form II were irreproducible based on the procedure given in the patent application.

  18. Standardized fluoroscopy-based technique to measure intraoperative cup anteversion.

    Science.gov (United States)

    Zingg, Matthieu; Boudabbous, Sana; Hannouche, Didier; Montet, Xavier; Boettner, Friedrich

    2017-10-01

    Direct anterior approach (DAA) with the patient lying supine has facilitated the use of intraoperative fluoroscopy and allows for standardized positioning of the patient. The current study presents a new technique to measure acetabular component anteversion using intraoperative fluoroscopy. The current paper describes a mathematical formula to calculate true acetabular component anteversion based on the acetabular component abduction angle and the c-arm tilt angle (CaT). The CaT is determined by tilting the c-arm until an external pelvic oblique radiograph with the equatorial plane of the acetabular component perpendicular to the fluoroscopy receptor is obtained. CaT is determined by direct reading on the C-arm device. The technique was validated using a radiopaque synbone model comparing the described technique to computed tomography anteversion measurement. The experiment was repeated 25 times. The difference in anteversion between the two measuring techniques was on average 0.2° (range -3.0-3.1). The linear regression coefficients evaluating the agreement between the experimental and control methods were 0.99 (95%CI 0.88-1.10, p < 0.001) and 0.33 (95%CI -1.53-2.20, p = 0.713) for the slope and intercept, respectively. The current study confirms that the described three-step c-arm acetabular cup measuring technique can reproducibly and reliably assess acetabular component anteversion in the supine position, as compared to CT-imaging. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2307-2312, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. IAEA progress report I - Study of archeological objects using PIXE analytical technique

    International Nuclear Information System (INIS)

    Roumie, M.

    2005-01-01

    This is the first IAEA progress report for the period 2005-2006 (CRP number F23023). Since 1999 a particle accelerator, located at the Lebanese Atomic Energy Commission in Beirut, has been devoted to elemental analysis in different domains of application: Archeology, Environment and Material Science. It constitutes the first and unique, till now, ion beam analysis facility in Lebanon. Several nuclear analytical techniques are performed, such as PIXE, RBS, PIGE, ERDA and others. (author)

  20. Quantitative determination of the intensities of known components in spectra obtained from surface analytical techniques

    International Nuclear Information System (INIS)

    Nelson, G.C.

    1984-01-01

    Linear least-squares methods have been used to quantitatively decompose experimental data obtained from surface analytical techniques into its separate components. The mathematical procedure for accomplishing this is described and examples are given of the use of this method with data obtained from Auger electron spectroscopy [both N(E) and derivative], x-ray photoelectron spectroscopy, and low energy ion scattering spectroscopy. The requirements on the quality of the data are discussed

  1. Atmospheric Pollution in the Tula Industrial Corridor studied using a biomonitor and nuclear analytical techniques

    OpenAIRE

    M.A. Martínez-Carrillo

    2011-01-01

    This study deals with the application of nuclear analytical techniques to analyze trace elements in the biological monitor Tillandsia usneoides. Biological monitors provides an alternative advantageous way of particulate matter sampling in air pollution studies, since there is no need of special sampling devices, accumulation time can be as long as desired. T. usneoides, which occurs naturally throughout México, was used to monitor air quality of Tula-Vito-Apasco (TVA) industrial corridor at ...

  2. Systematization on survey and analytical technique of the deep stratum environment

    International Nuclear Information System (INIS)

    Sawaragi, Yoshikazu

    2000-08-01

    This research aimed at investigation on survey and analytical technique to efficiently and rationally grasp the stratum environment from surface to depth of the earth and at extraction of survey and analytical technique necessary when newly evaluating the stratum environment of an area. In this fiscal year, systematization of survey and analytical method to effectively and rationally grasp the stratum environment at objects of the wide to local groundwater flows was investigated on a base of research results and programs on the deep stratum which was already performed or is planned in future by the Japan Nuclear Cycle Development Institute. In this report, it was the first step of the systematization to prepare individual research results accumulated before now. And, the individual R and D result in this fiscal year was laid at main body of this report and was a specimen to promote the research in future. Here were reported on evaluation of water permeability of hard non-continuous rock board in the deep stratum, survey and analysis on three-dimensional property of rock board penetrating flow, R and D on hydrologic testing method and apparatus, survey method and modeling at the deep hydrology, survey on geo-chemical property of groundwater, recovery water phenomena of the groundwater, thin/thick salt boundary, and systematization technique. (G.K.)

  3. A Novel Analytical Technique for Optimal Allocation of Capacitors in Radial Distribution Systems

    Directory of Open Access Journals (Sweden)

    Sarfaraz Nawaz

    2017-07-01

    Full Text Available In this paper, a novel analytical technique is proposed to determine the optimal size and location of shunt capacitor units in radial distribution systems. An objective function is formulated to reduce real power loss, to improve the voltage profile and to increase annual cost savings. A new constant, the Loss Sensitivity Constant (LSC, is proposed here. The value of LSC decides the location and size of candidate buses. The technique is demonstrated on an IEEE-33 bus system at different load levels and the 130-bus distribution system of Jamawa Ramgarh village, Jaipur city. The obtained results are compared with the latest optimization techniques to show the effectiveness and robustness of the proposed technique.

  4. Development of gas-phase sample-introduction techniques for analytical atomic spectrometry.

    Science.gov (United States)

    Nakahara, Taketoshi

    2005-05-01

    For the last 30 years, several types of gas-phase sample-introduction methods in analytical atomic spectrometry, i.e., atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) and atomic fluorescence spectrometry (AFS), have been investigated and developed in the author's laboratory. Their fundamental results are summarized in this review article. The gas-phase sample-introduction techniques developed in the author's laboratory can be roughly divided into four groups: i) hydride generation, ii) cold-vapor generation of mercury, iii) analyte volatilization reactions and iv) miscellaneous. The analytical figures of merit of the gas-phase sample-introduction methods have been described in detail. Hydride generation has been coupled with the AAS of As, Bi, Ge, Pb, Sb, Se, Sn and Te, with the inductively coupled plasma (ICP) AES of As, Bi, Sn, Se and Sb, with the high-power nitrogen microwave-induced plasma (N2-MIP) AES of As, Bi, Pb, Sb, Se, Sn and Te by their single- and multi-element determinations, with the AFS of As, Bi, Pb, Sb, Se, Sn and Te, and with the ICP mass spectrometry (MS) of As and Se. The cold-vapor generation method for Hg has been combined with atmospheric-pressure helium microwave-induced plasma (He- or Ar-MIP)-AES and AFS. Furthermore, analyte volatilization reactions have been employed in the ICP-AES of iodine, in the He-MIP-AES of iodine bromine, chlorine, sulfur and carbon, and in the ICP-MS of sulfur. As a result, when compared with conventional solution nebulization, a great improvement in the sensitivity has been attained in each instance. In addition, the developed techniques coupled with analytical atomic spectrometry have been successfully applied to the determination of trace elements in a variety of practical samples.

  5. Synchrotron X-ray Analytical Techniques for Studying Materials Electrochemistry in Rechargeable Batteries.

    Science.gov (United States)

    Lin, Feng; Liu, Yijin; Yu, Xiqian; Cheng, Lei; Singer, Andrej; Shpyrko, Oleg G; Xin, Huolin L; Tamura, Nobumichi; Tian, Chixia; Weng, Tsu-Chien; Yang, Xiao-Qing; Meng, Ying Shirley; Nordlund, Dennis; Yang, Wanli; Doeff, Marca M

    2017-11-08

    Rechargeable battery technologies have ignited major breakthroughs in contemporary society, including but not limited to revolutions in transportation, electronics, and grid energy storage. The remarkable development of rechargeable batteries is largely attributed to in-depth efforts to improve battery electrode and electrolyte materials. There are, however, still intimidating challenges of lower cost, longer cycle and calendar life, higher energy density, and better safety for large scale energy storage and vehicular applications. Further progress with rechargeable batteries may require new chemistries (lithium ion batteries and beyond) and better understanding of materials electrochemistry in the various battery technologies. In the past decade, advancement of battery materials has been complemented by new analytical techniques that are capable of probing battery chemistries at various length and time scales. Synchrotron X-ray techniques stand out as one of the most effective methods that allow for nearly nondestructive probing of materials characteristics such as electronic and geometric structures with various depth sensitivities through spectroscopy, scattering, and imaging capabilities. This article begins with the discussion of various rechargeable batteries and associated important scientific questions in the field, followed by a review of synchrotron X-ray based analytical tools (scattering, spectroscopy, and imaging) and their successful applications (ex situ, in situ, and in operando) in gaining fundamental insights into these scientific questions. Furthermore, electron microscopy and spectroscopy complement the detection length scales of synchrotron X-ray tools and are also discussed toward the end. We highlight the importance of studying battery materials by combining analytical techniques with complementary length sensitivities, such as the combination of X-ray absorption spectroscopy and electron spectroscopy with spatial resolution, because a sole

  6. Creatinine Assay Attainment of Analytical Performance Goals Following Implementation of IDMS Standardization

    Directory of Open Access Journals (Sweden)

    Elizabeth Sunmin Lee

    2017-02-01

    Full Text Available Background: The international initiative to standardize creatinine (Cr assays by tracing reference materials to Isotope Dilution Mass Spectrometry (IDMS assigned values was implemented to reduce interlaboratory variability and improve assay accuracy. Objective: The aims of this study were to examine whether IDMS standardization has improved Cr assay accuracy (bias, interlaboratory variability (precision, total error (TE, and attainment of recommended analytical performance goals. Methods: External Quality Assessment (EQA data (n = 66 challenge vials from Ontario, Canada, were analyzed. The bias, precision, TE, and the number of EQA challenge vials meeting performance goals were determined by assay manufacturer before (n = 32 and after (n = 34 IDMS implementation. Results: The challenge vials with the worst bias and precision were spiked with known common interfering substances (glucose and bilirubin. IDMS standardization improved assay bias (10.4%-1.6%, P < .001, but precision remained unchanged (5.0%-4.7%, P = .5 with performance goals not consistently being met. Precision and TE goals based on biologic variation were attained by only 29% to 69% and 32% to 62% of challenge vials. Conclusions: While IDMS standardization has improved Cr assay accuracy and thus reduced TE, significant interlaboratory variability remains. Contemporary Cr assays do not currently meet the standards required to allow for accurate and consistent estimated glomerular filtration rate assessment and chronic kidney disease diagnosis across laboratories. Further improvements in Cr assay performance are needed.

  7. Process Analytical Techniques Based on In-Line Vibrational Spectroscopy and their Industrial Applications

    Directory of Open Access Journals (Sweden)

    Jednačak, T.

    2013-03-01

    Full Text Available Process analytical techniques (PAT involve the monitoring and control of physical and chemical processes as well as the identification of important process parameters in order to obtain the products with desired properties. PAT have been applied in various industrial process phases to ensure better process understanding, quality by optimal design and determination of process disturbances in time. In-line vibrational spectroscopic techniques are one of the major process analytical techniques used today. The most frequently used in-line vibrational spectroscopic techniques are near infrared spectroscopy (NIR, attenuated total reflectance middle infrared spectroscopy (ATR-MIR and Raman spectroscopy (Table 1, Figs. 1 and 2. They provide in situ real-time monitoring of the production processes by using different types of in-line probes (Figs. 3–5 which reduce exposure to hazardous materials and contamination, sample degradation or equilibrium perturbations in the reaction system. Due to the aforementioned advantages, in-line vibrational spectroscopic techniques have been successfully applied for different industrial pur- poses. The analysis of characteristic vibrational bands in in-line infrared and Raman spectra enable the monitoring of different processes such as crystallization, dissolution, polimorphic transitions and chemical reactions (Scheme 1, Figs. 6 and 7. The obtained data are, due to their complexity, very often further processed by multivariate data analysis methods (Fig. 9, such as principal components analysis (PCA and partial least squares (PLS. The basic principles of PCA and PLS are shown in Fig. 8. A number of different in-line vibrational spectroscopic techniques as well as multivariate data analysis methods have been developed recently, but in this article only the most important and most frequently used techniques are described.   KUI – 7/2013 Received April 10, 2012 Accepted July 18, 2012

  8. A novel analytical approximation technique for highly nonlinear oscillators based on the energy balance method

    Directory of Open Access Journals (Sweden)

    Md. Alal Hosen

    2016-01-01

    Full Text Available In the present paper, a novel analytical approximation technique has been proposed based on the energy balance method (EBM to obtain approximate periodic solutions for the focus generalized highly nonlinear oscillators. The expressions of the natural frequency-amplitude relationship are obtained using a novel analytical way. The accuracy of the proposed method is investigated on three benchmark oscillatory problems, namely, the simple relativistic oscillator, the stretched elastic wire oscillator (with a mass attached to its midpoint and the Duffing-relativistic oscillator. For an initial oscillation amplitude A0 = 100, the maximal relative errors of natural frequency found in three oscillators are 2.1637%, 0.0001% and 1.201%, respectively, which are much lower than the errors found using the existing methods. It is highly remarkable that an excellent accuracy of the approximate natural frequency has been found which is valid for the whole range of large values of oscillation amplitude as compared with the exact ones. Very simple solution procedure and high accuracy that is found in three benchmark problems reveal the novelty, reliability and wider applicability of the proposed analytical approximation technique.

  9. Reef Fish Survey Techniques: Assessing the Potential for Standardizing Methodologies.

    Directory of Open Access Journals (Sweden)

    Zachary R Caldwell

    Full Text Available Dramatic changes in populations of fishes living on coral reefs have been documented globally and, in response, the research community has initiated efforts to assess and monitor reef fish assemblages. A variety of visual census techniques are employed, however results are often incomparable due to differential methodological performance. Although comparability of data may promote improved assessment of fish populations, and thus management of often critically important nearshore fisheries, to date no standardized and agreed-upon survey method has emerged. This study describes the use of methods across the research community and identifies potential drivers of method selection. An online survey was distributed to researchers from academic, governmental, and non-governmental organizations internationally. Although many methods were identified, 89% of survey-based projects employed one of three methods-belt transect, stationary point count, and some variation of the timed swim method. The selection of survey method was independent of the research design (i.e., assessment goal and region of study, but was related to the researcher's home institution. While some researchers expressed willingness to modify their current survey protocols to more standardized protocols (76%, their willingness decreased when methodologies were tied to long-term datasets spanning five or more years. Willingness to modify current methodologies was also less common among academic researchers than resource managers. By understanding both the current application of methods and the reported motivations for method selection, we hope to focus discussions towards increasing the comparability of quantitative reef fish survey data.

  10. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  11. Recent Development in Sample Preparation and Analytical Techniques for Determination of Quinolone Residues in Food Products.

    Science.gov (United States)

    Zhang, Zhichao; Cheng, Hefa

    2017-05-04

    Used heavily in food animal production, quinolones occur widely in food products of animal origin. Development of highly sensitive and selective analytical techniques for the detection of quinolone residues, often at trace levels, in food samples is necessary to ensure food safety and understand their public health risk. With complex matrices, food samples typically require a series of pre-treatment steps, such as powdering, homogenization, deproteinization, and filtration. This review summarizes the recent advances in extraction, concentration, and detection techniques for quinolones in food product samples, and briefly compares the advantages and limitations of major techniques. Recent development of quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction method and immunoassay- and biosensor-based detection methods for the determination of quinolones residues in food products is discussed in details. A perspective on the trends and needs of future research is also presented.

  12. An alternative technique for the implementation of an analytical approximation for transients with temperature feedback

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A.P. [Instituto Federal do Rio de Janeiro, Nilopolis, RJ (Brazil)], e-mail: dpalmaster@gmail.com; Silva, Adilson C. da; Goncalves, Alessandro C.; Martinez, Aquilino S. [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear], e-mail: asilva@con.ufrj.br, e-mail: agoncalves@con.ufrj.br, e-mail: aquilino@lmp.ufrj.br

    2009-07-01

    The analytical solution of point kinetics equations with a group of delayed neutrons is useful in predicting neutron density variation during the operation of a nuclear reactor. Although different approximate solutions for the system of point kinetics equations with temperature feedback may be found in literature, some of them do not present an explicit dependence in time, which makes the computing implementation difficult and, as a result, its applicability in practical cases. The present paper uses the polynomial adjustment technique to overcome this problem in the analytical approximation as proposed by Nahla. In a systematic comparison with other existing approximations it is concluded that the method is adequate, presenting small deviations in relation to the reference values obtained from the reference numerical method. (author)

  13. An alternative technique for the implementation of an analytical approximation for transients with temperature feedback

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Silva, Adilson C. da; Goncalves, Alessandro C.; Martinez, Aquilino S.

    2009-01-01

    The analytical solution of point kinetics equations with a group of delayed neutrons is useful in predicting neutron density variation during the operation of a nuclear reactor. Although different approximate solutions for the system of point kinetics equations with temperature feedback may be found in literature, some of them do not present an explicit dependence in time, which makes the computing implementation difficult and, as a result, its applicability in practical cases. The present paper uses the polynomial adjustment technique to overcome this problem in the analytical approximation as proposed by Nahla. In a systematic comparison with other existing approximations it is concluded that the method is adequate, presenting small deviations in relation to the reference values obtained from the reference numerical method. (author)

  14. Metabolomic analysis using porcine skin: a pilot study of analytical techniques

    OpenAIRE

    Wu, Julie; Fiehn, Oliver; Armstrong, April W

    2014-01-01

    Background: Metabolic byproducts serve as indicators of the chemical processes and can provide valuable information on pathogenesis by measuring the amplified output. Standardized techniques for metabolome extraction of skin samples serve as a critical foundation to this field but have not been developed. Objectives: We sought to determine the optimal cell lysage techniques for skin sample preparation and to compare GC-TOF-MS and UHPLC-QTOF-MS for metabolomic analysis. ...

  15. Radioactive particles in the environment: sources, particle characterization and analytical techniques

    International Nuclear Information System (INIS)

    2011-08-01

    Over the years, radioactive particles have been released to the environment from nuclear weapons testing and nuclear fuel cycle operations. However, measurements of environmental radioactivity and any associated assessments are often based on the average bulk mass or surface concentration, assuming that radionuclides are homogeneously distributed as simple ionic species. It has generally not been recognised that radioactive particles present in the environment often contain a significant fraction of the bulk sample activity, leading to sample heterogeneity problems and false and/or erratic measurement data. Moreover, the inherent differences in the transport and bioavailability of particle bound radionuclides compared with those existing as molecules or ions have largely been ignored in dose assessments. To date, most studies regarding radionuclide behaviour in the soil-plant system have dealt with soluble forms of radionuclides. When radionuclides are deposited in a less mobile form, or in case of a superposition of different physico-chemical forms, the behaviour of radionuclides becomes much more complicated and extra efforts are required to provide information about environmental status and behaviour of radioactive particles. There are currently no documents or international guides covering this aspect of environmental impact assessments. To fill this gap, between 2001 and 2008 the IAEA performed a Coordinated Research Programme (CRP- G4.10.03) on the 'Radiochemical, Chemical and Physical Characterization of Radioactive Particles in the Environment' with the objective of development, adoption and application of standardized analytical techniques for the comprehensive study of radioactive particles. The CRP was in line with the IAEA project intended to assist the Member States in building capacity for improving environmental assessments and for management of sites contaminated with radioactive particles. This IAEA-TECDOC presents the findings and achievements of

  16. Standard Establishment Through Scenarios (SETS): A new technique for occupational fitness standards.

    Science.gov (United States)

    Blacklock, R E; Reilly, T J; Spivock, M; Newton, P S; Olinek, S M

    2015-01-01

    An objective and scientific task analysis provides the basis for establishing legally defensible Physical Employment Standards (PES), based on common and essential occupational tasks. Infrequent performance of these tasks creates challenges when developing PES based on criterion, or content validity. Develop a systematic approach using Subject Matter Experts (SME) to provide tasks with 1) an occupationally relevant scenario considered common to all personnel; 2) a minimum performance standard defined by time, distance, load or work. Examples provided here relate to the development of a new PES for the Canadian Armed Forces (CAF). SME of various experience are selected based on their eligibility criteria. SME are required to define a reasonable scenario for each task from personal experience, provide occupational performance requirements of the scenario in sub-groups, and discuss and agree by consensus vote on the final standard based on the definition of essential. A common and essential task for the CAF is detailed as a case example of process application. Techniques to avoid common SME rating errors are discussed and advantages to the method described. The SETS method was developed as a systematic approach to setting occupational performance standards and qualifying information from SME.

  17. Technique and Understanding: Paul Ricoeur on Freud and the Analytic Experience

    Directory of Open Access Journals (Sweden)

    Eoin Carney

    2016-08-01

    Full Text Available For Ricœur any study of Freud, or of psychoanalysis more generally, needs to take into account the crucial dimension of the analytic experience itself. Psychoanalysis, as a “mixed discourse,” aims to anticipate questions of meaning and explication alongside technical questions of energies, repression, displacement, and so on. The analytic experience is one which is practical and intersubjective, but which is also guided by various techniques or methods. These techniques, I will argue, should be understood as a type of techne, one which is less concerned with hermeneutic questions of meaning than with quasi-scientific questions of force, feedback, struggle, and process. The practice of psychoanalysis, on the other hand, deals with the ways in which these forces or drives become meaningful for a particular subject, and within a singular context or history. This article will aim to draw out both the interrelationship between techniques and practical understanding, and also the productive incommensurability between the two.

  18. Applied research on air pollution using nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    1994-01-01

    A co-ordinated research programme (CRP) on applied research on air pollution using nuclear-related techniques is a global CRP which will run from 1992-1996, and will build upon the experience gained by the Agency from the laboratory support that it has been providing for several years to BAPMoN - the Background Air Pollution Monitoring Network programme organized under the auspices of the World Meterological Organization. The purpose of this CRP is to promote the use of nuclear analytical techniques in air pollution studies, e.g. NAA, XFR, and PIXE for the analysis of toxic and other trace elements in suspended particulate matter (including air filter samples), rainwater and fog-water samples, and in biological indicators of air pollution (e.g. lichens and mosses). The main purposes of the core programme are i) to support the use of nuclear and nuclear-related analytical techniques for practically-oriented research and monitoring studies on air pollution ii) to identify major sources of air pollution affecting each of the participating countries with particular reference to toxic heavy metals, and iii) to obtain comparative data on pollution levels in areas of high pollution (e.g. a city centre or a populated area downwind of a large pollution source) and low pollution (e.g. rural areas). This document reports the discussions held during the first Research Co-ordination Meeting (RCM) for the CRP which took place at the IAEA Headquarters in Vienna. Refs, figs and tabs

  19. Technical meeting on commercial applications of nuclear analytical techniques. Meeting report

    International Nuclear Information System (INIS)

    2004-01-01

    This report summarizes the findings of the Technical Meeting on the Commercial Applications of Nuclear Analytical Techniques held in Vienna on 23-26 November 2004, where an assessment was initiated of the world capacity and market potentials for neutron activation analysis and nuclear spectroscopy, including an estimation of economic revenues. Industry and governmental agencies were identified as stakeholders for these laboratories. Examples are given of potential benefits of these techniques to the stakeholders. The potentials for commercial applications of neutron activation analysis and nuclear spectroscopy (measurement of alpha, beta and gamma ray emitting radionuclides) are addressed. First estimates are given of the worldwide capacity of these laboratories, suggestions and examples are given for potential markets and the typical organizational and technical constraints are discussed. Two case studies of commercial neutron activation analysis laboratories at a small and a medium-size reactor are given in the 'individual contributions' section of this document. An assessment of other nuclear analytical techniques such as X ray Fluorescence Spectrometry, Particle Induced X ray Emission Spectrometry or Ion Beam Analysis Spectrometry has been completed after a comprehensive collection of background information

  20. Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation

    Directory of Open Access Journals (Sweden)

    Abuzar Kabir

    2017-12-01

    Full Text Available Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment and post-treatment steps; reducing the sample volume requirement; reducing extraction equilibrium time, maximizing extraction efficiency etc. All these improved attributes are congruent with the Green Analytical Chemistry (GAC principles. Classical sample preparation techniques such as solid phase extraction (SPE and liquid-liquid extraction (LLE are being rapidly replaced with emerging miniaturized and environmentally friendly techniques such as Solid Phase Micro Extraction (SPME, Stir bar Sorptive Extraction (SBSE, Micro Extraction by Packed Sorbent (MEPS, Fabric Phase Sorptive Extraction (FPSE, and Dispersive Liquid-Liquid Micro Extraction (DLLME. In addition to the development of many new generic extraction sorbents in recent years, a large number of molecularly imprinted polymers (MIPs created using different template molecules have also enriched the large cache of microextraction sorbents. Application of nanoparticles as high-performance extraction sorbents has undoubtedly elevated the extraction efficiency and method sensitivity of modern chromatographic analyses to a new level. Combining magnetic nanoparticles with many microextraction sorbents has opened up new possibilities to extract target analytes from sample matrices containing high volumes of matrix interferents. The aim of the current review is to critically audit the progress of microextraction techniques in recent years, which has indisputably transformed the analytical chemistry practices, from biological and therapeutic drug monitoring to the environmental field; from foods to phyto

  1. Commissioning of the laboratory of Atucha II NPP. Implementation and optimization of analytical techniques, quality aspects

    International Nuclear Information System (INIS)

    Schoenbrod, Betina; Quispe, Benjamin; Cattaneo, Alberto; Rodriguez, Ivanna; Chocron, Mauricio; Farias, Silvia

    2012-09-01

    Atucha II NPP is a Pressurized Vessel Heavy Water Reactor (PVHWR) of 740 MWe designed by SIEMENSKWU. After some years of delay, this NPP is in advanced construction state, being the beginning of commercial operation expected for 2013. Nucleoelectrica Argentina (N.A.S.A.) is the company in charge of the finalization of this project and the future operation of the plant. The Comision Nacional de Energia Atomica (C.N.E.A.) is the R and D nuclear institution in the country that, among many other topics, provides technical support to the stations. The Commissioning Chemistry Division of CNAII is in charge of the commissioning of the demineralization water plant and the organization of the chemical laboratory. The water plant started operating successfully in July 2010 and is providing the plant with nuclear grade purity water. Currently, in the conventional ('cold') laboratory several activities are taking place. On one hand, analytical techniques for the future operation of the plant are being tested and optimized. On the other hand, the laboratory is participating in the cleaning and conservation of the different components of the plant, providing technical support and the necessary analysis. To define the analytical techniques for the normal operation of the plant, the parameters to be measured and their range were established in the Chemistry Manual. The necessary equipment and reagents were bought. In this work, a summary of the analytical techniques that are being implemented and optimized is presented. Common anions (chloride, sulfate, fluoride, bromide and nitrate) are analyzed by ion chromatography. Cations, mainly sodium, are determined by absorption spectrometry. A UV-Vis spectrometer is used to determine silicates, iron, ammonia, DQO, total solids, true color and turbidity. TOC measurements are performed with a TOC analyzer. To optimize the methods, several parameters are evaluated: linearity, detection and quantification limits, precision and

  2. Wireless network development for the automatic registration of parameters in laboratories of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Tincopa, Jean Pierre; Baltuano, Oscar; Bedregal, Patricia

    2015-01-01

    This paper presents in detail the development of a low-cost wireless network for automatic recording of temperature and relative humidity parameters in the laboratory of nuclear analytical techniques. This prototype has a DHT22 sensor which gives us both parameters with high precision and are automatically read and displayed by a ATmega328P microcontroller. This data is then transmitted through transceivers Xbee Pro S2B forming a mesh network for real time storage using an RTC (Real Time Clock). We present the experimental results obtained in its implementation. (author)

  3. Teaching Writing Analytical Exposition Text by Using Team Word-webbing Technique

    OpenAIRE

    Yudianto, Fajar

    2017-01-01

    The purpose of this research was to investigate whether or not the use of “Team Word-Webbing Technique” effective in teaching writing analytical exposition text at the eleventh grade students of SMAN 1 Sungai Ambawang in academic year 2016/2017. This research applied a quasi-experimental design. The population of this research was XI IPA 2 as the experimental group and XI IPA 1 as the control group. The data was collected by using measurement technique with written test as the tool of collect...

  4. General technique for analytical derivatives of post-projected Hartree-Fock.

    Science.gov (United States)

    Tsuchimochi, Takashi; Ten-No, Seiichiro

    2017-02-21

    In electronic structure theory, the availability of an analytical derivative is one of the desired features for a method to be useful in practical applications, as it allows for geometry optimization as well as computation of molecular properties. With the recent advances in the development of symmetry-projected Hartree-Fock (PHF) methods, we here aim at further extensions by devising the analytic gradients of post-PHF approaches with a special focus on spin-extended (spin-projected) configuration interaction with single and double substitutions (ECISD). Just like standard single-reference methods, the mean-field PHF part does not require the corresponding coupled-perturbed equation to be solved, while the correlation energy term needs the orbital relaxation effect to be accounted for, unless the underlying molecular orbitals are variationally optimized in the presence of the correlation energy. We present a general strategy for post-PHF analytical gradients, which closely parallels that for single-reference methods, yet addressing the major difference between them. The similarity between ECISD and multi-reference CI not only in the energy but also in the optimized geometry is clearly demonstrated by the numerical examples of ozone and cyclobutadiene.

  5. Analytical thermal study on nonlinear fundamental heat transfer cases using a novel computational technique

    International Nuclear Information System (INIS)

    Ghasemi, Seiyed E.; Zolfagharian, Ali; Hatami, M.; Ganji, D.D.

    2016-01-01

    Highlights: • Fin temperature distribution with a temperature-dependent thermal conductivity is investigated. • Cooling of the lumped system with a variable specific heat is studied analytically. • Temperature distribution of a convective–radiative fin with a constant thermal conductivity is analyzed. - Abstract: In this paper a novel computational technique called Parameterized Perturbation Method (PPM) is used to obtain the solutions of nonlinear fundamental heat conduction equations. Three well known problems in the area of heat transfer are addressed to be solved. An analytical investigation is carried out for: (a) the temperature distribution in a fin with a temperature-dependent thermal conductivity, (b) the cooling of the lumped system with variable specific heat, and (c) the temperature distribution of a convective–radiative fin. The validity of the results of PPM solution was verified via comparison with numerical results obtained using a fourth order Runge–Kutta method. These comparisons revealed that PPM is a powerful approach for solving these problems. Also, the results showed that the main attributions of this method are very straightforward calculations and low computational burden compared to previous analytical and numerical approaches.

  6. Determination of perfluorinated compounds in human plasma and serum standard reference materials using independent analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Jessica L. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Phinney, Karen W. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States)

    2011-11-15

    Perfluorinated compounds (PFCs) were measured in three National Institute of Standards and Technology (NIST) Standard Reference Materials (SRMs) (SRMs 1950 Metabolites in Human Plasma, SRM 1957 Organic Contaminants in Non-fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum) using two analytical approaches. The methods offer some independence, with two extraction types and two liquid chromatographic separation methods. The first extraction method investigated the acidification of the sample followed by solid-phase extraction (SPE) using a weak anion exchange cartridge. The second method used an acetonitrile extraction followed by SPE using a graphitized non-porous carbon cartridge. The extracts were separated using a reversed-phase C{sub 8} stationary phase and a pentafluorophenyl (PFP) stationary phase. Measured values from both methods for the two human serum SRMs, 1957 and 1958, agreed with reference values on the Certificates of Analysis. Perfluorooctane sulfonate (PFOS) values were obtained for the first time in human plasma SRM 1950 with good reproducibility among the methods (below 5% relative standard deviation). The nominal mass interference from taurodeoxycholic acid, which has caused over estimation of the amount of PFOS in biological samples, was separated from PFOS using the PFP stationary phase. Other PFCs were also detected in SRM 1950 and are reported. SRM 1950 can be used as a control material for human biomonitoring studies and as an aid to develop new measurement methods. (orig.)

  7. NET European Network on Neutron Techniques Standardization for Structural Integrity

    International Nuclear Information System (INIS)

    Youtsos, A.

    2004-01-01

    Improved performance and safety of European energy production systems is essential for providing safe, clean and inexpensive electricity to the citizens of the enlarged EU. The state of the art in assessing internal stresses, micro-structure and defects in welded nuclear components -as well as their evolution due to complex thermo-mechanical loads and irradiation exposure -needs to be improved before relevant structural integrity assessment code requirements can safely become less conservative. This is valid for both experimental characterization techniques and predictive numerical algorithms. In the course of the last two decades neutron methods have proven to be excellent means for providing valuable information required in structural integrity assessment of advanced engineering applications. However, the European industry is hampered from broadly using neutron research due to lack of harmonised and standardized testing methods. 35 European major industrial and research/academic organizations have joined forces, under JRC coordination, to launch the NET European Network on Neutron Techniques Standardization for Structural Integrity in May 2002. The NET collaborative research initiative aims at further development and harmonisation of neutron scattering methods, in support of structural integrity assessment. This is pursued through a number of testing round robin campaigns on neutron diffraction and small angle neutron scattering - SANS and supported by data provided by other more conventional destructive and non-destructive methods, such as X-ray diffraction and deep and surface hole drilling. NET also strives to develop more reliable and harmonized simulation procedures for the prediction of residual stress and damage in steel welded power plant components. This is pursued through a number of computational round robin campaigns based on advanced FEM techniques, and on reliable data obtained by such novel and harmonized experimental methods. The final goal of

  8. Intracavity optogalvanic spectroscopy. An analytical technique for 14C analysis with subattomole sensitivity.

    Science.gov (United States)

    Murnick, Daniel E; Dogru, Ozgur; Ilkmen, Erhan

    2008-07-01

    We show a new ultrasensitive laser-based analytical technique, intracavity optogalvanic spectroscopy, allowing extremely high sensitivity for detection of (14)C-labeled carbon dioxide. Capable of replacing large accelerator mass spectrometers, the technique quantifies attomoles of (14)C in submicrogram samples. Based on the specificity of narrow laser resonances coupled with the sensitivity provided by standing waves in an optical cavity and detection via impedance variations, limits of detection near 10(-15) (14)C/(12)C ratios are obtained. Using a 15-W (14)CO2 laser, a linear calibration with samples from 10(-15) to >1.5 x 10(-12) in (14)C/(12)C ratios, as determined by accelerator mass spectrometry, is demonstrated. Possible applications include microdosing studies in drug development, individualized subtherapeutic tests of drug metabolism, carbon dating and real time monitoring of atmospheric radiocarbon. The method can also be applied to detection of other trace entities.

  9. Experiences with IAEA project: TC Regional Project on Quality Control and Quality Assurance for Nuclear Analytical Techniques (RER/2/004)

    International Nuclear Information System (INIS)

    Glavic-Cindro, Denis; Korun, Matjaz

    2002-01-01

    In the TC Regional Project on Quality Control and Quality Assurance for Nuclear Analytical Techniques RER/2/004, 12 laboratories from east and central European countries participated. Within this project 4 workshops, 2 audit inspections and 2 proficiency tests were organized. The aim of this project was to help these laboratories to implement quality assurance system based on the ISO 17025 standard and to help them on the way towards accreditation. (author)

  10. In Situ Analytical Characterization of Contaminated Sites Using Nuclear Spectrometry Techniques. Review of Methodologies and Measurements

    International Nuclear Information System (INIS)

    2017-01-01

    Past and current human activities can result in the contamination of sites by radionuclides and heavy metals. The sources of contamination are various. The most important sources for radionuclide release include global fallout from nuclear testing, nuclear and radiological accidents, waste production from nuclear facilities, and activities involving naturally occurring radioactive material (NORM). Contamination of the environment by heavy metals mainly originates from industrial applications and mineralogical background concentration. Contamination of sites by radionuclides and heavy metals can present a risk to people and the environment. Therefore, the estimation of the contamination level and the identification of the source constitute important information for the national authorities with the responsibility to protect people and the environment from adverse health effects. In situ analytical techniques based on nuclear spectrometry are important tools for the characterization of contaminated sites. Much progress has been made in the design and implementation of portable systems for efficient and effective monitoring of radioactivity and heavy metals in the environment directly on-site. Accordingly, the IAEA organized a Technical Meeting to review the current status and trends of various applications of in situ nuclear spectrometry techniques for analytical characterization of contaminated sites and to support Member States in their national environmental monitoring programmes applying portable instrumentation. This publication represents a comprehensive review of the in situ gamma ray spectrometry and field portable X ray fluorescence analysis techniques for the characterization of contaminated sites. It includes papers on the use of these techniques, which provide useful background information for conducting similar studies, in the following Member States: Argentina, Australia, Brazil, Czech Republic, Egypt, France, Greece, Hungary, Italy, Lithuania

  11. From basic survival analytic theory to a non-standard application

    CERN Document Server

    Zimmermann, Georg

    2017-01-01

    Georg Zimmermann provides a mathematically rigorous treatment of basic survival analytic methods. His emphasis is also placed on various questions and problems, especially with regard to life expectancy calculations arising from a particular real-life dataset on patients with epilepsy. The author shows both the step-by-step analyses of that dataset and the theory the analyses are based on. He demonstrates that one may face serious and sometimes unexpected problems, even when conducting very basic analyses. Moreover, the reader learns that a practically relevant research question may look rather simple at first sight. Nevertheless, compared to standard textbooks, a more detailed account of the theory underlying life expectancy calculations is needed in order to provide a mathematically rigorous framework. Contents Regression Models for Survival Data Model Checking Procedures Life Expectancy Target Groups Researchers, lecturers, and students in the fields of mathematics and statistics Academics and experts work...

  12. Analytical model for Transient Current Technique (TCT) signal prediction and analysis for thin interface characterization

    Science.gov (United States)

    Bronuzzi, J.; Mapelli, A.; Sallese, J. M.

    2016-12-01

    A silicon wafer bonding technique has been recently proposed for the fabrication of monolithic silicon radiation detectors. This new process would enable direct bonding of a read-out electronic chip wafer on a highly resistive silicon substrate wafer. Therefore, monolithic silicon detectors could be fabricated in this way which would allow the free choice of electronic chips and high resistive silicon bulk, even from different providers. Moreover, a monolithic detector with a high resistive bulk would also be available. Electrical properties of the bonded interface are then critical for this application. Indeed, mobile charges generated by radiation inside the bonded bulk are expected to transit through the interface to be collected by the read-out electronics. In order to characterize this interface, the concept of Transient Current Technique (TCT) has been explored by means of numerical simulations combined with a physics based analytical model. In this work, the analytical model giving insight into the physics behind the TCT dependence upon interface traps is validated using both TCAD simulations and experimental measurements.

  13. Impact of accelerator-based analytical techniques on the knowledge and conservation of cultural heritage

    International Nuclear Information System (INIS)

    Dran, Jean Claude

    2001-01-01

    A large set of modern analytical techniques is currently applied to get a better insight on art and archaeological objects as well as to contribute to their conservation and restoration. Because of the precious and sometimes unique character of the works, non-destructive techniques and even those requiring no (or only minute) sampling, are preferred. From this standpoint, ion beam analysis (IBA) constitutes one of the best choices, since it combines quite good analytical performance and non-destructiveness. For over 10 years, an IBA facility has been installed in the Research Laboratory of the Museums of France. Until now it is the only facility of this kind entirely devoted to the study of cultural heritage. A special set-up, namely an external beam line, has been developed which permits the in-air analysis of large or fragile works of art without sampling. This facility is used for both short investigations at the request of museum curators and extensive research works in art history and archaeology. Numerous examples will be given to highlight the impact of this tool on cultural heritage. (author)

  14. Contribution of analytical techniques coupled to the knowledge of the uranium speciation in natural conditions

    International Nuclear Information System (INIS)

    Petit, J.

    2009-06-01

    To understand the transport mechanisms and the radionuclides behaviour in the bio-geosphere is necessary to evaluate healthy and environmental risks of nuclear industry. These mechanisms are monitored by radioelements speciation, namely the distribution between their different physico-chemical forms in the environment. From this perspective, this PhD thesis deals with uranium speciation in a natural background. A detailed summary of uranium biogeochemistry has been written, which enables to restrict the PhD issue to uranium complexation with oxalic acid, a hydrophilic organic acid with good binding properties, ubiquitous in soil waters. Analytical conditions have been established by means of speciation diagrams. The speciation diagrams building by means of literature stability constants has allowed to define the analytical conditions of complex formation. The chosen analytical technique is the hyphenation of a separative technique (liquid chromatography LC or capillary electrophoresis CE) with mass spectrometry (ICPMS). The studied complexes presence in the synthetic samples has been confirmed with UV/visible spectrophotometry. LC-ICPMS analyses have proved the lability of the uranyl-organic acid complexes, namely their tendency to dissociate during analysis, which prevents from studying uranium speciation. CE-ICPMS study of labile complexes from a metal-ligand system has been made possible by employing affinity capillary electrophoresis, which enables to determine stability constants and electrophoretic mobilities. This PhD thesis has allowed to compare the different mathematical treatments of binding isotherm and to take into account ionic strength and real ligand concentration. Affinity CE has been applied successfully to lanthanum-oxalate (model system) and uranium-oxalate systems. The obtained results have been applied to a real system (situated in Le Bouchet). This shows the contribution of the developed method to the modelling of uranium speciation. (author)

  15. Uncovering category specificity of genital sexual arousal in women: The critical role of analytic technique.

    Science.gov (United States)

    Pulverman, Carey S; Hixon, J Gregory; Meston, Cindy M

    2015-10-01

    Based on analytic techniques that collapse data into a single average value, it has been reported that women lack category specificity and show genital sexual arousal to a large range of sexual stimuli including those that both match and do not match their self-reported sexual interests. These findings may be a methodological artifact of the way in which data are analyzed. This study examined whether using an analytic technique that models data over time would yield different results. Across two studies, heterosexual (N = 19) and lesbian (N = 14) women viewed erotic films featuring heterosexual, lesbian, and gay male couples, respectively, as their physiological sexual arousal was assessed with vaginal photoplethysmography. Data analysis with traditional methods comparing average genital arousal between films failed to detect specificity of genital arousal for either group. When data were analyzed with smoothing regression splines and a within-subjects approach, both heterosexual and lesbian women demonstrated different patterns of genital sexual arousal to the different types of erotic films, suggesting that sophisticated statistical techniques may be necessary to more fully understand women's genital sexual arousal response. Heterosexual women showed category-specific genital sexual arousal. Lesbian women showed higher arousal to the heterosexual film than the other films. However, within subjects, lesbian women showed significantly different arousal responses suggesting that lesbian women's genital arousal discriminates between different categories of stimuli at the individual level. Implications for the future use of vaginal photoplethysmography as a diagnostic tool of sexual preferences in clinical and forensic settings are discussed. © 2015 Society for Psychophysiological Research.

  16. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  17. [Study on standardization of cupping technique: elucidation on the establishment of the National Standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping].

    Science.gov (United States)

    Gao, Shu-zhong; Liu, Bing

    2010-02-01

    From the aspects of basis, technique descriptions, core contents, problems and solutions, and standard thinking in standard setting process, this paper states experiences in the establishment of the national standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping, focusing on methodologies used in cupping standard setting process, the method selection and operating instructions of cupping standardization, and the characteristics of standard TCM. In addition, this paper states the scope of application, and precautions for this cupping standardization. This paper also explaines tentative ideas on the research of standardized manipulation of acupuncture and moxibustion.

  18. Channelling enhanced microanalysis: A high resolution analytical technique for atomic site and species determination

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, K.N.

    1987-11-01

    The formulation, development and applications of novel crystallographic technique to determine sepcific-site occupations of elemental additions in crystalline materials, using the channeling or Borrman effect in electron diffraction, is reviewed. This technique is based on the effect of incident beam orientations on the intensities of either the characteristic x-ray emissions or the characteristic electron energy-loss edges. The formulation of the technique under both planer and axial channeling conditions for crystalline materials is presented. In general, this technique can distinguish neighbors in the periodic table; involves no adjustable parameters, external standards or special specimen preparations; is applicable to trace elemental concentrations (0.2-0.3 wt % or 10/sup 25/ atoms/m/sup 3/); is very accurate and can be applied routinely at high spatial resolutions (approx.10-40nm). In the EELS formulation the technique can also provide specific site valence information. Finally, applications of this technique to site-occupation studies in a variety of materials is outlined. 35 refs., 6 figs., 1 tab.

  19. Beta Autoradiography. An analytical technique to investigate radionuclides contamination on surface

    International Nuclear Information System (INIS)

    Ficher, P.; Goutelard, F.; Siitari-Kauppi, M.

    2012-01-01

    In decommissioning of old buildings and after disposal of nuclear facilities (materials, glove boxes,...), the inventory of the radioactive contamination of various building materials needs to be obtained in order to fix the working condition for dismantling. The challenge of this study was to classify different building materials of a whole research laboratory that was dedicated to research on organic molecules labeled with H-3 and C-14. The problem of waste classification is essential for safety treatment of waste and also for its cost. The analytical technique of beta autoradiography particularly well known for biological researches has been tested to investigate radionuclides contamination on surface. This technique is mainly interesting for beta and alpha emitters but also sensitive to gamma radiation. The first step of this technique is the deposit of a film on the surface of material to be analyzed. Films can be deposited on the ground or also fixed on the walls or even on the ceiling. The film is a plastic sheet covered with an emulsion containing photostimulable crystals and Eu that is activated when the film is exposed on radioactive source. The exposed films are then scanned with the Cyclone Plus equipment to get a digitized image. This image represents the radioactivity of the surface studied. The possibility to re-use the films is very important to investigate a large area. This autoradiography technique has retained our attention for its sensitivity and moreover the possibility of 2-dimensional investigation has been found as a real advantage. However it remains now as a qualitative technique and new studies must be launched to prove its quantitative potentialities. The high spatial resolution was not as important as in biological observation, and the mm resolution is totally sufficient

  20. Review of the various analytical techniques and algorithms for detection and quantification of TATP

    Science.gov (United States)

    Pacheco-Londono, Leonardo; Primera, Oliva M.; Ramirez, Michael; Ruiz, Orlando; Hernandez-Rivera, Samuel

    2005-05-01

    The objective of this research is to design and develop a multi-sensor capable of fast detection and of recognition optimization of the techniques for used for quantification of TATP by Pattern Recognition. In particular, the long range goal of the research is to use sensor fusion and sensor "talking" modalities to couple Stand Off detectors with Chemical Point detectors for detection of airborne chemical agents and detection of Improvised Explosive Devices (IEDs). Vibrational spectroscopy techniques are very fast and can be used for real time detection. Good results have been obtained with various target molecular (chemical) systems such as TATP, TNT and DNT. Samples of TATP were detected and quantified in air, in solution and in solid phase on surfaces by different techniques. FTIR Spectroscopy and GS-MS were used to generate new analytical procedures for detection and analysis of the organic peroxide. These procedures were compared and taken to their limits by optimization with Chemometrics, Partial Least Squares (PLS), and Discriminant Analysis (DA).

  1. Multielement determination in Cuban red mangrove samples using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Estevez Alvarez, J.R.; Aguiar Lambert, D.; Montero Alvarez, A.; Pupo Gonzalez, I.; Padilla Alvarez, R.; Gonzalez Garcia, H.; Ramirez Sasco, M.

    1998-01-01

    In the present work the contents of Al; K; Ca; Mn; Fe; Ni; Cu; Zn; Sr; Cd and Pb in red mangroves (Rhizophora mangle) from different Cuban regions are determined, using Energy Dispersive X-Ray Fluorescence (Emission-Transmission (Et) and I/C methods), Atomic Absorption Spectrophotometry (AAS), and Polarography (Anodic Stripping Voltametry method). Biological Certified Reference Materials (CRM) are employed for the tracing of the tracing of the curves of the relative I/C method and for the evaluation of the analytical results accuracy. The reliability of the results is also checked by statistical means. Standard deviations and the detection limits of each method are reported. Finally, the obtained values for the concentration of the different elements in each studied ecosystem are presented; a detailed discussion about their significance will be performed in a further paper

  2. Capillary electromigration techniques for studying interactions between analytes and lipid dispersions.

    Science.gov (United States)

    Wiedmer, Susanne K; Lokajová, Jana

    2013-01-01

    CE has matured into a well-known and much used separation technique, with applications covering more or less all types of samples. EKC, which originally was developed for the separation of uncharged compounds, is still today under much development, with main focus on finding the perfect or ideal carriers (pseudo-stationary phase) for a broad range of analytes. In this review, the use of lipid dispersions as pseudostationary phases in EKC performed in capillaries and microchips, in addition to CE frontal analysis and partial filling EKC using lipid dispersions is discussed. Various types of lipid dispersions including liposomes, PEG-stabilized aggregates, proteoliposomes, lipid-based nanoparticles, and commercial lipid emulsions are described. The purpose of the review is to give the reader an overview of how EKC, CE frontal analysis, and partial filling EKC, have been applied to the study of interactions between analytes and lipid membranes. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Study of the analytic quality in the determinations of Cr, Fe, Mn, Cu, Zn, Pb and Hg through conventional and nuclear analytical techniques in mosses of the MATV

    International Nuclear Information System (INIS)

    Caballero S, B.

