WorldWideScience

Sample records for standard 3800-mwt pwr

  1. PWR standardization: The French experience

    International Nuclear Information System (INIS)

    Bacher, P.E.

    1987-01-01

    After a short historical review of the French PWR programme with 45000 MWe in operation and 15000 MWe under construction, the paper first develops the objectives and limits of the standardizatoin policy. Implementation of standardization is described through successive reactor series and feedback of experience, together with its impact on safety and on codes and standards. Present benefits of standardization range from low engineering costs to low backfitting costs, via higher quality, reduction in construction times and start-up schedules and improved training of operators. The future of the French programme into the 1990's is again with an advanced standardized series, the N4-1400 MW plant. There is no doubt that the very positive experience with standardization is relevant to any country trying to achieve self-reliance in the nuclear power field. (author)

  2. Standardization of PWR power plants: Impact of capital investment cost

    International Nuclear Information System (INIS)

    Vincent, C.

    1991-01-01

    The French program is certainly specific to the French context but it is a large and a real experiment of standardized series of units from which we can abstract the main ideas and ranges available in different contexts. It was estimated that the standardized part could reach more than 60% of the capital cost and this percentage does not take into account a regionalized part which also could have been standardized. The main condition is a large program which could be issued from a country or a partnership between different countries. That means, common terms of reference, lists of standardized equipment, same design documents. With a levelized rhythm of erection, beneficial effects of the series could be expected. The scale effect is fairly well known, also we can wonder for instance about the choice between five units of 600 MW and three units of 1000 MW. The answer is depending on the number of units and on the discount rate. (author)

  3. Thermal hydraulic design of hydride fueled PWR cores

    International Nuclear Information System (INIS)

    Malen, J.A.; Todreas, N.E.; Romano, A.

    2004-01-01

    The neutronic characteristics of hydride fuels permit increased fuel to coolant volume ratios in the core. A parametric study was developed to determine the optimum combination of lattice pitch, rod diameter, and channel shape - further referred to as geometry - for minimizing the total cost of operating existing PWRs loaded with UZrH 1.6 fuel. Results of the thermal hydraulic and fuel performance studies are presented here, and will be integrated into an economic model in the next stage of the research. The thermal hydraulic analysis was used to determine the maximum power that can be achieved by a given geometry, subject to four constraints - MDNBR, pressure drop, fuel temperature, and coolant flow velocity. The fuel performance analysis was used to determine the maximum burnup that can be achieved by a given geometry, subject to three additional constraints - fuel internal pressure and fission gas release, clad oxidation, and clad strain. This methodology was successfully validated by comparison of the predicted power and burnup of the current PWR geometry, with the actual power and burnup of an existing PWR. Assuming a 60 psia pressure drop can be sustained through the fuel bundle, we concluded the following for square channels: the peak achievable power is 5556 MWt for a rod diameter of 6.5 mm and a P/D ratio of 1.43, and the highest power that can be achieved using the existing 12.6 mm pitch and 10.2 mm fuel rods is 4586 MWt. These power levels are significantly higher than the 3800 MWt of the reference PWR. (author)

  4. General layout of a 1300 MW PWR buildings: standard lay-out and influence factors

    International Nuclear Information System (INIS)

    Silva Messias, M. da

    1986-01-01

    The Standardization concept of a 1300 MW Nuclear Power Plant equipped with pressurized-water reactors (PWR) will be considered with regard to the factors which have various degrees of influence on the Layout of the Site. Standardization with regard to the Layout of nuclear power plant, stands, however also for a fixed arrangement of the components in the main buildings and a fixed arrangement of the buildings in the site plan. Standardization may result in simplified and shorter licensing procedures and mean less planning effort. Concentration of systems, optimization of the electro-mechanical design, clear separation of the controlled area, need for shielding, maintenance and safety aspects are some of number of factors which have various degress of influence on the layout of the buildings. (Author) [pt

  5. Comparative study on plutonium and MA recycling in equilibrium burnup and standard burnup of PWR

    International Nuclear Information System (INIS)

    Waris, Abdul; Kurniadi, Rizal; Su'ud, Zaki; Permana, Sidik

    2005-01-01

    The equilibrium burnup model is a powerful method since its can handle all possible generated nuclides in any nuclear system. Moreover, this method is a simple time independent method. Hence the equilibrium burnup method could be very useful for evaluating and forecasting the characteristics of any nuclear fuel cycle, even the strange one, e.g. all nuclides are confined in the reactor. However, this method needs to be verified since the method is not a standard tool. The present study aimed to compare the characteristics of plutonium recycling and plutonium and minor actinides (MA) recycling in PWR with the equilibrium burnup and the standard burnup. In order to become more comprehensive study, an influence of moderator-to-fuel volume ratio (MFR) changes by changing the pin-pitch of fuel cell has been evaluated. The MFR ranges from 0.5 to 4.0. For the equilibrium burnup we used equilibrium cell-burnup code. We have employed 1368 nuclides in the equilibrium calculation with 129 of them are heavy metals (HMs). For standard burnup, SRAC2002 code has been utilized with 26 HMs and 66 fission products (FPs). The JENDL 3.2 library has been employed for both burnup schemes. The uranium, plutonium and MA vector, which resulted from the equilibrium burnup are directly used as fuel input composition for the standard burnup calculation. Both burnup results demonstrate that plutonium recycling and plutonium and MA recycling can be conducted safer in tight lattice core. They are also show the similar trend in neutron spectrum, which become harder with the increasing number of recycled heavy nuclides as well as the decreasing of the MFR values. However, there are some discrepancy on the effective multiplication factor and the conversion ratio, especially for the reactor core for MFR ≥ 2.0. (author)

  6. Sophysticated systems for analysing standard signals of a PWR NPP for diagnostic purposes

    International Nuclear Information System (INIS)

    Por, G.; Adorjan, F.; Czibok, T.; Gloeckler, O.; Makai, M.; Valko, J.

    1986-11-01

    An expert system is presented, which was designed for WWER type nuclear power plants (NPP) with 440 MWe PWR units. The input of the expert system includes the most important technological parameters of the core and of the primary and secondary loops. The expert system consists of the reactor noise diagnostics system (RNDS) and the on-line analysis system (VERONA). RNDS processes the AC components of measured signals. The application of RNDS advanced results in the following fields: registration of base line spectra; identification and localization of in core vibration, core barrel motion, propagating disturbances and the beginning of boiling; estimation of rector parameters; sensor diagnostics. VERONA processes the DC components. The following estimates are displayed: the total power production, the power generation in each fuel assembly and at ten elevations, the heat balance. (author)

  7. Addendum to the procedure of KWU standard calculation for PWR fuel assembly with gadolinium

    International Nuclear Information System (INIS)

    Andrade, E.P. de

    1993-01-01

    The objective of this work is to solve a doubt appeared in the standard procedure of KWU/Siemens for fuel assembly (FA) with gadolinium. In this procedure, the σ's and form functions of such assembly are modified by his effective heterogeneity factor factor (f eff ), which is defined as the ratio between the heterogeneity factors (f het ) of FA's with and without poison. The doubt appeared at the time to calculated the f het of FA without poison: should one consider the pure FA or the FA with poison in which the concentration of gadolinium would be set to zero, but one should keep that of natural uranium? The best results were obtained considering the second hypothesis. (author)

  8. A seismic analysis of Korean standard PWR fuels under transition core conditions

    International Nuclear Information System (INIS)

    Kim, Hyeong Koo; Park, Nam Kyu; Jang, Young Ki; Kim, Jae Ik; Kim, Kyu Tae

    2005-01-01

    The PLUS7 fuel is developed to achieve higher thermal performance, burnup and more safety margin than the conventional fuel used in the Korean Standard Nuclear Plants (KSNPs) and to sustain structural integrity under increased seismic requirement in Korea. In this study, a series of seismic analysis have been performed in order to evaluate the structural integrity of fuel assemblies associated with seismic loads in the KSNPs under transition core conditions replacing the Guardian fuel, which is a resident fuel in the KSNP reactors, with the PLUS7 fuel. For the analysis, transition core seismic models have been developed, based on the possible fuel loading patterns. And the maximum impact forces on the spacer grid and various stresses acting on the fuel components have been evaluated and compared with the through-grid strength of spacer grids and the stress criteria specified in the ASME code for each fuel component, respectively. Then three noticeable parameters regarding as important parameters governing fuel assembly dynamic behavior are evaluated to clarify their effects on the fuel impact and stress response. As a result of the study, it has been confirmed that both the PLUS7 and the Guardian fuel sustain their structural integrity under the transition core condition. And when the damping ratio is constant, increasing the natural frequency of fuel assembly results in a decrease in impact force. The fuel assembly flexural stiffness has an effect increasing the stress of fuel assembly, but not the impact force. And the spacer grid stiffness is directly related with the impact force response. (author)

  9. Comparison between MAAP and ECART predictions of radionuclide transport throughout a French standard PWR reactor coolant system

    International Nuclear Information System (INIS)

    Hervouet, C.; Ranval, W.; Parozzi, F.; Eusebi, M.

    1996-04-01

    In the framework of a collaboration agreement between EDF and ENEL, the MAAP (Modular Accident Analysis Program) and ECART (ENEL Code for Analysis of radionuclide Transport) predictions about the fission product retention inside the reactor cooling system of a French PWR 1300 MW during a small Loss of Coolant Accident were compared. The volatile fission products CsI, CsOH, TeO 2 and the structural materials, all of them released early by the core, are more retained in MAAP than in ECART. On the other hand, the non-volatile fission products, released later, are more retained in ECART than in MAAP, because MAAP does not take into account diffusion-phoresis: in fact, this deposition phenomenon is very significant when the molten core vaporizes the water of the vessel lower plenum. Centrifugal deposition in bends, that can be modeled only with ECART, slightly increases the whole retention in the circuit if it is accounted for. (authors). 18 refs., figs., tabs

  10. Experimental stress analysis and fatigue tests of five 24-in. NPS ANSI Standard B16. 9 tees. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.E.; Hayes, J.K.; Weed, R.A.

    1985-03-01

    Experimental stress analyses and low-cycle fatigue tests of five 24-in. nominal pipe size American National Standards Institute (ANSI) Standard B16.9 forged tees are documented in this report. The tees, designated as Oak Ridge National Laboratory tees T10, T11, T12, T13, and T16, were tested under subcontract at Combustion Engineering, Inc. in Chattanooga, Tennessee. Experimental stress analyses were conducted for 12 individual loadings on each tee. Each test model was instrumented with approx. 225, 1/8-in. three-gage, 45/sup 0/ strain rosettes on the inside and outside surfaces; and 6 linear variable differential transformers mounted on special nonflexible holding frames for measuring deflections and rotations of the pipe extensions. Following completion of the strain-gate tests, each tee was fatigue tested to failure with either a fully reversed displacement controlled in-plane bending moment on the branch or a cyclic internal pressure that ranged from a value slightly above zero to about 90% of the nominal yield pressure of the pipe extensions.

  11. French PWR Safety Philosophy

    International Nuclear Information System (INIS)

    Conte, M. M.

    1986-01-01

    The first 900 MWe units, built under the American Westinghouse licence and with reference to the U. S. regulation, were followed by 28 standardized units, C P1 and C P2 series. Increasing knowledge and lessons learned from starting and operating experience of French nuclear power plants, completed by the experience learned from the operation of foreign reactors, has contributed to the improvement of French PWR design and safety philosophy. As early as 1976, this experience was taken into account by French Safety organisms to discuss, with Electricite de France, the safety options for the planned 1300 MWe units, P4 and P4 series. In 1983, the new reactor scheduled, Ni4 series 1400 MWe, is a totally French design which satisfies the French regulations and other French standards and codes. Based on a deterministic approach, the French safety analysis was progressively completed by a probabilistic approach each of them having possibilities and limits. Increasing knowledge and lessons learned from operating experience have contributed to the French safety philosophy improvement. The methodology now applied to safety evaluation develops a new facet of the in depth defense concept by taking highly unlikely events into consideration, by developing the search of safety consistency of the design, and by completing the deterministic approach by the probabilistic one

  12. Conceptual design of simplified PWR

    International Nuclear Information System (INIS)

    Tabata, Hiroaki

    1996-01-01

    The limited availability for location of nuclear power plant in Japan makes plants with higher power ratings more desirable. Having no intention of constructing medium-sized plants as a next generation standard plant, Japanese utilities are interested in applying passive technologies to large ones. So, Japanese utilities have studied large passive plants based on AP600 and SBWR as alternative future LWRs. In a joint effort to develop a new generation nuclear power plant which is more friendly to operator and maintenance personnel and is economically competitive with alternative sources of power generation, JAPC and Japanese Utilities started the study to modify AP600 and SBWR, in order to accommodate the Japanese requirements. During a six year program up to 1994, basic concepts for 1000 MWe class Simplified PWR (SPWR) and Simplified BWR (SBWR) were developed, though there still remain several areas to be improved. These studies have now stepped into the phase of reducing construction cost and searching for maximum power rating that can be attained by reasonably practical technology. These results also suggest that it is hopeful to develop a large 3-loop passive plant (∼1200 MWe). Since Korea mainly deals with PWR, this paper summarizes SPWR study. The SPWR is jointly studied by JAPC, Japanese PWR Utilities, EdF, WH and Mitsubishi Heavy Industry. Using the AP-600 reference design as a basis, we enlarged the plant size to 3-loops and added engineering features to conform with Japanese practice and Utilities' preference. The SPWR program definitively confirmed the feasibility of a passive plant with an NSSS rating about 1000 MWe and 3 loops. (J.P.N.)

  13. PWR core design calculations

    International Nuclear Information System (INIS)

    Trkov, A.; Ravnik, M.; Zeleznik, N.

    1992-01-01

    Functional description of the programme package Cord-2 for PWR core design calculations is presented. Programme package is briefly described. Use of the package and calculational procedures for typical core design problems are treated. Comparison of main results with experimental values is presented as part of the verification process. (author) [sl

  14. The integrated PWR

    International Nuclear Information System (INIS)

    Gautier, G.M.

    2002-01-01

    This document presents the integrated reactors concepts by a presentation of four reactors: PIUS, SIR, IRIS and CAREM. The core conception, the operating, the safety, the economical aspects and the possible users are detailed. From the performance of the classical integrated PWR, the necessity of new innovative fuels utilization, the research of a simplified design to make easier the safety and the KWh cost decrease, a new integrated reactor is presented: SCAR 600. (A.L.B.)

  15. Nondestructive examination requirements for PWR vessel internals

    International Nuclear Information System (INIS)

    Spanner, J.

    2015-01-01

    This paper describes the requirements for the nondestructive examination of pressurized water reactor (PWR) vessel internals in accordance with the requirements of the EPRI Material Reliability Program (MRP) inspection standard for PWR internals (MRP-228) and the American Society of Mechanical Engineers Section XI In-service Inspection. The MRP vessel internals examinations have been performed at nuclear plants in the USA since 2009. The objective of the inspection standard is to provide the requirements for the nondestructive examination (NDE) methods implemented to support the inspection and evaluation of the internals. The inspection standard contains requirements specific to the inspection methodologies involved as well as requirements for qualification of the NDE procedures, equipment and personnel used to perform the vessel internals inspections. The qualification requirements for the NDE systems will be summarized. Six PWR plants in the USA have completed inspections of their internals using the Inspection and Evaluation Guideline (MRP-227) and the Inspection Standard (MRP-228). Examination results show few instances of service-induced degradation flaws, as expected. The few instances of degradation have mostly occurred in bolting

  16. Reactor control system. PWR

    International Nuclear Information System (INIS)

    2009-01-01

    At present, 23 units of PWR type reactors have been operated in Japan since the start of Mihama Unit 1 operation in 1970 and various improvements have been made to upgrade operability of power stations as well as reliability and safety of power plants. As the share of nuclear power increases, further improvements of operating performance such as load following capability will be requested for power stations with more reliable and safer operation. This article outlined the reactor control system of PWR type reactors and described the control performance of power plants realized with those systems. The PWR control system is characterized that the turbine power is automatic or manually controlled with request of the electric power system and then the nuclear power is followingly controlled with the change of core reactivity. The system mainly consists of reactor automatic control system (control rod control system), pressurizer pressure control system, pressurizer water level control system, steam generator water level control system and turbine bypass control system. (T. Tanaka)

  17. Water chemistry in PWR

    International Nuclear Information System (INIS)

    Abe, Kenji

    1987-01-01

    This article outlines major features and basic concept of the secondary system of PWR's and water properties control measures adopted in recent PWR plants. The secondary system of a PWR consists of a condenser cooling pipe (aluminum-brass, titanium, or stainless steel), low-pressure make-up water heating pipe (aluminum-brass or stainless steel), high-ressure make-up water heating pipe (cupro-nickel or stainless steel), steam generator heat-transfer pipe (Inconel 600 or 690), and bleed/drain pipe (carbon steel, low alloy steel or stainless steel). Other major pipes and equipment are made of carbon steel or stainless steel. Major troubles likely to be caused by water in the secondary system include reduction in wall thickness of the heat-transfer pipe, stress corrosion cracking in the heat-transfer pipe, and denting. All of these are caused by local corrosion due to concentration of purities contained in water. For controlling the water properties in the secondary system, it is necessary to prevent impurities from entering the system, to remove impurities and corrosion products from the system, and to prevent corrosion of apparatus making up the system. Measures widely adopted for controlling the formation of IGA include the addition of boric acid for decreasing the concentration of free alkali and high hydrazine operation for providing a highly reducing atmospere. (Nogami, K.)

  18. PWR decontamination feasibility study

    International Nuclear Information System (INIS)

    Silliman, P.L.

    1978-01-01

    The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of Indian Point 1 are well suited for use in demonstrations

  19. PWR burnable absorber evaluation

    International Nuclear Information System (INIS)

    Cacciapouti, R.J.; Weader, R.J.; Malone, J.P.

    1995-01-01

    The purpose of the study was to evaluate the relative neurotic efficiency and fuel cycle cost benefits of PWR burnable absorbers. Establishment of reference low-leakage equilibrium in-core fuel management plans for 12-, 18- and 24-month cycles. Review of the fuel management impact of the integral fuel burnable absorber (IFBA), erbium and gadolinium. Calculation of the U 3 O 8 , UF 6 , SWU, fuel fabrication, and burnable absorber requirements for the defined fuel management plans. Estimation of fuel cycle costs of each fuel management plan at spot market and long-term market fuel prices. Estimation of the comparative savings of the different burnable absorbers in dollar equivalent per kgU of fabricated fuel. (author)

  20. PWR degraded core analysis

    International Nuclear Information System (INIS)

    Gittus, J.H.

    1982-04-01

    A review is presented of the various phenomena involved in degraded core accidents and the ensuing transport of fission products from the fuel to the primary circuit and the containment. The dominant accident sequences found in the PWR risk studies published to date are briefly described. Then chapters deal with the following topics: the condition and behaviour of water reactor fuel during normal operation and at the commencement of degraded core accidents; the generation of hydrogen from the Zircaloy-steam and the steel-steam reactions; the way in which the core deforms and finally melts following loss of coolant; debris relocation analysis; containment integrity; fission product behaviour during a degraded core accident. (U.K.)

  1. Seismic qualification of PWR plant auxiliary feedwater systems

    International Nuclear Information System (INIS)

    Lu, S.C.; Tsai, N.C.

    1983-08-01

    The NRC Standard Review Plan specifies that the auxiliary feedwater (AFW) system of a pressurized water reactor (PWR) is a safeguard system that functions in the event of a Safe Shutdown Earthquake (SSE) to remove the decay heat via the steam generator. Only recently licensed PWR plants have an AFW system designed to the current Standard Review Plan specifications. The NRC devised the Multiplant Action Plan C-14 in order to make a survey of the seismic capability of the AFW systems of operating PWR plants. The purpose of this survey is to enable the NRC to make decisions regarding the need of requiring the licensees to upgrade the AFW systems to an SSE level of seismic capability. To implement the first phase of the C-14 plan, the NRC issued a Generic Letter (GL) 81-14 to all operating PWR licensees requesting information on the seismic capability of their AFW systems. This report summarizes Lawrence Livermore National Laboratory's efforts to assist the NRC in evaluating the status of seismic qualification of the AFW systems in 40 PWR plants, by reviewing the licensees' responses to GL 81-14

  2. Evolution in the process of searching PWR recharges schemes. New necessity and standards; Evolucion en el proceso de busqueda de esquema de recarga. Nuevas necesidades y criterios

    Energy Technology Data Exchange (ETDEWEB)

    Millan, M. J.

    2010-07-01

    The search and selection process of the scheme has evolved to answer the new Nuclear Power Plants and market necessity: new standards and restrictions have to been considered and increase the importance of the interfaces; both as between different design areas, as between the designer and the client.

  3. Sizewell 'B' PWR reference design

    International Nuclear Information System (INIS)

    1982-04-01

    The reference design for a PWR power station to be constructed as Sizewell 'B' is presented in 3 volumes containing 14 chapters and in a volume of drawings. The report describes the proposed design and provides the basis upon which the safety case and the Pre-Construction Safety Report have been prepared. The station is based on a 3425MWt Westinghouse PWR providing steam to two turbine generators each of 600 MW. The layout and many of the systems are based on the SNUPPS design for Callaway which has been chosen as the US reference plant for the project. (U.K.)

  4. Parameterized representation of macroscopic cross section for PWR reactor

    International Nuclear Information System (INIS)

    Fiel, João Cláudio Batista; Carvalho da Silva, Fernando; Senra Martinez, Aquilino; Leal, Luiz C.

    2015-01-01

    Highlights: • This work describes a parameterized representation of the homogenized macroscopic cross section for PWR reactor. • Parameterization enables a quick determination of problem-dependent cross-sections to be used in few group calculations. • This work allows generating group cross-section data to perform PWR core calculations without computer code calculations. - Abstract: The purpose of this work is to describe, by means of Chebyshev polynomials, a parameterized representation of the homogenized macroscopic cross section for PWR fuel element as a function of soluble boron concentration, moderator temperature, fuel temperature, moderator density and 235 92 U enrichment. The cross-section data analyzed are fission, scattering, total, transport, absorption and capture. The parameterization enables a quick and easy determination of problem-dependent cross-sections to be used in few group calculations. The methodology presented in this paper will allow generation of group cross-section data from stored polynomials to perform PWR core calculations without the need to generate them based on computer code calculations using standard steps. The results obtained by the proposed methodology when compared with results from the SCALE code calculations show very good agreement

  5. VHTR, ADS, and PWR spent nuclear fuel analysis

    Energy Technology Data Exchange (ETDEWEB)

    Salome, J.A.D.; Cardoso, F.; Velasquez, C.E.; Pereira, F.; Pereira, C. [Departamento de Engenharia Nuclear - Escola de Engenharia Universidade Federal de Minas Gerais, Av. Antonio Carlos, 6627, Pampulha, Belo Horizonte MG, CEP: 31270-901 (Brazil); Instituto Nacional de Ciencias e Tecnologia de Reatores Nucleares Inovadores - CNPq, Rio de Janeiro (Brazil); Barros, G.P. [Comissao Nacional de Energia Nuclear - CNEN, Rua General Severiano 82, Botafogo, Rio de Janeiro, RJ, CEP: 22290-040 (Brazil)

    2016-07-01

    The aim of this study is to analyze and compare the discharged-spent fuel of 3 types of nuclear systems: a Very High-Temperature Gas Reactor (VHTR), a lead-cooled Accelerator-Driven System (ADS) and a standard Pressurized Water Reactor (PWR). The two first systems, VHTR, and ADS were designed to use reprocessed fuels. UREX+ and GANEX techniques were used for the reprocessing processes respectively. The fuel burnup simulated for the systems in other works have been used to obtain the final composition of the spent fuel discharged. After discharge, the radioactivity, the radiotoxicity, and the decay heat were evaluated through the ORIGEN 2.1 code until 10{sup 7} years and compared to the literature. The spent nuclear waste (SNF) coming from reprocessing techniques and burned up in advanced reactors show that the radiotoxicity decreases below a conventional SNF from a typical PWR for the time studied. The VHTR and ADs have higher values of radioactivity, radiotoxicity and decay heat, because of the greater concentrations of plutonium and curium in these reactors than in the PWR. Fission products have the greatest contribution for the first 25 years over the parameters studied for a PWR. The most harmful fission products are: Ba{sup 137m}, Tc{sup 99}, I{sup 129} and Nb{sup 93m} and for actinides is the plutonium and curium.

  6. PWR plant construction in Japan

    International Nuclear Information System (INIS)

    Tamura, Toshifumi

    2002-01-01

    The construction methods based on the experiences on the Nuclear Island, which is a critical path in the total construction schedule, have been studied and reconsidered in order to construct by more reliable and economical method. So various improved construction method are being applied and the duration of construction is being reduced continuously. So various improved construction method are being applied and the duration of construction is being reduced continuously. In this paper, the history of construction of twenty-three (23) PWR Plant, the actual construction methods and schedule of Ohi-3/4, to which the many improved methods were applied during their construction, are introduced mainly with the improved points for previously constructed plants. And also the situation of construction method for the next PWR Plant is simply explained

  7. Overview of PWR chemistry options

    Energy Technology Data Exchange (ETDEWEB)

    Nordmann, F.; Stutzmann, A.; Bretelle, J.L. [Electricite de France, Central Labs. (France)

    2002-07-01

    EDF Central Laboratories, in charge of engineering in chemistry, of defining the chemistry specifications and studying the operation feedback and improvement for 58 PWR units, have the opportunity to evaluate many options of operation developed and applied all around the world. Thanks to these international relationships and to the benefit of a large feedback from many units, some general evaluation of the various options is discussed in this paper. (authors)

  8. Corrosion of PWR steam generators

    International Nuclear Information System (INIS)

    Garnsey, R.

    1979-01-01

    Some designs of pressurized water reactor (PWR) steam generators have experienced a variety of corrosion problems which include stress corrosion cracking, tube thinning, pitting, fatigue, erosion-corrosion and support plate corrosion resulting in 'denting'. Large international research programmes have been mounted to investigate the phenomena. The operational experience is reviewed and mechanisms which have been proposed to explain the corrosion damage are presented. The implications for design development and for boiler and feedwater control are discussed. (author)

  9. PWR system reliability improvement activities

    International Nuclear Information System (INIS)

    Yoshikawa, Yuichiro

    1985-01-01

    In Japan lacking in energy resources, it is our basic energy policy to accelerate the development program of nuclear power, thereby reducing our dependence. As referred to in the foregoing, every effort has been exerted on our part to improve the PWR system reliability by dint of the so-called 'HOMEMADE' TQC activities, which is our brain-child as a result of applying to the energy industry the quality control philosophy developed in the field of manufacturing industry

  10. Validating Westinghouse atom 16 x 16 and 18 x 18 PWR fuel performance

    International Nuclear Information System (INIS)

    Andersson, S.; Gustafson, J.; Jourdain, P.; Lindstroem, L.; Hallstadius, L.; Hofling, C.G.

    2001-01-01

    Westinghouse Atom designs and fabricates PWR fuel for all major European fuel types: 17 x 17 standard (12 ft) and 17 x 17 XL (14 ft) for Westinghouse type PWRs, and 16 x 16 and 18 x 18 fuel for Siemens type PWRs. The W Atom PWR fuel designs are based on the extensive Westinghouse CE PWR fuel experience from combustion engineering type PWRs. The W atom designs utilise basic design features from the W CE fuel tradition, such as all-Zircaloy mid grids and the proven ( 6 rod years) Guardian TM debris catcher, which is integrated in the bottom Inconel grid. Several new features have been developed to meet with stringent European requirements originating from requirements on very high burnup, in combination with low-leakage core operating strategies and high coolant temperatures. The overall reliability of the Westinghouse Atom PWR fuel is very high; no fuel failure has been detected since 1997. (orig.)

  11. Ciclon: A neutronic fuel management program for PWR's consecutive cycles

    International Nuclear Information System (INIS)

    Aragones, J.M.

    1977-01-01

    The program description and user's manual of a new computer code is given. Ciclon performs the neutronic calculation of consecutive reload cycles for PWR's fuel management optimization. Fuel characteristics and burnup data, region or batch sizes, loading schemes and state of previously irradiated fuel are input to the code. Cycle lengths or feed enrichments and burnup sharing for each region or batch are calculate using different core neutronic models and printed or punched in standard fuel management format. (author) [es

  12. Surveillance of vibrations in PWR

    International Nuclear Information System (INIS)

    Espefaelt, R.; Lorenzen, J.; Aakerhielm, F.

    1980-07-01

    The core of a PWR - including fuel elements, internal structure, control rods and core support structure inside the pressure vessel - is subjected to forces which can cause vibrations. One sensitive means to detect and analyse such vibrations is by means of the noise from incore and excore neutron detector signals. In this project noise recordings have been made on two occasions in the Ringhals 2 plant and the obtained data been analysed using the Studsvik Noise Analysis Program System (SNAPS). The results have been intepreted and a detailed description of the vibrational status of the core and pressure vessel internals has been produced. On the basis of the obtained results it is proposed that neutron signal noise analysis should be performed at each PWR plant in the beginning, middle and end of each fuel cycle and an analysis be made using the methods developed in the project. It would also provide a contribution to a higher degree of preparedness for diagnostic tasks in case of unexpected and abnormal events. (author)

  13. Babcock and Wilcox advanced PWR development

    International Nuclear Information System (INIS)

    Kulynych, G.E.; Lemon, J.E.

    1986-01-01

    The Babcock and Wilcox 600 MWe PWR design is discussed. Main features of the new B-600 design are improvements in reactor system configuration, glandless coolant pumps, safety features, core design and steam generators

  14. Alloy development for high burnup cladding (PWR)

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, R. [Kraftwerk Union AG, Mulheim (Germany); Jeong, Y.H.; Baek, K.H.; Kim, S.J.; Choi, B.K.; Kim, J.M. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-04-01

    An overview on current alloy development for high burnup PWR fuel cladding is given. It is mainly based on literature data. First, the reasons for an increase of the current mean discharge burnup from 35 MWd / kg(U) to 70 MWd / kg(U) are outlined. From the material data, it is shown that a batch average burnup of 60-70 MWd / kg(U), as aimed by many fuel vendors, can not be achieved with stand (=ASTM-) Zry-4 cladding tubes without violating accepted design criteria. Specifically criteria which limit maximum oxide scale thickness and maximum hydrogen content, and to a less degree, maximum creep and growth rate, can not be achieved. The development potential of standard Zry-4 is shown. Even when taking advantage of this potential, it is shown that an 'improved' Zry-4 is reaching its limits when it achieves the target burnup. The behavior of some Zr alloys outside the ASTM range is shown, and the advantages and disadvantages of the 3 alloy groups (ZrSn+transition metals, ZrNb, ZrSnNb+transition metals) which are currently considered to have the development potential for high burnup cladding materials are depicted. Finally, conclusions are drawn. (author). 14 refs., 11 tabs., 82 figs.

  15. Alloy development for high burnup cladding (PWR)

    International Nuclear Information System (INIS)

    Hahn, R.; Jeong, Y. H.; Baek, K. H.; Kim, S. J.; Choi, B. K.; Kim, J.M.

    1999-04-01

    An overview on current alloy development for high burnup PWR fuel cladding is given. It is mainly based on literature data. First, the reasons for an increase of the current mean discharge burnup from 35 MWd / kg(U) to 70 MWd / kg(U) are outlined. From the material data, it is shown that a batch average burnup of 60-70 MWd / kg(U), as aimed by many fuel vendors, can not be achieved with stand (=ASTM-) Zry-4 cladding tubes without violating accepted design criteria. Specifically criteria which limit maximum oxide scale thickness and maximum hydrogen content, and to a less degree, maximum creep and growth rate, can not be achieved. The development potential of standard Zry-4 is shown. Even when taking advantage of this potential, it is shown that an 'improved' Zry-4 is reaching its limits when it achieves the target burnup. The behavior of some Zr alloys outside the ASTM range is shown, and the advantages and disadvantages of the 3 alloy groups (ZrSn+transition metals, ZrNb, ZrSnNb+transition metals) which are currently considered to have the development potential for high burnup cladding materials are depicted. Finally, conclusions are drawn. (author). 14 refs., 11 tabs., 82 figs

  16. Minimization of radioactive liquids released from PWR

    International Nuclear Information System (INIS)

    Yoshikawa, Hideo; Kohri, Masaharu.

    1981-01-01

    The quantity of radioactive substances in the liquids released into the environment from a PWR power station in normal operation was determined, following the path from the sources of generation, that is, the equipments in primary and secondary cooling systems, to the release into the environment after the radioactive substances were removed in treatment facilities. The quantity of radioactive substances released from primary and secondary systems was determined for each source of generation in a standard plant, and the results were examined. As the concrete example of reducing the release on the basis of ''As low as reasonably achievable'' concept, the increase of letdown flow rate and the installation of a condensate-desalting column are reported. As the sources of generation, the primary coolant formed by shim bleed and the drain from primary system equipments, the drain from an auxiliary building floor, radiochemistry waste solution and the drain from intermediate cooling system, the waste water of washing and shower bath, the drain from a turbine building floor, and the blow-down waste from steam generators are enumerated. The concentration of radioactive substances in primary and secondary coolants, the decontamination factor of waste treatment equipments and the measures for reducing the release are described. (Kako, I.)

  17. Radiation protection optimization in the PWR type reactor dismantling

    International Nuclear Information System (INIS)

    Hilmoine, R.

    1998-01-01

    The studies made at the international level for the PWR type reactors, give dosimetric evaluations about 10 to 15 h.Sv for an immediate dismantling and around three to four times lower for a delayed dismantling according to the storage time. The technical hypothesis, the ambient dosimetry, the time of occupational exposure and the radioactive wastes management are not clearly specified so, Electricite de France has undertaken a more exhaustive study that takes into account, the radiation protection dimension in its universality from a complete radiological characterization in a standard installation. (N.C.)

  18. Life management plants at nuclear power plants PWR

    International Nuclear Information System (INIS)

    Esteban, G.

    2014-01-01

    Since in 2009 the CSN published the Safety Instruction IS-22 (1) which established the regulatory framework the Spanish nuclear power plants must meet in regard to Life Management, most of Spanish nuclear plants began a process of convergence of their Life Management Plants to practice 10 CFR 54 (2), which is the current standard of Spanish nuclear industry for Ageing Management, either during the design lifetime of the plant, as well as for Long-Term Operation. This article describe how Life Management Plans are being implemented in Spanish PWR NPP. (Author)

  19. Categorization of PWR accident sequences and guidelines for fault trees: seismic initiators

    International Nuclear Information System (INIS)

    Kimura, C.Y.

    1984-09-01

    This study developed a set of dominant accident sequences that could be applied generically to domestic commercial PWRs as a standardized basis for a probabilistic seismic risk assessment. This was accomplished by ranking the Zion 1 accident sequences. The pertinent PWR safety systems were compared on a plant-by-plant basis to determine the applicability of the dominant accident sequences of Zion 1 to other PWR plants. The functional event trees were developed to describe the system functions that must work or not work in order for a certain accident sequence to happen, one for pipe breaks and one for transients

  20. Life management plants at nuclear power plants PWR; Planes de gestion de vida en centrales nucleares PWR

    Energy Technology Data Exchange (ETDEWEB)

    Esteban, G.

    2014-10-01

    Since in 2009 the CSN published the Safety Instruction IS-22 (1) which established the regulatory framework the Spanish nuclear power plants must meet in regard to Life Management, most of Spanish nuclear plants began a process of convergence of their Life Management Plants to practice 10 CFR 54 (2), which is the current standard of Spanish nuclear industry for Ageing Management, either during the design lifetime of the plant, as well as for Long-Term Operation. This article describe how Life Management Plans are being implemented in Spanish PWR NPP. (Author)

  1. Representing Operational Knowledge of PWR Plant by Using Multilevel Flow Modelling

    DEFF Research Database (Denmark)

    Zhang, Xinxin; Lind, Morten; Jørgensen, Sten Bay

    2014-01-01

    situation and support operational decisions. This paper will provide a general MFM model of the primary side in a standard Westinghouse Pressurized Water Reactor ( PWR ) system including sub - systems of Reactor Coolant System, Rod Control System, Chemical and Volume Control System, emergency heat removal...

  2. Upgrading of PWR plant simulators

    International Nuclear Information System (INIS)

    Wada, Tomonori; Sasaki, Kazunori; Nakaishi, Hirokazu.

    1989-01-01

    For the education and training of operators in electric power plants, simulators have been employed, and it is well known that their effect is great. There are operation training simulators which simulate the dynamic characteristics of plants and all the machinery and equipment that operators handle, and train the procedure of restoration at the time of abnormality in plants, education simulators which can analyze the dynamic characteristics of plants efficiently in a short time, and offer information by visualizing phenomena with three-dimensional display and others so as to be easily understandable, and forecast simulators which do the analysis forecasting plant behavior at the time of abnormality in plants, and investigate the necessity of the guide for operation procedure and the countermeasures at the time of emergency. In this explanation, the upgrading of operation training simulators which have been put already in training is discussed. The constitution of simulator system and the instructor function, the outline of PWR plant simulation models comprising thermal flow model, pump model, leak model and so on, the techniques of increasing simulator speed, and the example of analysis using the NUPAC code are reported. (K.I.)

  3. PWR secondary water chemistry study

    International Nuclear Information System (INIS)

    Pearl, W.L.; Sawochka, S.G.

    1977-02-01

    Several types of corrosion damage are currently chronic problems in PWR recirculating steam generators. One probable cause of damage is a local high concentration of an aggressive chemical even though only trace levels are present in feedwater. A wide variety of trace chemicals can find their way into feedwater, depending on the sources of condenser cooling water and the specific feedwater treatment. In February 1975, Nuclear Water and Waste Technology Corporation (NWT), was contracted to characterize secondary system water chemistry at five operating PWRs. Plants were selected to allow effects of cooling water chemistry and operating history on steam generator corrosion to be evaluated. Calvert Cliffs 1, Prairie Island 1 and 2, Surry 2, and Turkey Point 4 were monitored during the program. Results to date in the following areas are summarized: (1) plant chemistry variations during normal operation, transients, and shutdowns; (2) effects of condenser leakage on steam generator chemistry; (3) corrosion product transport during all phases of operation; (4) analytical prediction of chemistry in local areas from bulk water chemistry measurements; and (5) correlation of corrosion damage to chemistry variation

  4. Parallel GPU implementation of PWR reactor burnup

    International Nuclear Information System (INIS)

    Heimlich, A.; Silva, F.C.; Martinez, A.S.

    2016-01-01

    Highlights: • Three GPU algorithms used to evaluate the burn-up in a PWR reactor. • Exhibit speed improvement exceeding 200 times over the sequential. • The C++ container is expansible to accept new nuclides chains. - Abstract: This paper surveys three methods, implemented for multi-core CPU and graphic processor unit (GPU), to evaluate the fuel burn-up in a pressurized light water nuclear reactor (PWR) using the solutions of a large system of coupled ordinary differential equations. The reactor physics simulation of a PWR reactor spends a long execution time with burnup calculations, so performance improvement using GPU can imply in better core design and thus extended fuel life cycle. The results of this study exhibit speed improvement exceeding 200 times over the sequential solver, within 1% accuracy.

  5. PWR Analysis with the Advanced System: DELFOS

    International Nuclear Information System (INIS)

    Cabellos, O.; Aragones, J.M.; Ahnert, C.

    1998-01-01

    The development of new PWR codes is necessary due to the heterogeneity of fuel assemblies, the complexity of load patterns and the required operation conditions. Code revisions have been previously referred. Although modern advanced nodal core models have been well established, some reports in the Annual Conference of the A.N.S. in 1995 indicated that the accuracy of cross section models have received less attention. Due to the new performance and taking into account the importance of the nodal cross-sections approximations, the group of researchers in the Instituto de Fusion Nuclear (UPM)have developed new models (code systems DELFOS) for advanced analysis of PWR cores. The system has been tested in the Asco II NPP, cycle 1 to 11 (nominal operation and startup physics tests) comparing with measurements in the last cycle. In conclusion we have validated this methodology for its general application to PWR reactors. (Author)

  6. ABB advanced BWR and PWR fuel

    International Nuclear Information System (INIS)

    Junkrans, S.; Helmersson, S.; Andersson, S.

    1999-01-01

    Fuel designed and fabricated by ABB is now operating in 40 PWRs and BWRs in Europe, the United States and Korea. An excellent fuel reliability track record has been established. High burnups are proven for both BWR and PWR. Thermal margin improving features and advanced burnable absorber concepts enable the utilities to adopt demanding duty cycles to meet new economic objectives. In particular we note the excellent reliability record of ABB PWR fuel equipped with Guardian TM debris filter, proven to meet the -6 rod-cycles fuel failure goal, and the out-standing operating record of the SVEA 10x10 BWR fuel, where ABB is the only vendor to date with multi batch experience to high burnup. ABB is dedicated to maintain high fuel reliability as well as continually improve and develop a broad line of BWR and PWR products. ABB's development and fuel follow-up activities are performed in close co-operation with its customers. (orig.)

  7. Integral type small PWR with stand-alone safety

    International Nuclear Information System (INIS)

    Makihara, Yoshiaki

    2001-01-01

    A feasibility study is achieved on an integral type small PWR with stand-alone safety. It is designed to have the following features. (1) The coolant does not leak out at any accidental condition. (2) The fuel failure does never occur while it is supposed on the large scale PWR at the design base accident. (3) At any accidental condition the safety is secured without any support from the outside (stand-alone safety secure). (4) It has self-regulating characteristics and easy controllability. The above features can be satisfied by integrate the steam generator and CRDM in the reactor vessel while the pipe line break has to be considered on the conventional PWR. Several counter measures are planned to satisfy the above features. The economy feature is also attained by several simplifications such as (1) elimination of main coolant piping and pressurizer by the integration of primary cooling system and self-pressurizing, (2) elimination of RCP by application of natural circulating system, (3) elimination of ECCS and accumulator by application of static safety system, (4) large scale volume reduction of the container vessel by application of integrated primary cooling system, (5) elimination of boric acid treatment by deletion of chemical shim. The long operation period such as 10 years can be attained by the application of Gd fuel in one batch refueling. The construction period can be shortened by the standardizing the design and the introduction of modular component system. Furthermore the applicability of the reduced modulation core is also considered. (K. Tsuchihashi)

  8. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  9. Improvement of PWR reliability by corrosion prevention

    International Nuclear Information System (INIS)

    Takamatsu, Hiroshi

    1999-01-01

    Since first PWR in Japan started commercial operation in 1970, we have encountered the various modes of corrosion on primary and secondary side components. We have paid much efforts for resolving these corrosion problems, that is, investigating the causes of corrosion and establishing the countermeasures for these corrosion. We summarize these efforts in this article. (author)

  10. Thermohydraulic calculations of PWR primary circuits

    International Nuclear Information System (INIS)

    Botelho, D.A.

    1984-01-01

    Some mathematical and numerical models from Retran computer codes aiming to simulate reactor transients, are presented. The equations used for calculating one-dimensional flow are integrated using mathematical methods from Flash code, with steam code to correlate the variables from thermodynamic state. The algorithm obtained was used for calculating a PWR reactor. (E.G.) [pt

  11. 3D graphics simulation of the PWR

    International Nuclear Information System (INIS)

    Lei Gongchao; Ma Baiyong

    1999-01-01

    Using the functions of the software 'I-DEAS Master Series 5', such as the mode of design, drafting, simulation, test, geometry and so on, the task of stereo graphics simulating the PWR is done. Reliability of designed data is checked

  12. PWR reactors for BBR nuclear power plants

    International Nuclear Information System (INIS)

    Structure and functioning of the nuclear steam generator system developed by BBR and its components are described. Auxiliary systems, control and load following behaviour and fuel management are discussed and the main data of PWR given. The brochure closes with a perspective of the future of the Muelheim-Kaerlich nuclear power plant. (GL) [de

  13. Secondary systems of PWR and BWR

    International Nuclear Information System (INIS)

    Schindler, N.

    1981-01-01

    The secondary systems of a nuclear power plant comprises the steam, condensate and feedwater cycle, the steam plant auxiliary or ancillary systems and the cooling water systems. The presentation gives a general review about the main systems which show a high similarity of PWR and BWR plants. (orig./RW)

  14. Manufacturing technologies of PWR pressure vessels

    International Nuclear Information System (INIS)

    Qin Xubin

    1991-01-01

    Pressure vessels belong to the main component of PWR plants. Starting with describing the manufacture of pressure vessel components and their assembly, the manufacturing technologies of pressure vessels are briefly presented with regards to welding, heat treatment, inspections and testing. In addition, quality assurance during the manufacture is presented with emphasis

  15. Utilization of thorium in PWR type reactors

    International Nuclear Information System (INIS)

    Correa, F.

    1977-01-01

    Uranium 235 consumption is comparatively evaluated with thorium cycle for a PWR type reactor. Modifications are only made in fuels components. U-235 consumption is pratically unchanged in both cycles. Some good results are promised to the mixed U-238/Th-232 fuel cycle in 1/1 proportion [pt

  16. Progress of PWR reactor fuels: OSIRIS equipments

    International Nuclear Information System (INIS)

    Colomez, G.; Farny, G.; Vidal, H.

    1981-09-01

    The experimental reactor Osiris situated at the Saclay Nuclear Centre is a reactor fitted with tests and monitoring facilities. Of the pool and open core type, it can test the test fuel of PWR power stations under high neutron flux. The characteristic stresses of the operating states of power reactors can be reproduced in experimental devices suited to the various study subjects, be this the creep and deformation of zircaloy claddings, the behavior of fuel rods to power ramps, to load following, to remote regulation, to the cooling state in double phase or just analytical tests. The experimental irradiation devices extend from the single static coolant capsule, such as the NaK alloy, to the dynamic coolant test loop that operates in the cooling conditions representative of PWR's including water chemistry. Ancillary devices make it possible to carry out examinations and non-destructive testing: immersed neutron radiography, gamma scanning visualization monitoring device, eddy currents, profilometering [fr

  17. Optimization of reload core design for PWR

    International Nuclear Information System (INIS)

    Shen Wei; Xie Zhongsheng; Yin Banghua

    1995-01-01

    A direct efficient optimization technique has been effected for automatically optimizing the reload of PWR. The objective functions include: maximization of end-of-cycle (EOC) reactivity and maximization of average discharge burnup. The fuel loading optimization and burnable poison (BP) optimization are separated into two stages by using Haling principle. In the first stage, the optimum fuel reloading pattern without BP is determined by the linear programming method using enrichments as control variable, while in the second stage the optimum BP allocation is determined by the flexible tolerance method using the number of BP rods as control variable. A practical and efficient PWR reloading optimization program based on above theory has been encoded and successfully applied to Qinshan Nuclear Power Plant (QNP) cycle 2 reloading design

  18. Fuel management optimization for a PWR

    International Nuclear Information System (INIS)

    Dumas, M.; Robeau, D.

    1981-04-01

    This study is aimed to optimize the refueling pattern of a PWR. Two methods are developed, they are based on a linearized form of the optimization problem. The first method determines a feasible solution in two steps; in the first one the original problem is replaced by a relaxed one which is solved by the Method of Approximation Programming. The second step is based on the Branch and Bound method to find the feasible solution closest to the solution obtained in the first step. The second method starts from a given refueling pattern and tries to improve this pattern by the calculation of the effects of 2 by 2, 3 by 3 and 4 by 4 permutations on the objective function. Numerical results are given for a typical PWR refueling using the two methods

  19. Horizontal Drop of 21- PWR Waste Package

    International Nuclear Information System (INIS)

    A.K. Scheider

    2001-01-01

    The objective of this calculation is to determine the structural response of the waste package (WP) dropped horizontally from a specified height. The WP used for that purpose is the 21-Pressurized Water Reactor (PWR) WP. The scope of this document is limited to reporting the calculation results in terms of stress intensities. The information provided by the sketches (Attachment I) is that of the potential design of the type of WP considered in this calculation, and all obtained results are valid for that design only. This calculation is associated with the WP design and was performed by the Waste Package Design group in accordance with the ''Technical Work Plan for: Waste Package Design Description for LA'' (Ref. 16). AP-3.12Q, ''Calculations'' (Ref. 11) is used to perform the calculation and develop the document. The sketches attached to this calculation provide the potential dimensions and materials for the 21-PWR WP design

  20. Sensitivity analysis of a PWR pressurizer

    International Nuclear Information System (INIS)

    Bruel, Renata Nunes

    1997-01-01

    A sensitivity analysis relative to the parameters and modelling of the physical process in a PWR pressurizer has been performed. The sensitivity analysis was developed by implementing the key parameters and theoretical model lings which generated a comprehensive matrix of influences of each changes analysed. The major influences that have been observed were the flashing phenomenon and the steam condensation on the spray drops. The present analysis is also applicable to the several theoretical and experimental areas. (author)

  1. EDF/CIDEN - ONECTRA: PWR decontamination

    International Nuclear Information System (INIS)

    Fayolle, P.; Orcel, H.; Wertz, L.

    2010-01-01

    In the context of PWR circuit renewal (expected in 2011) and their decontamination, an analysis of data coming from cartography and on site decontamination measurements as well as from premise modelling by means of the PANTHERE radioprotection code, is presented. Several French PWRs have been studied. After a presentation of code principles and operation, the authors discuss the radiological context of a workstation, and give an assessment of the annual dose associated with maintenance operations with or without decontamination

  2. GAIA: AREVAs New PWR fuel assembly design

    Energy Technology Data Exchange (ETDEWEB)

    Vollmert, N.; Gentet, G.; Louf, P.H.; Mindt, M.; O' Brian, J.; Peucker, J.

    2015-07-01

    GAIA is the label of a new PWR Fuel Assembly design developed by AREVA with the objective to provide its customers an advanced fuel assembly design regarding both robustness and performance. Since 2012 GAIA lead fuel assemblies are under irradiation in a Swedish reactor and since 2015 in a U.S. reactor. Visual inspections and examinations carried out so far during the outages confirmed the intended reliability, robustness and the performance enhancement of the design. (Author)

  3. The Conceptual Design of Innovative Safe PWR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-Gon [Centural Research Institute, Daejeon (Korea, Republic of); Heo, Sun [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2016-10-15

    Most of countries operating NPPs have been performed post-Fukushima improvements as short-term countermeasure to enhance the safety of operating NPPs. Separately, vendors have made efforts on developing passive safety systems as long-term and ultimate countermeasures. AP1000 designed by Westinghouse Electric Company has passive safety systems including the passive emergency core cooling system (PECCS), the passive residual heat removal system (PRHRS), and the passive containment cooling system (PCCS). ESBWR designed by GE-Hitachi also has passive safety systems consisting of the isolation condenser system, the gravity driven cooling system and the PCCS. Other countries including China and Russia have made efforts on developing passive safety systems for enhancing the safety of their plants. In this paper, we summarize the design goals and main design feature of innovative safe PWR, iPOWER which is standing for Innovative Passive Optimized World-wide Economical Reactor, and show the developing status and results of research projects. To mitigate an accident without electric power and enhance the safety level of PWR, the conceptual designs of passive safety system and innovative safe PWR have been performed. It includes the PECCS for core cooling and the PCCS for containment cooling. Now we are performing the small scale and separate effect tests for the PECCS and the PCCS and preparing the integral effect test for the PECCS and real scale test for the PCCS.

  4. The historical place of the PWR in energy supply

    International Nuclear Information System (INIS)

    Rippon, S.

    1982-01-01

    The development of nuclear power and evolutionary changes in PWR technology including plant standardisation are discussed. The proposed Sizewell B nuclear power station would benefit from three sources of standardisation: the architect engineering advice of Bechtel; the licensing package of Westinghouse; and the joint design of the SNUPPS group. Safety issues and PWR performance are also discussed. (U.K.)

  5. Advanced PWR fuel design concepts

    International Nuclear Information System (INIS)

    Andersor, C.K.; Harris, R.P.; Crump, M.W.; Fuhrman, N.

