WorldWideScience

Sample records for standard administrative code

  1. Code, standard and specifications

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography also same as the other technique, it need standard. This standard was used widely and method of used it also regular. With that, radiography testing only practical based on regulations as mentioned and documented. These regulation or guideline documented in code, standard and specifications. In Malaysia, level one and basic radiographer can do radiography work based on instruction give by level two or three radiographer. This instruction was produced based on guideline that mention in document. Level two must follow the specifications mentioned in standard when write the instruction. From this scenario, it makes clearly that this radiography work is a type of work that everything must follow the rule. For the code, the radiography follow the code of American Society for Mechanical Engineer (ASME) and the only code that have in Malaysia for this time is rule that published by Atomic Energy Licensing Board (AELB) known as Practical code for radiation Protection in Industrial radiography. With the existence of this code, all the radiography must follow the rule or standard regulated automatically.

  2. Tribal Green Building Administrative Code Example

    Science.gov (United States)

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  3. Cross-Index to DOE-prescribed industrial safety codes and standards

    International Nuclear Information System (INIS)

    1980-01-01

    This Cross-Index volume is the 1980 compilation of detailed information from more than two hundred and ninety Department of Energy (DOE) prescribed or Occupational Health and Safety Administration (OSHA) referenced industrial safety codes and standards. The compilation of this material was conceived and initiated in 1973, and is revised yearly to provide information from current codes. Condensed data from individual code portions are listed according to reference code, section, paragraph, and page. Each code is given a two-digit reference code number or letter in the Contents section. This reference code provides ready identification of any code listed in the Cross-Index. The computerized information listings are on the left-hand portion of Cross-Index page; in order to the right of the listing are the reference code letters or numbers, the section, paragraph, and page of the referenced code containing expanded information on the individual listing. Simplified How to Use directions are listed. A glossary of letter initials/abbreviations for the organizations or documents, whose codes or standards are contained in this Cross-Index, is included

  4. Office of Codes and Standards resource book. Section 1, Building energy codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1995-01-01

    The US Department of Energy`s (DOE`s) Office of Codes and Standards has developed this Resource Book to provide: A discussion of DOE involvement in building codes and standards; a current and accurate set of descriptions of residential, commercial, and Federal building codes and standards; information on State contacts, State code status, State building construction unit volume, and State needs; and a list of stakeholders in the building energy codes and standards arena. The Resource Book is considered an evolving document and will be updated occasionally. Users are requested to submit additional data (e.g., more current, widely accepted, and/or documented data) and suggested changes to the address listed below. Please provide sources for all data provided.

  5. Atlas C++ Coding Standard Specification

    CERN Document Server

    Albrand, S; Barberis, D; Bosman, M; Jones, B; Stavrianakou, M; Arnault, C; Candlin, D; Candlin, R; Franck, E; Hansl-Kozanecka, Traudl; Malon, D; Qian, S; Quarrie, D; Schaffer, R D

    2001-01-01

    This document defines the ATLAS C++ coding standard, that should be adhered to when writing C++ code. It has been adapted from the original "PST Coding Standard" document (http://pst.cern.ch/HandBookWorkBook/Handbook/Programming/programming.html) CERN-UCO/1999/207. The "ATLAS standard" comprises modifications, further justification and examples for some of the rules in the original PST document. All changes were discussed in the ATLAS Offline Software Quality Control Group and feedback from the collaboration was taken into account in the "current" version.

  6. A repository of codes of ethics and technical standards in health informatics.

    Science.gov (United States)

    Samuel, Hamman W; Zaïane, Osmar R

    2014-01-01

    We present a searchable repository of codes of ethics and standards in health informatics. It is built using state-of-the-art search algorithms and technologies. The repository will be potentially beneficial for public health practitioners, researchers, and software developers in finding and comparing ethics topics of interest. Public health clinics, clinicians, and researchers can use the repository platform as a one-stop reference for various ethics codes and standards. In addition, the repository interface is built for easy navigation, fast search, and side-by-side comparative reading of documents. Our selection criteria for codes and standards are two-fold; firstly, to maintain intellectual property rights, we index only codes and standards freely available on the internet. Secondly, major international, regional, and national health informatics bodies across the globe are surveyed with the aim of understanding the landscape in this domain. We also look at prevalent technical standards in health informatics from major bodies such as the International Standards Organization (ISO) and the U. S. Food and Drug Administration (FDA). Our repository contains codes of ethics from the International Medical Informatics Association (IMIA), the iHealth Coalition (iHC), the American Health Information Management Association (AHIMA), the Australasian College of Health Informatics (ACHI), the British Computer Society (BCS), and the UK Council for Health Informatics Professions (UKCHIP), with room for adding more in the future. Our major contribution is enhancing the findability of codes and standards related to health informatics ethics by compilation and unified access through the health informatics ethics repository.

  7. Codes and Standards Technical Team Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-06-01

    The Hydrogen Codes and Standards Tech Team (CSTT) mission is to enable and facilitate the appropriate research, development, & demonstration (RD&D) for the development of safe, performance-based defensible technical codes and standards that support the technology readiness and are appropriate for widespread consumer use of fuel cells and hydrogen-based technologies with commercialization by 2020. Therefore, it is important that the necessary codes and standards be in place no later than 2015.

  8. Accuracy of Administrative Codes for Distinguishing Positive Pressure Ventilation from High-Flow Nasal Cannula.

    Science.gov (United States)

    Good, Ryan J; Leroue, Matthew K; Czaja, Angela S

    2018-06-07

    Noninvasive positive pressure ventilation (NIPPV) is increasingly used in critically ill pediatric patients, despite limited data on safety and efficacy. Administrative data may be a good resource for observational studies. Therefore, we sought to assess the performance of the International Classification of Diseases, Ninth Revision procedure code for NIPPV. Patients admitted to the PICU requiring NIPPV or heated high-flow nasal cannula (HHFNC) over the 11-month study period were identified from the Virtual PICU System database. The gold standard was manual review of the electronic health record to verify the use of NIPPV or HHFNC among the cohort. The presence or absence of a NIPPV procedure code was determined by using administrative data. Test characteristics with 95% confidence intervals (CIs) were generated, comparing administrative data with the gold standard. Among the cohort ( n = 562), the majority were younger than 5 years, and the most common primary diagnosis was bronchiolitis. Most (82%) required NIPPV, whereas 18% required only HHFNC. The NIPPV code had a sensitivity of 91.1% (95% CI: 88.2%-93.6%) and a specificity of 57.6% (95% CI: 47.2%-67.5%), with a positive likelihood ratio of 2.15 (95% CI: 1.70-2.71) and negative likelihood ratio of 0.15 (95% CI: 0.11-0.22). Among our critically ill pediatric cohort, NIPPV procedure codes had high sensitivity but only moderate specificity. On the basis of our study results, there is a risk of misclassification, specifically failure to identify children who require NIPPV, when using administrative data to study the use of NIPPV in this population. Copyright © 2018 by the American Academy of Pediatrics.

  9. Nevada Administrative Code for Special Education Programs.

    Science.gov (United States)

    Nevada State Dept. of Education, Carson City. Special Education Branch.

    This document presents excerpts from Chapter 388 of the Nevada Administrative Code, which concerns definitions, eligibility, and programs for students who are disabled or gifted/talented. The first section gathers together 36 relevant definitions from the Code for such concepts as "adaptive behavior,""autism,""gifted and…

  10. Building Standards and Codes for Energy Conservation

    Science.gov (United States)

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  11. Nondestructive testing standards and the ASME code

    International Nuclear Information System (INIS)

    Spanner, J.C.

    1991-04-01

    Nondestructive testing (NDT) requirements and standards are an important part of the ASME Boiler and Pressure Vessel Code. In this paper, the evolution of these requirements and standards is reviewed in the context of the unique technical and legal stature of the ASME Code. The coherent and consistent manner by which the ASME Code rules are organized is described, and the interrelationship between the various ASME Code sections, the piping codes, and the ASTM Standards is discussed. Significant changes occurred in ASME Sections 5 and 11 during the 1980s, and these are highlighted along with projections and comments regarding future trends and changes in these important documents. 4 refs., 8 tabs

  12. Alternative Fuels Data Center: Codes and Standards Resources

    Science.gov (United States)

    resources linked below help project developers and code officials prepare and review code-compliant projects , storage, and infrastructure. The following charts show the SDOs responsible for these alternative fuel codes and standards. Biodiesel Vehicle and Infrastructure Codes and Standards Chart Electric Vehicle and

  13. ASME nuclear codes and standards: Scope of coverage and current initiatives

    International Nuclear Information System (INIS)

    Eisenberg, G. M.

    1995-01-01

    The objective of this paper is to address the broad scope of coverage of nuclear codes, standards and guides produced and administered by the American Society of Mechanical Engineers (ASME). Background information is provided regarding the evolution of the present activities. Details are provided on current initiatives intended to permit ASME to meet the needs of a changing nuclear industry on a worldwide scale. During the early years of commercial nuclear power, ASME produced a code for the construction of nuclear vessels used in the reactor coolant pressure boundary, containment and auxiliary systems. In response to industry growth, ASME Code coverage soon broadened to include rules for construction of other nuclear components, and inservice inspection of nuclear reactor coolant systems. In the years following this, the scope of ASME nuclear codes, standards and guides has been broadened significantly to include air cleaning activities for nuclear power reactors, operation and maintenance of nuclear power plants, quality assurance programs, cranes for nuclear facilities, qualification of mechanical equipment, and concrete reactor vessels and containments. ASME focuses on globalization of its codes, standards and guides by encouraging and promoting their use in the international community and by actively seeking participation of international members on its technical and supervisory committees and in accreditation activities. Details are provided on current international representation. Initiatives are underway to separate the technical requirements from administrative and enforcement requirements, to convert to hard metric units, to provide for non-U. S. materials, and to provide for translations into non-English languages. ASME activity as an accredited ISO 9000 registrar for suppliers of mechanical equipment is described. Rules are being developed for construction of containment systems for nuclear spent fuel and high-level waste transport packagings. Intensive

  14. Recent activities on nuclear codes and standards

    International Nuclear Information System (INIS)

    Minematsu, Akiyoshi; Ishimoto, Shozaburo; Honjin, Masao

    2000-01-01

    The technical codes and standards relating to the nuclear power stations in Japan are prepared by shapes of laws (ministerial ordinances and bulletins) issued by the government and obliged to comply with by 'the Law concerning the Regulations of Nuclear Material Substances, Nuclear Fuel Substances and Nuclear Reactors' and 'the Electricity Business Act' and of guides defined by the Nuclear Safety Commission, and further some private standards have been issued at a shape of complement of these laws and guides by receiving national recommendation. On the other hand, in the fields of electricity and heat facilities except atomic energy, simplification and feature stipulation of the national technical codes and standards was recently carried out, by which a system usable for the private standards in and out of Japan were prepared through approval of the private Japan Electrotechnical Standards and Codes Committee (JESC). As the nuclear field was now excepted from simultaneous transfer to the private standard and the standard application system, it is expected in future to realize similar transfer if possible and preparation of the private standards is now being advanced. Here were introduced on present state on technical codes and standards relating to the nuclear power generation facilities and recent trends on their private standardization. (G.K.)

  15. ASME nuclear codes and standards: Recent technical initiatives

    International Nuclear Information System (INIS)

    Feigel, R. E.

    1995-01-01

    Although nuclear power construction is currently in a hiatus in the US, ASME and its volunteer committees remain committed to continual improvements in the technical requirements in its nuclear codes. This paper provides an overview of several significant recent revisions to ASME' s nuclear codes. Additionally, other important initiatives currently being addressed by ASME committees will be described. With the largest population of operating light water nuclear plants in the world and worldwide use of its nuclear codes, ASME continues to support technical advancements in its nuclear codes and standards. While revisions of various magnitude are an ongoing process, several recent revisions embody significant changes based on state of the art design philosophy and substantial industry experience. In the design area, a significant revisions has recently been approved which will significantly reduce conservatisms in seismic piping design as well as provide simplified design rules. Major revisions have also been made to the requirements for nuclear material manufacturers and suppliers, which should result in clearer understanding of this difficult administrative area of the code. In the area of Section XI inservice rules, substantial studies are underway to investigate the application of probabilistic, risked based inspection in lieu of the current deterministic inspection philosophy. While much work still is required in this area, it is an important potential application of the emerging field of risk based inspection

  16. NODC Standard Format Marine Toxic Substances and Pollutants (F144) chemical identification codes (NODC Accession 9200273)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival information package contains a listing of codes and chemical names that were used in NODC Standard Format Marine Toxic Substances and Pollutants (F144)...

  17. The status of Korean nuclear codes and standards

    International Nuclear Information System (INIS)

    Namha Kim; Jong-Hae Kim

    2005-01-01

    Korea Electric Power Industry Code (KEPIC), a set of integrated standards applicable to the design, construction and operation of electric power facilities including nuclear power plants, has been developed on the basis of referring to the prevailing U.S. codes and standards which had been applied to the electric power facilities in Korea. Being the developing and managing organization of KEPIC, Korea Electric Association (KEA) published its first edition in 1995, the second in 200,0 and is expected to publish the 2005 edition. KEPIC was applied to the construction of Ulchin Nuclear Units 5 and 6 in 1997, and will be applicable to the construction of forthcoming nuclear power plants in Korea. Along with the effectuation of the Agreement on Technical Barriers to Trade (TBT) in 1995, the international trend related to codes and standards is changing rapidly. The KEA is, therefore, making its utmost efforts so as for KEPIC to keep abreast with the changing environment in international arena. KEA notified ISO/IEC Information Centre of its acceptance of the Code of Good Practice in the Agreement on TBT. The 2005 KEPIC edition will be retrofitted according to the ISO/IEC Guide 21- Adoption of International Standards as regional or national standards. KEA's efforts will help KEPIC correspond with international standards such as ISO/IEC standards, and internationally recognized standards such as ASME codes and standards. (authors)

  18. Electrical, instrumentation, and control codes and standards

    International Nuclear Information System (INIS)

    Kranning, A.N.

    1978-01-01

    During recent years numerous documents in the form of codes and standards have been developed and published to provide design, fabrication and construction rules and criteria applicable to instrumentation, control and power distribution facilities for nuclear power plants. The contents of this LTR were prepared by NUS Corporation under Subcontract K5108 and provide a consolidated index and listing of the documents selected for their application to procurement of materials and design of modifications and new construction at the LOFT facility. These codes and standards should be applied together with the National Electrical Code, the ID Engineering Standards and LOFT Specifications to all LOFT instrument and electrical design activities

  19. Improved accuracy of co-morbidity coding over time after the introduction of ICD-10 administrative data.

    Science.gov (United States)

    Januel, Jean-Marie; Luthi, Jean-Christophe; Quan, Hude; Borst, François; Taffé, Patrick; Ghali, William A; Burnand, Bernard

    2011-08-18

    Co-morbidity information derived from administrative data needs to be validated to allow its regular use. We assessed evolution in the accuracy of coding for Charlson and Elixhauser co-morbidities at three time points over a 5-year period, following the introduction of the International Classification of Diseases, 10th Revision (ICD-10), coding of hospital discharges. Cross-sectional time trend evaluation study of coding accuracy using hospital chart data of 3'499 randomly selected patients who were discharged in 1999, 2001 and 2003, from two teaching and one non-teaching hospital in Switzerland. We measured sensitivity, positive predictive and Kappa values for agreement between administrative data coded with ICD-10 and chart data as the 'reference standard' for recording 36 co-morbidities. For the 17 the Charlson co-morbidities, the sensitivity - median (min-max) - was 36.5% (17.4-64.1) in 1999, 42.5% (22.2-64.6) in 2001 and 42.8% (8.4-75.6) in 2003. For the 29 Elixhauser co-morbidities, the sensitivity was 34.2% (1.9-64.1) in 1999, 38.6% (10.5-66.5) in 2001 and 41.6% (5.1-76.5) in 2003. Between 1999 and 2003, sensitivity estimates increased for 30 co-morbidities and decreased for 6 co-morbidities. The increase in sensitivities was statistically significant for six conditions and the decrease significant for one. Kappa values were increased for 29 co-morbidities and decreased for seven. Accuracy of administrative data in recording clinical conditions improved slightly between 1999 and 2003. These findings are of relevance to all jurisdictions introducing new coding systems, because they demonstrate a phenomenon of improved administrative data accuracy that may relate to a coding 'learning curve' with the new coding system.

  20. Final Technical Report: Hydrogen Codes and Standards Outreach

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Karen I.

    2007-05-12

    This project contributed significantly to the development of new codes and standards, both domestically and internationally. The NHA collaborated with codes and standards development organizations to identify technical areas of expertise that would be required to produce the codes and standards that industry and DOE felt were required to facilitate commercialization of hydrogen and fuel cell technologies and infrastructure. NHA staff participated directly in technical committees and working groups where issues could be discussed with the appropriate industry groups. In other cases, the NHA recommended specific industry experts to serve on technical committees and working groups where the need for this specific industry expertise would be on-going, and where this approach was likely to contribute to timely completion of the effort. The project also facilitated dialog between codes and standards development organizations, hydrogen and fuel cell experts, the government and national labs, researchers, code officials, industry associations, as well as the public regarding the timeframes for needed codes and standards, industry consensus on technical issues, procedures for implementing changes, and general principles of hydrogen safety. The project facilitated hands-on learning, as participants in several NHA workshops and technical meetings were able to experience hydrogen vehicles, witness hydrogen refueling demonstrations, see metal hydride storage cartridges in operation, and view other hydrogen energy products.

  1. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Science.gov (United States)

    2013-03-26

    ... Energy Conservation Code. International Existing Building Code. International Fire Code. International... Code. International Property Maintenance Code. International Residential Code. International Swimming Pool and Spa Code International Wildland-Urban Interface Code. International Zoning Code. ICC Standards...

  2. Introduction to Standardization Administration of China

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Brief Introduction of SAC Standardization Administration of the People's Republic of China (SAC) was established in April 2001 and authorized by the State Council to exercise administrative responsibilities by undertaking unified management, supervision and overall coordination of standardization works in China.

  3. La bonne administration en droit communautaire et le Code européen de bonne conduite administrative

    NARCIS (Netherlands)

    Mendes, J.

    2009-01-01

    The Code of Good Administrative Behaviour is an important source for understandingthe principle and concept of good administration in European administrative law, since itencompasses certain aspects that tend to be overlooked by the case law of the European Courts andEuropean law scholars.

  4. Review and comparison of WWER and LWR Codes and Standards

    International Nuclear Information System (INIS)

    Buckthorpe, D.; Tashkinov, A.; Brynda, J.; Davies, L.M.; Cueto-Felgeueroso, C.; Detroux, P.; Bieniussa, K.; Guinovart, J.

    2003-01-01

    The results of work on a collaborative project on comparison of Codes and Standards used for safety related components of the WWER and LWR type reactors is presented. This work was performed on behalf of the European Commission, Working Group Codes and Standards and considers areas such as rules, criteria and provisions, failure mechanisms , derivation and understanding behind the fatigue curves, piping, materials and aging, manufacturing and ISI. WWERs are essentially designed and constructed using the Russian PNAE Code together with special provisions in a few countries (e.g. Czech Republic) from national standards. The LWR Codes have a strong dependence on the ASME Code. Also within Western Europe other codes are used including RCC-M, KTA and British Standards. A comparison of procedures used in all these codes and standards have been made to investigate the potential for equivalencies between the codes and any grounds for future cooperation between eastern and western experts in this field. (author)

  5. C++ Coding Standards 101 Rules, Guidelines, and Best Practices

    CERN Document Server

    Sutter, Herb

    2005-01-01

    Consistent, high-quality coding standards improve software quality, reduce time-to-market, promote teamwork, eliminate time wasted on inconsequential matters, and simplify maintenance. Now, two of the world's most respected C++ experts distill the rich collective experience of the global C++ community into a set of coding standards that every developer and development team can understand and use as a basis for their own coding standards.

  6. Energy Efficiency Program Administrators and Building Energy Codes

    Science.gov (United States)

    Explore how energy efficiency program administrators have helped advance building energy codes at federal, state, and local levels—using technical, institutional, financial, and other resources—and discusses potential next steps.

  7. Building climate change into infrastructure codes and standards

    International Nuclear Information System (INIS)

    Auld, H.; Klaasen, J.; Morris, R.; Fernandez, S.; MacIver, D.; Bernstein, D.

    2009-01-01

    'Full text:' Building codes and standards and the climatic design values embedded within these legal to semi-legal documents have profound safety, health and economic implications for Canada's infrastructure systems. The climatic design values that have been used for the design of almost all of today's more than $5.5 Trillion in infrastructure are based on historical climate data and assume that the extremes of the past will represent future conditions. Since new infrastructure based on codes and standards will be built to survive for decades to come, it is critically important that existing climatic design information be as accurate and up-to-date as possible, that the changing climate be monitored to detect and highlight vulnerabilities of existing infrastructure, that forensic studies of climate-related failures be undertaken and that codes and standards processes incorporate future climates and extremes as much as possible. Uncertainties in the current climate change models and their scenarios currently challenge our ability to project future extremes regionally and locally. Improvements to the spatial and temporal resolution of these climate change scenarios, along with improved methodologies to treat model biases and localize results, will allow future codes and standards to better reflect the extremes and weathering conditions expected over the lifespan of structures. In the meantime, other information and code processes can be used to incorporate changing climate conditions into upcoming infrastructure codes and standards, to “bridge” the model uncertainty gap and to complement the state of existing projections. This presentation will outline some of the varied information and processes that will be used to incorporate climate change adaptation into the next development cycle of the National Building Code of Canada and numerous other national CSA infrastructure standards. (author)

  8. ASME nuclear codes and standards risk management strategic plan

    International Nuclear Information System (INIS)

    Balkey, Kenneth R.

    2003-01-01

    Over the past 15 years, several risk-informed initiatives have been completed or are under development within the ASME Nuclear Codes and Standards organization. In order to better manage the numerous initiatives in the future, the ASME Board on Nuclear Codes and Standards has recently developed and approved a Risk Management Strategic Plan. This paper presents the latest approved version of the plan beginning with a background of applications completed to date, including the recent issuance of the ASME Standard for Probabilistic Risk Assessment (PRA) for Nuclear Power Plant Applications. The paper discusses potential applications within ASME Nuclear Codes and Standards that may require expansion of the PRA Standard, such as for new generation reactors, or the development of new PRA Standards. A long-term vision for the potential development and evolution to a nuclear systems code that adopts a risk-informed approach across a facility life-cycle (design, construction, operation, maintenance, and closure) is summarized. Finally, near term and long term actions are defined across the ASME Nuclear Codes and Standards organizations related to risk management, and related U.S. regulatory activities are also summarized. (author)

  9. Validity of administrative database code algorithms to identify vascular access placement, surgical revisions, and secondary patency.

    Science.gov (United States)

    Al-Jaishi, Ahmed A; Moist, Louise M; Oliver, Matthew J; Nash, Danielle M; Fleet, Jamie L; Garg, Amit X; Lok, Charmaine E

    2018-03-01

    We assessed the validity of physician billing codes and hospital admission using International Classification of Diseases 10th revision codes to identify vascular access placement, secondary patency, and surgical revisions in administrative data. We included adults (≥18 years) with a vascular access placed between 1 April 2004 and 31 March 2013 at the University Health Network, Toronto. Our reference standard was a prospective vascular access database (VASPRO) that contains information on vascular access type and dates of placement, dates for failure, and any revisions. We used VASPRO to assess the validity of different administrative coding algorithms by calculating the sensitivity, specificity, and positive predictive values of vascular access events. The sensitivity (95% confidence interval) of the best performing algorithm to identify arteriovenous access placement was 86% (83%, 89%) and specificity was 92% (89%, 93%). The corresponding numbers to identify catheter insertion were 84% (82%, 86%) and 84% (80%, 87%), respectively. The sensitivity of the best performing coding algorithm to identify arteriovenous access surgical revisions was 81% (67%, 90%) and specificity was 89% (87%, 90%). The algorithm capturing arteriovenous access placement and catheter insertion had a positive predictive value greater than 90% and arteriovenous access surgical revisions had a positive predictive value of 20%. The duration of arteriovenous access secondary patency was on average 578 (553, 603) days in VASPRO and 555 (530, 580) days in administrative databases. Administrative data algorithms have fair to good operating characteristics to identify vascular access placement and arteriovenous access secondary patency. Low positive predictive values for surgical revisions algorithm suggest that administrative data should only be used to rule out the occurrence of an event.

  10. Reconciliation of international administrative coding systems for comparison of colorectal surgery outcome.

    Science.gov (United States)

    Munasinghe, A; Chang, D; Mamidanna, R; Middleton, S; Joy, M; Penninckx, F; Darzi, A; Livingston, E; Faiz, O

    2014-07-01

    Significant variation in colorectal surgery outcomes exists between different countries. Better understanding of the sources of variable outcomes using administrative data requires alignment of differing clinical coding systems. We aimed to map similar diagnoses and procedures across administrative coding systems used in different countries. Administrative data were collected in a central database as part of the Global Comparators (GC) Project. In order to unify these data, a systematic translation of diagnostic and procedural codes was undertaken. Codes for colorectal diagnoses, resections, operative complications and reoperative interventions were mapped across the respective national healthcare administrative coding systems. Discharge data from January 2006 to June 2011 for patients who had undergone colorectal surgical resections were analysed to generate risk-adjusted models for mortality, length of stay, readmissions and reoperations. In all, 52 544 case records were collated from 31 institutions in five countries. Mapping of all the coding systems was achieved so that diagnosis and procedures from the participant countries could be compared. Using the aligned coding systems to develop risk-adjusted models, the 30-day mortality rate for colorectal surgery was 3.95% (95% CI 0.86-7.54), the 30-day readmission rate was 11.05% (5.67-17.61), the 28-day reoperation rate was 6.13% (3.68-9.66) and the mean length of stay was 14 (7.65-46.76) days. The linkage of international hospital administrative data that we developed enabled comparison of documented surgical outcomes between countries. This methodology may facilitate international benchmarking. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  11. Running code as part of an open standards policy

    OpenAIRE

    Shah, Rajiv; Kesan, Jay

    2009-01-01

    Governments around the world are considering implementing or even mandating open standards policies. They believe these policies will provide economic, socio-political, and technical benefits. In this article, we analyze the failure of the Massachusetts’s open standards policy as applied to document formats. We argue it failed due to the lack of running code. Running code refers to multiple independent, interoperable implementations of an open standard. With running code, users have choice ...

  12. ASME nuclear codes and standards risk management strategic planning

    International Nuclear Information System (INIS)

    Hill, Ralph S. III; Balkey, Kenneth R.; Erler, Bryan A.; Wesley Rowley, C.

    2007-01-01

    This paper is prepared in honor and in memory of the late Professor Emeritus Yasuhide Asada to recognize his contributions to ASME Nuclear Codes and Standards initiatives, particularly those related to risk-informed technology and System Based Code developments. For nearly two decades, numerous risk-informed initiatives have been completed or are under development within the ASME Nuclear Codes and Standards organization. In order to properly manage the numerous initiatives currently underway or planned for the future, the ASME Board on Nuclear Codes and Standards (BNCS) has an established Risk Management Strategic Plan (Plan) that is maintained and updated by the ASME BNCS Risk Management Task Group. This paper presents the latest approved version of the plan beginning with a background of applications completed to date, including the recent probabilistic risk assessment (PRA) standards developments for nuclear power plant applications. The paper discusses planned applications within ASME Nuclear Codes and Standards that will require expansion of the ASME PRA Standard to support new advanced light water reactor and next generation reactor developments, such as for high temperature gas-cooled reactors. Emerging regulatory developments related to risk-informed, performance- based approaches are summarized. A long-term vision for the potential development and evolution to a nuclear systems code that adopts a risk-informed approach across a facility life-cycle (design, construction, operation, maintenance, and closure) is also summarized. Finally, near term and long term actions are defined across the ASME Nuclear Codes and Standards organizations related to risk management, including related U.S. regulatory activities. (author)

  13. Huffman coding in advanced audio coding standard

    Science.gov (United States)

    Brzuchalski, Grzegorz

    2012-05-01

    This article presents several hardware architectures of Advanced Audio Coding (AAC) Huffman noiseless encoder, its optimisations and working implementation. Much attention has been paid to optimise the demand of hardware resources especially memory size. The aim of design was to get as short binary stream as possible in this standard. The Huffman encoder with whole audio-video system has been implemented in FPGA devices.

  14. 18 CFR 410.1 - Basin regulations-Water Code and Administrative Manual-Part III Water Quality Regulations.

    Science.gov (United States)

    2010-04-01

    ... Code and Administrative Manual-Part III Water Quality Regulations. 410.1 Section 410.1 Conservation of... CODE AND ADMINISTRATIVE MANUAL-PART III WATER QUALITY REGULATIONS § 410.1 Basin regulations—Water Code and Administrative Manual—Part III Water Quality Regulations. (a) The Water Code of the Delaware River...

  15. ASME Section XI trends in developing nuclear codes and standards

    International Nuclear Information System (INIS)

    Hedden, O.F.

    1995-01-01

    When the author began working on nuclear power many years ago, he knew that perfection was the only acceptable technical standard. Unfortunately, this became an obsession with perfection that has had unfavorable consequences in some of the non-technical areas of work in ASME nuclear power Codes and Standards. However, the economic problems of the nuclear power industry now demand a more pragmatic approach if the industry is to continue. Not only does each item considered for action need to be evaluated to criteria that may in some cases be less than perfection, but one needs to consider whether it contributes tangibly to either safety or to reduction in technical or administrative burden. These should be the governing, criteria. The introduction of risk-based inspection methodologies will certainly be an important element in doing this successfully. One needs to consider these criteria collectively, as one discusses each item at the committee level, and individually, as one votes on each item. In the past, the author has been concerned that the industry was not acting quickly enough in taking advantage of opportunities offered by the Code to increase safety or to reduce cost. While he still has some concern, he thinks communication channels have been greatly improved. Now he is becoming more concerned with both the collective and individual actions that delay beneficial changes. The second part of the author's talk has to do with the relevance of the code committees in the nuclear power industry regulatory process

  16. Telemetry Standards, RCC Standard 106-17, Chapter 4, Pulse Code Modulation Standards

    Science.gov (United States)

    2017-07-01

    A-4 Appendix 4-B. Citations ...investigation can be found in a paper by J. L. Maury, Jr. and J. Styles , “Development of Optimum Frame Synchronization Codes for Goddard Space Flight Center...Standards, RCC Standard 106-17 Chapter 4, July 2017 B-1 APPENDIX 4-B Citations Aeronautical Radio, Inc. Mark 33 Digital Information Transfer

  17. Cross-index to DOE-prescribed occupational safety codes and standards

    International Nuclear Information System (INIS)

    1982-01-01

    A compilation of detailed information from more than three hundred and fifty DOE-prescribed or OSHA-referenced industrial safety codes and standards is presented. Condensed data from individual code portions are listed according to reference code, section, paragraph and page. A glossary of letter initials/abbreviations for the organizations or documents whose codes or standards are contained in this Cross-Index, is listed

  18. Boltzmann-Fokker-Planck calculations using standard discrete-ordinates codes

    International Nuclear Information System (INIS)

    Morel, J.E.

    1987-01-01

    The Boltzmann-Fokker-Planck (BFP) equation can be used to describe both neutral and charged-particle transport. Over the past several years, the author and several collaborators have developed methods for representing Fokker-Planck operators with standard multigroup-Legendre cross-section data. When these data are input to a standard S/sub n/ code such as ONETRAN, the code actually solves the Boltzmann-Fokker-Planck equation rather than the Boltzmann equation. This is achieved wihout any modification to the S/sub n/ codes. Because BFP calculations can be more demanding from a numerical viewpoint than standard neutronics calculations, we have found it useful to implement new quadrature methods ad convergence acceleration methods in the standard discrete-ordinates code, ONETRAN. We discuss our BFP cross-section representation techniques, our improved quadrature and acceleration techniques, and present results from BFP coupled electron-photon transport calculations performed with ONETRAN. 19 refs., 7 figs

  19. Codes and standards and other guidance cited in regulatory documents

    International Nuclear Information System (INIS)

    Nickolaus, J.R.; Bohlander, K.L.

    1996-08-01

    As part of the U.S. Nuclear Regulatory Commission (NRC) Standard Review Plan Update and Development Program (SRP-UDP), Pacific Northwest National Laboratory developed a listing of industry consensus codes and standards and other government and industry guidance referred to in regulatory documents. The SRP-UDP has been completed and the SRP-Maintenance Program (SRP-MP) is now maintaining this listing. Besides updating previous information, Revision 3 adds approximately 80 citations. This listing identifies the version of the code or standard cited in the regulatory document, the regulatory document, and the current version of the code or standard. It also provides a summary characterization of the nature of the citation. This listing was developed from electronic searches of the Code of Federal Regulations and the NRC's Bulletins, Information Notices, Circulars, Enforcement Manual, Generic Letters, Inspection Manual, Policy Statements, Regulatory Guides, Standard Technical Specifications and the Standard Review Plan (NUREG-0800)

  20. Codes and standards and other guidance cited in regulatory documents

    Energy Technology Data Exchange (ETDEWEB)

    Nickolaus, J.R.; Bohlander, K.L.

    1996-08-01

    As part of the U.S. Nuclear Regulatory Commission (NRC) Standard Review Plan Update and Development Program (SRP-UDP), Pacific Northwest National Laboratory developed a listing of industry consensus codes and standards and other government and industry guidance referred to in regulatory documents. The SRP-UDP has been completed and the SRP-Maintenance Program (SRP-MP) is now maintaining this listing. Besides updating previous information, Revision 3 adds approximately 80 citations. This listing identifies the version of the code or standard cited in the regulatory document, the regulatory document, and the current version of the code or standard. It also provides a summary characterization of the nature of the citation. This listing was developed from electronic searches of the Code of Federal Regulations and the NRC`s Bulletins, Information Notices, Circulars, Enforcement Manual, Generic Letters, Inspection Manual, Policy Statements, Regulatory Guides, Standard Technical Specifications and the Standard Review Plan (NUREG-0800).

  1. Rulemaking efforts on codes and standards

    International Nuclear Information System (INIS)

    Millman, G.C.

    1992-01-01

    Section 50.55a of the NRC regulations provides a mechanism for incorporating national codes and standards into the regulatory process. It incorporates by reference ASME Boiler and Pressure Vessel Code (ASME B and PV Code) Section 3 rules for construction and Section 11 rules for inservice inspection and inservice testing. The regulation is periodically amended to update these references. The rulemaking process, as applied to Section 50.55a amendments, is overviewed to familiarize users with associated internal activities of the NRC staff and the manner in which public comments are integrated into the process. The four ongoing rulemaking actions that would individually amend Section 50.55a are summarized. Two of the actions would directly impact requirements for inservice testing. Benefits accrued with NRC endorsement of the ASME B and PV Code, and possible future endorsement of the ASME Operations and Maintenance Code (ASME OM Code), are identified. Emphasis is placed on the need for code writing committees to be especially sensitive to user feedback on code rules incorporated into the regulatory process to ensure that the rules are complete, technically accurate, clear, practical, and enforceable

  2. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.

    Science.gov (United States)

    Weems, Shelley; Heller, Pamela; Fenton, Susan H

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.

  3. International Accreditation of ASME Codes and Standards

    International Nuclear Information System (INIS)

    Green, Mervin R.

    1989-01-01

    ASME established a Boiler Code Committee to develop rules for the design, fabrication and inspection of boilers. This year we recognize 75 years of that Code and will publish a history of that 75 years. The first Code and subsequent editions provided for a Code Symbol Stamp or mark which could be affixed by a manufacturer to a newly constructed product to certify that the manufacturer had designed, fabricated and had inspected it in accordance with Code requirements. The purpose of the ASME Mark is to identify those boilers that meet ASME Boiler and Pressure Vessel Code requirements. Through thousands of updates over the years, the Code has been revised to reflect technological advances and changing safety needs. Its scope has been broadened from boilers to include pressure vessels, nuclear components and systems. Proposed revisions to the Code are published for public review and comment four times per year and revisions and interpretations are published annually; it's a living and constantly evolving Code. You and your organizations are a vital part of the feedback system that keeps the Code alive. Because of this dynamic Code, we no longer have columns in newspapers listing boiler explosions. Nevertheless, it has been argued recently that ASME should go further in internationalizing its Code. Specifically, representatives of several countries, have suggested that ASME delegate to them responsibility for Code implementation within their national boundaries. The question is, thus, posed: Has the time come to franchise responsibility for administration of ASME's Code accreditation programs to foreign entities or, perhaps, 'institutes.' And if so, how should this be accomplished?

  4. Review of codes, standards, and regulations for natural gas locomotives.

    Science.gov (United States)

    2014-06-01

    This report identified, collected, and summarized relevant international codes, standards, and regulations with potential : applicability to the use of natural gas as a locomotive fuel. Few international or country-specific codes, standards, and regu...

  5. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  6. Quality assurance requirements in various codes and standards

    International Nuclear Information System (INIS)

    Shaaban, H.I.; EL-Sayed, A.; Aly, A.E.

    1987-01-01

    The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants

  7. Nasa-wide Standard Administrative Systems

    Science.gov (United States)

    Schneck, P.

    1984-01-01

    Factors to be considered in developing agency-wide standard administrative systems for NASA include uniformity of hardware and software; centralization vs. decentralization; risk exposure; and models for software development.

  8. A Domain Standard for Land Administration

    NARCIS (Netherlands)

    Lemmen, C.; Van Oosterom, P.; Van der Molen, P.

    2013-01-01

    This paper presents the design of a Domain Model for Land Administration (LA). As a result a formal International Standard is available: ISO 19152 Geographic Information – Land Administration Domain Model (LADM) (ISO, 2012). Domain specific standardisation is needed to capture the semantics of the

  9. Association Between Workarounds and Medication Administration Errors in Bar Code-Assisted Medication Administration : Protocol of a Multicenter Study

    NARCIS (Netherlands)

    van der Veen, Willem; van den Bemt, Patricia Mla; Bijlsma, Maarten; de Gier, Han J; Taxis, Katja

    2017-01-01

    BACKGROUND: Information technology-based methods such as bar code-assisted medication administration (BCMA) systems have the potential to reduce medication administration errors (MAEs) in hospitalized patients. In practice, however, systems are often not used as intended, leading to workarounds.

  10. Standard interface files and procedures for reactor physics codes. Version IV

    International Nuclear Information System (INIS)

    O'Dell, R.D.

    1977-09-01

    Standards, procedures, and recommendations of the Committee on Computer Code Coordination for promoting the exchange of reactor physics codes are updated to Version IV status. Standards and procedures covering general programming, program structure, standard interface files, and file management and handling subroutines are included

  11. CSA guide to Canadian wind turbine codes and standards

    International Nuclear Information System (INIS)

    2008-01-01

    The Canadian wind energy sector has become one of the fastest-growing wind energy markets in the world. Growth of the industry has been supported by various government agencies. However, many projects have experienced cost over-runs or cancellations as a result of unclear regulatory requirements, and wind energy developers are currently subject to a variety of approval processes involving several different authorities. This Canadian Standards Association (CSA) guide provided general information on codes and standards related to the design, approval, installation, operation, and maintenance of wind turbines in Canada. CSA codes and standards were developed by considering 5 new standards adopted by the International Electrotechnical Commission (IEC) Technical Committee on Wind Turbines. The standards described in this document related to acoustic noise measurement techniques; power performance measurements of electricity-producing wind turbines; lightning protection for wind turbine generator systems; design requirements for turbines; and design requirements for small wind turbines. The guide addressed specific subject areas related to the development of wind energy projects that involve formal or regulatory approval processes. Subject areas included issues related to safety, environmental design considerations, site selection, and mechanical systems. Information on associated standards and codes was also included

  12. Hydrogen Codes and Standards: An Overview of U.S. DOE Activities

    International Nuclear Information System (INIS)

    James M Ohi

    2006-01-01

    The Hydrogen, Fuel Cells, and Infrastructure Technologies (HFCIT) Program of the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL), with the help of leading standards and model code development organizations, other national laboratories, and key stakeholders, are developing a coordinated and collaborative government-industry effort to prepare, review, and promulgate hydrogen codes and standards needed to expedite hydrogen infrastructure development. The focus of this effort is to put in place a coordinated and comprehensive hydrogen codes and standards program at the national and international levels. This paper updates an overview of the U.S. program to facilitate and coordinate the development of hydrogen codes and standards that was presented by the author at WHEC 15. (authors)

  13. 29 CFR 1630.7 - Standards, criteria, or methods of administration.

    Science.gov (United States)

    2010-07-01

    ... Standards, criteria, or methods of administration. It is unlawful for a covered entity to use standards, criteria, or methods of administration, which are not job-related and consistent with business necessity... 29 Labor 4 2010-07-01 2010-07-01 false Standards, criteria, or methods of administration. 1630.7...

  14. Codes and standards and other guidance cited in regulatory documents. Revision 1

    International Nuclear Information System (INIS)

    Ankrum, A.; Nickolaus, J.; Vinther, R.; Maguire-Moffitt, N.; Hammer, J.; Sherfey, L.; Warner, R.

    1994-08-01

    As part of the US Nuclear Regulatory Commission (NRC) Standard Review Plan Update and Development Program, Pacific Northwest Laboratory developed a listing of industry consensus codes and standards and other government and industry guidance referred to in regulatory documents. In addition to updating previous information, Revision 1 adds citations from the NRC Inspection Manual and the Improved Standard Technical Specifications. This listing identifies the version of the code or standard cited in the regulatory document, the regulatory document, and the current version of the code or standard. It also provides a summary characterization of the nature of the citation. This listing was developed from electronic searches of the Code of Federal Regulations and the NRC's Bulletins, Information Notices, Circulars, Generic Letters, Policy Statements, Regulatory Guides, and the Standard Review Plan (NUREG-0800)

  15. Codes and standards and other guidance cited in regulatory documents. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Ankrum, A.; Nickolaus, J.; Vinther, R.; Maguire-Moffitt, N.; Hammer, J.; Sherfey, L.; Warner, R. [Pacific Northwest Lab., Richland, WA (United States)

    1994-08-01

    As part of the US Nuclear Regulatory Commission (NRC) Standard Review Plan Update and Development Program, Pacific Northwest Laboratory developed a listing of industry consensus codes and standards and other government and industry guidance referred to in regulatory documents. In addition to updating previous information, Revision 1 adds citations from the NRC Inspection Manual and the Improved Standard Technical Specifications. This listing identifies the version of the code or standard cited in the regulatory document, the regulatory document, and the current version of the code or standard. It also provides a summary characterization of the nature of the citation. This listing was developed from electronic searches of the Code of Federal Regulations and the NRC`s Bulletins, Information Notices, Circulars, Generic Letters, Policy Statements, Regulatory Guides, and the Standard Review Plan (NUREG-0800).

  16. Standardization of computer programs - basis of the Czechoslovak library of nuclear codes

    International Nuclear Information System (INIS)

    Gregor, M.

    1987-01-01

    A standardized form of computer code documentation has been established in the CSSR in the field of reactor safety. Structure and content of the documentation are described and codes already subject to this process are mentioned. The formation of a Czechoslovak nuclear code library and facilitated discussion of safety reports containing results of standardized codes are aimed at

  17. 1995 building energy codes and standards workshops: Summary and documentation

    Energy Technology Data Exchange (ETDEWEB)

    Sandahl, L.J.; Shankle, D.L.

    1996-02-01

    During the spring of 1995, Pacific Northwest National Laboratory (PNNL) conducted four two-day Regional Building Energy Codes and Standards workshops across the US. Workshops were held in Chicago, Denver, Rhode Island, and Atlanta. The workshops were designed to benefit state-level officials including staff of building code commissions, energy offices, public utility commissions, and others involved with adopting/updating, implementing, and enforcing building energy codes in their states. The workshops provided an opportunity for state and other officials to learn more about residential and commercial building energy codes and standards, the role of the US Department of Energy and the Building Standards and Guidelines Program at Pacific Northwest National Laboratory, Home Energy Rating Systems (HERS), Energy Efficient Mortgages (EEM), training issues, and other topics related to the development, adoption, implementation, and enforcement of building energy codes. Participants heard success stories, got tips on enforcement training, and received technical support materials. In addition to receiving information on the above topics, workshop participants had an opportunity to provide input on code adoption issues, building industry training issues, building design issues, and exemplary programs across the US. This paper documents the workshop planning, findings, and follow-up processes.

  18. Lightening protection, techniques, applied codes and standards. Vol. 4

    International Nuclear Information System (INIS)

    Mahmoud, M.; Shaaban, H.; Lamey, S.

    1996-01-01

    Lightening is the only natural disaster that protection against is highly effective. Therefore for the safety of critical installations specifically nuclear, an effective lightening protection system (LPS) is required. The design and installation of LPS's have been addressed by many international codes and standards. In this paper, the various LPS's are discussed and compared, including radioactive air terminals, ionizing air terminals, and terminals equipped with electrical trigging devices. Also, the so-called dissipation array systems are discussed and compared to other systems technically and economically. Moreover, the available international codes and standards related to the lightening protection are discussed. such standards include those published by the national fire protection association (NFPA), lightening protection institute (LPI), underwriters laboratories (UL), and british standards Finally, the possibility of developing an egyptian national standards is discussed

  19. Codes, standards, and requirements for DOE facilities: natural phenomena design

    International Nuclear Information System (INIS)

    Webb, A.B.

    1985-01-01

    The basic requirements for codes, standards, and requirements are found in DOE Orders 5480.1A, 5480.4, and 6430.1. The type of DOE facility to be built and the hazards which it presents will determine the criteria to be applied for natural phenomena design. Mandatory criteria are established in the DOE orders for certain designs but more often recommended guidance is given. National codes and standards form a great body of experience from which the project engineer may draw. Examples of three kinds of facilities and the applicable codes and standards are discussed. The safety program planning approach to project management used at Westinghouse Hanford is outlined. 5 figures, 2 tables

  20. Training program for energy conservation in new building construction. Volume III. Energy conservation technology for plan examiners and code administrators. Energy Conservation Technology Series 200

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    Under the sponsorship of the United States Department of Energy, a Model Code for Energy Conservation in New Building Construction has been developed by those national organizations primarily concerned with the development and promulgation of model codes. The technical provisions are based on ASHRAE Standard 90-75 and are intended for use by state and local officials. The subject of regulation of new building construction to assure energy conservation is recognized as one in which code officials have not had previous exposure. It was also determined that application of the model code would be made at varying levels by officials with both a specific requirement for knowledge and a differing degree of prior training in the state-of-the-art. Therefore, a training program and instructional materials were developed for code officials to assist them in the implementation and enforcement of energy efficient standards and codes. The training program for Energy Conservation Tehnology for Plan Examiners and Code Administrators (ECT Series 200) is presented.

  1. China Dimensions Data Collection: GuoBiao (GB) Codes for the Administrative Divisions of the Peoples Republic of China

    Data.gov (United States)

    National Aeronautics and Space Administration — GuoBiao (GB) Codes for the Administrative Divisions of the People's Republic of China consists of geographic codes for the administrative divisions of China. The...