    2013-01-01

    To evaluate the environmental risks of air pollution and to facilitate the decision-making for control, is necessary to have the capacity to generate data with analytical quality. A comparison between nuclear (Neutron activation analysis and total reflection X-ray fluorescence spectrometry) and no nuclear analytical techniques (atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry) for simultaneous determination of metal content (Cr, Cu, Fe, Hg, Mn, Pb and Zn) in mosses from Metropolitan Area of the Toluca Valley (MATV) was performed. Epiphytic mosses (Fabriona ciliaris and Leskea angustata) were sampled in two campaigns, 16 sites (urban, transition and natural) and were prepared for each technique. The biological certified reference materials were used for the quality control and to evaluate accuracy, precision, linearity, detection and quantification limits. Results show that nuclear analytical techniques and no nuclear applied in chemical analysis of Cr, Cu, Fe, Hg, Mn, Pb and Zn in moss from MATV are comparable and therefore all of these can potentially be used for this purpose. However, if its considered both, the performance parameters and economic/operational characteristics is widely recommended inductively coupled plasma optical emission spectrometry, conventional analytical technique, which showed the highest analytical grade quality. Also were observed spatial and temporal variations in the concentrations of Cr, Cu, Fe, Hg, Mn, Pb and Zn in mosses from MATV and was discussed its potential origin. The urban sites had the highest concentration of anthropogenic elements as Cr, Cu, Fe, Hg, Pb and Zn because are strongly impacted by roads with high vehicle traffic. (Author)

  4. Elemental composition of coal fly ash: Malta coal power station in the Mpumalanga province in South Africa case study using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Eze, Ch.P.; Fatoba, O.; Madzivire, G.; Petrik, L.F.; Ostrovnaya, T.M.; Frontas'eva, M.V.; Nechaev, A.N.

    2013-01-01

    Epithermal neutron activation analysis along with ICP-OES, LA ICP-MS, and XRF were used to determine the elemental composition of coal fly ash from the Malta coal power station in the Mpumalanga province of South Africa. A total of 54 major, trace and rare-earth elements were obtained by the four analytical techniques. The results were compared and the discrepancies discussed to show the merits and drawbacks of each of the techniques. It was shown that the elemental content of this particular coal fly ash is of the same order as the NIST standard reference material Coal Fly Ash 1633b

  5. Production of candidate natural matrix reference materials for micro-analytical techniques

    International Nuclear Information System (INIS)

    Zeisler, R.; Fajgelj, A.; Zeiller, E.

    2002-01-01

    Homogeneity is considered to be the most vital prerequisite for a certified reference material (CRM); more stringent requirements exist for the analysis of small subsamples. Many of the natural matrix CRMs are prepared from bulk samples by grinding and milling them to a certain particle size, which is expected to provide a more homogenous material; however recommended sample sizes for biological and environmental reference materials are found to be more than 100 mg. Since the milling of materials is costly and has some drawbacks, natural materials that already occur as small particles such as air particulate matter, certain sediments, and cellular biological materials may form the basis of the required reference materials. The nature of these materials, i.e. naturally occurring particles, may provide ideal model reference material. We describe here the production of the materials and preliminary tests, the evaluation for the micro-analytical techniques

  6. Identification of purple dye from molluscs on an excavated textile by non-destructive analytical techniques

    DEFF Research Database (Denmark)

    Margariti, Christina; Protopapas, Stavros; Allen, Norman

    2013-01-01

    , the application of non-destructive methods of investigation for the extraction of the data present is imperative. This paper presents the results of dye analysis performed on the excavated textile find HTR-73 from the Kerameikos cemetery in Athens. The Kerameikos textile find is from the 5th century BC, and has...... been preserved in association with copper. The techniques applied were Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray (EDX) analysis, Cathodoluminescence and micro Raman. For the first time Cathodoluminescence from an indigoid compound is reported. Comparison of the analysis results...... on samples from the find with the contemporary reference samples lead to the identification of purple dye as a dibromoindigo compound with the origin from molluscs of Murex trunculus species. The application of non-destructive analytical methods of investigation was successful in analysing dyes on excavated...

  7. Use of the analytical tree technique to develop a radiological protection program

    International Nuclear Information System (INIS)

    Domenech N, H.; Jova S, L.

    1996-01-01

    The results obtained by the Cuban Center for Radiological Protection and Hygiene by using an analytical tree technique to develop its general operational radiation protection program are presented. By the application of this method, some factors such as the organization of the radiation protection services, the provision of administrative requirements, the existing general laboratories requirements, the viability of resources and the current documentation was evaluated. Main components were considered such as: complete normative and regulatory documentation; automatic radiological protection data management; scope of 'on the-job'and radiological protection training for the personnel; previous radiological appraisal for the safety performance of the works and application of dose constrains for the personnel and the public. The detailed development of the program allowed to identify the basic aims to be achieved in its maintenance and improvement. (authors). 3 refs

  8. Investigation of different types of filters for atmospheric trace elements analysis by three analytical techniques

    International Nuclear Information System (INIS)

    Ali, A.E.; Bacso, J.

    1996-01-01

    Different atmospheric aerosol samples were collected on three types of filters. Disks of both loaded and clean areas of each kind of filter were investigated by XRF, PIXE and Scanning Electron Microscope (SEM) methods. The blank concentration values of the elements Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br and Pb in the three types of filters are discussed. It is found that for trace elemental analysis, the Nuclepore membrane filters are the most suitable for sampling. These have much lower blank element concentration values than the glass fibres and ash free filters. It was found also that the PIXE method is a more reliable analytical technique for atmospheric aerosol particles than the other methods. (author). 20 refs., 3 figs., 3 tabs

  9. Preparation of uranium targets and application of analytical techniques for its evaluation

    International Nuclear Information System (INIS)

    Luna Z, D.

    1994-01-01

    The objective of this work is to establish a method to produce uranium targets. The method selected for this purpose was the molecular plating. The first part of this work is devoted to the proper selection of an analytical technique to evaluate the different steps of the molecular plating method. Neutron Activation Analysis was chosen, because its high sensitivity and can be adapted easily to follow the whole procedure. The second part presents the experimental procedure and the study of the different parameters involved in the molecular plating and the evaluation of its uniformity was made using plastic track detectors. The results obtained are presented and a procedure is suggested to produce uranium targets. (Author)

  10. Role of nuclear analytical probe techniques in biological trace element research

    International Nuclear Information System (INIS)

    Jones, K.W.; Pounds, J.G.

    1985-01-01

    Many biomedical experiments require the qualitative and quantitative localization of trace elements with high sensitivity and good spatial resolution. The feasibility of measuring the chemical form of the elements, the time course of trace elements metabolism, and of conducting experiments in living biological systems are also important requirements for biological trace element research. Nuclear analytical techniques that employ ion or photon beams have grown in importance in the past decade and have led to several new experimental approaches. Some of the important features of these methods are reviewed here along with their role in trace element research, and examples of their use are given to illustrate potential for new research directions. It is emphasized that the effective application of these methods necessitates a closely integrated multidisciplinary scientific team. 21 refs., 4 figs., 1 tab

  11. On the analytical continuation of the partial wave S-matrix using complex scaling techniques

    International Nuclear Information System (INIS)

    Rittby, M.; Elander, N.; Braendas, E.

    1989-01-01

    The analytic properties of the partial wave S-matrix and related quantities are studied and numerically investigated. The analysis is carried out by means of integration along paths in the complex k-plane. The domain for the choice of integration contours can be rigorously defined by the use of complex scaling techniques. A generalization of Levinson's theorem incorporating the poles in the lower half k-plane is proved and exemplified. An expansion theorem for the partial wave S-matrix in terms of its poles and residues is derived and analyzed. The connections between poles and associated residues and their relationships with the Breit-Wigner ansatz and the Fano line shape parameters are discussed and numerically realized. Finally, the implications of the present development in connection with the inversion problem are indicated. (orig.)

  12. Endotoxin exposure in sewage treatment workers: investigation of exposure variability and comparison of analytical techniques.

    Science.gov (United States)

    Spaan, Suzanne; Smit, Lidwien A M; Eduard, Wijnand; Larsson, Lennart; Arts, Huib J J M; Wouters, Inge M; Heederik, Dick J J

    2008-01-01

    Objectives were to give an overview of endotoxin exposure and its determinants in sewage treatment workers, and to study exposure to culturable and non-culturable microorganisms and the applicability of the LAL assay in this work environment. In 43 Dutch sewage treatment plants 470 full-shift, 123 task-based personal and 54 stationary inhalable dust samples were collected. Endotoxin concentration was determined with the LAL-assay. Mixed effects models were used to investigate possible determinants of exposure. Simultaneous parallel filter samples, impinger samples and viable total bacteria and Gram-negative bacterial samples were taken to compare analytical techniques. Filter and impinger samples were analyzed with the LAL-assay, gas chromatography-mass spectrometry (GC-MS) and fluorescence microscopy. Endotoxin exposure levels were moderate to low (geometric mean personal exposure 27 EU/m(3), stationary 33 EU/m(3), task-based 64 EU/m(3)), yet differences between jobs and sources and some determinants of exposure were identified. Exposure varied more from day to day than between workers. Concentrations in filter samples were higher and more consistent than in impinger samples. Fungi and Gram-positive bacteria were found in higher levels than Gram-negative bacteria. The LAL assay and GC-MS showed comparable endotoxin levels. Endotoxin exposure in Dutch sewage treatment workers was relatively low. Comparison of sampling and analytical techniques suggests that the LAL-assay did not result in much exposure misclassification. It thus seems justified to perform filter measurements in combination with the LAL-assay to measure endotoxin exposure in sewage treatment plants.

  13. Pedestrian-vehicle crashes and analytical techniques for stratified contingency tables.

    Science.gov (United States)

    Al-Ghamdi, Ali S

    2002-03-01

    In 1999 there were 450 fatalities due to road crashes in Riyadh, the capital of Saudi Arabia, of which 130 were pedestrians. Hence, every fourth person killed on the roads is a pedestrian. The aim of this study is to investigate pedestrian-vehicle crashes in this fast-growing city with two objectives in mind: to analyze pedestrian collisions with regard to their causes, characteristics, location of injury on the victim's body, and most common patterns and to determine the potential for use of the odds ratio technique in the analysis of stratified contingency tables. Data from 638 pedestrian-vehicle crashes reported by police, during the period 1997-1999, were used. A systematic sampling technique was followed in which every third record was used. The analysis showed that the pedestrian fatality rate per 10(5) population is 2.8. The rates were relatively high within the childhood (1-9 years) and young adult (10-19 years) groups, and the old-age groups (60 - > 80 years), which indicate that young as well as the elderly people in this city are more likely to be involved in fatal accidents of this type than are those in other age groups. The analysis revealed that 77.1% of pedestrians were probably struck while crossing a roadway either not in a crosswalk or where no crosswalk existed. In addition, the distribution of injuries on the victims' bodies was determined from hospital records. More than one-third of the fatal injuries were located on the head and chest. An attempt was made to conduct an association analysis between crash severity (i.e. injury or fatal) and some of the study variables using chi-square and odds ratio techniques. The categorical nature of the data helped in using these analytical techniques.

  14. An integrated approach using orthogonal analytical techniques to characterize heparan sulfate structure.

    Science.gov (United States)

    Beccati, Daniela; Lech, Miroslaw; Ozug, Jennifer; Gunay, Nur Sibel; Wang, Jing; Sun, Elaine Y; Pradines, Joël R; Farutin, Victor; Shriver, Zachary; Kaundinya, Ganesh V; Capila, Ishan

    2017-02-01

    Heparan sulfate (HS), a glycosaminoglycan present on the surface of cells, has been postulated to have important roles in driving both normal and pathological physiologies. The chemical structure and sulfation pattern (domain structure) of HS is believed to determine its biological function, to vary across tissue types, and to be modified in the context of disease. Characterization of HS requires isolation and purification of cell surface HS as a complex mixture. This process may introduce additional chemical modification of the native residues. In this study, we describe an approach towards thorough characterization of bovine kidney heparan sulfate (BKHS) that utilizes a variety of orthogonal analytical techniques (e.g. NMR, IP-RPHPLC, LC-MS). These techniques are applied to characterize this mixture at various levels including composition, fragment level, and overall chain properties. The combination of these techniques in many instances provides orthogonal views into the fine structure of HS, and in other instances provides overlapping / confirmatory information from different perspectives. Specifically, this approach enables quantitative determination of natural and modified saccharide residues in the HS chains, and identifies unusual structures. Analysis of partially digested HS chains allows for a better understanding of the domain structures within this mixture, and yields specific insights into the non-reducing end and reducing end structures of the chains. This approach outlines a useful framework that can be applied to elucidate HS structure and thereby provides means to advance understanding of its biological role and potential involvement in disease progression. In addition, the techniques described here can be applied to characterization of heparin from different sources.

  15. Analytical chemistry

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The division for Analytical Chemistry continued to try and develope an accurate method for the separation of trace amounts from mixtures which, contain various other elements. Ion exchange chromatography is of special importance in this regard. New separation techniques were tried on certain trace amounts in South African standard rock materials and special ceramics. Methods were also tested for the separation of carrier-free radioisotopes from irradiated cyclotron discs

  16. Multicriteria evaluation of power plants impact on the living standard using the analytic hierarchy process

    International Nuclear Information System (INIS)

    Chatzimouratidis, Athanasios I.; Pilavachi, Petros A.

    2008-01-01

    The purpose of this study is to evaluate 10 types of power plants available at present including fossil fuel, nuclear as well as renewable-energy-based power plants, with regard to their overall impact on the living standard of local communities. Both positive and negative impacts of power plant operation are considered using the analytic hierarchy process (AHP). The current study covers the set of criteria weights considered typical for many local communities in many developed countries. The results presented here are illustrative only and user-defined weighting is required to make this study valuable for a specific group of users. A sensitivity analysis examines the most important weight variations, thus giving an overall view of the problem evaluation to every decision maker. Regardless of criteria weight variations, the five types of renewable energy power plant rank in the first five positions. Nuclear plants are in the sixth position when priority is given to quality of life and last when socioeconomic aspects are valued more important. Natural gas, oil and coal/lignite power plants rank between sixth and tenth position having slightly better ranking under priority to socioeconomic aspects

  17. Integration of datasets from different analytical techniques to assess the impact of nutrition on human metabolome

    Directory of Open Access Journals (Sweden)

    Pamela eVernocchi

    2012-12-01

    Full Text Available Bacteria colonizing the human intestinal tract exhibit a high phylogenetic diversity that reflects their immense metabolic potentials. The catalytic activity of gut microbes has an important impact on gastrointestinal (GI functions and host health. The microbial conversion of carbohydrates and other food components leads to the formation of a large number of compounds that affect the host metabolome and have beneficial or adverse effects on human health. Meabolomics is a metabolic-biology system approach focused on the metabolic responses understanding of living systems to physio-pathological stimuli by using multivariate statistical data on human body fluids obtained by different instrumental techniques. A metabolomic approach based on an analytical platform could be able to separate, detect, characterize and quantify a wide range of metabolites and its metabolic pathways. This approach has been recently applied to study the metabolic changes triggered in the gut microbiota by specific diet components and diet variations, specific diseases, probiotic and synbiotic food intake.This review describes the metabolomic data obtained by analyzing human fluids by using different techniques and particularly Gas Chromatography Mass Spectrometry Solid-phase Micro Extraction (GC-MS/SPME, Proton Nuclear Magnetic Resonance (1H-NMR Spectroscopy and Fourier Transform Infrared (FTIR Spectroscopy. This instrumental approach have a good potential in the identification and detection of specific food intake and diseases biomarkers.

  18. Understanding changes over time in workers' compensation claim rates using time series analytical techniques.

    Science.gov (United States)

    Moore, Ian C; Tompa, Emile

    2011-11-01

    The objective of this study is to better understand the inter-temporal variation in workers' compensation claim rates using time series analytical techniques not commonly used in the occupational health and safety literature. We focus specifically on the role of unemployment rates in explaining claim rate variations. The major components of workers' compensation claim rates are decomposed using data from a Canadian workers' compensation authority for the period 1991-2007. Several techniques are used to undertake the decomposition and assess key factors driving rates: (i) the multitaper spectral estimator, (ii) the harmonic F test, (iii) the Kalman smoother and (iv) ordinary least squares. The largest component of the periodic behaviour in workers' compensation claim rates is seasonal variation. Business cycle fluctuations in workers' compensation claim rates move inversely to unemployment rates. The analysis suggests that workers' compensation claim rates between 1991 and 2008 were driven by (in order of magnitude) a strong negative long term growth trend, periodic seasonal trends and business cycle fluctuations proxied by the Ontario unemployment rate.

  19. The study of trace elements in milk by nuclear analytical techniques

    International Nuclear Information System (INIS)

    Gharib, A.; Rahimi, H.; Peyrovan, H.; Raofei, H.N.J.; Taherpour, H.

    1983-01-01

    This work is part of a project with the IAEA, in a coordinated programme on ''Trace Elements in Human Nutrition and Bio-Environmental Systems'' to evaluate their nutritional requirements, interrelations and the role of Trace Elements in health, metabolism etc. Cow's milk being regarded as one of the most important and nutritious foodstuffs consumed by people. Hence as a first step, an elemental analysis for milk was carried out for this purpose so a few samples of pasteurized milk and local samples were investigated for essential and toxic trace elements. The secondary aim of this project was the assessment of various analytical techniques involved. However, in the present work, the methods involved were AAS, PIXE and NAA. The latter method applied, both instrumentally and radiochemically. Although the results pertaining to the various methods employed are not in good agreement, there is however, some justification to clarify this internal inconsistency. The precision for NAA and AAS allows greater degree of acceptance respectively. Although PIXE is a very fast and rather a routine but the technique of trace element analysis needs certain adaptations and developments

  20. Analytical transform techniques to retrieve non-spherical particle size distribution

    International Nuclear Information System (INIS)

    Zhao, Jian-Qi; Li, Jiangnan

    2013-01-01

    The measurement of particle size distribution (PSD) from the extinction spectra is a challenging problem, especially for non-spherical particles. In this work, the analytical transform techniques are developed to retrieve PSD from the measured scattering data for a variety of shapes of non-spherical particle including spheroids, cuboids, triangular prisms, hexagonal prisms and elliptical cylinders. In the retrieve calculation, all particles have aligned orientations and their extinction cross sections can be adequately calculated by using the anomalous diffraction theory (ADT). It is shown that for each type of the considered non-spherical particles, there exists an ADT transform pair between the size distribution and the extinction spectrum. The inverse formula of PSD from the related ADT transform is therefore established. This result provides a new approach to the solution of the inversion problem and has the potential to be used in finding solutions for more complicated particle shapes. It is found that the solution of inverse scattering for absorbing particles can be simplified to a particular solution in which the character of absorption becomes no longer present. For spheroids, triangular prisms, and elliptical cylinders, the retrieved PSD and the corresponding true PSD always belong to one family of function, due to the scaling relation. Therefore an improper choice of inversion parameters does not significantly affect the type of mode of PSD in a retrieval process. -- Highlights: •Analytical schemes for inversion of non-spherical particle size distribution. •Intuitive inverse formulas and novel ADT transform fairs for non-spherical particles. •Useful scaling relations in retrievals for non-spherical particles

  1. Employing socially driven techniques for framing, contextualization, and collaboration in complex analytical threads

    Science.gov (United States)

    Wollocko, Arthur; Danczyk, Jennifer; Farry, Michael; Jenkins, Michael; Voshell, Martin

    2015-05-01

    The proliferation of sensor technologies continues to impact Intelligence Analysis (IA) work domains. Historical procurement focus on sensor platform development and acquisition has resulted in increasingly advanced collection systems; however, such systems often demonstrate classic data overload conditions by placing increased burdens on already overtaxed human operators and analysts. Support technologies and improved interfaces have begun to emerge to ease that burden, but these often focus on single modalities or sensor platforms rather than underlying operator and analyst support needs, resulting in systems that do not adequately leverage their natural human attentional competencies, unique skills, and training. One particular reason why emerging support tools often fail is due to the gap between military applications and their functions, and the functions and capabilities afforded by cutting edge technology employed daily by modern knowledge workers who are increasingly "digitally native." With the entry of Generation Y into these workplaces, "net generation" analysts, who are familiar with socially driven platforms that excel at giving users insight into large data sets while keeping cognitive burdens at a minimum, are creating opportunities for enhanced workflows. By using these ubiquitous platforms, net generation analysts have trained skills in discovering new information socially, tracking trends among affinity groups, and disseminating information. However, these functions are currently under-supported by existing tools. In this paper, we describe how socially driven techniques can be contextualized to frame complex analytical threads throughout the IA process. This paper focuses specifically on collaborative support technology development efforts for a team of operators and analysts. Our work focuses on under-supported functions in current working environments, and identifies opportunities to improve a team's ability to discover new information and

  2. Development of an absolute x-ray fluorescence technique and high accuracy analytical methods for the determination of metals in catalytic materials

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Parker, W.C.

    1982-09-01

    A technique to produce characteristic x-rays by direct beta excitation for x-ray fluorescence analysis is presented. This is carried out by the introduction of 100 uCi of Pm-147 or Ni-63 to a small sample, which is placed directly in the window of a modified Si(Li) semiconductor. Corrected intensities are only given at 300 seconds for synthetic standards oscillating within the range 22 3 was used, to which the radioisotope was directly added. Preliminary results of the determination of eleven different radionuclides by means of an elementary x-ray analysis by using a new analytical technique, are discussed. In this technique the radioisotope and the sample are directly mixed, then this source-sample in the detector window and is protected from contamination with a thin plastic film. Future and possible applications of this technique are presented

  3. Standard errors and confidence intervals for correlations corrected for indirect range restriction: A simulation study comparing analytic and bootstrap methods.

    Science.gov (United States)

    Kennet-Cohen, Tamar; Kleper, Dvir; Turvall, Elliot

    2018-02-01

    A frequent topic of psychological research is the estimation of the correlation between two variables from a sample that underwent a selection process based on a third variable. Due to indirect range restriction, the sample correlation is a biased estimator of the population correlation, and a correction formula is used. In the past, bootstrap standard error and confidence intervals for the corrected correlations were examined with normal data. The present study proposes a large-sample estimate (an analytic method) for the standard error, and a corresponding confidence interval for the corrected correlation. Monte Carlo simulation studies involving both normal and non-normal data were conducted to examine the empirical performance of the bootstrap and analytic methods. Results indicated that with both normal and non-normal data, the bootstrap standard error and confidence interval were generally accurate across simulation conditions (restricted sample size, selection ratio, and population correlations) and outperformed estimates of the analytic method. However, with certain combinations of distribution type and model conditions, the analytic method has an advantage, offering reasonable estimates of the standard error and confidence interval without resorting to the bootstrap procedure's computer-intensive approach. We provide SAS code for the simulation studies. © 2017 The British Psychological Society.

  4. Technique for fabrication of gradual standards of radiographic image blachening density

    International Nuclear Information System (INIS)

    Borovin, I.V.; Kondina, M.A.

    1987-01-01

    The technique of fabrication of gradual standards of blackening density for industrial radiography by contact printing from a negative is described. The technique is designed for possibilities of industrial laboratoriesof radiation defectoscopy possessing no special-purpose sensitometric equipment

  5. Metabolomic analysis using porcine skin: a pilot study of analytical techniques.

    Science.gov (United States)

    Wu, Julie; Fiehn, Oliver; Armstrong, April W

    2014-06-15

    Metabolic byproducts serve as indicators of the chemical processes and can provide valuable information on pathogenesis by measuring the amplified output. Standardized techniques for metabolome extraction of skin samples serve as a critical foundation to this field but have not been developed. We sought to determine the optimal cell lysage techniques for skin sample preparation and to compare GC-TOF-MS and UHPLC-QTOF-MS for metabolomic analysis. Using porcine skin samples, we pulverized the skin via various combinations of mechanical techniques for cell lysage. After extraction, the samples were subjected to GC-TOF-MS and/or UHPLC-QTOF-MS. Signal intensities from GC-TOF-MS analysis showed that ultrasonication (2.7x107) was most effective for cell lysage when compared to mortar-and-pestle (2.6x107), ball mill followed by ultrasonication (1.6x107), mortar-and-pestle followed by ultrasonication (1.4x107), and homogenization (trial 1: 8.4x106; trial 2: 1.6x107). Due to the similar signal intensities, ultrasonication and mortar-and-pestle were applied to additional samples and subjected to GC-TOF-MS and UHPLC-QTOF-MS. Ultrasonication yielded greater signal intensities than mortar-and-pestle for 92% of detected metabolites following GC-TOF-MS and for 68% of detected metabolites following UHPLC-QTOF-MS. Overall, ultrasonication is the preferred method for efficient cell lysage of skin tissue for both metabolomic platforms. With standardized sample preparation, metabolomic analysis of skin can serve as a powerful tool in elucidating underlying biological processes in dermatological conditions.

  6. Elementary mechanics using Python a modern course combining analytical and numerical techniques

    CERN Document Server

    Malthe-Sørenssen, Anders

    2015-01-01

    This book – specifically developed as a novel textbook on elementary classical mechanics – shows how analytical and numerical methods can be seamlessly integrated to solve physics problems. This approach allows students to solve more advanced and applied problems at an earlier stage and equips them to deal with real-world examples well beyond the typical special cases treated in standard textbooks. Another advantage of this approach is that students are brought closer to the way physics is actually discovered and applied, as they are introduced right from the start to a more exploratory way of understanding phenomena and of developing their physical concepts. While not a requirement, it is advantageous for the reader to have some prior knowledge of scientific programming with a scripting-type language. This edition of the book uses Python, and a chapter devoted to the basics of scientific programming with Python is included. A parallel edition using Matlab instead of Python is also available. Last but not...

  7. Elementary mechanics using Matlab a modern course combining analytical and numerical techniques

    CERN Document Server

    Malthe-Sørenssen, Anders

    2015-01-01

    This book – specifically developed as a novel textbook on elementary classical mechanics – shows how analytical and numerical methods can be seamlessly integrated to solve physics problems. This approach allows students to solve more advanced and applied problems at an earlier stage and equips them to deal with real-world examples well beyond the typical special cases treated in standard textbooks. Another advantage of this approach is that students are brought closer to the way physics is actually discovered and applied, as they are introduced right from the start to a more exploratory way of understanding phenomena and of developing their physical concepts. While not a requirement, it is advantageous for the reader to have some prior knowledge of scientific programming with a scripting-type language. This edition of the book uses Matlab, and a chapter devoted to the basics of scientific programming with Matlab is included. A parallel edition using Python instead of Matlab is also available. Last but not...

  8. Nuclear analytical techniques applied to the large scale measurements of atmospheric aerosols in the amazon region

    International Nuclear Information System (INIS)

    Gerab, Fabio

    1996-03-01

    This work presents the characterization of the atmosphere aerosol collected in different places of the Amazon Basin. We studied both the biogenic emission from the forest and the particulate material which is emitted to the atmosphere due to the large scale man-made burning during the dry season. The samples were collected during a three year period at two different locations in the Amazon, namely the Alta Floresta (MT) and Serra do Navio (AP) regions, using stacked unit filters. These regions represent two different atmospheric compositions: the aerosol is dominated by the forest natural biogenic emission at Serra do Navio, while at Alta Floresta it presents an important contribution from the man-made burning during the dry season. At Alta Floresta we took samples in gold in order to characterize mercury emission to the atmosphere related to the gold prospection activity in Amazon. Airplanes were used for aerosol sampling during the 1992 and 1993 dry seasons to characterize the atmospheric aerosol contents from man-made burning in large Amazonian areas. The samples were analyzed using several nuclear analytic techniques: Particle Induced X-ray Emission for the quantitative analysis of trace elements with atomic number above 11; Particle Induced Gamma-ray Emission for the quantitative analysis of Na; and Proton Microprobe was used for the characterization of individual particles of the aerosol. Reflectancy technique was used in the black carbon quantification, gravimetric analysis to determine the total atmospheric aerosol concentration and Cold Vapor Atomic Absorption Spectroscopy for quantitative analysis of mercury in the particulate from the Alta Floresta gold shops. Ionic chromatography was used to quantify ionic contents of aerosols from the fine mode particulate samples from Serra do Navio. Multivariate statistical analysis was used in order to identify and characterize the sources of the atmospheric aerosol present in the sampled regions. (author)

  9. Multi-criteria approach with linear combination technique and analytical hierarchy process in land evaluation studies

    Directory of Open Access Journals (Sweden)

    Orhan Dengiz

    2018-01-01

    Full Text Available Land evaluation analysis is a prerequisite to achieving optimum utilization of the available land resources. Lack of knowledge on best combination of factors that suit production of yields has contributed to the low production. The aim of this study was to determine the most suitable areas for agricultural uses. For that reasons, in order to determine land suitability classes of the study area, multi-criteria approach was used with linear combination technique and analytical hierarchy process by taking into consideration of some land and soil physico-chemical characteristic such as slope, texture, depth, derange, stoniness, erosion, pH, EC, CaCO3 and organic matter. These data and land mapping unites were taken from digital detailed soil map scaled as 1:5.000. In addition, in order to was produce land suitability map GIS was program used for the study area. This study was carried out at Mahmudiye, Karaamca, Yazılı, Çiçeközü, Orhaniye and Akbıyık villages in Yenişehir district of Bursa province. Total study area is 7059 ha. 6890 ha of total study area has been used as irrigated agriculture, dry farming agriculture, pasture while, 169 ha has been used for non-agricultural activities such as settlement, road water body etc. Average annual temperature and precipitation of the study area are 16.1oC and 1039.5 mm, respectively. Finally after determination of land suitability distribution classes for the study area, it was found that 15.0% of the study area has highly (S1 and moderately (S2 while, 85% of the study area has marginally suitable and unsuitable coded as S3 and N. It was also determined some relation as compared results of linear combination technique with other hierarchy approaches such as Land Use Capability Classification and Suitability Class for Agricultural Use methods.

  10. Atmospheric pollution in the Tula Industrial Corridor studied using a bio monitor and nuclear analytical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Martinez C, M. A.; Solis, C.; Andrade, E. [UNAM, Instituto de Fisica, Apdo. Postal 20-364, 01000 Mexico D. F. (Mexico); Beltran H, R. I. [Universidad Autonoma del Estado de Hidalgo, Centro de Investigaciones Quimicas, Carretera Pachuca-Tulancingo Km. 4.5, 42184 Pachuca, Hidalgo (Mexico); Issac O, K. [Universidad Autonoma del Estado de Mexico, Facultad de Medicina, Paseo Tollocan s/n, esq. Jesus Carranza, 50120 Toluca, Estado de Mexico (Mexico); Lucho C, C. A. [Universidad Politecnica de Pachuca, Carretera Pachuca-Cd. Sahagun Km. 20, Hidalgo (Mexico); Lopez R, M. C.; Longoria, L. C. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-02-15

    This study deals with the application of nuclear analytical techniques to analyze trace elements in the biological monitor Tillandsia usneoides. Biological monitors provides an alternative advantageous way of particulate matter sampling in air pollution studies, since there is no need of special sampling devices, accumulation time can be as long as desired. T. usneoides, which occurs naturally throughout Mexico, was used to monitor air quality of Tula-Vito-Apasco (TVA) industrial corridor at central Mexico. This area is considered one of the critical zones of the country because of atmospheric contaminants high concentration. Particulate matter is regulated by Mexican norms, but its chemical composition is not. Plants were transplanted from a clean environment to four sites at the TVA corridor, and exposed for 12 weeks from February to April 2008. Trace element accumulation of plants was determined by particle induced X-ray emission and neutron activation analysis. Results reveal differences in trace elements distribution among sites in the TVA corridor. Furthermore, anthropogenic elements (S, V) and crustal elements (Ca) in T. usneoides exhibit high levels. Highly toxic elements such as Hg, As and Cr although present at trace levels, showed un enrichment relative to the initial values, when transplanted to the TVA corridor. Results show that monitoring with T. usneoides allows a first approximation of air sources to provide insights of the atmospheric pollution in the TVA corridor. (Author)

  11. Basic prediction techniques in modern video coding standards

    CERN Document Server

    Kim, Byung-Gyu

    2016-01-01

    This book discusses in detail the basic algorithms of video compression that are widely used in modern video codec. The authors dissect complicated specifications and present material in a way that gets readers quickly up to speed by describing video compression algorithms succinctly, without going to the mathematical details and technical specifications. For accelerated learning, hybrid codec structure, inter- and intra- prediction techniques in MPEG-4, H.264/AVC, and HEVC are discussed together. In addition, the latest research in the fast encoder design for the HEVC and H.264/AVC is also included.

  12. Characterization by FTIR and nuclear analytical techniques of CNx films elaborated by laser ablation

    International Nuclear Information System (INIS)

    Olea M, O.F.

    2003-01-01

    At the present time the technique of deposit of laser ablation is used to produce different types of thin films. At the moment in the National Institute of Nuclear Research (ININ) it is carried out an investigation on the thermoluminescent response of thin films of CN x with possible application in dosimetry of electromagnetic radiation. Under this context, the present work is part of this investigation and has as objective to characterize thin films of CN x by means of Infrared spectrometry and nuclear analytical techniques. The deposits were elaborated by laser ablation under different such experimental conditions as: pressure of Nitrogen in the system (3 x 10 -3 and 7.5 X 10 -2 Torr), Distance target-substrate (3 and 5 cm) and density of incident energy in the target (from 17.5 up to 23.8 J/cm 2 ). Graphite of high purity was used like target and the deposits were made on their substrates of intrinsic silicon (100). By means of infrared spectrometry by Fourier Transform (Ftir) the type of bonds which are in the structure of the films of CN x were determined. The spectra of this type of samples present in general four characteristic bands related with different types of bonds among the elements C, O, H, N such as: C-C, C-N, C-H, N-H, O-H, C=N, C≡N, among others. It was carried out a semi quantitative study of the samples isolating each band of the total infrared spectra and making a comparison between their intensities and forms. This study allowed to observe that there is a dependence of the structure of the films with regard to the time, since mainly bonds of the type Sp 3 between Hydrogen and Carbon (C-H) they presented a remarkable variation in intensity, increasing as it lapsed the time until reaching to a stabilization where the bonds already not varying. This increase probably is due to the absorption of water of the atmosphere, although one has seen in the literature that the incorporation of this compound in this type of samples affects mainly to the

  13. Combining Surface Analytical and Computational Techniques to Investigate Orientation Effects of Immobilized Proteins

    Science.gov (United States)

    Harrison, Elisa Turla

    Controlling how proteins are immobilized (e.g. controlling their orientation and conformation) is essential for developing and optimizing the performance of in vitro protein-binding devices, such as enzyme-linked immunosorbent assays. The objective of this work is to develop new methodologies to study proteins and complex mixtures of proteins immobilized onto surfaces. The focus of this study was to control and characterize the orientation of protein G B1, an IgG antibody-binding domain of protein G, on well-defined surfaces as well as measure the effect of protein G B1 orientation on IgG antibody binding using a variety of surface analytical and computational techniques. The surface sensitivity of time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to distinguish between different proteins and their orientation by monitoring the changes in intensity of characteristic amino acid mass fragments. Amino acids distributed asymmetrically were used to calculate peak intensity ratios from ToF-SIMS data to determine the orientation of five different cysteine mutants of protein G B1 covalently attached to a maleimide surface. To study the effect of protein orientation on antibody binding, we formed multilayer protein films by binding IgG to protein G B1 films. Quartz crystal microbalance with dissipation monitoring (QCM-D) detected protein coverages of 69-130 ng/cm2 (theoretical mass of a monolayer of protein G B1 is 110-160 ng/cm2). QCM-D and X-ray photoelectron spectroscopy analysis revealed that packing density along with orientation affected the antibody binding process. Spectra from ToF-SIMS using large Ar gas cluster ion sources distinguished between different proteins in multilayer protein systems. A Monte Carlo algorithm was developed to predict protein orientation on surfaces. Two distinct orientations of protein G B1 adsorbed onto a hydrophobic surface were found and characterized as two mutually exclusive sets of amino acids on the outermost

  14. The network formation assay: a spatially standardized neurite outgrowth analytical display for neurotoxicity screening.

    Science.gov (United States)

    Frimat, Jean-Philippe; Sisnaiske, Julia; Subbiah, Subanatarajan; Menne, Heike; Godoy, Patricio; Lampen, Peter; Leist, Marcel; Franzke, Joachim; Hengstler, Jan G; van Thriel, Christoph; West, Jonathan

    2010-03-21

    We present a rapid, reproducible and sensitive neurotoxicity testing platform that combines the benefits of neurite outgrowth analysis with cell patterning. This approach involves patterning neuronal cells within a hexagonal array to standardize the distance between neighbouring cellular nodes, and thereby standardize the length of the neurite interconnections. This feature coupled with defined assay coordinates provides a streamlined display for rapid and sensitive analysis. We have termed this the network formation assay (NFA). To demonstrate the assay we have used a novel cell patterning technique involving thin film poly(dimethylsiloxane) (PDMS) microcontact printing. Differentiated human SH-SY5Y neuroblastoma cells colonized the array with high efficiency, reliably producing pattern occupancies above 70%. The neuronal array surface supported neurite outgrowth, resulting in the formation of an interconnected neuronal network. Exposure to acrylamide, a neurotoxic reference compound, inhibited network formation. A dose-response curve from the NFA was used to determine a 20% network inhibition (NI(20)) value of 260 microM. This concentration was approximately 10-fold lower than the value produced by a routine cell viability assay, and demonstrates that the NFA can distinguish network formation inhibitory effects from gross cytotoxic effects. Inhibition of the mitogen-activated protein kinase (MAPK) ERK1/2 and phosphoinositide-3-kinase (PI-3K) signaling pathways also produced a dose-dependent reduction in network formation at non-cytotoxic concentrations. To further refine the assay a simulation was developed to manage the impact of pattern occupancy variations on network formation probability. Together these developments and demonstrations highlight the potential of the NFA to meet the demands of high-throughput applications in neurotoxicology and neurodevelopmental biology.

  15. Preliminary detection of explosive standard components with Laser Raman Technique

    International Nuclear Information System (INIS)

    Botti, S.; Ciardi, R.

    2008-01-01

    Presently, our section is leader of the ISOTREX project (Integrated System for On-line TRace EXplosives detection in solid, liquid and vapour state), funded in the frame of the PASR 2006 action (Preparatory Action on the enhancement of the European industrial potential in the field of Security Research Preparatory Action) of the 6. EC framework. ISOTREX project will exploit the capabilities of different laser techniques as LIBS (Laser Induced Breakdown Spectroscopy), LPA (Laser Photo Acustic) and CRDS (Cavity Ring Down Spectroscopy) to monitor explosive traces. In this frame, we extended our investigation also to the laser induced Raman effect spectroscopy, in order to investigate its capabilities and possible future integration. We analysed explosive samples in bulk solid phase, diluted liquid phase and as evaporated films over suitable substrate. In the following, we present the main results obtained, outlining preliminary conclusions [it

  16. An Overview of Analytical Determination of Diltiazem, Cimetidine, Ranitidine, and Famotidine by UV Spectrophotometry and HPLC Technique

    Directory of Open Access Journals (Sweden)

    Nighat Shafi

    2013-01-01

    Full Text Available This review article recapitulates the analytical methods for the quantitative determinations of diltiazem and three H2 receptor antagonists (cimetidine, ranitidine, and famotidine by one of the spectroscopic technique (UV spectrophotometery and separation technique such as high-performance liquid chromatography (HPLC. The clinical and pharmaceutical analysis of these drugs requires effective analytical procedures for quality control, pharmaceutical dosage formulations, and biological fluids. An extensive survey of the literature published in various analytical and pharmaceutical chemistry-related journals has been compiled in its review. A synopsis of reported spectrophotometric and high-performance liquid chromatographic methods for individual drug is integrated. This appraisal illustrates that majority of the HPLC methods reviewed are based on the quantitative analysis of drugs in biological fluids, and they are appropriate for therapeutic drug monitoring purpose.

  17. Computational efficiency study of a semi-analytical technique for the angular integral estimation found in transfer matrix generation

    International Nuclear Information System (INIS)

    Garcia, R.D.M.

    1984-01-01

    The computational efficiency of a semi-analytic technique recently proposed for the evaluation of certain angular integrals encountered in the generation of the isotropic and linearly anisotropic components of elastic and discrete inelastic transfer matrices is studied. It is concluded from a comparison with results obtained with the use of numerical quadratures that the technique has certain computational advantages that recommend its implementation. (Author) [pt

  18. Adsorptive micro-extraction techniques--novel analytical tools for trace levels of polar solutes in aqueous media.

    Science.gov (United States)

    Neng, N R; Silva, A R M; Nogueira, J M F

    2010-11-19

    A novel enrichment technique, adsorptive μ-extraction (AμE), is proposed for trace analysis of polar solutes in aqueous media. The preparation, stability tests and development of the analytical devices using two geometrical configurations, i.e. bar adsorptive μ-extraction (BAμE) and multi-spheres adsorptive μ-extraction (MSAμE) is fully discussed. From the several sorbent materials tested, activated carbons and polystyrene divinylbenzene phases demonstrated the best stability, robustness and to be the most suitable for analytical purposes. The application of both BAμE and MSAμE devices proved remarkable performance for the determination of trace levels of polar solutes and metabolites (e.g. pesticides, disinfection by-products, drugs of abuse and pharmaceuticals) in water matrices and biological fluids. By comparing AμE techniques with stir bar sorptive extraction based on polydimethylsiloxane phase, great effectiveness is attained overcoming the limitations of the latter enrichment approach regarding the more polar solutes. Furthermore, convenient sensitivity and selectivity is reached through AμE techniques, since the great advantage of this new analytical technology is the possibility to choose the most suitable sorbent to each particular type of application. The enrichment techniques proposed are cost-effective, easy to prepare and work-up, demonstrating robustness and to be a remarkable analytical tool for trace analysis of priority solutes in areas of recognized importance such as environment, forensic and other related life sciences. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. IBM SPSS modeler essentials effective techniques for building powerful data mining and predictive analytics solutions

    CERN Document Server

    McCormick, Keith; Wei, Bowen

    2017-01-01

    IBM SPSS Modeler allows quick, efficient predictive analytics and insight building from your data, and is a popularly used data mining tool. This book will guide you through the data mining process, and presents relevant statistical methods which are used to build predictive models and conduct other analytic tasks using IBM SPSS Modeler. From ...

  20. Ibm spss modeler essentials effective techniques for building powerful data mining and predictive analytics solutions

    CERN Document Server

    McCormick, Keith; Wei, Bowen

    2017-01-01

    IBM SPSS Modeler allows quick, efficient predictive analytics and insight building from your data, and is a popularly used data mining tool. This book will guide you through the data mining process, and presents relevant statistical methods which are used to build predictive models and conduct other analytic tasks using IBM SPSS Modeler. From ...

  1. Examining the impact of cell phone conversations on driving using meta-analytic techniques.

    Science.gov (United States)

    Horrey, William J; Wickens, Christopher D

    2006-01-01

    The performance costs associated with cell phone use while driving were assessed meta-analytically using standardized measures of effect size along five dimensions. There have been many studies on the impact of cell phone use on driving, showing some mixed findings. Twenty-three studies (contributing 47 analysis entries) met the appropriate conditions for the meta-analysis. The statistical results from each of these studies were converted into effect sizes and combined in the meta-analysis. Overall, there were clear costs to driving performance when drivers were engaged in cell phone conversations. However, subsequent analyses indicated that these costs were borne primarily by reaction time tasks, with far smaller costs associated with tracking (lane-keeping) performance. Hands-free and handheld phones revealed similar patterns of results for both measures of performance. Conversation tasks tended to show greater costs than did information-processing tasks (e.g., word games). There was a similar pattern of results for passenger and remote (cell phone) conversations. Finally, there were some small differences between simulator and field studies, though both exhibited costs in performance for cell phone use. We suggest that (a) there are significant costs to driver reactions to external hazards or events associated with cell phone use, (b) hands-free cell phones do not eliminate or substantially reduce these costs, and (c) different research methodologies or performance measures may underestimate these costs. Potential applications of this research include the assessment of performance costs attributable to different types of cell phones, cell phone conversations, experimental measures, or methodologies.

  2. Study on homogeneity of multielements for a stream sediment matrix material with nuclear analytical techniques

    International Nuclear Information System (INIS)

    Donghui Huang; Caijin Xiao; Bangfa Ni; Weizhi Tian; Pingsheng Wang; CunXiong Liu; Guiying Zhang; Hongchao Sun; Haiqing Zhang; Changjun Zhao; Yuanxun Zhang

    2012-01-01

    Taking advantages of nuclear analytical techniques (NATs) with non-destruction, multielement capability, small and estimable uncertainties over a wide range of sample sizes, the sampling behavior of multielements for a home-made natural matrix material was studied with sample sizes ranging from several hundred mg down to tenths ng, namely nine orders of magnitude, by a combination of three NATs, neutron activation analysis (NAA), proton induced X-ray emission (PIXE) and synchrotron radiation X-ray fluorescence (SR-XRF), in an effort to explore a procedure for the development of certified reference materials (CRMs) suitable for quality control of microanalysis. For accurately weighable sample sizes (>1 mg), sampling uncertainties for 13 elements were found to be less than 1% by INAA. For sample sizes unable to be accurately weighed (<1 mg), PIXE and SR-XRF were used, respectively. Sampling uncertainties were found to be less than 1% at sample sizes of tenth mg level for seven elements, and less than 10% on ng levels for three elements. Considering these three elements have satisfied homogeneity (sampling uncertainty less than 10%) at ng sample size level, any one of them can be served as a 'relative balance' in sampling behavior characterization of multielements on sample size levels larger than ng (e.g., μg level). On this basis, sampling uncertainties for nine elements were found to be less than 10% on μg sample size level by INAA. The results indicate that the matrix is eligible as a candidate of CRMs suitable for quality control of solid sampling microanalysis. (author)

  3. Novel analytical technique to study nucleobase influence on DNA strand breaks caused by direct ionizing radiation

    International Nuclear Information System (INIS)

    Watson, R.M.; Bernhard, W.A.

    2009-01-01

    Complete text of publication follows. Analysis of the reactions involved in the direct effect of ionizing radiation on DNA is crucial to assessing the risks related with exposure at low dose. The direct interaction of ionizing radiation with DNA initially results in free radicals situated on bases and the backbone, which eventually lead to stable end products that include strand breaks (sb) and free nucleobase release (fbr). The yields of these two products are thought to be related because ejection of an electron from the DNA backbone produces a radical cation that deprotonates to yield a neutral carbon-centered deoxyribose radical. These neutral radicals react when dissolved to produce one strand break and one free base each. Therefore fbr can be used as an indicator of sb. It is commonly presumed that that sb occur independent of the surrounding base context. However recent studies have indicated that a base may indeed have influence over the probability of sb at its backbone unit. In one such study, films prepared from 10- to 30-mer DNA duplexes were irradiated at RT under air using X-rays generated by a tungsten tube operated at 70 kV. The films were dissolved in nuclease free water and stored at 277 K. Unaltered free base release was measured using HPLC, and the yields determined for each base were not strictly proportionate to their presence in the DNA sequence. In fact, this study indicated that strand breaks may be influenced by a number of factors including position within the oligomer as well as the base and its base context. The current study involves further analysis of these factors; instead of using HPLC to separate and measure fbr, which is time consuming and expensive, a novel analytical technique is being used to determine the amount and ratio of fbr for each of the four bases. This technique involves separation of free bases from bulk DNA using filters followed by decomposition of the UV spectra of mixtures of bases at different pH. Decomposition

  4. A review on analytical techniques for natural convection investigation in a heated closed enclosure: Case study

    Directory of Open Access Journals (Sweden)

    Minea Alina Adriana

    2015-01-01

    Full Text Available The aim of this paper is to present a theoretical analysis of a few convection problems. The investigations were started from the geometry of a classic muffle manufactured furnace. During this analytical study, different methodologies have been carefully chosen in order to compare and evaluate the effects of applying different analytical methods of the convection heat transfer processes. In conclusion, even if there are available a lot of analytical methods, natural convection in enclosed enclosures can be studied correctly only with numerical analysis. Also, in this article is presented a case study on natural convection application in a closed heated enclosure.

  5. Performance Marketing with Google Analytics Strategies and Techniques for Maximizing Online ROI

    CERN Document Server

    Tonkin, Sebastian

    2010-01-01

    An unparalleled author trio shares valuable advice for using Google Analytics to achieve your business goals. Google Analytics is a free tool used by millions of Web site owners across the globe to track how visitors interact with their Web sites, where they arrive from, and which visitors drive the most revenue and sales leads. This book offers clear explanations of practical applications drawn from the real world. The author trio of Google Analytics veterans starts with a broad explanation of performance marketing and gets progressively more specific, closing with step-by-step analysis and a

  6. Orthogonal analytical methods for botanical standardization: Determination of green tea catechins by qNMR and LC-MS/MS

    OpenAIRE

    Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.