    1987-01-01

    For nearly 15 years, Combustion Engineering has provided pressurized water reactor fuel with the features most suppliers are now introducing in their advanced fuel designs. Zircaloy grids, removable upper end fittings, large fission gas plenum, high burnup, integral burnable poisons and sophisticated analytical methods are all features of C-E standard fuel which have been well proven by reactor performance. C-E's next generation fuel for pressurized water reactors features 24-month operating cycles, optimal lattice burnable poisons, increased resistance to common industry fuel rod failure mechanisms, and hardware and methodology for operating margin improvements. Application of these various improvements offer continued improvement in fuel cycle economics, plant operation and maintenance. (author)

  6. Eddy current NDT: a suitable tool to measure oxide layer thickness in PWR fuel rods

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, Donizete A.; Silva Junior, Silverio F. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)], e-mail: daa@cdtn.br, e-mail: silvasf@cdtn.br; Vieira, Andre L.P.S. [Industrias Nucleares do Brasil (INB S.A.), Resende, RJ (Brazil). Fabrica de Combustivel Nuclear], e-mail: andre@inb.gov.br; Soares, Adolpho [Technotest Consultoria e Acessoria Ltda., Belo Horizonte, MG (Brazil)], e-mail: adolpho@technotest.com.br

    2009-07-01

    Eddy current is a nondestructive test (NDT) widely used in industry to support integrity analysis of components and equipment. In the nuclear area it is frequently applied to inspect tubes installed in tube exchangers, such as steam generators and condensers in PWR plants, as well as turbine blades. Adequately assisted by means of robotic devices, that inspection method has been pointed as a suitable tool to perform accurate oxide layer thickness measurements in PWR fuel rods. This paper shows some theoretical aspects and physical operating principles of the inspection method, as well as test probes construction details, and the calibration reference standards fabrication processes. Furthermore, some data, experimentally obtained at INB laboratories and other technical information obtained from TECNATOM S.A. are presented, showing the accuracy and efficacy of such NDT method. (author)

  7. Eddy current NDT: a suitable tool to measure oxide layer thickness in PWR fuel rods

    International Nuclear Information System (INIS)

    Alencar, Donizete A.; Silva Junior, Silverio F.; Vieira, Andre L.P.S.

    2009-01-01

    Eddy current is a nondestructive test (NDT) widely used in industry to support integrity analysis of components and equipment. In the nuclear area it is frequently applied to inspect tubes installed in tube exchangers, such as steam generators and condensers in PWR plants, as well as turbine blades. Adequately assisted by means of robotic devices, that inspection method has been pointed as a suitable tool to perform accurate oxide layer thickness measurements in PWR fuel rods. This paper shows some theoretical aspects and physical operating principles of the inspection method, as well as test probes construction details, and the calibration reference standards fabrication processes. Furthermore, some data, experimentally obtained at INB laboratories and other technical information obtained from TECNATOM S.A. are presented, showing the accuracy and efficacy of such NDT method. (author)

  8. Minimization of PWR reactor control rods wear

    International Nuclear Information System (INIS)

    Ponzoni Filho, Pedro; Moura Angelkorte, Gunther de

    1995-01-01

    The Rod Cluster Control Assemblies (RCCA's) of Pressurized Water Reactors (PWR's) have experienced a continuously wall cladding wear when Reactor Coolant Pumps (RCP's) are running. Fretting wear is a result of vibrational contact between RCCA rodlets and the guide cards which provide lateral support for the rodlets when RCCA's are withdrawn from the core. A procedure is developed to minimize the rodlets wear, by the shuffling and axial reposition of RCCA's every operating cycle. These shuffling and repositions are based on measurement of the rodlet cladding thickness of all RCCA's. (author). 3 refs, 2 figs, 2 tabs

  9. Recent development in PWR zinc injection

    International Nuclear Information System (INIS)

    Ocken, H.; Fruzzetti, K.; Frattini, P.; Wood, C.J.

    2002-01-01

    Zinc injection to the reactor coolant system (RCS) of PWRs holds the promise to alleviate two key challenges facing PWR plant operators: (1) reducing degradation of coolant system materials, including nickel-base alloy tubing and lower alloy penetrations due to stress corrosion cracking, and (2) lowering shutdown dose rates. Primary water stress corrosion cracking (PWSCC) is a dominant tube failure mode at many plants. This paper summarizes recent observations from U. S. and international PWRs that have implemented zinc injection, focusing primarily on coolant chemistry and dose rate issues. It also provides a look at the future direction of EPRI-sponsored projects on this topic. (authors)

  10. Industrywide survey of PWR organics. Final report

    International Nuclear Information System (INIS)

    Richards, J.E.; Byers, W.A.

    1986-07-01

    Thirteen Pressurized Water reactor (PWR) secondary cycles were sampled for organic acids, total organic carbon, and inorganic anions. The distribution and removal of organics in a makeup water treatment system were investigted at an additional plant. TOC analyses were used for the analysis of makeup water systems; anion ion chromatography and ion exclusion chromatography were used for the analysis of secondary water systems. Additional information on plant operation and water chemistry was collected in a survey. The analytical and survey data were compared and correlations made

  11. Technical specifications for PWR secondary water chemistry

    International Nuclear Information System (INIS)

    Weeks, J.R.; van Rooyen, D.

    1977-08-01

    The bases for establishing Technical Specifications for PWR secondary water chemistry are reviewed. Whereas extremely stringent control of secondary water needs to be maintained to prevent denting in some units, sound bases for establishing limits that will prevent stress corrosion, wastage, and denting do not exist at the present time. This area is being examined very thoroughly by industry-sponsored research programs. Based on the evidence available to date, short term control limits are suggested; establishment of these or other limits as Technical Specifications is not recommended until the results of the research programs have been obtained and evaluated

  12. Fuel cycle cost projections. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Clark, L.L.; Chockie, A.D.

    1979-12-01

    This report estimates current and future costs associated with the light water reactor nuclear fuel cycle for both once-through and thermal recycle cases. Using a range of future nuclear power generating scenarios, process flows are developed for each segment of the nuclear fuel cycle. Capital and operating costs are estimated and are combined with the process flows to generate unit cost projections for each fuel cycle segment. The unit costs and process flows are combined in the NUCOST program to estimate fuel cycle power costs through the year 2020. The unit costs are also used to estimate the fuel costs of an individual model PWR and BWR.

  13. Minor actinide transmutation on PWR burnable poison rods

    International Nuclear Information System (INIS)

    Hu, Wenchao; Liu, Bin; Ouyang, Xiaoping; Tu, Jing; Liu, Fang; Huang, Liming; Fu, Juan; Meng, Haiyan

    2015-01-01

    Highlights: • Key issues associated with MA transmutation are the appropriate loading pattern. • Commercial PWRs are the only choice to transmute MAs in large scale currently. • Considerable amount of MA can be loaded to PWR without disturbing k eff markedly. • Loading MA to PWR burnable poison rods for transmutation is an optimal loading pattern. - Abstract: Minor actinides are the primary contributors to long term radiotoxicity in spent fuel. The majority of commercial reactors in operation in the world are PWRs, so to study the minor actinide transmutation characteristics in the PWRs and ultimately realize the successful minor actinide transmutation in PWRs are crucial problem in the area of the nuclear waste disposal. The key issues associated with the minor actinide transmutation are the appropriate loading patterns when introducing minor actinides to the PWR core. We study two different minor actinide transmutation materials loading patterns on the PWR burnable poison rods, one is to coat a thin layer of minor actinide in the water gap between the zircaloy cladding and the stainless steel which is filled with water, another one is that minor actinides substitute for burnable poison directly within burnable poison rods. Simulation calculation indicates that the two loading patterns can load approximately equivalent to 5–6 PWR annual minor actinide yields without disturbing the PWR k eff markedly. The PWR k eff can return criticality again by slightly reducing the boric acid concentration in the coolant of PWR or removing some burnable poison rods without coating the minor actinide transmutation materials from PWR core. In other words, loading minor actinide transmutation material to PWR does not consume extra neutron, minor actinide just consumes the neutrons which absorbed by the removed control poisons. Both minor actinide loading patterns are technically feasible; most importantly do not need to modify the configuration of the PWR core and

  14. CECP, Decommissioning Costs for PWR and BWR

    International Nuclear Information System (INIS)

    Bierschbach, M.C.

    1997-01-01

    1 - Description of program or function: The Cost Estimating Computer Program CECP, designed for use on an IBM personal computer or equivalent, was developed for estimating the cost of decommissioning boiling water reactor (BWR) and light-water reactor (PWR) power stations to the point of license termination. 2 - Method of solution: Cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial volume and costs; and manpower staffing costs. Using equipment and consumables costs and inventory data supplied by the user, CECP calculates unit cost factors and then combines these factors with transportation and burial cost algorithms to produce a complete report of decommissioning costs. In addition to costs, CECP also calculates person-hours, crew-hours, and exposure person-hours associated with decommissioning. 3 - Restrictions on the complexity of the problem: The program is designed for a specific waste charge structure. The waste cost data structure cannot handle intermediate waste handlers or changes in the charge rate structures. The decommissioning of a reactor can be divided into 5 periods. 200 different items for special equipment costs are possible. The maximum amount for each special equipment item is 99,999,999$. You can support data for 10 buildings, 100 components each; ESTS1071/01: There are 65 components for 28 systems available to specify the contaminated systems costs (BWR). ESTS1071/02: There are 75 components for 25 systems available to specify the contaminated systems costs (PWR)

  15. Modeling of PWR fuel at extended burnup

    International Nuclear Information System (INIS)

    Dias, Raphael Mejias

    2016-01-01

    This work studies the modifications implemented over successive versions in the empirical models of the computer program FRAPCON used to simulate the steady state irradiation performance of Pressurized Water Reactor (PWR) fuel rods under high burnup condition. In the study, the empirical models present in FRAPCON official documentation were analyzed. A literature study was conducted on the effects of high burnup in nuclear fuels and to improve the understanding of the models used by FRAPCON program in these conditions. A steady state fuel performance analysis was conducted for a typical PWR fuel rod using FRAPCON program versions 3.3, 3.4, and 3.5. The results presented by the different versions of the program were compared in order to verify the impact of model changes in the output parameters of the program. It was observed that the changes brought significant differences in the results of the fuel rod thermal and mechanical parameters, especially when they evolved from FRAPCON-3.3 version to FRAPCON-3.5 version. Lower temperatures, lower cladding stress and strain, lower cladding oxide layer thickness were obtained in the fuel rod analyzed with the FRAPCON-3.5 version. (author)

  16. PWR and WWER fuel performance. A comparison of major characteristics

    International Nuclear Information System (INIS)

    Weidinger, H.

    2006-01-01

    PWR and WWER fuel technologies have the same basic performance targets: most effective use of the energy stored in the fuel and highest possible reliability. Both fuel technologies use basically the same strategies to reach these targets: 1) Optimized reload strategies; 2) Maximal use of structural material with low neutron cross sections; 3) Decrease the fuel failure frequency towards a 'zero failure' performance by understanding and eliminating the root causes of those defects. The key driving force of the technology of both, PWR and WWER fuel is high burn-up. Presently a range of 45 - 50 MWD/kgU have been reached commercially for PWR and WWER fuel. The main technical limitations to reach high burn-up are typically different for PWR and WWER fuel: for PWR fuel it is the corrosion and hydrogen uptake of the Zr-based materials; for WWER fuel it is the mechanical and dimensional stability of the FA (and the whole core). Corrosion and hydrogen uptake of Zr-materials is a 'non-problem' for WWER fuel. Other performance criteria that are important for high burn-up are the creep and growth behaviour of the Zr materials and the fission gas release in the fuel rod. There exists a good and broad data base to model and design both fuel types. FA and fuel rod vibration appears to be a generic problem for both fuel types but with more evidence for PWR fuel performance reliability. Grid-to-rod fretting is still a major issue in the fuel failure statistics of PWR fuel. Fuel rod cladding defects by debris fretting is no longer a key problem for PWR fuel, while it still appears to be a significant root cause for WWER fuel failures. 'Zero defect' fuel performance is achievable with a high probability, as statistics for US PWR and WWER-1000 fuel has shown

  17. A highly heterogeneous 3D PWR core benchmark: deterministic and Monte Carlo method comparison

    Science.gov (United States)

    Jaboulay, J.-C.; Damian, F.; Douce, S.; Lopez, F.; Guenaut, C.; Aggery, A.; Poinot-Salanon, C.

    2014-06-01

    Physical analyses of the LWR potential performances with regards to the fuel utilization require an important part of the work dedicated to the validation of the deterministic models used for theses analyses. Advances in both codes and computer technology give the opportunity to perform the validation of these models on complex 3D core configurations closed to the physical situations encountered (both steady-state and transient configurations). In this paper, we used the Monte Carlo Transport code TRIPOLI-4®; to describe a whole 3D large-scale and highly-heterogeneous LWR core. The aim of this study is to validate the deterministic CRONOS2 code to Monte Carlo code TRIPOLI-4®; in a relevant PWR core configuration. As a consequence, a 3D pin by pin model with a consistent number of volumes (4.3 millions) and media (around 23,000) is established to precisely characterize the core at equilibrium cycle, namely using a refined burn-up and moderator density maps. The configuration selected for this analysis is a very heterogeneous PWR high conversion core with fissile (MOX fuel) and fertile zones (depleted uranium). Furthermore, a tight pitch lattice is selcted (to increase conversion of 238U in 239Pu) that leads to harder neutron spectrum compared to standard PWR assembly. In these conditions two main subjects will be discussed: the Monte Carlo variance calculation and the assessment of the diffusion operator with two energy groups for the core calculation.

  18. Secure and effective valve stem sealing in PWR power generating plants

    International Nuclear Information System (INIS)

    Reynolds, J.

    1991-01-01

    The PWR power generating plant combines severe operating conditions with the highest safety requirements, making it one of the most demanding environments for seals. An analysis of the conditions inherent in its operation reveals: an aggressive and radioactive fluid at high temperature and pressure; frequent thermal shocks; and hazards for maintenance personnel in the containment area unless the reactor is shut down. The achievement of today's quality and safety standards owes much to the experience, research and testing carried out by the Electricite de France during its graduation from its first nuclear unit to become the world's most important manager of PWR plants with over 45 now under its control. The number of valves involved in the French nuclear program is in excess of 1,300,000. Knowing what the affect of a leak can be, especially if it necessitates a shutdown of the power station, the need to insure the quality of valve sealing can be appreciated. At the beginning of their nuclear building program, the EdF was finding that valves, representing only 2 percent of the investment in a PWR plant, caused 20% of the unwanted outages and cost 60% of the total of plant maintenance. In this report, the author endeavors to show how this problem was solved by team work and concerted action by the EdF, the valve constructors and seal manufacturer, not forgetting the importance of informing and training the maintenance and repair teams within the power stations themselves

  19. Evaluation model for PWR irradiated fuel

    International Nuclear Information System (INIS)

    Gomes, I.C.

    1983-01-01

    The individual economic value of the plutonium isotopes for the recycle of the PWR reactor is investigated, assuming the existence of an market for this element. Two distinct market situations for the stages of the fuel cycle are analysed: one for the 1972 costs and the other for costs of 1982. Comparisons are made for each of the two market situations concerning enrichment of the U-235 in the uranium fuel that gives the minimum cost in the fuel cycle. The method adopted to establish the individual value of the plutonium isotopes consists on the economical analyses of the plutonium fuel cycle for four different isotopes mixtures refering to the uranium fuel cycle. (Author) [pt

  20. A pressure drop model for PWR grids

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dong Seok; In, Wang Ki; Bang, Je Geon; Jung, Youn Ho; Chun, Tae Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A pressure drop model for the PWR grids with and without mixing device is proposed at single phase based on the fluid mechanistic approach. Total pressure loss is expressed in additive way for form and frictional losses. The general friction factor correlations and form drag coefficients available in the open literatures are used to the model. As the results, the model shows better predictions than the existing ones for the non-mixing grids, and reasonable agreements with the available experimental data for mixing grids. Therefore it is concluded that the proposed model for pressure drop can provide sufficiently good approximation for grid optimization and design calculation in advanced grid development. 7 refs., 3 figs., 3 tabs. (Author)

  1. Stochastic optimization of loading pattern for PWR

    International Nuclear Information System (INIS)

    Smuc, T.; Pevec, D.

    1994-01-01

    The application of stochastic optimization methods in solving in-core fuel management problems is restrained by the need for a large number of proposed solutions loading patterns, if a high quality final solution is wanted. Proposed loading patterns have to be evaluated by core neutronics simulator, which can impose unrealistic computer time requirements. A new loading pattern optimization code Monte Carlo Loading Pattern Search has been developed by coupling the simulated annealing optimization algorithm with a fast one-and-a-half dimensional core depletion simulator. The structure of the optimization method provides more efficient performance and allows the user to empty precious experience in the search process, thus reducing the search space size. Hereinafter, we discuss the characteristics of the method and illustrate them on the results obtained by solving the PWR reload problem. (authors). 7 refs., 1 tab., 1 fig

  2. Full MOX high burn-up PWR

    Energy Technology Data Exchange (ETDEWEB)

    Okubo, Tsutomu; Kugo, Teruhiko; Shimada, Shoichiro; Araya, Fumimasa; Ochiai, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-12-01

    As a part of conceptual investigation on advanced light water reactors for the future, a light water reactor with the high burn-up of 100 GWd/t, the long cycle operation of 3 years and the full MOX core is being studied, aiming at the improvement on economical aspects, the reduction of the spent fuel production, the utilization of Plutonium and so forth. The present report summarizes investigation on PWR-type reactors. The core with the increased moderation of the moderator-to-fuel volume ratio of 2.6 {approx} 3.0 has been proposed be such a core that accomplishes requirements mentioned above. Through the neutronic and the thermo-hydrodynamic evaluation, the performances of the core have been evaluated. Also, the safety designing is underway considering the reactor system with the passive safety features. (author)

  3. Development of gadolinia bearing fuel for PWR

    International Nuclear Information System (INIS)

    Seki, Kazuichiro

    1986-01-01

    In the PWR power plants in Japan, the long-period operation cycle was extended legally to a maximum of 13 months from the conventional about 9 months in fiscal 1980. With this move, as a new type of fuel with burnable-poison-rod function, the development was started of gadolinia-bearing (gadolinium oxide) fuel, gadolinia being contained in the fuel pellets. The basic technology studies were completed in fiscal 1984. Actual irradiation of the fuel in Unit 2 of the Oi Power Station was then started in July 1984, demonstrating validity of the design. Meanwhile, the rapid power-up fest and the fuel center temperature measurement are conducted in an overseas reactor from fiscal 1983. The following are described: functions of the burnable absorber, the need for gadolinia-bearing fuel, experiences with gadolinia-bearing fuel, problems in the design and production of gadolinia-bearing fuel, the development of gadolinia-bearing fuel. (Mori, K.)

  4. Development of advanced PWR steam generator

    International Nuclear Information System (INIS)

    Saito, Itaru; Nakamura, Tomomichi

    1999-01-01

    In response to the increased power of the advanced PWR, it is necessary to develop a steam generator (SG) which has a large capacity with high performance and high reliability as well as being economical to produce. In this paper, the development of the design of a new SG for the advanced PWRs is described and compared with the design of a conventional SG. Moreover, an outline of a seismic verification test for the U-bend tube bundle which includes advanced anti-vibration bars (AVB) which are very important is described. As a result, it was verified that the bundle has sufficient strength and a relatively high attenuation to seismic loads. These results will be reflected in the detailed design of advanced AVBs. (author)

  5. The PWR cores management; La gestion des coeurs REP

    Energy Technology Data Exchange (ETDEWEB)

    Barral, J.C. [Electricite de France (EDF), 75 - Paris (France); Rippert, D. [CEA Cadarache, Departement d' Etudes des Reacteurs, DER, 13 - Saint-Paul-lez-Durance (France); Johner, J. [CEA/Cadarache, Dept. de Recherches sur la Fusion Controlee, DRFC, 13 - Saint-Paul-lez-Durance (France)] [and others

    2000-01-25

    During the meeting of the 25 january 2000, organized by the SFEN, scientists and plant operators in the domain of the PWR debated on the PWR cores management. The five first papers propose general and economic information on the PWR and also the fast neutron reactors chains in the electric power market: statistics on the electric power industry, nuclear plant unit management, the ITER project and the future of the thermonuclear fusion, the treasurer's and chairman's reports. A second part offers more technical papers concerning the PWR cores management: performance and optimization, in service load planning, the cores management in the other countries, impacts on the research and development programs. (A.L.B.)

  6. Deboration in nuclear stations of the PWR type

    International Nuclear Information System (INIS)

    1978-01-01

    Reactivity control in nuclear power stations of the PWR type is realised with boric acid. A method to concentrate boric acid without an evaporator has been studied. A flow-sheet with reverse osmosis is proposed. (author)

  7. Microprobe analysis and scanning electron microscope on PWR fuels

    International Nuclear Information System (INIS)

    Giannetto, B.

    1996-01-01

    In this text we present the apparatus used, in the CEA centers of Saclay and Cadarache, for analysis PWR spent fuels and we give results for Uranium oxide fuels and mixed oxide fuels. 5 figs., 26 photos

  8. Characterization of Factors affecting IASCC of PWR Core Internals

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Woo; Hwang, Seong Sik; Kim, Won Sam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-09-15

    A lot works have been performed on IASCC in BWR. Recent efforts have been devoted to investigate IASCC in PWR, but the mechanism in PWR is not fully understood yet as compared with that in BWR due to a lack of data from laboratories and fields. Therefore it is strongly needed to review and analyse recent researches of IASCC in both BWR and PWR for establishing a proactive management technology for IASCC of core internals in Korean PWRs. This work is aimed to review mainly recent technical reports on IASCC of stainless steels for core internals in PWR. For comparison, the works on IASCC in BWR were also reviewed and briefly introduced in this report.

  9. Model for transient simulation in a PWR steam circuit

    International Nuclear Information System (INIS)

    Mello, L.A. de.

    1982-11-01

    A computer code (SURF) was developed and used to simulate pressure losses along the tubes of the main steam circuit of a PWR nuclear power plant, and the steam flow through relief and safety valves when pressure reactors its thresholds values. A thermodynamic model of turbines (high and low pressure), and its associated components are simulated too. The SURF computer code was coupled to the GEVAP computer code, complementing the simulation of a PWR nuclear power plant main steam circuit. (Author) [pt

  10. GO evaluation of a PWR spray system. Final report

    International Nuclear Information System (INIS)

    Long, W.T.

    1975-08-01

    GO is a reliability analysis methodology developed over the years from 1960 to the present by Kaman Sciences Corporation, Colorado Springs, Colorado. In this report the GO methodology is presented and its application demonstrated by performing a reliability analysis of a conceptual PWR Containment Spray System. Certain numerical results obtained are compared with those of a prior fault tree analysis of the same system as documented in the 11 January 1973 draft report, A Fault Tree Evaluation of a PWR Spray System

  11. Calculations of the neutron environment inside a PWR containment

    International Nuclear Information System (INIS)

    Hopkins, W.C.

    1979-01-01

    Neutron dose rates inside a PWR containment have been calculated using the DOT-DOMINO-MORSE technique. These dose rates are compared to measurements performed by teams from the Health Physics Division of the Oak Ridge National Laboratory and the Lawrence Livermore Laboratory. A simple method for extrapolating neutron dose rates at the top of the refueling pool to other areas in PWR containments is outlined

  12. Maintenance Technology and its Applications for PWR Plants

    International Nuclear Information System (INIS)

    Wachi, E.; Nishitani, J.; Okimura, K.; Tokunaga, H.

    2012-01-01

    Of the 24 PWR plants in Japan, eleven have been operated for more than 30 years. Accordingly, it has become extremely important to take measures against ageing structures and components in order to achieve safe and reliable long term operation of these plants. In this paper, a concept of the ageing countermeasure for PWR in Japan is outlined and then representative technologies related to various maintenance activities are presented. (author)

  13. Thermal-hydraulic study of integrated steam generator in PWR

    International Nuclear Information System (INIS)

    Osakabe, Masahiro

    1989-01-01

    One of the safety aspects of innovative reactor concepts is the integration of steam generators (SGs) into the reactor vessel in the case of the pressurized water reactor (PWR). All of the reactor system components including the pressurizer are within the reactor vessel in the SG integrated PWR. The simple heat transfer code was developed for the parametric study of the integrated SG. The code was compared to the once-through 19-tube SG experiment and the good agreement between the experimental results and the code predictions was obtained. The assessed code was used for the parametric study of the integrated once-through 16 m-straight-tube SG installed in the annular downcomer. The proposed integrated SG as a first attempt has approximately the same tube size and pitch as the present PWR and the SG primary and secondary sides in the present PWR is inverted in the integrated PWR. Based on the study, the reactor vessel size of the SG integrated PWR was calculated. (author)

  14. Mitsubishi PWR nuclear fuel with advanced design features

    Energy Technology Data Exchange (ETDEWEB)

    Kaua Goe, Toshiy Uki; Nuno kawa, Koi Chi [Mitsubishi Heavy Industries, Ltd., Tokyo (Japan)

    2008-10-15

    In the last few decades, the global warming has been a big issue. As the breakthrough in this crisis, advanced operations of the water reactor such as higher burn up, longer cycle, and up rating could be effective ways. From this viewpoint, Mitsubishi Heavy Industries (MHI) has developed the fuel for burn up extension, whose assembly burn-up limit is 55GWd/t(A), with the original and advanced designs such as corrosion resistant cladding material MDA, and supplied to Japanese PWR utilities. On the other hand, MHI intends to supply more advanced fuel assemblies not only to domestic market but to the global market. Actually MHI has submitted the application for standard design certification of USA . Advanced Pressurized Water Reactor on Jan. 2nd 2008. The fuel assembly for US APWR is 17x17 type with active fuel length of 14ft, characterized with three features, to {sup E}nhance Fuel Economy{sup ,} {sup E}nable Flexible Core Operation{sup ,} and to {sup I}mprove Reliability{sup .} MHI has also been conducting development activities for more advanced products, such as 70GWd/t(A) burn up limit fuel with cladding, guide thimble and spacer grid made from M-MDATM alloy that is new material with higher corrosion resistance, such as 12ft and 14ft active length fuel, such as fuel with countermeasure against grid fretting, debris fretting, and IRI. MHI will present its activities and advanced designs.

  15. Qualification tests for PWR control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Yong; Jin, Choon Eon; Choi Suhn [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    It is necessary to perform the qualification test for the magnetic jack type CEDM to show the design compatibility because the CEDM is composed of many mechanical and electrical components complicatedly. ABB-CE performed various qualification tests during the development of the System80 CEDM to which Korea Standard Nuclear Plant (KSNP) CEDM referred. The qualification test for the CEDM is classified into the performance test and the dynamic test. The performance test is to verify operability of the CEDM, and the dynamic test is to find dynamic characteristics and to verify the structural integrity if the CEDM for the seismic accidents. Described in this report are the test requirements, the test facilities and the test methods for the performance and the dynamic qualification tests of the PWR magnetic jack type CEDM. The impacts of the design changes in the Korea Next Generation Reactor (KNGR) on the KSNP CEDM were analyzed to present the necessity for the tests. This report also proposes the facilities to perform the tests in KAERI including reasonable schedule for the tests. Attached to this report is the summary of qualification tests of System 80 CEDM performed by ABB-CE. 20 figs., 16 tabs., 21 refs. (Author) .new.

  16. Tendency of nuclear pumps for PWR primary system

    International Nuclear Information System (INIS)

    Shibata, Takeshi

    1976-01-01

    At present, large PWR power stations of more than 1,000 MW are successively constructed, and the pumps used there have become large. The progress and tendency of the technical development of main pumps in primary system are described. The increase of the capacity of power stations is accomplished by increasing the circulating coolant quantity per loop or the number of loops. Same standard primary coolant pumps are employed in the plants from 500 to 1,100 MW. The type of primary coolant pumps changed from canned type to shaft seal type, and the advantages of the shaft seal type are cheap production cost, high efficiency, and the easy utilization of inertia force. The bearings and shaft seals are thermally insulated from primary coolant. As for auxiliary pumps, reciprocating filling-up pumps and centrifugal high pressure injection pumps are used for 500 MW plants, but only centrifugal pumps are used for both purposes in 800 MW plants, and in 1,100 MW plants, the pumps of both types for separate purposes and centrifugal pumps for combined purposes are installed. Horizontal or vertical pumps of same type are used as containment vessel-spraying pumps and excess heat-eliminating pumps. The type of boric acid pumps changed from canned type to mechanical seal type. (Kako, I.)

  17. Control rod effects with plutonium recycle in a PWR

    International Nuclear Information System (INIS)

    Nash, G.; Muehl, G.J.; Gibson, I.H.

    1979-03-01

    A study has been made on a PWR loaded partly and wholly with plutonium to determine the changes in shutdown margin compared with an enriched uranium core. Lattice calculations are used to generate cell constants for core calculations. Three fuel loadings were considered, all uranium, 30% (approximately) of the assemblies plutonium in natural uranium, and all plutonium. The equilibrium fuel management schemes adopted in each case are based on the standard three cycle equal size batch scheme. Detailed calculations of power and irradiation distributions through the cycles have been carried out to provide a starting point for the control rod worth and requirement calculations. Control rod worths are reduced in a plutonium core because of the harder spectrum and higher fuel absorption cross sections. Furthermore, the control rod requirements for shutdown increase because of the increase in fuel and moderator temperature coefficients. This results in a reduction in shutdown margin. The magnitude of these changes is fully analysed in the report. The significance of these reductions depends on the detail of the safety argument but reductions of these sizes are unlikely to be acceptable. The data provided in this report could be used to give a first estimate of the plutonium loading acceptable given the safety assessment of the normal uranium core. (U.K.)

  18. The application of modern nodal methods to PWR reactor physics analysis

    International Nuclear Information System (INIS)

    Knight, M.P.

    1988-06-01

    The objective of this research is to develop efficient computational procedures for PWR reactor calculations, based on modern nodal methods. The analytic nodal method, which is characterised by the use of exact exponential expansions in transverse-integrated equations, is implemented within an existing finite-difference code. This shows considerable accuracy and efficiency on standard benchmark problems, very much in line with existing experience with nodal methods., Assembly powers can be calculated to within 2.0% with just one mesh per assembly. (author)

  19. SCALE 5.1 Predictions of PWR Spent Nuclear Fuel Isotopic Compositions

    Energy Technology Data Exchange (ETDEWEB)

    Radulescu, Georgeta [ORNL; Gauld, Ian C [ORNL; Ilas, Germina [ORNL

    2010-03-01

    The purpose of this calculation report is to document the comparison to measurement of the isotopic concentrations for pressurized water reactor (PWR) spent nuclear fuel determined with the Standardized Computer Analysis for Licensing Evaluation (SCALE) 5.1 (Ref. ) epletion calculation method. Specifically, the depletion computer code and the cross-section library being evaluated are the twodimensional (2-D) transport and depletion module, TRITON/NEWT,2, 3 and the 44GROUPNDF5 (Ref. 4) cross-section library, respectively, in the SCALE .1 code system.

  20. Modeling chemistry in PWR fuel crud

    International Nuclear Information System (INIS)

    PWR fuel crud arises from deposition of corrosion products in the coolant on clad surfaces in the core. These deposits form a porous layer through which water must pass to provide effective heat transfer from the clad surface. The usual heat transfer mechanism is by wick boiling in which water passing through the porous crud is converted to steam that escapes through steam chimneys in the deposit. This conversion of water into steam within the deposit means that dilute solutions in the bulk coolant become concentrated in the crud and this can lead to precipitation of species such as lithium borates, ZnO and Zn-silicates. Such precipitation processes may lead to problems such as crud induced power shifts (CIPS), formally known as axial off-set anomaly (AOA), or crud induced localised corrosion (CILC) of the clad, that has led to cladding failures. These precipitation processes also hinder heat transfer and can lead to hot spots on the clad surfaces that are potentially damaging. Questions such as what should be the plant limits on Zn, Si, B and Li to prevent such problems, and how should these be controlled during the cycle, are not easy to answer. With several new designs of PWR proposing high power density cores and therefore greater subcooled nucleate boiling, and with existing plants still up-rating their cores, these questions are likely to become more important in the future. It is therefore important to understand the relationship between coolant chemistry (Zn, Si, Li, B levels) and the chemistry within fuel crud. The bulk and crud chemistry are coupled along with the bulk and local heat transfer processes. This coupling of chemistry and heat transfer makes this a particularly difficult problem to investigate theoretically although the authors have previously achieved this using a number of one dimensional heat and mass transfer models. This paper discusses a new approach to this problem using finite element methods to solve the relevant coupled chemistry and

  1. Seawater desalination using reusable type small PWR

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Y. [Institute of Engineering Mechanics and Systems, University of Tsukuba, Tsukuba, Ibaraki (Japan); Minato, A. [Planning Division, Central Research Institute of the Electric Power Industry, Komae-shi, Tokyo (Japan); Shimamura, K. [Nuclear Systems Engineering Department, Nuclear Energy Systems Engineering Center, Mitsubishi Heavy Industries, Ltd., Kanagawa (Japan)]. E-mail: shimamura@atom.hq.mhi.co.jp

    2003-07-01

    Demand for seawater desalination is increasing, especially in regions such as the Middle East and North Africa, where populations are growing at a high annual rate. If such demand is met by fossil fuel energy, the influence on the environment, such as global warming, cannot be disregarded. Since these regions are behind in their preparedness of social capital infrastructure, such as power transfer grids, small reactors are considered to be more suitable for introduction than the large reactors found commonly in developed countries. Therefore, a small reusable PWR with mid-range pressure and temperature services, which does not require on-site refuelling, was devised for seawater desalination. In a small reusable PWR, spent fuel is taken out together with the reactor vessel and refuelled on the exterior fuel exchange base prepared independently. Thus, the safeguards against nuclear proliferation increase at a plant site because the lid of the reactor vessel is never opened at the site, in principle. The reactor vessel will be transported from the plant site to a fuel exchange base under stipulated conditions within a transportation cask after a long (about six years) operation. Since fuel handling facilities at the site become unnecessary through centralisation at a fuel exchange base, initial plant construction costs are reduced. In addition, the reactor vessel is reused until its service life has expired. This examination was based on the marine reactor of the experimental nuclear ship, Mutsu, after it had been applied for land use: at a lowered, midrange pressure and temperature service, in theory. It is possible to produce fresh water through reverse osmosis (RO) membrane pressure-rising seawater by a steam turbine driven pump. Using the method of driving a desalination unit high-pressure pump directly by low-pressure steam generated from the heating reactor, fresh water can be produced efficiently. Furthermore, operating at reduced pressure makes it possible

  2. Comparison of the island model parallel implementation with the serial model of the evolutionary algorithm PBIL applied to a PWR reload optimization

    International Nuclear Information System (INIS)

    Lima, Alan M.M. de; Machado, Marcelo D.; Schirru, Roberto

    2002-01-01

    An increasing number of Evolutionary Algorithms (EA), have been successfully employed in complex functions and combinatorial optimization problems. Among the EA there is 'Population Based Incremental Learning' (PBIL), which is a method that combines the mechanisms of the standard genetic algorithm with competitive learning. PBIL has been an efficient tool in combinatorial optimization problems. The purpose of this work is to introduce a parallelization of the PBIL algorithm to be applied in a PWR nuclear reload optimization problem. Tests were performed with data from cycle 7 of the Angra 1 PWR. Results are compared with the serial PBIL ones. (author)

  3. Conceptual study on advanced PWR system

    International Nuclear Information System (INIS)

    Bae, Yoon Young; Chang, M. H.; Yu, K. J.; Lee, D. J.; Cho, B. H.; Kim, H. Y.; Yoon, J. H.; Lee, Y. J.; Kim, J. P.; Park, C. T.; Seo, J. K.; Kang, H. S.; Kim, J. I.; Kim, Y. W.; Kim, Y. H.

    1997-07-01

    In this study, the adoptable essential technologies and reference design concept of the advanced reactor were developed and related basic experiments were performed. 1) Once-through Helical Steam Generator: a performance analysis computer code for heli-coiled steam generator was developed for thermal sizing of steam generator and determination of thermal-hydraulic parameters. 2) Self-pressurizing pressurizer : a performance analysis computer code for cold pressurizer was developed. 3) Control rod drive mechanism for fine control : type and function were surveyed. 4) CHF in passive PWR condition : development of the prediction model bundle CHF by introducing the correction factor from the data base. 5) Passive cooling concepts for concrete containment systems: development of the PCCS heat transfer coefficient. 6) Steam injector concepts: analysis and experiment were conducted. 7) Fluidic diode concepts : analysis and experiment were conducted. 8) Wet thermal insulator : tests for thin steel layers and assessment of materials. 9) Passive residual heat removal system : a performance analysis computer code for PRHRS was developed and the conformance to EPRI requirement was checked. (author). 18 refs., 55 tabs., 137 figs

  4. Conceptual study on advanced PWR system

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yoon Young; Chang, M. H.; Yu, K. J.; Lee, D. J.; Cho, B. H.; Kim, H. Y.; Yoon, J. H.; Lee, Y. J.; Kim, J. P.; Park, C. T.; Seo, J. K.; Kang, H. S.; Kim, J. I.; Kim, Y. W.; Kim, Y. H.

    1997-07-01

    In this study, the adoptable essential technologies and reference design concept of the advanced reactor were developed and related basic experiments were performed. (1) Once-through Helical Steam Generator: a performance analysis computer code for heli-coiled steam generator was developed for thermal sizing of steam generator and determination of thermal-hydraulic parameters. (2) Self-pressurizing pressurizer : a performance analysis computer code for cold pressurizer was developed. (3) Control rod drive mechanism for fine control : type and function were surveyed. (4) CHF in passive PWR condition : development of the prediction model bundle CHF by introducing the correction factor from the data base. (5) Passive cooling concepts for concrete containment systems: development of the PCCS heat transfer coefficient. (6) Steam injector concepts: analysis and experiment were conducted. (7) Fluidic diode concepts : analysis and experiment were conducted. (8) Wet thermal insulator : tests for thin steel layers and assessment of materials. (9) Passive residual heat removal system : a performance analysis computer code for PRHRS was developed and the conformance to EPRI requirement was checked. (author). 18 refs., 55 tabs., 137 figs.

  5. CORD-2 package for PWR design calculations

    International Nuclear Information System (INIS)

    Trkov, A.; Ravnik, M.

    1994-01-01

    The CORD-2 package is designed to provide a modern, independent calculational tool for reactor core calculations. It provides options that are essential for modeling the advanced features of fuel assemblies. Its development is part of a wider effort to establish country's own expertise in nuclear design and safety analysis. The package provides not only the calculational modules, but also the data management support facilities. It has been implemented on VAX/VMS and on PC/DOS, but extension to other systems is quite straightforward. The main components and the calculational methods are briefly described. The results of the validation programme are presented. They include the comparison of the calculated results with the measured values of ten cycles of the Krsko nuclear power plant and for the IAEA test case Almaraz, with special emphasis on the first cores at hot-zero power conditions. The results of the validation programme shows that CORD-2 is applicable for design level PWR core calculations. (authors). 9 refs., 4 figs., 3 tabs

  6. Method of starting up PWR type reactor

    International Nuclear Information System (INIS)

    Kadokami, Akira; Ueno, Ryuji; Tsuge, Ayao; Onimura, Kichiro; Ochi, Tatsuya.

    1988-01-01

    Purpose: To start-up a PWR type reactor so as to effectively impregnate and concentrate corrosion inhibitors in intergranular corrosive faces. Method: Upon reactor start-up, after transferring from the warm zero output state to thermal power loaded state and injecting corrosion inhibitors, thermal power is returned to zero and, subsequently, increased up to a rated power. By selecting the thermal power upon injecting the corrosion inhibitors to a steam generator body, that is, by selecting a thermal power load that starts to boil in heat conduction tubes, feedwater in the clavis portion can be formed into an appropriate boiling convection and, accordingly, the corrosion inhibitors can be penetrated to the clevis portion at a higher rate and in a greater amount as compared with those under zero power condition. Subsequently, when the thermal power is reduced, a sub-cooled state is attained in the clevis portion, in which steams present in the intergranular corrosion faces in the heat conduction tubes are condensated. As a result, the corrosion inhibitors at high concentration are impregnated into the intergranular corrosive faces to provide excellent effects. (Kamimura, M.)

  7. A PWR Thorium Pin Cell Burnup Benchmark

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Kevan Dean; Zhao, X.; Pilat, E. E; Hejzlar, P.

    2000-05-01

    As part of work to evaluate the potential benefits of using thorium in LWR fuel, a thorium fueled benchmark comparison was made in this study between state-of-the-art codes, MOCUP (MCNP4B + ORIGEN2), and CASMO-4 for burnup calculations. The MOCUP runs were done individually at MIT and INEEL, using the same model but with some differences in techniques and cross section libraries. Eigenvalue and isotope concentrations were compared on a PWR pin cell model up to high burnup. The eigenvalue comparison as a function of burnup is good: the maximum difference is within 2% and the average absolute difference less than 1%. The isotope concentration comparisons are better than a set of MOX fuel benchmarks and comparable to a set of uranium fuel benchmarks reported in the literature. The actinide and fission product data sources used in the MOCUP burnup calculations for a typical thorium fuel are documented. Reasons for code vs code differences are analyzed and discussed.

  8. Analysis of reactivity accidents in PWR'S

    International Nuclear Information System (INIS)

    Camous, F.; Chesnel, A.

    1989-12-01

    This note describes the French strategy which has consisted, firstly, in examining all the accidents presented in the PWR unit safety reports in order to determine for each parameter the impact on accident consequences of varying the parameter considered, secondly in analyzing the provisions taken into account to restrict variation of this parameter to within an acceptable range and thirdly, in checking that the reliability of these provisions is compatible with the potential consequences of transgression of the authorized limits. Taking into consideration violations of technical operating specifications and/or non-observance of operating procedures, equipment failures, and partial or total unavailability of safety systems, these studies have shown that fuel mechanical strength limits can be reached but that the probability of occurrence of the corresponding events places them in the residual risk field and that it must, in fact, be remembered that there is a wide margin between the design basis accidents and accidents resulting in fuel destruction. However, during the coming year, we still have to analyze scenarios dealing with cumulated events or incidents leading to a reactivity accident. This program will be mainly concerned with the impact of the cases examined relating to dilution incidents under normal operating conditions or accident operating conditions

  9. Scaling Analysis for PWR Steam Generator

    International Nuclear Information System (INIS)

    Li, Yuquan; Ye, Zishen

    2011-01-01

    To test the nuclear power plant safety system performance and verify the relative safety analysis code, a widely used approach is to design and construct a scaled model based on a scaling methodology. For a pressurized water reactor (PWR), the SG scaling analysis is important before designing a scale model which is expected to well simulate the system response to the accident. In this work, a review of the transient process in SG during a loss of coolant accident (LOCA) is first presented, and then a brief natural circulation scaling analysis is performed to get the basic SG scaling design rules. The U-tube scaling design shows the scaling will enlarge the thermal center height ratio while keeping the length ratio when the scale model uses a different diameter ratio and the height ratio, which causes distortion in natural circulation simulation. And then, by the heat transfer scaling analysis, a relation between the U-tube diameter ratio and model height ratio is obtained, and it shows the diameter ratio decreases with the decreasing model height ratio. In the end, the SG transition from the heat sink to the heat source is analyzed, and the results show the SG secondary inventory and the total material heat capacity need to be properly scaled to represent the transition correctly

  10. Computer aided information system for a PWR

    International Nuclear Information System (INIS)

    Vaidian, T.A.; Karmakar, G.; Rajagopal, R.; Shankar, V.; Patil, R.K.

    1994-01-01

    The computer aided information system (CAIS) is designed with a view to improve the performance of the operator. CAIS assists the plant operator in an advisory and support role, thereby reducing the workload level and potential human errors. The CAIS as explained here has been designed for a PWR type KLT- 40 used in Floating Nuclear Power Stations (FNPS). However the underlying philosophy evolved in designing the CAIS can be suitably adopted for other type of nuclear power plants too (BWR, PHWR). Operator information is divided into three broad categories: a) continuously available information b) automatically available information and c) on demand information. Two in number touch screens are provided on the main control panel. One is earmarked for continuously available information and the other is dedicated for automatically available information. Both the screens can be used at the operator's discretion for on-demand information. Automatically available information screen overrides the on-demand information screens. In addition to the above, CAIS has the features of event sequence recording, disturbance recording and information documentation. CAIS design ensures that the operator is not overburdened with excess and unnecessary information, but at the same time adequate and well formatted information is available. (author). 5 refs., 4 figs

  11. Conceptual study of advanced PWR core design

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Chang, Moon Hee; Kim, Keung Ku; Joo, Hyung Kuk; Kim, Young Il; Noh, Jae Man; Hwang, Dae Hyun; Kim, Taek Kyum; Yoo, Yon Jong

    1997-09-01

    The purpose of this project is for developing and verifying the core design concepts with enhanced safety and economy, and associated methodologies for core analyses. From the study of the sate-of-art of foreign advanced reactor cores, we developed core concepts such as soluble boron free, high convertible and enhanced safety core loaded semi-tight lattice hexagonal fuel assemblies. To analyze this hexagonal core, we have developed and verified some neutronic and T/H analysis methodologies. HELIOS code was adopted as the assembly code and HEXFEM code was developed for hexagonal core analysis. Based on experimental data in hexagonal lattices and the COBRA-IV-I code, we developed a thermal-hydraulic analysis code for hexagonal lattices. Using the core analysis code systems developed in this project, we designed a 600 MWe core and studied the feasibility of the core concepts. Two additional scopes were performed in this project : study on the operational strategies of soluble boron free core and conceptual design of large scale passive core. By using the axial BP zoning concept and suitable design of control rods, this project showed that it was possible to design a soluble boron free core in 600 MWe PWR. The results of large scale core design showed that passive concepts and daily load follow operation could be practiced. (author). 15 refs., 52 tabs., 101 figs.

  12. Conceptual study of advanced PWR core design

    International Nuclear Information System (INIS)

    Kim, Young Jin; Chang, Moon Hee; Kim, Keung Ku; Joo, Hyung Kuk; Kim, Young Il; Noh, Jae Man; Hwang, Dae Hyun; Kim, Taek Kyum; Yoo, Yon Jong.

    1997-09-01

    The purpose of this project is for developing and verifying the core design concepts with enhanced safety and economy, and associated methodologies for core analyses. From the study of the sate-of-art of foreign advanced reactor cores, we developed core concepts such as soluble boron free, high convertible and enhanced safety core loaded semi-tight lattice hexagonal fuel assemblies. To analyze this hexagonal core, we have developed and verified some neutronic and T/H analysis methodologies. HELIOS code was adopted as the assembly code and HEXFEM code was developed for hexagonal core analysis. Based on experimental data in hexagonal lattices and the COBRA-IV-I code, we developed a thermal-hydraulic analysis code for hexagonal lattices. Using the core analysis code systems developed in this project, we designed a 600 MWe core and studied the feasibility of the core concepts. Two additional scopes were performed in this project : study on the operational strategies of soluble boron free core and conceptual design of large scale passive core. By using the axial BP zoning concept and suitable design of control rods, this project showed that it was possible to design a soluble boron free core in 600 MWe PWR. The results of large scale core design showed that passive concepts and daily load follow operation could be practiced. (author). 15 refs., 52 tabs., 101 figs

  13. ABB PWR fuel design for high burnup

    International Nuclear Information System (INIS)

    Nilsson, S.; Jourdain, P.; Limback, M.; Garde, A.M.

    1998-01-01

    Corrosion, hydriding and irradiation induced growth of a based materials are important factors for the high burnup performance of PWR fuel. ABB has developed a number of Zr based alloys to meet the need for fuel that enables operation to elevated burnups. The materials include composition and processing optimised Zircaloy 4 (OPTIN TM ) and Zircaloy 2 (Zircaloy 2P), as well as advanced Zr based alloys with chemical compositions outside the composition specified for Zircaloy. The advanced alloys are either used as Duplex or as single component claddings. The Duplex claddings have an inner component of Zircaloy and an outer layer of Zr with small additions of alloying elements. ABB has furthermore improved the dimensional stability of the fuel assembly by developing stiffer and more bow resistant guide tubes while debris related fuel failures have been eliminated from ABB fuel by introducing the Guardian TM grid. Intermediate flow mixers that improve the thermal hydraulic performance and the dimensional stability of the fuel has also been developed within ABB. (author)

  14. Evolutionary developments of advanced PWR nuclear fuels and cladding materials

    International Nuclear Information System (INIS)

    Kim, Kyu-Tae

    2013-01-01

    Highlights: • PWR fuel and cladding materials development processes are provided. • Evolution of PWR advanced fuel in U.S.A. and in Korea is described. • Cutting-edge design features against grid-to-rod fretting and debris are explained. • High performance data of advanced grids, debris filters and claddings are given. -- Abstract: The evolutionary developments of advanced PWR fuels and cladding materials are explained with outstanding design features of nuclear fuel assembly components and zirconium-base cladding materials. The advanced PWR fuel and cladding materials development processes are also provided along with verification tests, which can be used as guidelines for newcomers planning to develop an advanced fuel for the first time. The up-to-date advanced fuels with the advanced cladding materials may provide a high level of economic utilization and reliable performance even under current and upcoming aggressive operating conditions. To be specific, nuclear fuel vendors may achieve high fuel burnup capability of between 45,000 and 65,000 MWD/MTU batch average, overpower thermal margin of as much as 15% and longer cycle length up to 24 months on the one hand and fuel failure rates of around 10 −6 on the other hand. However, there is still a need for better understanding of grid-to-rod fretting wear mechanisms leading to major PWR fuel defects in the world and subsequently a driving force for developing innovative spacer grid designs with zero fretting wear-induced fuel failure

  15. The advanced main control console for next japanese PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, A. [Hokkaido Electric Power Co., Inc., Sapporo (Japan); Ito, K. [Mitsubishi Heavy Industries, Ltd., Nuclear Energy Systems Engineering Center, Yokohama (Japan); Yokoyama, M. [Mitsubishi Electric Corporation, Energy and Industrial Systems Center, Kobe (Japan)

    2001-07-01

    The purpose of the improvement of main control room designing in a nuclear power plant is to reduce operators' workload and potential human errors by offering a better working environment where operators can maximize their abilities. In order to satisfy such requirements, the design of main control board applied to Japanese Pressurized Water Reactor (PWR) type nuclear power plant has been continuously modified and improved. the Japanese Pressurized Water Reactor (PWR) Utilities (Electric Power Companies) and Mitsubishi Group have developed an advanced main control board (console) reflecting on the study of human factors, as well as using a state of the art electronics technology. In this report, we would like to introduce the configuration and features of the Advanced Main Control Console for the practical application to the next generation PWR type nuclear power plants including TOMARI No.3 Unit of Hokkaido Electric Power Co., Inc. (author)

  16. Pressurizer and steam-generator behavior under PWR transient conditions

    International Nuclear Information System (INIS)

    Wahba, A.B.; Berta, V.T.; Pointner, W.

    1983-01-01

    Experiments have been conducted in the Loss-of-Fluid Test (LOFT) pressurized water reactor (PWR), at the Idaho National Engineering Laboratory, in which transient phenomena arising from accident events with and without reactor scram were studied. The main purpose of the LOFT facility is to provide data for the development of computer codes for PWR transient analyses. Significant thermal-hydraulic differences have been observed between the measured and calculated results for those transients in which the pressurizer and steam generator strongly influence the dominant transient phenomena. Pressurizer and steam generator phenomena that occurred during four specific PWR transients in the LOFT facility are discussed. Two transients were accompanied by pressurizer inflow and a reduction of the heat transfer in the steam generator to a very small value. The other two transients were accompanied by pressurizer outflow while the steam generator behavior was controlled

  17. Improved emergency elevated air release for simplified PWR

    International Nuclear Information System (INIS)

    Naitoh, T.; Bruce, R.A.; Hirota, K.; Tajiri, Y.

    1992-01-01

    In developing the application of the simplified PWR in Japan, one of the most important areas is to limit post-accident site boundary whole body dose. In addressing this, the concept of Emergency Passive Air Filtration System (EPAFS) and it's feasibility is developed. The efficiency of charcoal filtering and the atmospheric diffusion effect of an elevated air release are important for dose reduction. The performance of these functions was evaluated by confirmatory testing. The test results confirmed a 99 percent efficiency of charcoal filter and an atmospheric diffusion effect higher than that of a conventional plant. The Emergency Passive Air Filtration System (EPAFS) and the atmospheric diffusion effect of elevated air release contribute to making the calculated post-accident site boundary whole body dose of simplified PWR as low as that of the conventional Japanese PWR plant. (author)

  18. Industry-wide survey of organics in PWR's

    International Nuclear Information System (INIS)

    Byers, W.A.; Richards, J.E.; Hobart, S.A.

    1986-01-01

    Interest in organic impurities found in Pressurized Water Reactors (PWR's) has stemmed from several sources. The most serious concern is that organic acids will increase cation conductivity, a parameter that is used to control power plant chemistry. This effect can complicate secondary water monitoring and control. Organics may foul or exhaust makeup demineralizers and condensate polishers, and thus result in increased operating costs or the in leakage of potentially corrosive agents into the steam generators. Some organics, however, such as mopholine and cyclohexylamine may reduce corrosion through oxygen scavenging or surface filming reactions, and may have a positive influence on the pH in areas of local corrosion. At the time this survey began, little information was available on the types or levels of organic impurities that are typically found in PWR's. this survey is intended to provide baseline data for future corrosion testing and to provide fundamental information that will be helpful in refining PWR chemistry guidelines and operating practices

  19. The advanced main control console for next japanese PWR plants

    International Nuclear Information System (INIS)

    Tsuchiya, A.; Ito, K.; Yokoyama, M.