  2. Accuracy of ICD-10 Coding System for Identifying Comorbidities and Infectious Conditions Using Data from a Thai University Hospital Administrative Database.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Wongkamhla, Thanyarak; Thamlikitkul, Visanu

    2016-04-01

    To determine the accuracy of International Statistical Classification of Disease and Related Health Problems, 10th Revision (ICD-10) coding system in identifying comorbidities and infectious conditions using data from a Thai university hospital administrative database. A retrospective cross-sectional study was conducted among patients hospitalized in six general medicine wards at Siriraj Hospital. ICD-10 code data was identified and retrieved directly from the hospital administrative database. Patient comorbidities were captured using the ICD-10 coding algorithm for the Charlson comorbidity index. Infectious conditions were captured using the groups of ICD-10 diagnostic codes that were carefully prepared by two independent infectious disease specialists. Accuracy of ICD-10 codes combined with microbiological dataf or diagnosis of urinary tract infection (UTI) and bloodstream infection (BSI) was evaluated. Clinical data gathered from chart review was considered the gold standard in this study. Between February 1 and May 31, 2013, a chart review of 546 hospitalization records was conducted. The mean age of hospitalized patients was 62.8 ± 17.8 years and 65.9% of patients were female. Median length of stay [range] was 10.0 [1.0-353.0] days and hospital mortality was 21.8%. Conditions with ICD-10 codes that had good sensitivity (90% or higher) were diabetes mellitus and HIV infection. Conditions with ICD-10 codes that had good specificity (90% or higher) were cerebrovascular disease, chronic lung disease, diabetes mellitus, cancer HIV infection, and all infectious conditions. By combining ICD-10 codes with microbiological results, sensitivity increased from 49.5 to 66%for UTI and from 78.3 to 92.8%for BS. The ICD-10 coding algorithm is reliable only in some selected conditions, including underlying diabetes mellitus and HIV infection. Combining microbiological results with ICD-10 codes increased sensitivity of ICD-10 codes for identifying BSI. Future research is

  3. 76 FR 22383 - National Fire Codes: Request for Proposals for Revision of Codes and Standards

    Science.gov (United States)

    2011-04-21

    ... Chemical Extinguishing Systems. NFPA 22-2008 Standard for Water 5/23/2011 Tanks for Private Fire Protection... Ensembles for Technical Rescue Incidents. NFPA 1925-2008 Standard on Marine Fire- 5/23/2011 Fighting Vessels... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request...

  4. Using Administrative Mental Health Indicators in Heart Failure Outcomes Research: Comparison of Clinical Records and International Classification of Disease Coding.

    Science.gov (United States)

    Bender, Miriam; Smith, Tyler C

    2016-01-01

    Use of mental indication in health outcomes research is of growing interest to researchers. This study, as part of a larger research program, quantified agreement between administrative International Classification of Disease (ICD-9) coding for, and "gold standard" clinician documentation of, mental health issues (MHIs) in hospitalized heart failure (HF) patients to determine the validity of mental health administrative data for use in HF outcomes research. A 13% random sample (n = 504) was selected from all unique patients (n = 3,769) hospitalized with a primary HF diagnosis at 4 San Diego County community hospitals during 2009-2012. MHI was defined as ICD-9 discharge diagnostic coding 290-319. Records were audited for clinician documentation of MHI. A total of 43% (n = 216) had mental health clinician documentation; 33% (n = 164) had ICD-9 coding for MHI. ICD-9 code bundle 290-319 had 0.70 sensitivity, 0.97 specificity, and kappa 0.69 (95% confidence interval 0.61-0.79). More specific ICD-9 MHI code bundles had kappas ranging from 0.44 to 0.82 and sensitivities ranging from 42% to 82%. Agreement between ICD-9 coding and clinician documentation for a broadly defined MHI is substantial, and can validly "rule in" MHI for hospitalized patients with heart failure. More specific MHI code bundles had fair to almost perfect agreement, with a wide range of sensitivities for identifying patients with an MHI. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Globalization of ASME Nuclear Codes and Standards

    International Nuclear Information System (INIS)

    Swayne, Rick; Erler, Bryan A.

    2006-01-01

    With the globalization of the nuclear industry, it is clear that the reactor suppliers are based in many countries around the world (such as United States, France, Japan, Canada, South Korea, South Africa) and they will be marketing their reactors to many countries around the world (such as US, China, South Korea, France, Canada, Finland, Taiwan). They will also be fabricating their components in many different countries around the world. With this situation, it is clear that the requirements of ASME Nuclear Codes and Standards need to be adjusted to accommodate the regulations, fabricating processes, and technology of various countries around the world. It is also very important for the American Society of Mechanical Engineers (ASME) to be able to assure that products meeting the applicable ASME Code requirements will provide the same level of safety and quality assurance as those products currently fabricated under the ASME accreditation process. To do this, many countries are in the process of establishing or changing their regulations, and it is important for ASME to interface with the appropriate organizations in those countries, in order to ensure there is effective use of ASME Codes and standards around the world. (authors)

  6. 77 FR 67340 - National Fire Codes: Request for Comments on NFPA's Codes and Standards

    Science.gov (United States)

    2012-11-09

    ... Water Mist Fire P Protection Systems. NFPA 921 Guide for Fire and Explosion P Investigations. NFPA 1005 Standard for Professional P Qualifications for Marine Fire Fighting for Land-Based Fire Fighters. NFPA 1192... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request...

  7. 77 FR 64837 - Federal Aviation Administration

    Science.gov (United States)

    2012-10-23

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Fourth Meeting: RTCA Special Committee 227, Standards of Navigation Performance AGENCY: Federal Aviation Administration (FAA), U.S... Operations Group, Federal Aviation Administration. [FR Doc. 2012-26034 Filed 10-22-12; 8:45 am] BILLING CODE...

  8. The Impact of Bar Code Medication Administration Technology on Reported Medication Errors

    Science.gov (United States)

    Holecek, Andrea

    2011-01-01

    The use of bar-code medication administration technology is on the rise in acute care facilities in the United States. The technology is purported to decrease medication errors that occur at the point of administration. How significantly this technology affects actual rate and severity of error is unknown. This descriptive, longitudinal research…

  9. Data Representation, Coding, and Communication Standards.

    Science.gov (United States)

    Amin, Milon; Dhir, Rajiv

    2015-06-01

    The immense volume of cases signed out by surgical pathologists on a daily basis gives little time to think about exactly how data are stored. An understanding of the basics of data representation has implications that affect a pathologist's daily practice. This article covers the basics of data representation and its importance in the design of electronic medical record systems. Coding in surgical pathology is also discussed. Finally, a summary of communication standards in surgical pathology is presented, including suggested resources that establish standards for select aspects of pathology reporting. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. 48 CFR 52.230-6 - Administration of Cost Accounting Standards.

    Science.gov (United States)

    2010-10-01

    ... Clauses 52.230-6 Administration of Cost Accounting Standards. As prescribed in 30.201-4(d)(1), insert the following clause: Administration of Cost Accounting Standards (JUN 2010) For the purpose of administering the Cost Accounting Standards (CAS) requirements under this contract, the Contractor shall take the...

  11. Vehicle Codes and Standards: Overview and Gap Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blake, C.; Buttner, W.; Rivkin, C.

    2010-02-01

    This report identifies gaps in vehicle codes and standards and recommends ways to fill the gaps, focusing on six alternative fuels: biodiesel, natural gas, electricity, ethanol, hydrogen, and propane.

  12. NODC Standard Product: NODC Taxonomic Code on CD-ROM (NODC Accession 0050418)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The content of the NODC Taxonomic Code, Version 8 CD-ROM (CD-ROM NODC-68) distributed by NODC is archived in this accession. Version 7 of the NODC Taxonomic Code...

  13. Safety, codes and standards for hydrogen installations. Metrics development and benchmarking

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Aaron P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dedrick, Daniel E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Angela Christine [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); San Marchi, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-04-01

    Automakers and fuel providers have made public commitments to commercialize light duty fuel cell electric vehicles and fueling infrastructure in select US regions beginning in 2014. The development, implementation, and advancement of meaningful codes and standards is critical to enable the effective deployment of clean and efficient fuel cell and hydrogen solutions in the energy technology marketplace. Metrics pertaining to the development and implementation of safety knowledge, codes, and standards are important to communicate progress and inform future R&D investments. This document describes the development and benchmarking of metrics specific to the development of hydrogen specific codes relevant for hydrogen refueling stations. These metrics will be most useful as the hydrogen fuel market transitions from pre-commercial to early-commercial phases. The target regions in California will serve as benchmarking case studies to quantify the success of past investments in research and development supporting safety codes and standards R&D.

  14. Analyses to support development of risk-informed separation distances for hydrogen codes and standards.

    Energy Technology Data Exchange (ETDEWEB)

    LaChance, Jeffrey L.; Houf, William G. (Sandia National Laboratories, Livermore, CA); Fluer, Inc., Paso Robels, CA; Fluer, Larry (Fluer, Inc., Paso Robels, CA); Middleton, Bobby

    2009-03-01

    The development of a set of safety codes and standards for hydrogen facilities is necessary to ensure they are designed and operated safely. To help ensure that a hydrogen facility meets an acceptable level of risk, code and standard development organizations are tilizing risk-informed concepts in developing hydrogen codes and standards.

  15. 77 FR 69441 - Federal Acquisition Regulation; Information Collection; Cost Accounting Standards Administration

    Science.gov (United States)

    2012-11-19

    ...; Information Collection; Cost Accounting Standards Administration AGENCY: Department of Defense (DOD), General... collection requirement concerning cost accounting standards administration. Public comments are particularly... Information Collection 9000- 0129, Cost Accounting Standards Administration by any of the following methods...

  16. Improved entropy encoding for high efficient video coding standard

    Directory of Open Access Journals (Sweden)

    B.S. Sunil Kumar

    2018-03-01

    Full Text Available The High Efficiency Video Coding (HEVC has better coding efficiency, but the encoding performance has to be improved to meet the growing multimedia applications. This paper improves the standard entropy encoding by introducing the optimized weighing parameters, so that higher rate of compression can be accomplished over the standard entropy encoding. The optimization is performed using the recently introduced firefly algorithm. The experimentation is carried out using eight benchmark video sequences and the PSNR for varying rate of data transmission is investigated. Comparative analysis based on the performance statistics is made with the standard entropy encoding. From the obtained results, it is clear that the originality of the decoded video sequence is preserved far better than the proposed method, though the compression rate is increased. Keywords: Entropy, Encoding, HEVC, PSNR, Compression

  17. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    Science.gov (United States)

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  18. Development of standards, codes of practice and guidelines at the national level

    International Nuclear Information System (INIS)

    Swindon, T.N.

    1989-01-01

    Standards, codes of practice and guidelines are defined and their different roles in radiation protection specified. The work of the major bodies that develop such documents in Australia - the National Health and Medical Research Council and the Standards Association of Australia - is discussed. The codes of practice prepared under the Environment Protection (Nuclear Codes) Act, 1978, an act of the Australian Federal Parliament, are described and the guidelines associated with them outlined. 5 refs

  19. Cross-index to DOE-prescribed occupational safety codes and standards

    International Nuclear Information System (INIS)

    1981-01-01

    This Cross-Index volume is the 1981 compilation of detailed information from more than three hundred and fifty DOE prescribed or OSHA referenced industrial safety codes and standards and is revised yearly to provide information from current codes. Condensed data from individual code portions are listed according to reference code, section, paragraph and page. Each code is given a two-digit reference code number or letter in the Contents section (pages C to L) of this volume. This reference code provides ready identification of any code listed in the Cross-Index. The computerized information listings are on the left-hand portion of Cross-Index page; in order to the right of the listing are the reference code letters or numbers, the section, paragraph and page of the referenced code containing expanded information on the individual listing

  20. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    Science.gov (United States)

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  1. Land administration domain model is an ISO standard now

    NARCIS (Netherlands)

    Lemmen, Christiaan; van Oosterom, Peter; Uitermark, Harry; de Zeeuw, Kees

    2013-01-01

    A group of land administration professionals initiated the development of a data model that facilitates the quick and efficient set-up of land registrations. Just like social issues benefit from proper land administration, land administration systems themselves benefit from proper data standards. In

  2. 3D video coding: an overview of present and upcoming standards

    Science.gov (United States)

    Merkle, Philipp; Müller, Karsten; Wiegand, Thomas

    2010-07-01

    An overview of existing and upcoming 3D video coding standards is given. Various different 3D video formats are available, each with individual pros and cons. The 3D video formats can be separated into two classes: video-only formats (such as stereo and multiview video) and depth-enhanced formats (such as video plus depth and multiview video plus depth). Since all these formats exist of at least two video sequences and possibly additional depth data, efficient compression is essential for the success of 3D video applications and technologies. For the video-only formats the H.264 family of coding standards already provides efficient and widely established compression algorithms: H.264/AVC simulcast, H.264/AVC stereo SEI message, and H.264/MVC. For the depth-enhanced formats standardized coding algorithms are currently being developed. New and specially adapted coding approaches are necessary, as the depth or disparity information included in these formats has significantly different characteristics than video and is not displayed directly, but used for rendering. Motivated by evolving market needs, MPEG has started an activity to develop a generic 3D video standard within the 3DVC ad-hoc group. Key features of the standard are efficient and flexible compression of depth-enhanced 3D video representations and decoupling of content creation and display requirements.

  3. Discrete-ordinates electron transport calculations using standard neutron transport codes

    International Nuclear Information System (INIS)

    Morel, J.E.

    1979-01-01

    The primary purpose of this work was to develop a method for using standard neutron transport codes to perform electron transport calculations. The method is to develop approximate electron cross sections which are sufficiently well-behaved to be treated with standard S/sub n/ methods, but which nonetheless yield flux solutions which are very similar to the exact solutions. The main advantage of this approach is that, once the approximate cross sections are constructed, their multigroup Legendre expansion coefficients can be calculated and input to any standard S/sub n/ code. Discrete-ordinates calculations were performed to determine the accuracy of the flux solutions for problems corresponding to 1.0-MeV electrons incident upon slabs of aluminum and gold. All S/sub n/ calculations were compared with similar calculations performed with an electron Monte Carlo code, considered to be exact. In all cases, the discrete-ordinates solutions for integral flux quantities (i.e., scalar flux, energy deposition profiles, etc.) are generally in agreement with the Monte Carlo solutions to within approximately 5% or less. The central conclusion is that integral electron flux quantities can be efficiently and accurately calculated using standard S/sub n/ codes in conjunction with approximate cross sections. Furthermore, if group structures and approximate cross section construction are optimized, accurate differential flux energy spectra may also be obtainable without having to use an inordinately large number of energy groups. 1 figure

  4. Comparison of codes and standards for radiographic inspection

    International Nuclear Information System (INIS)

    Bingoeldag, M. M.; Aksu, M.; Akguen, A. F.

    1995-01-01

    This report compares the procedurel requirements and acceptance criteria for radiographic inspections specified in the relevant national and international codes and standards. In particular, detailed analysis of inspection conditions such as exposure arrangements, and contrast requirements are given

  5. Future direction of ASME nuclear codes and standards

    International Nuclear Information System (INIS)

    Ennis, Kevin; Sheehan, Mark E.

    2003-01-01

    While the nuclear power industry in the US is in a period of stasis, there continues to be a great deal of activity in the ASME nuclear standards development arena. As plants age, the need for new approaches in standardization changes with the changing needs of the industry. New tools are becoming available in the form of risk analysis, and this is finding its way into more and more of ASME's standards activities. This paper will take a look at the direction that ASME nuclear Codes and Standards are heading in this and other areas, as well as taking a look at some advance reactor concepts and plans for standards to address new technologies

  6. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data

    Science.gov (United States)

    Jolley, Rachel J; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-01-01

    Objective Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. Setting and participants All adults (aged ≥18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Research design Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Measures Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. Conclusions This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. PMID:26700284

  7. Effect of change in coding rules on recording diabetes in hospital administrative datasets.

    Science.gov (United States)

    Assareh, Hassan; Achat, Helen M; Guevarra, Veth M; Stubbs, Joanne M

    2016-10-01

    During 2008-2011 Australian Coding Standards mandated a causal relationship between diabetes and inpatient care as a criterion for recording diabetes as a comorbidity in hospital administrative datasets. We aim to measure the effect of the causality mandate on recorded diabetes and associated inter-hospital variations. For patients with diabetes, all admissions between 2004 and 2013 to all New South Wales acute public hospitals were investigated. Poisson mixed models were employed to derive adjusted rates and variations. The non-recorded diabetes incidence rate was 20.7%. The causality mandate increased the incidence rate four fold during the change period, 2008-2011, compared to the pre- or post-change periods (32.5% vs 8.4% and 6.9%). The inter-hospital variation was also higher, with twice the difference in the non-recorded rate between hospitals with the highest and lowest rates (50% vs 24% and 27% risk gap). The variation decreased during the change period (29%), while the rate continued to rise (53%). Admission characteristics accounted for over 44% of the variation compared with at most two per cent attributable to patient or hospital characteristics. Contributing characteristics explained less of the variation within the change period compared to pre- or post-change (46% vs 58% and 53%). Hospital relative performance was not constant over time. The causality mandate substantially increased the non-recorded diabetes rate and associated inter-hospital variation. Longitudinal accumulation of clinical information at the patient level, and the development of appropriate adoption protocols to achieve comprehensive and timely implementation of coding changes are essential to supporting the integrity of hospital administrative datasets. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Cardiac arrest risk standardization using administrative data compared to registry data.

    Directory of Open Access Journals (Sweden)

    Anne V Grossestreuer

    Full Text Available Methods for comparing hospitals regarding cardiac arrest (CA outcomes, vital for improving resuscitation performance, rely on data collected by cardiac arrest registries. However, most CA patients are treated at hospitals that do not participate in such registries. This study aimed to determine whether CA risk standardization modeling based on administrative data could perform as well as that based on registry data.Two risk standardization logistic regression models were developed using 2453 patients treated from 2000-2015 at three hospitals in an academic health system. Registry and administrative data were accessed for all patients. The outcome was death at hospital discharge. The registry model was considered the "gold standard" with which to compare the administrative model, using metrics including comparing areas under the curve, calibration curves, and Bland-Altman plots. The administrative risk standardization model had a c-statistic of 0.891 (95% CI: 0.876-0.905 compared to a registry c-statistic of 0.907 (95% CI: 0.895-0.919. When limited to only non-modifiable factors, the administrative model had a c-statistic of 0.818 (95% CI: 0.799-0.838 compared to a registry c-statistic of 0.810 (95% CI: 0.788-0.831. All models were well-calibrated. There was no significant difference between c-statistics of the models, providing evidence that valid risk standardization can be performed using administrative data.Risk standardization using administrative data performs comparably to standardization using registry data. This methodology represents a new tool that can enable opportunities to compare hospital performance in specific hospital systems or across the entire US in terms of survival after CA.

  9. Canadian energy standards : residential energy code requirements

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, K. [SAR Engineering Ltd., Burnaby, BC (Canada)

    2006-09-15

    A survey of residential energy code requirements was discussed. New housing is approximately 13 per cent more efficient than housing built 15 years ago, and more stringent energy efficiency requirements in building codes have contributed to decreased energy use and greenhouse gas (GHG) emissions. However, a survey of residential energy codes across Canada has determined that explicit demands for energy efficiency are currently only present in British Columbia (BC), Manitoba, Ontario and Quebec. The survey evaluated more than 4300 single-detached homes built between 2000 and 2005 using data from the EnerGuide for Houses (EGH) database. House area, volume, airtightness and construction characteristics were reviewed to create archetypes for 8 geographic areas. The survey indicated that in Quebec and the Maritimes, 90 per cent of houses comply with ventilation system requirements of the National Building Code, while compliance in the rest of Canada is much lower. Heat recovery ventilation use is predominant in the Atlantic provinces. Direct-vent or condensing furnaces constitute the majority of installed systems in provinces where natural gas is the primary space heating fuel. Details of Insulation levels for walls, double-glazed windows, and building code insulation standards were also reviewed. It was concluded that if R-2000 levels of energy efficiency were applied, total average energy consumption would be reduced by 36 per cent in Canada. 2 tabs.

  10. 2016 Updated American Society of Clinical Oncology/Oncology Nursing Society Chemotherapy Administration Safety Standards, Including Standards for Pediatric Oncology.

    Science.gov (United States)

    Neuss, Michael N; Gilmore, Terry R; Belderson, Kristin M; Billett, Amy L; Conti-Kalchik, Tara; Harvey, Brittany E; Hendricks, Carolyn; LeFebvre, Kristine B; Mangu, Pamela B; McNiff, Kristen; Olsen, MiKaela; Schulmeister, Lisa; Von Gehr, Ann; Polovich, Martha

    2016-12-01

    Purpose To update the ASCO/Oncology Nursing Society (ONS) Chemotherapy Administration Safety Standards and to highlight standards for pediatric oncology. Methods The ASCO/ONS Chemotherapy Administration Safety Standards were first published in 2009 and updated in 2011 to include inpatient settings. A subsequent 2013 revision expanded the standards to include the safe administration and management of oral chemotherapy. A joint ASCO/ONS workshop with stakeholder participation, including that of the Association of Pediatric Hematology Oncology Nurses and American Society of Pediatric Hematology/Oncology, was held on May 12, 2015, to review the 2013 standards. An extensive literature search was subsequently conducted, and public comments on the revised draft standards were solicited. Results The updated 2016 standards presented here include clarification and expansion of existing standards to include pediatric oncology and to introduce new standards: most notably, two-person verification of chemotherapy preparation processes, administration of vinca alkaloids via minibags in facilities in which intrathecal medications are administered, and labeling of medications dispensed from the health care setting to be taken by the patient at home. The standards were reordered and renumbered to align with the sequential processes of chemotherapy prescription, preparation, and administration. Several standards were separated into their respective components for clarity and to facilitate measurement of adherence to a standard. Conclusion As oncology practice has changed, so have chemotherapy administration safety standards. Advances in technology, cancer treatment, and education and training have prompted the need for periodic review and revision of the standards. Additional information is available at http://www.asco.org/chemo-standards .

  11. Coding of obesity in administrative hospital discharge abstract data: accuracy and impact for future research studies.

    Science.gov (United States)

    Martin, Billie-Jean; Chen, Guanmin; Graham, Michelle; Quan, Hude

    2014-02-13

    Obesity is a pervasive problem and a popular subject of academic assessment. The ability to take advantage of existing data, such as administrative databases, to study obesity is appealing. The objective of our study was to assess the validity of obesity coding in an administrative database and compare the association between obesity and outcomes in an administrative database versus registry. This study was conducted using a coronary catheterization registry and an administrative database (Discharge Abstract Database (DAD)). A Body Mass Index (BMI) ≥30 kg/m2 within the registry defined obesity. In the DAD obesity was defined by diagnosis codes E65-E68 (ICD-10). The sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of an obesity diagnosis in the DAD was determined using obesity diagnosis in the registry as the referent. The association between obesity and outcomes was assessed. The study population of 17380 subjects was largely male (68.8%) with a mean BMI of 27.0 kg/m2. Obesity prevalence was lower in the DAD than registry (2.4% vs. 20.3%). A diagnosis of obesity in the DAD had a sensitivity 7.75%, specificity 98.98%, NPV 80.84% and PPV 65.94%. Obesity was associated with decreased risk of death or re-hospitalization, though non-significantly within the DAD. Obesity was significantly associated with an increased risk of cardiac procedure in both databases. Overall, obesity was poorly coded in the DAD. However, when coded, it was coded accurately. Administrative databases are not an optimal datasource for obesity prevalence and incidence surveillance but could be used to define obese cohorts for follow-up.

  12. Up to code: does your company's conduct meet world-class standards?

    Science.gov (United States)

    Paine, Lynn; Deshpandé, Rohit; Margolis, Joshua D; Bettcher, Kim Eric

    2005-12-01

    Codes of conduct have long been a feature of corporate life. Today, they are arguably a legal necessity--at least for public companies with a presence in the United States. But the issue goes beyond U.S. legal and regulatory requirements. Sparked by corruption and excess of various types, dozens of industry, government, investor, and multisector groups worldwide have proposed codes and guidelines to govern corporate behavior. These initiatives reflect an increasingly global debate on the nature of corporate legitimacy. Given the legal, organizational, reputational, and strategic considerations, few companies will want to be without a code. But what should it say? Apart from a handful of essentials spelled out in Sarbanes-Oxley regulations and NYSE rules, authoritative guidance is sorely lacking. In search of some reference points for managers, the authors undertook a systematic analysis of a select group of codes. In this article, they present their findings in the form of a "codex," a reference source on code content. The Global Business Standards Codex contains a set of overarching principles as well as a set of conduct standards for putting those principles into practice. The GBS Codex is not intended to be adopted as is, but is meant to be used as a benchmark by those wishing to create their own world-class code. The provisions of the codex must be customized to a company's specific business and situation; individual companies' codes will include their own distinctive elements as well. What the codex provides is a starting point grounded in ethical fundamentals and aligned with an emerging global consensus on basic standards of corporate behavior.

  13. 1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...

  14. Final Report. An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, Andrew [New Mexico State Univ., Las Cruces, NM (United States)

    2013-12-30

    The DOE grant, “An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group,” to New Mexico State University created the Solar America Board for Codes and Standards (Solar ABCs). From 2007 – 2013 with funding from this grant, Solar ABCs identified current issues, established a dialogue among key stakeholders, and catalyzed appropriate activities to support the development of codes and standards that facilitated the installation of high quality, safe photovoltaic systems. Solar ABCs brought the following resources to the PV stakeholder community; Formal coordination in the planning or revision of interrelated codes and standards removing “stove pipes” that have only roofing experts working on roofing codes, PV experts on PV codes, fire enforcement experts working on fire codes, etc.; A conduit through which all interested stakeholders were able to see the steps being taken in the development or modification of codes and standards and participate directly in the processes; A central clearing house for new documents, standards, proposed standards, analytical studies, and recommendations of best practices available to the PV community; A forum of experts that invites and welcomes all interested parties into the process of performing studies, evaluating results, and building consensus on standards and code-related topics that affect all aspects of the market; and A biennial gap analysis to formally survey the PV community to identify needs that are unmet and inhibiting the market and necessary technical developments.

  15. Minimizing human error in radiopharmaceutical preparation and administration via a bar code-enhanced nuclear pharmacy management system.

    Science.gov (United States)

    Hakala, John L; Hung, Joseph C; Mosman, Elton A

    2012-09-01

    The objective of this project was to ensure correct radiopharmaceutical administration through the use of a bar code system that links patient and drug profiles with on-site information management systems. This new combined system would minimize the amount of manual human manipulation, which has proven to be a primary source of error. The most common reason for dosing errors is improper patient identification when a dose is obtained from the nuclear pharmacy or when a dose is administered. A standardized electronic transfer of information from radiopharmaceutical preparation to injection will further reduce the risk of misadministration. Value stream maps showing the flow of the patient dose information, as well as potential points of human error, were developed. Next, a future-state map was created that included proposed corrections for the most common critical sites of error. Transitioning the current process to the future state will require solutions that address these sites. To optimize the future-state process, a bar code system that links the on-site radiology management system with the nuclear pharmacy management system was proposed. A bar-coded wristband connects the patient directly to the electronic information systems. The bar code-enhanced process linking the patient dose with the electronic information reduces the number of crucial points for human error and provides a framework to ensure that the prepared dose reaches the correct patient. Although the proposed flowchart is designed for a site with an in-house central nuclear pharmacy, much of the framework could be applied by nuclear medicine facilities using unit doses. An electronic connection between information management systems to allow the tracking of a radiopharmaceutical from preparation to administration can be a useful tool in preventing the mistakes that are an unfortunate reality for any facility.

  16. JJ1017 committee report: image examination order codes--standardized codes for imaging modality, region, and direction with local expansion: an extension of DICOM.

    Science.gov (United States)

    Kimura, Michio; Kuranishi, Makoto; Sukenobu, Yoshiharu; Watanabe, Hiroki; Tani, Shigeki; Sakusabe, Takaya; Nakajima, Takashi; Morimura, Shinya; Kabata, Shun

    2002-06-01

    The digital imaging and communications in medicine (DICOM) standard includes parts regarding nonimage data information, such as image study ordering data and performed procedure data, and is used for sharing information between HIS/RIS and modality systems, which is essential for IHE. To bring such parts of the DICOM standard into force in Japan, a joint committee of JIRA and JAHIS established the JJ1017 management guideline, specifying, for example, which items are legally required in Japan, while remaining optional in the DICOM standard. In Japan, the contents of orders from referring physicians for radiographic examinations include details of the examination. Such details are not used typically by referring physicians requesting radiographic examinations in the United States, because radiologists in the United States often determine the examination protocol. The DICOM standard has code tables for examination type, region, and direction for image examination orders. However, this investigation found that it does not include items that are detailed sufficiently for use in Japan, because of the above-mentioned reason. To overcome these drawbacks, we have generated the JJ1017 code for these 3 codes for use based on the JJ1017 guidelines. This report introduces the JJ1017 code. These codes (the study type codes in particular) must be expandable to keep up with technical advances in equipment. Expansion has 2 directions: width for covering more categories and depth for specifying the information in more detail (finer categories). The JJ1017 code takes these requirements into consideration and clearly distinguishes between the stem part as the common term and the expansion. The stem part of the JJ1017 code partially utilizes the DICOM codes to remain in line with the DICOM standard. This work is an example of how local requirements can be met by using the DICOM standard and extending it.

  17. International pressure vessels and piping codes and standards. Volume 2: Current perspectives; PVP-Volume 313-2

    International Nuclear Information System (INIS)

    Rao, K.R.; Asada, Yasuhide; Adams, T.M.

    1995-01-01

    The topics in this volume include: (1) Recent or imminent changes to Section 3 design sections; (2) Select perspectives of ASME Codes -- Section 3; (3) Select perspectives of Boiler and Pressure Vessel Codes -- an international outlook; (4) Select perspectives of Boiler and Pressure Vessel Codes -- ASME Code Sections 3, 8 and 11; (5) Codes and Standards Perspectives for Analysis; (6) Selected design perspectives on flow-accelerated corrosion and pressure vessel design and qualification; (7) Select Codes and Standards perspectives for design and operability; (8) Codes and Standards perspectives for operability; (9) What's new in the ASME Boiler and Pressure Vessel Code?; (10) A look at ongoing activities of ASME Sections 2 and 3; (11) A look at current activities of ASME Section 11; (12) A look at current activities of ASME Codes and Standards; (13) Simplified design methodology and design allowable stresses -- 1 and 2; (14) Introduction to Power Boilers, Section 1 of the ASME Code -- Part 1 and 2. Separate abstracts were prepared for most of the individual papers

  18. Patient safety with blood products administration using wireless and bar-code technology.

    Science.gov (United States)

    Porcella, Aleta; Walker, Kristy

    2005-01-01

    Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.

  19. 78 FR 24725 - National Fire Codes: Request for Public Input for Revision of Codes and Standards

    Science.gov (United States)

    2013-04-26

    ... Production, Storage, and Handling of Liquefied Natural Gas (LNG). NFPA 61--2013 Standard for the 7/6/2015... Nitrate Film. NFPA 51--2013 Standard for the Design 7/6/2015 and Installation of Oxygen-Fuel Gas Systems... Charging Plants. NFPA 52--2013 Vehicular Gaseous Fuel 1/3/2014 Systems Code. NFPA 53--2011 Recommended...

  20. Analysis of the technology acceptance model in examining hospital nurses' behavioral intentions toward the use of bar code medication administration.

    Science.gov (United States)

    Song, Lunar; Park, Byeonghwa; Oh, Kyeung Mi

    2015-04-01

    Serious medication errors continue to exist in hospitals, even though there is technology that could potentially eliminate them such as bar code medication administration. Little is known about the degree to which the culture of patient safety is associated with behavioral intention to use bar code medication administration. Based on the Technology Acceptance Model, this study evaluated the relationships among patient safety culture and perceived usefulness and perceived ease of use, and behavioral intention to use bar code medication administration technology among nurses in hospitals. Cross-sectional surveys with a convenience sample of 163 nurses using bar code medication administration were conducted. Feedback and communication about errors had a positive impact in predicting perceived usefulness (β=.26, Pmodel predicting for behavioral intention, age had a negative impact (β=-.17, Pmodel explained 24% (Ptechnology.

  1. Disease-Specific Trends of Comorbidity Coding and Implications for Risk Adjustment in Hospital Administrative Data.

    Science.gov (United States)

    Nimptsch, Ulrike

    2016-06-01

    To investigate changes in comorbidity coding after the introduction of diagnosis related groups (DRGs) based prospective payment and whether trends differ regarding specific comorbidities. Nationwide administrative data (DRG statistics) from German acute care hospitals from 2005 to 2012. Observational study to analyze trends in comorbidity coding in patients hospitalized for common primary diseases and the effects on comorbidity-related risk of in-hospital death. Comorbidity coding was operationalized by Elixhauser diagnosis groups. The analyses focused on adult patients hospitalized for the primary diseases of heart failure, stroke, and pneumonia, as well as hip fracture. When focusing the total frequency of diagnosis groups per record, an increase in depth of coding was observed. Between-hospital variations in depth of coding were present throughout the observation period. Specific comorbidity increases were observed in 15 of the 31 diagnosis groups, and decreases in comorbidity were observed for 11 groups. In patients hospitalized for heart failure, shifts of comorbidity-related risk of in-hospital death occurred in nine diagnosis groups, in which eight groups were directed toward the null. Comorbidity-adjusted outcomes in longitudinal administrative data analyses may be biased by nonconstant risk over time, changes in completeness of coding, and between-hospital variations in coding. Accounting for such issues is important when the respective observation period coincides with changes in the reimbursement system or other conditions that are likely to alter clinical coding practice. © Health Research and Educational Trust.

  2. Merits and difficulties in adopting codes, standards and nuclear regulations

    International Nuclear Information System (INIS)

    El-Saiedi, A.F.; Morsy, S.; Mariy, A.

    1978-01-01

    Developing countries planning for introducing nuclear power plants as a source of energy have to develop or adopt sound regulatory practices. These are necessary to help governmental authorities to assess the safety of nuclear power plants and to perform inspections needed to confirm the established safe and sound limits. The first requirement is to form an independent regulatory body capable of setting up and enforcing proper safety regulations. The formation of this body is governed by several considerations related to local conditions in the developing countries, which may not always be favourable. It is quite impractical for countries with limited experience in the nuclear power field to develop their own codes, standards and regulations required for the nuclear regulatory body to perform its tasks. A practical way is to adopt codes, standards and regulations of a well-developed country. This has merits as well as drawbacks. The latter are related to problems of personnel, software, equipment and facilities. The difficulties involved in forming a nuclear regulatory body, and the merits and difficulties in adopting foreign codes, standards and regulations required for such body to perform its tasks, are discussed in this paper. Discussions are applicable to many developing countries and particular emphasis is given to the conditions and practices in Egypt. (author)

  3. Phenotypic Graphs and Evolution Unfold the Standard Genetic Code as the Optimal

    Science.gov (United States)

    Zamudio, Gabriel S.; José, Marco V.

    2018-03-01

    In this work, we explicitly consider the evolution of the Standard Genetic Code (SGC) by assuming two evolutionary stages, to wit, the primeval RNY code and two intermediate codes in between. We used network theory and graph theory to measure the connectivity of each phenotypic graph. The connectivity values are compared to the values of the codes under different randomization scenarios. An error-correcting optimal code is one in which the algebraic connectivity is minimized. We show that the SGC is optimal in regard to its robustness and error-tolerance when compared to all random codes under different assumptions.

  4. PERTV: A standard file version of the PERT-V code

    International Nuclear Information System (INIS)

    George, D.C.; LaBauve, R.J.

    1988-02-01

    The PERT-V code, used in two-dimensional perturbation theory, fast reactor analysis, has been modified to accept input data from standard files ISOTXS, GEODST, ZNATDN, NDXSRF, DLAYXS, RTFLUX, and ATFLUX. This modification has greatly reduced the additional input that must be supplied by the user. The new version of PERT-V, PERTV, has all the options of the original code including a plotting capability. 10 refs., 3 figs., 12 tabs

  5. 78 FR 13675 - Federal Acquisition Regulation; Submission for OMB Review; Cost Accounting Standards Administration

    Science.gov (United States)

    2013-02-28

    ...; Submission for OMB Review; Cost Accounting Standards Administration AGENCY: Department of Defense (DOD... collection requirement concerning cost accounting standards administration. A notice was published in the...- 0129, Cost Accounting Standards Administration by any of the following methods: Regulations.gov : http...

  6. Accounting Education Approach in the Context of New Turkish Commercial Code and Turkish Accounting Standards

    Directory of Open Access Journals (Sweden)

    Cevdet Kızıl

    2014-08-01

    Full Text Available The aim of this article is to investigate the impact of new Turkish commercial code and Turkish accounting standards on accounting education. This study takes advantage of the survey method for gathering information and running the research analysis. For this purpose, questionnaire forms are distributed to university students personally and via the internet.This paper includes significant research questions such as “Are accounting academicians informed and knowledgeable on new Turkish commercial code and Turkish accounting standards?”, “Do accounting academicians integrate new Turkish commercial code and Turkish accounting standards to their lectures?”, “How does modern accounting education methodology and technology coincides with the teaching of new Turkish commercial code and Turkish accounting standards?”, “Do universities offer mandatory and elective courses which cover the new Turkish commercial code and Turkish accounting standards?” and “If such courses are offered, what are their names, percentage in the curriculum and degree of coverage?”Research contributes to the literature in several ways. Firstly, new Turkish commercial code and Turkish accounting standards are current significant topics for the accounting profession. Furthermore, the accounting education provides a basis for the implementations in public and private sector. Besides, one of the intentions of new Turkish commercial code and Turkish accounting standards is to foster transparency. That is definitely a critical concept also in terms of mergers, acquisitions and investments. Stakeholders of today’s business world such as investors, shareholders, entrepreneurs, auditors and government are in need of more standardized global accounting principles Thus, revision and redesigning of accounting educations plays an important role. Emphasized points also clearly prove the necessity and functionality of this research.

  7. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.; Halverson, Mark A.

    2013-09-01

    The U.S. Department of Energy’s (DOE) Building America program implemented a new Codes and Standards Innovation (CSI) Team in 2013. The Team’s mission is to assist Building America (BA) research teams and partners in identifying and resolving conflicts between Building America innovations and the various codes and standards that govern the construction of residences. A CSI Roadmap was completed in September, 2013. This guidance document was prepared using the information in the CSI Roadmap to provide BA research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America (BA) innovations arising in and/or stemming from codes, standards, and rating methods. For more information on the BA CSI team, please email: CSITeam@pnnl.gov

  8. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1995-01-01

    A method is described for generating electron cross sections that are compatible with standard discrete ordinates codes without modification. There are many advantages of using an established discrete ordinates solver, e.g. immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and man-made radiation environments. The cross sections have been successfully used in the DORT, TWODANT and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electronphoton transport problems

  9. Indications for spine surgery: validation of an administrative coding algorithm to classify degenerative diagnoses

    Science.gov (United States)

    Lurie, Jon D.; Tosteson, Anna N.A.; Deyo, Richard A.; Tosteson, Tor; Weinstein, James; Mirza, Sohail K.

    2014-01-01

    Study Design Retrospective analysis of Medicare claims linked to a multi-center clinical trial. Objective The Spine Patient Outcomes Research Trial (SPORT) provided a unique opportunity to examine the validity of a claims-based algorithm for grouping patients by surgical indication. SPORT enrolled patients for lumbar disc herniation, spinal stenosis, and degenerative spondylolisthesis. We compared the surgical indication derived from Medicare claims to that provided by SPORT surgeons, the “gold standard”. Summary of Background Data Administrative data are frequently used to report procedure rates, surgical safety outcomes, and costs in the management of spinal surgery. However, the accuracy of using diagnosis codes to classify patients by surgical indication has not been examined. Methods Medicare claims were link to beneficiaries enrolled in SPORT. The sensitivity and specificity of three claims-based approaches to group patients based on surgical indications were examined: 1) using the first listed diagnosis; 2) using all diagnoses independently; and 3) using a diagnosis hierarchy based on the support for fusion surgery. Results Medicare claims were obtained from 376 SPORT participants, including 21 with disc herniation, 183 with spinal stenosis, and 172 with degenerative spondylolisthesis. The hierarchical coding algorithm was the most accurate approach for classifying patients by surgical indication, with sensitivities of 76.2%, 88.1%, and 84.3% for disc herniation, spinal stenosis, and degenerative spondylolisthesis cohorts, respectively. The specificity was 98.3% for disc herniation, 83.2% for spinal stenosis, and 90.7% for degenerative spondylolisthesis. Misclassifications were primarily due to codes attributing more complex pathology to the case. Conclusion Standardized approaches for using claims data to accurately group patients by surgical indications has widespread interest. We found that a hierarchical coding approach correctly classified over 90

  10. Safety standards, legislation and codes of practice for fuel cell manufacture and operation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, C.P.

    1999-07-01

    This report examines safety standards, legislation and codes of practice for fuel cell manufacture and operation in the UK, Europe and internationally. Management of health and safety in the UK is discussed, and the characteristics of phosphoric acid (PAFC), proton exchange membrane (PEM), molten carbonate (MCFC), solid oxide (SOFC) fuel cells are described. Fuel cell power plant standards and manufacture in the UK, design and operational considerations, end of life disposal, automotive fuel cell system, and fuelling and vehicular concerns are explored, and standards, legislation and codes of practice are explained in the appendix.

  11. Accuracy of Administrative Billing Codes to Detect Urinary Tract Infection Hospitalizations

    Science.gov (United States)

    Hall, Matthew; Auger, Katherine A.; Hain, Paul D.; Jerardi, Karen E.; Myers, Angela L.; Rahman, Suraiya S.; Williams, Derek J.; Shah, Samir S.

    2011-01-01

    BACKGROUND: Hospital billing data are frequently used for quality measures and research, but the accuracy of the use of discharge codes to identify urinary tract infections (UTIs) is unknown. OBJECTIVE: To determine the accuracy of International Classification of Diseases, 9th revision (ICD-9) discharge codes to identify children hospitalized with UTIs. METHODS: This multicenter study conducted in 5 children's hospitals included children aged 3 days to 18 years who had been admitted to the hospital, undergone a urinalysis or urine culture, and discharged from the hospital. Data were obtained from the pediatric health information system database and medical record review. With the use of 2 gold-standard methods, the positive predictive value (PPV) was calculated for individual and combined UTI codes and for common UTI identification strategies. PPV was measured for all groupings for which the UTI code was the principal discharge diagnosis. RESULTS: There were 833 patients in the study. The PPV was 50.3% with the use of the gold standard of laboratory-confirmed UTIs but increased to 85% with provider confirmation. Restriction of the study cohort to patients with a principle diagnosis of UTI improved the PPV for laboratory-confirmed UTI (61.2%) and provider-confirmed UTI (93.2%), as well as the ability to benchmark performance. Other common identification strategies did not markedly affect the PPV. CONCLUSIONS: ICD-9 codes can be used to identify patients with UTIs but are most accurate when UTI is the principal discharge diagnosis. The identification strategies reported in this study can be used to improve the accuracy and applicability of benchmarking measures. PMID:21768320

  12. Coding algorithms for identifying patients with cirrhosis and hepatitis B or C virus using administrative data.

    Science.gov (United States)

    Niu, Bolin; Forde, Kimberly A; Goldberg, David S

    2015-01-01

    Despite the use of administrative data to perform epidemiological and cost-effectiveness research on patients with hepatitis B or C virus (HBV, HCV), there are no data outside of the Veterans Health Administration validating whether International Classification of Disease, Ninth Revision, Clinical Modification (ICD-9-CM) codes can accurately identify cirrhotic patients with HBV or HCV. The validation of such algorithms is necessary for future epidemiological studies. We evaluated the positive predictive value (PPV) of ICD-9-CM codes for identifying chronic HBV or HCV among cirrhotic patients within the University of Pennsylvania Health System, a large network that includes a tertiary care referral center, a community-based hospital, and multiple outpatient practices across southeastern Pennsylvania and southern New Jersey. We reviewed a random sample of 200 cirrhotic patients with ICD-9-CM codes for HCV and 150 cirrhotic patients with ICD-9-CM codes for HBV. The PPV of 1 inpatient or 2 outpatient HCV codes was 88.0% (168/191, 95% CI: 82.5-92.2%), while the PPV of 1 inpatient or 2 outpatient HBV codes was 81.3% (113/139, 95% CI: 73.8-87.4%). Several variations of the primary coding algorithm were evaluated to determine if different combinations of inpatient and/or outpatient ICD-9-CM codes could increase the PPV of the coding algorithm. ICD-9-CM codes can identify chronic HBV or HCV in cirrhotic patients with a high PPV and can be used in future epidemiologic studies to examine disease burden and the proper allocation of resources. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Recent development in the ASME O and M committee codes, standards, and guides

    International Nuclear Information System (INIS)

    Rowley, C.W.

    1999-01-01

    The ASME O and M Committee continues to expand and update its code, standards, and guides as contained in the ASME OM Code and the ASME OM Standards/Guides. This paper will describe recent changes to these two ASME documents, including technical inquiries, code cases, and the major reformat of the ASME OM Code 1998 Edition. Also two new Parts to the ASME OM S/G will be discussed: OM Part 23 and OM Part 24, which are close to being initially published. A third new Part to the ASME OM S/G has been authorized and has recently started to get organized: Part 26, 'Thermal Calibration of RTDs'. In addition this paper will describe the future plans for these two documents as provided in the O and M Committee Strategic Plan. (author)

  14. Novice teen driving : education and training administrative standards.

    Science.gov (United States)

    2009-10-09

    The Novice Teen Driver Education and Training Administrative Standards set forth in this document serve to guide all novice teen driver education and training programs in States striving to provide quality, consistent driver education and training. W...

  15. MDEP Technical Report TR-CSWG-02. Technical Report on Lessons Learnt on Achieving Harmonisation of Codes and Standards for Pressure Boundary Components in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2013-01-01

    This report was prepared by the Multinational Design Evaluation Program's (MDEP's) Codes and Standards Working Group (CSWG). The primary, long-term goal of MDEP's CSWG is to achieve international harmonisation of codes and standards for pressure-boundary components in nuclear power plants. The CSWG recognised early on that the first step to achieving harmonisation is to understand the extent of similarities and differences amongst the pressure-boundary codes and standards used in various countries. To assist the CSWG in its long-term goals, several standards developing organisations (SDOs) from various countries performed a comparison of their pressure-boundary codes and standards to identify the extent of similarities and differences in code requirements and the reasons for their differences. The results of the code-comparison project provided the CSWG with valuable insights in developing the subsequent actions to take with SDOs and the nuclear industry to pursue harmonisation of codes and standards. The results enabled the CSWG to understand from a global perspective how each country's pressure-boundary code or standard evolved into its current form and content. The CSWG recognised the important fact that each country's pressure-boundary code or standard is a comprehensive, living document that is continually being updated and improved to reflect changing technology and common industry practices unique to each country. The rules in the pressure-boundary codes and standards include comprehensive requirements for the design and construction of nuclear power plant components including design, materials selection, fabrication, examination, testing and overpressure protection. The rules also contain programmatic and administrative requirements such as quality assurance; conformity assessment (e.g., third-party inspection); qualification of welders, welding equipment and welding procedures; non-destructive examination (NDE) practices and

  16. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    Science.gov (United States)

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Barriers to data quality resulting from the process of coding health information to administrative data: a qualitative study.