    2013-01-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development o...

  7. Use of nuclear and related analytical techniques in environmental research as exemplified by selected air pollution studies

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Jeran, Z.; Stropnik, B.; Svetina, M.

    2000-01-01

    Among nuclear and nuclear related analytical techniques, neutron activation analysis and X-ray fluorescence spectrometry proved to be particularly useful for environmental studies owing to their nondestructive character and multi element capability. This paper emphasizes their importance among other multielement analytical methods by discussing their specific role due to specific physics basis, quite different to other destructive non-nuclear methods, and by summarizing results obtained in several studies related to air pollution research, including analyses of airborne particulate matter, water samples, lichens and mosses. (author)

  8. Biomimetic polymers in analytical chemistry. Part 1: preparation and applications of MIP (Molecularly Imprinted Polymers) in extraction and separation techniques

    International Nuclear Information System (INIS)

    Tarley, Cesar Ricardo Teixeira; Sotomayor, Maria del Pilar Taboada; Kubota, Lauro Tatsuo

    2005-01-01

    MIPs are synthetic polymers that are used as biomimetic materials simulating the mechanism verified in natural entities such as antibodies and enzymes. Although MIPs have been successfully used as an outstanding tool for enhancing the selectivity or different analytical approaches, such as separation science and electrochemical and optical sensors, several parameters must be optimized during their synthesis. Therefore, the state-of-the-art of MIP production as well as the different polymerization methods are discussed. The potential selectivity of MIPs in the extraction and separation techniques focusing mainly on environmental, clinical and pharmaceutical samples as applications for analytical purposes is presented. (author)

  9. A pirólise como técnica analítica Pyrolysis as an analytical technique

    Directory of Open Access Journals (Sweden)

    Flaviano Oliveira Silvério

    2008-01-01

    Full Text Available In this paper historical aspects of analytical pyrolysis, the equipment used, the fundamentals and the mechanisms of pyrolysis of different polymeric materials are discussed. The latest work on analytical pyrolysis applied to various types of synthetic and natural samples is reviewed. Current applications of this technique that are discussed include identification of microorganisms, analysis of trace compounds by forensic laboratories, investigation of food and agricultural products, study of the chemical composition of wood, authentication and conservation of artworks, and the study of environmental and geochemical samples.

  10. Twelfth ISAS national symposium on analytical techniques for safety and sufficiency of natural resources/products: technical papers

    International Nuclear Information System (INIS)

    Padmanabhan, P.K.; Page, A.G.

    1997-02-01

    This volume contains the proceedings of the ISAS (Indian Society of Analytical Scientists) national symposium. The main thrust of the symposium was on new fuel cycle technologies relevant to thorium utilisation programmes. The technologies for different separation processes, techniques for measurements of various process parameters and highly sensitive analytical methods for the determination of the chemical constituents were among the other topics covered. Quality upgradation, standardisation of methods and validation of measurements which are integral parts of product evaluation were also discussed. Papers relevant to INIS are indexed separately

  11. Effects of Mountain Ultra-Marathon Running on ROS Production and Oxidative Damage by Micro-Invasive Analytic Techniques.

    Directory of Open Access Journals (Sweden)

    Simona Mrakic-Sposta

    Full Text Available Aiming to gain a detailed insight into the physiological mechanisms involved under extreme conditions, a group of experienced ultra-marathon runners, performing the mountain Tor des Géants® ultra-marathon: 330 km trail-run in Valle d'Aosta, 24000 m of positive and negative elevation changes, was monitored. ROS production rate, antioxidant capacity, oxidative damage and inflammation markers were assessed, adopting micro-invasive analytic techniques.Forty-six male athletes (45.04±8.75 yr, 72.6±8.4 kg, 1.76±0.05 m were tested. Capillary blood and urine were collected before (Pre-, in the middle (Middle- and immediately after (Post- Race. Samples were analyzed for: Reactive Oxygen Species (ROS production by Electron Paramagnetic Resonance; Antioxidant Capacity by Electrochemistry; oxidative damage (8-hydroxy-2-deoxy Guanosine: 8-OH-dG; 8-isoprostane: 8-isoPGF2α and nitric oxide metabolites by enzymatic assays; inflammatory biomarkers (plasma and urine interleukin-6: IL-6-P and IL-6-U by enzyme-linked immunosorbent assays (ELISA; Creatinine and Neopterin by HPLC, hematologic (lactate, glucose and hematocrit and urine parameters by standard analyses.Twenty-five athletes finished the race, while twenty-one dropped out of it. A significant increase (Post-Race vs Pre of the ROS production rate (2.20±0.27 vs 1.65±0.22 μmol.min-1, oxidative damage biomarkers (8-OH-dG: 6.32±2.38 vs 4.16±1.25 ng.mg-1 Creatinine and 8-isoPGF2α: 1404.0±518.30 vs 822.51±448.91 pg.mg-1Creatinine, inflammatory state (IL-6-P: 66.42±36.92 vs 1.29±0.54 pg.mL-1 and IL-6-U: 1.33±0.56 vs 0.71±0.17 pg.mL1 and lactate production (+190%, associated with a decrease of both antioxidant capacity (-7% and renal function (i.e. Creatinine level +76% was found.The used micro-invasive analytic methods allowed us to perform most of them before, during and immediately after the race directly in the field, by passing the need of storing and transporting samples for further analysis

  12. Recent Studies on the Speciation and Determination of Mercury in Different Environmental Matrices Using Various Analytical Techniques

    Directory of Open Access Journals (Sweden)

    Lakshmi Narayana Suvarapu

    2017-01-01

    Full Text Available This paper reviews the current research on the speciation and determination of mercury by various analytical techniques, including the atomic absorption spectrometry (AAS, voltammetry, inductively coupled plasma optical emission spectrometry (ICP-OES, ICP-mass spectrometry (MS, atomic fluorescence spectrometry (AFS, spectrophotometry, spectrofluorometry, and high performance liquid chromatography (HPLC. Approximately 96 research papers on the speciation and determination of mercury by various analytical instruments published in international journals since 2015 were reviewed. All analytical parameters, including the limits of detection, linearity range, quality assurance and control, applicability, and interfering ions, evaluated in the reviewed articles were tabulated. In this review, we found a lack of information in speciation studies of mercury in recent years. Another important conclusion from this review was that there were few studies regarding the concentration of mercury in the atmosphere.

  13. Technology and Technique Standards for Camera-Acquired Digital Dermatologic Images: A Systematic Review.

    Science.gov (United States)

    Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C

    2015-08-01

    Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed

  14. Standard guide for establishing a quality assurance program for analytical chemistry laboratories within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This guide covers the establishment of a quality assurance (QA) program for analytical chemistry laboratories within the nuclear industry. Reference to key elements of ANSI/ISO/ASQC Q9001, Quality Systems, provides guidance to the functional aspects of analytical laboratory operation. When implemented as recommended, the practices presented in this guide will provide a comprehensive QA program for the laboratory. The practices are grouped by functions, which constitute the basic elements of a laboratory QA program. 1.2 The essential, basic elements of a laboratory QA program appear in the following order: Section Organization 5 Quality Assurance Program 6 Training and Qualification 7 Procedures 8 Laboratory Records 9 Control of Records 10 Control of Procurement 11 Control of Measuring Equipment and Materials 12 Control of Measurements 13 Deficiencies and Corrective Actions 14

  15. Role of modern analytical techniques in the production of uranium metal

    International Nuclear Information System (INIS)

    Hareendran, K.N.; Roy, S.B.

    2009-01-01

    Production of nuclear grade uranium metal conforming to its stringent specification with respect to metallic and non metallic impurities necessitates implementation of a comprehensive quality control regime. Founding members of Uranium Metal Plant realised the importance of this aspect of metal production and a quality control laboratory was set up as part of the production plant. In the initial stages of its existence, the laboratory mainly catered to the process control analysis of the plant process samples and Spectroscopy Division and Analytical Division of BARC provided analysis of trace metallic impurities in the intermediates as well as in the product uranium metal. This laboratory also provided invaluable R and D support for the optimization of the process involving both calciothermy and magnesiothermy. Prior to 1985, analytical procedures used were limited to classical methods of analysis with minimal instrumental procedures. The first major analytical instrument, a Flame AAS was installed in 1985 and a beginning to the trace analysis was made. However during the last 15 years the Quality Control Section has modernized the analytical set up by acquiring appropriate instruments. Presently the facility has implemented a complete quality control and quality assurance program required to cover all aspects of uranium metal production viz analysis of raw materials, process samples, waste disposal samples and also determination of all the specification elements in uranium metal. The current analytical practices followed in QCS are presented here

  16. A Meta-Analytic Assessment of Empirical Differences in Standard Setting Procedures.

    Science.gov (United States)

    Bontempo, Brian D.; Marks, Casimer M.; Karabatsos, George

    Using meta-analysis, this research takes a look at studies included in a meta-analysis by R. Jaeger (1989) that compared the cut score set by one standard setting method with that set by another. This meta-analysis looks beyond Jaeger's studies to select 10 from the research literature. Each compared at least two types of standard setting method.…

  17. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis.

    Science.gov (United States)

    Young, Brian; King, Jonathan L; Budowle, Bruce; Armogida, Luigi

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described.

  18. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, Mitko

    2001-01-01

    The main goal of the Coordinated Research Project (No:9937/R0), entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear and Related Analytical Techniques', is to identify and validate site specific epiphytic plants for biomonitoring the atmospheric pollution in Jamaica using nuclear analytical techniques at the International Centre for Environmental and Nuclear Sciences (ICENS). The specific objectives for the second year of the project were: Development of HOP for sampling epiphytic plants in Jamaica; Sampling design and sample collection; Sample preparation and analysis; Development of an in-house SRM and participation in the NAT-5 inter-laboratory study; Data analysis and interpretation of the results; Development of a work plan of the third year of the project

  19. Workplace and occupational health: The first metal evaluation using nuclear and analytical techniques in the State of Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Barros Correia Menezes, M.A. de; Vilhena Schayer Sabino, C. de; Melo Mattos, S.V. de; Santos Filho, S.; Diniz, E.

    1998-01-01

    Belo Horizonte, the capital of the State of Minas Gerais and its neighbourhood are the second industrial center of Brazil, concentrating many industries in several areas mainly metal refining and transformation. There are no registers about the level of metal concentration in the environmental air in the industry, nor even of the level of workers' contamination. The overall objective of this Project is to make a survey of the exposures to metals related to occupational diseases in galvanizing industry, which is responsible for the majority of occurrences of occupational diseases. The survey will be accomplished using as bio-indicators hair, nails, blood, urine, and individual air filters. These matrixes will indicate the incorporation of metals and the exposure level. The analytical techniques that will be applied are the neutron activation joined to related non nuclear analytical techniques, such as atomic absorption. (author)

  20. A new multi-step technique with differential transform method for analytical solution of some nonlinear variable delay differential equations.

    Science.gov (United States)

    Benhammouda, Brahim; Vazquez-Leal, Hector

    2016-01-01

    This work presents an analytical solution of some nonlinear delay differential equations (DDEs) with variable delays. Such DDEs are difficult to treat numerically and cannot be solved by existing general purpose codes. A new method of steps combined with the differential transform method (DTM) is proposed as a powerful tool to solve these DDEs. This method reduces the DDEs to ordinary differential equations that are then solved by the DTM. Furthermore, we show that the solutions can be improved by Laplace-Padé resummation method. Two examples are presented to show the efficiency of the proposed technique. The main advantage of this technique is that it possesses a simple procedure based on a few straight forward steps and can be combined with any analytical method, other than the DTM, like the homotopy perturbation method.

  1. Quantification of process induced disorder in milled samples using different analytical techniques

    DEFF Research Database (Denmark)

    Zimper, Ulrike; Aaltonen, Jaakko; McGoverin, Cushla M.

    2012-01-01

    The aim of this study was to compare three different analytical methods to detect and quantify the amount of crystalline disorder/ amorphousness in two milled model drugs. X-ray powder diffraction (XRPD), differential scanning calorimetry (DSC) and Raman spectroscopy were used as analytical methods...... and indomethacin and simvastatin were chosen as the model compounds. These compounds partly converted from crystalline to disordered forms by milling. Partial least squares regression (PLS) was used to create calibration models for the XRPD and Raman data, which were subsequently used to quantify the milling...

  2. Achievements in resonance Raman spectroscopy review of a technique with a distinct analytical chemistry potential

    NARCIS (Netherlands)

    Efremov, E.V.; Ariese, F.; Gooijer, C.

    2008-01-01

    In an extended introduction, key aspects of resonance Raman spectroscopy (RRS) such as enhanced sensitivity and selectivity are briefly discussed in comparison with normal RS. The analytical potential is outlined. Then achievements in different fields of research are highlighted in four sections,

  3. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits. Part II

    International Nuclear Information System (INIS)

    MacLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. Many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration

  4. Capillary electromigration techniques for studying interactions between analytes and lipid dispersions

    Czech Academy of Sciences Publication Activity Database

    Wiedmer, S. K.; Lokajová, Jana

    2013-01-01

    Roč. 36, č. 1 (2013), s. 37-51 ISSN 1615-9306 Grant - others:Helsinki Research Funds(FI) 2105060 Institutional support: RVO:61388963 Keywords : electrokinetic chromatography * frontal analysis * liposome * microchips * partial filling Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.594, year: 2013

  5. Identification of purple dye from molluscs on an excavated textile by non-destructive analytical techniques

    DEFF Research Database (Denmark)

    Margariti, Christina; Protopapas, Stavros; Allen, Norman

    2013-01-01

    on samples from the find with the contemporary reference samples lead to the identification of purple dye as a dibromoindigo compound with the origin from molluscs of Murex trunculus species. The application of non-destructive analytical methods of investigation was successful in analysing dyes on excavated...

  6. Numerical-analytic technique for investigation of solutions of some nonlinear equations with Dirichlet conditions

    Czech Academy of Sciences Publication Activity Database

    Rontó, András; Rontó, M.; Holubová, G.; Nečesal, P.

    -, - (2011), s. 58 ISSN 1687-2770 Institutional research plan: CEZ:AV0Z10190503 Keywords : nonlinear boundary value problem * numerical-analytic method * Chebyshev interpolation polynomials Subject RIV: BA - General Mathematics Impact factor: 0.911, year: 2011 http://www.boundaryvalueproblems.com/content/2011/1/58/abstract

  7. Using Photocatalytic Oxidation and Analytic Techniques to Remediate Lab Wastewater Containing Methanol

    Science.gov (United States)

    Xiong, Qing; Luo, Mingliang; Bao, Xiaoming; Deng, Yurong; Qin, Song; Pu, Xuemei

    2018-01-01

    This experiment is dedicated to second-year and above undergraduates who are in their experimental session of the analytical chemistry course. Grouped students are required to use a TiO[subscript 2] photocatalytic oxidation process to treat the methanol-containing wastewater that resulted from their previous HPLC experiments. Students learn to…

  8. The earrings of Pancas treasure: Analytical study by X-ray based techniques – A first approach

    Energy Technology Data Exchange (ETDEWEB)

    Tissot, I., E-mail: isabel.tissot@archeofactu.pt [Archeofactu – Rua do Cerrado das Oliveiras, No. 14, 2°Dto., 2610-035 Alfragide (Portugal); Tissot, M., E-mail: matthias.tissot@archeofactu.pt [Archeofactu – Rua do Cerrado das Oliveiras, No. 14, 2°Dto., 2610-035 Alfragide (Portugal); Museu Nacional de Arqueologia – Praça do Império, 1400-206 Lisboa (Portugal); Manso, M., E-mail: marta974@gmail.com [Centro de Física Atómica da Universidade de Lisboa, Av., Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Alves, L.C., E-mail: luisa@cii.fc.ul.pt [IST/ITN, Univ. Técnica de Lisboa, E.N. 10, UFA-LFI, 2686-953 Sacavém (Portugal); Barreiros, M.A., E-mail: alexandra.barreiros@lneg.pt [LNEG, I.P., Estrada do Paço do Lumiar 22, 1649-038 Lisboa (Portugal); Marcelo, T., E-mail: teresa.marcelo@lneg.pt [LNEG, I.P., Estrada do Paço do Lumiar 22, 1649-038 Lisboa (Portugal); Carvalho, M.L., E-mail: lcalves@itn.pt [Centro de Física Atómica da Universidade de Lisboa, Av., Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Corregidor, V., E-mail: vicky.corregidor@itn.pt [IST/ITN, Univ. Técnica de Lisboa, E.N. 10, UFA-LFI, 2686-953 Sacavém (Portugal); Guerra, M.F., E-mail: maria.guerra@culture.gouv.fr [Centre de Recherche et de Restauration des Musées de France and UMR8220 CNRS - 14, quai François Mitterrand, 75001 Paris (France)

    2013-07-01

    The development of new metallurgical technologies in the Iberian Peninsula during the Iron Age is well represented by the 10 gold earrings from the treasure of Pancas. This work presents a first approach to the analytical study of these earrings and contributes to the construction of a typological evolution of the Iberian earrings. The manufacture techniques and the alloys composition were studied with three complementary X-ray spectroscopy techniques: portable EDXRF, μ-PIXE and SEM–EDS. The results were compared with earrings from the same and previous periods.

  9. Nuclear analytical techniques applied to the research on biokinetics of incorporated radionuclides for internal dosimetry

    International Nuclear Information System (INIS)

    Cantone, M.C.

    2005-01-01

    Full text: The presentation intends to discuss the contribution that techniques of analysis, based on activation analysis or mass spectrometry, can give to a very selected item of the protection against ionizing radiation: the biokinetics of relevant elements. The assessment of radiation dose to body tissues, following intakes of radionuclides in occupational, accidental exposures and environmental exposure in case of dispersion in the environment of radio contaminants of potential concerns, is essential to evaluate and manage the the related radiological risk, including the decisions and actions to be undertake. Internal dose is not directly measurable and the International Commission on Radiological Protection ICRP has developed models which describes the behavior of the substances in the human body, following their entry ways by inhalation or ingestion. Generally, all the available sources of information contribute in the modeling process, including studies on animals, use of chemical analogues and, obviously direct information on humans, which is definitely the preferred source on which a biokinetic model can be based. Biokinetic data on human are available for most of the biological essential elements (Fe, Zn, Cu, Se) and for some elements the metabolic behavior is well know due to their use in clinical application (I, Sr, Tc), moreover research is in progress for non-essential alpha emitters. However, for a number of element, including elements with radionuclide of radiological significance in case of environmental contamination (Ru, Zr, Ce, Te and Mo), human data are poor or missing and biokinetic parameters are essentially extrapolated from data on animals. The use of stable isotopes is a publicly well acceptable and ethically justifiable method, compared to the use of radioisotopes, when volunteer subjects are considered in the investigations. The design of the investigation is based on the double tracer approach: one isotope is given orally and a second

  10. Comparison between energy dispersive X-ray fluorescence and other nuclear analytical techniques in mineral exploration and mining

    International Nuclear Information System (INIS)

    Clayton, C.G.; Packer, T.W.; Wormald, M.R.

    1979-01-01

    At the present time there is an increasing awareness of the value and need for in-situ analytical methods throughout the general area of mineral exploration and mining. Of the alternative techniques, the measurement of natural gamma radiation is well established for uranium exploration and it is now being developed for sea-bed and lake-bed surveying. Energy dispersive X-ray fluorescence equipment is becoming more generally accepted, especially for mine control. Neutron techniques, for so long used routinely in oil well logging, are now being developed for a wide range of applications in all aspects of exploration and mining. It is believed that these techniques will result in major applications in the future. The present paper compares the principal characteristics of energy dispersive X-ray fluorescence and neutron techniques in particular, with special emphasis being given to those factors which affect the accuracy of analytical content; such as elemental resolution, matrix effects, material heterogeneity and neutron transport. A generalised comparison between the techniques is difficult to achieve because of the different nature of radiation interactions, but a range of applications is described and these show the complementary nature of the methods and point to the areas for more active development in the future. (author)

  11. A REVIEW ON THE ANALYTICAL TECHNIQUES USED FOR THE DETERMINATION OF PARACETAMOL IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS

    Directory of Open Access Journals (Sweden)

    Aisha Noreen

    2016-12-01

    Full Text Available Paracetamol (PM is an active metabolite of phenacetin and belongs to p-aminophenol derivatives. It is also termed as acetaminophen. PM is one of the non-steroidal anti-inflammatory drugs (NSAIDs which is used as an analgesic and antipyretic agent. It is an OTC drug and is used as a common household analgesic. It is not used as a substitute of aspirin or any other NSAIDs. It is a weak cyclooxygenase (COX 1 and 2 inhibitor but may inhibit COX-3 in the central nervous system. Many analytical techniques have been used for the assay of PM in pharmaceutical preparations and biological fluids. These techniques include spectrometry, chromatography, spectrofluorimetry, chemiluminescence, electrochemical techniques, flow injection spectrometry and chronoamperometry. In many pharmaceutical preparations PM is also used in combination with other drugs and these techniques have also been used for their simultaneous determination. A detailed review of various analytical techniques used for the assay of PM has been carried out which would be of great help to the chemists and pharmacists involved in the analysis and quality control of drugs.

  12. [Preparation of sub-standard samples and XRF analytical method of powder non-metallic minerals].

    Science.gov (United States)

    Kong, Qin; Chen, Lei; Wang, Ling

    2012-05-01

    In order to solve the problem that standard samples of non-metallic minerals are not satisfactory in practical work by X-ray fluorescence spectrometer (XRF) analysis with pressed powder pellet, a method was studied how to make sub-standard samples according to standard samples of non-metallic minerals and to determine how they can adapt to analysis of mineral powder samples, taking the K-feldspar ore in Ebian-Wudu, Sichuan as an example. Based on the characteristic analysis of K-feldspar ore and the standard samples by X-ray diffraction (XRD) and chemical methods, combined with the principle of the same or similar between the sub-standard samples and unknown samples, the experiment developed the method of preparation of sub-standard samples: both of the two samples above mentioned should have the same kind of minerals and the similar chemical components, adapt mineral processing, and benefit making working curve. Under the optimum experimental conditions, a method for determination of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, K2O and Na2O of K-feldspar ore by XRF was established. Thedetermination results are in good agreement with classical chemical methods, which indicates that this method was accurate.

  13. Terracotta polychrome sculptures examined before and after their conservation work: contributions from non-invasive in situ analytical techniques.

    Science.gov (United States)

    Colombo, C; Bevilacqua, F; Brambilla, L; Conti, C; Realini, M; Striova, J; Zerbi, G

    2011-08-01

    The potential of non-invasive in situ analytical techniques such as portable Raman, portable X-ray fluorescence, portable optical microscope and fibre optics reflectance spectroscopy has been shown studying painted layers of Renaissance terracotta polychrome sculptures belonging to the statuary of Santo Sepolcro Church in Milan. The results obtained allowed pointing out the contribution of these techniques to the compositional diagnostic, providing complete information, in some cases, better than micro-destructive techniques, on the kind of pigments used on the external painted layers. Moreover, a comparison with the results obtained before the last conservation work (2009) with micro-destructive techniques allowed ascertaining the removal of the external painted layers during the conservation operations.

  14. Analytics for Cyber Network Defense

    Energy Technology Data Exchange (ETDEWEB)

    Plantenga, Todd. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Kolda, Tamara Gibson [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2011-06-01

    This report provides a brief survey of analytics tools considered relevant to cyber network defense (CND). Ideas and tools come from elds such as statistics, data mining, and knowledge discovery. Some analytics are considered standard mathematical or statistical techniques, while others re ect current research directions. In all cases the report attempts to explain the relevance to CND with brief examples.

  15. Mathematical modelling of two-analyte sequential determinations by flow-injection sandwich-techniques

    International Nuclear Information System (INIS)

    Montesinos, J.L.; Poch, M.; Alonso, J.; Valle, M. del; Lima, J.L.F.C.

    1991-01-01

    Results obtained in the evaluation of a mathematical model for flow-injection sandwich systems, in which the sample is inserted between two different carrier solutions with the aid of an eight-way injection valve, are presented. The model considers the system as a tubular reactor with axially dispersed plug flow, where chemical kinetics have been included. Only a minimum of parameters are needed for the model: the dispersion coefficients, which are obtained from experimental correlations for the different hydrodynamic conditions, and the rate constants, which are determined by univariate optimization. The behaviour of the model, when applied to the case of one analyte and one reagent, was evaluated for the enzymatic determinations of glucose and glycerol. The case of two analytes determined with two reagents was also studied in the combined determination of glucose and glycerol. Experimental profiles were compared with the simulated peaks and showed good agreement. (author). 20 refs.; 11 figs.; 2 tabs

  16. Mathematical modelling of two-analyte sequential determinations by flow-injection sandwich-techniques

    Energy Technology Data Exchange (ETDEWEB)

    Montesinos, J.L.; Poch, M. (Universitat Autonoma de Barcelona (Spain). Departament de Quimica, Unitat d' Enginyera Quimica); Alonso, J.; Valle, M. del (Universitat Autonoma de Barcelona (Spain). Departament de Quimica, Unitat de Quimica Analitica); Lima, J.L.F.C. (Universidade de Porto (Portugal). Faculdade de Farmacia, Departamento de Quimica Fisica)

    1991-11-20

    Results obtained in the evaluation of a mathematical model for flow-injection sandwich systems, in which the sample is inserted between two different carrier solutions with the aid of an eight-way injection valve, are presented. The model considers the system as a tubular reactor with axially dispersed plug flow, where chemical kinetics have been included. Only a minimum of parameters are needed for the model: the dispersion coefficients, which are obtained from experimental correlations for the different hydrodynamic conditions, and the rate constants, which are determined by univariate optimization. The behaviour of the model, when applied to the case of one analyte and one reagent, was evaluated for the enzymatic determinations of glucose and glycerol. The case of two analytes determined with two reagents was also studied in the combined determination of glucose and glycerol. Experimental profiles were compared with the simulated peaks and showed good agreement. (author). 20 refs.; 11 figs.; 2 tabs.

  17. Laboratory Techniques in Geology: Embedding Analytical Methods into the Undergraduate Curriculum

    Science.gov (United States)

    Baedke, S. J.; Johnson, E. A.; Kearns, L. E.; Mazza, S. E.; Gazel, E.

    2014-12-01

    Paid summer REU experiences successfully engage undergraduate students in research and encourage them to continue to graduate school and scientific careers. However these programs only accommodate a limited number of students due to funding constraints, faculty time commitments, and limited access to needed instrumentation. At JMU, the Department of Geology and Environmental Science has embedded undergraduate research into the curriculum. Each student fulfilling a BS in Geology or a BA in Earth Science completes 3 credits of research, including a 1-credit course on scientific communication, 2 credits of research or internship, followed by a presentation of that research. Our department has successfully acquired many analytical instruments and now has an XRD, SEM/EDS, FTIR, handheld Raman, AA, ion chromatograph, and an IRMS. To give as many students as possible an overview to the scientific uses and operation methods for these instruments, we revived a laboratory methods course that includes theory and practical use of instrumentation at JMU, plus XRF sample preparation and analysis training at Virginia Tech during a 1-day field trip. In addition to practical training, projects included analytical concepts such as evaluating analytical vs. natural uncertainty, determining error on multiple measurements, signal-to-noise ratio, and evaluating data quality. State funding through the 4-VA program helped pay for analytical supplies and support for students to complete research projects over the summer or during the next academic year using instrumentation from the course. This course exemplifies an alternative path to broadening participation in undergraduate research and creating stronger partnerships between PUI's and research universities.

  18. Analytical techniques for characterization of raw materials in cell culture media

    OpenAIRE

    Sharma, Chandana; Drew, Barry; Head, Kevin; Pusuluri, Rani; Caple, Matthew V

    2011-01-01

    Abstract Raw materials are a critical part of any cell culture medium; therefore, it is of utmost importance to understand and characterize them for high-quality product. The raw material characterization (RMC) program at SAFC focuses on individual screening of raw materials both analytically and biologically. The goal of the program is to develop the best-in-class knowledge base of the raw materials used in SAFC’s media formulations and their impact on performance of products.

  19. Short-Term Forecasting Models for Photovoltaic Plants: Analytical versus Soft-Computing Techniques

    OpenAIRE

    Monteiro, Claudio; Fernandez-Jimenez, L. Alfredo; Ramirez-Rosado, Ignacio J.; Muñoz-Jimenez, Andres; Lara-Santillan, Pedro M.

    2013-01-01

    We present and compare two short-term statistical forecasting models for hourly average electric power production forecasts of photovoltaic (PV) plants: the analytical PV power forecasting model (APVF) and the multiplayer perceptron PV forecasting model (MPVF). Both models use forecasts from numerical weather prediction (NWP) tools at the location of the PV plant as well as the past recorded values of PV hourly electric power production. The APVF model consists of an original modeling for adj...

  20. The role of nuclear analytical techniques in the study of aqueous corrosion of glasses

    International Nuclear Information System (INIS)

    Trocellier, P.

    1984-01-01

    Direct observation of resonant nuclear reactions, backscattering spectrometry and X ray microanalysis with a nuclear microprobe were used to determine elementary depth profiles in the near surface region of leached glasses. Some computing programs required to interpretate the analytical information detected were built. Experimental conditions to characterize glass samples without secondary effects were defined; and the influence of some leaching parameters was studied to describe the first stages of aqueous corrosion of borosilicate glasses [fr

  1. Are Randomized Controlled Trials the (G)old Standard? From Clinical Intelligence to Prescriptive Analytics

    Science.gov (United States)

    2016-01-01

    Despite the accelerating pace of scientific discovery, the current clinical research enterprise does not sufficiently address pressing clinical questions. Given the constraints on clinical trials, for a majority of clinical questions, the only relevant data available to aid in decision making are based on observation and experience. Our purpose here is 3-fold. First, we describe the classic context of medical research guided by Poppers’ scientific epistemology of “falsificationism.” Second, we discuss challenges and shortcomings of randomized controlled trials and present the potential of observational studies based on big data. Third, we cover several obstacles related to the use of observational (retrospective) data in clinical studies. We conclude that randomized controlled trials are not at risk for extinction, but innovations in statistics, machine learning, and big data analytics may generate a completely new ecosystem for exploration and validation. PMID:27383622

  2. Ficus deltoidea Standardization: Analytical Methods for Bioactive Markers in Deltozide Tablet 200 MG

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Zainah Adam; Rosniza Razali

    2016-01-01

    Standardization of herbal materials based on their chemical and biological profile is an important prerequisite for development of herbal product. The phyto pharmaceutical product that has been developed by Medical Technology Division, Malaysian Nuclear Agency is DELTOZIDE TABLET 200 MG containing 200 mg of spray-dried aqueous extract of Ficus deltoidea var kunstleri leaf as the active ingredient. Ficus deltoidea Jack or locally known as Mas Cotek is a South East Asian native plant traditionally used to treat several diseases. Pharmacological data showed that this plant exhibited good antioxidant, anti-diabetic and anti-inflammatory properties. It is important to establish the chemical profiles and determine the phytochemicals content of this plant as it is popularly used in traditional medicines. Thus, the present study reports on the comprehensive phytochemicals evaluation of bioactive markers from this extract for the development of DELTOZIDE TABLET 200 MG . Characterization of extract using LCMS/ MS Triple TOF System showed the presence of major constituents representing vitexin, isovitexin, gallic acid, catechinic, api genin, epicatechin and caffeoylquinic acid along with other minor constituents. The extract was standardized by ultra-high performance liquid chromatography (UHPLC) using two pharmacologically active markers, vitexin and isovitexin. Furthermore, qualitative determination of phytochemicals showed the presence of important phyto-constituents namely anthraquinones, terpenoids, flavonoids, tannins, phlobatannins, alkaloids, saponins, cardiac glycosides, steroids and phenols in the aqueous extract of Ficus deltoidea. Quantitative determination of phytochemicals revealed that the amount of total phenolic content (TPC; Gallic acid as standard) and total flavonoid content (TFC; Quercetin as standard) were 126.67±3.98 mg GAE/ g extract and 9.08±0.36 mg QE/ g extract respectively. The generated data provides some explanation for its wide usage in

  3. Earth Science Data Analytics: Bridging Tools and Techniques with the Co-Analysis of Large, Heterogeneous Datasets

    Science.gov (United States)

    Kempler, Steve; Mathews, Tiffany

    2016-01-01

    The continuum of ever-evolving data management systems affords great opportunities to the enhancement of knowledge and facilitation of science research. To take advantage of these opportunities, it is essential to understand and develop methods that enable data relationships to be examined and the information to be manipulated. This presentation describes the efforts of the Earth Science Information Partners (ESIP) Federation Earth Science Data Analytics (ESDA) Cluster to understand, define, and facilitate the implementation of ESDA to advance science research. As a result of the void of Earth science data analytics publication material, the cluster has defined ESDA along with 10 goals to set the framework for a common understanding of tools and techniques that are available and still needed to support ESDA.

  4. Analytical techniques for in-line/on-line monitoring of uranium and plutonium in process solutions : a brief literature survey

    International Nuclear Information System (INIS)

    Marathe, S.G.; Sood, D.D.

    1991-01-01

    In-line/on-line monitoring of various parameters such as uranium-plutonium-fission product concentration, acidity, density etc. plays an important role in quickly understanding the efficiency of processes in a reprocessing plant. Efforts in studying and installation of such analytical instruments are going on since more than three decades with adaptation of newer methods and technologies. A review on the developement of in-line analytical instrumentation was carried out in this laboratory about two decades ago. This report presents a very short literature survey of the work in the last two decades. The report includes an outline of principles of the main techniques employed in the in-line/on-line monitoring. (author). 77 refs., 6 tabs

  5. Meeting report on third regional workshop on quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    2002-01-01

    Over the last 20 years, the Agency, through its Technical Co-operation Programme, has helped to establish many nuclear analytical laboratories in nuclear institutions and universities of Member States. The project RER/2/004 has been approved in 1999 for a period of two years aiming at the implementation of a comprehensive QA/QC protocol in laboratories of Member States following the ISO guide 17025. The project involved 13 laboratories from 12 countries. This report presents the project setup, intended outputs and outcomes, achievements and conclusions. It also contains reports from participating laboratories. Each of the reports has been provided with an abstract and indexed separately

  6. Analytical and Numerical Tooth Contact Analysis (TCA of Standard and Modified Involute Profile Spur Gear

    Directory of Open Access Journals (Sweden)

    Nassear Rasheid Hmoad

    2016-03-01

    Full Text Available Among all the common mechanical transmission elements, gears still playing the most dominant role especially in the heavy duty works offering extraordinary performance under extreme conditions and that the cause behind the extensive researches concentrating on the enhancement of its durability to do its job as well as possible. Contact stress distribution within the teeth domain is considered as one of the most effective parameters characterizing gear life, performance, efficiency, and application so that it has been well sought for formal gear profiles and paid a lot of attention for moderate tooth shapes. The aim of this work is to investigate the effect of pressure angle, speed ratio, and correction factor on the maximum contact and bending stress value and principal stresses distribution for symmetric and asymmetric spur gear. The analytical investigation adopted Hertz equations to find the contact stress value, distribution, and the contact zone width while the numerical part depends on Ansys software version 15, as a FE solver with Lagrange and penalty contact algorithm. The most fruitful points to be noticed are that the increasing of pressure angle and speed ratio trends to minimize all the induced stresses for the classical gears and the altered teeth shape with larger loaded side pressure angle than the unloaded side one behave better than the symmetric teeth concerning the stress reduction.

  7. Are we Breathing Clean Air in Metro Manila? (Nuclear and Related Analytical Techniques and Receptor Modeling Revealing the Real Score)

    International Nuclear Information System (INIS)

    Pabroa, Preciosa Corazon B.

    2015-01-01

    Air Particulate matter (APM) is a mixture of different pollutant sources which can be of anthropogenic and/or natural origin, of which the size of great concern with regard to adverse effects on human health are generally less than 10μm (Referred to as PM10). Identification and apportionment of pollutant sources is important to be able to have better understanding of prevailing conditions in the area and thus better air quality management can be applied. APM (PM10) at sampling sites in Metro Manila (Philippines) has been monitored since 1998 for the primary purpose of source identification and source apportionment. APM samples (fractionated into coarse (PM2.5-10) and fine (PM2.5) fractions) were collected using a Gent air sampler. Particulate mass was determined by gravimetry and black carbon by reflectometry organic carbon/elemental carbon by thermal optical reflectance. Elemental concentrations were determined using nuclear and related analytical techniques such as the particle-induced x-ray emission (PIXE) spectrometry and x-ray fluorescence (XRF) spectrometry. Source apportionment of fine air particles was done using PMF2. Result show PM10 levels to be in compliance to the Philippine 1-year guideline value of 60 μg m“-“3 but in exceedance of the US EPA 1-year standard of 15 μg m“-“3 and the WHO 1-year guideline value of 10 μg m“-“3. Annual mean % Fine BC levels range from 33% to 59%, but individual points can reach up to more than 80% of the PM2.5 levels. Pb level in the fine fraction exhibit decreasing trend coinciding with the introduction of unleaded-gasoline starting in 1998 and the eventual phase-out of the use of leaded-gasoline in 2001. Six air pollution sources have been identified in the fine fraction with vehicular emissions making up the bulk at about 50%. Other sources are smoke, secondary S, fine soil and industry. Addressing problems regarding traffic-related activities can greatly reduce the fine particulate pollution problems

  8. Evaluation and standardisation of fast analytical techniques for destructive radwaste control

    International Nuclear Information System (INIS)

    De Simone, A.; Troiani, F.

    2001-01-01

    The document describes the work programme carried out by the Laboratorio Nazionale per la 'Caratterizzazione dei Refit Radioattivi', in the frame of the European research project Destructive Radwaste Control. The main tasks of the research work were the evaluation of fast sample pre-treatment procedures and the development of chromatographic methods coupled to fast nuclide detection by Liquid Scintillation Counting. In order to test the High Performance Ion Chromatograph (HPIC) coupled to the Liquid Scintillation Counter (LSC) on high salt content solutions, synthetic cement solutions have been prepared and spiked with several β-emitters hard to be measured with non-destructive analyses, along with other radionuclides important for the determination of the radiological inventory in radwastes. As the validation tests for the new analytical methods involved the manipulation of radioactive solutions, a remote area for HPIC-LSC apparatus has been designed and performed, in order to operate in safe conditions. According to the research programme, fast analytical methods for the chemical separation and radionuclide detection of the radioactive elements of interest, have been developed and qualified. From the results of the work, some protocols of analysis have been defined: they contain all information about operative conditions for HPIC-LSC apparatus, field of applicability, chemical and radioactive detection limits [it

  9. Applied research on air pollution using nuclear-related analytical techniques. Report on the second research co-ordination meeting

    International Nuclear Information System (INIS)

    1995-01-01

    A co-ordinated research programme (CRP) on applied research on air pollution using nuclear-related techniques is a global CRP which started in 1992, and is scheduled to run until early 1997. The purpose of this CRP is to promote the use of nuclear analytical techniques in air pollution studies, e.g. NAA, XRF, and PIXE for the analysis of toxic and other trace elements in air particulate matter. The main purposes of the core programme are i) to support the use of nuclear and nuclear-related analytical techniques for research and monitoring studies on air pollution, ii) to identify major sources of air pollution affecting each of the participating countries with particular reference to toxic heavy metals, and iii) to obtain comparative data on pollution levels in areas of high pollution (e.g. a city centre or a populated area downwind of a large pollution source) and low pollution (e.g. rural area). This document reports the discussions held during the second Research Co-ordination Meeting (RCM) for the CRP which took place at ANSTO in Menai, Australia. (author)

  10. Reliable screening of various foodstuffs with respect to their irradiation status: A comparative study of different analytical techniques

    International Nuclear Information System (INIS)

    Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho

    2013-01-01

    Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0–10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700–5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods. - Highlights: • Detection of irradiated food is important to enforce the applied regulations. • Gamma-irradiated spices were investigated to confirm their irradiation status. • Screening techniques such as PSL, DEFT/APC, and E-nose were tested. • Specificity and potential applications of screening techniques were evaluated. • The screening results were confirmed by promising thermoluminescence technique

  11. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    Science.gov (United States)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  12. Analytical Expressions of the Efficiency of Standard and High Contact Ratio Involute Spur Gears

    Directory of Open Access Journals (Sweden)

    Miguel Pleguezuelos

    2013-01-01

    Full Text Available Simple, traditional methods for computation of the efficiency of spur gears are based on the hypotheses of constant friction coefficient and uniform load sharing along the path of contact. However, none of them is accurate. The friction coefficient is variable along the path of contact, though average values can be often considered for preliminary calculations. Nevertheless, the nonuniform load sharing produced by the changing rigidity of the pair of teeth has significant influence on the friction losses, due to the different relative sliding at any contact point. In previous works, the authors obtained a nonuniform model of load distribution based on the minimum elastic potential criterion, which was applied to compute the efficiency of standard gears. In this work, this model of load sharing is applied to study the efficiency of both standard and high contact ratio involute spur gears (with contact ratio between 1 and 2 and greater than 2, resp.. Approximate expressions for the friction power losses and for the efficiency are presented assuming the friction coefficient to be constant along the path of contact. A study of the influence of some transmission parameters (as the gear ratio, pressure angle, etc. on the efficiency is also presented.

  13. Applications of nuclear analytical techniques in human nutrition research as exemplified by research programmes of the International Atomic Energy Agency

    International Nuclear Information System (INIS)

    Parr, R.M.

    1987-01-01

    In human nutrition research, nuclear analytical techniques, particularly neutron activation analysis (NAA), are used mainly for the in vitro study of trace elements. According to work sponsored by the IAEA, up to 15 trace elements and 5 minor elements of nutritional interest may be determined in biological materials by NAA with good accuracy and precision. A programme is described in which NAA was used for the determination of 14 trace elements and one minor element in human milk. NAA also plays an important role in the certification of reference materials for nutritional studies. (author) 17 refs.; 6 tables

  14. Integrated analytical techniques with high sensitivity for studying brain translocation and potential impairment induced by intranasally instilled copper nanoparticles.

    Science.gov (United States)

    Bai, Ru; Zhang, Lili; Liu, Ying; Li, Bai; Wang, Liming; Wang, Peng; Autrup, Herman; Beer, Christiane; Chen, Chunying

    2014-04-07

    Health impacts of inhalation exposure to engineered nanomaterials have attracted increasing attention. In this paper, integrated analytical techniques with high sensitivity were used to study the brain translocation and potential impairment induced by intranasally instilled copper nanoparticles (CuNPs). Mice were exposed to CuNPs in three doses (1, 10, 40 mg/kg bw). The body weight of mice decreased significantly in the 10 and 40 mg/kg group (ptechniques for systematic investigations is a promising direction to better understand the biological activities of nanomaterials. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Atomic and Nuclear Analytical Methods XRF, Mössbauer, XPS, NAA and Ion-Beam Spectroscopic Techniques

    CERN Document Server

    Verma, H R

    2007-01-01

    This book is a blend of analytical methods based on the phenomenon of atomic and nuclear physics. It comprises comprehensive presentations about X-ray Fluorescence (XRF), Mössbauer Spectroscopy (MS), X-ray Photoelectron Spectroscopy (XPS), Neutron- Activation Analysis (NAA), Particle Induced X-ray Emission Analysis (PIXE), Rutherford Backscattering Analysis (RBS), Elastic Recoil Detection (ERD), Nuclear Reaction Analysis (NRA), Particle Induced Gamma-ray Emission Analysis (PIGE), and Accelerator Mass Spectrometry (AMS). These techniques are commonly applied in the fields of medicine, biology, environmental studies, archaeology or geology et al. and pursued in major international research laboratories.

  16. Achievements and advantages of participation in the IAEA project RER 002/004/1999-2001 'QA/QC of Nuclear Analytical Techniques'

    International Nuclear Information System (INIS)

    Vata, Ion; Cincu, Em.

    2002-01-01

    The National Institute for Physics and Engineering 'Horia Hulubei' (IFIN-HH) decided in the late 1990s to start applying nuclear techniques in economy and social life on a routine scale; reaching this goal implied achieving first-rate analytical performances and complying with the QA/QC requirements, as detailed in the ISO 17025. The IAEA Project appeared in 1999 as the best opportunity and tool for our specialists to become familiar with the standard requirements and begin to implement them in their operations, thus further enabling them to apply for accreditation according to the international criteria. This report outlines the experience gained from the participation in the project. The accomplishments of the project are presented and the main difficulties are identified

  17. Analytical-scale separations of lanthanides : a review of techniques and fundamentals.

    Energy Technology Data Exchange (ETDEWEB)

    Nash, K. L.; Jensen, M. P.

    1999-10-27

    Separations chemistry is at the heart of most analytical procedures to determine the rare earth content of both man-made and naturally occurring materials. Such procedures are widely used in mineral exploration, fundamental geology and geochemistry, material science, and in the nuclear industry. Chromatographic methods that rely on aqueous solutions containing complexing agents sensitive to the lanthanide cationic radius and cation-exchange phase transfer reactions (using a variety of different solid media) have enjoyed the greatest success for these procedures. In this report, they will briefly summarize the most important methods for completing such analyses. they consider in some detail the basic aqueous (and two-phase) solution chemistry that accounts for separations that work well and offer explanations for why others are less successful.

  18. Modern analytical techniques in the assessment of the authenticity of Serbian honey.

    Science.gov (United States)

    Milojković Opsenica, Dušanka; Lušić, Dražen; Tešić, Živoslav

    2015-12-01

    Food authenticity in a broader sense means fulfilling chemical and physical criteria prescribed by the proposed legislation. In the case of honey authenticity, two aspects are of major concern: the manufacturing process and the labelling of final products in terms of their geographical and botanical origin. A reliable assessment of honey authenticity has been a longterm preoccupation of chemists-analysts and it usually involves the use of several criteria and chemical markers, as well as a combination of analytical and statistical (chemometric) methods. This paper provides an overview of different criteria and modern methods for the assessment of honey authenticity in the case of a statistically significant number of authentic honey samples of several botanical types from various regions of Serbia.

  19. New digital demodulator with matched filters and curve segmentation techniques for BFSK demodulation: Analytical description

    Directory of Open Access Journals (Sweden)

    Jorge Torres Gómez

    2015-09-01

    Full Text Available The present article relates in general to digital demodulation of Binary Frequency Shift Keying (BFSK. The objective of the present research is to obtain a new processing method for demodulating BFSK-signals in order to reduce hardware complexity in comparison with other methods reported. The solution proposed here makes use of the matched filter theory and curve segmentation algorithms. This paper describes the integration and configuration of a Sampler Correlator and curve segmentation blocks in order to obtain a digital receiver for a proper demodulation of the received signal. The proposed solution is shown to strongly reduce hardware complexity. In this part a presentation of the proposed solution regarding the analytical expressions is addressed. The paper covers in detail the elements needed for properly configuring the system. In a second part it is presented the implementation of the system for FPGA technology and the simulation results in order to validate the overall performance.

  20. Analytical-scale separations of lanthanides : a review of techniques and fundamentals

    International Nuclear Information System (INIS)

    Nash, K. L.; Jensen, M. P.

    1999-01-01

    Separations chemistry is at the heart of most analytical procedures to determine the rare earth content of both man-made and naturally occurring materials. Such procedures are widely used in mineral exploration, fundamental geology and geochemistry, material science, and in the nuclear industry. Chromatographic methods that rely on aqueous solutions containing complexing agents sensitive to the lanthanide cationic radius and cation-exchange phase transfer reactions (using a variety of different solid media) have enjoyed the greatest success for these procedures. In this report, they will briefly summarize the most important methods for completing such analyses. they consider in some detail the basic aqueous (and two-phase) solution chemistry that accounts for separations that work well and offer explanations for why others are less successful

  1. Kinetic calculations for miniature neutron source reactor using analytical and numerical techniques

    International Nuclear Information System (INIS)

    Ampomah-Amoako, E.

    2008-06-01

    The analytical methods, step change in reactivity and ramp change in reactivity as well as numerical methods, fixed point iteration and Runge Kutta-gill were used to simulate the initial build up of neutrons in a miniature neutron source reactor with and without temperature feedback effect. The methods were modified to include photo neutron concentration. PARET 7.3 was used to simulate the transients behaviour of Ghana Research Reactor-1. The PARET code was capable of simulating the transients for 2.1 mk and 4 mk insertions of reactivity with peak powers of 49.87 kW and 92.34 kW, respectively. PARET code however failed to simulate 6.71 mk of reactivity which was predicted by Akaho et al through TEMPFED. (au)

  2. Study on bird's & insect's wing aerodynamics and comparison of its analytical value with standard airfoil

    Science.gov (United States)

    Ali, Md. Nesar; Alam, Mahbubul; Hossain, Md. Abed; Ahmed, Md. Imteaz

    2017-06-01

    by several species of birds. Hovering, which is generating only lift through flapping alone rather than as a product of thrust, demands a lot of energy. On the other hand, for practical knowledge we also fabricate the various bird's, insect's & fighter jet wing by using random value of parameter & test those airfoil in wind tunnel. Finally for comparison & achieving analytical knowledge we also test those airfoil model in various simulation software.

