WorldWideScience

Sample records for standard analytical methods

  1. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  2. Determination of perfluorinated compounds in human plasma and serum standard reference materials using independent analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Jessica L. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Phinney, Karen W. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States)

    2011-11-15

    Perfluorinated compounds (PFCs) were measured in three National Institute of Standards and Technology (NIST) Standard Reference Materials (SRMs) (SRMs 1950 Metabolites in Human Plasma, SRM 1957 Organic Contaminants in Non-fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum) using two analytical approaches. The methods offer some independence, with two extraction types and two liquid chromatographic separation methods. The first extraction method investigated the acidification of the sample followed by solid-phase extraction (SPE) using a weak anion exchange cartridge. The second method used an acetonitrile extraction followed by SPE using a graphitized non-porous carbon cartridge. The extracts were separated using a reversed-phase C{sub 8} stationary phase and a pentafluorophenyl (PFP) stationary phase. Measured values from both methods for the two human serum SRMs, 1957 and 1958, agreed with reference values on the Certificates of Analysis. Perfluorooctane sulfonate (PFOS) values were obtained for the first time in human plasma SRM 1950 with good reproducibility among the methods (below 5% relative standard deviation). The nominal mass interference from taurodeoxycholic acid, which has caused over estimation of the amount of PFOS in biological samples, was separated from PFOS using the PFP stationary phase. Other PFCs were also detected in SRM 1950 and are reported. SRM 1950 can be used as a control material for human biomonitoring studies and as an aid to develop new measurement methods. (orig.)

  3. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  4. Standard errors and confidence intervals for correlations corrected for indirect range restriction: A simulation study comparing analytic and bootstrap methods.

    Science.gov (United States)

    Kennet-Cohen, Tamar; Kleper, Dvir; Turvall, Elliot

    2018-02-01

    A frequent topic of psychological research is the estimation of the correlation between two variables from a sample that underwent a selection process based on a third variable. Due to indirect range restriction, the sample correlation is a biased estimator of the population correlation, and a correction formula is used. In the past, bootstrap standard error and confidence intervals for the corrected correlations were examined with normal data. The present study proposes a large-sample estimate (an analytic method) for the standard error, and a corresponding confidence interval for the corrected correlation. Monte Carlo simulation studies involving both normal and non-normal data were conducted to examine the empirical performance of the bootstrap and analytic methods. Results indicated that with both normal and non-normal data, the bootstrap standard error and confidence interval were generally accurate across simulation conditions (restricted sample size, selection ratio, and population correlations) and outperformed estimates of the analytic method. However, with certain combinations of distribution type and model conditions, the analytic method has an advantage, offering reasonable estimates of the standard error and confidence interval without resorting to the bootstrap procedure's computer-intensive approach. We provide SAS code for the simulation studies. © 2017 The British Psychological Society.

  5. [Preparation of sub-standard samples and XRF analytical method of powder non-metallic minerals].

    Science.gov (United States)

    Kong, Qin; Chen, Lei; Wang, Ling

    2012-05-01

    In order to solve the problem that standard samples of non-metallic minerals are not satisfactory in practical work by X-ray fluorescence spectrometer (XRF) analysis with pressed powder pellet, a method was studied how to make sub-standard samples according to standard samples of non-metallic minerals and to determine how they can adapt to analysis of mineral powder samples, taking the K-feldspar ore in Ebian-Wudu, Sichuan as an example. Based on the characteristic analysis of K-feldspar ore and the standard samples by X-ray diffraction (XRD) and chemical methods, combined with the principle of the same or similar between the sub-standard samples and unknown samples, the experiment developed the method of preparation of sub-standard samples: both of the two samples above mentioned should have the same kind of minerals and the similar chemical components, adapt mineral processing, and benefit making working curve. Under the optimum experimental conditions, a method for determination of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, K2O and Na2O of K-feldspar ore by XRF was established. Thedetermination results are in good agreement with classical chemical methods, which indicates that this method was accurate.

  6. Orthogonal analytical methods for botanical standardization: Determination of green tea catechins by qNMR and LC-MS/MS

    OpenAIRE

    Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.

    2013-01-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development o...

  7. Echinacea standardization: analytical methods for phenolic compounds and typical levels in medicinal species.

    Science.gov (United States)

    Perry, N B; Burgess, E J; Glennie, V L

    2001-04-01

    A proposed standard extraction and HPLC analysis method has been used to measure typical levels of various phenolic compounds in the medicinally used Echinacea species. Chicoric acid was the main phenolic in E. purpurea roots (mean 2.27% summer, 1.68% autumn) and tops (2.02% summer, 0.52% autumn), and echinacoside was the main phenolic in E. angustifolia (1.04%) and E. pallida roots (0.34%). Caftaric acid was the other main phenolic compound in E. purpurea roots (0.40% summer, 0.35% autumn) and tops (0.82% summer, 0.18% autumn), and cynarin was a characteristic component of E. angustifolia roots (0.12%). Enzymatic browning during extraction could reduce the measured levels of phenolic compounds by >50%. Colorimetric analyses for total phenolics correlated well with the HPLC results for E. purpurea and E. angustifolia, but the colorimetric method gave higher values.

  8. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  9. Ficus deltoidea Standardization: Analytical Methods for Bioactive Markers in Deltozide Tablet 200 MG

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Zainah Adam; Rosniza Razali

    2016-01-01

    Standardization of herbal materials based on their chemical and biological profile is an important prerequisite for development of herbal product. The phyto pharmaceutical product that has been developed by Medical Technology Division, Malaysian Nuclear Agency is DELTOZIDE TABLET 200 MG containing 200 mg of spray-dried aqueous extract of Ficus deltoidea var kunstleri leaf as the active ingredient. Ficus deltoidea Jack or locally known as Mas Cotek is a South East Asian native plant traditionally used to treat several diseases. Pharmacological data showed that this plant exhibited good antioxidant, anti-diabetic and anti-inflammatory properties. It is important to establish the chemical profiles and determine the phytochemicals content of this plant as it is popularly used in traditional medicines. Thus, the present study reports on the comprehensive phytochemicals evaluation of bioactive markers from this extract for the development of DELTOZIDE TABLET 200 MG . Characterization of extract using LCMS/ MS Triple TOF System showed the presence of major constituents representing vitexin, isovitexin, gallic acid, catechinic, api genin, epicatechin and caffeoylquinic acid along with other minor constituents. The extract was standardized by ultra-high performance liquid chromatography (UHPLC) using two pharmacologically active markers, vitexin and isovitexin. Furthermore, qualitative determination of phytochemicals showed the presence of important phyto-constituents namely anthraquinones, terpenoids, flavonoids, tannins, phlobatannins, alkaloids, saponins, cardiac glycosides, steroids and phenols in the aqueous extract of Ficus deltoidea. Quantitative determination of phytochemicals revealed that the amount of total phenolic content (TPC; Gallic acid as standard) and total flavonoid content (TFC; Quercetin as standard) were 126.67±3.98 mg GAE/ g extract and 9.08±0.36 mg QE/ g extract respectively. The generated data provides some explanation for its wide usage in

  10. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. 7 CFR 91.23 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ...-2417. (i) Standard Analytical Methods of the Member Companies of Corn Industries Research Foundation... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...

  12. Yarn supplier selection using analytical hierarchy process (AHP) and standardized unitless rating (SUR) method on textile industry

    Science.gov (United States)

    Erfaisalsyah, M. H.; Mansur, A.; Khasanah, A. U.

    2017-11-01

    For a company which engaged in the textile field, specify the supplier of raw materials for production is one important part of supply chain management which can affect the company's business processes. This study aims to identify the best suppliers of raw material suppliers of yarn for PC. PKBI based on several criteria. In this study, the integration between the Analytical Hierarchy Process (AHP) and the Standardized Unitless Rating (SUR) are used to assess the performance of the suppliers. By using AHP, it can be known the value of the relative weighting of each criterion. While SUR shows the sequence performance value of the supplier. The result of supplier ranking calculation can be used to know the strengths and weaknesses of each supplier based on its performance criteria. From the final result, it can be known which suppliers should improve their performance in order to create long term cooperation with the company.

  13. Normalisation of conventional analytical methods (XRF And icp) on NAA using different kinds Of geological standard reference material

    International Nuclear Information System (INIS)

    Bounakhla, M.; Embarch, K.; Zahry, F.; Gaudry, A.; Piccot, D.; Gruffat, J.J.; Moutte, J.; Bilal, E.

    2001-01-01

    The aim of this work is the comparison between INAA (Instrumental Neutron Activation Analysis), XRF (X-ray Fluorescence) Analysis and ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry) methods for geological samples. The study had been done on 15 standard reference materials (SRM) of different kind of rocks having different origins. For INAA, the irradiation was made in Pierre-Sue Laboratory in France using two reactors, OSIRIS for irradiation with epithermal neutron and ORPHEE for thermal neutron irradiation. Two protocols of irradiation were performed, the first one under cadmium to eliminate thermal neutrons and the second one with a high flux ratio of thermal to epithermal neutrons (f=2000). Concerning XRF, we used two techniques : Energy Dispersive XRF and Wave-length XRF. The ICP-AES spectrometer used was a sequential. In this comparison study, we first normalized the INAA results on the certified values. The measurements of the conventional methods (XRF and ICP-AES) had been normalized on both of INAA results and the certified values. The function used in the fitting of the measured and certified values were a gaussian. It was concluded that both of the conventional methods complement in many cases the results of INAA, but their main disadvantage was poor sensitivity (especially for XRF) in the determination of trace elements, mainly rare elements. However, the conventional methods are necessary in rocks characterization throw major elements determination

  14. Role of sediment-trace element chemistry in water-quality monitoring and the need for standard analytical methods

    Science.gov (United States)

    Horowitz, Arthur J.

    1991-01-01

    Multiple linear regression models calculated from readily obtainable chemical and physical parameters can explain a high percentage (70% or greater) of observed sediment trace-element variance for Cu, Zn, Pb, Cr, Ni, Co, As, Sb, Se, and Hg. Almost all the factors used in the various models fall into the category of operational definitions (e.g., grain size, surface area, and geochemical substrates such as amorphous iron and manganese oxides). Thus, the concentrations and distributions used in the various models are operationally defined, and are subject to substantial change depending on the method used to determine them. Without standardized procedures, data from different sources are not comparable, and the utility and applicability of the various models would be questionable.

  15. Analytical methods under emergency conditions

    International Nuclear Information System (INIS)

    Sedlet, J.

    1983-01-01

    This lecture discusses methods for the radiochemical determination of internal contamination of the body under emergency conditions, here defined as a situation in which results on internal radioactive contamination are needed quickly. The purpose of speed is to determine the necessity for medical treatment to increase the natural elimination rate. Analytical methods discussed include whole-body counting, organ counting, wound monitoring, and excreta analysis. 12 references

  16. Establishment of a Standard Analytical Model of Distribution Network with Distributed Generators and Development of Multi Evaluation Method for Network Configuration Candidates

    Science.gov (United States)

    Hayashi, Yasuhiro; Kawasaki, Shoji; Matsuki, Junya; Matsuda, Hiroaki; Sakai, Shigekazu; Miyazaki, Teru; Kobayashi, Naoki

    Since a distribution network has many sectionalizing switches, there are huge radial network configuration candidates by states (opened or closed) of sectionalizing switches. Recently, the total number of distributed generation such as photovoltaic generation system and wind turbine generation system connected to the distribution network is drastically increased. The distribution network with the distributed generators must be operated keeping reliability of power supply and power quality. Therefore, the many configurations of the distribution network with the distributed generators must be evaluated multiply from various viewpoints such as distribution loss, total harmonic distortion, voltage imbalance and so on. In this paper, the authors propose a multi evaluation method to evaluate the distribution network configuration candidates satisfied with constraints of voltage and line current limit from three viewpoints ((1) distribution loss, (2) total harmonic distortion and (3) voltage imbalance). After establishing a standard analytical model of three sectionalized and three connected distribution network configuration with distributed generators based on the practical data, the multi evaluation for the established model is carried out by using the proposed method based on EMTP (Electro-Magnetic Transients Programs).

  17. Decision analytic methods in RODOS

    International Nuclear Information System (INIS)

    Borzenko, V.; French, S.

    1996-01-01

    In the event of a nuclear accident, RODOS seeks to provide decision support at all levels ranging from the largely descriptive to providing a detailed evaluation of the benefits and disadvantages of various countermeasure strategies and ranking them according to the societal preferences as perceived by the decision makers. To achieve this, it must draw upon several decision analytic methods and bring them together in a coherent manner so that the guidance offered to decision makers is consistent from one stage of an accident to the next. The methods used draw upon multi-attribute value and utility theories

  18. Journal article reporting standards for qualitative primary, qualitative meta-analytic, and mixed methods research in psychology: The APA Publications and Communications Board task force report

    OpenAIRE

    Levitt, H. M.; Bamberg, M.; Creswell, J. W.; Frost, D. M.; Josselson, R.; Suárez-Orozco, C.

    2018-01-01

    The American Psychological Association Publications and Communications Board Working Group on Journal Article Reporting Standards for Qualitative Research (JARS–Qual Working Group) was charged with examining the state of journal article reporting standards as they applied to qualitative research and with generating recommendations for standards that would be appropriate for a wide range of methods within the discipline of psychology. These standards describe what should be included in a resea...

  19. Journal article reporting standards for qualitative primary, qualitative meta-analytic, and mixed methods research in psychology: The APA Publications and Communications Board task force report.

    Science.gov (United States)

    Levitt, Heidi M; Bamberg, Michael; Creswell, John W; Frost, David M; Josselson, Ruthellen; Suárez-Orozco, Carola

    2018-01-01

    The American Psychological Association Publications and Communications Board Working Group on Journal Article Reporting Standards for Qualitative Research (JARS-Qual Working Group) was charged with examining the state of journal article reporting standards as they applied to qualitative research and with generating recommendations for standards that would be appropriate for a wide range of methods within the discipline of psychology. These standards describe what should be included in a research report to enable and facilitate the review process. This publication marks a historical moment-the first inclusion of qualitative research in APA Style, which is the basis of both the Publication Manual of the American Psychological Association (APA, 2010) and APA Style CENTRAL, an online program to support APA Style. In addition to the general JARS-Qual guidelines, the Working Group has developed standards for both qualitative meta-analysis and mixed methods research. The reporting standards were developed for psychological qualitative research but may hold utility for a broad range of social sciences. They honor a range of qualitative traditions, methods, and reporting styles. The Working Group was composed of a group of researchers with backgrounds in varying methods, research topics, and approaches to inquiry. In this article, they present these standards and their rationale, and they detail the ways that the standards differ from the quantitative research reporting standards. They describe how the standards can be used by authors in the process of writing qualitative research for submission as well as by reviewers and editors in the process of reviewing research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  20. Sensor Network Information Analytical Methods: Analysis of Similarities and Differences

    Directory of Open Access Journals (Sweden)

    Chen Jian

    2014-04-01

    Full Text Available In the Sensor Network information engineering literature, few references focus on the definition and design of Sensor Network information analytical methods. Among those that do are Munson, et al. and the ISO standards on functional size analysis. To avoid inconsistent vocabulary and potentially incorrect interpretation of data, Sensor Network information analytical methods must be better designed, including definitions, analysis principles, analysis rules, and base units. This paper analyzes the similarities and differences across three different views of analytical methods, and uses a process proposed for the design of Sensor Network information analytical methods to analyze two examples of such methods selected from the literature.

  1. Evaluation of the quality of results obtained in institutions participating in interlaboratory experiments and of the reliability characteristics of the analytical methods used on the basis of certification of standard soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Parshin, A.K.; Obol' yaninova, V.G.; Sul' dina, N.P.

    1986-08-20

    Rapid monitoring of the level of pollution of the environment and, especially, of soils necessitates preparation of standard samples (SS) close in properties and material composition to the objects to be analyzed. During 1978-1982 four sets (three types of samples in each) of State Standard Samples of different soils were developed: soddy-podzolic sandy-loamy, typical chernozem, krasnozem, and calcareous sierozem. The certification studies of the SS of the soils were carried out in accordance with the classical scheme of interlab experiment (ILE). More than 100 institutions were involved in the ILE and the total number of independent analytical results was of the order of 10/sup 4/. With such a volume of analytical information at their disposal they were able to find some general characteristics intrinsic to certification studies, to assess the quality of work of the ILE participants with due regard for their specialization, and the reliability characteristics of the analytical methods used.

  2. Analytical methods used at model facility

    International Nuclear Information System (INIS)

    Wing, N.S.

    1984-01-01

    A description of analytical methods used at the model LEU Fuel Fabrication Facility is presented. The methods include gravimetric uranium analysis, isotopic analysis, fluorimetric analysis, and emission spectroscopy

  3. Big data analytics methods and applications

    CERN Document Server

    Rao, BLS; Rao, SB

    2016-01-01

    This book has a collection of articles written by Big Data experts to describe some of the cutting-edge methods and applications from their respective areas of interest, and provides the reader with a detailed overview of the field of Big Data Analytics as it is practiced today. The chapters cover technical aspects of key areas that generate and use Big Data such as management and finance; medicine and healthcare; genome, cytome and microbiome; graphs and networks; Internet of Things; Big Data standards; bench-marking of systems; and others. In addition to different applications, key algorithmic approaches such as graph partitioning, clustering and finite mixture modelling of high-dimensional data are also covered. The varied collection of themes in this volume introduces the reader to the richness of the emerging field of Big Data Analytics.

  4. 7 CFR 94.4 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...) FDA Bacteriological Analytical Manual (BAM), AOAC INTERNATIONAL, 481 North Frederick Avenue, Suite 500...

  5. HTGR analytical methods and design verification

    International Nuclear Information System (INIS)

    Neylan, A.J.; Northup, T.E.

    1982-05-01

    Analytical methods for the high-temperature gas-cooled reactor (HTGR) include development, update, verification, documentation, and maintenance of all computer codes for HTGR design and analysis. This paper presents selected nuclear, structural mechanics, seismic, and systems analytical methods related to the HTGR core. This paper also reviews design verification tests in the reactor core, reactor internals, steam generator, and thermal barrier

  6. High pressure size exclusion chromatography (HPSEC) determination of dissolved organic matter molecular weight revisited: Accounting for changes in stationary phases, analytical standards, and isolation methods

    Science.gov (United States)

    McAdams, Brandon C.; Aiken, George R.; McKnight, Diane M.; Arnold, William A.; Chin, Yu-Ping

    2018-01-01

    We reassessed the molecular weight of dissolved organic matter (DOM) determined by high pressure size exclusion chromatography (HPSEC) using measurements made with different columns and various generations of polystyrenesulfonate (PSS) molecular weight standards. Molecular weight measurements made with a newer generation HPSEC column and PSS standards from more recent lots are roughly 200 to 400 Da lower than initial measurements made in the early 1990s. These updated numbers match DOM molecular weights measured by colligative methods and fall within a range of values calculated from hydroxyl radical kinetics. These changes suggest improved accuracy of HPSEC molecular weight measurements that we attribute to improved accuracy of PSS standards and changes in the column packing. We also isolated DOM from wetlands in the Prairie Pothole Region (PPR) using XAD-8, a cation exchange resin, and PPL, a styrene-divinylbenzene media, and observed little difference in molecular weight and specific UV absorbance at 280 nm (SUVA280) between the two solid phase extraction resins, suggesting they capture similar DOM moieties. PPR DOM also showed lower SUVA280 at similar weights compared to DOM isolates from a global range of environments, which we attribute to oxidized sulfur in PPR DOM that would increase molecular weight without affecting SUVA280.

  7. High Pressure Size Exclusion Chromatography (HPSEC) Determination of Dissolved Organic Matter Molecular Weight Revisited: Accounting for Changes in Stationary Phases, Analytical Standards, and Isolation Methods.

    Science.gov (United States)

    McAdams, Brandon C; Aiken, George R; McKnight, Diane M; Arnold, William A; Chin, Yu-Ping

    2018-01-16

    We reassessed the molecular weight of dissolved organic matter (DOM) determined by high pressure size exclusion chromatography (HPSEC) using measurements made with different columns and various generations of polystyrenesulfonate (PSS) molecular weight standards. Molecular weight measurements made with a newer generation HPSEC column and PSS standards from more recent lots are roughly 200 to 400 Da lower than initial measurements made in the early 1990s. These updated numbers match DOM molecular weights measured by colligative methods and fall within a range of values calculated from hydroxyl radical kinetics. These changes suggest improved accuracy of HPSEC molecular weight measurements that we attribute to improved accuracy of PSS standards and changes in the column packing. We also isolated DOM from wetlands in the Prairie Pothole Region (PPR) using XAD-8, a cation exchange resin, and PPL, a styrene-divinylbenzene media, and observed little difference in molecular weight and specific UV absorbance at 280 nm (SUVA 280 ) between the two solid phase extraction resins, suggesting they capture similar DOM moieties. PPR DOM also showed lower SUVA 280 at similar weights compared to DOM isolates from a global range of environments, which we attribute to oxidized sulfur in PPR DOM that would increase molecular weight without affecting SUVA 280 .

  8. Applying standards to systematize learning analytics in serious games

    NARCIS (Netherlands)

    Serrano-Laguna, Angel; Martinez-Ortiz, Ivan; Haag, Jason; Regan, Damon; Johnson, Andy; Fernandez-Manjon, Baltasar

    2016-01-01

    Learning Analytics is an emerging field focused on analyzing learners’ interactions with educational content. One of the key open issues in learning analytics is the standardization of the data collected. This is a particularly challenging issue in serious games, which generate a diverse range of

  9. Analytical standards for accountability of uranium hexafluoride - 1972

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    An analytical standard for the accountability of uranium hexafluoride is presented that includes procedures for subsampling, determination of uranium, determination of metallic impurities and isotopic analysis by gas and thermal ionization mass spectrometry

  10. New safety standards for large volume vans and light transporters - optimized with analytical crash simulation methods; Neue Sicherheitsstandards bei Grossraum-Limousinen und Leicht-Transportern - Optimierung durch konsequente Unterstuetzung mittels rechnerischer Crash-Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Alber, P.; Boelke, D.

    1996-04-01

    Under the pseudonym of T0, two parallel vehicle developments where conducted. One lead to a one ton commercial vehicle class transporter (Vito) and the other to comfortable large colume van (V-class). Both of these vehicles share common body-in-white structural components based on the high standards of passenger vehicle specifications. Consequently, analytical methods were applied to an even larger extent than with the bigger brother `Sprinter` beginning with the preliminary design phases, continuing through the development phases and ending with the optimized production version. Completely new vehicle concepts led themselves to the application of modern analytical methods. (orig.) [Deutsch] Unter dem Pseudonym T0 wurden zwei Entwicklungen parallel betrieben, die zum einen in einem Transporter der Ein-Tonnen-Nutzlast-Klasse (Vito) und zum anderen in einer komfortablen Grossraum-Limousine (V-Klasse) muendeten. Beiden gemeinsam ist neben einer hohen Anzahl von Gleichteilen der Rohbau-Struktur das Sicherheits-Konzept, das sich am bekannt hohen Standard des Pkw-Lastenheftes misst. Pkw-Sicherheits-Standard bedeutet Sicherheit rundum, und es wurde in noch staerkerem Masse wie beim grossen Bruder `Sprinter` die rechnerische Simulation konsequent von der Vordimensionierung in der Vorentwicklungs-Phase ueber saemtliche Entwicklungs-Iterationsschleifen bis zur optimierten Serienreife herangezogen. Ein von Grund auf neues Fahrzeug-Konzept liess moderner Berechnungstechnik besondere Bedeutung zukommen. (orig.)

  11. Analytical methods of radwaste characterization

    International Nuclear Information System (INIS)

    Garcia, C.M.

    1994-10-01

    In view of the need to carry out more extensive studies on the design of newly proposed methods for the treatment of radioactive wastes collected at PNRI, this study is aimed to provide a guide in the characterization of wastes which is a preparatory step for a well-planned waste processing. (auth.). 8 refs

  12. A New Method to Study Analytic Inequalities

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Zhang

    2010-01-01

    Full Text Available We present a new method to study analytic inequalities involving n variables. Regarding its applications, we proved some well-known inequalities and improved Carleman's inequality.

  13. Synergistic relationships between Analytical Chemistry and written standards

    International Nuclear Information System (INIS)

    Valcárcel, Miguel; Lucena, Rafael

    2013-01-01

    Graphical abstract: -- Highlights: •Analytical Chemistry is influenced by international written standards. •Different relationships can be established between them. •Synergies can be generated when these standards are conveniently managed. -- Abstract: This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived

  14. Synergistic relationships between Analytical Chemistry and written standards

    Energy Technology Data Exchange (ETDEWEB)

    Valcárcel, Miguel, E-mail: qa1vacam@uco.es; Lucena, Rafael

    2013-07-25

    Graphical abstract: -- Highlights: •Analytical Chemistry is influenced by international written standards. •Different relationships can be established between them. •Synergies can be generated when these standards are conveniently managed. -- Abstract: This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived.

  15. Solving signal instability to maintain the second-order advantage in the resolution and determination of multi-analytes in complex systems by modeling liquid chromatography-mass spectrometry data using alternating trilinear decomposition method assisted with piecewise direct standardization.

    Science.gov (United States)

    Gu, Hui-Wen; Wu, Hai-Long; Yin, Xiao-Li; Li, Shan-Shan; Liu, Ya-Juan; Xia, Hui; Xie, Li-Xia; Yu, Ru-Qin; Yang, Peng-Yuan; Lu, Hao-Jie

    2015-08-14

    The application of calibration transfer methods has been successful in combination with near-infrared spectroscopy or other tools for prediction of chemical composition. One of the developed methods that can provide accurate performances is the piecewise direct standardization (PDS) method, which in this paper is firstly applied to transfer from one day to another the second-order calibration model based on alternating trilinear decomposition (ATLD) method built for the interference-free resolution and determination of multi-analytes in complex systems by liquid chromatography-mass spectrometry (LC-MS) in full scan mode. This is an example of LC-MS analysis in which interferences have been found, making necessary the use of second-order calibration because of its capacity for modeling this phenomenon, which implies analytes of interest can be resolved and quantified even in the presence of overlapped peaks and unknown interferences. Once the second-order calibration model based on ATLD method was built, the calibration transfer was conducted to compensate for the signal instability of LC-MS instrument over time. This allows one to reduce the volume of the heavy works for complete recalibration which is necessary for later accurate determinations. The root-mean-square error of prediction (RMSEP) and average recovery were used to evaluate the performances of the proposed strategy. Results showed that the number of calibration samples used on the real LC-MS data was reduced by using the PDS method from 11 to 3 while producing comparable RMSEP values and recovery values that were statistically the same (F-test, 95% confidence level) to those obtained with 11 calibration samples. This methodology is in accordance with the highly recommended green analytical chemistry principles, since it can reduce the experimental efforts and cost with regard to the use of a new calibration model built in modified conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Analytical and computational methods in electromagnetics

    CERN Document Server

    Garg, Ramesh

    2008-01-01

    This authoritative resource offers you clear and complete explanation of this essential electromagnetics knowledge, providing you with the analytical background you need to understand such key approaches as MoM (method of moments), FDTD (Finite Difference Time Domain) and FEM (Finite Element Method), and Green's functions. This comprehensive book includes all math necessary to master the material.

  17. Mathematical methods for physical and analytical chemistry

    CERN Document Server

    Goodson, David Z

    2011-01-01

    Mathematical Methods for Physical and Analytical Chemistry presents mathematical and statistical methods to students of chemistry at the intermediate, post-calculus level. The content includes a review of general calculus; a review of numerical techniques often omitted from calculus courses, such as cubic splines and Newton's method; a detailed treatment of statistical methods for experimental data analysis; complex numbers; extrapolation; linear algebra; and differential equations. With numerous example problems and helpful anecdotes, this text gives chemistry students the mathematical

  18. Synthetic salt cake standards for analytical laboratory quality control

    International Nuclear Information System (INIS)

    Schilling, A.E.; Miller, A.G.

    1980-01-01

    The validation of analytical results in the characterization of Hanford Nuclear Defense Waste requires the preparation of synthetic waste for standard reference materials. Two independent synthetic salt cake standards have been prepared to monitor laboratory quality control for the chemical characterization of high-level salt cake and sludge waste in support of Rockwell Hanford Operations' High-Level Waste Management Program. Each synthetic salt cake standard contains 15 characterized chemical species and was subjected to an extensive verification/characterization program in two phases. Phase I consisted of an initial verification of each analyte in salt cake form in order to determine the current analytical capability for chemical analysis. Phase II consisted of a final characterization of those chemical species in solution form where conflicting verification data were observed. The 95 percent confidence interval on the mean for the following analytes within each standard is provided: sodium, nitrate, nitrite, phosphate, carbonate, sulfate, hydroxide, chromate, chloride, fluoride, aluminum, plutonium-239/240, strontium-90, cesium-137, and water

  19. 7 CFR 93.13 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods. Official analyses for peanuts, nuts, corn, oilseeds, and related vegetable oils are found in the following..., Englewood Cliffs, New Jersey 07632. (c) Analyst's Instruction for Aflatoxin (August 1994), S&T Instruction...

  20. Biodiesel Analytical Methods: August 2002--January 2004

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerpen, J.; Shanks, B.; Pruszko, R.; Clements, D.; Knothe, G.

    2004-07-01

    Biodiesel is an alternative fuel for diesel engines that is receiving great attention worldwide. The material contained in this book is intended to provide the reader with information about biodiesel engines and fuels, analytical methods used to measure fuel properties, and specifications for biodiesel quality control.

  1. Analytic methods to generate integrable mappings

    Indian Academy of Sciences (India)

    2015-10-22

    Oct 22, 2015 ... Systematic analytic methods of deriving integrable mappings from integrable nonlinear ordinary differential, differential-difference and lattice equations are presented. More specifically, we explain how to derive integrable mappings through four different techniques namely,. dis-cretization technique,; Lax ...

  2. Numerical and analytical methods with Matlab

    CERN Document Server

    Bober, William; Masory, Oren

    2013-01-01

    Numerical and Analytical Methods with MATLAB® presents extensive coverage of the MATLAB programming language for engineers. It demonstrates how the built-in functions of MATLAB can be used to solve systems of linear equations, ODEs, roots of transcendental equations, statistical problems, optimization problems, control systems problems, and stress analysis problems. These built-in functions are essentially black boxes to students. By combining MATLAB with basic numerical and analytical techniques, the mystery of what these black boxes might contain is somewhat alleviated. This classroom-tested

  3. Prioritizing pesticide compounds for analytical methods development

    Science.gov (United States)

    Norman, Julia E.; Kuivila, Kathryn; Nowell, Lisa H.

    2012-01-01

    The U.S. Geological Survey (USGS) has a periodic need to re-evaluate pesticide compounds in terms of priorities for inclusion in monitoring and studies and, thus, must also assess the current analytical capabilities for pesticide detection. To meet this need, a strategy has been developed to prioritize pesticides and degradates for analytical methods development. Screening procedures were developed to separately prioritize pesticide compounds in water and sediment. The procedures evaluate pesticide compounds in existing USGS analytical methods for water and sediment and compounds for which recent agricultural-use information was available. Measured occurrence (detection frequency and concentrations) in water and sediment, predicted concentrations in water and predicted likelihood of occurrence in sediment, potential toxicity to aquatic life or humans, and priorities of other agencies or organizations, regulatory or otherwise, were considered. Several existing strategies for prioritizing chemicals for various purposes were reviewed, including those that identify and prioritize persistent, bioaccumulative, and toxic compounds, and those that determine candidates for future regulation of drinking-water contaminants. The systematic procedures developed and used in this study rely on concepts common to many previously established strategies. The evaluation of pesticide compounds resulted in the classification of compounds into three groups: Tier 1 for high priority compounds, Tier 2 for moderate priority compounds, and Tier 3 for low priority compounds. For water, a total of 247 pesticide compounds were classified as Tier 1 and, thus, are high priority for inclusion in analytical methods for monitoring and studies. Of these, about three-quarters are included in some USGS analytical method; however, many of these compounds are included on research methods that are expensive and for which there are few data on environmental samples. The remaining quarter of Tier 1

  4. Analytical detection methods for irradiated foods

    International Nuclear Information System (INIS)

    1991-03-01

    The present publication is a review of scientific literature on the analytical identification of foods treated with ionizing radiation and the quantitative determination of absorbed dose of radiation. Because of the extremely low level of chemical changes resulting from irradiation or because of the lack of specificity to irradiation of any chemical changes, a few methods of quantitative determination of absorbed dose have shown promise until now. On the other hand, the present review has identified several possible methods, which could be used, following further research and testing, for the identification of irradiated foods. An IAEA Co-ordinated Research Programme on Analytical Detection Methods for Irradiation Treatment of Food ('ADMIT'), established in 1990, is currently investigating many of the methods cited in the present document. Refs and tab

  5. Workshop on Analytical Methods in Statistics

    CERN Document Server

    Jurečková, Jana; Maciak, Matúš; Pešta, Michal

    2017-01-01

    This volume collects authoritative contributions on analytical methods and mathematical statistics. The methods presented include resampling techniques; the minimization of divergence; estimation theory and regression, eventually under shape or other constraints or long memory; and iterative approximations when the optimal solution is difficult to achieve. It also investigates probability distributions with respect to their stability, heavy-tailness, Fisher information and other aspects, both asymptotically and non-asymptotically. The book not only presents the latest mathematical and statistical methods and their extensions, but also offers solutions to real-world problems including option pricing. The selected, peer-reviewed contributions were originally presented at the workshop on Analytical Methods in Statistics, AMISTAT 2015, held in Prague, Czech Republic, November 10-13, 2015.

  6. Nuclear analytical methods for platinum group elements

    International Nuclear Information System (INIS)

    2005-04-01

    Platinum group elements (PGE) are of special interest for analytical research due to their economic importance like chemical peculiarities as catalysts, medical applications as anticancer drugs, and possible environmental detrimental impact as exhaust from automobile catalyzers. Natural levels of PGE are so low in concentration that most of the current analytical techniques approach their limit of detection capacity. In addition, Ru, Rh, Pd, Re, Os, Ir, and Pt analyses still constitute a challenge in accuracy and precision of quantification in natural matrices. Nuclear analytical techniques, such as neutron activation analysis, X ray fluorescence, or proton-induced X ray emission (PIXE), which are generally considered as reference methods for many analytical problems, are useful as well. However, due to methodological restrictions, they can, in most cases, only be applied after pre-concentration and under special irradiation conditions. This report was prepared following a coordinated research project and a consultants meeting addressing the subject from different viewpoints. The experts involved suggested to discuss the issue according to the (1) application, hence, the concentration levels encountered, and (2) method applied for analysis. Each of the different fields of application needs special consideration for sample preparation, PGE pre-concentration, and determination. Additionally, each analytical method requires special attention regarding the sensitivity and sample type. Quality assurance/quality control aspects are considered towards the end of the report. It is intended to provide the reader of this publication with state-of-the-art information on the various aspects of PGE analysis and to advise which technique might be most suitable for a particular analytical problem related to platinum group elements. In particular, many case studies described in detail from the authors' laboratory experience might help to decide which way to go. As in many cases

  7. Synergistic relationships between Analytical Chemistry and written standards.

    Science.gov (United States)

    Valcárcel, Miguel; Lucena, Rafael

    2013-07-25

    This paper describes the mutual impact of Analytical Chemistry and several international written standards (norms and guides) related to knowledge management (CEN-CWA 14924:2004), social responsibility (ISO 26000:2010), management of occupational health and safety (OHSAS 18001/2), environmental management (ISO 14001:2004), quality management systems (ISO 9001:2008) and requirements of the competence of testing and calibration laboratories (ISO 17025:2004). The intensity of this impact, based on a two-way influence, is quite different depending on the standard considered. In any case, a new and fruitful approach to Analytical Chemistry based on these relationships can be derived. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Analytical methods for quantitation of prenylated flavonoids from hops

    Science.gov (United States)

    Nikolić, Dejan; van Breemen, Richard B.

    2013-01-01

    The female flowers of hops (Humulus lupulus L.) are used as a flavoring agent in the brewing industry. There is growing interest in possible health benefits of hops, particularly as estrogenic and chemopreventive agents. Among the possible active constituents, most of the attention has focused on prenylated flavonoids, which can chemically be classified as prenylated chalcones and prenylated flavanones. Among chalcones, xanthohumol (XN) and desmethylxanthohumol (DMX) have been the most studied, while among flavanones, 8-prenylnaringenin (8-PN) and 6-prenylnaringenin (6-PN) have received the most attention. Because of the interest in medicinal properties of prenylated flavonoids, there is demand for accurate, reproducible and sensitive analytical methods to quantify these compounds in various matrices. Such methods are needed, for example, for quality control and standardization of hop extracts, measurement of the content of prenylated flavonoids in beer, and to determine pharmacokinetic properties of prenylated flavonoids in animals and humans. This review summarizes currently available analytical methods for quantitative analysis of the major prenylated flavonoids, with an emphasis on the LC-MS and LC-MS-MS methods and their recent applications to biomedical research on hops. This review covers all methods in which prenylated flavonoids have been measured, either as the primary analytes or as a part of a larger group of analytes. The review also discusses methodological issues relating to the quantitative analysis of these compounds regardless of the chosen analytical approach. PMID:24077106

  9. Comparison of nuclear analytical methods with competitive methods

    International Nuclear Information System (INIS)

    1987-10-01

    The use of nuclear analytical techniques, especially neutron activation analysis, already have a 50 year old history. Today several sensitive and accurate, non-nuclear trace element analytical techniques are available and new methods are continuously developed. The IAEA is supporting the development of nuclear analytical laboratories in its Member States. In order to be able to advise the developing countries which methods to use in different applications, it is important to know the present status and development trends of nuclear analytical methods, what are their benefits, drawbacks and recommended fields of application, compared with other, non-nuclear techniques. In order to get an answer to these questions the IAEA convened this Advisory Group Meeting. This volume is the outcome of the presentations and discussions of the meeting. A separate abstract was prepared for each of the 21 papers. Refs, figs, tabs

  10. Analytical Methods for Detonation Residues of Insensitive Munitions

    Science.gov (United States)

    Walsh, Marianne E.

    2016-01-01

    Analytical methods are described for the analysis of post-detonation residues from insensitive munitions. Standard methods were verified or modified to obtain the mass of residues deposited per round. In addition, a rapid chromatographic separation was developed and used to measure the mass of NTO (3-nitro-1,2,4-triazol-5-one), NQ (nitroguanidine) and DNAN (2,4-dinitroanisole). The HILIC (hydrophilic-interaction chromatography) separation described here uses a trifunctionally-bonded amide phase to retain the polar analytes. The eluent is 75/25 v/v acetonitrile/water acidified with acetic acid, which is also suitable for LC/MS applications. Analytical runtime was three minutes. Solid phase extraction and LC/MS conditions are also described.

  11. Modern methods in analytical acoustics lecture notes

    CERN Document Server

    Crighton, D G; Williams, J E Ffowcs; Heckl, M; Leppington, F G

    1992-01-01

    Modern Methods in Analytical Acoustics considers topics fundamental to the understanding of noise, vibration and fluid mechanisms. The series of lectures on which this material is based began by some twenty five years ago and has been developed and expanded ever since. Acknowledged experts in the field have given this course many times in Europe and the USA. Although the scope of the course has widened considerably, the primary aim of teaching analytical techniques of acoustics alongside specific areas of wave motion and unsteady fluid mechanisms remains. The distinguished authors of this volume are drawn from Departments of Acoustics, Engineering of Applied Mathematics in Berlin, Cambridge and London. Their intention is to reach a wider audience of all those concerned with acoustic analysis than has been able to attend the course.

  12. Directory of Analytical Methods, Department 1820

    International Nuclear Information System (INIS)

    Whan, R.E.

    1986-01-01

    The Materials Characterization Department performs chemical, physical, and thermophysical analyses in support of programs throughout the Laboratories. The department has a wide variety of techniques and instruments staffed by experienced personnel available for these analyses, and we strive to maintain near state-of-the-art technology by continued updates. We have prepared this Directory of Analytical Methods in order to acquaint you with our capabilities and to help you identify personnel who can assist with your analytical needs. The descriptions of the various capabilities are requester-oriented and have been limited in length and detail. Emphasis has been placed on applications and limitations with notations of estimated analysis time and alternative or related techniques. A short, simplified discussion of underlying principles is also presented along with references if more detail is desired. The contents of this document have been organized in the order: bulky analysis, microanalysis, surface analysis, optical and thermal property measurements

  13. An analytical software for NAA by using K0-method

    International Nuclear Information System (INIS)

    A Jingye; Chen Da; Tu Jing; Chenweishi; Zhang Wenshou; Wang Daohua

    2003-01-01

    An analytical software has been designed for a personal computer in DOS environment to do reactor NAA by using K 0 -method. The system has functions of radionuclide identification, f and α calculation, K 0 -value calculation, quantitative calculation of elemental concentrations, nuclides' data management, experiment design, computer simulation etc. The analytical methods used in this system include absolute method, relative method and K 0 -method. Using this system, three gamma-ray spectra for NAA of Au, Zr samples and GBW07107 rock standard sample have been analyzed. The analysis results are in agreement with the certified results in the scope of uncertainties and the f and α values at the irradiation site in the UZrH pulse reactor are 36.6 and 0.044 respectively. (author)

  14. The Emergence of the Analytical Method

    DEFF Research Database (Denmark)

    Plum, Maja

    2012-01-01

    accountability, visibility and documentation. It is argued that pedagogy is generated as a sequential and unit-specified way of working on the production of ‘the learning child’, forming a time- and material-optimising approach. Hereby, the nursery teacher, as a daily scientific researcher, comes to serve...... the nation by an ongoing observational intervention, producing the learning foundation for the entrepreneurial citizen, and thus the nation as a knowledge society in a globalised world. This is what this article terms the emergence of the analytical method....

  15. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  16. Analytical N beam position monitor method

    Science.gov (United States)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  17. Determination of elements by nuclear analytical methods.

    Science.gov (United States)

    Weise, H P; Görner, W; Hedrich, M

    2001-01-01

    The working principle of nuclear analytical methods (NAMs) is not influenced by the chemical bond. Consequently, they are independent counterparts to the well-known chemical procedures. NAMs obey fundamental laws or can be described and understood thoroughly. This qualifies them as candidates for reference methods. Although following similar nuclear reaction schemes, they comprise bulk analyzing capability (neutron and photon activation analysis) as well as detection power in surface near regions of solids (ion beam techniques). Prominent features of NAMs are sensitivity, selectivity, multielement determination and linearity of the calibration function covering a concentration range of several orders of magnitude. Moreover, ion beam techniques allow depth profiling with nm-resolution in several cases while the ion microprobe additionally offers a lateral resolution in the micron-scale. As NAMs require expensive apparatus (nuclear reactor, accelerator in radioactive control areas) their availability is restricted to a small number of suitably equipped institutes. However, they are able to solve complex analytical tasks, take part in key comparisons and play an essential role in the certification of reference materials.

  18. Analytical Methods in Tracing Honey Authenticity.

    Science.gov (United States)

    Trifković, Jelena; Andrić, Filip; Ristivojević, Petar; Guzelmeric, Etil; Yesilada, Erdem

    2017-07-01

    Honey is a precious natural product that is marketed with a wide range of nutritional and medicinal properties. However, it is also a product subjected to frequent adulteration through mislabeling and mixing with cheaper and lower-quality honeys and various sugar syrups. In that sense, honey authentication regarding its genuine botanical and geographical origins, as well as the detection of any adulteration, is essential in order to protect consumer health and to avoid competition that could create a destabilized market. Various analytical techniques have been developed to detect adulterations in honey, including measuring the ratios of stable isotopes (mostly 13C/12C) and the use of different spectroscopic, chromatographic, and electrochemical methods. This review aims to provide a cross-section of contemporary analytical methods used for the determination of honey authenticity in order to help the scientific community engaged in the field of honey chemistry make appropriate choices and select the best applications that should lead to improvements in the detection and elimination of fraudulent practices in honey manufacturing.

  19. Radiochemical methods. Analytical chemistry by open learning

    Energy Technology Data Exchange (ETDEWEB)

    Geary, W.J.; James, A.M. (ed.)

    1986-01-01

    This book presents the analytical uses of radioactive isotopes within the context of radiochemistry as a whole. It is designed for scientists with relatively little background knowledge of the subject. Thus the initial emphasis is on developing the basic concepts of radioactive decay, particularly as they affect the potential usage of radioisotopes. Discussion of the properties of various types of radiation, and of factors such as half-life, is related to practical considerations such as counting and preparation methods, and handling/disposal problems. Practical aspects are then considered in more detail, and the various radioanalytical methods are outlined with particular reference to their applicability. The approach is 'user friendly' and the use of self assessment questions allows the reader to test his/her understanding of individual sections easily. For those who wish to develop their knowledge further, a reading list is provided.

  20. Determination of aluminum by four analytical methods

    International Nuclear Information System (INIS)

    Hanson, T.J.; Smetana, K.M.

    1975-11-01

    Four procedures have been developed for determining the aluminum concentration in basic matrices. Atomic Absorption Spectroscopy (AAS) was the routine method of analysis. Citrate was required to complex the aluminum and eliminate matrix effects. AAS was the least accurate of the four methods studied and was adversely affected by high aluminum concentrations. The Fluoride Electrode Method was the most accurate and precise of the four methods. A Gran's Plot determination was used to determine the end point and average standard recovery was 100% +- 2%. The Thermometric Titration Method was the fastest method for determining aluminum and could also determine hydroxide concentration at the same time. Standard recoveries were 100% +- 5%. The pH Electrode Method also measures aluminum and hydroxide content simultaneously, but is less accurate and more time consuming that the thermal titration. Samples were analyzed using all four methods and results were compared to determine the strengths and weaknesses of each. On the basis of these comparisons, conclusions were drawn concerning the application of each method to our laboratory needs

  1. Solution standards for quality control of nuclear-material analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.

    1981-01-01

    Analytical chemistry measurement control depends upon reliable solution standards. At the Savannah River Plant Control Laboratory over a thousand analytical measurements are made daily for process control, product specification, accountability, and nuclear safety. Large quantities of solution standards are required for a measurement quality control program covering the many different analytical chemistry methods. Savannah River Plant produced uranium, plutonium, neptunium, and americium metals or oxides are dissolved to prepare stock solutions for working or Quality Control Standards (QCS). Because extensive analytical effort is required to characterize or confirm these solutions, they are prepared in large quantities. These stock solutions are diluted and blended with different chemicals and/or each other to synthesize QCS that match the matrices of different process streams. The target uncertainty of a standard's reference value is 10% of the limit of error of the methods used for routine measurements. Standard Reference Materials from NBS are used according to special procedures to calibrate the methods used in measuring the uranium and plutonium standards so traceability can be established. Special precautions are required to minimize the effects of temperature, radiolysis, and evaporation. Standard reference values are periodically corrected to eliminate systematic errors caused by evaporation or decay products. Measurement control is achieved by requiring analysts to analyze a blind QCS each shift a measurement system is used on plant samples. Computer evaluation determines whether or not a measurement is within the +- 3 sigma control limits. Monthly evaluations of the QCS measurements are made to determine current bias correction factors for accountability measurements and detect significant changes in the bias and precision statistics. The evaluations are also used to plan activities for improving the reliability of the analytical chemistry measurements

  2. Analytical methods to assess nanoparticle toxicity.

    Science.gov (United States)

    Marquis, Bryce J; Love, Sara A; Braun, Katherine L; Haynes, Christy L

    2009-03-01

    During the past 20 years, improvements in nanoscale materials synthesis and characterization have given scientists great control over the fabrication of materials with features between 1 and 100 nm, unlocking many unique size-dependent properties and, thus, promising many new and/or improved technologies. Recent years have found the integration of such materials into commercial goods; a current estimate suggests there are over 800 nanoparticle-containing consumer products (The Project on Emerging Nanotechnologies Consumer Products Inventory, , accessed Oct. 2008), accounting for 147 billion USD in products in 2007 (Nanomaterials state of the market Q3 2008: stealth success, broad impact, Lux Research Inc., New York, NY, 2008). Despite this increase in the prevalence of engineered nanomaterials, there is little known about their potential impacts on environmental health and safety. The field of nanotoxicology has formed in response to this lack of information and resulted in a flurry of research studies. Nanotoxicology relies on many analytical methods for the characterization of nanomaterials as well as their impacts on in vitro and in vivo function. This review provides a critical overview of these techniques from the perspective of an analytical chemist, and is intended to be used as a reference for scientists interested in conducting nanotoxicological research as well as those interested in nanotoxicological assay development.