    Science.gov (United States)

    Lucyk, Kelsey; Tang, Karen; Quan, Hude

    2017-11-22

    Administrative health data are increasingly used for research and surveillance to inform decision-making because of its large sample sizes, geographic coverage, comprehensivity, and possibility for longitudinal follow-up. Within Canadian provinces, individuals are assigned unique personal health numbers that allow for linkage of administrative health records in that jurisdiction. It is therefore necessary to ensure that these data are of high quality, and that chart information is accurately coded to meet this end. Our objective is to explore the potential barriers that exist for high quality data coding through qualitative inquiry into the roles and responsibilities of medical chart coders. We conducted semi-structured interviews with 28 medical chart coders from Alberta, Canada. We used thematic analysis and open-coded each transcript to understand the process of administrative health data generation and identify barriers to its quality. The process of generating administrative health data is highly complex and involves a diverse workforce. As such, there are multiple points in this process that introduce challenges for high quality data. For coders, the main barriers to data quality occurred around chart documentation, variability in the interpretation of chart information, and high quota expectations. This study illustrates the complex nature of barriers to high quality coding, in the context of administrative data generation. The findings from this study may be of use to data users, researchers, and decision-makers who wish to better understand the limitations of their data or pursue interventions to improve data quality.

  18. An exploration of administrators' perceptions of elementary science: A case study of the role of science in two elementary schools based on the interactions of administrators with colleagues, science content and state standards

    Science.gov (United States)

    Brogdon, Lori-Anne Stelmark

    This research is a case study on the perceptions and attitudes of administrators in the area of elementary science and how their responses reflect agreement or dissonance with the perceptions of elementary teachers on the subject of science within the same district. The study used Likert-type surveys and interviews from both administrators and teachers on five key areas: 1) Attitudes towards science and teaching 2) Attitudes towards teaching science 3) Attitudes towards administrators 4) Time teaching science and 5) Attitudes about policy and standards. Survey data was analyzed within and across areas to identify similarity and difference within each group. The medians from the administrative and teacher surveys were then crossed referenced through the use of a Mann Whitney test to identify areas of similarity. Interview data was coded around three major themes: 1) Standards 2) Classroom Instruction and 3) Conversations. The findings show that even though administrators' perceptions favor the inclusion of science in the elementary classroom, both administrators and teachers in this study reported limited involvement from, and conversation with, each other on the topic of science education. Heavy reliance by the administrators was placed on the use of consultants to provide professional development in the area of science instruction and to review the use of state standards, resulting in limited conversation between administrators and teachers about science. Teachers reported a heavy reliance upon their colleagues in the area of science instruction and curriculum planning. In addition, both administrators and teachers reported a greater focus on math and English for classroom instruction. Findings in this research support implications that more focus should be placed on the role of administrators in the implementation of science instruction. Administrators can play a crucial role in the success of science programs at the building, district and state levels

  19. Final Technical Report for GO17004 Regulatory Logic: Codes and Standards for the Hydrogen Economy

    Energy Technology Data Exchange (ETDEWEB)

    Nakarado, Gary L. [Regulatory Logic LLC, Golden, CO (United States)

    2017-02-22

    The objectives of this project are to: develop a robust supporting research and development program to provide critical hydrogen behavior data and a detailed understanding of hydrogen combustion and safety across a range of scenarios, needed to establish setback distances in building codes and minimize the overall data gaps in code development; support and facilitate the completion of technical specifications by the International Organization for Standardization (ISO) for gaseous hydrogen refueling (TS 20012) and standards for on-board liquid (ISO 13985) and gaseous or gaseous blend (ISO 15869) hydrogen storage by 2007; support and facilitate the effort, led by the NFPA, to complete the draft Hydrogen Technologies Code (NFPA 2) by 2008; with experimental data and input from Technology Validation Program element activities, support and facilitate the completion of standards for bulk hydrogen storage (e.g., NFPA 55) by 2008; facilitate the adoption of the most recently available model codes (e.g., from the International Code Council [ICC]) in key regions; complete preliminary research and development on hydrogen release scenarios to support the establishment of setback distances in building codes and provide a sound basis for model code development and adoption; support and facilitate the development of Global Technical Regulations (GTRs) by 2010 for hydrogen vehicle systems under the United Nations Economic Commission for Europe, World Forum for Harmonization of Vehicle Regulations and Working Party on Pollution and Energy Program (ECE-WP29/GRPE); and to Support and facilitate the completion by 2012 of necessary codes and standards needed for the early commercialization and market entry of hydrogen energy technologies.

  20. Comparison of the General Electric BWR/6 standard plant design to the IAEA NUSS codes and guides

    International Nuclear Information System (INIS)

    D'Ardenne, W.H.; Sherwood, G.G.

    1985-01-01

    The General Electric BWR/6 Mark III standard plant design meets or exceeds current requirements of published International Atomic Energy Agency (IAEA) Nuclear Safety Standards (NUSS) codes and guides. This conclusion is based on a review of the NUSS codes and guides by General Electric and by the co-ordinated US review of the NUSS codes and guides during their development. General Electric compared the published IAEA NUSS codes and guides with the General Electric design. The applicability of each code and guide to the BWR/6 Mark III standard plant design was determined. Each code or guide was reviewed by a General Electric engineer knowledgeable about the structures, systems and components addressed and the technical area covered by that code or guide. The results of this review show that the BWR/6 Mark III standard plant design meets or exceeds the applicable requirements of the published IAEA NUSS codes and guides. The co-ordinated US review of the IAEA NUSS codes and guides corroborates the General Electric review. In the co-ordinated US review, the USNRC and US industry organizations (including General Electric) review the NUSS codes and guides during their development. This review ensures that the NUSS codes and guides are consistent with the current US government regulations, guidance and regulatory practices, US voluntary industry codes and standards, and accepted US industry design, construction and operational practices. If any inconsistencies are identified, comments are submitted to the IAEA by the USNRC. All US concerns submitted to the IAEA have been resolved. General Electric design reviews and the Final Design Approval (FDA) issued by the USNRC have verified that the General Electric BWR/6 Mark III standard plant design meets or exceeds the current US requirements, guidance and practices. Since these requirements, guidance and practices meet or exceed those of the NUSS codes and guides, so does the General Electric design. (author)

  1. MARS-KS code validation activity through the atlas domestic standard problem

    International Nuclear Information System (INIS)

    Choi, K. Y.; Kim, Y. S.; Kang, K. H.; Park, H. S.; Cho, S.

    2012-01-01

    The 2 nd Domestic Standard Problem (DSP-02) exercise using the ATLAS integral effect test data was executed to transfer the integral effect test data to domestic nuclear industries and to contribute to improving the safety analysis methodology for PWRs. A small break loss of coolant accident of a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. Ten calculation results using MARS-KS code were collected, major prediction results were described qualitatively and code prediction accuracy was assessed quantitatively using the FFTBM. In addition, special code assessment activities were carried out to find out the area where the model improvement is required in the MARS-KS code. The lessons from this DSP-02 and recommendations to code developers are described in this paper. (authors)

  2. R&D for Safety Codes and Standards: Materials and Components Compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Somerday, Brian P. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); LaFleur, Chris [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Marchi, Chris San [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-08-01

    This project addresses the following technical barriers from the Safety, Codes and Standards section of the 2012 Fuel Cell Technologies Office Multi-Year Research, Development and Demonstration Plan (section 3.8): (A) Safety data and information: limited access and availability (F) Enabling national and international markets requires consistent RCS (G) Insufficient technical data to revise standards.

  3. Video coding standards AVS China, H.264/MPEG-4 PART 10, HEVC, VP6, DIRAC and VC-1

    CERN Document Server

    Rao, K R; Hwang, Jae Jeong

    2014-01-01

    Review by Ashraf A. Kassim, Professor, Department of Electrical & Computer Engineering, and Associate Dean, School of Engineering, National University of Singapore.     The book consists of eight chapters of which the first two provide an overview of various video & image coding standards, and video formats. The next four chapters present in detail the Audio & video standard (AVS) of China, the H.264/MPEG-4 Advanced video coding (AVC) standard, High efficiency video coding (HEVC) standard and the VP6 video coding standard (now VP10) respectively. The performance of the wavelet based Dirac video codec is compared with H.264/MPEG-4 AVC in chapter 7. Finally in chapter 8, the VC-1 video coding standard is presented together with VC-2 which is based on the intra frame coding of Dirac and an outline of a H.264/AVC to VC-1 transcoder.   The authors also present and discuss relevant research literature such as those which document improved methods & techniques, and also point to other related reso...

  4. 75 FR 57297 - Petitions for Modification of Existing Mandatory Safety Standards

    Science.gov (United States)

    2010-09-20

    ... safety standards published in Title 30 of the Code of Federal Regulations. DATES: All comments on the... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration (MSHA), Labor. ACTION: Notice...

  5. 76 FR 16640 - Petitions for Modification of Existing Mandatory Safety Standards

    Science.gov (United States)

    2011-03-24

    ... safety standards published in Title 30 of the Code of Federal Regulations. DATES: All comments on the... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration (MSHA), Labor. ACTION: Notice...

  6. Harmonization of nuclear codes and standards. Pacific nuclear council working and task group report

    International Nuclear Information System (INIS)

    Dua, Shami

    2008-01-01

    Nuclear codes and standards have been an integral part of the nuclear industry since its inception. As the industry came into the main stream over the 2nd half of the 20th century, a number of national and international standards were developed to support a specific nuclear reactor concept. These codes and standards have been a key component of the industry to maintain its focus on nuclear safety, reliability and quality. Both national and international standards have served the industry well in obtaining public, shareholder and regulatory acceptance. The existing suite of national and international standards is required to support the emerging nuclear renaissance. However as noted above under Pacific Nuclear Council (PNC), Manufacturing Design Evaluation Program (MDEP) and SMiRT discussions, the time has come now for the codes and standards writing bodies and the industry to take the next step to examine the relevance of existing suite in view of current needs and challenges. This review must account for the changing global environment including global supply chain and regulatory framework, resources, deregulation, free trade, and industry need for competitiveness and performance excellence. The Task Group (TG) has made limited progress in this review period as no additional information on the listing of codes and standards have been received from the members. However, TG Chair has been successful in obtaining considerable interest from some additional individuals from the member countries. It is important that PNC management seek additional participation from the member countries and asks for their active engagement in the Working Group (WG) TG activities to achieve its mandate and deliverables. The harmonization of codes and standards is a key area for the emerging nuclear renaissance and as noted by a number of international organizations (refer to MDEP action noted above) that these tasks can not be completed unless we have the right level of resources and

  7. 78 FR 57445 - Charging Standard Administrative Fees for Nonprogram-Related Information

    Science.gov (United States)

    2013-09-18

    ... the Federal Register a schedule of standardized administrative fees we charge to recover the full cost... fee schedule is outdated and incongruent with the agency's current costs for this service. New... new standard fee on our most recent cost calculations for supplying this information and the standard...

  8. Towards an International Code for administrative cooperation in tax matter and international tax governance

    Directory of Open Access Journals (Sweden)

    Eva Andrés Aucejo

    2017-12-01

    Full Text Available There is not a “Global Code” that encodes the duty of cooperation between tax authorities in the world, concerning the global tax system. This article addresses this issue by proposing a global Code of administrative cooperation in tax matters including both tax relations: between States, and between States, taxpayers and intermediary’s agents. It follows a wide concept of tax governance. The findings of this research have highlighted several practical applications for future practice. article analyses, firstly, the State of the question, starting with the legal sources (international and European sources of hard law and soft law reviewing the differences with the Code as here proposed. It also examines some important Agents who emit relevant normative in international administrative tax cooperation and the role that these agents are developing nowadays (sometimes international organizations but also States like the United States, which Congress enacted the Foreign Account Tax Compliance Act, FATCA. Overlapping and gaps between different regulations are underlined. Finally, the consequences of this “General Code” lack for the functioning of a good international governance, are described. Hence, the need to create an International Cooperation Code on tax matters and international fiscal governance is concluded. That Code could be proposed by any International Organization as the World Bank nature, for instance, or the International Monetary Fund or whichever International or European Organization. This instrument could be documented through a multilateral instrument (soft law, to be signed by the States to become an international legal source (hard law. Filling this Code as Articulated Text (form could be very useful for the International Community towards an International Tax Governance.

  9. Harmonization of nuclear codes and standards, pacific nuclear council working and task group report

    International Nuclear Information System (INIS)

    Dua, S.S.

    2006-01-01

    Full text: The codes and standards, both at the national and international level, have had a major impact on the industry worldwide and served it well in maintaining the performance and safety of the nuclear reactors and facilities. The codes and standards, in general, are consensus documents and do seek public input at various levels before they are finalized and rolled out for use by the nuclear vendors, consultants, utilities and regulatory bodies. However, the extensive development of prescriptive national standards if unchecked against the global environment and trade agreements (NAFTA, WTO, etc.) can also become barriers and cause difficulties to compete in the world market. During the last decade, the national and international writing standards writing bodies have recognized these issues and are moving more towards the rationalization and harmonization of their standards with the more widely accepted generic standards. The Pacific Nuclear Council (PNC) recognized the need for harmonization of the nuclear codes and standards for its member countries and formed a Task Group to achieve its objectives. The Task Group has a number of members from the PNC member countries. In 2005 PNC further raised the importance of this activity and formed a Working Group to cover a broader scope. The Working Group (WG) mandate is to identify and analyze the different codes and standards introduced to the Pacific Basin region, in order to achieve mutual understanding, harmonization and application in each country. This o requires the WG to develop and encourage the use of reasonably consistent criteria for the design and development, engineering, procurement, fabrication, construction, testing, operations, maintenance, waste management, decommissioning and the management of the commercial nuclear power plants in the Pacific Basin so as to: Promote consistent safety, quality, environmental and management standards for nuclear energy and other peaceful applications of nuclear

  10. DOE standard: The Department of Energy Laboratory Accreditation Program administration

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP), organizational responsibilities, and the accreditation process. DOELAP evaluates and accredits personnel dosimetry and radiobioassay programs used for worker monitoring and protection at DOE and DOE contractor sites and facilities as required in Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection. The purpose of this technical standard is to establish procedures for administering DOELAP and acquiring accreditation

  11. Filtering authentic sepsis arising in the ICU using administrative codes coupled to a SIRS screening protocol.

    Science.gov (United States)

    Sudduth, Christopher L; Overton, Elizabeth C; Lyu, Peter F; Rimawi, Ramzy H; Buchman, Timothy G

    2017-06-01

    Using administrative codes and minimal physiologic and laboratory data, we sought a high-specificity identification strategy for patients whose sepsis initially appeared during their ICU stay. We studied all patients discharged from an academic hospital between September 1, 2013 and October 31, 2014. Administrative codes and minimal physiologic and laboratory criteria were used to identify patients at high risk of developing the onset of sepsis in the ICU. Two clinicians then independently reviewed the patient record to verify that the screened-in patients appeared to become septic during their ICU admission. Clinical chart review verified sepsis in 437/466 ICU stays (93.8%). Of these 437 encounters, only 151 (34.6%) were admitted to the ICU with neither SIRS nor evidence of infection and therefore appeared to become septic during their ICU stay. Selected administrative codes coupled to SIRS criteria and applied to patients admitted to ICU can yield up to 94% authentic sepsis patients. However, only 1/3 of patients thus identified appeared to become septic during their ICU stay. Studies that depend on high-intensity monitoring for description of the time course of sepsis require clinician review and verification that sepsis initially appeared during the monitoring period. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Administrative database concerns: accuracy of International Classification of Diseases, Ninth Revision coding is poor for preoperative anemia in patients undergoing spinal fusion.

    Science.gov (United States)

    Golinvaux, Nicholas S; Bohl, Daniel D; Basques, Bryce A; Grauer, Jonathan N

    2014-11-15

    Cross-sectional study. To objectively evaluate the ability of International Classification of Diseases, Ninth Revision (ICD-9) codes, which are used as the foundation for administratively coded national databases, to identify preoperative anemia in patients undergoing spinal fusion. National database research in spine surgery continues to rise. However, the validity of studies based on administratively coded data, such as the Nationwide Inpatient Sample, are dependent on the accuracy of ICD-9 coding. Such coding has previously been found to have poor sensitivity to conditions such as obesity and infection. A cross-sectional study was performed at an academic medical center. Hospital-reported anemia ICD-9 codes (those used for administratively coded databases) were directly compared with the chart-documented preoperative hematocrits (true laboratory values). A patient was deemed to have preoperative anemia if the preoperative hematocrit was less than the lower end of the normal range (36.0% for females and 41.0% for males). The study included 260 patients. Of these, 37 patients (14.2%) were anemic; however, only 10 patients (3.8%) received an "anemia" ICD-9 code. Of the 10 patients coded as anemic, 7 were anemic by definition, whereas 3 were not, and thus were miscoded. This equates to an ICD-9 code sensitivity of 0.19, with a specificity of 0.99, and positive and negative predictive values of 0.70 and 0.88, respectively. This study uses preoperative anemia to demonstrate the potential inaccuracies of ICD-9 coding. These results have implications for publications using databases that are compiled from ICD-9 coding data. Furthermore, the findings of the current investigation raise concerns regarding the accuracy of additional comorbidities. Although administrative databases are powerful resources that provide large sample sizes, it is crucial that we further consider the quality of the data source relative to its intended purpose.

  13. Analyses in support of risk-informed natural gas vehicle maintenance facility codes and standards :

    Energy Technology Data Exchange (ETDEWEB)

    Ekoto, Isaac W.; Blaylock, Myra L.; LaFleur, Angela Christine; LaChance, Jeffrey L.; Horne, Douglas B.

    2014-03-01

    Safety standards development for maintenance facilities of liquid and compressed gas fueled large-scale vehicles is required to ensure proper facility design and operation envelopes. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase I work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest. Finally, scenario analyses were performed using detailed simulations and modeling to estimate the overpressure hazards from HAZOP defined scenarios. The results from Phase I will be used to identify significant risk contributors at NGV maintenance facilities, and are expected to form the basis for follow-on quantitative risk analysis work to address specific code requirements and identify effective accident prevention and mitigation strategies.

  14. The emerging High Efficiency Video Coding standard (HEVC)

    International Nuclear Information System (INIS)

    Raja, Gulistan; Khan, Awais

    2013-01-01

    High definition video (HDV) is becoming popular day by day. This paper describes the performance analysis of latest upcoming video standard known as High Efficiency Video Coding (HEVC). HEVC is designed to fulfil all the requirements for future high definition videos. In this paper, three configurations (intra only, low delay and random access) of HEVC are analyzed using various 480p, 720p and 1080p high definition test video sequences. Simulation results show the superior objective and subjective quality of HEVC

  15. Study of relationship between radioactivity distribution, contamination burden and quality standard, accommodate energy of code river Yogyakarta

    International Nuclear Information System (INIS)

    Agus Taftazani and Muzakky

    2009-01-01

    Study of relationship between distribution, contamination burden of gross β radioactivity and natural radionuclide in water and sediment sample from 11 observation station Code river to quality standard and maximum capacity of Code river have been done. Natural radio nuclides identification and gross β radioactivity measurement of condensed water, dry and homogeneous sediment powder (past through 100 mesh sieve) samples have been done by using spectrometer and GM counter. Radioactivity data was analyzed descriptive with histogram to show the spreading pattern of data. Contamination burden data, quality standard and maximum capacity of river Code was to descriptive analyzed by line diagram to knowing relationship between contamination burden, quality standard, and maximum capacity of Code river. The observation of water and sediment at 11 observation station show that the emitter natural radionuclides: 210 Pb, 212 Pb, 214 Pb, 226 Ra, 208 Tl, 214 Bi, 228 Ac and 40 K were detected. The analytical result conclusion was that the pattern spread of average activity gross β and were increase from upstream to downstream of the Code river samples. Contamination burden, quality standard and maximum capacity of radionuclide activity of 210 Pb, 212 Pb, 226 Ra and 228 Ac were more smaller than quality standard of river water according to regulation of Nuclear Energy Regulatory Agency 02/Ka-BAPETEN/V-99 concerning quality standard of radioactivity. It’s mean that Code river still in good contamination burden for the four radionuclides. (author)

  16. 21 CFR 19.6 - Code of ethics for government service.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Code of ethics for government service. 19.6 Section 19.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL STANDARDS OF CONDUCT AND CONFLICTS OF INTEREST General Provisions § 19.6 Code of ethics for government...

  17. TANDA TANGAN DIGITAL MENGGUNAKAN QR CODE DENGAN METODE ADVANCED ENCRYPTION STANDARD

    Directory of Open Access Journals (Sweden)

    Abdul Gani Putra Suratma

    2017-04-01

    Full Text Available Tanda tangan digital (digital signature adalah sebuah skema matematis yang secara unik mengidentifikasikan seorang pengirim, sekaligus untuk membuktikan keaslian dari pemilik sebuah pesan atau dokumen digital, sehingga sebuah tanda tangan digital yang autentik (sah, sudah cukup menjadi alasan bagi penerima un- tuk percaya bahwa sebuah pesan atau dokumen yang diterima adalah berasal dari pengirim yang telah diketahui. Perkembangan teknologi memungkinkan adanya tanda tangan digital yang dapat digunakan untuk melakukan pembuktian secara matematis, sehingga informasi yang didapat oleh satu pihak dari pihak lain dapat diidentifikasi untuk memastikan keaslian informasi yang diterima. Tanda tangan digital merupakan mekanisme otentikasi yang memungkinkan pembuat pesan menambahkan sebuah kode yang bertindak sebagai tanda tangannya. Tujuan dari penelitian ini menerapkan QR Code atau yang dikenal dengan istilah QR (Quick Respon dan Algoritma yang akan ditambahkan yaitu AES (Advanced Encryption Standard sebagai tanda tangan digital sehingga hasil dari penelitian penerapan QR Code menggunakan algoritma Advanced Encryption Standard sebagai tanda tangan digital dapat berfungsi sebagai otentikasi tanda tangan pimpinan serta ve- rivikasi dokumen pengambilan barang yang sah. dari penelitian ini akurasi klasifi- kasi QR Code dengan menggunakan naïve bayes classifier sebesar 90% dengan precision positif sebesar 80% dan precision negatif sebesar 100%.

  18. Verification of thermal-hydraulic computer codes against standard problems for WWER reflooding

    International Nuclear Information System (INIS)

    Alexander D Efanov; Vladimir N Vinogradov; Victor V Sergeev; Oleg A Sudnitsyn

    2005-01-01

    Full text of publication follows: The computational assessment of reactor core components behavior under accident conditions is impossible without knowledge of the thermal-hydraulic processes occurring in this case. The adequacy of the results obtained using the computer codes to the real processes is verified by carrying out a number of standard problems. In 2000-2003, the fulfillment of three Russian standard problems on WWER core reflooding was arranged using the experiments on full-height electrically heated WWER 37-rod bundle model cooldown in regimes of bottom (SP-1), top (SP-2) and combined (SP-3) reflooding. The representatives from the eight MINATOM's organizations took part in this work, in the course of which the 'blind' and posttest calculations were performed using various versions of the RELAP5, ATHLET, CATHARE, COBRA-TF, TRAP, KORSAR computer codes. The paper presents a brief description of the test facility, test section, test scenarios and conditions as well as the basic results of computational analysis of the experiments. The analysis of the test data revealed a significantly non-one-dimensional nature of cooldown and rewetting of heater rods heated up to a high temperature in a model bundle. This was most pronounced at top and combined reflooding. The verification of the model reflooding computer codes showed that most of computer codes fairly predict the peak rod temperature and the time of bundle cooldown. The exception is provided by the results of calculations with the ATHLET and CATHARE codes. The nature and rate of rewetting front advance in the lower half of the bundle are fairly predicted practically by all computer codes. The disagreement between the calculations and experimental results for the upper half of the bundle is caused by the difficulties of computational simulation of multidimensional effects by 1-D computer codes. In this regard, a quasi-two-dimensional computer code COBRA-TF offers certain advantages. Overall, the closest

  19. Japanese national project for establishment of codes and standards for stationary PEFC system

    International Nuclear Information System (INIS)

    Sumi, S.; Ohmura, T.; Yamaguchi, R.; Kikuzawa, H.

    2003-01-01

    For the purpose of practical utilization of the PEFC cogeneration system, we are promoting the national projects of the 'Establishment of Codes and Standards for Stationary PEFC System'. The objective is to prepare the software platforms for wide spreading use, which are required in the introduction stage of the PEFC cogeneration systems, such as code and standards for safety, reliability, performance and so on. For this objective, using test samples of the systems and the stacks, developments of test and evaluation devices, collection of various kinds of data and establishment of test and evaluation methods are under way. (author)

  20. Report on the Current Technical Issues on ASME Nuclear Code and Standard

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Lee, B. S.; Yoo, S. H.

    2008-11-01

    This report describes the analysis on the current revision movement related to the mechanical design issues of the U.S ASME nuclear code and standard. ASME nuclear mechanical design in this report is composed of the nuclear material, primary system, secondary system and high temperature reactor. This report includes the countermeasures based on the ASME Code meeting for current issues of each major field. KAMC(ASME Mirror Committee) of this project is willing to reflect a standpoint of the domestic nuclear industry on ASME nuclear mechanical design and play a technical bridge role for the domestic nuclear industry in ASME Codes application

  1. Review and Implementation of the Emerging CCSDS Recommended Standard for Multispectral and Hyperspectral Lossless Image Coding

    Science.gov (United States)

    Sanchez, Jose Enrique; Auge, Estanislau; Santalo, Josep; Blanes, Ian; Serra-Sagrista, Joan; Kiely, Aaron

    2011-01-01

    A new standard for image coding is being developed by the MHDC working group of the CCSDS, targeting onboard compression of multi- and hyper-spectral imagery captured by aircraft and satellites. The proposed standard is based on the "Fast Lossless" adaptive linear predictive compressor, and is adapted to better overcome issues of onboard scenarios. In this paper, we present a review of the state of the art in this field, and provide an experimental comparison of the coding performance of the emerging standard in relation to other state-of-the-art coding techniques. Our own independent implementation of the MHDC Recommended Standard, as well as of some of the other techniques, has been used to provide extensive results over the vast corpus of test images from the CCSDS-MHDC.

  2. Using Procedure Codes to Define Radiation Toxicity in Administrative Data: The Devil is in the Details.

    Science.gov (United States)

    Meyer, Anne-Marie; Kuo, Tzy-Mey; Chang, YunKyung; Carpenter, William R; Chen, Ronald C; Sturmer, Til

    2017-05-01

    Systematic coding systems are used to define clinically meaningful outcomes when leveraging administrative claims data for research. How and when these codes are applied within a research study can have implications for the study validity and their specificity can vary significantly depending on treatment received. Data are from the Surveillance, Epidemiology, and End Results-Medicare linked dataset. We use propensity score methods in a retrospective cohort of prostate cancer patients first examined in a recently published radiation oncology comparative effectiveness study. With the narrowly defined outcome definition, the toxicity event outcome rate ratio was 0.88 per 100 person-years (95% confidence interval, 0.71-1.08). With the broadly defined outcome, the rate ratio was comparable, with 0.89 per 100 person-years (95% confidence interval, 0.76-1.04), although individual event rates were doubled. Some evidence of surveillance bias was suggested by a higher rate of endoscopic procedures the first year of follow-up in patients who received proton therapy compared with those receiving intensity-modulated radiation treatment (11.15 vs. 8.90, respectively). This study demonstrates the risk of introducing bias through subjective application of procedure codes. Careful consideration is required when using procedure codes to define outcomes in administrative data.

  3. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    Science.gov (United States)

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  4. Validation of key behaviourally based mental health diagnoses in administrative data: suicide attempt, alcohol abuse, illicit drug abuse and tobacco use

    OpenAIRE

    Kim Hyungjin; Smith Eric G; Stano Claire M; Ganoczy Dara; Zivin Kara; Walters Heather; Valenstein Marcia

    2012-01-01

    Abstract Background Observational research frequently uses administrative codes for mental health or substance use diagnoses and for important behaviours such as suicide attempts. We sought to validate codes (International Classification of Diseases, 9th edition, clinical modification diagnostic and E-codes) entered in Veterans Health Administration administrative data for patients with depression versus a gold standard of electronic medical record text ("chart notation"). Methods Three rando...

  5. Regulatory Endorsement Activities for ASME Nuclear Codes and Standards

    International Nuclear Information System (INIS)

    West, Raymond A.

    2006-01-01

    The ASME Board on Nuclear Codes and Standards (BNCS) has formed a Task Group on Regulatory Endorsement (TG-RE) that is currently in discussions with the United States Nuclear Regulatory Commission (NRC) to look at suggestions and recommendations that can be used to help with the endorsement of new and revised ASME Nuclear Codes and Standards (NC and S). With the coming of new reactors in the USA in the very near future we need to look at both the regulations and all the ASME NC and S to determine where we need to make changes to support these new plants. At the same time it is important that we maintain our operating plants while addressing ageing management needs of our existing reactors. This is going to take new thinking, time, resources, and money. For all this to take place the regulations and requirements that we use must be clear concise and necessary for safety and to that end both the NRC and ASME are working together to make this happen. Because of the influence that the USA has in the world in dealing with these issues, this paper is written to inform the international nuclear engineering community about the issues and what actions are being addressed under this effort. (author)

  6. Review of ASME nuclear codes and standards- subcommittee on repairs, replacements, and modifications

    International Nuclear Information System (INIS)

    Mawson, T.J.

    1990-01-01

    As requested by the ASME board on Nuclear Codes and Standards, the Pressure Vessel Research Committee initiated a project to review Sections III and XI of the ASME Boiler and Pressure Vessel Code for the purposes of improving, clarifying, providing transition, consistency, compatibility, and simplifying code requirements. The project was organized with six subcommittees to address various Code activities: design; tests and examinations; documentation; quality assurance; repair, replacement and modification; and general requirements. This paper discusses how the subcommittee on repair, replacement and modification was organized to review the repair, replacement and modification requirements of the ASME boiler and pressure vessel code, Section III and Section XI for Class 1, 2, and 3 and MC components and their supports, and other documents of the nuclear industry related to the repair, replacement and modification requirements of the ASME code

  7. Oil and gas field code master list 1994

    Energy Technology Data Exchange (ETDEWEB)

    1995-01-01

    This is the thirteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1994 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. The master field name spellings and codes are to be used by respondents when filing the following Department of Energy (DOE) forms: Form EIA-23, {open_quotes}Annual Survey of Domestic Oil and Gas Reserves,{close_quotes} filed by oil and gas well operators (field codes are required from larger operators only); Forms FERC 8 and EIA-191, {open_quotes}Underground Gas Storage Report,{close_quotes} filed by natural gas producers and distributors who operate underground natural gas storage facilities. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161, (703) 487-4650. In order for the Master List to be useful, it must be accurate and remain current. To accomplish this, EIA constantly reviews and revises this list. The EIA welcomes all comments, corrections, and additions to the Master List. All such information should be given to the EIA Field Code Coordinator at (214) 953-1858. EIA gratefully acknowledges the assistance provides by numerous State organizations and trade associations in verifying the existence of fields and their official nomenclature.

  8. JAERI thermal reactor standard code system for reactor design and analysis SRAC

    International Nuclear Information System (INIS)

    Tsuchihashi, Keichiro

    1985-01-01

    SRAC, JAERI thermal reactor standard code system for reactor design and analysis, developed in Japan Atomic Energy Research Institute, is for all types of thermal neutron nuclear design and analysis. The code system has undergone extensive verifications to confirm its functions, and has been used in core modification of the research reactor, detailed design of the multi-purpose high temperature gas reactor and analysis of the experiment with a critical assembly. In nuclear calculation with the code system, multi-group lattice calculation is first made with the libraries. Then, with the resultant homogeneous equivalent group constants, reactor core calculation is made. Described are the following: purpose and development of the code system, functions of the SRAC system, bench mark tests and usage state and future development. (Mori, K.)

  9. 22 CFR 226.42 - Codes of conduct.

    Science.gov (United States)

    2010-04-01

    ... Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Procurement Standards § 226.42 Codes of conduct. The recipient shall... immediate family, his or her partner, or an organization which employs or is about to employ any of the...

  10. 76 FR 70414 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards

    Science.gov (United States)

    2011-11-14

    ... Commercial Cooking Operations. NFPA 99--2012 Health Care Facilities Code 6/22/2012 NFPA 99B--2010 Standard... Explosion Investigations..... 1/4/2012 NFPA 1005--2007 Standard for Professional Qualifications for 1/4/2012 Marine Fire Fighting for Land-Based Fire Fighters. NFPA 1021--2009 Standard for Fire Officer Professional...

  11. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    Science.gov (United States)

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes

  12. 77 FR 50757 - Charging Standard Administrative Fees for Nonprogram-Related Information

    Science.gov (United States)

    2012-08-22

    ... are announcing the standardized administrative fees we will charge to recover our full cost of... will ensure fees are consistent and that we collect the full cost of supplying our information when a... standard fees that are calculated to reflect the full cost of providing information for nonprogram-related...

  13. The road to a standard land administration domain model, and beyond ...

    NARCIS (Netherlands)

    Lemmen, C.H.J.; Uitermark, H.T.; Van Oosterom, P.J.M.; Zevenbergen, J.A.; Greenway, I.

    2011-01-01

    The Land Administration Domain Model (LADM) is a Draft International Standard (ISO DIS 19152) and in January 2011 was distributed by the ISO central secretariat for a five month voting and commenting time interval. If everything goes as planned, ISO 19152 will be an International Standard (IS) by

  14. Hospital Standardized Mortality Ratios: Sensitivity Analyses on the Impact of Coding

    Science.gov (United States)

    Bottle, Alex; Jarman, Brian; Aylin, Paul

    2011-01-01

    Introduction Hospital standardized mortality ratios (HSMRs) are derived from administrative databases and cover 80 percent of in-hospital deaths with adjustment for available case mix variables. They have been criticized for being sensitive to issues such as clinical coding but on the basis of limited quantitative evidence. Methods In a set of sensitivity analyses, we compared regular HSMRs with HSMRs resulting from a variety of changes, such as a patient-based measure, not adjusting for comorbidity, not adjusting for palliative care, excluding unplanned zero-day stays ending in live discharge, and using more or fewer diagnoses. Results Overall, regular and variant HSMRs were highly correlated (ρ > 0.8), but differences of up to 10 points were common. Two hospitals were particularly affected when palliative care was excluded from the risk models. Excluding unplanned stays ending in same-day live discharge had the least impact despite their high frequency. The largest impacts were seen when capturing postdischarge deaths and using just five high-mortality diagnosis groups. Conclusions HSMRs in most hospitals changed by only small amounts from the various adjustment methods tried here, though small-to-medium changes were not uncommon. However, the position relative to funnel plot control limits could move in a significant minority even with modest changes in the HSMR. PMID:21790587

  15. IAEA Workshop (Training Course) on Codes and Standards for Sodium Cooled Fast Reactors. Working Material

    International Nuclear Information System (INIS)

    2010-01-01

    The training course consisted of lectures and Q&A sessions. The lectures dealt with the history of the development of Design Codes and Standards for Sodium Cooled Fast Reactors (SFRs) in the respective country, the detailed description of the current design Codes and Standards for SFRs and their application to ongoing Fast Reactor design projects, as well as the ongoing development work and plans for the future in this area. Annex 1 contains the detailed Workshop program

  16. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    Science.gov (United States)

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (Psystem offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. More Than Bar Codes: Integrating Global Standards-Based Bar Code Technology Into National Health Information Systems in Ethiopia and Pakistan to Increase End-to-End Supply Chain Visibility.

    Science.gov (United States)

    Hara, Liuichi; Guirguis, Ramy; Hummel, Keith; Villanueva, Monica

    2017-12-28

    The United Nations Population Fund (UNFPA) and the United States Agency for International Development (USAID) DELIVER PROJECT work together to strengthen public health commodity supply chains by standardizing bar coding under a single set of global standards. From 2015, UNFPA and USAID collaborated to pilot test how tracking and tracing of bar coded health products could be operationalized in the public health supply chains of Ethiopia and Pakistan and inform the ecosystem needed to begin full implementation. Pakistan had been using proprietary bar codes for inventory management of contraceptive supplies but transitioned to global standards-based bar codes during the pilot. The transition allowed Pakistan to leverage the original bar codes that were preprinted by global manufacturers as opposed to printing new bar codes at the central warehouse. However, barriers at lower service delivery levels prevented full realization of end-to-end data visibility. Key barriers at the district level were the lack of a digital inventory management system and absence of bar codes at the primary-level packaging level, such as single blister packs. The team in Ethiopia developed an open-sourced smartphone application that allowed the team to scan bar codes using the mobile phone's camera and to push the captured data to the country's data mart. Real-time tracking and tracing occurred from the central warehouse to the Addis Ababa distribution hub and to 2 health centers. These pilots demonstrated that standardized product identification and bar codes can significantly improve accuracy over manual stock counts while significantly streamlining the stock-taking process, resulting in efficiencies. The pilots also showed that bar coding technology by itself is not sufficient to ensure data visibility. Rather, by using global standards for identification and data capture of pharmaceuticals and medical devices, and integrating the data captured into national and global tracking systems

  18. Licensing procedure, nuclear codes and standards in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Schultheiss, G.F.

    1980-01-01

    The present paper deals with legal background of licensing in nuclear technology and atomic energy use, licensing procedures for nuclear power plants and with codes, standards and guidelines in the Federal Republic of Germany. (orig./RW)

  19. Overview on pre-harmonization studies conducted by the Working Group on Codes and Standards

    International Nuclear Information System (INIS)

    Guinovart, J.

    1998-01-01

    For more than twenty years, the Working Group on Codes and Standards (WGCS) has been an Advisory Expert Group of the European Commission and three subgroups were formed to consider manufacture and inspection, structural mechanics and materials topics. The WGCS seeks to promote studies at the pre-harmonisation level, for the clarification and building of consensus in the European Community concerning technical issues of relevance for the integrity of safety-related components. It deals with pre-standardization process regarding industrial codes whose rules are applicable to design, construction and operation of NPP components in European Community

  20. Fifty years of progress in speech coding standards

    Science.gov (United States)

    Cox, Richard

    2004-10-01

    Over the past 50 years, speech coding has taken root worldwide. Early applications were for the military and transmission for telephone networks. The military gave equal priority to intelligibility and low bit rate. The telephone network gave priority to high quality and low delay. These illustrate three of the four areas in which requirements must be set for any speech coder application: bit rate, quality, delay, and complexity. While the military could afford relatively expensive terminal equipment for secure communications, the telephone network needed low cost for massive deployment in switches and transmission equipment worldwide. Today speech coders are at the heart of the wireless phones and telephone answering systems we use every day. In addition to the technology and technical invention that has occurred, standards make it possible for all these different systems to interoperate. The primary areas of standardization are the public switched telephone network, wireless telephony, and secure telephony for government and military applications. With the advent of IP telephony there are additional standardization efforts and challenges. In this talk the progress in all areas is reviewed as well as a reflection on Jim Flanagan's impact on this field during the past half century.

  1. Improving a Power Line Communications Standard with LDPC Codes

    Directory of Open Access Journals (Sweden)

    Hsu Christine

    2007-01-01

    Full Text Available We investigate a power line communications (PLC scheme that could be used to enhance the HomePlug 1.0 standard, specifically its ROBO mode which provides modest throughput for the worst case PLC channel. The scheme is based on using a low-density parity-check (LDPC code, in lieu of the concatenated Reed-Solomon and convolutional codes in ROBO mode. The PLC channel is modeled with multipath fading and Middleton's class A noise. Clipping is introduced to mitigate the effect of impulsive noise. A simple and effective method is devised to estimate the variance of the clipped noise for LDPC decoding. Simulation results show that the proposed scheme outperforms the HomePlug 1.0 ROBO mode and has lower computational complexity. The proposed scheme also dispenses with the repetition of information bits in ROBO mode to gain time diversity, resulting in 4-fold increase in physical layer throughput.

  2. Contributions of the ORNL piping program to nuclear piping design codes and standards

    International Nuclear Information System (INIS)

    Moore, S.E.

    1975-11-01

    The ORNL Piping Program was conceived and established to develop basic information on the structural behavior of nuclear power plant piping components and to prepare this information in forms suitable for use in design analysis and codes and standards. One of the objectives was to develop and qualify stress indices and flexibility factors for direct use in Code-prescribed design analysis methods. Progress in this area is described

  3. The IAEA safety standards

    International Nuclear Information System (INIS)

    Karbassioun, Ahmad

    1995-01-01

    During the development of the NUSS standards, wide consultation was carried out with all the Member States to obtain a consensus and the programme was supervised by a Senior Advisory Group consisting of senior safety experts from 13 countries. This group of senior regulators later became what is now known as the Nuclear Safety Standards Advisory Group (NUSSAG) and comprises of senior regulatory experts from 16 countries. The standards that were developed comprise of four types of documents: safety fundamentals; codes of practice; safety guides; and safety practices. The safety fundamentals set out the basic objectives, concepts and principles for nuclear safety in nuclear power plants. The codes of practice, are of a legislative nature, and establish the general objectives that must be fulfilled to ensure adequate nuclear power plant safety. They cover five areas: governmental organization; siting, design, operation and quality assurance. The safety guides, administrative in character, recommend procedures and acceptable technical solutions to implement the codes and guides by presenting further details gained from Member States, on the application and interpretation of individual concepts in the NUSS codes and guides. In total in the NUSS series there is currently one Fundamentals document, five Codes of Practice and fifty-six Safety Guides

  4. American National Standard administrative practices for nuclear criticality safety, ANSI/ANS-8.19

    International Nuclear Information System (INIS)

    Smith, D.R.; Carson, R.W.

    1991-01-01

    American National Standard Administrative Practices for Nuclear Criticality Safety, ANSI/ANS-8.19, provides guidance for the administration of an effective program to control the risk of nuclear criticality in operations with fissile material outside reactors. The several sections of the standard address the responsibilities of management, supervisory personnel, and the criticality safety staff, as well as requirements and suggestions for the content of operating procedures, process evaluations, material control procedures, and emergency procedures

  5. Software Certification - Coding, Code, and Coders

    Science.gov (United States)

    Havelund, Klaus; Holzmann, Gerard J.

    2011-01-01

    We describe a certification approach for software development that has been adopted at our organization. JPL develops robotic spacecraft for the exploration of the solar system. The flight software that controls these spacecraft is considered to be mission critical. We argue that the goal of a software certification process cannot be the development of "perfect" software, i.e., software that can be formally proven to be correct under all imaginable and unimaginable circumstances. More realistically, the goal is to guarantee a software development process that is conducted by knowledgeable engineers, who follow generally accepted procedures to control known risks, while meeting agreed upon standards of workmanship. We target three specific issues that must be addressed in such a certification procedure: the coding process, the code that is developed, and the skills of the coders. The coding process is driven by standards (e.g., a coding standard) and tools. The code is mechanically checked against the standard with the help of state-of-the-art static source code analyzers. The coders, finally, are certified in on-site training courses that include formal exams.

  6. 77 FR 54836 - Federal Motor Vehicle Safety Standards

    Science.gov (United States)

    2012-09-06

    ... DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration 49 CFR Part 571 Federal Motor Vehicle Safety Standards CFR Correction 0 In Title 49 of the Code of Federal Regulations... read as follows: Sec. 571.119 Standard No. 119; New pneumatic tires for motor vehicles with a GVWR of...

  7. Changing priorities of codes and standards -- quality engineering: Experiences in plant construction, maintenance, and operation

    International Nuclear Information System (INIS)

    Antony, D.D.; Suleski, P.F.; Meier, J.C.

    1994-01-01

    Application of the ASME Code across various fossil and nuclear plants necessitates a Company approach adapted by unique status of each plant. This arises from State Statutes, Federal Regulations and consideration of each plant's as-built history over a broad time frame of design, construction and operation. Additionally, the National Board Inspection Code accompanies Minnesota Statutes for plants owned by Northern States Power Company. This paper addresses some key points on NSP's use of ASME Code as a principal mechanical standard in plant design, construction and operation. A primary resource facilitating review of Code provisions is accurate status on current plant configuration. As plant design changes arise, the Code Edition/Addenda of original construction and installed upgrades or replacements are considered against available options allowed by current standards and dialog with the Jurisdictional Authority. Consistent with the overall goal of safe and reliable plant operation, there are numerous Code details and future needs to be addressed in concert with expected plant economics and planned outages for implementation. The discussion begins in the late 60's with new construction of Monticello and Prairie Island (both nuclear), through Sherburne County Units 1 through 3 (fossil), and their changes, replacements or repairs as operating plants

  8. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1997-01-01

    A method is described for generating electron cross sections that are comparable with standard discrete ordinates codes without modification. There are many advantages of using an established discrete ordinates solver, e.g. immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and man-made radiation environments. The cross sections have been successfully used in the DORT, TWODANT and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electron-photon transport problems. The key to the method is a simultaneous solution of the continuous-slowing-down (CSD) portion and elastic-scattering portion of the scattering source by the Goudsmit-Saunderson theory. The resulting multigroup-Legendre cross sections are much smaller than the true scattering cross sections that they represent. Under certain conditions, the cross sections are guaranteed positive and converge with a low-order Legendre expansion

  9. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1997-01-01

    A method is described for generating electron cross sections that are compatible with standard discrete ordinates codes without modification. There are many advantages to using an established discrete ordinates solver, e.g., immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and synthetic radiation environments. The cross sections have been successfully used in the DORT, TWODANT, and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electron-photon transport problems. The key to the method is a simultaneous solution of the continuous-slowing-down and elastic-scattering portions of the scattering source by the Goudsmit-Saunderson theory. The resulting multigroup-Legendre cross sections are much smaller than the true scattering cross sections that they represent. Under certain conditions, the cross sections are guaranteed positive and converge with a low-order Legendre expansion

  10. Validation of the assert subchannel code: Prediction of CHF in standard and non-standard Candu bundle geometries

    International Nuclear Information System (INIS)

    Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.

    1993-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of prediting CHF at these local conditions, makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries

  11. High efficiency video coding coding tools and specification

    CERN Document Server

    Wien, Mathias

    2015-01-01

    The video coding standard High Efficiency Video Coding (HEVC) targets at improved compression performance for video resolutions of HD and beyond, providing Ultra HD video at similar compressed bit rates as for HD video encoded with the well-established video coding standard H.264 | AVC. Based on known concepts, new coding structures and improved coding tools have been developed and specified in HEVC. The standard is expected to be taken up easily by established industry as well as new endeavors, answering the needs of todays connected and ever-evolving online world. This book presents the High Efficiency Video Coding standard and explains it in a clear and coherent language. It provides a comprehensive and consistently written description, all of a piece. The book targets at both, newbies to video coding as well as experts in the field. While providing sections with introductory text for the beginner, it suits as a well-arranged reference book for the expert. The book provides a comprehensive reference for th...