  3. Echinacea standardization: analytical methods for phenolic compounds and typical levels in medicinal species.

    Science.gov (United States)

    Perry, N B; Burgess, E J; Glennie, V L

    2001-04-01

    A proposed standard extraction and HPLC analysis method has been used to measure typical levels of various phenolic compounds in the medicinally used Echinacea species. Chicoric acid was the main phenolic in E. purpurea roots (mean 2.27% summer, 1.68% autumn) and tops (2.02% summer, 0.52% autumn), and echinacoside was the main phenolic in E. angustifolia (1.04%) and E. pallida roots (0.34%). Caftaric acid was the other main phenolic compound in E. purpurea roots (0.40% summer, 0.35% autumn) and tops (0.82% summer, 0.18% autumn), and cynarin was a characteristic component of E. angustifolia roots (0.12%). Enzymatic browning during extraction could reduce the measured levels of phenolic compounds by >50%. Colorimetric analyses for total phenolics correlated well with the HPLC results for E. purpurea and E. angustifolia, but the colorimetric method gave higher values.

  4. A comparison between two lateral cephalometry techniques (standard and natural head position

    Directory of Open Access Journals (Sweden)

    Hedayati Z. Assistant Professor. Sang S. DMD

    2003-06-01

    Full Text Available Statement of Problem: Cephalometric findings are of high importance in making decision about orthodontic treatment plans and orthognathic surgeries. Natural head position (NHP is considered as a useful and exact radiographic technique."nAim: The aim of the present study was to compare two techniques, namely Standard and NHP, in lateral"ncephalometry."nMaterials and Methods: In this cross- sectional study, performed in Shiraz. 138 randomly selected students {70 males .and 68 females, age ranging from (13-15. were evaluated clinically and radiographically. None of them had a history of orthodontic treatment, head and face fracture or surgical operations. Lateral cephalograms were taken in both standard and natural head position techniques, for each student. For statistical analysis, l-lest for paired samples, was done."nResults: This study showed that in anterior-posterior dimension, among angles with significant differences in two techniques, those of standard one were more reliable, whereas in vertical dimension."nstatistical differences showed natural technique as more useful one."nConclusion: Due to the fact that natural cephalometry requires more patient cooperation, more time and a higher complex technique, it is not suggested, except when different clinical and cepholomeiric findings are observed.

  5. Laryngeal mask airway insertion in children: comparison between rotational, lateral and standard technique.

    Science.gov (United States)

    Ghai, Babita; Makkar, Jeetinder Kaur; Bhardwaj, Neerja; Wig, Jyotsna

    2008-04-01

    The purpose of the study was to compare the success and ease of insertion of three techniques of laryngeal mask airway (LMA) insertion; the standard Brain technique, a lateral technique with cuff partially inflated and a rotational technique with cuff partially inflated. One hundred and sixty-eight ASA I and II children aged 6 months to 6 years undergoing short elective surgical procedures lasting 40-60 min were included in the study. A standard anesthesia protocol was followed for all patients. Patients were randomly allocated into one of the three groups i.e. standard (S), rotational (R) and lateral (L). The primary outcome measure of the study was success rate at the first attempt using three techniques of LMA insertion. Secondary outcomes measures studied were overall success rate, time before successful LMA insertion, complications and maneuvers used to relieve airway obstruction. Successful insertion at the first attempt was significantly higher in group R (96%) compared with group L (84%) and group S (80%) (P = 0.03). Overall success rate (i.e. successful insertion with two attempts) was 100% for group R, 93% for group L and 87% for group S (P = 0.03). Time for successful insertion was significantly lower in group R compared with group L and S (P insertion and lowest incidence of complications and could be the technique of first choice for LMA insertion in pediatric patients.

  6. A review of analytical techniques to determine long-lived radiobiologically significant nuclides in encapsulated waste

    International Nuclear Information System (INIS)

    Amey, M.H.D.; Kenward, D.; Symons, W.J.

    1985-05-01

    Methods have been identified, or are proposed for, most of the radionuclides considered important for long term storage. From the information obtained the development of liquid chromatography together with an in-line radiochemical detector is proposed as a powerful technique for sequential separation and analysis of multi-component systems. (UK)

  7. Utilization of analytical techniques in aid the implantation of nuclear installations

    International Nuclear Information System (INIS)

    Ferreira, M.P.; Sabino, C.V.S.; Avelar, M.M.

    1984-01-01

    Nuclear, physico-chemical and classic techniques developed and utilized by Centro de Desenvolvimento de Tecnicas Nucleares are presented, as back up to the implementation and operation of nuclear installations related with several parts of fuel cycle from uranium prospecting to waste treatment samples of soils, ores, alloys, plastics, paints, biological materials, air and water were analysed. (M.C.K) [pt

  8. Characterization of thin films and surfaces by ion-beam analytical techniques

    International Nuclear Information System (INIS)

    Pelicon, P.; Budnar, M.; Zorko, B.; Razpet, A.

    1999-01-01

    The optimization of Rutherford Backscattering Spectroscopy (RBS) and Elastic Recoil Detection Analysis (ERDA) at the tandetron facility of J. Stefan Inst.e is reported. The most recent applications of these techniques for the analysis of thin films and surfaces are presented. The construction of the isotope - resolved Time-Of-Flight ERDA telescope for depth profiling of light elements is reviewed.(author)

  9. Comparative analysis of toxic elements in snuff by analytical techniques of X-ray fluorescence

    International Nuclear Information System (INIS)

    Mendoza, Mario; Olivera, Paula

    2013-01-01

    Six samples of different commercial brands of cigarettes expended in the Peruvian market have been analyzed along with two IAEA certified reference material using the technique of X-ray fluorescence energy dispersive. The results obtained in the study showed the presence of toxic metals such as Cr, Mn, Fe, Cu and Zn.

  10. An uncovered XIII century icon: Particular use of organic pigments and gilding techniques highlighted by analytical methods

    Science.gov (United States)

    Daveri, Alessia; Doherty, Brenda; Moretti, Patrizia; Grazia, Chiara; Romani, Aldo; Fiorin, Enrico; Brunetti, Brunetto Giovanni; Vagnini, Manuela

    2015-01-01

    The restoration of a panel painting depicting a Madonna and Child listed as an unknown Tuscan artist of the nineteenth century, permitted the hidden original version, a XIII century Medieval icon to be uncovered. It is discovery provided the opportunity for an extensive in situ campaign of non-invasive analytical investigations by portable imaging and spectroscopic techniques (infrared, X-ray fluorescence and diffraction, UV-Vis absorption and emission), followed by aimed micro-destructive investigations (Raman and SEM-EDS). This approach permitted characterization of the original ground and paint layers by complementary techniques. Furthermore, this protocol allowed supplementary particularities of great interest to be highlighted. Namely, numerous original gilding techniques have been accentuated in diverse areas and include the use of surrogate gold (disulphur tin), orpiment as a further false gold and an area with an original silver rich layer. Moreover, pigments including azurite mixed with indigo have been non-invasively identified. Micro-invasive analyses also allowed the diagnosis of organic colorants, namely, an animal anthraquinone lake, kermes and an unusual vegetal chalcone pigment, possibly safflower. The identification of the latter is extremely rare as a painting pigment and has been identified using an innovative adaption to surface enhanced Raman techniques on a cross-section. The resulting data contributes new hypotheses to the historic and artistic knowledge of materials and techniques utilized in XIII century icon paintings and ultimately provides scientific technical support of the recent restoration.

  11. Development of sulfide calibration standards for the laser ablation inductively-coupled plasma mass spectrometry technique

    Science.gov (United States)

    Wilson, S.A.; Ridley, W.I.; Koenig, A.E.

    2002-01-01

    The requirements of standard materials for LA-ICP-MS analysis have been difficult to meet for the determination of trace elements in sulfides. We describe a method for the production of synthetic sulfides by precipitation from solution. The method is detailed by the production of approximately 200 g of a material, PS-1, with a suite of chalcophilic trace elements in an Fe-Zn-Cu-S matrix. Preliminary composition data, together with an evaluation of the homogeneity for individual elements, suggests that this type of material meets the requirements for a sulfide calibration standard that allows for quantitative analysis. Contamination of the standard with Na suggests that H2S gas may prove a better sulfur source for future experiments. We recommend that calibration data be collected in whatever mode is closest to that employed for the analysis of the unknown material, because of variable fractionation effects as a function of analytical mode. For instance, if individual spot analyses are attempted on unknown sample, then a raster of several individual spot analyses, not a continuous scan, should be collected and averaged for the standard. Hg and Au are exceptions to the above and calibration data should always be collected in a scanning mode. Au is more heterogeneously distributed than other trace metals and large-area scans are required to provide an average value for calibration purposes. We emphasize that the values given in Table 1 are preliminary values. Further chemical characterization of this standard, through a round-robin analysis program, will allow the USGS to provide both certified and recommended values for individual elements. The USGS has developed PS-1 as a potential new LA-ICP-MS standard for use by the analytical community, and requests for this material should be addressed to S. Wilson. However, it is stressed that an important aspect of the method described here is the flexibility for individual investigators to produce sulfides with a wide range

  12. Side-by-side comparison of analytical techniques; organic acids, total organic carbon, and anions in PWR secondary cycles

    International Nuclear Information System (INIS)

    Hobart, S.A.; Byers, W.A.; Miller, M.R.; Richards, J.; Silva, H.; Palino, G.F.; Wall, P.S.

    1986-01-01

    Total Organic Carbon TOC samples should be analyzed no later than one week after they are taken and they should be stored in a refrigerated condition, if at all possible. It can be inferred that for TOC levels in the range of 50 to 120 ppb, state-of-the-art sampling and analysis techniques can produce results varying by 20 to 50 ppb. Any proposed limits for TOC should be reviewed in that light. Agreement between anion results appeared to improve over the course of the project. Both contractors agree that increased attention and care with sampling and analytical techniques probably accounted for this improvement. Utility personnel can therefore conclude that proper employee training, supervision, and motivation for proper sampling and analysis are critical if accurate anion results are to be obtained. Resonable agreement between calculated and measured values of cation conductivity suggest that both contractors had accurately determined all major anionic species

  13. Analytical study of nonlinear phase shift through stimulated Brillouin scattering in single mode fiber with the pump power recycling technique

    International Nuclear Information System (INIS)

    Al-Asadi, H A; Mahdi, M A; Bakar, A A A; Adikan, F R Mahamd

    2011-01-01

    We present a theoretical study of nonlinear phase shift through stimulated Brillouin scattering in single mode optical fiber. Analytical expressions describing the nonlinear phase shift for the pump and Stokes waves in the pump power recycling technique have been derived. The dependence of the nonlinear phase shift on the optical fiber length, the reflectivity of the optical mirror and the frequency detuning coefficient have been analyzed for different input pump power values. We found that with the recycling pump technique, the nonlinear phase shift due to stimulated Brillouin scattering reduced to less than 0.1 rad for 5 km optical fiber length and 0.65 reflectivity of the optical mirror, respectively, at an input pump power equal to 30 mW

  14. Microextraction techniques at the analytical laboratory: an efficient way for determining low amounts of residual insecticides in soils

    Science.gov (United States)

    Viñas, Pilar; Navarro, Tania; Campillo, Natalia; Fenoll, Jose; Garrido, Isabel; Cava, Juana; Hernandez-Cordoba, Manuel

    2017-04-01

    Microextraction techniques allow sensitive measurements of pollutants to be carried out by means of instrumentation commonly available at the analytical laboratory. This communication reports our studies focused to the determination of pyrethroid insecticides in polluted soils. These chemicals are synthetic analogues of pyrethrum widely used for pest control in agricultural and household applications. Because of their properties, pyrethroids tend to strongly absorb to soil particles and organic matter. Although they are considered as pesticides with a low toxicity for humans, long times exposure to them may cause damage in immune system and in the neurological system. The procedure here studied is based on dispersive liquid-liquid microextraction (DLLME), and permits the determination of fifteen pyrethroid compounds (allethrin, resmethrin, tetramethrin, bifenthrin, fenpropathrin, cyhalothrin, acrinathrin, permethrin, λ-cyfluthrin, cypermethrin, flucythrinate, fenvalerate, esfenvalerate, τ-fluvalinate, and deltamethrin) in soil samples using gas chromatography with mass spectrometry (GC-MS). The analytes were first extracted from the soil samples (4 g) by treatment with 2 mL of acetonitrile, 2 mL of water and 0.5 g of NaCl. The enriched organic phase (approximately 0.8 mL) was separated by centrifugation, and this solution used as the dispersant in a DLLME process. The analytes did not need to be derivatized before their injection into the chromatographic system, due to their volatility and thermal stability. The identification of the different pyrethroids was carried out based on their retention times and mass spectra, considering the m/z values of the different fragments and their relative abundances. The detection limits were in the 0.2-23 ng g-1 range, depending on the analyte and the sample under analysis. The authors are grateful to the Comunidad Autonóma de la Región de Murcia, Spain (Fundación Séneca, 19888/GERM/15) and to the Spanish MINECO (Project

  15. Evaluation and standardisation of fast analytical techniques for destructive radwaste control

    Energy Technology Data Exchange (ETDEWEB)

    De Simone, A.; Troiani, F. [ENEA, Unita' Rifiuti Radioattivi e Disattivazione Impianti, Centro Ricerche Saluggia, Vercelli (Italy)

    2001-07-01

    The document describes the work programme carried out by the Laboratorio Nazionale per la 'Caratterizzazione dei Rifiuti Radioattivi', in the frame of the European research project Destructive Radwaste Control. The main tasks of the research work were the evaluation of fast sample pre-treatment procedures and the development of chromatographic methods coupled to fast nuclide detection by Liquid Scintillation Counting. In order to test the High Performance Ion Chromatograph (HPIC) coupled to the Liquid Scintillation Counter (LSC) on high salt content solutions, synthetic cement solutions have been prepared and spiked with several {beta}-emitters hard to be measured with non-destructive analyses, along with other radionuclides important for the determination of the radiological inventory in radwastes. As the validation tests for the new analytical methods involved the manipulation of radioactive solutions, a remote area for HPIC-LSC apparatus has been designed and performed, in order to operate in safe conditions. According to the research programme, fast analytical methods for the chemical separation and radionuclide detection of the radioactive elements of interest, have been developed and qualified. From the results of the work, some protocols of analysis have been defined: they contain all information about operative conditions for HPIC-LSC apparatus, field of applicability, chemical and radioactive detection limits. [Italian] Questo documento riporta il lavoro realizzato dal Laboratorio Nazionale per la Caratterizzazione dei Rifiuti Radioattivi, nell'ambito del progetto di ricerca Europeo sulle tecniche di misura distruttive per rifiuti radioattivi. Il lavoro era finalizzato sia alla valutazione di nuove procedure veloci per la preparazione dei campioni da analizzare sia allo sviluppo di metodi Cromatografici accoppiati alla rivelazione di radionuclidi mediante Conteggio a Scintillazione Liquida. La sperimentazione della Cromatografia Ionica ad

  16. Shaded computer graphic techniques for visualizing and interpreting analytic fluid flow models

    Science.gov (United States)

    Parke, F. I.

    1981-01-01

    Mathematical models which predict the behavior of fluid flow in different experiments are simulated using digital computers. The simulations predict values of parameters of the fluid flow (pressure, temperature and velocity vector) at many points in the fluid. Visualization of the spatial variation in the value of these parameters is important to comprehend and check the data generated, to identify the regions of interest in the flow, and for effectively communicating information about the flow to others. The state of the art imaging techniques developed in the field of three dimensional shaded computer graphics is applied to visualization of fluid flow. Use of an imaging technique known as 'SCAN' for visualizing fluid flow, is studied and the results are presented.

  17. Boron isotope determinations in waters and other geological materials: analytical techniques and inter-calibration of measurements.

    Science.gov (United States)

    Tonarini, Sonia; Pennisi, Maddalena; Gonfiantini, Roberto

    2009-06-01

    The (11)B/(10)B ratio exhibits wide variations in nature; thus, boron isotopes have found numerous applications in geochemistry, hydrology, and environmental studies. The main analytical techniques used are as follows: positive thermal ionisation mass spectrometry is the most precise (about 0.2 per thousand of the boron isotope ratio), but requires complex and laborious sample preparation; negative thermal ionisation mass spectrometry is less precise (about 0.5 per thousand), but rapid and suitable for water samples, whereas total evaporation-NTIMS allows for identification of the precise boron isotope composition of marine carbonates. It is expected that multi-collection system inductively coupled plasma mass spectrometry (MC-ICPMS) will eventually combine high precision with simple analytical procedures. Secondary ion mass spectrometry and laser ablation (LA)-MC-ICPMS allow in situ determinations on solid samples, but require the availability of calibration materials which are chemically and mineralogically similar to samples. These features of boron isotope measurement techniques were confirmed by the results of the first inter-laboratory comparison of measurements, organised by the Istituto di Geoscienze e Georisorse in Pisa. Finally, two examples of boron isotope applications in groundwater investigations are reported.

  18. Analytical technique for label-free multi-protein detection based on Western blot and surface-enhanced Raman scattering.

    Science.gov (United States)

    Han, Xiao X; Jia, Hui Y; Wang, Yan F; Lu, Zhi C; Wang, Chun X; Xu, Wei Q; Zhao, Bing; Ozaki, Yukihiro

    2008-04-15

    We have developed a new analytical procedure for label-free protein detection designated "Western SERS", consisting of protein electrophoresis, Western blot, colloidal silver staining, and surface-enhanced Raman scattering (SERS) detection. A novel method of silver staining for Western blot that uses a silver colloid, an excellent SERS-active substrate, is first proposed in the present study. During the process of silver staining, interactions between proteins and silver nanoparticles result in the emergence of SERS of proteins. In the present study, we use myoglobin (Mb) and bovine serum albumin (BSA) as model proteins. From different protein bands on a nitrocellulose (NC) membrane, we have observed surface-enhanced resonance Raman scattering (SERRS) spectra of Mb and SERS spectra of BSA. The proposed technique offers dual advantages of simplicity and high sensitivity. On one hand, after the colloidal silver staining, we can detect label-free multi-proteins directly on a NC membrane without digestion, extraction, and other pretreatments. On the other hand, the detection limit of the Western SERS is almost consistent with the detection limit of colloidal silver staining, and the SERRS detection limit of Mb is found to be 4 ng/band. This analytical method, which combines the technique of protein separation with SERS, may be a powerful protocol for label-free protein detection in proteomic research.

  19. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    Energy Technology Data Exchange (ETDEWEB)

    Parsapour, Amir, E-mail: amirparsapour@gmail.com [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Dehkordi, Behzad Mirzaeian, E-mail: mirzaeian@eng.ui.ac.ir [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Moallem, Mehdi, E-mail: moallem@cc.iut.ac.ir [Department of Electrical Engineering, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2015-03-15

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated.

  20. Medical ethical standards in dermatology: an analytical study of knowledge, attitudes and practices.

    Science.gov (United States)

    Mostafa, W Z; Abdel Hay, R M; El Lawindi, M I

    2015-01-01

    Dermatology practice has not been ethically justified at all times. The objective of the study was to find out dermatologists' knowledge about medical ethics, their attitudes towards regulatory measures and their practices, and to study the different factors influencing the knowledge, the attitude and the practices of dermatologists. This is a cross-sectional comparative study conducted among 214 dermatologists, from five Academic Universities and from participants in two conferences. A 54 items structured anonymous questionnaire was designed to describe the demographical characteristics of the study group as well as their knowledge, attitude and practices regarding the medical ethics standards in clinical and research settings. Five scoring indices were estimated regarding knowledge, attitude and practice. Inferential statistics were used to test differences between groups as indicated. The Student's t-test and analysis of variance were carried out for quantitative variables. The chi-squared test was conducted for qualitative variables. The results were considered statistically significant at a P > 0.05. Analysis of the possible factors having impact on the overall scores revealed that the highest knowledge scores were among dermatologists who practice in an academic setting plus an additional place; however, this difference was statistically non-significant (P = 0.060). Female dermatologists showed a higher attitude score compared to males (P = 0.028). The highest significant attitude score (P = 0.019) regarding clinical practice was recorded among those practicing cosmetic dermatology. The different studied groups of dermatologists revealed a significant impact on the attitude score (P = 0.049), and the evidence-practice score (P dermatology research. © 2014 European Academy of Dermatology and Venereology.

  1. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  2. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  3. Trace element air pollution monitoring studies in Slovenia using nuclear analytical techniques

    International Nuclear Information System (INIS)

    Smodis, S.B.; Jacimovic, R.; Jeran, Z.; Miklavcic, V.; Stegnar, P.; Stropnik, B.

    1994-01-01

    In the past, only a few investigations have been performed in Slovenia concerning trace elements, toxic elements, heavy metals and radionuclides in the atmosphere. During recent years, several projects were initiated, involving health-related studies connected to air pollution in highly exposed areas, mapping the status of air pollution in the whole country using biomonitors, as well as some specific research, i.e. involving studies of mercury speciation in the atmosphere around a mercury mine or concentration levels of radionuclides in biomonitors around a uranium mine. Since all these projects were or are of a preliminary nature, in this report, the emphasis is mainly on the methodology and analytical development (neutron activation analysis and X-ray spectrometry), and to a lesser extent on the results obtained up to now. Efforts are being put into co-ordination of all the presently running projects in order to complement the results and to make a unified database for their later evaluation and statistical interpretation. (author). 22 refs, 1 fig., 1 tab

  4. Markov-CA model using analytical hierarchy process and multiregression technique

    Science.gov (United States)

    Omar, N. Q.; Sanusi, S. A. M.; Hussin, W. M. W.; Samat, N.; Mohammed, K. S.

    2014-06-01

    The unprecedented increase in population and rapid rate of urbanisation has led to extensive land use changes. Cellular automata (CA) are increasingly used to simulate a variety of urban dynamics. This paper introduces a new CA based on an integration model built-in multi regression and multi-criteria evaluation to improve the representation of CA transition rule. This multi-criteria evaluation is implemented by utilising data relating to the environmental and socioeconomic factors in the study area in order to produce suitability maps (SMs) using an analytical hierarchical process, which is a well-known method. Before being integrated to generate suitability maps for the periods from 1984 to 2010 based on the different decision makings, which have become conditioned for the next step of CA generation. The suitability maps are compared in order to find the best maps based on the values of the root equation (R2). This comparison can help the stakeholders make better decisions. Thus, the resultant suitability map derives a predefined transition rule for the last step for CA model. The approach used in this study highlights a mechanism for monitoring and evaluating land-use and land-cover changes in Kirkuk city, Iraq owing changes in the structures of governments, wars, and an economic blockade over the past decades. The present study asserts the high applicability and flexibility of Markov-CA model. The results have shown that the model and its interrelated concepts are performing rather well.

  5. Determination of trace elements in drinking tea by various analytical techniques

    International Nuclear Information System (INIS)

    Wang Chufang; Ke Chenghsiung; Yang Jenqyann

    1993-01-01

    Tea has been one of the most popular simulating beverages which is both heavily produced and consumed in Taiwan. The determination of minor or trace elements in drinking tea and tea leaves is therefore important for estimating the daily intake of Taiwanese considered as a safety indicator. In order to accurately and precisely determine the concentrations of trace elements in samples, several analytical methods such as AAS, NAA and ICP-AES are suggested. This paper attempts to utilize all three methods to determine the concentrations of minor or trace elements in different types of tea leaves and the extracts percolated from them. The influence of fermentation processes on the concentration levels of minor or trace elements in tea samples is investigated. Because only free metal ions are bioavailable for the human body, it is necessary to determine their concentrations in drinking tea. The dissolution of trace elements in drinking tea is therefore studied by simulating the common Chinese style of tea percolation. Concentrations of thirteen elements including Zn, Mn, Ca, Cu, Ni, Al, K, Mg, Cd, Pb, Na, Co and Sc are determined. (author) 14 refs.; 1 fig.; 6 tabs

  6. Applications of Nuclear Analytical Techniques to Investigate the Authenticity of Art Objects

    International Nuclear Information System (INIS)

    Olivera, P.; Lopez, A.; Bedregal, P.; Santiago, J.; Petrick, S.; Bravo, J.; Alcalde, J.; Isla, J.; Vetter, L.; Baca, E.

    2011-01-01

    127 Nasca pottery and 10 imitations were analyzed by TL, NAA, XRF, TEM, DRX and Mossbauer spectroscopy to obtain analytical differences that allow differentiating them quickly. Additionally 20 pieces of the Wari culture found in the city of Cahuachi were analyzed. The multielementary composition of Nasca ceramics obtained by AAN allows, thanks to the multivariate analysis, differentiates the samples according to its geographic origin but we couldn't obtain a chronological classification. This indicates that Nasca pottery of each city was always prepared with the same raw material. However we can not classified samples from the Museum of the UNMSM, since these samples were collected in all Nazca regions. The brown, orange and yellow pigments of Nasca pottery contain different amounts of manganese and iron oxides. The same elements were found in modern ceramic, but additionally Pb and Zn were detected in the yellow color of the modern ones. The presence of illita in the paste of all the analyzed samples indicates that the firing temperature of Nasca pottery did not exceed 800 deg. C. Also, the fact that the quadrupole splitting in Mossbauer spectra as a function of temperature stays more or less constant until 700 deg. C and soon it falls quickly indicates that the firing temperature was approximately 700 deg. C. This was corroborated with the same analysis on samples from modern ceramic warmed up to approximate temperatures of 700 deg. C and 900 deg. C. (author)

  7. Short-Term Forecasting Models for Photovoltaic Plants: Analytical versus Soft-Computing Techniques

    Directory of Open Access Journals (Sweden)

    Claudio Monteiro

    2013-01-01

    Full Text Available We present and compare two short-term statistical forecasting models for hourly average electric power production forecasts of photovoltaic (PV plants: the analytical PV power forecasting model (APVF and the multiplayer perceptron PV forecasting model (MPVF. Both models use forecasts from numerical weather prediction (NWP tools at the location of the PV plant as well as the past recorded values of PV hourly electric power production. The APVF model consists of an original modeling for adjusting irradiation data of clear sky by an irradiation attenuation index, combined with a PV power production attenuation index. The MPVF model consists of an artificial neural network based model (selected among a large set of ANN optimized with genetic algorithms, GAs. The two models use forecasts from the same NWP tool as inputs. The APVF and MPVF models have been applied to a real-life case study of a grid-connected PV plant using the same data. Despite the fact that both models are quite different, they achieve very similar results, with forecast horizons covering all the daylight hours of the following day, which give a good perspective of their applicability for PV electric production sale bids to electricity markets.

  8. Analytical Modelling of the Effects of Different Gas Turbine Cooling Techniques on Engine Performance =

    Science.gov (United States)

    Uysal, Selcuk Can

    In this research, MATLAB SimulinkRTM was used to develop a cooled engine model for industrial gas turbines and aero-engines. The model consists of uncooled on-design, mean-line turbomachinery design and a cooled off-design analysis in order to evaluate the engine performance parameters by using operating conditions, polytropic efficiencies, material information and cooling system details. The cooling analysis algorithm involves a 2nd law analysis to calculate losses from the cooling technique applied. The model is used in a sensitivity analysis that evaluates the impacts of variations in metal Biot number, thermal barrier coating Biot number, film cooling effectiveness, internal cooling effectiveness and maximum allowable blade temperature on main engine performance parameters of aero and industrial gas turbine engines. The model is subsequently used to analyze the relative performance impact of employing Anti-Vortex Film Cooling holes (AVH) by means of data obtained for these holes by Detached Eddy Simulation-CFD Techniques that are valid for engine-like turbulence intensity conditions. Cooled blade configurations with AVH and other different external cooling techniques were used in a performance comparison study. (Abstract shortened by ProQuest.).

  9. Standard techniques for presentation and analysis of crater size-frequency data

    Science.gov (United States)

    1978-01-01

    In September 1977, a crater studies workshop was held for the purpose of developing standard data analysis and presentation techniques. This report contains the unanimous recommendations of the participants. This first meeting considered primarily crater size-frequency data. Future meetings will treat other aspects of crater studies such as morphologies.

  10. Yarn supplier selection using analytical hierarchy process (AHP) and standardized unitless rating (SUR) method on textile industry

    Science.gov (United States)

    Erfaisalsyah, M. H.; Mansur, A.; Khasanah, A. U.

    2017-11-01

    For a company which engaged in the textile field, specify the supplier of raw materials for production is one important part of supply chain management which can affect the company's business processes. This study aims to identify the best suppliers of raw material suppliers of yarn for PC. PKBI based on several criteria. In this study, the integration between the Analytical Hierarchy Process (AHP) and the Standardized Unitless Rating (SUR) are used to assess the performance of the suppliers. By using AHP, it can be known the value of the relative weighting of each criterion. While SUR shows the sequence performance value of the supplier. The result of supplier ranking calculation can be used to know the strengths and weaknesses of each supplier based on its performance criteria. From the final result, it can be known which suppliers should improve their performance in order to create long term cooperation with the company.

  11. Skin Absorbed Doses from Full Mouth Standard Intraoral Radiography in Bisecting Angle and Paralleling techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo; Kim, Ae Ji [Dept. of Oral Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of); Doh, Shi Hong [Dept. of Applied physics . National Fisheries University of Pusan Department of Radiotherapy, Pusan (Korea, Republic of); Kim, Hyun Ja [Dept. of Oral Radiology, Baptist Hospital, Pusan (Korea, Republic of); Yoo, Meong Jin [Dept. of Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1990-08-15

    This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography(14 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator (60 mm in diameter, 20 cm in length) and rectangular collimator (35 mm X 44 mm, 40 cm in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rats of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling technique, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20 mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  12. Skin Absorbed Doses from Full Mouth Standard Intraoral Radiography in Bisecting Angle and Paralleling techniques

    International Nuclear Information System (INIS)

    Nah, Kyung Soo; Kim, Ae Ji; Doh, Shi Hong; Kim, Hyun Ja; Yoo, Meong Jin

    1990-01-01

    This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography(14 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator (60 mm in diameter, 20 cm in length) and rectangular collimator (35 mm X 44 mm, 40 cm in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rats of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling technique, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20 mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  13. Analytical technique to address terrorist threats by chemical weapons of mass destruction

    Science.gov (United States)

    Dempsey, Patrick M.

    1997-01-01

    Terrorism is no longer an issue without effect on the American mind. We now live with the same concerns and fears that have been commonplace in other developed and third world countries for a long time. Citizens of other countries have long lived with the specter of terrorism and now the U.S. needs to be concerned and prepared for terrorist activities.T he terrorist has the ability to cause great destructive effects by focusing their effort on unaware and unprepared civilian populations. Attacks can range from simple explosives to sophisticated nuclear, chemical and biological weapons. Intentional chemical releases of hazardous chemicals or chemical warfare agents pose a great threat because of their ready availability and/or ease of production, and their ability to cause widespread damage. As this battlefront changes from defined conflicts and enemies to unnamed terrorists, we must implement the proper analytical tools to provide a fast and efficient response. Each chemical uses in a terrorists weapon leaves behind a chemical signature that can be used to identify the materials involved and possibly lead investigators to the source and to those responsible. New tools to provide fast and accurate detection for battlefield chemical and biological agent attack are emerging. Gas chromatography/mass spectrometry (GC/MS) is one of these tools that has found increasing use by the military to respond to chemical agent attacks. As the technology becomes smaller and more portable, it can be used by law enforcement personnel to identify suspected terrorist releases and to help prepare the response; define contaminated areas for evacuation and safety concerns, identify the proper treatment of exposed or affected civilians, and suggest decontamination and cleanup procedures.

  14. Elemental analyses of goundwater: demonstrated advantage of low-flow sampling and trace-metal clean techniques over standard techniques

    Science.gov (United States)

    Creasey, C. L.; Flegal, A. R.

    The combined use of both (1) low-flow purging and sampling and (2) trace-metal clean techniques provides more representative measurements of trace-element concentrations in groundwater than results derived with standard techniques. The use of low-flow purging and sampling provides relatively undisturbed groundwater samples that are more representative of in situ conditions, and the use of trace-element clean techniques limits the inadvertent introduction of contaminants during sampling, storage, and analysis. When these techniques are applied, resultant trace-element concentrations are likely to be markedly lower than results based on standard sampling techniques. In a comparison of data derived from contaminated and control groundwater wells at a site in California, USA, trace-element concentrations from this study were 2-1000 times lower than those determined by the conventional techniques used in sampling of the same wells prior to (5months) and subsequent to (1month) the collections for this study. Specifically, the cadmium and chromium concentrations derived using standard sampling techniques exceed the California Maximum Contaminant Levels (MCL), whereas in this investigation concentrations of both of those elements are substantially below their MCLs. Consequently, the combined use of low-flow and trace-metal clean techniques may preclude erroneous reports of trace-element contamination in groundwater. Résumé L'utilisation simultanée de la purge et de l'échantillonnage à faible débit et des techniques sans traces de métaux permet d'obtenir des mesures de concentrations en éléments en traces dans les eaux souterraines plus représentatives que les résultats fournis par les techniques classiques. L'utilisation de la purge et de l'échantillonnage à faible débit donne des échantillons d'eau souterraine relativement peu perturbés qui sont plus représentatifs des conditions in situ, et le recours aux techniques sans éléments en traces limite l

  15. Standardization of the Descemet membrane endothelial keratoplasty technique: Outcomes of the first 450 consecutive cases.

    Science.gov (United States)

    Satué, M; Rodríguez-Calvo-de-Mora, M; Naveiras, M; Cabrerizo, J; Dapena, I; Melles, G R J

    2015-08-01

    To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450), surgery with standardized technique. Best corrected visual acuity, endothelial cell density, pachymetry and intra- and postoperative complications were evaluated before, and 1, 3 and 6 months after DMEK. At 6 months after surgery, 79% of eyes reached a best corrected visual acuity of≥0.8 and 43%≥1.0. Mean preoperative endothelial cell density was 2,530±220 cells/mm2 and 1,613±495 at 6 months after surgery. Mean pachymetry measured 668±92 μm and 526±46 μm pre- and (6 months) postoperatively, respectively. There were no significant differences in best corrected visual acuity, endothelial cell density and pachymetry between the 3 groups (P > .05). Graft detachment presented in 17.3% of the eyes. The detachment rate declined from 24% to 12%, and the rate of secondary surgeries from 9.6% to 3.5%, from group I to III respectively. Visual outcomes and endothelial cell density after DMEK are independent of the technique standardization. However, technique standardization may have contributed to a lower graft detachment rate and a relatively low number of secondary interventions required. As such, DMEK may become the first choice of treatment in corneal endothelial disease. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  16. Judgments in the selection of path generation techniques: a meta-analytic approach

    DEFF Research Database (Denmark)

    Prato, Carlo Giacomo

    2012-01-01

    objective judgments for effective route choice set generation. Initially, path generation techniques are implemented within a synthetic network to generate possible subjective choice sets considered by travelers. Next, “true model estimates” and “postulated predicted routes” are assumed from the simulation...... of a route choice model. Then, objective choice sets are applied for model estimation and results are compared to the “true model estimates”. Last, predictions from the simulation of models estimated with objective choice sets are compared to the “postulated predicted routes”. Meta-analysis allows...

  17. Review of analytical techniques to determine the chemical forms of vapours and aerosols released from overheated fuel

    International Nuclear Information System (INIS)

    Bowsher, B.R.; Nichols, A.L.

    1989-12-01

    A comprehensive review has been undertaken of appropriate analytical techniques to monitor and measure the chemical effects that occur in large-scale tests designed to study severe reactor accidents. Various methods have been developed to determine the chemical forms of the vapours, aerosols and deposits generated during and after such integral experiments. Other specific techniques have the long-term potential to provide some of the desired data in greater detail, although considerable efforts are still required to apply these techniques to the study of radioactive debris. Such in-situ and post-test methods of analysis have been also assessed in terms of their applicability to the analysis of samples from the Phebus-FP tests. The recommended in-situ methods of analysis are gamma-ray spectroscopy, potentiometry, mass spectrometry, and Raman/UV-visible absorption spectroscopy. Vapour/aerosol and deposition samples should also be obtained at well-defined time intervals during each experiment for subsequent post-test analysis. No single technique can provide all the necessary chemical data from these samples, and the most appropriate method of analysis involves a complementary combination of autoradiography, AES, IR, MRS, SEMS/EDS, SIMS/LMIS, XPS and XRD

  18. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques

    Science.gov (United States)

    Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee

    2013-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric. PMID:28809257

  19. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques

    Directory of Open Access Journals (Sweden)

    Yeonhee Lee

    2013-05-01

    Full Text Available Time-of-flight secondary ion mass spectrometry (TOF-SIMS and X-ray photoelectron spectroscopy (XPS are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric.

  20. Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods

    Science.gov (United States)

    Wittmer, J.; Bobrowski, N.; Liotta, M.; Giuffrida, G.; Calabrese, S.; Platt, U.

    2014-07-01

    In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Concerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube technique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the field (on Stromboli Island and Mount Etna). The comparison points out that FPs are the most practical to apply but the results are error-prone compared to RT and DB, whereas the RT results in up to 13 times higher analyte concentrations than the DB in the same sampling time. An optimization of the analytical procedure, including sample pretreatment and analysis by titration, Ion Chromatography, and Inductively Coupled Plasma Mass Spectrometry, led to a comprehensive data set covering a wide range of compounds. In particular, less abundant species were quantified more accurately and iodine was detected for the first time in Stromboli's plume. Simultaneously applying Multiaxis Differential Optical Absorption Spectroscopy (MAX-DOAS) the chemical transformation of emitted bromide into bromine monoxide (BrO) from Stromboli and Etna was determined to 3-6% and 7%, respectively, within less than 5 min after the gas release from the active vents.

  1. Comparison of Analytic Hierarchy Process, Catastrophe and Entropy techniques for evaluating groundwater prospect of hard-rock aquifer systems

    Science.gov (United States)

    Jenifer, M. Annie; Jha, Madan K.

    2017-05-01

    Groundwater is a treasured underground resource, which plays a central role in sustainable water management. However, it being hidden and dynamic in nature, its sustainable development and management calls for precise quantification of this precious resource at an appropriate scale. This study demonstrates the efficacy of three GIS-based multi-criteria decision analysis (MCDA) techniques, viz., Analytic Hierarchy Process (AHP), Catastrophe and Entropy in evaluating groundwater potential through a case study in hard-rock aquifer systems. Using satellite imagery and relevant field data, eight thematic layers (rainfall, land slope, drainage density, soil, lineament density, geology, proximity to surface water bodies and elevation) of the factors having significant influence on groundwater occurrence were prepared. These thematic layers and their features were assigned suitable weights based on the conceptual frameworks of AHP, Catastrophe and Entropy techniques and then they were integrated in the GIS environment to generate an integrated raster layer depicting groundwater potential index of the study area. The three groundwater prospect maps thus yielded by these MCDA techniques were verified using a novel approach (concept of 'Dynamic Groundwater Potential'). The validation results revealed that the groundwater potential predicted by the AHP technique has a pronounced accuracy of 87% compared to the Catastrophe (46% accuracy) and Entropy techniques (51% accuracy). It is concluded that the AHP technique is the most reliable for the assessment of groundwater resources followed by the Entropy method. The developed groundwater potential maps can serve as a scientific guideline for the cost-effective siting of wells and the effective planning of groundwater development at a catchment or basin scale.

  2. An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids.

    Science.gov (United States)

    Verma, Dave K; Shaw, Don S; Shaw, M Lorraine; Julian, Jim A; McCollin, Shari-Ann; des Tombe, Karen

    2006-02-01

    This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 microg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-microm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m3 with the geometric mean ranging between 0.22 to 0.59 mg/m3. Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m3 as total mass and 0.4 mg/m3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention.

  3. New Insights into Amino Acid Preservation in the Early Oceans using Modern Analytical Techniques

    Science.gov (United States)

    Parker, E. T.; Brinton, K. L.; Burton, A. S.; Glavin, D. P.; Dworkin, J. P.; Bada, J.

    2015-12-01

    Protein- and non-protein-amino acids likely occupied the oceans at the time of the origin and evolution of life. Primordial soup-, hydrothermal vent-, and meteoritic-processes likely contributed to this early chemical inventory. Prebiotic synthesis and carbonaceous meteorite studies suggest that non-protein amino acids were likely more abundant than their protein-counterparts. Amino acid preservation before abiotic and biotic destruction is key to biomarker availability in paleoenvironments and remains an important uncertainty. To constrain primitive amino acid lifetimes, a 1992 archived seawater/beach sand mixture was spiked with D,L-alanine, D,L-valine (Val), α-aminoisobutyric acid (α-AIB), D,L-isovaline (Iva), and glycine (Gly). Analysis by high performance liquid chromatography with fluorescence detection (HPLC-FD) showed that only D-Val and non-protein amino acids were abundant after 2250 days. The mixture was re-analyzed in 2012 using HPLC-FD and a triple quadrupole mass spectrometer (QqQ-MS). The analytical results 20 years after the inception of the experiment were strikingly similar to those after 2250 days. To confirm that viable microorganisms were still present, the mixture was re-spiked with Gly in 2012. Aliquots were collected immediately after spiking, and at 5- and 9-month intervals thereafter. Final HPLC-FD/QqQ-MS analyses were performed in 2014. The 2014 analyses revealed that only α-AIB, D,L-Iva, and D-Val remained abundant. The disappearance of Gly indicated that microorganisms still lived in the mixture and were capable of consuming protein amino acids. These findings demonstrate that non-protein amino acids are minimally impacted by biological degradation and thus have very long lifetimes under these conditions. Primitive non-protein amino acids from terrestrial synthesis, or meteorite in-fall, likely experienced greater preservation than protein amino acids in paleo-oceanic environments. Such robust molecules may have reached a steady

  4. Uncertainty in soil-structure interaction analysis arising from differences in analytical techniques

    International Nuclear Information System (INIS)

    Maslenikov, O.R.; Chen, J.C.; Johnson, J.J.

    1982-07-01

    This study addresses uncertainties arising from variations in different modeling approaches to soil-structure interaction of massive structures at a nuclear power plant. To perform a comprehensive systems analysis, it is necessary to quantify, for each phase of the traditional analysis procedure, both the realistic seismic response and the uncertainties associated with them. In this study two linear soil-structure interaction techniques were used to analyze the Zion, Illinois nuclear power plant: a direct method using the FLUSH computer program and a substructure approach using the CLASSI family of computer programs. In-structure response from two earthquakes, one real and one synthetic, was compared. Structure configurations from relatively simple to complicated multi-structure cases were analyzed. The resulting variations help quantify uncertainty in structure response due to analysis procedures

  5. Analytical techniques for determination of framework oxygen isotope ratio of wairakite

    International Nuclear Information System (INIS)

    Noto, Masami; Kusakabe, Minoru; Uchida, Tetsuo.

    1990-01-01

    Dehydration techniques were developed for the analysis of isotopic ratios of framework oxygen of wairakite, one of calcium zeolites often encountered in geothermal systems. Channel water in wairakite were separated from aluminosilicate framework by dehydration in vacuum at 300 deg, 400 deg, 450 deg, 500 deg, 550 deg, 650 deg, 750 deg, 850 deg, and 950 degC, and by stepwise heating at temperatures from 300 deg to 700 degC. The oxygen isotopic analyses of the separated channel water and the residual aluminosilicate framework of wairakite indicated that dehydration at temperatures higher than 400 degC is accompanied by isotopic exchang between the framework oxygen and dehydrating water vapor. The isotopic exchange during the high temperature dehydration makes the δ 18 O of framework oxygen lower and that of channel water higher than those obtained by dehydration at 300 degC. These results are consistent with dehydration behavior of wairakite under vacuum that the maximum rate of dehydration of channel water is attained at about 400 degC. Consequently it is recommended to dehydrate wairakite at a temperature as low as possible in order to avoid the effect of the isotopic exchange. Time required to attain complete dehydration becomes longer with lowering the temperature of dehydration. To compromise these conflicting effects, the optimum conditions of dehydration have been found that most of the channel water is dehydrated at 300 degC for 24 hours, followed by stepwise heating for additional 17 hours up to 700 degC. We obtained a better than ± 0.1 reproducibility for the framework oxygen isotopic determinations with this technique. (author)

  6. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Nuclear analytical technique for the study of ancient pottery from a Ghanaian archaeological site

    International Nuclear Information System (INIS)

    Forson, A.

    2006-01-01

    Instrumental Neutron Activation Analysis (INAA) was utilized to determine the elemental concentrations of the archaeological pottery samples from Jenini slave camp in the Brong Ahafo Region, Ghana, employing the 30kW tank-in-pool Miniature Neutron Source Reactor (MNSR) at the Ghana Atomic Energy Commission (GAEC). Jenini was a slave camp of Samory Toure during the indigenous slavery and the Trans-Atlantic slave trade. The samples were obtained during the excavations of the tombs of the slaves who died at the camp. The accuracy of the INAA method was evaluated using IAEA Soil-7 reference material. The precision was calculated as relative standard deviation and was found to be within ±10%. Thirty-two (32) ceramic fragment samples from the archaeological site were analyzed to determine the concentration of 20 elements: Al, As, Ba, Ca, Ce, Co, Cr, Cs, Dy, Eu, Fe, Hf, La, Mn, Na, Sc, Sm,Th, U, and V. Two multivariate statistical methods, cluster and factor analyses, were performed on the data set in order to determine similarities and correlations between the various samples. The results of the cluster and factor analyses indicate a considerable overlap in the chemistry of the pottery shards from the three sampling points (i.e. Trench 1, Trench 2 and Pit 1) indicating that the pot shards were made from a single type of clay or clays of similar geochemical signatures. (au)

  8. Separation and preconcentration of aluminum in parenteral solutions and bottled mineral water using different analytical techniques

    International Nuclear Information System (INIS)

    Kazi, Tasneem G.; Khan, Sumaira; Baig, Jameel A.; Kolachi, Nida F.; Afridi, Hassan I.; Kandhro, Ghulam A.; Kumar, Sham; Shah, Abdul Q.

    2009-01-01

    A new method is reported for the separation of aluminum ions [Al(III)] from interfering elements in parenteral and pharmaceutical solutions (PS) and bottled mineral water (BMW) samples, through solid-phase extraction with 2-methyl-8-hydroxyquinoline (quinaldine) adsorbed onto activated silica gel. While the enrichment step of separated Al(III) was carried out by cloud point extraction (CPE) using 8-hydroxyquinoline as complexing reagent, the resulted complex was entrapped in a non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114). The enriched Al(III) in sample solutions were determined by spectrofluorometry (SPF) at λ excitation 370 nm and λ emission 510 nm, and flame atomic absorption spectrometry (FAAS) for comparative purpose. The variables affecting the complexation and extraction steps were studied and optimized. The validity of methodology was checked with certified reference material of water and standard addition method. The enrichment factor and detection limit of Al(III) for the preconcentration of 50 ml of PS and BMW were found to be 100 and 0.25 μg/L, respectively. The proposed method has been applied for the determination of trace amount of Al(III) in PS and BMW samples with satisfactory results. In PS the levels of Al(III) are above than permissible limit (25 μg/L).