  3. Analytic Method for Computing Instrument Pointing Jitter

    Science.gov (United States)

    Bayard, David

    2003-01-01

    A new method of calculating the root-mean-square (rms) pointing jitter of a scientific instrument (e.g., a camera, radar antenna, or telescope) is introduced based on a state-space concept. In comparison with the prior method of calculating the rms pointing jitter, the present method involves significantly less computation. The rms pointing jitter of an instrument (the square root of the jitter variance shown in the figure) is an important physical quantity which impacts the design of the instrument, its actuators, controls, sensory components, and sensor- output-sampling circuitry. Using the Sirlin, San Martin, and Lucke definition of pointing jitter, the prior method of computing the rms pointing jitter involves a frequency-domain integral of a rational polynomial multiplied by a transcendental weighting function, necessitating the use of numerical-integration techniques. In practice, numerical integration complicates the problem of calculating the rms pointing error. In contrast, the state-space method provides exact analytic expressions that can be evaluated without numerical integration.

  4. Evolution of microbiological analytical methods for dairy industry needs

    Directory of Open Access Journals (Sweden)

    Daniele eSohier

    2014-02-01

    Full Text Available Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that PCR-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.

  5. Analytical method for Buddleja colorants in foods.

    Science.gov (United States)

    Aoki, H; Kuze, N; Ichi, T; Koda, T

    2001-04-01

    Buddleja yellow colorant derived from Buddleja officinalis Maxim. has recently been approved for use as a new kind of natural colorant for food additives in China. In order to distinguish Buddleja yellow colorant from other yellow colorants, two known phenylpropanoid glycosides, acteoside (= verbascoside) and poliumoside, were isolated from the colorant as marker substances for Buddleja yellow colorant. Poliumoside has not been detected in B. officinalis Maxim. previously. These phenylpropanoid glycosides were not detected in the fruits of Gardenia jasminoides Ellis or in the stamens of the flowers of Crocus sativus L., which also contain crocetin derivatives as coloring components, using a photodiode array and mass chromatograms. Thus, an analytical HPLC method was developed to distinguish foods that have been colored with yellow colorants containing crocetin derivatives, using phenylpropanoid glycosides as markers.

  6. Extended Standard Hough Transform for Analytical Line Recognition

    OpenAIRE

    Abdoulaye SERE; Oumarou SIE; Eric ANDRES

    2013-01-01

    This paper presents a new method which extends the Standard Hough Transform for the recognition of naive or standard line in a noisy picture. The proposed idea conserves the power of the Standard Hough Transform particularly a limited size of the parameter space and the recognition of vertical lines. The dual of a segment, and the dual of a pixel have been proposed to lead to a new definition of the preimage. Many alternatives of approximation could be established for the sinusoid curves of t...

  7. Hanford environmental analytical methods: Methods as of March 1990

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually

  8. Microgenetic Learning Analytics Methods: Workshop Report

    Science.gov (United States)

    Aghababyan, Ani; Martin, Taylor; Janisiewicz, Philip; Close, Kevin

    2016-01-01

    Learning analytics is an emerging discipline and, as such, benefits from new tools and methodological approaches. This work reviews and summarizes our workshop on microgenetic data analysis techniques using R, held at the second annual Learning Analytics Summer Institute in Cambridge, Massachusetts, on 30 June 2014. Specifically, this paper…

  9. Does leaf chemistry differentially affect breakdown in tropical vs temperate streams? Importance of standardized analytical techniques to measure leaf chemistry

    Science.gov (United States)

    Marcelo Ard& #243; n; Catherine M. Pringle; Susan L. Eggert

    2009-01-01

    Comparisons of the effects of leaf litter chemistry on leaf breakdown rates in tropical vs temperate streams are hindered by incompatibility among studies and across sites of analytical methods used to measure leaf chemistry. We used standardized analytical techniques to measure chemistry and breakdown rate of leaves from common riparian tree species at 2 sites, 1...

  10. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Science.gov (United States)

    2010-07-01

    ... § 425.03 Sulfide analytical methods and applicability. (a) The potassium ferricyanide titration method... ferricyanide titration method for the determination of sulfide in wastewaters discharged by plants operating in... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Sulfide analytical methods and...

  11. Comparison of analytical methods for calculation of wind loads

    Science.gov (United States)

    Minderman, Donald J.; Schultz, Larry L.

    1989-01-01

    The following analysis is a comparison of analytical methods for calculation of wind load pressures. The analytical methods specified in ASCE Paper No. 3269, ANSI A58.1-1982, the Standard Building Code, and the Uniform Building Code were analyzed using various hurricane speeds to determine the differences in the calculated results. The winds used for the analysis ranged from 100 mph to 125 mph and applied inland from the shoreline of a large open body of water (i.e., an enormous lake or the ocean) a distance of 1500 feet or ten times the height of the building or structure considered. For a building or structure less than or equal to 250 feet in height acted upon by a wind greater than or equal to 115 mph, it was determined that the method specified in ANSI A58.1-1982 calculates a larger wind load pressure than the other methods. For a building or structure between 250 feet and 500 feet tall acted upon by a wind rangind from 100 mph to 110 mph, there is no clear choice of which method to use; for these cases, factors that must be considered are the steady-state or peak wind velocity, the geographic location, the distance from a large open body of water, and the expected design life and its risk factor.

  12. An interactive website for analytical method comparison and bias estimation.

    Science.gov (United States)

    Bahar, Burak; Tuncel, Ayse F; Holmes, Earle W; Holmes, Daniel T

    2017-12-01

    Regulatory standards mandate laboratories to perform studies to ensure accuracy and reliability of their test results. Method comparison and bias estimation are important components of these studies. We developed an interactive website for evaluating the relative performance of two analytical methods using R programming language tools. The website can be accessed at https://bahar.shinyapps.io/method_compare/. The site has an easy-to-use interface that allows both copy-pasting and manual entry of data. It also allows selection of a regression model and creation of regression and difference plots. Available regression models include Ordinary Least Squares, Weighted-Ordinary Least Squares, Deming, Weighted-Deming, Passing-Bablok and Passing-Bablok for large datasets. The server processes the data and generates downloadable reports in PDF or HTML format. Our website provides clinical laboratories a practical way to assess the relative performance of two analytical methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Nonlinear ordinary differential equations analytical approximation and numerical methods

    CERN Document Server

    Hermann, Martin

    2016-01-01

    The book discusses the solutions to nonlinear ordinary differential equations (ODEs) using analytical and numerical approximation methods. Recently, analytical approximation methods have been largely used in solving linear and nonlinear lower-order ODEs. It also discusses using these methods to solve some strong nonlinear ODEs. There are two chapters devoted to solving nonlinear ODEs using numerical methods, as in practice high-dimensional systems of nonlinear ODEs that cannot be solved by analytical approximate methods are common. Moreover, it studies analytical and numerical techniques for the treatment of parameter-depending ODEs. The book explains various methods for solving nonlinear-oscillator and structural-system problems, including the energy balance method, harmonic balance method, amplitude frequency formulation, variational iteration method, homotopy perturbation method, iteration perturbation method, homotopy analysis method, simple and multiple shooting method, and the nonlinear stabilized march...

  14. A comparison of direct and indirect analytical methods of computing ...

    African Journals Online (AJOL)

    The first step in the analysis of gravity anomalies for mineral exploration is the extraction of residual gravity anomalies from the observed gravity anomalies. This can be achieved by graphical or analytical methods. Generally, direct and indirect analytical methods are considered better than graphical methods. Telford et al ...

  15. Recent developments in analytical detection methods for radiation processed foods

    International Nuclear Information System (INIS)

    Wu Jilan

    1993-01-01

    A short summary of the programmes of 'ADMIT' (FAO/IAEA) and the developments in analytical detection methods for radiation processed foods has been given. It is suggested that for promoting the commercialization of radiation processed foods and controlling its quality, one must pay more attention to the study of analytical detection methods of irradiated food

  16. An Analytical Procedure for the Equipercentile Method of Equating Tests.

    Science.gov (United States)

    Lindsay, Carl A.; Prichard, Mark A.

    Prior use of the equipercentile method of test equating was based on a graphic procedure which is tedious, subject to smoothing errors, and non-analytical. Recognition of the equipercentile method as a curve-fitting procedure for two cumulative percentage distributions leads to a proposed analytical solution to the problem through use of linear…

  17. Characterization and classification of external quality assessment schemes (EQA) according to objectives such as evaluation of method and participant bias and standard deviation. External Quality Assessment (EQA) Working Group A on Analytical Goals in Laboratory Medicine.

    Science.gov (United States)

    Libeer, J C; Baadenhuijsen, H; Fraser, C G; Petersen, P H; Ricós, C; Stöckl, D; Thienpont, L

    1996-08-01

    Within the scope of this paper, the Working Group has attempted to place external quality assessment (EQA) within the whole context of quality management in laboratory medicine. First, the objectives of EQA schemes are defined and current EQA schemes evaluated. In most schemes, the objectives are not defined a priori and do not allow the definition of the origin of unacceptable individual results from participants. There is an ongoing trend for making traditional EQA schemes more interesting for the participants. Analysis of the factors involved in analytical quality allow the definition of the essential analytical tasks of educational EQA schemes. Beside these quality control tasks, educational EQA also includes quality assurance elements. EQA today has not only an important role to play in the assessment of each participant's performance but also in the assessment of the method. Efficiency of the schemes and educational impact can be improved by appropriate scheme designs according to objectives. After this theoretical approach, some practical examples of problem related EQA designs are given.

  18. An Iteration Method Generating Analytical Solutions for Blasius Problem

    OpenAIRE

    Yun, Beong In

    2011-01-01

    We derive a new iteration method for finding solution of the generalized Blasius problem. This method results in the analytical series solutions which are consistent with the existing series solutions for some special cases.

  19. Learner Language Analytic Methods and Pedagogical Implications

    Science.gov (United States)

    Dyson, Bronwen

    2010-01-01

    Methods for analysing interlanguage have long aimed to capture learner language in its own right. By surveying the cognitive methods of Error Analysis, Obligatory Occasion Analysis and Frequency Analysis, this paper traces reformulations to attain this goal. The paper then focuses on Emergence Analysis, which fine-tunes learner language analysis…

  20. Finite analytic method for modeling variably saturated flows.

    Science.gov (United States)

    Zhang, Zaiyong; Wang, Wenke; Gong, Chengcheng; Yeh, Tian-Chyi Jim; Wang, Zhoufeng; Wang, Yu-Li; Chen, Li

    2018-04-15

    This paper develops a finite analytic method (FAM) for solving the two-dimensional Richards' equation. The FAM incorporates the analytic solution in local elements to formulate the algebraic representation of the partial differential equation of unsaturated flow so as to effectively control both numerical oscillation and dispersion. The FAM model is then verified using four examples, in which the numerical solutions are compared with analytical solutions, solutions from VSAFT2, and observational data from a field experiment. These numerical experiments show that the method is not only accurate but also efficient, when compared with other numerical methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Multicenter validation of the analytical accuracy of Salmonella PCR: towards an international standard

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Bunge, C.

    2003-01-01

    As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43 Salmo...... and is proposed as an international standard. This study addresses the increasing demand of quality assurance laboratories for standard diagnostic methods and presents findings that can facilitate the international comparison and exchange of epidemiological data.......As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43...... of selectivity by using 364 strains showed that the inclusivity was 99.6% and the exclusivity was 100% for the invA primer set. To indicate possible PCR inhibitors derived from the sample DNA, an internal amplification control (IAC), which was coamplified with the invA target gene, was constructed...

  2. Description of JNC's analytical method and its performance for FBR cores

    International Nuclear Information System (INIS)

    Ishikawa, M.

    2000-01-01

    The description of JNC's analytical method and its performance for FBR cores includes: an outline of JNC's Analytical System Compared with ERANOS; a standard data base for FBR Nuclear Design in JNC; JUPITER Critical Experiment; details of Analytical Method and Its Effects on JUPITER; performance of JNC Analytical System (effective multiplication factor k eff , control rod worth, and sodium void reactivity); design accuracy of a 600 MWe-class FBR Core. JNC developed a consistent analytical system for FBR core evaluation, based on JENDL library, f-table method, and three dimensional diffusion/transport theory, which includes comprehensive sensitivity tools to improve the prediction accuracy of core parameters. JNC system was verified by analysis of JUPITER critical experiment, and other facilities. Its performance can be judged quite satisfactory for FBR-core design work, though there is room for further improvement, such as more detailed treatment of cross-section resonance regions

  3. Analytical method for establishing indentation rolling resistance

    Science.gov (United States)

    Gładysiewicz, Lech; Konieczna, Martyna

    2018-01-01

    Belt conveyors are highly reliable machines able to work in special operating conditions. Harsh environment, long distance of transporting and great mass of transported martials are cause of high energy usage. That is why research in the field of belt conveyor transportation nowadays focuses on reducing the power consumption without lowering their efficiency. In this paper, previous methods for testing rolling resistance are described, and new method designed by authors was presented. New method of testing rolling resistance is quite simple and inexpensive. Moreover it allows to conduct the experimental tests of the impact of different parameters on the value of indentation rolling resistance such as core design, cover thickness, ambient temperature, idler travel frequency, or load value as well. Finally results of tests of relationship between rolling resistance and idler travel frequency and between rolling resistance and idler travel speed was presented.

  4. Preparation of standard hair material and development of analytical methodology

    International Nuclear Information System (INIS)

    Gangadharan, S.; Walvekar, A.P.; Ali, M.M.; Thantry, S.S.; Verma, R.; Devi, R.

    1995-01-01

    The concept of the use of human scalp hair as a first level indicator of exposure to inorganic pollutants has been established by us earlier. Efforts towards the preparation of a hair reference material are described. The analytical approaches for the determination of total mercury by cold vapour AAS and INAA and of methylmercury by extraction combined with gas chromatography coupled to an ECD are summarized with results on some of the samples analyzed, including the stability of values over a period of time of storage. (author)

  5. ANALYTICAL METHODS FOR CALCULATING FAN AERODYNAMICS

    Directory of Open Access Journals (Sweden)

    Jan Dostal

    2015-12-01

    Full Text Available This paper presents results obtained between 2010 and 2014 in the field of fan aerodynamics at the Department of Composite Technology at the VZLÚ aerospace research and experimental institute in Prague – Letnany. The need for rapid and accurate methods for the preliminary design of blade machinery led to the creation of a mathematical model based on the basic laws of turbomachine aerodynamics. The mathematical model, the derivation of which is briefly described below, has been encoded in a computer programme, which enables the theoretical characteristics of a fan of the designed geometry to be determined rapidly. The validity of the mathematical model is assessed continuously by measuring model fans in the measuring unit, which was developed and manufactured specifically for this purpose. The paper also presents a comparison between measured characteristics and characteristics determined by the mathematical model as the basis for a discussion on possible causes of measured deviations and calculation deviations.

  6. Application of Statistical Methods to Activation Analytical Results near the Limit of Detection

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Wanscher, B.

    1978-01-01

    Reporting actual numbers instead of upper limits for analytical results at or below the detection limit may produce reliable data when these numbers are subjected to appropriate statistical processing. Particularly in radiometric methods, such as activation analysis, where individual standard...... deviations of analytical results may be estimated, improved discrimination may be based on the Analysis of Precision. Actual experimental results from a study of the concentrations of arsenic in human skin demonstrate the power of this principle....

  7. Standardizing Physiologic Assessment Data to Enable Big Data Analytics.

    Science.gov (United States)

    Matney, Susan A; Settergren, Theresa Tess; Carrington, Jane M; Richesson, Rachel L; Sheide, Amy; Westra, Bonnie L

    2016-07-18

    Disparate data must be represented in a common format to enable comparison across multiple institutions and facilitate big data science. Nursing assessments represent a rich source of information. However, a lack of agreement regarding essential concepts and standardized terminology prevent their use for big data science in the current state. The purpose of this study was to align a minimum set of physiological nursing assessment data elements with national standardized coding systems. Six institutions shared their 100 most common electronic health record nursing assessment data elements. From these, a set of distinct elements was mapped to nationally recognized Logical Observations Identifiers Names and Codes (LOINC®) and Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT®) standards. We identified 137 observation names (55% new to LOINC), and 348 observation values (20% new to SNOMED CT) organized into 16 panels (72% new LOINC). This reference set can support the exchange of nursing information, facilitate multi-site research, and provide a framework for nursing data analysis. © The Author(s) 2016.

  8. Comparative Analytical Methods for the Measurment of Chlorine Dioxide

    OpenAIRE

    Desai, Unmesh Jeetendra

    2002-01-01

    Four commercially available methods used for the analysis of low-level Chlorine Dioxide (ClO2) concentrations in drinking water were evaluated for accuracy and precision and ranked according to cost, efficiency and ease of the methods under several conditions that might be encountered at water treatment plants. The different analytical methods included: 1.The DPD (N, N-diethyl-p-phenylenediamine) method 2.Lissamine Green B (LGB) wet-chemical method 3.Palintest® kit LGB 4.A...

  9. Creatinine Assay Attainment of Analytical Performance Goals Following Implementation of IDMS Standardization

    Directory of Open Access Journals (Sweden)

    Elizabeth Sunmin Lee

    2017-02-01

    Full Text Available Background: The international initiative to standardize creatinine (Cr assays by tracing reference materials to Isotope Dilution Mass Spectrometry (IDMS assigned values was implemented to reduce interlaboratory variability and improve assay accuracy. Objective: The aims of this study were to examine whether IDMS standardization has improved Cr assay accuracy (bias, interlaboratory variability (precision, total error (TE, and attainment of recommended analytical performance goals. Methods: External Quality Assessment (EQA data (n = 66 challenge vials from Ontario, Canada, were analyzed. The bias, precision, TE, and the number of EQA challenge vials meeting performance goals were determined by assay manufacturer before (n = 32 and after (n = 34 IDMS implementation. Results: The challenge vials with the worst bias and precision were spiked with known common interfering substances (glucose and bilirubin. IDMS standardization improved assay bias (10.4%-1.6%, P < .001, but precision remained unchanged (5.0%-4.7%, P = .5 with performance goals not consistently being met. Precision and TE goals based on biologic variation were attained by only 29% to 69% and 32% to 62% of challenge vials. Conclusions: While IDMS standardization has improved Cr assay accuracy and thus reduced TE, significant interlaboratory variability remains. Contemporary Cr assays do not currently meet the standards required to allow for accurate and consistent estimated glomerular filtration rate assessment and chronic kidney disease diagnosis across laboratories. Further improvements in Cr assay performance are needed.

  10. Development of quality-by-design analytical methods.

    Science.gov (United States)

    Vogt, Frederick G; Kord, Alireza S

    2011-03-01

    Quality-by-design (QbD) is a systematic approach to drug development, which begins with predefined objectives, and uses science and risk management approaches to gain product and process understanding and ultimately process control. The concept of QbD can be extended to analytical methods. QbD mandates the definition of a goal for the method, and emphasizes thorough evaluation and scouting of alternative methods in a systematic way to obtain optimal method performance. Candidate methods are then carefully assessed in a structured manner for risks, and are challenged to determine if robustness and ruggedness criteria are satisfied. As a result of these studies, the method performance can be understood and improved if necessary, and a control strategy can be defined to manage risk and ensure the method performs as desired when validated and deployed. In this review, the current state of analytical QbD in the industry is detailed with examples of the application of analytical QbD principles to a range of analytical methods, including high-performance liquid chromatography, Karl Fischer titration for moisture content, vibrational spectroscopy for chemical identification, quantitative color measurement, and trace analysis for genotoxic impurities. Copyright © 2010 Wiley-Liss, Inc.

  11. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  12. Analytic methods for field induced tunneling in quantum wells with ...

    Indian Academy of Sciences (India)

    Electric field induced tunneling is studied in three different types of quantum wells by solving time-independent effective mass equation in analytic methods based on three different Airy function approaches. Comparison of different Airy function methods indicates that they are identical and connected to each other by the ...

  13. A simple regularization method for stable analytic continuation

    Science.gov (United States)

    Fu, Chu-Li; Dou, Fang-Fang; Feng, Xiao-Li; Qian, Zhi

    2008-12-01

    The problems of analytic continuation are frequently encountered in many practical applications. These problems are well known to be severely ill-posed and therefore several regularization methods have been suggested for solving them. In this paper we consider the problem of analytic continuation of the analytic function f(z) = f(x + iy) on a strip domain \\Omega=\\{z=x+iy\\in {\\bb C}|x\\in{\\bb R},|y|\\leq y_0\\} , where the data are given only on the line y = 0. We use a very simple and convenient method—the Fourier regularization method to solve this problem. Some sharp error estimates between the exact solution and its approximation are given and numerical examples show the method works effectively. The project is supported by the National Natural Science Foundation of China (Nos. 10671085, 10571079 and 10726017).

  14. Teaching Analytical Method Transfer through Developing and Validating Then Transferring Dissolution Testing Methods for Pharmaceuticals

    Science.gov (United States)

    Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette

    2017-01-01

    Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…

  15. Rigid inclusions-Comparison between analytical and numerical methods

    International Nuclear Information System (INIS)

    Gomez Perez, R.; Melentijevic, S.

    2014-01-01

    This paper compares different analytical methods for analysis of rigid inclusions with finite element modeling. First of all, the load transfer in the distribution layer is analyzed for its different thicknesses and different inclusion grids to define the range between results obtained by analytical and numerical methods. The interaction between the soft soil and the inclusion in the estimation of settlements is studied as well. Considering different stiffness of the soft soil, settlements obtained analytical and numerically are compared. The influence of the soft soil modulus of elasticity on the neutral point depth was also performed by finite elements. This depth has a great importance for the definition of the total length of rigid inclusion. (Author)

  16. SPANDOM - source projection analytic nodal discrete ordinates method

    International Nuclear Information System (INIS)

    Kim, Tae Hyeong; Cho, Nam Zin

    1994-01-01

    We describe a new discrete ordinates nodal method for the two-dimensional transport equation. We solve the discrete ordinates equation analytically after the source term is projected and represented in polynomials. The method is applied to two fast reactor benchmark problems and compared with the TWOHEX code. The results indicate that the present method accurately predicts not only multiplication factor but also flux distribution

  17. Analytical chemistry in semiconductor manufacturing: Techniques, role of nuclear methods and need for quality control

    International Nuclear Information System (INIS)

    1989-06-01

    This report is the result of a consultants meeting held in Gaithersburg, USA, 2-3 October 1987. The meeting was hosted by the National Bureau of Standards and Technology, and it was attended by 18 participants from Denmark, Finland, India, Japan, Norway, People's Republic of China and the USA. The purpose of the meeting was to assess the present status of analytical chemistry in semiconductor manufacturing, the role of nuclear analytical methods and the need for internationally organized quality control of the chemical analysis. The report contains the three presentations in full and a summary report of the discussions. Thus, it gives an overview of the need of analytical chemistry in manufacturing of silicon based devices, the use of nuclear analytical methods, and discusses the need for quality control. Refs, figs and tabs

  18. Using Learning Analytics to Enhance Student Learning in Online Courses Based on Quality Matters Standards

    Science.gov (United States)

    Martin, Florence; Ndoye, Abdou; Wilkins, Patricia

    2016-01-01

    Quality Matters is recognized as a rigorous set of standards that guide the designer or instructor to design quality online courses. We explore how Quality Matters standards guide the identification and analysis of learning analytics data to monitor and improve online learning. Descriptive data were collected for frequency of use, time spent, and…

  19. Literature Review on Processing and Analytical Methods for ...

    Science.gov (United States)

    Report The purpose of this report was to survey the open literature to determine the current state of the science regarding the processing and analytical methods currently available for recovery of F. tularensis from water and soil matrices, and to determine what gaps remain in the collective knowledge concerning F. tularensis identification from environmental samples.

  20. Frontier in nanoscale flows fractional calculus and analytical methods

    CERN Document Server

    Lewis, Roland; Liu, Hong-yan

    2014-01-01

    This ebook covers the basic properties of nanoscale flows, and various analytical and numerical methods for nanoscale flows and environmental flows. This ebook is a good reference not only for audience of the journal, but also for various communities in mathematics, nanotechnology and environmental science.

  1. An Analytical Method For The Solution Of Reactor Dynamic Equations

    African Journals Online (AJOL)

    Nigeria Journal of Pure and Applied Physics ... One of the challenges of modelling nuclear reactor dynamics on microcomputers is that of finding robust techniques which guarantee the required level of accuracy and at ... In this paper, an analytical method for the solution of nuclear reactor dynamic equations is presented.

  2. From basic survival analytic theory to a non-standard application

    CERN Document Server

    Zimmermann, Georg

    2017-01-01

    Georg Zimmermann provides a mathematically rigorous treatment of basic survival analytic methods. His emphasis is also placed on various questions and problems, especially with regard to life expectancy calculations arising from a particular real-life dataset on patients with epilepsy. The author shows both the step-by-step analyses of that dataset and the theory the analyses are based on. He demonstrates that one may face serious and sometimes unexpected problems, even when conducting very basic analyses. Moreover, the reader learns that a practically relevant research question may look rather simple at first sight. Nevertheless, compared to standard textbooks, a more detailed account of the theory underlying life expectancy calculations is needed in order to provide a mathematically rigorous framework. Contents Regression Models for Survival Data Model Checking Procedures Life Expectancy Target Groups Researchers, lecturers, and students in the fields of mathematics and statistics Academics and experts work...

  3. Analytical standards production for the analysis of pomegranate anthocyanins by HPLC

    Directory of Open Access Journals (Sweden)

    Manuela Cristina Pessanha de Araújo Santiago

    2014-03-01

    Full Text Available Pomegranate (Punica granatum L. is a fruit with a long medicinal history, especially due to its phenolic compounds content, such as the anthocyanins, which are reported as one of the most important natural antioxidants. The analysis of the anthocyanins by high performance liquid chromatography (HPLC can be considered as an important tool to evaluate the quality of pomegranate juice. For research laboratories the major challenge in using HPLC for quantitative analyses is the acquisition of high purity analytical standards, since these are expensive and in some cases not even commercially available. The aim of this study was to obtain analytical standards for the qualitative and quantitative analysis of the anthocyanins from pomegranate. Five vegetable matrices (pomegranate flower, jambolan, jabuticaba, blackberry and strawberry fruits were used to isolate each of the six anthocyanins present in pomegranate fruit, using an analytical HPLC scale with non-destructive detection, it being possible to subsequently use them as analytical standards. Furthermore, their identities were confirmed by high resolution mass spectrometry. The proposed procedure showed that it is possible to obtain analytical standards of anthocyanins with a high purity grade (98.0 to 99.9% from natural sources, which was proved to be an economic strategy for the production of standards by laboratories according to their research requirements.

  4. Prediction of polymer flooding performance using an analytical method

    International Nuclear Information System (INIS)

    Tan Czek Hoong; Mariyamni Awang; Foo Kok Wai

    2001-01-01

    The study investigated the applicability of an analytical method developed by El-Khatib in polymer flooding. Results from a simulator UTCHEM and experiments were compared with the El-Khatib prediction method. In general, by assuming a constant viscosity polymer injection, the method gave much higher recovery values than the simulation runs and the experiments. A modification of the method gave better correlation, albeit only oil production. Investigation is continuing on modifying the method so that a better overall fit can be obtained for polymer flooding. (Author)

  5. Use of scientometrics to assess nuclear and other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs.

  6. Use of scientometrics to assess nuclear and other analytical methods

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs

  7. Long-Term Prediction of Satellite Orbit Using Analytical Method

    Directory of Open Access Journals (Sweden)

    Jae-Cheol Yoon

    1997-12-01

    Full Text Available A long-term prediction algorithm of geostationary orbit was developed using the analytical method. The perturbation force models include geopotential upto fifth order and degree and luni-solar gravitation, and solar radiation pressure. All of the perturbation effects were analyzed by secular variations, short-period variations, and long-period variations for equinoctial elements such as the semi-major axis, eccentricity vector, inclination vector, and mean longitude of the satellite. Result of the analytical orbit propagator was compared with that of the cowell orbit propagator for the KOREASAT. The comparison indicated that the analytical solution could predict the semi-major axis with an accuarcy of better than ~35meters over a period of 3 month.

  8. Theological Predication, Doctrinal Location, and Method in Analytic Theology

    Directory of Open Access Journals (Sweden)

    Peterson Ryan S.

    2017-09-01

    Full Text Available Theological method is situated properly in relation to a range of doctrinal commitments, especially commitments located in the doctrines of God, creation, and theological anthropology. In this article, I use Thomas Aquinas’s account of theological predication to illustrate this doctrinal and methodological interconnection. Then, I describe the methodological commitments of analytic theology as they have been articulated by its advocates and argue that analytic theology should embrace an explicitly theological methodology. This requires taking seriously the proper ends of theology and the varied means used by theologians in the Christian theological tradition. I argue that analytic theologians should nurture attentiveness to theology’s chief end (the visio Dei and the corresponding goals of faithful worship and personal formation, the doctrinal order in which specific doctrinal questions find their proper context and location (beginning from and ending with the doctrine of God, and the practices that facilitate good theological judgment-making (prayer and contemplation.

  9. Analytical Methods of Decoupling the Automotive Engine Torque Roll Axis

    Science.gov (United States)

    JEONG, TAESEOK; SINGH, RAJENDRA

    2000-06-01

    This paper analytically examines the multi-dimensional mounting schemes of an automotive engine-gearbox system when excited by oscillating torques. In particular, the issue of torque roll axis decoupling is analyzed in significant detail since it is poorly understood. New dynamic decoupling axioms are presented an d compared with the conventional elastic axis mounting and focalization methods. A linear time-invariant system assumption is made in addition to a proportionally damped system. Only rigid-body modes of the powertrain are considered and the chassis elements are assumed to be rigid. Several simplified physical systems are considered and new closed-form solutions for symmetric and asymmetric engine-mounting systems are developed. These clearly explain the design concepts for the 4-point mounting scheme. Our analytical solutions match with the existing design formulations that are only applicable to symmetric geometries. Spectra for all six rigid-body motions are predicted using the alternate decoupling methods and the closed-form solutions are verified. Also, our method is validated by comparing modal solutions with prior experimental and analytical studies. Parametric design studies are carried out to illustrate the methodology. Chief contributions of this research include the development of new or refined analytical models and closed-form solutions along with improved design strategies for the torque roll axis decoupling.

  10. Sampling and analytical methods for atmospheric reduced sulphur compounds

    OpenAIRE

    Cruz, Lícia P. S.; Campos, Vânia P.

    2008-01-01

    This work presents a review of sampling and analytical methods that can be applied to atmospheric traces of reduced sulphur compounds (RSC) in the atmosphere. Sampling methodology involving discontinuous methods with preconcentration is mostly used. For the most part, adsorption on solids and cryogenic capture are applied as a procedure. The analysis of these compounds has been done mainly by gas chromatography with FPD, fluorescence and spectrophotometry. Advantages and disadvantages of the ...

  11. Current analytical methods for plant auxin quantification--A review.

    Science.gov (United States)

    Porfírio, Sara; Gomes da Silva, Marco D R; Peixe, Augusto; Cabrita, Maria J; Azadi, Parastoo

    2016-01-01

    Plant hormones, and especially auxins, are low molecular weight compounds highly involved in the control of plant growth and development. Auxins are also broadly used in horticulture, as part of vegetative plant propagation protocols, allowing the cloning of genotypes of interest. Over the years, large efforts have been put in the development of more sensitive and precise methods of analysis and quantification of plant hormone levels in plant tissues. Although analytical techniques have evolved, and new methods have been implemented, sample preparation is still the limiting step of auxin analysis. In this review, the current methods of auxin analysis are discussed. Sample preparation procedures, including extraction, purification and derivatization, are reviewed and compared. The different analytical techniques, ranging from chromatographic and mass spectrometry methods to immunoassays and electrokinetic methods, as well as other types of detection are also discussed. Considering that auxin analysis mirrors the evolution in analytical chemistry, the number of publications describing new and/or improved methods is always increasing and we considered appropriate to update the available information. For that reason, this article aims to review the current advances in auxin analysis, and thus only reports from the past 15 years will be covered. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Standardization guide for construction and use of MORT-type analytic trees

    Energy Technology Data Exchange (ETDEWEB)

    Buys, J.R.

    1992-02-01

    Since the introduction of MORT (Management Oversight and Risk Tree) technology as a tool for evaluating the success or failure of safety management systems, there has been a proliferation of analytic trees throughout US Department of Energy (DOE) and its contractor organizations. Standard fault tree'' symbols have generally been used in logic diagram or tree construction, but new or revised symbols have also been adopted by various analysts. Additionally, a variety of numbering systems have been used for event identification. The consequent lack of standardization has caused some difficulties in interpreting the trees and following their logic. This guide seeks to correct this problem by providing a standardized system for construction and use of analytic trees. Future publications of the DOE System Safety Development Center (SSDC) will adhere to this guide. It is recommended that other DOE organizations and contractors also adopt this system to achieve intra-DOE uniformity in analytic tree construction.

  13. Analytical Methods for the Quantification of Histamine and Histamine Metabolites.

    Science.gov (United States)

    Bähre, Heike; Kaever, Volkhard

    2017-01-01

    The endogenous metabolite histamine (HA) is synthesized in various mammalian cells but can also be ingested from exogenous sources. It is involved in a plethora of physiological and pathophysiological processes. So far, four different HA receptors (H 1 R-H 4 R) have been described and numerous HAR antagonists have been developed. Contemporary investigations regarding the various roles of HA and its main metabolites have been hampered by the lack of highly specific and sensitive analytic methods for all of these analytes. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) is the method of choice for identification and sensitive quantification of many low-molecular weight endogenous metabolites. In this chapter, different methodological aspects of HA quantification as well as recommendations for LC-MS/MS methods suitable for analysis of HA and its main metabolites are summarized.

  14. Validation of analytical methods based on accuracy profiles.

    Science.gov (United States)

    Feinberg, Max

    2007-07-27

    Validation is a very living field in analytical chemistry as illustrated by the numerous publications addressing this topic. But, there is some ambiguity in this concept and the abundant vocabulary often does not help the analytical chemist. This paper presents a new method based on the fitness-for-purpose approach of the validation. It consists in building a graphical decision-making tool, called the accuracy profile. Using measurements collected under reproducibility or intermediate precision condition, it allows computing an interval where a known proportion of future measurements will be located. When comparing this interval to an acceptability interval defined by the result end-user it is possible to simply decide whether a method is valid or not. The fundamentals of this method are presented starting from an accepted definition of validation. An example of application illustrates how validation can be experimentally organized and conclusion made.

  15. Developments and retrospectives in Lie theory geometric and analytic methods

    CERN Document Server

    Penkov, Ivan; Wolf, Joseph

    2014-01-01

    This volume reviews and updates a prominent series of workshops in representation/Lie theory, and reflects the widespread influence of those  workshops in such areas as harmonic analysis, representation theory, differential geometry, algebraic geometry, and mathematical physics.  Many of the contributors have had leading roles in both the classical and modern developments of Lie theory and its applications. This Work, entitled Developments and Retrospectives in Lie Theory, and comprising 26 articles, is organized in two volumes: Algebraic Methods and Geometric and Analytic Methods. This is the Geometric and Analytic Methods volume. The Lie Theory Workshop series, founded by Joe Wolf and Ivan Penkov and joined shortly thereafter by Geoff Mason, has been running for over two decades. Travel to the workshops has usually been supported by the NSF, and local universities have provided hospitality. The workshop talks have been seminal in describing new perspectives in the field covering broad areas of current re...

  16. Nuclear and nuclear related analytical methods applied in environmental research

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Gheboianu, Anca; Bancuta, Iulian; Cimpoca, G. V; Stihi, Claudia; Radulescu, Cristiana; Oros Calin; Frontasyeva, Marina; Petre, Marian; Dulama, Ioana; Vlaicu, G.

    2010-01-01

    Nuclear Analytical Methods can be used for research activities on environmental studies like water quality assessment, pesticide residues, global climatic change (transboundary), pollution and remediation. Heavy metal pollution is a problem associated with areas of intensive industrial activity. In this work the moss bio monitoring technique was employed to study the atmospheric deposition in Dambovita County Romania. Also, there were used complementary nuclear and atomic analytical methods: Neutron Activation Analysis (NAA), Atomic Absorption Spectrometry (AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). These high sensitivity analysis methods were used to determine the chemical composition of some samples of mosses placed in different areas with different pollution industrial sources. The concentrations of Cr, Fe, Mn, Ni and Zn were determined. The concentration of Fe from the same samples was determined using all these methods and we obtained a very good agreement, in statistical limits, which demonstrate the capability of these analytical methods to be applied on a large spectrum of environmental samples with the same results. (authors)

  17. FORECASTING PILE SETTLEMENT ON CLAYSTONE USING NUMERICAL AND ANALYTICAL METHODS

    Directory of Open Access Journals (Sweden)

    Ponomarev Andrey Budimirovich

    2016-06-01

    Full Text Available In the article the problem of designing pile foundations on claystones is reviewed. The purpose of this paper is comparative analysis of the analytical and numerical methods for forecasting the settlement of piles on claystones. The following tasks were solved during the study: 1 The existing researches of pile settlement are analyzed; 2 The characteristics of experimental studies and the parameters for numerical modeling are presented, methods of field research of single piles’ operation are described; 3 Calculation of single pile settlement is performed using numerical methods in the software package Plaxis 2D and analytical method according to the requirements SP 24.13330.2011; 4 Experimental data is compared with the results of analytical and numerical calculations; 5 Basing on these results recommendations for forecasting pile settlement on claystone are presented. Much attention is paid to the calculation of pile settlement considering the impacted areas in ground space beside pile and the comparison with the results of field experiments. Basing on the obtained results, for the prediction of settlement of single pile on claystone the authors recommend using the analytical method considered in SP 24.13330.2011 with account for the impacted areas in ground space beside driven pile. In the case of forecasting the settlement of single pile on claystone by numerical methods in Plaxis 2D the authors recommend using the Hardening Soil model considering the impacted areas in ground space beside the driven pile. The analyses of the results and calculations are presented for examination and verification; therefore it is necessary to continue the research work of deep foundation at another experimental sites to improve the reliability of the calculation of pile foundation settlement. The work is of great interest for geotechnical engineers engaged in research, design and construction of pile foundations.

  18. Customizing computational methods for visual analytics with big data.

    Science.gov (United States)

    Choo, Jaegul; Park, Haesun

    2013-01-01

    The volume of available data has been growing exponentially, increasing data problem's complexity and obscurity. In response, visual analytics (VA) has gained attention, yet its solutions haven't scaled well for big data. Computational methods can improve VA's scalability by giving users compact, meaningful information about the input data. However, the significant computation time these methods require hinders real-time interactive visualization of big data. By addressing crucial discrepancies between these methods and VA regarding precision and convergence, researchers have proposed ways to customize them for VA. These approaches, which include low-precision computation and iteration-level interactive visualization, ensure real-time interactive VA for big data.

  19. OVERVIEW OF VALIDATION, BASIC CONCEPTS AND ANALYTICAL METHOD PROCESS VALIDATION

    OpenAIRE

    Indu Gurram* , M.V.S.Kavitha, M.V.Nagabhushnam, Brahmaiah Bonthagara, D.Nagarjuna Reddy

    2017-01-01

    Quality is the primordial intention to any industry and its products manufactured. Multiple views on obtaining such quality are the current interest in the pharmaceutical industry. Validation is the art of designing and practicing the designed steps alongside with the documentation. Validation and quality assurance will go hand in hand, ensuring the through quality for the products. When analytical method is utilized to generate results about the characteristics of drug related samples it is ...

  20. Nanometrology, Standardization and Regulation of Nanomaterials in Brazil: A Proposal for an Analytical-Prospective Model

    Directory of Open Access Journals (Sweden)

    Ana Rusmerg Giménez Ledesma

    2013-05-01

    Full Text Available The main objective of this paper is to propose an analytical-prospective model as a tool to support decision-making processes concerning metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world. In the context of nanotechnology development in Brazil, the motivation for carrying out this research was to identify potential benefits of metrology, standardization and regulation of nanomaterials production, from the perspective of future adoption of the model by the main stakeholders of development of these areas in Brazil. The main results can be summarized as follows: (i an overview of international studies on metrology, standardization and regulation of nanomaterials, and nanoparticles, in special; (ii the analytical-prospective model; and (iii the survey questionnaire and the roadmapping tool for metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world.

  1. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  2. An Analytical Method for the Abel Inversion of Asymmetrical Gaussian Profiles

    International Nuclear Information System (INIS)

    Xu Guosheng; Wan Baonian

    2007-01-01

    An analytical algorithm for fast calculation of the Abel inversion for density profile measurement in tokamak is developed. Based upon the assumptions that the particle source is negligibly small in the plasma core region, density profiles can be approximated by an asymmetrical Gaussian distribution controlled only by one parameter V 0 /D and V 0 /D is constant along the radial direction, the analytical algorithm is presented and examined against a testing profile. The validity is confirmed by benchmark with the standard Abel inversion method and the theoretical profile. The scope of application as well as the error analysis is also discussed in detail

  3. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, Chris; Little, Mike; Huang, Thomas; Jacob, Joseph; Yang, Phil; Kuo, Kwo-Sen

    2016-01-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based file systems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  4. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, C.; Little, M. M.; Huang, T.; Jacob, J. C.; Yang, C. P.; Kuo, K. S.

    2016-12-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based filesystems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  5. Analytical method to determine flexoelectric coupling coefficient at nanoscale

    Science.gov (United States)

    Zhou, Hao; Pei, Yongmao; Hong, Jiawang; Fang, Daining

    2016-03-01

    Flexoelectricity is defined as the coupling between the strain gradient and polarization, which is expected to be remarkable at nanoscale. However, measuring the flexoelectricity at nanoscale is challenging. In the present work, an analytical method for measuring the flexoelectric coupling coefficient based on nanocompression technique is proposed. It is found that the flexoelectricity can induce stiffness softening of the dielectric nano-cone-frustum. This phenomenon becomes more significant when the sample size decreases or the half cone angle increases. This method avoids measuring the electric polarization or current at nanoscale with dynamical loading, which can be beneficial to the flexoelectric measurement at nanoscale and design of flexoelectric nanodevices.

  6. Analytical method used for intermediate products in continuous distillation of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z.L.; Jia, M.; Wang, L.J.; Deng, Y.X.

    1981-01-01

    During distillation of furfural, analysis of main components in the crude furfural condensate and intermediate products is very important. Since furfural and methylfurfural are homologous and both furfural and acetone contain a carbonyl group, components in the sample must be separated before analysis. An improved analytical method has been studied, the accuracy and precision of which would meet the requirement of industrial standards. The analytical procedure was provided as follows: to determine the furfural content with gravimetric method of barbituric acid; to determine the methanol content with dichromate method after precipitating furfural and acetone, and distilling the liquid for analysis; and to determine the methylfurfural content with bromide-bromate method, which can be used only in the sample containing higher content of methylfurfural. For the sample in low content, the gas-liquid chromatographic method can be used. 7 references.

  7. Analytical Methods for Mycotoxin Detection in Southeast Asian Nations (ASEAN).

    Science.gov (United States)

    Lim, Chee Wei; Chung, Gerald; Chan, Sheot Harn

    2017-10-03

    Aflatoxins B 1 (AFB 1 ) and B₂ (AFB₂) and G 1 and G₂ remain the top mycotoxins routinely analyzed and monitored by Association of Southeast Asian Nations (ASEAN) national laboratories primarily for food safety regulation in the major food commodities, nuts and spices. LC tandem fluorescence detection (LC–fluorescence) represents a current mainstream analytical method, with a progressive migration to a primary method by LC tandem MS (MS/MS) for the next half decade. Annual proficiency testing (PT) is conducted by ASEAN Food Reference Laboratories (AFRLs) for mycotoxin testing as part of capability building in national laboratories, with the scope of PT materials spanning from naturally mycotoxin-contaminated spices and nuts in the early 2010s to the recent contamination of corn flour in 2017 for total aflatoxin assay development. The merits of the mainstream LC–fluorescence method are witnessed by a significant improvement ( P < 0.05) in PT z -score passing rates (≤2) from 11.8 to 79.2% for AFB 1 , 23.5 to 83.3% for AFB₂, and 23.5 to 79.2% for total aflatoxins in the last 5 years. This paper discusses the journey of ASEAN national laboratories in analytical testing through AFRLs, and the progressive collective adoption of a multimycotoxin LC-MS/MS method aided by an isotopic dilution assay as a future primary method for safer food commodities.

  8. Development of analytical methods for the determination of trace elements in sediment with Neutron ActivAtion method (NAA) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Nam, Sang Ho; Kim, Jae Jin; Chung, Yong Sam; Kim, Sun Ha

    2005-01-01

    The analytical methods for the determination of major elements (Al, Ca, K, Fe, Mg) in sediment have been investigated with ICP-MS. The analytical results of major elements with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA. NAA were a little superior to ICP-MS for the determination of major elements in sediment, and NAA is a non-destructive analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) in sediment have been also studied with ICP-MS. The analytical results by standard calibration with ICP-MS were not accurate due to matrix interferences. Thus, internal standard method was applied, then the analytical results for minor element with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments

  9. Determination of carbendazim, thiabendazole and fuberidazole using a net analyte signal-based method.

    Science.gov (United States)

    Martínez Galera, M; Picón Zamora, D; Martínez Vidal, J L; Garrido Frenich, A; Espinosa-Mansilla, A; Muñoz de la Peña, A; Salinas López, F

    2003-05-01

    The net analyte signal (NAS)-based method HLA/GO, modification of the original hybrid linear analysis (HLA) method, has been used to determine carbendazim, fuberidazole and thiabendazole in water samples. This approach was used after a solid-phase extraction (SPE) step, using the native fluorescence emission spectra of real samples, previously standardized by piecewise direct standardization (PDS). The results obtained show that the modification of HLA performs in a similar way that partial least-squares method (PLS-1). The NAS concept was also used to calculate multivariate analytical figures of merit such as limit of detection, selectivity, sensitivity and analytical sensitivity (gamma(-1)). With this purpose, blanks of methanol and ternary mixtures, with the target analyte at low concentration and the other two ranging according to the calibration matrix, were used, with different results. Detection limits calculated in the last way are more realistic and show the influence of the other components in the sample. Selectivity for carbendazim is higher than the corresponding values for fuberidazole and thiabendazole, whereas sensitivity, as well as the values obtained for their detection limits, are lower for carbendazim, followed by thiabendazole and fuberidazole. Results obtained by modification of HLA vary in the same way that the ones obtained by PLS-1.

  10. Comparison of Three Analytical Methods for Separation of Mineral and Chelated Fraction from an Adulterated Zn-EDTA Fertilizer

    International Nuclear Information System (INIS)

    Khan, M.S.; Qazi, M.A.; Khan, N.A.; Mian, S.M.; Ahmed, N.; Ahmed, N.

    2013-01-01

    Summary: Different analytical procedures are being employed in the world to quantify the chelated portion in a Zn-EDTA fertilizer. Agriculture Department, Government of the Punjab is following Shahid's analytical method in this regard. This method is based on Ion-chromatography (IC) that separates the mineral zinc (Zn) from an adulterated Zn-EDTA fertilizer sample i.e. mixture of mineral and chelated Zn fractions. To find out its effectiveness and suitability, this comparative study was carried out by analyzing adulterated, non-adulterated Zn-EDTA standard and Zn-EDTA samples taken from market in thrice following three methods namely Shahid's (IC) analytical method, Atomic Absorption Spectrophotometric (AAS) method based on the principle of precipitating the mineral Zn fraction at high pH value by using alkali solution of suitable concentration and analysis of filtrate containing only chelated fraction and Association of Official Analytical Chemists (AOAC) method FM-841 respectively. Adulterated Zn-EDTA samples were prepared by mixing of known quantity of mineral Zn with chelated Zn-EDTA standard. The results showed that Shahid's analytical method and AAS method, both successfully estimated the chelated fraction. The AOAC FM-841 method was insensitive to put a ceiling on the mineral fraction hence did not furnish the reliable results. The Shahid's analytical method was selected being equallyeffective to produce reliable results both for solid and liquid Zn-EDTA samples. The AAS method was comparable in only liquid samples. (author)

  11. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  12. Analytical methods for toxic gases from thermal degradation of polymers

    Science.gov (United States)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  13. Reducing waste generation and radiation exposure by analytical method modification

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.A.

    1996-10-01

    The primary goal of an analytical support laboratory has traditionally been to provide accurate data in a timely and cost effective fashion. Added to this goal is now the need to provide the same high quality data while generating as little waste as possible. At the Savannah River Technology Center (SRTC), we have modified and reengineered several methods to decrease generated waste and hence reduce radiation exposure. These method changes involved improving detection limits (which decreased the amount of sample required for analysis), decreasing reaction and analysis time, decreasing the size of experimental set-ups, recycling spent solvent and reagents, and replacing some methods. These changes had the additional benefits of reducing employee radiation exposure and exposure to hazardous chemicals. In all cases, the precision, accuracy, and detection limits were equal to or better than the replaced method. Most of the changes required little or no expenditure of funds. This paper describes these changes and discusses some of their applications.

  14. ANALYTICAL METHODS FOR KINETIC STUDIES OF BIOLOGICAL INTERACTIONS: A REVIEW

    Science.gov (United States)

    Zheng, Xiwei; Bi, Cong; Li, Zhao; Podariu, Maria; Hage, David S.