    2001-01-01

    The purpose of the improvement of main control room designing in a nuclear power plant is to reduce operators' workload and potential human errors by offering a better working environment where operators can maximize their abilities. In order to satisfy such requirements, the design of main control board applied to Japanese Pressurized Water Reactor (PWR) type nuclear power plant has been continuously modified and improved. the Japanese Pressurized Water Reactor (PWR) Utilities (Electric Power Companies) and Mitsubishi Group have developed an advanced main control board (console) reflecting on the study of human factors, as well as using a state of the art electronics technology. In this report, we would like to introduce the configuration and features of the Advanced Main Control Console for the practical application to the next generation PWR type nuclear power plants including TOMARI No.3 Unit of Hokkaido Electric Power Co., Inc. (author)

  20. Cylindrization of a PWR core for neutronic calculations

    International Nuclear Information System (INIS)

    Santos, Rubens Souza dos

    2005-01-01

    In this work we propose a core cylindrization, starting from a PWR core configuration, through the use of an algorithm that becomes the process automated in the program, independent of the discretization. This approach overcomes the problem stemmed from the use of the neutron transport theory on the core boundary, in addition with the singularities associated with the presence of corners on the outer fuel element core of, existents in the light water reactors (LWR). The algorithm was implemented in a computational program used to identification of the control rod drop accident in a typical PWR core. The results showed that the algorithm presented consistent results comparing with an production code, for a problem with uniform properties. In our conclusions, we suggest, for future works, for analyzing the effect on mesh sizes for the Cylindrical geometry, and to compare the transport theory calculations versus diffusion theory, for the boundary conditions with corners, for typical PWR cores. (author)

  1. Basic information about development and construction of a PWR

    International Nuclear Information System (INIS)

    Meyer, P.J.

    1977-01-01

    1.0) Plant layout of a PWR; 2.0) principle design of a PWR and the reactor coolant system; 3.0) reactor auxiliary and ancillary systems; 3.1) volume control system; 3.2) boric acid control and chemical feeding system; 3.3) coolant purification and degassing system; 3.4) coolant storage and treatment system; 3.5) nuclear component cooling system; 3.6) liquid waste processing system; 3.7) gaseous waste processing system; 4.0) residual heat removal system; 5.0) emergency feedwater system; 6.0) containment design; 7.0) fuel handling, storage and transport system in a PWR. (orig.) [de

  2. PWR fuel performance and future trend in Japan

    International Nuclear Information System (INIS)

    Kondo, Y.

    1987-01-01

    Since the first PWR power plant Mihama Unit 1 initiated its commercial operation in 1970, Japanese utilities and manufacturers have expended much of their resources and efforts to improve PWR technology. The results are already seen in significantly improved performance of 16 PWR plants now in operation. Mitsubishi Heavy Industries Ltd. (MHI) has been supplying them with nuclear fuel assemblies, which are over 5700. As the reliability of the current design fuel has been achieved, the direction of R and D on nuclear fuel has changed to make nuclear power more competitive to the other power generation methods. The most important R and D targets are the burnup extension, Gd contained fuel, Pu utilizatoin and the load follow capacility. (author)

  3. Swing-Down of 21-PWR Waste Package

    International Nuclear Information System (INIS)

    A.K. Scheider

    2001-01-01

    The objective of this calculation is to determine the structural response of the waste package (WP) swinging down from a horizontally suspended height. The WP used for that purpose is the 21-Pressurized Water Reactor (PWR) WP. The scope of this document is limited to reporting the calculation results in terms of stress intensities. This calculation is associated with the WP design and was performed by the Waste Package Design group in accordance with the ''Technical Work Plan for: Waste Package Design Description for LA'' (Ref. 13). AP-3.12Q, ''Calculations'' (Ref. 18) is used to perform the calculation and develop the document. The information provided by the sketches attached to this calculation is that of the potential design of the type of 21-PWR WP design considered in this calculation and provides the potential dimensions and materials for the 21-PWR WP design

  4. Load-following operation of PWR plants

    International Nuclear Information System (INIS)

    Jang, Jong Hwa; Oh, Soo Yul; Koo, Yang Hyun; Lee, Jae Han

    1993-12-01

    The load-following operation of nuclear power plants will become inevitable due to the increased nuclear share in the total electricity generation. As a groundwork for the load-following capability of the Korean next generation PWRs, the state-of-the-art has been reviewed. The core control principles and methods are the main subject in this review as well as the impact of load-following operations on the fuel performance and on the mechanical integrity of components. To begin with, it was described what the load-following operation is and in what view point the technology should be reviewed. Afterwards the load-following method, performance and problems in domestic 900 MWe class PWRs were discussed, and domestic R and D works were summarized. Foreign technologies were also reviewed. They include Mode G and Mode X of Foratom, D and L bank method of KWU, the method using PSCEA of ABB-CE, and MSHIM of Westinghouse. The load-following related special features of Foratom's N4 plant, KWU's plants, ABB-CE's Systems 80+, and Westinghouse's AP600 were described in each technology review. The review concluded that the capability of N4 plant with Mode X is the best and the methods in System, 80+ and AP600 would require verifications for the continued and usual load-following operation. It was recommended that the load-following operation experiences in domestic PWRs under operation be required to settle down the capability for the future. In addition, a more enhanced technology is required for the Korean next generation PWR regardless what the reference plant concept is. 30 figs., 19 tabs., 75 refs. (Author)

  5. Burnable Absorber-Filled Annular UO{sub 2} Fuels for PWR

    Energy Technology Data Exchange (ETDEWEB)

    Yahya, Mohd-Syukri; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of); Chung, ChangKyu [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    Its central annulus hole also provides an additional plenum for the fission gas release. In fact, annular UO{sub 2} fuels have successfully been used in commercial Russian's nuclear reactors for decades. It was upon this notion that a study was recently performed to re-investigate neutronic characteristics of the annular fuel in a rod-cell lattice. The said study also proposed an innovative integral burnable absorber (BA) concept by loading of a porous BA rod inside central hole of the annular fuel. This current work aims to extend the said investigation by characterizing neutronic performances of the BA-filled annular fuels in standard PWR 17x17 and 16x16 fuel assembly lattices. Preliminary results suggested promising potentials of the novel BA concept in managing the assembly lattice reactivity and power peaking. All calculations were performed using the Monte Carlo Serpent code with ENDF/B7.0 library. This paper demonstrates neutronic feasibilities of the BA-filled annular fuels in standard PWR 17x17 and 16x16 fuel assembly lattices. One notes that the BA-filled annular fuel-loaded lattice display comparable neutronic characteristics to the benchmarked commercial BA designs, especially in terms of reactivity and peaking factor management.

  6. The latest full-scale PWR simulator in Japan

    International Nuclear Information System (INIS)

    Nishimuru, Y.; Tagi, H.; Nakabayashi, T.

    2004-01-01

    The latest MHI Full-scale Simulator has an excellent system configuration, in both flexibility and extendability, and has highly sophisticated performance in PWR simulation by the adoption of CANAC-II and PRETTY codes. It also has an instructive character to display the plant's internal status, such as RCS condition, through animation. Further, the simulation has been verified to meet a functional examination at model plant, and with a scale model test result in a two-phase flow event, after evaluation for its accuracy. Thus, the Simulator can be devoted to a sophisticated and broad training course on PWR operation. (author)

  7. The traveller: a new look for PWR fresh fuel packages

    International Nuclear Information System (INIS)

    Bayley, B.; Stilwell, W.E.; Kent, N.A.

    2004-01-01

    The Traveller PWR fresh fuel shipping package represents a radical departure from conventional PWR fuel package designs. This paper follows the development effort from the establishment of goals and objectives, to intermediate testing and analysis, to final testing and licensing. The discussion starts with concept origination and covers the myriad iterations that followed until arriving at a design that would meet the demanding licensing requirements, last for 30 years, and would be easy to load and unload fuel, easy to handle, inexpensive to manufacture and transport, and simple and inexpensive to maintain

  8. Sensitivity of risk parameters to human errors for a PWR

    International Nuclear Information System (INIS)

    Samanta, P.; Hall, R.E.; Kerr, W.

    1980-01-01

    Sensitivities of the risk parameters, emergency safety system unavailabilities, accident sequence probabilities, release category probabilities and core melt probability were investigated for changes in the human error rates within the general methodological framework of the Reactor Safety Study for a Pressurized Water Reactor (PWR). Impact of individual human errors were assessed both in terms of their structural importance to core melt and reliability importance on core melt probability. The Human Error Sensitivity Assessment of a PWR (HESAP) computer code was written for the purpose of this study

  9. Structures and Materials of Reactor Internals for PWR in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. W.; Kim, W. S.; Kwon, S. C.; Kwon, J. H.; Kim, Y. S.; Kim, H. P.; Yoo, C. S.; Lee, S. R.; Jung, M. K.; Hwang, S. S

    2007-10-15

    Nuclear reactor types in Korea are PWR type reactor (Westinghouse, Combustion Engineering, Farmatome type) and CANDU type reactor. Structures and Materials for reactor internal of PWR type were investigated. Reactor internal was composed of lower core support structure, upper core support assembly, incore instrumentation support structure. Lower core support structure of these structures is the most important. The major material for the reactor internal is type 304 and 316 stainless steel and radial support clevis bolts are made of Inconel. The main damage mechanism for reactor internal was IASCC and the effect of IASCC on reactor internal was investigated. The accident for reactor internal was also investigate.

  10. PHEDRE model for the simulation of PWR reactors

    International Nuclear Information System (INIS)

    Bernard, Patrice; Dupraz, Remy; Vasile, Alfredo.

    1979-11-01

    This note presents the model of PHEDRE, simulator of a PWR, set on the hybrid computers of CISI, at the Nuclear Research Center of Cadarache. The model mainly concerns the primary part and the steam production of the PWR constructed in France. It includes an axial modelization of the core, the pressurizer, two loops of steam production and the inlet of the turbine, and the regulations concerning these components. The note presents the equations of the model, the structures of the codes concerning the initialization and the dynamic resolution, and describes the control panel of PHEDRE [fr

  11. Leak before break application in French PWR plants under operation

    Energy Technology Data Exchange (ETDEWEB)

    Faidy, C. [EDF SEPTEN, Villeurbanne (France)

    1997-04-01

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  12. Transient performance of flow in PWR reactor circuits

    International Nuclear Information System (INIS)

    Hirdes, V.R.T.R.; Carajilescov, P.

    1988-12-01

    Generally, PWR's are designed with several primary loops, each one provided with a pump to circulate the coolant through the core. If one or more of these pumps fail, there would be a decrease in reactor flow rate which cause coolant phase change in the core and components overheating. The present work establishes a simulation model for pump failure in PWR's and the SARDAN-FLOW computes code was developed, considering any combination of such failures. Based on the data of Angra I, several accident and operational transient conditions were simulated. (author) [pt

  13. Transient performance of flow in circuits of PWR type reactors

    International Nuclear Information System (INIS)

    Hirdes, V.R.; Carajilescov, P.

    1988-09-01

    Generally, PWR's are designed with several primary loops, each one provided with a pump to circulate the coolant through the core. If one or more of these pumps fail, there would be a decrease in reactor flow rate which could cause coolant phase change in the core and components overheating. The present work establishes a simulation model for pump failure in PWR's and the SARDAN-FLOW computes code was developed, considering any combination of such failures. Based on the data of Angra I, several accident and operational transient conditions were simulated. (author) [pt

  14. Physics of plutonium and americium recycling in PWR using advanced fuel concepts

    International Nuclear Information System (INIS)

    Hourcade, E.

    2004-01-01

    PWR waste inventory management is considered in many countries including Frances as one of the main current issues. Pu and Am are the 2 main contents both in term of volume and long term radio-toxicity. Waiting for the Generation IV systems implementation (2035-2050), one of the mid-term solutions for their transmutation involves the use of advanced fuels in Pressurized Water Reactors (PWR). These have to require as little modification as possible of the core internals, the cooling system and fuel cycle facilities (fabrication and reprocessing). The first part of this paper deals with some neutronic characteristics of Pu and/or Am recycling. In a second part, 2 technical solutions MOX-HMR and APA-DUPLEX-84 are presented and the third part is devoted to the study of a few global strategies. The main neutronic parameters to be considered for Pu and Am recycling in PWR are void coefficient, Doppler coefficient, fraction of delayed neutrons and power distribution (especially for heterogeneous configurations). The modification of the moderation ratio, the opportunity to use inert matrices (targets), the optimisation of Uranium, Plutonium and Americium contents are the key parameters to play with. One of the solutions (APA-DUPLEX-84) presented here is a heterogeneous assembly with regular moderation ratio composed with both target fuel rods (Pu and Am embedded in an inert matrix) and standard UO 2 fuel rods. An EPR (European Pressurised Reactor) type reactor, loaded only with assemblies containing 84 peripheral targets, can reach an Americium consumption rate of (4.4; 23 kg/TWh) depending on the assembly concept. For Pu and Am inventories stabilisation, the theoretical fraction of reactors loaded with Pu + Am or Pu assemblies is about 60%. For Americium inventory stabilisation, the fraction decreases down to 16%, but Pu is produced at a rate of 18.5 Kg/TWh (-25% compared to one through UOX cycle)

  15. Criticality analysis of PWR spent fuel storage facilities inside nuclear power plants

    International Nuclear Information System (INIS)

    Neuber, J.C.

    1999-01-01

    This paper describes some of the main features of the actinide plus fission product burnup credit methodology used by Siemens for criticality safety design analysis of wet PWR storage pools with soluble boron in the pool water. Application of burnup credit requires knowledge of the isotopic inventory of the irradiated fuel for which burnup credit is taken. This knowledge is gained by using depletion codes. The results of the depletion analysis are a necessary input to the criticality analysis. Siemens performs depletion calculations for PWR fuel burnup credit applications with the aid of the Siemens standard design procedure SAV90. The quality of this procedure relies on statistics on the differences between calculation and measurement extracted from in-core measurement data and chemical assay data. Siemens performs criticality safety calculations with the aid of the criticality calculation modules of the SCALE code package. These modules are verified many times with the aid of various kinds of critical experiments and configurations: Application of these modules to spent LWR fuel assembly storage pools was verified by analyzing critical experiments simulating such storage pools. Actinide plus fission product burnup credit applications of these modules were verified by analyzing PWR reactor critical configurations. The result of performing a burnup credit analysis is the determination of a burnup, credit loading curve for the spent fuel storage racks designed for burnup credit. This curve specifies the loading criterion by indicating the minimum burnup necessary for the fuel assembly with a specific initial enrichment to be placed in the storage racks designed for burnup credit. The loading of the spent fuel storage racks designed for burnup credit requires the implementation of controls to ensure that the loading curve is met. The controls include the determination of fuel assembly burnup based on reactor records. (author)

  16. Comparison between HELIOS calculations and a PWR cell benchmark for actinides transmutation

    Energy Technology Data Exchange (ETDEWEB)

    Guzman, Rafael [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Mor. (Mexico); Francois, Juan-Luis [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Mor. (Mexico)]. E-mail: jlfl@fi-b.unam.mx

    2007-01-15

    This paper shows a comparison between the results obtained with the HELIOS code and other similar codes used in the international community, with respect to the transmutation of actinides. To do this, the international benchmark: 'Calculations of Different Transmutation Concepts' of the Nuclear Energy Agency is analyzed. In this benchmark, two types of cells are analyzed: a small cell corresponding to a standard pressurized water reactor (PWR), and a wide cell corresponding to a highly moderated PWR. Two types of discharge burnup are considered: 33 GWd/tHM and 50 GWd/tHM. The following results are analyzed: the neutron multiplication factor as a function of burnup, the atomic density of the principal actinide isotopes, the radioactivity of selected actinides at reactor shutdown and cooling times from 7 until 50,000 years, the void reactivity and the Doppler reactivity. The results are compared with the following codes: KAPROS/KARBUS (FZK, Germany), SRAC95 (JAERI, Japan), TRIFON (ITTEP, Russian Federation) and WIMS (IPPE, Russian Federation). For the neutron multiplication factor, the results obtained with HELIOS show a difference of around 1% {delta}k/k. For the isotopic concentrations: {sup 241}Pu, {sup 242}Pu, and {sup 242m}Am, the results of all the institutions present a difference that increases at higher burnup; for the case of {sup 237}Np, the results of FZK diverges from the other results as the burnup increases. Regarding the activity, the difference of the results is acceptable, except for the case of {sup 241}Pu. For the Doppler coefficient, the results are acceptable, except for the cells with high moderation. In the case of the void coefficient, the difference of the results increases at higher void fractions, being the highest at 95%. In summary, for the PWR benchmark, the results obtained with HELIOS agree reasonably well within the limits of the multiple plutonium recycling established by the NEA working party on plutonium fuels and

  17. Methodology for the LABIHS PWR simulator modernization

    Energy Technology Data Exchange (ETDEWEB)

    Jaime, Guilherme D.G.; Oliveira, Mauro V., E-mail: gdjaime@ien.gov.b, E-mail: mvitor@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The Human-System Interface Laboratory (LABIHS) simulator is composed by a set of advanced hardware and software components whose goal is to simulate the main characteristics of a Pressured Water Reactor (PWR). This simulator serves for a set of purposes, such as: control room modernization projects; designing of operator aiding systems; providing technological expertise for graphical user interfaces (GUIs) designing; control rooms and interfaces evaluations considering both ergonomics and human factors aspects; interaction analysis between operators and the various systems operated by them; and human reliability analysis in scenarios considering simulated accidents and normal operation. The simulator runs in a PA-RISC architecture server (HPC3700), developed nearby 2000's, using the HP-UX operating system. All mathematical modeling components were written using the HP Fortran-77 programming language with a shared memory to exchange data from/to all simulator modules. Although this hardware/software framework has been discontinued in 2008, with costumer support ceasing in 2013, it is still used to run and operate the simulator. Due to the fact that the simulator is based on an obsolete and proprietary appliance, the laboratory is subject to efficiency and availability issues, such as: downtime caused by hardware failures; inability to run experiments on modern and well known architectures; and lack of choice of running multiple simulation instances simultaneously. This way, there is a need for a proposal and implementation of solutions so that: the simulator can be ported to the Linux operating system, running on the x86 instruction set architecture (i.e. personal computers); we can simultaneously run multiple instances of the simulator; and the operator terminals run remotely. This paper deals with the design stage of the simulator modernization, in which it is performed a thorough inspection of the hardware and software currently in operation. Our goal is to

  18. Methodology for the LABIHS PWR simulator modernization

    International Nuclear Information System (INIS)

    Jaime, Guilherme D.G.; Oliveira, Mauro V.

    2011-01-01

    The Human-System Interface Laboratory (LABIHS) simulator is composed by a set of advanced hardware and software components whose goal is to simulate the main characteristics of a Pressured Water Reactor (PWR). This simulator serves for a set of purposes, such as: control room modernization projects; designing of operator aiding systems; providing technological expertise for graphical user interfaces (GUIs) designing; control rooms and interfaces evaluations considering both ergonomics and human factors aspects; interaction analysis between operators and the various systems operated by them; and human reliability analysis in scenarios considering simulated accidents and normal operation. The simulator runs in a PA-RISC architecture server (HPC3700), developed nearby 2000's, using the HP-UX operating system. All mathematical modeling components were written using the HP Fortran-77 programming language with a shared memory to exchange data from/to all simulator modules. Although this hardware/software framework has been discontinued in 2008, with costumer support ceasing in 2013, it is still used to run and operate the simulator. Due to the fact that the simulator is based on an obsolete and proprietary appliance, the laboratory is subject to efficiency and availability issues, such as: downtime caused by hardware failures; inability to run experiments on modern and well known architectures; and lack of choice of running multiple simulation instances simultaneously. This way, there is a need for a proposal and implementation of solutions so that: the simulator can be ported to the Linux operating system, running on the x86 instruction set architecture (i.e. personal computers); we can simultaneously run multiple instances of the simulator; and the operator terminals run remotely. This paper deals with the design stage of the simulator modernization, in which it is performed a thorough inspection of the hardware and software currently in operation. Our goal is to

  19. Qualitative analysis of the maintenance politics of the systems of a typical PWR by artificial neural networks; Analise qualitativa da politica de manutencoes dos sistemas de um PWR tipico por redes neurais artificiais

    Energy Technology Data Exchange (ETDEWEB)

    Lourenco, Victor Hugo Moreno

    2010-02-15

    Proceedings and techniques in order to maximize the reliability and the availability of industrial plants have been used along the last decades by specialists and professionals of maintenance. However, the modem industrial systems' sizing, and the increasing complexity and interdependence among its components have become this activity's planning a more and more difficult task. Considering this scenario, the objective of the present work is to provide a computational tool which is able to help about the taking decision's task, and about planning policies of maintenance practiced in thermonuclear plants. The tool developed is based on the artificial neural networks (ANN) for the recognition of standards and establishment of correlations among events occurred in the components of pressurized water reactor (PWR) typical systems. The ANN work as miners of database of failure events, and are able to identify connections and to establish imperceptible inferences even for the most experienced specialists in maintenance of nuclear systems. The results were attained from realistic data and are confronted against the maintenance's classic policies which are practiced nowadays on PWR thermonuclear plants. These results show the solidity of the technique in valuing and predicting failures in a real power plant, and is able to be used as a tool for supporting decisions about planning maintenance policies on a typical PWR. (author)

  20. Directives and general design requirements for a small PWR

    International Nuclear Information System (INIS)

    Arrieta, L.A.

    1992-08-01

    A proposal of directives and general requirements for the development of a small PWR conceptual design is presented. These directives address the main safety, performance and economic design aspects. The purpose is to use this work as a base for a wide discussion, involving all project participants, culminating with the definition of the final directives and general requirements. (author)

  1. Seismic analysis of the core of a PWR reactor

    International Nuclear Information System (INIS)

    Preumont, A.

    1981-01-01

    The author develops successively: - a method for the generation of accelerograms compatible with the response spectrum; a model for the analysis of lateral deformations of the core of a PWR reactor under seismic excitation; a simple dynamic model of the fuel assembly including a vibration model. (MD)

  2. Post irradiation examination on test fuel pins for PWR

    International Nuclear Information System (INIS)

    Fogaca Filho, N.; Ambrozio Filho, F.

    1981-01-01

    Certain aspects of irradiation technology on test fuel pins for PWR, are studied. The results of post irradiation tests, performed on test fuel pins in hot cells, are presented. The results of the tests permit an evaluation of the effects of irradiation on the fuel and cladding of the pin. (Author) [pt

  3. Reactor core design calculations and fuel management in PWR

    International Nuclear Information System (INIS)

    Ravnik, M.

    1987-01-01

    Computer programs and methods developed at J. Stefan Institute for nuclear core design of Krsko NPP are treated. development, scope, verification and organisation of core design procedure are presented. The core design procedure is applicable to any NPP of PWR type. (author)

  4. Make use of EDF orientations in PWR fuel management

    International Nuclear Information System (INIS)

    Gloaguen, A.

    1989-01-01

    The EDF experience acquired permits to allow the PWR fuel performances and to make use of better management. In this domain low progress can be given considerable financial profits. The industrial and commercial structures, the time constant of the fuel cycle, has for consequence that the electric utilities can take advantage only progressively of the expected profits [fr

  5. Design of a PWR emergency core cooling simulator loop

    International Nuclear Information System (INIS)

    Melo, C.A. de.

    1982-12-01

    The preliminary design of a PWR Emergency Core Cooling Simulator Loop for investigations of the phenomena involved in a postulated Loss-of-Coolant Accident, during the Reflooding Phase, is presented. The functions of each component of the loop, the design methods and calculations, the specification of the instrumentation, the system operation sequence, the materials list and a cost assessment are included. (Author) [pt

  6. Exhaust air cleaning of PWR nuclear power plants

    International Nuclear Information System (INIS)

    Wang Rufan.

    1987-01-01

    This paper describes requirements, design criteria and major equipments of exhaust air cleaning for PWR nuclear power plants. The particularity of exhaust air cleaning for NPP is stressed in this paper. Finally, the exhaust air cleaning systems of Qinshan NPP are briefly introduced

  7. Contribution to study and design of PWR plant simulation code

    International Nuclear Information System (INIS)

    Delourme, Didier.

    1980-11-01

    This paper presents an improvement of PICOLO, a package for PWR plants simulation. Its describes principally the integration to the code of a primary loop and pressurizer model and the corresponding control loops. Fast transients are tested on the packages and results are compared with real transients obtained on plants [fr

  8. Fabrication of DUPIC fuel pellets using high burn-up spent PWR fuel

    International Nuclear Information System (INIS)

    Lee, Jung-Won; Park, Geun-Il; Choi, Yong

    2012-01-01

    Technology for the direct usage of a spent PWR fuel in CANDU reactors (DUPIC) was developed in KAERI to reduce the amount of spent fuel. DUPIC fuel pellets were fabricated using a dry processing method to re-fabricate CANDU fuel from spent PWR fuel without any intentional separation of fissile materials or fission products. The DUPIC fuel element fabrication process satisfied a quality assurance program in accordance with the Canadian standard. For the DUPIC fuels with various fuel burn-ups between 27,300 and 65,000 MWd/tU, the sintered pellet density decreased with increasing fuel burn-ups. Fission gas releases and powder properties of the spent fuel also influenced the DUPIC fuel characteristics. Measurement of cesium content released from green pellets revealed that their sintered density significantly depended on sintering temperature history. It was useful to establish a DUPIC fuel fabrication technology in which a high-burn-up fuel with 65,000 MWd/tU was treated. (author)

  9. Analysis of the return to power scenario following a LBLOCA in a PWR

    Energy Technology Data Exchange (ETDEWEB)

    Macian, R.; Tyler, T.N.; Mahaffy, J.H. [Pennsylvania State Univ., University Park, PA (United States)

    1995-09-01

    The risk of reactivity accidents has been considered an important safety issue since the beginning of the nuclear power industry. In particular, several events leading to such scenarios for PWR`s have been recognized and studied to assess the potential risk of fuel damage. The present paper analyzes one such event: the possible return to power during the reflooding phase following a LBLOCA. TRAC-PF1/MOD2 coupled with a three-dimensional neutronic model of the core based on the Nodal Expansion Method (NEM) was used to perform the analysis. The system computer model contains a detailed representation of a complete typical 4-loop PWR. Thus, the simulation can follow complex system interactions during reflooding, which may influence the neutronics feedback in the core. Analyses were made with core models bases on cross sections generated by LEOPARD. A standard and a potentially more limiting case, with increased pressurizer and accumulator inventories, were run. In both simulations, the reactor reaches a stable state after the reflooding is completed. The lower core region, filled with cold water, generates enough power to boil part of the incoming liquid, thus preventing the core average liquid fraction from reaching a value high enough to cause a return to power. At the same time, the mass flow rate through the core is adequate to maintain the rod temperature well below the fuel damage limit.

  10. Qualitative analysis of the maintenance politics of the systems of a typical PWR by artificial neural networks

    International Nuclear Information System (INIS)

    Lourenco, Victor Hugo Moreno

    2010-02-01

    Proceedings and techniques in order to maximize the reliability and the availability of industrial plants have been used along the last decades by specialists and professionals of maintenance. However, the modem industrial systems' sizing, and the increasing complexity and interdependence among its components have become this activity's planning a more and more difficult task. Considering this scenario, the objective of the present work is to provide a computational tool which is able to help about the taking decision's task, and about planning policies of maintenance practiced in thermonuclear plants. The tool developed is based on the artificial neural networks (ANN) for the recognition of standards and establishment of correlations among events occurred in the components of pressurized water reactor (PWR) typical systems. The ANN work as miners of database of failure events, and are able to identify connections and to establish imperceptible inferences even for the most experienced specialists in maintenance of nuclear systems. The results were attained from realistic data and are confronted against the maintenance's classic policies which are practiced nowadays on PWR thermonuclear plants. These results show the solidity of the technique in valuing and predicting failures in a real power plant, and is able to be used as a tool for supporting decisions about planning maintenance policies on a typical PWR. (author)

  11. Zinc injection in German PWR plants

    International Nuclear Information System (INIS)

    Streit, K.

    2004-01-01

    Operating experience acquired at PWR NNPs shows that zinc injection at low concentrations of 5 ppb is a very effective source term reduction measure. This method does not lead to any operating restrictions or other negative effects on plant systems and components. The nuclear industry has been very successful in reducing radiation exposures within the past two decades. Annual exposures could be significantly decreased and are now at a level of around 1 man-Sv per plant and year. This great success can mainly be attributed to the general commitment of plant operators to maintaining radiation exposures of workers in the controlled access area as low as reasonably achievable (ALARA principle). The ALARA principle, of course, also implies evaluation of the economic benefit of radiation protection measures. Radiation source term reduction has drawn increasing attention of plant operators in recent years. For the new PWRs cobalt-based alloys in the primary system have successively been eliminated already at the design and construction phase within the last decade. Use of wear-resistant cobalt-free substitute materials in combination with the general use of advanced alloys for the steam generator tubing of PWRs resulted in low values for the two most common sources of plant radiation fields, namely 58 Co and 60 Co. Investigations showed that the beneficial effect of zinc can be related to its high affinity for mixed spinel oxide phases, resulting in the following two basic effects: -Zinc is incorporated preferentially into the oxide layer on primary system surfaces and thus reduces pickup of 58 Co and 60 Co and - Zinc can displace cobalt isotopes from existing oxide layers. In German PWRs with Incoloy 800 steam generator tubing material (Ni-content -32%), the observed reductions correspond to a decrease in dose rates of around 10 to 15% per year and thus follow, as predicted, the half-life time of 60 Co. Overall reductions in high radiation areas are now in the range of

  12. Gadolinia experience and design for PWR fuel cycles

    International Nuclear Information System (INIS)

    Stephenson, L. C.

    2000-01-01

    The purpose of this paper is to describe Siemens Power Corporation's (SPC) current experience with the burnable absorber gadolinia in PWR fuel assemblies, including optimized features of SPC's PWR gadolinia designs, and comparisons with other burnable absorbers. Siemens is the world leader in PWR gadolinia experience. More than 5,900 Siemens PWR gadolinia-bearing fuel assemblies have been irradiated. The use of gadolinia-bearing fuel provides significant flexibility in fuel cycle designs, allows for low radial leakage fuel management and extended operating cycles, and reduces BOC (beginning-of-cycle) soluble boron concentrations. The optimized use of an integral burnable neutron absorber is a design feature which provides improved economic performance for PWR fuel assemblies. This paper includes a comparison between three different types of integral burnable absorbers: gadolinia, Zirconium diboride and erbia. Fuel cycle design studies performed by Siemens have shown that the enrichment requirements for 18-24 month fuel cycles utilizing gadolinia or zirconium diboride integral fuel burnable absorbers can be approximately the same. Although a typical gadolinia residual penalty for a cycle design of this length is as low as 0.02-0.03 wt% U-235, the design flexibility of gadolinia allows for very aggressive low-leakage core loading plans which reduces the enrichment requirements for gadolinia-bearing fuel. SPC has optimized its use of gadolinia in PWR fuel cycles. Typically, low (2-4) weight percent Gd 2 O 3 is used for beginning to middle of cycle reactivity hold down as well as soluble boron concentration holddown at BOC. Higher concentrations of Gd 2 O 3 , such as 6 and 8 wt%, are used to control power peaking in assemblies later in the cycle. SPC has developed core strategies that maximize the use of lower gadolinia concentrations which significantly reduces the gadolinia residual reactivity penalty. This optimization includes minimizing the number of rods with

  13. On the impact analysis of a PWR spacer grid

    International Nuclear Information System (INIS)

    Song, Kee Nam; Lee, S. H.

    2012-01-01

    A spacer grid, which is an interconnected array of slotted grid straps and is welded at the intersections to form an egg crate structure, is one of the most important structural components in a PWR fuel assembly. From a structural point of view, the spacer grid is required to have sufficient crush strength under lateral loads so that nuclear fuel rods are maintained in a cool able geometry, and that control rods can be inserted. The capacity of a spacer grid to resist lateral loads is usually characterized in terms of its crush strength, and it was reported that the lateral crush strength of the spacer grid is closely related with welding quality of the spacer grid. Microstructures in the weld zone, including a heat affected zone (HAZ), are different from that in a parent material. Consequently, the mechanical properties in the weld zone are different from those in the parent material to some extent. When a welded structure is loaded, the mechanical behavior of the welded structure might be different from the case of a structure with homogeneous mechanical properties. Nonetheless, mechanical properties in the welded structure have been neglected in many structural analyses of the spacer grid due to a lack of mechanical properties in the weld zone. When the weld zone is very narrow and the interfaces are not clear, it is difficult to take tensile test specimens in the weld zone. The reason for this is that the mechanical properties in the parent material are usually used in the structural analyses in the welded structure. As an aside, it has been recently determined that the ball indentation technique has the potential to be an excellent substitute for a standard tensile test, particularly in the case of small specimens or property gradient materials such as welds. In this study, to investigate the effect on the mechanical behavior of the spacer grid when using weld mechanical properties, strength analyses considering the weld mechanical properties recently obtained

  14. A concept of PWR using plate and shell heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Luciano Ondir; Andrade, Delvonei Alves de, E-mail: luciano.ondir@gmail.com, E-mail: delvonei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    In previous work it was verified the physical possibility of using plate and shell heat exchangers for steam generation in a PWR for merchant ships. This work studies the possibility of using GESMEX commercial of the shelf plate and shell heat exchanger of series XPS. It was found it is feasible for this type of heat exchanger to meet operational and accidental requirements for steam generation in PWR. Additionally, it is proposed an arrangement of such heat exchangers inside the reactor pressure vessel. Such arrangement may avoid ANSI/ANS51.1 nuclear class I requirements on those heat exchangers because they are contained in the reactor coolant pressure barrier and play no role in accidental scenarios. Additionally, those plates work under compression, preventing the risk of rupture. Being considered non-nuclear safety, having a modular architecture and working under compression may turn such architectural choice a must to meet safety objectives with improved economics. (author)

  15. The plutonium recycle for PWR reactors from brazilian nuclear program

    International Nuclear Information System (INIS)

    Rubini, L.A.

    1978-01-01

    The purpose of this thesis is to evaluate the material requirements of the nuclear fuel cycle with plutonium recycle. The study starts with the calculation of a reference reactor and has flexibility to evaluate the demand under two alternatives of nuclear fuel cycle for Pressurized Water Reactors (PWR): Without plutonium recycle; and with plutonium recycle. Calculations of the reference reactor have been carried out with the CELL-CORE codes. Variations in the material requirements were studied considering changes in the installed nuclear capacity of PWR reactors, the capacity factor of these reactors, and the introduction of fast breeders. Recycling plutonium produced inside the system can reach economies of about 5% U 3 O 8 and 6% separative work units if recycle is assumed only after the fifth operation cycle of the thermal reactors. (author)

  16. Report on the PWR-radiation protection/ALARA Committee

    Energy Technology Data Exchange (ETDEWEB)

    Malone, D.J. [Consumers Power Co., Covert, MI (United States)

    1995-03-01

    In 1992, representatives from several utilities with operational Pressurized Water Reactors (PWR) formed the PWR-Radiation Protection/ALARA Committee. The mission of the Committee is to facilitate open communications between member utilities relative to radiation protection and ALARA issues such that cost effective dose reduction and radiation protection measures may be instituted. While industry deregulation appears inevitable and inter-utility competition is on the rise, Committee members are fully committed to sharing both positive and negative experiences for the benefit of the health and safety of the radiation worker. Committee meetings provide current operational experiences through members providing Plant status reports, and information relative to programmatic improvements through member presentations and topic specific workshops. The most recent Committee workshop was facilitated to provide members with defined experiences that provide cost effective ALARA performance.

  17. Three basic options for the management of PWR waste

    International Nuclear Information System (INIS)

    Malherbe, J.; Saulieu, E. de; Glibert, R.; Alamo Berna, S.; Cecille, L.; Geiser, H.; Kowa, S.; Thiels, G.

    1990-01-01

    Relying on the national practices of France, Germany and Belgium, three reference management routes for PWR wastes were drawn up and subsequently evaluated in terms of costs and radiological impact. It was thus demonstrated that safety regulations and technical redundancies, especially for off-gas treatment, liquid waste processing and dry solid waste treatment, play an important part in the cost associated with each route. The analysis of the different treatment options for mixed solid low level waste highlighted the low cost effectiveness of incineration as compared to compaction. Whatever the scenario investigated, the disposal costs of PWR wastes proved to be quite marginal in the overall cost. The radiological impact associated with each route was assessed through individual doses resulting from liquid and gaseous effluents. This theoretical exercise included some sensitivity studies performed on a selection of important parameters

  18. Thermal hydraulic simulations of the Angra 2 PWR

    Directory of Open Access Journals (Sweden)

    González-Mantecón Javier

    2015-01-01

    Full Text Available Angra 2, the second Brazilian nuclear power plant, began the commercial operation in 2001. The plant is a pressurized water reactor (PWR type with electrical output of about 1350 MW. In the present work, the thermal hydraulic RELAP5-3D code was used to develop a model of this reactor. The model was performed using geometrical and material data from the Angra 2 final safety analysis report (FSAR. Simulations of the reactor behavior during steady state and loss of coolant accident were performed. Results of temperature distribution within the core, inlet and outlet coolant temperatures, coolant mass flow, and other parameters have been compared with the reference data and demonstrated to be in good agreement with each other. This study demonstrates that the developed RELAP5-3D model is capable of reproducing the thermal hydraulic behavior of the Angra 2 PWR and it can contribute to the process of the plant safety analysis.

  19. A concept of PWR using plate and shell heat exchangers

    International Nuclear Information System (INIS)

    Freire, Luciano Ondir; Andrade, Delvonei Alves de

    2015-01-01

    In previous work it was verified the physical possibility of using plate and shell heat exchangers for steam generation in a PWR for merchant ships. This work studies the possibility of using GESMEX commercial of the shelf plate and shell heat exchanger of series XPS. It was found it is feasible for this type of heat exchanger to meet operational and accidental requirements for steam generation in PWR. Additionally, it is proposed an arrangement of such heat exchangers inside the reactor pressure vessel. Such arrangement may avoid ANSI/ANS51.1 nuclear class I requirements on those heat exchangers because they are contained in the reactor coolant pressure barrier and play no role in accidental scenarios. Additionally, those plates work under compression, preventing the risk of rupture. Being considered non-nuclear safety, having a modular architecture and working under compression may turn such architectural choice a must to meet safety objectives with improved economics. (author)

  20. Studi Operasi Resin Penukar Ion Dalam Sistem Purifikasi Air Primer Pwr

    OpenAIRE

    Biyantoro, Dwi; Basuki, Kris Tri; Subagiono, Subagiono

    2006-01-01

    STUDI OPERASI RESIN PENUKAR ION DALAM SISTEM PURIFIKASI AIR PRIMER PWR. Telah dilakukan studioperasi resin penukar ion dalam sistem purifikasi air primer PWR. Air pendingin reaktor yang pada awalnya sesuaidengan persyaratan setelah pengoperasian reaktor sering kualitasnya berubah, sehingga harus dimurnikan. Unsurunsurpengotor dalam air primer PWR diidentifikasi sebagai penyebab pengotor seperti korosi, pelepasan produk fisi(Cs137, Sr90, Co60,C14, Tc99), dan pelepasan kembali unsur oleh resin ...

  1. Uranium savings on a once through PWR fuel cycle

    International Nuclear Information System (INIS)

    Cupo, J.V.

    1980-01-01

    A number of alternatives which have the greatest potential for near term savings with minimum plant and fuel modifications have been examined at Westinghouse as part of continued internal assessment and part of NASAP study conducted for DOE pertaining to uranium utilization in a once through PWR fuel cycle. The alternatives which could be retrofitted to existing reactors were examined in more detail in the evaluation since they would have the greater near term impact on U savings

  2. Study on thermal-hydraulics during a PWR reflood phase

    International Nuclear Information System (INIS)

    Iguchi, Tadashi

    1998-10-01

    In-core thermal-hydraulics during a PWR reflood phase following a large-break LOCA are quite unique in comparison with two-phase flow which has been studied widely in previous researches, because the geometry of the flow path is complicated (bundle geometry) and water is at extremely low superficial velocity and almost under stagnant condition. Hence, some phenomena realized during a PWR reflood phase are not understood enough and appropriate analytical models have not been developed, although they are important in a viewpoint of reactor safety evaluation. Therefore, author investigated some phenomena specified as important issues for quantitative prediction, i.e. (1) void fraction in a bundle during a PWR reflood phase, (2) effect of radial core power profile on reflood behavior, (3) effect of combined emergency core coolant injection on reflood behavior, and (4) the core separation into two thermal-hydraulically different regions and the in-core flow circulation behavior observed during a combined injection PWR reflood phase. Further, author made analytical models for these specified issues, and succeeded to predict reflood behaviors at representative types of PWRs, i.e.cold leg injection PWRs and Combined injection PWRs, in good accuracy. Above results were incorporated into REFLA code which is developed at JAERI, and they improved accuracy in prediction and enlarged applicability of the code. In the present study, models were intended to be utilized in a practical use, and hence these models are simplified ones. However, physical understanding on the specified issues in the present study is basic and principal for reflood behavior, and then it is considered to be used in a future advanced code development and improvement. (author). 110 refs

  3. Improvement on main control room for Japanese PWR plants

    International Nuclear Information System (INIS)

    Matsumiya, Masayuki

    1996-01-01

    The main control room which is the information center of nuclear power plant has been continuously improved utilizing the state of the art ergonomics, a high performance computer, computer graphic technologies, etc. For the latest Japanese Pressurized Water Reactor (PWR) plant, the CRT monitoring system is applied as the major information source for facilitating operators' plant monitoring tasks. For an operating plant, enhancement of monitoring and logging functions has been made adopting a high performance computer

  4. ORNL-PWR BDHT analysis procedure: an overview

    International Nuclear Information System (INIS)

    Cliff, S.B.

    1978-01-01

    The key computer programs currently used by the analysis procedure of the ORNL-PWR Blowdown Heat Transfer Separate Effects Program are overviewed with particular emphasis placed on their interrelationships. The major modeling and calculational programs, COBRA, ORINC, ORTCAL, PINSIM, and various versions of RELAP4, are summarized and placed into the perspective of the procedure. The supportive programs, REDPLT, ORCPLT, BDHTPLOT, OXREPT, and OTOCI, and their uses are described

  5. Optimal design of passive containment cooling system for innovative PWR

    OpenAIRE

    Huiun Ha; Sangwon Lee; Hangon Kim

    2017-01-01

    Using the Generation of Thermal-Hydraulic Information for Containments (GOTHIC) code, thermal-hydraulic phenomena that occur inside the containment have been investigated, along with the preliminary design of the passive containment cooling system (PCCS) of an innovative pressurized water reactor (PWR). A GOTHIC containment model was constructed with reference to the design data of the Advanced Power Reactor 1400, and report related PCCS. The effects of the design parameters were evaluated fo...

  6. Methodology of safety operating range determination for the PWR plant

    International Nuclear Information System (INIS)

    Kostadinov, V.; Mavko, B.

    1991-01-01

    The results of NPP Krsko core thermal power design limits investigation, which set bounds to the maximum allowable fuel temperature during normal operation and incidents of moderate frequency, are presented. In addition, allowable reactor coolant temperatures limited by the pressure of the steam generator safety valves opening are calculated. The range of a PWR plant safe operation imposed by the thermal overpower, the steam generator safety valves opening and DNBR safety limits is determined. (author)

  7. Fire experiences: principal lessons learned, application in PWR power plants

    International Nuclear Information System (INIS)

    Schoemacker, M.

    1984-01-01

    The article reviews the principal design rules to be borne in mind for PWR nuclear units installation. These rule takes into account: the specific character of materials involved (safety aspect for nuclear construction), experience acquired as a result of fires in EDF production units, and the results obtained from tests carried out by the EDF at Fort de Chelles between 1980 and 1982, especially in the field of PVC cables [fr

  8. Radiation release characterization of PWR spent fuel assemblies generated from Korean nuclear power plants

    Directory of Open Access Journals (Sweden)

    Moon Hyun Joo

    2009-01-01

    Full Text Available Spent nuclear fuel should be kept under safe management until it is disposed of permanently. Because of this, it is important to understand its radiation release characteristics. In this paper, the Monte Carlo method is applied to evaluate the radiation release characteristics of two types of PWR spent fuel assembly generated from the operating plants in Korea: Westinghouse and Korea Standard Nuclear Power Plant. The source terms were calculated using ORIGEN-ARP. The neutron and photon (or gamma dose distributions along the vertical and horizontal directions of each spent fuel assembly were evaluated using MCNPX code. Compared with the two dose distributions, the photon dose was found to be about 105 times higher than the neutron dose.

  9. Assessment of the insertion of reprocessed fuel spiked with thorium in a PWR core

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Victor F.; Monteiro, Fabiana B.A.; Pereira, Claubia, E-mail: victorfc@fis.grad.ufmg.br, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Reprocessed fuel by UREX+ technique and spiked with thorium was inserted in a PWR core and neutronic parameters have been analyzed. Based on the Final Safety Analysis Report (FSAR) of the Angra-2 reactor, the core was modeled and simulated with SCALE6.0 package. The neutronic data evaluation was carried out by the analysis of the effective and infinite multiplication factors, and the fuel evolution during the burnup. The conversion ratio (CR) was also evaluated. The results show that, when inserting reprocessed fuel spiked with thorium, the insertion of burnable poison rods is not necessary, due to the amount of absorber isotopes present in the fuel. Besides, the conversion ratio obtained was greater than the presented by standard UO{sub 2} fuel, indicating the possibility of extending the burnup. (author)

  10. Evaluation of full MOX core capability for a 900 MWe PWR

    International Nuclear Information System (INIS)

    Joo, Hyung-Kook; Kim, Young-Jin; Jung, Hyung-Guk; Kim, Young-Il; Sohn, Dong-Seong

    1996-01-01

    Full MOX capability of a PWR core with 900 MWe capacity has been evaluated in view of plutonium consumption and design feasibility as an effective means for spent fuel management. Three full MOX cores have been conceptually designed; for annual cycle, for 18-month cycle, and for 18-month cycle with high moderation lattice. Fissile and total plutonium quantities at discharge are significantly reduced to 60% and 70% respectively of initial value for standard full MOX cores. It is estimated that one full MOX core demands about 1 tonne of plutonium per year to be reloaded, which is equivalent to reprocessing of spent nuclear fuels discharged from five nuclear reactors operating with uranium fuels. With low-leakage loading scheme, a full MOX core with either annual or 18-month cycle can be designed satisfactorily by installing additional rod cluster control system and modifying soluble boron system. Overall high moderation lattice case promises better core nuclear characteristics. (author)

  11. PWR design for low doses in the United Kingdom: The present and the future

    Energy Technology Data Exchange (ETDEWEB)

    Zodiates, A.M.; Willcock, A. [PWR Project Group, Knutsford, England (United Kingdom)

    1995-03-01

    The Pressurizer Water Reactor (PWR) design chosen for adoption by Nuclear Electric plc was based on the Westinghouse Standard Nuclear Unit Power Plant System (SNUPPS). This design was developed to meet the United Kingdom (UK) requirements and those improvements are embodied in the Sizewell B plant. Nuclear Electric plc is now looking to the design of the future PWRs to be built in the UK. These PWRs will be based as replicas of the Sizewell B design, but attention will be given to reducing operator doses further. This paper details the approach in operator protection improvements incorporated at Sizewall B, presents the estimated annual collective dose, and identifies the approach being adopted to reduce further operator doses in future plants.

  12. PWR's countermeasures after Fukushima Daiichi Nuclear Power Plant accident

    International Nuclear Information System (INIS)

    Kato, Akihiko

    2012-01-01

    Countermeasures in case of similar events (loss of all AC power sources (SBO) and loss of ultimate heat sink (LUHS) as Fukushima Daiichi were investigated for further improvement of safety and reliability of PWR Plants. As for PWR in case of SBO and LUHS, steam driven auxiliary feedwater pump could be operable to supply feedwater to steam generators and stable state of reactor could be attained by natural circulation cooling of primary coolant Generated steam would be released to the air from main steam relief valve. Emergency safety countermeasures were taken to (1) improve water tightness by application of door and pipe penetration sealing to protect important equipment from flooding due to tsunami, (2) deploy mobile engine-operated pumps and (3) deploy emergency air-cooled generators. The government ordered 'stress tests' to quantify the effectiveness of safety measures for all Japan's reactors before they restart following any shutdown. Based on emergency safety countermeasures, plant operators assessed whether reactor and spent fuel pool could be stably cooled by external events (earthquake, tsunami and simultaneous effects) beyond the plant design basis. Further safety and reliability improvements of PWR plants had been considered or implemented for reinforcement of external power system, onsite power system with additional installation of permanent emergency air-cooled generators, enhancement of plant cooling function and update closure function of containment vessel in case of severe accident (T. Tanaka)

  13. Actinides transmutation - a comparison of results for PWR benchmark

    International Nuclear Information System (INIS)

    Claro, Luiz H.

    2009-01-01

    The physical aspects involved in the Partitioning and Transmutation (P and T) of minor actinides (MA) and fission products (FP) generated by reactors PWR are of great interest in the nuclear industry. Besides these the reduction in the storage of radioactive wastes are related with the acceptability of the nuclear electric power. From the several concepts for partitioning and transmutation suggested in literature, one of them involves PWR reactors to burn the fuel containing plutonium and minor actinides reprocessed of UO 2 used in previous stages. In this work are presented the results of the calculations of a benchmark in P and T carried with WIMSD5B program using its new cross sections library generated from the ENDF-B-VII and the comparison with the results published in literature by other calculations. For comparison, was used the benchmark transmutation concept based in a typical PWR cell and the analyzed results were the k∞ and the atomic density of the isotopes Np-239, Pu-241, Pu-242 and Am-242m, as function of burnup considering discharge of 50 GWd/tHM. (author)

  14. Evaluation of zinc addition to PWR primary coolant

    International Nuclear Information System (INIS)

    Pathania, R.; Yagnik, S.; Gold, R.E.; Dove, M.; Kolstad, E.

    1995-01-01

    Laboratory studies have shown that addition of zinc to a PWR environment reduces the general corrosion rates of materials in the primary system and delays the initiation of primary water stress corrosion cracking (PWSCC) in Alloy 600. Because of the potential benefits of zinc addition in reducing radiation fields and mitigating PWSCC of Alloy 600 a project was initiated to qualify zinc addition to a PWR. The objective of this work was to evaluate the effect of zinc addition on radiation fields, PWSCC of Alloy 600 and fuel cladding corrosion at the Farley-2 PWR. In order to provide an early warning of any potential adverse effects on the fuel cladding, corrosion studies were initiated at the Halden test reactor prior to zinc addition at Farley-2. This paper provides an overview of the scope of the zinc addition demonstration at Farley-2 and the fuel cladding corrosion tests at Halden. The zinc concentration in the Farley-2 coolant is approximately 40 ppb and that in Halden is 50 ppb. The paper presents initial results from these studies which are still in progress

  15. A scheme of better utilization of PWR spent fuels

    International Nuclear Information System (INIS)

    Chung, Bum Jin; Kang, Chang Soon

    1991-01-01

    The recycle of PWR spent fuels in a CANDU reactor, so called the tandem fuel cycle is investigated in this study. This scheme of utilizing PWR spent fuels will ease the shortage of spent fuel storage capacity as well as will improve the use of uranium resources. The minimum modification the design of present CANDU reactor is seeked in the recycle. Nine different fuel types are considered in this work and are classified into two categories: refabrication and reconfiguration. For refabrication, PWR spent fuels are processed and refabricated into the present 37 rod lattice structure of fuel bundle, and for reconfiguration, meanwhile, spent fuels are simply disassembled and rods are cut to fit into the present grid configuration of fuel bundle without refabrication. For each fuel option, the neutronics calculation of lattice was conducted to evaluate the allowable burn up and distribution. The fuel cycle cost of each option was also computed to assess the economic justification. The results show that most tandem fuel cycle option considered in this study are technically feasible as well as economically viable. (Author)

  16. FLUOLE-2: An Experiment for PWR Pressure Vessel Surveillance

    Directory of Open Access Journals (Sweden)

    Thiollay Nicolas

    2016-01-01

    Full Text Available FLUOLE-2 is a benchmark-type experiment dedicated to 900 and 1450 MWe PWR vessels surveillance dosimetry. This two-year program started in 2014 and will end in 2015. It will provide precise experimental data for the validation of the neutron spectrum propagation calculation from core to vessel. It is composed of a square core surrounded by a stainless steel baffe and internals: PWR barrel is simulated by steel structures leading to different steel-water slides; two steel components stand for a surveillance capsule holder and for a part of the pressure vessel. Measurement locations are available on the whole experimental structure. The experimental knowledge of core sources will be obtained by integral gamma scanning measurements directly on fuel pins. Reaction rates measured by calibrated fission chambers and a large set of dosimeters will give information on the neutron energy and spatial distributions. Due to the low level neutron flux of EOLE ZPR a special, high efficiency, calibrated gamma spectrometry device will be used for some dosimeters, allowing to measure an activity as low as 7. 10−2 Bq per sample. 103mRh activities will be measured on an absolute calibrated X spectrometry device. FLUOLE-2 experiment goal is to usefully complete the current experimental benchmarks database used for the validation of neutron calculation codes. This two-year program completes the initial FLUOLE program held in 2006–2007 in a geometry representative of 1300 MWe PWR.