  12. Ongoing Development of Land Administration Standards : Blockchain in Transaction Management

    NARCIS (Netherlands)

    Lemmen, C.H.J.; Vos, J.; Beentjes, B.

    2017-01-01

    This article in the special edition on blockchain and land transfer in the European Property Law Journal (EPLJ) discusses available standards in land administration and options for further standardisation, including standardisation of transactions of those rights, as a possible first step to

  13. Coding in Muscle Disease.

    Science.gov (United States)

    Jones, Lyell K; Ney, John P

    2016-12-01

    Accurate coding is critically important for clinical practice and research. Ongoing changes to diagnostic and billing codes require the clinician to stay abreast of coding updates. Payment for health care services, data sets for health services research, and reporting for medical quality improvement all require accurate administrative coding. This article provides an overview of administrative coding for patients with muscle disease and includes a case-based review of diagnostic and Evaluation and Management (E/M) coding principles in patients with myopathy. Procedural coding for electrodiagnostic studies and neuromuscular ultrasound is also reviewed.

  14. 45 CFR Appendix B to Part 73 - Code of Ethics for Government Service

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Code of Ethics for Government Service B Appendix B to Part 73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION STANDARDS OF CONDUCT Pt. 73, App. B Appendix B to Part 73—Code of Ethics for Government Service Any person in...

  15. End-of-life decisions in Malaysia: Adequacies of ethical codes and developing legal standards.

    Science.gov (United States)

    Kassim, Puteri Nemie Jahn; Alias, Fadhlina

    2015-06-01

    End-of-life decision-making is an area of medical practice in which ethical dilemmas and legal interventions have become increasingly prevalent. Decisions are no longer confined to clinical assessments; rather, they involve wider considerations such as a patient's religious and cultural beliefs, financial constraints, and the wishes and needs of family members. These decisions affect everyone concerned, including members of the community as a whole. Therefore it is imperative that clear ethical codes and legal standards are developed to help guide the medical profession on the best possible course of action for patients. This article considers the relevant ethical, codes and legal provisions in Malaysia governing certain aspects of end-of-life decision-making. It highlights the lack of judicial decisions in this area as well as the limitations with the Malaysian regulatory system. The article recommends the development of comprehensive ethical codes and legal standards to guide end-of-life decision-making in Malaysia.

  16. Electronic health record standards, coding systems, frameworks, and infrastructures

    CERN Document Server

    Sinha, Pradeep K; Bendale, Prashant; Mantri, Manisha; Dande, Atreya

    2013-01-01

    Discover How Electronic Health Records Are Built to Drive the Next Generation of Healthcare Delivery The increased role of IT in the healthcare sector has led to the coining of a new phrase ""health informatics,"" which deals with the use of IT for better healthcare services. Health informatics applications often involve maintaining the health records of individuals, in digital form, which is referred to as an Electronic Health Record (EHR). Building and implementing an EHR infrastructure requires an understanding of healthcare standards, coding systems, and frameworks. This book provides an

  17. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  18. Adapting Canada's northern infrastructure to climate change: the role of codes and standards

    International Nuclear Information System (INIS)

    Steenhof, P.

    2009-01-01

    This report provides the results of a research project that investigated the use of codes and standards in terms of their potential for fostering adaptation to the future impacts of climate change on built infrastructure in Canada's north. This involved a literature review, undertaking key informant interviews, and a workshop where key stakeholders came together to dialogue on the challenges facing built infrastructure in the north as a result of climate change and the role of codes and standards to help mitigate climate change risk. In this article, attention is given to the topic area of climate data and information requirements related to climate and climate change. This was an important focal area that was identified through this broader research effort since adequate data is essential in allowing codes and standards to meet their ultimate policy objective. A number of priorities have been identified specific to data and information needs in the context of the research topic investigated: There is a need to include northerners in developing the climate and permafrost data required for codes and standards so that these reflect the unique geographical, economic, and cultural realities and variability of the north; Efforts should be undertaken to realign climate design values so that they reflect both present and future risks; There is a need for better information on the rate and extent of permafrost degradation in the north; and, There is a need to improve monitoring of the rate of climate change in the Arctic. (author)

  19. Comparing Sport Coaches' and Administrators' Perceptions of the National Standards for Sport Coaches

    Science.gov (United States)

    Hedlund, David P.; Fletcher, Carol A.; Dahlin, Sean

    2018-01-01

    The purpose of this study was to examine perceptions of sport coaches and administrators regarding the eight domains and 40 standards contained in the National Standards for Sport Coaches (NSSC). Data were primarily obtained from junior high school, high school, and college-level sport coaches (n = 308) and sport administrators (n = 99) in the…

  20. 42 CFR 403.812 - HIPAA privacy, security, administrative data standards, and national identifiers.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false HIPAA privacy, security, administrative data... Prescription Drug Discount Card and Transitional Assistance Program § 403.812 HIPAA privacy, security, administrative data standards, and national identifiers. (a) HIPAA covered entities. An endorsed sponsor is a...

  1. Design validation of the ITER EC upper launcher according to codes and standards

    Energy Technology Data Exchange (ETDEWEB)

    Spaeh, Peter, E-mail: peter.spaeh@kit.edu [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Aiello, Gaetano [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Gagliardi, Mario [Karlsruhe Institute of Technology, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); F4E, Fusion for Energy, Joint Undertaking, Barcelona (Spain); Grossetti, Giovanni; Meier, Andreas; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro [Karlsruhe Institute of Technology, Institute for Applied Materials, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany); Weinhorst, Bastian [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology, Association KIT-EURATOM, P.O. Box 3640, D-76021 Karlsruhe (Germany)

    2015-10-15

    Highlights: • A set of applicable codes and standards has been chosen for the ITER EC upper launcher. • For a particular component load combinations, failure modes and stress categorizations have been determined. • The design validation was performed in accordance with the “design by analysis”-approach of the ASME boiler and pressure vessel code section III. - Abstract: The ITER electron cyclotron (EC) upper launcher has passed the CDR (conceptual design review) in 2005 and the PDR (preliminary design review) in 2009 and is in its final design phase now. The final design will be elaborated by the European consortium ECHUL-CA with contributions from several research institutes in Germany, Italy, the Netherlands and Switzerland. Within this consortium KIT is responsible for the design of the structural components (the upper port plug, UPP) and also the design integration of the launcher. As the selection of applicable codes and standards was under discussion for the past decade, the conceptual and the preliminary design of the launcher structure were not elaborated in straight accordance with a particular code but with a variety of well-acknowledged engineering practices. For the final design it is compulsory to validate the design with respect to a typical engineering code in order to be compliant with the ITER quality and nuclear requirements and to get acceptance from the French regulator. This paper presents typical design validation of the closure plate, which is the vacuum and Tritium barrier and thus a safety relevant component of the upper port plug (UPP), performed with the ASME boiler and pressure vessel code. Rationales for choosing this code are given as well as a comparison between different design methods, like the “design by rule” and the “design by analysis” approach. Also the selections of proper load specifications and the identification of potential failure modes are covered. In addition to that stress categorizations, analyses

  2. Design validation of the ITER EC upper launcher according to codes and standards

    International Nuclear Information System (INIS)

    Spaeh, Peter; Aiello, Gaetano; Gagliardi, Mario; Grossetti, Giovanni; Meier, Andreas; Scherer, Theo; Schreck, Sabine; Strauss, Dirk; Vaccaro, Alessandro; Weinhorst, Bastian

    2015-01-01

    Highlights: • A set of applicable codes and standards has been chosen for the ITER EC upper launcher. • For a particular component load combinations, failure modes and stress categorizations have been determined. • The design validation was performed in accordance with the “design by analysis”-approach of the ASME boiler and pressure vessel code section III. - Abstract: The ITER electron cyclotron (EC) upper launcher has passed the CDR (conceptual design review) in 2005 and the PDR (preliminary design review) in 2009 and is in its final design phase now. The final design will be elaborated by the European consortium ECHUL-CA with contributions from several research institutes in Germany, Italy, the Netherlands and Switzerland. Within this consortium KIT is responsible for the design of the structural components (the upper port plug, UPP) and also the design integration of the launcher. As the selection of applicable codes and standards was under discussion for the past decade, the conceptual and the preliminary design of the launcher structure were not elaborated in straight accordance with a particular code but with a variety of well-acknowledged engineering practices. For the final design it is compulsory to validate the design with respect to a typical engineering code in order to be compliant with the ITER quality and nuclear requirements and to get acceptance from the French regulator. This paper presents typical design validation of the closure plate, which is the vacuum and Tritium barrier and thus a safety relevant component of the upper port plug (UPP), performed with the ASME boiler and pressure vessel code. Rationales for choosing this code are given as well as a comparison between different design methods, like the “design by rule” and the “design by analysis” approach. Also the selections of proper load specifications and the identification of potential failure modes are covered. In addition to that stress categorizations, analyses

  3. Validation of the ASSERT subchannel code for prediction of CHF in standard and non-standard CANDU bundle geometries

    International Nuclear Information System (INIS)

    Kiteley, J.C.; Carver, M.B.; Zhou, Q.N.

    1993-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting critical heat flux (CHF) at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is the only tool available to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries. 28 refs., 12 figs

  4. Analyses in Support of Risk-Informed Natural Gas Vehicle Maintenance Facility Codes and Standards: Phase II.

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, Myra L.; LaFleur, Chris Bensdotter; Muna, Alice Baca; Ehrhart, Brian David

    2018-03-01

    Safety standards development for maintenance facilities of liquid and compressed natural gas fueled vehicles is required to ensure proper facility design and operating procedures. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase II work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest using risk ranking. Detailed simulations and modeling were performed to estimate the location and behavior of natural gas releases based on these scenarios. Specific code conflicts were identified, and ineffective code requirements were highlighted and resolutions proposed. These include ventilation rate basis on area or volume, as well as a ceiling offset which seems ineffective at protecting against flammable gas concentrations. ACKNOWLEDGEMENTS The authors gratefully acknowledge Bill Houf (SNL -- Retired) for his assistance with the set-up and post-processing of the numerical simulations. The authors also acknowledge Doug Horne (retired) for his helpful discussions. We would also like to acknowledge the support from the Clean Cities program of DOE's Vehicle Technology Office.

  5. Administrative goals and safety standards for hazard control on forested recreation sites

    Science.gov (United States)

    Lee A. Paine

    1973-01-01

    For efficient control of tree hazard on recreation sites, a specific administrative goal must be selected. A safety standard designed to achieve the selected goal and a uniform hazard-rating procedure will then promote a consistent level of safety at an acceptable cost. Safety standards can be established with the aid of data for past years, and dollar evaluations are...

  6. 77 FR 72691 - Small Business Size Standards: Administrative and Support, Waste Management and Remediation Services

    Science.gov (United States)

    2012-12-06

    ... importantly, the Small Business Act requires SBA to establish one definition of what is a small business... SMALL BUSINESS ADMINISTRATION 13 CFR Part 121 RIN 3245-AG27 Small Business Size Standards: Administrative and Support, Waste Management and Remediation Services AGENCY: U.S. Small Business Administration...

  7. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  8. High-Penetration Photovoltaics Standards and Codes Workshop, Denver, Colorado, May 20, 2010: Workshop Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Kroposki, B.; Basso, T.; Lynn, K.; Herig, C.; Bower, W.

    2010-09-01

    Effectively interconnecting high-level penetration of photovoltaic (PV) systems requires careful technical attention to ensuring compatibility with electric power systems. Standards, codes, and implementation have been cited as major impediments to widespread use of PV within electric power systems. On May 20, 2010, in Denver, Colorado, the National Renewable Energy Laboratory, in conjunction with the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), held a workshop to examine the key technical issues and barriers associated with high PV penetration levels with an emphasis on codes and standards. This workshop included building upon results of the High Penetration of Photovoltaic (PV) Systems into the Distribution Grid workshop held in Ontario California on February 24-25, 2009, and upon the stimulating presentations of the diverse stakeholder presentations.

  9. The Teaching of the Code of Ethics and Standard Practices for Texas Educator Preparation Programs

    Science.gov (United States)

    Davenport, Marvin; Thompson, J. Ray; Templeton, Nathan R.

    2015-01-01

    The purpose of this descriptive quantitative research study was to answer three basic informational questions: (1) To what extent ethics training, as stipulated in Texas Administrative Code Chapter 247, was included in the EPP curriculum; (2) To what extent Texas public universities with approved EPP programs provided faculty opportunities for…

  10. Japanese standard method for safety evaluation using best estimate code based on uncertainty and scaling analyses with statistical approach

    International Nuclear Information System (INIS)

    Mizokami, Shinya; Hotta, Akitoshi; Kudo, Yoshiro; Yonehara, Tadashi; Watada, Masayuki; Sakaba, Hiroshi

    2009-01-01

    Current licensing practice in Japan consists of using conservative boundary and initial conditions(BIC), assumptions and analytical codes. The safety analyses for licensing purpose are inherently deterministic. Therefore, conservative BIC and assumptions, such as single failure, must be employed for the analyses. However, using conservative analytical codes are not considered essential. The standard committee of Atomic Energy Society of Japan(AESJ) has drawn up the standard for using best estimate codes for safety analyses in 2008 after three-years of discussions reflecting domestic and international recent findings. (author)

  11. Fundamental challenging problems for developing new nuclear safety standard computer codes

    International Nuclear Information System (INIS)

    Wong, P.K.; Wong, A.E.; Wong, A.

    2005-01-01

    Based on the claims of the US Basic patents number 5,084,232; 5,848,377 and 6,430,516 that can be obtained from typing the Patent Numbers into the Box of the Web site http://164.195.100.11/netahtml/srchnum.htm and their associated published technical papers having been presented and published at International Conferences in the last three years and that all these had been sent into US-NRC by E-mail on March 26, 2003 at 2:46 PM., three fundamental challenging problems for developing new nuclear safety standard computer codes had been presented at the US-NRC RIC2003 Session W4. 2:15-3:15 PM. at the Washington D.C. Capital Hilton Hotel, Presidential Ballroom on April 16, 2003 in front of more than 800 nuclear professionals from many countries worldwide. The objective and scope of this paper is to invite all nuclear professionals to examine and evaluate all the current computer codes being used in their own countries by means of comparison of numerical data from these three specific openly challenging fundamental problems in order to set up a global safety standard for all nuclear power plants in the world. (authors)

  12. MDEP Technical Report TR-CSWG-01. Technical Report: Regulatory Frameworks for the Use of Nuclear Pressure Boundary Codes and Standards in MDEP Countries

    International Nuclear Information System (INIS)

    2013-01-01

    The Codes and Standards Working Group (CSWG) is one of the issue-specific working groups that the MDEP members are undertaking; its long term goal is harmonisation of regulatory and code requirements for design and construction of pressure-retaining components in order to improve the effectiveness and efficiency of the regulatory design reviews, increase quality of safety assessments, and to enable each regulator to become stronger in its ability to make safety decisions. The CSWG has interacted closely with the Standards Development Organisations (SDOs) and CORDEL in code comparison and code convergence. The Code Comparison Report STP-NU-051 has been issued by SDO members to identify the extent of similarities and differences amongst the pressure-boundary codes and standards used in various countries. Besides the differences in codes and standards, the way how the codes and standards are applied to systems, structures and components also affects the design and construction of nuclear power plant. Therefore, to accomplish the goal of potential harmonisation, it is also vital that the regulators learn about each other's procedures, processes, and regulations. To facilitate the learning process, the CSWG meets regularly to discuss issues relevant to licensing new reactors and using codes and standards in licensing safety reviews. The CSWG communicates very frequently with the SDOs to discuss similarities and differences among the various codes and how to proceed with potential harmonisation. It should be noted that the IAEA is invited to all of the issue-specific working groups within MDEP to ensure consistency with IAEA standards. The primary focus of this technical report is to consolidate information shared and accomplishments achieved by the member countries. This report seeks to document how each MDEP regulator utilises national or regional mechanical codes and standards in its safety reviews and licensing of new reactors. The preparation of this report

  13. Non-standard model for electron heat transport for multidimensional hydrodynamic codes

    Energy Technology Data Exchange (ETDEWEB)

    Nicolai, Ph.; Busquet, M.; Schurtz, G. [CEA/DAM-Ile de France, 91 - Bruyeres Le Chatel (France)

    2000-07-01

    In simulations of laser-produced plasma, modeling of heat transport requires an artificial limitation of standard Spitzer-Haerm fluxes. To improve heat conduction processing, we have developed a multidimensional model which accounts for non-local features of heat transport and effects of self-generated magnetic fields. This consistent treatment of both mechanisms has been implemented in a two-dimensional radiation-hydrodynamic code. First results indicate good agreements between simulations and experimental data. (authors)

  14. Non-standard model for electron heat transport for multidimensional hydrodynamic codes

    International Nuclear Information System (INIS)

    Nicolai, Ph.; Busquet, M.; Schurtz, G.

    2000-01-01

    In simulations of laser-produced plasma, modeling of heat transport requires an artificial limitation of standard Spitzer-Haerm fluxes. To improve heat conduction processing, we have developed a multidimensional model which accounts for non-local features of heat transport and effects of self-generated magnetic fields. This consistent treatment of both mechanisms has been implemented in a two-dimensional radiation-hydrodynamic code. First results indicate good agreements between simulations and experimental data. (authors)

  15. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    DEFF Research Database (Denmark)

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...

  16. Biases in detection of apparent "weekend effect" on outcome with administrative coding data: population based study of stroke.

    Science.gov (United States)

    Li, Linxin; Rothwell, Peter M

    2016-05-16

     To determine the accuracy of coding of admissions for stroke on weekdays versus weekends and any impact on apparent outcome.  Prospective population based stroke incidence study and a scoping review of previous studies of weekend effects in stroke.  Primary and secondary care of all individuals registered with nine general practices in Oxfordshire, United Kingdom (OXVASC, the Oxford Vascular Study).  All patients with clinically confirmed acute stroke in OXVASC identified with multiple overlapping methods of ascertainment in 2002-14 versus all acute stroke admissions identified by hospital diagnostic and mortality coding alone during the same period.  Accuracy of administrative coding data for all patients with confirmed stroke admitted to hospital in OXVASC. Difference between rates of "false positive" or "false negative" coding for weekday and weekend admissions. Impact of inaccurate coding on apparent case fatality at 30 days in weekday versus weekend admissions. Weekend effects on outcomes in patients with confirmed stroke admitted to hospital in OXVASC and impacts of other potential biases compared with those in the scoping review.  Among 92 728 study population, 2373 episodes of acute stroke were ascertained in OXVASC, of which 826 (34.8%) mainly minor events were managed without hospital admission, 60 (2.5%) occurred out of the area or abroad, and 195 (8.2%) occurred in hospital during an admission for a different reason. Of 1292 local hospital admissions for acute stroke, 973 (75.3%) were correctly identified by administrative coding. There was no bias in distribution of weekend versus weekday admission of the 319 strokes missed by coding. Of 1693 admissions for stroke identified by coding, 1055 (62.3%) were confirmed to be acute strokes after case adjudication. Among the 638 false positive coded cases, patients were more likely to be admitted on weekdays than at weekends (536 (41.0%) v 102 (26.5%); Pcoded acute stroke admissions and false positive

  17. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1993-01-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes

  18. 49 CFR 41.120 - Acceptable model codes.

    Science.gov (United States)

    2010-10-01

    ... 1991 International Conference of Building Officials (ICBO) Uniform Building Code, published by the... Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code, published by the Building Officials and Code Administrators, 4051 West Flossmoor Rd., Country Club Hills...

  19. 75 FR 66725 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards

    Science.gov (United States)

    2010-10-29

    ... for Solvent 5/23/2011 Extraction Plants. NFPA 51--2007 Standard for the Design and 11/23/2010... Practice for a 5/23/2011 Field Flame Test for Textiles and Films. NFPA 909--2010 Code for the Protection of...

  20. Review of application code and standards for mechanical and piping design of HANARO fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.

    1998-02-01

    The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the propriety of application code and standards for mechanical and piping of HANARO fuel test loop and to decide the technical specification of FTL systems. (author). 18 refs., 8 tabs., 6 figs.

  1. Validation of coding algorithms for the identification of patients hospitalized for alcoholic hepatitis using administrative data.

    Science.gov (United States)

    Pang, Jack X Q; Ross, Erin; Borman, Meredith A; Zimmer, Scott; Kaplan, Gilaad G; Heitman, Steven J; Swain, Mark G; Burak, Kelly W; Quan, Hude; Myers, Robert P

    2015-09-11

    Epidemiologic studies of alcoholic hepatitis (AH) have been hindered by the lack of a validated International Classification of Disease (ICD) coding algorithm for use with administrative data. Our objective was to validate coding algorithms for AH using a hospitalization database. The Hospital Discharge Abstract Database (DAD) was used to identify consecutive adults (≥18 years) hospitalized in the Calgary region with a diagnosis code for AH (ICD-10, K70.1) between 01/2008 and 08/2012. Medical records were reviewed to confirm the diagnosis of AH, defined as a history of heavy alcohol consumption, elevated AST and/or ALT (34 μmol/L, and elevated INR. Subgroup analyses were performed according to the diagnosis field in which the code was recorded (primary vs. secondary) and AH severity. Algorithms that incorporated ICD-10 codes for cirrhosis and its complications were also examined. Of 228 potential AH cases, 122 patients had confirmed AH, corresponding to a positive predictive value (PPV) of 54% (95% CI 47-60%). PPV improved when AH was the primary versus a secondary diagnosis (67% vs. 21%; P codes for ascites (PPV 75%; 95% CI 63-86%), cirrhosis (PPV 60%; 47-73%), and gastrointestinal hemorrhage (PPV 62%; 51-73%) had improved performance, however, the prevalence of these diagnoses in confirmed AH cases was low (29-39%). In conclusion the low PPV of the diagnosis code for AH suggests that caution is necessary if this hospitalization database is used in large-scale epidemiologic studies of this condition.

  2. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, M. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

  3. Former Yugoslav Republic of Macedonia; Report on Observance of Standards and Codes: Fiscal Transparency Module

    OpenAIRE

    International Monetary Fund

    2006-01-01

    This report summarizes the Observance of Standards and Codes on Fiscal Transparency for the Former Yugoslav Republic of Macedonia. It provides an assessment of fiscal transparency practices in the Former Yugoslav Republic (FYR) of Macedonia in relation to the requirements of the IMF Code of Good Practices on Fiscal Transparency based on discussions with the authorities and other organizations and through a fiscal transparency questionnaire. It also provides recommendations for improving fisca...

  4. SRAC: JAERI thermal reactor standard code system for reactor design and analysis

    International Nuclear Information System (INIS)

    Tsuchihashi, Keichiro; Takano, Hideki; Horikami, Kunihiko; Ishiguro, Yukio; Kaneko, Kunio; Hara, Toshiharu.

    1983-01-01

    The SRAC (Standard Reactor Analysis Code) is a code system for nuclear reactor analysis and design. It is composed of neutron cross section libraries and auxiliary processing codes, neutron spectrum routines, a variety of transport, 1-, 2- and 3-D diffusion routines, dynamic parameters and cell burn-up routines. By making the best use of the individual code function in the SRAC system, the user can select either the exact method for an accurate estimate of reactor characteristics or the economical method aiming at a shorter computer time, depending on the purpose of study. The user can select cell or core calculation; fixed source or eigenvalue problem; transport (collision probability or Sn) theory or diffusion theory. Moreover, smearing and collapsing of macroscopic cross sections are separately done by the user's selection. And a special attention is paid for double heterogeneity. Various techniques are employed to access the data storage and to optimize the internal data transfer. Benchmark calculations using the SRAC system have been made extensively for the Keff values of various types of critical assemblies (light water, heavy water and graphite moderated systems, and fast reactor systems). The calculated results show good prediction for the experimental Keff values. (author)

  5. Cape Verde Report on the Observance of Standards and Codes : Accounting and Auditing

    OpenAIRE

    World Bank

    2012-01-01

    This Report on the Observance of Standards and Codes (ROSC) provides an assessment of the strengths and weaknesses of the existing financial reporting infrastructure that underpins financial accounting and auditing practices in Cape Verde. The assessment focuses on six pillars of financial reporting infrastructure: statutory framework, professional education and training, accountancy profe...

  6. 76 FR 70413 - National Fire Protection Association (NFPA): Request for Comments on NFPA's Codes and Standards

    Science.gov (United States)

    2011-11-14

    ... Private Fire Protection. P NFPA 36 Standard for Solvent Extraction Plants P NFPA 52 Vehicular Gaseous Fuel Systems Code P NFPA 67 Guideline on Explosion Protection for Gaseous N Mixtures in Pipe Systems. NFPA 68 Standard on Explosion Protection by Deflagration P Venting. NFPA 70B Recommended Practice for Electrical...

  7. Error detecting capabilities of the shortened Hamming codes adopted for error detection in IEEE Standard 802.3

    Science.gov (United States)

    Fujiwara, Toru; Kasami, Tadao; Lin, Shu

    1989-09-01

    The error-detecting capabilities of the shortened Hamming codes adopted for error detection in IEEE Standard 802.3 are investigated. These codes are also used for error detection in the data link layer of the Ethernet, a local area network. The weight distributions for various code lengths are calculated to obtain the probability of undetectable error and that of detectable error for a binary symmetric channel with bit-error rate between 0.00001 and 1/2.

  8. Recommendations for codes and standards to be used for design and fabrication of high level waste canister

    International Nuclear Information System (INIS)

    Bermingham, A.J.; Booker, R.J.; Booth, H.R.; Ruehle, W.G.; Shevekov, S.; Silvester, A.G.; Tagart, S.W.; Thomas, J.A.; West, R.G.

    1978-01-01

    This study identifies codes, standards, and regulatory requirements for developing design criteria for high-level waste (HLW) canisters for commercial operation. It has been determined that the canister should be designed as a pressure vessel without provision for any overpressure protection type devices. It is recommended that the HLW canister be designed and fabricated to the requirements of the ASME Section III Code, Division 1 rules, for Code Class 3 components. Identification of other applicable industry and regulatory guides and standards are provided in this report. Requirements for the Design Specification are found in the ASME Section III Code. It is recommended that design verification be conducted principally with prototype testing which will encompass normal and accident service conditions during all phases of the canister life. Adequacy of existing quality assurance and licensing standards for the canister was investigated. One of the recommendations derived from this study is a requirement that the canister be N stamped. In addition, acceptance standards for the HLW waste should be established and the waste qualified to those standards before the canister is sealed. A preliminary investigation of use of an overpack for the canister has been made, and it is concluded that the use of an overpack, as an integral part of overall canister design, is undesirable, both from a design and economics standpoint. However, use of shipping cask liners and overpack type containers at the Federal repository may make the canister and HLW management safer and more cost effective. There are several possible concepts for canister closure design. These concepts can be adapted to the canister with or without an overpack. A remote seal weld closure is considered to be one of the most suitable closure methods; however, mechanical seals should also be investigated

  9. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files

  10. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files.

  11. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1987-05-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes

  12. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1983-10-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience

  13. Biases in detection of apparent “weekend effect” on outcome with administrative coding data: population based study of stroke

    Science.gov (United States)

    Li, Linxin

    2016-01-01

    Objectives To determine the accuracy of coding of admissions for stroke on weekdays versus weekends and any impact on apparent outcome. Design Prospective population based stroke incidence study and a scoping review of previous studies of weekend effects in stroke. Setting Primary and secondary care of all individuals registered with nine general practices in Oxfordshire, United Kingdom (OXVASC, the Oxford Vascular Study). Participants All patients with clinically confirmed acute stroke in OXVASC identified with multiple overlapping methods of ascertainment in 2002-14 versus all acute stroke admissions identified by hospital diagnostic and mortality coding alone during the same period. Main outcomes measures Accuracy of administrative coding data for all patients with confirmed stroke admitted to hospital in OXVASC. Difference between rates of “false positive” or “false negative” coding for weekday and weekend admissions. Impact of inaccurate coding on apparent case fatality at 30 days in weekday versus weekend admissions. Weekend effects on outcomes in patients with confirmed stroke admitted to hospital in OXVASC and impacts of other potential biases compared with those in the scoping review. Results Among 92 728 study population, 2373 episodes of acute stroke were ascertained in OXVASC, of which 826 (34.8%) mainly minor events were managed without hospital admission, 60 (2.5%) occurred out of the area or abroad, and 195 (8.2%) occurred in hospital during an admission for a different reason. Of 1292 local hospital admissions for acute stroke, 973 (75.3%) were correctly identified by administrative coding. There was no bias in distribution of weekend versus weekday admission of the 319 strokes missed by coding. Of 1693 admissions for stroke identified by coding, 1055 (62.3%) were confirmed to be acute strokes after case adjudication. Among the 638 false positive coded cases, patients were more likely to be admitted on weekdays than at weekends (536

  14. Analysis of the Current Technical Issues on ASME Code and Standard for Nuclear Mechanical Design(2009)

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Lee, B. S.; Yoo, S. H.

    2009-11-01

    This report describes the analysis on the current revision movement related to the mechanical design issues of the U.S ASME nuclear code and standard. ASME nuclear mechanical design in this report is composed of the nuclear material, primary system, secondary system and high temperature reactor. This report includes the countermeasures based on the ASME Code meeting for current issues of each major field. KAMC(ASME Mirror Committee) of this project is willing to reflect a standpoint of the domestic nuclear industry on ASME nuclear mechanical design and play a technical bridge role for the domestic nuclear industry in ASME Codes application

  15. Analysis of the Current Technical Issues on ASME Code and Standard for Nuclear Mechanical Design(2009)

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Gyeong Hoi; Lee, B. S.; Yoo, S. H.

    2009-11-15

    This report describes the analysis on the current revision movement related to the mechanical design issues of the U.S ASME nuclear code and standard. ASME nuclear mechanical design in this report is composed of the nuclear material, primary system, secondary system and high temperature reactor. This report includes the countermeasures based on the ASME Code meeting for current issues of each major field. KAMC(ASME Mirror Committee) of this project is willing to reflect a standpoint of the domestic nuclear industry on ASME nuclear mechanical design and play a technical bridge role for the domestic nuclear industry in ASME Codes application

  16. Variable Coding and Modulation Experiment Using NASA's Space Communication and Navigation Testbed

    Science.gov (United States)

    Downey, Joseph A.; Mortensen, Dale J.; Evans, Michael A.; Tollis, Nicholas S.

    2016-01-01

    National Aeronautics and Space Administration (NASA)'s Space Communication and Navigation Testbed on the International Space Station provides a unique opportunity to evaluate advanced communication techniques in an operational system. The experimental nature of the Testbed allows for rapid demonstrations while using flight hardware in a deployed system within NASA's networks. One example is variable coding and modulation, which is a method to increase data-throughput in a communication link. This paper describes recent flight testing with variable coding and modulation over S-band using a direct-to-earth link between the SCaN Testbed and the Glenn Research Center. The testing leverages the established Digital Video Broadcasting Second Generation (DVB-S2) standard to provide various modulation and coding options. The experiment was conducted in a challenging environment due to the multipath and shadowing caused by the International Space Station structure. Performance of the variable coding and modulation system is evaluated and compared to the capacity of the link, as well as standard NASA waveforms.

  17. Optimizing the electronic health record to standardize administration and documentation of nutritional supplements.

    Science.gov (United States)

    Citty, Sandra W; Kamel, Amir; Garvan, Cynthia; Marlowe, Lee; Westhoff, Lynn

    2017-01-01

    Malnutrition in hospitalized patients is a major cause for hospital re-admission, pressure ulcers and increased hospital costs. Methods to improve the administration and documentation of nutritional supplements for hospitalized patients are needed to improve patient care, outcomes and resource utilization. Staff at a medium-sized academic health science center hospital in the southeastern United States noted that nutritional supplements ordered for patients at high risk for malnutrition were not offered or administered to patients in a standardized manner and/or not documented clearly in the electronic health record as per prescription. This paper reports on a process improvement project that redesigned the ordering, administration and documentation process of oral nutritional supplements in the electronic health record. By adding nutritional products to the medication order sets and adding an electronic nutrition administration record (ENAR) tab, the multidisciplinary team sought to standardize nutritional supplement ordering, documentation and administration at prescribed intervals. This process improvement project used a triangulated approach to evaluating pre- and post-process change including: medical record reviews, patient interviews, and nutrition formula room log reports. Staff education and training was carried out prior to initiation of the system changes. This process change resulted in an average decrease in the return of unused nutritional formula from 76% returned at baseline to 54% post-process change. The process change resulted in 100% of nutritional supplement orders having documentation about nutritional medication administration and/or reason for non-administration. Documentation in the ENAR showed that 41% of ONS orders were given and 59% were not given. Significantly more patients reported being offered the ONS product (p=0.0001) after process redesign and more patients (5% before ENAR and 86% after ENAR reported being offered the correct

  18. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Science.gov (United States)

    2010-04-16

    ... documents from ICC's Chicago District Office: International Code Council, 4051 W Flossmoor Road, Country... Energy Conservation Code. International Existing Building Code. International Fire Code. International...

  19. Advanced video coding systems

    CERN Document Server

    Gao, Wen

    2015-01-01

    This comprehensive and accessible text/reference presents an overview of the state of the art in video coding technology. Specifically, the book introduces the tools of the AVS2 standard, describing how AVS2 can help to achieve a significant improvement in coding efficiency for future video networks and applications by incorporating smarter coding tools such as scene video coding. Topics and features: introduces the basic concepts in video coding, and presents a short history of video coding technology and standards; reviews the coding framework, main coding tools, and syntax structure of AV

  20. International standards: the World Organisation for Animal Health Terrestrial Animal Health Code.

    Science.gov (United States)

    Thiermann, A B

    2015-04-01

    This paper provides a description of the international standards contained in the TerrestrialAnimal Health Code of the World Organisation for Animal Health (OIE) that relate to the prevention and control of vector-borne diseases. It identifies the rights and obligations of OIE Member Countries regarding the notification of animal disease occurrences, as well as the recommendations to be followed for a safe and efficient international trade of animals and their products.

  1. Evaluation on applicability of the rules, regulations, and industrial codes and standards for SMART development

    International Nuclear Information System (INIS)

    Choi, Suhn; Lee, C C.; Lee, C.K.; Kim, K.K.; Kim, J.P.; Kim, J.H.; Cho, B.H.; Kang, D J.; Bae, G.H.; Chung, M.; Chang, M.H.

    1999-03-01

    In this report, evaluation on applicability of the rules, regulations, and industrial codes and standards for SMART has been made. As the first step, past-to-present status of licensing structures were reviewed. Then, the rules, regulations, and standards applied to YGN 3-6 were listed and reviewed. Finally, evaluation on applicability of such rules and standards for SMART are made in each design fields. During this step technical evaluations on each items of rules, regulations and standards are made and the possible remedies or comments are suggested. The results are summarized in a tabular form and enclosed as Appendix. (Author). 8 refs., 5 tabs., 3 figs

  2. Guidelines on Active Content and Mobile Code: Recommendations of the National Institute of Standards and Technology

    National Research Council Canada - National Science Library

    Jansen, Wayne

    2001-01-01

    .... One such category of technologies is active content. Broadly speaking, active content refers to electronic documents that, unlike past character documents based on the American Standard Code for Information Interchange (ASCII...

  3. Entropy Coding in HEVC

    OpenAIRE

    Sze, Vivienne; Marpe, Detlev

    2014-01-01

    Context-Based Adaptive Binary Arithmetic Coding (CABAC) is a method of entropy coding first introduced in H.264/AVC and now used in the latest High Efficiency Video Coding (HEVC) standard. While it provides high coding efficiency, the data dependencies in H.264/AVC CABAC make it challenging to parallelize and thus limit its throughput. Accordingly, during the standardization of entropy coding for HEVC, both aspects of coding efficiency and throughput were considered. This chapter describes th...

  4. Oil and Gas field code master list 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    This is the fourteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1995 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the US. The Field Code Index, a listing of all field names and the States in which they occur, ordered by field code, has been removed from this year`s publications to reduce printing and postage costs. Complete copies (including the Field Code Index) will be available on the EIA CD-ROM and the EIA World-Wide Web Site. Future editions of the complete Master List will be available on CD-ROM and other electronic media. There are 57,400 field records in this year`s Oil and Gas Field Code Master List. As it is maintained by EIA, the Master List includes the following: field records for each State and county in which a field resides; field records for each offshore area block in the Gulf of Mexico in which a field resides; field records for each alias field name (see definition of alias below); and fields crossing State boundaries that may be assigned different names by the respective State naming authorities. Taking into consideration the double-counting of fields under such circumstances, EIA identifies 46,312 distinct fields in the US as of October 1995. This count includes fields that no longer produce oil or gas, and 383 fields used in whole or in part for oil or gas Storage. 11 figs., 6 tabs.

  5. Performance and Complexity Co-evaluation of the Advanced Video Coding Standard for Cost-Effective Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Saponara Sergio

    2004-01-01

    Full Text Available The advanced video codec (AVC standard, recently defined by a joint video team (JVT of ITU-T and ISO/IEC, is introduced in this paper together with its performance and complexity co-evaluation. While the basic framework is similar to the motion-compensated hybrid scheme of previous video coding standards, additional tools improve the compression efficiency at the expense of an increased implementation cost. As a first step to bridge the gap between the algorithmic design of a complex multimedia system and its cost-effective realization, a high-level co-evaluation approach is proposed and applied to a real-life AVC design. An exhaustive analysis of the codec compression efficiency versus complexity (memory and computational costs project space is carried out at the early algorithmic design phase. If all new coding features are used, the improved AVC compression efficiency (up to 50% compared to current video coding technology comes with a complexity increase of a factor 2 for the decoder and larger than one order of magnitude for the encoder. This represents a challenge for resource-constrained multimedia systems such as wireless devices or high-volume consumer electronics. The analysis also highlights important properties of the AVC framework allowing for complexity reduction at the high system level: when combining the new coding features, the implementation complexity accumulates, while the global compression efficiency saturates. Thus, a proper use of the AVC tools maintains the same performance as the most complex configuration while considerably reducing complexity. The reported results provide inputs to assist the profile definition in the standard, highlight the AVC bottlenecks, and select optimal trade-offs between algorithmic performance and complexity.

  6. Stroke code improves intravenous thrombolysis administration in acute ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Chih-Hao Chen

    Full Text Available Timely intravenous (IV thrombolysis for acute ischemic stroke is associated with better clinical outcomes. Acute stroke care implemented with "Stroke Code" (SC may increase IV tissue plasminogen activator (tPA administration. The present study aimed to investigate the impact of SC on thrombolysis.The study period was divided into the "pre-SC era" (January 2006 to July 2010 and "SC era" (August 2010 to July 2013. Demographics, critical times (stroke symptom onset, presentation to the emergency department, neuroimaging, thrombolysis, stroke severity, and clinical outcomes were recorded and compared between the two eras.During the study period, 5957 patients with acute ischemic stroke were admitted; of these, 1301 (21.8% arrived at the emergency department within 3 h of stroke onset and 307 (5.2% received IV-tPA. The number and frequency of IV-tPA treatments for patients with an onset-to-door time of <3 h increased from the pre-SC era (n = 91, 13.9% to the SC era (n = 216, 33.3% (P<0.001. SC also improved the efficiency of IV-tPA administration; the median door-to-needle time decreased (88 to 51 min, P<0.001 and the percentage of door-to-needle times ≤60 min increased (14.3% to 71.3%, P<0.001. The SC era group tended to have more patients with good outcome (modified Rankin Scale ≤2 at discharge (49.5 vs. 39.6%, P = 0.11, with no difference in symptomatic hemorrhage events or in-hospital mortality.The SC protocol increases the percentage of acute ischemic stroke patients receiving IV-tPA and decreases door-to-needle time.

  7. Methodological Study to Develop Standard Operational Protocol on Oral Drug Administration for Children.

    Science.gov (United States)

    Bijarania, Sunil Kumar; Saini, Sushma Kumari; Verma, Sanjay; Kaur, Sukhwinder

    2017-05-01

    To develop standard operational protocol (SOP) on oral drug administration and checklist to assess the implementation of the developed SOP. In this prospective methodological study, SOPs were developed in five phases. In the first phase, the preliminary draft of SOPs and checklists were prepared based on literature review, assessment of current practices and focus group discussion (FGD) with bedside working nurses. In the second phase, content validity was checked with the help of Delphi technique (12 experts). Total four drafts were prepared in stages and necessary modifications were made as per suggestions after each Delphi round. Fourth Delphi round was performed after conducting a pilot study. In the fourth phase, all bedside nurses were trained as per SOPs and asked to practice accordingly and observation of thirty oral drug administrations in children was done to check reliability of checklists for implementation of SOPs. In Phase-V, 7 FGDs were conducted with bedside nurses to assess the effectiveness of SOPs. The Content Validity Index (CVI) of SOP and checklists was 99.77%. Overall standardized Cronbach's alpha was calculated as 0.94. All the nurses felt that the SOP is useful. Valid and feasible SOP for drug administration to children through oral route along with valid and reliable checklist were developed. It is recommended to use this document for drug administration to children.

  8. Turbo-Gallager Codes: The Emergence of an Intelligent Coding ...

    African Journals Online (AJOL)

    Today, both turbo codes and low-density parity-check codes are largely superior to other code families and are being used in an increasing number of modern communication systems including 3G standards, satellite and deep space communications. However, the two codes have certain distinctive characteristics that ...

  9. The applicability of ALPHA/PHOENIX/ANC nuclear design code system on Korean standard PWR's

    International Nuclear Information System (INIS)

    Lee, Kookjong; Choi, Kie-Yong; Lee, Hae-Chan; Roh, Eun-Rae

    1996-01-01

    For the Korean Standard Nuclear Power Plant (KSNPP) designed based on Combustion Engineering (CE) System 80, the Westinghouse nuclear design code system ALPHA/PHOENIX/ANC was applied to the follow-up design of initial and reload core of KSNPP. The follow-up design results of Yonggwang Unit 3 Cycle 1, 2 and Yonggwang Unit 4 Cycle 1 have shown good agreements with the measured data. The assemblywise power distributions have shown less than 2% average differences and critical boron concentrations have shown less than 20 ppm differences. All the low power physics test parameters are in good agreement. Consequently, APA design code system can be applied to KNSPP cores. (author)

  10. Integrating industry nuclear codes and standards into United States Department of Energy facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jacox, J.

    1995-02-01

    Recently the United States Department of Energy (DOE) has mandated facilities under their jurisdiction use various industry Codes and Standards developed for civilian power reactors that operate under U.S. Nuclear Regulatory Commission License. While this is a major step forward in putting all our nuclear facilities under common technical standards there are always problems associated with implementing such advances. This paper will discuss some of the advantages and problems experienced to date. These include the universal challenge of educating new users of any technical documents, repeating errors made by the NRC licensed facilities over the years and some unique problems specific to DOE facilities.

  11. Report number codes

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, R.N. (ed.)

    1985-05-01

    This publication lists all report number codes processed by the Office of Scientific and Technical Information. The report codes are substantially based on the American National Standards Institute, Standard Technical Report Number (STRN)-Format and Creation Z39.23-1983. The Standard Technical Report Number (STRN) provides one of the primary methods of identifying a specific technical report. The STRN consists of two parts: The report code and the sequential number. The report code identifies the issuing organization, a specific program, or a type of document. The sequential number, which is assigned in sequence by each report issuing entity, is not included in this publication. Part I of this compilation is alphabetized by report codes followed by issuing installations. Part II lists the issuing organization followed by the assigned report code(s). In both Parts I and II, the names of issuing organizations appear for the most part in the form used at the time the reports were issued. However, for some of the more prolific installations which have had name changes, all entries have been merged under the current name.

  12. Report number codes

    International Nuclear Information System (INIS)

    Nelson, R.N.

    1985-05-01

    This publication lists all report number codes processed by the Office of Scientific and Technical Information. The report codes are substantially based on the American National Standards Institute, Standard Technical Report Number (STRN)-Format and Creation Z39.23-1983. The Standard Technical Report Number (STRN) provides one of the primary methods of identifying a specific technical report. The STRN consists of two parts: The report code and the sequential number. The report code identifies the issuing organization, a specific program, or a type of document. The sequential number, which is assigned in sequence by each report issuing entity, is not included in this publication. Part I of this compilation is alphabetized by report codes followed by issuing installations. Part II lists the issuing organization followed by the assigned report code(s). In both Parts I and II, the names of issuing organizations appear for the most part in the form used at the time the reports were issued. However, for some of the more prolific installations which have had name changes, all entries have been merged under the current name

  13. Oil and Gas Field Code Master List 1990

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-04

    This is the ninth annual edition of the Energy Information Administration's (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1990 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. There are 54,963 field records in this year's Oil and Gas Field Code Master List (FCML). This amounts to 467 more than in last year's report. As it is maintained by EIA, the Master List includes: Field records for each state and county in which a field resides; field records for each offshore area block in the Gulf of Mexico in which a field resides;field records for each alias field name; fields crossing state boundaries that may be assigned different names by the respective state naming authorities.

  14. Authorization request for potential non-compliance with the American Standard Safety Code for Elevators Dumbwaiters and Escalators

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, J.E.

    1964-09-28

    A Third Party inspection of the reactor work platforms was conducted by representatives of the Travelers Insurance Company in 1958. An inspection report submitted by these representatives described hazardous conditions noted and presented a series of recommendations to improve the operational safety of the systems. Project CGI-960, ``C`` & ``D`` Work Platform Safety Improvements -- All Reactors, vas initiated to modify the platforms in compliance with the Third Party recommendations. The American Standard Safety Code for Elevators Dumbwaiters and Escalators (A-17.1) is used as a guide by the Third Party in formulating their recommendations. This code is used because there is no other applicable code for this type of equipment. While the work platforms do not and in some cases can not comply with this code because of operational use, every effort is made to comply with the intent of the code.

  15. Forest management practices and the occupational safety and health administration logging standard

    Science.gov (United States)

    John R. Myers; David Elton Fosbroke

    1995-01-01

    The Occupational Safety and Health Administration (OSHA) has established safety and health regulations for the logging industry. These new regulations move beyond the prior OSHA pulpwood harvesting standard by including sawtimber harvesting operations. Because logging is a major tool used by forest managers to meet silvicultural goals, managers must be aware of what...

  16. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-2001 as the Commercial Building Energy Code in Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Winiarski, David W.; Belzer, David B.; Richman, Eric E.

    2004-09-30

    ASHRAE Standard 90.1-2001 Energy Standard for Buildings except Low-Rise Residential Buildings (hereafter referred to as ASHRAE 90.1-2001 or 90.1-2001) was developed in an effort to set minimum requirements for the energy efficient design and construction of new commercial buildings. The State of Tennessee is considering adopting ASHRAE 90.1-2001 as its commercial building energy code. In an effort to evaluate whether or not this is an appropriate code for the state, the potential benefits and costs of adopting this standard are considered in this report. Both qualitative and quantitative benefits and costs are assessed. Energy and economic impacts are estimated using the Building Loads Analysis and System Thermodynamics (BLAST) simulations combined with a Life-Cycle Cost (LCC) approach to assess corresponding economic costs and benefits. Tennessee currently has ASHRAE Standard 90A-1980 as the statewide voluntary/recommended commercial energy standard; however, it is up to the local jurisdiction to adopt this code. Because 90A-1980 is the recommended standard, many of the requirements of ASHRAE 90A-1980 were used as a baseline for simulations.