    2015-01-01

    The rates at which biological interactions occur can provide important information concerning the mechanism and behavior of these processes in living systems. This review discusses several analytical methods that can be used to examine the kinetics of biological interactions. These techniques include common or traditional methods such as stopped-flow analysis and surface plasmon resonance spectroscopy, as well as alternative methods based on affinity chromatography and capillary electrophoresis. The general principles and theory behind these approaches are examined, and it is shown how each technique can be utilized to provide information on the kinetics of biological interactions. Examples of applications are also given for each method. In addition, a discussion is provided on the relative advantages or potential limitations of each technique regarding its use in kinetic studies. PMID:25700721

  15. Selectivity in analytical chemistry: two interpretations for univariate methods.

    Science.gov (United States)

    Dorkó, Zsanett; Verbić, Tatjana; Horvai, George

    2015-01-01

    Selectivity is extremely important in analytical chemistry but its definition is elusive despite continued efforts by professional organizations and individual scientists. This paper shows that the existing selectivity concepts for univariate analytical methods broadly fall in two classes: selectivity concepts based on measurement error and concepts based on response surfaces (the response surface being the 3D plot of the univariate signal as a function of analyte and interferent concentration, respectively). The strengths and weaknesses of the different definitions are analyzed and contradictions between them unveiled. The error based selectivity is very general and very safe but its application to a range of samples (as opposed to a single sample) requires the knowledge of some constraint about the possible sample compositions. The selectivity concepts based on the response surface are easily applied to linear response surfaces but may lead to difficulties and counterintuitive results when applied to nonlinear response surfaces. A particular advantage of this class of selectivity is that with linear response surfaces it can provide a concentration independent measure of selectivity. In contrast, the error based selectivity concept allows only yes/no type decision about selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Analytical methods for the evaluation of melamine contamination.

    Science.gov (United States)

    Cantor, Stuart L; Gupta, Abhay; Khan, Mansoor A

    2014-02-01

    There is an urgent need for the analysis of melamine in the global pharmaceutical supply chain to detect economically motivated adulteration or unintentional contamination using a simple, nondestructive analytical technique that confirms the extent of adulteration in a shorter time period. In this work, different analytical techniques (thermal analysis, X-ray diffraction, Fourier transform infrared (FT-IR), FT-Raman, and near-infrared (NIR) spectroscopy) were evaluated for their ability to detect a range of melamine levels in gelatin. While FT-IR and FT-Raman provided qualitative assessment of melamine contamination or adulteration, powder X-ray diffraction and NIR were able to detect and quantify the presence of melamine at levels as low as 1.0% w/w. Multivariate analysis of the NIR data yielded the most accurate model when three principal components were used. Data were pretreated using standard normal variate transformation to remove multiplicative interferences of scatter and particle size. The model had a root-mean-square error of calibration of 2.4 (R(2) = 0.99) and root-mean square error of prediction of 2.5 (R(2) = 0.96). The value of the paired t test for actual and predicted samples (1%-50% w/w) was 0.448 (p 5), further indicating the robustness of the model. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  17. Analytical method for thermal stress analysis of plasma facing materials

    International Nuclear Information System (INIS)

    You, J.H.; Bolt, H.

    2001-01-01

    The thermo-mechanical response of plasma facing materials (PFMs) to heat loads from the fusion plasma is one of the crucial issues in fusion technology. In this work, a fully analytical description of the thermal stress distribution in armour tiles of plasma facing components is presented which is expected to occur under typical high heat flux (HHF) loads. The method of stress superposition is applied considering the temperature gradient and thermal expansion mismatch. Several combinations of PFMs and heat sink metals are analysed and compared. In the framework of the present theoretical model, plastic flow and the effect of residual stress can be quantitatively assessed. Possible failure features are discussed

  18. Analytical method for thermal stress analysis of plasma facing materials

    Science.gov (United States)

    You, J. H.; Bolt, H.

    2001-10-01

    The thermo-mechanical response of plasma facing materials (PFMs) to heat loads from the fusion plasma is one of the crucial issues in fusion technology. In this work, a fully analytical description of the thermal stress distribution in armour tiles of plasma facing components is presented which is expected to occur under typical high heat flux (HHF) loads. The method of stress superposition is applied considering the temperature gradient and thermal expansion mismatch. Several combinations of PFMs and heat sink metals are analysed and compared. In the framework of the present theoretical model, plastic flow and the effect of residual stress can be quantitatively assessed. Possible failure features are discussed.

  19. Higher geometry an introduction to advanced methods in analytic geometry

    CERN Document Server

    Woods, Frederick S

    2005-01-01

    For students of mathematics with a sound background in analytic geometry and some knowledge of determinants, this volume has long been among the best available expositions of advanced work on projective and algebraic geometry. Developed from Professor Woods' lectures at the Massachusetts Institute of Technology, it bridges the gap between intermediate studies in the field and highly specialized works.With exceptional thoroughness, it presents the most important general concepts and methods of advanced algebraic geometry (as distinguished from differential geometry). It offers a thorough study

  20. Analytical Method to Estimate the Complex Permittivity of Oil Samples

    Directory of Open Access Journals (Sweden)

    Lijuan Su

    2018-03-01

    Full Text Available In this paper, an analytical method to estimate the complex dielectric constant of liquids is presented. The method is based on the measurement of the transmission coefficient in an embedded microstrip line loaded with a complementary split ring resonator (CSRR, which is etched in the ground plane. From this response, the dielectric constant and loss tangent of the liquid under test (LUT can be extracted, provided that the CSRR is surrounded by such LUT, and the liquid level extends beyond the region where the electromagnetic fields generated by the CSRR are present. For that purpose, a liquid container acting as a pool is added to the structure. The main advantage of this method, which is validated from the measurement of the complex dielectric constant of olive and castor oil, is that reference samples for calibration are not required.

  1. Analytical method of spectra calculations in the Bargmann representation

    Energy Technology Data Exchange (ETDEWEB)

    Maciejewski, Andrzej J., E-mail: maciejka@astro.ia.uz.zgora.pl [J. Kepler Institute of Astronomy, University of Zielona Góra, Licealna 9, PL-65-417 Zielona Góra (Poland); Przybylska, Maria, E-mail: M.Przybylska@if.uz.zgora.pl [Institute of Physics, University of Zielona Góra, Licealna 9, 65-417 Zielona Góra (Poland); Stachowiak, Tomasz, E-mail: stachowiak@cft.edu.pl [Center for Theoretical Physics PAS, Al. Lotnikow 32/46, 02-668 Warsaw (Poland)

    2014-10-24

    We formulate a universal method for solving an arbitrary quantum system which, in the Bargmann representation, is described by a system of linear equations with one independent variable, such as one- and multi-photon Rabi models, or N level systems interacting with a single mode of the electromagnetic field and their various generalizations. We explain three types of conditions that determine the spectrum and show their usage for two deformations of the Rabi model. We prove that the spectra of both models are just zeros of transcendental functions, which in one case are given explicitly in terms of confluent Heun functions. - Highlights: • Analytical method of spectrum determination in Bargmann representation is proposed. • Three types of conditions determining spectrum are identified. • Method to two generalizations of the Rabi system is applied.

  2. The evolution of analytical chemistry methods in foodomics.

    Science.gov (United States)

    Gallo, Monica; Ferranti, Pasquale

    2016-01-08

    The methodologies of food analysis have greatly evolved over the past 100 years, from basic assays based on solution chemistry to those relying on the modern instrumental platforms. Today, the development and optimization of integrated analytical approaches based on different techniques to study at molecular level the chemical composition of a food may allow to define a 'food fingerprint', valuable to assess nutritional value, safety and quality, authenticity and security of foods. This comprehensive strategy, defined foodomics, includes emerging work areas such as food chemistry, phytochemistry, advanced analytical techniques, biosensors and bioinformatics. Integrated approaches can help to elucidate some critical issues in food analysis, but also to face the new challenges of a globalized world: security, sustainability and food productions in response to environmental world-wide changes. They include the development of powerful analytical methods to ensure the origin and quality of food, as well as the discovery of biomarkers to identify potential food safety problems. In the area of nutrition, the future challenge is to identify, through specific biomarkers, individual peculiarities that allow early diagnosis and then a personalized prognosis and diet for patients with food-related disorders. Far from the aim of an exhaustive review of the abundant literature dedicated to the applications of omic sciences in food analysis, we will explore how classical approaches, such as those used in chemistry and biochemistry, have evolved to intersect with the new omics technologies to produce a progress in our understanding of the complexity of foods. Perhaps most importantly, a key objective of the review will be to explore the development of simple and robust methods for a fully applied use of omics data in food science. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Selection of analytical methods for mixed waste analysis at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Morant, P.M.

    1994-09-01

    This document describes the process that the US Department of Energy (DOE), Richland Operations Office (RL) and contractor laboratories use to select appropriate or develop new or modified analytical methods. These methods are needed to provide reliable mixed waste characterization data that meet project-specific quality assurance (QA) requirements while also meeting health and safety standards for handling radioactive materials. This process will provide the technical basis for DOE`s analysis of mixed waste and support requests for regulatory approval of these new methods when they are used to satisfy the regulatory requirements of the Hanford Federal Facility Agreement and Consent Order (Tri-party Agreement) (Ecology et al. 1992).

  4. New Analytical Method for the Determination of Metronidazole in ...

    African Journals Online (AJOL)

    Methods: Metronidazole was extracted from human plasma through one step of protein precipitation by methanol using carbamazepine as internal standard (IS). After centrifugation of the plasma sample, the supernatant layer was separated and injected into HPLC system using Eclipse XDB-phenyl column. The mobile ...

  5. Analytic moment method calculations of the drift wave spectrum

    International Nuclear Information System (INIS)

    Thayer, D.R.; Molvig, K.

    1985-11-01

    A derivation and approximate solution of renormalized mode coupling equations describing the turbulent drift wave spectrum is presented. Arguments are given which indicate that a weak turbulence formulation of the spectrum equations fails for a system with negative dissipation. The inadequacy of the weak turbulence theory is circumvented by utilizing a renormalized formation. An analytic moment method is developed to approximate the solution of the nonlinear spectrum integral equations. The solution method employs trial functions to reduce the integral equations to algebraic equations in basic parameters describing the spectrum. An approximate solution of the spectrum equations is first obtained for a mode dissipation with known solution, and second for an electron dissipation in the NSA

  6. Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms

    CERN Document Server

    Williams, J J

    2013-01-01

    Modern design methods of Automotive Cam Design require the computation of a range of parameters. This book provides a logical sequence of steps for the derivation of the relevant equations from first principles, for the more widely used cam mechanisms. Although originally derived for use in high performance engines, this work is equally applicable to the design of mass produced automotive and other internal combustion engines.   Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms provides the equations necessary for the design of cam lift curves with an associated smooth acceleration curve. The equations are derived for the kinematics and kinetics of all the mechanisms considered, together with those for cam curvature and oil entrainment velocity. This permits the cam shape, all loads, and contact stresses to be evaluated, and the relevant tribology to be assessed. The effects of asymmetry on the manufacture of cams for finger follower and offset translating curved followers is ...

  7. Potentialities and possible applications of a new analytical method (PIXE)

    International Nuclear Information System (INIS)

    Pinho, A.G. de; Montenegro, E.C.; Barros Leite, C.V. de; Baptista, G.B.; Paschoa, A.S.

    1979-01-01

    In 1970, a new method was introduced for trace analysis, namely, the X-ray emission induced by charged particles (PIXE). It has been shown that when protons in the few MeV range are used for the excitation of inner shell electrons and solid state detectors for the detection of the characteristic X-rays, we dispose of a powerful multi-elemental analytical tool of high sensitivity. In contrast to activation spectrometry, this is an in beam technique, irradiation and measuring being performed at the same time. The foundations of the method are described experimental arrangements and problems related to beam transport, target preparation an spectrum analysis. A detailed discussion on precision, accuracy and sensitivity is presented. Applications in biology, medicine, environmental and materials sciences are discussed. (Author) [pt

  8. Analytical methods validation of processes control in injectable antitumor agents

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad Margarita; Cunill Semanat, Edel; Cartaya Morales, Mayra; Diaz de Arma, Anyisela; Curbelo Fonte, Yusleydis

    2010-01-01

    Alternative analytical methods were validated for the process control of 500 mg florouacil, 50 mg doxorrubicin and 50 mg methotrexate by spectrophotometry because of they are more simple and economic allowint to control the drugs quality in process analysis control. Calibration curves of fluorouracil, doxorrubicin and methotrexate were plotted in interval from 60 to 140%, where there were linear with correlation coefficients similar to 0.9998, 0.9999 and 0.9999, respectively; statistical text for intercept and slope were considered as non-significant. Recoveries of 99.97, 99.98 and 99.35% were achieved, respectively in study concentration interval and Cochran and t-Student tests were also non-significant. Methods were specific, linear, precises and exacts in interval of study concentrations

  9. GenoSets: visual analytic methods for comparative genomics.

    Directory of Open Access Journals (Sweden)

    Aurora A Cain

    Full Text Available Many important questions in biology are, fundamentally, comparative, and this extends to our analysis of a growing number of sequenced genomes. Existing genomic analysis tools are often organized around literal views of genomes as linear strings. Even when information is highly condensed, these views grow cumbersome as larger numbers of genomes are added. Data aggregation and summarization methods from the field of visual analytics can provide abstracted comparative views, suitable for sifting large multi-genome datasets to identify critical similarities and differences. We introduce a software system for visual analysis of comparative genomics data. The system automates the process of data integration, and provides the analysis platform to identify and explore features of interest within these large datasets. GenoSets borrows techniques from business intelligence and visual analytics to provide a rich interface of interactive visualizations supported by a multi-dimensional data warehouse. In GenoSets, visual analytic approaches are used to enable querying based on orthology, functional assignment, and taxonomic or user-defined groupings of genomes. GenoSets links this information together with coordinated, interactive visualizations for both detailed and high-level categorical analysis of summarized data. GenoSets has been designed to simplify the exploration of multiple genome datasets and to facilitate reasoning about genomic comparisons. Case examples are included showing the use of this system in the analysis of 12 Brucella genomes. GenoSets software and the case study dataset are freely available at http://genosets.uncc.edu. We demonstrate that the integration of genomic data using a coordinated multiple view approach can simplify the exploration of large comparative genomic data sets, and facilitate reasoning about comparisons and features of interest.

  10. National Cancer Institute Biospecimen Evidence-Based Practices: a novel approach to pre-analytical standardization.

    Science.gov (United States)

    Engel, Kelly B; Vaught, Jim; Moore, Helen M

    2014-04-01

    Variable biospecimen collection, processing, and storage practices may introduce variability in biospecimen quality and analytical results. This risk can be minimized within a facility through the use of standardized procedures; however, analysis of biospecimens from different facilities may be confounded by differences in procedures and inferred biospecimen quality. Thus, a global approach to standardization of biospecimen handling procedures and their validation is needed. Here we present the first in a series of procedural guidelines that were developed and annotated with published findings in the field of human biospecimen science. The series of documents will be known as NCI Biospecimen Evidence-Based Practices, or BEBPs. Pertinent literature was identified via the National Cancer Institute (NCI) Biospecimen Research Database ( brd.nci.nih.gov ) and findings were organized by specific biospecimen pre-analytical factors and analytes of interest (DNA, RNA, protein, morphology). Meta-analysis results were presented as annotated summaries, which highlight concordant and discordant findings and the threshold and magnitude of effects when applicable. The detailed and adaptable format of the document is intended to support the development and execution of evidence-based standard operating procedures (SOPs) for human biospecimen collection, processing, and storage operations.

  11. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  12. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  13. USING ANALYTIC HIERARCHY PROCESS (AHP METHOD IN RURAL DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Tülay Cengiz

    2003-04-01

    Full Text Available Rural development is a body of economical and social policies towards improving living conditions in rural areas through enabling rural population to utilize economical, social, cultural and technological blessing of city life in place, without migrating. As it is understood from this description, rural development is a very broad concept. Therefore, in development efforts problem should be stated clearly, analyzed and many criterias should be evaluated by experts. Analytic Hierarchy Process (AHP method can be utilized at there stages of development efforts. AHP methods is one of multi-criteria decision method. After degrading a problem in smaller pieces, relative importance and level of importance of two compared elements are determined. It allows evaluation of quality and quantity factors. At the same time, it permits utilization of ideas of many experts and use them in decision process. Because mentioned features of AHP method, it could be used in rural development works. In this article, cultural factors, one of the important components of rural development is often ignored in many studies, were evaluated as an example. As a result of these applications and evaluations, it is concluded that AHP method could be helpful in rural development efforts.

  14. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    Analytical Method of Auxiliary Sources solutions for plane wave scattering by circular impedance cylinders are derived by transformation of the exact eigenfunction series solutions employing the Hankel function wave transformation. The analytical Method of Auxiliary Sources solution thus obtained...

  15. Computational and analytical methods in nonlinear fluid dynamics

    Science.gov (United States)

    Walker, James

    1993-09-01

    The central focus of the program was on the application and development of modern analytical and computational methods to the solution of nonlinear problems in fluid dynamics and reactive gas dynamics. The research was carried out within the Division of Engineering Mathematics in the Department of Mechanical Engineering and Mechanics and principally involved Professors P.A. Blythe, E. Varley and J.D.A. Walker. In addition. the program involved various international collaborations. Professor Blythe completed work on reactive gas dynamics with Professor D. Crighton FRS of Cambridge University in the United Kingdom. Professor Walker and his students carried out joint work with Professor F.T. Smith, of University College London, on various problems in unsteady flow and turbulent boundary layers.

  16. Laser induced uranium fluorescence as an analytical method

    International Nuclear Information System (INIS)

    Krutman, I.

    1985-01-01

    A laser induced fluorescence system was developed to measure uranium trace level amounts in aqueous solution with reliable and simple materials and electronics. A nitrogen pulsed laser was built with the storage energy capacitor directly coupled to laser tube electrodes as a transmission line device. This laser operated at 3Hz repetition rate with peak intensity around 21 Kw and temporal width of 4.5 x 10 -9 s. A sample compartment made of rigid PVC and a photomultiplier housing of aluminium were constructed and assembled forming a single integrated device. As a result of this prototype system we made several analytical measurements with U dissolved in nitric acid to obtain a calibration curve. We obtained a straight line from a plot of U concentration versus fluorescence intensity fitted by a least square method that produced a regression coefficient of 0.994. The lower limit of U determination was 30 ppb -+ 3.5%. (Author) [pt

  17. Analytical methods and problems for the diamides type of extractants

    International Nuclear Information System (INIS)

    Cuillerdier, C.; Nigond, L.; Musikas, C.; Vitart, H.; Hoel, P.

    1989-01-01

    Diamides of carboxylic acids and especially malonamides are able to extract alpha emitters (including trivalent ions such as Am and Cm) contained in the wastes solutions of the nuclear industry. As they are completely incinerable and easy to purify, they could be an alternative to the mixture CMPO-TBP which is used in the TRUEX process. A large oxyalkyl radical enhances the distribution coefficients of americium in nitric acid sufficiently to permit the decontamination of wastes solutions in a classical mixers-settlers battery. Now researches are pursued with the aim of optimizing the formula of extractant, the influence of the structure of the extractant on its basicity and stability under radiolysis and hydrolysis is investigated. Analytical methods (potentiometry and NMR of C 13 ) have been developed for solvent titration and to evaluate the percentage of degradation and to identify some of the degradation products

  18. Nuclear analytical methods for trace element studies in calcified tissues

    International Nuclear Information System (INIS)

    Chaudhry, M.A.; Chaudhry, M.N.

    2001-01-01

    Full text: Various nuclear analytical methods have been developed and applied to determine the elemental composition of calcified tissues (teeth and bones). Fluorine was determined by prompt gamma activation analysis through the 19 F(p,ag) 16 O reaction. Carbon was measured by activation analysis with He-3 ions, and the technique of Proton-Induced X-ray Emission (PIXE) was applied to simultaneously determine Ca, P, and trace elements in well-documented teeth. Dental hard tissues, enamel, dentine, cement, and their junctions, as well as different parts of the same tissue, were examined separately. Furthermore, using a Proton Microprobe, we measured the surface distribution of F and other elements on and around carious lesions on the enamel. The depth profiles of F, and other elements, were also measured right up to the amelodentin junction

  19. Application of analytical methods in authentication and adulteration of honey.

    Science.gov (United States)

    Siddiqui, Amna Jabbar; Musharraf, Syed Ghulam; Choudhary, M Iqbal; Rahman, Atta-Ur-

    2017-02-15

    Honey is synthesized from flower nectar and it is famous for its tremendous therapeutic potential since ancient times. Many factors influence the basic properties of honey including the nectar-providing plant species, bee species, geographic area, and harvesting conditions. Quality and composition of honey is also affected by many other factors, such as overfeeding of bees with sucrose, harvesting prior to maturity, and adulteration with sugar syrups. Due to the complex nature of honey, it is often challenging to authenticate the purity and quality by using common methods such as physicochemical parameters and more specialized procedures need to be developed. This article reviews the literature (between 2000 and 2016) on the use of analytical techniques, mainly NMR spectroscopy, for authentication of honey, its botanical and geographical origin, and adulteration by sugar syrups. NMR is a powerful technique and can be used as a fingerprinting technique to compare various samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Analytical methods used in plutonium purification cycles by trilaurylamine

    International Nuclear Information System (INIS)

    Perez, J.J.

    1965-01-01

    The utilisation of trilaurylamine as a solvent extractant for the purification of plutonium has entailed to perfect a set of analytical methods which involves, various techniques. The organic impurities of the solvent can be titrated by gas-liquid chromatography. The titration of the main degradation product, the di-laurylamine, can be accomplished also by spectro-colorimetry. Potentiometry is used for the analysis of the different salts of amine-nitrate-sulfate-bisulfate as also the extracted nitric acid. The determination of the nitrate in aqueous phase is carried out by constant current potentiometry. The range of application, the accuracy and the procedure of these analysis are related in the present report. (author) [fr

  1. Precision profiles and analytic reliability of radioimmunologic methods

    International Nuclear Information System (INIS)

    Yaneva, Z.; Popova, Yu.

    1991-01-01

    The aim of the present study is to investigate and compare some methods for creation of 'precision profiles' (PP) and to clarify their possibilities for determining the analytical reliability of RIA. Only methods without complicated mathematical calculations has been used. The reproducibility in serums with a concentration of the determinable hormone in the whole range of the calibration curve has been studied. The radioimmunoassay has been performed with TSH-RIA set (ex East Germany), and comparative evaluations - with commercial sets of HOECHST (Germany) and AMERSHAM (GB). Three methods for obtaining the relationship concentration (IU/l) -reproducibility (C.V.,%) are used and a comparison is made of their corresponding profiles: preliminary rough profile, Rodbard-PP and Ekins-PP. It is concluded that the creation of a precision profile is obligatory and the method of its construction does not influence the relationship's course. PP allows to determine concentration range giving stable results which improves the efficiency of the analitical work. 16 refs., 4 figs

  2. A Meta-Analytic Assessment of Empirical Differences in Standard Setting Procedures.

    Science.gov (United States)

    Bontempo, Brian D.; Marks, Casimer M.; Karabatsos, George

    Using meta-analysis, this research takes a look at studies included in a meta-analysis by R. Jaeger (1989) that compared the cut score set by one standard setting method with that set by another. This meta-analysis looks beyond Jaeger's studies to select 10 from the research literature. Each compared at least two types of standard setting method.…

  3. Free and Forced Vibration Analysis of an Infilled Steel Frame: Experimental, Numerical, and Analytical Methods

    Directory of Open Access Journals (Sweden)

    Mohammad Amin Hariri-Ardebili

    2014-01-01

    Full Text Available Structural frames with masonry infill panels make up a significant portion of the buildings constructed in earthquake-prone areas prior to the developing of the seismic design standards. In this paper, the effects of masonry panels on the vibration response of an infilled steel-frame building are investigated. Various ambient and steady state forced vibration tests are carried out to realize the dynamic characteristics of the system. 3D finite element models of the building with and without infill panels are provided based on marcomodeling theorem. A set of analytical approximate formulas are also derived to estimate the vibrational period. The natural frequencies of the building are computed using numerical, analytical, and experimental methods. The results show that neglecting the effect of infill panels leads to considerable error. Moreover, it is shown that there is good agreement among the results obtained by the three methods considering the effect of infill panels.

  4. The Objective Borderline Method: A Probabilistic Method for Standard Setting

    Science.gov (United States)

    Shulruf, Boaz; Poole, Phillippa; Jones, Philip; Wilkinson, Tim

    2015-01-01

    A new probability-based standard setting technique, the Objective Borderline Method (OBM), was introduced recently. This was based on a mathematical model of how test scores relate to student ability. The present study refined the model and tested it using 2500 simulated data-sets. The OBM was feasible to use. On average, the OBM performed well…

  5. International symposium on quality assurance for analytical methods in isotope hydrology. Book of extended synopses

    International Nuclear Information System (INIS)

    2004-01-01

    A large variety of isotopic techniques is available and commonly used in water resources investigations as well as in a wide range of other scientific fields. These techniques include the stable isotope analysis of light elements (H, C, N, O, S), activity measurements of radioactive isotopes at environmental level (3H, 14C, 3H/3He, 85Kr) as well as measurements of CFCs, SF6 and other chemical and isotopic tracers. They provide valuable tools for the assessment of scientific questions and the solution of practical problems. During the last decade, new analytical tools have significantly fostered the application of isotopic techniques in many new fields and caused a steep increase in the number of laboratories applying these methods. International trends in improved analytical quality and requirements for laboratory certification and accreditation have pushed issues of quality control and quality assurance to a high level of importance for the operation of isotope laboratories worldwide. The objectives of the symposium are to promote a wide exchange of information on key issues for high quality isotopic measurements. The main focus is on the analytical techniques and on all means to ensure high quality standards for isotopic measurements. Recent advances in analytical quality assurance and laboratory quality systems will be presented and discussed together with state-of-the-art techniques. The scope of the conference is to demonstrate the use of best laboratory practices in the following fields: calibration of measurements and traceability; interlaboratory comparisons; best laboratory practices for daily analyses of samples; quality control and statistical evaluation of results; calculation of uncertainty budgets; new analytical techniques; improvements in precision and accuracy of analytical methods; laboratory information management, databases and sample handling; laboratory quality systems and international guides. The 42 papers are indexed individually

  6. Analytical maximum-likelihood method to detect patterns in real networks

    International Nuclear Information System (INIS)

    Squartini, Tiziano; Garlaschelli, Diego

    2011-01-01

    In order to detect patterns in real networks, randomized graph ensembles that preserve only part of the topology of an observed network are systematically used as fundamental null models. However, the generation of them is still problematic. Existing approaches are either computationally demanding and beyond analytic control or analytically accessible but highly approximate. Here, we propose a solution to this long-standing problem by introducing a fast method that allows one to obtain expectation values and standard deviations of any topological property analytically, for any binary, weighted, directed or undirected network. Remarkably, the time required to obtain the expectation value of any property analytically across the entire graph ensemble is as short as that required to compute the same property using the adjacency matrix of the single original network. Our method reveals that the null behavior of various correlation properties is different from what was believed previously, and is highly sensitive to the particular network considered. Moreover, our approach shows that important structural properties (such as the modularity used in community detection problems) are currently based on incorrect expressions, and provides the exact quantities that should replace them.

  7. A fast analytical method for the addition of random variables

    International Nuclear Information System (INIS)

    Senna, V.; Milidiu, R.L.; Fleming, P.V.; Salles, M.R.; Oliveira, L.F.S. de

    1982-01-01

    Using the minimal cut sets representation of a fault tree, a new approach to the method of moments is proposed in order to estimate confidence bounds to the top event probability. The method utilizes two or three moments either to fit a distribution (the normal and lognormal families) or to evaluate bounds from standard inequalities (e.g. Markov, Tchebycheff, etc.). Examples indicate that the results obtained by the lognormal family are in good agreement with those obtained by Monte Carlo simulation. (Author) [pt

  8. Fast analytical method for the addition of random variables

    International Nuclear Information System (INIS)

    Senna, V.; Milidiu, R.L.; Fleming, P.V.; Salles, M.R.; Oliveria, L.F.S.

    1983-01-01

    Using the minimal cut sets representation of a fault tree, a new approach to the method of moments is proposed in order to estimate confidence bounds to the top event probability. The method utilizes two or three moments either to fit a distribution (the normal and lognormal families) or to evaluate bounds from standard inequalities (e.g. Markov, Tchebycheff, etc.) Examples indicate that the results obtained by the log-normal family are in good agreement with those obtained by Monte Carlo simulation

  9. Groundwater Seepage Estimation into Amirkabir Tunnel Using Analytical Methods and DEM and SGR Method

    OpenAIRE

    Hadi Farhadian; Homayoon Katibeh

    2015-01-01

    In this paper, groundwater seepage into Amirkabir tunnel has been estimated using analytical and numerical methods for 14 different sections of the tunnel. Site Groundwater Rating (SGR) method also has been performed for qualitative and quantitative classification of the tunnel sections. The obtained results of above mentioned methods were compared together. The study shows reasonable accordance with results of the all methods unless for two sections of tunnel. In these t...

  10. Analytical methods associated with the recovery of uranium

    International Nuclear Information System (INIS)

    Dixon, K.

    1983-01-01

    This report summarizes various approaches made to the analysis of materials arising from the processing of Karoo deposits for uranium. These materials include head and residue samples, aqueous solutions and organic solvents and, finally, the precipitated cakes of the elements recovered, i.e. uranium, molybdenum, and arsenic. Analysis was required for these elements and also vanadium, carbon, sulphur, and carbonate in the head and residue samples. The concentration of uranium, molybdenum, and arsenic, other than in the precipitated cakes, ranges from 1 to 2000μg/g, and that of carbon, sulphur, and carbonate from 0,1 to 5 per cent. The analysis of cakes necessitates the determination of silver, arsenic, iron, copper, calcium, magnesium, manganese, molybdenum, lead, tin, titanium, and vanadium within the range 1 to 1000μg/g, and of sodium and silica within the range 10 to 20 000μg/g. The methods used include combustion methods for carbon, sulphur, and carbonate, and atomic-absorption, X-ray-fluorescence, and emission methods for the other analytes. The accuracy of the analysis is within 10 per cent

  11. Analytical resource assessment method for continuous (unconventional) oil and gas accumulations - The "ACCESS" Method

    Science.gov (United States)

    Crovelli, Robert A.; revised by Charpentier, Ronald R.

    2012-01-01

    The U.S. Geological Survey (USGS) periodically assesses petroleum resources of areas within the United States and the world. The purpose of this report is to explain the development of an analytic probabilistic method and spreadsheet software system called Analytic Cell-Based Continuous Energy Spreadsheet System (ACCESS). The ACCESS method is based upon mathematical equations derived from probability theory. The ACCESS spreadsheet can be used to calculate estimates of the undeveloped oil, gas, and NGL (natural gas liquids) resources in a continuous-type assessment unit. An assessment unit is a mappable volume of rock in a total petroleum system. In this report, the geologic assessment model is defined first, the analytic probabilistic method is described second, and the spreadsheet ACCESS is described third. In this revised version of Open-File Report 00-044 , the text has been updated to reflect modifications that were made to the ACCESS program. Two versions of the program are added as appendixes.

  12. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.

    Science.gov (United States)

    Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-01

    An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Long-term variability in sugarcane bagasse feedstock compositional methods: sources and magnitude of analytical variability.

    Science.gov (United States)

    Templeton, David W; Sluiter, Justin B; Sluiter, Amie; Payne, Courtney; Crocker, David P; Tao, Ling; Wolfrum, Ed

    2016-01-01

    In an effort to find economical, carbon-neutral transportation fuels, biomass feedstock compositional analysis methods are used to monitor, compare, and improve biofuel conversion processes. These methods are empirical, and the analytical variability seen in the feedstock compositional data propagates into variability in the conversion yields, component balances, mass balances, and ultimately the minimum ethanol selling price (MESP). We report the average composition and standard deviations of 119 individually extracted National Institute of Standards and Technology (NIST) bagasse [Reference Material (RM) 8491] run by seven analysts over 7 years. Two additional datasets, using bulk-extracted bagasse (containing 58 and 291 replicates each), were examined to separate out the effects of batch, analyst, sugar recovery standard calculation method, and extractions from the total analytical variability seen in the individually extracted dataset. We believe this is the world's largest NIST bagasse compositional analysis dataset and it provides unique insight into the long-term analytical variability. Understanding the long-term variability of the feedstock analysis will help determine the minimum difference that can be detected in yield, mass balance, and efficiency calculations. The long-term data show consistent bagasse component values through time and by different analysts. This suggests that the standard compositional analysis methods were performed consistently and that the bagasse RM itself remained unchanged during this time period. The long-term variability seen here is generally higher than short-term variabilities. It is worth noting that the effect of short-term or long-term feedstock compositional variability on MESP is small, about $0.03 per gallon. The long-term analysis variabilities reported here are plausible minimum values for these methods, though not necessarily average or expected variabilities. We must emphasize the importance of training and good

  14. Comparation of fundamental analytical methods for quantitative determination of copper(IIion

    Directory of Open Access Journals (Sweden)

    Ačanski Marijana M.

    2008-01-01

    Full Text Available Copper is a ductile metal with excellent electrical conductivity, and finds extensive use as an electrical conductor, heat conductor, as a building material, and as a component of various alloys. In this work accuracy of methods for quantitative determination (gravimetric and titrimetric methods of analysis of copper(II ion was studied. Gravimetric methods do not require a calibration or standardization step (as all other analytical procedures except coulometry do because the results are calculated directly from the experimental data and molar masses. Thus, when only one or two samples are to be analyzed, a gravimetric procedure may be the method of choice because it involves less time and effort than a procedure that requires preparation of standards and calibration. In this work in gravimetric analysis the concentration of copper(II ion is established through the measurement of a mass of CuSCN and CuO. Titrimetric methods is a process in which a standard reagent is added to a solution of an analyze until the reaction between the analyze and reagent is judged to be complete. In this work in titrimetric analysis the concentration of copper(II ion is established through the measurement of a volume of different standard reagents: Km, Na2S2O3 and AgNO3. Results were discussed individually and mutually with the aspect of exactility, reproductivity and rapidity. Relative error was calculated for all methods.

  15. An analytical method for predicting postwildfire peak discharges

    Science.gov (United States)

    Moody, John A.

    2012-01-01

    An analytical method presented here that predicts postwildfire peak discharge was developed from analysis of paired rainfall and runoff measurements collected from selected burned basins. Data were collected from 19 mountainous basins burned by eight wildfires in different hydroclimatic regimes in the western United States (California, Colorado, Nevada, New Mexico, and South Dakota). Most of the data were collected for the year of the wildfire and for 3 to 4 years after the wildfire. These data provide some estimate of the changes with time of postwildfire peak discharges, which are known to be transient but have received little documentation. The only required inputs for the analytical method are the burned area and a quantitative measure of soil burn severity (change in the normalized burn ratio), which is derived from Landsat reflectance data and is available from either the U.S. Department of Agriculture Forest Service or the U.S. Geological Survey. The method predicts the postwildfire peak discharge per unit burned area for the year of a wildfire, the first year after a wildfire, and the second year after a wildfire. It can be used at three levels of information depending on the data available to the user; each subsequent level requires either more data or more processing of the data. Level 1 requires only the burned area. Level 2 requires the burned area and the basin average value of the change in the normalized burn ratio. Level 3 requires the burned area and the calculation of the hydraulic functional connectivity, which is a variable that incorporates the sequence of soil burn severity along hillslope flow paths within the burned basin. Measurements indicate that the unit peak discharge response increases abruptly when the 30-minute maximum rainfall intensity is greater than about 5 millimeters per hour (0.2 inches per hour). This threshold may relate to a change in runoff generation from saturated-excess to infiltration-excess overland flow. The

  16. Measurement of company effectiveness using analytic network process method

    Science.gov (United States)

    Goran, Janjić; Zorana, Tanasić; Borut, Kosec

    2017-07-01

    The sustainable development of an organisation is monitored through the organisation's performance, which beforehand incorporates all stakeholders' requirements in its strategy. The strategic management concept enables organisations to monitor and evaluate their effectiveness along with efficiency by monitoring of the implementation of set strategic goals. In the process of monitoring and measuring effectiveness, an organisation can use multiple-criteria decision-making methods as help. This study uses the method of analytic network process (ANP) to define the weight factors of the mutual influences of all the important elements of an organisation's strategy. The calculation of an organisation's effectiveness is based on the weight factors and the degree of fulfilment of the goal values of the strategic map measures. New business conditions influence the changes in the importance of certain elements of an organisation's business in relation to competitive advantage on the market, and on the market, increasing emphasis is given to non-material resources in the process of selection of the organisation's most important measures.

  17. Measurement of company effectiveness using analytic network process method

    Directory of Open Access Journals (Sweden)

    Goran Janjić

    2017-07-01

    Full Text Available The sustainable development of an organisation is monitored through the organisation’s performance, which beforehand incorporates all stakeholders’ requirements in its strategy. The strategic management concept enables organisations to monitor and evaluate their effectiveness along with efficiency by monitoring of the implementation of set strategic goals. In the process of monitoring and measuring effectiveness, an organisation can use multiple-criteria decision-making methods as help. This study uses the method of analytic network process (ANP to define the weight factors of the mutual influences of all the important elements of an organisation’s strategy. The calculation of an organisation’s effectiveness is based on the weight factors and the degree of fulfilment of the goal values of the strategic map measures. New business conditions influence the changes in the importance of certain elements of an organisation’s business in relation to competitive advantage on the market, and on the market, increasing emphasis is given to non-material resources in the process of selection of the organisation’s most important measures.

  18. Analytic-numerical method of determining the freezing front location

    Directory of Open Access Journals (Sweden)

    R. Grzymkowski

    2011-07-01

    Full Text Available Mathematical modeling of thermal processes combined with the reversible phase transitions of type: solid phase – liquid phase leads to formulation of the parabolic boundary problems with the moving boundary. Solution of such defined problem requires, most often, to use sophisticated numerical techniques and far advanced mathematical tools. Excellent illustration of the complexity of considered problems, as well as of the variety of approaches used for finding their solutions, gives the papers [1-4]. In the current paper, the authors present the, especially attractive from the engineer point of view, analytic-numerical method for finding the approximate solution of selected class of problems which can be reduced to the one-phase solidification problem of a plate with the unknown a priori, varying in time boundary of the region in which the solution is sought. Proposed method is based on the known formalism of initial expansion of the sought function describing the temperature field into the power series, some coefficients of which are determined with the aid of boundary conditions, and on the approximation of the function defining the location of freezing front with the broken line, parameters of which are numerically determined.

  19. Quality control and analytical methods for baculovirus-based products.

    Science.gov (United States)

    Roldão, António; Vicente, Tiago; Peixoto, Cristina; Carrondo, Manuel J T; Alves, Paula M

    2011-07-01

    Recombinant baculoviruses (rBac) are used for many different applications, ranging from bio-insecticides to the production of heterologous proteins, high-throughput screening of gene functions, drug delivery, in vitro assembly studies, design of antiviral drugs, bio-weapons, building blocks for electronics, biosensors and chemistry, and recently as a delivery system in gene therapy. Independent of the application, the quality, quantity and purity of rBac-based products are pre-requisites demanded by regulatory authorities for product licensing. To guarantee maximization utility, it is necessary to delineate optimized production schemes either using trial-and-error experimental setups ("brute force" approach) or rational design of experiments by aid of in silico mathematical models (Systems Biology approach). For that, one must define all of the main steps in the overall process, identify the main bioengineering issues affecting each individual step and implement, if required, accurate analytical methods for product characterization. In this review, current challenges for quality control (QC) technologies for up- and down-stream processing of rBac-based products are addressed. In addition, a collection of QC methods for monitoring/control of the production of rBac derived products are presented as well as innovative technologies for faster process optimization and more detailed product characterization. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Modern analytic methods applied to the art and archaeology

    International Nuclear Information System (INIS)

    Tenorio C, M. D.; Longoria G, L. C.

    2010-01-01

    The interaction of diverse areas as the analytic chemistry, the history of the art and the archaeology has allowed the development of a variety of techniques used in archaeology, in conservation and restoration. These methods have been used to date objects, to determine the origin of the old materials and to reconstruct their use and to identify the degradation processes that affect the integrity of the art works. The objective of this chapter is to offer a general vision on the researches that have been realized in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of cultural goods. A series of researches carried out in collaboration with national investigators and of the foreigner is described shortly, as well as with the great support of degree students and master in archaeology of the National School of Anthropology and History, since one of the goals that have is to diffuse the knowledge of the existence of these techniques among the young archaeologists, so that they have a wider vision of what they could use in an in mediate future and they can check hypothesis with scientific methods. (Author)

  1. Development of analytical methods for iodine speciation in fresh water

    International Nuclear Information System (INIS)

    Takaku, Yuichi; Ohtsuka, Yoshihito; Hisamatsu, Shun'ichi

    2007-01-01

    Analytical methods for physicochemical speciation of iodine in fresh water samples were developed to elucidate its behavior in the environment. The methods combined inductively coupled plasma mass spectrometry (ICP-MS) with size exclusion high performance liquid chromatography (SEC) or capillary electrophoresis (CE). Freshwater samples were collected from Lake Towada and rivers surrounding the lake. After filtration through a 0.45 μm pore size membrane filter, iodine in the water samples was pre-concentrated with an ultra-filtration filter which had a cut-off size of 10 kDa. The fraction with molecular size over 10 kDa was concentrated to 100 times in the original water, and then introduced into the SEC-ICP-MS. Molecular size chromatograms of all river and lake water samples showed two peaks for iodine concentrations: 40 kDa and 20 kDa. The method for separately determining two valence states of inorganic iodine, I - and IO 3 - , was also developed using the CE-ICP-MS system and it was successfully applied to the fresh water samples. Analysis results of surface water samples in Lake Towada and rivers surrounding the lake indicated that the chemical form of inorganic iodine in all samples was IO 3 - . Additional lake water samples were collected from Lake O-ike-higashi in the Juni-ko area at Shirakami-Sanchi, which is a UNESCO natural world heritage. The lake has a strong thermocline during all seasons; its bottom layer is in a highly reductive state. Depth profiles of I - and IO 3 - clearly showed that I - was not detected in the surface layer, but it was predominant in the bottom layer, and vice versa for IO 3 - . As this separation method is rapid and sensitive, it will be widely used in the future. (author)

  2. Propulsion and launching analysis of variable-mass rockets by analytical methods

    OpenAIRE

    D.D. Ganji; M. Gorji; M. Hatami; A. Hasanpour; N. Khademzadeh

    2013-01-01

    In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM), homotopy perturbation method (HPM) and least square method (LSM) were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a paramet...

  3. Analytical one parameter method for PID motion controller settings

    NARCIS (Netherlands)

    van Dijk, Johannes; Aarts, Ronald G.K.M.

    2012-01-01

    In this paper analytical expressions for PID-controllers settings for electromechanical motion systems are presented. It will be shown that by an adequate frequency domain oriented parametrization, the parameters of a PID-controller are analytically dependent on one variable only, the cross-over

  4. Results of an interlaboratory comparison of analytical methods for contaminants of emerging concern in water.

    Science.gov (United States)

    Vanderford, Brett J; Drewes, Jörg E; Eaton, Andrew; Guo, Yingbo C; Haghani, Ali; Hoppe-Jones, Christiane; Schluesener, Michael P; Snyder, Shane A; Ternes, Thomas; Wood, Curtis J

    2014-01-07

    An evaluation of existing analytical methods used to measure contaminants of emerging concern (CECs) was performed through an interlaboratory comparison involving 25 research and commercial laboratories. In total, 52 methods were used in the single-blind study to determine method accuracy and comparability for 22 target compounds, including pharmaceuticals, personal care products, and steroid hormones, all at ng/L levels in surface and drinking water. Method biases ranged from caffeine, NP, OP, and triclosan had false positive rates >15%. In addition, some methods reported false positives for 17β-estradiol and 17α-ethynylestradiol in unspiked drinking water and deionized water, respectively, at levels higher than published predicted no-effect concentrations for these compounds in the environment. False negative rates were also generally contamination, misinterpretation of background interferences, and/or inappropriate setting of detection/quantification levels for analysis at low ng/L levels. The results of both comparisons were collectively assessed to identify parameters that resulted in the best overall method performance. Liquid chromatography-tandem mass spectrometry coupled with the calibration technique of isotope dilution were able to accurately quantify most compounds with an average bias of <10% for both matrixes. These findings suggest that this method of analysis is suitable at environmentally relevant levels for most of the compounds studied. This work underscores the need for robust, standardized analytical methods for CECs to improve data quality, increase comparability between studies, and help reduce false positive and false negative rates.

  5. Quantification of active infliximab in human serum with liquid chromatography-tandem mass spectrometry using a tumor necrosis factor alpha -based pre-analytical sample purification and a stable isotopic labeled infliximab bio-similar as internal standard: A target-based, sensitive and cost-effective method.

    Science.gov (United States)

    El Amrani, Mohsin; van den Broek, Marcel P H; Göbel, Camiel; van Maarseveen, Erik M

    2016-07-08

    The therapeutic monoclonal antibody Infliximab (IFX) is a widely used drug for the treatment of several inflammatory autoimmune diseases. However, approximately 10% of patients develop anti-infliximab antibodies (ATIs) rendering the treatment ineffective. Early detection of underexposure to unbound IFX would result in a timely switch of therapy which could aid in the treatment of this disease. Streptavidin coated 96 well plates were used to capture biotinylated-tumor necrosis factor -alpha (b-TNF-α), which in turn was used to selectively extract the active form of IFX in human serum. After elution, IFX was digested using trypsin and one signature peptide was selected for subsequent analysis on liquid chromatography-tandem mass spectrometry (LC-MS/MS). The internal standard used was a stable isotopic labeled IFX bio-similar. The assay was successfully validated according to European Medicines Agency (EMA) guidelines and was found to be linear in a range of 0.5-20μg/mL (r(2)=0.994). Lower limit of quantification for the assay (<20% CV) was 0.5μg/mL, requiring only 2μL of sample. Cross-validation against enzyme-linked immunosorbent assay (ELISA) resulted in a high correlation between methods (r(2)=0.95 with a ρc=0.83) and the accuracy was in line with previously published results. In conclusion, a sensitive, robust and cost-effective method was developed for the bio-analysis of IFX with LC-MS/MS by means of a target-based pre-analytical sample purification. Moreover, low volume and costs of consumables per sample promote its feasibility in (pre)clinical studies and in therapeutic drug monitoring. This method should be considered as first choice due to its accuracy and multiple degree of selectivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Oxcarbazepine: validation and application of an analytical method

    Directory of Open Access Journals (Sweden)

    Paula Cristina Rezende Enéas

    2010-06-01

    Full Text Available Oxcarbazepine (OXC is an important anticonvulsant and mood stabilizing drug. A pharmacopoeial monograph for OXC is not yet available and therefore the development and validation of a new analytical method for quantification of this drug is essential. In the present study, a UV spectrophotometric method for the determination of OXC was developed. The various parameters, such as linearity, precision, accuracy and specificity, were studied according to International Conference on Harmonization Guidelines. Batches of 150 mg OXC capsules were prepared and analyzed using the validated UV method. The formulations were also evaluated for parameters including drug-excipient compatibility, flowability, uniformity of weight, disintegration time, assay, uniformity of content and the amount of drug dissolved during the first hour.Oxcarbazepina (OXC é um fármaco anticonvulsivante e estabilizante do humor. O desenvolvimento e validação de método analítico para quantificação da OXC são de fundamental importância devido à ausência de monografias farmacopéicas oficiais para esse fármaco. Nesse trabalho, um método espectrofotométrico UV para determinação da OXC foi desenvolvido. O método proposto foi validado seguindo os parâmetros de linearidade, precisão, exatidão e especificidade de acordo com as normas da Conferência Internacional de Harmonização. Cápsulas de OXC 150 mg foram preparadas e analisadas utilizando-se o método analítico validado. As formulações foram avaliadas com relação à compatibilidade fármaco-excipientes, fluidez, determinação de peso, tempo de desintegração, doseamento, uniformidade de conteúdo e quantidade do fármaco dissolvido após 60 minutos.

  7. AN ANALYTICAL METHOD FOR CHEMICAL SPECIATION OF SELENIUM IN SOIL

    Directory of Open Access Journals (Sweden)

    Constantin Luca

    2010-10-01

    Full Text Available Selenium is an essential microelement, sometimes redoubtable, through its beneficial role - risk depending on its concentration in the food chain, at low dose is an important nutrient in the life of humans and animals, contrary at high doses, it becomes toxic. Selenium may be find itself in the environment (soil, sediment, water in many forms (oxidized, reduced, organometallic which determine their mobility and toxicity. Determination of chemical speciation (identification of different chemical forms provides much more complete information for a better understanding of the behavior and the potential impact on the environment. In this work we present the results of methodological research on the extraction of sequential forms of selenium in the soil and the coupling of analytical methods capable of identifying very small amounts of selenium in soils An efficient scheme of sequential extractions forms of selenium (SES consisting in atomic absorption spectrometry coupled with hydride generation (HGAAS has been developed into five experimental steps, detailed in the paper. This operational scheme has been applied to the analysis of chemical speciation in the following areas: the Bărăgan Plain and Central Dobrogea of Romania.