  17. PWR fuel pin diameter optimisation studies and economic analyses for uranium nitride fuel - 5048

    International Nuclear Information System (INIS)

    Thomas, G.M.; Grove, C.

    2015-01-01

    Alternative advanced fuels are currently being investigated by the nuclear industry. For example, research is underway into the possibility of replacing industry standard UO 2 fuel with Accident Tolerant Fuels (ATF) such as uranium nitride (UN). The higher density of UN compared with UO 2 results in a reduction in neutron moderation due to the lower hydrogen to heavy metal ratio (H/HM) for a given fuel assembly geometry in water. This suggests a different optimum UN fuel pin diameter in order to maximise lifetime average reactivity. If a smaller UN pellet/cladding diameter is adopted then the H/HM ratio is increased, leading to an increase in reactivity at lower burnup (followed by a reduction at higher burnup due to reduced Pu production). Preliminary studies have also indicated that a reduction of the UN pellet diameter with respect to standard UO 2 fuel could be beneficial to economic performance. This paper describes an approach used to determine the optimum fuel pin diameter for UN fuel in an AP1000 PWR using Studsvik CASMO4/SIMULATE3 neutronics codes. The objective is to maximise the fuel's lifetime average reactivity while staying within typical PWR nuclear design safety limits. The calculations demonstrate that the pin diameter should be decreased to optimise the fuel reactivity. However, if the pin diameter is decreased too much a highly undesirable positive moderator temperature coefficient can result. Economics calculations show that if UN fuel is used there is a potential economic benefit - in the region of 3 million dollar per 18-month reload if generic openly available cost data is used

  18. Hydro mechanical investigation on different PWR upper plenum core structures

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Yu Ping'an; Yang Guanyue

    1997-01-01

    The development of Nuclear Industry relys on the safe and reliable operation of nuclear power station. Whether or not control rods moving upward and downward freedly and dropping rapidly in emergency case by order directly dominates the nuclear power regulation and emergency shut-down. So to clarify the factors which exert great influences on the drop of control rods is very important for making certain that PWR is operated safety and relialy. Among the factors, the hydraulic load on the control rods plays an important role during the operation of reactor. However because of complication in turbulent flow and concentration of the control rod guide bundles in the upper plenum, the flow field has not been thoroughly studied up to now. In order to understand the flow field in upper plenum fully a 1/4 scale transparent model of the upper plenum of a active 300 MWe PWR is designed and installed in line with similarity theory. The velocity distributions (including horizontal and axial velocity) in the upper plenum are obtained by using N-J type Dynamic Resistance Strain Foil Velocimetry (N-J type DRSFV) and Laser Doppler Velocimetry (LDV). For the sake of alleviating the hydraulic load on the control rods and making certain that the control rods and making certain that the control rods are moving upward and downward freely and drop rapidly in emergency case by order, the core structure in the upper plenum of the active 300 MWe PWR is improved as in the following 2 cases: 1 Some protective sleeves are added to the control rod guide bundles near the upper plenum outlet nozzles (symmetric 4 bundles: 02-26, 03-25, 11-29, 12-28). The rest of the core structure is same as that of the core structure in the active 300 MWe PWR. 2. The active upper plenum core structure with 37 control rod guide bundles is replaced by the core structure with 33 protective-sleeved control rod guide bundles. The results of the simulated experiments with the 2 cases are compared with that of the

  19. PSA LEVEL 3 DAN IMPLEMENTASINYA PADA KAJIAN KESELAMATAN PWR

    Directory of Open Access Journals (Sweden)

    Pande Made Udiyani

    2015-03-01

    Full Text Available Kajian keselamatan PLTN menggunakan metodologi kajian probabilistik sangat penting selain kajian deterministik. Metodologi kajian menggunakan Probabilistic Safety Assessment (PSA Level 3 diperlukan terutama untuk estimasi kecelakaan parah atau kecelakaan luar dasar desain PLTN. Metode ini banyak dilakukan setelah kejadian kecelakaan Fukushima. Dalam penelitian ini dilakukan implementasi PSA Level 3 pada kajian keselamatan PWR, postulasi kecelakan luar dasar desain PWR AP-1000 dan disimulasikan di contoh tapak Bangka Barat. Rangkaian perhitungan yang dilakukan adalah: menghitung suku sumber dari kegagalan teras yang terjadi, pemodelan kondisi meteorologi tapak dan lingkungan, pemodelan jalur paparan, analisis dispersi radionuklida dan transportasi fenomena di lingkungan, analisis deposisi radionuklida, analisis dosis radiasi, analisis perlindungan & mitigasi, dan analisis risiko. Kajian menggunakan rangkaian subsistem pada perangkat lunak PC Cosyma. Hasil penelitian membuktikan bahwa implementasi metode kajian keselamatan PSA Level 3 sangat efektif dan komprehensif terhadap estimasi dampak, konsekuensi, risiko, kesiapsiagaan kedaruratan nuklir (nuclear emergency preparedness, dan manajemen kecelakaan reaktor terutama untuk kecelakaan parah atau kecelakaan luar dasar desain PLTN. Hasil kajian dapat digunakan sebagai umpan balik untuk kajian keselamatan PSA Level 1 dan PSA Level 2. Kata kunci: PSA level 3, kecelakaan, PWR   Reactor safety assessment of nuclear power plants using probabilistic assessment methodology is most important in addition to the deterministic assessment. The methodology of Level 3 Probabilistic Safety Assessment (PSA is especially required to estimate severe accident or beyond design basis accidents of nuclear power plants. This method is carried out after the Fukushima accident. In this research, the postulations beyond design basis accidentsof PWR AP - 1000 would be taken, and simulated at West Bangka sample site. The

  20. RCC-C: Design and construction rules for fuel assemblies of PWR nuclear power plants

    International Nuclear Information System (INIS)

    2015-01-01

    The RCC-C code contains all the requirements for the design, fabrication and inspection of nuclear fuel assemblies and the different types of core components (rod cluster control assemblies, burnable poison rod assemblies, primary and secondary source assemblies and thimble plug assemblies). The design, fabrication and inspection rules defined in RCC-C leverage the results of the research and development work pioneered in France, Europe and worldwide, and which have been successfully used by industry to design and build nuclear fuel assemblies and incorporate the resulting feedback. The code's scope covers: fuel system design, especially for assemblies, the fuel rod and associated core components, the characteristics to be checked for products and parts, fabrication methods and associated inspection methods. The RCC-C code is used by the operator of the PWR nuclear power plants in France as a reference when sourcing fuel from the world's top two suppliers in the PWR market, given that the French operator is the world's largest buyer of PWR fuel. Fuel for EPR projects is manufactured according to the provisions of the RCC-C code. The code is available in French and English. The 2005 edition has been translated into Chinese. Contents of the 2015 edition of the RCC-C code: Chapter 1 - General provisions: 1.1 Purpose of the RCC-C, 1.2 Definitions, 1.3 Applicable standards, 1.4 Equipment subject to the RCC-C, 1.5 Management system, 1.6 Processing of non-conformances; Chapter 2 - Description of the equipment subject to the RCC-C: 2.1 Fuel assembly, 2.2 Core components; Chapter 3 - Design: Safety functions, operating functions and environment of fuel assemblies and core components, design and safety principles; Chapter 4 - Manufacturing: 4.1 Materials and part characteristics, 4.2 Assembly requirements, 4.3 Manufacturing and inspection processes, 4.4 Inspection methods, 4.5 Certification of NDT inspectors, 4.6 Characteristics to be inspected for the

  1. Analysis of mechanisms induced by sliding and corrosion: dedicated apparatus for PWR environments

    International Nuclear Information System (INIS)

    Vernot, JPh

    2004-01-01

    In pressurized water reactors (PWR), some components are submitted to relative motions due to necessary operational processes (localisation and positioning adjustment) or by not wished effects (flow induced vibration). Thus, components and associated supports are typically excited by a large range of kinematics so than complex combinations of wear can occur. Those excitations can lead to sliding, fretting, impact, etc. Furthermore, typical environment in PWR coupling of temperature (320 deg. C), pressure (154 bars) and chemistry solution (deaerated, low conductivity water) involve specific corrosion processes. Apparently, research performed to date did not deal with all the specific parameters involved at PWR conditions. For this purpose, a specific apparatus has been developed in Framatome Technical Center for a better understanding of this complex degradation mechanism where mechanical and corrosion effects are occurring at the same time. Thanks to electromagnets excitation, mechanical investigations can be proposed with the following combined contact type: pure impact, pure sliding and impact plus sliding for several kinds of sample as rod in a ring, rod against a guide. Motion can be induced on a local area or for the total length (orbital excitation). The relative displacement and the contact force are acquired continuously and permit to establish normal and tangential forces, angular position, sliding distance. On the other hand, electrochemistry measurements have been adapted to the specific apparatus and work in the high temperature water environment. The standard mounting with three electrodes has been qualified so that it is possible to adjust or measure current and potential. All the system is computer controlled and with the present apparatus relationship between mechanical parameters and re-passivation can be studied for specific environments, materials and solicitations. In a first step, potential dynamic polarization curves have been established for

  2. Numerical Experiments of Coolant Mixing in a Lower Plenum of PWR Under Asymmetric Thermal- Hydraulics Conditions

    International Nuclear Information System (INIS)

    Masanori Ohtani; Akito Kozuru; Yasuyuki Kashimoto; Mitsuto Montani; Koutaro Takeda; Yasushi Makino

    2006-01-01

    Asymmetric thermal-hydraulic conditions among primary loops during a postulated steam line break (SLB) induce a non-uniform temperature distribution at a core inlet. When coolant of lower temperature intrudes into a part of core, it leads to a reactivity insertion and a local power increase. Therefore, an appropriate model for the core inlet temperature distribution is required for a realistic SLB analysis. In this study, numerical experiments were conducted to examine the core inlet temperature distribution under the asymmetric thermal-hydraulic coolant conditions among primary loops. 3D steady-state calculations were carried out for Japanese standard Pressurized Water Reactor (PWR) such as 2, 3, 4 loop types and an advanced PWR. Since the flow in a reactor vessel involves time-dependent velocity fluctuations due to a high Reynolds number condition and a complicated geometry of flow path, the turbulent mixing might be enhanced. Hence, the turbulent thermal diffusivity for the steady-state calculation was examined based on experimental results and another transient calculation. As a result, it was confirmed that (1) the turbulent mixing in a downcomer and a lower plenum were enhanced due to time-dependent velocity fluctuations and therefore the turbulent thermal diffusivity for steady-state calculation was specified to be greater, (2) the core inlet temperature distribution predicted by a steady-state calculation reasonably agreed with a experimental data, (3) the patterns of core inlet temperature distribution were comprehended to be dependent on the plant type, i.e. the number of primary loop and (4) under a low flow rate condition, the coolant of lower temperature appeared on the opposite side of the affected loop due to the effect of a natural convection. (authors)

  3. Design development of steel plate concrete modularization for the advanced PWR in Korea

    International Nuclear Information System (INIS)

    Mun, Taeyoup; Kim, Keunkyeong; Sun, Wonsang; Kim, Taeyoung; Hwang, Geunha

    2008-01-01

    APR1400 TM - an advanced PWR - has been developed in Korea since 1992. Four APR1400 units - Shin Kori no.3,4 and Shin Uljin no.1,2 - are going to be built in a next decade. As for economical efficiency, construction cost per power generation Unit(W) is improved more than 10% compared to the former 1,000 MWe PWRs. Moreover, life-cycle maintenance cost is reduced to the world's most level. For construction period from first concrete pouring to commercial operation, 54 months for APR1400 and 36 months for n-th unit have been projected. Reduction of the construction term of the Nuclear Power Plant has been emphasized increasingly for the NPP construction Project because it would reduce the interest cost and uncertainty of the project. The reduction can also advance the return of investment. Some of the PPM(Prefabrication, Preassembly, and Modularization) techniques have been studied for the shortening the construction period of nuclear power plant. Especially for the internal structure of reactor containment building (RCB) in PWR whose term of construction is critical to the whole project, Steel Plate Concrete(SC) structure has been studied as one of alternative structural systems to the conventional Reinforced Concrete(RC) structure in APR1400. SC structure is considered appropriate for the modularization of the structure with its self-supporting. In addition, formwork can be dramatically eliminated when SC structural modules are used. The MKE (Ministry of Knowledge Economy) and KHNP (Korea Hydro and Nuclear Power Co., Ltd.) initiated the research and development of SC Structure in 2005. This paper presents design examples along with Codes and Standards of SC structure in nuclear power plant. (author)

  4. Study of power peak migration due to insertion of control bars in a PWR reactor

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Costa, Danilo Leite; Borges, Diogo da Silva; Lava, Deise Diana; Lima, Zelmo Rodrigues de; Moreira, Maria de Lourdes

    2014-01-01

    This paper aims to present a study on the power distribution behavior in a PWR reactor, considering the intensity and the migration of power peaks as is the insertion of control rods in the core banks. For this, the study of the diffusion of neutrons in the reactor was adopted by computer simulation that uses the finite difference method for numerically solving the neutron diffusion equation to two energy groups in steady state and in symmetry of a fourth quarter core. We decided to add the EPRI-9R 3D benchmark thermal-hydraulic parameters of a typical power PWR. With a new configuration for the reactor, the positions of the control rods banks were also modified. Due to the new positioning of these banks in the reactor, there was intense power gradients, favoring the occurrence of critical situations and logically unconventional for operation of a nuclear reactor. However, these facts have led interesting times for the study on the power distribution behavior in the reactor, showing axial migration of power peaks and mainly the effect of the geometry of the core on the latter. Based on the distribution of power was evident the increase of the power in elements located in the central region of the reactor core and, concomitantly, the reduction in elements of its periphery. Of course, the behavior exhibited by the simulated reactor is not in agreement with that expected in an actual reactor, where the insertion of control rods banks should lead to reduced power throughout the core as evenly as possible, avoiding sharp power peaks, standardizing the burning fuel, controlling reactivity deviations and acting in reactor shutdown

  5. Thermal hydraulic design of a hydride-fueled inverted PWR core

    International Nuclear Information System (INIS)

    Malen, J.A.; Todreas, N.E.; Hejzlar, P.; Ferroni, P.; Bergles, A.

    2009-01-01

    An inverted PWR core design utilizing U(45%, w/o)ZrH 1.6 fuel (here referred to as U-ZrH 1.6 ) is proposed and its thermal hydraulic performance is compared to that of a standard rod bundle core design also fueled with U-ZrH 1.6 . The inverted design features circular cooling channels surrounded by prisms of fuel. Hence the relative position of coolant and fuel is inverted with respect to the standard rod bundle design. Inverted core designs with and without twisted tape inserts, used to enhance critical heat flux, were analyzed. It was found that higher power and longer cycle length can be concurrently achieved by the inverted core with twisted tape relative to the optimal standard core, provided that higher core pressure drop can be accommodated. The optimal power of the inverted design with twisted tape is 6869 MW t , which is 135% of the optimally powered standard design (5080 MW t -determined herein). Uncertainties in this design regarding fuel and clad dimensions needed to accommodate mechanical loads and fuel swelling are presented. If mechanical and neutronic feasibility of these designs can be confirmed, these thermal assessments imply significant economic advantages for inverted core designs.

  6. Safety aspects of the using Gd as burnable poison in PWR's

    International Nuclear Information System (INIS)

    Vandenberg, C.; Bonet, H.; Charlier, A.

    1978-01-01

    The experience of BELGONUCLEAIRE in using Gd in LWR's has indicated the safety related advantages of this burnable poison. The successfully operation of the BR3 PWR power plant with 5% of Gd rods is presented and extrapolated to large PWR's. (authro)

  7. MOX and UOX PWR fuel performances EDF operating experience

    International Nuclear Information System (INIS)

    Provost, Jean-Luc; Debes, Michel

    2005-01-01

    Based on a large program of experimentations implemented during the 90s, the industrial achievement of new FAs designs with increased performances opens up new prospects. The currently UOX fuels used on the 58 EDF PWR units are now authorized up to a maximum FA burn-up of 52 GWd/t with a large experience from 45 to 50 GWd/t. Today, the new products, along with the progress made in the field of calculation methods, still enable to increase further the fuel performances with respect to the safety margins. Thus, the conditions are met to implement in the next years new fuel managements on each NPPs series of the EDF fleet with increased enrichment (up to 4.5%) and irradiation limits (up to 62 GWd/t). The recycling of plutonium is part of EDF's reprocessing/recycling strategy. Up to now, 20 PWR 900 MW reactors are managed in MOX hybrid management. The feedback experience of 18 years of PWR operation with MOX is satisfactory, without any specific problem regarding manoeuvrability or plant availability. EDF is now looking to introduce MOX fuels with a higher plutonium content (up to 8.6%) equivalent to natural uranium enriched to 3.7%. It is the goal of the MOX Parity core management which achieve balance of MOX and UOX fuel performance with a significant increase of the MOX average discharge burn-up (BU max: 52 GWd/t for MOX and UOX). The industrial maturity of new FAs designs, with increased performances, allows the implementation in the next years of new fuel managements on each NPPs series of the EDF fleet. The scheduling of the implementation of the new fuel managements on the PWRs fleet is a great challenge for EDF, with important stakes: the nuclear KWh cost decrease with the improvement of the plant operation performance. (author)

  8. BWR and PWR chemistry operating experience and perspectives

    International Nuclear Information System (INIS)

    Fruzzetti, K.; Garcia, S.; Lynch, N.; Reid, R.

    2014-01-01

    It is well recognized that proper control of water chemistry plays a critical role in ensuring the safe and reliable operation of Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). State-of-the-art water chemistry programs reduce general and localized corrosion of reactor coolant system, steam cycle equipment, and fuel cladding materials; ensure continued integrity of cycle components; and reduce radiation fields. Once a particular nuclear plant component has been installed or plant system constructed, proper water chemistry provides a global tool to mitigate materials degradation problems, thereby reducing the need for costly repairs or replacements. Recognizing the importance of proper chemistry control and the value in understanding the relationship between chemistry guidance and actual operating experience, EPRI continues to collect, monitor, and evaluate operating data from BWRs and PWRs around the world. More than 900 cycles of valuable BWR and PWR operating chemistry data has been collected, including online, startup and shutdown chemistry data over more than 10 years (> 20 years for BWRs). This paper will provide an overview of current trends in BWR and PWR chemistry, focusing on plants in the U.S.. Important chemistry parameters will be highlighted and discussed in the context of the EPRI Water Chemistry Guidelines requirements (i.e., those parameters considered to be of key importance as related to the major goals identified in the EPRI Guidelines: materials integrity; fuel integrity; and minimizing plant radiation fields). Perspectives will be provided in light of recent industry initiatives and changes in the EPRI BWR and PWR Water Chemistry Guidelines. (author)

  9. Plutonium recycle in PWR reactors (Brazilian Nuclear Program)

    International Nuclear Information System (INIS)

    Rubini, L.A.

    1978-02-01

    An evaluation is made of the material requirements of the nuclear fuel cycle with plutonium recycle. It starts from the calculation of a reference reactor and allows the evaluation of demand under two alternatives of nuclear fuel cycle for Pressurized Water Reactors (PWR): without plutonium recycle; and with plutonium recycle. Calculations of the reference reactor have been carried out with the CELL-CORE codes. For plutonium recycle, the concept of uranium and plutonium homogeneous mixture has been adopted, using self-produced plutonium at equilibrium, in order to get minimum neutronic perturbations in the reactor core. The refueling model studied in the reference reactor was the 'out-in' scheme with a constant number of changed fuel elements (approximately 1/3 of the core). Variations in the material requirements were studied considering changes in the installed nuclear capacity of PWR reactors, the capacity factor of these reactors, and the introduction of fast breeders. Recycling plutonium produced inside the system can reach economies of about 5%U 3 O 8 and 6% separative work units if recycle is assumed only after the 5th operation cycle of the thermal reactors. The cumulative amount of fissile plutonium obtained by the Brazilian Nuclear Program of PWR reactors by 1991 should be sufficient for a fast breeder with the same capacity as Angra 2. For the proposed fast breeder programs, the fissile plutonium produced by thermal reactors is sufficient to supply fast breeder initial necessities. Howewer, U 3 O 8 and SWU economy with recycle is not significant when the proposed fast breeder program is considered. (Author) [pt

  10. Study of the distribution of hydrogen in a PWR containment with CFD codes; Estudio de la distribucion de hidrogeno en una contencion PWR con codigos CFD

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, G.; Matias, R.; Fernandez, K.; Justo, D.; Bocanegra, R.; Mena, L.; Queral, C.

    2015-07-01

    During a severe accident in a PWR, the hydrogen generated may be distributed in the containment atmosphere and reach the combustion conditions that can cause the containment failure. In this research project, a preliminary study has been done about the capacities of ANSYS Fluent 15.0 and GOTHIC 8.0 to tri dimensional distribution of the hydrogen in a PWR containment during a severe accident. (Author)

  11. Estimating probable flaw distributions in PWR steam generator tubes

    International Nuclear Information System (INIS)

    Gorman, J.A.; Turner, A.P.L.

    1997-01-01

    This paper describes methods for estimating the number and size distributions of flaws of various types in PWR steam generator tubes. These estimates are needed when calculating the probable primary to secondary leakage through steam generator tubes under postulated accidents such as severe core accidents and steam line breaks. The paper describes methods for two types of predictions: (1) the numbers of tubes with detectable flaws of various types as a function of time, and (2) the distributions in size of these flaws. Results are provided for hypothetical severely affected, moderately affected and lightly affected units. Discussion is provided regarding uncertainties and assumptions in the data and analyses

  12. Natural-circulation-cooling characteristics during PWR accident simulations

    International Nuclear Information System (INIS)

    Adams, J.P.; McCreery, G.E.; Berta, V.T.

    1983-01-01

    A description of natural circulation cooling characteristics is presented. Data were obtained from several pressurized water reactor accident simulations in the Loss-of-Fluid Test (LOFT) pressurized water reactor (PWR). The reliability of natural circulation cooling, its cooling effectiveness, and the effect of changing system conditions are described. Quantitative comparison of flow rates and time constants with theory for both single- and two-phase fluid conditions were made. It is concluded that natural circulation cooling can be relied on in plant recovery procedures in the absence of forced convection whenever the steam generator heat sink is available

  13. Conversion ratio in epithermal PWR, in thorium and uranium cycle

    International Nuclear Information System (INIS)

    Barroso, D.E.G.

    1982-01-01

    Results obtained for the conversion ratio in PWR reactors with close lattices, operating in thorium and uranium cycles, are presented. The study of those reactors is done in an unitary fuel cell of the lattices with several ratios V sub(M)/V sub(F), considering only the equilibrium cycles and adopting a non-spatial depletion calculation model, aiming to simulate mass flux of reactor heavy elements in the reactor. The neutronic analysis and the cross sections generation are done with Hammer computer code, with one critical apreciation about the application of this code in epithermal systems and with modifications introduced in the library of basic data. (E.G.) [pt

  14. Sizewell B - analysis of British application of US PWR technology

    International Nuclear Information System (INIS)

    1983-05-01

    This report provides information on the staff's evaluation of major design differences and issues developed by the British in their application (Sizewell B) of US PWR technology. One design change, the addition of steam-driven charging pumps, was assessed to have a relatively high value compared to the other changes. However, the assessment is based on a number of assumptions for which inadequate data exist to make an unqualified judgment. Other changes to the US design (as typified by the SNUPPS design) were found to have relatively low or moderate safety benefits for US application

  15. Modelling local chemistry in PWR steam generator crevices

    International Nuclear Information System (INIS)

    The accumulation of impurities in local regions of PWR Steam Generators (SG) has resulted in the accelerated corrosion of SG materials. The chemical conditions in crevices and sludge piles is dependent on thermal hydraulic and mass transfer processes as well as the physical chemistry of the concentrated solution itself. This paper discusses the different modelling approaches which can be used to describe the concentration process and the local chemistry in these regions. The limitations of each approach and the applicability of model results to field conditions are discussed in the paper. EPRI's program in this area, including past accomplishments and the models used in the MULTEQ code are described in the paper. (author)

  16. Conversion ratio and consumption of fissile material in PWR reactors

    International Nuclear Information System (INIS)

    Tiba, C.

    1977-01-01

    It has been shown that the uranium resources will be insufficient for future projected demand. The many solutions to this problem are considered and, in particular, the effect of enrichment on the conversion ratio and hence total uranium comsumption is studied. The developed computacional method employs the one-group neutron diffusion theory. The model is verified by calculating typical burn-up, conversion ratio, U-235 comsumption and plutonium production values in PWR's, and comparing results with those in the published literature. The associated costs of U and U-Pu fuel cycles are also studied for various enrichment values [pt

  17. Model for calculating the boron concentration in PWR type reactors

    International Nuclear Information System (INIS)

    Reis Martins Junior, L.L. dos; Vanni, E.A.

    1986-01-01

    A PWR boron concentration model has been developed for use with RETRAN code. The concentration model calculates the boron mass balance in the primary circuit as the injected boron mixes and is transported through the same circuit. RETRAN control blocks are used to calculate the boron concentration in fluid volumes during steady-state and transient conditions. The boron reactivity worth is obtained from the core concentration and used in RETRAN point kinetics model. A FSAR type analysis of a Steam Line Break Accident in Angra I plant was selected to test the model and the results obtained indicate a sucessfull performance. (Author) [pt

  18. Upper internals of PWR with coolant flow separator

    International Nuclear Information System (INIS)

    Chevereau, G.; Heuze, A.

    1989-01-01

    The upper internals for a PWR has a collecting volume for the coolant merging from the core and an apparatus for separating the flow of coolant. This apparatus has a guide for the control rods, a lower plate perforated to allow the coolant through from the core, an upper plate also perforated to allow the coolant through to the collecting volume and a peripheral binding ring joining the two plates. Each guide comprises an envelope without holes and joined perceptibly tight to the plates [fr

  19. A study on thimble plug removal for PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dong Soo; Lee, Chang Sup; Lee, Jae Yong; Jun, Hwang Yong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation. 8 refs., 5 tabs. (Author)

  20. Structure-dynamic model verification calculation of PWR 5 tests

    International Nuclear Information System (INIS)

    Engel, R.

    1980-02-01

    Within reactor safety research project RS 16 B of the German Federal Ministry of Research and Technology (BMFT), blowdown experiments are conducted at Battelle Institut e.V. Frankfurt/Main using a model reactor pressure vessel with a height of 11,2 m and internals corresponding to those in a PWR. In the present report the dynamic loading on the pressure vessel internals (upper perforated plate and barrel suspension) during the DWR 5 experiment are calculated by means of a vertical and horizontal dynamic model using the CESHOCK code. The equations of motion are resolved by direct integration. (orig./RW) [de

  1. Improvement in PWR flexibility the french program 1975-1995

    International Nuclear Information System (INIS)

    Gautier, A.; Miossec, C.

    1985-12-01

    Between 1975 and 1985, a substantial effort was launched in France to greatly improve PWR's flexibility, resulting in the current situation where both frequency control and load follow are now routinely performed on most plants in operation. Based on rapidly accumulating operational experience and on all expertise acquired in the past decade, a second-generation core control strategy is now being finalized for application on all future 1400 MW plants (with commercial operation scheduled in 1992 for first unit). This 20-year program is discussed

  2. New genetic algorithms (GA) to optimize PWR reactors

    International Nuclear Information System (INIS)

    Alim, Fatih; Ivanov, Kostadin; Levine, Samuel H.

    2008-01-01

    The objective of this study was to develop a unique scientific methodology as well as a practical tool for designing the loading pattern (LP) and burnable poison (BP) pattern for a given Pressurized Water Reactor (PWR) core. Because of the large number of possible combinations for the fuel assembly (FA) loading in the core, the design of the core configuration is a complex optimization problem. It requires finding an optimal FA arrangement and corresponding BP placement design that will achieve maximum cycle length while satisfying the safety constraints. To solve this optimization problem, a core reload optimization package, GARCO (Genetic Algorithm Reactor Code Optimization) code is developed. This code is applicable for all types of PWR cores having different geometries and designs with an unlimited number of FA types in the inventory. GARCO has three modes: the user can optimize the core configuration (LP pattern) with or without BPs in the first mode; the second mode is the optimization of BP placement in the core and the last mode is the user can optimize LP and BP placements simultaneously in mode 3. In this study, the first mode finds the optimal LPs using the Haling Power Depletion Method (HPD) for placing BPs in the core. The second mode, which depletes the core accurately, places BPs in the selected optimum LP pattern. This methodology is applied only to the TMI-1 PWR. However, the improved Mode 1 GA option was applied to both the VVER-1000 and the TMI-1 to demonstrate and verify the advantages of the new enhancements in optimizing the LP pattern only. The 'Moby-Dick' code is used as reactor physics code for VVER-1000 analysis in this research. The SIMULATE-3 code, which is an advanced two-group nodal code, is used to analyze the TMI-1. The libraries of the BP designs used in SIMULATE-3 in this study were produced by Yilmaz (2005) [Yilmaz, S., 2005. Multilevel optimization of burnable poison utilization for advanced PWR fuel management. Ph.D. Thesis in

  3. Fine numerical modelling of thermohydraulic phenomena in EDF PWR reactors

    International Nuclear Information System (INIS)

    Boulot, F.

    1993-01-01

    Over the last 20 years, EDF has developed a family of 2D and 3D industrial thermohydraulics software to solve problems encountered in existing PWR power plants and to design new reactors for the future. The equations used in the models are the averaged Navier-Stokes and energy equations. A brief description is given of the four main codes developed for single-phase and two-phase water-steam flows, some of which use finite differences or finite volumes methods, while others make use of finite elements methods. An example of application is given for each code. (author). 4 figs., 4 refs

  4. Electropolishing process development for PWR steam generator channel heads

    International Nuclear Information System (INIS)

    Asay, R.H.; Graves, P.; Guastaferro, C.T.; Spalaris, C.N.

    1991-04-01

    A broad range of process parameters was established to smoothen the surface of 309 L weld clad overlay, prototypic of surfaces common is channel heads of replacement PWR [pressurized water reactor] steam generators. Mechanical and electropolishing steps were studied to explore process boundaries, which result in acceptable degree of surface smoothness, without compromising metallurgical properties. Recommended processes and acceptance criteria established in this work, can be applied to electropolish steam generator channel heads. Smooth surfaces are less likely to retain radioactive species, and potentially develop lower radiation fields when these components are placed into service. 7 refs., 11 figs., 12 tabs

  5. Chemical cleaning of PWR steam generators: application at Nogent 1

    International Nuclear Information System (INIS)

    Fiquet, J.M.; Veysset, J.P.; Esteban, L.; Saurin, P.

    1990-01-01

    EDF has developed and patented a chemical cleaning process for PWR steam generators, based on the use of a mixture of organic acids in order to: - dissolve iron oxides and copper with a single solution; - clean dented crevices. Qualification tests have permitted to demonstrate effectiveness of the solution and its inocuousness related to steam generator materials. The process, the license of which belongs to SOMAFER R.A. and FRAMATOME, has been implemented in France at Nogent. The goal was to dissolve iron oxides allowing metallic particles, aggregated on the tubesheet, to be released and mechanically removed. The effectiveness was satisfactory and this treatment is to be extended to other units [fr

  6. Thermal-hydraulic analysis of PWR cores in transient condition

    International Nuclear Information System (INIS)

    Silva Galetti, M.R. da.

    1984-01-01

    A calculational methodology for thermal - hydraulic analysis of PWR cores under steady-state and transient condition was selected and made available to users. An evaluation of the COBRA-IIIP/MIT code, used for subchannel analysis, was done through comparison of the code results with experimental data on steady state and transient conditions. As a result, a comparison study allowing spatial and temporal localization of critical heat flux was obtained. A sensitivity study of the simulation model to variations in some empirically determined parameter is also presented. Two transient cases from Angra I FSAR were analysed, showing the evolution of minimum DNBR with time. (Author) [pt

  7. Modelling of pellet-cladding interaction in PWR's

    International Nuclear Information System (INIS)

    Esteves, A.M.; Silva, A.T. e.

    1992-01-01

    The pellet-cladding interaction that can occur in a PWR fuel rod design is modelled with the computer codes FRAPCON-1 and ANSYS. The fuel performance code FRAPCON-1 analyses the fuel rod irradiation behavior and generates the initial conditions for the localized fuel rod thermal and mechanical modelling in two and three-dimensional finite elements with ANSYS. In the mechanical modelling, a pellet fragment is placed in the fuel rod gap. Two types of fuel rod cladding materials are considered: Zircaloy and austenitic stainless steel. (author)

  8. The N4 plant: culmination of French PWR experience

    International Nuclear Information System (INIS)

    Bellet, J.; Houyez, A.; Journet, J.; Pierrard, J.H.

    1985-01-01

    The model N4 series of 1400MWe class PWR plants has been developed in France from a unique base of technical and operating experience. It meets the French government's requirement for a reactor free of constraints due to licensing agreements with overseas companies, with enhanced safety features and incorporating the lessons of Three Mile Island. In particular, improvements have been made to the reactor vessel, the steam generators, the primary pumps and control systems. The units are capable of daily load following and extended operation between refuelling. The N4 plant includes a new design of turbine-generator. (author)

  9. Substitution of cobalt alloying in PWR primary circuit gate valves

    International Nuclear Information System (INIS)

    Cachon, L.; Sudreau, F.; Brunel, L.

    1995-01-01

    The object of this study is qualify cobalt-free alternative alloys for valve applications. This paper focus on tribological characterization of numerous coatings is done by using the first one, of a classical type. Then tests are performed with the second one which simulates solicitations supported by gate valves in primary circuit of PWR. 35% Ni-Cr - 65% Cr 3 C 2 coating, deposited by detonation gun technology, gives us hope to find a substitute of Stelite 6. (author). 5 refs., 16 figs., 2 tabs

  10. Vertical Drop Of 21-PWR Waste Package On Unyielding Surface

    International Nuclear Information System (INIS)

    S. Mastilovic; A. Scheider; S.M. Bennett

    2001-01-01

    The objective of this calculation is to determine the structural response of a 21-PWR (pressurized-water reactor) Waste Package (WP) subjected to the 2-m vertical drop on an unyielding surface at three different temperatures. The scope of this calculation is limited to reporting the calculation results in terms of stress intensities in two different WP components. The information provided by the sketches (Attachment I) is that of the potential design of the type of WP considered in this calculation, and all obtained results are valid for that design only

  11. New instrumentation of reactor water level for PWR; Nueva Instrumentacion de nivel de agua del reactor para PWR

    Energy Technology Data Exchange (ETDEWEB)

    Kaercher, S.

    2005-07-01

    Today, many PWR reactors are equipped with a reactor water level instrumentation system based on different measurement methods. Due to obsolescence issues, FRAMATOME ANP started to develop and quality a new water level measurement system using heated und unheated thermocouple measurements. the measuring principle is based on the fact that the heat transfer in water is considerably higher than in steam. The electronic cabinet for signal processing is based on a proven technology already developed, qualified and installed by FRAMATOME ANP in several NPPs. It is equipped with and advanced temperature measuring transducer for acquisition and processing of thermocouple signals. (Author)

  12. Gamma and Neutron Radiolysis in the 21-PWR Waste Package

    Energy Technology Data Exchange (ETDEWEB)

    J.S. Tang

    2001-05-03

    The objective of this calculation is to compute gamma and neutron dose rates in order to determine the maximum radiolytic production of nitric acid and other chemical species inside the 21-PWR (pressurized-water reactor) waste package (WP). The scope of this calculation is limited to the time period between 5,000 and 100,000 years after emplacement. The information provided by the sketches attached to this calculation is that of the potential design for the type of WP considered in this calculation. The results of this calculation will be used to evaluate nitric acid corrosion of fuel cladding from radiolysis in the 21-PWR WP. This calculation was performed in accordance with the Technical Work Plan for: Waste Package Design Description for LA (Civilian Radioactive Waste Management System (CRWMS) Management and Operating Contractor (M&O) 2000a). AP-3.124, Calculations, is used to perform the calculation and develop the document. This calculation is associated with the total system performance assessment (TSPA) of which the spent fuel cladding integrity is to be evaluated.

  13. Gamma and Neutron Radiolysis in the 21-PWR Waste Package

    International Nuclear Information System (INIS)

    J.S. Tang

    2001-01-01

    The objective of this calculation is to compute gamma and neutron dose rates in order to determine the maximum radiolytic production of nitric acid and other chemical species inside the 21-PWR (pressurized-water reactor) waste package (WP). The scope of this calculation is limited to the time period between 5,000 and 100,000 years after emplacement. The information provided by the sketches attached to this calculation is that of the potential design for the type of WP considered in this calculation. The results of this calculation will be used to evaluate nitric acid corrosion of fuel cladding from radiolysis in the 21-PWR WP. This calculation was performed in accordance with the Technical Work Plan for: Waste Package Design Description for LA (Civilian Radioactive Waste Management System (CRWMS) Management and Operating Contractor (M and O) 2000a). AP-3.124, Calculations, is used to perform the calculation and develop the document. This calculation is associated with the total system performance assessment (TSPA) of which the spent fuel cladding integrity is to be evaluated

  14. Four-fluid model of PWR degraded cores

    International Nuclear Information System (INIS)

    Dearing, J.F.

    1985-01-01

    This paper describes the new two-dimensional, four-fluid fluid dynamics and heat transfer (FLUIDS) module of the MELPROG code. MELPROG is designed to give an integrated, mechanistic treatment of pressurized water reactor (PWR) core meltdown accidents from accident initiation to vessel melt-through. The code has a modular data storage and transfer structure, with each module providing the others with boundary conditions at each computational time step. Thus the FLUIDS module receives mass and energy source terms from the fuel pin module, the structures module, and the debris bed module, and radiation energy source terms from the radiation module. MELPROG, which models the reactor vessel, is also designed to model the vessel as a component in the TRAC/PF1 networking solution of a PWR reactor coolant system (RCS). The coupling between TRAC and MELPROG is implicit in the fluid dynamics of the reactor coolant (liquid water and steam) allowing an accurate simulation of the coupling between the vessel and the rest of the RCS during an accident. This paper deals specifically with the numerical model of fluid dynamics and heat transfer within the reactor vessel, which allows a much more realistic simulation (with less restrictive assumptions on physical behavior) of the accident than has been possible before

  15. Beta and gamma dose calculations for PWR and BWR containments

    International Nuclear Information System (INIS)

    King, D.B.

    1989-07-01

    Analyses of gamma and beta dose in selected regions in PWR and BWR containment buildings have been performed for a range of fission product releases from selected severe accidents. The objective of this study was to determine the radiation dose that safety-related equipment could experience during the selected severe accident sequences. The resulting dose calculations demonstrate the extent to which design basis accident qualified equipment could also be qualified for the severe accident environments. Surry was chosen as the representative PWR plant while Peach Bottom was selected to represent BWRs. Battelle Columbus Laboratory performed the source term release analyses. The AB epsilon scenario (an intermediate to large LOCA with failure to recover onsite or offsite electrical power) was selected as the base case Surry accident, and the AE scenario (a large break LOCA with one initiating event and a combination of failures in two emergency cooling systems) was selected as the base case Peach Bottom accident. Radionuclide release was bounded for both scenarios by including spray operation and arrested sequences as variations of the base scenarios. Sandia National Laboratories used the source terms to calculate dose to selected containment regions. Scenarios with sprays operational resulted in a total dose comparable to that (2.20 x 10 8 rads) used in current equipment qualification testing. The base case scenarios resulted in some calculated doses roughly an order of magnitude above the current 2.20 x 10 8 rad equipment qualification test region. 8 refs., 23 figs., 12 tabs

  16. Design and Development of Virtual Reactivity System for PWR

    International Nuclear Information System (INIS)

    Anwar, M. I.

    2012-01-01

    The reactivity monitoring and investigation is an important mean to ensure the safety operation of a nuclear power plant. But the reactivity of the nuclear reactor usually cannot be directly measured. It should be computed with certain estimation method. In this thesis, an effort has been made using an artificial neural network and highly fluctuating experimental data for predicting the total reactivity of the nuclear reactor based on all components of net reactivity. This virtual reactivity system is designed by taking advantage of neural network's nonlinear mapping capability. Based on analysis of the reactivity contributing factors, several neural network models are built separately for control rod, boron, poisons, fuel Doppler Effect and moderator effect. Extensive simulation and validation tests for PWR show that satisfied results have been obtained with the proposed approach. It presents a new idea to estimate the PWR's reactivity using artificial intelligence. All the design and simulation work is carried out in MATLAB and a real time programming environment is chosen for the computation and prediction of reactivity. (author)

  17. Transient analysis of blowdown thrust force under PWR LOCA

    International Nuclear Information System (INIS)

    Yano, Toshikazu; Miyazaki, Noriyuki; Isozaki, Toshikuni

    1982-10-01

    The analytical results of blowdown characteristics and thrust forces were compared with the experiments, which were performed as pipe whip and jet discharge tests under the PWR LOCA conditions. The blowdown thrust forces obtained by Navier-Stokes momentum equation about a single-phase, homogeneous and separated two-phase flow, assuming critical pressure at the exit if a critical flow condition was satisfied. The following results are obtained. (1) The node-junction method is useful for both the analyses of the blowdown thrust force and of the water hammer phenomena. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of the analysis and experiment is equal to 1.08. (3) The thrust parameter of saturated blowdown has the same one with the value under pressurized condition when the stagnant pressure is chosen as the saturated one. (4) The dominant terms of the blowdown thrust force in the momentum equation are the pressure and momentum terms except that the acceleration term has large contribution only just after the break. (5) The blowdown thrust force in the analysis greatly depends on the selection of the exit pressure. (author)

  18. Liquid radioactive waste processing improvement of PWR nuclear power plants

    International Nuclear Information System (INIS)

    Nery, Renata Wolter dos Reis; Martinez, Aquilino Senra; Monteiro, Jose Luiz Fontes

    2005-01-01

    The study evaluate an inorganic ion exchange to process the low level liquid radwaste of PWR nuclear plants, so that the level of the radioactivity in the effluents and the solid waste produced during the treatment of these liquid radwaste can be reduced. The work compares two types of ion exchange materials, a strong acid cation exchange resin, that is the material typically used to remove radionuclides from PWR nuclear plants wastes, and a mordenite zeolite. These exchange material were used to remove cesium from a synthetic effluent containing only this ion and another effluent containing cesium and cobalt. The breakthrough curves of the zeolite and resin using a fix bed reactor were compared. The results demonstrated that the zeolite is more efficient than the resin in removing cesium from a solution containing cesium and cobalt. The results also showed that a bed combining zeolite and resin can process more volume of an effluent containing cesium and cobalt than a bed resin alone. (author)

  19. Initial Release of Nucliders from Spent PWR Fuels

    International Nuclear Information System (INIS)

    Kim, S. S.; Chun, K. S.; Kim, Y. B.; Choi, J. W.

    1994-01-01

    The relationship between the leaching and gap inventory of spent fuel has been studied. When a specimen of J44H08 spent PWR fuel with 38 GWD/MTU has been leached in the synthetic granitic groundwater in Ar atmosphere, the released fraction of cesium was increased rapidly up to 0,7% at around 500 days and stayed below 0.8% until 3 years. This 0.7% of cesium might be released from the gap in this fuel. The measurement of gap inventory with C15I08 spent PWR fuel, having 35 GWD/MTU and 0.22% of fission gas release, was also determined near 0.6% for the cesium, which is a similar fraction of cesium released from the leaching experiment with J44H08 fuel. Its gap inventories of strontium and iodine were about 0.03 and less than 0.2% respectively. Respective fractions of cesium and strontium in grain boundary of C15I08 were 0.78, 0.009%

  20. 21-PWR Waste Package Side and End Impacts

    International Nuclear Information System (INIS)

    T. Schmitt

    2005-01-01

    The objective of this calculation is to determine the structural response of a 21-Pressurized Water Reactor (PWR) spent nuclear fuel waste package impacting an unyielding surface. A range of initial velocities and initial angles between the waste package and the unyielding surface is studied. The scope of this calculation is limited to estimating the area of the outer shell (OS) where the residual stress exceeds a given limit (hereafter ''damaged area''). The stress limit is defined as a fraction of the yield strength of the OS material, Alloy 22 (SB-575 N06022), at the appropriate temperature. The design of the 21-PWR waste package used in this calculation is that defined in Reference 8. However, a value of 4 mm was used for the gap between the inner shell and the OS, and the thickness of the OS was reduced by 2 mm. The sketch in Attachment I provides additional information not included in Reference 8. All obtained results are valid for this design only. This calculation is associated with the waste package design and was performed by the Specialty Analyses and Waste Package Design Section. The waste package (i.e. uncanistered spent nuclear fuel disposal container) is classified as Quality Level 1

  1. PWR reactor vessel in-service-inspection according to RSEM

    International Nuclear Information System (INIS)

    Algarotti, Marc; Dubois, Philippe; Hernandez, Luc; Landez, Jean Paul

    2006-01-01

    Nuclear services experience Framatome ANP (an AREVA and Siemens company) has designed and constructed 86 Pressurized Water Reactors (PWR) around the world including the three units lately commissioned at Ling Ao in the People's Republic of China and ANGRA 2 in Brazil; the company provided general and specialized outage services supporting numerous outages. Along with the American and German subsidiaries, Framatome ANP Inc. and Framatome ANP GmbH, Framatome ANP is among the world leading nuclear services providers, having experience of over 500 PWR outages on 4 continents, with current involvement in more than 50 PWR outages per year. Framatome ANP's experience in the examinations of reactor components began in the 1970's. Since then, each unit (American, French and German companies) developed automated NDT inspection systems and carried out pre-service and ISI (In-Service Inspections) using a large range of NDT techniques to comply with each utility expectations. These techniques have been validated by the utilities and the safety authorities of the countries where they were implemented. Notably Framatome ANP is fully qualified to provide full scope ISI services to satisfy ASME Section XI requirements, through automated NDE tasks including nozzle inspections, reactor vessel head inspections, steam generator inspections, pressurizer inspections and RPV (Reactor Pressure Vessel) inspections. Intercontrole (Framatome ANP subsidiary dedicated in supporting ISI) is one of the leading NDT companies in the world. Its main activity is devoted to the inspection of the reactor primary circuit in French and foreign PWR Nuclear Power Plants: the reactor vessel, the steam generators, the pressurizer, the reactor internals and reactor coolant system piping. NDT methods mastered by Intercontrole range from ultrasonic testing to eddy current and gamma ray examinations, as well as dye penetrant testing, acoustic monitoring and leak testing. To comply with the high requirements of

  2. Reference upper shelf fracture toughness properties of PWR pressure vessel materials: neutral/basic flux PWR submerged-arc welds

    International Nuclear Information System (INIS)

    Lidbury, D.P.G.

    1987-10-01

    A generic data base, relating to the upper shelf fracture toughness properties (O ≤ T ≤ 300 0 C) of pressurised water reactor (PWR) pressure vessel submerged-arc welds, deposited using neutral or basic fluxes, has been compiled and is presented in summary form within the main body of this report. A comparison with the A533B-1 plate and A508-3 forging data presented in the Second (1982) Report of the Light Water Reactor Study Group suggests the upper shelf fracture toughness properties of RPV submerged-arc welds metals are such that, over the temperature range appropriate to PWR plant operation: (i) initiation toughnesses are generally less than those associated with A533B-1/A508-3 base metals containing < 0.010 wt% S; (ii) enhanced toughnesses, corresponding to 2.0 mm stable crack extension, are comparable with those expected of A533B-1 plate materials containing < 0.010 wt% S. The information gathering exercise has also confirmed that upper shelf toughnesses associated with the use of basic or neutral fluxes are higher than those associated with the use of acidic fluxes. (author)

  3. Evaluation of the heat transfer in a geological repository concept containing PWR, VHTR and hybrid ads-fission spent fuels

    Energy Technology Data Exchange (ETDEWEB)

    Jonusan, Raoni A.S.; Pereira, Fernando; Velasquez, Carlos E.; Salome, Jean A.D.; Cardoso, Fabiano; Pereira, Claubia; Fortini, Angela, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    The investigation of the thermal behavior of spent fuel (SF) materials is essential to determining appropriate potential sites to accommodate geological repositories as well as the design of canisters, considering their potential risk to people health and of environmental contamination. This work presents studies of the temperature in a canister containing spent fuels discharged from Pressurized Water Reactor (PWR), Very High-Temperature Reactor (VHTR) and Accelerator-Driven Subcritical Reactor System (ADS) reactor systems in a geological repository concept. The thermal analyses were performed with the software ANSYS, which is widely used to solve engineering problems through the Finite Element Method. The ANSYS Transient Thermal module was used. The spent nuclear fuels were set as heat sources using data of previous studies derived from decay heat curves. The studies were based on comparison of the mean temperature on a canister surface along the time under geological disposal conditions, for a same amount of each type of spent nuclear fuel evaluated. The results conclude that fuels from VHTR and ADS systems are inappropriate to be disposed in a standardized PWR canister, demanding new studies to determine the optimal amount of spent fuel and new internal canister geometries. It is also possible to conclude that the hypothetical situation of a single type of canister being used to accommodate different types of spent nuclear fuels is not technically feasible. (author)

  4. Design and retrofit of radiation monitoring system for the PWR nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Tao; Xiong Guohua; Lang Yukai; Guo Wei

    2011-01-01

    Radiation monitoring system is important for the PWR nuclear power plant, and the research of design methods and principles for the radiation monitoring system can greatly improve the design ability of the system for PWR nuclear power plant, and reduce the risk of system retrofit. According to the Nuclear power plant regulations and design specifications, and taking the design and retrofit experience of the radiation monitoring system in Daya Bay Nuclear Power Plant into account, the general design principles and requirements of the radiation monitoring system in the PWR nuclear power plant is proposed, and the retrofit method of the radiation monitoring system in Daya Bay Nuclear Power Plant is briefly introduced. (authors)

  5. Status and future perspectives of PWR and comparing views on WWER fuel technology

    International Nuclear Information System (INIS)

    Weidinger, H.

    2003-01-01

    The main purpose of this paper is to give an overview on status and future perspectives of the Western PWR fuel technology. For easer understanding and correlating, some comparing views to the WWER fuel technology are provided. This overview of the PWR fuel technology of course can not go into the details of the today used designs of fuel, fuel rods and fuel assemblies. However, it tries to describe the today achieved capability of PWR fuel technology with regard to reliability, efficiency and safety

  6. Preliminary study of the economics of enriching PWR fuel with a fusion hybrid reactor

    International Nuclear Information System (INIS)

    Kelly, J.L.

    1978-09-01

    This study is a comparison of the economics of enriching uranium oxide for pressurized water reactor (PWR) power plant fuel using a fusion hybrid reactor versus the present isotopic enrichment process. The conclusion is that privately owned hybrid fusion reactors, which simultaneously produce electrical power and enrich fuel, are competitive with the gaseous diffusion enrichment process if spent PWR fuel rods are reenriched without refabrication. Analysis of irradiation damage effects should be performed to determine if the fuel rod cladding can withstand the additional irradiation in the hybrid and second PWR power cycle. The cost competitiveness shown by this initial study clearly justifies further investigations

  7. ANALISIS SENSITIVITAS TURBULENSI ALIRAN PADA KANAL BAHAN BAKAR PWR BERBASIS CFD

    Directory of Open Access Journals (Sweden)

    Endiah Puji Hastuti

    2015-04-01

    Full Text Available Turbulensi aliran pendingin pada proses perpindahan panas berfungsi untuk meningkatkan nilai koefisien perpindahan panas, tidak terkecuali aliran dalam kanal bahan bakar. Program CFD (CFD=computational fluid dynamics, FLUENT adalah program komputasi berbasis elemen hingga (finite element yang mampu memprediksi dan menganalisis fenomena dinamika aliran fluida secara teliti. Program perhitungan CFD dipilih dalam penelitian ini karena selain akurat juga dapat memberikan visualisasi dengan baik. Penelitian ini bertujuan untuk memahami karakteristika perpindahan panas, massa dan momentum dari dinding rod bahan bakar ke pendingin secara visual, pada medan temperatur, medan tekanan, dan medan energi kinetika pendingin, sebagai fungsi dinamika aliran di dalam kanal, pada kondisi tunak dan transien. Analisis dinamika aliran pada kanal bahan bakar PWR berbasis CFD dilakukan dengan menggunakan sampel data reaktor PWR dengan daya 1000 MWe dengan susunan bahan bakar 17x17. Untuk menguji sensitivitas persamaan aliran yang sesuai dengan model aliran turbulen pada kanal bahan bakar dilakukan pemodelan dengan menggunakan persamaan k-omega (Ƙ-ω, k-epsilon (Ƙ-ε, dan Reynold stress model (RSM. Pada analisis sensitivitas aliran turbulen di dalam kanal digunakan model mesh hexahedral dengan memilih tiga geometri sel yang masing masing berukuran 0,5 mm; 0,2 mm dan 0,15 mm. Hasil analisis menunjukkan bahwa pada analisis kondisi tunak (steady state, terdapat hasil yang mirip pada model turbulen Ƙ-ε standard dan Ƙ-ω standard. Pengujian terhadap kriteria Dittus Boelter untuk bilangan Nusselt menunjukkan bahwa model Reynold stress model (RSM direkomendasikan. Analisis sensitivitas terhadap geometri mesh antara sel yang berukuran 0,5 mm, 0,2 mm dan 0,15 mm, menunjukkan bahwa geometri sel sebesar 0,5 mm telah mencukupi. Aliran turbulen berkembang penuh telah tercapai pada model LES dan DES, meskipun hanya dalam waktu singkat (3 s, model LES memerlukan waktu komputasi

  8. TRANSPORT CHARACTERISTICS OF SELECTED PWR LOCA GENERATED DEBRIS

    International Nuclear Information System (INIS)

    MAJI, A. K.; MARSHALL, B.