  17. Simulation of International Standard Problem No. 44 'KAEVER' experiments on aerosol behaviour with the CONTAIN code

    International Nuclear Information System (INIS)

    Kljenak, I.

    2001-01-01

    Experiments on aerosol behavior in a vapor-saturated atmosphere, which were performed in the KAEVER experimental facility and proposed for the OECD International Standard Problem No. 44, were simulated with the CONTAIN thermal-hydraulic computer code. The purpose of the work was to assess the capability of the CONTAIN code to model aerosol condensation and deposition in a containment of a light-water-reactor nuclear power plant at severe accident conditions. Results of dry and wet aerosol concentrations are presented and analyzed.(author)

  18. A Study of Clinical Coding Accuracy in Surgery: Implications for the Use of Administrative Big Data for Outcomes Management.

    Science.gov (United States)

    Nouraei, S A R; Hudovsky, A; Frampton, A E; Mufti, U; White, N B; Wathen, C G; Sandhu, G S; Darzi, A

    2015-06-01

    Clinical coding is the translation of clinical activity into a coded language. Coded data drive hospital reimbursement and are used for audit and research, and benchmarking and outcomes management purposes. We undertook a 2-center audit of coding accuracy across surgery. Clinician-auditor multidisciplinary teams reviewed the coding of 30,127 patients and assessed accuracy at primary and secondary diagnosis and procedure levels, morbidity level, complications assignment, and financial variance. Postaudit data of a randomly selected sample of 400 cases were reaudited by an independent team. At least 1 coding change occurred in 15,402 patients (51%). There were 3911 (13%) and 3620 (12%) changes to primary diagnoses and procedures, respectively. In 5183 (17%) patients, the Health Resource Grouping changed, resulting in income variance of £3,974,544 (+6.2%). The morbidity level changed in 2116 (7%) patients (P data are a key engine for knowledge-driven health care provision. They are used, increasingly at individual surgeon level, to benchmark performance. Surgical clinical coding is prone to subjectivity, variability, and error (SVE). Having a specialty-by-specialty understanding of the nature and clinical significance of informatics variability and adopting strategies to reduce it, are necessary to allow accurate assumptions and informed decisions to be made concerning the scope and clinical applicability of administrative data in surgical outcomes improvement.

  19. International standard problem (ISP) no. 41 follow up exercise: Containment iodine computer code exercise: parametric studies

    Energy Technology Data Exchange (ETDEWEB)

    Ball, J.; Glowa, G.; Wren, J. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Ewig, F. [GRS Koln (Germany); Dickenson, S. [AEAT, (United Kingdom); Billarand, Y.; Cantrel, L. [IPSN (France); Rydl, A. [NRIR (Czech Republic); Royen, J. [OECD/NEA (France)

    2001-11-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I{sup -} concentration. The codes used in this exercise were IODE(IPSN), IODE(NRIR), IMPAIR(GRS), INSPECT(AEAT), IMOD(AECL) and LIRIC(AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained front intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility, (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (author)

  20. International standard problem (ISP) no. 41 follow up exercise: Containment iodine computer code exercise: parametric studies

    International Nuclear Information System (INIS)

    Ball, J.; Glowa, G.; Wren, J.; Ewig, F.; Dickenson, S.; Billarand, Y.; Cantrel, L.; Rydl, A.; Royen, J.

    2001-11-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I - concentration. The codes used in this exercise were IODE(IPSN), IODE(NRIR), IMPAIR(GRS), INSPECT(AEAT), IMOD(AECL) and LIRIC(AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained front intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility, (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (author)

  1. Codes and standards an European point of view

    International Nuclear Information System (INIS)

    Roche, R.L.; Corsi, F.

    1987-01-01

    The first part of this paper is related to the European situation in which Construction Codes for FBR components are developed. Attention is given to the different agreements between European Countries. After a description of the present state of Codes development, indications are given on the future work in this field. Several appendix are devoted to the state of Codes in different European Countries and to the action of European Commission

  2. Reliability improvement: where do we go from here. The role of codes and standards

    International Nuclear Information System (INIS)

    Davidson, R.H.

    1976-01-01

    The role of codes and standards in contributing to the future improvement is discussed. The Nuclear Plant Reliability Data System is examined. It is suggested that two systems of the type are needed. One system should focus on component and system reliability while the other should focus on system availability, capacity factor, and fixed outage rate assessment

  3. Cement: Administrative tender specifications and standards in Spain

    Directory of Open Access Journals (Sweden)

    Soria Santamaría, Francisco

    1991-03-01

    Full Text Available The paper describes, in chronological order, the different competent Authorities in Spain and the documents issued by them regarding Cement Regulations and Standards. The origin of the early cement quality Rules is referred to, the issuing of Regulations by the Public Bodies and finally the adoption of National Standards on the one hand, as well as the first initiatives to establish International Standards, especially motivated by the export boom after the Second World War, on the other. The second part of the paper offers a brief synthesis of the terms and conditions for cement in Administrative Tender Specifications from 1919 to date regarding definitions, classifications and specifications. Finally the present state of the art is outlined in a series of Tables describing the cement standards in force in Spain.

    Se empieza exponiendo, en orden cronológico, los organismos españoles y documentos elaborados por los mismos relativos a Reglamentos y Normas sobre cementos. Se justifica el origen de las primeras reglas para establecer la calidad de los cementos, la aparición de reglamentos por parte de las Administraciones públicas y la elaboración de normas a nivel nacional, en primer término, y los inicios de normas internacionales con motivo del auge de las exportaciones acabada la 2ª Guerra Mundial, en segundo lugar. A continuación se hace un breve resumen de la evolución de los Pliegos de Cemento en España desde 1919 hasta nuestros días, en lo que se refiere a Definiciones, Clasificación, Nomenclatura y Especificaciones. Finalmente, se incluye en forma tabulada la situación actual de las normas sobre cementos en España.

  4. The cost of implementing inpatient bar code medication administration.

    Science.gov (United States)

    Sakowski, Julie Ann; Ketchel, Alan

    2013-02-01

    To calculate the costs associated with implementing and operating an inpatient bar-code medication administration (BCMA) system in the community hospital setting and to estimate the cost per harmful error prevented. This is a retrospective, observational study. Costs were calculated from the hospital perspective and a cost-consequence analysis was performed to estimate the cost per preventable adverse drug event averted. Costs were collected from financial records and key informant interviews at 4 not-for profit community hospitals. Costs included direct expenditures on capital, infrastructure, additional personnel, and the opportunity costs of time for existing personnel working on the project. The number of adverse drug events prevented using BCMA was estimated by multiplying the number of doses administered using BCMA by the rate of harmful errors prevented by interventions in response to system warnings. Our previous work found that BCMA identified and intercepted medication errors in 1.1% of doses administered, 9% of which potentially could have resulted in lasting harm. The cost of implementing and operating BCMA including electronic pharmacy management and drug repackaging over 5 years is $40,000 (range: $35,600 to $54,600) per BCMA-enabled bed and $2000 (range: $1800 to $2600) per harmful error prevented. BCMA can be an effective and potentially cost-saving tool for preventing the harm and costs associated with medication errors.

  5. The AutoProof Verifier: Usability by Non-Experts and on Standard Code

    Directory of Open Access Journals (Sweden)

    Carlo A. Furia

    2015-08-01

    Full Text Available Formal verification tools are often developed by experts for experts; as a result, their usability by programmers with little formal methods experience may be severely limited. In this paper, we discuss this general phenomenon with reference to AutoProof: a tool that can verify the full functional correctness of object-oriented software. In particular, we present our experiences of using AutoProof in two contrasting contexts representative of non-expert usage. First, we discuss its usability by students in a graduate course on software verification, who were tasked with verifying implementations of various sorting algorithms. Second, we evaluate its usability in verifying code developed for programming assignments of an undergraduate course. The first scenario represents usability by serious non-experts; the second represents usability on "standard code", developed without full functional verification in mind. We report our experiences and lessons learnt, from which we derive some general suggestions for furthering the development of verification tools with respect to improving their usability.

  6. PEAR code review

    International Nuclear Information System (INIS)

    De Wit, R.; Jamieson, T.; Lord, M.; Lafortune, J.F.

    1997-07-01

    As a necessary component in the continuous improvement and refinement of methodologies employed in the nuclear industry, regulatory agencies need to periodically evaluate these processes to improve confidence in results and ensure appropriate levels of safety are being achieved. The independent and objective review of industry-standard computer codes forms an essential part of this program. To this end, this work undertakes an in-depth review of the computer code PEAR (Public Exposures from Accidental Releases), developed by Atomic Energy of Canada Limited (AECL) to assess accidental releases from CANDU reactors. PEAR is based largely on the models contained in the Canadian Standards Association (CSA) N288.2-M91. This report presents the results of a detailed technical review of the PEAR code to identify any variations from the CSA standard and other supporting documentation, verify the source code, assess the quality of numerical models and results, and identify general strengths and weaknesses of the code. The version of the code employed in this review is the one which AECL intends to use for CANDU 9 safety analyses. (author)

  7. Validity of congenital malformation diagnostic codes recorded in Québec's administrative databases.

    Science.gov (United States)

    Blais, Lucie; Bérard, Anick; Kettani, Fatima-Zohra; Forget, Amélie

    2013-08-01

    To assess the validity of the diagnostic codes of congenital malformations (CMs) recorded in two of Québec's administrative databases. A cohort of pregnancies and infants born to asthmatic and non-asthmatic women in 1990-2002 was reconstructed using Québec's administrative databases. From this cohort, we selected 269 infants with a CM and 144 without CM born to asthmatic women, together with 284 and 138 infants, respectively, born to non-asthmatic women. The diagnoses of CMs recorded in the databases were compared with the diagnoses written by the physicians in the infants' medical charts. The positive predictive values (PPV) and negative predictive values (NPV) for all, major, and several specific CMs were estimated. The PPVs for all CMs and major CMs were 82.2% (95% confidence interval (CI): 78.5%-85.9%) and 78.1% (74.1%-82.1%), respectively, in the asthmatic group and were 79.2% (75.4%-83.1%) and 69.0% (64.6%-73.4%), respectively, in the non-asthmatic group. PPVs >80% were found for several specific CMs, including cardiac, cleft, and limb CMs in both groups. The NPV for any CM was 88.2% (95% CI: 85.1%-91.3%) in the asthmatic group and 94.2% (92.2%-96.2%) in the non-asthmatic group. Québec's administrative databases are valid tools for epidemiological research of CMs. The results were similar between infants born to women with and without asthma. Copyright © 2013 John Wiley & Sons, Ltd.

  8. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Miscellaneous -- Volume 3, Revision 4

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, L.M.; Jordon, W.C. [Oak Ridge National Lab., TN (United States); Edwards, A.L. [Oak Ridge National Lab., TN (United States)]|[Lawrence Livermore National Lab., CA (United States)] [and others

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice; (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System developments has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3--for the data libraries and subroutine libraries.

  9. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Miscellaneous -- Volume 3, Revision 4

    International Nuclear Information System (INIS)

    Petrie, L.M.; Jordon, W.C.; Edwards, A.L.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice; (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System developments has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3--for the data libraries and subroutine libraries

  10. HCPB TBM thermo mechanical design: Assessment with respect codes and standards and DEMO relevancy

    International Nuclear Information System (INIS)

    Cismondi, F.; Kecskes, S.; Aiello, G.

    2011-01-01

    In the frame of the activities of the European TBM Consortium of Associates the Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) is developed in Karlsruhe Institute of Technology (KIT). After performing detailed thermal and fluid dynamic analyses of the preliminary HCPB TBM design, the thermo mechanical behaviour of the TBM under typical ITER loads has to be assessed. A synthesis of the different design options proposed has been realized building two different assemblies of the HCPB-TBM: these two assemblies and the analyses performed on them are presented in this paper. Finite Element thermo-mechanical analyses of two detailed 1/4 scaled models of the HCPB-TBM assemblies proposed have been performed, with the aim of verifying the accordance of the mechanical behaviour with the criteria of the design codes and standards. The structural design limits specified in the codes and standard are discussed in relation with the EUROFER available data and possible damage modes. Solutions to improve the weak structural points of the present design are identified and the DEMO relevancy of the present thermal and structural design parameters is discussed.

  11. The network code

    International Nuclear Information System (INIS)

    1997-01-01

    The Network Code defines the rights and responsibilities of all users of the natural gas transportation system in the liberalised gas industry in the United Kingdom. This report describes the operation of the Code, what it means, how it works and its implications for the various participants in the industry. The topics covered are: development of the competitive gas market in the UK; key points in the Code; gas transportation charging; impact of the Code on producers upstream; impact on shippers; gas storage; supply point administration; impact of the Code on end users; the future. (20 tables; 33 figures) (UK)

  12. The Coding Causes of Death in HIV (CoDe) Project: initial results and evaluation of methodology

    DEFF Research Database (Denmark)

    Kowalska, Justyna D; Friis-Møller, Nina; Kirk, Ole

    2011-01-01

    The Coding Causes of Death in HIV (CoDe) Project aims to deliver a standardized method for coding the underlying cause of death in HIV-positive persons, suitable for clinical trials and epidemiologic studies.......The Coding Causes of Death in HIV (CoDe) Project aims to deliver a standardized method for coding the underlying cause of death in HIV-positive persons, suitable for clinical trials and epidemiologic studies....

  13. ENDF-UTILITY-CODES, codes to check and standardize data in the Evaluated Nuclear Data File (ENDF)

    International Nuclear Information System (INIS)

    Dunford, Charles L.

    2007-01-01

    1 - Description of program or function: The ENDF Utility Codes include 9 codes to check and standardize data in the Evaluated Nuclear Data File (ENDF). Four programs of this release, GETMAT, LISTEF, PLOTEF and SETMDC are no more maintained since release 6.13. The suite of ENDF utility codes includes: - CHECKR (version 7.01) is a program for checking that an evaluated data file conforms to the ENDF format. - FIZCON (version 7.02) is a program for checking that an evaluated data file has valid data and conforms to recommended procedures. - GETMAT (version 6.13) is designed to retrieve one or more materials from an ENDF formatted data file. The output will contain only the selected materials. - INTER (version 7.01) calculates thermal cross sections, g-factors, resonance integrals, fission spectrum averaged cross sections and 14.0 MeV (or other energy) cross sections for major reactions in an ENDF-6 or ENDF-5 format data file. - LISTEF (version 6.13) is designed to produce summary and annotated listings of a data file in either ENDF-6 or ENDF-5 format. - PLOTEF (version 6.13) is designed to produce graphical displays of a data file in either ENDF-5 or ENDF-6 format. The form of graphical output depends on the graphical devices available at the installation where this code will be used. - PSYCHE (version 7.02) is a program for checking the physics content of an evaluated data file. It can recognise the difference between ENDF-5 or ENDF-6 formats and performs its tests accordingly. - SETMDC (version 6.13) is a utility program that converts the source decks of programs to different computers (DOS, UNIX, LINUX, VMS, Windows). - STANEF (version 7.01) performs bookkeeping operations on a data file containing one or more material evaluations in ENDF format. The version 7.02 of the ENDF Utility Codes corrects all bugs reported to NNDC as of April 1, 2005 and supersedes all previous releases. Three codes CHECKR, STANEF, and INTER were actually ported from the 7.01 release

  14. Series of standards for use by an oil and gas production administration for progress-of work reports and inventory control

    Energy Technology Data Exchange (ETDEWEB)

    Kucherniuk, V A; Eliseev, V G; Iskandarov, R G

    1981-01-01

    Based on a study of the characteristics of product flows from oil wells, the test and monitoring equipment used to monitor the quantity of oil, and the standard documentation, it is demonstrated that in order to increase the measurement accuracy of the product produced by the oil and gas production administration, it is necessary to develop a system of enterprise standards to account for it. A list is given of standards of use by oil and gas production administration to account for its product. The use of the standards with existing metering equipment makes it possible to decrease the variation between operational and inventory records for the quantity of oil at the ''Rechitsaneft'' oil and gas production administration up to 5% and consequently to increase the control efficiency over the operation of the fields.

  15. Simulation of international standard problem no. 44 open tests using Melcor computer code

    International Nuclear Information System (INIS)

    Song, Y.M.; Cho, S.W.

    2001-01-01

    MELCOR 1.8.4 code has been employed to simulate the KAEVER test series of K123/K148/K186/K188 that were proposed as open experiments of International Standard Problem No.44 by OECD-CSNI. The main purpose of this study is to evaluate the accuracy of the MELCOR aerosol model which calculates the aerosol distribution and settlement in a containment. For this, thermal hydraulic conditions are simulated first for the whole test period and then the behavior of hygroscopic CsOH/CsI and unsoluble Ag aerosols, which are predominant activity carriers in a release into the containment, is compared between the experimental results and the code predictions. The calculation results of vessel atmospheric concentration show a good simulation for dry aerosol but show large difference for wet aerosol due to a data mismatch in vessel humidity and the hygroscopicity. (authors)

  16. Entanglement-assisted quantum MDS codes from negacyclic codes

    Science.gov (United States)

    Lu, Liangdong; Li, Ruihu; Guo, Luobin; Ma, Yuena; Liu, Yang

    2018-03-01

    The entanglement-assisted formalism generalizes the standard stabilizer formalism, which can transform arbitrary classical linear codes into entanglement-assisted quantum error-correcting codes (EAQECCs) by using pre-shared entanglement between the sender and the receiver. In this work, we construct six classes of q-ary entanglement-assisted quantum MDS (EAQMDS) codes based on classical negacyclic MDS codes by exploiting two or more pre-shared maximally entangled states. We show that two of these six classes q-ary EAQMDS have minimum distance more larger than q+1. Most of these q-ary EAQMDS codes are new in the sense that their parameters are not covered by the codes available in the literature.

  17. ZAKI: a windows-based ko standardization code for in-core INAA

    International Nuclear Information System (INIS)

    Ojo, J.O.; Filby, R.H.

    2002-01-01

    A new computer code ZAKI, for k o -based INAA standardization, written in Visual Basic for the WINDOWS environment is described. The parameter α measuring the deviation of the epithermal neutron spectrum shape from the ideal 1/E shape, and the thermal-to-epithermal flux ratio f, are monitored at each irradiation position for each irradiation using the ''triple bare monitor with k o '' technique. Stability of the irradiation position with respect to α and f is therefore assumed only for the duration of the irradiation. This now makes it possible to use k o standardization even for in-core reactor irradiation channels without an a priori knowledge of α and f values as required by existing commercial software. ZAKI is considerably versatile and contains features which allow for use of several detectors at different counting geometries, direct inputting of peak search output from GeniePc, and automatic nuclide identification of all gamma lines using an in-built library. Sample results for two certified reference materials are presented

  18. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 5

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Fire Protection functional area for the Hanford Site Tank Farm facilities and support structures is based on the application of relevant DOE orders, regulations, and industry codes and standards. The fire protection program defined in this document may be divided into three areas: (1) organizational, (2) administrative programmatic features, and (3) technical features. The information presented in each section is in the form of program elements and orders, regulations, industry codes, and standards that serve as the attributes of a fire protection program for the Tank Farm facilities. Upon completion this document will be utilized as the basis to evaluate compliance of the fire protection program being implemented for the Tank Farm facilities with the requirements of DOE orders and industry codes and standards.

  19. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 5

    International Nuclear Information System (INIS)

    1994-04-01

    The Fire Protection functional area for the Hanford Site Tank Farm facilities and support structures is based on the application of relevant DOE orders, regulations, and industry codes and standards. The fire protection program defined in this document may be divided into three areas: (1) organizational, (2) administrative programmatic features, and (3) technical features. The information presented in each section is in the form of program elements and orders, regulations, industry codes, and standards that serve as the attributes of a fire protection program for the Tank Farm facilities. Upon completion this document will be utilized as the basis to evaluate compliance of the fire protection program being implemented for the Tank Farm facilities with the requirements of DOE orders and industry codes and standards

  20. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Control modules -- Volume 1, Revision 4

    Energy Technology Data Exchange (ETDEWEB)

    Landers, N.F.; Petrie, L.M.; Knight, J.R. [Oak Ridge National Lab., TN (United States)] [and others

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3 for the documentation of the data libraries and subroutine libraries.

  1. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Control modules -- Volume 1, Revision 4

    International Nuclear Information System (INIS)

    Landers, N.F.; Petrie, L.M.; Knight, J.R.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3 for the documentation of the data libraries and subroutine libraries

  2. Applications guide to the RSIC-distributed version of the MCNP code (coupled Monte Carlo neutron-photon Code)

    International Nuclear Information System (INIS)

    Cramer, S.N.

    1985-09-01

    An overview of the RSIC-distributed version of the MCNP code (a soupled Monte Carlo neutron-photon code) is presented. All general features of the code, from machine hardware requirements to theoretical details, are discussed. The current nuclide cross-section and other libraries available in the standard code package are specified, and a realistic example of the flexible geometry input is given. Standard and nonstandard source, estimator, and variance-reduction procedures are outlined. Examples of correct usage and possible misuse of certain code features are presented graphically and in standard output listings. Finally, itemized summaries of sample problems, various MCNP code documentation, and future work are given

  3. ASTM and ASME-BPE Standards--Complying with the Needs of the Pharmaceutical Industry.

    Science.gov (United States)

    Huitt, William M

    2011-01-01

    Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. Through harmonization efforts this relatively new standard has brought together, scrutinized, and refined industry accepted methodologies together with FDA compliance requirements, and has established an American National Standard that provides a comprehensive set of standards that are integral to the pharmaceutical industry. This article describes various American National Standards, including those developed and published by the American Society for Testing and Materials (ASTM), and how they apply to the pharmaceutical industry. It goes on to discuss the harmonization effort that takes place between the various standards developers in an attempt to prevent conflicts and omissions between the many standards. Also included are examples of tables and figures taken from the ASME-BPE Standard. These examples provide the reader with insight to the relevant content of the ASME-BPE Standard. Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and

  4. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    International Nuclear Information System (INIS)

    2002-01-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in 60 Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and satisfies

  5. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in {sup 60}Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and

  6. Protection of proprietary rights of DIN standards in connection with statutory and administrative provisions

    International Nuclear Information System (INIS)

    Katzenberger, P.

    1985-01-01

    On the basis of contracts entered with the German Institute of Standardization (DIN), the state bodies and authorities tend to refer to Din standards in many ways when issuing statutory or administrative provisions. Some Din standards are also printed in official publications- with or without Din's prior consent. Such common practice leads to the question whether the Din standards which on pinciple meet the general requirements made on the protection of proprietary rights are losing this protection by the fact that official publications are exempt from the protection of proprietary rights (Art.5 UrhG). The author points out that the thorough analysis of the legal position in terms of interests, proprietary rights and constitution indicated that this is not, in principle, the case. (orig.) [de

  7. Association between workarounds and medication administration errors in bar-code-assisted medication administration in hospitals

    NARCIS (Netherlands)

    van der Veen, Willem; van den Bemt, Patricia M L A; Wouters, Hans; Bates, David W; Twisk, Jos W R; de Gier, Johan J; Taxis, Katja

    Objective: To study the association of workarounds with medication administration errors using barcode-assisted medication administration (BCMA), and to determine the frequency and types of workarounds and medication administration errors. Materials and Methods: A prospective observational study in

  8. 78 FR 29245 - U.S. General Services Administration Federal Property Management Regulations; Administrative Wage...

    Science.gov (United States)

    2013-05-20

    ... Federal Property Management Regulations; Administrative Wage Garnishment AGENCY: Office of the Chief... the U.S. General Services Administration Property Management Regulation (GSPMR) to remove information... Administrative Wage Garnishment Code of Federal Regulations (CFR) Parts affected are as follows: 41 CFR part 105...

  9. 45 CFR 162.1011 - Valid code sets.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Valid code sets. 162.1011 Section 162.1011 Public... ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1011 Valid code sets. Each code set is valid within the dates specified by the organization responsible for maintaining that code set. ...

  10. Telemetry Standards, RCC Standard 106-17. Chapter 8. Digital Data Bus Acquisition Formatting Standard

    Science.gov (United States)

    2017-07-01

    incorrect word count/message and illegal mode codes are not considered bus errors. 8.6.2 Source Signal The source of data is a signal conforming to...Telemetry Standards, RCC Standard 106-17 Chapter 8, July 2017 CHAPTER 8 Digital Data Bus Acquisition Formatting Standard Acronyms...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation

  11. The International Standards Organisation offshore structures standard

    International Nuclear Information System (INIS)

    Snell, R.O.

    1994-01-01

    The International Standards Organisation has initiated a program to develop a suite of ISO Codes and Standards for the Oil Industry. The Offshore Structures Standard is one of seven topics being addressed. The scope of the standard will encompass fixed steel and concrete structures, floating structures, Arctic structures and the site specific assessment of mobile drilling and accommodation units. The standard will use as base documents the existing recommended practices and standards most frequently used for each type of structure, and will develop them to incorporate best published and recognized practice and knowledge where it provides a significant improvement on the base document. Work on the Code has commenced under the direction of an internationally constituted sub-committee comprising representatives from most of the countries with a substantial offshore oil and gas industry. This paper outlines the background to the code and the format, content and work program

  12. 20 CFR Appendix A to Part 718 - Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays)

    Science.gov (United States)

    2010-04-01

    ... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits EMPLOYMENT STANDARDS... 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The following... procedures are used in administering and interpreting X-rays and that the best available medical evidence...

  13. Genetic hotels for the standard genetic code: evolutionary analysis based upon novel three-dimensional algebraic models.

    Science.gov (United States)

    José, Marco V; Morgado, Eberto R; Govezensky, Tzipe

    2011-07-01

    Herein, we rigorously develop novel 3-dimensional algebraic models called Genetic Hotels of the Standard Genetic Code (SGC). We start by considering the primeval RNA genetic code which consists of the 16 codons of type RNY (purine-any base-pyrimidine). Using simple algebraic operations, we show how the RNA code could have evolved toward the current SGC via two different intermediate evolutionary stages called Extended RNA code type I and II. By rotations or translations of the subset RNY, we arrive at the SGC via the former (type I) or via the latter (type II), respectively. Biologically, the Extended RNA code type I, consists of all codons of the type RNY plus codons obtained by considering the RNA code but in the second (NYR type) and third (YRN type) reading frames. The Extended RNA code type II, comprises all codons of the type RNY plus codons that arise from transversions of the RNA code in the first (YNY type) and third (RNR) nucleotide bases. Since the dimensions of remarkable subsets of the Genetic Hotels are not necessarily integer numbers, we also introduce the concept of algebraic fractal dimension. A general decoding function which maps each codon to its corresponding amino acid or the stop signals is also derived. The Phenotypic Hotel of amino acids is also illustrated. The proposed evolutionary paths are discussed in terms of the existing theories of the evolution of the SGC. The adoption of 3-dimensional models of the Genetic and Phenotypic Hotels will facilitate the understanding of the biological properties of the SGC.

  14. 75 FR 20833 - Building Energy Codes

    Science.gov (United States)

    2010-04-21

    ...-0012] Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... the current model building energy codes or their equivalent. DOE is interested in better understanding... codes, Standard 90.1-2007, Energy Standard for Buildings Except Low-Rise Residential Buildings (or...

  15. Fire-safety engineering and performance-based codes

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    project administrators, etc. The book deals with the following topics: • Historical presentation on the subject of fire • Legislation and building project administration • European fire standardization • Passive and active fire protection • Performance-based Codes • Fire-safety Engineering • Fundamental......Fire-safety Engineering is written as a textbook for Engineering students at universities and other institutions of higher education that teach in the area of fire. The book can also be used as a work of reference for consulting engineers, Building product manufacturers, contractors, building...... thermodynamics • Heat exchange during the fire process • Skin burns • Burning rate, energy release rate and design fires • Proposal to Risk-based design fires • Proposal to a Fire scale • Material ignition and flame spread • Fire dynamics in buildings • Combustion products and toxic gases • Smoke inhalation...

  16. Are industry codes and standards a valid cost containment approach

    International Nuclear Information System (INIS)

    Rowley, C.W.; Simpson, G.T.; Young, R.K.

    1990-01-01

    The nuclear industry has historically concentrated on safety design features for many years, but recently has been shifting to the reliability of the operating systems and components. The Navy has already gone through this transition and has found that Reliability Centered Maintenance (RCM) is an invaluable tool to improve the reliability of components, systems, ships, and classes of ships. There is a close correlation of Navy ships and equipment to commercial nuclear power plants and equipment. The Navy has a central engineering and configuration management organization (Naval Sea Systems Command) for over 500 ships, where as the over 100 commercial nuclear power plants and 52 nuclear utilities represent a fragmented owner/management structure. This paper suggests that the results of the application of RCM in the Navy can be duplicated to a large degree in the commercial nuclear power industry by the development and utilization of nuclear codes and standards

  17. 22 CFR 139.4 - Responsibilities of the Program Administrator.

    Science.gov (United States)

    2010-04-01

    ... of living, support infrastructure, and other relevant factors. The Program Administrator, from time... program regulations, including rules of the Program Administrator and the code of code of conduct; or the...

  18. A Code of Ethics and Standards for Outer-Space Commerce

    Science.gov (United States)

    Livingston, David M.

    2002-01-01

    Now is the time to put forth an effective code of ethics for businesses in outer space. A successful code would be voluntary and would actually promote the growth of individual companies, not hinder their efforts to provide products and services. A properly designed code of ethics would ensure the development of space commerce unfettered by government-created barriers. Indeed, if the commercial space industry does not develop its own professional code of ethics, government- imposed regulations would probably be instituted. Should this occur, there is a risk that the development of off-Earth commerce would become more restricted. The code presented in this paper seeks to avoid the imposition of new barriers to space commerce as well as make new commercial space ventures easier to develop. The proposed code consists of a preamble, which underscores basic values, followed by a number of specific principles. For the most part, these principles set forth broad commitments to fairness and integrity with respect to employees, consumers, business transactions, political contributions, natural resources, off-Earth development, designated environmental protection zones, as well as relevant national and international laws. As acceptance of this code of ethics grows within the industry, general modifications will be necessary to accommodate the different types of businesses entering space commerce. This uniform applicability will help to assure that the code will not be perceived as foreign in nature, potentially restrictive, or threatening. Companies adopting this code of ethics will find less resistance to their space development plans, not only in the United States but also from nonspacefaring nations. Commercial space companies accepting and refining this code would demonstrate industry leadership and an understanding that will serve future generations living, working, and playing in space. Implementation of the code would also provide an off-Earth precedent for a modified

  19. SITA version 0. A simulation and code testing assistant for TOUGH2 and MARNIE

    Energy Technology Data Exchange (ETDEWEB)

    Seher, Holger; Navarro, Martin

    2016-06-15

    High quality standards have to be met by those numerical codes that are applied in long-term safety assessments for deep geological repositories for radioactive waste. The software environment SITA (''a simulation and code testing assistant for TOUGH2 and MARNIE'') has been developed by GRS in order to perform automated regression testing for the flow and transport simulators TOUGH2 and MARNIE. GRS uses the codes TOUGH2 and MARNIE in order to assess the performance of deep geological repositories for radioactive waste. With SITA, simulation results of TOUGH2 and MARNIE can be compared to analytical solutions and simulations results of other code versions. SITA uses data interfaces to operate with codes whose input and output depends on the code version. The present report is part of a wider GRS programme to assure and improve the quality of TOUGH2 and MARNIE. It addresses users as well as administrators of SITA.

  20. Remote-Handled Transuranic Content Codes

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2006-12-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  1. 24 CFR 200.925c - Model codes.

    Science.gov (United States)

    2010-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  2. Second ATLAS Domestic Standard Problem (DSP-02) For A Code Assessment

    International Nuclear Information System (INIS)

    Kim, Yeonsik; Choi, Kiyong; Cho, Seok; Park, Hyunsik; Kang, Kyungho; Song, Chulhwa; Baek, Wonpil

    2013-01-01

    KAERI (Korea Atomic Energy Research Institute) has been operating an integral effect test facility, the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS), for transient and accident simulations of advanced pressurized water reactors (PWRs). Using ATLAS, a high-quality integral effect test database has been established for major design basis accidents of the APR1400 plant. A Domestic Standard Problem (DSP) exercise using the ATLAS database was promoted to transfer the database to domestic nuclear industries and contribute to improving a safety analysis methodology for PWRs. This 2 nd ATLAS DSP (DSP-02) exercise aims at an effective utilization of an integral effect database obtained from ATLAS, the establishment of a cooperation framework among the domestic nuclear industry, a better understanding of the thermal hydraulic phenomena, and an investigation into the possible limitation of the existing best-estimate safety analysis codes. A small break loss of coolant accident with a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. This DSP exercise was performed in an open calculation environment where the integral effect test data was open to participants prior to the code calculations. This paper includes major information of the DSP-02 exercise as well as comparison results between the calculations and the experimental data

  3. SECOND ATLAS DOMESTIC STANDARD PROBLEM (DSP-02 FOR A CODE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    YEON-SIK KIM

    2013-12-01

    Full Text Available KAERI (Korea Atomic Energy Research Institute has been operating an integral effect test facility, the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS, for transient and accident simulations of advanced pressurized water reactors (PWRs. Using ATLAS, a high-quality integral effect test database has been established for major design basis accidents of the APR1400 plant. A Domestic Standard Problem (DSP exercise using the ATLAS database was promoted to transfer the database to domestic nuclear industries and contribute to improving a safety analysis methodology for PWRs. This 2nd ATLAS DSP (DSP-02 exercise aims at an effective utilization of an integral effect database obtained from ATLAS, the establishment of a cooperation framework among the domestic nuclear industry, a better understanding of the thermal hydraulic phenomena, and an investigation into the possible limitation of the existing best-estimate safety analysis codes. A small break loss of coolant accident with a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. This DSP exercise was performed in an open calculation environment where the integral effect test data was open to participants prior to the code calculations. This paper includes major information of the DSP-02 exercise as well as comparison results between the calculations and the experimental data.

  4. Comparison of ICD code-based diagnosis of obesity with measured obesity in children and the implications for health care cost estimates.

    Science.gov (United States)

    Kuhle, Stefan; Kirk, Sara F L; Ohinmaa, Arto; Veugelers, Paul J

    2011-12-21

    Administrative health databases are a valuable research tool to assess health care utilization at the population level. However, their use in obesity research limited due to the lack of data on body weight. A potential workaround is to use the ICD code of obesity to identify obese individuals. The objective of the current study was to investigate the sensitivity and specificity of an ICD code-based diagnosis of obesity from administrative health data relative to the gold standard measured BMI. Linkage of a population-based survey with anthropometric measures in elementary school children in 2003 with longitudinal administrative health data (physician visits and hospital discharges 1992-2006) from the Canadian province of Nova Scotia. Measured obesity was defined based on the CDC cut-offs applied to the measured BMI. An ICD code-based diagnosis obesity was defined as one or more ICD-9 (278) or ICD-10 code (E66-E68) of obesity from a physician visit or a hospital stay. Sensitivity and specificity were calculated and health care cost estimates based on measured obesity and ICD-based obesity were compared. The sensitivity of an ICD code-based obesity diagnosis was 7.4% using ICD codes between 2002 and 2004. Those correctly identified had a higher BMI and had higher health care utilization and costs. An ICD diagnosis of obesity in Canadian administrative health data grossly underestimates the true prevalence of childhood obesity and overestimates the health care cost differential between obese and non-obese children.

  5. Validation of a case definition to define chronic dialysis using outpatient administrative data.

    Science.gov (United States)

    Clement, Fiona M; James, Matthew T; Chin, Rick; Klarenbach, Scott W; Manns, Braden J; Quinn, Robert R; Ravani, Pietro; Tonelli, Marcello; Hemmelgarn, Brenda R

    2011-03-01

    Administrative health care databases offer an efficient and accessible, though as-yet unvalidated, approach to studying outcomes of patients with chronic kidney disease and end-stage renal disease (ESRD). The objective of this study is to determine the validity of outpatient physician billing derived algorithms for defining chronic dialysis compared to a reference standard ESRD registry. A cohort of incident dialysis patients (Jan. 1-Dec. 31, 2008) and prevalent chronic dialysis patients (Jan 1, 2008) was selected from a geographically inclusive ESRD registry and administrative database. Four administrative data definitions were considered: at least 1 outpatient claim, at least 2 outpatient claims, at least 2 outpatient claims at least 90 days apart, and continuous outpatient claims at least 90 days apart with no gap in claims greater than 21 days. Measures of agreement of the four administrative data definitions were compared to a reference standard (ESRD registry). Basic patient characteristics are compared between all 5 patient groups. 1,118,097 individuals formed the overall population and 2,227 chronic dialysis patients were included in the ESRD registry. The three definitions requiring at least 2 outpatient claims resulted in kappa statistics between 0.60-0.80 indicating "substantial" agreement. "At least 1 outpatient claim" resulted in "excellent" agreement with a kappa statistic of 0.81. Of the four definitions, the simplest (at least 1 outpatient claim) performed comparatively to other definitions. The limitations of this work are the billing codes used are developed in Canada, however, other countries use similar billing practices and thus the codes could easily be mapped to other systems. Our reference standard ESRD registry may not capture all dialysis patients resulting in some misclassification. The registry is linked to on-going care so this is likely to be minimal. The definition utilized will vary with the research objective.

  6. Validation of a case definition to define chronic dialysis using outpatient administrative data

    Directory of Open Access Journals (Sweden)

    Klarenbach Scott W

    2011-03-01

    Full Text Available Abstract Background Administrative health care databases offer an efficient and accessible, though as-yet unvalidated, approach to studying outcomes of patients with chronic kidney disease and end-stage renal disease (ESRD. The objective of this study is to determine the validity of outpatient physician billing derived algorithms for defining chronic dialysis compared to a reference standard ESRD registry. Methods A cohort of incident dialysis patients (Jan. 1 - Dec. 31, 2008 and prevalent chronic dialysis patients (Jan 1, 2008 was selected from a geographically inclusive ESRD registry and administrative database. Four administrative data definitions were considered: at least 1 outpatient claim, at least 2 outpatient claims, at least 2 outpatient claims at least 90 days apart, and continuous outpatient claims at least 90 days apart with no gap in claims greater than 21 days. Measures of agreement of the four administrative data definitions were compared to a reference standard (ESRD registry. Basic patient characteristics are compared between all 5 patient groups. Results 1,118,097 individuals formed the overall population and 2,227 chronic dialysis patients were included in the ESRD registry. The three definitions requiring at least 2 outpatient claims resulted in kappa statistics between 0.60-0.80 indicating "substantial" agreement. "At least 1 outpatient claim" resulted in "excellent" agreement with a kappa statistic of 0.81. Conclusions Of the four definitions, the simplest (at least 1 outpatient claim performed comparatively to other definitions. The limitations of this work are the billing codes used are developed in Canada, however, other countries use similar billing practices and thus the codes could easily be mapped to other systems. Our reference standard ESRD registry may not capture all dialysis patients resulting in some misclassification. The registry is linked to on-going care so this is likely to be minimal. The definition

  7. Turbo coding, turbo equalisation and space-time coding for transmission over fading channels

    CERN Document Server

    Hanzo, L; Yeap, B

    2002-01-01

    Against the backdrop of the emerging 3G wireless personal communications standards and broadband access network standard proposals, this volume covers a range of coding and transmission aspects for transmission over fading wireless channels. It presents the most important classic channel coding issues and also the exciting advances of the last decade, such as turbo coding, turbo equalisation and space-time coding. It endeavours to be the first book with explicit emphasis on channel coding for transmission over wireless channels. Divided into 4 parts: Part 1 - explains the necessary background for novices. It aims to be both an easy reading text book and a deep research monograph. Part 2 - provides detailed coverage of turbo conventional and turbo block coding considering the known decoding algorithms and their performance over Gaussian as well as narrowband and wideband fading channels. Part 3 - comprehensively discusses both space-time block and space-time trellis coding for the first time in literature. Par...

  8. Non-Power Reactor Operator Licensing Examiner Standards

    International Nuclear Information System (INIS)

    1994-06-01

    The Non-Power Reactor Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR Part 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, this standard will be revised periodically to accommodate comments and reflect new information or experience

  9. Validation of key behaviourally based mental health diagnoses in administrative data: suicide attempt, alcohol abuse, illicit drug abuse and tobacco use

    Directory of Open Access Journals (Sweden)

    Kim Hyungjin

    2012-01-01

    Full Text Available Abstract Background Observational research frequently uses administrative codes for mental health or substance use diagnoses and for important behaviours such as suicide attempts. We sought to validate codes (International Classification of Diseases, 9th edition, clinical modification diagnostic and E-codes entered in Veterans Health Administration administrative data for patients with depression versus a gold standard of electronic medical record text ("chart notation". Methods Three random samples of patients were selected, each stratified by geographic region, gender, and year of cohort entry, from a VHA depression treatment cohort from April 1, 1999 to September 30, 2004. The first sample was selected from patients who died by suicide, the second from patients who remained alive on the date of death of suicide cases, and the third from patients with a new start of a commonly used antidepressant medication. Four variables were assessed using administrative codes in the year prior to the index date: suicide attempt, alcohol abuse/dependence, drug abuse/dependence and tobacco use. Results Specificity was high (≥ 90% for all four administrative codes, regardless of the sample. Sensitivity was ≤75% and was particularly low for suicide attempt (≤ 17%. Positive predictive values for alcohol dependence/abuse and tobacco use were high, but barely better than flipping a coin for illicit drug abuse/dependence. Sensitivity differed across the three samples, but was highest in the suicide death sample. Conclusions Administrative data-based diagnoses among VHA records have high specificity, but low sensitivity. The accuracy level varies by different diagnosis and by different patient subgroup.

  10. Validation of key behaviourally based mental health diagnoses in administrative data: suicide attempt, alcohol abuse, illicit drug abuse and tobacco use.

    Science.gov (United States)

    Kim, Hyungjin Myra; Smith, Eric G; Stano, Claire M; Ganoczy, Dara; Zivin, Kara; Walters, Heather; Valenstein, Marcia

    2012-01-23

    Observational research frequently uses administrative codes for mental health or substance use diagnoses and for important behaviours such as suicide attempts. We sought to validate codes (International Classification of Diseases, 9th edition, clinical modification diagnostic and E-codes) entered in Veterans Health Administration administrative data for patients with depression versus a gold standard of electronic medical record text ("chart notation"). Three random samples of patients were selected, each stratified by geographic region, gender, and year of cohort entry, from a VHA depression treatment cohort from April 1, 1999 to September 30, 2004. The first sample was selected from patients who died by suicide, the second from patients who remained alive on the date of death of suicide cases, and the third from patients with a new start of a commonly used antidepressant medication. Four variables were assessed using administrative codes in the year prior to the index date: suicide attempt, alcohol abuse/dependence, drug abuse/dependence and tobacco use. Specificity was high (≥ 90%) for all four administrative codes, regardless of the sample. Sensitivity was ≤75% and was particularly low for suicide attempt (≤ 17%). Positive predictive values for alcohol dependence/abuse and tobacco use were high, but barely better than flipping a coin for illicit drug abuse/dependence. Sensitivity differed across the three samples, but was highest in the suicide death sample. Administrative data-based diagnoses among VHA records have high specificity, but low sensitivity. The accuracy level varies by different diagnosis and by different patient subgroup.

  11. Adaptive Coding and Modulation Experiment With NASA's Space Communication and Navigation Testbed

    Science.gov (United States)

    Downey, Joseph; Mortensen, Dale; Evans, Michael; Briones, Janette; Tollis, Nicholas

    2016-01-01

    National Aeronautics and Space Administration (NASA)'s Space Communication and Navigation Testbed is an advanced integrated communication payload on the International Space Station. This paper presents results from an adaptive coding and modulation (ACM) experiment over S-band using a direct-to-earth link between the SCaN Testbed and the Glenn Research Center. The testing leverages the established Digital Video Broadcasting Second Generation (DVB-S2) standard to provide various modulation and coding options, and uses the Space Data Link Protocol (Consultative Committee for Space Data Systems (CCSDS) standard) for the uplink and downlink data framing. The experiment was conducted in a challenging environment due to the multipath and shadowing caused by the International Space Station structure. Several approaches for improving the ACM system are presented, including predictive and learning techniques to accommodate signal fades. Performance of the system is evaluated as a function of end-to-end system latency (round-trip delay), and compared to the capacity of the link. Finally, improvements over standard NASA waveforms are presented.

  12. Battelle integrity of nuclear piping program. Summary of results and implications for codes/standards

    International Nuclear Information System (INIS)

    Miura, Naoki

    2005-01-01

    The BINP(Battelle Integrity of Nuclear Piping) program was proposed by Battelle to elaborate pipe fracture evaluation methods and to improve LBB and in-service flaw evaluation criteria. The program has been conducted from October 1998 to September 2003. In Japan, CRIEPI participated in the program on behalf of electric utilities and fabricators to catch up the technical backgrounds for possible future revision of LBB and in-service flaw evaluation standards and to investigate the issues needed to be reflected to current domestic standards. A series of the results obtained from the program has been well utilized for the new LBB Regulatory Guide Program by USNRC and for proposal of revised in-service flaw evaluation criteria to the ASME Code Committee. The results were assessed whether they had implications for the existing or future domestic standards. As a result, the impact of many of these issues, which were concerned to be adversely affected to LBB approval or allowable flaw sizes in flaw evaluation criteria, was found to be relatively minor under actual plant conditions. At the same time, some issues that needed to be resolved to address advanced and rational standards in the future were specified. (author)

  13. Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Halverson, Mark A.; Myer, Michael; Cho, Hee Jin; Loper, Susan A.; Richman, Eric E.; Elliott, Douglas B.; Mendon, Vrushali V.; Rosenberg, Michael I.

    2013-06-18

    Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components, initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.

  14. Representation mutations from standard genetic codes

    Science.gov (United States)

    Aisah, I.; Suyudi, M.; Carnia, E.; Suhendi; Supriatna, A. K.

    2018-03-01

    Graph is widely used in everyday life especially to describe model problem and describe it concretely and clearly. In addition graph is also used to facilitate solve various kinds of problems that are difficult to be solved by calculation. In Biology, graph can be used to describe the process of protein synthesis in DNA. Protein has an important role for DNA (deoxyribonucleic acid) or RNA (ribonucleic acid). Proteins are composed of amino acids. In this study, amino acids are related to genetics, especially the genetic code. The genetic code is also known as the triplet or codon code which is a three-letter arrangement of DNA nitrogen base. The bases are adenine (A), thymine (T), guanine (G) and cytosine (C). While on RNA thymine (T) is replaced with Urasil (U). The set of all Nitrogen bases in RNA is denoted by N = {C U, A, G}. This codon works at the time of protein synthesis inside the cell. This codon also encodes the stop signal as a sign of the stop of protein synthesis process. This paper will examine the process of protein synthesis through mathematical studies and present it in three-dimensional space or graph. The study begins by analysing the set of all codons denoted by NNN such that to obtain geometric representations. At this stage there is a matching between the sets of all nitrogen bases N with Z 2 × Z 2; C=(\\overline{0},\\overline{0}),{{U}}=(\\overline{0},\\overline{1}),{{A}}=(\\overline{1},\\overline{0}),{{G}}=(\\overline{1},\\overline{1}). By matching the algebraic structure will be obtained such as group, group Klein-4,Quotien group etc. With the help of Geogebra software, the set of all codons denoted by NNN can be presented in a three-dimensional space as a multicube NNN and also can be represented as a graph, so that can easily see relationship between the codon.