  8. Analytical method to estimate resin cement diffusion into dentin

    Science.gov (United States)

    de Oliveira Ferraz, Larissa Cristina; Ubaldini, Adriana Lemos Mori; de Oliveira, Bruna Medeiros Bertol; Neto, Antonio Medina; Sato, Fracielle; Baesso, Mauro Luciano; Pascotto, Renata Corrêa

    2016-05-01

    This study analyzed the diffusion of two resin luting agents (resin cements) into dentin, with the aim of presenting an analytical method for estimating the thickness of the diffusion zone. Class V cavities were prepared in the buccal and lingual surfaces of molars (n=9). Indirect composite inlays were luted into the cavities with either a self-adhesive or a self-etch resin cement. The teeth were sectioned bucco-lingually and the cement-dentin interface was analyzed by using micro-Raman spectroscopy (MRS) and scanning electron microscopy. Evolution of peak intensities of the Raman bands, collected from the functional groups corresponding to the resin monomer (C-O-C, 1113 cm-1) present in the cements, and the mineral content (P-O, 961 cm-1) in dentin were sigmoid shaped functions. A Boltzmann function (BF) was then fitted to the peaks encountered at 1113 cm-1 to estimate the resin cement diffusion into dentin. The BF identified a resin cement-dentin diffusion zone of 1.8±0.4 μm for the self-adhesive cement and 2.5±0.3 μm for the self-etch cement. This analysis allowed the authors to estimate the diffusion of the resin cements into the dentin. Fitting the MRS data to the BF contributed to and is relevant for future studies of the adhesive interface.

  9. NIOSH Manual of Analytical Methods (third edition). Fourth supplement

    Energy Technology Data Exchange (ETDEWEB)

    1990-08-15

    The NIOSH Manual of Analytical Methods, 3rd edition, was updated for the following chemicals: allyl-glycidyl-ether, 2-aminopyridine, aspartame, bromine, chlorine, n-butylamine, n-butyl-glycidyl-ether, carbon-dioxide, carbon-monoxide, chlorinated-camphene, chloroacetaldehyde, p-chlorophenol, crotonaldehyde, 1,1-dimethylhydrazine, dinitro-o-cresol, ethyl-acetate, ethyl-formate, ethylenimine, sodium-fluoride, hydrogen-fluoride, cryolite, sodium-hexafluoroaluminate, formic-acid, hexachlorobutadiene, hydrogen-cyanide, hydrogen-sulfide, isopropyl-acetate, isopropyl-ether, isopropyl-glycidyl-ether, lead, lead-oxide, maleic-anhydride, methyl-acetate, methyl-acrylate, methyl-tert-butyl ether, methyl-cellosolve-acetate, methylcyclohexanol, 4,4'-methylenedianiline, monomethylaniline, monomethylhydrazine, nitric-oxide, p-nitroaniline, phenyl-ether, phenyl-ether-biphenyl mixture, phenyl-glycidyl-ether, phenylhydrazine, phosphine, ronnel, sulfuryl-fluoride, talc, tributyl-phosphate, 1,1,2-trichloro-1,2,2-trifluoroethane, trimellitic-anhydride, triorthocresyl-phosphate, triphenyl-phosphate, and vinyl-acetate.

  10. Analytical methods for waste minimisation in the convenience food industry.

    Science.gov (United States)

    Darlington, R; Staikos, T; Rahimifard, S

    2009-04-01

    Waste creation in some sectors of the food industry is substantial, and while much of the used material is non-hazardous and biodegradable, it is often poorly dealt with and simply sent to landfill mixed with other types of waste. In this context, overproduction wastes were found in a number of cases to account for 20-40% of the material wastes generated by convenience food manufacturers (such as ready-meals and sandwiches), often simply just to meet the challenging demands placed on the manufacturer due to the short order reaction time provided by the supermarkets. Identifying specific classes of waste helps to minimise their creation, through consideration of what the materials constitute and why they were generated. This paper aims to provide means by which food industry wastes can be identified, and demonstrate these mechanisms through a practical example. The research reported in this paper investigated the various categories of waste and generated three analytical methods for the support of waste minimisation activities by food manufacturers. The waste classifications and analyses are intended to complement existing waste minimisation approaches and are described through consideration of a case study convenience food manufacturer that realised significant financial savings through waste measurement, analysis and reduction.

  11. A new robust method for the treatment of analytical data

    International Nuclear Information System (INIS)

    Pearton, D.C.G.

    1982-01-01

    A new robust method is proposed for the calculation of the median and the relative standard deviation for a set of data containing unsymmetrically placed outliers. Examples of the advantages of the new method are given, the findings being confirmed by Monte Carlo tests. At Mintek mass-spectrometric data are often unsymmetrical, and all outliers are often at one of the extremities, either all high or all low. In some instances the outliers can be seen visually, and would therefore be rejected on sight. However, when large sets of results are processed, such as those from mass-spectrometric, X-ray fluorescence, and neutron-activation analyses, or in fields such as the assignment of values to reference materials, the sets of results are often too large for visual inspection and are processed within the computer

  12. Analytic comparison of time- and frequency-domain electromagnetic methods

    Energy Technology Data Exchange (ETDEWEB)

    Stoyer, C.H.

    1980-01-01

    The time- and frequency-domain methods of electromagnetic geophysical prospecting are compared to determine the similarities and differences and to recommend system choices for particular field situations. Only the wire-loop configuration is considered, as this array is quite standard in geothermal prospecting. Comparisons are carried out using hardware and physical considerations, a large catalog of 3-layer model curves, 2D-3D model calculations, and by comparing Fourier transforms and layered inversions of field data from the Randsburg KGRA in California. The results generally indicate that frequency-domain methods offer better resolution and more practical hardware design for long-offset shallow applications. They also have a much better backup in terms of modelling tools for interpretation and history of experience. Transient methods are better suited for deeper probing, for both long- and short-offset applications. Frequency-domain methods are limited by the primary field, which is subject to distortion from near-surface inhomogeneites; this is also the case for early-time transients. Transient measurements in late time are limited by ambient electromagnetic noise and dynamic range of receiving equipment.

  13. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  14. Fuel Cycle Externalities: Analytical Methods and Issues, Report 2

    International Nuclear Information System (INIS)

    Barnthouse, L.W.; Cada, G.F.; Cheng, M.-D.; Easterly, C.E.; Kroodsma, R.L.; Lee, R.; Shriner, D.S.; Tolbert, V.R.; Turner, R.S.

    1994-01-01

    that also have not been fully addressed. This document contains two types of papers that seek to fill part of this void. Some of the papers describe analytical methods that can be applied to one of the five steps of the damage function approach. The other papers discuss some of the complex issues that arise in trying to estimate externalities. This report, the second in a series of eight reports, is part of a joint study by the U.S. Department of Energy (DOE) and the Commission of the European Communities (EC)* on the externalities of fuel cycles. Most of the papers in this report were originally written as working papers during the initial phases of this study. The papers provide descriptions of the (non-radiological) atmospheric dispersion modeling that the study uses; reviews much of the relevant literature on ecological and health effects, and on the economic valuation of those impacts; contains several papers on some of the more complex and contentious issues in estimating externalities; and describes a method for depicting the quality of scientific information that a study uses. The analytical methods and issues that this report discusses generally pertain to more than one of the fuel cycles, though not necessarily to all of them. The report is divided into six parts, each one focusing on a different subject area

  15. Estimating Fuel Cycle Externalities: Analytical Methods and Issues, Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Barnthouse, L.W.; Cada, G.F.; Cheng, M.-D.; Easterly, C.E.; Kroodsma, R.L.; Lee, R.; Shriner, D.S.; Tolbert, V.R.; Turner, R.S.

    1994-07-01

    of complex issues that also have not been fully addressed. This document contains two types of papers that seek to fill part of this void. Some of the papers describe analytical methods that can be applied to one of the five steps of the damage function approach. The other papers discuss some of the complex issues that arise in trying to estimate externalities. This report, the second in a series of eight reports, is part of a joint study by the U.S. Department of Energy (DOE) and the Commission of the European Communities (EC)* on the externalities of fuel cycles. Most of the papers in this report were originally written as working papers during the initial phases of this study. The papers provide descriptions of the (non-radiological) atmospheric dispersion modeling that the study uses; reviews much of the relevant literature on ecological and health effects, and on the economic valuation of those impacts; contains several papers on some of the more complex and contentious issues in estimating externalities; and describes a method for depicting the quality of scientific information that a study uses. The analytical methods and issues that this report discusses generally pertain to more than one of the fuel cycles, though not necessarily to all of them. The report is divided into six parts, each one focusing on a different subject area.

  16. Analytical method of waste allocation in waste management systems: Concept, method and case study

    International Nuclear Information System (INIS)

    Bergeron, Francis C.

    2017-01-01

    Waste is not a rejected item to dispose anymore but increasingly a secondary resource to exploit, influencing waste allocation among treatment operations in a waste management (WM) system. The aim of this methodological paper is to present a new method for the assessment of the WM system, the “analytical method of the waste allocation process” (AMWAP), based on the concept of the “waste allocation process” defined as the aggregation of all processes of apportioning waste among alternative waste treatment operations inside or outside the spatial borders of a WM system. AMWAP contains a conceptual framework and an analytical approach. The conceptual framework includes, firstly, a descriptive model that focuses on the description and classification of the WM system. It includes, secondly, an explanatory model that serves to explain and to predict the operation of the WM system. The analytical approach consists of a step-by-step analysis for the empirical implementation of the conceptual framework. With its multiple purposes, AMWAP provides an innovative and objective modular method to analyse a WM system which may be integrated in the framework of impact assessment methods and environmental systems analysis tools. Its originality comes from the interdisciplinary analysis of the WAP and to develop the conceptual framework. AMWAP is applied in the framework of an illustrative case study on the household WM system of Geneva (Switzerland). It demonstrates that this method provides an in-depth and contextual knowledge of WM. - Highlights: • The study presents a new analytical method based on the waste allocation process. • The method provides an in-depth and contextual knowledge of the waste management system. • The paper provides a reproducible procedure for professionals, experts and academics. • It may be integrated into impact assessment or environmental system analysis tools. • An illustrative case study is provided based on household waste

  17. The fitness for purpose of analytical methods applied to fluorimetric uranium determination in water matrix

    International Nuclear Information System (INIS)

    Grinman, Ana; Giustina, Daniel; Mondini, Julia; Diodat, Jorge

    2008-01-01

    Full text: This paper describes the steps which should be followed by a laboratory in order to validate the fluorimetric method for natural uranium in water matrix. The validation of an analytical method is a necessary requirement prior accreditation under Standard norm ISO/IEC 17025, of a non normalized method. Different analytical techniques differ in a sort of variables to be validated. Depending on the chemical process, measurement technique, matrix type, data fitting and measurement efficiency, a laboratory must set up experiments to verify reliability of data, through the application of several statistical tests and by participating in Quality Programs (QP) organized by reference laboratories such as the National Institute of Standards and Technology (NIST), National Physics Laboratory (NPL), or Environmental Measurements Laboratory (EML). However, the participation in QP not only involves international reference laboratories, but also, the national ones which are able to prove proficiency to the Argentinean Accreditation Board. The parameters that the ARN laboratory had to validate in the fluorimetric method to fit in accordance with Eurachem guide and IUPAC definitions, are: Detection Limit, Quantification Limit, Precision, Intra laboratory Precision, Reproducibility Limit, Repeatability Limit, Linear Range and Robustness. Assays to fit the above parameters were designed on the bases of statistics requirements, and a detailed data treatment is presented together with the respective tests in order to show the parameters validated. As a final conclusion, the uranium determination by fluorimetry is a reliable method for direct measurement to meet radioprotection requirements in water matrix, within its linear range which is fixed every time a calibration is carried out at the beginning of the analysis. The detection limit ( depending on blank standard deviation and slope) varies between 3 ug U and 5 ug U which yields minimum detectable concentrations (MDC) of

  18. Analytic Method to Estimate Particle Acceleration in Flux Ropes

    Science.gov (United States)

    Guidoni, S. E.; Karpen, J. T.; DeVore, C. R.

    2015-01-01

    The mechanism that accelerates particles to the energies required to produce the observed high-energy emission in solar flares is not well understood. Drake et al. (2006) proposed a kinetic mechanism for accelerating electrons in contracting magnetic islands formed by reconnection. In this model, particles that gyrate around magnetic field lines transit from island to island, increasing their energy by Fermi acceleration in those islands that are contracting. Based on these ideas, we present an analytic model to estimate the energy gain of particles orbiting around field lines inside a flux rope (2.5D magnetic island). We calculate the change in the velocity of the particles as the flux rope evolves in time. The method assumes a simple profile for the magnetic field of the evolving island; it can be applied to any case where flux ropes are formed. In our case, the flux-rope evolution is obtained from our recent high-resolution, compressible 2.5D MHD simulations of breakout eruptive flares. The simulations allow us to resolve in detail the generation and evolution of large-scale flux ropes as a result of sporadic and patchy reconnection in the flare current sheet. Our results show that the initial energy of particles can be increased by 2-5 times in a typical contracting island, before the island reconnects with the underlying arcade. Therefore, particles need to transit only from 3-7 islands to increase their energies by two orders of magnitude. These macroscopic regions, filled with a large number of particles, may explain the large observed rates of energetic electron production in flares. We conclude that this mechanism is a promising candidate for electron acceleration in flares, but further research is needed to extend our results to 3D flare conditions.

  19. Cleanup standards and pathways analysis methods

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1993-01-01

    Remediation of a radioactively contaminated site requires that certain regulatory criteria be met before the site can be released for unrestricted future use. Since the ultimate objective of remediation is to protect the public health and safety, residual radioactivity levels remaining at a site after cleanup must be below certain preset limits or meet acceptable dose or risk criteria. Release of a decontaminated site requires proof that the radiological data obtained from the site meet the regulatory criteria for such a release. Typically release criteria consist of a composite of acceptance limits that depend on the radionuclides, the media in which they are present, and federal and local regulations. In recent years, the US Department of Energy (DOE) has developed a pathways analysis model to determine site-specific soil activity concentration guidelines for radionuclides that do not have established generic acceptance limits. The DOE pathways analysis computer code (developed by Argonne National Laboratory for the DOE) is called RESRAD (Gilbert et al. 1989). Similar efforts have been initiated by the US Nuclear Regulatory Commission (NRC) to develop and use dose-related criteria based on genetic pathways analyses rather than simplistic numerical limits on residual radioactivity. The focus of this paper is radionuclide contaminated soil. Cleanup standards are reviewed, pathways analysis methods are described, and an example is presented in which RESRAD was used to derive cleanup guidelines

  20. The chemical speciation and analysis of trace elements in sediment with Neutron Activation Analytical method(NAA) and atomic mass spectrometry

    International Nuclear Information System (INIS)

    Nam, Sang-Ho; Kim, Jae-Jin; Chung, Yong-Sam; Kim, Sun-Ha

    2003-01-01

    In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will plan an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA

  1. Materials of the 3.Poznan analytical meeting: The novel methods of samples preparation and analysis of trace amounts of elements

    International Nuclear Information System (INIS)

    1994-01-01

    The conference on Novel Methods of Samples Preparation and Analysis of Trace Amounts of Elements was the eight of succeeding meetings organized annually since 1985 by the Committee of Analytical Chemistry of the Polish Academy of Sciences. The following groups of topics have been extensively discussed: accuracy and precision in trace amounts analysis, sample preparation methods, certification and application of standards and many other topics important for analytical chemistry of trace amount of different elements. Total 43 lectures have been presented in the course of meeting

  2. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  3. Characterization of Catalytic Fast Pyrolysis Oils: The Importance of Solvent Selection for Analytical Method Development

    Energy Technology Data Exchange (ETDEWEB)

    Ferrell, Jack R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ware, Anne E [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-25

    Two catalytic fast pyrolysis (CFP) oils (bottom/heavy fraction) were analyzed in various solvents that are used in common analytical methods (nuclear magnetic resonance - NMR, gas chromatography - GC, gel permeation chromatography - GPC, thermogravimetric analysis - TGA) for oil characterization and speciation. A more accurate analysis of the CFP oils can be obtained by identification and exploitation of solvent miscibility characteristics. Acetone and tetrahydrofuran can be used to completely solubilize CFP oils for analysis by GC and tetrahydrofuran can be used for traditional organic GPC analysis of the oils. DMSO-d6 can be used to solubilize CFP oils for analysis by 13C NMR. The fractionation of oils into solvents that did not completely solubilize the whole oils showed that miscibility can be related to the oil properties. This allows for solvent selection based on physico-chemical properties of the oils. However, based on semi-quantitative comparisons of the GC chromatograms, the organic solvent fractionation schemes did not speciate the oils based on specific analyte type. On the other hand, chlorinated solvents did fractionate the oils based on analyte size to a certain degree. Unfortunately, like raw pyrolysis oil, the matrix of the CFP oils is complicated and is not amenable to simple liquid-liquid extraction (LLE) or solvent fractionation to separate the oils based on the chemical and/or physical properties of individual components. For reliable analyses, for each analytical method used, it is critical that the bio-oil sample is both completely soluble and also not likely to react with the chosen solvent. The adoption of the standardized solvent selection protocols presented here will allow for greater reproducibility of analysis across different users and facilities.

  4. A Review of Extraction and Analytical Methods for the Determination of Tartrazine (E 102) in Foodstuffs.

    Science.gov (United States)

    Rovina, Kobun; Siddiquee, Shafiquzzaman; Shaarani, Sharifudin Md

    2017-07-04

    Tartrazine is an azo food dye, which is orange-colored and water soluble. It is usually used in foods, pharmaceuticals, cosmetics, and textiles. Tartrazine has the potential to cause an adverse health effect on humans, such as hyperactivity in children, allergy, and asthma. Joint FAO/WHO Expert Committee on Food Additive and EU Scientific Committee for Food have standardized the acceptable daily intake for tartrazine that is 7.5 mg kg -1 body weight. Many researchers have detected the presence of tartrazine for monitoring the quality and safety of food products. In this review paper, we highlighted various tartrazine detection and extraction methods. Some of the analytical methods are available such as high-performance liquid chromatography, electrochemical sensor, thin-layer chromatography, spectrophotometry, capillary electrophoresis, and liquid chromatography-tandem mass spectrometry. Also, we discuss following extraction steps: liquid-liquid extraction, solid-phase extraction, membrane filtration, cloud point extraction, and other extraction method. In addition, a brief overview is presented explaining the synthesis process and metabolism of tartrazine and the maximum permitted level in different countries. This review paper will give an insight into different extraction and analytical methods for the determination of tartrazine in healthy foods, which will attract the attention of public toward food safety and quality, and also the interest of food industry and government bodies.

  5. Hanford environmental analytical methods: Methods as of March 1990. Volume 3, Appendix A2-I

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually.

  6. 40 CFR 141.25 - Analytical methods for radioactivity.

    Science.gov (United States)

    2010-07-01

    .... 141.25 Section 141.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Monitoring and Analytical Requirements... Spectrometry 901.1 p. 92 7120, 7120-97 D4785-93, 00a 4.5.2.3 Radioactive Strontium 89, 90 Radiochemical 905.0 p...

  7. Laser: a Tool for Optimization and Enhancement of Analytical Methods

    Energy Technology Data Exchange (ETDEWEB)

    Preisler, Jan [Iowa State Univ., Ames, IA (United States)

    1997-01-01

    In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable determination of plume velocities even when they are very high. Static scattering detection reveals negative influence of particle spallation on MS signal. Ion formation during MALD was monitored using 193-nm light to photodissociate a portion of insulin ion plume. These results define the optimal conditions for desorbing analytes from matrices, as opposed to achieving a compromise between efficient desorption and efficient ionization as is practiced in mass spectrometry. In CE experiment, we examined changes in a poly(ethylene oxide) (PEO) coating by continuously monitoring the electroosmotic flow (EOF) in a fused-silica capillary during electrophoresis. An imaging CCD camera was used to follow the motion of a fluorescent neutral marker zone along the length of the capillary excited by 488-nm Ar-ion laser. The PEO coating was shown to reduce the velocity of EOF by more than an order of magnitude compared to a bare capillary at pH 7.0. The coating protocol was important, especially at an intermediate pH of 7.7. The increase of p

  8. [Molecular epidemiology of infectious diseases: analytical methods and results interpretation].

    Science.gov (United States)

    Sammarco, M L; Ripabelli, G; Tamburro, M

    2014-01-01

    method, especially if used in a hierarchical manner. The interpretation of the molecular results differs according to the typing system's characteristics: for example in the restriction fragments-based analysis, the divergences or the similarity percentages among the profiles are evaluated, whilst the differences in terms of number and intensity of bands are analyzed in the amplification-based approaches. Moreover, a correct interpretation of molecular results significantly depends by other critical factors, such as the comprehension of the typing system and data quality, the microbial diversity, and the epidemiological context in which the method is used. The analysis of PFGE data, considered as the "gold standard", is based on the differences of the number and position of bands patterns, although recent recommendations are now available from the Centers for Diseases Control and Prevention (CDC) for a more accurate interpretation, which also include the evaluation of the gel quality, the genetic diversity of the microorganism, the time and geographical scale of an epidemic event. Future advances in the molecular typing technologies indeed will provide rapid methodological improvements, such as a greater degree of automation, better resolution, higher throughput, and a greater availability of dedicated bioinformatics tools. These factors will all contribute to an increasing application of genotyping methods to better understand the epidemiology of infectious diseases, and to implement, along with the strengthened international and interdisciplinary partnerships, more effective control and prevention strategies for Public Health improvements.

  9. Sulfathiazole: analytical methods for quantification in seawater and macroalgae.

    Science.gov (United States)

    Leston, Sara; Nebot, Carolina; Nunes, Margarida; Cepeda, Alberto; Pardal, Miguel Ângelo; Ramos, Fernando

    2015-01-01

    The awareness of the interconnection between pharmaceutical residues, human health, and aquaculture has highlighted the concern with the potential harmful effects it can induce. Furthermore, to better understand the consequences more research is needed and to achieve that new methodologies on the detection and quantification of pharmaceuticals are necessary. Antibiotics are a major class of drugs included in the designation of emerging contaminants, representing a high risk to natural ecosystems. Among the most prescribed are sulfonamides, with sulfathiazole being the selected compound to be investigated in this study. In the environment, macroalgae are an important group of producers, continuously exposed to contaminants, with a significant role in the trophic web. Due to these characteristics are already under scope for the possibility of being used as bioindicators. The present study describes two new methodologies based on liquid chromatography for the determination of sulfathiazole in seawater and in the green macroalgae Ulva lactuca. Results show both methods were validated according to international standards, with MS/MS detection showing more sensitivity as expected with LODs of 2.79ng/g and 1.40ng/mL for algae and seawater, respectively. As for UV detection the values presented were respectively 2.83μg/g and 2.88μg/mL, making it more suitable for samples originated in more contaminated sites. The methods were also applied to experimental data with success with results showing macroalgae have potential use as indicators of contamination. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Methods used by Elsam for monitoring precision and accuracy of analytical results

    Energy Technology Data Exchange (ETDEWEB)

    Hinnerskov Jensen, J. [Soenderjyllands Hoejspaendingsvaerk, Faelleskemikerne, Aabenraa (Denmark)

    1996-12-01

    Performing round robins at regular intervals is the primary method used by ELsam for monitoring precision and accuracy of analytical results. The firs round robin was started in 1974, and today 5 round robins are running. These are focused on: boiler water and steam, lubricating oils, coal, ion chromatography and dissolved gases in transformer oils. Besides the power plant laboratories in Elsam, the participants are power plant laboratories from the rest of Denmark, industrial and commercial laboratories in Denmark, and finally foreign laboratories. The calculated standard deviations or reproducibilities are compared with acceptable values. These values originate from ISO, ASTM and the like, or from own experiences. Besides providing the laboratories with a tool to check their momentary performance, the round robins are vary suitable for evaluating systematic developments on a long term basis. By splitting up the uncertainty according to methods, sample preparation/analysis, etc., knowledge can be extracted from the round robins for use in many other situations. (au)

  11. INTEGRATING DATA ANALYTICS AND SIMULATION METHODS TO SUPPORT MANUFACTURING DECISION MAKING.

    Science.gov (United States)

    Kibira, Deogratias; Hatim, Qais; Kumara, Soundar; Shao, Guodong

    2015-12-01

    Modern manufacturing systems are installed with smart devices such as sensors that monitor system performance and collect data to manage uncertainties in their operations. However, multiple parameters and variables affect system performance, making it impossible for a human to make informed decisions without systematic methodologies and tools. Further, the large volume and variety of streaming data collected is beyond simulation analysis alone. Simulation models are run with well-prepared data. Novel approaches, combining different methods, are needed to use this data for making guided decisions. This paper proposes a methodology whereby parameters that most affect system performance are extracted from the data using data analytics methods. These parameters are used to develop scenarios for simulation inputs; system optimizations are performed on simulation data outputs. A case study of a machine shop demonstrates the proposed methodology. This paper also reviews candidate standards for data collection, simulation, and systems interfaces.

  12. THE QuEChERS ANALYTICAL METHOD COMBINED WITH LOW ...

    African Journals Online (AJOL)

    Working standard solutions were prepared from the mixed intermediate standard solution by .... To this end, six organic solvents, with their densities given in parentheses, including dihexyl ether (0.785 g mL-1) ..... in cereals and dry animal feed using gas chromatography-tandem quadrupole mass spectrometry revisited.

  13. Standardization of methods of maxillofacial roentgenology

    International Nuclear Information System (INIS)

    Rabukhina, N.A.; Arzhantsev, A.P.; Chikirdin, Eh.G.; Tombak, M.I.; Stavitskij, R.V.; Vasil'ev, Yu.D.

    1989-01-01

    Typical errors in teeth roentgenography reproduced in experiment, indicate that considerable disproportional distortions of images of anatomical structures which are decisive for radiodiagnosis, may occur in these cases. Standardization of intraoral roentgenography is based on a strict position of the patient's head, angle of inclination and alignment of a tube. Specialized R3-1 film should be used

  14. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  15. Introduction to Validation of Analytical Methods: Potentiometric Determination of CO[subscript 2

    Science.gov (United States)

    Hipólito-Nájera, A. Ricardo; Moya-Hernandez, M. Rosario; Gomez-Balderas, Rodolfo; Rojas-Hernandez, Alberto; Romero-Romo, Mario

    2017-01-01

    Validation of analytical methods is a fundamental subject for chemical analysts working in chemical industries. These methods are also relevant for pharmaceutical enterprises, biotechnology firms, analytical service laboratories, government departments, and regulatory agencies. Therefore, for undergraduate students enrolled in majors in the field…

  16. A comparison between analytic and numerical methods for modelling automotive dissipative silencers with mean flow

    Science.gov (United States)

    Kirby, R.

    2009-08-01

    Identifying an appropriate method for modelling automotive dissipative silencers normally requires one to choose between analytic and numerical methods. It is common in the literature to justify the choice of an analytic method based on the assumption that equivalent numerical techniques are more computationally expensive. The validity of this assumption is investigated here, and the relative speed and accuracy of two analytic methods are compared to two numerical methods for a uniform dissipative silencer that contains a bulk reacting porous material separated from a mean gas flow by a perforated pipe. The numerical methods are developed here with a view to speeding up transmission loss computation, and are based on a mode matching scheme and a hybrid finite element method. The results presented demonstrate excellent agreement between the analytic and numerical models provided a sufficient number of propagating acoustic modes are retained. However, the numerical mode matching method is shown to be the fastest method, significantly outperforming an equivalent analytic technique. Moreover, the hybrid finite element method is demonstrated to be as fast as the analytic technique. Accordingly, both numerical techniques deliver fast and accurate predictions and are capable of outperforming equivalent analytic methods for automotive dissipative silencers.

  17. Antibody reactions methods in safety standards

    International Nuclear Information System (INIS)

    Shubik, V.M.; Sirasdinov, V.G.; Zasedatelev, A.A.; Kal'nitskij, S.A.; Livshits, R.E.

    1978-01-01

    Results of determinations are presented of autoantibodies in white rats to which the radionuclides 137 Cs, 226 Ra, and 90 Sr that show different distribution patterns in the body, have been administered chronically. Autoantiboby production is found to increase when the absorbed doses are close to or exceeding seven- to tenfold the maximum permissible values. The results obtained point to the desirability of autoantibody determination in studies aimed at setting hygienic standards for the absorption of radioactive substances

  18. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    Science.gov (United States)

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient

  19. Analytical Method (M) - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Metabol...lsdba.nbdc01324-003 Description of data contents Information about methods of instrumental analysis. Data file File name: metabol...onote_analytical_method.zip File URL: ftp://ftp.biosciencedbc.jp/archive/metabolonote/LATEST/metabol...://togodb.biosciencedbc.jp/togodb/view/metabolonote_analytical_method#en Data acquisition method - Data anal...his Database Site Policy | Contact Us Analytical Method (M) - Metabolonote | LSDB Archive ...

  20. A manual of analytical methods used at MINTEK

    International Nuclear Information System (INIS)

    Stoch, H.; Dixon, K.

    1983-01-01

    The manual deals with various methods for a wide range of elemental analysis. Some of the methods that are used, include atomic absorption spectroscopy, optical emission spectroscopy and x-ray fluoresence spectroscopy. The basic charateristics of the method are given and the procedures are recorded step by step. One of the sections deals with methods associated with the recovery of uranium

  1. Multicriteria evaluation of power plants impact on the living standard using the analytic hierarchy process

    International Nuclear Information System (INIS)

    Chatzimouratidis, Athanasios I.; Pilavachi, Petros A.

    2008-01-01

    The purpose of this study is to evaluate 10 types of power plants available at present including fossil fuel, nuclear as well as renewable-energy-based power plants, with regard to their overall impact on the living standard of local communities. Both positive and negative impacts of power plant operation are considered using the analytic hierarchy process (AHP). The current study covers the set of criteria weights considered typical for many local communities in many developed countries. The results presented here are illustrative only and user-defined weighting is required to make this study valuable for a specific group of users. A sensitivity analysis examines the most important weight variations, thus giving an overall view of the problem evaluation to every decision maker. Regardless of criteria weight variations, the five types of renewable energy power plant rank in the first five positions. Nuclear plants are in the sixth position when priority is given to quality of life and last when socioeconomic aspects are valued more important. Natural gas, oil and coal/lignite power plants rank between sixth and tenth position having slightly better ranking under priority to socioeconomic aspects

  2. Standardization of C-14 by tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Koskinas, Marina F.; Kuznetsova, Maria; Yamazaki, Ione; Brancaccio, Franco; Dias, Mauro S., E-mail: koskinas@ipen.br, E-mail: marysmith@usp.br, E-mail: yamazaki@ipen.br, E-mail: fbrancac@ipen.br, E-mail: msdias@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The standardization of a {sup 14}C radioactive solution by means of the efficiency tracing technique is described. The {sup 14}C is a beta pure emitter with endpoint energy of 156 keV decaying to the ground state of {sup 14}N. The activity measurement was performed in a 4πβ-γ coincidence system, measuring the pure beta emitter mixed with a beta gamma emitter, which provides the beta detection efficiency. The radionuclide {sup 60}Co, which decays by beta particle followed by two gamma rays, was used as tracer and the efficiency was obtained by selecting the 1173 keV plus 1332 keV total energy absorption peak at the gamma channel. Known aliquots of the tracer, previously standardized by 4πβ (PC)-γ coincidence, were mixed with known aliquots of {sup 14}C. The sources of {sup 14}C + {sup 60}Co were prepared by dropping known aliquots from each radioactive solution. The events were registered by a Software Coincidence System (SCS). The activity of the solution was determined by using the extrapolation technique, changing the beta efficiency by pulse height discrimination. In order to determine the final activity, a Monte Carlo simulation was used to calculate the extrapolation curve. All the uncertainties involved were treated rigorously, by means of the covariance analysis methodology. Measurements using a HIDEX, a commercial liquid scintillator system, were carried out and the results were compared with the tracing technique, showing a good agreement. (author)

  3. Intercalibration of analytical methods on marine environmental samples

    International Nuclear Information System (INIS)

    1985-10-01

    The analytical results reported by the 55 laboratories from 29 countries participating in this intercomparison have enabled to certify the concentration of 16 elements (As, Br, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Na, Rb, Se, Sr, Zn) in the mussel homogenate MA-M-2/TM. Information values could be established for 6 additional elements (Ag, Au, Cl, Pb, Sb, Sc). The atomic absorption spectroscopy was predominantly used in this intercomparison (45% of all determinations). It was followed by neutron activation analysis (28%), atomic emission spectroscopy (15%) and X-ray fluorescence (5%). The total number of outliers was moderate: 11.7% of all results. The number of outlying results by participating laboratories varied between 0 and 6

  4. Establishing the analytical procedure for acetate in water by ion chromatography method

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh

    2015-01-01

    In recent studies of contamination sources of arsenic, ammonium, iron, organic carbon in groundwater, acetate is measured a lot because it is the main decomposition product of organic compounds from sediment into groundwater. In order to better support for the study of the origin and mobilization mechanism of the pollutants, acetate was studied analysis method in Isotopes Hydrology Laboratory using ion chromatography technique. Project Researchers used Ion Chromatography system - DX-600 including IonPac ICE-AS1 column for separating acetate and conductivity detector CD 25 to quantify acetate in water samples. The study results showed that project team has successfully developed analytical procedures of acetate in water with acetate’s retention time is 12 minutes, limit of detection (LOD) of the method was 0.01 ppm. The accuracy of the method was established by calculating the precision and bias of 10 analysis times of a standard sample at content levels 1 ppm and 8 ppm. The results of the 10 measurements are satisfiable about precision and bias with repeated standard deviation coefficient CVR were 1.3% and 0.2% and the recoveries R were 99.92% and 101.72%. (author)

  5. Standard Testing Methods for Satellite Communication Systems

    OpenAIRE

    Stoner, Jerry

    2005-01-01

    University space programs continue to push the envelope of small satellite technology. Because budgets are often limited, and equipment costs can often be prohibitive to even well-established space programs, it becomes necessary to maximize the benefit/cost ratio of testing methods. Expensive testing is often not an option, nor is it realistic. Traditional methods such as anechoic chambers or antenna test ranges are not options, and testing the craft on the ground is not practical. Because of...

  6. Does leaf chemistry differentially affect breakdown in tropical versus temperate streams? Importance of standardized analytical techniques to measure leaf chemistry

    Science.gov (United States)

    Marcelo Ardon; Catherine M. Pringle; Susan L. Eggert

    2009-01-01

    Comparisons of the effects of leaf litter chemistry on leaf breakdown rates in tropical vs temperate streams are hindered by incompatibility among studies and across sites of analytical methods used to...

  7. Assessing the service quality of Iran military hospitals: Joint Commission International standards and Analytic Hierarchy Process (AHP) technique.

    Science.gov (United States)

    Bahadori, Mohammadkarim; Ravangard, Ramin; Yaghoubi, Maryam; Alimohammadzadeh, Khalil

    2014-01-01

    Military hospitals are responsible for preserving, restoring and improving the health of not only armed forces, but also other people. According to the military organizations strategy, which is being a leader and pioneer in all areas, providing quality health services is one of the main goals of the military health care organizations. This study was aimed to evaluate the service quality of selected military hospitals in Iran based on the Joint Commission International (JCI) standards and comparing these hospitals with each other and ranking them using the analytic hierarchy process (AHP) technique in 2013. This was a cross-sectional and descriptive study conducted on five military hospitals, selected using the purposive sampling method, in 2013. Required data collected using checklists of accreditation standards and nominal group technique. AHP technique was used for prioritizing. Furthermore, Expert Choice 11.0 was used to analyze the collected data. Among JCI standards, the standards of access to care and continuity of care (weight = 0.122), quality improvement and patient safety (weight = 0.121) and leadership and management (weight = 0.117) had the greatest importance, respectively. Furthermore, in the overall ranking, BGT (weight = 0.369), IHM (0.238), SAU (0.202), IHK (weight = 0.125) and SAB (weight = 0.066) ranked first to fifth, respectively. AHP is an appropriate technique for measuring the overall performance of hospitals and their quality of services. It is a holistic approach that takes all hospital processes into consideration. The results of the present study can be used to improve hospitals performance through identifying areas, which are in need of focus for quality improvement and selecting strategies to improve service quality.

  8. Investigation by perturbative and analytical method of electronic properties of square quantum well under electric field

    Directory of Open Access Journals (Sweden)

    Mustafa Kemal BAHAR

    2010-06-01

    Full Text Available In this study, the effects of applied electric field on the isolated square quantum well was investigated by analytic and perturbative method. The energy eigen values and wave functions in quantum well were found by perturbative method. Later, the electric field effects were investigated by analytic method, the results of perturbative and analytic method were compared. As well as both of results fit with each other, it was observed that externally applied electric field changed importantly electronic properties of the system.

  9. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  10. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    HP

    Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with copper. Method: A coloured complex based on UV/Vis spectroscopic method was developed for the determination of losartan potassium concentration in pharmaceutical ...

  11. Method for Constructing Standardized Simulated Root Canals.

    Science.gov (United States)

    Schulz-Bongert, Udo; Weine, Franklin S.

    1990-01-01

    The construction of visual and manipulative aids, clear resin blocks with root-canal-like spaces, for simulation of root canals is explained. Time, materials, and techniques are discussed. The method allows for comparison of canals, creation of any configuration of canals, and easy presentation during instruction. (MSE)

  12. Application of an analytical method for solution of thermal hydraulic conservation equations

    Energy Technology Data Exchange (ETDEWEB)

    Fakory, M.R. [Simulation, Systems & Services Technologies Company (S3 Technologies), Columbia, MD (United States)

    1995-09-01

    An analytical method has been developed and applied for solution of two-phase flow conservation equations. The test results for application of the model for simulation of BWR transients are presented and compared with the results obtained from application of the explicit method for integration of conservation equations. The test results show that with application of the analytical method for integration of conservation equations, the Courant limitation associated with explicit Euler method of integration was eliminated. The results obtained from application of the analytical method (with large time steps) agreed well with the results obtained from application of explicit method of integration (with time steps smaller than the size imposed by Courant limitation). The results demonstrate that application of the analytical approach significantly improves the numerical stability and computational efficiency.

  13. Critical assessment of three high performance liquid chromatography analytical methods for food carotenoid quantification.

    Science.gov (United States)

    Dias, M Graça; Oliveira, Luísa; Camões, M Filomena G F C; Nunes, Baltazar; Versloot, Pieter; Hulshof, Paul J M

    2010-05-21

    Three sets of extraction/saponification/HPLC conditions for food carotenoid quantification were technically and economically compared. Samples were analysed for carotenoids alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein, lycopene, and zeaxanthin. All methods demonstrated good performance in the analysis of a composite food standard reference material for the analytes they are applicable to. Methods using two serial connected C(18) columns and a mobile phase based on acetonitrile, achieved a better carotenoid separation than the method using a mobile phase based on methanol and one C(18)-column. Carotenoids from leafy green vegetable matrices appeared to be better extracted with a mixture of methanol and tetrahydrofuran than with tetrahydrofuran alone. Costs of carotenoid determination in foods were lower for the method with mobile phase based on methanol. However for some food matrices and in the case of E-Z isomer separations, this was not technically satisfactory. Food extraction with methanol and tetrahydrofuran with direct evaporation of these solvents, and saponification (when needed) using pyrogallol as antioxidant, combined with a HPLC system using a slight gradient mobile phase based on acetonitrile and a stationary phase composed by two serial connected C(18) columns was the most technically and economically favourable method. 2010. Published by Elsevier B.V.

  14. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  15. Application of multi attribute failure mode analysis of milk production using analytical hierarchy process method

    Science.gov (United States)

    Rucitra, A. L.

    2018-03-01

    Pusat Koperasi Induk Susu (PKIS) Sekar Tanjung, East Java is one of the modern dairy industries producing Ultra High Temperature (UHT) milk. A problem that often occurs in the production process in PKIS Sekar Tanjung is a mismatch between the production process and the predetermined standard. The purpose of applying Analytical Hierarchy Process (AHP) was to identify the most potential cause of failure in the milk production process. Multi Attribute Failure Mode Analysis (MAFMA) method was used to eliminate or reduce the possibility of failure when viewed from the failure causes. This method integrates the severity, occurrence, detection, and expected cost criteria obtained from depth interview with the head of the production department as an expert. The AHP approach was used to formulate the priority ranking of the cause of failure in the milk production process. At level 1, the severity has the highest weight of 0.41 or 41% compared to other criteria. While at level 2, identifying failure in the UHT milk production process, the most potential cause was the average mixing temperature of more than 70 °C which was higher than the standard temperature (≤70 ° C). This failure cause has a contributes weight of 0.47 or 47% of all criteria Therefore, this study suggested the company to control the mixing temperature to minimise or eliminate the failure in this process.

  16. An Analytical Method for Measuring Competence in Project Management

    Science.gov (United States)

    González-Marcos, Ana; Alba-Elías, Fernando; Ordieres-Meré, Joaquín

    2016-01-01

    The goal of this paper is to present a competence assessment method in project management that is based on participants' performance and value creation. It seeks to close an existing gap in competence assessment in higher education. The proposed method relies on information and communication technology (ICT) tools and combines Project Management…

  17. Analytical Method Details (MS) - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Metabol...l Analysis information). Data file File name: metabolonote_analytical_method_details.zip File URL: ftp://ftp....biosciencedbc.jp/archive/metabolonote/LATEST/metabolonote_analytical_method_details.zip File size: 73 KB Si...mple search URL http://togodb.biosciencedbc.jp/togodb/view/metabolonote_analytica...cription Download License Update History of This Database Site Policy | Contact Us Analytical Method Details (MS) - Metabolonote | LSDB Archive ...

  18. Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501.

    Science.gov (United States)

    Supak Smolcic, Vesna; Bilic-Zulle, Lidija; Fisic, Elizabeta

    2011-01-01

    Cobas 6000 (Roche, Germany) is biochemistry analyzer for spectrophotometric, immunoturbidimetric and ion-selective determination of biochemical analytes. Hereby we present analytical validation with emphasis on method performance judgment for routine operation. Validation was made for 30 analytes (metabolites, enzymes, trace elements, specific proteins and electrolytes). Research included determination of within-run (N = 20) and between-run imprecision (N = 30), inaccuracy (N = 30) and method comparison with routine analyzer (Beckman Coulter AU640) (N = 50). For validation of complete analytical process we calculated total error (TE). Results were judged according to quality specification criteria given by European Working Group. Within-run imprecision CVs were all below 5% except for cholesterol, triglycerides, IgA and IgM. Between-run CVs for all analytes were below 10%. Analytes that did not meet the required specifications for imprecision were: total protein, albumin, calcium, sodium, chloride, immunoglobulins and HDL cholesterol. Analytes that did not fulfill requirements for inaccuracy were: total protein, calcium, sodium and chloride. Analytes that deviated from quality specifications for total error were: total protein, albumin, calcium, sodium, chloride and IgM. Passing-Bablok regression analysis provided linear equation and 95% confidence interval for intercept and slope. Complete accordance with routine analyzer Beckman Coulter AU640 showed small number of analytes. Other analytes showed small proportional and/or small constant difference and therefore need to be adjusted for routine operation. Regarding low CV values, tested analyzer has satisfactory accuracy and precision and is extremely stable. Except for analytes that are coherent on both analyzers, some analytes require adjustments of slope and intercept for complete accordance.

  19. Standardization of 57Co using different methods of LNMRI

    International Nuclear Information System (INIS)

    Rezende, E.A.; Lopes, R.T.; Silva, C.J. da; Poledna, R.; Silva, R.L. da; Tauhata, L.

    2015-01-01

    The activity of a 57 Co solution was determined using four LNMRI different measurement methods. The solution was standardized by live-timed anti-coincidence method and sum-peak method. The efficiency curve and standard-sample comparison methods were also used in this comparison. The results and their measurement uncertainties demonstrating the equivalence of these methods. As an additional contribution, the gamma emission probabilities of 57 Co were also determined. (author)

  20. Analytic method for calculating properties of random walks on networks

    Science.gov (United States)

    Goldhirsch, I.; Gefen, Y.

    1986-01-01

    A method for calculating the properties of discrete random walks on networks is presented. The method divides complex networks into simpler units whose contribution to the mean first-passage time is calculated. The simplified network is then further iterated. The method is demonstrated by calculating mean first-passage times on a segment, a segment with a single dangling bond, a segment with many dangling bonds, and a looplike structure. The results are analyzed and related to the applicability of the Einstein relation between conductance and diffusion.

  1. Standard methods for analysis of phosphorus-32

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Methods are described for the determination of the radiochemical purity and the absolute disintegration rate of 32 P radioisotope preparations. The 32 P activity is determined by β counting, and other low-energy β radioactive contaminants are determined by aluminum-absorption curve data. Any γ-radioactive contaminants are determined by γ counting. Routine chemical testing is used to establish the chemical characteristics. The presence or absence of heavy metals is established by spot tests; free acid is determined by use of a pH meter; total solids are determined gravimetrically by evaporation and ignition at a temperature sufficient to evaporate the mineral acids, HCl and HNO 3 ; and nonvolatile matter, defined as that material which does not evaporate or ignite at a temperature sufficient to convert C to CO or CO 2 , is determined gravimetrically after such ignition

  2. Miscellaneous standard methods for Apis mellifera research

    DEFF Research Database (Denmark)

    Human, Hannelie; Brodschneider, Robert; Dietemann, Vincent

    2013-01-01

    and storing as well as determining individual weight of bees. The precise timing of developmental stages is also an important aspect of sampling individuals for experiments. In order to investigate and manipulate functional processes in honey bees, e. g. memory formation and retrieval and gene expression......, microinjection is often used. A method that is used by both researchers and beekeepers is the marking of queens that serves not only to help to locate her during her life, but also enables the dating of queens. Creating multiple queen colonies allows the beekeeper to maintain spare queens, increase brood...... production or ask questions related to reproduction. On colony level, very useful techniques are the measurement of intra hive mortality using dead bee traps, weighing of full hives, collecting pollen and nectar, and digital monitoring of brood development via location recognition. At the population level...

  3. Analytical Evaluation of Beam Deformation Problem Using Approximate Methods

    DEFF Research Database (Denmark)

    Barari, Amin; Kimiaeifar, A.; Domairry, G.

    2010-01-01

    The beam deformation equation has very wide applications in structural engineering. As a differential equation, it has its own problem concerning existence, uniqueness and methods of solutions. Often, original forms of governing differential equations used in engineering problems are simplified...

  4. 40 CFR 136.6 - Method modifications and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... must be dechlorinated prior to the addition of such salts. (iii) If the characteristics of a wastewater... matrices; as described in the ATP Protocol, after validation in nine distinct matrices, the method may be...

  5. EVALUATION OF ANALYTICAL METHODS FOR DETERMINING PESTICIDES IN BABY FOOD

    Science.gov (United States)

    Three extraction methods and two detection techniques for determining pesticides in baby food were evaluated. The extraction techniques examined were supercritical fluid extraction (SFE), enhanced solvent extraction (ESE), and solid phase extraction (SPE). The detection techni...

  6. The contribution of analytical detection methods to the enforcement of good irradiation practice

    International Nuclear Information System (INIS)

    Ehlermann, D.A.E.