    2000-01-01

    In the unlikely event of a Loss of Coolant Accident (LOCA) in a pressurized water reactor (PWR), break jet impingement would dislodge thermal insulation FR-om nearby piping, as well as other materials within the containment, such as paint chips, concrete dust, and fire barrier materials. Steam/water flows induced by the break and by the containment sprays would transport debris to the containment floor. Subsequently, debris would likely transport to and accumulate on the suction sump screens of the emergency core cooling system (ECCS) pumps, thereby potentially degrading ECCS performance and possibly even failing the ECCS. In 1998, the U. S. Nuclear Regulatory Commission (NRC) initiated a generic study (Generic Safety Issue-191) to evaluate the potential for the accumulation of LOCA related debris on the PWR sump screen and the consequent loss of ECCS pump net positive suction head (NPSH). Los Alamos National Laboratory (LANL), supporting the resolution of GSI-191, was tasked with developing a method for estimating debris transport in PWR containments to estimate the quantity of debris that would accumulate on the sump screen for use in plant specific evaluations. The analytical method proposed by LANL, to predict debris transport within the water that would accumulate on the containment floor, is to use computational fluid dynamics (CFD) combined with experimental debris transport data to predict debris transport and accumulation on the screen. CFD simulations of actual plant containment designs would provide flow data for a postulated accident in that plant, e.g., three-dimensional patterns of flow velocities and flow turbulence. Small-scale experiments would determine parameters defining the debris transport characteristics for each type of debris. The containment floor transport methodology will merge debris transport characteristics with CFD results to provide a reasonable and conservative estimate of debris transport within the containment floor pool and

  9. Sizewell 'B' PWR pre-construction safety report

    International Nuclear Information System (INIS)

    1982-04-01

    The Pre-Construction Safety Report (PCSR) for a PWR power station to be constructed as Sizewell 'B' is presented in 13 volumes containing 16 chapters. The PCSR has been submitted to the Nuclear Installations Inspectorate in support of the Central Electricity Generating Board's application for consent to the extension at Sizewell. It describes the design and provides the safety case for the proposed station, which comprises a 4-loop pressurized water reactor with associated generating plant and supporting auxiliary equipment. A general description of the station and its site is given. The strategy for ensuring nuclear safety is set out and the general design aspects of systems and plant outlined. The plant and systems, including their safety design bases and the fault analyses carried out for the design are described. Finally the way in which the plant will be decommissioned at the end of its useful life is outlined. (U.K.)

  10. Numerical regulation of a test facility of materials for PWR

    International Nuclear Information System (INIS)

    Zauq, M.H.

    1982-02-01

    The installation aims at testing materials used in nuclear power plants; tests consists in simulations of a design basis accident (failure of a primary circuit of a PWR type reactor) for a qualification of these materials. A description of the test installation, of the thermodynamic control, and of the control system is presented. The organisation of the software is then given: description of the sequence chaining monitor, operation, list and function of the programs. The analog information processing is also presented (data transmission). A real-time microcomputer and clock are used for this work. The microprocessor is the 6800 of MOTOROLA. The microcomputer used has been built around the MC 6800; its structure is described. The data acquisition include an analog data acquisition system and a numerical data acquisition system. Laboratory and on-site tests are finally presented [fr

  11. Reactor building seismic analysis of a PWR type - NPP

    International Nuclear Information System (INIS)

    Kakubo, Masao

    1983-01-01

    Earthquake engineering studies raised up in Brazil during design licensing and construction phases of Almirante Alvaro Alberto NPP, units 1 and 2. State of art of soil - structure interaction analysis with particular reference to the impedance function calculation analysis with particular reference to the impedance function calculation of a group of pile is presented in this M.Sc. Dissertation, as an example the reactor building dynamic response of a 1325 MWe NPP PWR type is calculated. The reactor building is supported by a pile foundation with 2002 end bearing piles. Upper and lower bound soil parameters are considered in order to observe their influence on dynamic response of structure. Dynamic response distribution on pile heads show pile-soil-pile interaction effects. (author)

  12. Neutron measurements in borated water for PWR fuel inspections

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1984-07-01

    A fork detector has been developed for use in the international effort to safeguard irradiated fuel assemblies. To improve interpretation of data from a fork, the following three facets of the detector's neutron counting response have been examined using a tank of borated water and a PWR fresh-fuel assembly: (1) The detector's sensitivity to neutrons initiated at different positions within the assembly was measured and this sensitivity can be used to generate total responses to assemblies with uniform or nonuniform irradiation. (2) Using fission chambers with and without cadmium wrappings provided ratios of count rates that can give an independent estimate of the boron concentration in the water. The precision of a boron determination can be estimated from these measurements. (3) The water temperature was raised, causing small but possibly important effects on the count rates. These facets of the fork detector's neutron response were studied at boron concentrations ranging from 0 to about 3500 ppM

  13. B ampersand W PWR advanced control system algorithm development

    International Nuclear Information System (INIS)

    Winks, R.W.; Wilson, T.L.; Amick, M.

    1992-01-01

    This paper discusses algorithm development of an Advanced Control System for the B ampersand W Pressurized Water Reactor (PWR) nuclear power plant. The paper summarizes the history of the project, describes the operation of the algorithm, and presents transient results from a simulation of the plant and control system. The history discusses the steps in the development process and the roles played by the utility owners, B ampersand W Nuclear Service Company (BWNS), Oak Ridge National Laboratory (ORNL), and the Foxboro Company. The algorithm description is a brief overview of the features of the control system. The transient results show that operation of the algorithm in a normal power maneuvering mode and in a moderately large upset following a feedwater pump trip

  14. PWR-blowdown heat transfer separate effects program

    International Nuclear Information System (INIS)

    Thomas, D.G.

    1976-01-01

    The ORNL Pressurized-Water Reactor Blowdown Heat Transfer (PWR-BDHT) Program is an experimental separate-effects study of the relations among the principal variables that can alter the rate of blowdown, the presence of flow reversal and rereversal, time delay to critical heat flux, the rate at which dryout progresses, and similar time-related functions that are important to LOCA analysis. Primary test results are obtained from the Thermal-Hydraulic Test Facility (THTF). Supporting experiments are carried out in several additional test loops - the Forced Convection Test Facility (FCTF), an air-water loop, a transient steam-water loop, and a low-temperature water mockup of the THTF heater rod bundle. The studies to date are described

  15. Specification of water quality for the FRAMATOME PWR secondary circuit

    International Nuclear Information System (INIS)

    Nordmann, F.

    1980-03-01

    This paper describes the purpose, theory and scope of secondary system chemical specifications for FRAMATOME PWR nuclear power plants. All volatile treatment was chosen: controlling the feedwater pH by means of a volatile amine (ammonia, morpholine), and excluding oxygen by the addition of hydrazine. The pollutants are monitored at the steam generator drains by completely automatic measurements using simple and reliable techniques: pH measurement and a diagram of the cation conductivity versus sodium. An explanation is given of the monitoring techniques and to the effect of the various kinds of possible pollutant. A new concept is described, the annual quota expressed in day.microsiements.cm -1 which enables the amount of absorbed pollutants in the steam generator to be evaluated. The methods used for maintaining the desired chemical quality are dealt with [fr

  16. Reliability assessment of the containment of a PWR

    International Nuclear Information System (INIS)

    Schueller, G.I.; Wellein, R.; Wittmann, F.H.; Boulahdour, T.; Mihashi, M.; Zorn, N.F.; Bauer, J.

    1981-09-01

    The aim of this research effort was to contribute to the development of methods to quantify the risk involved with nuclear power plants. Using a large component, i.e. the containment of the reference plant BIBLIS B (PWR) as sample structure a reliability analysis was performed which is based on realistic assumptions of loads and material properties. For this purpose in many fields it was necessary to develop new methods, collect data, and where not available, obtain data in tests. This effort concentrated on partial aspects and on the other hand on the development of a methodology for an overall reliability concept. According to the results of the previous project, the keypoints of this effort are the treatment of loss of coolant accidents (small leak), earthquake loading, the possibly resulting crackpropagation in the steel hull, and the structural mechanics and material strength aspects of the reinforced concrete hull subjected to impact loading (aircraft impact). (orig./HP) [de

  17. Neutronal aspects of PWR control for transient load following

    International Nuclear Information System (INIS)

    Cossic, A.

    1985-01-01

    The purpose of this thesis is to qualify the CRONOS diffusion code on a load transient in grey mode control. First of all, we have established a general axial calculational model and studied the important physical phenomena: xenon oscillation, grey rods absorption, radial leaks modelling, effect of the initial conditions in Iodine and Xenon. In a second stage, a three dimensional calculation has been performed, the results of which have been compared to a PWR 900 TRICASTIN 3 experiment and have been in good agreement. In the last part, we show that the results of the axial model using one-dimensional CRONOS calculations are quite consistent with the three-dimensional calculation [fr

  18. Delayed phenomena analysis from French PWR containment instrumentation system

    International Nuclear Information System (INIS)

    Costaz, J.L.

    1987-01-01

    The analysis of the large amount of measurements which has been now gathered by EDF on its twenty two PWR 900 MW shows that the behaviour of concrete under creep and shrinkage effects is in good agreement with the values given as correct estimates by french regulations and taken into account for the design of nuclear prestressed structures. None of the containment buildings studied here showed significant differences with the regulations theoretical values and consequently all the measurements remain in the field of the allowable strain variations used for design. On the other hand, if the instant loading elastic modulus is clearly determined for each containment, and its effect on theoretical creep taken into account, it was not possible up till now to extract from measurements some particular effects such as type of concrete and agregates or climatic effects. (orig.)

  19. PWR steam generator chemical cleaning, Phase I. Final report

    International Nuclear Information System (INIS)

    Rothstein, S.

    1978-07-01

    United Nuclear Industries (UNI) entered into a subcontract with Consolidated Edison Company of New York (Con Ed) on August 8, 1977, for the purpose of developing methods to chemically clean the secondary side tube to tube support crevices of the steam generators of Indian Point Nos. 1 and 2 PWR plants. This document represents the first reporting on activities performed for Phase I of this effort. Specifically, this report contains the results of a literature search performed by UNI for the purpose of determining state-of-the-art chemical solvents and methods for decontaminating nuclear reactor steam generators. The results of the search sought to accomplish two objectives: (1) identify solvents beyond those proposed at present by UNI and Con Ed for the test program, and (2) confirm the appropriateness of solvents and methods of decontamination currently in use by UNI

  20. Non linear identification applied to PWR steam generators

    International Nuclear Information System (INIS)

    Poncet, B.

    1982-11-01

    For the precise industrial purpose of PWR nuclear power plant steam generator water level control, a natural method is developed where classical techniques seem not to be efficient enough. From this essentially non-linear practical problem, an input-output identification of dynamic systems is proposed. Through Homodynamic Systems, characterized by a regularity property which can be found in most industrial processes with balance set, state form realizations are built, which resolve the exact joining of local dynamic behaviors, in both discrete and continuous time cases, avoiding any load parameter. Specifically non-linear modelling analytical means, which have no influence on local joined behaviors, are also pointed out. Non-linear autoregressive realizations allow us to perform indirect adaptive control under constraint of an admissible given dynamic family [fr

  1. Optimization of the decontamination in EDF PWR power plants

    International Nuclear Information System (INIS)

    Gosset, P.; Dupin, M.; Buisine, D.; Buet, J.F.; Brunel, V.

    2002-01-01

    The optimisation of decontamination in EDF PWR power plants is the result of a permanent collaborative work between the plant operators, the subcontractors, central services of nuclear power division of EDF. This collaborative work enables the saving of all the feedback experience. The main operations carried out on nuclear sites like mechanical decontamination of valves, use of the ''EMMAC'' process on big components (replacement of steam generator, hydraulic parts of the reactor coolant pumps), use of foam on pools walls and divers in highly contaminated pools have been discussed. This paper shows that the choice of decontamination processes is very dependant on the components, on the dose rate reduction to be aimed and on the possibility to treat the waste on site. (authors)

  2. Fracture mechanics evaluation for at typical PWR primary coolant pipe

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T. [Kansai Electric Power Company, Osaka (Japan); Shimizu, S.; Ogata, Y. [Mitsubishi Heavy Industries, Ltd., Kobe (Japan)

    1997-04-01

    For the primary coolant piping of PWRs in Japan, cast duplex stainless steel which is excellent in terms of strength, corrosion resistance, and weldability has conventionally been used. The cast duplex stainless steel contains the ferrite phase in the austenite matrix and thermal aging after long term service is known to change its material characteristics. It is considered appropriate to apply the methodology of elastic plastic fracture mechanics for an evaluation of the integrity of the primary coolant piping after thermal aging. Therefore we evaluated the integrity of the primary coolant piping for an initial PWR plant in Japan by means of elastic plastic fracture mechanics. The evaluation results show that the crack will not grow into an unstable fracture and the integrity of the piping will be secured, even when such through wall crack length is assumed to equal the fatigue crack growth length for a service period of up to 60 years.

  3. Low concentration NP preoxidation condition for PWR decontamination

    International Nuclear Information System (INIS)

    Huang Fuduan; Yu Degui; Lu Jingju; Ding Dejun; Zhao Yukun

    1991-02-01

    To use preoxidation condition with low concentration NP (nitric acid permanganate) instead of conventional high concentration AP (alkline permanganate ) for PWR oxidation decontamination (POD) was summarized. Experiments including three parts have been performed. The defilming performance and decontamination factor of preoxidation with low concentration NP, which is 100, 10 times lower than that of AP are better than that with high concentration AP. The reason has been studied with the aid of prefilmed specimens of corrosion potential measuring in NP solution and chromium release in NP and AP solutions. The behaviour of alloy 13 prefilmed specimen in NP preoxidation solution is different from 18-8 ss and Incoloy 800. In the low acidity, the corrosion potential moves toward positive direction as the acidity becomes high

  4. Analysis of reactivity insertion accidents in PWR reactors

    International Nuclear Information System (INIS)

    Camargo, C.T.M.

    1978-06-01

    A calculation model to analyze reactivity insertion accidents in a PWR reactor was developed. To analyze the nuclear power transient, the AIREK-III code was used, which simulates the conventional point-kinetic equations with six groups of delayed neutron precursors. Some modifications were made to generalize and to adapt the program to solve the proposed problems. A transient thermal analysis model was developed which simulates the heat transfer process in a cross section of a UO 2 fuel rod with Zircalloy clad, a gap fullfilled with Helium gas and the correspondent coolant channel, using as input the nulcear power transient calculated by AIREK-III. The behavior of ANGRA-i reactor was analized during two types of accidents: - uncontrolled rod withdrawal from subcritical condition; - uncontrolled rod withdrawal at power. The results and conclusions obtained will be used in the license process of the Unit 1 of the Central Nuclear Almirante Alvaro Alberto. (Author) [pt

  5. Contribution to the experimental qualification of PWR fuel storage calculations

    International Nuclear Information System (INIS)

    Marsault, Philippe.

    1980-12-01

    Experiments were carried out on assemblies representative of those used in PWR reactors in a configuration made critical with a driver zone. In this way, certain parameters were able to be measured using current classical techniques. As the multiplication factor for a group of assemblies cannot be determined directly, substitutions were made with an equivalent homogeneous lattice in which Laplacian measurements could be made. The k(infinite) factor was obtained by introducing a migration area which can only be obtained from calculations. Experimental storage studies realized during the CRISTO 1 campaign utilize: 1) a lattice with 4 14x14 pin assemblies immersed in ordinary water; 2) a lattice with 4 14x14 pin assemblies and 3) a regular lattice. The CRISTO experiment enabled criticality calculations to be qualified with these lattices for storage under accidental conditions [fr

  6. PWR steam generator chemical cleaning, Phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rothstein, S.

    1978-07-01

    United Nuclear Industries (UNI) entered into a subcontract with Consolidated Edison Company of New York (Con Ed) on August 8, 1977, for the purpose of developing methods to chemically clean the secondary side tube to tube support crevices of the steam generators of Indian Point Nos. 1 and 2 PWR plants. This document represents the first reporting on activities performed for Phase I of this effort. Specifically, this report contains the results of a literature search performed by UNI for the purpose of determining state-of-the-art chemical solvents and methods for decontaminating nuclear reactor steam generators. The results of the search sought to accomplish two objectives: (1) identify solvents beyond those proposed at present by UNI and Con Ed for the test program, and (2) confirm the appropriateness of solvents and methods of decontamination currently in use by UNI.

  7. In situ corrosion monitoring of steam generators. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Kendig, M W; Isaacs, H S

    1978-06-01

    An ac electrochemical technique which meets the basic requirements for an in situ localized corrosion monitor within the secondary coolant of PWR steam generators has been investigated. The technique uses two electrodes to measure the electrochemical impedance of a surface in an occluded region with high heat flux. The impedance is related to the kinetics of corrosion. Marked decreases indicate the onset of a high corrosion rate. Experiments have demonstrated the ability of the technique to determine the onset of corrosion under conditions of high solution resistance and solution agitation due to local boiling. Experiments have shown the technique operates similarly in pressurized 300/sup 0/C water, 1,400 ppM in Na/sub 2/SO/sub 4/.

  8. Radiation risk analysis of tritium in PWR plants

    International Nuclear Information System (INIS)

    Yang Maochun; Wang Shimin

    1999-03-01

    Tritium is a common radionuclide in PWR nuclear power plant. In the normal operation conditions, its radiation risk to plant workers is the internal radiation exposure when tritium existing in air as HTO (hydrogen tritium oxide) is breathed in. As the HTO has the same physical and chemical characteristics as water, the main way that HTO entering the air is by evaporation. There are few opening systems in Nuclear Power Plant, the radiation risk of tritium mainly exists near the area of spent fuel pit and reactor pit. The highest possible radiation risk it may cause--the maximum concentration in air is the level when equilibrium is established between water and air phases for tritium. The author analyzed the relationship among the concentration of HTO in water, in air and the water temperature when equilibrium is established, the equilibrated HTO concentration in air increases with HTO concentration in water and water temperature. The analysis revealed that at 30 degree C, the equilibrated HTO concentration in air might reach 1 DAC (derived air concentration) when the HTO concentration in water is 28 GBq/m 3 . Owing to the operation of plant ventilation systems and the existence of moisture in the input air of the ventilation, the practical tritium concentration in air is much lower than its equilibrated levels, the radiation risk of tritium in PWR plant is quite limited. In 1997, Daya Bay Nuclear Power Plant's practical monitoring result of the HTO concentration in the air of the nuclear island and the urine of workers supported this conclusion. Based on this analysis, some suggestions to the reduction of tritium radiation risk were made

  9. Probe for detection of denting in PWR steam generator tubes

    International Nuclear Information System (INIS)

    Gerardin, J.P.; Germain, J.L.; Nio, J.C.

    1994-07-01

    In certain types of PWR steam generator, oxide deposits can lead to embedding, and subsequently to deformation of a tube (the phenomenon of ''denting''). Such embedding changes the vibratory behavior of the tubes and can result in fatigue cracking. This type of cracking can also be worsened in the event of improper assembly of the anti-vibration spacer bars supporting the U-bends. To prevent such incidents and provide for effective preventive condition-directed maintenance of its PWR steam generators, EDF has undertaken the study and development of a probe to detect this type of phenomenon. The studies began in 1990 and led to the building of an initial prototype probe. The principle behind the probe consists in inducing vibration in the U-bend and determining the main resonance modes of the tube. Measurements of frequency and amplitude and calculation of damping enable characterization of the mechanical behavior of the U-bend. The most important parameter is damping, for which the value must be sufficiently high to ensure that the tube is not subjected to major vibratory amplitudes during operation. Numerous tests have been performed with the first prototype version of the probe, on a mock-up in the test area and on one of the demounted steam generators on the Dampierre site. These different tests have enabled validation of the operating principle, fine-tuning the process, pinpointing certain mechanical problems in the probe design, and obtaining the first indications as to the real vibratory behavior of U-bends on a steam generator. On the basis of these preliminary tests, the specifications were drawn up for an industrial version of the probe. Following a call for bids and the choice of a manufacturer, work began on fabrication of a new probe model in 1993. This version was delivered at the end of 1993 and testing began in 1994. (authors). 5 figs., 2 tabs

  10. Corrosion Resistance Evaluation of HANA Claddings in Commercial PWR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee-Hun; Kwon, Oh-Hyun; Kim, Hong-Jin; Yoo, Jong-Sung; Kim, Yong-Hwan [KEPCO NF, Daejeon (Korea, Republic of)

    2014-10-15

    Korea Atomic Energy Research Institute (KAERI) in collaboration with KEPCO Nuclear Fuel (KNF) developed newly-advanced alloy which are named HANA (High-performance Alloy for Nuclear Application) for high burnup PWR nuclear fuel, showed an excellent out-pile corrosion resistance in PWR simulating loop conditions. And in-pile corrosion resistance of HANA claddings, which was examined at the first provisional inspection after -185 FPD of irradiation in the Halden Reactor, and also shown superior to the other references alloy. Also, other researches showed a much better corrosion resistance when compared to the other Zr-based alloy in various corrosion conditions. In this study, the LTA program for newly-developed fuel assembly (HIPER) with the HANA claddings was implemented to justify the performance for 3 cycles of operation schedule in Hanul nuclear power plant. The objective of this study is to compare corrosion properties of reference alloy with HANA claddings loaded in Hanul nuclear power plant.. For the examination procedures, the oxide thickness measurements method and equipment of PSE are described in detail as follow in measurement methods chapter. Finally, based on the above mentioned measurements method, the summarized oxide thickness data obtained from PSE are evaluated for the corrosion resistance in commercial nuclear power plant and some discussion for the corrosion resistance are described. In the past, corrosion resistance of HANA claddings was successfully conducted in test reactor. In this study, the corrosion characteristic of HANA claddings which are applied to HIPER is examined in the commercial nuclear power plant. HANA claddings in the HIPER showed a more improved corrosion resistance than reference alloy claddings and are evaluated well with meeting the oxide thickness criteria.

  11. PWR and BWR spent fuel assembly gamma spectra measurements

    Science.gov (United States)

    Vaccaro, S.; Tobin, S. J.; Favalli, A.; Grogan, B.; Jansson, P.; Liljenfeldt, H.; Mozin, V.; Hu, J.; Schwalbach, P.; Sjöland, A.; Trellue, H.; Vo, D.

    2016-10-01

    A project to research the application of nondestructive assay (NDA) to spent fuel assemblies is underway. The research team comprises the European Atomic Energy Community (EURATOM), embodied by the European Commission, DG Energy, Directorate EURATOM Safeguards; the Swedish Nuclear Fuel and Waste Management Company (SKB); two universities; and several United States national laboratories. The Next Generation of Safeguards Initiative-Spent Fuel project team is working to achieve the following technical goals more easily and efficiently than in the past using nondestructive assay measurements of spent fuel assemblies: (1) verify the initial enrichment, burnup, and cooling time of facility declaration; (2) detect the diversion or replacement of pins, (3) estimate the plutonium mass, (4) estimate the decay heat, and (5) determine the reactivity of spent fuel assemblies. This study focuses on spectrally resolved gamma-ray measurements performed on a diverse set of 50 assemblies [25 pressurized water reactor (PWR) assemblies and 25 boiling water reactor (BWR) assemblies]; these same 50 assemblies will be measured with neutron-based NDA instruments and a full-length calorimeter. Given that encapsulation/repository and dry storage safeguards are the primarily intended applications, the analysis focused on the dominant gamma-ray lines of 137Cs, 154Eu, and 134Cs because these isotopes will be the primary gamma-ray emitters during the time frames of interest to these applications. This study addresses the impact on the measured passive gamma-ray signals due to the following factors: burnup, initial enrichment, cooling time, assembly type (eight different PWR and six different BWR fuel designs), presence of gadolinium rods, and anomalies in operating history. To compare the measured results with theory, a limited number of ORIGEN-ARP simulations were performed.

  12. A comparison of fuzzy logic-PID control strategies for PWR pressurizer control

    International Nuclear Information System (INIS)

    Kavaklioglu, K.; Ikonomopoulos, A.

    1993-01-01

    This paper describes the results obtained from a comparison performed between classical proportional-integral-derivative (PID) and fuzzy logic (FL) controlling the pressure in a pressurized water reactor (PWR). The two methodologies have been tested under various transient scenarios, and their performances are evaluated with respect to robustness and on-time response to external stimuli. One of the main concerns in the safe operation of PWR is the pressure control in the primary side of the system. In order to maintain the pressure in a PWR at the desired level, the pressurizer component equipped with sprayers, heaters, and safety relief valves is used. The control strategy in a Westinghouse PWR is implemented with a PID controller that initiates either the electric heaters or the sprayers, depending on the direction of the coolant pressure deviation from the setpoint

  13. Coordinated U. S. PWR Reactor Vessel Surveillance Program: Surveillance Data to Support Long Term Operations

    International Nuclear Information System (INIS)

    Hosler, Ryan; Troyer, Greg; Davidsaver, Sarah; Hardin, Timothy

    2012-01-01

    Irradiated reactor pressure vessel (RPV) surveillance data is used as the basis for embrittlement trend correlations (ETCs) which predict decreases in RP fracture toughness due to irradiation embrittlement. A limited amount of data exists today at fluences that many U. S. PWR RPVs will reach in 60 or more years of operation. However, there is a significant amount of test reactor data available at high fluences, which shows higher embrittlement shifts than the power reactor data-based correlations. A coordinated plan for withdrawal and testing of the U. S. PWR RPV surveillance capsules has been developed, with the intent of filling high fluence gaps in existing PWR data. This paper summarizes the methodology, optimization strategy, and current results of this coordinated U. S. PWR reactor vessel surveillance program (CRVSP). The Coordinated RVSP has been optimized to maximize the quantity and quality of high fluence data while minimizing the burden on the industry

  14. A method to determine the dampening system of control rod drop mechanism for PWR reactors

    International Nuclear Information System (INIS)

    Trindade, C.E.; Mattos, J.R.L. de; Perrotta, J.A.

    1988-08-01

    A method to determine the Control Assembly damping drop system (dashpot/guide tube) was developed. It's presented a theoretical model, an experimental device and the procedures to determine this system, which is used in PWR reactors. (author) [pt

  15. Aspects of PWR nuclear power plant secondary cycle relating to reactor safety

    International Nuclear Information System (INIS)

    Mueller, A.E.F.; Leal, M.R.L.V.; Dominguez, D.

    1981-01-01

    A safety study of the main steam system, condensate and feedwater systems and water treatment system that belong to the secondary cooling circuits of a PWR nuclear power plant is presented. (E.G.) [pt

  16. EDF's PWR power plants: anomalies concerning the reactor core instrumentation system

    International Nuclear Information System (INIS)

    1985-10-01

    This report presents the problems of fatigue and leaks found on the internal core instrumentation thimbles of several French PWR power plants, as also the solutions chosen according the reactor has already or not been operating [fr

  17. Resfria - a computational routine for thermal-hydraulic analysis of a cooldown in the PWR

    International Nuclear Information System (INIS)

    Silva Neto, A.J. da; Maciel Filho, L.A.

    1989-01-01

    This paper presents the computer code RESFRIA, designed to calculate the process parameters in a PWR nuclear power plant during a cooldown normal procedure. The procedure is described and some of the models developed to the simulation of systems and equipments are presented. A simplified flowchart of the computational routine and the results in the form of a diagram, for a typical PWR nuclear power plant, are also presented. (author)

  18. Characterization of Decommissioned PWR Vessel Internals Materials Samples: Material Certification, Fluence, and Temperature (Nonproprietary Version)

    International Nuclear Information System (INIS)

    Krug, M.; Shogan, R.; Fero, A.; Snyder, M.

    2004-01-01

    Pressurized water reactor (PWR) cores, operate under extreme environmental conditions due to coolant chemistry, operating temperature, and neutron exposure. Extending the life of PWRs require detailed knowledge of the changes in mechanical and corrosion properties of the structural austenitic stainless steel components adjacent to the fuel. This report contains basic material characterization information of the as-installed samples of reactor internals material which were harvested from a decommissioned PWR

  19. Teknologi Pembuatan Cermet Du0¬2 - Steel Untuk Wadah Limbah Bahan Bakar Bekas Pwr

    OpenAIRE

    Alimah, Siti; Budiarto, Budiarto

    2005-01-01

    DUO­2-STEEL CERMET MANUFACTURING TECHNOLOGY FOR PWR Spent Nuclear Fuel (SNF) CASKS. Assessment of DU02 - Steel cermet manufacturing technology for PWR SNF casks has been done. DU02 - Steel cermet consisting of DU02 particulates and other particulates, embedded in a steel matrix. Cermet SNF casks have the potential for superior performance compared with casks constructed of other materials. The addition of DU02 ceramic particulates can increase SNF cask capacity, improve of repository performa...

  20. Bias identification in PWR pressurizer instrumentation using the generalized liklihood-ratio technique

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1981-01-01

    A method for detecting and identifying biases in the pressure and level sensors of a pressurized water reactor (PWR) pressurizer is described. The generalized likelihood ratio (GLR) technique performs statistical tests on the innovations sequence of a Kalman filter state estimator and is capable of determining when a bias appears, in what sensor the bias exists, and estimating the bias magnitude. Simulation results using a second-order linear, discrete PWR pressurizer model demonstrate the capabilities of the GLR method

  1. Calibration of four neutron coincidence collars for PWR fresh fuel assemblies

    International Nuclear Information System (INIS)

    De Baere, P.; Carchon, R.; Smaers, G.; Smith, B.G.R.; Cranston, R.; Levy-Gorget, J.L.

    1988-05-01

    A measurement campaign was set up in order to calibrate four Neutron Coincidence Collars. For this purpose, a PWR fuel mock-up was used, as well as a series of real size PWR fuel assemblies. Calibration functions were set up, representing net real coincidence rate as a function of mass loading. All these calibration expressions have been referred to a general calibration expression, by applying some correction factors on the real coincidence count rate. (Author)

  2. Characterization of Decommissioned PWR Vessel Internals Material Samples: Tensile and SSRT Testing (Nonproprietary Version)

    International Nuclear Information System (INIS)

    Krug, M.; Shogan, R.

    2004-01-01

    Pressurized water reactor (PWR) cores operate under extreme environmental conditions due to coolant chemistry, operating temperature, and neutron exposure. Extending the life of PWRs requires detailed knowledge of the changes in mechanical and corrosion properties of the structural austenitic stainless steel components adjacent to the fuel (internals) subjected to such conditions. This project studied the effects of reactor service on the mechanical and corrosion properties of samples of baffle plate, former plate, and core barrel from a decommissioned PWR

  3. Characterization of Decommissioned PWR Vessel Internals Material Samples: Tensile and SSRT Testing (Nonproprietary Version)

    Energy Technology Data Exchange (ETDEWEB)

    M.Krug, R.Shogan

    2004-09-01

    Pressurized water reactor (PWR) cores operate under extreme environmental conditions due to coolant chemistry, operating temperature, and neutron exposure. Extending the life of PWRs requires detailed knowledge of the changes in mechanical and corrosion properties of the structural austenitic stainless steel components adjacent to the fuel (internals) subjected to such conditions. This project studied the effects of reactor service on the mechanical and corrosion properties of samples of baffle plate, former plate, and core barrel from a decommissioned PWR.

  4. Dry Ice Blast Decontamination to in-service equipment in Japanese PWR plant

    International Nuclear Information System (INIS)

    2016-01-01

    MHI had developed several mechanical decontamination methods. Mechanical decontamination is beneficial when it is applied to equipment whose surface is narrow. Especially in terms of secondary waste reduction, MHI started the study of application of Dry Ice Blast Decontamination to actual PWR plant. This paper provides an introduction to Dry Ice Blast Decontamination principle, its system and actual application result to PWR plant. (J.P.N.)

  5. Maintenance service for major component of PWR plant. Replacement of pressurizer safe end weld

    International Nuclear Information System (INIS)

    Miyoshi, Yoshiyuki; Kobayashi, Yuki; Yamamoto, Kazuhide; Ueda, Takeshi; Suda, Naoki; Shintani, Takashi

    2017-01-01

    In October 2016, MHI completed the replacement of safe end weld of pressurizer (Pz) of Ringhals unit 3, which was the first maintenance work for main component of pressurized water reactor (PWR) plant in Europe. For higher reliability and longer lifetime of PWR plant, MHI has conducted many kinds of maintenance works of main components of PWR plants in Japan against stress corrosion cracking due to aging degradation. Technical process for replacement of Pz safe end weld were established by MHI. MHI has experienced the work for 21 PWR units in Japan. That of Ringhals unit 3 was planned and conducted based on the experiences. In this work, Alloy 600 used for welds of nozzles of Pz was replaced with Alloy 690. Alloy 690 is more corrosive-resistant than Alloy 600. Specially designed equipment and technical process were developed and established by MHI to replace safe end weld of Pz and applied for the Ringhals unit 3 as a first application in Europe. The application had been performed in success and achieved the planned replacement work duration and total radiation dose by using sophisticated machining and welding equipment designed to meet the requirements to be small, lightweight and remote-controlled and operating by well skilled MHI personnel experienced in maintenance activities for major components of PWR plant in Japan. The success shows that the experience, activities and technology developed in Japan for main components of PWR plant shall be applicable to contribute reliable operations of nuclear power plants in Europe and other countries. (author)

  6. Metallurgical and mechanical behaviours of PWR fuel cladding tube oxidised at high temperature

    International Nuclear Information System (INIS)

    Stern, A.

    2007-12-01

    Zirconium alloys are used as cladding materials in Pressurized Water Reactors (PWR). As they are submitted to very extreme conditions, it is necessary to check their behaviour and especially to make sure they meet the safety criteria. They are therefore studied under typical in service-loadings but also under accidental loadings. In one of these accidental scenarios, called Loss of Coolant Accident (LOCA) the cladding temperature may increase above 800 C, in a steam environment, and decrease before a final quench of the cladding. During this temperature transient, the cladding is heavily oxidised, and the metallurgical changes lead to a decrease of the post quench mechanical properties. It is then necessary to correlate this drop in residual ductility to the metallurgical evolutions. This is the problem we want to address in this study: the oxidation of PWR cladding materials at high temperature in a steam environment and its consequences on post quench mechanical properties. As oxygen goes massively into the metallic part - a zirconia layer grows at the same time - during the high temperature oxidation, the claddings tubes microstructure shows three different phases that are the outer oxide layer (zirconia) and the inner metallic phases (α(O) and 'ex β') - with various mechanical properties. In order to reproduce the behaviour of this multilayered material, the first part of this study consisted in creating samples with different - but homogeneous in thickness - oxygen contents, similar to those observed in the different phases of the real cladding. The study was especially focused on the β-->α phase transformation upon cooling and on the resulting microstructures. A mechanism was proposed to describe this phase transformation. For instance, we conclude that for our oxygen enriched samples, the phase transformation kinetics upon cooling are ruled by the oxygen partitioning between the two allotropic phases. Then, these materials were mechanically tested at

  7. Modelling of the local chemistry in stagnant areas in the PWR primary circuit

    International Nuclear Information System (INIS)

    Reid, Rick; Fruzzetti, Keith; Ahluwalia, Al; Summe, Alex; Dame, Cecile; Schmitt, Kyle

    2014-01-01

    MRP-236 demonstrated a correlation between stagnant or low flow conditions and stress corrosion cracking (SCC) of stainless steel components in the PWR primary system. Of the approximately 140 SCC events documented (affecting 15 different components), 83% involved stagnant or low flow conditions that were likely to be associated with chemical environments different from the well mixed bulk coolant. The chemistry in such locations is typically not monitored, and sampling is difficult or impossible. Actions to improve chemistry in regions of low or no coolant flow, such as flushing, cycling of components and imposition of more stringent make up water chemistry controls affect both operational costs and outage schedules. Similarly, design changes to improve flow in affected areas are costly or impracticable. Improving the understanding of the factors controlling chemistry in such areas and development of the capability to predict typical and worst case conditions will allow an informed assessment of procedural actions and/or design changes to improve local chemistry and thereby reduce SCC susceptibility. A project was undertaken to develop a model to predict local chemistry conditions in stagnant locations. The model comprises the iterative application of the EPRI MULTEQ solution chemistry equilibrium code and standard thermodynamic relationships to predict local chemistry conditions considered likely to have been present at the surfaces of components when SCC was initiated. The starting chemistry conditions are based on PWR primary system chemistry from different plant maneuvers (e.g., startup and shutdown conditions). The model was applied to three example components where SCC has occurred in the field. The selected components were: control rod drive mechanism canopy seals; valve drain lines; and reactor vessel o-ring leak-off lines. This paper provides a summary of the model and predicted local chemistry conditions that develop for the three example component as a

  8. Probes for inspections of heat exchanges installed at nuclear power plants type PWR by eddy current method; Sondas para inspecao de trocadores de calor instalados em usinas nucleares tipo PWR pelo metodo de correntes parasitas

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alonso F.O. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Enghenharia Mecanica]. E-mail: kauzz21@yahoo.com; Alencar, Donizete A. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)]. E-mail: daa@cdtn.br

    2007-07-01

    From all non destructive examination methods usable to perform integrity evaluation of critical equipment installed at nuclear power plants (NPP), eddy current test (ET) may be considered the most important one, when examining heat exchangers. For its application, special probes and reference calibration standards are employed. In pressurized water reactor (PWR) NPPs, a particularly critical equipment is the steam generator (SG), a huge heat exchanger that contains thousands of U-bend thin wall tubes. Due to its severe working conditions (pressure and temperature), that component is periodically examined by means of ET. In this paper a revision of the operating fundamentals of the main ET probes, used to perform SG inspections is presented. (author)

  9. Test requirements for the integral effect test to simulate Korean PWR plants

    International Nuclear Information System (INIS)

    Song, Chul Hwa; Park, C. K.; Lee, S. J.; Kwon, T. S.; Yun, B. J.; Chung, M. K.

    2001-02-01

    In this report, the test requirements are described for the design of the integral effect test facility to simulate Korean PWR plants. Since the integral effect test facility should be designed so as to simulate various thermal hydraulic phenomena, as closely as possible, to be occurred in real plants during operation or anticipated transients, the design and operational characteristics of the reference plants (Korean Standard Nuclear Plant and Korean Next Generation Reactor)were analyzed in order to draw major components, systems, and functions to be satisfied or simulated in the test facility. The test matrix is set up by considering major safety concerns of interest and the test objectives to confirm and enhance the safety of the plants. And the analysis and prioritization of the test matrix leads to the general design requirements of the test facility. Based on the general design requirements, the design criteria is set up for the basic and detailed design of the test facility. And finally it is drawn the design requirements specific to the fluid system and measurement system of the test facility. The test requirements in this report will be used as a guideline to the scaling analysis and basic design of the test facility. The test matrix specified in this report can be modified in the stage of main testing by considering the needs of experiments and circumstances at that time

  10. Continuous improvement of operation and maintenance conditions of French PWR nuclear islands

    International Nuclear Information System (INIS)

    Bitsch, D.

    1985-01-01

    Improvement of nuclear island design to facilitate maintenance and working conditions during plant shutdown has been a subject of particular attention in the French PWR programme. Standardization and industrial concentration created an unusually favourable situation for approaching this objective. Progress efforts supported by the feedback of actual operating experience were pursued in areas of plant layout equipment installation, and on the design and technology of the components themselves. When compared with units of the three-loop series currently in operation, the evolution of the latest nuclear island designs covers such layout features as better segregation and separation between systems, easier access in special areas, installation of new cleaning systems, etc. Progress efforts on the design and technology of components were pursued along several paths including: (a) the increase in resistance of specific parts submitted to various forms of in-service degradation, for example, steam generator tubes, reactor coolant pump seals, reactor control cluster drive lines and some auxiliary equipment; (b) reduction of the extent and duration of work during plant outages (fuel handling, in-service inspection, maintenance) by facilitating disassembly, removal, handling and storage of equipment parts; (c) reduction of occupational radiation exposure, one of the most important axes of development, by the appropriate selection of less activity-releasing materials such as Inconel 690 for the steam generator tubes, implementation of more efficient decontamination systems and use of robots. (author)

  11. Replacement of Co-base alloy for radiation exposure reduction in the primary system of PWR

    International Nuclear Information System (INIS)

    Han, Jeong Ho; Nyo, Kye Ho; Lee, Deok Hyun; Lim, Deok Jae; Ahn, Jin Keun; Kim, Sun Jin

    1996-01-01

    Of numerous Co-free alloys developed to replace Co-base stellite used in valve hardfacing material, two iron-base alloys of Armacor M and Tristelle 5183 and one nickel-base alloy of Nucalloy 488 were selected as candidate Co-free alloys, and Stellite 6 was also selected as a standard hardfacing material. These four alloys were welded on 316SS substrate using TIG welding method. The first corrosion test loop of KAERI simulating the water chemistry and operation condition of the primary system of PWR was designed and fabricated. Corrosion behaviors of the above four kinds of alloys were evaluated using this test loop under the condition of 300 deg C, 1500 psi. Microstructures of weldment of these alloys were observed to identify both matrix and secondary phase in each weldment. Hardnesses of weld deposit layer including HAZ and substrate were measured using micro-Vickers hardness tester. The status on the technology of Co-base alloy replacement in valve components was reviewed with respect to the classification of valves to be replaced, the development of Co-free alloys, the application of Co-free alloys and its experiences in foreign NPPs, and the Co reduction program in domestic NPPs and industries. 18 tabs., 20 figs., 22 refs. (Author)

  12. Test requirements for the integral effect test to simulate Korean PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chul Hwa; Park, C. K.; Lee, S. J.; Kwon, T. S.; Yun, B. J.; Chung, M. K

    2001-02-01

    In this report, the test requirements are described for the design of the integral effect test facility to simulate Korean PWR plants. Since the integral effect test facility should be designed so as to simulate various thermal hydraulic phenomena, as closely as possible, to be occurred in real plants during operation or anticipated transients, the design and operational characteristics of the reference plants (Korean Standard Nuclear Plant and Korean Next Generation Reactor)were analyzed in order to draw major components, systems, and functions to be satisfied or simulated in the test facility. The test matrix is set up by considering major safety concerns of interest and the test objectives to confirm and enhance the safety of the plants. And the analysis and prioritization of the test matrix leads to the general design requirements of the test facility. Based on the general design requirements, the design criteria is set up for the basic and detailed design of the test facility. And finally it is drawn the design requirements specific to the fluid system and measurement system of the test facility. The test requirements in this report will be used as a guideline to the scaling analysis and basic design of the test facility. The test matrix specified in this report can be modified in the stage of main testing by considering the needs of experiments and circumstances at that time.

  13. Development of the new basic correlation “MG-S” for CHF prediction of the PWR fuels

    Energy Technology Data Exchange (ETDEWEB)

    Yodo, T.; Sato, Y.; Yumura, T.; Makino, Y.; Suemura, T. [Mitsubishi Heavy Industries, LTD., Kobe, Hyogo (Japan)

    2011-07-01

    It is important for core thermal-hydraulic design and plant safety analysis of PWR (Pressurized Water Reactor) to predict CHF (Critical Heat Flux) accurately. The accurate CHF prediction can enhance the reliability of the safety analysis and bring more efficient plant operations such as up-rating and higher burn-up fuel management. The new CHF correlation, MG-S (Mitsubishi Generalized correlation - for Standard grid), has been developed as a basic correlation of the new correlation series, which are for conventional and new-generation Mitsubishi fuel assemblies. Through comparisons with existing CHF data and a conventional CHF correlation, it was confirmed that MG-S can predict CHF with sufficient accuracy and extend its applicability to wider fluid parameters of interest. (author)

  14. Probes for inspections of heat exchanges installed at nuclear power plants type PWR by eddy current method

    International Nuclear Information System (INIS)

    Silva, Alonso F.O.

    2007-01-01

    From all non destructive examination methods usable to perform integrity evaluation of critical equipment installed at nuclear power plants (NPP), eddy current test (ET) may be considered the most important one, when examining heat exchangers. For its application, special probes and reference calibration standards are employed. In pressurized water reactor (PWR) NPPs, a particularly critical equipment is the steam generator (SG), a huge heat exchanger that contains thousands of U-bend thin wall tubes. Due to its severe working conditions (pressure and temperature), that component is periodically examined by means of ET. In this paper a revision of the operating fundamentals of the main ET probes, used to perform SG inspections is presented. (author)

  15. Scoping Study Investigating PWR Instrumentation during a Severe Accident Scenario

    Energy Technology Data Exchange (ETDEWEB)

    Rempe, J. L. [Rempe and Associates, LLC, Idaho Falls, ID (United States); Knudson, D. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lutz, R. J. [Lutz Nuclear Safety Consultant, LLC, Asheville, NC (United States)

    2015-09-01

    The accidents at the Three Mile Island Unit 2 (TMI-2) and Fukushima Daiichi Units 1, 2, and 3 nuclear power plants demonstrate the critical importance of accurate, relevant, and timely information on the status of reactor systems during a severe accident. These events also highlight the critical importance of understanding and focusing on the key elements of system status information in an environment where operators may be overwhelmed with superfluous and sometimes conflicting data. While progress in these areas has been made since TMI-2, the events at Fukushima suggests that there may still be a potential need to ensure that critical plant information is available to plant operators. Recognizing the significant technical and economic challenges associated with plant modifications, it is important to focus on instrumentation that can address these information critical needs. As part of a program initiated by the Department of Energy, Office of Nuclear Energy (DOE-NE), a scoping effort was initiated to assess critical information needs identified for severe accident management and mitigation in commercial Light Water Reactors (LWRs), to quantify the environment instruments monitoring this data would have to survive, and to identify gaps where predicted environments exceed instrumentation qualification envelop (QE) limits. Results from the Pressurized Water Reactor (PWR) scoping evaluations are documented in this report. The PWR evaluations were limited in this scoping evaluation to quantifying the environmental conditions for an unmitigated Short-Term Station BlackOut (STSBO) sequence in one unit at the Surry nuclear power station. Results were obtained using the MELCOR models developed for the US Nuclear Regulatory Commission (NRC)-sponsored State of the Art Consequence Assessment (SOARCA) program project. Results from this scoping evaluation indicate that some instrumentation identified to provide critical information would be exposed to conditions that

  16. Issues and remedies for secondary system of PWR/VVER

    International Nuclear Information System (INIS)

    Nordmann, Francis; Odar, Suat; Rochester, Dewey

    2012-09-01

    Secondary side degradation of steam generators (SG) and Flow Accelerated Corrosion (FAC) in the secondary system have been for a long time important issues in PWR and VVER types of Nuclear Power Plants. With the evolution of the design, the most important issues are progressively moving from secondary side corrosion of Alloy 600 SG tubing, which is being replaced, to a larger variety of risks associated with potential inadequate chemistries. As far as FAC of carbon steel is concerned, the evolution of treatment selection for minimizing corrosion products transport toward the SG, as well as progressive replacement of components in the feedwater train, decreases the risk of dramatic failures which have occurred in the past. After having briefly explained the reason for the past problems encountered in the secondary system of PWR and VVER, this paper evaluates the risk associated with various impurities or contaminants that may be present in the secondary system and how to mitigate them in the most appropriate, efficient, economical and environmental friendly way. The covered species are sodium, calcium, magnesium, chloride, sulfate and sulfur compounds, fluorides, organic compounds, silica, oxygen, lead, ion exchange resins. This paper also proposes the best remedies for mitigating the new issues that may be encountered in operating plants or units under construction. These are mainly: - Selecting a steam water treatment able to minimize the quantity of corrosion products transported toward the SG; - Mitigating the risk of Flow Induced Vibration by a proper control of deposits in sensitive areas; - Minimizing the risk of concentration of impurities in local areas where they may induce corrosion; - Avoiding the presence of abnormal quantities of some species in SG, such as the detrimental presence of lead and ion exchange resin debris or the controversial presence of organic compounds; - Optimizing costs of maintenance activities (SG mechanical, chemical cleaning

  17. The increase in fatigue crack growth rates observed for Zircaloy-4 in a PWR environment

    Science.gov (United States)

    Cockeram, B. V.; Kammenzind, B. F.

    2018-02-01

    Cyclic stresses produced during the operation of nuclear reactors can result in the extension of cracks by processes of fatigue. Although fatigue crack growth rate (FCGR) data for Zircaloy-4 in air are available, little testing has been performed in a PWR primary water environment. Test programs have been performed by Gee et al., in 1989 and Picker and Pickles in 1984 by the UK Atomic Energy Authority, and by Wisner et al., in 1994, that have shown an enhancement in FCGR for Zircaloy-2 and Zircaloy-4 in high-temperature water. In this work, FCGR testing is performed on Zircaloy-4 in a PWR environment in the hydrided and non-hydrided condition over a range of stress-intensity. Measurements of crack extension are performed using a direct current potential drop (DCPD) method. The cyclic rate in the PWR primary water environment is varied between 1 cycle per minute to 0.1 cycle per minute. Faster FCGR rates are observed in water in comparison to FCGR testing performed in air for the hydrided material. Hydrided and non-hydrided materials had similar FCGR values in air, but the non-hydrided material exhibited much lower rates of FCGR in a PWR primary water environment than for hydrided material. Hydrides are shown to exhibit an increased tendency for cracking or decohesion in a PWR primary water environment that results in an enhancement in FCGR values. The FCGR in the PWR primary water only increased slightly with decreasing cycle frequency in the range of 1 cycle per minute to 0.1 cycle per minute. Comparisons between the FCGR in water and air show the enhancement from the PWR environment is affected by the applied stress intensity.

  18. The deformation of PWR fuel in a LOCA

    International Nuclear Information System (INIS)

    Mann, C.A.; Hindle, E.D.; Parsons, P.D.

    1982-04-01

    Available world-wide published data on the deformation of PWR fuel in a loss-of-coolant accident are reviewed. Adequate data exist for the oxidation of Zircaloy up to about 1500 0 C; data are increasingly sparse above this temperature and lacking above the melting point. The US NRC criteria for embrittlement are discussed and considered adequate for undeformed cladding, though they may be less so for deformed thinned material. Cladding deformation and the factors controlling it are considered in the light of data from the US, Germany, Japan and the UK. It is concluded that strains in the range 30% - 70% can be produced in experiments simulating LOCA conditions. The behaviour of cladding is strongly influenced by the spatial distribution of temperature, which is in turn dependent on heat transfer mechanisms at the surfaces of the cladding. No realistic experiment, i.e. one with a multirod array and simulated cooling, has produced deformations which would inhibit quenching. Such experiments have not, however, as yet covered the entire range of conditions which might obtain following a LOCA. (author)

  19. Sizewell B: consent application for Britain's first PWR power station

    International Nuclear Information System (INIS)

    1981-02-01

    The Central Electricity Generating Board has applied to the Secretary of State for Energy for consent and for other necessary permissions to construct a nuclear power station of about 1200 MW output capacity based on the pressurised water reactor (PWR) system on the Board's existing site at Sizewell (near Leiston) in Suffolk to be known as Sizewell B. Application has also been made to the Health and Safety Executive to extend the existing nuclear site licence to permit the use of the site for a pressurised water reactor. The Secretary of State for Energy has already stated that a Public Inquiry will be held into the application and this is expected to take place in 1982. The Board is making these applications now to give ample time for public discussion and consultation. Construction of the station could not begin until the outcome of the Public Inquiry is known and the necessary consents, nuclear licence and clearances have been given. The text of the application is presented. Some background information is given. (author)

  20. Effect of component aging on PWR control rod drive systems

    International Nuclear Information System (INIS)

    Grove, E.; Gunther, W.; Sullivan, K.