  9. Assessment of levels and 'health-effects' of airborne particulate matter in mining, metal refining and metal working industries using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    2008-01-01

    The International Atomic Energy Agency (IAEA) has been supporting, over the years, several coordinated research programmes (CRPs) on various research topics related to environmental issues impacting human health. The primary aim of these CRPs has been to help enhance the research and development capabilities in the Member States, particularly among developing countries; to identify the sources of various environmental contaminants and evaluate their fate; and to provide for the basis of improved health among human populations by the use of nuclear and related analytical techniques. The CRP on Assessment of Levels and Health-Effects of Airborne Particulate Matter in Mining, Metal Refining and Metal Working Industries using nuclear and related analytical techniques focused on improving the competence for research on workplace monitoring in a variety of industrial environments. The personal monitoring of the APM (airborne particulate matter) of the exposed workforce was carried out for the first time by many participants. Nuclear and related analytical techniques, including the application of proton micro-beam, were used to generate the trace element concentration profiles in various biomarkers tissues of the exposed workers. The quality assurance/quality control (QA/QC) aspects related to the CRP were addressed through intercomparison analyses of APM on filter paper samples and freeze dried human urine samples to generate validated data. These data have helped to generate correlations between the occupational exposure measured and the magnitude of the biological response. Such new information is essential to evolve procedures to considerably reduce/eliminate the pollutants in the workplace environment and to make informed decisions on the evolution of standards in working environments aimed at preserving the health of workers. The purpose of this TECDOC is to provide an overview of the activities performed under the CRP by the participants. The overall achievements

  10. A survey on development of neutron standards and neutron measurement technique corresponding to various fields

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuro

    2007-01-01

    Various uses of neutrons are being watched in many fields such as industry, medical technology and radiation protection. Especially, high energy neutrons above 15 MeV are important in a radiation exposure issue of an aircraft and a soft error issue of a semiconductor. Therefore neutron fluence standards for the high energy region are very important. However, the standards are not almost provided all over the world. Three reasons are mainly considered: (1) poor measurement techniques for the high energy neutrons, (2) a small number of high energy neutron facilities and (3) lack of nuclear data for high energy particle reactions. In this paper, the present status of the measurement techniques, the facilities and the nuclear data is investigated and discussed. In NMIJ/AIST, the 19.0-MeV neutron fluence standard will be established by 2010, and development of high energy neutron standards above 20 MeV is also examined. An outline of the development of the high energy neutron standards is also shown in this paper. (author)

  11. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    Science.gov (United States)

    Atkins, Rahshida

    2015-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis. PMID:25626225

  12. Zinc phthalocyanine thin film and chemical analyte interaction studies by density functional theory and vibrational techniques

    International Nuclear Information System (INIS)

    Saini, G S S; Singh, Sukhwinder; Kumar, Ranjan; Tripathi, S K; Kaur, Sarvpreet; Sathe, Vasant

    2009-01-01

    Thin films of zinc phthalocyanine have been deposited on KBr and glass substrates by the thermal evaporation method and characterized by the x-ray diffraction, optical, infrared and Raman techniques. The observed x-ray diffraction and infrared absorption spectra of as-deposited thin films suggest the presence of an α crystalline phase. Infrared and Raman spectra of thin films after exposure to vapours of ammonia and methanol have also been recorded. Shifts in the position of some IR and Raman bands in the spectra of exposed films have been observed. Some bands also show changes in their intensity on exposure. Increased charge on the phthalocyanine ring and out-of-plane distortion of the core due to interaction between zinc phthalocyanine and vapour molecules involving the fifth coordination site of the central metal ion may be responsible for the band shifts. Changes in the intensity of bands are interpreted in terms of the lowering of molecular symmetry from D 4h to C 4v due to doming of the core. Molecular parameters and Mulliken atomic charges of zinc phthalocyanine and its complexes with methanol and ammonia have been calculated from density functional theory. The binding energy of the complexes have also been calculated. Calculated values of the energy for different complexes suggest that axially coordinated vapour molecules form the most stable complex. Calculated Mulliken atomic charges show net charge transfer from vapour molecules to the phthalocyanine ring for the most stable complex.

  13. Implementation of an analytical technique for Samarium; Implementacion de una tecnica analitica para Samario

    Energy Technology Data Exchange (ETDEWEB)

    Garcia G, N. [ININ, Carretera Mexico-Toluca Km. 36.5, 52045 Estado de Mexico (Mexico)

    2004-07-01

    Since the Samarium presents the same chemical properties that the plutonium, it has been used as homologous in studies that allow us to know the behavior that the plutonium presents in solution, with the advantage of working with an inactive and not very dangerous element. At the moment studies of sorption of plutonium or samarium are made on some mineral matrices that present certain surface properties. Due to the low concentrations that are used in the studies of sorption of samarium on those reagent substrates, their detection becomes very difficult for the conventional analysis media. The luminescence is a technique that can detect lower concentrations, smaller at 1 X 10{sup -} {sup 2} M, but when fluorofors are used this limit of detection increases in several orders of magnitude. In this work it has been used the arsenazo-III as fluorofor agent since it reacts in a specific way with the samarium, forming a complex that presents a proportional luminescence to the concentration of the present samarium. The advantage of making the quantification of samarium by luminescence is that it can use the same instrumental equipment to determine the speciation of the samarium sipped in the zircon. (Author)

  14. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

    Science.gov (United States)

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-04-07

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  15. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods

    International Nuclear Information System (INIS)

    Jha, Abhinav K; Frey, Eric C; Caffo, Brian

    2016-01-01

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  16. Quench correction in liquid scintillation counting by a combined internal standard-samples channels ratio technique

    International Nuclear Information System (INIS)

    Dahlberg, E.

    1982-01-01

    A well-known problem in liquid scintillation counting (LSC) is that radioactivity cannot be measured with 100% efficiency, e.g., due to ''quenching'', which thus needs be corrected for. Three methods (viz., those of internal standard (IS), samples channels ratio (SCR), and external standard channels ratio (ESCR) are in common use to accomplish quench correction. None of these methods is ideal. This paper shows that a combination of the IS and SCR methods (IS-SCR) ameliorates the major disadvantages of both techniques and the disadvantage of the SCR technique at low count rates have been eliminated in the IS-SCR method, which also has a low volume dependence compared to the IS and ESCR methods. The IS-SCR method is not affected by time-dependent diffusion of solutes and solvents into the walls of plastic counting vials, which is a major drawback of the ESCR technique. Used with a simple linear regression technique, the IS-SCR quench curves may be linearized over wide ranges of efficiencies. In view of the wide-spread application of LSC, the IS-SCR technique is therefore likely to be useful to many investigators. 2 figures, 2 tables

  17. Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

    International Nuclear Information System (INIS)

    Doody, Orla; Noe, Geertje; Given, Mark F.; Foley, Peter T.; Lyon, Stuart M.

    2009-01-01

    Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range, 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.

  18. Provenance validation of polished rice samples using nuclear and isotopic analytical techniques

    International Nuclear Information System (INIS)

    Pabroa, P.C.B.; Sucgang, R.J.; Mendoza, N.D.S.; Ebihara, M.; Peña, M.

    2015-01-01

    Rice (Oryza sativa) has been considered the best staple food among all cereals and is the staple food for over 3 billion people, constituting over half of the world’s population. Elemental and isotopic analysis revealed variance between Philippine and Japanese rice. Rice samples collected in Japan and in the Philippines (market survey samples from Metro Manila, and farm harvests from Aklan province and Central Luzon) were washed, dried and ground to fine powder. Elemental analyses of the samples were carried out using instrumental neutron activation analysis (INAA) while isotopic signatures of the samples were determined using the isotope ratio mass spectrometry (IRMS). Results show that compared with the unpolished rice standard NIES CRM10b, the polished Japanese and Philippine rice sampled show reduced concentrations of elements by as much as 1/10. 1/4 , 1/5 and 1/3 for Mg, Mn, K and Na, respectively. Levels of Ca and Zn are not greatly affected. Arsenic, probably introduced from fertilizers used in rice fields is found in all the Japanese rice tested at an average concentration of 0.103 μg/g and three out of four of the Philippine rice at an average concentration of 0.70μg/g. Higher levels of Br seen in two of the Philippine rice at 14 and 34μg/g indicated probable contamination source from the pesticide methyl bromide during quarantine. Good correlation of isotopic signatures with geographical location of polished, but not for unpolished, rice samples from Central Luzon and Aklan indicated that provenance studies are best done on polished rice samples. Isotopic with of ω’”13C show signature that of a C3 plant with possible narrow distinguishable signature with Japanese rice falling within -27.5 to -28.5 while Philippine rice within -29 to -30. Rice provenance can be ascertained using elemental analysis and isotopic abundance determination as shown by the study.(author)

  19. Painted Fiberglass-Reinforced Contemporary Sculpture: Investigating Composite Materials, Techniques and Conservation Using a Multi-Analytical Approach.

    Science.gov (United States)

    Salvadori, Barbara; Cantisani, Emma; Colombini, Maria Perla; Tognon, Cecilia Gaia Rachele

    2016-01-01

    A multi-analytical approach was used to study the constituent materials, manufacturing technique, and state of conservation of a contemporary sculpture. This sculpture, entitled Nuredduna, was created by Aligi Sassu in 1995 and is located in the "Bellariva garden" in Florence (Italy). Fourier transform infrared spectroscopy (FT-IR), optical and electronic microscopy (OM and SEM-EDS), X-ray diffraction (XRD), and portable X-ray fluorescence (XRF) highlighted the multi-layered structure of the statue: fiberglass and an overlay of different layers (gel coat) applied with an unsaturated polyester resin added with aggregate materials and bromine compounds. A top-coat in acrylic black varnish, used as a finish, was also found. The combination of these materials with their different compositions, environmental impact, and even vandalism have negatively affected the state of conservation of Nuredduna, causing the loss of strata in its lower parts (legs and feet). © The Author(s) 2015.

  20. Accelerator-based analytical technique in the evaluation of some Nigeria’s natural minerals: Fluorite, tourmaline and topaz

    Science.gov (United States)

    Olabanji, S. O.; Ige, O. A.; Mazzoli, C.; Ceccato, D.; Akintunde, J. A.; De Poli, M.; Moschini, G.

    2005-10-01

    For the first time, the complementary accelerator-based analytical technique of PIXE and electron microprobe analysis (EMPA) were employed for the characterization of some Nigeria's natural minerals namely fluorite, tourmaline and topaz. These minerals occur in different areas in Nigeria. The minerals are mainly used as gemstones and for other scientific and technological applications and therefore are very important. There is need to characterize them to know the quality of these gemstones and update the geochemical data on them geared towards useful applications. PIXE analysis was carried out using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro, Padova, Italy. The novel results which show many elements at different concentrations in these minerals are presented and discussed.

  1. Accelerator-based analytical technique in the evaluation of some Nigeria's natural minerals: Fluorite, tourmaline and topaz

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), viale dell' Universita 2, 35020 Legnaro, Padova (Italy)]. E-mail: skayode2002@yahoo.co.uk; Ige, O.A. [Natural History Museum, Obafemi Awolowo University, Ile-Ife (Nigeria); Mazzoli, C. [Dipartimento di Mineralogia e Petrologia, Universita di Padova, 35100 Padova (Italy); Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), viale dell' Universita 2, 35020 Legnaro, Padova (Italy); Dipartimento di Fisica, Universita di Padova, via Marzolo 8, 35100 Padova (Italy); Akintunde, J.A. [CERD, Obafemi Awolowo University, Ile-Ife (Nigeria); De Poli, M. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), viale dell' Universita 2, 35020 Legnaro, Padova (Italy); Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), viale dell' Universita 2, 35020 Legnaro, Padova (Italy); Dipartimento di Fisica, Universita di Padova, via Marzolo 8, 35100 Padova (Italy)

    2005-10-15

    For the first time, the complementary accelerator-based analytical technique of PIXE and electron microprobe analysis (EMPA) were employed for the characterization of some Nigeria's natural minerals namely fluorite, tourmaline and topaz. These minerals occur in different areas in Nigeria. The minerals are mainly used as gemstones and for other scientific and technological applications and therefore are very important. There is need to characterize them to know the quality of these gemstones and update the geochemical data on them geared towards useful applications. PIXE analysis was carried out using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro, Padova, Italy. The novel results which show many elements at different concentrations in these minerals are presented and discussed.

  2. Accelerator-based analytical technique in the evaluation of some Nigeria's natural minerals: Fluorite, tourmaline and topaz

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Ige, O.A.; Mazzoli, C.; Ceccato, D.; Akintunde, J.A.; De Poli, M.; Moschini, G.

    2005-01-01

    For the first time, the complementary accelerator-based analytical technique of PIXE and electron microprobe analysis (EMPA) were employed for the characterization of some Nigeria's natural minerals namely fluorite, tourmaline and topaz. These minerals occur in different areas in Nigeria. The minerals are mainly used as gemstones and for other scientific and technological applications and therefore are very important. There is need to characterize them to know the quality of these gemstones and update the geochemical data on them geared towards useful applications. PIXE analysis was carried out using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro, Padova, Italy. The novel results which show many elements at different concentrations in these minerals are presented and discussed

  3. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    Science.gov (United States)

    Parsapour, Amir; Dehkordi, Behzad Mirzaeian; Moallem, Mehdi

    2015-03-01

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared.

  4. Analytical techniques for boron and boron 10 analysis in a solid experimental tumor EO.771

    International Nuclear Information System (INIS)

    Porschen, W.; Marx, J.; Feinendegen, L.E.

    1987-01-01

    If a tumor can be preferentially loaded with a suitable boron-10 compound and irradiated with thermal neutrons, malignant cells can be selectively destroyed via the α-particle + Li 7-nucleus from the reaction 10 B(n,α) 7 Li. Neutron capture therapy with two boron-10 amino acid analogs of low toxicity has been tested in recent years: (a) trimethylamine carboxyborane, (A3) and (b) amine-carboxyborane, (A7). Now the boron-10 glycineamide analog (A8), amineboryl carboxamide has been synthsized; it contains 13.81% boron (90% Boron 10+10% Boron 11) and shows a very low toxicity in mice. The effects of this compund were tested on the syngeneic solid adenocarcinoma EO 771 on the right hind leg of male C57 BL/6J mice under standard conditions, by measuring tumor volume growth delay and cell cycle changes using flow cytometry. Boron distribution between tumor and muscle was analyzed by emission spectroscopy with inductively coupled plasma (ICP) following injection of a suspension of peanut oil emulsion. In addition, boron-10 concentration in the tumor were analyzed with prompt γ-activation analysis and neutron capture radiography (Kodak-Pathe LR115) at the MRR reactor in Brookhaven after i.p. injection of 0.4 mg/g A8. Application of A8 alone (0.4 mg/g i.p.) or thermal neutron irradiation of the tumor EO. 771 produced a tumor growth delay of 1-2 days for tumor volume doubling. Application of the boron 10 glycine-amide analog A8 i.p. plus 5x10 12 n/cm 2 resulted in a growth delay of 3-6 days. In contrast intratumoral application of A8 plus 4x10 12 n/cm 2 neutrons gave a growth delay of 7-14 days; the fraction of (G2+M) cells rose from 35% (neutrons alone) to 52%, as evaluated from flow cytometry. (orig.)

  5. Study of Brazilian archaeological ceramics by non-destructive analytical technique

    Energy Technology Data Exchange (ETDEWEB)

    Ikeoka, R.A.; Appoloni, C.R.; Parreira, P.S.; Lopes, F. [Universidade Estadual de Londrina (DF/UEL), PR (Brazil). Dept. de Fisica; Bandeira, A.M. [Universidade de Sao Paulo (MAE/USP), SP (Brazil). Museu de Arqueologia e Etnologia

    2010-07-01

    Full text: This work manages with archaeometric analysis of 68 ceramic fragments from an archaeological site in Sao Luis, Maranhao, Brazil by Portable System of Energy Dispersive X-Ray Fluorescence. Sambaqui do Bacanga archaeological site was occupied from 6600 BP until 900 BP. The Portable System (PXRF-LFNA-02) consists of an X-ray tube (Ag target and filter) to excite the samples, a Si-PIN detector (221 eV FWHM at 5.9 keV), a specially designed holder for the excitation-detection system and samples positioning, standard X-ray spectrometry electronics and a notebook for data acquisition. The aims of the work were: verify if there was some kind of treatment in the concave and convex sides in relation to the ceramic paste of the fragments; use the grouping analysis to verify the chemical similarity among the fragments of different levels and perform the quantitative analysis of the chemical elements. The elements, Fe, Sr, Mn, Ti and Zn present, systematically, higher intensities on concave and convex sides, compared to ceramic paste in 43 of 68 analyzed fragments. It indicates an existence of a differentiable surface treatment related to the paste that results in an enrichment of those elements. five sample sets with different stratigraphies were used for grouping analysis, which were dated by Thermoluminescence. Depth and dates of the stratigraphic levels are: surface, 10 to 20 cm (1,080 BP), 113 cm (2,100 BP), 132 cm (3,500 BP) and 144 cm (5,800 BP). The two-dimensional graphs of the X-ray intensities of Ca versus Zn and Sr versus Zr were performed for fragments from the surface and 113 cm; 10 to 20 cm, 132 cm and 144 cm levels, respectively. It was possible to observe the formation of five distinct groups for the fragments from the five stratigraphic levels. The results of data grouping (bi-dimensional graphics) are in agreement with cluster analysis of the Ward Method. Two cluster analysis were performed with the ceramic fragments from surface and 113 cm; 10 to

  6. Advanced Packaging Materials and Techniques for High Power TR Module: Standard Flight vs. Advanced Packaging

    Science.gov (United States)

    Hoffman, James Patrick; Del Castillo, Linda; Miller, Jennifer; Jenabi, Masud; Hunter, Donald; Birur, Gajanana

    2011-01-01

    The higher output power densities required of modern radar architectures, such as the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI) require increasingly dense high power electronics. To enable these higher power densities, while maintaining or even improving hardware reliability, requires advances in integrating advanced thermal packaging technologies into radar transmit/receive (TR) modules. New materials and techniques have been studied and compared to standard technologies.

  7. Extending and simplifying the standard Köhn-pipette technique for grain size analysis

    Science.gov (United States)

    Hirsch, Florian; Raab, Thomas

    2014-05-01

    Grain size distribution is a fundamental parameter to characterize physical properties of soils and sediments. Manifold approaches exist and according to the DIN ISO 11277 soil texture is analyzed by default with the combined pipette sieving and sedimentation method developed by Köhn. With this standard technique subfractions of sand and silt as well as the total clay content can be determined but the differentiation of clay subfractions is impossible. As the differentiation of the clay subfractions yields relevant information about pedogenesis, we present a protocol basing on standard techniques of granulometry with easy to handle and low cost equipment. The protocol was tested on a set of soil samples to cover the range of grain size distributions. We used a three-step procedure for achieving the grain size distribution of soil samples taking into account the subfractions of sand, silt and clay by a combination of sedimentation, centrifugal sedimentation and wet sieving. The pipetting was done with a piston-stroke pipette instead of the referred complex pipette from the DIN ISO 11277. Our first results show that the applied protocol is less prone to operating errors than the standard Köhn-pipette technique. Furthermore, even a less experienced laboratory worker can handle 10 samples in one day. Analyses of a luvisol profile, sampled in high spatial resolution, showed that the lessivation process is characterized by translocation of fine clay from the eluvial horizon to the illuvial horizon. Therefore our protocol is a fast alternative to detect lessivation, which is otherwise only clearly identifiable by micromorphological investigation and not by the standard Köhn-pipette technique.

  8. Impact of Standardized Communication Techniques on Errors during Simulated Neonatal Resuscitation.

    Science.gov (United States)

    Yamada, Nicole K; Fuerch, Janene H; Halamek, Louis P

    2016-03-01

    Current patterns of communication in high-risk clinical situations, such as resuscitation, are imprecise and prone to error. We hypothesized that the use of standardized communication techniques would decrease the errors committed by resuscitation teams during neonatal resuscitation. In a prospective, single-blinded, matched pairs design with block randomization, 13 subjects performed as a lead resuscitator in two simulated complex neonatal resuscitations. Two nurses assisted each subject during the simulated resuscitation scenarios. In one scenario, the nurses used nonstandard communication; in the other, they used standardized communication techniques. The performance of the subjects was scored to determine errors committed (defined relative to the Neonatal Resuscitation Program algorithm), time to initiation of positive pressure ventilation (PPV), and time to initiation of chest compressions (CC). In scenarios in which subjects were exposed to standardized communication techniques, there was a trend toward decreased error rate, time to initiation of PPV, and time to initiation of CC. While not statistically significant, there was a 1.7-second improvement in time to initiation of PPV and a 7.9-second improvement in time to initiation of CC. Should these improvements in human performance be replicated in the care of real newborn infants, they could improve patient outcomes and enhance patient safety. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. IMPROVING THE STUDENTS‘ READING COMPREHENSION THROUGH KNOW-WANT-LEARN (KWL TECHNIQUE TO TEACH ANALYTICAL EXPOSITION ( Class Action Research

    Directory of Open Access Journals (Sweden)

    Meike Imelda Wachyu

    2017-12-01

    Full Text Available This study is aimed at finding out the impacts of the use of Know-Want-Learn technique in improving the reading comprehension to teach analytical exposition among eleventh grade students of SMA N 2 Indramayu in the academic year of 2017/2018. The study was action research in two research cycles. In the study, the researcher collaborated with the English teachers and the students. The data of this study were qualitative in nature supported by quantitative data. Qualitative data were obtained from the results of classroom observation and collaborators‘ discussion. Quantitative data were obtained from pre-test and post test results. The instruments for collecting the data were observation guides, interview guides, and the pre-test and posttest. The data were in the form of field notes, interview transcripts, and the scores of the students‘ pre-test and posttest. The results of the two cycles show that the use of Know-WantLearn technique is effective to improve the students‘ reading comprehension. It is supported by the qualitative data which show that (1 Know-Want-Learn technique can help the teacher to scaffold the students‘ comprehension of the text by focusing on the steps before, during, and after reading; (2 Know-Want-Learn technique can help the students to preview the text, assess what they have learned after reading, and motivate their interest in reading; (3 The kind of activities given such as preeteaching vocabulary, using skimming and scanning, using fix-up strategies, and guessing meaning can help the students to read the text efficiently.

  10. Model-Based Data Integration and Process Standardization Techniques for Fault Management: A Feasibility Study

    Science.gov (United States)

    Haste, Deepak; Ghoshal, Sudipto; Johnson, Stephen B.; Moore, Craig

    2018-01-01

    This paper describes the theory and considerations in the application of model-based techniques to assimilate information from disjoint knowledge sources for performing NASA's Fault Management (FM)-related activities using the TEAMS® toolset. FM consists of the operational mitigation of existing and impending spacecraft failures. NASA's FM directives have both design-phase and operational-phase goals. This paper highlights recent studies by QSI and DST of the capabilities required in the TEAMS® toolset for conducting FM activities with the aim of reducing operating costs, increasing autonomy, and conforming to time schedules. These studies use and extend the analytic capabilities of QSI's TEAMS® toolset to conduct a range of FM activities within a centralized platform.

  11. Analytical Evaluation of Preliminary Drop Tests Performed to Develop a Robust Design for the Standardized DOE Spent Nuclear Fuel Canister

    International Nuclear Information System (INIS)

    Ware, A.G.; Morton, D.K.; Smith, N.L.; Snow, S.D.; Rahl, T.E.

    1999-01-01

    The Department of Energy (DOE) has developed a design concept for a set of standard canisters for the handling, interim storage, transportation, and disposal in the national repository, of DOE spent nuclear fuel (SNF). The standardized DOE SNF canister has to be capable of handling virtually all of the DOE SNF in a variety of potential storage and transportation systems. It must also be acceptable to the repository, based on current and anticipated future requirements. This expected usage mandates a robust design. The canister design has four unique geometries, with lengths of approximately 10 feet or 15 feet, and an outside nominal diameter of 18 inches or 24 inches. The canister has been developed to withstand a drop from 30 feet onto a rigid (flat) surface, sustaining only minor damage - but no rupture - to the pressure (containment) boundary. The majority of the end drop-induced damage is confined to the skirt and lifting/stiffening ring components, which can be removed if de sired after an accidental drop. A canister, with its skirt and stiffening ring removed after an accidental drop, can continue to be used in service with appropriate operational steps being taken. Features of the design concept have been proven through drop testing and finite element analyses of smaller test specimens. Finite element analyses also validated the canister design for drops onto a rigid (flat) surface for a variety of canister orientations at impact, from vertical to 45 degrees off vertical. Actual 30-foot drop testing has also been performed to verify the final design, though limited to just two full-scale test canister drops. In each case, the analytical models accurately predicted the canister response

  12. Analytic parallel-polarized light imaging technique using various light-emitting diodes: a comparison with skin conductance values.

    Science.gov (United States)

    Kim, D H; Choi, J E; Ryu, H J; Seo, S H; Kye, Y C; Ahn, H H

    2015-05-01

    The quantitative difference of the light reflected from a skin surface can be analyzed using parallel-polarized light (PPL) photography when combined with an analytic technique similar to colorimetric photography. To improve the PPL photography technique as an assessment tool for the evaluation of skin condition using light-emitting diodes (LED) of different colors. Parallel-polarized light images were taken using white and green LED illuminators. The acquired images were transformed to CIELAB coordinates. An in-house skin conductance meter was constructed to assess skin hydration level. A dermatologist evaluated the clinical grading of dryness and glossiness. These clinical severities were also compared statistically with the CIELAB values. As with the green illuminator, the correlation analysis of whole sites showed that the L* value positively correlated with age (r = 0.18677, P < 0.05), and that the a* value has negative and positive relationships with age (r = -0.20528, P < 0.05) and glossiness (r = 0.20885, P < 0.05) respectively. The correlations between CIELAB values and multiple characteristics of skin were more significant when green LED was applied than when white light was applied. In addition, coherent relationships between the grade of dryness and skin conductance values showed that visual assessment could be appropriate for the study as with objective measurement. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Progressing towards more quantitative analytical pyrolysis of soil organic matter using molecular beam mass spectroscopy of whole soils and added standards

    Energy Technology Data Exchange (ETDEWEB)

    Haddix, Michelle L.; Magrini-Bair, Kim; Evans, Robert J.; Conant, Richard T.; Wallenstein, Matthew D.; Morris, Sherri J.; Calderón, Francisco; Paul, Eldor A.

    2016-12-01

    Soil organic matter (SOM) is extremely complex. It is composed of hundreds of different organic substances and it has been difficult to quantify these diverse substances in a dynamic-ecosystem functioning standpoint. Analytical pyrolysis has been used to compare chemical differences between soils, but its ability to measure the absolute amount of a specific compound in the soil is still in question. Our objective was to assess whether utilizing pyrolysis-molecular beam mass spectroscopy (py-MBMS) to define the signature of known reference compounds (adenine, indole, palmitic acid, etc.) and biological samples (chitin, fungi, cellulose, etc.) separately and when added to whole soils it was possible to make py-MBMS more quantitative. Reference compounds, spanning a wide variety of compound categories, and biological samples, expected to be present in SOM, were added to three soils from Colorado, Ohio, and Massachusetts that have varying total C, % clay, and clay type. Py-MBMS, a rapid analysis technique originally developed to analyze complex biomolecules, flash pyrolyzes soil organic matter to form products that are often considered characteristic of the original molecular structure. Samples were pyrolyzed at 550 degrees C by py-MBMS. All samples were weighed and %C and %N determined both before and after pyrolysis to evaluate mass loss, C loss, and N loss for the samples.An average relationship of r2 = 0.76 (P = 0.005) was found for the amount of cellulose added to soil at 25, 50, and 100% of soil C relative to the ion intensity of select mass/charge of the compound.There was a relationship of r2 = 0.93 (P < 0.001) for the amount of indole added to soil at 25, 50, and 100% of soil C and the ion intensity of the associated mass variables (mass/charge). Comparing spectra of pure compounds with the spectra of the compounds added to soil and isolated clay showed that interference could occur based on soil type and compound with the Massachusetts soil with high C (55

  14. [Studies on the identification of psychotropic substances. VIII. Preparation and various analytical data of reference standard of some stimulants, amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex].

    Science.gov (United States)

    Shimamine, M; Takahashi, K; Nakahara, Y

    1992-01-01

    The Reference Standards for amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex were prepared. Their purities determined by HPLC were more than 99.5%. For the identification and determination of these six drugs, their analytical data were measured and discussed by TLC, UV, IR, HPLC, GC/MS and NMR.

  15. Standard practice for monitoring atmospheric SO2 using the sulfation plate technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This practice covers a weighted average effective SO2 level for a 30-day interval through the use of the sulfation plate method, a technique for estimating the effective SO2 content of the atmosphere, and especially with regard to the atmospheric corrosion of stationary structures or panels. This practice is aimed at determining SO2 levels rather than sulfuric acid aerosol or acid precipitation. 1.2 The results of this practice correlate approximately with volumetric SO2 concentrations, although the presence of dew or condensed moisture tends to enhance the capture of SO2 into the plate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Comparisons of neural networks to standard techniques for image classification and correlation

    Science.gov (United States)

    Paola, Justin D.; Schowengerdt, Robert A.

    1994-01-01

    Neural network techniques for multispectral image classification and spatial pattern detection are compared to the standard techniques of maximum-likelihood classification and spatial correlation. The neural network produced a more accurate classification than maximum-likelihood of a Landsat scene of Tucson, Arizona. Some of the errors in the maximum-likelihood classification are illustrated using decision region and class probability density plots. As expected, the main drawback to the neural network method is the long time required for the training stage. The network was trained using several different hidden layer sizes to optimize both the classification accuracy and training speed, and it was found that one node per class was optimal. The performance improved when 3x3 local windows of image data were entered into the net. This modification introduces texture into the classification without explicit calculation of a texture measure. Larger windows were successfully used for the detection of spatial features in Landsat and Magellan synthetic aperture radar imagery.

  17. Analytical validation of a standardized scoring protocol for Ki67: phase 3 of an international multicenter collaboration

    Science.gov (United States)

    Leung, Samuel C Y; Nielsen, Torsten O; Zabaglo, Lila; Arun, Indu; Badve, Sunil S; Bane, Anita L; Bartlett, John M S; Borgquist, Signe; Chang, Martin C; Dodson, Andrew; Enos, Rebecca A; Fineberg, Susan; Focke, Cornelia M; Gao, Dongxia; Gown, Allen M; Grabau, Dorthe; Gutierrez, Carolina; Hugh, Judith C; Kos, Zuzana; Lænkholm, Anne-Vibeke; Lin, Ming-Gang; Mastropasqua, Mauro G; Moriya, Takuya; Nofech-Mozes, Sharon; Osborne, C Kent; Penault-Llorca, Frédérique M; Piper, Tammy; Sakatani, Takashi; Salgado, Roberto; Starczynski, Jane; Viale, Giuseppe; Hayes, Daniel F; McShane, Lisa M; Dowsett, Mitch

    2016-01-01

    Pathological analysis of the nuclear proliferation biomarker Ki67 has multiple potential roles in breast and other cancers. However, clinical utility of the immunohistochemical (IHC) assay for Ki67 immunohistochemistry has been hampered by unacceptable between-laboratory analytical variability. The International Ki67 Working Group has conducted a series of studies aiming to decrease this variability and improve the evaluation of Ki67. This study tries to assess whether acceptable performance can be achieved on prestained core-cut biopsies using a standardized scoring method. Sections from 30 primary ER+ breast cancer core biopsies were centrally stained for Ki67 and circulated among 22 laboratories in 11 countries. Each laboratory scored Ki67 using three methods: (1) global (4 fields of 100 cells each); (2) weighted global (same as global but weighted by estimated percentages of total area); and (3) hot-spot (single field of 500 cells). The intraclass correlation coefficient (ICC), a measure of interlaboratory agreement, for the unweighted global method (0.87; 95% credible interval (CI): 0.81–0.93) met the prespecified success criterion for scoring reproducibility, whereas that for the weighted global (0.87; 95% CI: 0.7999–0.93) and hot-spot methods (0.84; 95% CI: 0.77–0.92) marginally failed to do so. The unweighted global assessment of Ki67 IHC analysis on core biopsies met the prespecified criterion of success for scoring reproducibility. A few cases still showed large scoring discrepancies. Establishment of external quality assessment schemes is likely to improve the agreement between laboratories further. Additional evaluations are needed to assess staining variability and clinical validity in appropriate cohorts of samples. PMID:28721378

  18. Rapid Late Holocene glacier fluctuations reconstructed from South Georgia lake sediments using novel analytical and numerical techniques

    Science.gov (United States)

    van der Bilt, Willem; Bakke, Jostein; Werner, Johannes; Paasche, Øyvind; Rosqvist, Gunhild

    2016-04-01

    The collapse of ice shelves, rapidly retreating glaciers and a dramatic recent temperature increase show that Southern Ocean climate is rapidly shifting. Also, instrumental and modelling data demonstrate transient interactions between oceanic and atmospheric forcings as well as climatic teleconnections with lower-latitude regions. Yet beyond the instrumental period, a lack of proxy climate timeseries impedes our understanding of Southern Ocean climate. Also, available records often lack the resolution and chronological control required to resolve rapid climate shifts like those observed at present. Alpine glaciers are found on most Southern Ocean islands and quickly respond to shifts in climate through changes in mass balance. Attendant changes in glacier size drive variations in the production of rock flour, the suspended product of glacial erosion. This climate response may be captured by downstream distal glacier-fed lakes, continuously recording glacier history. Sediment records from such lakes are considered prime sources for paleoclimate reconstructions. Here, we present the first reconstruction of Late Holocene glacier variability from the island of South Georgia. Using a toolbox of advanced physical, geochemical (XRF) and magnetic proxies, in combination with state-of-the-art numerical techniques, we fingerprinted a glacier signal from glacier-fed lake sediments. This lacustrine sediment signal was subsequently calibrated against mapped glacier extent with the help of geomorphological moraine evidence and remote sensing techniques. The outlined approach enabled us to robustly resolve variations of a complex glacier at sub-centennial timescales, while constraining the sedimentological imprint of other geomorphic catchment processes. From a paleoclimate perspective, our reconstruction reveals a dynamic Late Holocene climate, modulated by long-term shifts in regional circulation patterns. We also find evidence for rapid medieval glacier retreat as well as a

  19. Application of quality function deployment (QFD and analytic hierarchy process (AHP techniques to improve the quality of postgraduate training

    Directory of Open Access Journals (Sweden)

    Antonio Pastor Sanmillán

    2016-05-01

    Full Text Available The importance of ensuring quality in higher education is evident in the number of local, national and transnational organizations dedicated to this end. The impressive volume of works published on quality in education is further testimony to its importance. All university, traditional or on-line, has a department dedicated to the study of quality, and the academic literature in this area is extremely broad in scope. Yet in this abundant wealth of studies, methodologies, techniques, fantasies and realities in which professors and university administrators, teachers, psychologists, marketing experts and quality professionals focus their attention, there is in our opinion something basic and elemental which is frequently forgotten: to ask the student, the end user (who should be the fundamental object of our interest what aspects of postgraduate study he truly values. The goal of the present study will be to verify the usefulness of multi-criteria analysis, and of the analytic hierarchy process (AHP in particular, attached to quality function deployment (QFD, for performing this task in multicultural environments. The population chosen for our study is comprised of the students enrolled in on-site postgraduate programs at the CEF School of Business.

  20. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, M.; Lalor, G.C.; Preston, J.

    1999-01-01

    Air quality has been monitored at selected areas in Jamaica using high volume samplers. The results obtained, showed elevated levels of aluminium in bauxitic areas and very high lead concentrations in urban areas, from 5 to 35 times greater than in rural areas. The lower throughput of the conventional air particulate samplers however, restricts the air quality and health assessment on a nation-wide scale. Biomonitoring offers a cost-effective alternative to air-quality assessment if appropriate indicator species are chosen. The epiphytic lower plants such as lichens and mosses have been used as indicators of regional air quality in several European countries and USA. However, there is not enough studies on lichens and mosses in tropical countries, probably due to the lower occurrence of these species, which cover only 8% of the world's land surface. In Jamaica the epiphytic higher plants, represented by the genus Tillandsia are widely distributed, which make them along with the lichens and mosses potential site-specific bioindicators of air quality. The IAEA Co-ordinated Research Project entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear And Related Analytical Techniques' will address these needs of the country. The primary purpose of the present study was to develop specific bioindicators of atmospheric air pollution in Jamaica, which will provide baseline information for health hazards assessment

  1. The use of nuclear related analytical techniques for the determination of ingestion and body content of trace elements

    International Nuclear Information System (INIS)

    Djojosubroto, H.; Santoso, D.; Widjajakusuma, B.

    1998-01-01

    A number of observations revealed that various human disease states are associated with measurable abnormalities of trace element levels. Until present there is no data on trace element levels in human tissues and dietary intake representing the population in Indonesia. Trace element level in various biological materials, especially human serum related to health syndrome (e.g. acute myocardial infarction and goiter prevalences) was performed by National Atomic Energy Agency in cooperation with relevant institutes. The present study is concerned with determination of ingestion and organ content of trace elements of importance in radiological protection (Cs, Sr, I, Th and U). Quantitation of the elements in the samples will be determined by neutron activation analysis, complemented by nuclear related analytical techniques, e.g. inductively coupled plasma - mass spectrometry and atomic absorption spectrometry. Samples to be analyzed consist of (a) total diets and individual staple foodstuffs, (b) autopsy specimens of liver, lung, kidney, muscle, thyroid and bone, and (c) drinking water. It seems difficult for us to define nationally representative specimens of total diets and individual staple foodstuffs. Based on these facts, in the first year activity samples of dietary intake from various socio economic levels of population in West Java will be collected. Human tissue sample is obtained from autopsy of normal persons who are killed in traffic accident or homicide victim. Traces of Th and U in drinking water are determined by neutron activation analysis following preconcentration of these elements in chelating resin Chlelex 100. (author)

  2. Characterization of pre-hispanic pigments by modern analytical techniques; Caracterizacion de pigmentos prehispanicos por tecnicas analiticas modernas

    Energy Technology Data Exchange (ETDEWEB)

    Ortega A, M

    2003-07-01

    In this work, the study of mural painting pigments from two archaeological sites (The Great Temple in Mexico city and Cacaxtla) was performed to know their materials composition, identify their structural characteristics and properties by using modern analytical techniques. Blue, ochre, red and black pigments of Mexica culture (1325-1521 a.C. / late Post Classic period); blue, ochre, red, brown, pink, green and white of Olmeca- Xicalanca culture (700-900 a.C. / Epiclassic period) were studied. Data about materials used, technological evolution, mineralogical background, cultural interchange and origin was obtained. Environmental exposition of these paintings since their discovering has produced changes and damage on their materials. Therefore, stability of some pigments has been notorious, ''Maya Blue'' specially presents extraordinary resistance to diluted and concentrated acids and alkalis including boiling condition, acqua regia, solvents, oxidant and reducing agents, moderate heat and biocorrosi6n; for that reason its study was emphasized. ''Maya Blue'' pigment was synthesized in laboratory using the processes described by historic sources (with indigophera suffruticosa leaves and synthetic indigo) up to obtain a stable pigment including acqua regia action. Clay matrix sorbs nearly 0.4 weight percent of organic dye, which cover 79% of palygorskita surface area. (Author)

  3. Quality control and quality assurance of nuclear analytical techniques. Thematic planning of QC/QA in technical co-operations. Report of the external participants

    International Nuclear Information System (INIS)

    Innes, R.W.; Bode, P.; Brickenkamp, C.S.; Casa, A.; Abdul Khalik Haji Wood

    1998-02-01

    In areas of trade, health, safety, and environmental protection users of a laboratory's analytical results, for example by governments and private institutions, are increasingly requiring demonstrable proof of the reliability and credibility of the laboratory's analytical results using internationally accepted standards. This is so that the products and the decisions based on these laboratory results will be accepted in the respective national and international communities. These requirements are being imposed, for example by the European Community and others, for products to be imported and can be a significant barrier to trade, especially for developing nations. In addition to this there is a growing need for these laboratories to operate efficiently and effectively to reduce internal waste, to provide reports on time in an economical manner and to become self supporting. The need for change is global and this proposal is for the Agency to pursue a thematic plan for the implementation of quality assurance as partners in development with the selected laboratories using nuclear analytical techniques. This report describes a model project for this thematic approach to confirm the models immediate benefits as well as facilitating long-term sustainability of member states' laboratories. The model is thematic in that it is also applicable to all other projects for which the credibility and reliability of the results of a laboratory's processes and results must be demonstrated. This model project provides a cost effective approach for protecting the Agency's investment in these laboratories and strengthening the ability of these national institutions to define, organize, and manage the application of nuclear technology in their respective countries. This pilot project consists of (1) determining the general levels of knowledge and application of quality assurance principles (as delineated in ISO Guide 25) in the responding laboratories; (2) selecting a trail group of

  4. Outcome of a standardized technique of preputial preservation surgery for phimosis: A single institutional experience

    Directory of Open Access Journals (Sweden)

    Kamalesh Pal

    2014-01-01

    Full Text Available Introduction: Pathological phimosis or preputial stenosis is a distressing problem in children leading to recurrent balanoposthitis, ballooning of prepuce, and rarely back pressure changes in the urinary tract. Circumcision has been the standard of care for such situations, although recently, various alternatives to circumcision have been reported in the literature. Most of these techniques are often complex and are met with poor acceptance. Moreover, besides personal preferences (in Hindus, advantages of preputial preservation is increasingly being realized recently. Materials and Methods: A prospective study was carried out in which a simple standardized technique of preputioplasty (dorsal slit was used in 40 pediatric preputial stenosis cases. The outcome of this procedure including cosmesis and parental satisfaction was evaluated. Results: The average duration of this procedure was from 10 to 25 min with no intraoperative complications. The cosmetic outcome was good in 62.5%, satisfactory in 30%, and poor in 7.5% of cases. All of the boys had retractable prepuce with no functional problems. There was 100% parental satisfaction. None of the patients required a redo procedure or circumcision. Conclusion: A dorsal slit of adequate length i.e.; 1/3 rd the length from the corona to the tip leads to a satisfactory cosmetic outcome in more than 92% of cases. Preputioplasty is a safe and simple alternative to more radical procedure of circumcision.

  5. Closing the gap: accelerating the translational process in nanomedicine by proposing standardized characterization techniques

    Science.gov (United States)

    Khorasani, Ali A; Weaver, James L; Salvador-Morales, Carolina

    2014-01-01

    On the cusp of widespread permeation of nanomedicine, academia, industry, and government have invested substantial financial resources in developing new ways to better treat diseases. Materials have unique physical and chemical properties at the nanoscale compared with their bulk or small-molecule analogs. These unique properties have been greatly advantageous in providing innovative solutions for medical treatments at the bench level. However, nanomedicine research has not yet fully permeated the clinical setting because of several limitations. Among these limitations are the lack of universal standards for characterizing nanomaterials and the limited knowledge that we possess regarding the interactions between nanomaterials and biological entities such as proteins. In this review, we report on recent developments in the characterization of nanomaterials as well as the newest information about the interactions between nanomaterials and proteins in the human body. We propose a standard set of techniques for universal characterization of nanomaterials. We also address relevant regulatory issues involved in the translational process for the development of drug molecules and drug delivery systems. Adherence and refinement of a universal standard in nanomaterial characterization as well as the acquisition of a deeper understanding of nanomaterials and proteins will likely accelerate the use of nanomedicine in common practice to a great extent. PMID:25525356

  6. Study of the standard direct costs of various techniques of advanced endoscopy. Comparison with surgical alternatives.

    Science.gov (United States)

    Loras, Carme; Mayor, Vicenç; Fernández-Bañares, Fernando; Esteve, Maria

    2018-03-12

    The complexity of endoscopy has carried out an increase in cost that has a direct effect on the healthcare systems. However, few studies have analyzed the cost of advanced endoscopic procedures (AEP). To carry out a calculation of the standard direct costs of AEP, and to make a financial comparison with their surgical alternatives. Calculation of the standard direct cost in carrying out each procedure. An endoscopist detailed the time, personnel, materials, consumables, recovery room time, stents, pathology and medication used. The cost of surgical procedures was the average cost recorded in the hospital. Thirty-eight AEP were analyzed. The technique showing lowest cost was gastroscopy + APC (€116.57), while that with greatest cost was ERCP with cholangioscopy + stent placement (€5083.65). Some 34.2% of the procedures registered average costs of €1000-2000. In 57% of cases, the endoscopic alternative was 2-5 times more cost-efficient than surgery, in 31% of cases indistinguishable or up to 1.4 times more costly. Standard direct cost of the majority of AEP is reported using a methodology that enables easy application in other centers. For the most part, endoscopic procedures are more cost-efficient than the corresponding surgical procedure. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. Closing the gap: accelerating the translational process in nanomedicine by proposing standardized characterization techniques.

    Science.gov (United States)

    Khorasani, Ali A; Weaver, James L; Salvador-Morales, Carolina

    2014-01-01

    On the cusp of widespread permeation of nanomedicine, academia, industry, and government have invested substantial financial resources in developing new ways to better treat diseases. Materials have unique physical and chemical properties at the nanoscale compared with their bulk or small-molecule analogs. These unique properties have been greatly advantageous in providing innovative solutions for medical treatments at the bench level. However, nanomedicine research has not yet fully permeated the clinical setting because of several limitations. Among these limitations are the lack of universal standards for characterizing nanomaterials and the limited knowledge that we possess regarding the interactions between nanomaterials and biological entities such as proteins. In this review, we report on recent developments in the characterization of nanomaterials as well as the newest information about the interactions between nanomaterials and proteins in the human body. We propose a standard set of techniques for universal characterization of nanomaterials. We also address relevant regulatory issues involved in the translational process for the development of drug molecules and drug delivery systems. Adherence and refinement of a universal standard in nanomaterial characterization as well as the acquisition of a deeper understanding of nanomaterials and proteins will likely accelerate the use of nanomedicine in common practice to a great extent.

  8. Two-loop renormalization in the standard model, part II. Renormalization procedures and computational techniques

    Energy Technology Data Exchange (ETDEWEB)

    Actis, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Passarino, G. [Torino Univ. (Italy). Dipt. di Fisica Teorica; INFN, Sezione di Torino (Italy)

    2006-12-15

    In part I general aspects of the renormalization of a spontaneously broken gauge theory have been introduced. Here, in part II, two-loop renormalization is introduced and discussed within the context of the minimal Standard Model. Therefore, this paper deals with the transition between bare parameters and fields to renormalized ones. The full list of one- and two-loop counterterms is shown and it is proven that, by a suitable extension of the formalism already introduced at the one-loop level, two-point functions suffice in renormalizing the model. The problem of overlapping ultraviolet divergencies is analyzed and it is shown that all counterterms are local and of polynomial nature. The original program of 't Hooft and Veltman is at work. Finite parts are written in a way that allows for a fast and reliable numerical integration with all collinear logarithms extracted analytically. Finite renormalization, the transition between renormalized parameters and physical (pseudo-)observables, are discussed in part III where numerical results, e.g. for the complex poles of the unstable gauge bosons, are shown. An attempt is made to define the running of the electromagnetic coupling constant at the two-loop level. (orig.)

  9. Open Partial Nephrectomy in Renal Cancer: A Feasible Gold Standard Technique in All Hospitals

    Directory of Open Access Journals (Sweden)

    J. M. Cozar

    2008-01-01

    Full Text Available Introduction. Partial nephrectomy (PN is playing an increasingly important role in localized renal cell carcinoma (RCC as a true alternative to radical nephrectomy. With the greater experience and expertise of surgical teams, it has become an alternative to radical nephrectomy in young patients when the tumor diameter is 4 cm or less in almost all hospitals since cancer-specific survival outcomes are similar to those obtained with radical nephrectomy. Materials and Methods. The authors comment on their own experience and review the literature, reporting current indications and outcomes including complications. The surgical technique of open partial nephrectomy is outlined. Conclusions. Nowadays, open PN is the gold standard technique to treat small renal masses, and all nonablative techniques must pass the test of time to be compared to PN. It is not ethical for patients to undergo radical surgery just because the urologists involved do not have adequate experience with PN. Patients should be involved in the final treatment decision and, when appropriate, referred to specialized centers with experience in open or laparoscopic partial nephrectomies.

  10. Comparative analysis of photograph-based clinical goniometry to standard techniques.

    Science.gov (United States)

    Crasto, Jared A; Sayari, Arash J; Gray, Robert R-L; Askari, Morad

    2015-06-01

    Assessment of joint range of motion (ROM) is an accepted evaluation of disability as well as an indicator of recovery from musculoskeletal injuries. Many goniometric techniques have been described to measure ROM, with variable validity due to inter-rater reliability. In this report, we assessed the validity of photograph-based goniometry in measurement of ROM and its inter-rater reliability and compared it to two other commonly used techniques. We examined three methods for measuring ROM in the upper extremity: manual goniometry (MG), visual estimations (VE), and photograph-based goniometry (PBG). Eight motions of the upper extremity were measured in 69 participants at an academic medical center. We found visual estimations and photograph-based goniometry to be clinically valid when tested against manual goniometry (r avg. 0.58, range 0.28 to 0.87). Photograph-based measurements afforded a satisfactory degree of inter-rater reliability (ICC avg. 0.77, range 0.28 to 0.96). Our study supports photograph-based goniometry as the new standard goniometric technique, as it has been clinically validated, is performed with greater consistency and better inter-rater reliability when compared with manual goniometry. It also allows for better documentation of measurements and potential incorporation into medical records in direct contrast to visual estimation.

  11. MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG.

    Science.gov (United States)

    Dong, Li; Li, Fali; Liu, Qiang; Wen, Xin; Lai, Yongxiu; Xu, Peng; Yao, Dezhong

    2017-01-01

    Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero reference is still lacking. Here, we have therefore developed two open-source MATLAB toolboxes for REST of scalp EEG. One version of REST is closely integrated into EEGLAB, which is a popular MATLAB toolbox for processing the EEG data; and another is a batch version to make it more convenient and efficient for experienced users. Both of them are designed to provide an easy-to-use for novice researchers and flexibility for experienced researchers. All versions of the REST toolboxes can be freely downloaded at http://www.neuro.uestc.edu.cn/rest/Down.html, and the detailed information including publications, comments and documents on REST can also be found from this website. An example of usage is given with comparative results of REST and average reference. We hope these user-friendly REST toolboxes could make the relatively novel technique of REST easier to study, especially for applications in various EEG studies.