    1996-01-01

    Good Manufacturing Practice (GMP) is a generally accepted principle combining several features in order to achieve the optimal quality. In other words, GMP is observed if every possible measure is taken to contribute to the best possible quality of the end product. In this sense, Good Irradiation Practice (GIP) may be understood as one of the many elements of GMP dealing especially with aspects of processing food using ionising radiation. On the contrary the operator of an irradiation facility may consider GIP as the central idea including that GMP - in this case excluding the radiation aspects - is observed in addition to GIP standards. Regardless of this theoretical dispute, it is obvious that food irradiation requires classical GMP to be applied without exception and that good practice is also applied in radiation processing. The main interest in analytical methods for the identification of radiation processed food arose from the need to enforce the ban on this process, to verify correct labelling, or to ensure that it is used only for the very limited number of application which are permitted. In this field, identification methods already introduced into the official food inspection systems have contributed considerably towards making evident several cases of the fraudulent application of radiation processing. At present, as radiation processing of food is becoming more and more accepted, the number of national clearances is increasing and the European Community is preparing for a Directive to harmonise the food laws of the member states with regard to food irradiation. Therefore, it should be considered how the analytical detection methods which have been developed could contribute to enforcing good manufacturing practices, once the main goal ceases to be the suppression of this process. (author)

  7. Analytical method by high resolution liquid chromatography for the determination of carbamazepine in human plasma

    International Nuclear Information System (INIS)

    Jimenez Aleman, Narda M; Calero Carbonell, Jorge E; Padron Yaquis, Alejandro S; Izquierdo Lozano, Julio C

    2007-01-01

    One of the requirements to develop the studies of bioavailability and bioequivalence is to have analytic methodologies validated for the work with samples in biological fluids. A method was developed by high resolution liquid chromatography for the determination of carbamazepine in human plasma. A mixture of hydrogen phosphate of sodium: acetonitrile (65:35) adjusted to pH= 3.3 with phosphoric acid, flow of 1.2 mL/min and ultraviolet detection at 210 nm, was used as mobile phase. Propylparabene was used as an internal standard. According to the established regulations for the validation of the methods in biological fluids, the following parameters were studied: stability of the samples, lineality, specificity, precision, accuracy and limit of detection and quantification. The method proved to be specific and sensitive with a detection and quantification limit of 0.9 and 1.0 ng, respectively. The method was lineal, precise and exact in the range of concentrations of 1. 07 at 12.67 μg/mL. The mean recovery was not statistically different from 100.0 %. The analito in the proposed biological matrix remained in the studied period. The methodology described in this work is applied in our case to the study that evaluates the bioavailability and bioequivalence of a Cuban formulation of carbamazepine in healthy volunteers. (Author)

  8. Analytical chemistry

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The division for Analytical Chemistry continued to try and develope an accurate method for the separation of trace amounts from mixtures which, contain various other elements. Ion exchange chromatography is of special importance in this regard. New separation techniques were tried on certain trace amounts in South African standard rock materials and special ceramics. Methods were also tested for the separation of carrier-free radioisotopes from irradiated cyclotron discs

  9. Cluster Analytical Method of Fault Risk Analysis in Systems

    Science.gov (United States)

    Michaľčonok, German; Horalová Kalinová, Michaela

    2016-12-01

    In providing safety functions, the proposal of safety functions of control systems is an important part of a risk reduction strategy. In the specification of security requirements, it is necessary to determine and document individual characteristics and the desired performance level for each safety. This article presents the results of the experiment cluster analysis. The results of the experiment prove that the methods of cluster analysis provide a suitable tool for analyzing the reliability of safety systems analysis. Regarding the increasing complexity of the systems, we can state that the application of these methods in the subject area is a good choice.

  10. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  11. An Analytical framework of social learning facilitated by participatory methods

    NARCIS (Netherlands)

    Scholz, G.; Dewulf, A.; Pahl-Wostl, C.

    2014-01-01

    Social learning among different stakeholders is often a goal in problem solving contexts such as environmental management. Participatory methods (e.g., group model-building and role playing games) are frequently assumed to stimulate social learning. Yet understanding if and why this assumption is

  12. Analytic Method for Pressure Recovery in Truncated Diffusers ...

    African Journals Online (AJOL)

    A prediction method is presented for the static pressure recovery in subsonic axisymmetric truncated conical diffusers. In the analysis, a turbulent boundary layer is assumed at the diffuser inlet and a potential core exists throughout the flow. When flow separation occurs, this approach cannot be used to predict the maximum ...

  13. Approximate Analytic Solutions for the Two-Phase Stefan Problem Using the Adomian Decomposition Method

    Directory of Open Access Journals (Sweden)

    Xiao-Ying Qin

    2014-01-01

    Full Text Available An Adomian decomposition method (ADM is applied to solve a two-phase Stefan problem that describes the pure metal solidification process. In contrast to traditional analytical methods, ADM avoids complex mathematical derivations and does not require coordinate transformation for elimination of the unknown moving boundary. Based on polynomial approximations for some known and unknown boundary functions, approximate analytic solutions for the model with undetermined coefficients are obtained using ADM. Substitution of these expressions into other equations and boundary conditions of the model generates some function identities with the undetermined coefficients. By determining these coefficients, approximate analytic solutions for the model are obtained. A concrete example of the solution shows that this method can easily be implemented in MATLAB and has a fast convergence rate. This is an efficient method for finding approximate analytic solutions for the Stefan and the inverse Stefan problems.

  14. Non-standard photography methods in audiovisual journalism

    OpenAIRE

    Géla, František

    2015-01-01

    The aim of the diploma thesis "Non- standard photography methods in audiovisual journalism" is to present image and production methods that are used in television news and journalism - particularly those ones that defy standard methods. These methods appear, considering technological development and the endeavour of making neutral visual space of television journalism, more attractive. First chapter of the thesis presents television news, its history, characteristics, elements and typology of...

  15. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    Science.gov (United States)

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed.

  16. A method of calculating the Jost function for analytic potentials

    International Nuclear Information System (INIS)

    Rakityansky, S.A.; Amos, K.

    1995-01-01

    A combination of the variable-constant and complex coordinate rotation methods is used to solve the two-body Schroedinger equation. The equation is replaced by a system of linear first-order differential equations, which enables one to perform direct calculation of the Jost function for all complex momenta of physical interest including the spectral points corresponding to bound and resonance states. 16 refs., 2 tabs., 2 figs

  17. Diclofenac quantification: analytical attributes of a spectrophotometric method

    OpenAIRE

    Monzón, Celina M.; Delfino, Mario R.; Sarno, María del C.; Delfino, Mario R. (h)

    2011-01-01

    An spectrophotometric UV-visible technique used to quantify diclofenac and its application to pharmaceutical preparations is described, based on diclofenac oxidation by Fe(III) in the presence of ophenanthroline. The formation of tris (o-phenanthroline)-Fe(II) complex (ferroin) upon diclofenac reaction was investigated. Absorbance of ferroin complex was measured at 506 nm. This method was tested on 50 mg tablets. Operating with placebos, it was found that excipients do not interfere with the ...

  18. Analytical methods applied to diverse types of Brazilian propolis

    Directory of Open Access Journals (Sweden)

    Marcucci Maria

    2011-06-01

    Full Text Available Abstract Propolis is a bee product, composed mainly of plant resins and beeswax, therefore its chemical composition varies due to the geographic and plant origins of these resins, as well as the species of bee. Brazil is an important supplier of propolis on the world market and, although green colored propolis from the southeast is the most known and studied, several other types of propolis from Apis mellifera and native stingless bees (also called cerumen can be found. Propolis is usually consumed as an extract, so the type of solvent and extractive procedures employed further affect its composition. Methods used for the extraction; analysis the percentage of resins, wax and insoluble material in crude propolis; determination of phenolic, flavonoid, amino acid and heavy metal contents are reviewed herein. Different chromatographic methods applied to the separation, identification and quantification of Brazilian propolis components and their relative strengths are discussed; as well as direct insertion mass spectrometry fingerprinting. Propolis has been used as a popular remedy for several centuries for a wide array of ailments. Its antimicrobial properties, present in propolis from different origins, have been extensively studied. But, more recently, anti-parasitic, anti-viral/immune stimulating, healing, anti-tumor, anti-inflammatory, antioxidant and analgesic activities of diverse types of Brazilian propolis have been evaluated. The most common methods employed and overviews of their relative results are presented.

  19. Analytical models approximating individual processes: a validation method.

    Science.gov (United States)

    Favier, C; Degallier, N; Menkès, C E

    2010-12-01

    Upscaling population models from fine to coarse resolutions, in space, time and/or level of description, allows the derivation of fast and tractable models based on a thorough knowledge of individual processes. The validity of such approximations is generally tested only on a limited range of parameter sets. A more general validation test, over a range of parameters, is proposed; this would estimate the error induced by the approximation, using the original model's stochastic variability as a reference. This method is illustrated by three examples taken from the field of epidemics transmitted by vectors that bite in a temporally cyclical pattern, that illustrate the use of the method: to estimate if an approximation over- or under-fits the original model; to invalidate an approximation; to rank possible approximations for their qualities. As a result, the application of the validation method to this field emphasizes the need to account for the vectors' biology in epidemic prediction models and to validate these against finer scale models. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. A Vocal-Based Analytical Method for Goose Behaviour Recognition

    Directory of Open Access Journals (Sweden)

    Henrik Karstoft

    2012-03-01

    Full Text Available Since human-wildlife conflicts are increasing, the development of cost-effective methods for reducing damage or conflict levels is important in wildlife management. A wide range of devices to detect and deter animals causing conflict are used for this purpose, although their effectiveness is often highly variable, due to habituation to disruptive or disturbing stimuli. Automated recognition of behaviours could form a critical component of a system capable of altering the disruptive stimuli to avoid this. In this paper we present a novel method to automatically recognise goose behaviour based on vocalisations from flocks of free-living barnacle geese (Branta leucopsis. The geese were observed and recorded in a natural environment, using a shielded shotgun microphone. The classification used Support Vector Machines (SVMs, which had been trained with labeled data. Greenwood Function Cepstral Coefficients (GFCC were used as features for the pattern recognition algorithm, as they can be adjusted to the hearing capabilities of different species. Three behaviours are classified based in this approach, and the method achieves a good recognition of foraging behaviour (86–97% sensitivity, 89–98% precision and a reasonable recognition of flushing (79–86%, 66–80% and landing behaviour(73–91%, 79–92%. The Support Vector Machine has proven to be a robust classifier for this kind of classification, as generality and non-linearcapabilities are important. We conclude that vocalisations can be used to automatically detect behaviour of conflict wildlife species, and as such, may be used as an integrated part of awildlife management system.

  1. Plastics in soil: Analytical methods and possible sources.

    Science.gov (United States)

    Bläsing, Melanie; Amelung, Wulf

    2018-01-15

    At least 300 Mio t of plastic are produced annually, from which large parts end up in the environment, where it persists over decades, harms biota and enters the food chain. Yet, almost nothing is known about plastic pollution of soil; hence, the aims of this work are to review current knowledge on i) available methods for the quantification and identification of plastic in soil, ii) the quantity and possible input pathways of plastic into soil, (including first preliminary screening of plastic in compost), and iii) its fate in soil. Methods for plastic analyses in sediments can potentially be adjusted for application to soil; yet, the applicability of these methods for soil needs to be tested. Consequently, the current data base on soil pollution with plastic is still poor. Soils may receive plastic inputs via plastic mulching or the application of plastic containing soil amendments. In compost up to 2.38-1200mg plastic kg -1 have been found so far; the plastic concentration of sewage sludge varies between 1000 and 24,000 plastic items kg -1 . Also irrigation with untreated and treated wastewater (1000-627,000 and 0-125,000 plastic items m -3 , respectively) as well as flooding with lake water (0.82-4.42 plastic items m -3 ) or river water (0-13,751 items km -2 ) can provide major input pathways for plastic into soil. Additional sources comprise littering along roads and trails, illegal waste dumping, road runoff as well as atmospheric input. With these input pathways, plastic concentrations in soil might reach the per mill range of soil organic carbon. Most of plastic (especially >1μm) will presumably be retained in soil, where it persists for decades or longer. Accordingly, further research on the prevalence and fate of such synthetic polymers in soils is urgently warranted. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Analytical validation of a standardized scoring protocol for Ki67: phase 3 of an international multicenter collaboration

    Science.gov (United States)

    Leung, Samuel C Y; Nielsen, Torsten O; Zabaglo, Lila; Arun, Indu; Badve, Sunil S; Bane, Anita L; Bartlett, John M S; Borgquist, Signe; Chang, Martin C; Dodson, Andrew; Enos, Rebecca A; Fineberg, Susan; Focke, Cornelia M; Gao, Dongxia; Gown, Allen M; Grabau, Dorthe; Gutierrez, Carolina; Hugh, Judith C; Kos, Zuzana; Lænkholm, Anne-Vibeke; Lin, Ming-Gang; Mastropasqua, Mauro G; Moriya, Takuya; Nofech-Mozes, Sharon; Osborne, C Kent; Penault-Llorca, Frédérique M; Piper, Tammy; Sakatani, Takashi; Salgado, Roberto; Starczynski, Jane; Viale, Giuseppe; Hayes, Daniel F; McShane, Lisa M; Dowsett, Mitch

    2016-01-01

    Pathological analysis of the nuclear proliferation biomarker Ki67 has multiple potential roles in breast and other cancers. However, clinical utility of the immunohistochemical (IHC) assay for Ki67 immunohistochemistry has been hampered by unacceptable between-laboratory analytical variability. The International Ki67 Working Group has conducted a series of studies aiming to decrease this variability and improve the evaluation of Ki67. This study tries to assess whether acceptable performance can be achieved on prestained core-cut biopsies using a standardized scoring method. Sections from 30 primary ER+ breast cancer core biopsies were centrally stained for Ki67 and circulated among 22 laboratories in 11 countries. Each laboratory scored Ki67 using three methods: (1) global (4 fields of 100 cells each); (2) weighted global (same as global but weighted by estimated percentages of total area); and (3) hot-spot (single field of 500 cells). The intraclass correlation coefficient (ICC), a measure of interlaboratory agreement, for the unweighted global method (0.87; 95% credible interval (CI): 0.81–0.93) met the prespecified success criterion for scoring reproducibility, whereas that for the weighted global (0.87; 95% CI: 0.7999–0.93) and hot-spot methods (0.84; 95% CI: 0.77–0.92) marginally failed to do so. The unweighted global assessment of Ki67 IHC analysis on core biopsies met the prespecified criterion of success for scoring reproducibility. A few cases still showed large scoring discrepancies. Establishment of external quality assessment schemes is likely to improve the agreement between laboratories further. Additional evaluations are needed to assess staining variability and clinical validity in appropriate cohorts of samples. PMID:28721378

  3. Applications of Nuclear Analytical Methods for High Tech Industry

    International Nuclear Information System (INIS)

    Hossain, T.

    2013-01-01

    Silicon based semiconductor chip manufacturing is a worldwide high technology industry with numerous measurement issues. One of the major concerns in the semiconductor manufacturing is contamination such as the trace metal impurities. This concern is vividly illustrated by the fact that the manufacturing in this industry is done in ultra clean environment where the entire manufacturing facility or “Fab” is a clean room facility or each and every manufacturing tool is enclosed in a mini-environment Although semiconductor devices are fabricated on the surface of the Si wafers contamination in the bulk material is a major concern. Nuclear methods of analysis are uniquely suited for the contamination analysis in such a matrix. Many opportunities in the semiconductor manufacturing field exist for the nuclear methods to provide support services. Contamination analysis by NAA, depth profiles by NDP and prompt gamma analysis of H in thin films are a few examples. These needs are on-going and require commitment from the lab so that a manufacturing operation can rely on the delivery of these services when required

  4. An analytical method of estimating Value-at-Risk on the Belgrade Stock Exchange

    Directory of Open Access Journals (Sweden)

    Obadović Milica D.

    2009-01-01

    Full Text Available This paper presents market risk evaluation for a portfolio consisting of shares that are continuously traded on the Belgrade Stock Exchange, by applying the Value-at-Risk model - the analytical method. It describes the manner of analytical method application and compares the results obtained by implementing this method at different confidence levels. Method verification was carried out on the basis of the failure rate that demonstrated the confidence level for which this method was acceptable in view of the given conditions.

  5. Colloids in PWR primary and secondary coolant. Innovative analytical methods

    International Nuclear Information System (INIS)

    Nowotka, Karsten; Guillodo, Michael; Burchardt, Carsten; Geier, Roland; Lehr, Robert; Stellwag, Bernhard

    2014-01-01

    Transport and deposition of corrosion products in the colloid size range between 1 nm and 1 μm are important for heat transfer performance and corrosion in primary and secondary cooling circuits of LWRs. Direct analysis of the properties of small-sized colloids (< 0.45 μm) is difficult due to the pronounced change of the physicochemical properties of coolant samples in sampling lines. An innovative method, based on a filter cascade and developed in the AREVA Technical Center, named 'Colloid Catcher' (CC, patent pending), permits on-line measurements of the properties of corrosion products in the coolant of LWRs. CC measurements are complementary to classic trace analysis addressing the soluble content. Low and high temperature (up to 330°C) test sections are available, depending on our customer's needs. The CC contains differential pressure detectors at each of the three consecutive membrane filters which allow for an in-situ characterization without modification of the corrosion products chemical nature due to temperature changes and subsequent exposure to the atmosphere. With this method, a 'Colloid Fingerprint' of the test solution can be obtained, ideal for an assessment of the transport and deposition of corrosion products in laboratory and on-site studies. The on-line data can of course be complemented by post filtration membrane characterization by digestion and/or optical methods. The high temperature CC serves at the same time as a sampling point for grab samples, with good reproducibility thanks to continuous liquid flow. The CC has been designed to be deployable on laboratory or industrial cooling circuits. The CC test sections have been qualified using AREVA Technical Center's test loops. First test results obtained with the LT CC are presented. Laboratory data can be used to back up existing results and data of on-site measurement campaigns at BWR and PWR plants which were determined with a basic version of the LT CC

  6. Analytical Expressions of the Efficiency of Standard and High Contact Ratio Involute Spur Gears

    Directory of Open Access Journals (Sweden)

    Miguel Pleguezuelos

    2013-01-01

    Full Text Available Simple, traditional methods for computation of the efficiency of spur gears are based on the hypotheses of constant friction coefficient and uniform load sharing along the path of contact. However, none of them is accurate. The friction coefficient is variable along the path of contact, though average values can be often considered for preliminary calculations. Nevertheless, the nonuniform load sharing produced by the changing rigidity of the pair of teeth has significant influence on the friction losses, due to the different relative sliding at any contact point. In previous works, the authors obtained a nonuniform model of load distribution based on the minimum elastic potential criterion, which was applied to compute the efficiency of standard gears. In this work, this model of load sharing is applied to study the efficiency of both standard and high contact ratio involute spur gears (with contact ratio between 1 and 2 and greater than 2, resp.. Approximate expressions for the friction power losses and for the efficiency are presented assuming the friction coefficient to be constant along the path of contact. A study of the influence of some transmission parameters (as the gear ratio, pressure angle, etc. on the efficiency is also presented.

  7. Modelling of packet traffic with matrix analytic methods

    DEFF Research Database (Denmark)

    Andersen, Allan T.

    1995-01-01

    vot reveal any adverse behaviour. In fact the observed traffic seemed very close to what would be expected from Poisson traffic. The Changeover/Changeback procedure in SS7, which is used to redirect traffic in case of link failure, has been analyzed. The transient behaviour during a Changeover...... scenario was modelled using Markovian models. The Ordinary Differential Equations arising from these models were solved numerically. The results obtained seemed very similar to those obtained using a different method in previous work by Akinpelu & Skoog 1985. Recent measurement studies of packet traffic...... is found by noting the close relationship with the expressions for the corresponding infinite queue. For the special case of a batch Poisson arrival process this observation makes it possible to express the queue length at an arbitrary in terms of the corresponding queue lengths for the infinite case....

  8. Using an analytical geometry method to improve tiltmeter data presentation

    Science.gov (United States)

    Su, W.-J.

    2000-01-01

    The tiltmeter is a useful tool for geologic and geotechnical applications. To obtain full benefit from the tiltmeter, easy and accurate data presentations should be used. Unfortunately, the most commonly used method for tilt data reduction now may yield inaccurate and low-resolution results. This article describes a simple, accurate, and high-resolution approach developed at the Illinois State Geological Survey for data reduction and presentation. The orientation of tiltplates is determined first by using a trigonometric relationship, followed by a matrix transformation, to obtain the true amount of rotation change of the tiltplate at any given time. The mathematical derivations used for the determination and transformation are then coded into an integrated PC application by adapting the capabilities of commercial spreadsheet, database, and graphics software. Examples of data presentation from tiltmeter applications in studies of landfill covers, characterizations of mine subsidence, and investigations of slope stability are also discussed.

  9. Manual of analytical methods for the Environmental Health Laboratory

    International Nuclear Information System (INIS)

    Gray, C.E.

    1975-06-01

    The manual contains four sections: absorption spectrophotometry; general radiochemical procedures; instrumental analysis; and calibration of field instruments. Included in the individual analyses using absorption spectrophotometry is one for total iodine in oil. Radiochemical procedures are given for: actinides in urine and water; 137 Cs in soil and vegetation; 137 Cs in soil, urine, vegetation, and water; enriched uranium in urine; gross beta activity in soil, urine, vegetation, and water; plutonium in urine and soil; 210 Po in urine and water; 24 Na in air, blood, urine, and water; 90 Sr in soil, vegetation, and water; tritium in urine, water, and on swipes; and total uranium on fallout trays and in soil, urine, and water. Among the individual instrumental analyses is a spectrographic method for determining beryllium in air samples and swipes. (U.S.)

  10. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 4, Organic methods

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    This interim notice covers the following: extractable organic halides in solids, total organic halides, analysis by gas chromatography/Fourier transform-infrared spectroscopy, hexadecane extracts for volatile organic compounds, GC/MS analysis of VOCs, GC/MS analysis of methanol extracts of cryogenic vapor samples, screening of semivolatile organic extracts, GPC cleanup for semivolatiles, sample preparation for GC/MS for semi-VOCs, analysis for pesticides/PCBs by GC with electron capture detection, sample preparation for pesticides/PCBs in water and soil sediment, report preparation, Florisil column cleanup for pesticide/PCBs, silica gel and acid-base partition cleanup of samples for semi-VOCs, concentrate acid wash cleanup, carbon determination in solids using Coulometrics` CO{sub 2} coulometer, determination of total carbon/total organic carbon/total inorganic carbon in radioactive liquids/soils/sludges by hot persulfate method, analysis of solids for carbonates using Coulometrics` Model 5011 coulometer, and soxhlet extraction.

  11. AmO2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO2 Production

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Kevin John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bland, Galey Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fulwyler, James Brent [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garduno, Katherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Keller, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Klundt, Dylan James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lujan, Elmer J. W [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mark, Zoe Francoise Elise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mathew, Kattathu Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ortega, Laura Claire [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ottenfeld, Chelsea Faith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Porterfield, Donivan R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rearick, Michael Sean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rim, Jung Ho [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schake, Ann Rene [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schappert, Michael Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stanley, Floyd E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Thomas, Mariam R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wylie, Ernest Miller II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Xu, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-08

    Americium oxide samples will be measured for various analytes to support AmO2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO2 reference materials currently available for requested analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO2 production operations.

  12. Analytical Quality by Design Approach to Test Method Development and Validation in Drug Substance Manufacturing

    Directory of Open Access Journals (Sweden)

    N. V. V. S. S. Raman

    2015-01-01

    Full Text Available Pharmaceutical industry has been emerging rapidly for the last decade by focusing on product Quality, Safety, and Efficacy. Pharmaceutical firms increased the number of product development by using scientific tools such as QbD (Quality by Design and PAT (Process Analytical Technology. ICH guidelines Q8 to Q11 have discussed QbD implementation in API synthetic process and formulation development. ICH Q11 guidelines clearly discussed QbD approach for API synthesis with examples. Generic companies are implementing QbD approach in formulation development and even it is mandatory for USFDA perspective. As of now there is no specific requirements for AQbD (Analytical Quality by Design and PAT in analytical development from all regulatory agencies. In this review, authors have discussed the implementation of QbD and AQbD simultaneously for API synthetic process and analytical methods development. AQbD key tools are identification of ATP (Analytical Target Profile, CQA (Critical Quality Attributes with risk assessment, Method Optimization and Development with DoE, MODR (method operable design region, Control Strategy, AQbD Method Validation, and Continuous Method Monitoring (CMM. Simultaneous implementation of QbD activities in synthetic and analytical development will provide the highest quality product by minimizing the risks and even it is very good input for PAT approach.

  13. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-05-27

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

  14. Propulsion and launching analysis of variable-mass rockets by analytical methods

    Directory of Open Access Journals (Sweden)

    D.D. Ganji

    2013-09-01

    Full Text Available In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM, homotopy perturbation method (HPM and least square method (LSM were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a parametric study is performed here which includes the effect of exhaust velocity (Ce, burn rate (BR of fuel and diameter of cylindrical rocket (d on the motion of a sample rocket, and contours for showing the sensitivity of these parameters are plotted. The main results indicate that the rocket velocity and altitude are increased with increasing the Ce and BR and decreased with increasing the rocket diameter and drag coefficient.

  15. A SIMPLE ANALYTICAL METHOD TO DETERMINE SOLAR ENERGETIC PARTICLES' MEAN FREE PATH

    International Nuclear Information System (INIS)

    He, H.-Q.; Qin, G.

    2011-01-01

    To obtain the mean free path of solar energetic particles (SEPs) for a solar event, one usually has to fit time profiles of both flux and anisotropy from spacecraft observations to numerical simulations of SEPs' transport processes. This method can be called a simulation method. But a reasonably good fitting needs a lot of simulations, which demand a large amount of calculation resources. Sometimes, it is necessary to find an easy way to obtain the mean free path of SEPs quickly, for example, in space weather practice. Recently, Shalchi et al. provided an approximate analytical formula of SEPs' anisotropy time profile as a function of particles' mean free path for impulsive events. In this paper, we determine SEPs' mean free path by fitting the anisotropy time profiles from Shalchi et al.'s analytical formula to spacecraft observations. This new method can be called an analytical method. In addition, we obtain SEPs' mean free path with the traditional simulation methods. Finally, we compare the mean free path obtained with the simulation method to that of the analytical method to show that the analytical method, with some minor modifications, can give us a good, quick approximation of SEPs' mean free path for impulsive events.

  16. Analytical methods for 2,4-D (Dichlorophenoxyacetic acid) determination

    International Nuclear Information System (INIS)

    Martinez G, M.S.M.

    1999-01-01

    The 2,4-D herbicide is one of the main pesticides for controlling the bad grass in crops such as the water undergrowth. In Mexico the allowed bound of this pesticide is 0.05 mg/l in water of 2,4-D so it is required to have methods trusts and exacts, which can used in order to detected low concentration of it. In this work we show some for the conventional techniques and for establishing the 2,4-D concentrations. The UV-Vis spectrometer and liquids chromatography due that they are the most common used nowadays. Beside, we introduce a now developed technique, which is based on the neutronic activation analysis. Though use of the UV-Vis spectrometer technique it was possible target the concentrations interval between 1 and 200 mg/l. In the liquids chromatography interval was between 0.1 and 0.9, and by the neutronic activation analysis the interval was between 0.01 and 200 mg/l. (Author)

  17. An introduction to clinical microeconomic analysis: purposes and analytic methods.

    Science.gov (United States)

    Weintraub, W S; Mauldin, P D; Becker, E R

    1994-06-01

    The recent concern with health care economics has fostered the development of a new discipline that is generally called clinical microeconomics. This is a discipline in which microeconomic methods are used to study the economics of specific medical therapies. It is possible to perform stand alone cost analyses, but more profound insight into the medical decision making process may be accomplished by combining cost studies with measures of outcome. This is most often accomplished with cost-effectiveness or cost-utility studies. In cost-effectiveness studies there is one measure of outcome, often death. In cost-utility studies there are multiple measures of outcome, which must be grouped together to give an overall picture of outcome or utility. There are theoretical limitations to the determination of utility that must be accepted to perform this type of analysis. A summary statement of outcome is quality adjusted life years (QALYs), which is utility time socially discounted survival. Discounting is used because people value a year of future life less than a year of present life. Costs are made up of in-hospital direct, professional, follow-up direct, and follow-up indirect costs. Direct costs are for medical services. Indirect costs reflect opportunity costs such as lost time at work. Cost estimates are often based on marginal costs, or the cost for one additional procedure of the same type. Finally an overall statistic may be generated as cost per unit increase in effectiveness, such as dollars per QALY.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Standard methods for sampling freshwater fishes: Opportunities for international collaboration

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.

  19. JRC Guidelines for 1 - Selecting and/or validating analytical methods for cosmetics 2 - Recommending standardization steps of analytical methods

    OpenAIRE

    VINCENT Ursula

    2015-01-01

    The analysis of cosmetics constitutes a challenge mainly due to the large variety of ingredients and formulations, and to the complexity of cosmetic products, in particular due to huge matrix variability. In 2009, the European Commission issued a Regulation (Regulation (EC) N° 1223/2009 of the European Parliament and of the Council) establishing the requisites for cosmetic products and the responsibilities of the stakeholders. While the manufacturers' are responsible to ensure the safety of t...

  20. Waste Tank Organic Safety Program: Analytical methods development. Progress report, FY 1994

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.A.; Grant, K.E.

    1994-09-01

    The objectives of this task are to develop and document extraction and analysis methods for organics in waste tanks, and to extend these methods to the analysis of actual core samples to support the Waste Tank organic Safety Program. This report documents progress at Pacific Northwest Laboratory (a) during FY 1994 on methods development, the analysis of waste from Tank 241-C-103 (Tank C-103) and T-111, and the transfer of documented, developed analytical methods to personnel in the Analytical Chemistry Laboratory (ACL) and 222-S laboratory. This report is intended as an annual report, not a completed work

  1. Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Stambaugh, Cassandra [Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Hunt, Dylan; Tonner, Brian; Zhang, Geoffrey; Feygelman, Vladimir, E-mail: vladimir.feygelman@moffitt.org [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2015-08-15

    Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2

  2. Projected Regression Methods for Inverting Fredholm Integrals: Formalism and Application to Analytical Continuation

    Science.gov (United States)

    Arsenault, Louis-Francois; Neuberg, Richard; Hannah, Lauren A.; Millis, Andrew J.

    We present a machine learning-based statistical regression approach to the inversion of Fredholm integrals of the first kind by studying an important example for the quantum materials community, the analytical continuation problem of quantum many-body physics. It involves reconstructing the frequency dependence of physical excitation spectra from data obtained at specific points in the complex frequency plane. The approach provides a natural regularization in cases where the inverse of the Fredholm kernel is ill-conditioned and yields robust error metrics. The stability of the forward problem permits the construction of a large database of input-output pairs. Machine learning methods applied to this database generate approximate solutions which are projected onto the subspace of functions satisfying relevant constraints. We show that for low input noise the method performs as well or better than Maximum Entropy (MaxEnt) under standard error metrics, and is substantially more robust to noise. We expect the methodology to be similarly effective for any problem involving a formally ill-conditioned inversion, provided that the forward problem can be efficiently solved. AJM was supported by the Office of Science of the U.S. Department of Energy under Subcontract No. 3F-3138 and LFA by the Columbia Univeristy IDS-ROADS project, UR009033-05 which also provided part support to RN and LH.

  3. Application of capability indices and control charts in the analytical method control strategy.

    Science.gov (United States)

    Oliva, Alexis; Llabres Martinez, Matías

    2017-08-01

    In this study, we assessed the usefulness of control charts in combination with the process capability indices, C pm and C pk , in the control strategy of an analytical method. The traditional X-chart and moving range chart were used to monitor the analytical method over a 2-year period. The results confirmed that the analytical method is in-control and stable. Different criteria were used to establish the specifications limits (i.e. analyst requirements) for fixed method performance (i.e. method requirements). If the specification limits and control limits are equal in breadth, the method can be considered "capable" (C pm  = 1), but it does not satisfy the minimum method capability requirements proposed by Pearn and Shu (2003). Similar results were obtained using the C pk index. The method capability was also assessed as a function of method performance for fixed analyst requirements. The results indicate that the method does not meet the requirements of the analytical target approach. A real-example data of a SEC with light-scattering detection method was used as a model whereas previously published data were used to illustrate the applicability of the proposed approach. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Ernst Equation and Riemann Surfaces: Analytical and Numerical Methods

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Frederick J [FJE Enterprises, 511 County Route 59, Potsdam, NY 13676 (United States)

    2007-06-18

    source can be represented by discontinuities in the metric tensor components. The first two chapters of this book are devoted to some basic ideas: in the introductory chapter 1 the authors discuss the concept of integrability, comparing the integrability of the vacuum Ernst equation with the integrability of nonlinear equations of Korteweg-de Vries (KdV) type, while in chapter 2 they describe various circumstances in which the vacuum Ernst equation has been determined to be relevant, not only in connection with gravitation but also, for example, in the construction of solutions of the self-dual Yang-Mills equations. It is also in this chapter that one of several equivalent linear systems for the Ernst equation is described. The next two chapters are devoted to Dmitry Korotkin's concept of algebro-geometric solutions of a linear system: in chapter 3 the structure of such solutions of the vacuum Ernst equation, which involve Riemann theta functions of hyperelliptic algebraic curves of any genus, is contrasted with the periodic structure of such solutions of the KdV equation. How such solutions can be obtained, for example, by solving a matrix Riemann-Hilbert problem and how the metric tensor of the associated spacetime can be evaluated is described in detail. In chapter 4 the asymptotic behaviour and the similarity structure of the general algebro-geometric solutions of the Ernst equation are described, and the relationship of such solutions to the perhaps more familiar multi-soliton solutions is discussed. The next three chapters are based upon the authors' own published research: in chapter 5 it is shown that a problem involving counter-rotating infinitely thin disks of matter can be solved in terms of genus two Riemann theta functions, while in chapter 6 the authors describe numerical methods that facilitate the construction of such solutions, and in chapter 7 three-dimensional graphs are displayed that depict all metrical fields of the associated spacetime

  5. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  6. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  7. Evaluation and selection of in-situ leaching mining method using analytic hierarchy process

    International Nuclear Information System (INIS)

    Zhao Heyong; Tan Kaixuan; Liu Huizhen

    2007-01-01

    According to the complicated conditions and main influence factors of in-situ leaching min- ing, a model and processes of analytic hierarchy are established for evaluation and selection of in-situ leaching mining methods based on analytic hierarchy process. Taking a uranium mine in Xinjiang of China for example, the application of this model is presented. The results of analyses and calculation indicate that the acid leaching is the optimum project. (authors)

  8. A REVIEW: AN APPROACH TOWARDS THE ANALYTICAL METHOD DEVELOPMENT FOR DETERMINATION OF NEWER DRUGS

    OpenAIRE

    Kirtimaya Mishra*, Dr. K. Balamurugan1, Dr. R. Suresh1

    2017-01-01

    In this present scenario for treating various diseases several new drugs were invented. Before launching to the market these drugs must undergo analytical validation process. In this review some of analytical techniques such as ultraviolet/ visible spectrophotometry, fluorimetry, capillary electrophoresis, and chromatographic methods (gas chromatography and high-performance liquid chromatography), LC-MS, GC-MS, SOLID PHASE EXTRACTION, NMR, MASS Spectrophotometry LC/MS/MS LC/UV X-ray crystallo...

  9. Normalization method for metabolomics data using optimal selection of multiple internal standards

    Directory of Open Access Journals (Sweden)

    Yetukuri Laxman

    2007-03-01

    Full Text Available Abstract Background Success of metabolomics as the phenotyping platform largely depends on its ability to detect various sources of biological variability. Removal of platform-specific sources of variability such as systematic error is therefore one of the foremost priorities in data preprocessing. However, chemical diversity of molecular species included in typical metabolic profiling experiments leads to different responses to variations in experimental conditions, making normalization a very demanding task. Results With the aim to remove unwanted systematic variation, we present an approach that utilizes variability information from multiple internal standard compounds to find optimal normalization factor for each individual molecular species detected by metabolomics approach (NOMIS. We demonstrate the method on mouse liver lipidomic profiles using Ultra Performance Liquid Chromatography coupled to high resolution mass spectrometry, and compare its performance to two commonly utilized normalization methods: normalization by l2 norm and by retention time region specific standard compound profiles. The NOMIS method proved superior in its ability to reduce the effect of systematic error across the full spectrum of metabolite peaks. We also demonstrate that the method can be used to select best combinations of standard compounds for normalization. Conclusion Depending on experiment design and biological matrix, the NOMIS method is applicable either as a one-step normalization method or as a two-step method where the normalization parameters, influenced by variabilities of internal standard compounds and their correlation to metabolites, are first calculated from a study conducted in repeatability conditions. The method can also be used in analytical development of metabolomics methods by helping to select best combinations of standard compounds for a particular biological matrix and analytical platform.

  10. Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r).

    Science.gov (United States)

    Nelms, Benjamin; Stambaugh, Cassandra; Hunt, Dylan; Tonner, Brian; Zhang, Geoffrey; Feygelman, Vladimir

    2015-08-01

    The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. dicom RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms-pinnacle (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)-were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, Dmax, Dmin, and doses to % volume: D99, D95, D5, D1, D0.03 cm(3)) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. In Test 1, pinnacle produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, pinnacle and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding Dmin and Dmax as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for pinnacle vs PlanIQ in Test 1, while Test 2

  11. Selenium contaminated waters: An overview of analytical methods, treatment options and recent advances in sorption methods.

    Science.gov (United States)

    Santos, Sílvia; Ungureanu, Gabriela; Boaventura, Rui; Botelho, Cidália

    2015-07-15

    Selenium is an essential trace element for many organisms, including humans, but it is bioaccumulative and toxic at higher than homeostatic levels. Both selenium deficiency and toxicity are problems around the world. Mines, coal-fired power plants, oil refineries and agriculture are important examples of anthropogenic sources, generating contaminated waters and wastewaters. For reasons of human health and ecotoxicity, selenium concentration has to be controlled in drinking-water and in wastewater, as it is a potential pollutant of water bodies. This review article provides firstly a general overview about selenium distribution, sources, chemistry, toxicity and environmental impact. Analytical techniques used for Se determination and speciation and water and wastewater treatment options are reviewed. In particular, published works on adsorption as a treatment method for Se removal from aqueous solutions are critically analyzed. Recent published literature has given particular attention to the development and search for effective adsorbents, including low-cost alternative materials. Published works mostly consist in exploratory findings and laboratory-scale experiments. Binary metal oxides and LDHs (layered double hydroxides) have presented excellent adsorption capacities for selenium species. Unconventional sorbents (algae, agricultural wastes and other biomaterials), in raw or modified forms, have also led to very interesting results with the advantage of their availability and low-cost. Some directions to be considered in future works are also suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. MULTIPLE CRITERA METHODS WITH FOCUS ON ANALYTIC HIERARCHY PROCESS AND GROUP DECISION MAKING

    Directory of Open Access Journals (Sweden)

    Lidija Zadnik-Stirn

    2010-12-01

    Full Text Available Managing natural resources is a group multiple criteria decision making problem. In this paper the analytic hierarchy process is the chosen method for handling the natural resource problems. The one decision maker problem is discussed and, three methods: the eigenvector method, data envelopment analysis method, and logarithmic least squares method are presented for the derivation of the priority vector. Further, the group analytic hierarchy process is discussed and six methods for the aggregation of individual judgments or priorities: weighted arithmetic mean method, weighted geometric mean method, and four methods based on data envelopment analysis are compared. The case study on land use in Slovenia is applied. The conclusions review consistency, sensitivity analyses, and some future directions of research.

  13. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.

    2008-12-17

    This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

  14. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    International Nuclear Information System (INIS)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S.

    2013-01-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  15. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    Energy Technology Data Exchange (ETDEWEB)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: ppessoa@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@imp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  16. Assessment of Two Analytical Methods in Solving the Linear and Nonlinear Elastic Beam Deformation Problems

    DEFF Research Database (Denmark)

    Barari, Amin; Ganjavi, B.; Jeloudar, M. Ghanbari

    2010-01-01

    Purpose – In the last two decades with the rapid development of nonlinear science, there has appeared ever-increasing interest of scientists and engineers in the analytical techniques for nonlinear problems. This paper considers linear and nonlinear systems that are not only regarded as general...... boundary value problems, but also are used as mathematical models in viscoelastic and inelastic flows. The purpose of this paper is to present the application of the homotopy-perturbation method (HPM) and variational iteration method (VIM) to solve some boundary value problems in structural engineering...... and fluid mechanics. Design/methodology/approach – Two new but powerful analytical methods, namely, He's VIM and HPM, are introduced to solve some boundary value problems in structural engineering and fluid mechanics. Findings – Analytical solutions often fit under classical perturbation methods. However...

  17. Origin Determination and Differentiation of Gelatin Species of Bovine, Porcine, and Piscine through Analytical Methods

    Directory of Open Access Journals (Sweden)

    Hatice Saadiye Eryılmaz

    2017-06-01

    Full Text Available Gelatin origin determination has been a crucial issue with respect to religion and health concerns. It is necessary to analyze the origin of gelatin with reliable methods to ensure not only consumer choices but also safety and legal requirements such as labeling. There are many analytical methods developed for detection and/or quantification of gelatin from different sources including bovine, porcine and piscine. These analytical methods can be divided into physicochemical, chromatographic, immunochemical, spectroscopic and molecular methods. Moreover, computational methods have been used in some cases consecutively to ensure sensitivity of the analytical methods. Every method has different advantages and limitations due to their own principles, applied food matrix and process conditions of material. The present review intends to give insight into novel analytical methods and perspectives that have been developed to differentiate porcine, bovine and piscine gelatins and to establish their authenticity. Almost every method can be succeeded in origin determination; however, it is a matter of sensitivity in that some researches fail to ensure sufficient differentiation.

  18. Analytical method comparisons for the accurate determination of PCBs in sediments

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M.; Yarita, T.; Aoyagi, Y.; Yamazaki, M.; Takatsu, A. [National Metrology Institute of Japan, Tsukuba (Japan)

    2004-09-15

    National Metrology Institute of Japan in National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has been developing several matrix reference materials, for example, sediments, water and biological tissues, for the determinations of heavy metals and organometallic compounds. The matrix compositions of those certified reference materials (CRMs) are similar to compositions of actual samples, and those are useful for validating analytical procedures. ''Primary methods of measurements'' are essential to obtain accurate and SI-traceable certified values in the reference materials, because the methods have the highest quality of measurement. However, inappropriate analytical operations, such as incomplete extraction of analytes or crosscontamination during analytical procedures, will cause error of analytical results, even if one of the primary methods, isotope-dilution, is utilized. To avoid possible procedural bias for the certification of reference materials, we employ more than two analytical methods which have been optimized beforehand. Because the accurate determination of trace POPs in the environment is important to evaluate their risk, reliable CRMs are required by environmental chemists. Therefore, we have also been preparing matrix CRMs for the determination of POPs. To establish accurate analytical procedures for the certification of POPs, extraction is one of the critical steps as described above. In general, conventional extraction techniques for the determination of POPs, such as Soxhlet extraction (SOX) and saponification (SAP), have been characterized well, and introduced as official methods for environmental analysis. On the other hand, emerging techniques, such as microwave-assisted extraction (MAE), pressurized fluid extraction (PFE) and supercritical fluid extraction (SFE), give higher recovery yields of analytes with relatively short extraction time and small amount of solvent, by reasons of the high

  19. Investigation of Unbalanced Magnetic Force in Magnetic Geared Machine Using Analytical Methods

    DEFF Research Database (Denmark)

    Zhang, Xiaoxu; Liu, Xiao; Chen, Zhe

    2016-01-01

    The electromagnetic structure of the magnetic geared machine (MGM) may induce a significant unbalanced magnetic force (UMF). However, few methods have been developed to theoretically reveal the essential reasons for this issue in the MGM. In this paper, an analytical method based on an air...

  20. Flammable gas safety program. Analytical methods development: FY 1994 progress report

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Wahl, K.; Steele, R.

    1994-09-01

    This report describes the status of developing analytical methods to account for the organic components in Hanford waste tanks, with particular focus on tanks assigned to the Flammable Gas Watch List. The methods that have been developed are illustrated by their application to samples obtained from Tank 241-SY-101 (Tank 101-SY)

  1. On Approximate Analytical Solutions of Nonlinear Vibrations of Inextensible Beams using Parameter-Expansion Method

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Lund, Erik; Thomsen, Ole Thybo

    2010-01-01

    In this work, an analytical method, which is referred to as Parameter-expansion Method is used to obtain the exact solution for the problem of nonlinear vibrations of an inextensible beam. It is shown that one term in the series expansion is sufficient to obtain a highly accurate solution, which...

  2. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  3. EVALUATION OF ANALYTICAL METHODS FOR DETERMINING PESTICIDES IN BABY FOOD AND ADULT DUPLICATE-DIET SAMPLES

    Science.gov (United States)

    Determinations of pesticides in food are often complicated by the presence of fats and require multiple cleanup steps before analysis. Cost-effective analytical methods are needed for conducting large-scale exposure studies. We examined two extraction methods, supercritical flu...

  4. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. The estimated parameters are the location, lateral extent or width and depth to top surface of the prism. Forward modelling is attempted by 2D-Finite. Difference method. The proposed ...

  5. Approximate Analytic and Numerical Solutions to Lane-Emden Equation via Fuzzy Modeling Method

    Directory of Open Access Journals (Sweden)

    De-Gang Wang

    2012-01-01

    Full Text Available A novel algorithm, called variable weight fuzzy marginal linearization (VWFML method, is proposed. This method can supply approximate analytic and numerical solutions to Lane-Emden equations. And it is easy to be implemented and extended for solving other nonlinear differential equations. Numerical examples are included to demonstrate the validity and applicability of the developed technique.

  6. An Analytical Investigation of Three General Methods of Calculating Chemical-Equilibrium Compositions

    Science.gov (United States)

    Zeleznik, Frank J.; Gordon, Sanford

    1960-01-01

    The Brinkley, Huff, and White methods for chemical-equilibrium calculations were modified and extended in order to permit an analytical comparison. The extended forms of these methods permit condensed species as reaction products, include temperature as a variable in the iteration, and permit arbitrary estimates for the variables. It is analytically shown that the three extended methods can be placed in a form that is independent of components. In this form the Brinkley iteration is identical computationally to the White method, while the modified Huff method differs only'slightly from these two. The convergence rates of the modified Brinkley and White methods are identical; and, further, all three methods are guaranteed to converge and will ultimately converge quadratically. It is concluded that no one of the three methods offers any significant computational advantages over the other two.

  7. Standard Test Method for Environmental Resistance of Aerospace Transparencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers determination of the effects of exposure to thermal shock, condensing humidity, and simulated weather on aerospace transparent enclosures. 1.2 This test method is not recommended for quality control nor is it intended to provide a correlation to actual service life. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3.1 Exceptions—Certain inch-pound units are furnished in parentheses (not mandatory) and certain temperatures in Fahrenheit associated with other standards are also furnished. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard guide for establishing a quality assurance program for analytical chemistry laboratories within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This guide covers the establishment of a quality assurance (QA) program for analytical chemistry laboratories within the nuclear industry. Reference to key elements of ANSI/ISO/ASQC Q9001, Quality Systems, provides guidance to the functional aspects of analytical laboratory operation. When implemented as recommended, the practices presented in this guide will provide a comprehensive QA program for the laboratory. The practices are grouped by functions, which constitute the basic elements of a laboratory QA program. 1.2 The essential, basic elements of a laboratory QA program appear in the following order: Section Organization 5 Quality Assurance Program 6 Training and Qualification 7 Procedures 8 Laboratory Records 9 Control of Records 10 Control of Procurement 11 Control of Measuring Equipment and Materials 12 Control of Measurements 13 Deficiencies and Corrective Actions 14

  9. System and Method for Providing a Climate Data Analytic Services Application Programming Interface Distribution Package

    Science.gov (United States)

    Schnase, John L. (Inventor); Duffy, Daniel Q. (Inventor); Tamkin, Glenn S. (Inventor)

    2016-01-01

    A system, method and computer-readable storage devices for providing a climate data analytic services application programming interface distribution package. The example system can provide various components. The system provides a climate data analytic services application programming interface library that enables software applications running on a client device to invoke the capabilities of a climate data analytic service. The system provides a command-line interface that provides a means of interacting with a climate data analytic service by issuing commands directly to the system's server interface. The system provides sample programs that call on the capabilities of the application programming interface library and can be used as templates for the construction of new client applications. The system can also provide test utilities, build utilities, service integration utilities, and documentation.

  10. Analytical method for turbine blade temperature mapping to estimate a pyrometer input signal

    OpenAIRE

    MacKay, James D.

    1987-01-01

    The purpose of this thesis is to develop a method to estimate local blade temperatures in a gas turbine for comparison with the output signal of an experimental pyrometer. The goal of the method is to provide a temperature measurement benchmark based on a knowledge of blade geometry and engine operating conditions. A survey of currently available methods is discussed including both experimental and analytical techniques.The purpose of this thesis is to develop a method to estim...

  11. Analytical method of CIM to PIM transformation in Model Driven Architecture (MDA

    Directory of Open Access Journals (Sweden)

    Martin Kardos

    2010-06-01

    Full Text Available Information system’s models on higher level of abstraction have become a daily routine in many software companies. The concept of Model Driven Architecture (MDA published by standardization body OMG1 since 2001 has become a concept for creation of software applications and information systems. MDA specifies four levels of abstraction: top three levels are created as graphical models and the last one as implementation code model. Many research works of MDA are focusing on the lower levels and transformations between each other. The top level of abstraction, called Computation Independent Model (CIM and its transformation to the lower level called Platform Independent Model (PIM is not so extensive research topic. Considering to a great importance and usability of this level in practice of IS2Keywords: transformation, MDA, CIM, PIM, UML, DFD. development now our research activity is focused to this highest level of abstraction – CIM and its possible transformation to the lower PIM level. In this article we are presenting a possible solution of CIM modeling and its analytic method of transformation to PIM.