    1992-01-01

    An aging assessment of PWR control rod drive (CRD) systems has been completed as part of the US NRC Nuclear Plant Aging Research (NPAR) Program. The design, construction, maintenance, and operation of the Babcock ampersand Wilcox (B ampersand W), Combustion Engineering (CE), and Westinghouse (W) systems were evaluated to determine the potential for degradation as each system ages. Operating experience data were evaluated to identify the predominant failure modes, causes, and effects. This, coupled with an assessment of the materials of construction and operating environment, demonstrate that each design is subject to degradation, which if left unchecked, could affect its safety function as the plant ages. An industry survey, conducted with the assistance of EPRI and NUMARC, identified current CRD system maintenance and inspection practices. The results of this survey indicate that some plants have performed system modifications, replaced components, or augmented existing preventive maintenance practices in response to system aging. The survey results also supported the operating experience data, which concluded that the timely replacement of degraded components, prior to failure, was not always possible using existing condition monitoring techniques. The recommendations presented in this study also include a discussion of more advanced monitoring techniques, which provide trendable results capable of detecting aging

  1. Plutonium thermal utilization in PWR in Mihama No. 1 plant

    International Nuclear Information System (INIS)

    Yokote, Mitsuhiro; Kondo, Yoshiaki; Shimada, Shouichirou; Abeta, Sadaaki.

    1992-01-01

    On December 20, 1991, the use of four MOX fuels charged in Mihama No. 1 plant for three cycles ended, which is the verification project with small number of specimens on the plutonium thermal utilization in PWRs in Japan. There was not any symptom of showing abnormality in the safety of the core and the soundness of the fuel during the use. In this report, the verification project and the results are explained. In spent fuel, reusable fission substances such as Pu-239 and Pu-241 produced from U-235 and U-238 are contained. By recycling and effectively utilizing them, resources are protected and the effect to environment is reduced, the energy security in Japan with poor resources can be heightened, and waste management becomes proper. The course of the plutonium thermal utilization in PWR project in Mihama No. 1 plant, the design of MOX fuel and the core, the manufacture of MOX fuel in USA and its transport to Japan, the preservation, practical use and operation management of MOX fuel, the charging of MOX fuel in Mihama No. 1 plant and the use, and the plan of the plutonium thermal utilization in PWRs for hereafter are reported. (K.I.)

  2. Fluid-structure interactions in PWR vessels during blowdown

    International Nuclear Information System (INIS)

    Schumann, U.; Enderle, G.; Katz, F.; Ludwig, A.; Moesinger, H.; Schlechtendahl, E.G.

    1979-01-01

    For analysis of blowdown loadings and dynamic response of PWR vessel internals several computer codes have been developed at Karlsruhe. The goal is to provide advanced codes which permit a 'best estimate' analysis of the deformations and stresses of the internal structures, in particular the core barrel, such that the safety margins can be evaluated. The stresses reach their maxima during the initial subcooled period of the blowdown in which two-phase phenomena are important in the blowdown pipe only. In this period, the computed results with and without fluid-structural interactions show that the coupling between the water in the downcomer and the rather thin elastic core barrel is of dominant importance. Without coupling the core barrel oscillates with much higher frequencies than with coupling. The amplitudes and stresses are about twice as large initially. Later, the decoupled analysis can result in a meaningless overestimation of the structural response. By comparison of computations for incompressible and for compressible fluid with and without coupling we have found that a correct treatment of the fluid-structure coupling is more important than the description of pressure waves. (orig.)

  3. Optimal design of passive containment cooling system for innovative PWR

    Directory of Open Access Journals (Sweden)

    Huiun Ha

    2017-08-01

    Full Text Available Using the Generation of Thermal-Hydraulic Information for Containments (GOTHIC code, thermal-hydraulic phenomena that occur inside the containment have been investigated, along with the preliminary design of the passive containment cooling system (PCCS of an innovative pressurized water reactor (PWR. A GOTHIC containment model was constructed with reference to the design data of the Advanced Power Reactor 1400, and report related PCCS. The effects of the design parameters were evaluated for passive containment cooling tank (PCCT geometry, PCCS heat exchanger (PCCX location, and surface area. The analyzed results, obtained using the single PCCT, showed that repressurization and reheating phenomena had occurred. To resolve these problems, a coupled PCCT concept was suggested and was found to continually decrease the containment pressure and temperature without repressurization and reheating. If the installation level of the PCCX is higher than that of the PCCT, it may affect the PCCS performance. Additionally, it was confirmed that various means of increasing the external surface area of the PCCX, such as fins, could help improve the energy removal performance of the PCCS. To improve the PCCS design and investigate its performance, further studies are needed.

  4. Optimal design of passive containment cooling system for innovative PWR

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Huiun; Lee, Sang Won; Kim, Hangon [Central Research Institute, Korea Hydro and Nuclear Power, Ltd., Daejeon (Korea, Republic of)

    2017-08-15

    Using the Generation of Thermal-Hydraulic Information for Containments (GOTHIC) code, thermal-hydraulic phenomena that occur inside the containment have been investigated, along with the preliminary design of the passive containment cooling system (PCCS) of an innovative pressurized water reactor (PWR). A GOTHIC containment model was constructed with reference to the design data of the Advanced Power Reactor 1400, and report related PCCS. The effects of the design parameters were evaluated for passive containment cooling tank (PCCT) geometry, PCCS heat exchanger (PCCX) location, and surface area. The analyzed results, obtained using the single PCCT, showed that repressurization and reheating phenomena had occurred. To resolve these problems, a coupled PCCT concept was suggested and was found to continually decrease the containment pressure and temperature without repressurization and reheating. If the installation level of the PCCX is higher than that of the PCCT, it may affect the PCCS performance. Additionally, it was confirmed that various means of increasing the external surface area of the PCCX, such as fins, could help improve the energy removal performance of the PCCS. To improve the PCCS design and investigate its performance, further studies are needed.

  5. Optimal design of passive containment cooling system for innovative PWR

    International Nuclear Information System (INIS)

    Ha, Huiun; Lee, Sang Won; Kim, Hangon

    2017-01-01

    Using the Generation of Thermal-Hydraulic Information for Containments (GOTHIC) code, thermal-hydraulic phenomena that occur inside the containment have been investigated, along with the preliminary design of the passive containment cooling system (PCCS) of an innovative pressurized water reactor (PWR). A GOTHIC containment model was constructed with reference to the design data of the Advanced Power Reactor 1400, and report related PCCS. The effects of the design parameters were evaluated for passive containment cooling tank (PCCT) geometry, PCCS heat exchanger (PCCX) location, and surface area. The analyzed results, obtained using the single PCCT, showed that repressurization and reheating phenomena had occurred. To resolve these problems, a coupled PCCT concept was suggested and was found to continually decrease the containment pressure and temperature without repressurization and reheating. If the installation level of the PCCX is higher than that of the PCCT, it may affect the PCCS performance. Additionally, it was confirmed that various means of increasing the external surface area of the PCCX, such as fins, could help improve the energy removal performance of the PCCS. To improve the PCCS design and investigate its performance, further studies are needed

  6. Break location effects on PWR small break LOCA phenomena

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro

    1989-01-01

    The report presents experimental results of a small lower plenum break test of SB-PV-01 conducted at the large-Scale Test Facility (LSTF) of the Rig-of-Safety Assessment (ROSA)-IV program. This test simulates a loss-of-coolant accident (LOCA) caused by instrument tubes break (break area corresponds to 0.5% of the cold leg flow area) in a Westinghouse-type pressurized water reactor (PWR) assuming both manual actuation for all of the high pressure injection (HPI) systems and failure of the auxiliary feedwater systems. The report clarifies long-term system responses, especially the core cooling conditions related to the primary mass inventory. Also it clarifies break location effects on small break LOCA phenomena by comparing other five similar LOCA tests with break locations at cold leg, hot leg, upper head, pressurizer top (TMI-type) and SG U-tubes. It is coucluded that the lower plenum break is the severest on core heatup due to the highest break flow rate and the least primary mass recovery after the ECCS among the six tests. (author)

  7. Source term aspects associated with future PWR containment systems

    International Nuclear Information System (INIS)

    Kuczera, B.; Kebler, G.; Ehrhardt, J.; Scholtyssek, W.

    1994-01-01

    The overall objective of reactor safety is to protect the population against dangerous releases of radioactive materials from nuclear power plants. In context with a reinforcement of the defense-in-depth strategy the common safety requirements on future nuclear power plants converge in the objective that these plants should be so safe that even in case of a severe accident there will be no need of off-site emergency actions such as an evacuation or resettlement of the population from the vicinity of a nuclear power plant. It is shown by the example of a future 1400 MWe pressurized water reactor (PWR) plant that this goal can be attained in principle by providing a double containment with the annulus vented via an appropriate emergency standby filter. Within the framework of severe accident consequence mitigation a set of parameters for accident conditions and emergency filter efficiencies is elaborated under which the German lower levels of intervention for evacuation are not attained. (author). 10 refs., 3 tabs., 5 figs

  8. Structural integrity evaluation of PWR nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Cruz, Julio R.B.; Mattar Neto, Miguel

    1999-01-01

    The reactor pressure vessel (RPV) is the most important structural component of a PWR nuclear power plant. It contains the reactor core and is the main component of the primary system pressure boundary, the system responsible for removing the heat generated by the nuclear reactions. It is considered not replaceable and, therefore, its lifetime is a key element to define the plant life as a whole. Three critical issues related to the reliability of the RPV structural integrity come out by reason of the radiation damage imposed to the vessel material during operation. These issues concern the definition of pressure versus temperature limits for reactor heatup and cooldown, pressurized thermal shock evaluation and assessment of reactor vessels with low upper shelf Charpy impact energy levels. This work aims to present the major aspects related to these topics. The requirements for preventing fracture of the RPV are reviewed as well as the available technology for assessing the safety margins. For each mentioned problem, the several steps for structural integrity evaluation are described and the analysis methods are discussed. (author)

  9. Aerosols behavior inside a PWR during an accident

    International Nuclear Information System (INIS)

    Hervouet, C.

    1983-01-01

    During very hypothetical accidents occurring in a pressurized water ractor, radioactive aerosols can be released, during core-melt, inside the reactor containment building. A good knowledge of their behavior in the humid containment atmosphere (mass concentration and size distribution) is essential in order to evaluate their harmfulness in case of environment contamination and to design possible filtration devices. Accordingly the Safety Analysis Department of the Atomic Energy Commission uses several computer models, describing the particle formation (BOIL/MARCH), then behavior in the primary circuits (TRAP-MELT), and in the reactor containment building (AEROSOLS-PARFDISEKO-III B). On the one hand, these models have been improved, in particular the one related to the aerosol formation (nature and mass of released particles) using recent experimental results. On the other hand, sensitivity analyses have been performed with the AEROSOLS code which emphasize the particle coagulation parameters: agglomerate shape factors and collision efficiency. Finally, the different computer models have been applied to the study of aerosol behavior during a 900 MWe PWR accident: loss-of-coolant-accident (small break with failure of all safety systems) [fr

  10. Water chemistry control of PWR nuclear power plant

    International Nuclear Information System (INIS)

    Hino, Yuichi; Makino, Ichiro; Yamauchi, Sumio; Fukuda, Fumihito.

    1992-01-01

    In PWR power plants, the primary system taking heat out of nuclear reactors and the secondary system generating steam and driving turbines are completely separated by steam generators, accordingly, by mutually independent water treatment, both systems are to be maintained in the optimal conditions. Namely, primary system is the closed water circulation circuit of simple liquid phase though under high temperature, high pressure condition, therefore, water shows the stable physical and chemical properties, and the minute water treatment for restraining the corrosion of structural materials and reducing radioactivity can be done. Secondary system is similar to the condensate and feedwater system of thermal power plants, and is the circuit for liquid-vapor two-phase transformation, but due to the local concentration of impurities by evaporation, the strict requirement is set for secondary water quality. However, secondary system can be treated in the state without radioactivity, and this is a great merit. The outline, basic concept and execution of primary water quality control, and the outline, concept, control criteria, facilities and execution of secondary water quality control are reported. (K.I.)

  11. Improvements of nuclear fuel management in pressurized water reactors (PWR)

    International Nuclear Information System (INIS)

    Schwartz, J.P.

    1978-07-01

    The severe variations to which the different elements contributing to the determination of the fuel cycle cost are subjected have led to a reopening of the problem of ''optimization'' of nuclear fuel management. The increase in costs of uranium ore, isotope separation work units (swu), reprocessing, the political implications of proliferation associated with the employment of reprocessing operations have been at the origin of a reassessment of present-day management. It therefore appeared to be appropriate to study variants with respect to a reference mode represented by the management of the PWR 900 MWe systems, without burnable poison in the cycle at equilibrium (Case 3 of Table 1). In order to obtain a complete view of impacts of such modifications, computations were carried out as far as the appraisal of the cycle cost and with reprocessing. There has likewise been added to this the estimate of the gain anticipated from certain improvements in the neutron balance contributed at the level of the lattice

  12. Integrated training support system for PWR operator training simulator

    International Nuclear Information System (INIS)

    Sakaguchi, Junichi; Komatsu, Yasuki

    1999-01-01

    The importance of operator training using operator training simulator has been recognized intensively. Since 1986, we have been developing and providing many PWR simulators in Japan. We also have developed some training support systems connected with the simulator and the integrated training support system to improve training effect and to reduce instructor's workload. This paper describes the concept and the effect of the integrated training support system and of the following sub-systems. We have PES (Performance Enhancement System) that evaluates training performance automatically by analyzing many plant parameters and operation data. It can reduce the deviation of training performance evaluation between instructors. PEL (Parameter and Event data Logging system), that is the subset of PES, has some data-logging functions. And we also have TPES (Team Performance Enhancement System) that is used aiming to improve trainees' ability for communication between operators. Trainee can have conversation with virtual trainees that TPES plays automatically. After that, TPES automatically display some advice to be improved. RVD (Reactor coolant system Visual Display) displays the distributed hydraulic-thermal condition of the reactor coolant system in real-time graphically. It can make trainees understand the inside plant condition in more detail. These sub-systems have been used in a training center and have contributed the improvement of operator training and have gained in popularity. (author)

  13. Advanced methods for the study of PWR cores

    International Nuclear Information System (INIS)

    Lambert, M.; Salvatores, St.; Ferrier, A.; Pelet, J.; Nicaise, N.; Pouliquen, J.Y.; Foret, F.; Chauliac, C.; Johner, J.; Cohen, Ch.

    2003-01-01

    This document gathers the transparencies presented at the 6. technical session of the French nuclear energy society (SFEN) in October 2003. The transparencies of the annual meeting are presented in the introductive part: 1 - status of the French nuclear park: nuclear energy results, management of an exceptional climatic situation: the heat wave of summer 2003 and the power generation (J.C. Barral); 2 - status of the research on controlled thermonuclear fusion (J. Johner). Then follows the technical session about the advanced methods for the study of PWR reactor cores: 1 - the evolution approach of study methodologies (M. Lambert, J. Pelet); 2 - the point of view of the nuclear safety authority (D. Brenot); 3 - the improved decoupled methodology for the steam pipe rupture (S. Salvatores, J.Y. Pouliquen); 4 - the MIR method for the pellet-clad interaction (renovated IPG methodology) (E. Baud, C. Royere); 5 - the improved fuel management (IFM) studies for Koeberg (C. Cohen); 6 - principle of the methods of accident study implemented for the European pressurized reactor (EPR) (F. Foret, A. Ferrier); 7 - accident studies with the EPR, steam pipe rupture (N. Nicaise, S. Salvatores); 8 - the co-development platform, a new generation of software tools for the new methodologies (C. Chauliac). (J.S.)

  14. Robots in P.W.R. nuclear powerplants

    International Nuclear Information System (INIS)

    Dubourg, M.

    1987-01-01

    The satisfactory operation of 37 900-MWe PWR powerplants in France, Belgium and South-Africa and the start-up of 1300 MWe powerplants allowed the development of a wide range of automatic units and robots for the periodic maintenance of nuclear plants, reducing the risk of ionizing radiation for the personnel. A large number of automated tools have been built. Among them: - inspection and maintenance systems for the tube bundle of steam generators, - robotized arms ROTETA and ROMEO for the heavy maintenance and delicate operations such as tube extraction or shot peening of tubes to improve their resistance to corrosion; - the versatile manipulator T.A.M. with electrically controlled articulations. The development of functionally versatile tools and robots and the integration of new technologies such as 3-D vision allowed the construction of the self-guided vehicle FRASTAR capable of moving within a nuclear building and in a cluttered environment. This vehicle includes means for avoiding isolated obstacles and can move on stairs [fr

  15. Applicability of oxygenated water chemistry for PWR secondary systems

    Energy Technology Data Exchange (ETDEWEB)

    Hermansson, H.P. [Studsvik Nuclear AB, Nykoeping (Sweden); Takiguchi, H.; Otoha, K. [Japan Atomic Power Co., Tokyo (Japan)

    2002-07-01

    Introduction of oxygenated water chemistry (OWC) in PWR secondary side is considered as a means to reduce the transportation of corrosion products into the steam generator and thus also minimizing crevice deposits and subsequent materials problems. One main concern, however, is the risk of inter-granular attack (IGA) in crevices. In order to study effects on crevice tube IGA by OWC, a series of experiments were performed in a steam generator (SG) simulating loop. This comprised a SG tube and a tube support plate (TSP) together forming the crevice. The over-all objective of the work accounted here was to demonstrate that it is possible to operate the steam generator secondary side with OWC without causing intolerable IGA or other types of attack on the tube in the crevice area. Tubes of sensitized Alloy 600 were exposed during a total of nine experiments in an autoclave using a TSP/tube arrangement with an asymmetric crevice design. Experiments were performed at high and low pH and potential under open and packed crevice conditions. The aggressiveness of the crevice environment was also further increased by addition of carbonate and chloride. Furthermore the tube was pressurized. Experimental parameters were monitored on the primary side as well as in the secondary bulk phase and in the crevice. (authors)

  16. PWR loading pattern optimization using Harmony Search algorithm

    International Nuclear Information System (INIS)

    Poursalehi, N.; Zolfaghari, A.; Minuchehr, A.

    2013-01-01

    Highlights: ► Numerical results reveal that the HS method is reliable. ► The great advantage of HS is significant gain in computational cost. ► On the average, the final band width of search fitness values is narrow. ► Our experiments show that the search approaches the optimal value fast. - Abstract: In this paper a core reloading technique using Harmony Search, HS, is presented in the context of finding an optimal configuration of fuel assemblies, FA, in pressurized water reactors. To implement and evaluate the proposed technique a Harmony Search along Nodal Expansion Code for 2-D geometry, HSNEC2D, is developed to obtain nearly optimal arrangement of fuel assemblies in PWR cores. This code consists of two sections including Harmony Search algorithm and Nodal Expansion modules using fourth degree flux expansion which solves two dimensional-multi group diffusion equations with one node per fuel assembly. Two optimization test problems are investigated to demonstrate the HS algorithm capability in converging to near optimal loading pattern in the fuel management field and other subjects. Results, convergence rate and reliability of the method are quite promising and show the HS algorithm performs very well and is comparable to other competitive algorithms such as Genetic Algorithm and Particle Swarm Intelligence. Furthermore, implementation of nodal expansion technique along HS causes considerable reduction of computational time to process and analysis optimization in the core fuel management problems

  17. RCC-CW - Rules for design and construction of PWR nuclear civil works

    International Nuclear Information System (INIS)

    2016-01-01

    RCC-CW describes the rules for designing, building and testing civil engineering works in PWR reactors. It explains the principles and requirements for the safety, serviceability and durability of concrete and metal frame structures, based on Eurocode design principles (European standards for the structural design of construction works) combined with specific measures for safety-class buildings. The code is produced as part of the RCC-CW Subcommittee, which includes all the parties involved in civil engineering works in the nuclear sector: clients, contractors, general and specialized firms, consultancies and inspection offices. The code covers the following areas relating to the design and construction of civil engineering works that play an important safety role: geotechnical aspects, reinforced concrete structures and galleries, pre-stressed containments with metal liner, metal containment and pool liners, metal frames, anchors, concrete cylinder pipes, containment leak tests. The RCC-CW code is available as an ETC-C version specific to EPR projects (European pressurized reactor). Contents of the 2016 edition of the RCC-CW Code: Part G - General: scope, standards, notations, quality management, general principles; Part D - Design: actions and combinations of actions, geotechnical aspects, pre-stressed or reinforced concrete structures, metal containment liners, metal pool liners, metal frames, anchors; Part C - Construction: geotechnical aspects, concrete, surface finish and formwork, reinforcement for reinforced concrete, pre-stressing processes, prefabricated concrete elements, metal containment liners, metal pool liners, metal frames, anchors, embedded pipelines, joint sealing, survey networks and tolerances; Part M - Maintenance and monitoring: containment integrity and rate tests

  18. Preliminary safety analysis of the PWR with accident-tolerant fuels during severe accident conditions

    International Nuclear Information System (INIS)

    Wu, Xiaoli; Li, Wei; Wang, Yang; Zhang, Yapei; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng; Liu, Tong; Deng, Yongjun; Huang, Heng

    2015-01-01

    Highlights: • Analysis of severe accident scenarios for a PWR fueled with ATF system is performed. • A large-break LOCA without ECCS is analyzed for the PWR fueled with ATF system. • Extended SBO cases are discussed for the PWR fueled with ATF system. • The accident-tolerance of ATF system for application in PWR is illustrated. - Abstract: Experience gained in decades of nuclear safety research and previous nuclear accidents direct to the investigation of passive safety system design and accident-tolerant fuel (ATF) system which is now becoming a hot research point in the nuclear energy field. The ATF system is aimed at upgrading safety characteristics of the nuclear fuel and cladding in a reactor core where active cooling has been lost, and is preferable or comparable to the current UO 2 –Zr system when the reactor is in normal operation. By virtue of advanced materials with improved properties, the ATF system will obviously slow down the progression of accidents, allowing wider margin of time for the mitigation measures to work. Specifically, the simulation and analysis of a large break loss of coolant accident (LBLOCA) without ECCS and extended station blackout (SBO) severe accident are performed for a pressurized water reactor (PWR) loaded with ATF candidates, to reflect the accident-tolerance of ATF

  19. PWR-PSMS benchmarking results using thermocouple data from the summer-1 plant

    International Nuclear Information System (INIS)

    Peng, C.M.; Ipakchi, A.; Kim, J.H.

    1986-01-01

    In large pressurized water reactor (PWR) power plants, estimating the in-core power distribution from off-line predictions is based on data from global measurements with conservative assumptions. The off-line predictions are too independent of the actual process to reflect the true state of the reactor. The on-line core monitoring systems tend to balance between measurements and theoretical calculations, better utilizing information coming from measurements. The hybrid system, which incorporates measurements in predictions along with frequent model adaptations, will closely track the actual operating state of the plant. Since the detailed core flux mapping is performed with large time intervals for those PWRs without fixed in-core detectors, the on-line signals from thermocouples located at the top of selected fuel assemblies offer an alternative means of monitoring. The in-core thermocouples give a good indication of the average coolant temperature at the outlet of the instrumented assemblies and potentially can provide continuous information of the radial power distribution between flux maps. The PWR Power Shape Monitoring System (PWR-PSMS) has implemented this on-line monitoring feature based on thermocouple readings to evaluate the core performance and to improve core monitoring. The purpose of this paper is to present the benchmark results of PWR-PSMS using thermocouple data from the Summer-1 plant of a Westinghouse PWR

  20. Definition of thermal-hydraulics parameters of a naval PWR via energy balance of a Westinghouse PWR

    International Nuclear Information System (INIS)

    Chaves, Luiz C.; Curi, Marcos F.

    2017-01-01

    In this work, we used the operational parameters of the Angra 1 nuclear power plant, designed by Westinghouse, to estimate the thermal-hydraulic parameters for naval nuclear propulsion, focusing on the analysis of the reactor and steam generator. A thermodynamics analysis was made to reach the operational parameters of primary circuit such as pressure, temperature, power generated among others. Previous studies available in literature of 2-loop Westinghouse Nuclear Power Plants, which is based on a PWR and similar to Angra-1, support this analysis in the sense of a correct procedure to deal with many complex processes to energy generation from a nuclear source. Temperature profiles in reactor and steam generator were studied with concepts of heat transfer, fluid mechanics and also some concepts of nuclear systems, showing the behavior into them. In this simulation, the Angra 1 primary circuit was reduced on a scale of 1: 3.5 to fit in a Scorpène-class submarine. The reactor generates 85.7 MW of total thermal power. The maximum power and temperatures reached were lower than the operational safe limits established by Westinghouse. The number of tubes of the steam generator was determined in 990 U-tubes with 6.3 m of average length. (author)

  1. Definition of thermal-hydraulics parameters of a naval PWR via energy balance of a Westinghouse PWR

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Luiz C.; Curi, Marcos F., E-mail: marcos.curi@cefet-rj.br [Centro Federal de Educação Tecnológica Celso Suckow da Fonseca (CEFET-RJ), Rio de Janeiro, RJ (Brazil). Department of Mechanical Engineering

    2017-07-01

    In this work, we used the operational parameters of the Angra 1 nuclear power plant, designed by Westinghouse, to estimate the thermal-hydraulic parameters for naval nuclear propulsion, focusing on the analysis of the reactor and steam generator. A thermodynamics analysis was made to reach the operational parameters of primary circuit such as pressure, temperature, power generated among others. Previous studies available in literature of 2-loop Westinghouse Nuclear Power Plants, which is based on a PWR and similar to Angra-1, support this analysis in the sense of a correct procedure to deal with many complex processes to energy generation from a nuclear source. Temperature profiles in reactor and steam generator were studied with concepts of heat transfer, fluid mechanics and also some concepts of nuclear systems, showing the behavior into them. In this simulation, the Angra 1 primary circuit was reduced on a scale of 1: 3.5 to fit in a Scorpène-class submarine. The reactor generates 85.7 MW of total thermal power. The maximum power and temperatures reached were lower than the operational safe limits established by Westinghouse. The number of tubes of the steam generator was determined in 990 U-tubes with 6.3 m of average length. (author)

  2. Status of Standardization Projects

    Science.gov (United States)

    1993-12-31

    CR SC BE 5935 3972 P-C-596- CON [EE PWR GEN SPEC FOP ESE 5 F7 94’ 953 9z3 A CR VD: BE ES N PAGE NO. A - 51 5935-5935 RCS NO. DD-OR&E(AR)759...DR&E(AR)759 STANDARDIZATION PROJECTS REPORT - 1ST QTR FY 1994 PREPARING ACTIVITY LISTING PA AAPAA p BPP .A- G/ASA NC AC 21 RC G CSOL- Qý yqFyýFT7RL AL...T-83727/1 TRANSOLVER TYPE 11.9 85 ES HE 941 9E- 5A 4,R AS F7 N 5990 0425 02 MIL-T-83727/2 TRANSOLVER TYPE 11.8 85 ES HE 941 95: 951 A Aý AS BE N 5990

  3. Hydraulic test for non-instrumented capsule of advanced PWR fuel pellet

    International Nuclear Information System (INIS)

    Jun, Hyung Gil; Yoon, Y. J.; Chun, S. Y.; Kim, D. H.; Lee, C. B.; Ryu, J.

    2001-04-01

    This report presents the results of pressure drop test, vibration test and endurance test for Non-instrumented Capsule of Advanced PWR Fuel Pellet which were designed fabricated by KAERI. From the pressure drop test results, it is noted that the flow rate across the Non-instrumented Capsule of Advanced PWR Fuel Pellet corresponding to the pressure drop of 200 kPa is measured to be about 7.45 kg/sec. Vibration frequency for the Non-instrumented Capsule of Advanced PWR Fuel Pellet ranges from 13.0 to 32.3 Hz. RMS(Root Mean Square) displacement for the fuel rig is less than 11.6 μm, and the maximum displacement is less than 30.5 μm. The endurance test was carried out for 103 days and 17 hours

  4. Sensitivity Verification of PWR Monitoring System Using Neuro-Expert For LOCA Detection

    International Nuclear Information System (INIS)

    Muhammad Subekti

    2009-01-01

    Sensitivity Verification of PWR Monitoring System Using Neuro-Expert For LOCA Detection. The present research was done for verification of previous developed method on Loss of Coolant Accident (LOCA) detection and perform simulations for knowing the sensitivity of the PWR monitoring system that applied neuro-expert method. The previous research continuing on present research, has developed and has tested the neuro-expert method for several anomaly detections in Nuclear Power Plant (NPP) typed Pressurized Water Reactor (PWR). Neuro-expert can detect the LOCA anomaly with sensitivity of primary coolant leakage of 7 gallon/min and the conventional method could not detect the primary coolant leakage of 30 gallon/min. Neuro expert method detects significantly LOCA anomaly faster than conventional system in Surry-1 NPP as well so that the impact risk is reducible. (author)

  5. Study on PCS heat and mass transfer of advanced PWR with CFD code

    Energy Technology Data Exchange (ETDEWEB)

    Huang, X. G.; Cheng, X. [Shanghai Jiao Tong Univ., Shanghai (China); Wang, F. N.; Zhang, Z. D.; Cheng, X. [State Nuclear Power Technology Company, Beijing (China)

    2012-03-15

    During the hypothetical Double-Ended Cold Leg Guillotine (DECLG) of large advanced pressure water reactor (PWR), a large amount of steam ejects from the break into the containment. Passive containment cooling system (PCS) is implemented to prevent over-pressure and over-temperature. The computational fluid dynamics (CFD) code GASFLOW coupled with Film Coverage and Evaporation Model (FICEM) is applied in this study to analyze the PCS performance during DECLG.FICEM can calculate film coverage rate, film evaporation rate and containment heat removal capability. Results show that the modified GASFLOW version coupled with FICEM is feasible to analyze the thermal-hydraulic behavior in PCS of advanced passive PWR. Capability of PCS for large scale PWR is investigated through using the modified GASFLOW code.

  6. Evaluation and categorization of secondary system layup and cleanup practices for PWR plants

    International Nuclear Information System (INIS)

    Cleary, W.F.

    1982-12-01

    The EPRI Program S113-1, Evaluation of Secondary System Layup and Cleanup Proctices was established to study ways to minimize the transport of corrosion products into the secondary side PWR steam generators that occurs during plant startups following extended outages. As part of the EPRI Program, Task 200 objective was to identify and categorize the layup and cleanup practices now in use or proposed by utilities for PWR plants. The task study consisted of gathering information by conducting site visits to fourteen representative PWR plants in the USA, Europe and Japan, by conducting a search of the open literature, reviews of related EPRI Programs, and by evaluating the practices in terms of their potential effectiveness. The results show that about 30% of the plants attempt routine layup of secondary systems during outages and about 60% perform some form of system cleanup during the return to power following extended outages

  7. Assessment of PWR Steam Generator modelling in RELAP5/MOD2. International Agreement Report

    Energy Technology Data Exchange (ETDEWEB)

    Putney, J.M.; Preece, R.J. [National Power, Leatherhead (GB). Technology and Environment Centre

    1993-06-01

    An assessment of Steam Generator (SG) modelling in the PWR thermal-hydraulic code RELAP5/MOD2 is presented. The assessment is based on a review of code assessment calculations performed in the UK and elsewhere, detailed calculations against a series of commissioning tests carried out on the Wolf Creek PWR and analytical investigations of the phenomena involved in normal and abnormal SG operation. A number of modelling deficiencies are identified and their implications for PWR safety analysis are discussed -- including methods for compensating for the deficiencies through changes to the input deck. Consideration is also given as to whether the deficiencies will still be present in the successor code RELAP5/MOD3.

  8. Assessment of PWR Steam Generator modelling in RELAP5/MOD2

    International Nuclear Information System (INIS)

    Putney, J.M.; Preece, R.J.

    1993-06-01

    An assessment of Steam Generator (SG) modelling in the PWR thermal-hydraulic code RELAP5/MOD2 is presented. The assessment is based on a review of code assessment calculations performed in the UK and elsewhere, detailed calculations against a series of commissioning tests carried out on the Wolf Creek PWR and analytical investigations of the phenomena involved in normal and abnormal SG operation. A number of modelling deficiencies are identified and their implications for PWR safety analysis are discussed -- including methods for compensating for the deficiencies through changes to the input deck. Consideration is also given as to whether the deficiencies will still be present in the successor code RELAP5/MOD3

  9. Pressurized Water Reactors (PWR) and Boiling Water Reactors (BWR) are compared

    International Nuclear Information System (INIS)

    Greneche, D.

    2014-01-01

    This article compares the 2 types of light water reactors that are used to produce electricity: the Pressurized Water Reactor (PWR) and the Boiling Water Reactor (BWR). Historically the BWR concept was developed after the PWR concept. Today 80% of light water reactors operating in the world are of PWR-type. This comparison is comprehensive and detailed. First the main technical features are reviewed and compared: reactor architecture, core and fuel design, reactivity control, reactor vessel, cooling systems and reactor containment. Secondly, various aspects concerning reactor operations like reactor control, fuel management, maintenance, inspections, radiation protection, waste generation and reactor reliability are presented and compared for both reactors. As for the issue of safety, it is highlighted that the accidental situations are too different for the 2 reactors to be compared. The main features of reactor safety are explained for both reactors

  10. Effect of water chemistry on deposition for PWR plant operation

    International Nuclear Information System (INIS)

    Le Calvar, Marc; Bretelle, J. L.; Cailleaux, J. P.; Lacroix, R.; Guivarch, M.; Gay, N.; Taunier, S.; Gressier, F.; Varry, P.; Corredera, G.; Alos-Ramos, O.; Dijoux, M.

    2012-09-01

    For Pressurized Water Reactor (PWR) operation, water chemistry guidelines, specifications and associated surveillance programs are key to avoid deposition of oxides. Deposition of oxides can be detrimental by disrupting results of flow measurements, decreasing the thermal exchange capacity, or even by impairing safety. This paper describes the most important cases of deposition, their consequences for operation, and the implemented improvements to avoid their reoccurrence. Deposition that led to a Crud Induced Power Shift (CIPS) is also described. In the primary and in the secondary sides, orifice plates are typically used for measuring feedwater flow rate in nuclear power plants. Feedwater flow rates are used for control purposes and are important safety parameters as they are used to determine the plant's operating power level. Fouling of orifice plates in the primary side has been found during surveillance testing. For reactor coolant pumps, the formation of deposits on the seal No.1 can cause abnormally high or low leak rates through the seal. The leak rate through this seal must be carefully maintained within a prescribed range during plant operation. In the secondary side, orifice plate fouling has been the cause of feedwater flow/reference thermal power drift. For the steam generators (SG), magnetite deposition has led to fouling of the tube bundle, clogging of the quadri-foiled support plate holes and hard sludge formation on the base plate. For the generators, copper hollow conductors are widely used. Buildup of copper oxides on the interior walls of copper conductors has caused insufficient heat transfer. All these deposition cases have received adequate attention, understanding and response via improvement of our surveillance programs. (authors)

  11. Laser based maintenance technology for PWR power plants

    International Nuclear Information System (INIS)

    Itaru Chida; Masaki Yoda; Naruhiko Mukai; Yuji Sano; Makoto Ochiai; Takahiro Miura; Ryoichi Saeki

    2005-01-01

    Stress corrosion cracking (SCC) is the major factor to reduce the reliability of aged reactor components. Toshiba has developed various laser-based maintenance technologies and already applied them to several existing nuclear power plants. Recently, we have developed the maintenance system for the inner surface of bottom-mounted instruments (BMI) of PWR plants. This system performs nondestructive testing (NDT) and preventive maintenance against SCC by using YAG lasers. Laser ultrasonic testing (LUT) has a great potential to be applied to the remote inspection of reactor components. Laser-induced surface acoustic wave (SAW) inspection system was developed by using a compact probe with a multi-mode optical fiber and an interferometer. This system is used for both detection and depth measurement of surface-breaking cracks. It is confirmed through laboratory studies that the developed system successfully detected and sized micro slits of around 1.0 mm depth on weld metal and heat-affected zone (HAZ). SCCs produced by chemical method were also tested by the system. For the preventive maintenance treatment, laser-peening (LP) technology was developed and already applied to several reactor components in operating BWR plants. LP is a novel process to improve residual stress from tensile to compressive on material surface layer by irradiating focused high-power laser pulses in water. We have developed a fiber-delivered LP (FLP) system as a preventive maintenance against SCC. For checking the effect of FLP, we carried out FLP experiments on the inner surface of a small tube-shaped Alloy 600 by using this system. After FLP, residual stress was measured by X-ray method for radial and axial directions on the inner surface of the tube, and effectiveness of stress improvement was proved. Based on these experiences, LUT and FLP were applied to Ikata unit-1 of Shikoku Electric Power Company Inc. and successfully treated the inner surface of BMIs. (authors)

  12. Radiation detectors for the control of PWR nuclear boilers

    International Nuclear Information System (INIS)

    Duchene, J.

    1977-01-01

    The neutronic control in French PWR is effected by: 2 channels of measurement of intermediate power using γ'-compensated boron-coated ionization chambers 4 channels of measurement of high power with 'long' boron chambers also used in axial off-set measurement. A movable in-core measuring system is used for the fuel management and the power distribution monitoring. The instrumentation of start-up and intermediate power is conventional; the chambers of the axial off-set measurement and the in-core system are special for this type of power plant, they are discussed in details. The essential properties of the various types of detector, their major advantages or drawbacks, their comparative adaptation to the functions to be performed in the plant are summarized in a table. The 'long chambers' (on use in Fessenheim I and II, and soon in Bugey II) are boron coated current ionization chambers, without γ compensation, intended for power measurement. In-core measurements first involved activation methods - movable wires giving flux profiles, -or activable nuts (the Aeroball System at Trino Vercellese, Chooz...). In on-line neutron detectors, used at fixed positions, the electric signal is generated from: ionization the gas filling fission ionization chambers and γ ionization chambers; direct collection of the charged particles emitted from the convertor element in self-powered neutron detectors (rhodium, silver or vanadium) or self-powered γ detectors (cobalt); or thermoelectric effect in neutron and γ thermometers. The in-core measurement unit developped by Framatome is a movable miniaturized fission chamber system (at Tihange), every French exported power plant being now equipped with it [fr

  13. Draining water loop seals in a PWR plant

    International Nuclear Information System (INIS)

    Bhavnani, D.; Flaherty, J.; Coward, B.; Gorga, J.

    1994-01-01

    Pressurized Water Reactor (PWR) power plants include safety valves (SVs) on the pressurizer to provide over-pressure protection for the primary coolant system. In addition, power operated relief valves (PORV) are also included to allow pressure control. These valves are located in piping connecting the pressurizer to the pressurizer relief tank (PRT). In some plants, the SV inlet piping is oriented to specifically form a water loop seal adjacent to the valves. Steam from the pressurizer enters the piping and condenses to form a water seal against the valve. The water seal provides protection for the valve's internals and creates a better valve seal. Additionally, the PORV inlet piping may also be oriented to form a water loop seal similar to that for SVs. The SVs and PORVs are normally closed. During an over-pressure transient, the valves open and the water seals discharge through the valves and downstream piping to the PRT. This sudden discharge of the water slug through piping normally containing low pressure steam or air can cause significant unbalanced hydrodynamic forces on the piping and cause piping or pipe support damage. Utilities must demonstrate that these forces will not cause sufficient damage such that the piping will no longer function as designed. This paper describes a method for reducing these unbalanced forces by installing drains that allow the condensed loop seal water to flow back into the pressurizer. This approach, which is a passive modification in which no active components are added, reduces the mass of water available for acceleration through the valve and piping, significantly decreasing the hydrodynamic forces. Another important consideration is that the modification has little or no effect on plant operation and maintenance. Thermal hydraulic analyses are performed to estimate the hydrodynamic forces and time history finite element stress analyses are performed to calculate pipe stress and pipe support loads

  14. An EPRI perspective and overview of PWR primary chemistry optimization

    International Nuclear Information System (INIS)

    Perkins, David; Haas, Carey; Kucuk, Aylin; Reid, Rick

    2009-01-01

    Initiatives are underway to optimize primary water chemistry to promote long term equipment reliability, dose and fuel deposit management, and maintenance of system and core integrity. These initiatives include increased primary system pH(t), zinc injection, and optimization of primary system hydrogen concentration. The concurrent demands of higher core power densities and longer operating cycles make implementation and evaluation of such chemistry changes increasingly challenging to plant chemists and operators. One of the most significant changes has been the injection of zinc. The primary reason for zinc injection is dose reduction as part of an overall dose management program. Since initial implementation in 1994, zinc injection has been successfully initiated at more than 60 Pressurized Water Reactors (PWRs) worldwide. This equates to approximately 23% of the operating PWR's. Current projections show that greater than 25% of the fleet will be injecting zinc by the end of 2010. The EPRI Materials Reliability Program (MRP), Fuel Reliability Program (FRP) and Chemistry program have ongoing research related to zinc injection and elevated hydrogen to support industry efforts in dose reduction, mitigation of PWSCC in nickel-based alloys and improved fuel reliability. Fuel performance, effects on plant materials and safety implications must be considered prior to modification of primary system chemistry controls. Evaluation of these effects typically requires additional research, which may include fuel performance monitoring and post-shutdown fuel surveillances to understand and evaluate the impact of changes on system and fuel performance. The poster describes ongoing industry experience(s) and research work in the EPRI Chemistry, FRP, and MRP areas related to ongoing primary chemistry programmatic changes. (author)

  15. Analyses of PWR boron dilution consequences with the Arrotta code

    International Nuclear Information System (INIS)

    Johanson, E.; Cheng, H.W.; Sehgal, B.R.

    1998-03-01

    During the past few years, major attention has been paid to analyzing the issue of reactivity initiated accidents (RIAs), of which the boron dilution event is of very special interest to the countries having pressurized water reactors (PWRs) in their nuclear power delivery systems. The scenario considered is that if an inadvertent accumulation of boron free water in one loop during reactor startup operations of a PWR and the inadvertent startup of the reactor coolant pump (RCP) in the loop. This could then lead to a rapid boron dilution in the core, which can in turn give rise to a power excursion. This report is devoted to studying the potential physical and thermal hydraulic consequences of a slug of diluted coolant entering the core after one RCP start under a couple of postulated cases. The severity of the consequences of such a scenario is primarily determined by the amount of positive reactivity insertion, and they are also related to the reactivity insertion rate. Therefore, in the report, detailed calculations and analyses have been carried out from case to case by using the well-known space-time kinetics code, ARROTTA. As a result, the spatial distribution for nodal power, fuel enthalpy, fuel temperature and clad outside temperature as well as the change in core reactivity, total core power and peak fuel temperature can be provided. In general, the maximum fuel enthalpy, peak fuel temperature, and clad outside temperature, for all the cases considered in the report, do not exceed their respective routine safety limitations because of the strong Doppler effect and moderator temperature feedback, except if the safety limitations on fuel enthalpy addition for high burnup fuel are drastically reduced

  16. The reliability data acquisition system in PWR nuclear power plants

    International Nuclear Information System (INIS)

    Lienart, P.

    1984-01-01

    In April 1978, Electricite de France put a reliability data acquisition system (SRDF) into operation at its two nuclear power plant sites: Fessenheim and Bugey. In the light of the experience acquired and the advantages offered by such a data bank, this system has been progressively extended since 1982 to cover the entire PWR network. The SRDF was originally designed for the follow-up of 4000 items of equipment per pair of units. However, the various difficulties encountered in gathering data made it necessary - in order to safeguard the quality of the information - to reduce this number initially to 800 major mechanical or electromechanical items of equipment designed to ensure the safety or availability of the units. Subsequently, an increase to 1100 was possible. The SRDF consists of a centralized information bank linked by telephone to the various nuclear sites. The software enables the data-acquisition cards to be introduced, modified or deleted. Any user can gain access to the bank by simply making queries in real time. The quality of the acquisition and processing of the data depend on a list of equipment confined to essential operational systems and on a card design combining, as far as possible, the precision and accessibility of the data. A method of logical failure analysis has also been devised, its main purposes being to provide the following: (1) aid to card instruction; (2) an easier way of checking the uniformity of information concerning a failure; and (3) compatibility between the instructions and analysis of data, thereby facilitating development of the data-processing program. (author)

  17. A PWR reactor downcomer modification for reduction of ECC bypass flow during LOCA

    International Nuclear Information System (INIS)

    Popov, N.; Bosevski, T.

    1986-01-01

    The ECC bypass phenomenon in the PWR reactor down-comer, which delays the reactor vessel refilling, after cold leg large break LOCA accident, has been subject of analysis in this paper. In the paper, a particular construction modification of the reactor down-comer has been suggested by inserting vertical ribs, aimed to intensify the reactor ECC refilling following the LOCA accident, and to advance the thermal-hydraulics safety of post-accidental cooling of the PWR reactors. To verify the effectiveness of the suggested down-comer construction modification, some properly selected results, obtained by corresponding verified mathematical model, have been presented in this paper. (author)

  18. Contribution to the study of the conversion PWR type reactors to the thorium cycle

    International Nuclear Information System (INIS)

    Martins Filho, J.R.

    1980-01-01

    The use of the thorium cycle in PWR reactors is discussed. The fuel has been calculated in the equilibrium condition for a economic comparison with the uranium cycle (in the same condition). First of all, a code named EQUILIBRIO has been developed for the fuel equilibrium calculation. The results gotten by this code, were introduced in the LEOPARD code for the fuel depletion calculation (in the equilibrium cycle). Same important physics details of fuel depletion are studied, for instance: the neutron balance, power sharing, fuel burnup, etc. The calculations have been done taking as reference the Angra-1 PWR reactor. (Author) [pt

  19. Scope and procedures of fuel management for PWR nuclear power plant

    International Nuclear Information System (INIS)

    Yao Zenghua

    1997-01-01

    The fuel management scope of PWR nuclear power plant includes nuclear fuel purchase and spent fuel disposal, ex-core fuel management, in-core fuel management, core management and fuel assembly behavior follow up. A suit of complete and efficient fuel management procedures have to be created to ensure the quality and efficiency of fuel management work. The hierarchy of fuel management procedure is divided into four levels: main procedure, administration procedure, implement procedure and technic procedure. A brief introduction to the fuel management scope and procedures of PWR nuclear power plant are given

  20. Neutronic feasibility of PWR core with mixed oxide fuels in the Republic of Korea

    International Nuclear Information System (INIS)

    Kim, Y.J.; Joo, H.K.; Jung, H.G.; Sohn, D.S.

    1997-01-01

    Neutronic feasibility of a PWR core with mixed oxide (MOX) fuels has been investigated as part of the feasibility study for recycling spent fuels in Korea. A typical 3-loop PWR with 900 MWe capacity is selected as reference plant to develop equilibrium core designs with low-leakage fuel management scheme, while incorporating various MOX loading. The fuel management analyses and limited safety analyses show that, safely stated, MOX recycling with 1/3 reload fraction can be accommodated for both annual and 18 month fuel cycle schemes in Korean PWRs, without major design modifications on the reactor systems. (author). 12 refs, 4 figs, 3 tabs

  1. Assessment of options for the treatment of Sizewell PWR liquid effluent

    International Nuclear Information System (INIS)

    Hornby, J.; Allam, J.; Knibbs, R.H.

    1992-01-01

    This report describes the origins of PWR liquid waste streams, their composition and rates of arising. Data has been collected from operational PWRs and estimates obtained for Sizewell B PWR liquid waste streams. Current liquid waste treatment practices are reviewed and assessments made of established and novel treatment techniques which could be applicable to Sizewell B. A short list of treatment options is given and recommendations are made relating to established treatment technologies suitable for Sizewell B and also to development work on more novel treatments which could lead to a reduction in waste disposal volumes. (author)

  2. Effect of TOC [total organic carbon] on a PWR secondary cooling water system

    International Nuclear Information System (INIS)

    Gau, J.Y.; Oung, J.C.; Wang, T.Y.

    1989-01-01

    Increasing the amount of total organic carbon (TOC) during the wet layup of the steam generator was a problem in PWR nuclear power plant in Taiwan. The results of surveys of TOC in PWR secondary cooling water systems had shown that the impurity of hydrazine and the bacteria were the main reasons that increase TOC. These do not have a corrosion effect on Inconel 600 and carbon steel when the secondary cooling water containing the TOC is below 200 ppb. But the anaerobic bacteria from the steam generator in wet layup will increase corrosion rate of carbon steel and crevice corrosion of Inconel 600. (author)

  3. Operating experience with an on-line vibration control system for PWR main coolant pumps

    International Nuclear Information System (INIS)

    Runkel, J.; Stegemann, D.; Vortriede, A.

    1996-01-01

    The main circulation pumps are key components of nuclear power plants with pressurized water reactors, because the availability of the main circulation pumps has a direct influence on the availability and electrical output of the entire plant. The on-line automatic vibration control system ASMAS was developed for early failure detection during the normal operation of the main circulation pumps in order to avoid unexpected outages and to establish the possibility of preventive maintenance of the pumps. This system is permanently and successfully operating in three German 1300 MW el NPP's with PWR and has been successfully tested in a 350 MW el NPP with a PWR. (orig.)

  4. Operating experience with an on-line vibration control system for PWR main coolant pumps

    International Nuclear Information System (INIS)

    Runkel, J.; Stegemann, D.; Vortriede, A.

    1998-01-01

    The main circulation pumps are key components of nuclear power plants with pressurized water reactors (PWRs), because the availability of the main circulation pumps has a direct influence on the availability and electrical output of the entire plant. The on-line automatic vibration control system ASMAS was developed for early failure detection during the normal operation of the main circulation pumps in order to avoid unexpected outages and to establish the possibility of preventive maintenance of the pumps. This system is permanently and successfully operating in three German 1300 MW e1 NPP's with PWR and has been successfully tested in a 350 MW e1 NPP with a PWR. (orig.)

  5. On-line analysis of ETA and organic acids in secondary systems of PWR plants

    International Nuclear Information System (INIS)

    Kurashina, Masahiko; Uzawa, Hideo; Utagawa, Koya; Takaku, Hiroshi

    2005-01-01

    To reduce the iron concentration in the secondary water of plants with pressurized water reactors (PWRs), ethanolamine (ETA) is used as an alkalizing agent in the secondary cycle. An on-line ion chromatography (IC) monitoring system for monitoring concentrations of ETA and anions of organic acids was developed, its performance was evaluated, and verification tests were conducted at an actual PWR plant. It was demonstrated that the concentration of both ETA and anions of organic acids may be successfully monitored by IC in PWR secondary cycle streams alkalized by ETA. (orig.)

  6. Prevention and mitigation of steam-generator water-hammer events in PWR plants

    International Nuclear Information System (INIS)

    Han, J.T.; Anderson, N.

    1982-11-01

    Water hammer in nuclear power plants is an unresolved safety issue under study at the NRC (USI A-1). One of the identified safety concerns is steam generator water hammer (SGWH) in pressurized-water reactor (PWR) plants. This report presents a summary of: (1) the causes of SGWH; (2) various fixes employed to prevent or mitigate SGWH; and (3) the nature and status of modifications that have been made at each operating PWR plant. The NRC staff considers that the issue of SGWH in top feedring designs has been technically resolved. This report does not address technical findings relevant to water hammer in preheat type steam generators. 10 figures, 2 tables

  7. Experiments on natural circulation during PWR severe accidents and their analysis

    International Nuclear Information System (INIS)

    Sehgal, B.R.; Stewart, W.A.; Sha, W.T.

    1988-01-01

    Buoyancy-induced natural circulation flows will occur during the early-part of PWR high pressure accident scenarios. These flows affect several key parameters; in particular, the course of such accidents will most probably change due to local failures occurring in the primary coolant system (CS) before substantial core degradation. Natural circulation flow patterns were measured in a one-seventh scale PWR PCS facility at Westinghouse RandD laboratories. The measured flow and temperature distributions are report in this paper. The experiments were analyzed with the COMMIX code and good agreement was obtained between data and calculations. 10 refs., 8 figs., 2 tabs

  8. Nonlinear Fuzzy Model Predictive Control for a PWR Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Xiangjie Liu

    2014-01-01

    Full Text Available Reliable power and temperature control in pressurized water reactor (PWR nuclear power plant is necessary to guarantee high efficiency and plant safety. Since the nuclear plants are quite nonlinear, the paper presents nonlinear fuzzy model predictive control (MPC, by incorporating the realistic constraints, to realize the plant optimization. T-S fuzzy modeling on nuclear power plant is utilized to approximate the nonlinear plant, based on which the nonlinear MPC controller is devised via parallel distributed compensation (PDC scheme in order to solve the nonlinear constraint optimization problem. Improved performance compared to the traditional PID controller for a TMI-type PWR is obtained in the simulation.