  15. Views of Evidence-Based Practice: Social Workers' Code of Ethics and Accreditation Standards as Guides for Choice

    Science.gov (United States)

    Gambrill, Eileen

    2007-01-01

    Different views of evidence-based practice (EBP) include defining it as the use of empirically-validated treatments and practice guidelines (i.e., the EBPs approach) in contrast to the broad philosophy and related evolving process described by the originators. Social workers can draw on their code of ethics and accreditation standards both to…

  16. Inventory of Safety-related Codes and Standards for Energy Storage Systems with some Experiences related to Approval and Acceptance

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.

    2014-09-11

    The purpose of this document is to identify laws, rules, model codes, codes, standards, regulations, specifications (CSR) related to safety that could apply to stationary energy storage systems (ESS) and experiences to date securing approval of ESS in relation to CSR. This information is intended to assist in securing approval of ESS under current CSR and to identification of new CRS or revisions to existing CRS and necessary supporting research and documentation that can foster the deployment of safe ESS.

  17. Cost and code study of underground building: a report to the Minnesota Energy Agency

    Energy Technology Data Exchange (ETDEWEB)

    Sterling, R L

    1979-11-01

    The rapidly intensifying interest in the possible energy savings and environmental and land-use benefits associated with underground buildings has led increasing numbers of people to question restrictions that existing building codes place on underground construction and to make cost comparisons between underground structures and more-conventional buildings. Information in this report on earth-sheltered houses covers public policy issues (building code restrictions, taxation, insurance) and residential construction costs (cost breakdowns, general factors affecting costs, and life-cycle costs). The report also deals with regulatory and insurance issues (building codes, fire protection, insurance provisions) and construction costs for large underground buildings. The report recommends that: (1) the Minnesota Energy Agency consult with the Building Code Division of the Department of Administration on HUD Minimum Property Standards to examine the possibility of modifying several building-code requirements that affect earth-sheltered housing design; (2) HUD Minimum Property Standards be brought into line with the major building codes on the question of optional mechanical ventilation in houses; (3) model ordinances concerning setbacks, basement house provisions, and minimum square footage provisions to be drafted; (4) legal questions concerning the separation of ownership of the surface from that subsurface space be resolved; (5) questions concerning taxation of mined space be resolved; and (6) a life-cost inventory of underground residences and buildings in Minnesota be compiled.

  18. Kombucha brewing under the Food and Drug Administration model Food Code: risk analysis and processing guidance.

    Science.gov (United States)

    Nummer, Brian A

    2013-11-01

    Kombucha is a fermented beverage made from brewed tea and sugar. The taste is slightly sweet and acidic and it may have residual carbon dioxide. Kombucha is consumed in many countries as a health beverage and it is gaining in popularity in the U.S. Consequently, many retailers and food service operators are seeking to brew this beverage on site. As a fermented beverage, kombucha would be categorized in the Food and Drug Administration model Food Code as a specialized process and would require a variance with submission of a food safety plan. This special report was created to assist both operators and regulators in preparing or reviewing a kombucha food safety plan.

  19. ZAKI a windows-based k sub o standardization code for in-core INAA

    CERN Document Server

    Ojo, J O

    2002-01-01

    A new computer code ZAKI, for k sub o -based INAA standardization, written in Visual Basic for the WINDOWS environment is described. The parameter alpha measuring the deviation of the epithermal neutron spectrum shape from the ideal 1/E shape, and the thermal-to-epithermal flux ratio f, are monitored at each irradiation position for each irradiation using the ''triple bare monitor with k sub o '' technique. Stability of the irradiation position with respect to alpha and f is therefore assumed only for the duration of the irradiation. This now makes it possible to use k sub o standardization even for in-core reactor irradiation channels without an a priori knowledge of alpha and f values as required by existing commercial software. ZAKI is considerably versatile and contains features which allow for use of several detectors at different counting geometries, direct inputting of peak search output from GeniePc, and automatic nuclide identification of all gamma lines using an in-built library. Sample results for ...

  20. 78 FR 41183 - Federal Aviation Administration

    Science.gov (United States)

    2013-07-09

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Meeting: RTCA Program Management Committee AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION... Operations Group, Federal Aviation Administration. [FR Doc. 2013-16464 Filed 7-8-13; 8:45 am] BILLING CODE...

  1. The standard genetic code and its relation to mutational pressure: robustness and equilibrium criteria

    International Nuclear Information System (INIS)

    Hernandez Caceres, Jose Luis; Hong, Rolando; Martinez Ortiz, Carlos; Sautie Castellanos, Miguel; Valdes, Kiria; Guevara Erra, Ramon

    2004-10-01

    Under the assumption of even point mutation pressure on the DNA strand, rates for transitions from one amino acid into another were assessed. Nearly 25% of all mutations were silent. About 48% of the mutations from a given amino acid stream either into the same amino acid or into an amino acid of the same class. These results suggest a great stability of the Standard Genetic Code respect to mutation load. Concepts from chemical equilibrium theory are applicable into this case provided that mutation rate constants are given. It was obtained that unequal synonymic codon usage may lead to changes in the equilibrium concentrations. Data from real biological species showed that several amino acids are close to the respective equilibrium concentration. However in all the cases the concentration of leucine nearly doubled its equilibrium concentration, whereas for the stop command (Term) it was about 10 times lower. The overall distance from equilibrium for a set of species suggests that eukaryotes are closer to equilibrium than prokaryotes, and the HIV virus was closest to equilibrium among 15 species. We obtained that contemporary species are closer to the equilibrium than the Last Universal Common Ancestor (LUCA) was. Similarly, nonpreserved regions in proteins are closer to equilibrium than the preserved ones. We suggest that this approach can be useful for exploring some aspects of biological evolution in the framework of Standard Genetic Code properties. (author)

  2. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1994-06-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes. Revision 7 was published in January 1993 and became effective in August 1993. Supplement 1 is being issued primarily to implement administrative changes to the requalification examination program resulting from the amendment to 10 CFR 55 that eliminated the requirement for every licensed operator to pass an NRC-conducted requalification examination as a condition for license renewal. The supplement does not substantially alter either the initial or requalification examination processes and will become effective 30 days after its publication is noticed in the Federal Register. The corporate notification letters issued after the effective date will provide facility licensees with at least 90 days notice that the examinations will be administered in accordance with the revised procedures

  3. RH-TRU Waste Content Codes

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2007-07-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  4. Accounting Education Approach in the Context of New Turkish Commercial Code and Turkish Accounting Standards

    OpenAIRE

    Cevdet Kızıl; Ayşe Tansel Çetin; Ahmed Bulunmaz

    2014-01-01

    The aim of this article is to investigate the impact of new Turkish commercial code and Turkish accounting standards on accounting education. This study takes advantage of the survey method for gathering information and running the research analysis. For this purpose, questionnaire forms are distributed to university students personally and via the internet.This paper includes significant research questions such as “Are accounting academicians informed and knowledgeable on new Turkish commerc...

  5. Overview of North American Hydrogen Sensor Standards

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Kathleen [SRA International, Inc., Colorado Springs, CO (United States); Lopez, Hugo [UL LLC, Chicago, IL (United States); Cairns, Julie [CSA Group, Cleveland, OH (United States); Wichert, Richard [Professional Engineering, Inc.. Citrus Heights, CA (United States); Rivkin, Carl [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-08-11

    An overview of the main North American codes and standards associated with hydrogen safety sensors is provided. The distinction between a code and a standard is defined, and the relationship between standards and codes is clarified, especially for those circumstances where a standard or a certification requirement is explicitly referenced within a code. The report identifies three main types of standards commonly applied to hydrogen sensors (interface and controls standards, shock and hazard standards, and performance-based standards). The certification process and a list and description of the main standards and model codes associated with the use of hydrogen safety sensors in hydrogen infrastructure are presented.

  6. National Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian; Halverson, Mark A.; Myer, Michael; Loper, Susan A.; Richman, Eric E.; Elliott, Douglas B.; Mendon, Vrushali V.; Rosenberg, Michael I.

    2013-11-30

    Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components, initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.

  7. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    2000-01-01

    The International Atomic Energy Agency published in 1987 an International Code of Practice entitled 'Absorbed Dose Determination in Photon and Electron Beams' (IAEA Technical Reports Series No. 277 (TRS-277)), recommending procedures to obtain the absorbed dose in water from measurements made with an ionization chamber in external beam radiotherapy. A second edition of TRS-277 was published in 1997 updating the dosimetry of photon beams, mainly kilovoltage X rays. Another International Code of Practice for radiotherapy dosimetry entitled 'The Use of Plane-Parallel Ionization Chambers in High Energy Electron and Photon Beams' (IAEA Technical Reports Series No. 381 (TRS-381)) was published in 1997 to further update TRS-277 and complement it with respect to the area of parallel-plate ionization chambers. Both codes have proven extremely valuable for users involved in the dosimetry of the radiation beams used in radiotherapy. In TRS-277 the calibration of the ionization chambers was based on primary standards of air kerma; this procedure was also used in TRS-381, but the new trend of calibrating ionization chambers directly in a water phantom in terms of absorbed dose to water was introduced. The development of primary standards of absorbed dose to water for high energy photon and electron beams, and improvements in radiation dosimetry concepts, offer the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. The dosimetry of kilovoltage X rays, as well as that of proton and heavy ion beams, interest in which has grown considerably in recent years, can also be based on these standards. Thus a coherent dosimetry system based on standards of absorbed dose to water is possible for practically all radiotherapy beams. Many Primary Standard Dosimetry Laboratories (PSDLs) already provide calibrations in terms of absorbed dose to water at the radiation quality of 60 Co gamma rays. Some laboratories have extended calibrations to high energy photon and

  8. Building codes : obstacle or opportunity?

    Science.gov (United States)

    Alberto Goetzl; David B. McKeever

    1999-01-01

    Building codes are critically important in the use of wood products for construction. The codes contain regulations that are prescriptive or performance related for various kinds of buildings and construction types. A prescriptive standard might dictate that a particular type of material be used in a given application. A performance standard requires that a particular...

  9. The New Civil Process Code and the Mediation Act: The Incentive to Extrajudicial and Consensual Conflicts Resolution in Public Administration

    Directory of Open Access Journals (Sweden)

    Aline Sueli de Salles Santos

    2016-10-01

    Full Text Available The purpose of this paper is to discuss the contextual aspects of the norm, inserted in the article 174 of the New Civil Process Code and in the Mediation Act, which determines the creation of the chambers of mediation and conciliation, aiming to resolve the consensual and extrajudicial conflict in the public administration. In addition, it will also focuses on the perspectives of that legislative innovation, which tends to produce socially relevant results.

  10. RFQ simulation code

    International Nuclear Information System (INIS)

    Lysenko, W.P.

    1984-04-01

    We have developed the RFQLIB simulation system to provide a means to systematically generate the new versions of radio-frequency quadrupole (RFQ) linac simulation codes that are required by the constantly changing needs of a research environment. This integrated system simplifies keeping track of the various versions of the simulation code and makes it practical to maintain complete and up-to-date documentation. In this scheme, there is a certain standard version of the simulation code that forms a library upon which new versions are built. To generate a new version of the simulation code, the routines to be modified or added are appended to a standard command file, which contains the commands to compile the new routines and link them to the routines in the library. The library itself is rarely changed. Whenever the library is modified, however, this modification is seen by all versions of the simulation code, which actually exist as different versions of the command file. All code is written according to the rules of structured programming. Modularity is enforced by not using COMMON statements, simplifying the relation of the data flow to a hierarchy diagram. Simulation results are similar to those of the PARMTEQ code, as expected, because of the similar physical model. Different capabilities, such as those for generating beams matched in detail to the structure, are available in the new code for help in testing new ideas in designing RFQ linacs

  11. Framework for Establishment of a Comprehensive and Standardized Administration System for Prevention and Control of Tuberculosis in College Student Community in China.

    Science.gov (United States)

    Zhang, Shaoru; Li, Xiaohong; Zhang, Tianhua; Wang, Xiangni; Liu, Weiping; Ma, Xuexue; Li, Yuelu; Fan, Yahui

    2016-10-01

    College student community is the one with high risk of tuberculosis (TB). A systemic and standardized administration model for prevention and control of TB is significance in controlling TB spread in universities. Currently, the universities in China have not established the comprehensive and standardized administration system for TB prevention and control in college student community. Firstly, the literature research and brainstorming method (n=13) were used to construct the clause and sub-clause pool for the administration of TB prevention and control within college student community in 2014. Secondly, a total of twenty experts in the field of TB prevention and control who are representatives of the east, west, south and north parts of China were selected and invited to participate the Delphi letter-inquiry. After two rounds of letter-inquiry, the opinions of the experts reached a consensus and the framework for the administration system was constructed. A framework for the administration system was constructed, which included 8 first class indexes, 26 second class indexes and 104 third class indexes. The results are highly scientific and reliable, which can be helpful for improving the systemic and standardized levels for the administration of TB prevention and control in universities in China and perhaps in other developing counties with high TB burden as well.

  12. Coding in Stroke and Other Cerebrovascular Diseases.

    Science.gov (United States)

    Korb, Pearce J; Jones, William

    2017-02-01

    Accurate coding is critical for clinical practice and research. Ongoing changes to diagnostic and billing codes require the clinician to stay abreast of coding updates. Payment for health care services, data sets for health services research, and reporting for medical quality improvement all require accurate administrative coding. This article provides an overview of coding principles for patients with strokes and other cerebrovascular diseases and includes an illustrative case as a review of coding principles in a patient with acute stroke.

  13. Validity of vascular trauma codes at major trauma centres.

    Science.gov (United States)

    Altoijry, Abdulmajeed; Al-Omran, Mohammed; Lindsay, Thomas F; Johnston, K Wayne; Melo, Magda; Mamdani, Muhammad

    2013-12-01

    The use of administrative databases in vascular injury research has been increasing, but the validity of the diagnosis codes used in this research is uncertain. We assessed the positive predictive value (PPV) of International Classification of Diseases, tenth revision (ICD-10), vascular injury codes in administrative claims data in Ontario. We conducted a retrospective validation study using the Canadian Institute for Health Information Discharge Abstract Database, an administrative database that records all hospital admissions in Canada. We evaluated 380 randomly selected hospital discharge abstracts from the 2 main trauma centres in Toronto, Ont., St.Michael's Hospital and Sunnybrook Health Sciences Centre, between Apr. 1, 2002, and Mar. 31, 2010. We then compared these records with the corresponding patients' hospital charts to assess the level of agreement for procedure coding. We calculated the PPV and sensitivity to estimate the validity of vascular injury diagnosis coding. The overall PPV for vascular injury coding was estimated to be 95% (95% confidence interval [CI] 92.3-96.8). The PPV among code groups for neck, thorax, abdomen, upper extremity and lower extremity injuries ranged from 90.8 (95% CI 82.2-95.5) to 97.4 (95% CI 91.0-99.3), whereas sensitivity ranged from 90% (95% CI 81.5-94.8) to 98.7% (95% CI 92.9-99.8). Administrative claims hospital discharge data based on ICD-10 diagnosis codes have a high level of validity when identifying cases of vascular injury. Observational Study Level III.

  14. AECL international standard problem ISP-41 FU/1 follow-up exercise (Phase 1): Containment Iodine Computer Code Exercise: Parametric Studies

    International Nuclear Information System (INIS)

    Ball, J.; Glowa, G.; Wren, J.; Ewig, F.; Dickenson, S.; Billarand, Y.; Cantrel, L.; Rydl, A.; Royen, J.

    2001-06-01

    This report describes the results of the second phase of International Standard Problem (ISP) 41, an iodine behaviour code comparison exercise. The first phase of the study, which was based on a simple Radioiodine Test Facility (RTF) experiment, demonstrated that all of the iodine behaviour codes had the capability to reproduce iodine behaviour for a narrow range of conditions (single temperature, no organic impurities, controlled pH steps). The current phase, a parametric study, was designed to evaluate the sensitivity of iodine behaviour codes to boundary conditions such as pH, dose rate, temperature and initial I- concentration. The codes used in this exercise were IODE (IPSN), IODE (NRIR), IMPAIR (GRS), INSPECT (AEAT), IMOD (AECL) and LIRIC (AECL). The parametric study described in this report identified several areas of discrepancy between the various codes. In general, the codes agree regarding qualitative trends, but their predictions regarding the actual amount of volatile iodine varied considerably. The largest source of the discrepancies between code predictions appears to be their different approaches to modelling the formation and destruction of organic iodides. A recommendation arising from this exercise is that an additional code comparison exercise be performed on organic iodide formation, against data obtained from intermediate-scale studies (two RTF (AECL, Canada) and two CAIMAN facility (IPSN, France) experiments have been chosen). This comparison will allow each of the code users to realistically evaluate and improve the organic iodide behaviour sub-models within their codes. (authors)

  15. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    Science.gov (United States)

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  16. Application of NEA/CSNI standard problem 3 (blowdown and flow reversal in the IETA-1 rig) to the validation of the RELAP-UK Mk IV code

    International Nuclear Information System (INIS)

    Bryce, W.M.

    1977-10-01

    NEA/CSNI Standard Problem 3 consists of the modelling of an experiment on the IETI-1 rig, in which there is initially flow upwards through a feeder, heated section and riser. The inlet and outlet are then closed and a breach opened at the bottom so that the flow reverses and the rig depressurises. Calculations of this problem by many countries using several computer codes have been reported and show a wide spread of results. The purpose of the study reported here was the following. First, to show the sensitivity of the calculation of Standard Problem 3. Second, to perform an ab initio best estimate calculation using the RELAP-UK Mark IV code with the standard recommended options, and third, to use the results of the sensitivity study to show where tuning of the RELAP-UK Mark IV recommended model options was required. This study has shown that the calculation of Standard Problem 3 is sensitive to model assumptions and that the use of the loss-of-coolant accident code RELAP-UK Mk IV with the standard recommended model options predicts the experimental results very well over most of the transient. (U.K.)

  17. Non-Power Reactor Operator Licensing Examiner Standards. Revision 1

    International Nuclear Information System (INIS)

    1995-06-01

    The Non-Power Reactor Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience

  18. Non-Power Reactor Operator Licensing Examiner Standards. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    The Non-Power Reactor Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience.

  19. A Life-Cycle Risk-Informed Systems Structured Nuclear Code

    International Nuclear Information System (INIS)

    Hill, Ralph S. III

    2002-01-01

    Current American Society of Mechanical Engineers (ASME) nuclear codes and standards rely primarily on deterministic and mechanistic approaches to design. The design code is a separate volume from the code for inservice inspections and both are separate from the standards for operations and maintenance. The ASME code for inservice inspections and code for nuclear plant operations and maintenance have adopted risk-informed methodologies for inservice inspection, preventive maintenance, and repair and replacement decisions. The American Institute of Steel Construction and the American Concrete Institute have incorporated risk-informed probabilistic methodologies into their design codes. It is proposed that the ASME nuclear code should undergo a planned evolution that integrates the various nuclear codes and standards and adopts a risk-informed approach across a facility life-cycle - encompassing design, construction, operation, maintenance and closure. (author)

  20. Reactor lattice codes

    International Nuclear Information System (INIS)

    Kulikowska, T.

    1999-01-01

    The present lecture has a main goal to show how the transport lattice calculations are realised in a standard computer code. This is illustrated on the example of the WIMSD code, belonging to the most popular tools for reactor calculations. Most of the approaches discussed here can be easily modified to any other lattice code. The description of the code assumes the basic knowledge of reactor lattice, on the level given in the lecture on 'Reactor lattice transport calculations'. For more advanced explanation of the WIMSD code the reader is directed to the detailed descriptions of the code cited in References. The discussion of the methods and models included in the code is followed by the generally used homogenisation procedure and several numerical examples of discrepancies in calculated multiplication factors based on different sources of library data. (author)

  1. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules, F9-F11

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with three of the functional modules in the code. Those are the Morse-SGC for the SCALE system, Heating 7.2, and KENO V.a. The manual describes the latest released versions of the codes.

  2. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules, F9-F11

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with three of the functional modules in the code. Those are the Morse-SGC for the SCALE system, Heating 7.2, and KENO V.a. The manual describes the latest released versions of the codes

  3. An evaluation of the effectiveness of the EPA comply code to demonstrate compliance with radionuclide emission standards at three manufacturing facilities

    International Nuclear Information System (INIS)

    Smith, L.R.; Laferriere, J.R.; Nagy, J.W.

    1991-01-01

    Measurements of airborne radionuclide emissions and associated environmental concentrations were made at, and in the vicinity of, two urban and one suburban facility where radiolabeled chemicals for biomedical research and radiopharmaceuticals are manufactured. Emission, environmental and meteorological measurements were used in the EPA COMPLY code and in environmental assessment models developed specifically for these sites to compare their ability to predict off-site measurements. The models and code were then used to determine potential dose to hypothetical maximally exposed receptors and the ability of these methods to demonstrate whether these facilities comply with proposed radionuclide emission standards assessed. In no case did the models and code seriously underestimate off-site impacts. However, for certain radionuclides and chemical forms, the EPA COMPLY code was found to overestimate off-site impacts by such a large factor as to render its value questionable for determining regulatory compliance. Recommendations are offered for changing the code to enable it to be more serviceable to radionuclide users and regulators

  4. Review and evaluation of technology, equipment, codes and standards for digitization of industrial radiographic film

    International Nuclear Information System (INIS)

    1992-05-01

    This reports contains a review and evaluation of the technology, equipment, and codes and standards related to the digitization of industrial radiographic film. The report presents recommendations and equipment-performance specifications that will allow the digitization of radiographic film from nuclear power plant components in order to produce faithful reproductions of flaw images of interest on the films. Justification for the specifications selected are provided. Performance demonstration tests for the digitization process are required and criteria for such tests is presented. Also several comments related to implementation of the technology are presented and discussed

  5. Accuracy of administrative data for identification of patients with infective endocarditis.

    Science.gov (United States)

    Tan, Charlie; Hansen, Mark; Cohen, Gideon; Boyle, Karl; Daneman, Nick; Adhikari, Neill K J

    2016-12-01

    Infective endocarditis is associated with high morbidity and mortality rates that have plateaued over recent decades. Research to improve outcomes for these patients is limited by the rarity of this condition. Therefore, we sought to validate administrative database codes for the diagnosis of infective endocarditis. We conducted a retrospective validation study of International Classification of Diseases (ICD-10-CM) codes for infective endocarditis against clinical Duke criteria (definite and probable) at a large acute care hospital between October 1, 2013 and June 30, 2015. To identify potential cases missed by ICD-10-CM codes, we also screened the hospital's valvular heart surgery database and the microbiology laboratory database (the latter for patients with bacteremia due to organisms commonly causing endocarditis). Using definite Duke criteria or probable criteria with clinical suspicion as the reference standard, the ICD-10-CM codes had a sensitivity (SN) of 0.90 (95% confidence interval (CI), 0.81-0.95), specificity (SP) of 1 (95% CI, 1-1), positive predictive value (PPV) of 0.78 (95% CI, 0.68-0.85) and negative predictive value (NPV) of 1 (95% CI, 1-1). Restricting the case definition to definite Duke criteria resulted in an increase in SN to 0.95 (95% CI, 0.86-0.99) and a decrease in PPV to 0.6 (95% CI, 0.49-0.69), with no change in specificity. ICD-10-CM codes can accurately identify patients with infective endocarditis, and so administrative databases offer a potential means to study this infection over large jurisdictions, and thereby improve the prediction, diagnosis, treatment and prevention of this rare but serious infection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Revision of Ethical Standard 3.04 of the "Ethical Principles of Psychologists and Code of Conduct" (2002, as amended 2010).

    Science.gov (United States)

    2016-12-01

    The following amendment to Ethical Standard 3.04 of the 2002 "Ethical Principles of Psychologists and Code of Conduct" as amended, 2010 (the Ethics Code; American Psychological Association, 2002, 2010) was adopted by the APA Council of Representatives at its August 2016 meeting. The amendment will become effective January 1, 2017. Following is an explanation of the change, a clean version of the revision, and a version indicating changes from the 2002 language (inserted text is in italics). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  7. ISPOR Code of Ethics 2017 (4th Edition).

    Science.gov (United States)

    Santos, Jessica; Palumbo, Francis; Molsen-David, Elizabeth; Willke, Richard J; Binder, Louise; Drummond, Michael; Ho, Anita; Marder, William D; Parmenter, Louise; Sandhu, Gurmit; Shafie, Asrul A; Thompson, David

    2017-12-01

    As the leading health economics and outcomes research (HEOR) professional society, ISPOR has a responsibility to establish a uniform, harmonized international code for ethical conduct. ISPOR has updated its 2008 Code of Ethics to reflect the current research environment. This code addresses what is acceptable and unacceptable in research, from inception to the dissemination of its results. There are nine chapters: 1 - Introduction; 2 - Ethical Principles respect, beneficence and justice with reference to a non-exhaustive compilation of international, regional, and country-specific guidelines and standards; 3 - Scope HEOR definitions and how HEOR and the Code relate to other research fields; 4 - Research Design Considerations primary and secondary data related issues, e.g., participant recruitment, population and research setting, sample size/site selection, incentive/honorarium, administration databases, registration of retrospective observational studies and modeling studies; 5 - Data Considerations privacy and data protection, combining, verification and transparency of research data, scientific misconduct, etc.; 6 - Sponsorship and Relationships with Others (roles of researchers, sponsors, key opinion leaders and advisory board members, research participants and institutional review boards (IRBs) / independent ethics committees (IECs) approval and responsibilities); 7 - Patient Centricity and Patient Engagement new addition, with explanation and guidance; 8 - Publication and Dissemination; and 9 - Conclusion and Limitations. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. RH-TRU Waste Content Codes (RH TRUCON)

    International Nuclear Information System (INIS)

    2007-01-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. (2) A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is ''3''. The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  9. RH-TRU Waste Content Codes (RH TRUCON)

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2007-05-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  10. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Control modules C4, C6

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U. S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume is part of the manual related to the control modules for the newest updated version of this computational package.

  11. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Halverson, Mark A.; Richman, Eric E.; Winiarski, David W.

    2002-09-30

    The state of Michigan is considering adpoting ASHRAE 90.1-1999 as its commercial building energy code. In an effort to evaluate whether or not this is an appropraite code for the state, the potential benefits and costs of adopting this standard are considered. Both qualitative and quantitative benefits are assessed. The energy simulation and economic results suggest that adopting ASHRAE 90.1-1999 would provide postitive net benefits to the state relative to the building and design requirements currently in place.

  12. Iterative demodulation and decoding of coded non-square QAM

    Science.gov (United States)

    Li, L.; Divsalar, D.; Dolinar, S.

    2003-01-01

    Simulation results show that, with iterative demodulation and decoding, coded NS-8QAM performs 0.5 dB better than standard 8QAM and 0.7 dB better than 8PSK at BER= 10(sup -5), when the FEC code is the (15, 11) Hamming code concatenated with a rate-1 accumulator code, while coded NS-32QAM performs 0.25 dB better than standard 32QAM.

  13. 45 CFR 162.1002 - Medical data code sets.

    Science.gov (United States)

    2010-10-01

    ... Terminology, Fourth Edition (CPT-4), as maintained and distributed by the American Medical Association, for... 45 Public Welfare 1 2010-10-01 2010-10-01 false Medical data code sets. 162.1002 Section 162.1002... REQUIREMENTS ADMINISTRATIVE REQUIREMENTS Code Sets § 162.1002 Medical data code sets. The Secretary adopts the...

  14. Under-coding of secondary conditions in coded hospital health data: Impact of co-existing conditions, death status and number of codes in a record.

    Science.gov (United States)

    Peng, Mingkai; Southern, Danielle A; Williamson, Tyler; Quan, Hude

    2017-12-01

    This study examined the coding validity of hypertension, diabetes, obesity and depression related to the presence of their co-existing conditions, death status and the number of diagnosis codes in hospital discharge abstract database. We randomly selected 4007 discharge abstract database records from four teaching hospitals in Alberta, Canada and reviewed their charts to extract 31 conditions listed in Charlson and Elixhauser comorbidity indices. Conditions associated with the four study conditions were identified through multivariable logistic regression. Coding validity (i.e. sensitivity, positive predictive value) of the four conditions was related to the presence of their associated conditions. Sensitivity increased with increasing number of diagnosis code. Impact of death on coding validity is minimal. Coding validity of conditions is closely related to its clinical importance and complexity of patients' case mix. We recommend mandatory coding of certain secondary diagnosis to meet the need of health research based on administrative health data.

  15. The Ontario Energy Board`s draft standard supply service code: effects on air quality

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J.; Bjorkquist, S. [Ontario Clean Air Alliance, Toronto, ON (Canada)

    1999-06-29

    The Ontario Clean Air Alliance (OCAA), a coalition of 67 organizations, takes issue with the Ontario Energy Board`s draft document `Standard Supply Service Code`, particularly sections 2.2.2. and 2.5.2 which they claim are not in the public interest unless the Ontario government implements the OCAA`s recommended emission caps. The alliance is of the view that without strict new environmental regulations the proposed Code would encourage the use of coal for electricity generation. Public health, the environment, consumer interests, job creation and promotion of a competitive electricity market would all be jeopardized by this development, the alliance states. The argument is supported by extensive reference to the Final Report of the Ontario Market Design Committee (MDC) which also emphasized the importance of combining the introduction of competition with appropriate environmental regulations, singling out the emission cap and trade program, and recommending that it be launched concurrently with the electricity market opening for competition. The view of the MDC was that public support for restructuring would not be forthcoming in the absence of regulatory measures to control power plant emissions. 25 refs.

  16. The Code of Ethics and Editorial Code of Practice of the Royal Astronomical Society

    Science.gov (United States)

    Murdin, Paul

    2013-01-01

    Whilst the Royal Astronomical Society has got by for more than 100 years without a written code of ethics, modern standards of governance suggested that such a code could be useful in the resolution of disputes. In 2005, the RAS adopted the Universal Code of Ethics for Science that had been formulated by the Royal Society of London. At the same time and for similar reasons the RAS adopted an Editorial Code of Practice.

  17. 21 CFR 610.67 - Bar code label requirements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Bar code label requirements. 610.67 Section 610.67...) BIOLOGICS GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.67 Bar code label requirements. Biological products must comply with the bar code requirements at § 201.25 of this chapter. However, the bar...

  18. Error-Detecting Identification Codes for Algebra Students.

    Science.gov (United States)

    Sutherland, David C.

    1990-01-01

    Discusses common error-detecting identification codes using linear algebra terminology to provide an interesting application of algebra. Presents examples from the International Standard Book Number, the Universal Product Code, bank identification numbers, and the ZIP code bar code. (YP)

  19. SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 1, Part 2: Control modules S1--H1; Revision 5

    International Nuclear Information System (INIS)

    1997-03-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system

  20. SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 2, Part 3: Functional modules F16--F17; Revision 5

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system.

  1. SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 2, Part 3: Functional modules F16--F17; Revision 5

    International Nuclear Information System (INIS)

    1997-03-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system

  2. Overview of the U.S. DOE Hydrogen Safety, Codes and Standards Program. Part 4: Hydrogen Sensors; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J.; Rivkin, Carl; Burgess, Robert; Brosha, Eric; Mukundan, Rangachary; James, C. Will; Keller, Jay

    2016-12-01

    Hydrogen sensors are recognized as a critical element in the safety design for any hydrogen system. In this role, sensors can perform several important functions including indication of unintended hydrogen releases, activation of mitigation strategies to preclude the development of dangerous situations, activation of alarm systems and communication to first responders, and to initiate system shutdown. The functionality of hydrogen sensors in this capacity is decoupled from the system being monitored, thereby providing an independent safety component that is not affected by the system itself. The importance of hydrogen sensors has been recognized by DOE and by the Fuel Cell Technologies Office's Safety and Codes Standards (SCS) program in particular, which has for several years supported hydrogen safety sensor research and development. The SCS hydrogen sensor programs are currently led by the National Renewable Energy Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory. The current SCS sensor program encompasses the full range of issues related to safety sensors, including development of advance sensor platforms with exemplary performance, development of sensor-related code and standards, outreach to stakeholders on the role sensors play in facilitating deployment, technology evaluation, and support on the proper selection and use of sensors.

  3. The path of code linting

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Join the path of code linting and discover how it can help you reach higher levels of programming enlightenment. Today we will cover how to embrace code linters to offload cognitive strain on preserving style standards in your code base as well as avoiding error-prone constructs. Additionally, I will show you the journey ahead for integrating several code linters in the programming tools your already use with very little effort.

  4. Radon in the Workplace: the Occupational Safety and Health Administration (OSHA) Ionizing Radiation Standard.

    Science.gov (United States)

    Lewis, Robert K

    2016-10-01

    On 29 December 1970, the Occupational Safety and Health Act of 1970 established the Occupational Safety and Health Administration (OSHA). This article on OSHA, Title 29, Part 1910.1096 Ionizing Radiation standard was written to increase awareness of the employer, the workforce, state and federal governments, and those in the radon industry who perform radon testing and radon mitigation of the existence of these regulations, particularly the radon relevant aspect of the regulations. This review paper was also written to try to explain what can sometimes be complicated regulations. As the author works within the Radon Division of the Pennsylvania Department of Environmental Protection, Bureau of Radiation Protection, the exclusive focus of the article is on radon. The 1910.1096 standard obviously covers many other aspects of radiation and radiation safety in the work place.

  5. 75 FR 61552 - Federal Railroad Administration

    Science.gov (United States)

    2010-10-05

    ... DEPARTMENT OF TRANSPORTATION Federal Railroad Administration Notice of Informational Filing In accordance with Section 236.913 of Title 49 of the Code of Federal Regulations (CFR), notice is hereby given that the Federal Railroad Administration (FRA) has received an informational filing from the Northeast...

  6. Study on Establishing Standard Administrative Report Guidelines for KAERI

    International Nuclear Information System (INIS)

    Koo, Hwang Duk; Cho, Woo Sung; Lee, Bong Jae

    2012-12-01

    Ο The main purpose of administrative report of an organization is to deliver a critical mind about surrounding circumstance and rational alternatives to a final decision maker Ο An established report system with unified formality and systematic concept playes critical role to make right decision and efficient review about pending issues Ο By understanding current situation of report system using in KAERI and analysing examples of other organization, we established specific administrative report writing guideline for KAERI Ο We expect efficient communication and increasing productivity from the guideline by establishing and diffusing administrative report common writing guideline reflecting longstanding administrative experience and know-how of a specialized committeeman of KAERI

  7. Study on Establishing Standard Administrative Report Guidelines for KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Hwang Duk; Cho, Woo Sung; Lee, Bong Jae

    2012-12-15

    Ο The main purpose of administrative report of an organization is to deliver a critical mind about surrounding circumstance and rational alternatives to a final decision maker Ο An established report system with unified formality and systematic concept playes critical role to make right decision and efficient review about pending issues Ο By understanding current situation of report system using in KAERI and analysing examples of other organization, we established specific administrative report writing guideline for KAERI Ο We expect efficient communication and increasing productivity from the guideline by establishing and diffusing administrative report common writing guideline reflecting longstanding administrative experience and know-how of a specialized committeeman of KAERI.

  8. 76 FR 65183 - National Oceanic and Atmospheric Administration

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National Climate Assessment... Oceanic and Atmospheric Administration (NOAA), Department of Commerce (DOC). ACTION: Notice of open..., National Oceanic and Atmospheric Administration. [FR Doc. 2011-27113 Filed 10-19-11; 8:45 am] BILLING CODE...

  9. Grid Standards and Codes | Grid Modernization | NREL

    Science.gov (United States)

    photovoltaics (PV) adoption have given a sense of urgency to the standards development process. The Accelerating Systems Integration Standards team is addressing this urgency by providing leadership and direction for

  10. QUIC: a chemical kinetics code for use with the chemical equilibrium code QUIL

    International Nuclear Information System (INIS)

    Lunsford, J.L.

    1977-10-01

    A chemical rate kinetics code QUIC is described, along with a support code RATE. QUIC is designed to allow chemical kinetics calculations on a wide variety of chemical environments while operating in the overlay environment of the chemical equilibrium code QUIL. QUIC depends upon a rate-data library called LIBR. This library is maintained by RATE. RATE enters into the library all reactions in a standardized format. The code QUIC, operating in conjunction with QUIL, is interactive and written to be used from a remote terminal, with paging control provided. Plotted output is also available

  11. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Illinois Jurisdictions

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.; Cort, Katherine A.; Winiarski, David W.; Richman, Eric E.; Friedrich, Michele

    2002-05-01

    ASHRAE Standard 90.1-1999 was developed in an effort to set minimum requirements for energy efficienty design and construction of new commercial buildings. This report assesses the benefits and costs of adopting this standard as the building energy code in Illinois. Energy and economic impacts are estimated using BLAST combined with a Life-Cycle Cost approach to assess corresponding economic costs and benefits.

  12. FDA Developments: Food Code 2013 and Proposed Trans Fat Determination

    NARCIS (Netherlands)

    Grossman, M.R.

    2014-01-01

    268 Reports EFFL 4|2014 USA FDA Developments: Food Code 2013 and Proposed Trans Fat Determination Margaret Rosso Grossman* I. Food Code 2013 and Food Code Reference System Since 1993, the US Food and Drug Administration has published a Food Code, now updated every four years. In November 2013, the

  13. Current and proposed revisions, changes, and modifications to American codes and standards to address packaging, handling, and transportation of radioactive materials and how they relate to comparable international regulations

    International Nuclear Information System (INIS)

    Borter, W.H.; Froehlich, C.H.

    2004-01-01

    This paper addresses current and proposed revisions, additions, and modifications to American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) (i.e., ''ASMEthe Code'') Section III, Division 3 and American National Standards Institute (ANSI)/ASME N14.6. It provides insight into the ongoing processes of the associated committees and highlights important revisions, changes, and modifications to this Code and Standard. The ASME Code has developed and issued Division 3 to address items associated with the transportation and storage of radioactive materials. It currently only addresses ''General Requirements'' in Subsections WA and ''Class TP (Type B) Containments'' (Transportation Packages) in Subsection WB, but is in the process of adding a new Subsection WC to address ''Class SC'' (Storage Containments). ANSI/ASME Standard N14.6 which interacts with components constructed to Division 3 by addressinges special lifting devices for radioactive material shipping containers. This Standard is in the process of a complete re-write. This Code and Standard can be classified as ''dynamic'' in that their committees meet at least four times a year to evaluate proposed modifications and additions that reflect current safety practices in the nuclear industry. These evaluations include the possible addition of new materials, fabrication processes, examination methods, and testing requirements. An overview of this ongoing process is presented in this paper along with highlights of the more important proposed revisions, changes, and modifications and how they relate to United States (US) and international regulations and guidance like International Atomic Energy Agency (IAEA) Requirement No. TS-R-1

  14. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules F1-F8

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with eight of the functional modules in the code. Those are: BONAMI - resonance self-shielding by the Bondarenko method; NITAWL-II - SCALE system module for performing resonance shielding and working library production; XSDRNPM - a one-dimensional discrete-ordinates code for transport analysis; XSDOSE - a module for calculating fluxes and dose rates at points outside a shield; KENO IV/S - an improved monte carlo criticality program; COUPLE; ORIGEN-S - SCALE system module to calculate fuel depletion, actinide transmutation, fission product buildup and decay, and associated radiation source terms; ICE

  15. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules F1-F8

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with eight of the functional modules in the code. Those are: BONAMI - resonance self-shielding by the Bondarenko method; NITAWL-II - SCALE system module for performing resonance shielding and working library production; XSDRNPM - a one-dimensional discrete-ordinates code for transport analysis; XSDOSE - a module for calculating fluxes and dose rates at points outside a shield; KENO IV/S - an improved monte carlo criticality program; COUPLE; ORIGEN-S - SCALE system module to calculate fuel depletion, actinide transmutation, fission product buildup and decay, and associated radiation source terms; ICE.

  16. Electronic Code of Federal Regulations

    Data.gov (United States)

    National Archives and Records Administration — The Electronic Code of Federal Regulations (e-CFR) is the codification of the general and permanent rules published in the Federal Register by the executive...

  17. RH-TRU Waste Content Codes (RH-Trucon)

    International Nuclear Information System (INIS)

    2007-01-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is '3.' The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR limits based

  18. RH-TRU Waste Content Codes (RH-TRUCON)

    International Nuclear Information System (INIS)

    2007-01-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is '3.' The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR limits based

  19. RH-TRU Waste Content Codes (RH-TRUCON)

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2007-08-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  20. RH-TRU Waste Content Codes (RH-TRUCON)

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2007-05-30

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC).1 The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: • A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. • A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is “3.” The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  1. The Canadian approach to nuclear codes and standards. A CSA forum for development of standards for CANDU: radioactive waste management and decommissioning

    International Nuclear Information System (INIS)

    Shin, T.; Azeez, S.; Dua, S.

    2006-01-01

    Together with the Canadian Standards Association (CSA), industry stakeholders, governments, and the public have developed a suite of standards for CANDU nuclear power plants that generate electricity in Canada and abroad. In this paper, we will describe: CSA's role in national and international nuclear standards development; the key issues and priority projects that the nuclear standards program has addressed; the new CSA nuclear committees and projects being established, particularly those related to waste management and decommissioning; the hierarchy of nuclear regulations, nuclear, and other standards in Canada, and how they are applied by AECL; the standards management activities; and the future trends and challenges for CSA and the nuclear community. CSA is an accredited Standards Development Organization (SDO) and part of the international standards system. CSA's Nuclear Strategic Steering Committee (NSSC) provides leadership, direction, and support for a standards committee hierarchy comprised of members from a balanced matrix of interests. The NSSC strategically focuses on industry challenges; a new nuclear regulatory system, deregulated energy markets, and industry restructuring. As the first phase of priority projects is nearing completion, the next phase of priorities is being identified. These priorities address radioactive waste management, environmental radiation management, decommissioning, structural, and seismic issues. As the CSA committees get established in the coming year, members and input will be solicited for the technical committees, subcommittees, and task forces for the following related subjects: Radioactive Waste Management; a) Dry Storage of Irradiated Fuel; b) Short-Term Radioactive Waste Management; c) Long-Term Storage and Disposal of Radioactive Waste. 2. Decommissioning Nuclear Power is highly regulated, and public scrutiny has focused Codes and Standards on public and worker safety. Licensing and regulation serves to control

  2. Remote-Handled Transuranic Waste Content Codes (RH-Trucon)

    International Nuclear Information System (INIS)

    2006-01-01

    The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) A two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]). The site-specific letter designations for each of the sites are provided in Table 1. (2) A three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is ''3''. The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Table 2 provides a brief description of each generic code. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code. If a site implements the administrative controls outlined in the RH-TRAMPAC and Appendix 2.4 of the RH-TRU Payload Appendices, the decay heat or FGGR

  3. EMPLACEMENT GANTRY ITS STANDARDS IDENTIFICATION STUDY

    International Nuclear Information System (INIS)

    Voegele, M.

    2005-01-01

    To date, the project has established ITS performance requirements for SSCs based on identification and categorization of event sequences that may result in a radiological release. These performance requirements are defined within the NSDB. Further, SSCs credited with performing safe functions are classified as ITS. In turn, perform confirmation for these SSCs is sought through the use of consensus code and standards. The purpose of this study is to identify applicable codes and standards for the WP Emplacement Gantry ITS SSCs. Further, this study will form the basis for selection and the extent of applicability of each code and standard. This study is based on the design development completed for LA only. Accordingly, identification of ITS SSCs beyond those defined within the NSDB are based on designs that may be subject to further development during detail design. Furthermore, several design alternatives may still be under consideration to satisfy certain safety functions, and that final selection will not be determined until further design development has occurred. Therefore, for completeness, throughout this study alternative designs currently under considered will be discussed. Further, the results of this study will be subject to evaluation as part of a follow-on GAP analysis study. Based on the results of this study the GAP analysis will evaluate each code and standard to ensure each ITS performance requirement is fully satisfied. When a performance requirement is not fully satisfied a ''gap'' is highlighted. Thereafter, the study will identify supplemental requirements to augment the code or standard to meet performance requirements. Further, the GAP analysis will identify non-standard areas of the design that will be subject to a Development Plan. Non-standard components and non-standard design configurations are defined as areas of the design that do not follow standard industry practices or codes and standards. Whereby, performance confirmation cannot be

  4. Review of provisions on corrosion fatigue and stress corrosion in WWER and Western LWR Codes and Standards

    International Nuclear Information System (INIS)

    Buckthorpe, D.; Filatov, V.; Tashkinov, A.; Evropin, S.V.; Matocha, K.; Guinovart, J.

    2003-01-01

    Results are presented from a collaborative project performed on behalf of the European Commission, Working Group Codes and Standards. The work covered the contents of current codes and standards, plant experience and R and D results. Current fatigue design rules use S-N curves based on tests in air. Although WWER and LWR design curves are often similar they are derived, presented and used in different ways and it is neither convenient nor appropriate to harmonise them. Similarly the fatigue crack growth laws used in the various design and in-service inspection rules differ significantly with respect to both growth rates in air and the effects of water reactor environments. Harmonised approaches to the effects of WWER and LWR environments are possible based on results from R and D programmes carried out over the last decade. For carbon and low alloy steels a consistent approach to both crack initiation and growth can be formulated based on the superposition of environmentally assisted cracking effects on the fatigue crack development. The approach indicates that effects of the water environment are minimal given appropriate control of the oxygen content of the water and/or the sulphur content of the steel. For austenitic stainless steels a different mechanisms may apply and a harmonised approach is possible at present only for S-N curves. Although substantial progress has been made with respect to corrosion fatigue, more data and a clearer understanding are required in order to write code provisions particularly in the area of high cycle fatigue. Reactor operation experience shows stress corrosion cracking of austenitic steels is the most common cause of failure. These failures are associated with high residual stresses combined with high levels of dissolved oxygen or the presence of contaminants. For primary circuit internals there is a potential threat to integrity from irradiated assisted stress corrosion cracking. Design and in-service inspection rules do not at

  5. 41 CFR 128-1.8005 - Seismic safety standards.

    Science.gov (United States)

    2010-07-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  6. The WIMS familly of codes

    International Nuclear Information System (INIS)

    Askew, J.