  12. Quantification of camalexin, a phytoalexin from Arabidopsis thaliana: a comparison of five analytical methods.

    Science.gov (United States)

    Beets, Caryn; Dubery, Ian

    2011-12-15

    Camalexin is a phytoalexin of Arabidopsis thaliana and an important component of inducible defenses. Accurate quantification of low concentrations suffers from interference by structurally related metabolites. A. thaliana plants were induced with silver nitrate and camalexin was extracted using methanol and identified and quantified by (i) TLC as a blue fluorescent band, (ii) microtiter plate-based fluorescence spectroscopy, (iii) GC on a midpolar column coupled to flame ionization detection, (iv) C(18) HPLC coupled to a photodiode detector, and (v) UPLC coupled to a mass spectrometer detector. Standard curves over the range of 0.1-15 μg ml(-1) gave R(2) values from 0.996 to 0.999. The different methods were compared and evaluated for their ability to detect and quantify increasing concentrations (camalexin. Each of the techniques presented advantages and disadvantages with regard to accuracy, precision, interference, analytical sensitivity, and limits of detection. TLC is a good qualitative technique for the identification of camalexin and fluorescence spectroscopy is subject to quenching when performed on crude extracts. Comparable results were obtained with GC-FID, HPLC-PDA, and UPLC-MS, with UPLC-MS having the added advantage of short analysis times and detection based on accurate mass. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Development and validation of analytical method for Naftopidil in human plasma by LC–MS/MS

    Directory of Open Access Journals (Sweden)

    Pritam S. Jain

    2015-09-01

    Full Text Available A highly sensitive and simple high-performance liquid chromatographic–tandem mass spectrometric (LC–MS-MS assay is developed and validated for the quantification of Naftopidil in human plasma. Naftopidil is extracted from human plasma by methyl tertiary butyl ether and analyzed using a reversed-phase gradient elution on a discovery C 18 5 μ (50 × 4.6 column. A methanol: 2 mM ammonium formate (90:10 as mobile phase, is used and detection was performed by MS using electrospray ionization in positive mode. Propranolol is used as the internal standard. The lower limits of quantification are 0.495 ng/mL. The calibration curves are linear over the concentration range of 0.495–200.577 ng/mL of plasma for each analyte. This novel LC–MS-MS method shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic studies in humans.

  14. 237 Np analytical method using 239 Np tracers and application to a contaminated nuclear disposal facility

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Mathew S.; Morrison, Samuel S.; Clark, Sue B.; Olson, John E.; Watrous, Matthew G.

    2017-06-01

    Environmental 237Np analyses are challenged by low 237Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237Np analytical approach employing the short lived 239Np (t1/2 = 2.3 days) as a chemical yield tracer followed by 237Np quantification using inductively coupled plasma-mass spectrometry. 239Np tracer is obtained via separation from a 243Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 watt “Walmart” microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on the order of 106 and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237Np contamination within 600 meters of this site, with maximum 237Np concentrations on the order of 103 times greater than nuclear weapons testing fallout levels.

  15. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. A Table Lookup Method for Exact Analytical Solutions of Nonlinear Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Ji Juan-Juan

    2017-01-01

    Full Text Available A table lookup method for solving nonlinear fractional partial differential equations (fPDEs is proposed in this paper. Looking up the corresponding tables, we can quickly obtain the exact analytical solutions of fPDEs by using this method. To illustrate the validity of the method, we apply it to construct the exact analytical solutions of four nonlinear fPDEs, namely, the time fractional simplified MCH equation, the space-time fractional combined KdV-mKdV equation, the (2+1-dimensional time fractional Zoomeron equation, and the space-time fractional ZKBBM equation. As a result, many new types of exact analytical solutions are obtained including triangular periodic solution, hyperbolic function solution, singular solution, multiple solitary wave solution, and Jacobi elliptic function solution.

  17. Simplified Analytical Methods to Analyze Lock Gates Submitted to Ship Collisions and Earthquakes

    Directory of Open Access Journals (Sweden)

    Buldgen Loic

    2015-09-01

    Full Text Available This paper presents two simplified analytical methods to analyze lock gates submitted to two different accidental loads. The case of an impact involving a vessel is first investigated. In this situation, the resistance of the struck gate is evaluated by assuming a local and a global deforming mode. The super-element method is used in the first case, while an equivalent beam model is simultaneously introduced to capture the overall bending motion of the structure. The second accidental load considered in this paper is the seismic action, for which an analytical method is presented to evaluate the total hydrodynamic pressure applied on a lock gate during an earthquake, due account being taken of the fluid-structure interaction. For each of these two actions, numerical validations are presented and the analytical results are compared to finite-element solutions.

  18. Development of CAD implementing the algorithm of boundary elements’ numerical analytical method

    Directory of Open Access Journals (Sweden)

    Yulia V. Korniyenko

    2015-03-01

    Full Text Available Up to recent days the algorithms for numerical-analytical boundary elements method had been implemented with programs written in MATLAB environment language. Each program had a local character, i.e. used to solve a particular problem: calculation of beam, frame, arch, etc. Constructing matrices in these programs was carried out “manually” therefore being time-consuming. The research was purposed onto a reasoned choice of programming language for new CAD development, allows to implement algorithm of numerical analytical boundary elements method and to create visualization tools for initial objects and calculation results. Research conducted shows that among wide variety of programming languages the most efficient one for CAD development, employing the numerical analytical boundary elements method algorithm, is the Java language. This language provides tools not only for development of calculating CAD part, but also to build the graphic interface for geometrical models construction and calculated results interpretation.

  19. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Analysis of plasticizers in PVC medical devices: Performance comparison of eight analytical methods.

    Science.gov (United States)

    Bernard, L; Bourdeaux, D; Pereira, B; Azaroual, N; Barthélémy, C; Breysse, C; Chennell, P; Cueff, R; Dine, T; Eljezi, T; Feutry, F; Genay, S; Kambia, N; Lecoeur, M; Masse, M; Odou, P; Radaniel, T; Simon, N; Vaccher, C; Verlhac, C; Yessad, M; Décaudin, B; Sautou, V

    2017-01-01

    A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED 1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC-MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the " blind test " carried out on 10 MD samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Validation of analytical method to calculate the concentration of conjugated monoclonal antibody

    International Nuclear Information System (INIS)

    Alcarde, Lais F.; Massicano, Adriana V.F.; Oliveira, Ricardo S.; Araujo, Elaine B. de

    2013-01-01

    The objective of this study was to develop a quantitative analytical method using high performance liquid chromatography (HPLC) to determine the antibody concentration in conjunction with bifunctional chelator. Assays were performed using a high performance liquid chromatograph, and the following conditions were used: flow rate of 1 mL / min, 15 min run time, 0.2 M sodium phosphate buffer pH 7.0 as the mobile phase and column of molecular exclusion BioSep SEC S-3000 (300 x 7.8 mm, 5 μM - Phenomenex). The calibration curve was obtained with AcM diluted in 0.2 M sodium phosphate buffer pH 7.0 by serial dilution, yielding the concentrations: 400 μg/mL, 200 μg/mL, 100 μg/mL, 50 μg/mL, 25 μg/mL and 12.5 μg/mL. From the calibration curve calculated the equation of the line and with it the concentration of the immunoconjugate. To ensure the validity of the method accuracy and precision studies were conducted. The accuracy test consisted in the evaluation of 3 samples of known concentration, being this test performed with low concentrations (50 μg/mL), medium (100 μg/mL) and high (200 μg/mL). The precision test consisted of 3 consecutive measurements of one sample of known concentration, subject to the conditions set forth above for the other tests. The correlation coefficient of the standard curve was greater than 97%, the accuracy was satisfactory at low concentrations as well as accuracy. The method was validated by showing it for the accurate and precise determination of the concentration of the immunoconjugate. Furthermore, this assay was found to be extremely important, because using the correct mass of the protein, the radiochemical purity of the radioimmunoconjugate was above 95% in all studies

  2. Possibilities of Utilizing the Method of Analytical Hierarchy Process Within the Strategy of Corporate Social Business

    Science.gov (United States)

    Drieniková, Katarína; Hrdinová, Gabriela; Naňo, Tomáš; Sakál, Peter

    2010-01-01

    The paper deals with the analysis of the theory of corporate social responsibility, risk management and the exact method of analytic hierarchic process that is used in the decision-making processes. The Chapters 2 and 3 focus on presentation of the experience with the application of the method in formulating the stakeholders' strategic goals within the Corporate Social Responsibility (CSR) and simultaneously its utilization in minimizing the environmental risks. The major benefit of this paper is the application of Analytical Hierarchy Process (AHP).

  3. Progress in analytical methods for the detection of geographical origin and authenticity of tea (Camellia sinensis)

    International Nuclear Information System (INIS)

    Yuan Yuwei; Hu Guixian; Shao Shengzhi; Zhang Yongzhi; Zhang Yu; Zhu Jiahong; Yang Guiling; Zhang Zhiheng

    2013-01-01

    Tea (Camellia sinensis) is one of the important agricultural products with obvious regional characteristics. Analytical methods are very important for the protection of geographical origin and authenticity of tea. The developments of analytical methods including stable isotope determination, multi-elements determination, near infrared reflectance spectroscopy, chemical fingerprint and others were reviewed. Major problems on tea origin and authenticity detection were discussed in this study, and some suggestions were also proposed which would be useful for the protection of geographical origin of tea in China. (authors)

  4. Study of Injection Molding Warpage Using Analytic Hierarchy Process and Taguchi Method

    Directory of Open Access Journals (Sweden)

    Dyi-Cheng Chen

    2016-10-01

    Full Text Available This study integrated Analytic Hierarchy Process and Taguchi method to investigate into injection molding warpage. The warpage important factor will be elected by Analytic Hierarchy Process (AHP, the AHP hierarchy analysis factor from documents collected and aggregate out data, then through the expert questionnaire delete low weight factor. Finally, we used Taguchi quality engineering method to decide injection molding optimized combination factors. Furthermore, the paper used injection pressure, holding pressure, holding time, mold temperature to analyze four factors, three levels Taguchi design data. Moreover, the paper discussed the reaction of each factor on the S / N ratio and analysis of variance to obtain the best combination of minimal warpage.

  5. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  6. Internal Standard Method for the Determination of Au and some ...

    African Journals Online (AJOL)

    Abstract. A method is described for the determination of Au, Pt, Pd, Ru and Rh in a converter matte sample, using inductively coupled plasma optical emission spectrometry (ICP-OES), with Y or Sc as internal standard. The results obtained by this method are discussed and compared with values obtained by an independent ...

  7. An analytical-numerical comprehensive method for optimizing the fringing magnetic field

    International Nuclear Information System (INIS)

    Xiao Meiqin; Mao Naifeng

    1991-01-01

    The criterion of optimizing the fringing magnetic field is discussed, and an analytical-numerical comprehensive method for realizing the optimization is introduced. The method mentioned above consists of two parts, the analytical part calculates the field of the shims, which corrects the fringing magnetic field by using uniform magnetizing method; the numerical part fulfils the whole calculation of the field distribution by solving the equation of magnetic vector potential A within the region covered by arbitrary triangular meshes with the aid of finite difference method and successive over relaxation method. On the basis of the method, the optimization of the fringing magnetic field for a large-scale electromagnetic isotope separator is finished

  8. Research on the simultaneous multi-components analytical method for polluted soil

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kang Sup; Song, Duk Young; Choi, Byung In; Kim, Kun Han; Eum, Chul Hun; Jeon, Chi Wan; Lee, Jung Hwa [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Dissolution properties for the several inorganic pollutants in soils have been studied and simultaneous multi-components analytical method has been established with using ICP/MS for 13 monitoring elements in order to protect water and soil environments. And addition, more effective new analytical methods have been studied for TPH(total petroleum hydrocarbon) and organophosphorus compounds in soils. Several inorganic pollutants were spiked to 3 kinds of fresh soils which were sand, clay, loam. The dissolution properties of the prepared samples were investigated under the various extracting conditions such as extracting time, acid concentration, particle size, etc. in order to take basic information about the process of extraction test and improvement of related analytical methods. As the results, dissolution properties were affected mainly by acid concentration in extraction procedure and mineral composition of soils. On the other hand, extracting time, sort of acids and particle size of soils has a little influence on the dissolution properties. Cd revealed very high dissolving efficiency and As was very low in whole extracting test. Current analytical methods for the determination of soils are based on the purge and trap for volatiles such as gasoline and solvent extraction for semivolatiles such as kerosene and diesel oils. These methods are not proper in cost and time. In addition to, there are potential for analyte contamination and some problems in pretreatment procedure. In this study , we have discussed simultaneous determination of TPH containing gasoline, kerosene, diesel oils and etc. And determination of Organophosphorus compounds in soils has studied. In this procedure, the application of ultrasonication methods and several extraction methods were compared. In the results of this study, we could take very low practical detection limit and good precision. Approved methods were suitable for the determination of oils and pesticides in soil at high and low

  9. Analytical recovery of protozoan enumeration methods: have drinking water QMRA models corrected or created bias?

    Science.gov (United States)

    Schmidt, P J; Emelko, M B; Thompson, M E

    2013-05-01

    Quantitative microbial risk assessment (QMRA) is a tool to evaluate the potential implications of pathogens in a water supply or other media and is of increasing interest to regulators. In the case of potentially pathogenic protozoa (e.g. Cryptosporidium oocysts and Giardia cysts), it is well known that the methods used to enumerate (oo)cysts in samples of water and other media can have low and highly variable analytical recovery. In these applications, QMRA has evolved from ignoring analytical recovery to addressing it in point-estimates of risk, and then to addressing variation of analytical recovery in Monte Carlo risk assessments. Often, variation of analytical recovery is addressed in exposure assessment by dividing concentration values that were obtained without consideration of analytical recovery by random beta-distributed recovery values. A simple mathematical proof is provided to demonstrate that this conventional approach to address non-constant analytical recovery in drinking water QMRA will lead to overestimation of mean pathogen concentrations. The bias, which can exceed an order of magnitude, is greatest when low analytical recovery values are common. A simulated dataset is analyzed using a diverse set of approaches to obtain distributions representing temporal variation in the oocyst concentration, and mean annual risk is then computed from each concentration distribution using a simple risk model. This illustrative example demonstrates that the bias associated with mishandling non-constant analytical recovery and non-detect samples can cause drinking water systems to be erroneously classified as surpassing risk thresholds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Standard test method for conducting potentiodynamic polarization resistance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers an experimental procedure for polarization resistance measurements which can be used for the calibration of equipment and verification of experimental technique. The test method can provide reproducible corrosion potentials and potentiodynamic polarization resistance measurements. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Statistical methods for evaluating the attainment of cleanup standards

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, R.O.; Simpson, J.C.

    1992-12-01

    This document is the third volume in a series of volumes sponsored by the US Environmental Protection Agency (EPA), Statistical Policy Branch, that provide statistical methods for evaluating the attainment of cleanup Standards at Superfund sites. Volume 1 (USEPA 1989a) provides sampling designs and tests for evaluating attainment of risk-based standards for soils and solid media. Volume 2 (USEPA 1992) provides designs and tests for evaluating attainment of risk-based standards for groundwater. The purpose of this third volume is to provide statistical procedures for designing sampling programs and conducting statistical tests to determine whether pollution parameters in remediated soils and solid media at Superfund sites attain site-specific reference-based standards. This.document is written for individuals who may not have extensive training or experience with statistical methods. The intended audience includes EPA regional remedial project managers, Superfund-site potentially responsible parties, state environmental protection agencies, and contractors for these groups.

  12. Standardization of Laboratory Methods for the PERCH Study

    Science.gov (United States)

    Karron, Ruth A.; Morpeth, Susan C.; Bhat, Niranjan; Levine, Orin S.; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Knoll, Maria Deloria; Kotloff, Karen L.; Madhi, Shabir A.; Scott, J. Anthony G.; Thea, Donald M.; Adrian, Peter V.; Ahmed, Dilruba; Alam, Muntasir; Anderson, Trevor P.; Antonio, Martin; Baillie, Vicky L.; Dione, Michel; Endtz, Hubert P.; Gitahi, Caroline; Karani, Angela; Kwenda, Geoffrey; Maiga, Abdoul Aziz; McClellan, Jessica; Mitchell, Joanne L.; Morailane, Palesa; Mugo, Daisy; Mwaba, John; Mwansa, James; Mwarumba, Salim; Nyongesa, Sammy; Panchalingam, Sandra; Rahman, Mustafizur; Sawatwong, Pongpun; Tamboura, Boubou; Toure, Aliou; Whistler, Toni; O’Brien, Katherine L.; Murdoch, David R.

    2017-01-01

    Abstract The Pneumonia Etiology Research for Child Health study was conducted across 7 diverse research sites and relied on standardized clinical and laboratory methods for the accurate and meaningful interpretation of pneumonia etiology data. Blood, respiratory specimens, and urine were collected from children aged 1–59 months hospitalized with severe or very severe pneumonia and community controls of the same age without severe pneumonia and were tested with an extensive array of laboratory diagnostic tests. A standardized testing algorithm and standard operating procedures were applied across all study sites. Site laboratories received uniform training, equipment, and reagents for core testing methods. Standardization was further assured by routine teleconferences, in-person meetings, site monitoring visits, and internal and external quality assurance testing. Targeted confirmatory testing and testing by specialized assays were done at a central reference laboratory. PMID:28575358

  13. Standard test method for instrumented impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard establishes the requirements for performing instrumented Charpy V-Notch (CVN) and instrumented Miniaturized Charpy V-Notch (MCVN) impact tests on metallic materials. This method, which is based on experience developed testing steels, provides further information (in addition to the total absorbed energy) on the fracture behavior of the tested materials. Minimum requirements are given for measurement and recording equipment such that similar sensitivity and comparable total absorbed energy measurements to those obtained in Test Methods E 23 and E 2248 are achieved. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Comparative analysis of methods for real-time analytical control of chemotherapies preparations.

    Science.gov (United States)

    Bazin, Christophe; Cassard, Bruno; Caudron, Eric; Prognon, Patrice; Havard, Laurent

    2015-10-15

    Control of chemotherapies preparations are now an obligation in France, though analytical control is compulsory. Several methods are available and none of them is presumed as ideal. We wanted to compare them so as to determine which one could be the best choice. We compared non analytical (visual and video-assisted, gravimetric) and analytical (HPLC/FIA, UV/FT-IR, UV/Raman, Raman) methods thanks to our experience and a SWOT analysis. The results of the analysis show great differences between the techniques, but as expected none us them is without defects. However they can probably be used in synergy. Overall for the pharmacist willing to get involved, the implementation of the control for chemotherapies preparations must be widely anticipated, with the listing of every parameter, and remains according to us an analyst's job. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Experimental design and multiple response optimization. Using the desirability function in analytical methods development.

    Science.gov (United States)

    Candioti, Luciana Vera; De Zan, María M; Cámara, María S; Goicoechea, Héctor C

    2014-06-01

    A review about the application of response surface methodology (RSM) when several responses have to be simultaneously optimized in the field of analytical methods development is presented. Several critical issues like response transformation, multiple response optimization and modeling with least squares and artificial neural networks are discussed. Most recent analytical applications are presented in the context of analytLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, ArgentinaLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, Argentinaical methods development, especially in multiple response optimization procedures using the desirability function. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Analytical methods used at IPR (Instituto de Pesquisas Radioativas - Minas Gerais, Brazil)

    International Nuclear Information System (INIS)

    Murta, C.C.

    The analytical methods available at IPR (MG-Brazil) for the routine determination of uranium are described. These methods are: gravimetric analysis; fluorescence spectroscopy, voltametry, polarography, absorption spectroscopy, beta-and gamma-radiometric analysis, gamma spectroscopy, activation analysis, X-rays fluorescence analysis and delayed neutron analysis. Some additional methods for the study of mineral ores, such as X-rays diffractometry, emmission spectroscopy, thermal analysis, etc, are also discussed [pt

  17. Analytical Method Validation and Quality Control of a Seven-Herb Chinese Medicine Formulation Used for the Treatment of Irritable Bowel Syndrome with Constipation.

    Science.gov (United States)

    Bourchier, Suzannah J; Bensoussan, Alan; Lee, Samiuela; Pearson, Jarryd L; Khoo, Cheang S

    2016-03-24

    There is a need for increased QC of complex herbal medicine formulations to ensure product consistency, efficacy, and safety. This study reports an HPLC with photodiode array and electrospray ionization-tandem MS method for quantifying selected analytes in a seven-herb formulation. Fourteen analytes were selected for quantification based on the criteria available from the Herbal Chemical Marker Ranking System, which takes into account the bioavailability, reported bioactivity, and physiological action related to its intended use, as well as commercial availability of the standard. After optimizing the columns and chromatographic conditions, 13 of the 14 analytes were able to be determined in one run, with the remaining analyte analyzed on its own. The method was successfully applied to two different extracts of the formulation, demonstrating an application for the QC of a complex herbal mixture with respect to their chemical characteristics.

  18. Toward a standard method for determination of waterborne radon

    International Nuclear Information System (INIS)

    Vitz, E.

    1990-01-01

    When the USEPA specifies the maximum contaminant level (MCL) for any contaminant, a standard method for analysis must be simultaneously stipulated. Promulgation of the proposed MCL and standard method for radon in drinking water is expected by early next year, but a six-month comment period and revision will precede final enactment. The standard method for radon in drinking water will probably specify that either the Lucas cell technique or liquid scintillation spectrometry be used. This paper reports results which support a standard method with the following features: samples should be collected by an explicitly stated technique to control degassing, in glass vials with or without scintillation cocktail, and possibly in duplicate; samples should be measured by liquid scintillation spectroscopy in a specified energy window', in a glass vial with particular types of cocktails; radium standards should be prepared with controlled quench levels and specified levels of carriers, but radium-free controls prepared by a specified method should be used in interlaboratory comparison studies

  19. Evaluation of Molecular Markers and Analytical Methods Documenting the Occurrence of Mustard Gas and Arsenical Warfare Agents in Soil.

    Science.gov (United States)

    Sassolini, Alessandro; Brinchi, Giampaolo; Di Gennaro, Antonio; Dionisi, Simone; Dominici, Carola; Fantozzi, Luca; Onofri, Giorgio; Piazza, Rosario; Guidotti, Maurizio

    2016-09-01

    The chemicals warfare agents (CWAs) are an extremely toxic class of molecules widely produced in many industrialized countries for decades, these compounds frequently contained arsenic. The plants where the CWAs have been produced or the plants where they have been demilitarized after the Second World War with unacceptable techniques can represent a serious environmental problem. CWAs standards are difficult to find on market so in present work an environmental assessment method based on markers has been proposed. Triphenylarsine, phenylarsine oxide and thiodiglycol have been selected as markers. Three reliable analytical methods based on gaschromatography and mass detection have been proposed and tested for quantitative analysis of markers. Methods performance have been evaluated testing uncertainty, linearity, recovery and detection limits and also comparing detection limits with exposure limits of reference CWAs. Proposed assessment methods have been applied to a case study of a former industrial plant sited in an area characterized by a high background of mineral arsenic.

  20. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  1. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard Test Method for Measured Speed of Oil Diffusion Pumps

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the determination of the measured speed (volumetric flow rate) of oil diffusion pumps. 1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard Test Method for Determining Poisson's Ratio of Honeycomb Cores

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the honeycomb Poisson's ratio from the anticlastic curvature radii, see . 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Standard Test Method for Shear Fatigue of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers determination of the effect of repeated shear loads on sandwich core materials. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard Test Method for Dimensional Stability of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the sandwich core dimensional stability in the two plan dimensions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Solution of the isotopic depletion equation using decomposition method and analytical solution

    Energy Technology Data Exchange (ETDEWEB)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: fprata@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@lmp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  7. Solution of the isotopic depletion equation using decomposition method and analytical solution

    International Nuclear Information System (INIS)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S.

    2011-01-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  8. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    Science.gov (United States)

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  10. Are Randomized Controlled Trials the (G)old Standard? From Clinical Intelligence to Prescriptive Analytics

    Science.gov (United States)

    2016-01-01

    Despite the accelerating pace of scientific discovery, the current clinical research enterprise does not sufficiently address pressing clinical questions. Given the constraints on clinical trials, for a majority of clinical questions, the only relevant data available to aid in decision making are based on observation and experience. Our purpose here is 3-fold. First, we describe the classic context of medical research guided by Poppers’ scientific epistemology of “falsificationism.” Second, we discuss challenges and shortcomings of randomized controlled trials and present the potential of observational studies based on big data. Third, we cover several obstacles related to the use of observational (retrospective) data in clinical studies. We conclude that randomized controlled trials are not at risk for extinction, but innovations in statistics, machine learning, and big data analytics may generate a completely new ecosystem for exploration and validation. PMID:27383622

  11. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. ... residual separation to separate out residual anom- alies, which are interpreted for geological .... terms, which are used for the semi-quantitative interpretation. 6.1 Computation of ...

  12. Materials of the Second Sumy-Cracow-Muenster Symposium on Nuclear Analytical Methods

    International Nuclear Information System (INIS)

    2001-01-01

    The applications of nuclear analytical methods in physico-chemical, biological and medical studies have been presented in large number of applications. Environmental, geological and biological materials have been analysed by means of neutron activation analysis, proton microprobe, x-ray diffraction, synchrotron radiation X-ray spectrum analysis, ESR and others

  13. Analytical methods for an elliptic singular perturbation problem In a circle

    NARCIS (Netherlands)

    N.M. Temme (Nico)

    2007-01-01

    textabstractWe consider an elliptic perturbation problem in a circle by using the analytical solution that is given by a Fourier series with coefficients in terms of modified Bessel functions. By using saddle point methods we construct asymptotic approximations with respect to a small parameter.

  14. New neutron-based isotopic analytical methods; An explorative study of resonance capture and incoherent scattering

    NARCIS (Netherlands)

    Perego, R.C.

    2004-01-01

    Two novel neutron-based analytical techniques have been treated in this thesis, Neutron Resonance Capture Analysis (NRCA), employing a pulsed neutron source, and Neutron Incoherent Scattering (NIS), making use of a cold neutron source. With the NRCA method isotopes are identified by the

  15. Semi-Analytical Weight Estimation Method for Fuselages with Oval Cross-Section

    NARCIS (Netherlands)

    Vos, R.; Hoogreef, M.F.M.

    2013-01-01

    This paper presents a semi-analytical method for the weight estimation of fuselages with an oval cross-section, applied to blended wing body aircraft. The weight estimation of the fuselage primary structure is based on a structural analysis of two-dimensional crosssections and it is completed by a

  16. A semi-analytical method for simulating matrix diffusion in numerical transport models.

    Science.gov (United States)

    Falta, Ronald W; Wang, Wenwen

    2017-02-01

    A semi-analytical approximation for transient matrix diffusion is developed for use in numerical contaminant transport simulators. This method is an adaptation and extension of the heat conduction method of Vinsome and Westerveld (1980) used to simulate heat losses during thermally enhanced oil recovery. The semi-analytical method is used in place of discretization of the low permeability materials, and it represents the concentration profile in the low permeability materials with a fitting function that is adjusted in each element at each time-step. The resulting matrix diffusion fluxes are added to the numerical model as linear concentration-dependent source/sink terms. Since only the high permeability zones need to be discretized, the numerical formulation is extremely efficient compared to traditional approaches that require discretization of both the high and low permeability zones. The semi-analytical method compares favorably with the analytical solution for transient one-dimensional diffusion with first order decay, with a two-layer aquifer/aquitard solution, with the solution for transport in a fracture with matrix diffusion and decay, and with a fully numerical solution for transport in a thin sand zone bounded by clay with variable decay rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Analytical Method to Calculate the DC Link Current Stress in Voltage Source Converters

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2014-01-01

    for the applications with high line current ripple. The effect of the pulsewidth modulation (PWM) scheme on the rms value of the dc-link current is also studied and the analysis for continuous PWM and discontinuous PWM (DPWM) schemes is presented. The proposed analytical method is also verified experimentally....

  18. Nuclear analytical methods in teaching and research at the university of Illinois

    International Nuclear Information System (INIS)

    Landsberger, S.

    1994-01-01

    An overview of the nuclear analytical methods opportunities at the University of Illinois at Urbana-Champaign are given. Undergraduate and graduate level teaching and research are highlighted. The TRIGA reactor and neutron activation analysis facilities are described in the context of this role within an inter-disciplinary environment. (author)

  19. Knowledge, Skills, and Abilities for Entry-Level Business Analytics Positions: A Multi-Method Study

    Science.gov (United States)

    Cegielski, Casey G.; Jones-Farmer, L. Allison

    2016-01-01

    It is impossible to deny the significant impact from the emergence of big data and business analytics on the fields of Information Technology, Quantitative Methods, and the Decision Sciences. Both industry and academia seek to hire talent in these areas with the hope of developing organizational competencies. This article describes a multi-method…

  20. Vertical equilibrium with sub-scale analytical methods for geological CO2 sequestration

    KAUST Repository

    Gasda, S. E.

    2009-04-23

    Large-scale implementation of geological CO2 sequestration requires quantification of risk and leakage potential. One potentially important leakage pathway for the injected CO2 involves existing oil and gas wells. Wells are particularly important in North America, where more than a century of drilling has created millions of oil and gas wells. Models of CO 2 injection and leakage will involve large uncertainties in parameters associated with wells, and therefore a probabilistic framework is required. These models must be able to capture both the large-scale CO 2 plume associated with the injection and the small-scale leakage problem associated with localized flow along wells. Within a typical simulation domain, many hundreds of wells may exist. One effective modeling strategy combines both numerical and analytical models with a specific set of simplifying assumptions to produce an efficient numerical-analytical hybrid model. The model solves a set of governing equations derived by vertical averaging with assumptions of a macroscopic sharp interface and vertical equilibrium. These equations are solved numerically on a relatively coarse grid, with an analytical model embedded to solve for wellbore flow occurring at the sub-gridblock scale. This vertical equilibrium with sub-scale analytical method (VESA) combines the flexibility of a numerical method, allowing for heterogeneous and geologically complex systems, with the efficiency and accuracy of an analytical method, thereby eliminating expensive grid refinement for sub-scale features. Through a series of benchmark problems, we show that VESA compares well with traditional numerical simulations and to a semi-analytical model which applies to appropriately simple systems. We believe that the VESA model provides the necessary accuracy and efficiency for applications of risk analysis in many CO2 sequestration problems. © 2009 Springer Science+Business Media B.V.

  1. Statistical benchmarking in utility regulation: Role, standards and methods

    International Nuclear Information System (INIS)

    Newton Lowry, Mark; Getachew, Lullit

    2009-01-01

    Statistical benchmarking is being used with increasing frequency around the world in utility rate regulation. We discuss how and where benchmarking is in use for this purpose and the pros and cons of regulatory benchmarking. We then discuss alternative performance standards and benchmarking methods in regulatory applications. We use these to propose guidelines for the appropriate use of benchmarking in the rate setting process. The standards, which we term the competitive market and frontier paradigms, have a bearing on method selection. These along with regulatory experience suggest that benchmarking can either be used for prudence review in regulation or to establish rates or rate setting mechanisms directly

  2. The riddle of Siegfried: exploring methods and psychological perspectives in analytical psychology.

    Science.gov (United States)

    Barreto, Marco Heleno

    2016-02-01

    Jung's dream of the killing of Siegfried poses a riddle: why did the unconscious choose precisely Siegfried as the hero to be murdered? Jung himself declares that he does not know. This paper attempts to decipher this riddle using three distinct methodological approaches accepted by Jung, two of them in fact grounded in his theories of dream interpretation. Besides presenting some possible answers to the riddle of Siegfried, this interpretative reflection brings to light the discrepancy of the psychological perspectives created by the heterogeneity of methods within analytical psychology. © 2016, The Society of Analytical Psychology.

  3. Evaluation of the effect of coal cleaning of fugitive elements. Part II. Analytical methods. Final report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Bosshart, R.E.; Price, A.A.; Ford, C.T.

    1980-03-01

    This report contains the analytical and test methods which were used routinely at Bituminous Coal Research, Inc. during the project. The procedures contained herein should aid coal industry laboratories and others, including commercial laboratories, who might be required to determine trace elements in coal. Some of the procedures have been presented in previous BCR reports; however, this report includes additional procedures which are described in greater detail. Also presented are many as the more basic coal methods which have been in use at BCR for many years, or which have been adapted or refined from other standard reference sources for coal and water. The basis for choosing specific analytical procedures for trace elements in coal is somewhat complex. At BCR, atomic absorption was selected as the basic method in the development of these procedures. The choice was based on sensitivity, selectivity, accuracy, precision, practicability, and economy. Whenever possible, the methods developed had to be both adequate and amenable for use by coal industry laboratories by virtue of relative simplicity and cost. This is not to imply that the methods described are simple or inexpensive; however, atomic abosrption techniques do meet these criteria in relation to more complex and costly methods such as neutron activation, mass spectrometry, and x-ray fluorescence, some of which require highly specialized personnel as well as access to sophisticated nuclear and computational facilities. Many of the analytical procedures for trace elements in coal have been developed or adapted specifically for the BCR studies. Their presentation is the principal purpose of this report.

  4. Development and validation of an analytical method for quality control and the stability of the eyedrops 10 % Phenylephrine and the 1 % Tropicamide

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad Margarita; Botet Garcia, Martha; Troche Concepcion, Yenilen

    2011-01-01

    An analytical high-performance liquid chromatography method was developed and validated applicable to quality control and to stability study of 10 % phenylephrine plus eyedrops 1 % tropicamide. To quantify simultaneously both active principles in the finished product, separation was carried out through a Lichrosorb RP-18 (15 μm) (260 x 4 mm) column chromatography, with ultraviolet detection at 253 nm using the mobile phase composed of methanol: distilled water (1:1), with 1.1 g of sodium 1-octasulfanate by litre and pH fitted to 3.0 with phosphoric acid and the quantification of this front to a reference sample using the external standard method. The analytical method developed was linear, precise, specific and accurate in the rank of study concentrations, established for the quality control and stability study of the finished product since there were not analytical methods designed for these aims

  5. Comparison of potential method in analytic hierarchy process for multi-attribute of catering service companies

    Science.gov (United States)

    Mamat, Siti Salwana; Ahmad, Tahir; Awang, Siti Rahmah

    2017-08-01

    Analytic Hierarchy Process (AHP) is a method used in structuring, measuring and synthesizing criteria, in particular ranking of multiple criteria in decision making problems. On the other hand, Potential Method is a ranking procedure in which utilizes preference graph ς (V, A). Two nodes are adjacent if they are compared in a pairwise comparison whereby the assigned arc is oriented towards the more preferred node. In this paper Potential Method is used to solve problem on a catering service selection. The comparison of result by using Potential method is made with Extent Analysis. The Potential Method is found to produce the same rank as Extent Analysis in AHP.

  6. Three higher order analytical nodal methods for multigroup neutron diffusion equations

    International Nuclear Information System (INIS)

    Guessous, Najib

    2016-01-01

    Highlights: • The highlight is to demonstrate efficiency of the three nodal methods developed in this work: PCANM-2, FANM-2 and RFANM-2. • It is proved that the third method is more competitive than the two others methods. • It is demonstrated that RFANM-2 can give very accurate results compared to others nodal methods from published works. - Abstract: This work presents three efficient higher order analytical nodal methods for the numerical solution of a two-dimensional multigroup neutron diffusion equation in Cartesian geometry based on the use of the successive polynomial-weighted transverse integrations technique to convert a one-group diffusion equation to a system of coupled one-dimensional ordinary differential equations. These equations are then solved analytically over each homogenized cell after adequate approximations of the resulting effective sources after transversal integrations. Coupling between the approximate transverse flux-moments is achieved by imposing uniqueness constraint on their moments values. Adjacent elements are coupled by enforcing continuity conditions on the flux and current moments at interfaces cells. The weighted cell-balance equations and current-continuity conditions are then used to derive the discrete equations. These methods are applied for solving numerically various 2D benchmark problems and theirs performances discussed. Numerical results demonstrates more efficiency for the third higher order analytical nodal method for which the alone unknowns considered are the transverse flux moments on the interfaces of the homogenized elements.

  7. Analytical synthetic methods of solution of neutron transport equation with diffusion theory approaches energy multigroup

    International Nuclear Information System (INIS)

    Moraes, Pedro Gabriel B.; Leite, Michel C.A.; Barros, Ricardo C.

    2013-01-01

    In this work we developed a software to model and generate results in tables and graphs of one-dimensional neutron transport problems in multi-group formulation of energy. The numerical method we use to solve the problem of neutron diffusion is analytic, thus eliminating the truncation errors that appear in classical numerical methods, e.g., the method of finite differences. This numerical analytical method increases the computational efficiency, since they are not refined spatial discretization necessary because for any spatial discretization grids used, the numerical result generated for the same point of the domain remains unchanged unless the rounding errors of computational finite arithmetic. We chose to develop a computational application in MatLab platform for numerical computation and program interface is simple and easy with knobs. We consider important to model this neutron transport problem with a fixed source in the context of shielding calculations of radiation that protects the biosphere, and could be sensitive to ionizing radiation

  8. Simulation of Lamb wave reflections at plate edges using the semi-analytical finite element method.

    Science.gov (United States)

    Ahmad, Z A B; Gabbert, U

    2012-09-01

    In typical Lamb wave simulation practices, effects of plate edge reflections are often not considered in order to simplify the wave signal interpretations. Methods that are based on infinite plates such as the semi-analytical finite element method is effective in simulating Lamb waves as it excludes the effect of plate edges. However, the inclusion of plate edges in a finite plate could render this method inapplicable, especially for transient response simulations. Here, by applying the ratio of Lamb mode reflections at plate edges, and representing the reflection at plate edges using infinite plate solutions, the semi-analytical finite element method can be applied for transient response simulation, even when the plate is no longer infinite. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  9. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  10. Predictive ability of the feeding system in Iberian pig by means of several analytical methods

    Directory of Open Access Journals (Sweden)

    González, E.

    2013-04-01

    Full Text Available The reliability of several analytical methods proposed to predict the feeding system received by Iberian pigs during the fattening period has been contrasted. Samples of subcutaneous adipose tissue were analyzed from 38 batches of pigs fattened in three seasons of montanera (acorn and pastures feeding. They corresponded to the four categories described in the Quality Standard for Iberian pig products: 251 samples of bellota, 164 of recebo, 197 of cebo de campo and 137 of cebo. To perform the study, the following analytical methods were used: fatty acid quantification, NIR, alpha and gamma tocopherol, chemical sensor, triacilglycerides, stable isotopes and neophytadiene. The laboratories received the samples without any information about the fattening system to which they belonged and remitted their predictions with respect to the above categories. The results showed a high percentage of accurate predictions of the methods when the fattening type corresponds to the extreme categories (bellota and cebo, however, the methods had difficulty in discerning between samples from a mixed feeding regime with acorn and feed (recebo and problems when pigs are fattened with compound feeds including vegetable fats with high levels of oleic acid. Although a simplification into only two categories (cebo/campo and recebo/bellota results in a success rate higher than 90% for some methods, the combination of two or three techniques with problematic samples allows for differentiating among the four categories with the same accuracy.Se ha contrastado la fiabilidad de varios métodos analíticos para determinar el tipo de alimentación recibida durante el cebo por cerdos Ibéricos a partir de muestras de tejido adiposo subcutáneo, procedentes de 38 partidas de cerdos de tres campañas de montanera. Las muestras correspondieron con las categorías de alimentación contempladas en la Norma de Calidad: 251 fueron de bellota, 164 de recebo, 197 de campo y 137 de cebo

  11. Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study

    OpenAIRE

    Ravi Kumar Konda; Babu Rao Chandu; B.R. Challa; Chandrasekhar B. Kothapalli

    2012-01-01

    The most suitable bio-analytical method based on liquidâliquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mmÃ50 mm, 3.5 μm) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ion...

  12. Comprehension of complex biological processes by analytical methods: how far can we go using mass spectrometry?

    International Nuclear Information System (INIS)

    Gerner, C.

    2013-01-01

    Comprehensive understanding of complex biological processes is the basis for many biomedical issues of great relevance for modern society including risk assessment, drug development, quality control of industrial products and many more. Screening methods provide means for investigating biological samples without research hypothesis. However, the first boom of analytical screening efforts has passed and we again need to ask whether and how to apply screening methods. Mass spectrometry is a modern tool with unrivalled analytical capacities. This applies to all relevant characteristics of analytical methods such as specificity, sensitivity, accuracy, multiplicity and diversity of applications. Indeed, mass spectrometry qualifies to deal with complexity. Chronic inflammation is a common feature of almost all relevant diseases challenging our modern society; these diseases are apparently highly diverse and include arteriosclerosis, cancer, back pain, neurodegenerative diseases, depression and other. The complexity of mechanisms regulating chronic inflammation is the reason for the practical challenge to deal with it. The presentation shall give an overview of capabilities and limitations of the application of this analytical tool to solve critical questions with great relevance for our society. (author)

  13. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  14. A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens

    OpenAIRE

    Cristina Portalés; Sergio Casas; Inmaculada Coma; Marcos Fernández

    2017-01-01

    The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, w...

  15. A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens

    OpenAIRE

    Portalés Ricart, Cristina; Casas Yrurzum, Sergio; Coma Tatay, Inmaculada; Fernández Marín, Marcos

    2017-01-01

    The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, w...

  16. Precision of a plutonium analytical method using solvent extraction and spectrophotometry

    International Nuclear Information System (INIS)

    Mendoza, P.G.; Jackson, D.D.; Niemczyk, T.M.

    1991-01-01

    The plutonium assay method was investigated that uses the plutonyl trinitrate tetrapropyl-ammonium ion-pair solvent extraction with spectrophotometry of the extract as a candidate method capable of providing robustness and precision. To identify and asses the effect of factors on the precision, we looked at sampling techniques, silver oxide oxidation conditions extraction time, extract stability, and temperature dependence of the extract analytical peak height and position. A precision of 0.12% was obtained. (author) 18 refs.; 2 figs

  17. Analytical methods for drinking water; Metodi di analisi per le acque destinate al consumo umano

    Energy Technology Data Exchange (ETDEWEB)

    Ottaviani, Massimo; Bonadonna, Lucia [Istituto Superiore di Sanita`, Rome (Italy). Lab. di Igiene Ambientale

    1997-03-01

    These analytical methods for drinking water were elaborated by the second Sub-commission of the Permanent study committee ex-article 9 of Italian Ministerial Decree (DM) of March 26, 1991, established at the Ministry of Health. The methods concern the chemical and microbiological parameters included in the C1, C2 and C3 controls of the Annex II of the Decree of the President of the Republic (DPR) 236/88.

  18. A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison

    Science.gov (United States)

    2017-03-01

    This complex connectivity between the drive components was found to be very difficult to model using traditional finite- element methods...components of the ARES could be accurately modeled using finite- elements , modeling the connectivity between the components was found to be significantly...ARL-RP-0592 ● Mar 2017 US Army Research Laboratory A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison by Robert P

  19. Fault feature analysis of cracked gear based on LOD and analytical-FE method

    Science.gov (United States)

    Wu, Jiateng; Yang, Yu; Yang, Xingkai; Cheng, Junsheng

    2018-01-01

    At present, there are two main ideas for gear fault diagnosis. One is the model-based gear dynamic analysis; the other is signal-based gear vibration diagnosis. In this paper, a method for fault feature analysis of gear crack is presented, which combines the advantages of dynamic modeling and signal processing. Firstly, a new time-frequency analysis method called local oscillatory-characteristic decomposition (LOD) is proposed, which has the attractive feature of extracting fault characteristic efficiently and accurately. Secondly, an analytical-finite element (analytical-FE) method which is called assist-stress intensity factor (assist-SIF) gear contact model, is put forward to calculate the time-varying mesh stiffness (TVMS) under different crack states. Based on the dynamic model of the gear system with 6 degrees of freedom, the dynamic simulation response was obtained for different tooth crack depths. For the dynamic model, the corresponding relation between the characteristic parameters and the degree of the tooth crack is established under a specific condition. On the basis of the methods mentioned above, a novel gear tooth root crack diagnosis method which combines the LOD with the analytical-FE is proposed. Furthermore, empirical mode decomposition (EMD) and ensemble empirical mode decomposition (EEMD) are contrasted with the LOD by gear crack fault vibration signals. The analysis results indicate that the proposed method performs effectively and feasibility for the tooth crack stiffness calculation and the gear tooth crack fault diagnosis.

  20. Analytical and Numerical Tooth Contact Analysis (TCA of Standard and Modified Involute Profile Spur Gear

    Directory of Open Access Journals (Sweden)

    Nassear Rasheid Hmoad

    2016-03-01

    Full Text Available Among all the common mechanical transmission elements, gears still playing the most dominant role especially in the heavy duty works offering extraordinary performance under extreme conditions and that the cause behind the extensive researches concentrating on the enhancement of its durability to do its job as well as possible. Contact stress distribution within the teeth domain is considered as one of the most effective parameters characterizing gear life, performance, efficiency, and application so that it has been well sought for formal gear profiles and paid a lot of attention for moderate tooth shapes. The aim of this work is to investigate the effect of pressure angle, speed ratio, and correction factor on the maximum contact and bending stress value and principal stresses distribution for symmetric and asymmetric spur gear. The analytical investigation adopted Hertz equations to find the contact stress value, distribution, and the contact zone width while the numerical part depends on Ansys software version 15, as a FE solver with Lagrange and penalty contact algorithm. The most fruitful points to be noticed are that the increasing of pressure angle and speed ratio trends to minimize all the induced stresses for the classical gears and the altered teeth shape with larger loaded side pressure angle than the unloaded side one behave better than the symmetric teeth concerning the stress reduction.

  1. Robust steganographic method utilizing properties of MJPEG compression standard

    Directory of Open Access Journals (Sweden)

    Jakub Oravec

    2015-06-01

    Full Text Available This article presents design of steganographic method, which uses video container as cover data. Video track was recorded by webcam and was further encoded by compression standard MJPEG. Proposed method also takes in account effects of lossy compression. The embedding process is realized by switching places of transform coefficients, which are computed by Discrete Cosine Transform. The article contains possibilities, used techniques, advantages and drawbacks of chosen solution. The results are presented at the end of the article.

  2. Approximate Analytical Solutions of Fractional Perturbed Diffusion Equation by Reduced Differential Transform Method and the Homotopy Perturbation Method

    OpenAIRE

    Zhoujin Cui; Zisen Mao; Sujuan Yang; Pinneng Yu

    2013-01-01

    The approximate analytical solutions of differential equations with fractional time derivative are obtained with the help of a general framework of the reduced differential transform method (RDTM) and the homotopy perturbation method (HPM). RDTM technique does not require any discretization, linearization, or small perturbations and therefore it reduces significantly the numerical computation. Comparing the methodology (RDTM) with some known technique (HPM) shows that the present approach is ...

  3. Report on the Standardization Project "Formal Methods in Conformance Testing"

    NARCIS (Netherlands)

    Baumgarten, B.; Hogrefe, D.; Heymer, S.; Burkhardt, H.-J.; Giessler, A.; Tretmans, G.J.

    1996-01-01

    This paper presents the latest developments in the “Formal Methods in Conformance Testing��? (FMCT) project of ISO and ITU–T. The project has been initiated to study the role of formal description techniques in the conformance testing process. The goal is to develop a standard that defines the

  4. Standard methods for rearing and selection of Apis mellifera queens

    DEFF Research Database (Denmark)

    Büchler, Ralph; Andonov, Sreten; Bienefeld, Kaspar

    2013-01-01

    Here we cover a wide range of methods currently in use and recommended in modern queen rearing, selection and breeding. The recommendations are meant to equally serve as standards for both scientific and practical beekeeping purposes. The basic conditions and different management techniques for q...

  5. Evaluating the Capacity of Standard Investment Appraisal Methods

    NARCIS (Netherlands)

    M.M. Akalu

    2002-01-01

    textabstractThe survey findings indicate the existence of gap between theory and practice of capital budgeting. Standard appraisal methods have shown a wider project value discrepancy, which is beyond and above the contingency limit. In addition, the research has found the growing trend in the use

  6. Internal standard method for the determination of Gold and the ...

    African Journals Online (AJOL)

    Olof Vorster

    demand the world over for gold (Au) and the platinum group metals (PGMs) consisting of Pt, Pd, Ru, Rh, Ir and Os. Inductively coupled plasma optical emission spectrometry (ICP-OES) is widely used for the quantitative analysis of the PGMs using the internal standardization method.2,9. Although interferences are less of a.

  7. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Rapid Quantification of Melamine in Different Brands/Types of Milk Powders Using Standard Addition Net Analyte Signal and Near-Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Bang-Cheng Tang

    2016-01-01

    Full Text Available Multivariate calibration (MVC and near-infrared (NIR spectroscopy have demonstrated potential for rapid analysis of melamine in various dairy products. However, the practical application of ordinary MVC can be largely restricted because the prediction of a new sample from an uncalibrated batch would be subject to a significant bias due to matrix effect. In this study, the feasibility of using NIR spectroscopy and the standard addition (SA net analyte signal (NAS method (SANAS for rapid quantification of melamine in different brands/types of milk powders was investigated. In SANAS, the NAS vector of melamine in an unknown sample as well as in a series of samples added with melamine standards was calculated and then the Euclidean norms of series standards were used to build a straightforward univariate regression model. The analysis results of 10 different brands/types of milk powders with melamine levels 0~0.12% (w/w indicate that SANAS obtained accurate results with the root mean squared error of prediction (RMSEP values ranging from 0.0012 to 0.0029. An additional advantage of NAS is to visualize and control the possible unwanted variations during standard addition. The proposed method will provide a practically useful tool for rapid and nondestructive quantification of melamine in different brands/types of milk powders.