  9. AREVA solutions to licensing challenges in PWR and BWR reload and safety analysis

    Energy Technology Data Exchange (ETDEWEB)

    Curca-Tivig, Florin [AREVA GmbH, Erlangen (Germany)

    2016-05-15

    Regulatory requirements for reload and safety analyses are evolving: new safety criteria, request for enlarged qualification databases, statistical applications, uncertainty propagation.. In order to address these challenges and access more predictable licensing processes, AVERA is implementing consistent code and methodology suites for PWR and BWR core design and safety analysis, based on first principles modeling and extremely broad verification and validation data base. Thanks to the high computational power increase in the last decades methods' development and application now include new capabilities. An overview of the main AREVA codes and methods developments is given covering PWR and BWR applications in different licensing environments.

  10. Analysis of the alternatives for the chemical treatment of the secondary circuit of PWR power plants

    International Nuclear Information System (INIS)

    Lopes, J.P.G.; Silva Neto, A.J. da; Braganca Junior, A.; Dominguez, D.

    1990-01-01

    The operational experiences within PWR power plants shows that the major problems which affect the plant availability occurs in the secondary side, mainly in the steam generators and condenser. The aim of this report is to perform an evaluation of the main chemical treatment processes, which are applied to the secondary side of PWR power plants in order to reduce the corrosion problems to which are exposed the system equipment, minimizing in this way the shut down and maintenance cost for repairs and replacement of damaged components. (author)

  11. Evaluation of PWR steam generator water hammer. Final technical report, June 1, 1976--December 31, 1976

    International Nuclear Information System (INIS)

    Block, J.A.; Crowley, C.J.; Rothe, P.H.; Wallis, G.B.; Young, L.R.

    1977-05-01

    An investigation of waterhammer in the main feedwater piping of PWR steam generators due to water slugs formed in the steam generator feedring is reported. The relevant evidence from PWR operation and testing is compiled and summarized. The state-of-the-art of analysis of related phenomena is reviewed. Original exploratory modeling experiments at 1 / 10 and 1 / 4 scale are reported. Bounding analyses of the behavior are performed and several key phenomena have been identified for the first time. Recommendations to the Nuclear Regulatory Commission are made

  12. Applicability of 3D Monte Carlo simulations for local values calculations in a PWR core

    Science.gov (United States)

    Bernard, Franck; Cochet, Bertrand; Jinaphanh, Alexis; Jacquet, Olivier

    2014-06-01

    As technical support of the French Nuclear Safety Authority, IRSN has been developing the MORET Monte Carlo code for many years in the framework of criticality safety assessment and is now working to extend its application to reactor physics. For that purpose, beside the validation for criticality safety (more than 2000 benchmarks from the ICSBEP Handbook have been modeled and analyzed), a complementary validation phase for reactor physics has been started, with benchmarks from IRPHEP Handbook and others. In particular, to evaluate the applicability of MORET and other Monte Carlo codes for local flux or power density calculations in large power reactors, it has been decided to contribute to the "Monte Carlo Performance Benchmark" (hosted by OECD/NEA). The aim of this benchmark is to monitor, in forthcoming decades, the performance progress of detailed Monte Carlo full core calculations. More precisely, it measures their advancement towards achieving high statistical accuracy in reasonable computation time for local power at fuel pellet level. A full PWR reactor core is modeled to compute local power densities for more than 6 million fuel regions. This paper presents results obtained at IRSN for this benchmark with MORET and comparisons with MCNP. The number of fuel elements is so large that source convergence as well as statistical convergence issues could cause large errors in local tallies, especially in peripheral zones. Various sampling or tracking methods have been implemented in MORET, and their operational effects on such a complex case have been studied. Beyond convergence issues, to compute local values in so many fuel regions could cause prohibitive slowing down of neutron tracking. To avoid this, energy grid unification and tallies preparation before tracking have been implemented, tested and proved to be successful. In this particular case, IRSN obtained promising results with MORET compared to MCNP, in terms of local power densities, standard

  13. PWR core and spent fuel pool analysis using scale and nestle

    International Nuclear Information System (INIS)

    Murphy, J. E.; Maldonado, G. I.; St Clair, R.; Orr, D.

    2012-01-01

    The SCALE nuclear analysis code system [SCALE, 2011], developed and maintained at Oak Ridge National Laboratory (ORNL) is widely recognized as high quality software for analyzing nuclear systems. The SCALE code system is composed of several validated computer codes and methods with standard control sequences, such as the TRITON/NEWT lattice physics sequence, which supplies dependable and accurate analyses for industry, regulators, and academia. Although TRITON generates energy-collapsed and space-homogenized few group cross sections, SCALE does not include a full-core nodal neutron diffusion simulation module within. However, in the past few years, the open-source NESTLE core simulator [NESTLE, 2003], originally developed at North Carolina State Univ. (NCSU), has been updated and upgraded via collaboration between ORNL and the Univ. of Tennessee (UT), so it now has a growingly seamless coupling to the TRITON/NEWT lattice physics [Galloway, 2010]. This study presents the methodology used to couple lattice physics data between TRITON and NESTLE in order to perform a three-dimensional full-core analysis employing a 'real-life' Duke Energy PWR as the test bed. The focus for this step was to compare the key parameters of core reactivity and radial power distribution versus plant data. Following the core analysis, following a three cycle burn, a spent fuel pool analysis was done using information generated from NESTLE for the discharged bundles and was compared to Duke Energy spent fuel pool models. The KENO control module from SCALE was employed for this latter stage of the project. (authors)

  14. PWR core and spent fuel pool analysis using scale and nestle

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J. E.; Maldonado, G. I. [Dept. of Nuclear Engineering, Univ. of Tennessee, Knoxville, TN 37996-2300 (United States); St Clair, R.; Orr, D. [Duke Energy, 526 S. Church St, Charlotte, NC 28202 (United States)

    2012-07-01

    The SCALE nuclear analysis code system [SCALE, 2011], developed and maintained at Oak Ridge National Laboratory (ORNL) is widely recognized as high quality software for analyzing nuclear systems. The SCALE code system is composed of several validated computer codes and methods with standard control sequences, such as the TRITON/NEWT lattice physics sequence, which supplies dependable and accurate analyses for industry, regulators, and academia. Although TRITON generates energy-collapsed and space-homogenized few group cross sections, SCALE does not include a full-core nodal neutron diffusion simulation module within. However, in the past few years, the open-source NESTLE core simulator [NESTLE, 2003], originally developed at North Carolina State Univ. (NCSU), has been updated and upgraded via collaboration between ORNL and the Univ. of Tennessee (UT), so it now has a growingly seamless coupling to the TRITON/NEWT lattice physics [Galloway, 2010]. This study presents the methodology used to couple lattice physics data between TRITON and NESTLE in order to perform a three-dimensional full-core analysis employing a 'real-life' Duke Energy PWR as the test bed. The focus for this step was to compare the key parameters of core reactivity and radial power distribution versus plant data. Following the core analysis, following a three cycle burn, a spent fuel pool analysis was done using information generated from NESTLE for the discharged bundles and was compared to Duke Energy spent fuel pool models. The KENO control module from SCALE was employed for this latter stage of the project. (authors)

  15. Study of PWR reactor efficiency as a function of turbine steam extractions; Estudo da otimizacao da eficiencia de reator PWR em funcao das extracoes de vapor da turbina

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Janine Gandolpho da; Alvim, Antonio Carlos Marques; Martinez, Aquilino Senra [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2002-07-01

    The objective of this work is to optimize the extractions of the low-pressure turbine of a PWR nuclear reactor, in order to obtain the best thermodynamic cycle efficiency. We have analyzed typical data of a 1300 MW PWR reactor, operating at 25%, 50%, 75% and 100% capacities, respectively. The first stage of this study consists of generating a mathematical model capable of describing the reactor behavior and efficiency at any power level. The second stage of this study consists of to combine the generated mathematical model in an optimization computer program that optimize the extractions flow of the low-pressure turbine until it finds the optimal system efficiency. This work does not alter the nuclear facility project in any way. (author)

  16. PWR Secondary Water Chemistry Control Status: A Summary of Industry Initiatives, Experience and Trends Relative to the EPRI PWR Secondary Water Chemistry Guidelines

    International Nuclear Information System (INIS)

    Fruzzetti, Keith; Choi, Samuel

    2012-09-01

    The latest revision of the EPRI Pressurized Water Reactor (PWR) Secondary Water Chemistry Guidelines was issued in February 2009. The Guidelines continue to focus on minimizing stress corrosion cracking (SCC) of steam generator tubes, as well as minimizing degradation of other major components / subsystems of the secondary system. The Guidelines provide a technically-based framework for a plant-specific and effective PWR secondary water chemistry program. With the issuance of Revision 7 of the Guidelines in 2009, many plants have implemented changes that allow greater flexibility on startup. For example, the previous Guidelines (Revision 6) contained a possible low power hold at 5% power and a possible mid power hold at approximately 30% power based on chemistry constraints. Revision 7 has established a range over which a plant-specific value can be chosen for the possible low power hold (between 5% and 15%) and mid power hold (between 30% and 50%). This has provided plants the ability to establish significant plant evolutions prior to reaching the possible power hold; such as establishing seal steam to the condenser, placing feed pumps in service, or initiating forward flow of heater drains. The application of this flexibility in the industry will be explored. This paper also highlights the major initiatives and industry trends with respect to PWR secondary chemistry; and outlines the recent work to effectively address them. These will be presented in light of recent operating experience, as derived from EPRI's PWR Chemistry Monitoring and Assessment (CMA) program (which contains more than 400 cycles of operating chemistry data). (authors)

  17. PWR water chemistry controls: a perspective on industry initiatives and trends relative to operating experience and the EPRI PWR water chemistry guidelines

    International Nuclear Information System (INIS)

    Fruzzetti, K.; Choi, S.; Haas, C.; Pender, M.; Perkins, D.

    2010-01-01

    An effective PWR water chemistry control program must address the following goals: Minimize materials degradation (e.g., PWSCC, corrosion of fuel, corrosion damage of steam generator (SG) tubes); Maintain fuel integrity and good performance; Minimize corrosion product transport (e.g., transport and deposition on the fuel, transport into the SGs where it can foul tube surfaces and create crevice environments for the concentration of corrosive impurities); Minimize dose rates. Water chemistry control must be optimized to provide overall improvement considering the sometimes variant constraints of the goals listed above. New technologies are developed for continued mitigation of materials degradation, continued fuel integrity and good performance, continued reduction of corrosion product transport, and continued minimization of plant dose rates. The EPRI chemistry program, in coordination with other EPRI programs, strives to improve these areas through application of chemistry initiatives, focusing on these goals. This paper highlights the major initiatives and issues with respect to PWR primary and secondary system chemistry and outlines the recent, on-going, and proposed work to effectively address them. These initiatives are presented in light of recent operating experience, as derived from EPRI's PWR chemistry monitoring and assessment program, and EPRI's water chemistry guidelines. (author)

  18. Issues and possible solutions of nuclear power standard system in china

    International Nuclear Information System (INIS)

    Li Xiaoyan; Pu Jilong

    2008-01-01

    The construction of nuclear power standard system shall follow the development state of the nuclear power in China, and shall be taken as one of the important support for the self-reliance in the development of nuclear industry. However, there is no national nuclear power standard systems that is matched to the industrial system and technology base in China. It is widely recognized in nuclear industry that the nuclear power standard system must be established. This paper discusses various problems of the current national nuclear power standard system and suggests the possible solutions. Electricity industry standard system can be referenced to set up nuclear power standard system in China. Considering the need to construct a lot of PWR nuclear power stations in China, the design and construction standard system for PWR NPP shall be established. The nuclear safety guides in China shall be incorporated into the nuclear power standards. (authors)

  19. Colloids in PWR primary and secondary coolant. Innovative analytical methods

    International Nuclear Information System (INIS)

    Nowotka, Karsten; Guillodo, Michael; Burchardt, Carsten; Geier, Roland; Lehr, Robert; Stellwag, Bernhard

    2014-01-01

    Transport and deposition of corrosion products in the colloid size range between 1 nm and 1 μm are important for heat transfer performance and corrosion in primary and secondary cooling circuits of LWRs. Direct analysis of the properties of small-sized colloids (< 0.45 μm) is difficult due to the pronounced change of the physicochemical properties of coolant samples in sampling lines. An innovative method, based on a filter cascade and developed in the AREVA Technical Center, named 'Colloid Catcher' (CC, patent pending), permits on-line measurements of the properties of corrosion products in the coolant of LWRs. CC measurements are complementary to classic trace analysis addressing the soluble content. Low and high temperature (up to 330°C) test sections are available, depending on our customer's needs. The CC contains differential pressure detectors at each of the three consecutive membrane filters which allow for an in-situ characterization without modification of the corrosion products chemical nature due to temperature changes and subsequent exposure to the atmosphere. With this method, a 'Colloid Fingerprint' of the test solution can be obtained, ideal for an assessment of the transport and deposition of corrosion products in laboratory and on-site studies. The on-line data can of course be complemented by post filtration membrane characterization by digestion and/or optical methods. The high temperature CC serves at the same time as a sampling point for grab samples, with good reproducibility thanks to continuous liquid flow. The CC has been designed to be deployable on laboratory or industrial cooling circuits. The CC test sections have been qualified using AREVA Technical Center's test loops. First test results obtained with the LT CC are presented. Laboratory data can be used to back up existing results and data of on-site measurement campaigns at BWR and PWR plants which were determined with a basic version of the LT CC

  20. Assessment of TRAC-PF1/MOD1 code for large break LOCA in PWR

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Ohnuki, Akira; Murao, Yoshio; Abe, Yutaka.

    1993-03-01

    As the first step of the REFLA/TRAC code development, the TRAC/PF1/MOD1 code has been assessed for various experiments that simulate postulated large-break loss-of-coolant accident (LBLOCA) in PWR to understand the predictive capability and to identify the problem areas of the code. The assessment calculations were performed for separate effect tests for critical flow, counter current flow, condensation at cold leg and reflood as well as integral tests to understand predictability for individual phenomena. This report summarizes results from the assessment calculations of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The assessment calculations made clear the predictive capability and problem areas of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The areas, listed below, should be improved for more realistic and effective simulation of LBLOCA in PWR: (1) core heat transfer model during blowdown, (2) ECC bypass model at downcomer during refill, (3) condensation model during accumulator injection, and (4) core thermal hydraulic model during reflood. (author) 57 refs

  1. Criticality safety and sensitivity analyses of PWR spent nuclear fuel repository facilities

    NARCIS (Netherlands)

    Maucec, M; Glumac, B

    Monte Carlo criticality safety and sensitivity calculations of pressurized water reactor (PWR) spent nuclear fuel repository facilities for the Slovenian nuclear power plant Krsko are presented. The MCNP4C code was deployed to model and assess the neutron multiplication parameters of pool-based

  2. Radionuclide release from PWR spent fuel specimens with induced cladding defects

    International Nuclear Information System (INIS)

    Wilson, C.N.; Oversby, V.M.

    1984-03-01

    Radionuclide releases from pressurized water reactor (PWR) spent fuel rod specimens containing various artificially induced cladding defects were compared by leach testing. The study was conducted in support of the Nevada Nuclear Waste Storage Investigations (NNWSI) Waste Package Task to evaluate the effectiveness of failed cladding as a barrier to radionuclide release. Test description and results are presented. 6 references, 4 figures

  3. Development and application of integrated digital I and C system in Japanese PWR plants

    International Nuclear Information System (INIS)

    Tominaga, M.

    1995-01-01

    The Integrated Digital Instrumentation and Control (I and C) System has been developed and applied to non-safety grade I and C systems in the latest 5 Japanese PWR plants in 1990's. Based on the experience in these plants, the Integrated Digital I and C System will be planned to apply also to safety grade I and C systems in Advanced PWR (APWR) as the overall application of digital technology. The basic design task has been just started for APWR which is to be in commercial operation in early 2000's and under the development about various issues of safety grade digital I and C systems. On the other hand, in conventional Japanese PWR plants, digital I and C systems have been applied step by step since 1980's. For example, digital I and C systems for radio-active waste processing system have been adopted to 13 units, and dedicated digital I and C systems for Local loop control system to 8 units. The trend and status of development and application of the digital I and C systems, especially the Integrated Digital I and C System in Japanese PWR plants are presented. (5 refs., 4 figs.)

  4. Atmea launches Atmea1 the mid-sized generation 3+ PWR you can rely on

    International Nuclear Information System (INIS)

    2008-01-01

    ATMEA, a daughter company of AREVA NP and Mitsubishi Heavy Industries, is developing and will supply ATMEA1, the most advanced 1100 MWe PWR plant with the combination of the unique set of competence and experience of its parent companies. This folder presents the ATMEA1 reactor main features. (J.S.)

  5. Fuel assemblies for PWR type reactors: fuel rods, fuel plates. CEA work presentation

    International Nuclear Information System (INIS)

    Delafosse, Jacques.

    1976-01-01

    French work on PWR type reactors is reported: basic knowledge on Zr and its alloys and on uranium oxide; experience gained on other programs (fast neutron and heavy water reactors); zircaloy-2 or zircaloy-4 clad UO 2 fuel rods; fuel plates consisting of zircaloy-2 clad UO 2 squares of thickness varying between 2 and 4mm [fr

  6. Programme of hot points eradication (Co-60) led on French PWR type reactors

    International Nuclear Information System (INIS)

    Rocher, A.; Ridoux, P.; Anthoni, S.; Brun, C.

    1998-01-01

    The question of hot points (pellets rich in cobalt 59 or in cobalt 60 in a PWR type reactor), is studied from the radiation protection point of view. The purpose is to see how to optimize the radiation protection, the elimination of these hot points can bring an improvement. (N.C.)

  7. Simulation of fission products behavior in severe accidents for advanced passive PWR

    International Nuclear Information System (INIS)

    Tong, L.L.; Huang, G.F.; Cao, X.W.

    2015-01-01

    Highlights: • A fission product analysis model based on thermal hydraulic module is developed. • An assessment method for fission product release and transport is constructed. • Fission products behavior during three modes of containment response is investigated. • Source term results for the three modes of containment response are obtained. - Abstract: Fission product behavior for common Pressurized Water Reactor (PWR) has been studied for many years, and some analytical tools have developed. However, studies specifically on the behavior of fission products related to advanced passive PWR is scarce. In the current study, design characteristics of advanced passive PWR influencing fission product behavior are investigated. An integrated fission products analysis model based on a thermal hydraulic module is developed, and the assessment method for fission products release and transport for advanced passive PWR is constructed. Three modes of containment response are simulated, including intact containment, containment bypass and containment overpressure failure. Fission products release from the core and corium, fission products transport and deposition in the Reactor Coolant System (RCS), fission products transport and deposition in the containment considering fission products retention in the in-containment refueling water storage tank (IRWST) and in the secondary side of steam generators (SGs) are simulated. Source term results of intact containment, containment bypass and containment overpressure failure are obtained, which can be utilized to evaluate the radiological consequences

  8. Conception and construction rules for mechanical components of PWR nuclear island

    International Nuclear Information System (INIS)

    1988-06-01

    These rules of conception and construction for mechanical components of PWR nuclear island used in France are divided into 5 tomes bearing on: Tome 1: components of nuclear islands - Tome 2: materials - Tome 3: control methods - Tome 4: welding - Tome 5: fabrication [fr

  9. Reactor analysis support package (RASP). Volume 7. PWR set-point methodology. Final report

    International Nuclear Information System (INIS)

    Temple, S.M.; Robbins, T.R.

    1986-09-01

    This report provides an overview of the basis and methodology requirements for determining Pressurized Water Reactor (PWR) technical specifications related setpoints and focuses on development of the methodology for a reload core. Additionally, the report documents the implementation and typical methods of analysis used by PWR vendors during the 1970's to develop Protection System Trip Limits (or Limiting Safety System Settings) and Limiting Conditions for Operation. The descriptions of the typical setpoint methodologies are provided for Nuclear Steam Supply Systems as designed and supplied by Babcock and Wilcox, Combustion Engineering, and Westinghouse. The description of the methods of analysis includes the discussion of the computer codes used in the setpoint methodology. Next, the report addresses the treatment of calculational and measurement uncertainties based on the extent to which such information was available for each of the three types of PWR. Finally, the major features of the setpoint methodologies are compared, and the principal effects of each particular methodology on plant operation are summarized for each of the three types of PWR

  10. Achievement of a training simulator for PWR power plant: application to control parametric studies

    International Nuclear Information System (INIS)

    Salomon-Sigogne, A.

    1982-09-01

    A simulation tool adapted to training tasks is developed. One presents the description of the simulator. One studies the management of a model by NEPTUN X2. A general description of a 900 MW PWR power station and the modelling of the power station are presented. The results obtained on the FIDIANE version of the simulator are finally analyzed [fr

  11. Operating experience with PWR in the FRG (Federal Republic of Germany)

    International Nuclear Information System (INIS)

    Cramer, H.

    1980-01-01

    Operating experiences with PWR's in the Federal Republic of Germany has been exclusively with KWU turnkey power plants with U tube steam generators. Such experience started with the 345 MW Obrigheim plant in 1968 and includes the 670 MW Stade plant, the 1200/1300 MW Biblis plants, The 900 MW Neckarwestheim and the 1300 MW Unterweser plants. (E.G.) [pt

  12. A simulated test of physical starting and reactor physics on zero power facility of PWR

    International Nuclear Information System (INIS)

    Yao Zewu; Ji Huaxiang; Chen Zhicheng; Yao Zhiquan; Chen Chen; Li Yuwen

    1995-01-01

    The core neutron economics has been verified through experiments conducted at a zero power reactor with baffles of various thickness. A simulated test of physical starting of Qinshan PWR has been introduced. The feasibility and safety of the programme are verified. The research provides a valuable foundation for developing physical starting programme

  13. ''The place of the fatigue risks in the PWR maintenance programs''

    International Nuclear Information System (INIS)

    Dechelotte, J.; Bordes, P.; Pages, C.; Friedrich, J.M.

    2001-01-01

    The parts of components submitted to fatigue risk are more particularly controlled in operation. Three main cases are identified: the mechanical oligo-cyclic fatigue, the vibrating fatigue and the thermal fatigue. These cases are presented in this paper. As a precaution a complementary investigation program is implementing during the Number two decennial inspections of the 900 MW PWR. (A.L.B.)

  14. Depletion of gadolinium burnable poison in a PWR assembly with high burnup fuel

    Energy Technology Data Exchange (ETDEWEB)

    Refeat, Riham Mahmoud [Nuclear and Radiological Regulatory Authority (NRRA), Cairo (Egypt). Safety Engineering Dept.

    2015-12-15

    A tendency to increase the discharge burnup of nuclear fuel for Advanced Pressurized Water Reactors (PWR) has been a characteristic of its operation for many years. It will be able to burn at very high burnup of about 70 GWd/t with UO{sub 2} fuels. The U-235 enrichment must be higher than 5 %, which leads to the necessity of using an extremely efficient burnable poison like Gadolinium oxide. Using gadolinium isotope is significant due to its particular depletion behavior (''Onion-Skin'' effect). In this paper, the MCNPX2.7 code is used to calculate the important neutronic parameters of the next generation fuels of PWR. K-infinity, local peaking factor and fission rate distributions are calculated for a PWR assembly which burn at very high burnup reaching 70 GWd/t. The calculations are performed using the recently released evaluated Gadolinium cross section data. The results obtained are close to those of a LWR next generation fuel benchmark problem. This demonstrates that the calculation scheme used is able to accurately model a PWR assembly that operates at high burnup values.

  15. Fuel Cycle Cost Calculations for a 120,000 shp PWR for Ship Propulsion. RCN Report

    International Nuclear Information System (INIS)

    Dekker, N.H.; Foggi, C.; Giacomazzi, G.

    1972-02-01

    A parametric study of the fuel cycle costs for a 120,000 SHP PWR for ship propulsion has been carried out. Variable parameters are: fuel pellet diameter, moderating ratio and refuelling scheme. Minimum fuel cycle costs can be obtained at moderating ratios of about 2.2. Both fuel cycle costs and reactor control requirements favour the two batch core. (author)

  16. Method for measuring feedwater flow rate using ultrasonic technique in PWR power plant

    International Nuclear Information System (INIS)

    Ozaki, Yoshihiko; Oda, Minoru; Tanaka, Mitsuo

    1988-01-01

    At present, differential pressure type flowmeters are widely used in feedwater systems of PWR plants. In these flowmeters, however, scales gradually deposit at the nozzle throat during the plant operation, causing the apparent flow rate to increase and consequently becoming a serious problem for efficient plant operations. Therefore, a new type of ultrasonic flowmeter (USFM) having good stability and free of the above phenomenon has been developed. A method to compensate for the effect of dependency of sound velocity on water temperature and pressure corresponding to PWR feedwater conditions was contrived. The validity of the method was confirmed in an experiment for investigating the sound velocity dependency in practice. The performance of the USFM was also examined using a water loop in various flow conditions with satisfactory results. After the basic studies, finally, the USFM was tested in an actual PWR feedwater system for almost 3 yr. The USFM met all the required characteristics for PWR feedwater systems, those being linearity, accuracy and stability. (author)

  17. Rupther: a simulation approach applied to a PWR vessel failure during a severe accident

    International Nuclear Information System (INIS)

    Mongabure, Ph.; Nicolas, L.; Devos, J.

    2000-01-01

    The Rupther program (Rupture Under Thermal Conditions) is a part of the international researches on severe accidents in the PWR type reactors. The aim of the program is the definition of failure simulation validated by experimental data on vessel steel 16MND5 mechanical properties. The paper presents the program and the first results. (A.L.B.)

  18. PWR pressure vessel life management French approach for integrity assessment and maintenance strategy

    Energy Technology Data Exchange (ETDEWEB)

    Bezdikian, G. [Electricite de France (EDF), 93 - Saint-Denis (France); Moinereau, D. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Pichon, C.; Faidy, C.; Ternon-Morin, F. [Electricite de France (EDF), 69 - Villeurbanne (France). SEPTEN; Brillaud, C. [Electricite de France (EDF), 37 - Avoine (France)

    1998-07-01

    This conference deals with the studies carried out in France to justify of a PWR pressure vessel lifetime of at least 40 years. The results of the irradiation surveillance programs and of the fluences evaluation in the end of life are given as well as the EDF maintenance strategy. (O.M.)

  19. Response of pressurized water reactor (PWR) to network power generation demands

    International Nuclear Information System (INIS)

    Schreiner, L.A.

    1991-01-01

    The flexibility of the PWR type reactor in terms of response to the variations of the network power demands, is demonstrated. The factors that affect the transitory flexibility and some design prospects that allow the reactor fits the requirements of the network power demands, are also discussed. (M.J.A.)

  20. Performance analysis of canned motor pump and shaft seal pump at PWR

    International Nuclear Information System (INIS)

    Wang Benzhen; Wang Qingzhou; Xu Yangyang

    2014-01-01

    This article mainly introduced the development and structure of canned motor pump and shaft seal pump at PWR. Especialy, the performance of canned motor pump for AP1000 and shaft seal pump was analyed and compared, their advantages and shortcomings were pointed out, which provided reference for the relevant nuclear power technical staff. (authors)

  1. SIVAR - Computer code for simulation of fuel rod behavior in PWR during fast transients

    International Nuclear Information System (INIS)

    Dias, A.F.V.

    1980-10-01

    Fuel rod behavior during a stationary and a transitory operation, is studied. A computer code aiming at simulating PWR type rods, was developed; however, it can be adapted for simulating other type of rods. A finite difference method was used. (E.G.) [pt

  2. Concept of voltage monitoring for a nuclear power plant emergency power supply system (PWR 1300 MWe)

    International Nuclear Information System (INIS)

    Andrade, R.B. de

    1988-01-01

    Voltage monitoring concept for a Nuclear Power Plant Emergency Power Supply Systems (PWR 1300 MWe) is described based on the phylosophy adopted for Angra 2 and 3 NPP's. Some suggested setpoints are only guidance values and can be modified during plant commissioning for a better performance of the whole protection system. (author) [pt

  3. Neutron Collar Evolution and Fresh PWR Assembly Measurements with a New Fast Neutron Passive Collar

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Geist, William H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Root, Margaret A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rael, Carlos D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Belian, Anthony P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-02

    The passive neutron collar approach removes the effect of poison rods when using a 1mm Gd liner. This project sets out to solve the following challenges: BWR fuel assemblies have less mass and less neutron multiplication than PWR; and effective removal of cosmic ray spallation neutron bursts needed via QC tests.

  4. Assessment of void swelling in austenitic stainless steel PWR core internals.

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. M.; Energy Technology

    2006-01-31

    As many pressurized water reactors (PWRs) age and life extension of the aged plants is considered, void swelling behavior of austenitic stainless steel (SS) core internals has become the subject of increasing attention. In this report, the available database on void swelling and density change of austenitic SSs was critically reviewed. Irradiation conditions, test procedures, and microstructural characteristics were carefully examined, and key factors that are important to determine the relevance of the database to PWR conditions were evaluated. Most swelling data were obtained from steels irradiated in fast breeder reactors at temperatures >385 C and at dose rates that are orders of magnitude higher than PWR dose rates. Even for a given irradiation temperature and given steel, the integral effects of dose and dose rate on void swelling should not be separated. It is incorrect to extrapolate swelling data on the basis of 'progressive compounded multiplication' of separate effects of factors such as dose, dose rate, temperature, steel composition, and fabrication procedure. Therefore, the fast reactor data should not be extrapolated to determine credible void swelling behavior for PWR end-of-life (EOL) or life-extension conditions. Although the void swelling data extracted from fast reactor studies is extensive and conclusive, only limited amounts of swelling data and information have been obtained on microstructural characteristics from discharged PWR internals or steels irradiated at temperatures and at dose rates comparable to those of a PWR. Based on this relatively small amount of information, swelling in thin-walled tubes and baffle bolts in a PWR is not considered a concern. As additional data and relevant research becomes available, the newer results should be integrated with existing data, and the worthiness of this conclusion should continue to be scrutinized. PWR baffle reentrant corners are the most likely location to experience high swelling

  5. Assessment of void swelling in austenitic stainless steel PWR core internals

    International Nuclear Information System (INIS)

    Chung, H.M.

    2006-01-01

    As many pressurized water reactors (PWRs) age and life extension of the aged plants is considered, void swelling behavior of austenitic stainless steel (SS) core internals has become the subject of increasing attention. In this report, the available database on void swelling and density change of austenitic SSs was critically reviewed. Irradiation conditions, test procedures, and microstructural characteristics were carefully examined, and key factors that are important to determine the relevance of the database to PWR conditions were evaluated. Most swelling data were obtained from steels irradiated in fast breeder reactors at temperatures >385 C and at dose rates that are orders of magnitude higher than PWR dose rates. Even for a given irradiation temperature and given steel, the integral effects of dose and dose rate on void swelling should not be separated. It is incorrect to extrapolate swelling data on the basis of 'progressive compounded multiplication' of separate effects of factors such as dose, dose rate, temperature, steel composition, and fabrication procedure. Therefore, the fast reactor data should not be extrapolated to determine credible void swelling behavior for PWR end-of-life (EOL) or life-extension conditions. Although the void swelling data extracted from fast reactor studies is extensive and conclusive, only limited amounts of swelling data and information have been obtained on microstructural characteristics from discharged PWR internals or steels irradiated at temperatures and at dose rates comparable to those of a PWR. Based on this relatively small amount of information, swelling in thin-walled tubes and baffle bolts in a PWR is not considered a concern. As additional data and relevant research becomes available, the newer results should be integrated with existing data, and the worthiness of this conclusion should continue to be scrutinized. PWR baffle reentrant corners are the most likely location to experience high swelling rates, and

  6. THALES, Thermohydraulic LOCA Analysis of BWR and PWR

    International Nuclear Information System (INIS)

    ABE, Kiyoharu

    1990-01-01

    reactor coolant system, combustible gas burning, atmosphere- structure heat transfer, ventilation, containment spray cooling, etc. After the molten core penetrates the reactor bottom head, steam generation, concrete disintegration and noncondensable gas generation are calculated in the reactor cavity or the pedestal. 2 - Method of solution: Each of the THALES member codes first establishes the steady state conditions after reading input data. Then iterative time-dependent calculation is continued, taking account of various phenomena and events and their interactions which will occur in the course of a postulated severe accident. The transient calculations are iterated by the physical times specified by input. Generally the RCS thermal hydraulic analysis with the THALES-PM or THALES-BM code is first carried out and its results are transferred to the following containment analysis with the THALES-CV code. Then both results are transferred to a code for analyzing fission product release and transport behavior. Automatic data transfer is possible in the case the JAERI's ART code is used for fission product behavior analysis. In overall thermal hydraulic analysis, a new method is adopted aiming at sufficiently accurate estimation of mixture levels in the reactor coolant system and the containment in a reasonable computer time. The heat transfer calculation in the core is carried out based on the backward method. 3 - Restrictions on the complexity of the problem: Restrictions relating to storage allocation are: (1) Maximum number of radial regions in the core : 10; (2) Maximum number of axial increments in the fuel rods : 50; (3) Maximum number of loops in the PWR primary system : 4; (4) Maximum number of volumes in the PWR primary system : 11; (5) Number of BWR recirculation loops: 2 (fixed); (6) Number of volumes in the BWR reactor coolant system : 7 (fixed); (7) Maximum number of compartments in the containment : 10. There is another restriction, which relates to time step

  7. THYDE-P, PWR LOCA Thermohydraulic Transient Analysis

    International Nuclear Information System (INIS)

    Asahi, Yoshiro

    2001-01-01

    1 - Description of problem or function: THYDE-P1 analyzes the behaviour of LWR plants in response to various disturbances, including the thermal hydraulic transient following a break of the primary coolant pipe system, generally referred to as a loss-of-coolant-accident (LOCA). LOCA can be considered as the most critical condition for testing the methods and models for plant dynamics, since thermal hydraulic conditions in the system change drastically during the transient. THYDE-P is capable of a complete LOCA calculation from start to complete reflooding of the core by subcooled water. The program performs steady-state adjustment, which is complete in the sense that the steady state obtained is a set of exact solutions of all the transient equations without time derivatives, not only for plant hydraulics but also for all the other phenomena in the simulation of a PWR plant. THYDE-P2 contains among others the following improvements over THYDE-P1: (1) not only the mass and momentum equations but also the energy equation are included in the non-linear implicit scheme; (2) the valve model is implemented; (3) the relaxation equation for void fraction is theoretically derived; (4) vectorized programming is implemented; (5) both EM (evaluation mode) and BE (best estimate) calculations are possible. THYDE-W is an improved version of THYDE-P2 and contains the following additional features: (a) analysis of multiple number of disjoint loops is possible; (b) a control system simulation model is included; (c) the trip model has been improved; (d) heavy water is allowed as coolant; (e) the effect of drift flux is accounted for in the steady state calculation; (f) boron transport is included; (g) to obtain steady state loop heat balance, the option of adjusting the enthalpy distribution is prepared included in addition to that of adjusting heat exchanger areas; (h) to obtain steady state pressure distribution, three other options are prepared in addition to the original ones

  8. Analysis of difficulties accounting and evaluating nuclear material of PWR fuel plant

    International Nuclear Information System (INIS)

    Zhang Min; Jue Ji; Liu Tianshu

    2013-01-01

    Background: Nuclear materials accountancy must be developed for nuclear facilities, which is required by regulatory in China. Currently, there are some unresolved problems for nuclear materials accountancy of bulk nuclear facilities. Purpose: The retention values and measurement errors are analyzed in nuclear materials accountancy of Power Water Reactor (PWR) fuel plant to meet the regulatory requirements. Methods: On the basis of nuclear material accounting and evaluation data of PWR fuel plant, a deep analysis research including ratio among random error variance, long-term systematic error variance, short-term systematic error variance and total error involving Material Unaccounted For (MUF) evaluation is developed by the retention value measure in equipment and pipeline. Results: In the equipment pipeline, the holdup estimation error and its total proportion are not more than 5% and 1.5%, respectively. And the holdup estimation can be regraded as a constant in the PWR nuclear material accountancy. Random error variance, long-term systematic error variance, short-term systematic error variance of overall measurement, and analytical and sampling methods are also obtained. A valuable reference is provided for nuclear material accountancy. Conclusion: In nuclear material accountancy, the retention value can be considered as a constant. The long-term systematic error is a main factor in all errors, especially in overall measurement error and sampling error: The long-term systematic errors of overall measurement and sampling are considered important in the PWR nuclear material accountancy. The proposals and measures are applied to the nuclear materials accountancy of PWR fuel plant, and the capacity of nuclear materials accountancy is improved. (authors)

  9. Crack growth rates of nickel alloy welds in a PWR environment.

    Energy Technology Data Exchange (ETDEWEB)

    Alexandreanu, B.; Chopra, O. K.; Shack, W. J.; Energy Technology

    2006-05-31

    In light water reactors (LWRs), vessel internal components made of nickel-base alloys are susceptible to environmentally assisted cracking. A better understanding of the causes and mechanisms of this cracking may permit less conservative estimates of damage accumulation and requirements on inspection intervals. A program is being conducted at Argonne National Laboratory to evaluate the resistance of Ni alloys and their welds to environmentally assisted cracking in simulated LWR coolant environments. This report presents crack growth rate (CGR) results for Alloy 182 shielded-metal-arc weld metal in a simulated pressurized water reactor (PWR) environment at 320 C. Crack growth tests were conducted on 1-T compact tension specimens with different weld orientations from both double-J and deep-groove welds. The results indicate little or no environmental enhancement of fatigue CGRs of Alloy 182 weld metal in the PWR environment. The CGRs of Alloy 182 in the PWR environment are a factor of {approx}5 higher than those of Alloy 600 in air under the same loading conditions. The stress corrosion cracking for the Alloy 182 weld is close to the average behavior of Alloy 600 in the PWR environment. The weld orientation was found to have a profound effect on the magnitude of crack growth: cracking was found to propagate faster along the dendrites than across them. The existing CGR data for Ni-alloy weld metals have been compiled and evaluated to establish the effects of key material, loading, and environmental parameters on CGRs in PWR environments. The results from the present study are compared with the existing CGR data for Ni-alloy welds to determine the relative susceptibility of the specific Ni-alloy weld to environmentally enhanced cracking.

  10. Analysis of PWR auxiliary coolant: determination of chloride in borax/nitrite solution by known addition - known dilution potentiometry

    International Nuclear Information System (INIS)

    Midgley, D.; Gatford, C.

    1989-11-01

    Chloride concentrations of 75-250 μg 1 -1 have been determined in simulated PWR auxiliary coolant containing 1000 mg l -1 each of sodium tetraborate and sodium nitrite. The effects of the two main components of the coolant solution on a variety of chloride-selective electrodes have been studied. Sodium tetraborate posed no problem except through its effect on the pH, which is easily adjusted. Such high concentrations of nitrite, however, caused significant deviations in e.m.f. for all the electrodes and marked tarnishing of the electroactive membrane after only one or two measurements. Sulphamic acid was selected as the best means of removing nitrite and silver chloride electrodes were preferred over mercury(I) chloride electrodes because of their greater robustness in the conditions. At these chloride concentrations, the electrodes are operating in their non-Nernstian response regions and direct potentiometry has poor precision, even if standards could be successfully matched to samples containing such high concentrations of background material. Known addition - known dilution potentiometry was adopted, with internal calibration for both slope factor and standard potential. (author)

  11. Simulation model and methodology for calculating the damage by internal radiation in a PWR reactor; Modelo de simulacion y metodologia para el calculo del dano por irradiacion en los internos de un reactor PWR

    Energy Technology Data Exchange (ETDEWEB)

    Cadenas Mendicoa, A. M.; Benito Hernandez, M.; Barreira Pereira, P.

    2012-07-01

    This study involves the development of the methodology and three-dimensional models to estimate the damage to the vessel internals of a commercial PWR reactor from irradiation history of operating cycles.

  12. Design Development and Verification of a System Integrated Modular PWR

    International Nuclear Information System (INIS)

    Kim, S.-H.; Kim, K. K.; Chang, M. H.; Kang, C. S.; Park, G.-C.

    2002-01-01

    An advanced PWR with a rated thermal power of 330 MW has been developed at the Korea Atomic Energy Research Institute (KAERI) for a dual purpose: seawater desalination and electricity generation. The conceptual design of SMART ( System-Integrated Modular Advanced ReacTor) with a desalination system was already completed in March of 1999. The basic design for the integrated nuclear desalination system is currently underway and will be finished by March of 2002. The SMART co-generation plant with the MED seawater desalination process is designed to supply forty thousand (40,000) tons of fresh water per day and ninety (90) MW of electricity to an area with approximately a ten thousand (100,000) population or an industrialized complex. This paper describes advanced design features adopted in the SMART design and also introduces the design and engineering verification program. In the beginning stage of the SMART development, top-level requirements for safety and economics were imposed for the SMART design features. To meet the requirements, highly advanced design features enhancing the safety, reliability, performance, and operability are introduced in the SMART design. The SMART consists of proven KOFA (Korea Optimized Fuel Assembly), helical once-through steam generators, a self-controlled pressurizer, control element drive mechanisms, and main coolant pumps in a single pressure vessel. In order to enhance safety characteristics, innovative design features adopted in the SMART system are low core power density, large negative Moderator Temperature Coefficient (MTC), high natural circulation capability and integral arrangement to eliminate large break loss of coolant accident, etc. The progression of emergency situations into accidents is prevented with a number of advanced engineered safety features such as passive residual heat removal system, passive emergency core cooling system, safeguard vessel, and passive containment over-pressure protection. The preliminary

  13. Comparison of problems and experience of core operation with distorted fuel element assemblies in VVER-1000 and PWR reactors

    International Nuclear Information System (INIS)

    Afanas'ev, A.

    1999-01-01

    The main reactors leading to distortion of fuel element assemblies during reactor operation were studied. A series of actions which compensate this effect was proposed. Criteria of operation limitation in VVER-1000 and PWR reactors are described

  14. Pu recycling in a full Th-MOX PWR core. Part I: Steady state analysis

    International Nuclear Information System (INIS)

    Fridman, E.; Kliem, S.

    2011-01-01

    Research highlights: → Detailed 3D 100% Th-MOX PWR core design is developed. → Pu incineration increased by a factor of 2 as compared to a full MOX PWR core. → The core controllability under steady state conditions is demonstrated. - Abstract: Current practice of Pu recycling in existing Light Water Reactors (LWRs) in the form of U-Pu mixed oxide fuel (MOX) is not efficient due to continuous Pu production from U-238. The use of Th-Pu mixed oxide (TOX) fuel will considerably improve Pu consumption rates because virtually no new Pu is generated from thorium. In this study, the feasibility of Pu recycling in a typical pressurized water reactor (PWR) fully loaded with TOX fuel is investigated. Detailed 3-dimensional 100% TOX and 100% MOX PWR core designs are developed. The full MOX core is considered for comparison purposes. The design stages included determination of Pu loading required to achieve 18-month fuel cycle assuming three-batch fuel management scheme, selection of poison materials, development of the core loading pattern, optimization of burnable poison loadings, evaluation of critical boron concentration requirements, estimation of reactivity coefficients, core kinetic parameters, and shutdown margin. The performance of the MOX and TOX cores under steady-state condition and during selected reactivity initiated accidents (RIAs) is compared with that of the actual uranium oxide (UOX) PWR core. Part I of this paper describes the full TOX and MOX PWR core designs and reports the results of steady state analysis. The TOX core requires a slightly higher initial Pu loading than the MOX core to achieve the target fuel cycle length. However, the TOX core exhibits superior Pu incineration capabilities. The significantly degraded worth of control materials in Pu cores is partially addressed by the use of enriched soluble boron and B 4 C as a control rod absorbing material. Wet annular burnable absorber (WABA) rods are used to flatten radial power distribution

  15. The one-dimensional normalised generalised equivalence theory (NGET) for generating equivalent diffusion theory group constants for PWR reflector regions

    International Nuclear Information System (INIS)

    Mueller, E.Z.

    1991-01-01

    An equivalent diffusion theory PWR reflector model is presented, which has as its basis Smith's generalisation of Koebke's Equivalent Theory. This method is an adaptation, in one-dimensional slab geometry, of the Generalised Equivalence Theory (GET). Since the method involves the renormalisation of the GET discontinuity factors at nodal interfaces, it is called the Normalised Generalised Equivalence Theory (NGET) method. The advantages of the NGET method for modelling the ex-core nodes of a PWR are summarized. 23 refs

  16. PWR Blowdown Heat Transfer Separate-Effects Program. Thermal-Hydraulic Test Facility experimental data report for test 103

    Energy Technology Data Exchange (ETDEWEB)

    Clemons, V.D.; White, M.D.; Moore, P.A.; Hedrick, R.A.

    1978-03-07

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 103, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in a PWR system.

  17. Reactivity and neutron emission measurements of burnt PWR fuel rod samples in LWR-PROTEUS phase II

    International Nuclear Information System (INIS)

    Murphy, M. F.; Jatuff, F.; Grimm, P.; Seiler, R.; Brogli, R.; Meier, G.; Berger, H. D.; Chawla, R.

    2004-01-01

    Measurements have been made of the reactivity effects and the neutron emission rates of uranium oxide and mixed oxide burnt fuel samples having a wide range of burnup values and coming from a Pressurised Water Reactor (PWR). The reactivity measurements have been made in a PWR lattice moderated in turn with: water, a water and heavy water mixture, and water containing boron. An interesting relationship has been found between the neutron emission rate and the measured reactivity. (authors)

  18. Development and application of methods and computer codes of fuel management and nuclear design of reload cycles in PWR

    International Nuclear Information System (INIS)

    Ahnert, C.; Aragones, J.M.; Corella, M.R.; Esteban, A.; Martinez-Val, J.M.; Minguez, E.; Perlado, J.M.; Pena, J.; Matias, E. de; Llorente, A.; Navascues, J.; Serrano, J.

    1976-01-01

    Description of methods and computer codes for Fuel Management and Nuclear Design of Reload Cycles in PWR, developed at JEN by adaptation of previous codes (LEOPARD, NUTRIX, CITATION, FUELCOST) and implementation of original codes (TEMP, SOTHIS, CICLON, NUDO, MELON, ROLLO, LIBRA, PENELOPE) and their application to the project of Management and Design of Reload Cycles of a 510 Mwt PWR, including comparison with results of experimental operation and other calculations for validation of methods. (author) [es

  19. RSE-M: In-Service Inspection Rules for Mechanical Components of PWR Nuclear Islands

    International Nuclear Information System (INIS)

    2016-01-01

    The RSE-M code defines in-service inspection operations. It applies to pressure equipment used in PWR plants, as well as spare parts for such equipment. The RSE-M code does not apply to equipment made from materials other than metal. It is based on the RCC-M code for requirements relating to the design and fabrication of mechanical components. Use: The inspection rules specified in the RSE-M code describe the standard requirements of best practice within the French nuclear industry, based on its own feedback from operating several nuclear units and partly supplemented with requirements stipulated by French regulations. To date, the 58 units in France's nuclear infrastructure enforce the in-service inspection rules of the RSE-M code. Operation of 30 commissioned units in China's nuclear infrastructure, corresponding to the M310, CPR-1000 and CPR-600 reactors, is based on the RSE-M code (since 2007, use of AFCEN codes has been required by NNSA for Generation II+ reactors). Contents of the 2016 Edition: Volume I - Rules: Section A - General rules, Section B - Specific rules for class 1 components, Section C - Specific rules for class 2 or 3 components, Section D - Specific rules for components not assigned to any particular RSE-M class; Volume II - Appendices 1 to 8: Appendices 1.0 to 1.9: supporting appendices for the general requirements, Appendix 2.1: appendix associated with chap. 2000 Requalifications, Hydraulic Proof Tests and Hydraulic Tests, Appendices 4.1 to 4.4: appendices associated with chap. 4000 Examination techniques, Appendices 5.1 to 5.8 and RPP2: appendices associated with chap. 5000 Mechanical and Materials, Appendices 8.1 to 8.2: appendices associated with chap. 8000 Maintenance Operations; Volume III: Appendix 3.1 - Visit tables: main primary and secondary systems, EPR pre-service inspection program, Class 2 or 3 vessels; Appendix 3.2 - Inspection Plans For Non-Nuclear Pressure Equipment

  20. Techniques and devices developed by the CEA for hot cell and in-situ examinations of PWR components and PWR fuel assembliess after irradiation

    International Nuclear Information System (INIS)

    Van Craeynest, J.C.; Leseur, A.; Lhermenier, A.; Cytermann, R.

    1981-11-01

    Within the framework of the electro-nuclear development of the PWR system, the CEA has provided itself with facilities for developing techniques for analyzing assemblies, pins and fuels. These are examinations and tests on irradiated heads and assemblies with the aid of the Fuel Examination Module (FEM), of machining of assemblies and examinations in the Celimene hot laboratory or detailed examinations and analyses on fuel elements using eddy currents, the electronic microprobe and the Fisher ''permeascope'' which enables the outline of the oxide coat present on the cladding to be followed [fr

  1. Long-term in situ corrosion investigation of Zr alloys in simulated PWR environment by electrochemical measurements

    International Nuclear Information System (INIS)

    Goehr, H.; Schaller, J.; Ruhmann, H.; Garzarolli, F.

    1996-01-01

    The corrosion behavior of Zircaloy-type alloys with different tin contents of 1.55, 0.70, and 0.55 wt% was studied at 350 C and 17 MPa in an environment similar to PWR primary water. Impedance spectra were taken at time intervals and evaluated for thickness and morphology of the oxide layer as well as for its electrical resistance. The tests without any temperature and pressure cycling showed similar oxidation behavior with repeated transitions as in discontinuously performed standard autoclave tests. Early in the pre-transition range, a dense oxide layer is formed, and fast changes of corrosion potential and electrical resistance are observed. The dense layer increases in thickness and homogeneity up to the transition, where a sudden breakdown occurs. Abrupt changes of the corrosion potential and electrical resistance were observed also at those points. After transition, a new dense layer is built up. The corrosion potential changes are caused by a decrease of the electrical corrosion current with increasing oxide layer thickness, by the formation of a potential drop over the high-resistance dense oxide layer, and by structural changes at the transition points. In general, alloys with different tin contents show similar behavior. However, they show differences in the time to transition, the kinetic constants deduced from their impedance spectra, and in the ionic and electronic resistance of the dense inner layer controlling corrosion

  2. In-plant test and evaluation of the neutron collar for verification of PWR fuel assemblies at Resende, Brazil

    International Nuclear Information System (INIS)

    Menlove, H.O.; Marzo, M.A.S.; de Almeida, S.G.; de Almeida, M.C.; Moitta, L.P.M.; Conti, L.F.; de Paiva, J.R.T.

    1985-11-01

    The neutron-coincidence collar has been evaluated for the measurement of pressurized-water reactor (PWR) fuel assemblies at the Fabrica de Elementos Combustiveis plant in Resende, Brazil. This evaluation was part of the cooperative-bilateral-safeguards technical-exchange program between the United States and Brazil. The neutron collar measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron-interrogation source. The extended evaluation took place over a period of 6 months with both scanning and single-zone measurements. The results of the tests gave a coincidence-response standard deviation of 0.7% (sigma = 1.49% for mass) for the active case and 2.5% for the passive case in 1000-s measurement times. The length measurement in the scanning mode was accurate to 0.77%. The accuracies of different calibration methods were evaluated and compared

  3. Experiment data report for semiscale Mod-1 Test S-06-2 (LOFT counterpart test). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Jr., M. L.; Collins, B. L.; Sackett, K. E.

    1977-08-01

    Recorded test data are presented for Test S-06-2 of the Semiscale Mod-1 LOFT counterpart test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying an hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-06-2 was conducted from initial conditions of 15 513 kPa and 563 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact loop to simulate emergency core coolant injection in a PWR. The heater rods in the electrically heated core were operated at an axial peak power density which was 50% of the maximum peak power density (52.5 kW/m).

  4. Experiment data report for semiscale Mod-1 test S-06-1 (LOFT counterpart test). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Collins, B. L.; Patton, Jr., M. L.; Sackett, K. E.

    1977-07-01

    Recorded test data are presented for Test S-06-1 of the Semiscale Mod-1 LOFT counterpart test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying an hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-06-1 was conducted from initial conditions of 15 568 kPa and 564 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact loop to simulate emergency core coolant injection in a PWR. The heater rods in the electrically heated core were operated at an axial peak power density which was 30% of the maximum peak power density (52.5 kW/m).

  5. VAMCIS, a new measuring channel for continuous monitoring of leak rates inside PWR steam generators

    International Nuclear Information System (INIS)

    Champion, G.; Dubail, A.; Lefevre, F.