    1981-01-01

    WIMS-D4 is the latest version of the original form of the Winfrith Improved Multigroup Scheme, developed in 1963-5 for lattice calculations on all types of thermal reactor, whether moderated by graphite, heavy or light water. The code, in earlier versions, has been available from the NEA code centre for a number of years in both IBM and CDC dialects of FORTRAN. An important feature of this code was its rapid, accurate deterministic system for treating resonance capture in heavy nuclides, and capable of dealing with both regular pin lattices and with cluster geometries typical of pressure tube and gas cooled reactors. WIMS-E is a compatible code scheme in which each calcultation step is bounded by standard interfaces on disc or tape. The interfaces contain files of information in a standard form, restricted to numbers representing physically meaningful quantities such as cross-sections and fluxes. Restriction of code intercommunication to this channel limits the possible propagation of errors. A module is capable of transforming WIMS-D output into the standard interface form and hence the two schemes can be linked if required. LWR-WIMS was developed in 1970 as a method of calculating LWR reloads for the fuel fabricators BNFL/GUNF. It uses the WIMS-E library and a number of the same module

  7. 106-17 Telemetry Standards Front Matter

    Science.gov (United States)

    2017-07-01

    Frequency Division Multiplexing Telemetry Standards CHAPTER 4: Pulse Code Modulation Standards CHAPTER 5: Digitized Audio Telemetry Standard CHAPTER 6...Transfer Standard Chapter 9, Appendix 9-A Appendix I, Telemetry Attributes Transfer Standard Cover Sheet Chapter 9, Appendix 9-B Telemetry Standards...Derived Parameter Specification Chapter 9, Appendix 9-E Appendix Q, Extended Binary Golay Code Chapter 7, Appendix 7-A Appendix R, Low-Density Parity

  8. 21 CFR 201.25 - Bar code label requirements.

    Science.gov (United States)

    2010-04-01

    ... Number/Uniform Code Council (EAN.UCC) or Health Industry Business Communications Council (HIBCC... alternative regulatory program or method of product use renders the bar code unnecessary for patient safety... Evaluation and Research, Food and Drug Administration, 5600 Fishers Lane, Rockville, MD 20857 (requests...

  9. System Based Code: Principal Concept

    International Nuclear Information System (INIS)

    Yasuhide Asada; Masanori Tashimo; Masahiro Ueta

    2002-01-01

    This paper introduces a concept of the 'System Based Code' which has initially been proposed by the authors intending to give nuclear industry a leap of progress in the system reliability, performance improvement, and cost reduction. The concept of the System Based Code intends to give a theoretical procedure to optimize the reliability of the system by administrating every related engineering requirement throughout the life of the system from design to decommissioning. (authors)

  10. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2012-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  11. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2011-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  12. The Restrictions to the Improper Use of Liability Company's Administration as a Way of Shareholder's Protection

    Directory of Open Access Journals (Sweden)

    João Luis Nogueira Matias

    2016-12-01

    Full Text Available The brazilian limited company, in line with the principles of the Constitution, is not treated as partners's subject. There is the recognition of outside's interest. New standards are set in the internal relations with the protection of the rights of the minority. The partners can shape the limited company governance, however, the brazilian civil code put cogent norms that limit the abuse of management. In this paper will be analyzed the administration typology; agency conflicts; conflicts of interests between direction and the limited company and the management control. It is verified that the restrictions on brazilian limited company administration provides protection to shareholders.

  13. Network Coding to Enhance Standard Routing Protocols in Wireless Mesh Networks

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Roetter, Daniel Enrique Lucani; Fitzek, Frank

    2013-01-01

    This paper introduces a design and simulation of a locally optimized network coding protocol, called PlayNCool, for wireless mesh networks. PlayN-Cool is easy to implement and compatible with existing routing protocols and devices. This allows the system to gain from network coding capabilities i...

  14. [Code of ethics for nurses and territory hospital group].

    Science.gov (United States)

    Danan, Jane-Laure; Giraud-Rochon, François

    2017-09-01

    The publication of the decree relating to the code of ethics for nurses means that the State is producing a text for all nursing professionals, whatever their sector or their mode of practice. However, faced with the standardisation of nursing procedures, the production of a new standard by a government is not a neutral issue. On the one hand, it could constitute a reinforcement of the professional credibility of this corporation; on the other this text becomes enforceable on all nurses and employers. Within a territory hospital group, this reflection must form part of nursing and managerial practices and the relationships with the hospital administration. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Russian Model Of The Administrative Justice

    Directory of Open Access Journals (Sweden)

    Natalja I. Jaroshenko

    2014-12-01

    Full Text Available On December 25, 2014 it would be twenty-one year since the Constitution of the Russian Federation was adopted on the national referendum on December 12, 1993. During this time, almost all constitutional provisions are implemented. The key point of course was the judicial reform in Russia, launched simultaneously with the adoption of Constitution of the Russian Federation. Adopted the new Civil Procedural Code, Criminal Procedural Code, Arbitration Procedural Code of the Russian Federation, Federal Constitutional Law "On the Constitutional Court of the Russian Federation", Federal Constitutional Law "On the courts of general jurisdiction in Russia", Federal Constitutional Law "On the Supreme Court of the Russian Federation". However, during twenty-one year of Russian Constitution work, the question on establishment of administrative courts in our country has not been resolved. Merger of the Supreme Court and the Supreme Arbitration Court of the Russian Federation, which happened in the year 2014, also shown the need to resolve the status of administrative courts in Russia. Previously submitted to the State Duma of the Federal Assembly of the Russian Federation the draft of the Federal Constitutional Law "On the Federal Administrative Courts in the Russian Federation" and is on the revision, which does not correspond to changes in the judicial system of the Russian Federation. Despite the failure of the Federal Constitutional Law "On the Federal Administrative Courts in the Russian Federation", in the opinion of the author, and it should be called that way, it Russia has already developed an own model of the Russian administrative justice, which is very specific.

  16. GENERIC QUALITY STANDARDS VS. SPECIFIC QUALITY STANDARDS: THE CASE OF HIGHER EDUCATION

    Directory of Open Access Journals (Sweden)

    Laila El Abbadi

    2011-06-01

    Full Text Available Quality as a new requirement for the field of higher education leads institutions to seek to satisfy generic or specific quality standards imposed directly or indirectly by its customers. The aim of this study is to compare between ISO9001, as a generic quality standard, and the Code of Practice of the Quality Assurance Agency for Higher Education (QAA, as a specific quality standard. A correlation matrix is drawn and correlation rates are calculated to show similarities and differences between them. This paper shows, first, that ISO9001 and QAA Code of Practice are compatible. Second, implementing a quality management system in accordance with ISO9001 requirements can constitute an adequate framework for the application of the QAA Code of Practice requirements. Third, to make the ISO9001 requirements closer to a specific quality standard in the field of higher education, it is recommended to complete these standards by specific requirements to the field of higher education.

  17. Lossless Coding Standards for Space Data Systems

    Science.gov (United States)

    Rice, R. F.

    1996-01-01

    The International Consultative Committee for Space Data Systems (CCSDS) is preparing to issue its first recommendation for a digital data compression standard. Because the space data systems of primary interest are employed to support scientific investigations requiring accurate representation, this initial standard will be restricted to lossless compression.

  18. A proposal for a code of ethics for nurse practitioners.

    Science.gov (United States)

    Peterson, Moya; Potter, Robert Lyman

    2004-03-01

    To review established codes for health care professionals and standards of practice for the nurse practitioner (NP) and to utilize these codes and standards, general ethical themes, and a new ethical triangle to propose an ethical code for NPs. Reviews of three generally accepted ethical themes (deontological, teleological, and areteological), the ethical triangle by Potter, the American Academy of Nurse Practitioners (AANP) standards of practice for NPs, and codes of ethics from the American Nurses Association (ANA) and the American Medical Association (AMA). A proposal for a code of ethics for NPs is presented. This code was determined by basic ethical themes and established codes for nursing, formulated by the ANA, and for physicians, formulated by the AMA. The proposal was also developed in consideration of the AANP standards of practice for NPs. The role of the NP is unique in its ethical demands. The authors believe that the expanded practice of NPs presents ethical concerns that are not addressed by the ANA code and yet are relevant to nursing and therefore different than the ethical concerns of physicians. This proposal attempts to broaden NPs' perspective of the role that ethics should hold in their professional lives.

  19. Coding-Spreading Tradeoff in CDMA Systems

    National Research Council Canada - National Science Library

    Bolas, Eduardo

    2002-01-01

    .... Comparing different combinations of coding and spreading with a traditional DS-CDMA, as defined in the IS-95 standard, allows the criteria to be defined for the best coding-spreading tradeoff in CDMA systems...

  20. [Quality management and strategic consequences of assessing documentation and coding under the German Diagnostic Related Groups system].

    Science.gov (United States)

    Schnabel, M; Mann, D; Efe, T; Schrappe, M; V Garrel, T; Gotzen, L; Schaeg, M

    2004-10-01

    The introduction of the German Diagnostic Related Groups (D-DRG) system requires redesigning administrative patient management strategies. Wrong coding leads to inaccurate grouping and endangers the reimbursement of treatment costs. This situation emphasizes the roles of documentation and coding as factors of economical success. The aims of this study were to assess the quantity and quality of initial documentation and coding (ICD-10 and OPS-301) and find operative strategies to improve efficiency and strategic means to ensure optimal documentation and coding quality. In a prospective study, documentation and coding quality were evaluated in a standardized way by weekly assessment. Clinical data from 1385 inpatients were processed for initial correctness and quality of documentation and coding. Principal diagnoses were found to be accurate in 82.7% of cases, inexact in 7.1%, and wrong in 10.1%. Effects on financial returns occurred in 16%. Based on these findings, an optimized, interdisciplinary, and multiprofessional workflow on medical documentation, coding, and data control was developed. Workflow incorporating regular assessment of documentation and coding quality is required by the DRG system to ensure efficient accounting of hospital services. Interdisciplinary and multiprofessional cooperation is recognized to be an important factor in establishing an efficient workflow in medical documentation and coding.

  1. Uplink Coding

    Science.gov (United States)

    Andrews, Ken; Divsalar, Dariush; Dolinar, Sam; Moision, Bruce; Hamkins, Jon; Pollara, Fabrizio

    2007-01-01

    This slide presentation reviews the objectives, meeting goals and overall NASA goals for the NASA Data Standards Working Group. The presentation includes information on the technical progress surrounding the objective, short LDPC codes, and the general results on the Pu-Pw tradeoff.

  2. Oil and gas field code master list, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-16

    This document contains data collected through October 1993 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service.

  3. Beyond crosswalks: reliability of exposure assessment following automated coding of free-text job descriptions for occupational epidemiology.

    Science.gov (United States)

    Burstyn, Igor; Slutsky, Anton; Lee, Derrick G; Singer, Alison B; An, Yuan; Michael, Yvonne L

    2014-05-01

    Epidemiologists typically collect narrative descriptions of occupational histories because these are less prone than self-reported exposures to recall bias of exposure to a specific hazard. However, the task of coding these narratives can be daunting and prohibitively time-consuming in some settings. The aim of this manuscript is to evaluate the performance of a computer algorithm to translate the narrative description of occupational codes into standard classification of jobs (2010 Standard Occupational Classification) in an epidemiological context. The fundamental question we address is whether exposure assignment resulting from manual (presumed gold standard) coding of the narratives is materially different from that arising from the application of automated coding. We pursued our work through three motivating examples: assessment of physical demands in Women's Health Initiative observational study, evaluation of predictors of exposure to coal tar pitch volatiles in the US Occupational Safety and Health Administration's (OSHA) Integrated Management Information System, and assessment of exposure to agents known to cause occupational asthma in a pregnancy cohort. In these diverse settings, we demonstrate that automated coding of occupations results in assignment of exposures that are in reasonable agreement with results that can be obtained through manual coding. The correlation between physical demand scores based on manual and automated job classification schemes was reasonable (r = 0.5). The agreement between predictive probability of exceeding the OSHA's permissible exposure level for polycyclic aromatic hydrocarbons, using coal tar pitch volatiles as a surrogate, based on manual and automated coding of jobs was modest (Kendall rank correlation = 0.29). In the case of binary assignment of exposure to asthmagens, we observed that fair to excellent agreement in classifications can be reached, depending on presence of ambiguity in assigned job classification (κ

  4. Protograph-Based Raptor-Like Codes

    Science.gov (United States)

    Divsalar, Dariush; Chen, Tsung-Yi; Wang, Jiadong; Wesel, Richard D.

    2014-01-01

    Theoretical analysis has long indicated that feedback improves the error exponent but not the capacity of pointto- point memoryless channels. The analytic and empirical results indicate that at short blocklength regime, practical rate-compatible punctured convolutional (RCPC) codes achieve low latency with the use of noiseless feedback. In 3GPP, standard rate-compatible turbo codes (RCPT) did not outperform the convolutional codes in the short blocklength regime. The reason is the convolutional codes for low number of states can be decoded optimally using Viterbi decoder. Despite excellent performance of convolutional codes at very short blocklengths, the strength of convolutional codes does not scale with the blocklength for a fixed number of states in its trellis.

  5. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F1--F8 -- Volume 2, Part 1, Revision 4

    Energy Technology Data Exchange (ETDEWEB)

    Greene, N.M.; Petrie, L.M.; Westfall, R.M.; Bucholz, J.A.; Hermann, O.W.; Fraley, S.K. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries.

  6. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F1--F8 -- Volume 2, Part 1, Revision 4

    International Nuclear Information System (INIS)

    Greene, N.M.; Petrie, L.M.; Westfall, R.M.; Bucholz, J.A.; Hermann, O.W.; Fraley, S.K.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries

  7. Evolutionary implications of genetic code deviations

    International Nuclear Information System (INIS)

    Chela Flores, J.

    1986-07-01

    By extending the standard genetic code into a temperature dependent regime, we propose a train of molecular events leading to alternative coding. The first few examples of these deviations have already been reported in some ciliated protozoans and Gram positive bacteria. A possible range of further alternative coding, still within the context of universality, is pointed out. (author)

  8. Building Codes and Regulations.

    Science.gov (United States)

    Fisher, John L.

    The hazard of fire is of great concern to libraries due to combustible books and new plastics used in construction and interiors. Building codes and standards can offer architects and planners guidelines to follow but these standards should be closely monitored, updated, and researched for fire prevention. (DS)

  9. Australasian code for reporting of mineral resources and ore reserves (the JORC code)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-06-01

    The latest revision of the Code first published in 1989 becomes effective in September 1999. It was prepared by the Joint Ores Reserves Committee of the Australasian Institute of Mining and Metallurgy, Australian Institute of Geoscientists and Minerals Council of Australia (JORC). It sets out minimum standards, recommendations and guidelines for public reporting of exploration results, mineral resources and ore reserves in Australasia. In this edition, the guidelines, which were previously separated from the Code, have been placed after the respective Code clauses. The Code is applicable to all solid minerals, including diamonds, other gemstones and coal for which public reporting is required by the Australian and New Zealand Stock Exchanges.

  10. On locality of Generalized Reed-Muller codes over the broadcast erasure channel

    KAUST Repository

    Alloum, Amira

    2016-07-28

    One to Many communications are expected to be among the killer applications for the currently discussed 5G standard. The usage of coding mechanisms is impacting broadcasting standard quality, as coding is involved at several levels of the stack, and more specifically at the application layer where Rateless, LDPC, Reed Slomon codes and network coding schemes have been extensively studied, optimized and standardized in the past. Beyond reusing, extending or adapting existing application layer packet coding mechanisms based on previous schemes and designed for the foregoing LTE or other broadcasting standards; our purpose is to investigate the use of Generalized Reed Muller codes and the value of their locality property in their progressive decoding for Broadcast/Multicast communication schemes with real time video delivery. Our results are meant to bring insight into the use of locally decodable codes in Broadcasting. © 2016 IEEE.

  11. Recent activities in accelerator code development

    International Nuclear Information System (INIS)

    Copper, R.K.; Ryne, R.D.

    1992-01-01

    In this paper we will review recent activities in the area of code development as it affects the accelerator community. We will first discuss the changing computing environment. We will review how the computing environment has changed in the last 10 years, with emphasis on computing power, operating systems, computer languages, graphics standards, and massively parallel processing. Then we will discuss recent code development activities in the areas of electromagnetics codes and beam dynamics codes

  12. Comparison study of judged clinical skills competence from standard setting ratings generated under different administration conditions.

    Science.gov (United States)

    Roberts, William L; Boulet, John; Sandella, Jeanne

    2017-12-01

    When the safety of the public is at stake, it is particularly relevant for licensing and credentialing exam agencies to use defensible standard setting methods to categorize candidates into competence categories (e.g., pass/fail). The aim of this study was to gather evidence to support change to the Comprehensive Osteopathic Medical Licensing-USA Level 2-Performance Evaluation standard setting design and administrative process. Twenty-two video recordings of candidates assessed for clinical competence were randomly selected from the 2014-2015 Humanistic domain test score distribution ranging from the highest to lowest quintile of performance. Nineteen panelists convened at the same site to receive training and practice prior to generating judgments of qualified or not qualified performance to each of the twenty videos. At the end of training, one panel remained onsite to complete their judgments and the second panel was released and given 1 week to observe the same twenty videos and complete their judgments offsite. The two one-sided test procedure established equivalence between panel group means at the 0.05 confidence level, controlling for rater errors within each panel group. From a practical cost-effective and administrative resource perspective, results from this study suggest it is possible to diverge from typical panel groups, who are sequestered the entire time onsite, to larger numbers of panelists who can make their judgments offsite with little impact on judged samples of qualified performance. Standard setting designs having panelists train together and then allowing those to provide judgments yields equivalent ratings and, ultimately, similar cut scores.

  13. Code of practice for ionizing radiation

    International Nuclear Information System (INIS)

    Khoo Boo Huat

    1995-01-01

    Prior to 1984, the use of ionizing radiation in Malaysia was governed by the Radioactive Substances Act of 1968. After 1984, its use came under the control of Act 304, called the Atomic Energy Licensing Act 1984. Under powers vested by the Act, the Radiation Protection (Basic Safety Standards) Regulations 1988 were formulated to regulate its use. These Acts do not provide information on proper working procedures. With the publication of the codes of Practice by The Standards and Industrial Research Institute of Malaysia (SIRIM), the users are now able to follow proper guidelines and use ionizing radiation safely and beneficially. This paper discusses the relevant sections in the following codes: 1. Code of Practice for Radiation Protection (Medical X-ray Diagnosis) MS 838:1983. 2. Code of Practice for Safety in Laboratories Part 4: Ionizing radiation MS 1042: Part 4: 1992. (author)

  14. Code of Federal Regulations in XML

    Data.gov (United States)

    National Archives and Records Administration — The Code of Federal Regulations (CFR) is the codification of the general and permanent rules published in the Federal Register by the executive departments and...

  15. Improving system modeling accuracy with Monte Carlo codes

    International Nuclear Information System (INIS)

    Johnson, A.S.

    1996-01-01

    The use of computer codes based on Monte Carlo methods to perform criticality calculations has become common-place. Although results frequently published in the literature report calculated k eff values to four decimal places, people who use the codes in their everyday work say that they only believe the first two decimal places of any result. The lack of confidence in the computed k eff values may be due to the tendency of the reported standard deviation to underestimate errors associated with the Monte Carlo process. The standard deviation as reported by the codes is the standard deviation of the mean of the k eff values for individual generations in the computer simulation, not the standard deviation of the computed k eff value compared with the physical system. A more subtle problem with the standard deviation of the mean as reported by the codes is that all the k eff values from the separate generations are not statistically independent since the k eff of a given generation is a function of k eff of the previous generation, which is ultimately based on the starting source. To produce a standard deviation that is more representative of the physical system, statistically independent values of k eff are needed

  16. Ethical Leadership Behaviours of School Administrators from Teachers’ Point of View

    Directory of Open Access Journals (Sweden)

    Mukadder Boydak Özan

    2017-06-01

    Full Text Available The main objective of this study is to determine the degree of ethical leadership behaviours of school administrators according to teachers’ opinions. As a quantitative research, this study was carried out in the academic year of 2010-2011 with 371 teachers who were employed in elementary schools. Ethical Leadership Questionnaire developed by Langlois (2007 has been used in the research. Findings of study reveal that as the year of seniority increases, more teachers think that administrators act within the ethical standards. Teachers’ opinions about school administrators’ ethical leadership behaviours do not differentiate according to the teachers’ gender variable. However; in terms of branch variable, a significant difference is observed in teachers’ opinions about their school administrators’ ethical leadership behaviours when they faced with an ethical problem. Class teachers’ opinions are more positive than branch teachers’ opinions regarding school administrators’ ethical leadership behaviours. Results indicate that teachers think that their school administrators often faced with an ethical dilemma while deciding upon personnel issues. This study concludes that establishing written ethical codes for school administrators may help them to make decisions with integrity, fairness, and in a more ethical manner especially about personnel issues.

  17. MISTRA facility for containment lumped parameter and CFD codes validation. Example of the International Standard Problem ISP47

    International Nuclear Information System (INIS)

    Tkatschenko, I.; Studer, E.; Paillere, H.

    2005-01-01

    During a severe accident in a Pressurized Water Reactor (PWR), the formation of a combustible gas mixture in the complex geometry of the reactor depends on the understanding of hydrogen production, the complex 3D thermal-hydraulics flow due to gas/steam injection, natural convection, heat transfer by condensation on walls and effect of mitigation devices. Numerical simulation of such flows may be performed either by Lumped Parameter (LP) or by Computational Fluid Dynamics (CFD) codes. Advantages and drawbacks of LP and CFD codes are well-known. LP codes are mainly developed for full size containment analysis but they need improvements, especially since they are not able to accurately predict the local gas mixing within the containment. CFD codes require a process of validation on well-instrumented experimental data before they can be used with a high degree of confidence. The MISTRA coupled effect test facility has been built at CEA to fulfil this validation objective: with numerous measurement points in the gaseous volume - temperature, gas concentration, velocity and turbulence - and with well controlled boundary conditions. As illustration of both experimental and simulation areas of this topic, a recent example in the use of MISTRA test data is presented for the case of the International Standard Problem ISP47. The proposed experimental work in the MISTRA facility provides essential data to fill the gaps in the modelling/validation of computational tools. (author)

  18. Improved lossless intra coding for H.264/MPEG-4 AVC.

    Science.gov (United States)

    Lee, Yung-Lyul; Han, Ki-Hun; Sullivan, Gary J

    2006-09-01

    A new lossless intra coding method based on sample-by-sample differential pulse code modulation (DPCM) is presented as an enhancement of the H.264/MPEG-4 AVC standard. The H.264/AVC design includes a multidirectional spatial prediction method to reduce spatial redundancy by using neighboring samples as a prediction for the samples in a block of data to be encoded. In the new lossless intra coding method, the spatial prediction is performed based on samplewise DPCM instead of in the block-based manner used in the current H.264/AVC standard, while the block structure is retained for the residual difference entropy coding process. We show that the new method, based on samplewise DPCM, does not have a major complexity penalty, despite its apparent pipeline dependencies. Experiments show that the new lossless intra coding method reduces the bit rate by approximately 12% in comparison with the lossless intra coding method previously included in the H.264/AVC standard. As a result, the new method is currently being adopted into the H.264/AVC standard in a new enhancement project.

  19. MEMOPS: data modelling and automatic code generation.

    Science.gov (United States)

    Fogh, Rasmus H; Boucher, Wayne; Ionides, John M C; Vranken, Wim F; Stevens, Tim J; Laue, Ernest D

    2010-03-25

    In recent years the amount of biological data has exploded to the point where much useful information can only be extracted by complex computational analyses. Such analyses are greatly facilitated by metadata standards, both in terms of the ability to compare data originating from different sources, and in terms of exchanging data in standard forms, e.g. when running processes on a distributed computing infrastructure. However, standards thrive on stability whereas science tends to constantly move, with new methods being developed and old ones modified. Therefore maintaining both metadata standards, and all the code that is required to make them useful, is a non-trivial problem. Memops is a framework that uses an abstract definition of the metadata (described in UML) to generate internal data structures and subroutine libraries for data access (application programming interfaces--APIs--currently in Python, C and Java) and data storage (in XML files or databases). For the individual project these libraries obviate the need for writing code for input parsing, validity checking or output. Memops also ensures that the code is always internally consistent, massively reducing the need for code reorganisation. Across a scientific domain a Memops-supported data model makes it easier to support complex standards that can capture all the data produced in a scientific area, share them among all programs in a complex software pipeline, and carry them forward to deposition in an archive. The principles behind the Memops generation code will be presented, along with example applications in Nuclear Magnetic Resonance (NMR) spectroscopy and structural biology.

  20. OECD International Standard Problem number 34. Falcon code comparison report

    International Nuclear Information System (INIS)

    Williams, D.A.

    1994-12-01

    ISP-34 is the first ISP to address fission product transport issues and has been strongly supported by a large number of different countries and organisations. The ISP is based on two experiments, FAL-ISP-1 and FAL-ISP-2, which were conducted in AEA's Falcon facility. Specific features of the experiments include quantification of chemical effects and aerosol behaviour. In particular, multi-component aerosol effects and vapour-aerosol interactions can all be investigated in the Falcon facility. Important parameters for participants to predict were the deposition profiles and composition, key chemical species and reactions, evolution of suspended material concentrations, and the effects of steam condensation onto aerosols and particle hygroscopicity. The results of the Falcon ISP support the belief that aerosol physics is generally well modelled in primary circuit codes, but the chemistry models in many of the codes need to be improved, since chemical speciation is one of the main factors which controls transport and deposition behaviour. The importance of chemical speciation, aerosol nucleation, and the role of multi-component aerosols in determining transport and deposition behaviour are evident. The role of re-vaporization in these Falcon experiments is not clear; it is not possible to compare those codes which predicted re-vaporization with quantitative data. The evidence from this ISP exercise indicates that the containment codes can predict thermal-hydraulics conditions satisfactorily. However, the differences in the predicted aerosol locations in the Falcon tests had shown that aerosol behaviour was very susceptible to parameters such as particle size distribution

  1. Code portability and data management considerations in the SAS3D LMFBR accident-analysis code

    International Nuclear Information System (INIS)

    Dunn, F.E.

    1981-01-01

    The SAS3D code was produced from a predecessor in order to reduce or eliminate interrelated problems in the areas of code portability, the large size of the code, inflexibility in the use of memory and the size of cases that can be run, code maintenance, and running speed. Many conventional solutions, such as variable dimensioning, disk storage, virtual memory, and existing code-maintenance utilities were not feasible or did not help in this case. A new data management scheme was developed, coding standards and procedures were adopted, special machine-dependent routines were written, and a portable source code processing code was written. The resulting code is quite portable, quite flexible in the use of memory and the size of cases that can be run, much easier to maintain, and faster running. SAS3D is still a large, long running code that only runs well if sufficient main memory is available

  2. Validity of peptic ulcer disease and upper gastrointestinal bleeding diagnoses in administrative databases: a systematic review protocol.

    Science.gov (United States)

    Montedori, Alessandro; Abraha, Iosief; Chiatti, Carlos; Cozzolino, Francesco; Orso, Massimiliano; Luchetta, Maria Laura; Rimland, Joseph M; Ambrosio, Giuseppe

    2016-09-15

    Administrative healthcare databases are useful to investigate the epidemiology, health outcomes, quality indicators and healthcare utilisation concerning peptic ulcers and gastrointestinal bleeding, but the databases need to be validated in order to be a reliable source for research. The aim of this protocol is to perform the first systematic review of studies reporting the validation of International Classification of Diseases, 9th Revision and 10th version (ICD-9 and ICD-10) codes for peptic ulcer and upper gastrointestinal bleeding diagnoses. MEDLINE, EMBASE, Web of Science and the Cochrane Library databases will be searched, using appropriate search strategies. We will include validation studies that used administrative data to identify peptic ulcer disease and upper gastrointestinal bleeding diagnoses or studies that evaluated the validity of peptic ulcer and upper gastrointestinal bleeding codes in administrative data. The following inclusion criteria will be used: (a) the presence of a reference standard case definition for the diseases of interest; (b) the presence of at least one test measure (eg, sensitivity, etc) and (c) the use of an administrative database as a source of data. Pairs of reviewers will independently abstract data using standardised forms and will evaluate quality using the checklist of the Standards for Reporting of Diagnostic Accuracy (STARD) criteria. This systematic review protocol has been produced in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol (PRISMA-P) 2015 statement. Ethics approval is not required given that this is a protocol for a systematic review. We will submit results of this study to a peer-reviewed journal for publication. The results will serve as a guide for researchers validating administrative healthcare databases to determine appropriate case definitions for peptic ulcer disease and upper gastrointestinal bleeding, as well as to perform outcome research using

  3. Dynamic code block size for JPEG 2000

    Science.gov (United States)

    Tsai, Ping-Sing; LeCornec, Yann

    2008-02-01

    Since the standardization of the JPEG 2000, it has found its way into many different applications such as DICOM (digital imaging and communication in medicine), satellite photography, military surveillance, digital cinema initiative, professional video cameras, and so on. The unified framework of the JPEG 2000 architecture makes practical high quality real-time compression possible even in video mode, i.e. motion JPEG 2000. In this paper, we present a study of the compression impact using dynamic code block size instead of fixed code block size as specified in the JPEG 2000 standard. The simulation results show that there is no significant impact on compression if dynamic code block sizes are used. In this study, we also unveil the advantages of using dynamic code block sizes.

  4. Physician involvement enhances coding accuracy to ensure national standards: an initiative to improve awareness among new junior trainees.

    Science.gov (United States)

    Nallasivan, S; Gillott, T; Kamath, S; Blow, L; Goddard, V

    2011-06-01

    Record Keeping Standards is a development led by the Royal College of Physicians of London (RCP) Health Informatics Unit and funded by the National Health Service (NHS) Connecting for Health. A supplementary report produced by the RCP makes a number of recommendations based on a study held at an acute hospital trust. We audited the medical notes and coding to assess the accuracy, documentation by the junior doctors and also to correlate our findings with the RCP audit. Northern Lincolnshire & Goole Hospitals NHS Foundation Trust has 114,000 'finished consultant episodes' per year. A total of 100 consecutive medical (50) and rheumatology (50) discharges from Diana Princess of Wales Hospital from August-October 2009 were reviewed. The results showed an improvement in coding accuracy (10% errors), comparable to the RCP audit but with 5% documentation errors. Physician involvement needs enhancing to improve the effectiveness and to ensure clinical safety.

  5. LUCID - an optical design and raytrace code

    International Nuclear Information System (INIS)

    Nicholas, D.J.; Duffey, K.P.

    1980-11-01

    A 2D optical design and ray trace code is described. The code can operate either as a geometric optics propagation code or provide a scalar diffraction treatment. There are numerous non-standard options within the code including design and systems optimisation procedures. A number of illustrative problems relating to the design of optical components in the field of high power lasers is included. (author)

  6. 7 CFR 800.2 - Administrator.

    Science.gov (United States)

    2010-01-01

    ... which would not impair the objectives of the Act, suspend for period determined by the Administrator any... ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Administration... administration of the United States Grain Standards Act and responsibilities under the Agricultural Marketing Act...

  7. Semi-Automated Annotation of Biobank Data Using Standard Medical Terminologies in a Graph Database.

    Science.gov (United States)

    Hofer, Philipp; Neururer, Sabrina; Goebel, Georg

    2016-01-01

    Data describing biobank resources frequently contains unstructured free-text information or insufficient coding standards. (Bio-) medical ontologies like Orphanet Rare Diseases Ontology (ORDO) or the Human Disease Ontology (DOID) provide a high number of concepts, synonyms and entity relationship properties. Such standard terminologies increase quality and granularity of input data by adding comprehensive semantic background knowledge from validated entity relationships. Moreover, cross-references between terminology concepts facilitate data integration across databases using different coding standards. In order to encourage the use of standard terminologies, our aim is to identify and link relevant concepts with free-text diagnosis inputs within a biobank registry. Relevant concepts are selected automatically by lexical matching and SPARQL queries against a RDF triplestore. To ensure correctness of annotations, proposed concepts have to be confirmed by medical data administration experts before they are entered into the registry database. Relevant (bio-) medical terminologies describing diseases and phenotypes were identified and stored in a graph database which was tied to a local biobank registry. Concept recommendations during data input trigger a structured description of medical data and facilitate data linkage between heterogeneous systems.

  8. The Development of the World Anti-Doping Code.

    Science.gov (United States)

    Young, Richard

    2017-01-01

    This chapter addresses both the development and substance of the World Anti-Doping Code, which came into effect in 2003, as well as the subsequent Code amendments, which came into effect in 2009 and 2015. Through an extensive process of stakeholder input and collaboration, the World Anti-Doping Code has transformed the hodgepodge of inconsistent and competing pre-2003 anti-doping rules into a harmonized and effective approach to anti-doping. The Code, as amended, is now widely recognized worldwide as the gold standard in anti-doping. The World Anti-Doping Code originally went into effect on January 1, 2004. The first amendments to the Code went into effect on January 1, 2009, and the second amendments on January 1, 2015. The Code and the related international standards are the product of a long and collaborative process designed to make the fight against doping more effective through the adoption and implementation of worldwide harmonized rules and best practices. © 2017 S. Karger AG, Basel.

  9. 34 CFR 74.42 - Codes of conduct.

    Science.gov (United States)

    2010-07-01

    ... Procurement Standards § 74.42 Codes of conduct. The recipient shall maintain written standards of conduct... interest is not substantial or the gift is an unsolicited item of nominal value. The standards of conduct...

  10. 22 CFR 518.42 - Codes of conduct.

    Science.gov (United States)

    2010-04-01

    ... Procurement Standards § 518.42 Codes of conduct. The recipient shall maintain written standards of conduct... financial interest is not substantial or the gift is an unsolicited item of nominal value. The standards of...

  11. Some optimizations of the animal code

    International Nuclear Information System (INIS)

    Fletcher, W.T.

    1975-01-01

    Optimizing techniques were performed on a version of the ANIMAL code (MALAD1B) at the source-code (FORTRAN) level. Sample optimizing techniques and operations used in MALADOP--the optimized version of the code--are presented, along with a critique of some standard CDC 7600 optimizing techniques. The statistical analysis of total CPU time required for MALADOP and MALAD1B shows a run-time saving of 174 msec (almost 3 percent) in the code MALADOP during one time step

  12. Telemetry advances in data compression and channel coding

    Science.gov (United States)

    Miller, Warner H.; Morakis, James C.; Yeh, Pen-Shu

    1990-01-01

    Addressed in this paper is the dependence of telecommunication channel, forward error correcting coding and source data compression coding on integrated circuit technology. Emphasis is placed on real time high speed Reed Solomon (RS) decoding using full custom VLSI technology. Performance curves of NASA's standard channel coder and a proposed standard lossless data compression coder are presented.

  13. 7 CFR 30.61 - Administration.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Administration. 30.61 Section 30.61 Agriculture... AND STANDARDS Administration § 30.61 Administration. The Director, Tobacco Division, Agricultural... the Division and the performance of all duties assigned thereto in the administration of the Tobacco...

  14. Minor Theft: Problems of the Initiation of a Case on an Administrative Offense and Conducting an Administrative Investigation

    Directory of Open Access Journals (Sweden)

    Oleg Y. Filippov

    2016-11-01

    Full Text Available The paper defines the problem of the initiation of an administrative case and conducting an administrative investigation on cases of identifying signs of minor theft under Art. 7.27 of the Code of Administrative Offences of the Russian Federation in cases where the identity of the offender at the time of committing minor theft is not established, this person is not detained. Guidance on the application of this provision under the existing legislation and on amendments and supplements to the law on administrative offenses is offered.

  15. Administrative Algorithms to identify Avascular necrosis of bone among patients undergoing upper or lower extremity magnetic resonance imaging: a validation study.

    Science.gov (United States)

    Barbhaiya, Medha; Dong, Yan; Sparks, Jeffrey A; Losina, Elena; Costenbader, Karen H; Katz, Jeffrey N

    2017-06-19

    Studies of the epidemiology and outcomes of avascular necrosis (AVN) require accurate case-finding methods. The aim of this study was to evaluate performance characteristics of a claims-based algorithm designed to identify AVN cases in administrative data. Using a centralized patient registry from a US academic medical center, we identified all adults aged ≥18 years who underwent magnetic resonance imaging (MRI) of an upper/lower extremity joint during the 1.5 year study period. A radiologist report confirming AVN on MRI served as the gold standard. We examined the sensitivity, specificity, positive predictive value (PPV) and positive likelihood ratio (LR + ) of four algorithms (A-D) using International Classification of Diseases, 9th edition (ICD-9) codes for AVN. The algorithms ranged from least stringent (Algorithm A, requiring ≥1 ICD-9 code for AVN [733.4X]) to most stringent (Algorithm D, requiring ≥3 ICD-9 codes, each at least 30 days apart). Among 8200 patients who underwent MRI, 83 (1.0% [95% CI 0.78-1.22]) had AVN by gold standard. Algorithm A yielded the highest sensitivity (81.9%, 95% CI 72.0-89.5), with PPV of 66.0% (95% CI 56.0-75.1). The PPV of algorithm D increased to 82.2% (95% CI 67.9-92.0), although sensitivity decreased to 44.6% (95% CI 33.7-55.9). All four algorithms had specificities >99%. An algorithm that uses a single billing code to screen for AVN among those who had MRI has the highest sensitivity and is best suited for studies in which further medical record review confirming AVN is feasible. Algorithms using multiple billing codes are recommended for use in administrative databases when further AVN validation is not feasible.

  16. NAICS Sector 92: Public Administration

    Science.gov (United States)

    Find the public administration industries EPA regulations affect, with their North American Industry Classification System (NAICS) code. On those pages you can find a list of laws and regulations that affect your industry as well as compliance information

  17. 24 CFR 92.251 - Property standards.

    Science.gov (United States)

    2010-04-01

    ..., as applicable, one of three model codes: Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI); or the Council of American Building Officials (CABO) one or two...) Housing that is constructed or rehabilitated with HOME funds must meet all applicable local codes...

  18. The Codex standard and code for irradiated foods

    International Nuclear Information System (INIS)

    Erwin, L.

    1985-01-01

    A brief background on the work by the Codex Alimentarius Commission on irradiated foods is given. An Australian model food standard for irradiated foods, based on the Codex standard, is being developed

  19. 17 CFR 275.204A-1 - Investment adviser codes of ethics.

    Science.gov (United States)

    2010-04-01

    ... ethics. 275.204A-1 Section 275.204A-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE... codes of ethics. (a) Adoption of code of ethics. If you are an investment adviser registered or required... enforce a written code of ethics that, at a minimum, includes: (1) A standard (or standards) of business...

  20. VALIDATION OF SIMBAT-PWR USING STANDARD CODE OF COBRA-EN ON REACTOR TRANSIENT CONDITION

    Directory of Open Access Journals (Sweden)

    Muhammad Darwis Isnaini

    2016-03-01

    Full Text Available The validation of Pressurized Water Reactor typed Nuclear Power Plant simulator developed by BATAN (SIMBAT-PWR using standard code of COBRA-EN on reactor transient condition has been done. The development of SIMBAT-PWR has accomplished several neutronics and thermal-hydraulic calculation modules. Therefore, the validation of the simulator is needed, especially in transient reactor operation condition. The research purpose is for characterizing the thermal-hydraulic parameters of PWR1000 core, which be able to be applied or as a comparison in developing the SIMBAT-PWR. The validation involves the calculation of the thermal-hydraulic parameters using COBRA-EN code. Furthermore, the calculation schemes are based on COBRA-EN with fixed material properties and dynamic properties that calculated by MATPRO subroutine (COBRA-EN+MATPRO for reactor condition of startup, power rise and power fluctuation from nominal to over power. The comparison of the temperature distribution at nominal 100% power shows that the fuel centerline temperature calculated by SIMBAT-PWR has 8.76% higher result than COBRA-EN result and 7.70% lower result than COBRA-EN+MATPRO. In general, SIMBAT-PWR calculation results on fuel temperature distribution are mostly between COBRA-EN and COBRA-EN+MATPRO results. The deviations of the fuel centerline, fuel surface, inner and outer cladding as well as coolant bulk temperature in the SIMBAT-PWR and the COBRA-EN calculation, are due to the value difference of the gap heat transfer coefficient and the cladding thermal conductivity.

  1. 78 FR 78717 - Reservoirs at Headwaters of the Mississippi River; Use and Administration

    Science.gov (United States)

    2013-12-27

    ... Headwaters of the Mississippi River; Use and Administration AGENCY: U.S. Army Corps of Engineers, DoD. ACTION... administration of the reservoirs at the headwaters of the Mississippi River by deleting from the Code of Federal... values that differ from those currently codified in the Code of Federal Regulations. Deleting all...

  2. The H.264/MPEG4 advanced video coding

    Science.gov (United States)

    Gromek, Artur

    2009-06-01

    H.264/MPEG4-AVC is the newest video coding standard recommended by International Telecommunication Union - Telecommunication Standardization Section (ITU-T) and the ISO/IEC Moving Picture Expert Group (MPEG). The H.264/MPEG4-AVC has recently become leading standard for generic audiovisual services, since deployment for digital television. Nowadays is commonly used in wide range of video application ranging like mobile services, videoconferencing, IPTV, HDTV, video storage and many more. In this article, author briefly describes the technology applied in the H.264/MPEG4-AVC video coding standard, the way of real-time implementation and the way of future development.

  3. 5 CFR 179.307 - Administrative offset.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Administrative offset. 179.307 Section 179.307 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.307 Administrative offset. (a) If the debtor does not...

  4. 25 CFR 11.705 - Removal of executor or administrator.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Removal of executor or administrator. 11.705 Section 11... OFFENSES AND LAW AND ORDER CODE Probate Proceedings § 11.705 Removal of executor or administrator. The Court of Indian Offenses may order the executor or administrator to show cause why he or she should not...

  5. The NMC code: conduct, performance and ethics.

    Science.gov (United States)

    Goldsmith, Jan

    The Code: Standards of Conduct, Performance and Ethics for Nurses and Midwives is a set of key principles that should underpin the practice of all nurses and midwives, and remind them of their professional responsibilities. It is not just a tool used in fitness-to-practise cases--it should be used to guide daily practice for all nurses and midwives. Alongside other standards, guidance and advice from the NMC, the code should be used to support professional development.

  6. Code of ethics: principles for ethical leadership.

    Science.gov (United States)

    Flite, Cathy A; Harman, Laurinda B

    2013-01-01

    The code of ethics for a professional association incorporates values, principles, and professional standards. A review and comparative analysis of a 1934 pledge and codes of ethics from 1957, 1977, 1988, 1998, 2004, and 2011 for a health information management association was conducted. Highlights of some changes in the healthcare delivery system are identified as a general context for the codes of ethics. The codes of ethics are examined in terms of professional values and changes in the language used to express the principles of the various codes.

  7. Polar Coding with CRC-Aided List Decoding

    Science.gov (United States)

    2015-08-01

    TECHNICAL REPORT 2087 August 2015 Polar Coding with CRC-Aided List Decoding David Wasserman Approved...list decoding . RESULTS Our simulation results show that polar coding can produce results very similar to the FEC used in the Digital Video...standard. RECOMMENDATIONS In any application for which the DVB-S2 FEC is considered, polar coding with CRC-aided list decod - ing with N = 65536

  8. 45 CFR 74.42 - Codes of conduct.

    Science.gov (United States)

    2010-10-01

    ..., AND COMMERCIAL ORGANIZATIONS Post-Award Requirements Procurement Standards § 74.42 Codes of conduct... the gift is an unsolicited item of nominal value. The standards of conduct shall provide for...

  9. The impact of three discharge coding methods on the accuracy of diagnostic coding and hospital reimbursement for inpatient medical care.

    Science.gov (United States)

    Tsopra, Rosy; Peckham, Daniel; Beirne, Paul; Rodger, Kirsty; Callister, Matthew; White, Helen; Jais, Jean-Philippe; Ghosh, Dipansu; Whitaker, Paul; Clifton, Ian J; Wyatt, Jeremy C

    2018-07-01

    Coding of diagnoses is important for patient care, hospital management and research. However coding accuracy is often poor and may reflect methods of coding. This study investigates the impact of three alternative coding methods on the inaccuracy of diagnosis codes and hospital reimbursement. Comparisons of coding inaccuracy were made between a list of coded diagnoses obtained by a coder using (i)the discharge summary alone, (ii)case notes and discharge summary, and (iii)discharge summary with the addition of medical input. For each method, inaccuracy was determined for the primary, secondary diagnoses, Healthcare Resource Group (HRG) and estimated hospital reimbursement. These data were then compared with a gold standard derived by a consultant and coder. 107 consecutive patient discharges were analysed. Inaccuracy of diagnosis codes was highest when a coder used the discharge summary alone, and decreased significantly when the coder used the case notes (70% vs 58% respectively, p coded from the discharge summary with medical support (70% vs 60% respectively, p coding with case notes, and 35% for coding with medical support. The three coding methods resulted in an annual estimated loss of hospital remuneration of between £1.8 M and £16.5 M. The accuracy of diagnosis codes and percentage of correct HRGs improved when coders used either case notes or medical support in addition to the discharge summary. Further emphasis needs to be placed on improving the standard of information recorded in discharge summaries. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Cement: Administrative tender specifications and standards in Spain

    OpenAIRE

    Soria Santamaría, Francisco

    1991-01-01

    The paper describes, in chronological order, the different competent Authorities in Spain and the documents issued by them regarding Cement Regulations and Standards. The origin of the early cement quality Rules is referred to, the issuing of Regulations by the Public Bodies and finally the adoption of National Standards on the one hand, as well as the first initiatives to establish International Standards, especially motivated by the export boom after the Second World War, on the other. ...

  11. Educational leadership standards preferred by school administrators in educational leadership development [Okul yöneticilerinin eğitim liderliği geliştirmede tercih ettikleri eğitim liderliği standartları

    Directory of Open Access Journals (Sweden)

    Betül BALKAR

    2015-04-01

    Full Text Available The aim of this study is to determine the educational leadership standards considered most important by school administrators in order to develop educational leaders through educational leadership development programs. This study also aims to reveal the development needs of school administrators regarding the educational leadership standards required to be leaders in education. Scaling technique based on rank order judgments was used in order to determine the opinions of school administrators on the importance level of educational leadership standards which can be used to develop educational leaders. The study was performed on 132 school administrators working in the Gaziantep province of Turkey, who were participating in a post-graduate program of Educational Administration Supervision Planning and Economics (EASPE. According to the results, while the most important standard to be involved in educational leadership development programs is the creating of a school culture, the least important standard is administering school resources and processes. Based on the results, it is suggested that educational leadership development programs should be designed in accordance with the needs of school administrators as long-term programs.

  12. Overview of Development and Deployment of Codes, Standards and Regulations Affecting Energy Storage System Safety in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.

    2014-08-22

    This report acquaints stakeholders and interested parties involved in the development and/or deployment of energy storage systems (ESS) with the subject of safety-related codes, standards and regulations (CSRs). It is hoped that users of this document gain a more in depth and uniform understanding of safety-related CSR development and deployment that can foster improved communications among all ESS stakeholders and the collaboration needed to realize more timely acceptance and approval of safe ESS technology through appropriate CSR.