  9. Characterization of Some Real Mixed Plastics from WEEE: A Focus on Chlorine and Bromine Determination by Different Analytical Methods

    Directory of Open Access Journals (Sweden)

    Beatrice Beccagutti

    2016-10-01

    Full Text Available Bromine and chlorine are almost ubiquitous in waste of electrical and electronic equipment (WEEE and the knowledge of their content in the plastic fraction is an essential step for proper end of life management. The aim of this study is to compare the following analytical methods: energy dispersive X-ray fluorescence spectroscopy (ED-XRF, ion chromatography (IC, ion-selective electrodes (ISEs, and elemental analysis for the quantitative determination of chlorine and bromine in four real samples taken from different WEEE treatment plants, identifying the best analytical technique for waste management workers. Home-made plastic standard materials with known concentrations of chlorine or bromine have been used for calibration of ED-XRF and to test the techniques before the sample analysis. Results showed that IC and ISEs, based upon dissolution of the products of the sample combustion, have not always achieved a quantitative absorption of the analytes in the basic solutions and that bromine could be underestimated since several oxidation states occur after combustion. Elemental analysis designed for chlorine determination is subjected to strong interference from bromine and required frequent regeneration and recalibration of the measurement cell. The most reliable method seemed to be the non-destructive ED-XRF. Calibration with home-made standards, having a similar plastic matrix of the samples, enabled us to carry out quantitative determinations, which have been revealed to be satisfactorily accurate and precise. In all the analyzed samples a total concentration of chlorine and/or bromine between 0.6 and 4 w/w% was detected, compromising the feasibility of a mechanical recycling and suggesting the exploration of an alternative route for managing these plastic wastes.

  10. Adequacy and validation of an analytical method for the quantification of lead in chamomile tisanes produced in Costa Rica

    International Nuclear Information System (INIS)

    Blanco Barrantes, Jeimy

    2014-01-01

    An analytical methodology is developed and validated to quantify lead in chamomile tisanes. Lead is quantified by utilizing the technique of flame atomic absorption spectroscopy in three brands of chamomile tisanes sold in Costa Rica to determine its safety and quality based on international standards. A method of sample preparation is established through a comparison of different forms of extraction. The acid digestion extraction method has been the procedure utilized, reaching an average recovery percentage of 97,1%, with a standard deviation of 2,3%. The optimization of the chosen analytical procedure and complete validation is performed. The results obtained in the validation of the analytical procedure have shown that the interval where is generated the best calibration curve in terms of the correlation coefficient and the value of the statistically significant intercept equal to zero, have been the comprised between (0,2-3,2) μg/mL (r 2 =0,9996), corresponding to a range between 20% to 320% of the maximum allowed limit. In addition, the procedure has been adequate in terms of accuracy (average recovery percentage 101,1%) and precision under repeatability and intermediate precision (RSD max. 9,3%) and limit of quantification (0,2551 μg/mL). The safety criterion of World Health Organization (WHO) is determined with respect to the concentration of lead in the analyzed products. The 9 analyzed samples of products to prepare chamomile tisanes have stayed without evidencing concentrations of lead above the limit value of 10 μg/g suggested for medicinal herbs by WHO [es

  11. Mathematical model of complex technical asymmetric system based on numerical-analytical boundary elements method

    Directory of Open Access Journals (Sweden)

    Dina V. Lazareva

    2015-06-01

    Full Text Available A new mathematical model of asymmetric support structure frame type is built on the basis of numerical-analytical boundary elements method (BEM. To describe the design scheme used is the graph theory. Building the model taken into account is the effect of frame members restrained torsion, which presence is due to the fact that these elements are thin-walled. The built model represents a real object as a two-axle semi-trailer platform. To implement the BEM algorithm obtained are analytical expressions of the fundamental functions and vector load components. The effected calculations are based on the semi-trailer two different models, using finite elements and boundary elements methods. The analysis showed that the error between the results obtained on the basis of two numerical methods and experimental data is about 4%, that indicates the adequacy of the proposed mathematical model.

  12. Validation of an analytical method for quality control and stability study of 10 % Phenylephrine eyedrops

    International Nuclear Information System (INIS)

    Monteagudo Licea, Raiza; Garcia Penna, Caridad Margarita; Botet Garcia, Martha

    2010-01-01

    Phenylephrine is used like mydiatric in eye examinations and other ophthalmic procedures. It is used as vasoconstrictor with local anesthetic agents. In present paper a high resolution liquid chromatography analytical method was validated to quality control and stability studies of 10 % Phenylephrine (eyedrops). Method was based in separation of active principle through a Lichrosorb RO-18 (5 μm) (250 x 4 mm) chromatography column with UV detection at 280 nm using a mobile phase composed by a non-gasified mixture of methanol distilled water (1:1) with 1.1 g of 1-sodium octane-sulphonate by liter adjusted to pH 3,0 with phosphoric acid at a flow speed of 1.0 mL/min. Analytical method was linear, accuracy, specific and exact in the interval of study concentrations

  13. Validation of analytical method for quality control of B12 Vitamin-10 000 injection

    International Nuclear Information System (INIS)

    Botet Garcia, Martha; Garcia Penna, Caridad Margarita; Troche Concepcion, Yenilen; Cannizares Arencibia, Yanara; Moreno Correoso, Barbara

    2009-01-01

    Analytical method reported by USA Pharmacopeia was validated for quality control of injectable B 1 2 Vitamin (10 000 U) by UV spectrophotometry because this is a simpler and low-cost method allowing quality control of finished product. Calibration curve was graphed at 60 to 140% interval, where it was linear with a correlation coefficient similar to 0, 9999; statistical test for interception and slope was considered non-significant. There was a recovery of 99.7 % in study concentrations interval where the Cochran (G) and Student(t) test were not significant too. Variation coefficient in repetition study was similar to 0.59 % for the 6 assayed replies, whereas in intermediate precision analysis, the Fisher and Student tests were not significant. Analytical method was linear, precise, specific and exact in study concentrations interval

  14. Analytical method validation for quality control and the study of the 50 mg Propylthiouracil stability

    International Nuclear Information System (INIS)

    Valdes Bendoyro, Maria Olga; Garcia Penna, Caridad Margarita; Fernandez, Juan Lugones; Garcia Borges, Lisandra; Martinez Espinosa, Vivian

    2010-01-01

    A high-performance liquid chromatography analytical method was developed and validated for the quality control and stability studies of 50 mg Propylthiouracil tablets. Method is based in active principle separation through a 100 RP-18 RP-18 (5 μm) (250 x 4 mm) Lichrospher chromatography with UV detection to 272 nm, using a mobile phase composed by a ungaseous mixture of a 0.025 M buffer solution-monobasic potassium phosphate to pH= 4,6 ad acetonitrile in a 80:20 ratio with a flux speed of 0,5 mL/min. Analytical method was linear, precise, specific and exact in the study concentrations interval

  15. Besifloxacin: A Critical Review of Its Characteristics, Properties, and Analytical Methods.

    Science.gov (United States)

    Tótoli, Eliane Gandolpho; Salgado, Hérida Regina Nunes

    2018-03-04

    Bacterial conjunctivitis has high impact on the health of the population, since it represents more than a third of ocular pathologies reported by health services worldwide. There is a high incidence of bacterial resistance to the antimicrobials most commonly used for the treatment of conjunctivitis. In this context, besifloxacin stands out, since it is a fluoroquinolone developed exclusively for topical ophthalmic use, presenting a low risk of developing resistance due to its reduced systemic exposure. Bausch & Lomb markets it as ophthalmic suspension, under the trade name Besivance™. Literature review on besifloxacin is presented, covering its pharmaceutical and clinical characteristics, and the analytical methods used to measure the drug in pharmaceutical products and biological samples. High performance liquid chromatography is the most used method for this purpose. A discussion on Green Chemistry is also presented, focusing the importance of the development of green analytical methods for the analysis of drugs.

  16. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  17. Moxidectin residues in lamb tissues: Development and validation of analytical method by UHPLC-MS/MS.

    Science.gov (United States)

    Del Bianchi A Cruz, Michelle; Fernandes, Maria A M; de C Braga, Patricia A; Monteiro, Alda L G; Daniel, Daniela; Reyes, Felix G R

    2018-01-01

    The development and validation of a throughput method for the quantitation of moxidectin residues in lamb target tissues (muscle, kidney, liver and fat) was conducted using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). To achieve higher recovery of the analyte from the matrices, a modified QuEChERS method was used for sample preparation. The chromatographic separation was achieved using a Zorbax Eclipse Plus C18 RRHD column with a mobile phase comprising 5mM ammonium formate solution +0.1% formic acid (A) and acetonitrile +0.1% formic acid (B) in a linear gradient program. Method validation was performed based on the Commission Decision 2002/657/EC and VICH GL49. To quantify the analyte, matrix-matched analytical curves were constructed with spiked blank tissues, with a limit of quantitation of 5ngg -1 and limit of detection of 1.5ngg -1 for all matrices. The linearity, decision limit, detection capability accuracy, and inter- and intra-day repeatability of the method are reported. The method was successfully applied to incurred lamb tissue samples (muscle, liver, kidney and fat) in a concentration range from 5 to 200μgkg -1 , which demonstrated its suitability for monitoring moxidectin residues in lamb tissues in health surveillance programs, as well as for pharmacokinetics and residue depletion studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analytical methods for the determination of personal care products in human samples: an overview.

    Science.gov (United States)

    Jiménez-Díaz, I; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2014-11-01

    Personal care products (PCPs) are organic chemicals widely used in everyday human life. Nowadays, preservatives, UV-filters, antimicrobials and musk fragrances are widely used PCPs. Different studies have shown that some of these compounds can cause adverse health effects, such as genotoxicity, which could even lead to mutagenic or carcinogenic effects, or estrogenicity because of their endocrine disruption activity. Due to the absence of official monitoring protocols, there is an increasing demand of analytical methods that allow the determination of those compounds in human samples in order to obtain more information regarding their behavior and fate in the human body. The complexity of the biological matrices and the low concentration levels of these compounds make necessary the use of advanced sample treatment procedures that afford both, sample clean-up, to remove potentially interfering matrix components, as well as the concentration of analytes. In the present work, a review of the more recent analytical methods published in the scientific literature for the determination of PCPs in human fluids and tissue samples, is presented. The work focused on sample preparation and the analytical techniques employed. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Development and validation of a multi-analyte method for the regulatory control of carotenoids used as feed additives in fish and poultry feed.

    Science.gov (United States)

    Vincent, Ursula; Serano, Federica; von Holst, Christoph

    2017-08-01

    Carotenoids are used in animal nutrition mainly as sensory additives that favourably affect the colour of fish, birds and food of animal origin. Various analytical methods exist for their quantification in compound feed, reflecting the different physico-chemical characteristics of the carotenoid and the corresponding feed additives. They may be natural products or specific formulations containing the target carotenoids produced by chemical synthesis. In this study a multi-analyte method was developed that can be applied to the determination of all 10 carotenoids currently authorised within the European Union for compound feedingstuffs. The method functions regardless of whether the carotenoids have been added to the compound feed via natural products or specific formulations. It is comprised of three steps: (1) digestion of the feed sample with an enzyme; (2) pressurised liquid extraction; and (3) quantification of the analytes by reversed-phase HPLC coupled to a photodiode array detector in the visible range. The method was single-laboratory validated for poultry and fish feed covering a mass fraction range of the target analyte from 2.5 to 300 mg kg - 1 . The following method performance characteristics were obtained: the recovery rate varied from 82% to 129% and precision expressed as the relative standard deviation of intermediate precision varied from 1.6% to 15%. Based on the acceptable performance obtained in the validation study, the multi-analyte method is considered fit for the intended purpose.

  20. An analytically based numerical method for computing view factors in real urban environments

    Science.gov (United States)

    Lee, Doo-Il; Woo, Ju-Wan; Lee, Sang-Hyun

    2018-01-01

    A view factor is an important morphological parameter used in parameterizing in-canyon radiative energy exchange process as well as in characterizing local climate over urban environments. For realistic representation of the in-canyon radiative processes, a complete set of view factors at the horizontal and vertical surfaces of urban facets is required. Various analytical and numerical methods have been suggested to determine the view factors for urban environments, but most of the methods provide only sky-view factor at the ground level of a specific location or assume simplified morphology of complex urban environments. In this study, a numerical method that can determine the sky-view factors ( ψ ga and ψ wa ) and wall-view factors ( ψ gw and ψ ww ) at the horizontal and vertical surfaces is presented for application to real urban morphology, which are derived from an analytical formulation of the view factor between two blackbody surfaces of arbitrary geometry. The established numerical method is validated against the analytical sky-view factor estimation for ideal street canyon geometries, showing a consolidate confidence in accuracy with errors of less than 0.2 %. Using a three-dimensional building database, the numerical method is also demonstrated to be applicable in determining the sky-view factors at the horizontal (roofs and roads) and vertical (walls) surfaces in real urban environments. The results suggest that the analytically based numerical method can be used for the radiative process parameterization of urban numerical models as well as for the characterization of local urban climate.

  1. Milk urea analytical result reliability and its methodical possibilities in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Jan Říha

    2013-01-01

    Full Text Available Control of milk urea concentration (MUC can be used in diagnosis of the energy–nitrogen metabolism of cows. There are more analytical methods for MUC estimation and there are also discussions about their result reliability. Aim of this work was to obtain information for MUC result reliability improvement. MUC and MUN (milk urea nitrogen were investigated in 5 milk sample sets and in 7 calibration/comparison experiments. The positions of reference and indirect methods were changed in experiments. There were following analytical methods for MUC or MUN (in mg.100 ml−1: – photometric method (PH, as reference based on paradimethylaminobenzaldehyde reaction; – method Ureakvant (UK, as reference based on difference measurement of the electrical conductivity change during ureolysis; – method Chemspec (CH based on photometrical measurement of ammonia concentration after ureolysis (as reference; – spectroscopic method in mid infrared range of spectrum (FT–MIR; indirect routine method. In all methodical combinations the correlation coefficients (r varied from 0.8803 to 0.9943 (P −1 and comparable values of repeatability (from 0.65 to 1.83 mg.100 ml−1 as compared to FT–MIR MUC or MUN methods (from 1.39 to 5.6 and from 0.76 to 1.92 mg.100 ml−1 in performed experiments.

  2. Effectiveness of permethrin standard and modified methods in scabies treatment

    Directory of Open Access Journals (Sweden)

    Saleha Sungkar

    2014-06-01

    Full Text Available Background: Permethrin is the drug of choice for scabies with side effects such as erythema, pain, itching and prickling sensation. Whole-body (standard topical application of permethrin causes discomfort; thus, modified application of permethrin to the lesion only, followed with baths twice daily using soap was proposed. The objective of the study is to know the effectiveness of standard against lesion-only application of permethrin in scabies treatment.Methods: An experimental study was conducted in pesantren in East Jakarta and data was collected in May-July 2012. Diagnosis of scabies was made through anamnesis and skin examination. Subjects positive for scabies were divided into three groups: one standard method group (whole-body topical application and two modified groups (lesion-only application followed by the use of regular soap and antiseptic soap group. The three groups were evaluated weekly for three consecutive weeks. Data was processed using SPSS 20 and analyzed by Kruskal-Wallis test.Results: Total of 94 subjects was scabies positive (prevalence 50% but only 69 subjects were randomly picked to be analyzed. The cure rate at the end of week III of the standard method group was 95.7%, modified treatment followed by the use of regular soap was 91.3%, and modified treatment followed by the use of antiseptic soap was 78.3% (p = 0.163. The recurrence rate of standard treatment was 8.7%,  modified treatment followed by the use of regular soap was 13% and modified treatment followed by the use of antiseptic soap was 26.1% (p = 0.250.Conclusion: The standard scabies treatment was as effective as the modified scabies treatment.

  3. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  4. Pneumatic gouge versus standard method for iliac crest harvesting.

    Science.gov (United States)

    Duncan, R W; McGuire, R A; Meydrech, E F

    1994-08-01

    Fifty consecutive patients undergoing posterior lumbar fusion by a single surgeon were prospectively randomized in a study designed to evaluate the efficacy of using a pneumatic oscillating gouge to obtain posterior outer table iliac crest bone graft versus the standard method of using osteotomes and gouges. Variables analyzed included graft harvesting time, blood loss, weight of graft obtained, and graft site morbidity. Mean graft harvesting time with the pneumatic gouge was 1 minute 44 seconds (range, 1 min 5 sec to 3 min 15 sec) compared with the standard method time of 4 minutes 4 seconds (range, 2 min 15 sec to 8 min 56 sec) (P = 0.0001). Blood loss was also less, with a mean of 25.4 cc for the pneumatic gouge compared with 65.2 cc using the standard method (P = 0.0001). There were no complications with the graft site in either group. We conclude that the pneumatic gouge is a viable alternative to standard bone graft harvesting techniques. Benefits include shorter operative time and decreased blood loss without an increased morbidity.

  5. Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single-Standard Gas Source Multiple Collector Mass Spectrometer Method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the isotopic analysis of uranium hexafluoride (UF6) with 235U concentrations less than or equal to 5 % and 234U, 236U concentrations of 0.0002 to 0.1 %. 1.2 This test method may be applicable to the analysis of the entire range of 235U isotopic compositions providing that adequate Certified Reference Materials (CRMs or traceable standards) are available. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety health practices and determine the applicability of regulatory limitations prior to use.

  6. A finite volume method for cylindrical heat conduction problems based on local analytical solution

    KAUST Repository

    Li, Wang

    2012-10-01

    A new finite volume method for cylindrical heat conduction problems based on local analytical solution is proposed in this paper with detailed derivation. The calculation results of this new method are compared with the traditional second-order finite volume method. The newly proposed method is more accurate than conventional ones, even though the discretized expression of this proposed method is slightly more complex than the second-order central finite volume method, making it cost more calculation time on the same grids. Numerical result shows that the total CPU time of the new method is significantly less than conventional methods for achieving the same level of accuracy. © 2012 Elsevier Ltd. All rights reserved.

  7. Study on bird's & insect's wing aerodynamics and comparison of its analytical value with standard airfoil

    Science.gov (United States)

    Ali, Md. Nesar; Alam, Mahbubul; Hossain, Md. Abed; Ahmed, Md. Imteaz

    2017-06-01

    by several species of birds. Hovering, which is generating only lift through flapping alone rather than as a product of thrust, demands a lot of energy. On the other hand, for practical knowledge we also fabricate the various bird's, insect's & fighter jet wing by using random value of parameter & test those airfoil in wind tunnel. Finally for comparison & achieving analytical knowledge we also test those airfoil model in various simulation software.

  8. The network formation assay: a spatially standardized neurite outgrowth analytical display for neurotoxicity screening.

    Science.gov (United States)

    Frimat, Jean-Philippe; Sisnaiske, Julia; Subbiah, Subanatarajan; Menne, Heike; Godoy, Patricio; Lampen, Peter; Leist, Marcel; Franzke, Joachim; Hengstler, Jan G; van Thriel, Christoph; West, Jonathan

    2010-03-21

    We present a rapid, reproducible and sensitive neurotoxicity testing platform that combines the benefits of neurite outgrowth analysis with cell patterning. This approach involves patterning neuronal cells within a hexagonal array to standardize the distance between neighbouring cellular nodes, and thereby standardize the length of the neurite interconnections. This feature coupled with defined assay coordinates provides a streamlined display for rapid and sensitive analysis. We have termed this the network formation assay (NFA). To demonstrate the assay we have used a novel cell patterning technique involving thin film poly(dimethylsiloxane) (PDMS) microcontact printing. Differentiated human SH-SY5Y neuroblastoma cells colonized the array with high efficiency, reliably producing pattern occupancies above 70%. The neuronal array surface supported neurite outgrowth, resulting in the formation of an interconnected neuronal network. Exposure to acrylamide, a neurotoxic reference compound, inhibited network formation. A dose-response curve from the NFA was used to determine a 20% network inhibition (NI(20)) value of 260 microM. This concentration was approximately 10-fold lower than the value produced by a routine cell viability assay, and demonstrates that the NFA can distinguish network formation inhibitory effects from gross cytotoxic effects. Inhibition of the mitogen-activated protein kinase (MAPK) ERK1/2 and phosphoinositide-3-kinase (PI-3K) signaling pathways also produced a dose-dependent reduction in network formation at non-cytotoxic concentrations. To further refine the assay a simulation was developed to manage the impact of pattern occupancy variations on network formation probability. Together these developments and demonstrations highlight the potential of the NFA to meet the demands of high-throughput applications in neurotoxicology and neurodevelopmental biology.

  9. Formulation and Development of a Validated UV-Spectrophotometric Analytical Method of Rutin Tablet

    Directory of Open Access Journals (Sweden)

    Murad N. Abualhasan

    2017-01-01

    Full Text Available Rutin is available in some foods, fruits, and vegetables. It has various beneficial medical effects making it useful in the treatment of various diseases. Rutin is available in different oral dosage forms such as tablets or capsules, widely available in the market. Rutin and many herbal medicines lack quality control due to unavailability of analytical methods. In this study, we formulated rutin tablet and studied its stability using a simple developed analytical method. The dissolution profile of our formulated tablet was also inspected. The results showed that our developed method was linear (R2=0.999, precise (% RSD = 0.026, and accurate (% recovery = 98.55–103.34. The formulated rutin tablet was stable under accelerated conditions as well as room temperature for 150 days (% assay > 91.69. The dissolution profile over 45 minutes of our formulated tablet showed a better dissolution (26.5% compared with the internationally marketed Rutin® tablet (18.5%. This study can serve as a guideline to companies that manufacture herbal products to improve their formulated herbs and apply validated analytical methods to check the quality of their product.

  10. Analytical design method of a device for ultrasonic elliptical vibration cutting.

    Science.gov (United States)

    Huang, Weihai; Yu, Deping; Zhang, Min; Ye, Fengfei; Yao, Jin

    2017-02-01

    Ultrasonic elliptical vibration cutting (UEVC) is effective in ultraprecision diamond cutting of hard-brittle materials and ferrous metals. However, its design is quite empirical and tedious. This paper proposes an analytical design method for developing the UEVC device which works at the Flexural-Flexural complex-mode to generate the elliptical vibration. For such UEVC device, the resonant frequencies of the two flexural vibrations are required to be the same. In addition, the nodal points of the two flexural vibrations should be coincident so that the device can be clamped without affecting the vibrations. Based on the proposed analytical design method, an UEVC device was first designed. Modal analysis of the designed UEVC device was performed by using the finite element method, which shows that the resonant frequencies coincide well with the targeted ones. Then a prototype UEVC device was fabricated, and its vibration characteristics were measured by an impedance analyzer and a laser displacement sensor. Experimental results indicate that the designed UEVC device can generate elliptical vibration with the resonant frequencies closed to the target ones. In addition, the vibration trajectory can be precisely tuned by adjusting the phase difference and the amplitude of the applied voltage. Simulation and experimental results validated the effectiveness of the analytical design method.

  11. Comparison of the calculated neutron noise using finite differences and the Analytical Nodal Method

    International Nuclear Information System (INIS)

    Larsson, Viktor; Demazière, Christophe

    2012-01-01

    Highlights: ► Numerical neutron noise calculations for a commercial PWR. ► Comparison using finite differences and the Analytical Nodal Method. ► Little gain for the higher cost of more advanced methods. ► Finite difference adequate for neutron noise calculations. - Abstract: In this paper, a comparison of the calculated neutron noise, i.e. the fluctuation of the neutron flux around its average value assuming that all processes are stationary, is conducted, where the neutron noise is calculated using finite differences alone and with finite differences where the Analytical Nodal Method is used to correct the neutron currents, respectively. It is seen that the lower the frequency of the noise source, the larger difference between the two solutions. The main conclusion from this work is that the gain of calculating the neutron noise using the more sophisticated Analytical Nodal Method compared to the increase of the corresponding computational burden is too little to motivate the use of the ANM.

  12. Characteristics, Properties and Analytical Methods of Amoxicillin: A Review with Green Approach.

    Science.gov (United States)

    de Marco, Bianca Aparecida; Natori, Jéssica Sayuri Hisano; Fanelli, Stefany; Tótoli, Eliane Gandolpho; Salgado, Hérida Regina Nunes

    2017-05-04

    Bacterial infections are the second leading cause of global mortality. Considering this fact, it is extremely important studying the antimicrobial agents. Amoxicillin is an antimicrobial agent that belongs to the class of penicillins; it has bactericidal activity and is widely used in the Brazilian health system. In literature, some analytical methods are found for the identification and quantification of this penicillin, which are essential for its quality control, which ensures maintaining the product characteristics, therapeutic efficacy and patient's safety. Thus, this study presents a brief literature review on amoxicillin and the analytical methods developed for the analysis of this drug in official and scientific papers. The major analytical methods found were high-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (U-HPLC), capillary electrophoresis and iodometry and diffuse reflectance infrared Fourier transform. It is essential to note that most of the developed methods used toxic and hazardous solvents, which makes necessary industries and researchers choose to develop environmental-friendly techniques to provide enhanced benefits to environment and staff.

  13. A Semi-Analytical Method for the PDFs of A Ship Rolling in Random Oblique Waves

    Science.gov (United States)

    Liu, Li-qin; Liu, Ya-liu; Xu, Wan-hai; Li, Yan; Tang, You-gang

    2018-03-01

    The PDFs (probability density functions) and probability of a ship rolling under the random parametric and forced excitations were studied by a semi-analytical method. The rolling motion equation of the ship in random oblique waves was established. The righting arm obtained by the numerical simulation was approximately fitted by an analytical function. The irregular waves were decomposed into two Gauss stationary random processes, and the CARMA (2, 1) model was used to fit the spectral density function of parametric and forced excitations. The stochastic energy envelope averaging method was used to solve the PDFs and the probability. The validity of the semi-analytical method was verified by the Monte Carlo method. The C11 ship was taken as an example, and the influences of the system parameters on the PDFs and probability were analyzed. The results show that the probability of ship rolling is affected by the characteristic wave height, wave length, and the heading angle. In order to provide proper advice for the ship's manoeuvring, the parametric excitations should be considered appropriately when the ship navigates in the oblique seas.

  14. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard test method for macroetching metals and alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test procedures describe the methods of macro- etching metals and alloys to reveal their macrostructure. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.2, 7.1, 8.1.3, 8.2.1, 8.8.3, 8.10.1.1, and 8.13.2.

  16. Optimization of instrumental neutron activation analysis method by means of 2k experimental design technique aiming the validation of analytical procedures

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2013-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2 k experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  17. Characterization of Compton-scatter imaging with an analytical simulation method

    Science.gov (United States)

    Jones, Kevin C.; Redler, Gage; Templeton, Alistair; Bernard, Damian; Turian, Julius V.; Chu, James C. H.

    2018-01-01

    By collimating the photons scattered when a megavoltage therapy beam interacts with the patient, a Compton-scatter image may be formed without the delivery of an extra dose. To characterize and assess the potential of the technique, an analytical model for simulating scatter images was developed and validated against Monte Carlo (MC). For three phantoms, the scatter images collected during irradiation with a 6 MV flattening-filter-free therapy beam were simulated. Images, profiles, and spectra were compared for different phantoms and different irradiation angles. The proposed analytical method simulates accurate scatter images up to 1000 times faster than MC. Minor differences between MC and analytical simulated images are attributed to limitations in the isotropic superposition/convolution algorithm used to analytically model multiple-order scattering. For a detector placed at 90° relative to the treatment beam, the simulated scattered photon energy spectrum peaks at 140-220 keV, and 40-50% of the photons are the result of multiple scattering. The high energy photons originate at the beam entrance. Increasing the angle between source and detector increases the average energy of the collected photons and decreases the relative contribution of multiple scattered photons. Multiple scattered photons cause blurring in the image. For an ideal 5 mm diameter pinhole collimator placed 18.5 cm from the isocenter, 10 cGy of deposited dose (2 Hz imaging rate for 1200 MU min-1 treatment delivery) is expected to generate an average 1000 photons per mm2 at the detector. For the considered lung tumor CT phantom, the contrast is high enough to clearly identify the lung tumor in the scatter image. Increasing the treatment beam size perpendicular to the detector plane decreases the contrast, although the scatter subject contrast is expected to be greater than the megavoltage transmission image contrast. With the analytical method, real-time tumor tracking may be possible

  18. Analytical standards for the measurement of nutrients in infant formula : macronutrients, minerals, carnitine, taurine and nucleotides

    NARCIS (Netherlands)

    Capuano, E.; Alewijn, M.; Ruth, van S.M.; Verkaik-Kloosterman, J.

    2012-01-01

    Adequate methods with known performance characteristics for the assessment of the concentration of nutrients in infant and follow-on formula (referred to as "formula") are essential in the evaluation whether the composition deviates from the compositional provisions as laid down by law. Many

  19. Analytical methods for determination of terbinafine hydrochloride in pharmaceuticals and biological materials

    Directory of Open Access Journals (Sweden)

    Basavaiah Kanakapura

    2016-06-01

    Full Text Available Terbinafine is a new powerful antifungal agent indicated for both oral and topical treatment of mycosessince. It is highly effective in the treatment of determatomycoses. The chemical and pharmaceutical analysis of the drug requires effective analytical methods for quality control and pharmacodynamic and pharmacokinetic studies. Ever since it was introduced as an effective antifungal agent, many methods have been developed and validated for its assay in pharmaceuticals and biological materials. This article reviews the various methods reported during the last 25 years.

  20. Approximate analytical solution of diffusion equation with fractional time derivative using optimal homotopy analysis method

    Directory of Open Access Journals (Sweden)

    S. Das

    2013-12-01

    Full Text Available In this article, optimal homotopy-analysis method is used to obtain approximate analytic solution of the time-fractional diffusion equation with a given initial condition. The fractional derivatives are considered in the Caputo sense. Unlike usual Homotopy analysis method, this method contains at the most three convergence control parameters which describe the faster convergence of the solution. Effects of parameters on the convergence of the approximate series solution by minimizing the averaged residual error with the proper choices of parameters are calculated numerically and presented through graphs and tables for different particular cases.

  1. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  2. Analytical Methods for the Determination of Rosuvastatin in Pharmaceutical Formulations and Biological Fluids: A Critical Review.

    Science.gov (United States)

    Ângelo, Marilene Lopes; Moreira, Fernanda de Lima; Morais Ruela, André Luís; Santos, Ana Laura Araújo; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2018-07-04

    Rosuvastatin calcium (ROS), ( Figure 1 ) belongs to the "statins" group, which is the 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor. This drug is indicated for dyslipidemias treatment and can help to decrease the level of "bad cholesterol" and can consequently reduce the development of atherosclerosis and the risk of heart diseases. ROS was developed by Astra-Zeneca and it was approved in 2003 by the FDA in the United States. In 2015, under the trade name Crestor®, it was the fourth largest selling drug in the United States with sales above $5 billion. This study presents a literature review of analytical methods for the quantification of ROS in pharmaceutical preparations and biological fluids. The major analytical methods described in this study for ROS were spectrophotometry, high-performance liquid chromatography (HPLC) coupled to ultraviolet (UV) detection, and tandem mass spectrometry (LC-MS/MS).

  3. Environmental equity research: review with focus on outdoor air pollution research methods and analytic tools.

    Science.gov (United States)

    Miao, Qun; Chen, Dongmei; Buzzelli, Michael; Aronson, Kristan J

    2015-01-01

    The objective of this study was to review environmental equity research on outdoor air pollution and, specifically, methods and tools used in research, published in English, with the aim of recommending the best methods and analytic tools. English language publications from 2000 to 2012 were identified in Google Scholar, Ovid MEDLINE, and PubMed. Research methodologies and results were reviewed and potential deficiencies and knowledge gaps identified. The publications show that exposure to outdoor air pollution differs by social factors, but findings are inconsistent in Canada. In terms of study designs, most were small and ecological and therefore prone to the ecological fallacy. Newer tools such as geographic information systems, modeling, and biomarkers offer improved precision in exposure measurement. Higher-quality research using large, individual-based samples and more precise analytic tools are needed to provide better evidence for policy-making to reduce environmental inequities.

  4. Application of nuclear analytical methods to heavy metal pollution studies of estuaries

    International Nuclear Information System (INIS)

    Anders, B.; Junge, W.; Knoth, J.; Michaelis, W.; Pepelnik, R.; Schwenke, H.

    1984-01-01

    Important objectives of heavy metal pollution studies of estuaries are the understanding of the transport phenomena in these complex ecosystems and the discovery of the pollution history and the geochemical background. Such studies require high precision and accuracy of the analytical methods. Moreover, pronounced spatial heterogeneities and temporal variabilities that are typical for estuaries necessitate the analysis of a great number of samples if relevant results are to be obtained. Both requirements can economically be fulfilled by a proper combination of analytical methods. Applications of energy-dispersive X-ray fluorescence analysis with total reflection of the exciting beam at the sample support and of neutron activation analysis with both thermal and fast neutrons are reported in the light of pollution studies performed in the Lower Elbe River. (orig.)

  5. Abstracts book of 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements

    International Nuclear Information System (INIS)

    1995-01-01

    The 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements has been held in Poznan 27-28 April 1995. The new versions of analytical methods have been presented for quantitative determination of trace elements in biological, environmental and geological materials. Also the number of special techniques for sample preparation enables achievement the best precision of analytical results have been shown and discussed

  6. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  7. Developing automated analytical methods for scientific environments using LabVIEW.

    Science.gov (United States)

    Wagner, Christoph; Armenta, Sergio; Lendl, Bernhard

    2010-01-15

    The development of new analytical techniques often requires the building of specially designed devices, each requiring its own dedicated control software. Especially in the research and development phase, LabVIEW has proven to be one highly useful tool for developing this software. Yet, it is still common practice to develop individual solutions for different instruments. In contrast to this, we present here a single LabVIEW-based program that can be directly applied to various analytical tasks without having to change the program code. Driven by a set of simple script commands, it can control a whole range of instruments, from valves and pumps to full-scale spectrometers. Fluid sample (pre-)treatment and separation procedures can thus be flexibly coupled to a wide range of analytical detection methods. Here, the capabilities of the program have been demonstrated by using it for the control of both a sequential injection analysis - capillary electrophoresis (SIA-CE) system with UV detection, and an analytical setup for studying the inhibition of enzymatic reactions using a SIA system with FTIR detection.

  8. Analytical Method of Malculation of the Current and Torque a Reluctance Stepper Motor via Fourier Series

    Directory of Open Access Journals (Sweden)

    Pavel Zaskalicky

    2008-01-01

    Full Text Available Reluctance stepper motors are becoming to be very attractive transducer to conversion of electric signal to the mechanical position. Due to its simple construction is reluctance machine considered a very reliable machine which not requiring any maintenance. Present paper proposes a mathematical method of an analytical calculus of a phase current and electromagnetic torque of the motor via Fourier series. Saturation effect and winding reluctance are neglected.

  9. Analytical Treatment of Higher-Order Graphs: A Path Ordinal Method for Solving Graphs

    Directory of Open Access Journals (Sweden)

    Hala Kamal

    2017-11-01

    Full Text Available Analytical treatment of the composition of higher-order graphs representing linear relations between variables is developed. A path formalism to deal with problems in graph theory is introduced. It is shown how paths in the composed graph representing individual contributions to variables relation can be enumerated and represented by ordinals. The method allows for one to extract partial information and gives an alternative to classical graph approach.

  10. Validation of the analytical method for sodium dichloroisocyanurate aimed at drinking water disinfection

    International Nuclear Information System (INIS)

    Martinez Alvarez, Luis Octavio; Alejo Cisneros, Pedro; Garcia Pereira, Reynaldo; Campos Valdez, Doraily

    2014-01-01

    Cuba has developed the first effervescent 3.5 mg sodium dichloroisocyanurate tablets as a non-therapeutic active principle. This ingredient releases certain amount of chlorine when dissolved into a litre of water and it can cause adequate disinfection of drinking water ready to be taken after 30 min. Developing and validating an analytical iodometric method applicable to the quality control of effervescent 3.5 mg sodium dichloroisocyanurate tablets

  11. CO2 Leakage, Storage and Injection Monitoring by Using Experimental, Numerical and Analytical Methods

    Directory of Open Access Journals (Sweden)

    A. Namdar

    2014-09-01

    Full Text Available The maintaining environment is priority to any plan in human life. It is planned for monitoring CO2 injection, storage and leakage by using geophysical, numerical and analytical methods in seismic zone. In this regard the mineralogy, chemical composite, lithology, seismic wave propagation, small earthquake, accelerating natural earthquake, thermal stress-strain modeling, ground movement level and fault activation will be consider. It is expected to better understand CO2 leakage, storage and injection process and problems.

  12. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  13. Analytical Method Used to Calculate Pile Foundations with the Widening Up on a Horizontal Static Impact

    Science.gov (United States)

    Kupchikova, N. V.; Kurbatskiy, E. N.

    2017-11-01

    This paper presents a methodology for the analytical research solutions for the work pile foundations with surface broadening and inclined side faces in the ground array, based on the properties of Fourier transform of finite functions. The comparative analysis of the calculation results using the suggested method for prismatic piles, piles with surface broadening prismatic with precast piles and end walls with precast wedges on the surface is described.

  14. An analytical method for determining the temperature dependent moisture diffusivities of pumpkin seeds during drying process

    Energy Technology Data Exchange (ETDEWEB)

    Can, Ahmet [Department of Mechanical Engineering, University of Trakya, 22030 Edirne (Turkey)

    2007-02-15

    This paper presents an analytical method, which determines the moisture diffusion coefficients for the natural and forced convection hot air drying of pumpkin seeds and their temperature dependence. In order to obtain scientific data, the pumpkin seed drying process was investigated under both natural and forced hot air convection regimes. This paper presents the experimental results in which the drying air was heated by solar energy. (author)

  15. DEVELOPMENT OF ANALYTICAL METHODS IN METABOLOMICS FOR THE STUDY OF HEREDITARY AND ACQUIRED GENETIC DISEASE

    OpenAIRE

    Arvonio, Raffaele

    2011-01-01

    METABOLOMICS AND MASS SPECTROMETRY The research project take place in the branch of metabolomics, which involves the systematic study of the metabolites present in a cell and in this area MS, thanks to its potential to carry out controlled experiments of fragmentation, plays a role as a key methodology for identification of various metabolites. The work of thesis project is focused on the analytical methods development for the diagnosis of metabolic diseases and is divided as follows: ...

  16. A field study of selected U.S. Geological Survey analytical methods for measuring pesticides in filtered stream water, June - September 2012

    Science.gov (United States)

    Martin, Jeffrey D.; Norman, Julia E.; Sandstrom, Mark W.; Rose, Claire E.

    2017-09-06

    -use settings, as well as sites on major rivers.The results of the field study identified several challenges for the analysis and interpretation of data analyzed by both old and new methods, particularly when data span the change in methods and are combined for analysis of temporal trends in water quality. The main challenges identified are large (greater than 30 percent), statistically significant differences in analytical recovery, detection capability, and (or) measured concentrations for selected pesticides. These challenges are documented and discussed, but specific guidance or statistical methods to resolve these differences in methods are beyond the scope of the report. The results of the field study indicate that the implications of the change in analytical methods must be assessed individually for each pesticide and method.Understanding the possible causes of the systematic differences in concentrations between methods that remain after recovery adjustment might be necessary to determine how to account for the differences in data analysis. Because recoveries for each method are independently determined from separate reference standards and spiking solutions, the differences might be due to an error in one of the reference standards or solutions or some other basic aspect of standard procedure in the analytical process. Further investigation of the possible causes is needed, which will lead to specific decisions on how to compensate for these differences in concentrations in data analysis. In the event that further investigations do not provide insight into the causes of systematic differences in concentrations between methods, the authors recommend continuing to collect and analyze paired environmental water samples by both old and new methods. This effort should be targeted to seasons, sites, and expected concentrations to supplement those concentrations already assessed and to compare the ongoing analytical recovery of old and new methods to those observed in the

  17. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  18. Analytic Methods for Evaluating Patterns of Multiple Congenital Anomalies in Birth Defect Registries.

    Science.gov (United States)

    Agopian, A J; Evans, Jane A; Lupo, Philip J

    2018-01-15

    It is estimated that 20 to 30% of infants with birth defects have two or more birth defects. Among these infants with multiple congenital anomalies (MCA), co-occurring anomalies may represent either chance (i.e., unrelated etiologies) or pathogenically associated patterns of anomalies. While some MCA patterns have been recognized and described (e.g., known syndromes), others have not been identified or characterized. Elucidating these patterns may result in a better understanding of the etiologies of these MCAs. This article reviews the literature with regard to analytic methods that have been used to evaluate patterns of MCAs, in particular those using birth defect registry data. A popular method for MCA assessment involves a comparison of the observed to expected ratio for a given combination of MCAs, or one of several modified versions of this comparison. Other methods include use of numerical taxonomy or other clustering techniques, multiple regression analysis, and log-linear analysis. Advantages and disadvantages of these approaches, as well as specific applications, were outlined. Despite the availability of multiple analytic approaches, relatively few MCA combinations have been assessed. The availability of large birth defects registries and computing resources that allow for automated, big data strategies for prioritizing MCA patterns may provide for new avenues for better understanding co-occurrence of birth defects. Thus, the selection of an analytic approach may depend on several considerations. Birth Defects Research 110:5-11, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. An Analytical Model for CMUTs with Square Multilayer Membranes Using the Ritz Method

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    2016-03-01

    Full Text Available Capacitive micromachined ultrasonic transducer (CMUT multilayer membrane plays an important role in the performance metrics including the transmitting efficiency and the receiving sensitivity. However, there are few studies of the multilayer membranes. Some analytical models simplify the multilayer membrane as monolayer, which results in inaccuracies. This paper presents a new analytical model for CMUTs with multilayer membranes, which can rapidly and accurately predict static deflection and response frequency of the multilayer membrane under external pressures. The derivation is based on the Ritz method and Hamilton’s principle. The mathematical relationships between the external pressure, static deflection, and response frequency are obtained. Relevant residual stress compensation method is derived. The model has been verified for three-layer and double-layer CMUT membranes by comparing its results with finite element method (FEM simulations, experimental data, and other monolayer models that treat CMUTs as monolayer plates/membranes. For three-layer CMUT membranes, the relative errors are ranging from 0.71%–3.51% for the static deflection profiles, and 0.35%–4.96% for the response frequencies, respectively. For the double-layer CMUT membrane, the relative error with residual stress compensation is 4.14% for the central deflection, and −1.17% for the response frequencies, respectively. This proposed analytical model can serve as a reliable reference and an accurate tool for CMUT design and optimization.

  20. Simulation of an Electromagnetic Acoustic Transducer Array by Using Analytical Method and FDTD

    Directory of Open Access Journals (Sweden)

    Yuedong Xie

    2016-01-01

    Full Text Available Previously, we developed a method based on FEM and FDTD for the study of an Electromagnetic Acoustic Transducer Array (EMAT. This paper presents a new analytical solution to the eddy current problem for the meander coil used in an EMAT, which is adapted from the classic Deeds and Dodd solution originally intended for circular coils. The analytical solution resulting from this novel adaptation exploits the large radius extrapolation and shows several advantages over the finite element method (FEM, especially in the higher frequency regime. The calculated Lorentz force density from the analytical EM solver is then coupled to the ultrasonic simulations, which exploit the finite-difference time-domain (FDTD method to describe the propagation of ultrasound waves, in particular for Rayleigh waves. Radiation pattern obtained with Hilbert transform on time-domain waveforms is proposed to characterise the sensor in terms of its beam directivity and field distribution along the steering angle, which can produce performance parameters for an EMAT array, facilitating the optimum design of such sensors.

  1. A first course in ordinary differential equations analytical and numerical methods

    CERN Document Server

    Hermann, Martin

    2014-01-01

    This book presents a modern introduction to analytical and numerical techniques for solving ordinary differential equations (ODEs). Contrary to the traditional format—the theorem-and-proof format—the book is focusing on analytical and numerical methods. The book supplies a variety of problems and examples, ranging from the elementary to the advanced level, to introduce and study the mathematics of ODEs. The analytical part of the book deals with solution techniques for scalar first-order and second-order linear ODEs, and systems of linear ODEs—with a special focus on the Laplace transform, operator techniques and power series solutions. In the numerical part, theoretical and practical aspects of Runge-Kutta methods for solving initial-value problems and shooting methods for linear two-point boundary-value problems are considered. The book is intended as a primary text for courses on the theory of ODEs and numerical treatment of ODEs for advanced undergraduate and early graduate students. It is assumed t...

  2. A novel analytical approximation technique for highly nonlinear oscillators based on the energy balance method

    Directory of Open Access Journals (Sweden)

    Md. Alal Hosen

    2016-01-01

    Full Text Available In the present paper, a novel analytical approximation technique has been proposed based on the energy balance method (EBM to obtain approximate periodic solutions for the focus generalized highly nonlinear oscillators. The expressions of the natural frequency-amplitude relationship are obtained using a novel analytical way. The accuracy of the proposed method is investigated on three benchmark oscillatory problems, namely, the simple relativistic oscillator, the stretched elastic wire oscillator (with a mass attached to its midpoint and the Duffing-relativistic oscillator. For an initial oscillation amplitude A0 = 100, the maximal relative errors of natural frequency found in three oscillators are 2.1637%, 0.0001% and 1.201%, respectively, which are much lower than the errors found using the existing methods. It is highly remarkable that an excellent accuracy of the approximate natural frequency has been found which is valid for the whole range of large values of oscillation amplitude as compared with the exact ones. Very simple solution procedure and high accuracy that is found in three benchmark problems reveal the novelty, reliability and wider applicability of the proposed analytical approximation technique.

  3. Medical ethical standards in dermatology: an analytical study of knowledge, attitudes and practices.

    Science.gov (United States)

    Mostafa, W Z; Abdel Hay, R M; El Lawindi, M I

    2015-01-01

    Dermatology practice has not been ethically justified at all times. The objective of the study was to find out dermatologists' knowledge about medical ethics, their attitudes towards regulatory measures and their practices, and to study the different factors influencing the knowledge, the attitude and the practices of dermatologists. This is a cross-sectional comparative study conducted among 214 dermatologists, from five Academic Universities and from participants in two conferences. A 54 items structured anonymous questionnaire was designed to describe the demographical characteristics of the study group as well as their knowledge, attitude and practices regarding the medical ethics standards in clinical and research settings. Five scoring indices were estimated regarding knowledge, attitude and practice. Inferential statistics were used to test differences between groups as indicated. The Student's t-test and analysis of variance were carried out for quantitative variables. The chi-squared test was conducted for qualitative variables. The results were considered statistically significant at a P > 0.05. Analysis of the possible factors having impact on the overall scores revealed that the highest knowledge scores were among dermatologists who practice in an academic setting plus an additional place; however, this difference was statistically non-significant (P = 0.060). Female dermatologists showed a higher attitude score compared to males (P = 0.028). The highest significant attitude score (P = 0.019) regarding clinical practice was recorded among those practicing cosmetic dermatology. The different studied groups of dermatologists revealed a significant impact on the attitude score (P = 0.049), and the evidence-practice score (P dermatology research. © 2014 European Academy of Dermatology and Venereology.

  4. Quantitative data standardization of X-ray based densitometry methods

    Science.gov (United States)

    Sergunova, K. A.; Petraikin, A. V.; Petrjajkin, F. A.; Akhmad, K. S.; Semenov, D. S.; Potrakhov, N. N.

    2018-02-01

    In the present work is proposed the design of special liquid phantom for assessing the accuracy of quantitative densitometric data. Also are represented the dependencies between the measured bone mineral density values and the given values for different X-ray based densitometry techniques. Shown linear graphs make it possible to introduce correction factors to increase the accuracy of BMD measurement by QCT, DXA and DECT methods, and to use them for standardization and comparison of measurements.

  5. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  6. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  7. FLOW-INJECTION CALIBRATION OF INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING THE GENERALIZED STANDARD ADDITIONS METHOD

    OpenAIRE

    GINE, MF; KRUG, FJ; FILHO, HB; DOSREIS, BF; ZAGATTO, EAG; BRUNS, RE

    1988-01-01

    The generalised standard additions method (GSAM), employing least-squares regression, provides a convenient method for obtaining the calibration matrix (K-matrix) in multi-element analysis. The GSAM is based on the response variations obtained after the addition of known incremental amounts of the interfering and test elements to the samples. As application of the GSAM requires a number of additions, automation is recommended for routine analytical work. Any automated procedure for implementi...