  12. The Effect of Using Cubing Technique Toward Writing Skill of Analytical Exposition Text of the Second Years Students at Mts Fathul Anwar Suka Maju

    OpenAIRE

    -, Zuraida; Rasyidah, Ummi; -, Eripuddin

    2015-01-01

    The purpose of the research was to find out the effect of cubing technique in students'writing skill of analytical exposition text. The findings showed that there is significant effectbetween teaching analyrical exposition text with using cubing technique. It can be seen of thevalue of t0(thitung) = 7,183 is bigger than tt(ttable) with significance 5%= 2,00 by using cubingtechnique..

  13. Thorium: one of the analytical techniques in neutronic activation and alpha spectrometry of the CDTN (Brazilian Nuclear Technology Development Center) in the last three decades

    International Nuclear Information System (INIS)

    Menezes, M.A.B.C.; Sabino, C.V.S.

    1994-01-01

    For long years, the CDTN (Brazilian Nuclear Technology Development Center ) has applied several analytical techniques in the thorium determination. This work is about the evolution of the neutronic activation in the thorium 232 analysis from the 1960's to now. The importance of the analysis request and alpha spectrometry for the thorium 228 and thorium 232 determination is emphasized. (J.A.M.M.)

  14. Are neck nodal volumes drawn on CT slices covered by standard three-field technique?

    Science.gov (United States)

    Sanguineti, Giuseppe; Culp, Laura R; Endres, Eugene J; Bayouth, John E

    2004-07-01

    Several definitions have been proposed in the past few years on how to contour the various neck nodal levels on CT slices. However, whether the resulting nodal volumes would have been covered by standard techniques is unknown. The purpose of this study was to clarify this issue. Eight patients (N0-N1) with head-and-neck cancer from various primary sites referred to us for definitive radiotherapy were included in this study. Two observers contoured the level Ib-V neck nodal volumes on planning CT according to seven reported definitions. Each observer also drew blocks on digitally reconstructed radiographs for the initial (on-cord) phase of a standard three-field technique (parallel opposed lateral fields and AP supraclavicular field) for three different clinical settings: "medium" larynx (to cover upper, mid, and low jugular nodes), "big" larynx (same as for medium, plus posterior cervical nodes), and "tonsil" (same as for big plus retropharyngeal nodes). Fields blocks were concentrically reduced 5 mm in all directions as a surrogate for the clinical target volume to planning target volume expansion. A plan was created for each of the clinical settings, delivering 2 Gy to the International Commission on Radiation Units and Measurements reference point. The coverage of the nodal levels according to the various definitions was investigated throughout the analysis of the volume receiving 50%, 80%, and 95% of the prescribed dose (V(50), V(80), and V(95), respectively) and dose covering at least 95% of the volume (D(95)) values extracted from their cumulative dose-volume histograms in the three clinical settings. The V(50) coverage of levels III and IV was adequate for all definitions and trials. For level V, about 3-5% of the volume was outside the 50% isodose of those trials that targeted the posterior cervical chain. Coverage of level Ib was highly dependent on the definition, with up to 21% of the volume outside the standard tonsillar fields. For level II, although

  15. Normalisation of conventional analytical methods (XRF And icp) on NAA using different kinds Of geological standard reference material

    International Nuclear Information System (INIS)

    Bounakhla, M.; Embarch, K.; Zahry, F.; Gaudry, A.; Piccot, D.; Gruffat, J.J.; Moutte, J.; Bilal, E.

    2001-01-01

    The aim of this work is the comparison between INAA (Instrumental Neutron Activation Analysis), XRF (X-ray Fluorescence) Analysis and ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry) methods for geological samples. The study had been done on 15 standard reference materials (SRM) of different kind of rocks having different origins. For INAA, the irradiation was made in Pierre-Sue Laboratory in France using two reactors, OSIRIS for irradiation with epithermal neutron and ORPHEE for thermal neutron irradiation. Two protocols of irradiation were performed, the first one under cadmium to eliminate thermal neutrons and the second one with a high flux ratio of thermal to epithermal neutrons (f=2000). Concerning XRF, we used two techniques : Energy Dispersive XRF and Wave-length XRF. The ICP-AES spectrometer used was a sequential. In this comparison study, we first normalized the INAA results on the certified values. The measurements of the conventional methods (XRF and ICP-AES) had been normalized on both of INAA results and the certified values. The function used in the fitting of the measured and certified values were a gaussian. It was concluded that both of the conventional methods complement in many cases the results of INAA, but their main disadvantage was poor sensitivity (especially for XRF) in the determination of trace elements, mainly rare elements. However, the conventional methods are necessary in rocks characterization throw major elements determination

  16. Investigation of size-fractionated urban aerosol and trace gases in Budapest by nuclear-related and other analytical techniques

    International Nuclear Information System (INIS)

    Salma, I.; Maenhaut, W.; Zemplen-Papp, E.; Bobvos, J.

    1998-01-01

    An air pollution study was conducted at two urban residential sites in Budapest (one representing the downtown, the other representing a wooded suburb) from 9 April till 17 May 1996. Size-fractionated aerosol samples were simultaneously collected on a daily basis, and meteorological conditions were recorded at both sampling sites. Stacked filter units (SFUs) with an upper size inlet cut-off were used as sampling device separating the urban aerosol into a coarse (about 10-2 μm equivalent aerodynamic diameter, EAD) and a fine ( 2 , SO 2 , CO and the total mass of the suspended particulate matter were measured every half hour at one of the sampling sites by commercial equipment. The SFU filters were analyzed by gravimetry for the total particle mass, by a light reflectance technique for black carbon, by particle-induced X-ray emission analysis and instrumental neutron activation analysis for elemental composition (in combination for up to 40-45 elements). The analytical results were used for characterizing the levels and the multi-elemental composition of the urban aerosol at both sampling sites and for both size fractions, for investigating the atmospheric concentrations and diurnal variation of some criteria pollutants, and for comparing the time-trends of aerosols and trace gases. Identification of the major source types of the aerosol fractions and trace gases, and assessment of the relative contribution from these sources are to be accomplished by multivariate receptor modeling. The present paper reports on the status of the air pollution study, and gives a discussion of the results

  17. A standardized infrared imaging technique that specifically detects UCP1-mediated thermogenesis in vivo.

    Science.gov (United States)

    Crane, Justin D; Mottillo, Emilio P; Farncombe, Troy H; Morrison, Katherine M; Steinberg, Gregory R

    2014-07-01

    The activation and expansion of brown adipose tissue (BAT) has emerged as a promising strategy to counter obesity and the metabolic syndrome by increasing energy expenditure. The subsequent testing and validation of novel agents that augment BAT necessitates accurate pre-clinical measurements in rodents regarding the capacity for BAT-derived thermogenesis. We present a novel method to measure BAT thermogenesis using infrared imaging following β3-adrenoreceptor stimulation in mice. We show that the increased body surface temperature observed using this method is due solely to uncoupling protein-1 (UCP1)-mediated thermogenesis and that this technique is able to discern differences in BAT activity in mice acclimated to 23 °C or thermoneutrality (30 °C). These findings represent the first standardized method utilizing infrared imaging to specifically detect UCP1 activity in vivo.

  18. Standardization of Berberis aristata extract through conventional and modern HPTLC techniques

    Directory of Open Access Journals (Sweden)

    Dinesh K. Patel

    2012-05-01

    Full Text Available Objective: Berberis aristata (Berberidaceae is an important medicinal plant, found in the different region of the world. It has significant medicinal value in the traditional Indian and Chinese system of medicine. The aim of the present investigation includes qualitative and quantitative analysis of Berberis aristata extract. Methods: Present study includes determination of phytochemical analysis, solubility test, heavy metal analysis, antimicrobial study and quantitative analysis by HPTLC method. Results: Preliminary phytochemical analysis showed the presence of carbohydrate, glycoside, alkaloid, protein, amino acid, saponin, tannin and flavonoid. Solubility in water and alcohal were found to be 81.90% in water and 84.52% in 50% in alcohal. Loss on drying was found to be 5.32%. Total phenol and flavonoid content were found to be 0.11% and 2.8%. Level of lead, arsenic, mercury and cadmium complies the standard level. E. coli and salmonella was found to be absent whereas total bacterial count, yeast and moulds contents were found to be under the limit. Content of berberine was found to be 13.47% through HPTLC techniques. Conclusions: The results obtained from the present studies could be used as source of valuable information which can play an important role for the food scientists, researchers and even the consumers for its standards.

  19. A standardized technique for high-pressure cooling of protein crystals.

    Science.gov (United States)

    Quirnheim Pais, David; Rathmann, Barbara; Koepke, Juergen; Tomova, Cveta; Wurzinger, Paul; Thielmann, Yvonne

    2017-12-01

    Cryogenic temperatures slow down secondary radiation damage during data collection from macromolecular crystals. In 1973, cooling at high pressure was identified as a method for cryopreserving crystals in their mother liquor [Thomanek et al. (1973). Acta Cryst. A29, 263-265]. Results from different groups studying different crystal systems indicated that the approach had merit, although difficulties in making the process work have limited its widespread use. Therefore, a simplified and reliable technique has been developed termed high-pressure cooling (HPC). An essential requirement for HPC is to protect crystals in capillaries. These capillaries form part of new sample holders with SPINE standard dimensions. Crystals are harvested with the capillary, cooled at high pressure (220 MPa) and stored in a cryovial. This system also allows the usage of the standard automation at the synchrotron. Crystals of hen egg-white lysozyme and concanavalin A have been successfully cryopreserved and yielded data sets to resolutions of 1.45 and 1.35 Å, respectively. Extensive work has been performed to define the useful working range of HPC in capillaries with 250 µm inner diameter. Three different 96-well crystallization screens that are most frequently used in our crystallization facility were chosen to study the formation of amorphous ice in this cooling setup. More than 89% of the screening solutions were directly suitable for HPC. This achievement represents a drastic improvement for crystals that suffered from cryoprotection or were not previously eligible for cryoprotection.

  20. Dosimetric comparison of intensity modulated radiotherapy techniques and standard wedged tangents for whole breast radiotherapy

    International Nuclear Information System (INIS)

    Fong, Andrew; Bromley, Regina; Beat, Mardi; Vien, Din; Dineley, Jude; Morgan, Graeme

    2009-01-01

    Full text: Prior to introducing intensity modulated radiotherapy (IMRT) for whole breast radiotherapy (WBRT) into our department we undertook a comparison of the dose parameters of several IMRT techniques and standard wedged tangents (SWT). Our aim was to improve the dose distribution to the breast and to decrease the dose to organs at risk (OAR): heart, lung and contralateral breast (Contra Br). Treatment plans for 20 women (10 right-sided and 10 left-sided) previously treated with SWT for WBRT were used to compare (a) SWT; (b) electronic compensators IMRT (E-IMRT); (c) tangential beam IMRT (T-IMRT); (d) coplanar multi-field IMRT (CP-IMRT); and (e) non-coplanar multi-field IMRT (NCP-IMRT). Plans for the breast were compared for (i) dose homogeneity (DH); (ii) conformity index (CI); (iii) mean dose; (iv) maximum dose; (v) minimum dose; and dose to OAR were calculated (vi) heart; (vii) lung and (viii) Contra Br. Compared with SWT, all plans except CP-IMRT gave improvement in at least two of the seven parameters evaluated. T-IMRT and NCP-IMRT resulted in significant improvement in all parameters except DH and both gave significant reduction in doses to OAR. As on initial evaluation NCP-IMRT is likely to be too time consuming to introduce on a large scale, T-IMRT is the preferred technique for WBRT for use in our department.

  1. Cost minimisation analysis of using acellular dermal matrix (Strattice™) for breast reconstruction compared with standard techniques.

    Science.gov (United States)

    Johnson, R K; Wright, C K; Gandhi, A; Charny, M C; Barr, L

    2013-03-01

    We performed a cost analysis (using UK 2011/12 NHS tariffs as a proxy for cost) comparing immediate breast reconstruction using the new one-stage technique of acellular dermal matrix (Strattice™) with implant versus the standard alternative techniques of tissue expander (TE)/implant as a two-stage procedure and latissimus dorsi (LD) flap reconstruction. Clinical report data were collected for operative time, length of stay, outpatient procedures, and number of elective and emergency admissions in our first consecutive 24 patients undergoing one-stage Strattice reconstruction. Total cost to the NHS based on tariff, assuming top-up payments to cover Strattice acquisition costs, was assessed and compared to the two historical control groups matched on key variables. Eleven patients having unilateral Strattice reconstruction were compared to 10 having TE/implant reconstruction and 10 having LD flap and implant reconstruction. Thirteen patients having bilateral Strattice reconstruction were compared to 12 having bilateral TE/implant reconstruction. Total costs were: unilateral Strattice, £3685; unilateral TE, £4985; unilateral LD and implant, £6321; bilateral TE, £5478; and bilateral Strattice, £6771. The cost analysis shows a financial advantage of using acellular dermal matrix (Strattice) in unilateral breast reconstruction versus alternative procedures. The reimbursement system in England (Payment by Results) is based on disease-related groups similar to that of many countries across Europe and tariffs are based on reported hospital costs, making this analysis of relevance in other countries. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. A Critical Appraisal of Techniques, Software Packages, and Standards for Quantitative Proteomic Analysis

    Science.gov (United States)

    Lawless, Craig; Hubbard, Simon J.; Fan, Jun; Bessant, Conrad; Hermjakob, Henning; Jones, Andrew R.

    2012-01-01

    Abstract New methods for performing quantitative proteome analyses based on differential labeling protocols or label-free techniques are reported in the literature on an almost monthly basis. In parallel, a correspondingly vast number of software tools for the analysis of quantitative proteomics data has also been described in the literature and produced by private companies. In this article we focus on the review of some of the most popular techniques in the field and present a critical appraisal of several software packages available to process and analyze the data produced. We also describe the importance of community standards to support the wide range of software, which may assist researchers in the analysis of data using different platforms and protocols. It is intended that this review will serve bench scientists both as a useful reference and a guide to the selection and use of different pipelines to perform quantitative proteomics data analysis. We have produced a web-based tool (http://www.proteosuite.org/?q=other_resources) to help researchers find appropriate software for their local instrumentation, available file formats, and quantitative methodology. PMID:22804616

  3. Flow Diversion versus Standard Endovascular Techniques for the Treatment of Unruptured Carotid-Ophthalmic Aneurysms.

    Science.gov (United States)

    Di Maria, F; Pistocchi, S; Clarençon, F; Bartolini, B; Blanc, R; Biondi, A; Redjem, H; Chiras, J; Sourour, N; Piotin, M

    2015-12-01

    Over the past few years, flow diversion has been increasingly adopted for the treatment of intracranial aneurysms, especially in the paraclinoid and paraophthalmic carotid segment. We compared clinical and angiographic outcomes and complication rates in 2 groups of patients with unruptured carotid-ophthalmic aneurysms treated for 7 years by either standard coil-based techniques or flow diversion. From February 2006 to December 2013, 162 unruptured carotid-ophthalmic aneurysms were treated endovascularly in 138 patients. Sixty-seven aneurysms were treated by coil-based techniques in 61 patients. Flow diverters were deployed in 95 unruptured aneurysms (77 patients), with additional coiling in 27 patients. Complication rates, clinical outcome, and immediate and long-term angiographic results were retrospectively analyzed. No procedure-related deaths occurred. Four procedure-related thromboembolic events (6.6%) leading to permanent morbidity in 1 case (1.6%) occurred in the coiling group. Neurologic complications were observed in 6 patients (7.8%) in the flow-diversion group, resulting in 3.9% permanent morbidity. No statistically significant difference was found between complication (P = .9) and morbidity rates (P = .6). In the coiling group (median follow-up, 31.5 ± 24.5 months), recanalization occurred at 1 year in 23/50 (54%) aneurysms and 27/55 aneurysms (50.9%) at the latest follow-up, leading to retreatment in 6 patients (9%). In the flow-diversion group (mean follow-up, 13.5 ± 10.8 months), 85.3% (35/41) of all aneurysms were occluded after 12 months, and 74.6% (50/67) on latest follow-up. The retreatment rate was 2.1%. Occlusion rates between the 2 groups differed significantly at 12 months (P < .001) and at the latest follow-up (P < .005). Our retrospective analysis shows better long-term occlusion of carotid-ophthalmic aneurysms after use of flow diverters compared with standard coil-based techniques, without significant differences in permanent morbidity

  4. Big data analytics from strategic planning to enterprise integration with tools, techniques, NoSQL, and graph

    CERN Document Server

    Loshin, David

    2013-01-01

    Big Data Analytics will assist managers in providing an overview of the drivers for introducing big data technology into the organization and for understanding the types of business problems best suited to big data analytics solutions, understanding the value drivers and benefits, strategic planning, developing a pilot, and eventually planning to integrate back into production within the enterprise. Guides the reader in assessing the opportunities and value propositionOverview of big data hardware and software architecturesPresents a variety of te

  5. Comparison of measured and calculated contralateral breast doses in whole breast radiotherapy for VMAT and standard tangent techniques

    International Nuclear Information System (INIS)

    Tse, T.L.J; Bromley, R.; Booth, J.; Gray, A.

    2011-01-01

    Full text: Objective This study aims to evaluate the accuracy of calculated dose with the Eclipse analytical anisotropic algorithm (AAA) for contralateral breast (CB) in left-sided breast radiotherapy for dual-arc VMA T and standard wedged tangent (SWT) techniques. Methods and materials Internal and surface CB doses were measured with EBT2 film in an anthropomorphic phantom mounted with C-cup and D-cup breasts. The measured point dose was approximated by averaging doses over the 4 x 4 mm 2 central region of each 2 x 2 cm2 piece of film. The dose in the target region of the breast was also measured. The measured results were compared to AAA calculations with calculation grids of I, 2.5 and 5 mm. Results In SWT plans, the average ratios of calculation to measurement for internal doses were 0.63 ± 0.081 and 0.5 I ± 0.28 in the medial and lateral aspects, respectively. Corresponding ratios for surface doses were 0.88 ± 0.22 and 0.38 ± 0.38. In VMAT plans, however, the calculation accuracies showed little dependence on the measurement locations, the ratios were 0.78 ± O. I I and 0.81 ± 0.085 for internal and surface doses. In general, finer calculation resolutions did not inevitably improve the dose estimates of internal doses. For surface doses, using smaller grid size I mm could improve the calculation accuracies on the medial but not the lateral aspects of CB. Conclusion In all plans, AAA had a tendency to underestimate both internal and surface CB doses. Overall, it produces more accurate results in VMAT than SWT plans.

  6. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.

    Science.gov (United States)

    Shaikh, M S; Moiz, B

    2016-04-01

    Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.

  7. The “excluding” suture technique for surgical closure of ventricular septal defects: A retrospective study comparing the standard technique

    Directory of Open Access Journals (Sweden)

    Roy Varghese

    2016-01-01

    Conclusion: Surgical closure of VSDs can be accomplished by placing sutures along the margins or away with comparable results. The incidence of CHB, however, seems to be less when the “excluding” technique is employed.

  8. Optimization of instrumental neutron activation analysis method by means of 2k experimental design technique aiming the validation of analytical procedures

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2013-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2 k experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  9. Enhancement of the dissolution profile of Tenoxicam by a solid dispersion technique and its analytical evaluation using HPLC.

    Science.gov (United States)

    Darwish, M K; Foad, M M

    2009-02-01

    The aim of the present study was to improve the dissolution, and therefore the bioavailability, of poorly water-soluble tenoxicam. Solid dispersions consisting of tenoxicam with two different types of polymers were prepared. The first type were PVP(30) and β-cyclodextrin and the second type were two superdisintegrants, explotab and croscarmellose sodium. A solid dispersion with an explotab ratio of 1:1 (F(8)) had the best dissolution profile compared to all of the prepared solid dispersions as well as the pure drug, which was then formulated into tablets (T(2)F(8)). T(2)F(8) had far better dissolution than commercial tablets, releasing only 28.3% of the drug, while T(2)F(8) exhibited 96.5% drug release in 20 min. T(2)F(8) was subjected to analytical validation as well as stability studies. The formulation was found to be stable after storage at 40°C for one month, 40°C and 75% relative humidity (40°C/75% RH) for one month, and 60°C for 15 days; this was confirmed by the absence of degraded product prepared in the laboratory by refluxing the drug with 1 N NaOH for 15 min. Infrared (IR) spectroscopy and differential scanning calorimetry (DSC) were performed on T(2)F(8) to identify physicochemical interactions between the drug and carrier, hence its effect on dissolution. A simple and rapid HPLC method was also developed to determine tenoxicam in human plasma and was then used in a pharmacokinetic study. Plasma samples were analyzed on a C(18) column with a mobile phase of 0.02 M sodium acetate:acetonitrile: methanol (7:2.5:0.5, v/v/v) and UV detection at 375 nm. The linear range of the plasma concentration was 1-16 μg/mL with a detection limit of 158 ng/mL. Within-day and between-day precision expressed as the relative standard deviation was less than 2%. The proposed method was successfully used in a bioequivalence study in healthy volunteers and mean pharmacokinetic parameters were calculated.

  10. Reduced Rate of Dehiscence After Implementation of a Standardized Fascial Closure Technique in Patients Undergoing Emergency Laparotomy

    DEFF Research Database (Denmark)

    Tolstrup, Mai-Britt; Watt, Sara Kehlet; Gögenur, Ismail

    2017-01-01

    is lacking. We aimed to investigate whether this technique would reduce the rate of dehiscence. METHODS: A standardized procedure of closing the midline laparotomy by using a "small steps" technique of continuous suturing with a slowly absorbable (polydioxanone) suture material in a wound-suture ratio...

  11. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  12. A study on environmental pollution monitoring and occupational health in the Capital Iron and Steel Company, Beijing, China, using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Chai Zhifang; Qian Qinfang; Feng Xiangqian; Ding Wenjun; Kuang Minxu; Wang Hongyu; Zhang Yongchen

    2000-01-01

    Since the First Research Coordination Meeting in Vienna, 20-24 October 1997, on the CRP on Assessment of Levels and Health-effects of Airborne Particulate Matter in Mining, Metal Refining and Metal Working Industries using Nuclear and related Analytical Techniques, our research group has completed the work plan defined by the contract with the Agency, including: (1) collection of airborne particulate, plant and soil samples from sites around the Capital Iron and Steel Company and of human hair, urine, and blood samples from the exposed workers and the control group; (2) validation of the analytical methods (NAA, XRF, SRXRF, JCP-AES etc.) by analyzing appropriate reference materials and by participating in relevant Agency's quality assurance exercises; and (3) analysis of part of the collected samples and preliminary discussion on the available analytical results. Finally, plan for future work was outlined as well. (author)

  13. [Abdominothoracic esophageal resection according to Ivor Lewis with intrathoracic anastomosis : standardized totally minimally invasive technique].

    Science.gov (United States)

    Runkel, N; Walz, M; Ketelhut, M

    2015-05-01

    The clinical and scientific interest in minimally invasive techniques for esophagectomy (MIE) are increasing; however, the intrathoracic esophagogastric anastomosis remains a surgical challenge and lacks standardization. Surgeons either transpose the anastomosis to the cervical region or perform hybrid thoracotomy for stapler access. This article reports technical details and early experiences with a completely laparoscopic-thoracoscopic approach for Ivor Lewis esophagectomy without additional thoracotomy. The extent of radical dissection follows clinical guidelines. Laparoscopy is performed with the patient in a beach chair position and thoracoscopy in a left lateral decubitus position using single lung ventilation. The anvil of the circular stapler is placed transorally into the esophageal stump. The specimen and gastric conduit are exteriorized through a subcostal rectus muscle split incision. The stapler body is placed into the gastric conduit and both are advanced through the abdominal mini-incision transhiatally into the right thoracic cavity, where the anastomosis is constructed. Data were collected prospectively and analyzed retrospectively. A total of 23 non-selected consecutive patients (mean age 69 years, range 46-80 years) with adenocarcinoma (n = 19) or squamous cell carcinoma (n = 4) were surgically treated between June 2010 and July 2013. Neoadjuvant therapy was performed in 15 patients resulting in 10 partial and 4 complete remissions. There were no technical complications and no conversions. Mean operative time was 305 min (range 220-441 min). The median lymph node count was 16 (range 4-42). An R0 resection was achieved in 91 % of patients and 3 anastomotic leaks occurred which were successfully managed endoscopically. There were no postoperative deaths. The intrathoracic esophagogastric anastomosis during minimally invasive Ivor Lewis esophagectomy can be constructed in a standardized fashion without an additional thoracotomy

  14. Standardization of MIP technique in three-dimensional CT portography: usefulness in evaluation of portosystemic collaterals in cirrhotic patients

    International Nuclear Information System (INIS)

    Kim, Jong Gi; Kim, Yong; Kim, Chang Won; Lee, Jun Woo; Lee, Suk Hong

    2003-01-01

    To assess the usefulness of three-dimensional CT portography using a standardized maximum intensity projection (MIP) technique for the evaluation of portosystemic collaterals in cirrhotic patients. In 25 cirrhotic patients with portosystemic collaterals, three-phase CT using a multide-tector-row helical CT scanner was performed to evaluate liver disease. Late arterial-phase images were transferred to an Advantage Windows 3.1 workstation (Gener Electric). Axial images were reconstructed by means of three-dimensional CT portography, using both a standardized and a non-standardized MIP technique, and the respective reconstruction times were determined. Three-dimensional CT portography with the standardized technique involved eight planes, namely the spleno-portal confluence axis (coronal, lordotic coronal, lordotic coronal RAO 30 .deg. C, and lordotic coronal LAO 30 .deg. C), the left renal vein axis (lordotic coronal), and axial MIP images (lower esophagus level, gastric fundus level and splenic hilum). The eight MIP images obtained in each case were interpreted by two radiologists, who reached a consensus in their evaluation. The portosystemic collaterals evaluated were as follows: left gastric vein dilatation; esophageal, paraesophageal, gastric, and splenic varix; paraumbilical vein dilatation; gastro-renal, spleno-renal, and gastro-spleno-renal shunt; mesenteric, retroperitoneal, and omental collaterals. The average reconstruction time using the non-standardized MIP technique was 11 minutes 23 seconds, and with the standardized technique, the time was 6 minutes 5 seconds. Three-dimensional CT portography with the standardized technique demonstrated left gastric vein dilatation (n=25), esophageal varix (n=18), paraesophageal varix (n=13), gastric varix (n=4), splenic varix (n=4), paraumbilical vein dilatation (n=4), gastro-renal shunt (n=3), spleno-renal shunt (n=3), and gastro-spleno-renal shunt (n=1). Using three-dimensional CT protography and the non-standardized

  15. Automated analytical standard production with supercritical fluid chromatography for the quantification of bioactive C17-polyacetylenes: a case study on food processing waste.

    Science.gov (United States)

    Bijttebier, Sebastiaan; D'Hondt, Els; Noten, Bart; Hermans, Nina; Apers, Sandra; Exarchou, Vassiliki; Voorspoels, Stefan

    2014-12-15

    Food processing enterprises produce enormous amounts of organic waste that contains valuable phytochemicals (e.g. C17-polyacetylenes). Knowledge on the phytochemicals content is a first step towards valorisation. Quantification of C17-polyacetylenes is however often hampered by the lack of commercially available standards or by tedious multistep in-house standard production procedures. In the current study, a new and straightforward supercritical fluid chromatography purification procedure is described for the simultaneous production of 2 analytical C17-polyacetylene standards. Respectively, 5 and 6 mg of falcarinol and falcarindiol were purified in 17 h on analytical scale. After confirming the identity and quality (97% purity) by Nuclear Magnetic Resonance, accurate mass-Mass Spectrometry (am-MS) and Photo Diode Array (PDA) detection the C17-polyacetylene standards were used for the analysis of industrial vegetable waste with Liquid Chromatography coupled to PDA and am-MS detection. Measurements showed varying concentrations of C17-polyacetylenes in the organic waste depending on its nature and origin. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Technique for approximate analytical calculating the internuclear cascade initiated by medium-energy nucleons in accelerator shields

    International Nuclear Information System (INIS)

    Kazarnovskij, M.V.; Matushko, G.K.; Matushko, V.L.; Par'ev, Eh.Ya.; Serezhnikov, S.V.

    1981-01-01

    The problem on propagation of the internuclear cascade initiated by nucleons of 0.1-1 GeV energy in accelerator schielding is solved approximately in the analytical form. Analytical expressions for the function of spatial, angular and energy distribution of the flux density of nucleons with the energy above 20 MeV and some functionals from it are obtained. The results of the calculations obtained by the developed methods are compared with calculations obtained by the method of direct simulation. It is shown that at the atomic mass of shielding material [ru

  17. Development, improvement and calibration of neutronic reaction rates measurements: elaboration of a standard techniques basis

    International Nuclear Information System (INIS)

    Hudelot, J.P.

    1998-06-01

    In order to improve and to validate the neutronics calculation schemes, perfecting integral measurements of neutronics parameters is necessary. This thesis focuses on the conception, the improvement and the development of neutronics reaction rates measurements, and aims at building a base of standard techniques. Two subjects are discussed. The first one deals with direct measurements by fission chambers. A short presentation of the different usual techniques is given. Then, those last ones are applied through the example of doubling time measurements on the EOLE facility during the MISTRAL 1 experimental programme. Two calibration devices of fission chambers are developed: a thermal column located in the central part of the MINERVE facility, and a calibration cell using a pulsed high flux neutron generator and based on the discrimination of the energy of the neutrons with a time-of-flight method. This second device will soon allow to measure the mass of fission chambers with a precision of about 1 %. Finally, the necessity of those calibrations will be shown through spectral indices measurements in core MISTRAL 1 (UO 2 ) and MISTRAL 2 (MOX) of the EOLE facility. In each case, the associated calculation schemes, performed using the Monte Carlo MCNP code with the ENDF-BV library, will be validated. Concerning the second one, the goal is to develop a method for measuring the modified conversion ratio of 238 U (defined as the ratio of 238 U capture rate to total fission rate) by gamma-ray spectrometry of fuel rods. Within the framework of the MISTRAL 1 and MISTRAL 2 programmes, the measurement device, the experimental results and the spectrometer calibration are described. Furthermore, the MCNP calculations of neutron self-shielding and gamma self-absorption are validated. It is finally shown that measurement uncertainties are better than 1 %. The extension of this technique to future modified conversion ratio measurements for 242 Pu (on MOX rods) and 232 Th (on

  18. Standardization of pulmonary ventilation technique using volume-controlled ventilators in rats with congenital diaphragmatic hernia

    Directory of Open Access Journals (Sweden)

    Rodrigo Melo Gallindo

    Full Text Available OBJECTIVE: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH using a volume-controlled ventilator. METHODS: Pregnant rats were divided into the following groups: a control (C; b exposed to nitrofen with CDH (CDH; and c exposed to nitrofen without CDH (N-. Fetuses of the three groups were randomly divided into the subgroups ventilated (V and non-ventilated (N-V. Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW, total lung weight (TLW, left lung weight (LLW, ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation. RESULTS: BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p 0.05. The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05. The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl. CONCLUSION: Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.

  19. Carbon and nitrogen determination in Zr by photon or proton activation analysis. Comparison between the results obtained by this method and other analytical techniques

    International Nuclear Information System (INIS)

    Petit, J.; Gosset, J.; Engelmann, C.

    1977-01-01

    Carbon and nitrogen are determined by the following nuclear reactions: 12 C(γ,n) 11 C and 14 N(p,α) 11 C. The performances of the method and the main interferences are considered. The process developed for the separation of carbon-11 from zirconium is described and its efficiency evaluated. The results obtained are compared with those given by different laboratories using various analytical techniques [fr

  20. Contribution of analytical nuclear techniques in the reconstruction of the Brazilian pre-history analysing archaeological ceramics of Tupiguarani tradition

    International Nuclear Information System (INIS)

    Faria, Gleikam Lopes de Oliveira; Menezes, Maria Angela de B.C.; Silva, Maria Aparecida

    2011-01-01

    Due to the high importance of the material vestiges for a culture of a nation, the Brazilian Council for Environment determined that the license to establish new enterprises are subjected to a technical report concerning environmental impact, including archaeological sites affected by that enterprise. Therefore, answering the report related to the Program for Prospection and Rescue of the Archaeological Patrimony of the Areas impacted by the installation of the Second Line of Samarco Mining Pipeline, the archaeological interventions were carried out along the coast of Espirito Santo. Tupi-Guarani Tradition vestiges were found there, where the main evidence was a interesting ceramics. Archaeology can fill the gap between ancient population and modern society elucidating the evidences found in archaeological sites. In this context, several ceramic fragments found in the archaeological sites - Hiuton and Bota-Fora - were analyzed by neutron activation technique, k 0-standardization method, at CDTN using the TRIGA MARK I IPR-R1 reactor, in order to characterize their elemental composition. The elements As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hf, K, La, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb, Zn and Zr were determined. Applying R software, a robust multivariate statistical analysis, the results pointed out that the pottery from the sites was made with clay from different sources. The X-ray powder diffraction analyses were carried out to determine the mineral composition and Moessbauer spectroscopy was applied to provide information on both the degree of burning and atmosphere in order to reconstruct the Indian burning strategies temperature used on pottery production. (author)

  1. Contribution of analytical nuclear techniques in the reconstruction of the Brazilian pre-history analysing archaeological ceramics of Tupiguarani tradition

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Gleikam Lopes de Oliveira; Menezes, Maria Angela de B.C.; Silva, Maria Aparecida, E-mail: menezes@cdtn.br, E-mail: cida@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Reator e Tecnicas Analiticas. Laboratorio de Ativacao Neutronica; Sabino, Claudia de V.S. [PUC-Minas, Belo Horizonte, MG (Brazil)

    2011-07-01

    Due to the high importance of the material vestiges for a culture of a nation, the Brazilian Council for Environment determined that the license to establish new enterprises are subjected to a technical report concerning environmental impact, including archaeological sites affected by that enterprise. Therefore, answering the report related to the Program for Prospection and Rescue of the Archaeological Patrimony of the Areas impacted by the installation of the Second Line of Samarco Mining Pipeline, the archaeological interventions were carried out along the coast of Espirito Santo. Tupi-Guarani Tradition vestiges were found there, where the main evidence was a interesting ceramics. Archaeology can fill the gap between ancient population and modern society elucidating the evidences found in archaeological sites. In this context, several ceramic fragments found in the archaeological sites - Hiuton and Bota-Fora - were analyzed by neutron activation technique, {sub k}0-standardization method, at CDTN using the TRIGA MARK I IPR-R1 reactor, in order to characterize their elemental composition. The elements As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hf, K, La, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb, Zn and Zr were determined. Applying R software, a robust multivariate statistical analysis, the results pointed out that the pottery from the sites was made with clay from different sources. The X-ray powder diffraction analyses were carried out to determine the mineral composition and Moessbauer spectroscopy was applied to provide information on both the degree of burning and atmosphere in order to reconstruct the Indian burning strategies temperature used on pottery production. (author)

  2. Exploring the Efficacy of Behavioral Skills Training to Teach Basic Behavior Analytic Techniques to Oral Care Providers

    Science.gov (United States)

    Graudins, Maija M.; Rehfeldt, Ruth Anne; DeMattei, Ronda; Baker, Jonathan C.; Scaglia, Fiorella

    2012-01-01

    Performing oral care procedures with children with autism who exhibit noncompliance can be challenging for oral care professionals. Previous research has elucidated a number of effective behavior analytic procedures for increasing compliance, but some procedures are likely to be too time consuming and expensive for community-based oral care…

  3. Modification of the cranial closing wedge ostectomy technique for the treatment of canine cruciate disease. Description and comparison with standard technique.

    Science.gov (United States)

    Wallace, A M; Addison, E S; Smith, B A; Radke, H; Hobbs, S J

    2011-01-01

    To describe a modification of the cranial closing wedge ostectomy (CCWO) technique and to compare its efficacy to the standard technique on cadaveric specimens. The standard and modified CCWO technique were applied to eight pairs of cadaveric tibiae. The following parameters were compared following the ostectomy: degrees of plateau levelling achieved (degrees), tibial long axis shift (degrees), reduction in tibial length (mm), area of bone wedge removed (cm²), and the area of proximal fragment (cm²). The size of the removed wedge of bone and the reduction in tibial length were significantly less with the modified CCWO technique. The modified CCWO has two main advantages. Firstly a smaller wedge is removed, allowing a greater preservation of bone stock in the proximal tibia, which is advantageous for implant placement. Secondly, the tibia is shortened to a lesser degree, which might reduce the risk of recurvatum, fibular fracture and patella desmitis. These factors are particularly propitious for the application of this technique to Terrier breeds with excessive tibial plateau angle, where large angular corrections are required. The modified CCWO is equally effective for plateau levelling and results in an equivalent tibial long-axis shift. A disadvantage with the modified technique is that not all of the cross sectional area of the distal fragment contributes to load sharing at the osteotomy.

  4. Standardization of the PCR technique for the detection of delta toxin in Staphylococcus spp.

    Directory of Open Access Journals (Sweden)

    C. Marconi

    2005-06-01

    Full Text Available Coagulase-negative staphylococci (CNS, components of the normal flora of neonates, have emerged as important opportunistic pathogens of nosocomial infections that occur in neonatal intensive care units. Some authors have reported the ability of some CNS strains, particularly Staphylococcus epidermidis, to produce a toxin similar to S. aureus delta toxin. This toxin is an exoprotein that has a detergent action on the membranes of various cell types resulting in rapid cell lysis. The objectives of the present study were to standardize the Polymerase Chain Reaction (PCR technique for the detection of the gene responsible for the production of delta toxin (hld gene in staphylococcal species isolated from catheters and blood cultures obtained from neonates, and to compare the results to those obtained with the phenotypic synergistic hemolysis method. Detection of delta toxin by the phenotypic and genotypic method yielded similar results for the S. aureus isolates. However, in S. epidermidis, a higher positivity was observed for PCR (97.4% compared to the synergistic hemolysis method (86.8%. Among CNS, S. epidermidis was the most frequent isolate and was a delta toxin producer. Staphylococcus simulans and S. warneri tested positive by the phenotypic method, but their positivity was not confirmed by PCR for the hld gene detection. These results indicate that different genes might be responsible for the production of this toxin in different CNS species, requiring highly specific primers for their detection. PCR was found to be a rapid and reliable method for the detection of the hld gene in S. aureus and S. epidermidis.

  5. Analytical quadrics

    CERN Document Server

    Spain, Barry; Ulam, S; Stark, M

    1960-01-01

    Analytical Quadrics focuses on the analytical geometry of three dimensions. The book first discusses the theory of the plane, sphere, cone, cylinder, straight line, and central quadrics in their standard forms. The idea of the plane at infinity is introduced through the homogenous Cartesian coordinates and applied to the nature of the intersection of three planes and to the circular sections of quadrics. The text also focuses on paraboloid, including polar properties, center of a section, axes of plane section, and generators of hyperbolic paraboloid. The book also touches on homogenous coordi

  6. "Heidelberg standard examination" and "Heidelberg standard procedures" - Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education.

    Science.gov (United States)

    Nikendei, C; Ganschow, P; Groener, J B; Huwendiek, S; Köchel, A; Köhl-Hackert, N; Pjontek, R; Rodrian, J; Scheibe, F; Stadler, A-K; Steiner, T; Stiepak, J; Tabatabai, J; Utz, A; Kadmon, M

    2016-01-01

    The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties.

  7. Comparison of anthropometry with photogrammetry based on a standardized clinical photographic technique using a cephalostat and chair.

    Science.gov (United States)

    Han, Kihwan; Kwon, Hyuk Joon; Choi, Tae Hyun; Kim, Jun Hyung; Son, Daegu

    2010-03-01

    The aim of this study was to standardize clinical photogrammetric techniques, and to compare anthropometry with photogrammetry. To standardize clinical photography, we have developed a photographic cephalostat and chair. We investigated the repeatability of the standardized clinical photogrammetric technique. Then, with 40 landmarks, a total of 96 anthropometric measurement items was obtained from 100 Koreans. Ninety six photogrammetric measurements from the same subjects were also obtained from standardized clinical photographs using Adobe Photoshop version 7.0 (Adobe Systems Corporation, San Jose, CA, USA). The photogrammetric and anthropometric measurement data (mm, degree) were then compared. A coefficient was obtained by dividing the anthropometric measurements by the photogrammetric measurements. The repeatability of the standardized photography was statistically significantly high (p=0.463). Among the 96 measurement items, 44 items were reliable; for these items the photogrammetric measurements were not different to the anthropometric measurements. The remaining 52 items must be classified as unreliable. By developing a photographic cephalostat and chair, we have standardized clinical photogrammetric techniques. The reliable set of measurement items can be used as anthropometric measurements. For unreliable measurement items, applying a suitable coefficient to the photogrammetric measurement allows the anthropometric measurement to be obtained indirectly.

  8. An appraisal of neutron activation analysis and other analytical techniques for the determination of arsenic, selenium and tin in environmental samples

    International Nuclear Information System (INIS)

    Peterson, P.J.; Girling, C.A.; Klumpp, D.W.; Minski, M.J.

    1979-01-01

    The paper presents an experimental comparison between neutron activation analysis, atomic absorption spectrophotometry and fluorescence spectrophotometry used for the determination of trace amounts of As, Se and Sn and the other two analytical techniques mentioned. Gamma-ray spectrometry has been used to determine 76 As (tsub(1/2)=26.3 h) after 1 day's irradiation at a thermal neutron flux of 1.6x10 12 n.cm -2 .s -1 . High sensitivity was also obtained using an atomic absorption spectrophotometer coupled with covalent hydride generation. Advantages of the latter technique include simplicity of operation, high speed of analysis and negligible background correction. When used in conjuction with selective reduction and a cold-trap this method quantitatively distinguishes between the valence states and some methylated derivatives. Selenium has been analysed by gamma-ray spectrometry using 77 Sesup(m) (tsub(1/2)=17.5 s) after cyclic activation at a thermal neutron flux of 2x10 12 n.cm -2 .s -1 . Atomic absorption spectrophotometry following hydride generation, or fluorescence spectrophotometry of the 2,3 diaminonaphthalene complex constitute additional sensitive analytical methods for the determination of Se. These have the added advantage that valence states can be selectively measured. Low concentrations of Sn have been determined by neutron activation analysis and by spectrophotometric techniques using phenylfluorone as the complexing reagent, but these methods depend on selective extraction of Sn(IV) iodide. Whilst maintaining high sensitivity, these problems were avoided by using the hydride generation technique with an atomic absorption spectrophotometer. Comparative analytical values for Bowen's kale and NBS orchard leaves are presented

  9. Analysis of vitamin D metabolic markers by mass spectrometry: current techniques, limitations of the "gold standard" method, and anticipated future directions.

    Science.gov (United States)

    Volmer, Dietrich A; Mendes, Luana R B C; Stokes, Caroline S

    2015-01-01

    Vitamin D compounds belong to a group of secosteroids, which occur naturally as vitamin D3 in mammals and D2 in plants. Vitamin D is vital for bone health but recent studies have shown a much wider role in the pathologies of diseases such as diabetes, cancer, autoimmune, neurodegenerative, mental and cardiovascular diseases. Photosynthesis of vitamin D in the human skin and subsequent hepatic and renal metabolism generate a wide range of transformation products occurring over a large dynamic range spanning from picomolar to nanomolar levels. This necessitates selective and sensitive analytical methods to quantitatively capture these low concentration levels in relevant tissues such as blood. Ideally, vitamin D assessment would be performed using a universal and standardized analytical method available to clinical laboratories that provides reliable and accurate quantitative results for all relevant vitamin D metabolites with sufficiently high throughput. At present, LC-MS/MS assays are the most promising techniques for vitamin D analysis. The present review focuses on developments in mass spectrometry methodologies of the past 12 years. It will highlight detrimental influences of the biological matrix, epimer contributions, pitfalls of specific mass spectrometry data acquisition routines (in particular multiple reaction monitoring, MRM), influence of ionization source, derivatization reactions, inter-laboratory comparisons on precision, accuracy, and application range of vitamin D metabolites. © 2013 Wiley Periodicals, Inc.

  10. Dissolved Silver in Marine Waters: Reviewing Three Decades of Advances in Analytical Techniques and Understanding its Biogeochemical Cycling

    Science.gov (United States)

    Ndungu, K.; Flegal, A. R., Jr.

    2015-12-01

    Although billions of dollars have been spent over the past half-century to reduce contamination of U.S. waters, quantifying parts-per-billion reductions in surface water concentration since has been relatively unsuccessful. The reasons for the failure in identifying the benefits of these remediative efforts include: (i) historic (pre-1980) problems in accurately sampling and analyzing trace element concentrations at parts-per-billion level, so that temporal reductions in trace metal contamination reflected improved sampling and analytical accuracy rather than real decreases in those concentrations; (ii) limited seasonal and long term research. Silver in its ionic form is more toxic to aquatic organisms than any other metal except Hg. Because Ag is not common naturally in the environment, its elevated presence in water, sediment or biological tissues is usually indicative of anthropogenic influences. However, there is very little published data on Ag levels in both water and sediment. The published studies include Ag levels in a few U.S. estuarine waters, including detailed and time series studies for the San Francisco Estuary system by the WIGS lab at UC Santa Cruz. In the open Ocean, Ag measurements are limited to a few studies in the North and South Pacific, The North and South Atlantic. However, as Gallon and Flegal recently noted, there is no available data on Ag concentrations from the Indian Ocean! Most of the dissolved Ag data from the Atlantic was made in WIGS lab at UC Santa Cruz Analytical determination of Ag in seawater has come a long way since Murozumi reported the first dissolved Ag measurements from the N. Pacific in 1981 using isotope dilution MS after solvent extraction. In this presentation I will review analytical developments for Ag determination in the last three decades. I will also highlight the missing data gaps and present new tentative data on dissolved Ag concentration and cycling in polar regions including the Antarctic (Amundsen Sea

  11. A REVIEW ON THE ANALYTICAL TECHNIQUES USED FOR THE DETERMINATION OF PARACETAMOL IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS

    OpenAIRE

    Aisha Noreen; Kiran Qadeer; Zubair Anwar; Iqbal Ahmad

    2016-01-01

    Paracetamol (PM) is an active metabolite of phenacetin and belongs to p-aminophenol derivatives. It is also termed as acetaminophen. PM is one of the non-steroidal anti-inflammatory drugs (NSAIDs) which is used as an analgesic and antipyretic agent. It is an OTC drug and is used as a common household analgesic. It is not used as a substitute of aspirin or any other NSAIDs. It is a weak cyclooxygenase (COX) 1 and 2 inhibitor but may inhibit COX-3 in the central nervous system. Many analytical ...

  12. Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to his particular situation the fundamental procedures of the following techniques. 1.1.1 Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy. 1.1.2 Standard comparison technique using pure gold, or gold-aluminum alloy, and 1.1.3 Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy. 1.2 The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-...

  13. Toward an international standard for PCR-based detection of food-borne thermotolerant Campylobacters: Assay development and analytical validation

    DEFF Research Database (Denmark)

    Lübeck, Peter Stephensen; Wolffs, P.; On, Stephen L.W.

    2003-01-01

    As part of a European research project (FOOD-PCR), we developed a standardized and robust PCR detection assay specific for the three most frequently reported food-borne pathogenic Campylobacter species, C. jejuni, C. coli, and C. lari. Fifteen published and unpublished PCR primers targeting the 16S...... carcass rinse, unlike both Taq DNA polymerase and DyNAzyme. Based on these results, Tth was selected as the most suitable enzyme for the assay. The standardized PCR test described shows potential for use in large-scale screening programs for food-borne Campylobacter species under the assay conditions....... The inclusivity and exclusivity were 100 and 97%, respectively. In an attempt to find a thermostable DNA polymerase more resistant than Taq to PCR inhibitors present in chicken samples, three DNA polymerases were evaluated. The DNA polymerase Tth was not inhibited at a concentration of 2% (vol/vol) chicken...

  14. Introduction to analytical techniques of beam-target interactions and resolutions; Introduction aux techniques d`analyse interactions rayonnement-matiere et resolutions

    Energy Technology Data Exchange (ETDEWEB)

    Ruste, J.