  13. IM (Integrity Management) software must show flexibility to local codes

    Energy Technology Data Exchange (ETDEWEB)

    Brors, Markus [ROSEN Technology and Research Center GmbH (Germany); Diggory, Ian [Macaw Engineering Ltd., Northumberland (United Kingdom)

    2009-07-01

    There are many internationally recognized codes and standards, such as API 1160 and ASME B31.8S, which help pipeline operators to manage and maintain the integrity of their pipeline networks. However, operators in many countries still use local codes that often reflect the history of pipeline developments in their region and are based on direct experience and research on their pipelines. As pipeline companies come under increasing regulatory and financial pressures to maintain the integrity of their networks, it is important that operators using regional codes are able to benchmark their integrity management schemes against these international standards. Any comprehensive Pipeline Integrity Management System (PIMS) software package should therefore not only incorporate industry standards for pipeline integrity assessment but also be capable of implementing regional codes for comparison purposes. This paper describes the challenges and benefits of incorporating one such set of regional pipeline standards into ROSEN Asset Integrity Management Software (ROAIMS). (author)

  14. Continuous Non-malleable Codes

    DEFF Research Database (Denmark)

    Faust, Sebastian; Mukherjee, Pratyay; Nielsen, Jesper Buus

    2014-01-01

    or modify it to the encoding of a completely unrelated value. This paper introduces an extension of the standard non-malleability security notion - so-called continuous non-malleability - where we allow the adversary to tamper continuously with an encoding. This is in contrast to the standard notion of non...... is necessary to achieve continuous non-malleability in the split-state model. Moreover, we illustrate that none of the existing constructions satisfies our uniqueness property and hence is not secure in the continuous setting. We construct a split-state code satisfying continuous non-malleability. Our scheme...... is based on the inner product function, collision-resistant hashing and non-interactive zero-knowledge proofs of knowledge and requires an untamperable common reference string. We apply continuous non-malleable codes to protect arbitrary cryptographic primitives against tampering attacks. Previous...

  15. Cost reducing code implementation strategies

    International Nuclear Information System (INIS)

    Kurtz, Randall L.; Griswold, Michael E.; Jones, Gary C.; Daley, Thomas J.

    1995-01-01

    Sargent and Lundy's Code consulting experience reveals a wide variety of approaches toward implementing the requirements of various nuclear Codes Standards. This paper will describe various Code implementation strategies which assure that Code requirements are fully met in a practical and cost-effective manner. Applications to be discussed includes the following: new construction; repair, replacement and modifications; assessments and life extensions. Lessons learned and illustrative examples will be included. Preferred strategies and specific recommendations will also be addressed. Sargent and Lundy appreciates the opportunity provided by the Korea Atomic Industrial Forum and Korean Nuclear Society to share our ideas and enhance global cooperation through the exchange of information and views on relevant topics

  16. PostgreSQL 9 administration cookbook

    CERN Document Server

    Riggs, Simon; Krosing, Hannu; Bartolini, Gabriele

    2015-01-01

    Through example-driven recipes, with plenty of code, focused on the most vital features of the latest PostgreSQL version (9.4), both administrators and developers will follow short, specific guides to understand and leverage useful Postgre functionalities to create better and more efficient databases.

  17. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F9--F16 -- Volume 2, Part 2, Revision 4

    Energy Technology Data Exchange (ETDEWEB)

    West, J.T.; Hoffman, T.J.; Emmett, M.B.; Childs, K.W.; Petrie, L.M.; Landers, N.F.; Bryan, C.B.; Giles, G.E. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries. This volume discusses the following functional modules: MORSE-SGC; HEATING 7.2; KENO V.a; JUNEBUG-II; HEATPLOT-S; REGPLOT 6; PLORIGEN; and OCULAR.

  18. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F9--F16 -- Volume 2, Part 2, Revision 4

    International Nuclear Information System (INIS)

    West, J.T.; Hoffman, T.J.; Emmett, M.B.; Childs, K.W.; Petrie, L.M.; Landers, N.F.; Bryan, C.B.; Giles, G.E.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries. This volume discusses the following functional modules: MORSE-SGC; HEATING 7.2; KENO V.a; JUNEBUG-II; HEATPLOT-S; REGPLOT 6; PLORIGEN; and OCULAR

  19. 20 CFR 435.42 - Codes of conduct.

    Science.gov (United States)

    2010-04-01

    ... ORGANIZATIONS Post-Award Requirements Procurement Standards § 435.42 Codes of conduct. The recipient must... set standards for situations in which the financial interest is not substantial or the gift is an...

  20. 15 CFR 14.42 - Codes of conduct.

    Science.gov (United States)

    2010-01-01

    ... ORGANIZATIONS Post-Award Requirements Procurement Standards § 14.42 Codes of conduct. The recipient shall... standards for situations in which the financial interest is not substantial or the gift is an unsolicited...

  1. 28 CFR 70.42 - Codes of conduct.

    Science.gov (United States)

    2010-07-01

    ...-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 70.42 Codes of conduct. The..., recipients may set standards for situations in which the financial interest is not substantial or the gift is...

  2. Effective enforcement of the forest practices code

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The British Columbia Forest Practices Code establishes a scheme to guide and direct forest harvesting and other forest uses in concert with other related acts. The Code is made up of the Forest Practices Code of British Columbia Act, regulations, standards, and guidebooks. This document provides information on Code enforcement. It reviews the roles of the three provincial resource ministries and the Attorney General in enforcing the code, the various activities undertaken to ensure compliance (including inspections, investigations, and responses to noncompliance), and the role of the public in helping to enforce the Code. The appendix contains a list of Ministry of Forests office locations and telephone numbers.

  3. Code system BCG for gamma-ray skyshine calculation

    International Nuclear Information System (INIS)

    Ryufuku, Hiroshi; Numakunai, Takao; Miyasaka, Shun-ichi; Minami, Kazuyoshi.

    1979-03-01

    A code system BCG has been developed for calculating conveniently and efficiently gamma-ray skyshine doses using the transport calculation codes ANISN and DOT and the point-kernel calculation codes G-33 and SPAN. To simplify the input forms to the system, the forms for these codes are unified, twelve geometric patterns are introduced to give material regions, and standard data are available as a library. To treat complex arrangements of source and shield, it is further possible to use successively the code such that the results from one code may be used as input data to the same or other code. (author)

  4. Accuracy of clinical coding from 1210 appendicectomies in a British district general hospital.

    Science.gov (United States)

    Bhangu, Aneel; Nepogodiev, Dmitri; Taylor, Caroline; Durkin, Natalie; Patel, Rajan

    2012-01-01

    The primary aim of this study was to assess the accuracy of clinical coding in identifying negative appendicectomies. The secondary aim was to analyse trends over time in rates of simple, complex (gangrenous or perforated) and negative appendicectomies. Retrospective review of 1210 patients undergoing emergency appendicectomy during a five year period (2006-2010). Histopathology reports were taken as gold standard for diagnosis and compared to clinical coding lists. Clinical coding is the process by which non-medical administrators apply standardised diagnostic codes to patients, based upon clinical notes at discharge. These codes then contribute to national databases. Statistical analysis included correlation studies and regression analyses. Clinical coding had only moderate correlation with histopathology, with an overall kappa of 0.421. Annual kappa values varied between 0.378 and 0.500. Overall 14% of patients were incorrectly coded as having had appendicitis when in fact they had a histopathologically normal appendix (153/1107), whereas 4% were falsely coded as having received a negative appendicectomy when they had appendicitis (48/1107). There was an overall significant fall and then rise in the rate of simple appendicitis (B coefficient -0.239 (95% confidence interval -0.426, -0.051), p = 0.014) but no change in the rate of complex appendicitis (B coefficient 0.008 (-0.015, 0.031), p = 0.476). Clinical coding for negative appendicectomy was unreliable. Negative rates may be higher than suspected. This has implications for the validity of national database analyses. Using this form of data as a quality indictor for appendicitis should be reconsidered until its quality is improved. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Monitoring compliance with standards of care for chronic diseases using healthcare administrative databases in Italy: Strengths and limitations.

    Directory of Open Access Journals (Sweden)

    Rosa Gini

    Full Text Available A recent comprehensive report on healthcare quality in Italy published by the Organization of Economic Co-operation and Development (OECD recommended that regular monitoring of quality of primary care by means of compliance with standards of care for chronic diseases is performed. A previous ecological study demonstrated that compliance with standards of care could be reliably estimated on regional level using administrative databases. This study compares estimates based on administrative data with estimates based on GP records for the same persons, to understand whether ecological fallacy played a role in the results of the previous study.We compared estimates of compliance with diagnostic and therapeutic standards of care for type 2 diabetes (T2DM, hypertension and ischaemic heart disease (IHD from administrative data (IAD with estimates from medical records (MR for the same persons registered with 24 GP's in 2012. Data were linked at an individual level.32,688 persons entered the study, 12,673 having at least one of the three diseases according to at least one data source. Patients not detected by IAD were many, for all three conditions: adding MR increased the number of cases of T2DM, hypertension, and IHD by +40%, +42%, and +104%, respectively. IAD had imperfect sensitivity in detecting population compliance with therapies (adding MR increased the estimate, from +11.5% for statins to +14.7% for antithrombotics, and, more substantially, with diagnostic recommendations (adding MR increased the estimate, from +23.7% in glycated hemoglobin tests, to +50.5% in electrocardiogram. Patients not detected by IAD were less compliant with respect to those that IAD correctly identified (from -4.8 percentage points in proportion of IHD patients compliant with a yearly glycated hemoglobin test, to -40.1 points in the proportion of T2DM patients compliant with the same recommendation. IAD overestimated indicators of compliance with therapeutic standards

  6. Validity of International Classification of Diseases (ICD) coding for dengue infections in hospital discharge records in Malaysia.

    Science.gov (United States)

    Woon, Yuan-Liang; Lee, Keng-Yee; Mohd Anuar, Siti Fatimah Zahra; Goh, Pik-Pin; Lim, Teck-Onn

    2018-04-20

    Hospitalization due to dengue illness is an important measure of dengue morbidity. However, limited studies are based on administrative database because the validity of the diagnosis codes is unknown. We validated the International Classification of Diseases, 10th revision (ICD) diagnosis coding for dengue infections in the Malaysian Ministry of Health's (MOH) hospital discharge database. This validation study involves retrospective review of available hospital discharge records and hand-search medical records for years 2010 and 2013. We randomly selected 3219 hospital discharge records coded with dengue and non-dengue infections as their discharge diagnoses from the national hospital discharge database. We then randomly sampled 216 and 144 records for patients with and without codes for dengue respectively, in keeping with their relative frequency in the MOH database, for chart review. The ICD codes for dengue were validated against lab-based diagnostic standard (NS1 or IgM). The ICD-10-CM codes for dengue had a sensitivity of 94%, modest specificity of 83%, positive predictive value of 87% and negative predictive value 92%. These results were stable between 2010 and 2013. However, its specificity decreased substantially when patients manifested with bleeding or low platelet count. The diagnostic performance of the ICD codes for dengue in the MOH's hospital discharge database is adequate for use in health services research on dengue.

  7. Bar Coding and Tracking in Pathology.

    Science.gov (United States)

    Hanna, Matthew G; Pantanowitz, Liron

    2016-03-01

    Bar coding and specimen tracking are intricately linked to pathology workflow and efficiency. In the pathology laboratory, bar coding facilitates many laboratory practices, including specimen tracking, automation, and quality management. Data obtained from bar coding can be used to identify, locate, standardize, and audit specimens to achieve maximal laboratory efficiency and patient safety. Variables that need to be considered when implementing and maintaining a bar coding and tracking system include assets to be labeled, bar code symbologies, hardware, software, workflow, and laboratory and information technology infrastructure as well as interoperability with the laboratory information system. This article addresses these issues, primarily focusing on surgical pathology. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. 14 CFR 1260.142 - Codes of conduct.

    Science.gov (United States)

    2010-01-01

    ..., Hospitals, and Other Non-Profit Organizations Procurement Standards § 1260.142 Codes of conduct. The..., recipients may set standards for situations in which the financial interest is not substantial or the gift is...

  9. 38 CFR 49.42 - Codes of conduct.

    Science.gov (United States)

    2010-07-01

    ... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 49.42 Codes of conduct. The..., recipients may set standards for situations in which the financial interest is not substantial or the gift is...

  10. 14 CFR 1274.503 - Codes of conduct.

    Science.gov (United States)

    2010-01-01

    ... FIRMS Procurement Standards § 1274.503 Codes of conduct. The recipient shall maintain written standards... situations in which the financial interest is not substantial or the gift is an unsolicited item of nominal...

  11. 40 CFR 30.42 - Codes of conduct.

    Science.gov (United States)

    2010-07-01

    ... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 30.42 Codes of conduct. The..., recipients may set standards for situations in which the financial interest is not substantial or the gift is...

  12. 32 CFR 32.42 - Codes of conduct.

    Science.gov (United States)

    2010-07-01

    ... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 32.42 Codes of conduct. The..., recipients may set standards for situations in which the financial interest is not substantial or the gift is...

  13. 78 FR 35585 - Updating OSHA Standards Based on National Consensus Standards; Signage

    Science.gov (United States)

    2013-06-13

    ...; Signage AGENCY: Occupational Safety and Health Administration (OSHA), Department of Labor. ACTION: Notice... Administration (``OSHA'' or ``the Agency'') proposes to update its general industry and construction signage... standards, ANSI Z53.1-1967, Z35.1-1968, and Z35.2-1968, in its signage standards, thereby providing...

  14. Code on the safety of civilian nuclear fuel cycle installations

    International Nuclear Information System (INIS)

    1996-01-01

    The 'Code' was promulgated by the National Nuclear Safety Administration (NSSA) on June 17, 1993, which is applicable to civilian nuclear fuel fabrication, processing, storage and reprocessing installations, not including the safety requirements for the use of nuclear fuel in reactors. The contents of the 'Code' involve siting, design, construction, commissioning, operation and decommissioning of fuel cycle installation. The NNSA shall be responsible for the interpretation of this 'Code'

  15. 22 CFR 145.42 - Code of conduct.

    Science.gov (United States)

    2010-04-01

    ..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 145.42 Code of... substantial or the gift is an unsolicited item of nominal value. The standards of conduct shall provide for...

  16. 24 CFR 84.42 - Codes of conduct.

    Science.gov (United States)

    2010-04-01

    ..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 84.42 Codes of... substantial or the gift is an unsolicited item of nominal value. The standards of conduct shall provide for...

  17. 49 CFR 19.42 - Codes of conduct.

    Science.gov (United States)

    2010-10-01

    ... Requirements Procurement Standards § 19.42 Codes of conduct. The recipient shall maintain written standards of... situations in which the financial interest is not substantial or the gift is an unsolicited item of nominal...

  18. Validation of the ASSERT subchannel code: Prediction of critical heat flux in standard and nonstandard CANDU bundle geometries

    International Nuclear Information System (INIS)

    Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.

    1995-01-01

    The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of Canada uranium deuterium (CANDU) pressurized heavy water reactor fuel channels and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting CHF at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental database. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. The numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology are discussed. The evolutionary validation plan is also discussed and early validation exercises are summarized. More recent validation exercises in standard and nonstandard geometries are emphasized

  19. 5 CFR 179.309 - Additional administrative procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Additional administrative procedures. 179.309 Section 179.309 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.309 Additional administrative procedures. Nothing...

  20. 28 CFR 36.204 - Administrative methods.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Administrative methods. 36.204 Section 36... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES General Requirements § 36.204 Administrative methods... standards or criteria or methods of administration that have the effect of discriminating on the basis of...

  1. Hybrid Video Coding Based on Bidimensional Matching Pursuit

    Directory of Open Access Journals (Sweden)

    Lorenzo Granai

    2004-12-01

    Full Text Available Hybrid video coding combines together two stages: first, motion estimation and compensation predict each frame from the neighboring frames, then the prediction error is coded, reducing the correlation in the spatial domain. In this work, we focus on the latter stage, presenting a scheme that profits from some of the features introduced by the standard H.264/AVC for motion estimation and replaces the transform in the spatial domain. The prediction error is so coded using the matching pursuit algorithm which decomposes the signal over an appositely designed bidimensional, anisotropic, redundant dictionary. Comparisons are made among the proposed technique, H.264, and a DCT-based coding scheme. Moreover, we introduce fast techniques for atom selection, which exploit the spatial localization of the atoms. An adaptive coding scheme aimed at optimizing the resource allocation is also presented, together with a rate-distortion study for the matching pursuit algorithm. Results show that the proposed scheme outperforms the standard DCT, especially at very low bit rates.

  2. QUIL: a chemical equilibrium code

    International Nuclear Information System (INIS)

    Lunsford, J.L.

    1977-02-01

    A chemical equilibrium code QUIL is described, along with two support codes FENG and SURF. QUIL is designed to allow calculations on a wide range of chemical environments, which may include surface phases. QUIL was written specifically to calculate distributions associated with complex equilibria involving fission products in the primary coolant loop of the high-temperature gas-cooled reactor. QUIL depends upon an energy-data library called ELIB. This library is maintained by FENG and SURF. FENG enters into the library all reactions having standard free energies of reaction that are independent of concentration. SURF enters all surface reactions into ELIB. All three codes are interactive codes written to be used from a remote terminal, with paging control provided. Plotted output is also available

  3. Code of practice for food handler activities.

    Science.gov (United States)

    Smith, T A; Kanas, R P; McCoubrey, I A; Belton, M E

    2005-08-01

    The food industry regulates various aspects of food handler activities, according to legislation and customer expectations. The purpose of this paper is to provide a code of practice which delineates a set of working standards for food handler hygiene, handwashing, use of protective equipment, wearing of jewellery and body piercing. The code was developed by a working group of occupational physicians with expertise in both food manufacturing and retail, using a risk assessment approach. Views were also obtained from other occupational physicians working within the food industry and the relevant regulatory bodies. The final version of the code (available in full as Supplementary data in Occupational Medicine Online) therefore represents a broad consensus of opinion. The code of practice represents a set of minimum standards for food handler suitability and activities, based on a practical assessment of risk, for application in food businesses. It aims to provide useful working advice to food businesses of all sizes.

  4. Comparative analysis of ethical codes for state administration in the Republic of Macedonia and nearby states

    Directory of Open Access Journals (Sweden)

    Marina Malis Sazdovska

    2017-03-01

    Full Text Available Professional Ethic is the professional set of standards that describe the professional behavior that is expected in all fields of work. Professional Ethics examines the moral and ethical issues that arise in a corporate environment. The basic ethics a responsible and reliable employee practices are that he stays productive and takes responsibility for his action, and that includes being accountable for the good or bad consequences of his actions. Morals are the welfare principles enunciated by the wise people, based on their experience and wisdom. They were edited, changed or modified or evolved to suit the geography of the region, rulers and in accordance with development of knowledge in science and technology and with time. This paper analyzes the comparison of the professional code of conduct of civil servants in all neighboring countries including the Republic of Macedonia. Particular importance is given to similarities and differences in each neighboring country including the Republic of Macedonia.

  5. Bi-level image compression with tree coding

    DEFF Research Database (Denmark)

    Martins, Bo; Forchhammer, Søren

    1996-01-01

    Presently, tree coders are the best bi-level image coders. The current ISO standard, JBIG, is a good example. By organising code length calculations properly a vast number of possible models (trees) can be investigated within reasonable time prior to generating code. Three general-purpose coders...... are constructed by this principle. A multi-pass free tree coding scheme produces superior compression results for all test images. A multi-pass fast free template coding scheme produces much better results than JBIG for difficult images, such as halftonings. Rissanen's algorithm `Context' is presented in a new...

  6. Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging.

    Science.gov (United States)

    Suntharalingam, Saravanabavaan; Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael; Nassenstein, Kai

    2017-01-01

    To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; pcontrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%.

  7. Benefit using reasonable regulations in USA, how to skill up on professional engineers, apply international code, standard, and regulation

    International Nuclear Information System (INIS)

    Turner, S.L.; Morokuzu, Muneo; Amano, Osamu

    2005-01-01

    The reasonable regulations in USA consist of a graduated approach and a risk informed approach (RIA). RIA rationalizes the regulations on the basis of data of operations etc. PSA (Probabilistic Safety Assessment), a general method of RIA, is explained in detail. The benefits of nuclear power plant using RIA are increase of the rate of operation, visualization of risk, application of design standard and design, cost down of nuclear fuel cycle, waste, production and operation, and safety. RIA is supported by the field data, code, standard, regulation and professional engineers. The effects of introduction of RIA are explained. In order to introduce RIA in Japan, all the parties concerned such as the regulation authorities, the electric power industries, makers, universities, have to understand it and work together. A part of scientific society is stated. (S.Y.)

  8. Effects of administration of the standardized Panax ginseng extract G115 on hepatic antioxidant function after exhaustive exercise.

    Science.gov (United States)

    Voces, J; Alvarez, A I; Vila, L; Ferrando, A; Cabral de Oliveira, C; Prieto, J G

    1999-06-01

    The effect of prolonged treatment with the standardized Panax ginseng extract G115 on the antioxidant capacity of the liver was investigated. For this purpose, rats that had received G115 orally at different doses for 3 months and untreated control rats were subjected to exhaustive exercise on a treadmill. A bell-shaped dose response on running time was obtained. The results showed that the administration of G115 significantly increases the hepatic glutathione peroxidase activity (GPX) and the reduced glutathione (GSH) levels in the liver, with a dose-dependent reduction of the thiobarbituric acid reactant substances (TBARS). After the exercise, there is reduced hepatic lipid peroxidation, as evidenced by the TBARS levels in both the controls and the treated animals. The GPX (glutathione peroxidase) and SOD (superoxide dismutase) activity are also significantly increased in the groups receiving G115, compared with the controls. The hepatic transaminase levels, ALT (Alanine-amino-transferase) and AST (Aspartate-amino-transferase), in the recuperation phase 48 h after the exercise, indicate a clear hepatoprotective effect related to the administration of the standardized Panax ginseng extract G115. At hepatic level, G115 increases the antioxidant capacity, with a marked reduction of the effects of the oxidative stress induced by the exhaustive exercise.

  9. City Reach Code Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Frankel, Mark [New Buildings Inst., Portland, OR (United States); Lyles, Mark [New Buildings Inst., Portland, OR (United States)

    2017-10-31

    This report describes and analyzes a set of energy efficiency measures that will save 20% energy over ASHRAE Standard 90.1-2013. The measures will be used to formulate a Reach Code for cities aiming to go beyond national model energy codes. A coalition of U.S. cities together with other stakeholders wanted to facilitate the development of voluntary guidelines and standards that can be implemented in stages at the city level to improve building energy efficiency. The coalition's efforts are being supported by the U.S. Department of Energy via Pacific Northwest National Laboratory (PNNL) and in collaboration with the New Buildings Institute.

  10. Building Energy Codes: Policy Overview and Good Practices

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Sadie [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-19

    Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

  11. Bring out your codes! Bring out your codes! (Increasing Software Visibility and Re-use)

    Science.gov (United States)

    Allen, A.; Berriman, B.; Brunner, R.; Burger, D.; DuPrie, K.; Hanisch, R. J.; Mann, R.; Mink, J.; Sandin, C.; Shortridge, K.; Teuben, P.

    2013-10-01

    Progress is being made in code discoverability and preservation, but as discussed at ADASS XXI, many codes still remain hidden from public view. With the Astrophysics Source Code Library (ASCL) now indexed by the SAO/NASA Astrophysics Data System (ADS), the introduction of a new journal, Astronomy & Computing, focused on astrophysics software, and the increasing success of education efforts such as Software Carpentry and SciCoder, the community has the opportunity to set a higher standard for its science by encouraging the release of software for examination and possible reuse. We assembled representatives of the community to present issues inhibiting code release and sought suggestions for tackling these factors. The session began with brief statements by panelists; the floor was then opened for discussion and ideas. Comments covered a diverse range of related topics and points of view, with apparent support for the propositions that algorithms should be readily available, code used to produce published scientific results should be made available, and there should be discovery mechanisms to allow these to be found easily. With increased use of resources such as GitHub (for code availability), ASCL (for code discovery), and a stated strong preference from the new journal Astronomy & Computing for code release, we expect to see additional progress over the next few years.

  12. Paraguay; Report on the Observance of Standards and Codes: FATF Recommendations for Anti-Money Laundering and Combating the Financing of Terrorism

    OpenAIRE

    International Monetary Fund

    2009-01-01

    This paper discusses assessment results on the observance of standards and codes on the Financial Action Task Force (FATF) recommendations for antimoney laundering and combating the financing of terrorism (AML/CFT) for Paraguay. The assessment reveals that the substantial U.S. dollar contraband trade that occurs on the borders shared with Argentina and Brazil facilitates money laundering in Paraguay. Achievements in the implementation of Paraguay’s AML framework remain modest since the crimin...

  13. Development of an accident consequence assessment code for evaluating site suitability of light- and heavy-water reactors based on the Korean Technical standards

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Won Tae; Jeong, Hae Sung; Jeong, Hyo Joon; Kil, A Reum; Kim, Eun Han; Han, Moon Hee [Nuclear Environment Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Methodologies for a series of radiological consequence assessments show a distinctive difference according to the design principles of the original nuclear suppliers and their technical standards to be imposed. This is due to the uncertainties of the accidental source term, radionuclide behavior in the environment, and subsequent radiological dose. Both types of PWR and PHWR are operated in Korea. However, technical standards for evaluating atmospheric dispersion have been enacted based on the U.S. NRC's positions regardless of the reactor types. For this reason, it might cause a controversy between the licensor and licensee of a nuclear power plant. It was modelled under the framework of the NRC Regulatory Guide 1.145 for light-water reactors, reflecting the features of heavy-water reactors as specified in the Canadian National Standard and the modelling features in MACCS2, such as atmospheric diffusion coefficient, ground deposition, surface roughness, radioactive plume depletion, and exposure from ground deposition. An integrated accident consequence assessment code, ACCESS (Accident Consequence Assessment Code for Evaluating Site Suitability), was developed by taking into account the unique regulatory positions for reactor types under the framework of the current Korean technical standards. Field tracer experiments and hand calculations have been carried out for validation and verification of the models. The modelling approaches of ACCESS and its features are introduced, and its applicative results for a hypothetical accidental scenario are comprehensively discussed. In an applicative study, the predicted results by the light-water reactor assessment model were higher than those by other models in terms of total doses.

  14. MOTIVATION OF ADMINISTRATIVE ACTS – GUARANTEE OF GOOD ADMINISTRATION

    Directory of Open Access Journals (Sweden)

    Adelin Mihai ZĂGĂRIN

    2018-05-01

    Full Text Available The present article deals with the aspects of motivating administrative acts, both doctrinaire and practical, of jurisprudence. The duty of the administration to motivate its decisions is submitted in the Charter of Fundamental Rights of the European Union, art. 41. In the current European legal order, the rationale for administrative acts is considered and refers to one of the most important conditions of validity of the administrative act. The Romanian Constitution ensures and emphasizes the motivation, as it is imposed by the Charter. The realization of this fundamental right to motivate administrative acts is possible by calling upon a set of values from the administration, such as transparency, professionalism and the imposition of high quality standards. Motivation is achieved where we have a good administration, and whether citizens are, among other things, respected fundamental rights and freedoms, access to information is guaranteed and motivated their decisions. Although administrative normative acts are motivated by the administration, examples that show that individual ones are unmotivated or incompletely motivated are enough, which made the various employers legally answer for the non-motivation of their decisions to terminate work relationships with several of the employees. The motivation of administrative acts is necessary, mandatory and must be done with rigor. It is highlighted that inadequate, incomplete or vicious reasoning may result in suspension or even annulment of the administrative act by the court.

  15. Code of Practice for the safe transport of radioactive substances 1990

    International Nuclear Information System (INIS)

    1990-01-01

    This Federal Code revises an earlier Code on the same subject issued in 1982 and was formulated under the Environment Protection (Nuclear Codes) Act 1978. The purpose of the Code is to establish uniform safety standards, applicable throughout the Commonwealth of Australia, to provide for the protection of persons and the environment, against any dangers associated with the transport of radioactive substances. The Code uses as a basis the IAEA Regulations for the Safe Transport of Radioactive Materials. This new edition takes into account the 1985 Edition of the Regulations incorporating the 1988 Supplement and provides, furthermore, that radiation protection standards will also be subject to recommendations of the Australian National Health and Medical Research Council [fr

  16. Establishment of a New Drug Code for Marihuana Extract. Final rule.

    Science.gov (United States)

    2016-12-14

    The Drug Enforcement Administration is creating a new Administration Controlled Substances Code Number for "Marihuana Extract." This code number will allow DEA and DEA-registered entities to track quantities of this material separately from quantities of marihuana. This, in turn, will aid in complying with relevant treaty provisions. Under international drug control treaties administered by the United Nations, some differences exist between the regulatory controls pertaining to marihuana extract versus those for marihuana and tetrahydrocannabinols. The DEA has previously established separate code numbers for marihuana and for tetrahydrocannabinols, but not for marihuana extract. To better track these materials and comply with treaty provisions, DEA is creating a separate code number for marihuana extract with the following definition: "Meaning an extract containing one or more cannabinoids that has been derived from any plant of the genus Cannabis, other than the separated resin (whether crude or purified) obtained from the plant." Extracts of marihuana will continue to be treated as Schedule I controlled substances.

  17. Tree Coding of Bilevel Images

    DEFF Research Database (Denmark)

    Martins, Bo; Forchhammer, Søren

    1998-01-01

    Presently, sequential tree coders are the best general purpose bilevel image coders and the best coders of halftoned images. The current ISO standard, Joint Bilevel Image Experts Group (JBIG), is a good example. A sequential tree coder encodes the data by feeding estimates of conditional...... is one order of magnitude slower than JBIG, obtains excellent and highly robust compression performance. A multipass free tree coding scheme produces superior compression results for all test images. A multipass free template coding scheme produces significantly better results than JBIG for difficult...... images such as halftones. By utilizing randomized subsampling in the template selection, the speed becomes acceptable for practical image coding...

  18. Multimedia signal coding and transmission

    CERN Document Server

    Ohm, Jens-Rainer

    2015-01-01

    This textbook covers the theoretical background of one- and multidimensional signal processing, statistical analysis and modelling, coding and information theory with regard to the principles and design of image, video and audio compression systems. The theoretical concepts are augmented by practical examples of algorithms for multimedia signal coding technology, and related transmission aspects. On this basis, principles behind multimedia coding standards, including most recent developments like High Efficiency Video Coding, can be well understood. Furthermore, potential advances in future development are pointed out. Numerous figures and examples help to illustrate the concepts covered. The book was developed on the basis of a graduate-level university course, and most chapters are supplemented by exercises. The book is also a self-contained introduction both for researchers and developers of multimedia compression systems in industry.

  19. Energy Code Enforcement Training Manual : Covering the Washington State Energy Code and the Ventilation and Indoor Air Quality Code.

    Energy Technology Data Exchange (ETDEWEB)

    Washington State Energy Code Program

    1992-05-01

    This manual is designed to provide building department personnel with specific inspection and plan review skills and information on provisions of the 1991 edition of the Washington State Energy Code (WSEC). It also provides information on provisions of the new stand-alone Ventilation and Indoor Air Quality (VIAQ) Code.The intent of the WSEC is to reduce the amount of energy used by requiring energy-efficient construction. Such conservation reduces energy requirements, and, as a result, reduces the use of finite resources, such as gas or oil. Lowering energy demand helps everyone by keeping electricity costs down. (It is less expensive to use existing electrical capacity efficiently than it is to develop new and additional capacity needed to heat or cool inefficient buildings.) The new VIAQ Code (effective July, 1991) is a natural companion to the energy code. Whether energy-efficient or not, an homes have potential indoor air quality problems. Studies have shown that indoor air is often more polluted than outdoor air. The VIAQ Code provides a means of exchanging stale air for fresh, without compromising energy savings, by setting standards for a controlled ventilation system. It also offers requirements meant to prevent indoor air pollution from building products or radon.

  20. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    Science.gov (United States)

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  1. Methodology for Evaluating Cost-effectiveness of Commercial Energy Code Changes

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-01-31

    This document lays out the U.S. Department of Energy’s (DOE’s) method for evaluating the cost-effectiveness of energy code proposals and editions. The evaluation is applied to provisions or editions of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 90.1 and the International Energy Conservation Code (IECC). The method follows standard life-cycle cost (LCC) economic analysis procedures. Cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes, 2) evaluating the incremental and replacement costs related to the changes, and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

  2. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  3. Osteoporosis-related fracture case definitions for population-based administrative data

    Directory of Open Access Journals (Sweden)

    Lix Lisa M

    2012-05-01

    Full Text Available Abstract Background Population-based administrative data have been used to study osteoporosis-related fracture risk factors and outcomes, but there has been limited research about the validity of these data for ascertaining fracture cases. The objectives of this study were to: (a compare fracture incidence estimates from administrative data with estimates from population-based clinically-validated data, and (b test for differences in incidence estimates from multiple administrative data case definitions. Methods Thirty-five case definitions for incident fractures of the hip, wrist, humerus, and clinical vertebrae were constructed using diagnosis codes in hospital data and diagnosis and service codes in physician billing data from Manitoba, Canada. Clinically-validated fractures were identified from the Canadian Multicentre Osteoporosis Study (CaMos. Generalized linear models were used to test for differences in incidence estimates. Results For hip fracture, sex-specific differences were observed in the magnitude of under- and over-ascertainment of administrative data case definitions when compared with CaMos data. The length of the fracture-free period to ascertain incident cases had a variable effect on over-ascertainment across fracture sites, as did the use of imaging, fixation, or repair service codes. Case definitions based on hospital data resulted in under-ascertainment of incident clinical vertebral fractures. There were no significant differences in trend estimates for wrist, humerus, and clinical vertebral case definitions. Conclusions The validity of administrative data for estimating fracture incidence depends on the site and features of the case definition.

  4. 22 CFR 226.47 - Contract administration.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Contract administration. 226.47 Section 226.47 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Procurement Standards § 226.47 Contract administration. A...

  5. Summary description of the scale modular code system

    International Nuclear Information System (INIS)

    Parks, C.V.

    1987-12-01

    SCALE - a modular code system for Standardized Computer Analyses for Licensing Evaluation - has been developed at Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission staff. The SCALE system utilizes well-established computer codes and methods within standard analytic sequences that allow simplified free-form input, automate the data processing and coupling between codes, and provide accurate and reliable results. System development has been directed at criticality safety, shielding, and heat transfer analysis of spent fuel transport and/or storage casks. However, only a few of the sequences (and none of the individual functional modules) are restricted to cask applications. This report will provide a background on the history of the SCALE development and review the components and their function within the system. The available data libraries are also discussed, together with the automated features that standardize the data processing and systems analysis. 83 refs., 32 figs., 11 tabs

  6. The RETRAN-03 computer code

    International Nuclear Information System (INIS)

    Paulsen, M.P.; McFadden, J.H.; Peterson, C.E.; McClure, J.A.; Gose, G.C.; Jensen, P.J.

    1991-01-01

    The RETRAN-03 code development effort is designed to overcome the major theoretical and practical limitations associated with the RETRAN-02 computer code. The major objectives of the development program are to extend the range of analyses that can be performed with RETRAN, to make the code more dependable and faster running, and to have a more transportable code. The first two objectives are accomplished by developing new models and adding other models to the RETRAN-02 base code. The major model additions for RETRAN-03 are as follows: implicit solution methods for the steady-state and transient forms of the field equations; additional options for the velocity difference equation; a new steady-state initialization option for computer low-power steam generator initial conditions; models for nonequilibrium thermodynamic conditions; and several special-purpose models. The source code and the environmental library for RETRAN-03 are written in standard FORTRAN 77, which allows the last objective to be fulfilled. Some models in RETRAN-02 have been deleted in RETRAN-03. In this paper the changes between RETRAN-02 and RETRAN-03 are reviewed

  7. Structural reliability codes for probabilistic design

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager

    1997-01-01

    probabilistic code format has not only strong influence on the formal reliability measure, but also on the formal cost of failure to be associated if a design made to the target reliability level is considered to be optimal. In fact, the formal cost of failure can be different by several orders of size for two...... different, but by and large equally justifiable probabilistic code formats. Thus, the consequence is that a code format based on decision theoretical concepts and formulated as an extension of a probabilistic code format must specify formal values to be used as costs of failure. A principle of prudence...... is suggested for guiding the choice of the reference probabilistic code format for constant reliability. In the author's opinion there is an urgent need for establishing a standard probabilistic reliability code. This paper presents some considerations that may be debatable, but nevertheless point...

  8. Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig

    2014-01-01

    Land administration systems are the operational tool for conceptualizing rights, restrictions and responsibilities (RRRs) in land. Each of the rights, restrictions and responsibilities encompasses a human rights dimension that relates to the overall national land policies and should be unfolded...... as more than just rhetoric. This paper attempts to analyse the aspects of human rights in relation to land administration systems with a special focus on developing countries struggling to build adequate systems for governing the rights, restrictions and responsibilities in land. Human rights....... This relates to national political arrangements and standards for good governance and land administration systems are highly instrumental in this regard. This paper introduces the relation between land administration and human rights. It is argued that human rights and land administration are closely linked...

  9. APC-II: an electron beam propagation code

    International Nuclear Information System (INIS)

    Iwan, D.C.; Freeman, J.R.

    1984-05-01

    The computer code APC-II simulates the propagation of a relativistic electron beam through air. APC-II is an updated version of the APC envelope model code. It incorporates an improved conductivity model which significantly extends the range of stable calculations. A number of test cases show that these new models are capable of reproducing the simulations of the original APC code. As the result of a major restructuring and reprogramming of the code, APC-II is now friendly to both the occasional user and the experienced user who wishes to make modifications. Most of the code is in standard ANS-II Fortran 77 so that it can be easily transported between machines

  10. JPEG2000 COMPRESSION CODING USING HUMAN VISUAL SYSTEM MODEL

    Institute of Scientific and Technical Information of China (English)

    Xiao Jiang; Wu Chengke

    2005-01-01

    In order to apply the Human Visual System (HVS) model to JPEG2000 standard,several implementation alternatives are discussed and a new scheme of visual optimization isintroduced with modifying the slope of rate-distortion. The novelty is that the method of visual weighting is not lifting the coefficients in wavelet domain, but is complemented by code stream organization. It remains all the features of Embedded Block Coding with Optimized Truncation (EBCOT) such as resolution progressive, good robust for error bit spread and compatibility of lossless compression. Well performed than other methods, it keeps the shortest standard codestream and decompression time and owns the ability of VIsual Progressive (VIP) coding.

  11. French administrative practice and design codes for nuclear vessels

    International Nuclear Information System (INIS)

    Roche, R.L.

    1987-07-01

    French regulations on boilers and pressure vessels have prevailed for a very long time, the first measure having been promulgated on 29 October 1823. Restraining the attention to nuclear pressure vessels it must be pointed out regulations and enforcement by public authorities are more stringent than they are for conventional pressure vessels. The first part of this paper will be devoted to regulations with a special attention to the decree of 26 February 1974 and to the practice of public authorities in this field with special attention given to the Bureau de Controle de la Construction Nucleaire (BCCN = Bureau of Inspection of Nuclear Design and Manufacturing). The second part of this paper will deal with the French construction codes for nuclear components RCC-M (water reactors) and RCC-MR (elevated temperature design)

  12. Standardized mappings--a framework to combine different semantic mappers into a standardized web-API.

    Science.gov (United States)

    Neuhaus, Philipp; Doods, Justin; Dugas, Martin

    2015-01-01

    Automatic coding of medical terms is an important, but highly complicated and laborious task. To compare and evaluate different strategies a framework with a standardized web-interface was created. Two UMLS mapping strategies are compared to demonstrate the interface. The framework is a Java Spring application running on a Tomcat application server. It accepts different parameters and returns results in JSON format. To demonstrate the framework, a list of medical data items was mapped by two different methods: similarity search in a large table of terminology codes versus search in a manually curated repository. These mappings were reviewed by a specialist. The evaluation shows that the framework is flexible (due to standardized interfaces like HTTP and JSON), performant and reliable. Accuracy of automatically assigned codes is limited (up to 40%). Combining different semantic mappers into a standardized Web-API is feasible. This framework can be easily enhanced due to its modular design.

  13. International standard problem (ISP) No. 43 Rapid boron-dilution transient tests for code verification. Comparison report

    International Nuclear Information System (INIS)

    2001-03-01

    International Standard Problem No. 43 (ISP 43) addresses the nuclear industries present capabilities of simulating fluid dynamics aspects of a subset of rapid boron dilution transients. Specifically, the exercise focuses on the sequence involving the transport of a boron-dilute slug through the actuation of a pump. The slug is formed on the primary side of the steam generator as a consequence of in interfacing system leak from the secondary un-borated coolant. Experimental data was collected using the University of Maryland 2 x 4 Thermalhydraulic Loop (UM 2 x 4 Loop) and the Boron-mixing Visualization Facility. Two blind test series were proposed during the first workshop (October 1998) and refined using participant input. The first series, test series A, deals with the injection of a front, i.e., a single interface between borated and dilute fluids. The second blind series, test series B, is the more realistic injection of a slug, i.e., a dilute fluid volume preceded and followed by the borated coolant of the primary system. Data are collected in the UM 2 x 4 Loop and refined details are obtained from the Visualization Facility, which represents a replica of the Loop.s vessel downcomer. In the Loop experimental program, the dilute volume is simulated by cold water and the borated primary coolant is simulated by hot water. The Visualization Facility uses dye to mark the diluted front or slug. The measured boundary conditions for both test series include the initial temperature of the primary system, the front/slug injection flowrate and temperature, and the pressure drop across the core. Temperature data is collected at 185 thermocouple positions in the downcomer and 38 positions in the lower plenum. The advancement of the front/slug through the system is monitored at discrete horizontal levels that contain the thermocouples. The performance of codes is measured relative to a set of figures of merit. During the first workshop, the principal figure of merit was

  14. On the administrative law accessoriness of art. 327 of the Penal Code

    International Nuclear Information System (INIS)

    Dolde, K.P.

    1988-01-01

    The essay deals with the binding of criminal law on valid permissions given by authorities. Criminal courts are bound on the content of valid administrative acts, even when those are against the law but not invalid. By not considering administrative permissions, criminal courts ignore the binding force of official acts. They infringe the prohibition not to diverge from a valid act even when the addresse of the act knows that it is against the law. (KW) [de

  15. 75 FR 24323 - American Society of Mechanical Engineers (ASME) Codes and New and Revised ASME Code Cases

    Science.gov (United States)

    2010-05-04

    ...The NRC proposes to amend its regulations to incorporate by reference the 2005 Addenda through 2008 Addenda of Section III, Division 1, and the 2005 Addenda through 2008 Addenda of Section XI, Division 1, of the ASME Boiler and Pressure Vessel Code (ASME B&PV Code); and the 2005 Addenda and 2006 Addenda of the ASME Code for Operation and Maintenance of Nuclear Power Plants (ASME OM Code). The NRC also proposes to incorporate by reference ASME Code Case N-722-1, ``Additional Examinations for PWR Pressure Retaining Welds in Class 1 Components Fabricated With Alloy 600/82/182 Materials Section XI, Division 1,'' and Code Case N-770, ``Alternative Examination Requirements and Acceptance Standards for Class 1 PWR [Pressurized- Water Reactor] Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material with or without Application of Listed Mitigation Activities.''

  16. Education and Criminal Justice: The Educational Approach to Prison Administration. The United Nations Standard Minimum Rules for the Treatment of Prisoners.

    Science.gov (United States)

    Morin, Lucien; Cosman, J. W.

    The United Nations Standard Minimum Rules for the Treatment of Prisoners do not express the basic principle that would support a serious educational approach to prison administration. The crucial missing rationale is the concept of the inherent dignity of the individual human prisoner. This concept has certain basic educational implications,…

  17. Impact of School Uniforms on Student Discipline and the Learning Climate: A Comparative Case Study of Two Middle Schools with Uniform Dress Codes and Two Middle Schools without Uniform Dress Codes

    Science.gov (United States)

    Dulin, Charles Dewitt

    2016-01-01

    The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…

  18. International standard problem (ISP) No. 41. Containment iodine computer code exercise based on a radioiodine test facility (RTF) experiment

    International Nuclear Information System (INIS)

    2000-04-01

    International Standard Problem (ISP) exercises are comparative exercises in which predictions of different computer codes for a given physical problem are compared with each other or with the results of a carefully controlled experimental study. The main goal of ISP exercises is to increase confidence in the validity and accuracy of the tools, which were used in assessing the safety of nuclear installations. Moreover, they enable code users to gain experience and demonstrate their competence. The ISP No. 41 exercise, computer code exercise based on a Radioiodine Test Facility (RTF) experiment on iodine behaviour in containment under severe accident conditions, is one of such ISP exercises. The ISP No. 41 exercise was borne at the recommendation at the Fourth Iodine Chemistry Workshop held at PSI, Switzerland in June 1996: 'the performance of an International Standard Problem as the basis of an in-depth comparison of the models as well as contributing to the database for validation of iodine codes'. [Proceedings NEA/CSNI/R(96)6, Summary and Conclusions NEA/CSNI/R(96)7]. COG (CANDU Owners Group), comprising AECL and the Canadian nuclear utilities, offered to make the results of a Radioiodine Test Facility (RTF) test available for such an exercise. The ISP No. 41 exercise was endorsed in turn by the FPC (PWG4's Task Group on Fission Product Phenomena in the Primary Circuit and the Containment), PWG4 (CSNI Principal Working Group on the Confinement of Accidental Radioactive Releases), and the CSNI. The OECD/NEA Committee on the Safety of Nuclear Installations (CSNI) has sponsored forty-five ISP exercises over the last twenty-four years, thirteen of them in the area of severe accidents. The criteria for the selection of the RTF test as a basis for the ISP-41 exercise were; (1) complementary to other RTF tests available through the PHEBUS and ACE programmes, (2) simplicity for ease of modelling and (3) good quality data. A simple RTF experiment performed under controlled

  19. Analysis of visual coding variables on CRT generated displays

    International Nuclear Information System (INIS)

    Blackman, H.S.; Gilmore, W.E.

    1985-01-01

    Cathode ray tube generated safety parameter display systems in a nuclear power plant control room situation have been found to be improved in effectiveness when color coding is employed. Research has indicated strong support for graphic coding techniques particularly in redundant coding schemes. In addition, findings on pictographs, as applied in coding schemes, indicate the need for careful application and for further research in the development of a standardized set of symbols

  20. Standard problems for structural computer codes

    International Nuclear Information System (INIS)

    Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.

    1985-01-01

    BNL is investigating the ranges of validity of the analytical methods used to predict the behavior of nuclear safety related structures under accidental and extreme environmental loadings. During FY 85, the investigations were concentrated on special problems that can significantly influence the outcome of the soil structure interaction evaluation process. Specially, limitations and applicability of the standard interaction methods when dealing with lift-off, layering and water table effects, were investigated. This paper describes the work and the results obtained during FY 85 from the studies on lift-off, layering and water-table effects in soil-structure interaction