  8. Effect of variable lorentz forces on nanofluid flow in movable parallel plates utilizing analytical method

    Directory of Open Access Journals (Sweden)

    Kh. Hosseinzadeh

    2017-09-01

    Full Text Available The present paper focuses on the examination of the effect of Brownian motion and thermophoresis phenomenon and Lewis number on MHD nanofluid flow along with the heat transfer between two parallel plates. Utilizing a suitable transformation for the velocity, temperature and concentration, the basic governing equations of the flow, heat and mass transfer were reduced to a set of ordinary differential equations. After the governing equation is derived; various analytical methods such as Homotopy Perturbation Method (HPM, Collocation Method (CM and Finite Element Method (FEM are applied to deal with the problem. The obtained Results revealed that Collocation Method (CM has an excellent agreement with Finite Element numerical method, so it can be a proper analytical method for solving the problem. Then the influence of the following parameters is investigated: Brownian motion parameter (Nb, thermophoresis parameter (Nt, Squeeze number (S, Hartmann number (M and Lewis number (Le on non-dimensional temperature, velocity and nanoparticle concentration. The results indicated that increasing the Brownian motion parameter would cause an increase in temperature profile while the effect of increasing Brownian motion on concentration profile is vice versa, moreover, by increasing the Thermophoresis parameter we would have a decreases in temperature profile and an increase in concentration profile.

  9. Analytical and numerical methods for computing electron partial intensities in the case of multilayer systems

    International Nuclear Information System (INIS)

    Afanas’ev, Victor P.; Efremenko, Dmitry S.; Kaplya, Pavel S.

    2016-01-01

    Highlights: • The OKG-model is extended to finite thickness layers. • An efficient matrix technique for computing partial intensities is proposed. • Good agreement is obtained for computed partial intensities and experimental data. - Abstract: We present two novel methods for computing energy spectra and angular distributions of electrons emitted from multi-layer solids. They are based on the Ambartsumian–Chandrasekhar (AC) equations obtained by using the invariant imbedding method. The first method is analytical and relies on a linearization of AC equations and the use of the small-angle approximation. The corresponding solution is in good agreement with that computed by using the Oswald–Kasper–Gaukler (OKG) model, which is extended to the case of layers of finite thickness. The second method is based on the discrete ordinate formalism and relies on a transformation of the AC equations to the algebraic Ricatti and Lyapunov equations, which are solved by using the backward differential formula. Unlike the previous approach, this method can handle both linear and nonlinear equations. We analyze the applicability of the proposed methods to practical problems of computing REELS spectra. To demonstrate the efficiency of the proposed methods, several computational examples are considered. Obtained numerical and analytical solutions show good agreement with the experimental data and Monte-Carlo simulations. In addition, the impact of nonlinear terms in the Ambartsumian–Chandrasekhar equations is analyzed.

  10. Comparison of Standard and Fast Charging Methods for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Petr Chlebis

    2014-01-01

    Full Text Available This paper describes a comparison of standard and fast charging methods used in the field of electric vehicles and also comparison of their efficiency in terms of electrical energy consumption. The comparison was performed on three-phase buck converter, which was designed for EV’s fast charging station. The results were obtained by both mathematical and simulation methods. The laboratory model of entire physical application, which will be further used for simulation results verification, is being built in these days.

  11. Study on method of data standardization in interferometric testing

    Science.gov (United States)

    Chen, Wei

    2010-10-01

    As a rule, Interferometers are used to test the figure in the polishing phase of optical component, it could provide advance tutor suggestion for manufacturing. It is unable to get the whole wave-front interferogram usually because phase-shift Interferometry is sensitive to environment vibration, so the exactly interference data of the optical surface could not be obtained. Various spatial point on the tested optical component will be given by calculation method about arithmetic average value of equal accuracy is provied. This paper describes the testing results of optical components in size Φ1200mm, it is proved the method could eliminate the vibration effectively and get the standardization data.

  12. Cutibacterium acnes molecular typing: time to standardize the method.

    Science.gov (United States)

    Dagnelie, M-A; Khammari, A; Dréno, B; Corvec, S

    2018-03-12

    The Gram-positive, anaerobic-aerotolerant bacterium Cutibacterium acnes is a commensal of human healthy skin, subdivided into six main phylogenetic groups or phylotypes: IA1, IA2, IB, IC, II and III. To decipher how far C. acnes specific subgroups are involved in disease physiopathology, different molecular typing methods have been developed to identify these subgroups (i.e. phylotypes, clonal complexes, SLST-types). However, as there were several molecular typing methods developed over the last decade, comparing the results from one article to another became a difficult task. Based on the scientific literature, the aim of this narrative review is to propose a standardized method to perform C. acnes molecular typing, according to the degree of resolution needed (phylotypes, clonal complexes, or SLST-types). We discuss the different typing methods existing with a critical point of view, raising the advantages/drawbacks, and identify the most frequently used. Consequently, we propose a consensus algorithm according to the needed phylogeny resolution level. We first propose to use multiplex PCR for phylotype identification, MLST9 for clonal complex determination, and SLST for phylogeny investigation including numerous isolates. There is an obvious need to create a consensus about C. acnes molecular typing methods. This standardization will facilitate the comparison of the results from one article to another, and also the interpretations of clinical data. Copyright © 2018. Published by Elsevier Ltd.

  13. Analytical methods for fissionable material determinations in the nuclear fuel cycle. Progress report, October 1, 1978-September 30, 1979

    International Nuclear Information System (INIS)

    Waterbury, G.R.

    1980-03-01

    Work continues on the development of dissolution techniques for difficult-to-dissolve nuclear materials, the development of methods and automated instruments for plutonium, uranium, and thorium determinations, and the preparation of plutonium materials for the Safeguards Analytical Laboratory Evaluation (SALE) program and distribution by the National Bureau of Standards (NBS) as standard reference materials (SRMs). We are measuring the loner plutonium isotope half-lives, evaluating the isotope correlation techniques and the chemistry involved in the mass-spectrometric ion-bead techniques, and analyzing the SALE uranium materials. Completed subtasks include evaluations of various Teflon materials to recommend those acceptable for the dissolution apparatus developed at LASL, investigations of laser-enhanced dissolution of refractory materials, determinations of diverse ion effects on the microgram-sensitive method for determining uranium, fabrication of the first automated controlled-potential coulometric analyzer for determining plutonium, preparation of a 244 Pu material for distribution by NBS as a SRM, and determination of the half-life of 239 Pu. Work has been started on a spectrophotometric method for determining microgram quantities of plutonium, a microcomplexometric titration method for determining uranium, the use of new reagents for separations of plutonium, the preparation and packaging of a new lot of high-purity plutonium metal for distribution by NBS as a plutonium chemical SRM, and determination of half-lives of other plutonium isotopes

  14. Analytical Method and Semianalytical Method for Analysis of Scattering by Anisotropic Sphere: A Review

    Directory of Open Access Journals (Sweden)

    Chao Wan

    2012-01-01

    Full Text Available The history of methods for the electromagnetic scattering by an anisotropic sphere has been reviewed. Two main methods, angular expansion method and T-matrix method, which are widely used for the anisotropic sphere, are expressed in Cartesian coordinate firstly. The comparison of those and the further exploration on the scattering field are illustrated afterwards. Based on the most general form concluded by variable separation method, the coupled electric field and magnetic field of radial anisotropic sphere can be derived. By simplifying the condition, simpler case of uniaxial anisotropic media is expressed with confirmed coefficients for the internal and external field. Details of significant phenomenon are presented.

  15. Comparison of soil sampling and analytical methods for asbestos at the Sumas Mountain Asbestos Site-Working towards a toolbox for better assessment.

    Directory of Open Access Journals (Sweden)

    Julie Wroble

    Full Text Available Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA's Office of Land and Emergency Management (OLEM currently recommends the rigorous process of Activity Based Sampling (ABS to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab" samples and incremental sampling methodology (ISM. Analyses were conducted using polarized light microscopy (PLM, transmission electron microscopy (TEM methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.

  16. An endogenous standard, radioisotopic ratio method in NAA

    International Nuclear Information System (INIS)

    Byrne, A.R.; Dermelj, M.

    1997-01-01

    A derivative form of NAA is proposed which is based on the use of an endogenous internal standard of already known concentration in the sample. If a comparator with a known ratio of the determinand and endogenous standard are co-irradiated with the sample, the determinand concentration is derived in terms of the endogenous standard concentration and the activity ratios of the two induced nuclides in the sample and comparator. As well as eliminating the sample mass and greatly reducing errors caused by pulse pile-up and geometrical differences, it was shown that in the radiochemical mode, if the endogenous standard is chosen so that the induced activity is radioisotopic with that from the determinand, the radiochemical yield is also eliminated and the risk non-achievement of isotopic exchange greatly reduced. The method is demonstrated with good results on reference materials for the determination of I, Mn and Ni. The advantages and disadvantages of this approach are discussed. It is suggested that it may be of application in quality control and in extending the range of certified elements in reference materials. (author)

  17. An Analytical Method to Determine the Response of a Micro Capacitive Pressure Sensor

    Directory of Open Access Journals (Sweden)

    Ashwin Simha

    2011-07-01

    Full Text Available The response of a capacitive pressure sensor is generally represented by a fourth order partial differential equation which is complex to solve and does not possess an exact solution. Several attempts have been made earlier through various techniques such as the Galerkin method, Finite Difference Method etc. In this paper an attempt has been made to develop a simple approximate analytical approach to determine the response of a capacitive pressure sensor whose diaphragm is designed to undergo very small deflections (typically less than 25 % of the thickness. The non-uniform gap between the electrodes is mathematically expressed as a combination of the initial gap between the electrodes (in the undeformed state and a displacement function in (x, y. The proposed displacement function is then utilized in evaluating the capacitance as a function of the applied pressure. The results obtained from the analytical approach are benchmarked against those obtained from COMSOL Multiphysics®, a popular Finite Element Analysis tool in the MEMS industry. It is observed that the results obtained from COMSOL Multiphysics® and those from the analytical approach are in good agreement with a maximum deviation of about 3.38 %.

  18. Finite-analytic numerical method for unsteady two-dimensional Navier-Stokes equations

    Science.gov (United States)

    Chen, C.-J.; Chen, H.-C.

    1984-01-01

    A finite analytic (FA) numerical solution is developed for unsteady two-dimensional Navier-Stokes equations. The FA method utilizes the analytic solution in a small local element to formulate the algebraic representation of partial differential equations. The combination of linear and exponential functions that satisfy the governing equation is adopted as the boundary function, thereby improving the accuracy of the finite analytic solution. Two flows, one a starting cavity flow and the other a vortex shedding flow behind a rectangular block, are solved by the FA method. The starting square cavity flow is solved for Reynolds number of 400, 1000, and 2000 to show the accuracy and stability of the FA solution. The FA solution for flow over a rectangular block (H x H/4) predicts the Strouhal number for Reynolds numbers of 100 and 500 to be 0.156 and 0.125. Details of the flow patterns are given. In addition to streamlines and vorticity distribution, rest-streamlines are given to illustrate the vortex motion downstream of the block.

  19. Analytical derivatives of the individual state energies in ensemble density functional theory method. I. General formalism.

    Science.gov (United States)

    Filatov, Michael; Liu, Fang; Martínez, Todd J

    2017-07-21

    The state-averaged (SA) spin restricted ensemble referenced Kohn-Sham (REKS) method and its state interaction (SI) extension, SI-SA-REKS, enable one to describe correctly the shape of the ground and excited potential energy surfaces of molecules undergoing bond breaking/bond formation reactions including features such as conical intersections crucial for theoretical modeling of non-adiabatic reactions. Until recently, application of the SA-REKS and SI-SA-REKS methods to modeling the dynamics of such reactions was obstructed due to the lack of the analytical energy derivatives. In this work, the analytical derivatives of the individual SA-REKS and SI-SA-REKS energies are derived. The final analytic gradient expressions are formulated entirely in terms of traces of matrix products and are presented in the form convenient for implementation in the traditional quantum chemical codes employing basis set expansions of the molecular orbitals. The implementation and benchmarking of the derived formalism will be described in a subsequent article of this series.

  20. An analytic method for S-expansion involving resonance and reduction

    Energy Technology Data Exchange (ETDEWEB)

    Ipinza, M.C.; Penafiel, D.M. [Departamento de Fisica, Universidad de Concepcion (Chile); DISAT, Politecnico di Torino (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Torino (Italy); Lingua, F. [DISAT, Politecnico di Torino (Italy); Ravera, L. [DISAT, Politecnico di Torino (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Torino (Italy)

    2016-11-15

    In this paper we describe an analytic method able to give the multiplication table(s) of the set(s) involved in an S-expansion process (with either resonance or 0{sub S}-resonant-reduction) for reaching a target Lie (super)algebra from a starting one, after having properly chosen the partitions over subspaces of the considered (super)algebras. This analytic method gives us a simple set of expressions to find the subset decomposition of the set(s) involved in the process. Then, we use the information coming from both the initial (super)algebra and the target one for reaching the multiplication table(s) of the mentioned set(s). Finally, we check associativity with an auxiliary computational algorithm, in order to understand whether the obtained set(s) can describe semigroup(s) or just abelian set(s) connecting two (super)algebras. We also give some interesting examples of application, which check and corroborate our analytic procedure and also generalize some result already presented in the literature. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. The Methodical Instrumentarium for Analytical Monitoring of Markets for High-Tech Products

    Directory of Open Access Journals (Sweden)

    Mikaelian Suren G.

    2017-10-01

    Full Text Available The article is aimed at clarifying the essential characteristics of high-tech products and specifying the features of analytical monitoring of markets for high-tech products. The conceptual approaches to interpretation of the essence of high-tech products as a basic concept in the categorical apparatus for researching the systemic and complex processes of technological development have been clarified. The most efficient instruments for assessing innovation processes in the high-tech sphere have been systematized. The methodical instrumentarium for analytical monitoring of the markets for high-tech products has been clarified. The terminology of a high-tech product has been clarified in order to formulate the methodical instrumentarium for analytical monitoring of market for high-tech products. It has been determined that «high-tech products» are the original basic concept in the categorical apparatus for researching the systemic and complex processes of the high-tech market that needs to be concretized. Conceptual approaches to the essence of high-tech products have been systematized.

  2. Origins, Phytochemistry, Pharmacology, Analytical Methods and Safety of Cortex Moutan (Paeonia suffruticosa Andrew): A Systematic Review.

    Science.gov (United States)

    Wang, Zhiqiang; He, Chunnian; Peng, Yong; Chen, Feihu; Xiao, Peigen

    2017-06-07

    Cortex Moutan (CM), a well-known traditional Chinese medicine, is commonly used for treating various diseases in China and other eastern Asian countries. Recorded in Pharmacopeias of several countries, CM is now drawing increasing attention and under extensive studies in various fields. Phytochemical studies indicate that CM contains many valuable secondary metabolites, such as monoterpene glycosides and phenols. Ample evidence from pharmacological researches suggest that CM has a wide spectrum of activities, such as anti-inflammatory, anti-oxidant, anti-tumor, anti-diabetic, cardiovascular protective, neuroprotective, hepatoprotective effects. Moreover, various analytical methods were established for the quality evaluation and safety control of CM. This review synopsizes updated information concerning the origins, phytochemistry, pharmacology, analytical method and safety of CM, aiming to provide favorable references for modern CM research and application. In conclusion, continuing pharmacological investigations concerning CM should be conducted to unravel its pharmacological mechanisms. Further researches are necessary to obtain comprehensive and applicable analytical approach for quality evaluation and establish harmonized criteria of CM.

  3. An analytical method for the investigation of instability of a collisionless plasma in strong magnetic fields

    International Nuclear Information System (INIS)

    Zakharov, V.U.

    1993-01-01

    An analytical method for the investigation of special types of dispersion relations is presented. In particular, analysis of the propagation of small-amplitude hydromagnetic waves in a collisionless plasma in a strong magnetic field leads to such dispersion relations. The fifth-degree dispersion relation corresponding to a particular case is considered. The necessary stability condition for a steady state and conditions for the degeneration of small-amplitude waves are derived. A comparison with other methods for the analysis of similar dispersion relations is also presented. (author)

  4. Numerical analytic continuation by a mollification method based on Hermite function expansion

    Science.gov (United States)

    Zhao, Zhenyu

    2012-04-01

    The numerical analytic continuation of a function f(z) = f(x + iy) on a strip is discussed in this paper. Data are only given approximately on the real axis. A mollification method based on expanded Hermite functions has been introduced to deal with the ill-posedness of the problem. We have shown that the mollification parameter can be chosen by a discrepancy principle and a corresponding error estimate has also been obtained. Numerical tests are given to show the effectiveness of the method.

  5. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    International Nuclear Information System (INIS)

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-01-01

    effectively remove inorganic chloride from the activated carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 g/L potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent column breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX

  6. An analytical solution for the nonlinear energy spectrum equation by the decomposition method

    Energy Technology Data Exchange (ETDEWEB)

    Goulart, A [Universidade Federal do Pampa, Av. Tiaraju810, 97546-550 Alegrete, RS (Brazil); Vilhena, M T M B de; Bodmann, B E J [Universidade Federal do Rio Grande do Sul, Av. Osvaldo Aranha 99/4, 90460-900 Porto Alegre, RS (Brazil); Moreira, D [Universidade Federal do Pampa, Rua Carlos Barbosa S/N, 96412-420 Bage, RS (Brazil)], E-mail: bardo.bodmann@ufrgs.br

    2008-10-24

    We discuss the isotropic turbulence decay and solve the energy density spectrum (EDS) equation considering the inertial transfer energy and viscosity terms, using the Heisenberg parameterization. In the present approach, buoyant and shear terms are neglected and turbulence is assumed to be homogeneous and isotropic. The nonlinear integro-differential equation is solved by Adomian's generic decomposition method, which yields an analytical recursive expression and upon truncation gives an approximate solution. We show the resulting EDS and the time-dependent decay of the intensity of the turbulent kinetic energy. Our results prove consistent the Heisenberg parameterization for the transfer term of the inertial energy. The analytical character of the solution permits a validation of the nonlinear details of the physical model.

  7. Field sampling and selecting on-site analytical methods for explosives in soil

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, A.B.; Craig, H.D.; Jenkins, T.F.; Sisk, W.E.

    1996-12-01

    A large number of defense-related sites are contaminated with elevated levels of secondary explosives. Levels of contamination range from barely detectable to levels above 10% that need special handling because of the detonation potential. Characterization of explosives-contaminated sites is particularly difficult because of the very heterogeneous distribution of contamination in the environment and within samples. To improve site characterization, several options exist including collecting more samples, providing on-site analytical data to help direct the investigation, compositing samples, improving homogenization of the samples, and extracting larger samples. This publication is intended to provide guidance to Remedial Project Managers regarding field sampling and on-site analytical methods for detecting and quantifying secondary explosive compounds in soils, and is not intended to include discussions of the safety issues associated with sites contaminated with explosive residues.

  8. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  9. Standard test methods for estimating the depth of decarburization of steel specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 These test methods cover procedures for estimating the depth of decarburization of steels irrespective of the composition, matrix microstructure, or section shape. The following basic procedures may be used: 1.1.1 Screening methods. 1.1.2 Microscopical methods. 1.1.3 Microindentation hardness methods. 1.1.4 Chemical analysis methods. 1.2 In case of a dispute, the rigorous quantitative or lineal analysis method (see 7.3.5 and 7.3.6) shall be the referee method. These methods can be employed with any cross-sectional shape. The chemical analytical methods generally reveal a greater depth of decarburization than the microscopical methods but are limited to certain simple shapes and by availability of equipment. These techniques are generally reserved for research studies. The microindentation hardness method is suitable for accurate measurements of hardened structures with relatively homogeneous microstructures. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound equivalents...

  10. Laboratory analytical methods for the determination of the hydrocarbon status of soils (a review)

    Science.gov (United States)

    Pikovskii, Yu. I.; Korotkov, L. A.; Smirnova, M. A.; Kovach, R. G.

    2017-10-01

    Laboratory analytical methods suitable for the determination of the hydrocarbon status of soils (a specific soil characteristic involving information on the total content and qualitative features of soluble (bitumoid) carbonaceous substances and individual hydrocarbons (polycyclic aromatic hydrocarbons, alkanes, etc.) in bitumoid, as well as the composition and content of hydrocarbon gases) have been considered. Among different physicochemical methods of study, attention is focused on the methods suitable for the wide use. Luminescence-bituminological analysis, low-temperature spectrofluorimetry (Shpolskii spectroscopy), infrared (IR) spectroscopy, gas chromatography, chromatography-mass spectrometry, and some other methods have been characterized, as well as sample preparation features. Advantages and limitations of each of these methods are described; their efficiency, instrumental complexity, analysis duration, and accuracy are assessed.

  11. Laboratory Techniques in Geology: Embedding Analytical Methods into the Undergraduate Curriculum

    Science.gov (United States)

    Baedke, S. J.; Johnson, E. A.; Kearns, L. E.; Mazza, S. E.; Gazel, E.

    2014-12-01

    Paid summer REU experiences successfully engage undergraduate students in research and encourage them to continue to graduate school and scientific careers. However these programs only accommodate a limited number of students due to funding constraints, faculty time commitments, and limited access to needed instrumentation. At JMU, the Department of Geology and Environmental Science has embedded undergraduate research into the curriculum. Each student fulfilling a BS in Geology or a BA in Earth Science completes 3 credits of research, including a 1-credit course on scientific communication, 2 credits of research or internship, followed by a presentation of that research. Our department has successfully acquired many analytical instruments and now has an XRD, SEM/EDS, FTIR, handheld Raman, AA, ion chromatograph, and an IRMS. To give as many students as possible an overview to the scientific uses and operation methods for these instruments, we revived a laboratory methods course that includes theory and practical use of instrumentation at JMU, plus XRF sample preparation and analysis training at Virginia Tech during a 1-day field trip. In addition to practical training, projects included analytical concepts such as evaluating analytical vs. natural uncertainty, determining error on multiple measurements, signal-to-noise ratio, and evaluating data quality. State funding through the 4-VA program helped pay for analytical supplies and support for students to complete research projects over the summer or during the next academic year using instrumentation from the course. This course exemplifies an alternative path to broadening participation in undergraduate research and creating stronger partnerships between PUI's and research universities.

  12. Novel analytical methods for characterising binding media and protective coatings in artworks

    International Nuclear Information System (INIS)

    Domenech-Carbo, Maria Teresa

    2008-01-01

    Since the first reported analytical studies and technical examinations of art and archaeological objects conducted in the late 18th century, analytical techniques and methods applied to the study of artworks have constantly grown. Among the materials composing the art object, organic compounds used as binding media or protective coatings have attracted the attention of the conservation profession given their noticeable ability for undergoing morphological and chemical changes on ageing. Thus, the aim of this paper is to review the most recent advances in the identification and determination of organic compounds present in art and art conservation materials. Immunofluorescence techniques have been proposed in recent decades as an alternative to the classical and simpler microchemical tests. Besides, a variety of instrumental techniques have also been improved in an attempt to enhance the sensitivity, repeatability and accuracy of the analytical results. Spectroscopic techniques, such as UV-vis, FTIR and Raman spectroscopy, have been coupled with light microscopes for these purposes. Synchrotron radiation FTIR microspectroscopy has also been successfully applied to the analysis of artworks. Mass spectrometry has also been increasingly used as a detector system coupled with a chromatographic device. Chromatographic methods have also improved in recent years. Paper and thin layer chromatographic techniques have been progressively replaced with gas chromatography (GC), pyrolysis-GC, high performance liquid chromatography and capillary electrophoresis. More complex proteomics hyphenated techniques, such as nano-liquid chromatography-nano-electrospray ionisation/collision quadrupole time-of-flight tandem mass spectrometry, have been recently applied to the identification and determination of proteinaceous binders. Microbeam analytical techniques have also been incorporated into the list of advanced instrumental techniques for art conservation purposes. Finally, a number

  13. Semi-analytical method for calculating aeroelastic effect of profiled rod flying at high velocity

    Directory of Open Access Journals (Sweden)

    Hui-jun Ning

    2015-03-01

    Full Text Available The key technique of a kinetic energy rod (KER warhead is to control the flight attitude of rods. The rods are usually designed to different shapes. A new conceptual KER named profiled rod which has large L/D ratio is described in this paper. The elastic dynamic equations of this profiled rod flying at high velocity after detonation are set up on the basis of Euler-Bernoulli beam, and the aeroelastic deformation of profiled rod is calculated by semi-analytical method for calculating the vibration characteristics of variable cross-section beam. In addition, the aeroelastic deformation of the undeformed profiled rod and the aeroelastic deformation of deformed profiled rod which is caused by the detonation of explosive are simulated by computational fluid dynamic and finite element method (CFD/FEM, respectively. A satisfactory agreement of these two methods is obtained by the comparison of two methods. The results show that the semi-analytical method for calculating the vibration characteristics of variable cross-section beam is applied to analyze the aeroelastic deformation of profiled rod flying at high velocity.

  14. Simplex and duplex event-specific analytical methods for functional biotech maize.

    Science.gov (United States)

    Lee, Seong-Hun; Kim, Su-Jeong; Yi, Bu-Young

    2009-08-26

    Analytical methods are very important in the control of genetically modified organism (GMO) labeling systems or living modified organism (LMO) management for biotech crops. Event-specific primers and probes were developed for qualitative and quantitative analysis for biotech maize event 3272 and LY 038 on the basis of the 3' flanking regions, respectively. The qualitative primers confirmed the specificity by a single PCR product and sensitivity to 0.05% as a limit of detection (LOD). Simplex and duplex quantitative methods were also developed using TaqMan real-time PCR. One synthetic plasmid was constructed from two taxon-specific DNA sequences of maize and two event-specific 3' flanking DNA sequences of event 3272 and LY 038 as reference molecules. In-house validation of the quantitative methods was performed using six levels of mixing samples, from 0.1 to 10.0%. As a result, the biases from the true value and the relative deviations were all within the range of +/-30%. Limits of quantitation (LOQs) of the quantitative methods were all 0.1% for simplex real-time PCRs of event 3272 and LY 038 and 0.5% for duplex real-time PCR of LY 038. This study reports that event-specific analytical methods were applicable for qualitative and quantitative analysis for biotech maize event 3272 and LY 038.

  15. Determination of uranium in soil samples by different analytical extraction methods

    International Nuclear Information System (INIS)

    Knopke, J.; Sachse, R.

    1986-01-01

    As an approach for the development of a suitable analytic method for determining the uranium in soil that can be taken up by plants, the following analytical extraction methods are compared: 5M HNO 3 , HF for determination of uranium content, 0.05M MgCl 2 , and malate. The tests are made with various concentrations and extraction temperatures. MgCl 2 and malate leave the grain size spectrum of the soil samples untouched, other than the HNO 3 or HF method, and thus avoid the artificial weathering of the minerals and the resulting uranium release. The correlation of uranium content in soil and plant serves as a measure of evaluating the reliability of a method with regard to the uranium available for uptake. The method using malate is far better in terms of reliability under certain reaction conditions. This is why organic acids are classified to be suitable for determination of the uranium available for uptake by plants. (orig./PW) [de

  16. Method development and validation for dieckol in the standardization of phlorotannin preparations

    Directory of Open Access Journals (Sweden)

    Jiyoung Kim

    2016-03-01

    Full Text Available Abstract Phlorotannins are reported to have diverse biological properties. However, no analytical methods for the standardization of phlorotannin preparations have been reported. Herein, we developed and validated an analytical method for the determination of dieckol in phlorotannin extracts (PRT using high-performance liquid chromatography (HPLC. The optimum HPLC conditions consisted of a Supelco Discovery C18 column stationary phase, a mobile phase (A: 15 % HPLC grade methanol in deionized water, B: methanol, UV detection at 230 nm, and a flow rate of 0.7 mL/min. The optimized chromatographic conditions were validated and exhibited good specificity and linearity (R 2 > 0.9994–1.0000. The recoveries were in the range of 100.9–102.3 %. The method had good intermediate (%RSD 1.2 and intra-day (%RSD 0.4–1.7 assay precisions. This HPLC method had good accuracy and quality in the determination of dieckol in PRT.

  17. 49V Standardization by the CIEMAT/NIST LSC method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez, A.; Ortiz, F.

    1998-01-01

    The sample preparation procedure for LSC standardization of a solution of 49 VCl 5 is described and the time stability of samples is analyzed in four commercial scintillators, HiSafe II, HiSafe III, Ultima-Gold and Insta-Gel Plus. Acceptable stability was obtained in HiSafe III and Ultima-Gold. A self-consistent procedure was developed and successfully applied to the determination of the activity concentration of 49 V. The samples were standardized by the CIEMAT/NIST method to a combined uncertainty of 3.4% in the interval of figure of merit 1.2-2.5 ( 3 H equivalent efficiency 40%-20%)

  18. Improving healthcare middleware standards with semantic methods and technologies.

    Science.gov (United States)

    Román, Isabel; Calvillo, Jorge; Roa, Laura M; Madinabeitia, Germán

    2008-01-01

    A critical issue in healthcare informatics is to facilitate the integration and interoperability of applications. This goal can be achieved through an open architecture based on a middleware independent from specific applications; useful for working with existing systems, as well as for the integration of new systems. Several standard organizations are making efforts toward this target. This work is based on the EN 12967-1,2,3, developed by CEN, that follows the ODP (Open Distributed Processing) methodology, providing a specification of distributed systems based on the definition of five viewpoints. However, only the three upper viewpoints are used to produce EN 12967, the two lower viewpoints should be considered in the implementation context. We are using Semantic Grid for lower views and Semantic Web and Web Services for the definition of the upper views. We analyze benefits of using these methods and technologies and expose methodology for the development of this semantic healthcare middleware observing European Standards.

  19. THE STANDARDIZED CANDLE METHOD FOR TYPE II PLATEAU SUPERNOVAE

    International Nuclear Information System (INIS)

    Olivares E, Felipe; Hamuy, Mario; Pignata, Giuliano; Maza, Jose; Bersten, Melina; Phillips, Mark M.; Morrel, Nidia I.; Suntzeff, Nicholas B.; Filippenko, Alexei V.; Kirshner, Robert P.; Matheson, Thomas

    2010-01-01

    In this paper, we study the 'standardized candle method' using a sample of 37 nearby (redshift z V ) = 0.2 mag. The correlation between plateau luminosity and expansion velocity previously reported in the literature is recovered. Using this relation and assuming a standard reddening law (R V = 3.1), we obtain Hubble diagrams (HDs) in the BVI bands with dispersions of ∼0.4 mag. Allowing R V to vary and minimizing the spread in the HDs, we obtain a dispersion range of 0.25-0.30 mag, which implies that these objects can deliver relative distances with precisions of 12%-14%. The resulting best-fit value of R V is 1.4 ± 0.1.

  20. Standard CMMIsm Appraisal Method for Process Improvement (SCAMPIsm), Version 1.1: Method Definition Document

    National Research Council Canada - National Science Library

    2001-01-01

    The Standard CMMI Appraisal Method for Process Improvement (SCAMPI(Service Mark)) is designed to provide benchmark quality ratings relative to Capability Maturity Model(registered) Integration (CMMI(Service Mark)) models...

  1. Volatile organic silicon compounds in biogases: development of sampling and analytical methods for total silicon quantification by ICP-OES.

    Science.gov (United States)

    Chottier, Claire; Chatain, Vincent; Julien, Jennifer; Dumont, Nathalie; Lebouil, David; Germain, Patrick

    2014-01-01

    Current waste management policies favor biogases (digester gases (DGs) and landfill gases (LFGs)) valorization as it becomes a way for energy politics. However, volatile organic silicon compounds (VOSiCs) contained into DGs/LFGs severely damage combustion engines and endanger the conversion into electricity by power plants, resulting in a high purification level requirement. Assessing treatment efficiency is still difficult. No consensus has been reached to provide a standardized sampling and quantification of VOSiCs into gases because of their diversity, their physicochemical properties, and the omnipresence of silicon in analytical chains. Usually, samplings are done by adsorption or absorption and quantification made by gas chromatography-mass spectrometry (GC-MS) or inductively coupled plasma-optical emission spectrometry (ICP-OES). In this objective, this paper presents and discusses the optimization of a patented method consisting in VOSiCs sampling by absorption of 100% ethanol and quantification of total Si by ICP-OES.

  2. Multigroup, spatial kinetics for MOX-fueled LWRs based on harmonic analytical nodal method

    Science.gov (United States)

    Jiang, Guobing

    2000-10-01

    There has been substantial evidence during the last several years that the core neutronics methods that have been developed for uranium fueled LWRs do not perform satisfactorily when applied to the same cores fueled with mixed oxide, or more generally to heterogeneous cores with very different neutron spectra. A two-dimensional, 97 group MOX benchmark problem was developed and applied to analyze deficiencies of the current generation of LWR analysis methods. The errors in the current two group, coarse mesh nodal diffusion methods were described in terms of four primary effects: (1) a homogenization effect, (2) a spatial discretization effect, (3) a group collapsing effect, and (4) a transport effect. The specific objective of the research here was to address the first three of these effects with the development of a four energy group advanced nodal method. Several methods have been proposed over the last several years for extending the current class of nodal methods to four energy groups. A Taylor series analysis was performed of the order of error in the various analytic nodal methods proposed. The analysis showed that the harmonic part of the error dominated in the Taylor expansion and it was therefore prudent to retain the harmonic solution in all four energy groups. A new nodal kernel referred to as the Harmonic Analytic Nodal Method (HANM) was developed and implemented within the framework of the nonlinear nodal method. HANM was applied to a MOX benchmark problem and results were compared to a 97 group reference solution. The errors in the two group solution were reduced by about 50% through the application of a four group HANM with minimal increase in the computational burden.

  3. Changes in the Concentrations of Corticoid Metabolites – The Effect of Stress, Diet and Analytical Method

    Directory of Open Access Journals (Sweden)

    Michaela Dušková

    2015-01-01

    Full Text Available A precisely measured corticoid level is important for decision-making in daily clinical practice. These levels can be influenced in the pre-analytical phase, when the effect of stress, timing, and diet can be important. The aim of this study was to elucidate optimal conditions for blood sampling as well as the choice of analytical methods, which they will be used in measuring of corticoids. By studying ten women, we focused on the influences of the stress of cannulation and a large lunchtime meal on cortisol, cortisone, aldosterone and corticosterone levels. We further compared results of cortisol measurements from RIA and LC-MS/MS. Stress from cannulation caused increase of cortisol, cortisone and corticosterone already, when the cannula was being inserted. This indicates that this increase is stimulated by fear of the blood withdrawing rather, than just by the needle insertion itself. The effect of stress on corticosterone disappeared after an hour, while effect on other corticoids was still apparent. Concerning the lunchtime meal, we found an increase in all measured corticoids between 11 and 12 o’clock. After the food, there were marked decreases in cortisone and aldosterone, while declining levels of cortisol and corticosterone had rather plateaus. We compared cortisol in 90 plasma samples measured by a commercial RIA kit and the LC-MS/MS method. Results from both methods showed a strong correlation (r=0.85. When measuring corticoid metabolites, the chosen analytical method, eliminating stress factors, and precisely timed blood sampling considering the daily rhythm and food intake are critical.

  4. Analytical solutions of convection–diffusion problems by combining Laplace transform method and homotopy perturbation method

    Directory of Open Access Journals (Sweden)

    Sumit Gupta

    2015-09-01

    Full Text Available The aim of this paper was to present a user friendly numerical algorithm based on homotopy perturbation transform method for solving various linear and nonlinear convection-diffusion problems arising in physical phenomena where particles, energy, or other physical quantities are transferred inside a physical system due to two processes: diffusion and convection. The homotopy perturbation transform method is a combined form of the homotopy perturbation method and Laplace transform method. The nonlinear terms can be easily obtained by the use of He’s polynomials. The technique presents an accurate methodology to solve many types of partial differential equations The approximate solutions obtained by proposed scheme in a wide range of the problem’s domain were compared with those results obtained from the actual solutions. The comparison shows a precise agreement between the results.

  5. Application of the invariant embedding method to analytically solvable transport problems

    International Nuclear Information System (INIS)

    Wahlberg, Malin

    2005-05-01

    The applicability and performance of the invariant embedding method for calculating various transport quantities is investigated in this thesis. The invariant embedding method is a technique to calculate the reflected or transmitted fluxes in homogeneous half-spaces and slabs, without the need for solving for the flux inside the medium. In return, the embedding equations become non-linear, and in practical cases they need to be solved by numerical methods. There are, however, fast and effective iterative methods available for this purpose. The objective of this thesis is to investigate the performance of these iterative methods in model problems, in which also an exact analytical solution can be obtained. Some of these analytical solutions are also new, hence their derivation constitutes a part of the thesis work. The cases investigated in the thesis all concern the calculation of reflected fluxes from half-spaces. The first problem treated was the calculation of the energy spectrum of reflected (sputtered) particles from a multiplying medium, where the multiplication arises from recoil production (i.e. like binary fission), when bombarded by o flux of monoenergetic particles of the same type. Both constant cross sections and energy dependent cross sections with a power law dependence were used in the calculations. The second class of problems concerned the calculation of the path length distribution of reflected particles from a medium without multiplication. It is an interesting new observation that the distribution of the path length travelled in the medium before reflection can be calculated with invariant embedding methods, which actually do not solve the flux distribution in the medium. We have tested the accuracy and the convergence properties of the embedding method also for this case. Finally, very recently a theory of connecting the infinite and half-space medium solutions by embedding-like integral equations was developed and reported in the literature

  6. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  7. Analytical solutions for solute transport in groundwater and riverine flow using Green's Function Method and pertinent coordinate transformation method

    Science.gov (United States)

    Sanskrityayn, Abhishek; Suk, Heejun; Kumar, Naveen

    2017-04-01

    In this study, analytical solutions of one-dimensional pollutant transport originating from instantaneous and continuous point sources were developed in groundwater and riverine flow using both Green's Function Method (GFM) and pertinent coordinate transformation method. Dispersion coefficient and flow velocity are considered spatially and temporally dependent. The spatial dependence of the velocity is linear, non-homogeneous and that of dispersion coefficient is square of that of velocity, while the temporal dependence is considered linear, exponentially and asymptotically decelerating and accelerating. Our proposed analytical solutions are derived for three different situations depending on variations of dispersion coefficient and velocity, respectively which can represent real physical processes occurring in groundwater and riverine systems. First case refers to steady solute transport situation in steady flow in which dispersion coefficient and velocity are only spatially dependent. The second case represents transient solute transport in steady flow in which dispersion coefficient is spatially and temporally dependent while the velocity is spatially dependent. Finally, the third case indicates transient solute transport in unsteady flow in which both dispersion coefficient and velocity are spatially and temporally dependent. The present paper demonstrates the concentration distribution behavior from a point source in realistically occurring flow domains of hydrological systems including groundwater and riverine water in which the dispersivity of pollutant's mass is affected by heterogeneity of the medium as well as by other factors like velocity fluctuations, while velocity is influenced by water table slope and recharge rate. Such capabilities give the proposed method's superiority about application of various hydrological problems to be solved over other previously existing analytical solutions. Especially, to author's knowledge, any other solution doesn

  8. Evaluation of FTIR-based analytical methods for the analysis of simulated wastes

    International Nuclear Information System (INIS)

    Rebagay, T.V.; Cash, R.J.; Dodd, D.A.; Lockrem, L.L.; Meacham, J.E.; Winkelman, W.D.

    1994-01-01

    Three FTIR-based analytical methods that have potential to characterize simulated waste tank materials have been evaluated. These include: (1) fiber optics, (2) modular transfer optic using light guides equipped with non-contact sampling peripherals, and (3) photoacoustic spectroscopy. Pertinent instrumentation and experimental procedures for each method are described. The results show that the near-infrared (NIR) region of the infrared spectrum is the region of choice for the measurement of moisture in waste simulants. Differentiation of the NIR spectrum, as a preprocessing steps, will improve the analytical result. Preliminary data indicate that prominent combination bands of water and the first overtone band of the ferrocyanide stretching vibration may be utilized to measure water and ferrocyanide species simultaneously. Both near-infrared and mid-infrared spectra must be collected, however, to measure ferrocyanide species unambiguously and accurately. For ease of sample handling and the potential for field or waste tank deployment, the FTIR-Fiber Optic method is preferred over the other two methods. Modular transfer optic using light guides and photoacoustic spectroscopy may be used as backup systems and for the validation of the fiber optic data

  9. Performances of analytical methods for freshwater analysis assessed through intercomparison exercises. II. Major ions.

    Directory of Open Access Journals (Sweden)

    Herbert MUNTAU

    1999-02-01

    Full Text Available From 1991 to 1997, nine intercomparison exercises on rainwater and freshwater samples were held in the framework of an activity connecting laboratories participating in different projects (Environmental studies in the Mediterranean basin, Italian network for the study of wet deposition, Acidification of mountain lakes, Limnological studies of Lake Léman, Monitoring of atmospheric deposition in forests. The number of participants increased from 72 in 1991 to 177 in 1997. Among the measured variables (pH, conductivity, alkalinity, major ions and nutrients, Ca, Mg, Na, K, ammonium, sulphate, chloride and nitrate are considered in this paper. The methods commonly used by the laboratories involved in the exercises are compared for precision, and an estimate of the performance of each method at different concentrations is made. The results show that some of the participating laboratories use analytical methods which are not reliable for the concentration values occurring in freshwater and/or in rainwater. However, outliers are also produced by laboratories using well-performing methods, indicating the importance of introducing analytical control procedures.

  10. A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens

    Directory of Open Access Journals (Sweden)

    Cristina Portalés

    2017-06-01

    Full Text Available The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, where a sample is shown for a virtual reality Formula 1 simulator that has a cylindrical screen. The proposed method results from the combination of surveying, photogrammetry and image processing approaches, and has been designed by considering the spatial restrictions of virtual reality simulators. The method has been validated from a mathematical point of view, and the complete system—which is currently installed in a shopping mall in Spain—has been tested by different users.

  11. The eXtensible Access Method (XAM Standard

    Directory of Open Access Journals (Sweden)

    Steve Todd

    2009-10-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 Recent developments in the storage industry have resulted in the creation of an industry standard application programmer’s interface (API known as XAM, the eXtensible Access Method. The XAM API focuses on the creation and management of reference information (otherwise known as fixed content. Storage vendors supporting the XAM API will provide new benefits to applications that are creating and managing large amounts of fixed content. The benefits described by this paper merit consideration and research by developers creating applications for Digital Curators.

  12. Analytical methods in sphingolipidomics: Quantitative and profiling approaches in food analysis.

    Science.gov (United States)

    Canela, Núria; Herrero, Pol; Mariné, Sílvia; Nadal, Pedro; Ras, Maria Rosa; Rodríguez, Miguel Ángel; Arola, Lluís

    2016-01-08

    In recent years, sphingolipidomics has emerged as an interesting omic science that encompasses the study of the full sphingolipidome characterization, content, structure and activity in cells, tissues or organisms. Like other omics, it has the potential to impact biomarker discovery, drug development and systems biology knowledge. Concretely, dietary food sphingolipids have gained considerable importance due to their extensively reported bioactivity. Because of the complexity of this lipid family and their diversity among foods, powerful analytical methodologies are needed for their study. The analytical tools developed in the past have been improved with the enormous advances made in recent years in mass spectrometry (MS) and chromatography, which allow the convenient and sensitive identification and quantitation of sphingolipid classes and form the basis of current sphingolipidomics methodologies. In addition, novel hyphenated nuclear magnetic resonance (NMR) strategies, new ionization strategies, and MS imaging are outlined as promising technologies to shape the future of sphingolipid analyses. This review traces the analytical methods of sphingolipidomics in food analysis concerning sample extraction, chromatographic separation, the identification and quantification of sphingolipids by MS and their structural elucidation by NMR. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders - A Reference Solution for the Numerical Method of Auxiliary Sources

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    To facilitate the validation of the numerical Method of Auxiliary Sources an analytical Method of Auxiliary Sources solution is derived in this paper. The Analytical solution is valid for transverse magnetic, and electric, plane wave scattering by circular impedance Cylinders, and it is derived b...

  14. Simplified Analytical Method for Optimized Initial Shape Analysis of Self-Anchored Suspension Bridges and Its Verification

    Directory of Open Access Journals (Sweden)

    Myung-Rag Jung

    2015-01-01

    Full Text Available A simplified analytical method providing accurate unstrained lengths of all structural elements is proposed to find the optimized initial state of self-anchored suspension bridges under dead loads. For this, equilibrium equations of the main girder and the main cable system are derived and solved by evaluating the self-weights of cable members using unstrained cable lengths and iteratively updating both the horizontal tension component and the vertical profile of the main cable. Furthermore, to demonstrate the validity of the simplified analytical method, the unstrained element length method (ULM is applied to suspension bridge models based on the unstressed lengths of both cable and frame members calculated from the analytical method. Through numerical examples, it is demonstrated that the proposed analytical method can indeed provide an optimized initial solution by showing that both the simplified method and the nonlinear FE procedure lead to practically identical initial configurations with only localized small bending moment distributions.

  15. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  16. Analytical X-ray microscopy using laboratory sources: Method and results

    International Nuclear Information System (INIS)

    Wulveryck, J.M.; Odof, S.; Patat, J.M.; Mouze, D.

    2000-01-01

    The implementation of X-ray imaging techniques (X-Ray Projection Microscopy or X-Ray Microtomography) for analytical purpose with laboratory equipment is not easily obtainable, due to the use of polychromatic X-ray sources. To overcome this drawback, we propose here a mathematical technique based upon the calculation of the X-ray emission spectra and the knowledge of the spectral response of the camera. For example, we show that the composition of a ternary sample can be deduced from two images measurements recorded from two primary radiation. The accuracy of the method is discussed

  17. A Comparison of Two Approaches for the Ruggedness Testing of an Analytical Method

    International Nuclear Information System (INIS)

    Maestroni, Britt

    2016-01-01

    As part of an initiative under the “Red Analitica de Latino America y el Caribe” (RALACA) network the FAO/IAEA Food and Environmental Protection Laboratory validated a multi-residue method for pesticides in potato. One of the parameters to be assessed was the intra laboratory robustness or ruggedness. The objective of this work was to implement a worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method. As a conclusion to this study, it is evident that there is a need for harmonization of the definition of the terms robustness/ruggedness, the limits, the methodology and the statistical treatment of the generated data. A worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method will soon be posted on the RALACA website (www.red-ralaca.net). This study was carried out with collaborators from LVA (Austria), University of Antwerp (Belgium), University of Leuwen (The Netherlands), Universidad de la Republica (Uruguay) and Agilent technologies.

  18. Selection and authentication of botanical materials for the development of analytical methods.

    Science.gov (United States)

    Applequist, Wendy L; Miller, James S

    2013-05-01

    Herbal products, for example botanical dietary supplements, are widely used. Analytical methods are needed to ensure that botanical ingredients used in commercial products are correctly identified and that research materials are of adequate quality and are sufficiently characterized to enable research to be interpreted and replicated. Adulteration of botanical material in commerce is common for some species. The development of analytical methods for specific botanicals, and accurate reporting of research results, depend critically on correct identification of test materials. Conscious efforts must therefore be made to ensure that the botanical identity of test materials is rigorously confirmed and documented through preservation of vouchers, and that their geographic origin and handling are appropriate. Use of material with an associated herbarium voucher that can be botanically identified is always ideal. Indirect methods of authenticating bulk material in commerce, for example use of organoleptic, anatomical, chemical, or molecular characteristics, are not always acceptable for the chemist's purposes. Familiarity with botanical and pharmacognostic literature is necessary to determine what potential adulterants exist and how they may be distinguished.

  19. Analytical methods applied to the study of lattice gauge and spin theories

    International Nuclear Information System (INIS)

    Moreo, Adriana.

    1985-01-01

    A study of interactions between quarks and gluons is presented. Certain difficulties of the quantum chromodynamics to explain the behaviour of quarks has given origin to the technique of lattice gauge theories. First the phase diagrams of the discrete space-time theories are studied. The analysis of the phase diagrams is made by numerical and analytical methods. The following items were investigated and studied: a) A variational technique was proposed to obtain very accurated values for the ground and first excited state energy of the analyzed theory; b) A mean-field-like approximation for lattice spin models in the link formulation which is a generalization of the mean-plaquette technique was developed; c) A new method to study lattice gauge theories at finite temperature was proposed. For the first time, a non-abelian model was studied with analytical methods; d) An abelian lattice gauge theory with fermionic matter at the strong coupling limit was analyzed. Interesting results applicable to non-abelian gauge theories were obtained. (M.E.L.) [es

  20. Problem of the Moving Boundary in Continuous Casting Solved by The Analytic-Numerical Method

    Directory of Open Access Journals (Sweden)

    Grzymkowski R.

    2013-03-01

    Full Text Available Mathematical modeling of thermal processes combined with the reversible phase transitions of type: solid phase - liquid phase leads to formulation of the parabolic or elliptic moving boundary problem. Solution of such defined problem requires, most often, to use some sophisticated numerical techniques and far advanced mathematical tools. The paper presents an analytic-numerical method, especially attractive from the engineer’s point of view, applied for finding the approximate solutions of the selected class of problems which can be reduced to the one-phase solidification problem of a plate with the unknown a priori, varying in time boundary of the region in which the solution is sought. Proposed method is based on the known formalism of initial expansion of a sought function, describing the field of temperature, into the power series, some coefficients of which are determined with the aid of boundary conditions, and on the approximation of a function defining the freezing front location with the broken line, parameters of which are determined numerically. The method represents a combination of the analytical and numerical techniques and seems to be an effective and relatively easy in using tool for solving problems of considered kind.