    1995-08-01

    For several years, new analysis and observation techniques have been developed, which have considerably improved material research. Almost all these techniques are based on the interaction of a beam of `primary particles` (electrons, photons, ions, particles, etc) with target. Correct and appropriate use of these techniques requires a good knowledge of these interactions and their consequences (emissions of `secondary particles`, modifications of the primary beam and target, etc). The first part of this report deals with the radiation/material interactions according to the nature of the radiation and its energy. The nature and consequences of the interaction of an electromagnetic wave, a beam of electrons, ions and neutrons are examined over an extended range of energy from MeV to MeV. Certain notions such as the analysis area, spatial resolutions or limits of detection can also be defined. In the second part, some of the most important and widespread techniques of analysis and observation are compared in terms of properties and performance. In particular, there is a brief principle of the technique, nature of the data obtained, spatial resolution, and the limits of detection with today`s methods permit. (author). 5 refs., 23 figs., 9 tabs.

  15. Toward an International Standard for PCR-Based Detection of Food-Borne Thermotolerant Campylobacters: Assay Development and Analytical Validation

    OpenAIRE

    Lübeck, P. S.; Wolffs, P.; On, S. L. W.; Ahrens, P.; Rådström, P.; Hoorfar, J.

    2003-01-01

    As part of a European research project (FOOD-PCR), we developed a standardized and robust PCR detection assay specific for the three most frequently reported food-borne pathogenic Campylobacter species, C. jejuni, C. coli, and C. lari. Fifteen published and unpublished PCR primers targeting the 16S rRNA gene were tested in all possible pairwise combinations, as well as two published primers targeting the 23S rRNA gene. A panel of 150 strains including target an...

  16. [Health protection for rural workers: the need to standardize techniques for quantifying dermal exposure to pesticides].

    Science.gov (United States)

    Selmi, Giuliana da Fontoura Rodrigues; Trapé, Angelo Zanaga

    2014-05-01

    Quantification of dermal exposure to pesticides in rural workers, used in risk assessment, can be performed with different techniques such as patches or whole body evaluation. However, the wide variety of methods can jeopardize the process by producing disparate results, depending on the principles in sample collection. A critical review was thus performed on the main techniques for quantifying dermal exposure, calling attention to this issue and the need to establish a single methodology for quantification of dermal exposure in rural workers. Such harmonization of different techniques should help achieve safer and healthier working conditions. Techniques that can provide reliable exposure data are an essential first step towards avoiding harm to workers' health.

  17. Standard techniques for presentation and analysis of crater size-frequency data. [on moon and planetary surfaces

    Science.gov (United States)

    Arvidson, R.; Boyce, J.; Chapman, C.; Cintala, M.; Fulchignoni, M.; Moore, H.; Soderblom, L.; Neukum, G.; Schultz, P.; Strom, R.

    1979-01-01

    In September 1977 a crater studies workshop was held for the purpose of developing standardized data analysis and presentation techniques. The present report contains the unanimous recommendations of the participants. Recommendations are devoted primarily to crater size-frequency data and refer to cumulative and relative size-frequency distribution plots and to morphological analysis.

  18. Portable optical frequency standard based on sealed gas-filled hollow-core fiber using a novel encapsulation technique

    DEFF Research Database (Denmark)

    Triches, Marco; Brusch, Anders; Hald, Jan

    2015-01-01

    A portable stand-alone optical frequency standard based on a gas-filled hollow-core photonic crystal fiber is developed to stabilize a fiber laser to the 13C2H2 P(16) (ν1 + ν3) transition at 1542 nm using saturated absorption. A novel encapsulation technique is developed to permanently seal...

  19. Neutron Capture Radiography: Neutron Capture Radiography:a technique for isotopic labelling and analytical imaging with a few stable isotopes

    Directory of Open Access Journals (Sweden)

    Michel Thellier

    2006-01-01

    Full Text Available NCR (neutron capture radiography may be used successfully for the imaging of one of the stable isotopes of a few chemical elements (especially 6Li and 10B, possibly also 14N, 17O, and others and for labelling experiments using these stable isotopes. Other physical techniques compete with NCR. However, NCR can remain extremely useful in a certain number of cases, because it is usually more easily done and is less expensive than the other techniques.

  20. Neutron Capture Radiography: Neutron Capture Radiography:a technique for isotopic labelling and analytical imaging with a few stable isotopes

    OpenAIRE

    Thellier, Michel; Ripoll, Camille

    2006-01-01

    NCR (neutron capture radiography) may be used successfully for the imaging of one of the stable isotopes of a few chemical elements (especially 6Li and 10B, possibly also 14N, 17O, and others) and for labelling experiments using these stable isotopes. Other physical techniques compete with NCR. However, NCR can remain extremely useful in a certain number of cases, because it is usually more easily done and is less expensive than the other techniques.

  1. [Comparison study on polymerase chain reaction (PCR) and standard culture technique in detecting mycobacterium tuberculosis to diagnose of joint tuberculosis].

    Science.gov (United States)

    Sun, Yong-sheng; Wen, Jian-min; Lü, Wei-xin; Lou, Si-quan; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin; Duan, Yong-zhuang

    2009-07-01

    To study the role of PCR technique in detection of mycobacterium tuberculosis in the samples from joint tuberculosis, and to evaluate the clinical value of PCR in diagnosis of joint tuberculosis. From June 1993 to August 2001, PCR was used to detect DNA of mycobacterium tuberculosis, and the standard culture was applied to detect mycobacterium tuberculosis. Mycobacterium tuberculosis were respectively blindly by the two techniques in the samples obtained from 95 patients with joint tuberculosis (55 males and 40 females, the age ranging from 2 to 75 years, with an average of 34 years). The positive rate of mycobacterium tuberculosis detection was calculated. In the detection of mycobacterium tuberculosis, positive rate was 82% (78/95) in PCR technique, and 16% (15/95) in standard culture technique. There were statistical differences between the two groups (chi2=67, Ptechnique is a rapid, simple, sensitive and specific method for detection of mycobacterium tuberculosis in the samples of joint tuberculosis, showing more marked advantages than the standard culture technique. It is valuable in the early rapid diagnosis and differential diagnosis of joint tuberculosis.

  2. Towards an international standard for PCR-based detection of food-borne thermotolerant Campylobacters: assay development and analytical validation.

    OpenAIRE

    Lübeck, P S; Wolffs, Petra; On, S L; Ahrens, P; Rådström, Peter; Hoorfar, J

    2003-01-01

    As part of a European research project (FOOD-PCR), we developed a standardized and robust PCR detection assay specific for the three most frequently reported food-borne pathogenic Campylobacter species, C. jejuni, C. coli, and C. lari. Fifteen published and unpublished PCR primers targeting the 16S rRNA gene were tested in all possible pairwise combinations, as well as two published primers targeting the 23S rRNA gene. A panel of 150 strains including target and nontarget strains was used in ...

  3. Rapid Quantification of Melamine in Different Brands/Types of Milk Powders Using Standard Addition Net Analyte Signal and Near-Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Bang-Cheng Tang

    2016-01-01

    Full Text Available Multivariate calibration (MVC and near-infrared (NIR spectroscopy have demonstrated potential for rapid analysis of melamine in various dairy products. However, the practical application of ordinary MVC can be largely restricted because the prediction of a new sample from an uncalibrated batch would be subject to a significant bias due to matrix effect. In this study, the feasibility of using NIR spectroscopy and the standard addition (SA net analyte signal (NAS method (SANAS for rapid quantification of melamine in different brands/types of milk powders was investigated. In SANAS, the NAS vector of melamine in an unknown sample as well as in a series of samples added with melamine standards was calculated and then the Euclidean norms of series standards were used to build a straightforward univariate regression model. The analysis results of 10 different brands/types of milk powders with melamine levels 0~0.12% (w/w indicate that SANAS obtained accurate results with the root mean squared error of prediction (RMSEP values ranging from 0.0012 to 0.0029. An additional advantage of NAS is to visualize and control the possible unwanted variations during standard addition. The proposed method will provide a practically useful tool for rapid and nondestructive quantification of melamine in different brands/types of milk powders.

  4. A note on the solution of general Falkner-Skan problem by two novel semi-analytical techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Khidir

    2015-12-01

    Full Text Available The aim of this paper is to give a presentation of two new iterative methods for solving non-linear differential equations, they are successive linearisation method and spectral homotopy perturbation method. We applied these techniques on the non-linear boundary value problems of Falkner-Skan type. The methods used to find a recursive former for higher order equations that are solved using the Chebyshev spectral method to find solutions that are accurate and converge rapidly to the full numerical solution. The methods are illustrated by progressively applying the technique to the Blasius boundary layer equation, the Falkner-Skan equation and finally, the magnetohydrodynamic (MHD Falkner-Skan equation. The solutions are compared to other methods in the literature such as the homotopy analysis method and the spectral-homotopy analysis method with focus on the accuracy and convergence of this new techniques.

  5. Model Standards and Techniques for Control of Radon in New Residential Buildings

    Science.gov (United States)

    This document is intended to serve as a model for use to develop and adopt building codes, appendices to codes, or standards specifically applicable to unique local or regional radon control requirements.

  6. Olive oil authentication: A comparative analysis of regulatory frameworks with especial emphasis on quality and authenticity indices, and recent analytical techniques developed for their assessment. A review.

    Science.gov (United States)

    Bajoub, Aadil; Bendini, Alessandra; Fernández-Gutiérrez, Alberto; Carrasco-Pancorbo, Alegría

    2018-03-24

    Over the last decades, olive oil quality and authenticity control has become an issue of great importance to consumers, suppliers, retailers, and regulators in both traditional and emerging olive oil producing countries, mainly due to the increasing worldwide popularity and the trade globalization of this product. Thus, in order to ensure olive oil authentication, various national and international laws and regulations have been adopted, although some of them are actually causing an enormous debate about the risk that they can represent for the harmonization of international olive oil trade standards. Within this context, this review was designed to provide a critical overview and comparative analysis of selected regulatory frameworks for olive oil authentication, with special emphasis on the quality and purity criteria considered by these regulation systems, their thresholds and the analytical methods employed for monitoring them. To complete the general overview, recent analytical advances to overcome drawbacks and limitations of the official methods to evaluate olive oil quality and to determine possible adulterations were reviewed. Furthermore, the latest trends on analytical approaches to assess the olive oil geographical and varietal origin traceability were also examined.

  7. Role of sediment-trace element chemistry in water-quality monitoring and the need for standard analytical methods

    Science.gov (United States)

    Horowitz, Arthur J.

    1991-01-01

    Multiple linear regression models calculated from readily obtainable chemical and physical parameters can explain a high percentage (70% or greater) of observed sediment trace-element variance for Cu, Zn, Pb, Cr, Ni, Co, As, Sb, Se, and Hg. Almost all the factors used in the various models fall into the category of operational definitions (e.g., grain size, surface area, and geochemical substrates such as amorphous iron and manganese oxides). Thus, the concentrations and distributions used in the various models are operationally defined, and are subject to substantial change depending on the method used to determine them. Without standardized procedures, data from different sources are not comparable, and the utility and applicability of the various models would be questionable.

  8. Evaluation of the overlapping of posterior teeth in two techniques of improved interproximal panoramic program and standard panoramic

    Directory of Open Access Journals (Sweden)

    Goodarzi pour D

    2010-06-01

    Full Text Available "nBackground and Aims: Overlapping of the proximal surfaces of posterior teeth in the panoramic radiography is a major concern. Therefore, an option has been developed in the panoramic unit of Planmeca Promax, namely improved interproximal mode. This mode causes lower horizental angle with the teeth contact region during the unit rotation decreasing overlapping of the panoramic images of the posterior teeth especially premolar teeth. The present study was done to compare the overlapping of posterior teeth using two techniques of improved interproximal panoramic program and standard panoramic. "nMaterials and Methods: In this diagnostic study, 32 patients requiring panoramic radiographies at their posterior teeth during their routine diagnosis and treatment process with the mean age of 27.3 years were participated. No patients showed crowding of posterior teeth or missed and restored posterior teeth. The participants' panoramic radiographies were randomly taken by two techniques of improved interproximal panoramic and standard panoramic using Planmeca Promax device. The overlapping of the panoramic images was blindly assessed by an oral radiologist. The overlapping in both techniques was reported by frequency and percentage. The comparisons were done by Chi-square test between two techniques and the odds ratio of overlapping was estimated using regression analysis. "nResults: In standard panoramic techniques, 38.5% (148 contacts of 384 contacts of the proximal surfaces overlapped while the overlapping of the proximal surfaces was observed in 18.8% (72 contacts of 384 overall contacts in improved interproximal technique. Significant differences were noted between two techniques regarding overlapping (P<0.001. Also 66.4% and 39.1% of 4-5 teeth contacts overlapped in standard and improved techniques. The values were reported to be 39.1% and 12.5% in contacts of 5-6 teeth and 10.2% and 4.7% in the contacts of 6-7 teeth in both techniques

  9. Theory of stochastic differential equations with jumps and applications mathematical and analytical techniques with applications to engineering

    CERN Document Server

    SITU, Rong

    2005-01-01

    Derivation of Ito's formulas, Girsanov's theorems and martingale representation theorem for stochastic DEs with jumpsApplications to population controlReflecting stochastic DE techniqueApplications to the stock market. (Backward stochastic DE approach)Derivation of Black-Scholes formula for market with and without jumpsNon-linear filtering problems with jumps.

  10. Remnant preservation in anterior cruciate ligament reconstruction versus standard techniques: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Ma, Tianjun; Zeng, Chun; Pan, Jianying; Zhao, Chang; Fang, Hang; Cai, Daozhang

    2017-01-01

    Preserving the remnant during anterior cruciate ligament (ACL) reconstruction is considered beneficial for graft healing, but it might increase the technical difficulties and complications. This study was to compare outcomes of using the technique of remnant preservation during the ACL reconstruction versus the standard procedure with the debridement of remnant. We searched PubMed and EMBASE and the Cochrane Library for randomized controlled trials comparing the outcomes of ACL reconstruction both with and without remnant preservation. The risk of bias was assessed in accordance with the Cochrane Collaboration's risk of bias tool. Meta-analysis was performed to compare results. Six randomized controlled trials with 346 patients were included. Statistically significant differences in favor of using technique of remnant preservation were observed for Lysholm Score, arthrometer measurements, and tibial tunnel enlargement. There was no significant difference between remnant technique of preservation and the standard procedure with respect to the IKDC (International Knee Documentation Committee) grade, IKDC score, Lachman Test, Pivot-shift Test, range of motion (ROM), and the incidence of the cyclops lesion. This meta-analysis of randomized controlled trials showed that ACL reconstruction with technique of remnant preservation cannot provide superior clinical outcomes compared with the standard procedure.

  11. Development of the double-pulse technique to improve the analytical performance of Laser Induced Breakdown Spectroscopy (LIBS) on solids: Nuclear and geological applications

    International Nuclear Information System (INIS)

    Gautier, C.

    2005-10-01

    The double-pulse technique has been developed to improve the analytical performance of Laser Ablation coupled to Optical Emission Spectroscopy (LA/OES). This approach relies on the addition of a second time-resolved laser pulse to the classical LA/OES system. It has been studied on aluminium alloys according to different geometries of the two laser beams (orthogonal and collinear geometries) before being applied to different materials (synthetic glass, rock, steel, sodium chloride). The increase in emission intensity depends on the temporal parameters, on the excitation energy level of the emission line, on the concentration of the studied element and on the analyzed matrix. The double-pulse LA/OES technique can be particularly interesting to improve the sensitivity towards vitreous matrices containing elements emitting lines with high excitation energy levels. (author)

  12. Synthesis and analytics of 2,2,3,4,4-d5-19-nor-5alpha-androsterone--an internal standard in doping analysis.

    Science.gov (United States)

    Gaertner, Peter; Bica, Katharina; Felzmann, Wolfgang; Forsdahl, Guro; Gmeiner, Günter

    2007-05-01

    A short and efficient synthesis of pentadeuterated 2,2,3,4,4-d5-19-nor-5alpha-androsterone 7 starting from 19-norandrost-4-ene-3,17-dione 1 by a d1-L-Selectride mediated stereo- and regioselective reduction of the 3-keto group is presented. The use of compound 7 as internal standard for the detection of anabolic steroids via mass spectrometric techniques such as gas chromatography-mass spectrometry (GC-MS) is discussed.

  13. Standard practice for examination of welds using the alternating current field measurement technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice describes procedures to be followed during alternating current field measurement examination of welds for baseline and service-induced surface breaking discontinuities. 1.2 This practice is intended for use on welds in any metallic material. 1.3 This practice does not establish weld acceptance criteria. 1.4 The values stated in either inch-pound units or SI units are to be regarded separately as standard. The values stated in each system might not be exact equivalents; therefore, each system shall be used independently of the other. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Development of an analytical model for the determination of 60Co in aqueous samples by atomic absorption and gamma spectrometry techniques

    International Nuclear Information System (INIS)

    Solis A, N. A.

    2015-01-01

    The applications of the nuclear energy in industry and medicine generate radioactive wastes that must be isolated and confined in order to limit its spread in the biosphere. These types of wastes are generated in hospitals, industry, research centers and nuclear power plants (during de fuel cycle). The radioactive elements (radionuclides) cannot be destroyed by any known method, either chemical or mechanical. Its final destruction is produced by radioactive decay, which makes them stable isotopes, or nuclear transmutation being bombarded with atomic particles. Consequently, the radioactive waste management is to control the radioactive discharges and reduce to tolerable limits, eliminating of effluents and wastes the radionuclides of interest, concentrating them so they can be stored or evacuated so that later not appear in dangerous concentration in the biosphere. In Mexico, the main generators of radioactive wastes are the nuclear power plant of Laguna Verde in Veracruz, Hospitals of the public and private sector, in addition Instituto Nacional de Investigaciones Nucleares (ININ) some institutes and facilities of the UNAM and Instituto Politecnico Nacional (IPN) and industries among others. The aqueous radioactive wastes, particularly those from the nuclear power plants contain traces of cobalt-60. Currently there is no model or analytical technique for the separation of this radionuclide, so it became necessary to develop an analytical model for separation and facilitate their disposal. In this paper was shown that atomic absorption and gamma spectrometry techniques can separate the active concentration of the inactive, which is important because the total concentration can be associated through direct relationships with the wear of metal parts of the nuclear reactor, since the metal alloys of the same reactor containing a fraction of cobalt. Also this analytical and mathematical model that can be reproducible and applicable to full sets of samples and that this

  15. Relationship between alveolar bone measured by 125I absorptiometry with analysis of standardized radiographs: 2. Bjorn technique

    International Nuclear Information System (INIS)

    Ortman, L.F.; McHenry, K.; Hausmann, E.

    1982-01-01

    The Bjorn technique is widely used in periodontal studies as a standardized measure of alveolar bone. Recent studies have demonstrated the feasibility of using 125 I absorptiometry to measure bone mass. The purpose of this study was to compare 125 I absorptiometry with the Bjorn technique in detecting small sequential losses of alveolary bone. Four periodontal-like defects of incrementally increasing size were produced in alveolar bone in the posterior segment of the maxilla of a human skull. An attempt was made to sequentially reduce the amount of bone in 10% increments until no bone remained, a through and through defect. The bone remaining at each step was measured using 125 I absorptiometry. At each site the 125 I absorptiometry measurements were made at the same location by fixing the photon source to a prefabricated precision-made occlusal splint. This site was just beneath the crest and midway between the borders of two adjacent teeth. Bone loss was also determined by the Bjorn technique. Standardized intraoral films were taken using a custom-fitted acrylic clutch, and bone measurements were made from the root apex to coronal height of the lamina dura. A comparison of the data indicates that: (1) in early bone loss, less than 30%, the Bjorn technique underestimates the amount of loss, and (2) in advanced bone loss, more than 60% the Bjorn technique overestimates it

  16. Applying Standard Independent Verification and Validation (IVV) Techniques Within an Agile Framework: Is There a Compatibility Issue?

    Science.gov (United States)

    Dabney, James B.; Arthur, James Douglas

    2017-01-01

    Agile methods have gained wide acceptance over the past several years, to the point that they are now a standard management and execution approach for small-scale software development projects. While conventional Agile methods are not generally applicable to large multi-year and mission-critical systems, Agile hybrids are now being developed (such as SAFe) to exploit the productivity improvements of Agile while retaining the necessary process rigor and coordination needs of these projects. From the perspective of Independent Verification and Validation (IVV), however, the adoption of these hybrid Agile frameworks is becoming somewhat problematic. Hence, we find it prudent to question the compatibility of conventional IVV techniques with (hybrid) Agile practices.This paper documents our investigation of (a) relevant literature, (b) the modification and adoption of Agile frameworks to accommodate the development of large scale, mission critical systems, and (c) the compatibility of standard IVV techniques within hybrid Agile development frameworks. Specific to the latter, we found that the IVV methods employed within a hybrid Agile process can be divided into three groups: (1) early lifecycle IVV techniques that are fully compatible with the hybrid lifecycles, (2) IVV techniques that focus on tracing requirements, test objectives, etc. are somewhat incompatible, but can be tailored with a modest effort, and (3) IVV techniques involving an assessment requiring artifact completeness that are simply not compatible with hybrid Agile processes, e.g., those that assume complete requirement specification early in the development lifecycle.

  17. Various analytical techniques used for the measurement of isotopic purity of heavy water at Madras Atomic Power Station

    International Nuclear Information System (INIS)

    Satyanarayanan, V.; Umapathy, P.; Bhaskaran, R.; Nagarajan, J.; Pradeep, Jeena; Ayyar, S.R.

    2008-01-01

    The paper deals with the various techniques used for the measurement of isotopic purity of heavy water samples received from different sources viz. reactor systems, heavy water upgrading plant and fresh consignment from heavy water production plants. Heavy water is used in PHWRs as moderator and primary coolant. Isotopic Purity is an important parameter to be monitored/analysed regularly for both the systems. There is a minimum isotopic purity level to be maintained in the moderator system due to neutron economy/fuel burnup and in the case of coolant system the measurement is of paramount importance due to its safety considerations. The selection of the method of analysis depends on the isotopic range. The techniques used to measure the isotopic purity of heavy water are a) Infrared Spectrophotometry b) Refractometry c) Densitometry. Infrared spectrometer uses the property of molecular absorption of IR radiation by HOD species and the absorbance is the measure of isotopic purity. This technique is generally used for measuring high isotopic (80-99.98%) and low isotopic samples. Refractometer uses the property of refractive index of heavy water. The difference in refractive indices of light water and heavy water is 0.0048. A 1 % change in D 2 O concentration would thus equal to 0.000048 refractive index units. This method is used for determining the approximate isotopic value of a sample. Density meter uses the property of difference in densities of light and heavy water. The difference in density of 99.999% D 2 O and light water is 0.107540 which covers the whole range of interest. The experience gained with these techniques in the measurements of isotopic purity of various samples are presented in this paper. (author)

  18. Comparison of 4 analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs

    OpenAIRE

    2011-01-01

    Abstract Different techniques for the determination of total tin in beverage and canned food by atomic spectrometry were compared. The performance characteristics of Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Hydride Generation Inductively Coupled Plasma Atomic Emission Spectrometry (HG-ICP-AES), Electrothermal Atomization Atomic Absorption Spectrometry (ETA-AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) were determined in term of linearity, ...

  19. Background air pollution studies in urban and rural areas of Bangladesh using nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Khan, A.H.; Khaliquzzaman, M.; Tarafdar, S.A.; Biswas, S.K.; Islam, A.

    1994-01-01

    The trace element constituents of aerosols such as Hg, Pb, Cd, Se, As, Cu, Zn, Cr, V, etc. are permanent pollutants affecting the biosphere and the general ecosystem. The measurements of these elements collected on air filters, in rainwater, and also in some bioindicators such as moss and lichen, can yield very significant information on the origin, transport, removal and deposition of these pollutants. A set of sensitive and precise nuclear-related and chemical methods such as PIXE, EDXRF, FAAS and DPASV have, therefore, been developed and applied to analyze a number of trace and minor elements in air particulates, coal fly ash, plant materials, moss and water. Further analytical developments would include INAA and TRXRF. Some of the results from air particulates (integral), coal fly ash and moss analyses are presented to illustrate the experience level of the Laboratory. A core programme of study on the trace element composition of aerosols from urban and rural atmosphere in Bangladesh has been planned for implementation within the framework of this CRP. 10 refs, 1 fig., 5 tabs

  20. A Novel Environmental Performance Evaluation of Thailand’s Food Industry Using Structural Equation Modeling and Fuzzy Analytic Hierarchy Techniques

    Directory of Open Access Journals (Sweden)

    Anirut Pipatprapa

    2016-03-01

    Full Text Available Currently, the environment and sustainability are important topics for every industry. The food industry is particularly complicated in this regard because of the dynamic and complex character of food products and their production. This study uses structural equation modeling (SEM and a fuzzy analytic hierarchy process (FAHP to investigate which factors are suitable for evaluating the environmental performance of Thailand’s food industry. A first-stage questionnaire survey was conducted with 178 managers in the food industry that obtained a certificate from the Department of Industrial Work of Thailand to synthesize the performance measurement model and the significance of the relationship between the indicators. A second-stage questionnaire measured 18 experts’ priorities regarding the criteria and sub-factors involved in the different aspects and assessment items regarding environmental performance. SEM showed that quality management, market orientation, and innovation capability have a significantly positive effect on environmental performance. The FAHP showed that the experts were most concerned about quality management, followed by market orientation and innovation capability; the assessment items for quality policy, quality assurance, and customer orientation were of the most concern. The findings of this study can be referenced and support managerial decision making when monitoring environmental performance.

  1. MIMO wireless networks channels, techniques and standards for multi-antenna, multi-user and multi-cell systems

    CERN Document Server

    Clerckx, Bruno

    2013-01-01

    This book is unique in presenting channels, techniques and standards for the next generation of MIMO wireless networks. Through a unified framework, it emphasizes how propagation mechanisms impact the system performance under realistic power constraints. Combining a solid mathematical analysis with a physical and intuitive approach to space-time signal processing, the book progressively derives innovative designs for space-time coding and precoding as well as multi-user and multi-cell techniques, taking into consideration that MIMO channels are often far from ideal. Reflecting developments

  2. Free-field reciprocity calibration of laboratory standard (LS) microphones using a time selective technique

    DEFF Research Database (Denmark)

    Rasmussen, Knud; Barrera Figueroa, Salvador

    2006-01-01

    Although the basic principle of reciprocity calibration of microphones in a free field is simple, the practical problems are complicated due to the low signal-to-noise ratio and the influence of cross talk and reflections from the surroundings. The influence of uncorrelated noise can be reduced...... by conventional narrow-band filtering and time averaging, while correlated signals like cross talk and reflections can be eliminated by using time-selective postprocessing techniques. The technique used at DPLA overcomes both these problems using a B&K Pulse analyzer in the SSR mode (steady state response......) and an FFT-based time-selective technique. The complex electrical transfer impedance is measured in linear frequency steps from a few kHz to about three times the resonance frequency of the microphones. The missing values at low frequencies are estimated from a detailed knowledge of the pressure...

  3. R2SM: a package for the analytic computation of the R{sub 2} Rational terms in the Standard Model of the Electroweak interactions

    Energy Technology Data Exchange (ETDEWEB)

    Garzelli, M.V. [INFN (Italy); Granada Univ. (Spain). Dept. de Fisica Teorica y del Cosmos y CAFPE; Malamos, I. [Radboud Universiteit Nijmegen, Department of Theoretical High Energy Physics, Institute for Mathematics, Astrophysics and Particle Physics, Nijmegen (Netherlands)

    2011-03-15

    The analytical package written in FORM presented in this paper allows the computation of the complete set of Feynman Rules producing the Rational terms of kind R{sub 2} contributing to the virtual part of NLO corrections in the Standard Model of the Electroweak interactions. Building block topologies filled by means of generic scalars, vectors and fermions, allowing to build these Feynman Rules in terms of specific elementary particles, are explicitly given in the R{sub {xi}} gauge class, together with the automatic dressing procedure to obtain the Feynman Rules from them. The results in more specific gauges, like the 't Hooft Feynman one, follow as particular cases, in both the HV and the FDH dimensional regularization schemes. As a check on our formulas, the gauge independence of the total Rational contribution (R{sub 1}+R{sub 2}) to renormalized S-matrix elements is verified by considering the specific example of the H {yields}{gamma}{gamma} decay process at 1-loop. This package can be of interest for people aiming at a better understanding of the nature of the Rational terms. It is organized in a modular way, allowing a further use of some its files even in different contexts. Furthermore, it can be considered as a first seed in the effort towards a complete automation of the process of the analytical calculation of the R{sub 2} effective vertices, given the Lagrangian of a generic gauge theory of particle interactions. (orig.)

  4. Comparison of spectrum normalization techniques for univariate ...

    Indian Academy of Sciences (India)

    Laser-induced breakdown spectroscopy; univariate study; normalization models; stainless steel; standard error of prediction. Abstract. Analytical performance of six different spectrum normalization techniques, namelyinternal normalization, normalization with total light, normalization with background along with their ...

  5. The Effect of Long-Term Therapeutics, Prophylaxis and Screening Techniques on Aircrew Medical Standards.

    Science.gov (United States)

    1981-03-01

    350. voel RA, Kirch DC, LeFree MT, Rainwater JO, Jensen DP, Steele PP. Thallium-201 myocardial perfusion scintiaraphy: results of standard aad multi...Reference 3. Further Reference 4.Security Clasification of Document A;ARD4"P-3 10 ISBN 92-835-0288-4 UNCLASSIFIE) 5 Originator Advi,,ory Group for

  6. Identification of heavy metals sources in the Mexico city atmosphere, using the proton induced x-ray analytical technique and multifactorial statistics techniques

    International Nuclear Information System (INIS)

    Hernandez M, B.

    1997-01-01

    The objectives of this work are: to identify the heavy metals present in the air, and its concentrations. To know the behavior from the polluting chemical elements to the long of an annual cycle corresponding to 1990, based on the concentrations of the same ones, obtained through the PIXE technique. To identify the suitable statistical methods to use to the data of metals concentration in form of total suspended particle (PST), found in this investigation. To relate the concentrations and the meteorological parameters considered to be able to suggest the possible pollution sources. In function of the obtained results, to serve as base to the decisions making and measures control that are planned by diverse institutions focused to the problem of the atmospheric pollution in the Metropolitan area of Mexico City (ZMCM). (Author)

  7. Admissions Standards and the Use of Key Marketing Techniques by United States' Colleges and Universities.

    Science.gov (United States)

    Goldgehn, Leslie A.

    1989-01-01

    A survey of admissions deans and directors investigated the use and perceived effectiveness of 15 well-known marketing techniques: advertising, advertising research, a marketing plan, market positioning, market segmentation, marketing audit, marketing research, pricing, program and service accessibility, program development, publicity, target…

  8. Laser Induced Breakdown Spectroscopy compared with conventional plasma optical emission techniques for the analysis of metals - A review of applications and analytical performance

    Science.gov (United States)

    Bengtson, A.

    2017-08-01

    This review is focused on a comparison of LIBS with the two most common plasma Optical Emission Spectroscopy (OES) techniques for analysis of metals; spark OES and glow discharge (GD) OES. It is shown that these two techniques have only minor differences in analytical performance. An important part of the paper reviews a direct comparison of the analytical figures of merit for bulk analysis of steels using spark and LIBS sources. The comparison was carried out using one instrument with interchangeable sources, eliminating differences related to the optical system and detectors. It was found that the spark provides slightly better analytical figures of merit. The spark analysis is considerably faster, the simple design of the spark stand has enabled complete automation, both properties of great importance in the metallurgical industry for routine analysis. The analysis of non-metallic inclusions (NMI) with spark and LIBS is presented, in the case of the spark this has become known as Pulse Distribution Analysis (PDA). A very significant difference between the techniques is that the electrical spark typically evaporates 100 times more material than a single laser pulse, resulting in complete evaporation of an NMI present in the evaporated metal. The major advantage of LIBS is that it is localised with very good lateral resolution. The major advantages of spark is that it is much faster (can be done simultaneous with the bulk analysis) and easier to quantify. Compositional Depth Profiling (CDP) is compared for GD-OES and LIBS. It is shown that for applications where GD-OES is well suited, e.g. coated metallic sheet, GD-OES still performs slightly better than LIBS. Similar to the case of NMI analysis, the major advantage of LIBS is the great lateral resolution. This allows elemental surface mapping, as well as CDP of very small areas on μm scale. One further advantage of LIBS is that samples of almost any material, shape and size can be analysed, whereas GD-OES has

  9. Emerging analytical separation techniques with high throughput potential for pharmaceutical analysis, part I: Stationary phase and instrumental developments in LC.

    Science.gov (United States)

    Pieters, Sigrid; Dejaegher, Bieke; Vander Heyden, Yvan

    2010-07-01

    In recent years, a trend of change has been observed within pharmaceutical industry. As modern drug discovery has reached a remarkable level of complexity and drugs need to be discovered, developed and produced against strict timelines and within cost- and regulatory constraints, industry seeks "lean" solutions to increase productivity. Among them, increasing the sample throughput of the ever-growing number of necessary (routine) analyses has become a popular target to cut precious time. For the last thirty years, High-Performance Liquid Chromatography (HPLC) has been the leading technology when it comes to various analyses in pharmaceutical industry; however, its necessity of serial analyses taking typically 10-45 min has been a sample throughput-limiting barrier. Lately, the fundamentals of HPLC have been exploited to raise new technologies that can speed up analyses to ground breaking limits, without compromising separation efficiency. This paper reviews some promising technologies, i.e. totally porous sub-2microm particles accompanied by pressures up to 1000 bar (Ultra-Performance Liquid Chromatography or UPLC), fused-core particle technology, monolithic supports and High Temperature Liquid Chromatography (HTLC), having the potential to take LC to the next level in pharmaceutical industry. As each analytical method has its own demands, the advances of the above technologies are discussed for different applications in pharmaceutical analysis where high-throughput analysis can be meaningful, i.e. in a drug discovery and development setting, and in quality operations. Both chemical and biological pharmaceuticals are considered. We discuss the perspectives of these technologies and their realizations up to now in high-throughput pharmaceutical analysis.

  10. Analytical study of the effects of soft tissue artefacts on functional techniques to define axes of rotation.

    Science.gov (United States)

    De Rosario, Helios; Page, Álvaro; Besa, Antonio

    2017-09-06

    The accurate location of the main axes of rotation (AoR) is a crucial step in many applications of human movement analysis. There are different formal methods to determine the direction and position of the AoR, whose performance varies across studies, depending on the pose and the source of errors. Most methods are based on minimizing squared differences between observed and modelled marker positions or rigid motion parameters, implicitly assuming independent and uncorrelated errors, but the largest error usually results from soft tissue artefacts (STA), which do not have such statistical properties and are not effectively cancelled out by such methods. However, with adequate methods it is possible to assume that STA only account for a small fraction of the observed motion and to obtain explicit formulas through differential analysis that relate STA components to the resulting errors in AoR parameters. In this paper such formulas are derived for three different functional calibration techniques (Geometric Fitting, mean Finite Helical Axis, and SARA), to explain why each technique behaves differently from the others, and to propose strategies to compensate for those errors. These techniques were tested with published data from a sit-to-stand activity, where the true axis was defined using bi-planar fluoroscopy. All the methods were able to estimate the direction of the AoR with an error of less than 5°, whereas there were errors in the location of the axis of 30-40mm. Such location errors could be reduced to less than 17mm by the methods based on equations that use rigid motion parameters (mean Finite Helical Axis, SARA) when the translation component was calculated using the three markers nearest to the axis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Ancient artefacts and modern analytical techniques - Usefulness of laser ablation ICP-MS demonstrated with ancient gold coins

    Energy Technology Data Exchange (ETDEWEB)

    Junk, Stephan A. E-mail: staj@ww.tu-freiberg.de

    2001-07-01

    Laser ablation (LA) is a sampling technique which is well suited for the characterization of precious archaeological artefacts. Using the example of Celtic gold coins - so-called 'Regenbogenschuesselchen' - the benefits of LA attached to an inductively coupled plasma mass spectrometry (ICP-MS) with a sector field mass spectrometer and multiple Faraday detectors are reviewed. It will be shown that osmium isotopic ratios determined by this method are a valuable guide for investigations on the provenance of Celtic gold. The precision and accuracy achieved with LA-ICP-MS are discussed. Corrections for chemical interferences and mass bias are exemplified.

  12. Application of Nuclear Analytical Techniques in Elemental Characterization of Wadi El-Nakhil Alabaster, Central Eastern Desert, Egypt

    OpenAIRE

    Zain M. Alamoudi; A. El-Taher

    2016-01-01

    Instrumental neutron activation analysis (INAA) is a powerful technique for trace element determination in rocks. Nine alabaster samples were collected from Wadi El-Nakhil located at the intersection of lat. 26°10′50′′N and long. 34°03′40′′E, central Eastern Desert, Egypt, for investigation by INAA and Energy Depressive X-Ray Fluorescence (EDXRF). The samples were irradiated by thermal neutrons at the TRIGA Mainz research reactor at a neutron flux of 7 × 1011 n/cm2·s. Twenty-two elements were...

  13. Inversion of the amplitude of the two-dimensional analytic signal of the magnetic anomaly by the particle swarm optimization technique

    Science.gov (United States)

    Srivastava, Shalivahan; Agarwal, B. N. P.

    2010-08-01

    Amplitude of the 2-D analytic signal of the magnetic anomaly profile is independent of the directions of the Earth's magnetic field vector and remnant magnetization of the causative source. It exhibits peaks corresponding to the locations of the corners of a causative source, modelled by say a polygon. It also exhibits a peak corresponding to different idealized source geometries related to the structural indices. This amplitude is computed from the first-order horizontal and vertical derivatives of the observed magnetic anomaly and is relatively less noisy than second-order derivatives. The amplitude can also be computed directly from the measured derivatives. Particle swarm optimization (PSO)-a global optimization technique is applied to interpret this amplitude in terms of the horizontal location and depth, constant (related to magnetization) and various source geometries through structural indices. Applicability of the proposed technique is evaluated through the analyses of simulated magnetic anomalies (noise-free and corrupted with 20 per cent random noise) over different types of source geometries, namely, a thin dyke and a contact with high accuracy in parameter estimation. Studies on the choices of search parameter space reveal that a relatively wide search space can be assigned. Practical applicability of the proposed technique has been demonstrated through three magnetic anomaly profiles digitized from published literature. The results of PSO, Euler deconvolution, enhanced local wavenumber and drill hole are comparable. PSO results also seem to be more stable than other techniques.

  14. International intercomparison of standards for low collision kerma rates in air by means of low dose TLD techniques

    International Nuclear Information System (INIS)

    Spanne, P.; Carlsson, C.A.; Carlsson, G.A.

    1984-01-01

    An international intercomparison of standards for calibration of radiation protection instruments is described. The intercomparison involved collision kerma rates in air in the range 5.7 to 7.400 μGy.h -1 and was performed using low dose TLD techniques with TL-LiF dosemeters. The dosemeters were specifically tested with regard to their dose rate dependence, but none was found. (author)

  15. Identifying and Prioritizing Effective Factors on Classifying A Private Bank Customers by Delphi Technique and Analytical Hierarchy Process (AHP

    Directory of Open Access Journals (Sweden)

    S. Khayatmoghadam

    2013-05-01

    Full Text Available Banking industry development and presence of different financial institutions cause to increase competition in customer and their capitals attraction so that there are about 28 banks and many credit and financial institutions from which 6 banks are public and 22 banks are private. Among them, public banks have a more appropriate situation than private banks with regard to governmental relations and support and due to geographical expansion and longer history. But due to lack of above conditions; private banks try to attract customers with regarding science areas to remedy this situation. Therefore, in this study we are decided to review banking customers from a different viewpoint. For this reason, we initially obtained ideal indications from banking viewpoint in two-story of uses and resources customers using experts and Delphi technique application which based on this, indicators such as account workflow, account average, lack of returned cheque, etc and in uses section, the amount of facility received, the amount of received warranties, etc, were determined. Then, using a Hierarchical Analysis (AHP method and experts opinions through software Expert Choice11, priority of these criteria were determined and weight of each index was determined. It should be noted that statistical population of bank experts associated with this study were queue and staff. Also obtained results can be used as input for customer grouping in line with CRM techniques implementation.

  16. Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy: An analytical technique to understand therapeutic responses at the molecular level.

    Science.gov (United States)

    Kalmodia, Sushma; Parameswaran, Sowmya; Yang, Wenrong; Barrow, Colin J; Krishnakumar, Subramanian

    2015-11-16

    Rapid monitoring of the response to treatment in cancer patients is essential to predict the outcome of the therapeutic regimen early in the course of the treatment. The conventional methods are laborious, time-consuming, subjective and lack the ability to study different biomolecules and their interactions, simultaneously. Since; mechanisms of cancer and its response to therapy is dependent on molecular interactions and not on single biomolecules, an assay capable of studying molecular interactions as a whole, is preferred. Fourier Transform Infrared (FTIR) spectroscopy has become a popular technique in the field of cancer therapy with an ability to elucidate molecular interactions. The aim of this study, was to explore the utility of the FTIR technique along with multivariate analysis to understand whether the method has the resolution to identify the differences in the mechanism of therapeutic response. Towards achieving the aim, we utilized the mouse xenograft model of retinoblastoma and nanoparticle mediated targeted therapy. The results indicate that the mechanism underlying the response differed between the treated and untreated group which can be elucidated by unique spectral signatures generated by each group. The study establishes the efficiency of non-invasive, label-free and rapid FTIR method in assessing the interactions of nanoparticles with cellular macromolecules towards monitoring the response to cancer therapeutics.

  17. Evaluation of a standard breast tangent technique: a dose-volume analysis of tangential irradiation using three-dimensional tools

    International Nuclear Information System (INIS)

    Krasin, Matthew; McCall, Anne; King, Stephanie; Olson, Mary; Emami, Bahman

    2000-01-01

    Purpose: A thorough dose-volume analysis of a standard tangential radiation technique has not been published. We evaluated the adequacy of a tangential radiation technique in delivering dose to the breast and regional lymphatics, as well as dose delivered to underlying critical structures. Methods and Materials: Treatment plans of 25 consecutive women with breast cancer undergoing lumpectomy and adjuvant breast radiotherapy were studied. Patients underwent two-dimensional (2D) treatment planning followed by treatment with standard breast tangents. These 2D plans were reconstructed without modification on our three-dimensional treatment planning system and analyzed with regard to dose-volume parameters. Results: Adequate coverage of the breast (defined as 95% of the target receiving at least 95% of the prescribed dose) was achieved in 16 of 25 patients, with all patients having at least 85% of the breast volume treated to 95% of the prescribed dose. Only 1 patient (4%) had adequate coverage of the Level I axilla, and no patient had adequate coverage of the Level II axilla, Level III axilla, or the internal mammary lymph nodes. Conclusion: Three-dimensional treatment planning is superior in quantification of the dose received by the breast, regional lymphatics, and critical structures. The standard breast tangent technique delivers an adequate dose to the breast but does not therapeutically treat the regional lymph nodes in the majority of patients. If coverage of the axilla or internal mammary lymph nodes is desired, alternate beam arrangements or treatment fields will be necessary

  18. Phytochemical analysis and standardization of Strychnos nux-vomica extract through HPTLC techniques

    Directory of Open Access Journals (Sweden)

    Dinesh Kumar Patel

    2012-05-01

    Full Text Available Objective: The objective is to develop a noval qualitative and quantitative method by which we can determine different phytoconstituents of Strychnos nux-vomica L. Methods: To profile the phyconstituents of Strychnos nux-vomica, in the present study hydroalcoholic extract of Strychnos nux-vomica was subjected to preliminary phytochemical analysis, antimicrobial activities against certain pathogenic microorganisms, solubility test, loss on drying and pH value. Extract was also subjected to the quantitative analysis including total phenol, flavonoid and heavy metal analysis. Quantitative analysis was performed through HPTLC methods using strychnine and brucine as a standard marker. Results: Phytochemical analysis revealed the presence of alkaloid, carbohydrate, tannin, steroid, triterpenoid and glycoside in the extract. Total flavonoid and phenol content of Strychnos nux-vomica L extract was found to be 0.40 % and 0.43%. Result showed that the level of heavy metal (lead, arsenic, mercury and cadmium complie the standard level. Total bacterial count, yeast and moulds contents were found to be under the limit whereas E. coli and salmonella was found to be absent in the extract. Content of strychnine and brucine were found to be 4.75% and 3.91%. Conclusions: These studies provide valluable information for correct identification and selection of the drug from various adulterations. In future this study will be helpful for the quantitative analysis as well as standardization of the Strychnos nux-vomica L.

  19. Investigation of preparation techniques for δ2H analysis of keratin materials and a proposed analytical protocol

    Science.gov (United States)

    Qi, H.; Coplen, T.B.

    2011-01-01

    Accurate hydrogen isotopic measurements of keratin materials have been a challenge due to exchangeable hydrogen in the sample matrix and the paucity of appropriate isotopic reference materials for calibration. We found that the most reproducible δ2HVSMOW-SLAP and mole fraction of exchangeable hydrogen, x(H)ex, of keratin materials were measured with equilibration at ambient temperature using two desiccators and two different equilibration waters with two sets of the keratin materials for 6 days. Following equilibration, drying the keratin materials in a vacuum oven for 4 days at 60 °C was most critical. The δ2H analysis protocol also includes interspersing isotopic reference waters in silver tubes among samples in the carousel of a thermal conversion elemental analyzer (TC/EA) reduction unit. Using this analytical protocol, δ2HVSMOW-SLAP values of the non-exchangeable fractions of USGS42 and USGS43 human-hair isotopic reference materials were determined to be –78.5 ± 2.3 ‰ and –50.3 ± 2.8 ‰, respectively. The measured x(H)ex values of keratin materials analyzed with steam equilibration and N2 drying were substantially higher than those previously published, and dry N2 purging was unable to remove absorbed moisture completely, even with overnight purging. The δ2H values of keratin materials measured with steam equilibration were about 10 ‰ lower than values determined with equilibration in desiccators at ambient temperatures when on-line evacuation was used to dry samples. With steam equilibrations the x(H)ex of commercial keratin powder was as high as 28 %. Using human-hair isotopic reference materials to calibrate other keratin materials, such as hoof or horn, can introduce bias in δ2H measurements because the amount of absorbed water and the x(H)ex values may differ from those of unknown samples. Correct δ2HVSMOW-SLAP values of the non-exchangeable fractions of unknown human-hair samples can be determined with atmospheric moisture

  20. Comparison of sediment pollution in the rivers of the Hungarian Upper Tisza Region using non-destructive analytical techniques

    International Nuclear Information System (INIS)

    Osan, Janos; Toeroek, Szabina; Alfoeldy, Balint; Alsecz, Anita; Falkenberg, Gerald; Baik, Soo Yeun; Van Grieken, Rene

    2007-01-01

    The rivers in the Hungarian Upper Tisza Region are frequently polluted mainly due to mining activities in the catchment area. At the beginning of 2000, two major mining accidents occurred in the Romanian part of the catchment area due to the failure of a tailings dam releasing huge amounts of cyanide and heavy metals to the rivers. Surface sediment as well as water samples were collected at six sites in the years 2000-2003, from the northeast-Hungarian section of the Tisza, Szamos and Tur rivers. The sediment pollution of the rivers was compared based on measurements of bulk material and selected single particles, in order to relate the observed compositions and chemical states of metals to the possible sources and weathering of pollution. Non-destructive X-ray analytical methods were applied in order to obtain different kinds of information from the same samples or particles. In order to identify the pollution sources, their magnitude and fate, complementary analyses were carried out. Heterogeneous particulate samples were analyzed from a large geographical territory and a 4-year time period. Individual particles were analyzed only from the 'hot' samples that showed elevated concentrations of heavy metals. Particles that were classified as anthropogenic were finally analyzed to identify trace concentrations and chemical states of heavy metals. Although the Tisza river was affected by water pollution due to the two major mining accidents at the beginning of 2000, the concentration of heavy metals in sediments decreased to the mineral background level 1 year after the pollution event. In the tributaries Szamos and Tur, however, no significant decrease of the heavy metal concentrations was observed in the recent years, indicating a continuous pollution. Among the water suspended particles collected from river Tur, fibers of unknown origin were observed by electron microscopy; these particles were aluminosilicates enriched in Zn and Mn. Cd was also concentrated in

  1. A Simple low-cost device enables four epi-illumination techniques on standard light microscopes.

    Science.gov (United States)

    Ishmukhametov, Robert R; Russell, Aidan N; Wheeler, Richard J; Nord, Ashley L; Berry, Richard M

    2016-02-08

    Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.

  2. Standardization of the radioimmunoassay technique for the determination of human gastrin and its clinical application

    International Nuclear Information System (INIS)

    Peig Ginabredra, M.G.

    1989-01-01

    It was developed and standardized a system of radioimmunoassay for the determination of gastrin, employing synthetic human gastrin for radioiodination and preparation of standard as well as specific antibody raised rabbits. The hormone was labeled with 125 I by the Cloramine T techique and purified by anion exchange chromatography in QAE-Sephadex A-25, being determined its specific activity. The tracer thus obtained was submitted to analysis of purity by poliacrilamide gel eletrophoresis and precipitation of proteins by trichloroacetic acid. Its stability evaluated according to the time of storage, being its purity and adequation for the use in radioimmunoassay also compared to a tracer obtained from a commercial diagnosis kit. The assays were performed by incubation of radioiodinated gastrin, standard gastrin prepared in plasma free from this hormone (from zero to 500 pmol/l) or samples to be assayed with the antiserum for 4 days at 4 0 C. The separation between the free gastrin and the gastrin bound to the antibody was carried out by adsorption of the free hormone to the charcoal, whose ideal concentration was previously determined. Plasma free from gastrin was obtained from time-expired blood bank plasma submitted to extraction with charcoal. When performed the quality control, this radioimmunoassay was shown specific, accurate, precise and sensitive, allowing the performance of valid assays. Its validation was even confirmed by clear discrimination not only of the gastrin concentration in subjects with very low levels (gastrectomized) and extremely high levels (Zollinger-Ellison syndrome) as well as gastrin concentrations in subjects with other diseases, such as Chagas disease, pernicious anemia and chronic renal failure. (author) [pt

  3. Characterization of the neutron sources storage pool of the Neutron Standards Laboratory, using Montecarlo Techniques

    International Nuclear Information System (INIS)

    Campo Blanco, X.

    2015-01-01

    The development of irradiation damage resistant materials is one of the most important open fields in the design of experimental facilities and conceptual nucleoelectric fusion plants. The Neutron Standards Laboratory aims to contribute to this development by allowing the neutron irradiation of materials in its calibration neutron sources storage pool. For this purposes, it is essential to characterize the pool itself in terms of neutron fluence and spectra due to the calibration neutron sources. In this work, the main features of this facility are presented and the characterization of the storage pool is carried out. Finally, an application is shown of the obtained results to the neutron irradiation of material.

  4. Accelerator-based analytical technique in the study of some anti-diabetic medicinal plants of Nigeria

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Omobuwajo, O.R.; Ceccato, D.; Adebajo, A.C.; Buoso, M.C.; Moschini, G.

    2008-01-01

    Diabetes mellitus, a clinical syndrome characterized by hyperglycemia due to deficiency of insulin, is a disease involving the endocrine pancreas and causes considerable morbidity and mortality in the world. In Nigeria, many plants, especially those implicated in herbal recipes for the treatment of diabetes, have not been screened for their elemental constituents while information on phytochemistry of some of them is not available. There is therefore the need to document these constituents as some of these plants are becoming increasingly important as herbal drugs or food additives. The accelerator-based technique PIXE, using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro (Padova) Italy, was employed in the determination of the elemental constituents of these anti-diabetic medicinal plants. Leaves of Gardenia ternifolia, Caesalpina pulcherrima, Solemostenon monostachys, whole plant of Momordica charantia and leaf and stem bark of Hunteria umbellata could be taken as vegetables, neutraceuticals, food additives and supplements in the management of diabetes. However, Hexabolus monopetalus root should be used under prescription

  5. Accelerator-based analytical technique in the study of some anti-diabetic medicinal plants of Nigeria

    Science.gov (United States)

    Olabanji, S. O.; Omobuwajo, O. R.; Ceccato, D.; Adebajo, A. C.; Buoso, M. C.; Moschini, G.

    2008-05-01

    Diabetes mellitus, a clinical syndrome characterized by hyperglycemia due to deficiency of insulin, is a disease involving the endocrine pancreas and causes considerable morbidity and mortality in the world. In Nigeria, many plants, especially those implicated in herbal recipes for the treatment of diabetes, have not been screened for their elemental constituents while information on phytochemistry of some of them is not available. There is therefore the need to document these constituents as some of these plants are becoming increasingly important as herbal drugs or food additives. The accelerator-based technique PIXE, using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro (Padova) Italy, was employed in the determination of the elemental constituents of these anti-diabetic medicinal plants. Leaves of Gardenia ternifolia, Caesalpina pulcherrima, Solemostenon monostachys, whole plant of Momordica charantia and leaf and stem bark of Hunteria umbellata could be taken as vegetables, neutraceuticals, food additives and supplements in the management of diabetes. However, Hexabolus monopetalus root should be used under prescription.

  6. Application of Nuclear Analytical Techniques in Elemental Characterization of Wadi El-Nakhil Alabaster, Central Eastern Desert, Egypt

    Directory of Open Access Journals (Sweden)

    Zain M. Alamoudi

    2016-01-01

    Full Text Available Instrumental neutron activation analysis (INAA is a powerful technique for trace element determination in rocks. Nine alabaster samples were collected from Wadi El-Nakhil located at the intersection of lat. 26°10′50′′N and long. 34°03′40′′E, central Eastern Desert, Egypt, for investigation by INAA and Energy Depressive X-Ray Fluorescence (EDXRF. The samples were irradiated by thermal neutrons at the TRIGA Mainz research reactor at a neutron flux of 7 × 1011 n/cm2·s. Twenty-two elements were determined, namely, As, Ba, Ca, Co, Cr, Sc, Fe, Hf, K, Mg, Mn, Na, Rb, U, Zn, Zr, Lu, Ce, Sm, La, Yb, and Eu. The chemical analysis of alabaster indicated having high contents of CaO and MgO and LOI and low contents of SiO2, Al2O3, Na2O, K2O, MnO, and Fe2O3.

  7. Accelerator-based analytical technique in the study of some anti-diabetic medicinal plants of Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Legnaro, Padova (Italy)], E-mail: skayode2002@yahoo.co.uk; Omobuwajo, O.R. [Department of Pharmacognosy, Obafemi Awolowo University, Ile-Ife (Nigeria); Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Legnaro, Padova (Italy); Dipartmento di Fisica, Universita di Padova, Padova (Italy); Adebajo, A.C. [Department of Pharmacognosy, Obafemi Awolowo University, Ile-Ife (Nigeria); Buoso, M.C. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Legnaro, Padova (Italy); Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL), I-35020 Legnaro, Padova (Italy); Dipartmento di Fisica, Universita di Padova, Padova (Italy)

    2008-05-15

    Diabetes mellitus, a clinical syndrome characterized by hyperglycemia due to deficiency of insulin, is a disease involving the endocrine pancreas and causes considerable morbidity and mortality in the world. In Nigeria, many plants, especially those implicated in herbal recipes for the treatment of diabetes, have not been screened for their elemental constituents while information on phytochemistry of some of them is not available. There is therefore the need to document these constituents as some of these plants are becoming increasingly important as herbal drugs or food additives. The accelerator-based technique PIXE, using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro (Padova) Italy, was employed in the determination of the elemental constituents of these anti-diabetic medicinal plants. Leaves of Gardenia ternifolia, Caesalpina pulcherrima, Solemostenon monostachys, whole plant of Momordica charantia and leaf and stem bark of Hunteria umbellata could be taken as vegetables, neutraceuticals, food additives and supplements in the management of diabetes. However, Hexabolus monopetalus root should be used under prescription.

  8. Neutron flux characterization of californium-252 Neutron Research Facility at the University of Texas - Pan American by nuclear analytical technique

    Science.gov (United States)

    Wahid, Kareem; Sanchez, Patrick; Hannan, Mohammad

    2014-03-01

    In the field of nuclear science, neutron flux is an intrinsic property of nuclear reaction facilities that is the basis for experimental irradiation calculations and analysis. In the Rio Grande Valley (Texas), the UTPA Neutron Research Facility (NRF) is currently the only neutron facility available for experimental research purposes. The facility is comprised of a 20-microgram californium-252 neutron source surrounded by a shielding cascade containing different irradiation cavities. Thermal and fast neutron flux values for the UTPA NRF have yet to be fully investigated and may be of particular interest to biomedical studies in low neutron dose applications. Though a variety of techniques exist for the characterization of neutron flux, neutron activation analysis (NAA) of metal and nonmetal foils is a commonly utilized experimental method because of its detection sensitivity and availability. The aim of our current investigation is to employ foil activation in the determination of neutron flux values for the UTPA NSRF for further research purposes. Neutron spectrum unfolding of the acquired experimental data via specialized software and subsequent comparison for consistency with computational models lends confidence to the results.

  9. CB4-03: An Eye on the Future: A Review of Data Virtualization Techniques to Improve Research Analytics

    Science.gov (United States)

    Richter, Jack; McFarland, Lela; Bredfeldt, Christine

    2012-01-01

    and drawbacks of these techniques.

  10. Some examples of the application of an analytical technique to ion-optical calculations for a new injector of the Lund Pelletron accelerator

    International Nuclear Information System (INIS)

    Hellborg, R.; Faarinen, M.; Magnusson, C.-E.; Bazhal, S.V.; Romanov, V.A.

    2001-01-01

    The 3UDH Pelletron tandem accelerator in Lund is being developed to be more suitable for accelerator mass spectrometry of heavy ions. This development includes the installation of an electrostatic and a magnetic analyzer in a new injector aimed to obtain better mass and energy separation. In the present paper some applications of the first-order analytical calculation technique, used at the design stage of the new injector, are discussed. The estimation of the maximum possible opening of the analyzer slits was carried out, followed by the calculation of the analyzer acceptances. The values of the acceptances for the two transversal planes, as well as their contours are given. Some results of more detailed numerical calculation of the ion beam transport through the analyzers are reported

  11. Evaluation of Visualization Using a 50/50 (Contrast Media/Glucose 5% Solution) Technique for Radioembolization as an Alternative to a Standard Sandwich Technique.

    Science.gov (United States)

    Paprottka, Karolin J; Todica, Andrei; Ilhan, Harun; Rübenthaler, Johannes; Schoeppe, Franziska; Michl, Marlies; Heinemann, Volker; Bartenstein, Peter; Reiser, Maximilian F; Paprottka, Philipp M

    2017-11-01

    Radioembolization (RE) with 90 yttrium ( 90 Y) resin microspheres generally employs a sandwich technique with separate sequential administration of contrast medium (CM), followed by vehicle (e.g., glucose 5% [G5] solution), then 90 Y resin microspheres (in G5), then G5, and then CM again to avoid contact of CM and microspheres under fluoroscopic guidance. This study evaluates the visualization quality and safety of a modified sandwich technique with a 50/50-mixture of CM (Imeron 300) and G5 for administration of 90 Y resin microspheres. A retrospective analysis of 81 RE procedures in patients with primary or secondary liver tumors was performed. The quality of angiographic visualization of the hepatic vessels was assessed before the first injection and immediately before the whole dose has been injected. Visualization and flow rate were graded on a 5-point scale: 1 = very good to 5 = not visible/no antegrade flow. Univariate logistic regression models and multiple linear regression models were used to evaluate the prognostic variables associated with visualization and flow scores. Visualization quality was inversely related to flow rate, the lower the flow rate the better the grade of the visualization. Visualization quality was also inversely related to body-mass-index (BMI). Performing RE with the 50/50-CM/G5 mixture resulted in a mean injection time for 1 GBq of 15 min. No clinically significant adverse events, including radiation-induced liver disease were reported. RE with a 50/50-mixture of CM and G5 for administration of 90 Y resin microspheres in a modified sandwich technique is a safe administration alternative and provides good visualization of hepatic vessels, which is inversely dependent on flow rate and BMI. Injection time was reduced compared with our experience with the standard sandwich technique.

  12. Robot-assisted repair of tricuspid leaflet prolapse using standard valvuloplasty techniques.

    Science.gov (United States)

    Seder, Christopher W; Suri, Rakesh M; Rehfeldt, Kent; Pislaru, Sorin; Burkhart, Harold M

    2012-11-01

    While minimally invasive approaches are used routinely to correct severe mitral regurgitation due to leaflet prolapse, isolated tricuspid valve prolapse is less frequent and usually addressed via sternotomy. A 34-year-old female presented with exertional dyspnea and severe tricuspid regurgitation due to an unsupported anterior leaflet causing prolapse, a tethered septal leaflet, and dilated annulus. Herein, the technique is described of a robot-assisted tricuspid valve repair using established open valvuloplasty principles. The robotic repair was performed by the placement of Gore-Tex neochordae from the anterior papillary muscle to the anterior tricuspid leaflet, plication of the anteroseptal and anteroposterior commissures, closure of an anterior leaflet cleft, and the insertion of an annuloplasty band. The patient had an uncomplicated hospital course and was dismissed home on the third postoperative day.

  13. Standard practice for evaluation of hydrogen uptake, permeation, and transport in metals by an electrochemical technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This practice gives a procedure for the evaluation of hydrogen uptake, permeation, and transport in metals using an electrochemical technique which was developed by Devanathan and Stachurski. While this practice is primarily intended for laboratory use, such measurements have been conducted in field or plant applications. Therefore, with proper adaptations, this practice can also be applied to such situations. 1.2 This practice describes calculation of an effective diffusivity of hydrogen atoms in a metal and for distinguishing reversible and irreversible trapping. 1.3 This practice specifies the method for evaluating hydrogen uptake in metals based on the steady-state hydrogen flux. 1.4 This practice gives guidance on preparation of specimens, control and monitoring of the environmental variables, test procedures, and possible analyses of results. 1.5 This practice can be applied in principle to all metals and alloys which have a high solubility for hydrogen, and for which the hydrogen permeation is ...

  14. Pyrite: A blender plugin for visualizing molecular dynamics simulations using industry-standard rendering techniques.

    Science.gov (United States)

    Rajendiran, Nivedita; Durrant, Jacob D

    2018-05-05

    Molecular dynamics (MD) simulations provide critical insights into many biological mechanisms. Programs such as VMD, Chimera, and PyMOL can produce impressive simulation visualizations, but they lack many advanced rendering algorithms common in the film and video-game industries. In contrast, the modeling program Blender includes such algorithms but cannot import MD-simulation data. MD trajectories often require many gigabytes of memory/disk space, complicating Blender import. We present Pyrite, a Blender plugin that overcomes these limitations. Pyrite allows researchers to visualize MD simulations within Blender, with full access to Blender's cutting-edge rendering techniques. We expect Pyrite-generated images to appeal to students and non-specialists alike. A copy of the plugin is available at http://durrantlab.com/pyrite/, released under the terms of the GNU General Public License Version 3. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Experimental approaches and analytical technique for determining heavy metals in fallen dust at ferrosilicon production factory in Edfu, Aswan, Egypt

    Science.gov (United States)

    Soltan, M.E.; Rageh, H.M.; Rageh, N.M.; Ahmed, M.E.

    2005-01-01

    In this study aimed to evaluate the pollution extent of metals and nonmetals inside and outside the ferrosilicon production factory in Edfu, Aswan, Egypt, raw materials (quartz, cokes, iron oxides), ferrosilicon alloy, silica fume, dust and suspended dust (at different sites) samples were collected from the factory, and fallen dust samples were collected from outside the factory, horizontally (at different sites and different distance and directions) and vertically (at different floors in the selected buildings). Gravimetric methods, X-ray fluorescence (XRF), flame photometer, wide range carbon determinator and atomic absorption spectroscopy tools were used for elements determination. The results indicating that the fallen dust and its element contents on southern factory walls being higher than those on eastern factory walls may be due to the nature of the dusts and effects of wind force and wind direction. Fallen dust levels in different regions outside the factory were found to be affected by the distance, direction and floors. The nature of dust samples was affected by gravity and the suspended dust in different factory units depended on the work capacity and method of handling materials by personnel in different production units. Silica fume was a complicated problem, had dangerous effect against the workers’ health, and was characterized by high concentrations of SiO2 (90.6%~93.6%) and heavy metals (Mn, 420.6×10−6~520.3×10−6; Fe, 2354×10−6~2685×10−6; Co, 80.7×10−6~101.6×10−6 and Ni, 5.3×10−6~6.05×10−6). The TSP (Total Suspended Particulate) levels in all factory units were higher than the recommended air quality value (70 μg/m3) under Egyptian law. The effect of ferrosilicon factory fallen dust on the surrounding regions decreased with increasing distance between the factory and these regions. The suspended dust samples in the factory units and their components greatly exceeded national and international standards, so health and

  16. Psychovisual masks and intelligent streaming RTP techniques for the MPEG-4 standard

    Science.gov (United States)

    Mecocci, Alessandro; Falconi, Francesco

    2003-06-01

    In today multimedia audio-video communication systems, data compression plays a fundamental role by reducing the bandwidth waste and the costs of the infrastructures and equipments. Among the different compression standards, the MPEG-4 is becoming more and more accepted and widespread. Even if one of the fundamental aspects of this standard is the possibility of separately coding video objects (i.e. to separate moving objects from the background and adapt the coding strategy to the video content), currently implemented codecs work only at the full-frame level. In this way, many advantages of the flexible MPEG-4 syntax are missed. This lack is due both to the difficulties in properly segmenting moving objects in real scenes (featuring an arbitrary motion of the objects and of the acquisition sensor), and to the current use of these codecs, that are mainly oriented towards the market of DVD backups (a full-frame approach is enough for these applications). In this paper we propose a codec for MPEG-4 real-time object streaming, that codes separately the moving objects and the scene background. The proposed codec is capable of adapting its strategy during the transmission, by analysing the video currently transmitted and setting the coder parameters and modalities accordingly. For example, the background can be transmitted as a whole or by dividing it into "slightly-detailed" and "highly detailed" zones that are coded in different ways to reduce the bit-rate while preserving the perceived quality. The coder can automatically switch in real-time, from one modality to the other during the transmission, depending on the current video content. Psychovisual masks and other video-content based measurements have been used as inputs for a Self Learning Intelligent Controller (SLIC) that changes the parameters and the transmission modalities. The current implementation is based on the ISO 14496 standard code that allows Video Objects (VO) transmission (other Open Source Codes

  17. Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover determination of the total normal emittance (Note) of surfaces by means of portable, inspection-meter instruments. Note 1—Total normal emittance (εN) is defined as the ratio of the normal radiance of a specimen to that of a blackbody radiator at the same temperature. The equation relating εN to wavelength and spectral normal emittance [εN (λ)] is where: L b(λ, T) = Planck's blackbody radiation function = c1π −1λ−5(ec2/λT − 1)−1, c1 = 3.7415 × 10−16 W·m 2, c2 = 1.4388 × 10−2 m·K, T = absolute temperature, K, λ = wavelength, m, Lb(λ, T)dλ = Δπ −1T4, and Δ = Stefan-Boltzmann constant = 5.66961 × 10 −8 W·m2·K−4 1.2 These test methods are intended for measurements on large surfaces when rapid measurements must be made and where a nondestructive test is desired. They are particularly useful for production control tests. 1.3 The values stated in SI units are to be regarded as standard. No other units of measu...

  18. Watermarking Techniques Using Least Significant Bit Algorithm for Digital Image Security Standard Solution- Based Android

    Directory of Open Access Journals (Sweden)

    Ari Muzakir

    2017-05-01

    Full Text Available Ease of deployment of digital image through the internet has positive and negative sides, especially for owners of the original digital image. The positive side of the ease of rapid deployment is the owner of that image deploys digital image files to various sites in the world address. While the downside is that if there is no copyright that serves as protector of the image it will be very easily recognized ownership by other parties. Watermarking is one solution to protect the copyright and know the results of the digital image. With Digital Image Watermarking, copyright resulting digital image will be protected through the insertion of additional information such as owner information and the authenticity of the digital image. The least significant bit (LSB is one of the algorithm is simple and easy to understand. The results of the simulations carried out using android smartphone shows that the LSB watermarking technique is not able to be seen by naked human eye, meaning there is no significant difference in the image of the original files with images that have been inserted watermarking. The resulting image has dimensions of 640x480 with a bit depth of 32 bits. In addition, to determine the function of the ability of the device (smartphone in processing the image using this application used black box testing. 

  19. Characterization of the storage pool of the Neutron Standards Laboratory of CIEMAT, using Monte Carlo techniques

    Energy Technology Data Exchange (ETDEWEB)

    Campo B, X.; Mendez V, R.; Embid S, M. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Av. Complutense 40, 28040 Madrid (Spain); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas (Mexico); Sanz G, J., E-mail: xandra.campo@ciemat.es [Universidad Nacional de Educacion a Distancia, Escuela Tecnica Superior de Ingenieros Industriales, C. Juan del Rosal 12, 28040 Madrid (Spain)

    2014-08-15

    Neutron Standards Laboratory of CIEMAT in Spain is a brand new irradiation facility, with {sup 241}Am-Be (185 GBq) and {sup 252}Cf (5 GBq) calibrated neutron sources which are stored in a water pool with a concrete cover. From this storage place an automated system is able to take the selected source and place it in the irradiation position, 4 m over the ground level and in the geometrical center of the Irradiation Room with 9 m (length) x 7.5 m (width) x 8 m (height). For calibration or irradiation purposes, detectors or materials can be placed on a bench but it is possible to use the pool (1.0 m x 1.5 m and more than 1.0 m depth) for long time irradiations in thermal neutron fields. For this reason it is essential to characterize the pool itself in terms of neutron spectrum. In this document, the main features of this facility are presented and the characterization of the storage pool in terms of neutron fluence rate and neutron spectrum has been carried out using simulations with MCNPX-2.7.e code. The MCNPX-2.7.e model has been validated using experimental measurements outside the pool (Bert hold LB6411). Inside the pool, the fluence rate decreases and the spectra is thermalized with the distance to the {sup 252}Cf source. This source predominates and the effect of the {sup 241}Am-Be source in these magnitudes is not shown until positions closer than 20 cm from it. (author)

  20. Characterization of the storage pool of the Neutron Standards Laboratory of CIEMAT, using Monte Carlo techniques

    International Nuclear Information System (INIS)

    Campo B, X.; Mendez V, R.; Embid S, M.; Vega C, H. R.; Sanz G, J.

    2014-08-01

    Neutron Standards Laboratory of CIEMAT in Spain is a brand new irradiation facility, with 241 Am-Be (185 GBq) and 252 Cf (5 GBq) calibrated neutron sources which are stored in a water pool with a concrete cover. From this storage place an automated system is able to take the selected source and place it in the irradiation position, 4 m over the ground level and in the geometrical center of the Irradiation Room with 9 m (length) x 7.5 m (width) x 8 m (height). For calibration or irradiation purposes, detectors or materials can be placed on a bench but it is possible to use the pool (1.0 m x 1.5 m and more than 1.0 m depth) for long time irradiations in thermal neutron fields. For this reason it is essential to characterize the pool itself in terms of neutron spectrum. In this document, the main features of this facility are presented and the characterization of the storage pool in terms of neutron fluence rate and neutron spectrum has been carried out using simulations with MCNPX-2.7.e code. The MCNPX-2.7.e model has been validated using experimental measurements outside the pool (Bert hold LB6411). Inside the pool, the fluence rate decreases and the spectra is thermalized with the distance to the 252 Cf source. This source predominates and the effect of the 241 Am-Be source in these magnitudes is not shown until positions closer than 20 cm from it. (author)

  1. Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?

    Science.gov (United States)

    Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique

    2014-10-07

    Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young's modulus over the range of normal and cirrhotic liver stiffnesses. The Young's modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.

  2. Standardization of the Fricke gel dosimetry method and tridimensional dose evaluation using the magnetic resonance imaging technique

    International Nuclear Information System (INIS)

    Cavinato, Christianne Cobello

    2009-01-01

    This study standardized the method for obtaining the Fricke gel solution developed at IPEN. The results for different gel qualities used in the preparation of solutions and the influence of the gelatin concentration in the response of dosimetric solutions were compared. Type tests such as: dose response dependence, minimum and maximum detection limits, response reproducibility, among others, were carried out using different radiation types and the Optical Absorption (OA) spectrophotometry and Magnetic Resonance (MR) techniques. The useful dose ranges for Co 60 gamma radiation and 6 MeV photons are 0,4 to 30,0 Gy and 0,5 to 100,0 Gy , using OA and MR techniques, respectively. A study of ferric ions diffusion in solution was performed to determine the optimum time interval between irradiation and samples evaluation; until 2,5 hours after irradiation to obtain sharp MR images. A spherical simulator consisting of Fricke gel solution prepared with 5% by weight 270 Bloom gelatine (national quality) was developed to be used to three-dimensional dose assessment using the Magnetic Resonance Imaging (MRI) technique. The Fricke gel solution prepared with 270 Bloom gelatine, that, in addition to low cost, can be easily acquired on the national market, presents satisfactory results on the ease of handling, sensitivity, response reproducibility and consistency. The results confirm their applicability in the three-dimensional dosimetry using MRI technique. (author)

  3. The 'Pull' Technique for Removal of Peritoneal Dialysis Catheters: A Call for Re-Evaluation of Practice Standards.

    Science.gov (United States)

    Grieff, Marvin; Mamo, Elizabeth; Scroggins, Gina; Kurchin, Alexander

    2017-01-01

    ♦ BACKGROUND: The most commonly used peritoneal dialysis (PD) catheters have silicon tubing with attached Dacron cuffs. The current standard of care for PD catheter removal is by complete surgical dissection, withdrawing both the tubing and the cuffs. The intention is to avoid infection of any residual part of the catheter. We retrospectively analyzed our results with the alternative 'pull' technique, by which the silicon tube is pulled out, leaving the Dacron cuffs within the abdominal wall. This technique never gained popularity due to concern that the retained cuffs would get infected. ♦ METHODS: We reviewed our experience from an 18-month period, between January 2014 and June 2015. There were 46 catheter removals in 40 patients. All the catheters were of the double-cuffed coiled Tenckhoff type (Covidien, Dublin, Ireland). ♦ RESULTS: Of the 46 catheter removals by the 'pull' technique, there was only 1 case of retained cuff infection. ♦ CONCLUSIONS: The 'pull' technique is a safe method for Tenckhoff catheter removal with low risk of infection. We strongly recommend it as the procedure of choice. Copyright © 2017 International Society for Peritoneal Dialysis.

  4. [The standard implantation of a total hip prosthesis via two incisions (the Yale Technique)].

    Science.gov (United States)

    Kipping, Robert

    2009-09-01

    Implantation of a total hip endoprosthesis with minimal trauma to the soft tissue. The need for visual aids (e.g., navigation or X-rays) during the procedure is frequently avoided. All kinds of coxarthrosis for every age group, for every variation of bone construction, and even in obese patients. Extremely dysplastic hip joints involving the development of a secondary socket and the necessity of reconstruction of the acetabular socket (e.g., in the Harris method). Using a fixed lateral position, a small entry incision is made between the tensor fasciae latae and the sartorius muscles and the prosthesis socket is put into place. Via a second dorsal incision, after stripping the exterior rotators, the prosthesis stem and ball are implanted and the two parts of the prosthesis are attached. Full weight bearing allowed immediately. A luxation prophylaxis, in the form of a self-developed hip bodice (the so-called Yale bandage), is used until the end of the 4th postoperative week. Discharge from hospital is possible after just a few days. Upon discharge, the patient is sent to a rehabilitation facility, either as a resident or as an outpatient, for approximately 3 weeks. Return to the workplace, with only light physical activity, is possible once the wound has healed completely; this could be as soon as 14 days after the operation. Checkups are made after 4 weeks, 6 months, 1 year and then every year; these checkups include a full examination, X-rays and laboratory tests. Full exposure to sport or heavy manual labor is usually approved after the 6-month checkup. Between October 2004 and April 2006, a total of 221 patients underwent surgery using this new technique (of these 15 patients underwent two-stage bilateral hip joint replacements). Patients were followed up for a minimum of 12 months and a maximum of 30 months. The Harris Hip Score improved from an average of 45.25 preoperatively to 96.4 postoperatively.

  5. Unilateral NMR, 13C CPMAS NMR spectroscopy and micro-analytical techniques for studying the materials and state of conservation of an ancient Egyptian wooden sarcophagus.

    Science.gov (United States)

    Proietti, Noemi; Presciutti, Federica; Di Tullio, Valeria; Doherty, Brenda; Marinelli, Anna Maria; Provinciali, Barbara; Macchioni, Nicola; Capitani, Donatella; Miliani, Costanza

    2011-03-01

    A multi-technique approach was employed to study a decorated Egyptian wooden sarcophagus (XXV-XXVI dynasty, Third Intermediate Period), belonging to the Museo del Vicino Oriente of the Sapienza University of Rome. Portable non-invasive unilateral NMR was applied to evaluate the conservation state of the sarcophagus. Moreover, using unilateral NMR, a non-invasive analytical protocol was established to detect the presence of organic substances on the surface and/or embedded in the wooden matrix. This protocol allowed for an educated sampling campaign aimed at further investigating the state of degradation of the wood and the presence of organic substances by (13)C cross polarization magic angle spinning (CPMAS) NMR spectroscopy. The composition of the painted layer was analysed by optical microscopy (OM), scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS), Raman and surface enhanced (resonance) Raman spectroscopy (SERS/SERRS), infrared and GC-MS techniques, evidencing original components such as clay minerals, Egyptian green, indigo, natural gums, and also highlighting restoration pigments and alteration compounds. The identification of the wood, of great value for the reconstruction of the history of the artwork, was achieved by means of optical microscopy.

  6. The application of nuclear analytical techniques in the study of elements distribution pattern associated with Gubrunde Uranium occurrence in North-Eastern Nigeria

    International Nuclear Information System (INIS)

    Ige, T. A.

    1994-01-01

    Prospecting for high grade uranium deposits in North-East Nigeria has, over the years, amongst other reasons, been handicapped by lack of adequate understanding of the elemental primary and secondary dispersion patterns associated with known occurrences in the region. One hundred and forty-four samples from low grade Uranium occurrences at Gubrunde horst consisting of disseminated ores and host rocks, bark and soil samples were therefore, analysed for forty-four elements using Neutron Activation Analysis (with Gamma Spectrometry - INAA and Delayed Neutron Counting - DNC) and Energy Dispersive X-ray Fluorescence Techniques. The analytical data have been evaluated using multivariate statistical techniques. The results show some major element groupings (association). The first group consists of Ph, Ba, Ce and Sm (LREE) that are enriched with increasing uranium concentration in the mineralized zone and are therefore, capable of serving as path-finder elements for uranium. The second group comprising of K 2 O, CaO, Na 2 O and the HREE are depleted in the mineralized zones due to the action of hydrothermal fluids and are indicative of altered/mineralized rocks. The third group consists of the other elements which feature little or no significant enrichment with uranium but may be associated with ferruginisation (hematite) and possibly refractory minerals. It is found that iron does not correlate well with uranium in this report which may indicate ferruginization and mineralization as two independent processes

  7. Radar chart array analysis to visualize effects of formulation variables on IgG1 particle formation as measured by multiple analytical techniques.

    Science.gov (United States)

    Kalonia, Cavan; Kumru, Ozan S; Kim, Jae Hyun; Middaugh, C Russell; Volkin, David B

    2013-12-01

    This study presents a novel method to visualize protein aggregate and particle formation data to rapidly evaluate the effect of solution and stress conditions on the physical stability of an immunoglobulin G (IgG) 1 monoclonal antibody (mAb). Radar chart arrays were designed so that hundreds of microflow digital imaging (MFI) solution measurements, evaluating different mAb formulations under varying stresses, could be presented in a single figure with minimal loss of data resolution. These MFI radar charts show measured changes in subvisible particle number, size, and morphology distribution as a change in the shape of polygons. Radar charts were also created to visualize mAb aggregate and particle formation across a wide size range by combining data sets from size-exclusion chromatography, Archimedes resonant mass measurements, and MFI. We found that the environmental/mechanical stress condition (e.g., heat vs. agitation) was the most important factor in influencing the particle size and morphology distribution with this IgG1 mAb. Additionally, the presence of NaCl exhibited a pH and stress-dependent behavior resulting in promotion or inhibition mAb particle formation. This data visualization technique provides a comprehensive analysis of the aggregation tendencies of this IgG1 mAb in different formulations with varying stresses as measured by different analytical techniques. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

  8. Application of radar chart array analysis to visualize effects of formulation variables on IgG1 particle formation as measured by multiple analytical techniques

    Science.gov (United States)

    Kalonia, Cavan; Kumru, Ozan S.; Kim, Jae Hyun; Middaugh, C. Russell; Volkin, David B.

    2013-01-01

    This study presents a novel method to visualize protein aggregate and particle formation data to rapidly evaluate the effect of solution and stress conditions on the physical stability of an IgG1 monoclonal antibody (mAb). Radar chart arrays were designed so that hundreds of Microflow Digital Imaging (MFI) solution measurements, evaluating different mAb formulations under varying stresses, could be presented in a single figure with minimal loss of data resolution. These MFI radar charts show measured changes in subvisible particle number, size and morphology distribution as a change in the shape of polygons. Radar charts were also created to visualize mAb aggregate and particle formation across a wide size range by combining data sets from size exclusion chromatography (SEC), Archimedes resonant mass measurements, and MFI. We found that the environmental/mechanical stress condition (e.g., heat vs. agitation) was the most important factor in influencing the particle size and morphology distribution with this IgG1 mAb. Additionally, the presence of NaCl exhibited a pH and stress dependent behavior resulting in promotion or inhibition mAb particle formation. This data visualization technique provides a comprehensive analysis of the aggregation tendencies of this IgG1 mAb in different formulations with varying stresses as measured by different analytical techniques. PMID:24122556

  9. Determination and Standardization of Analytical Conditions for Dissolved Boron in Coastal Waters of East Sea in Korea by ICP-OES

    Science.gov (United States)

    Yoon, H.; Shin, M.; Yoon, C.; Lee, J.

    2005-12-01

    The analysis of metals in seawaters has been an important subject for many years. Achieving low-level detection limits as well as overcoming high matrix effect are requested in seawater analysis especially elements of interest are present in various chemical forms. Among them, boron is one of the widely distributed elements in nature and its concentrations of about 10 ppm in the Earth's crust and about 4.5 ppm in the seawater as borates. In seawater boron concentration exhibit a linear relationship to the amount of chloride ion present. Boron had been considered as one of the valuable elements to recover from seawaters for commercial use. Currently, we launched research team for the production of valuable metals from seawaters in Korea that can be used commercially. Several metals including boron were already under serious studies. In this study we aim to prepare standardized operational procedures in analysis of boron during pilot study for boron recovery as pilot recovery process. Inductively coupled plasma Optical Emission Spectrometry (ICP-OES) method is preferred for the analysis of the low levels of boron found in environmental samples such as seawater. In order to develop test method for the determination of dissolved Boron from East Sea Seawater in Korea, all soluble boron present in seawater has been tested and accuracy of measurement was checked from the sampling step. The result of analysis of boron in seawaters presents many difficult problems, ionization of from the alkali and alkaline earth metals. And the problems also exist in handling nebulizer and injector tubes in high saline solutions. The scope of this study was to determine boron which can contain up to 35psu dissolved salt. The work also included comparing various analytical methods for better accurate results in several solution conditions. Dilution, standard addition, matrix matching calibration methods was thoroughly tested differently and detailed operating conditions for using auxiliary

  10. Establishment of a Standard Analytical Model of Distribution Network with Distributed Generators and Development of Multi Evaluation Method for Network Configuration Candidates

    Science.gov (United States)

    Hayashi, Yasuhiro; Kawasaki, Shoji; Matsuki, Junya; Matsuda, Hiroaki; Sakai, Shigekazu; Miyazaki, Teru; Kobayashi, Naoki

    Since a distribution network has many sectionalizing switches, there are huge radial network configuration candidates by states (opened or closed) of sectionalizing switches. Recently, the total number of distributed generation such as photovoltaic generation system and wind turbine generation system connected to the distribution network is drastically increased. The distribution network with the distributed generators must be operated keeping reliability of power supply and power quality. Therefore, the many configurations of the distribution network with the distributed generators must be evaluated multiply from various viewpoints such as distribution loss, total harmonic distortion, voltage imbalance and so on. In this paper, the authors propose a multi evaluation method to evaluate the distribution network configuration candidates satisfied with constraints of voltage and line current limit from three viewpoints ((1) distribution loss, (2) total harmonic distortion and (3) voltage imbalance). After establishing a standard analytical model of three sectionalized and three connected distribution network configuration with distributed generators based on the practical data, the multi evaluation for the established model is carried out by using the proposed method based on EMTP (Electro-Magnetic Transients Programs).

  11. Web Analytics

    Science.gov (United States)

    EPA’s Web Analytics Program collects, analyzes, and provides reports on traffic, quality assurance, and customer satisfaction metrics for EPA’s website. The program uses a variety of analytics tools, including Google Analytics and CrazyEgg.

  12. Russian Language Development Assessment as a Standardized Technique for Assessing Communicative Function in Children Aged 3–9 Years

    Directory of Open Access Journals (Sweden)

    Prikhoda N.A.,

    2016-10-01

    Full Text Available The article describes the Russian Language Development Assessment, a standardized individual diagnostic tool for children aged from 3 to 9 that helps to assess the following components of a child’s communicative function: passive vocabulary, expressive vocabulary, knowledge of semantic constructs with logical, temporal and spatial relations, passive perception and active use of syntactic and morphological features of words in a sentence, active and passive phonological awareness, active and passive knowledge of syntactic structures and categories. The article provides descriptions of content and diagnostic procedures for all 7 subtests included in the assessment (Passive Vocabulary, Active Vocabulary, Linguistic Operators, Sentence structure, Word Structure, Phonology, Sentence Repetition. Basing on the data collected in the study that involved 86 first- graders of a Moscow school, the article analyzes the internal consistency and construct validity of each subtest of the technique. It concludes that the Russian Language Development Assessment technique can be of much use both in terms of diagnostic purposes and in supporting children with ASD taking into account the lack of standardized tools for language and speech development assessment in Russian and the importance of this measure in general.

  13. A comparative study of standard vs. high definition colonoscopy for adenoma and hyperplastic polyp detection with optimized withdrawal technique.

    Science.gov (United States)

    East, J E; Stavrindis, M; Thomas-Gibson, S; Guenther, T; Tekkis, P P; Saunders, B P

    2008-09-15

    Colonoscopy has a known miss rate for polyps and adenomas. High definition (HD) colonoscopes may allow detection of subtle mucosal change, potentially aiding detection of adenomas and hyperplastic polyps. To compare detection rates between HD and standard definition (SD) colonoscopy. Prospective, cohort study with optimized withdrawal technique (withdrawal time >6 min, antispasmodic, position changes, re-examining flexures and folds). One hundred and thirty patients attending for routine colonoscopy were examined with either SD (n = 72) or HD (n = 58) colonoscopes. Groups were well matched. Sixty per cent of patients had at least one adenoma detected with SD vs. 71% with HD, P = 0.20, relative risk (benefit) 1.32 (95% CI 0.85-2.04). Eighty-eight adenomas (mean +/- standard deviation 1.2 +/- 1.4) were detected using SD vs. 93 (1.6 +/- 1.5) with HD, P = 0.12; however more nonflat, diminutive (9 mm) hyperplastic polyps was 7% (0.09 +/- 0.36). High definition did not lead to a significant increase in adenoma or hyperplastic polyp detection, but may help where comprehensive lesion detection is paramount. High detection rates appear possible with either SD or HD, when using an optimized withdrawal technique.

  14. Critical Assessment of Analytical Techniques in the Search for Biomarkers on Mars: A Mummified Microbial Mat from Antarctica as a Best-Case Scenario.

    Science.gov (United States)

    Blanco, Yolanda; Gallardo-Carreño, Ignacio; Ruiz-Bermejo, Marta; Puente-Sánchez, Fernando; Cavalcante-Silva, Erika; Quesada, Antonio; Prieto-Ballesteros, Olga; Parro, Víctor

    2017-10-01

    The search for biomarkers of present or past life is one of the major challenges for in situ planetary exploration. Multiple constraints limit the performance and sensitivity of remote in situ instrumentation. In addition, the structure, chemical, and mineralogical composition of the sample may complicate the analysis and interpretation of the results. The aim of this work is to highlight the main constraints, performance, and complementarity of several techniques that have already been implemented or are planned to be implemented on Mars for detection of organic and molecular biomarkers on a best-case sample scenario. We analyzed a 1000-year-old desiccated and mummified microbial mat from Antarctica by Raman and IR (infrared) spectroscopies (near- and mid-IR), thermogravimetry (TG), differential thermal analysis, mass spectrometry (MS), and immunological detection with a life detector chip. In spite of the high organic content (ca. 20% wt/wt) of the sample, the Raman spectra only showed the characteristic spectral peaks of the remaining beta-carotene biomarker and faint peaks of phyllosilicates over a strong fluorescence background. IR spectra complemented the mineralogical information from Raman spectra and showed the main molecular vibrations of the humic acid functional groups. The TG-MS system showed the release of several volatile compounds attributed to biopolymers. An antibody microarray for detecting cyanobacteria (CYANOCHIP) detected biomarkers from Chroococcales, Nostocales, and Oscillatoriales orders. The results highlight limitations of each technique and suggest the necessity of complementary approaches in the search for biomarkers because some analytical techniques might be impaired by sample composition, presentation, or processing. Key Words: Planetary exploration-Life detection-Microbial mat-Life detector chip-Thermogravimetry-Raman spectroscopy-NIR-DRIFTS. Astrobiology 17, 984-996.

  15. Critical Assessment of Analytical Techniques in the Search for Biomarkers on Mars: A Mummified Microbial Mat from Antarctica as a Best-Case Scenario

    Science.gov (United States)

    Blanco, Yolanda; Gallardo-Carreño, Ignacio; Ruiz-Bermejo, Marta; Puente-Sánchez, Fernando; Cavalcante-Silva, Erika; Quesada, Antonio; Prieto-Ballesteros, Olga; Parro, Víctor

    2017-10-01

    The search for biomarkers of present or past life is one of the major challenges for in situ planetary exploration. Multiple constraints limit the performance and sensitivity of remote in situ instrumentation. In addition, the structure, chemical, and mineralogical composition of the sample may complicate the analysis and interpretation of the results. The aim of this work is to highlight the main constraints, performance, and complementarity of several techniques that have already been implemented or are planned to be implemented on Mars for detection of organic and molecular biomarkers on a best-case sample scenario. We analyzed a 1000-year-old desiccated and mummified microbial mat from Antarctica by Raman and IR (infrared) spectroscopies (near- and mid-IR), thermogravimetry (TG), differential thermal analysis, mass spectrometry (MS), and immunological detection with a life detector chip. In spite of the high organic content (ca. 20% wt/wt) of the sample, the Raman spectra only showed the characteristic spectral peaks of the remaining beta-carotene biomarker and faint peaks of phyllosilicates over a strong fluorescence background. IR spectra complemented the mineralogical information from Raman spectra and showed the main molecular vibrations of the humic acid functional groups. The TG-MS system showed the release of several volatile compounds attributed to biopolymers. An antibody microarray for detecting cyanobacteria (CYANOCHIP) detected biomarkers from Chroococcales, Nostocales, and Oscillatoriales orders. The results highlight limitations of each technique and suggest the necessity of complementary approaches in the search for biomarkers because some analytical techniques might be impaired by sample composition, presentation, or processing.

  16. Non-destructive micro-analytical differentiation of copper pigments in paint layers of works of art using laboratory-based techniques.

    Science.gov (United States)

    Svarcová, Silvie; Cermáková, Zdeňka; Hradilová, Janka; Bezdička, Petr; Hradil, David

    2014-11-11

    An unambiguous identification of pigments in paint layers of works of art forms a substantial part of the description of a painting technique, which is essential for the evaluation of the work of art including determination of the period and/or region of its creation as well as its attribution to a workshop or an author. Copper pigments represent a significant group of materials used in historic paintings. Because of their substantial diversity and, on the other hand, similarity, their identification and differentiation is a challenging task. An analytical procedure for unambiguous determination of both mineral-type (azurite, malachite, posnjakite, atacamite, etc.) and verdigris-type (copper acetates) copper pigments in the paint layers is presented, including light microscopy under VIS and UV light, electron microscopy with elemental microanalysis, Fourier transformed infrared micro-spectroscopy (micro-FTIR), and X-ray powder micro-diffraction (micro-XRD). Micro-Raman measurements were largely hindered by fluorescence. The choice of the analytical methods meets the contemporary requirement of a detailed description of various components in heterogeneous and minute samples of paint layers without their destruction. It is beneficial to use the combination of phase sensitive methods such as micro-FTIR and micro-XRD, because it allows the identification of both mineral-type and verdigris-type copper pigments in one paint layer. In addition, preliminary results concerning the study of the loss of crystallinity of verdigris-type pigments in proteinaceous binding media and the effect of lead white and lead tin yellow as highly absorbing matrix on verdigris identification in paint layers are reported. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Analytical techniques for biopharmaceutical development

    National Research Council Canada - National Science Library

    Wehr, Tim; Rodríguez-Díaz, Roberto; Tuck, Stephen (Stephen F.)

    2005-01-01

    ... for biopharmaceutical development / Tim Wehr, Roberto RodriguezDiaz, Stephen Tuck, editors. p. ; cm. Includes bibliographical references and index. ISBN 0-8247-2667-7 (alk. paper) 1. Protein drugs--Analysis--Laboratory manuals. [DNLM: 1. Pharmaceutical Preparations--analysis--Laboratory Manuals. 2. Biopharmaceutics--methods--Laboratory Ma...

  18. Surface-specific analytical techniques

    International Nuclear Information System (INIS)

    Riviere, J.C.

    1982-01-01

    The following methods are discussed: electron excitation (Auger electron spectroscopy; scanning Auger microscopy; electron energy-loss spectroscopy; appearance potential spectroscopy; electron-induced luminescence; electron-stimulated desorption); photon excitation (X-ray photoelectron spectroscopy; X-ray excited Auger electron spectroscopy; synchrotron radiation photoelectron spectroscopy; ultraviolet photoelectron spectroscopy; photoelectron spectromicroscopy; ellipsometry); ion excitation (ion-excited Auger electron spectroscopy; proton-excited Auger electron spectroscopy; ion neutralization spectroscopy; ion beam spectrochemical analysis; glow discharge optical spectroscopy; static secondary ion mass spectrometry; ion scattering spectroscopy; glow discharge mass spectrometry); resolution and sensitivity. (U.K.)

  19. Noise-immune cavity-enhanced analytical atomic spectrometry - NICE-AAS - A technique for detection of elements down to zeptogram amounts

    Science.gov (United States)

    Axner, Ove; Ehlers, Patrick; Hausmaninger, Thomas; Silander, Isak; Ma, Weiguang

    2014-10-01

    Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) is a powerful technique for detection of molecular compounds in gas phase that is based on a combination of two important concepts: frequency modulation spectroscopy (FMS) for reduction of noise, and cavity enhancement, for prolongation of the interaction length between the light and the sample. Due to its unique properties, it has demonstrated unparalleled detection sensitivity when it comes to detection of molecular constituents in the gas phase. However, despite these, it has so far not been used for detection of atoms, i.e. for elemental analysis. The present work presents an assessment of the expected performance of Doppler-broadened (Db) NICE-OHMS for analytical atomic spectrometry, then referred to as noise-immune cavity-enhanced analytical atomic spectrometry (NICE-AAS). After a description of the basic principles of Db-NICE-OHMS, the modulation and detection conditions for optimum performance are identified. Based on a previous demonstrated detection sensitivity of Db-NICE-OHMS of 5 × 10- 12 cm- 1 Hz- 1/2 (corresponding to a single-pass absorbance of 7 × 10- 11 over 10 s), the expected limits of detection (LODs) of Hg and Na by NICE-AAS are estimated. Hg is assumed to be detected in gas phase directly while Na is considered to be atomized in a graphite furnace (GF) prior to detection. It is shown that in the absence of spectral interferences, contaminated sample compartments, and optical saturation, it should be feasible to detect Hg down to 10 zg/cm3 (10 fg/m3 or 10- 5 ng/m3), which corresponds to 25 atoms/cm3, and Na down to 0.5 zg (zg = zeptogram = 10- 21 g), representing 50 zg/mL (parts-per-sextillion, pps, 1:1021) in liquid solution (assuming a sample of 10 μL) or solely 15 atoms injected into the GF, respectively. These LODs are several orders of magnitude lower (better) than any previous laser-based absorption technique previously demonstrated under atmospheric

  20. Evaluation of the quality of results obtained in institutions participating in interlaboratory experiments and of the reliability characteristics of the analytical methods used on the basis of certification of standard soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Parshin, A.K.; Obol' yaninova, V.G.; Sul' dina, N.P.

    1986-08-20

    Rapid monitoring of the level of pollution of the environment and, especially, of soils necessitates preparation of standard samples (SS) close in properties and material composition to the objects to be analyzed. During 1978-1982 four sets (three types of samples in each) of State Standard Samples of different soils were developed: soddy-podzolic sandy-loamy, typical chernozem, krasnozem, and calcareous sierozem. The certification studies of the SS of the soils were carried out in accordance with the classical scheme of interlab experiment (ILE). More than 100 institutions were involved in the ILE and the total number of independent analytical results was of the order of 10/sup 4/. With such a volume of analytical information at their disposal they were able to find some general characteristics intrinsic to certification studies, to assess the quality of work of the ILE participants with due regard for their specialization, and the reliability characteristics of the analytical methods used.