    1988-01-01

    In order to assess the primary to secondary leakage, radioactive isotopes, formed in the primary coolant as a result of fission or neutron capture, are usually monitored in the pressurized water reactor (PWR) secondary coolant. Conventional methods mainly based on the detection of 133 Xe, tritium, and 41 Ar are widely used on French Electricite de France (EdF) PWRs. Some years ago, it appeared necessary to improve both leak rate assessments and steam generator tube rupture (SGTR) detection. A volumetric activity measuring channel inside steam (VAMCIS) has been developed for this purpose. The SGTR that occurred at the North Anna PWR has focused the attention of safety authorities on this new measuring channel. It is planned to implement VAMCIS at North Anna in order to check the leak rate variations more accurately

  6. PENGARUH KONDISI ATMOSFERIK TERHADAP PERHITUNGAN PROBABILISTIK DAMPAK RADIOLOGI KECELAKAAN PWR 1000-MWe

    Directory of Open Access Journals (Sweden)

    Pande Made Udiyani

    2015-10-01

    Full Text Available ABSTRAK PENGARUH KONDISI ATMOSFERIK TERHADAP PERHITUNGAN PROBABILISTIK DAMPAK RADIOLOGI KECELAKAAN PWR 1000-MWe.  Perhitungan dampak kecelakaan radiologi terhadap lepasan produk fisi akibat kecelakaan potensial yang mungkin terjadi di Pressurized Water Reactor (PWR diperlukan secara probabilistik. Mengingat kondisi atmosfer sangat berperan terhadap dispersi radionuklida di lingkungan, dalam penelitian ini akan dianalisis pengaruh kondisi atmosferik terhadap perhitungan probabilistik dari konsekuensi kecelakaan reaktor.  Tujuan penelitian adalah melakukan analisis terhadap pengaruh kondisi atmosfer berdasarkan model data input meteorologi terhadap dampak radiologi kecelakaan PWR 1000-MWe yang disimulasikan pada tapak yang mempunyai kondisi meteorologi yang berbeda. Simulasi menggunakan program PC-Cosyma dengan moda perhitungan probabilistik, dengan data input meteorologi yang dieksekusi secara cyclic dan stratified, dan disimulasikan di Tapak Semenanjung Muria dan Pesisir Serang. Data meteorologi diambil setiap jam untuk jangka waktu satu tahun. Hasil perhitungan menunjukkan bahwa frekuensi kumulatif  untuk model input yang sama untuk Tapak pesisir Serang lebih tinggi dibandingkan dengan Semenanjung Muria. Untuk tapak yang sama, frekuensi kumulatif model input cyclic lebih tinggi dibandingkan model stratified. Model cyclic memberikan keleluasan dalam menentukan tingkat ketelitian perhitungan dan tidak membutuhkan data acuan dibandingkan dengan model stratified. Penggunaan model cyclic dan stratified melibatkan jumlah data yang besar dan pengulangan perhitungan  akan meningkatkan  ketelitian nilai-nilai statistika perhitungan. Kata kunci: dampak kecelakaan, PWR 1000-MWe,  probabilistik,  atmosferik, PC-Cosyma   ABSTRACT THE INFLUENCE OF ATMOSPHERIC CONDITIONS TO PROBABILISTIC CALCULATION OF IMPACT OF RADIOLOGY ACCIDENT ON PWR-1000MWe. The calculation of the radiological impact of the fission products releases due to potential accidents

  7. Optimization of small long-life PWR based on thorium fuel

    Science.gov (United States)

    Subkhi, Moh Nurul; Suud, Zaki; Waris, Abdul; Permana, Sidik

    2015-09-01

    A conceptual design of small long-life Pressurized Water Reactor (PWR) using thorium fuel has been investigated in neutronic aspect. The cell-burn up calculations were performed by PIJ SRAC code using nuclear data library based on JENDL 3.2, while the multi-energy-group diffusion calculations were optimized in three-dimension X-Y-Z geometry of core by COREBN. The excess reactivity of thorium nitride with ZIRLO cladding is considered during 5 years of burnup without refueling. Optimization of 350 MWe long life PWR based on 5% 233U & 2.8% 231Pa, 6% 233U & 2.8% 231Pa and 7% 233U & 6% 231Pa give low excess reactivity.

  8. A new uncertainty reduction method for PWR cores with erbia bearing fuel

    International Nuclear Information System (INIS)

    Takeda, Toshikazu; Sano, Tadafumi; Kitada, Takanori; Kuroishi, Takeshi; Yamasaki, Masatoshi; Unesaki, Hironobu

    2008-01-01

    The concept of a PWR with erbia bearing high burnup fuel has been proposed. The erbia is added to all fuel with over 5% 235 U enrichment to retain the neutronics characteristics to that within 5% 235 U enrichment. There is a problem of the prediction accuracy of the neutronics characteristics with erbia bearing fuel because of the short of experimental data of erbia bearing fuel. The purpose of the present work is to reduce the uncertainty. A new method has been proposed by combining the bias factor method and the cross section adjustment method. For the PWR core, the uncertainty reduction, which shows the rate of reduction of uncertainty, of the k eff is 0.865 by the present method and 0.801 by the conventional bias factor method. Thus the prediction uncertainties are reduced by the present method compared to the bias factor method. (authors)

  9. An Empirical Approach to Bounding the Axial Reactivity Effects of PWR Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    O'Leary, P. M.; Scaglione, J. M.

    2001-01-01

    One of the significant issues yet to be resolved for using burnup credit (BUC) for spent nuclear fuel (SNF) is establishing a set of depletion parameters that produce an adequately conservative representation of the fuel's isotopic inventory. Depletion parameters (such as local power, fuel temperature, moderator temperature, burnable poison rod history, and soluble boron concentration) affect the isotopic inventory of fuel that is depleted in a pressurized water reactor (PWR). However, obtaining the detailed operating histories needed to model all PWR fuel assemblies to which BUC would be applied is an onerous and costly task. Simplifications therefore have been suggested that could lead to using ''bounding'' depletion parameters that could be broadly applied to different fuel assemblies. This paper presents a method for determining a set of bounding depletion parameters for use in criticality analyses for SNF

  10. Power ramp testing method for PWR fuel rod at research reactor

    International Nuclear Information System (INIS)

    Zhou Yidong; Zhang Peisheng; Zhang Aimin; Gao Yongguang; Wang Huarong

    2003-01-01

    A tentative power ramp test for short PWR fuel rod has been conducted at the Heavy Water Research Reactor (HWRR) in China Institute of Atomic Energy (CIAE). The test fuel rod was cooled by the circulating water in the test loop. The power ramp was realized by moving solid neutron-absorbing screen around the fuel rod. The linear power of the fuel rod increased from 220 W/cm to 340 W/cm with a power ramp rate of 20 W/cm/min. The power of the fuel rod was monitored by both in-core thermal and nuclear measurement sensors in the test rig. This test provides experiences for further developing the power ramp test methods for PWR fuel rods at research reactor. (author)

  11. The empirical intensity of PWR primary coolant pumps failure and repair

    International Nuclear Information System (INIS)

    Milivojevicj, S.; Riznicj, J.

    1988-01-01

    The wealth of operating experience concerning PWR type and nuclear reactors that has been regularly monitored and systematically processes since 1971, enabled an analysis of the PWR primary coolant pumps operation. Failure intensity α and repair intensity μ of the pump during its working life were calculated, as these values are necessary in order to determine the reliability and availability of the pump as the basis for analyzing its effect on the safety and efficiency of the nuclear power plant. The trend of failure intensity α follows the theoretically expected changes in α over time, and this is around 10 -5 in the majority of life-time. Repair intensity μ indicates a slow rise during life-time, i.e. its faster return to operation. (author).7 refs.; 5 figs

  12. Analysis of confinement effects for in-water seismic tests on PWR fuel assemblies

    International Nuclear Information System (INIS)

    Broc, Daniel; Queval, Jean-Claude; Rigaudeau, J.; Viallet, E.

    2001-01-01

    In the framework of a comprehensive program on the seismic behaviour of the PWR reactor cores, tests have been performed on a row of six PWR fuel assemblies, with two confinement configurations in water. Global fluid motion along the row is not allowed in the 'full confinement configuration', and is allowed in the 'lateral confinement configuration'. The seismic test results show that the impact forces at assembly grid levels are significantly smaller with the full confinement. This is due to damping, which is found to be larger in this configuration where the average fluid velocity inside the assembly (around the rods) is itself larger. We present analyses of these phenomena from theoretical and experimental standpoint. This involves both fluid models and structural models of the assembly row. (author)

  13. Hydroelastic model of PWR reactor internals SAFRAN 1 - Validation of a vibration calculation method

    International Nuclear Information System (INIS)

    Epstein, A.; Gibert, R.J.; Jeanpierre, F.; Livolant, M.

    1978-01-01

    The SAFRAN 1 test loop consists of an hydroelastic similitude of a 1/8 scale model of a 3 loop P.W.R. Vibrations of the main internals (thermal shield and core barrel) and pressure fluctuations in water thin sections between vessel and internals, and in inlet and outlet pipes, have been measured. The calculation method consists of: an evaluation of the main vibration and acoustic sources owing to the flow (unsteady jet impingement on the core barrel, turbulent flow in a water thin section). A calculation of the internal modal parameters taking into account the inertial effects of fluid (the computer codes AQUAMODE and TRISTANA have been used). A calculation of the acoustic response of the circuit (the computer code VIBRAPHONE has been used). The good agreement between the calculation and the experimental results allows using this method with better security for the prediction of the vibration levels of full scale P.W.R. internals

  14. Some thermalhydraulics of closure head adapters in a 3 loops PWR

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, F.; Daubert, O.; Hecker, M. [EDF/DER/National Hydraulics Laboratory, Chatou (France)] [and others

    1995-09-01

    In 1993 a R&D action, based on numerical simulations and experiments on PWR`s upper head was initiated. This paper presents the test facility TRAVERSIN (a scale model of a 900 MW PWR adapter) and the calculations performed on the geometry of different upper head sections with the Thermalhydraulic Finite Element Code N3S used for 2D and 3D computations. The paper presents the method followed to bring the adapter and upper head study to a successful conclusion. Two complementary approaches are performed to obtain global results on complete fluid flow in the upper head and local results on the flow around the adapters of closure head. A validation test case of these experimental and numerical tools is also presented.

  15. Study for identification of control rod drops in PWR reactors at any burnup step

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Thiago J.; Martinez, Aquilino S.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C., E-mail: tsouza@nuclear.ufrj.br, E-mail: aquilino@lmp.ufrj.br, E-mail: canedo@lmp.ufrj.br, E-mail: alessandro@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Palma, Daniel A.P., E-mail: dapalma@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    The control rod drop event in PWR reactors induces an unsafe operating condition. Therefore, in a scenario of a control rod drop is important to quickly identify the rod to minimize undesirable effects. The objective of this work is to develop an on-line method for identification of control rod drop in PWR reactors. The method consists on the construction of a tool that is based on the ex-core detector responses. Therefore, it is proposed to recognize patterns in the neutron ex-core detectors responses and thus to identify on-line a control rod drop in the core during the reactor operation. The results of the study, as well as the behavior of the detector responses, demonstrated the feasibility of this method. (author)

  16. Study of PWR reactor efficiency as a function of turbine steam extractions

    International Nuclear Information System (INIS)

    Rocha, Janine Gandolpho da; Alvim, Antonio Carlos Marques; Martinez, Aquilino Senra

    2002-01-01

    The objective of this work is to optimize the extractions of the low-pressure turbine of a PWR nuclear reactor, in order to obtain the best thermodynamic cycle efficiency. We have analyzed typical data of a 1300 MW PWR reactor, operating at 25%, 50%, 75% and 100% capacities, respectively. The first stage of this study consists of generating a mathematical model capable of describing the reactor behavior and efficiency at any power level. The second stage of this study consists of to combine the generated mathematical model in an optimization computer program that optimize the extractions flow of the low-pressure turbine until it finds the optimal system efficiency. This work does not alter the nuclear facility project in any way. (author)

  17. Study for identification of control rod drops in PWR reactors at any burnup step

    International Nuclear Information System (INIS)

    Souza, Thiago J.; Martinez, Aquilino S.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C.

    2013-01-01

    The control rod drop event in PWR reactors induces an unsafe operating condition. Therefore, in a scenario of a control rod drop is important to quickly identify the rod to minimize undesirable effects. The objective of this work is to develop an on-line method for identification of control rod drop in PWR reactors. The method consists on the construction of a tool that is based on the ex-core detector responses. Therefore, it is proposed to recognize patterns in the neutron ex-core detectors responses and thus to identify on-line a control rod drop in the core during the reactor operation. The results of the study, as well as the behavior of the detector responses, demonstrated the feasibility of this method. (author)

  18. Results of UPTF and PKL research projects for PWR plant operation

    International Nuclear Information System (INIS)

    Liebert, J.; Brand, B.; Umminger, K.; Schwarz, W.; Sgarz, G.

    1999-01-01

    The research projects UPTF (Upper Plenum Test Facility) and PKL (Primaerkreislauf) make extraordinary experimental contributions in Germany to the examination of thermo-hydraulic processes associated with accidents and shutdown procedures of PWR plants. With the full-scale mock-up of the main components of the primary system, UPTF (dismantled in 1997) was the worldwide unique test facility of its kind. For the large break loss-of-coolant accident, the results achieved in the UPTF can be applied directly to the reactor plant due to the original geometry and the pressure range identical with the PWR. For complex studies involving the interaction of the primary side with the secondary side as well as a number of technical safety and auxiliary systems, the downscaled PKL test facility is used. The results from the two test facilities are complementary owing to the different features of the rigs, and thus help improve the further understanding of the relevant processes investigated. (orig.) [de

  19. Preventive detection of incipient failure and improvement of availability of French PWR using acoustic emission

    International Nuclear Information System (INIS)

    Audenard, B.; Marini, J.

    1982-08-01

    Laboratory tests, on site experience gained on PWR during start up test as well as during nominal functioning have given FRAMATOME very great confidence in A.E. techniques for preventive detection of incidents. Loose part and leakage monitoring are already being used on an industrial basis. Crack growth detection and monitoring are still in the investigation phase and various. Research and Development programs are presently being carried out

  20. Fluid-structure coupled dynamic response of PWR core barrel during LOCA

    International Nuclear Information System (INIS)

    Lu, M.W.; Zhang, Y.G.; Shi, F.

    1991-01-01

    This paper is engaged in the Fluid-Structure Interaction LOCA analysis of the core barrel of PWR. The analysis is performed by a multipurpose computer code SANES. The FSI inside the pressure vessel is treated by a FEM code including some structural and acoustic elements. The transient in the primary loop is solved by a two-phase flow code. Both codes are coupled one another. Some interesting conclusions are drawn. (author)

  1. Studi Unjuk Kerja Pwr Di Negara Penyedia Teknologi : Kasus Korea Selatan Dan Jepang

    OpenAIRE

    Sriyana, Sriyana

    2007-01-01

    PERFORMANCE OF PWR STUDY IN THE TECHNOLOGY SUPPLIER COUNTRIES: SOUTH KOREA AND JAPAN CASE. Electricity is needed as an infrastructure to support the national economic growth. For economic development sustainability, energy alternatives should be provided. Nuclear Power Plant (NPP) become the alternative of electricity generation for optimum energy mix in Indonesia and planned to operate in the 2016. Several studies have alredy done to prepare the NPP construction. This study focused on NPP pe...

  2. Use of complex electronic equipment within radiative areas of PWR power plants: feability study

    International Nuclear Information System (INIS)

    Fremont, P.; Carquet, M.

    1988-01-01

    EDF has undertaken a study in order to evaluate the technical and economical feasibility of using complex electronic equipment within radiative areas of PWR power plants. This study lies on tests of VLSI components (Random Access Memories) under gamma rays irradiations, which aims are to evaluate the radiation dose that they can withstand and to develop a selection method. 125 rad/h and 16 rad/h tests results are given [fr

  3. Primary water chemistry improvement for radiation exposure reduction at Japanese PWR Plants

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Eiichi [Omiya Technical Institute, Saitama-ken (Japan)

    1995-03-01

    Radiation exposure during the refueling outages at Japanese Pressurized Water Reactor (PWR) Plants has been gradually decreased through continuous efforts keeping the radiation dose rates at relatively low level. The improvement of primary water chemistry in respect to reduction of the radiation sources appears as one of the most important contributions to the achieved results and can be classified by the plant operation conditions as follows

  4. Generalized perturbation theory error control within PWR core-loading pattern optimization

    International Nuclear Information System (INIS)

    Imbriani, J.S.; Turinsky, P.J.; Kropaczek, D.J.

    1995-01-01

    The fuel management optimization code FORMOSA-P has been developed to determine the family of near-optimum loading patterns for PWR reactors. The code couples the optimization technique of simulated annealing (SA) with a generalized perturbation theory (GPT) model for evaluating core physics characteristics. To ensure the accuracy of the GPT predictions, as well as to maximize the efficient of the SA search, a GPT error control method has been developed

  5. Natural vibrations of a core banel of a PWR type reactor by elements of revolution shell

    International Nuclear Information System (INIS)

    Barcellos, C.S. de.

    1980-01-01

    Aim to estimate the behavior of the cove barrel of PWR type reactors, submitted to several load conditions, their dynamic characteristic, were determined. In order to obtain the natural modes and frequencies of the core barrel, the CYLDYFE comprete code based in the finite element method, was developed. The obtained results are compared with results obtained by other programs such as SAP, ASKA and STRUDL/DYNAL and by other analytical methods. (M.C.K.) [pt

  6. Study on evaluating the reactivity worth of the control rods of the PWR 900 MWe

    International Nuclear Information System (INIS)

    Phan Quoc Vuong; Tran Vinh Thanh; Tran Viet Phu

    2015-01-01

    Control rods of a nuclear reactor are divided into two groups: shut down and power control. Reactivity worth of the control rods depends nonlinearly on the rods' compositions and positions where the rods are inserted into the core. Therefore, calculation of control rod worth is of high important. In this study, we calculated the reactivity worth of the power control rod bank of the Mitsubishi PWR 900 MWe. The results are integral and differential worth calibration of the control rods. (author)

  7. Hard alloys testing-machine for values of PWR primary coolant circuits

    International Nuclear Information System (INIS)

    Campan, J.L.; Sauze, A.

    1980-01-01

    Testing of valve parts or material used in valve fabrication and particularly seizing conditions in friction of plane surfaces coated with hard alloys of the type stellite. The testing equipment called Marguerite is composed of a hot pressurized water loop in conditions similar to PWR primary coolant circuits (320 0 C, 150 bars) and a testing-machine with measuring instruments. Testing conditions and samples are described [fr

  8. Testing device for PWR fuel irradiation Isabelle loop in the Osiris experimental reactor

    International Nuclear Information System (INIS)

    Lucot, Michel; Vidal, Henri.

    1979-01-01

    Description of an irradiation device to test PWR fuel pins in fast and thermal neutron flux. 1 to 4 pins can be irradiated in water under a pressure of 150 bar in a temperature range of 250-300 0 C, a flow of 200g/s and a power of 400W/cm for each pin. Tests include normal, exceptional, transient or accidental conditions. First tests are briefly described [fr

  9. Twenty-five years of transient counting experience in French PWR units

    International Nuclear Information System (INIS)

    Barthelet, B.; Savoldelli, D.; Fritz, R.

    2001-01-01

    For nearly twenty five years, EDF has been checking that the actual operating transients are neither more severe nor more numerous than the design basis transients. This activity of transient cycle counting and bookkeeping has enabled EDF to own a database of more than 800 reactor.years for the PWR units. The current method of transient cycle counting is presented. In the paper, we will point out the main results of transient cycle counting and lessons learned. In general, the frequencies of transients are lower than the design frequencies. In few cases, they are higher, such as the transient frequencies of the RCS lines connected to auxiliary systems often due to operating procedures or particular periodic testing. Few periodic tests were not taken into account in the design basis transient file ; they have been detected thanks to the transient cycle counting. In the last 1980's, we achieved the first updating of the design basis transient file for the PWR 900 MWe series. In the early 1990's, we updated the design basis transient file of the PWR 1300 MWe series. In fact, since design and start-up, the operating conditions have been modified (fuel cycle with stretch-out, modification of the hot leg and cold leg temperatures for the PWR 1300 MWe,...). This was the cause of many unclassified transients. In the new design basis transient file, we have created new transients and increased the frequencies of some of them. This has enabled to consider the updated design basis transient file more representative of actual operating transients. For some years, we have increasingly associated the operators with the transient cycle counting concern. We noticed progress (decreased frequencies of most transients). (authors)

  10. Influence of probabilistic safety analysis on design and operation of PWR plants

    International Nuclear Information System (INIS)

    Bastl, W.; Hoertner, H.; Kafka, P.

    1978-01-01

    This paper gives a comprehensive presentation of the connections and influences of probabilistic safety analysis on design and operation of PWR plants. In this context a short historical retrospective view concerning probabilistic reliability analysis is given. In the main part of this paper some examples are presented in detail, showing special outcomes of such probabilistic investigations. Additional paragraphs illustrate some activities and issues in the field of probabilistic safety analysis

  11. A new model for simulation of pressurizers in PWR power plants

    International Nuclear Information System (INIS)

    Madeira, A.A.

    1981-02-01

    The pressurizer of a PWR type reactor was simulated as a thermodynamical system made up of three regions with movable boundaries. The mechanisms of normal condensation, condensation induced by spray, flashing and heat exchange across the water - steam interface, were studied. Various tests have been carried out and satisfactory results were obtained when compared with those from other models and also with some available experimental data. (E.G.) [pt

  12. SAS2H Generated Isotopic Concentrations For B and W 15X15 PWR Assembly

    International Nuclear Information System (INIS)

    J.W. Davis

    1996-01-01

    This analysis is prepared by the Mined Geologic Disposal System (MGDS) Waste Package Development Department (WPDD) to provide pressurized water reactor (PWR) isotopic composition data as a function of time for use in criticality analyses. The objectives of this evaluation are to generate burnup and decay dependant isotopic inventories and to provide these inventories in a form which can easily be utilized in subsequent criticality calculations

  13. Methods and computer programs for PWR's fuel management: Programs Sothis and Ciclon

    International Nuclear Information System (INIS)

    Aragones, J.M.; Corella, M.R.; Martinez-Val, J.M.

    1976-01-01

    Methos and computer programs developed at JEN for fuel management in PWR are discussed, including scope of model, procedures for sistematic selection of alternatives to be evaluated, basis of model for neutronic calculation, methods for fuel costs calculation, procedures for equilibrium and trans[tion cycles calculation with Soth[s and Ciclon codes and validation of methods by comparison of results with others of reference (author) ' [es

  14. Zircaloy oxidation and cladding deformation in PWR-specific CORA experiments

    International Nuclear Information System (INIS)

    Minato, K.; Hering, W.; Hagen, S.

    1991-07-01

    Out-of-pile bundle experiments (zircaloy 4) are performed in the CORA facility to investigate the behavior of PWR fuel elements during severe fuel damage (SFD) accidents. Within the international cooperation the most significant phenomena such as cladding deformation, oxidation (especially the zirconium/steam reaction), melt formation, melt release, and relocation which were found in all tests have been analyzed. (orig./MM) [de

  15. Chemical and radiochemical specifications - PWR power plants; Specifications chimiques et radiochimiques - Centrales REP

    Energy Technology Data Exchange (ETDEWEB)

    Stutzmann, A. [Electricite de France (EDF), 93 - Saint-Denis (France)

    1997-07-01

    Published by EDF this document gives the chemical specifications of the PWR (Pressurized Water Reactor) nuclear power plants. Among the chemical parameters, some have to be respected for the safety. These parameters are listed in the STE (Technical Specifications of Exploitation). The values to respect, the analysis frequencies and the time states of possible drops are noticed in this document with the motion STE under the concerned parameter. (A.L.B.)

  16. Development a computer codes to couple PWR-GALE output and PC-CREAM input

    Science.gov (United States)

    Kuntjoro, S.; Budi Setiawan, M.; Nursinta Adi, W.; Deswandri; Sunaryo, G. R.

    2018-02-01

    Radionuclide dispersion analysis is part of an important reactor safety analysis. From the analysis it can be obtained the amount of doses received by radiation workers and communities around nuclear reactor. The radionuclide dispersion analysis under normal operating conditions is carried out using the PC-CREAM code, and it requires input data such as source term and population distribution. Input data is derived from the output of another program that is PWR-GALE and written Population Distribution data in certain format. Compiling inputs for PC-CREAM programs manually requires high accuracy, as it involves large amounts of data in certain formats and often errors in compiling inputs manually. To minimize errors in input generation, than it is make coupling program for PWR-GALE and PC-CREAM programs and a program for writing population distribution according to the PC-CREAM input format. This work was conducted to create the coupling programming between PWR-GALE output and PC-CREAM input and programming to written population data in the required formats. Programming is done by using Python programming language which has advantages of multiplatform, object-oriented and interactive. The result of this work is software for coupling data of source term and written population distribution data. So that input to PC-CREAM program can be done easily and avoid formatting errors. Programming sourceterm coupling program PWR-GALE and PC-CREAM is completed, so that the creation of PC-CREAM inputs in souceterm and distribution data can be done easily and according to the desired format.

  17. The main security problems encountered in the definition of the PWR 1300 MWe stage

    International Nuclear Information System (INIS)

    Guimbail, H.; Auvergnon, F.

    1980-01-01

    The main problems of security encountered in the definition of the PWR 1300 stage originated from the necessity to ensure the continuity of a stage with the preceding one, the overture to technical progress, the acceptance of responsibility for the gaines experience and the control of cost prices. A few examples show how desirable it is for a project to be managed with the design and construction rules stabilized as early as possible [fr

  18. CRISTE - a subcomputer code for axial distribution, transient, of temperatures in a reactor channel of PWR

    International Nuclear Information System (INIS)

    Silva Neto, A.J. da; Roberty, N.C.; Carmo, E.G.D. do.

    1983-12-01

    The subroutine CRISTE was developed to calculate the temperature distribution for transients in a PWR coolant. The Crank-Nicholson approximation was used for the temporal discretization and a semi-analytical spatial solution was obtained. The temperature in the cladding was simulated by a routine adapted from the permanent distribution, and was used in on iterative method, following CRISTE subroutine. (E.G.) [pt

  19. Improvement of PWR plant design in order to reduce collective doses

    International Nuclear Information System (INIS)

    Bergeron, J.-P.; Leblond, A.

    1980-01-01

    According to the experience of the starting up and the first cycle operating for both 900 MW PWR units of Fessenheim nuclear station, the authors recall some practices it is necessary to undertake or to develop in order to reduce collective radiation dose rate. Independently of already well known great subjects, they point out details which are often difficultie's sources. So, they suggest much more concerted actions by everyone who is applying directives with radiation exposure for employ [fr

  20. A digital control and monitoring system for PWR waste-disposal systems

    International Nuclear Information System (INIS)

    Ueda, Toshiharu; Fuchigami, Kazuyuki; Shimozato, Masao; Takazawa, Kazuo

    1982-01-01

    Mitsubishi Electric has developed a digital control and monitoring system for PWR waste-disposal systems. This novel system has improved operability due to its automated operations and control, and integrated supervisory functions. The system includes other features to improve operability: sequence control by a control computer, direct-digital process control, integrated supervision of operation states by a supervisory computer and a high-speed dataway, and CRT interfacing between the computer and dataway. (author)

  1. Numerical simulation of the heating and start-up of PWR nuclear power station

    International Nuclear Information System (INIS)

    Faraco-Medeiros, M.A.; Leite, C.A.T.; Ramalho, F.P.

    1992-01-01

    The start-up of a PWR nuclear power plant must be done within safety criteria and requires a simulation. The design of some equipment, cost and time can be optimized. A computer simulator, which allows control of all the equipment and variables into the operation, has been developed and is presented in this paper. The KWU procedure and an alternative for Angra II were simulated. The results are showed up. 09 refs, 03 figs. (B.C.A.)

  2. Physico-chemical characterization of aerosols produced by a PWR control rods vaporization

    International Nuclear Information System (INIS)

    Rabu, B.; Pagano, C.; Tourasse, M.; Gros d'Aillon, L.; Boucenna, A.; Boulaud, D.; Dubourg, R.

    2000-01-01

    During a PWR type reactor accident, the aerosols produced by the vaporization of the control rods condition the released fission products evolution, for instance, the iodine or the tellurium. The EMAIC experiment has to characterize the aerosols emitted during the core degradation. The IPSN and EDF finances this program, realized at the CEA Grenoble. The results should allow the simulation of the aerosols source resulting from the vaporization to introduce in the ASTEC code, serious accident codes system. (A.L.B.)

  3. Proof test on thermal and hydraulic design reliability of Japanese PWR fuel assemblies

    International Nuclear Information System (INIS)

    Akiyama, Mamoru; Inoue, Akira; Miyazaki, Keiji; Abeta, Sadaaki; Hori, Keiichi; Mukasa, Tomio; Oishi, Masao; Aoki, Toshimasa; Makihara, Yoshiaki.

    1990-01-01

    A series of departure from nucleate boiling (DNB) tests for pressurized water reactors (PWRs) was performed at the Nuclear Power Engineering Test Center. The objective was to prove the reliability of fuel assembly design by confirming the thermal margin of heat transfer. The present method for evaluating the DNB ratio in a Japanese 17 x 17 PWR core is adequate according to the newly obtained DNB test data

  4. APA: U free Pu pin in a heterogeneous assembly to improve Pu loading in a PWR - neutronic, thermo-hydraulic and manufacturing studies

    International Nuclear Information System (INIS)

    Porta, J.; Puill, A.; Bauer, M.; Matheron, P.

    1999-01-01

    After having presented the specific context of France with respect to the fuel cycle and reprocessing, the problem of plutonium fuel utilization is posed. If one of the solutions, a pressurized water reactor (PWR) with an increased moderation ratio seems possible, it entails making excessive changes to the reactor, the control systems, and the general architecture of the steam supply system. Another solution consists in modifying the fuel itself so as to eliminate conversion on 238 U by using plutonium (Pu) in a neutronically inert matrix. However, the disadvantage of this type of fuel is that it has very low Doppler and draining coefficients and a very small delayed neutron fraction. To enable using these fuels, a heterogeneous assembly has to be defined, in which standard UO 2 rods provide the physical properties required to ensure acceptable safety coefficients. (author)

  5. Product Evaluation Task Force Phase Two report for BWR/PWR dissolver wastes

    International Nuclear Information System (INIS)

    Francis, A.J.

    1990-01-01

    It has been proposed that all Intermediate Level Wastes arising at Sellafield should be encapsulated prior to ultimate disposal. The Product Evaluation Task Force (PETF) was set up to investigate possible encapsulants and to produce an adequate data base to justify the preferred matrices. This report details the work carried out, under Phase 2 of the Product Evaluation Task Force programme, on BWR/PWR Dissolver Wastes. Three possible types of encapsulants for BWR/PWR Dissolver Wastes:- Inorganic cements, Polymer cements and Polymers are evaluated using the Kepner Tregoe decision analysis technique. This technique provides a methodology for scoring and ranking alternative options and evaluating any risks associated with an option. The analysis shows that for all four stages of waste management operations ie Storage, Transport, handling and emplacement, Disposal and Process, cement matrices are considerably superior to other potential matrices. A matrix, consisting of three parts Blast Furnace Slag (BFS) to one part Ordinary Portland Cement (OPC), is recommended for Phase 3 studies on BWR/PWR Dissolver Wastes. (author)

  6. Modeling of PWR plant by multilevel flow model and its application in fault diagnosis

    International Nuclear Information System (INIS)

    Ouyang, Jun; Yoshikawa, Hidekazu; Zhou, Yangping; Yang Ming

    2005-01-01

    The paper describes the application of Multilevel Flow Modeling (MFM) - a modeling method in means-end and part-whole way, in interface design of supervisory control of Pressurized Water Reactor (PWR) plant, and automatic real-time fault diagnosis of PWR accident. The MFM decomposes the complex plant process from the main goal to each component at multiple levels to represent the contribution of each component to the whole system to make clear how the main goal of the system is achieved. The plant process is described abstractly in function level by mass, energy and information flows, which represent the interaction between different components and enable the causal reasoning between functions according to the flow properties. Thus, in the abnormal status, a goal-function-component oriented fault diagnosis can be performed with the model at a very quick speed and abnormal alarms can be fully explained by the reasoning relationship of the model. In this paper, an interface design of the PWR plant is built by the conception of means-end nad part-whole by using MFM, and several simulation cases are used for evaluating the fault diagnosis performance. The results show that the system has a good ability to detect and diagnose accidents timely before reactor trip. (author)

  7. Aging management of PWR reactor internals in U.S. plants

    International Nuclear Information System (INIS)

    Amberge, K.J.; Demma, A.

    2015-01-01

    This paper describes the development, aging management strategies and inspection results of the Pressurized Water Reactor (PWR) vessel internals inspection and evaluation guidelines. The goal of these guidelines is to provide PWR owners with robust aging management strategies to monitor degradation of internals components to support life extension as well as the current period of operation and power up-rate activities. The implementation of these guidelines began in 2010 within the U.S. PWR fleet and several examinations have been performed since. Examples of inspection results are presented for selected vessel internals components and are compared with simulation results. In summary, to date there have been no observations of austenitic stainless steel stress corrosion cracking (SCC), which is consistent with expectations based on the current understanding of the mechanism. Observations of irradiation assisted stress corrosion cracking (IASCC) have been limited and only found in baffle former bolting. Additionally, no macroscopic effects or global observations of void swelling impacts on general conditions of reactor internal hardware have been observed. (authors)

  8. RNL NDT studies related to PWR pressure vessel inlet nozzle inspection

    International Nuclear Information System (INIS)

    Rogerson, A.; Poulter, L.N.J.; Clough, P.; Cooper, A.

    1984-01-01

    Non-destructive examinations of the Reactor Pressure Vessel (RPV) of a Pressurized Water Reactor (PWR) play an important role in assuring vessel integrity throughout its operational life. Automated ultrasonic techniques for the detection and sizing of flaws in thick-section seam welds and near-surface regions in a PWR RPV have been under development at RNL for some time. Techniques for the inspection of complex geometry welds and other regions of the vessel are now being assessed and further developed as part of the UK NDT development programme in support of the Sizewell PWR. One objective of this programme is to demonstrate that the range of ultrasonic techniques already shown to be effective for the inspection of seam welds and inlet nozzle corner regions, through exercises such as the Defect Detection Trials, can also be effective for inspection of these other vessel regions. The nozzle-to-vessel welds and nozzle crotch corners associated with the RPV water inlet and outlet nozzles are two such regions being examined in this programme. In this paper, a review is given of the work performed at RNL in the development of a laboratory-based inspection system for inlet nozzle inspection. The main features of the system in its current stage of development are explained. (author)

  9. Development of a thermal-hydraulic code for reflood analysis in a PWR experimental loop

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Sabrina P.; Mesquita, Amir Z.; Rezende, Hugo C., E-mail: sabrinapral@gmail.com, E-mail: amir@cdtn.brm, E-mail: hcr@cdtn.br, E-mail: hcr@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Palma, Daniel A.P., E-mail: dapalma@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    A process of fundamental importance in the event of Loss of Coolant Accident (LOCA) in Pressurized Water nuclear Reactors (PWR) is the reflood of the core or rewetting of nuclear fuels. The Nuclear Technology Development Center (CDTN) has been developing since the 70’s programs to allow Brazil to become independent in the field of reactor safety analysis. To that end, in the 80’s was designed, assembled and commissioned one Rewetting Test Facility (ITR in Portuguese). This facility aims to investigate the phenomena involved in the thermal hydraulic reflood phase of a Loss of Coolant Accident in a PWR nuclear reactor. This work aim is the analysis of physical and mathematical models governing the rewetting phenomenon, and the development a thermo-hydraulic simulation code of a representative experimental circuit of the PWR reactors core cooling channels. It was possible to elaborate and develop a code called REWET. The results obtained with REWET were compared with the experimental results of the ITR, and with the results of the Hydroflut code, that was the old program previously used. An analysis was made of the evolution of the wall temperature of the test section as well as the evolution of the front for two typical tests using the two codes calculation, and experimental results. The result simulated by REWET code for the rewetting time also came closer to the experimental results more than those calculated by Hydroflut code. (author)

  10. Study on Reactor Physics Characteristic of the PWR Core Using UO2

    International Nuclear Information System (INIS)

    Tukiran Surbakti

    2009-01-01

    Study on reactor physics characteristic of the PWR core using UO 2 fuel it is necessary to be done to know the characteristic of geometry, condition and configuration of pin cell in the fuel assembly Because the geometry, configuration and condition of the pin cell in fuel core determine the loading strategy of in-core fuel management Calculation of k e ff is a part of the neutronic core parameter calculation to know the reactor physics characteristic. Generally, core calculation is done using computer code starts from modelling one unit fuel lattice cell, fuel assembly, reflector, irradiation facility and until core reactor. In this research, the modelling of pin cell and fuel assembly of the PWR 17 ×17 is done homogeneously. Calculation of the k-eff is done with variation of the fuel volume fraction, fuel pin diameter, fuel enrichment. The calculation is using by NITAWL and CENTRM, and then the results will be compared to KENOVI code. The result showed that the value of k e ff for pin cell and fuel assembly PWR 17 ×17 is not different significantly with homogenous and heterogenous models. The results for fuel volume fraction of 0.5; rod pitch 1.26 cm and fuel pin diameter of 9.6 mm is critical with burn up of 35,0 GWd/t. The modeling and calculation method accurately is needed to calculation the core physic parameter, but sometimes, it is needed along time to calculate one model. (author)

  11. PWR Users Group 10 CFR 61 Waste Form Requirements Compliance Test Program

    International Nuclear Information System (INIS)

    Rosenlof, R.C.

    1985-01-01

    In January of 1984, a PWR Users Group was formed to initiate a 10 CFR 61 Waste Form Requirements Compliance Test Program on a shared cost basis. The original Radwaste Solidification Systems sold by ATCOR ENGINEERED SYSTEMS, INC. to the utilities were required to produce a free-standing monolith with no free water. None of the other requirements of 10 CFR 61 had to be met. Current regulations, however, have substantially expanded the scope of the waste form acceptance criteria. These new criteria required that generators of radioactive waste demonstrate the ability to produce waste forms which meet certain chemical and physical requirements. This paper will present the test program used and the results obtained to insure 10 CFR 61 compliance of the three (3) typical waste streams generated by the ATCOR PWR Users Group's plants. The primary objective of the PWR Users Group was not to maximize waste loading within the masonry cement solidification media, but to insure that the users Radwaste Solidification System is capable of producing waste forms which meet the waste form criteria of 10 CFR 61. A description of the laboratory small sample certification program and the actual full scale pilot plant verification approach used is included in this paper. Also included is a discussion of the development of a Process Control Program to ensure the reproducibility of the test results with actual waste

  12. PWR reactor pressure vessel internals license renewal industry report; revision 1. Final report

    International Nuclear Information System (INIS)

    Schwirian, R.; Robison, G.

    1994-07-01

    The U.S. nuclear power industry, through coordination by the Nuclear Management and Resources Council (NUMARC), and sponsorship by the U.S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI), has evaluated age-related degradation effects for a number of major plant systems, structures and components, in the license renewal technical Industry Reports (IRs). License renewal applicants may choose to reference these IRs in support of their plant-specific license renewal applications, as an equivalent to the integrated plant assessment provisions of the license renewal rule (10 CFR Part 54). Pressurized water reactor (PWR) reactor pressure vessel (RPV) internals designed by all three U.S. PWR nuclear steam supply system vendors have been evaluated relative to the effects of age-related degradation mechanisms; the capability of current design limits; inservice examination, testing, repair, refurbishment, and other programs to manage these effects; and the assurance that these internals can continue to perform their intended safety functions in the license renewal term. This industry report (IR), one of a series of ten, provides a generic technical basis for evaluation of PWR reactor pressure vessel internals for license renewal

  13. Development of a thermal-hydraulic code for reflood analysis in a PWR experimental loop

    International Nuclear Information System (INIS)

    Alves, Sabrina P.; Mesquita, Amir Z.; Rezende, Hugo C.; Palma, Daniel A.P.

    2017-01-01

    A process of fundamental importance in the event of Loss of Coolant Accident (LOCA) in Pressurized Water nuclear Reactors (PWR) is the reflood of the core or rewetting of nuclear fuels. The Nuclear Technology Development Center (CDTN) has been developing since the 70’s programs to allow Brazil to become independent in the field of reactor safety analysis. To that end, in the 80’s was designed, assembled and commissioned one Rewetting Test Facility (ITR in Portuguese). This facility aims to investigate the phenomena involved in the thermal hydraulic reflood phase of a Loss of Coolant Accident in a PWR nuclear reactor. This work aim is the analysis of physical and mathematical models governing the rewetting phenomenon, and the development a thermo-hydraulic simulation code of a representative experimental circuit of the PWR reactors core cooling channels. It was possible to elaborate and develop a code called REWET. The results obtained with REWET were compared with the experimental results of the ITR, and with the results of the Hydroflut code, that was the old program previously used. An analysis was made of the evolution of the wall temperature of the test section as well as the evolution of the front for two typical tests using the two codes calculation, and experimental results. The result simulated by REWET code for the rewetting time also came closer to the experimental results more than those calculated by Hydroflut code. (author)

  14. Determination of welding parameters for execution of weld overlayer on PWR nuclear reactor nozzles

    International Nuclear Information System (INIS)

    Ribeiro, Gabriela M.; Lima, Luciana I.; Quinan, Marco A.; Schvartzman, Monica M.

    2009-01-01

    In the PWR reactors, nickel based dissimilar welds have been presented susceptibilities the stress corrosion (S C). For the mitigation the problem a deposition of weld layers on the external surface of the nozzle is an alternative, viewing to provoke the compression of the region subjected to S C. This paper presents a preliminary study on the determination of welding parameters to obtain these welding overlayers. Welding depositions were performed on a test piece welded with nickel 182 alloy, simulating the conditions of a nozzle used in a PWR nuclear power plant. The welding process was the GTAW (Gas Tungsten Arc Welding), and a nickel 52 alloy as addition material. The overlayers were performed on the base metals, carbon steel an stainless steel, changing the welding parameters and verifying the the time of each weld filet. After that, the samples were micro structurally characterized. The macro structures and the microstructures obtained through optical microscopy and Vickers microhardness are presented. The preliminary results make evident the good weld quality. However, a small weld parameters influence used in the base material microstructure (carbon steel and stainless steel). The obtained results in this study will be used as reference in the construction of a mock up which will simulate all the conditions of a pressurizer nozzle of PWR reactor

  15. Effect of transplutonium doping on approach to long-life core in uranium-fueled PWR

    International Nuclear Information System (INIS)

    Peryoga, Yoga; Saito, Masaki; Artisyuk, Vladimir

    2002-01-01

    The present paper advertises doping of transplutonium isotopes as an essential measure to improve proliferation-resistance properties and burnup characteristics of UOX fuel for PWR. Among them 241 Am might play the decisive role of burnable absorber to reduce the initial reactivity excess while the short-lived nuclides 242 Cm and 244 Cm decay into even plutonium isotopes, thus increasing the extent of denaturation for primary fissile 239 Pu in the course of reactor operation. The doping composition corresponds to one discharged from a current PWR. For definiteness, the case identity is ascribed to atomic percentage of 241 Am, and then the other transplutonium nuclide contents follow their ratio as in the PWR discharged fuel. The case of 1 at% doping to 20% enriched uranium oxide fuel shows the potential of achieving the burnup value of 100 GWd/tHM with about 20% 238 Pu fraction at the end of irradiation. Since so far, americium and curium do not require special proliferation resistance measures, their doping to UOX would assist in introducing nuclear technology in developing countries with simultaneous reduction of accumulated minor actinides stockpiles. (author)

  16. PWR station blackout transient simulation in the INER integral system test facility

    International Nuclear Information System (INIS)

    Liu, T.J.; Lee, C.H.; Hong, W.T.; Chang, Y.H.

    2004-01-01

    Station blackout transient (or TMLB' scenario) in a pressurized water reactor (PWR) was simulated using the INER Integral System Test Facility (IIST) which is a 1/400 volumetrically-scaled reduce-height and reduce-pressure (RHRP) simulator of a Westinghouse three-loop PWR. Long-term thermal-hydraulic responses including the secondary boil-off and the subsequent primary saturation, pressurization and core uncovery were simulated based on the assumptions of no offsite and onsite power, feedwater and operator actions. The results indicate that two-phase discharge is the major depletion mode since it covers 81.3% of the total amount of the coolant inventory loss. The primary coolant inventory has experienced significant re-distribution during a station blackout transient. The decided parameter to avoid the core overheating is not the total amount of the coolant inventory remained in the primary core cooling system but only the part of coolant left in the pressure vessel. The sequence of significant events during transient for the IIST were also compared with those of the ROSA-IV large-scale test facility (LSTF), which is a 1/48 volumetrically-scaled full-height and full-pressure (FHFP) simulator of a PWR. The comparison indicates that the sequence and timing of these events during TMLB' transient studied in the RHRP IIST facility are generally consistent with those of the FHFP LSTF. (author)

  17. Liquid radioactive waste processing improvement of PWR nuclear power plants; Melhorias no processamento de rejeitos liquidos radioativos de usinas nucleares PWR

    Energy Technology Data Exchange (ETDEWEB)

    Nery, Renata Wolter dos Reis; Martinez, Aquilino Senra; Monteiro, Jose Luiz Fontes [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: wolter@eletronuclear.gov.br; monteiro@peq.coppe.ufrj.br; aquilinosenra@lmp.ufrj.br

    2005-07-01

    The study evaluate an inorganic ion exchange to process the low level liquid radwaste of PWR nuclear plants, so that the level of the radioactivity in the effluents and the solid waste produced during the treatment of these liquid radwaste can be reduced. The work compares two types of ion exchange materials, a strong acid cation exchange resin, that is the material typically used to remove radionuclides from PWR nuclear plants wastes, and a mordenite zeolite. These exchange material were used to remove cesium from a synthetic effluent containing only this ion and another effluent containing cesium and cobalt. The breakthrough curves of the zeolite and resin using a fix bed reactor were compared. The results demonstrated that the zeolite is more efficient than the resin in removing cesium from a solution containing cesium and cobalt. The results also showed that a bed combining zeolite and resin can process more volume of an effluent containing cesium and cobalt than a bed resin alone. (author)

  18. The french 900 MWe PWR PSA results and specificities

    International Nuclear Information System (INIS)

    Lanore, J.M.

    1990-01-01

    A probabilistic Safety Assessment has been performed by the Safety Analysis Department of CEA for a 900 MWe standardized plant. The paper presents the objectives, the scope of the study and the level 1 results. Some general insights are drawn, especially the benefit related to the implementation of emergency procedures and the importance of risk during shutdown situations

  19. Secondary water chemistry control practices and results of the Japanese PWR plants

    International Nuclear Information System (INIS)

    Maeda, Akihiro; Shoda, Yasuhiko; Ishihara, Nobuo; Murata, Kazutoyo; Fujiwara, Hiroyuki; Hayakawa, Hitoshi; Matsuda, Tadashi

    2012-09-01

    In Japan, since the start of the operation of the first PWR plant, Mihama Unit-1 in 1970, 24 PWR plants have been built by 2010, and all of them are in operation. Due to the plant-specific needs of management, and by flexibly incorporating the state-of-the-art insights into the design, the system configurations of the plants vary so many as 15 types. Meanwhile, the geographical feature of Japan makes all the Japanese PWR plants to have condensers cooled by sea water, and all the plants have a common system with a full-flow Condensate Polisher System (CPS). To prevent corrosion, continued improvements of the secondary water chemistry management has been performed like other countries, and one of the major features of the Japanese PWR plants is an enhanced provision for the condenser leakage. The water quality of SG (Steam Generator) has been significantly improved by the provision for the sea water leakage, in combination with other improvements in water chemistry management. Also in Japan, almost all of the treatments of the spent polisher resin and the wastewater are performed within the power plant sites. To facilitate the treatment of the waste water and the regeneration of the spent resins, either ammonia or ETA (Ethanol Amine) is selected as the pH adjustment agent for the secondary system water. Also at the ammonia treatment, high pH accomplishes the inhibition of the piping wall thinning and the lower iron transportation into SGs. In addition, the iron transported into the SG is removed by the chemical conditioning treatment called ASCA (Advanced Scale Conditioning Agent). This provides the effective recovery of the SG heat-transfer performance, and the improved SG support plate BEC (Broached Egg Crate) hole blockage rates. Basically in Japan, the secondary water chemistry management has been improved based on a single basic specification, for the variety of the plant configurations, with the plant-specific investigations and analyses. This paper summarizes

  20. Design of a PWR for long cycle and direct recycling of spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Nader M.A., E-mail: mnader73@yahoo.com

    2015-12-15

    Highlights: • Single-batch loading PWR with a new fuel assembly for 36 calendar months cycle was designed. • The new fuel assembly is constructed from a number of CANDU fuel bundles. • This design enables to recycle the spent fuel directly in CANDU reactors for high burnup. • Around 56 MWd/kgU burnup is achieved from fuel that has average enrichment of 4.8 w/o U-235 using this strategy. • Safety parameters such as the power distribution and CANDU coolant void reactivity were considered. - Abstract: In a previous work, a new design was proposed for the Pressurized Water Reactor (PWR) fuel assembly for direct use of the PWR spent fuel without processing. The proposed assembly has four zircaloy-4 tubes contains a number of 61-element CANDU fuel bundles (8 bundles per tube) stacked end to end. The space between the tubes contains 44 lower enriched UO{sub 2} fuel rods and 12 guide tubes. In this paper, this assembly is used to build a single batch loading 36-month PWR and the spent CANDU bundles are recycled in the on power refueling CANDU reactors. The Advanced PWR (APWR) is considered as a reference design. The average enrichment in the core is 4.76%w U-235. IFBA and Gd{sub 2}O{sub 3} as burnable poisons are used for controlling the excess reactivity and to flatten the power distribution. The calculations using MCNPX showed that the PWR will discharge the fuel with average burnup of 31.8 MWd/kgU after 1000 effective full power days. Assuming a 95 days plant outage, 36 calendar months can be achieved with a capacity factor of 91.3%. Good power distribution in the core is obtained during the cycle and the required critical boron concentration is less than 1750 ppm. Recycling of the discharged CANDU fuel bundles that represents 85% of the fuel in the assembly, in CANDU-6 or in 700 MWe Advanced CANDU Reactor (ACR-700), an additional burnup of about 31 or 26 MWd/kgU burnup can be achieved, respectively. Averaging the fuel burnup on the all fuel in the PWR

  1. Safety functions and component classification for BWR, PWR and PTR

    International Nuclear Information System (INIS)

    1979-01-01

    The Safety Guide forms part of the IAEA programme, referred to as the NUSS programme (Nuclear Safety Standards), for establishing Codes of Practice and Safety Guides relating to thermal neutron power plants. The present Safety Guide has the following chapters: safety functions, ranking of safety functions, assignment of safety class requirements. Design requirements for structural integrity of boundaries of fluid-retaining components are also discussed

  2. Verification and validation of a numeric procedure for flow simulation of a 2x2 PWR rod bundle

    International Nuclear Information System (INIS)

    Santos, Andre A.C.; Barros Filho, Jose Afonso; Navarro, Moyses A.

    2011-01-01

    Before Computational Fluid Dynamics (CFD) can be considered as a reliable tool for the analysis of flow through rod bundles there is a need to establish the credibility of the numerical results. Procedures must be defined to evaluate the error and uncertainty due to aspects such as mesh refinement, turbulence model, wall treatment and appropriate definition of boundary conditions. These procedures are referred to as Verification and Validation (V and V) processes. In 2009 a standard was published by the American Society of Mechanical Engineers (ASME) establishing detailed procedures for V and V of CFD simulations. This paper presents a V and V evaluation of a numerical methodology applied to the simulation of a PWR rod bundle segment with a split vane spacer grid based on ASMEs standard. In this study six progressively refined meshes were generated to evaluate the numerical uncertainty through the verification procedure. Experimental and analytical results available in the literature were used in this study for validation purpose. The results show that the ASME verification procedure can give highly variable predictions of uncertainty depending on the mesh triplet used for the evaluation. However, the procedure can give good insight towards optimization of the mesh size and overall result quality. Although the experimental results used for the validation were not ideal, through the validation procedure the deficiencies and strengths of the presented modeling could be detected and reasonably evaluated. Even though it is difficult to obtain reliable estimates of the uncertainty of flow quantities in the turbulent flow, this study shows that the V and V process is a necessary step in a CFD analysis of a spacer grid design. (author)

  3. Dose trend analysis of the PWR nuclear power plants

    International Nuclear Information System (INIS)

    Cernilogar Radez, M.; Janzekovic, H.; Krizman, M.

    2002-01-01

    The analyses of occupational dose trends in Krsko NPP in the period from 1995 to 2001 are given in comparison to the worldwide data. The Central Dose Register of Workers in Nuclear Installations at the Slovenian Nuclear Safety Administration enables the comprehensive dose trend analysis of the occupational doses in Krsko NPP. The time dose trend of the collective annual effective dose at the Krsko NPP shows somehow different trend than the trends of the ISOE data [1]. The performance indicators describing dose data distributions related to the radiation protection standards [2, 3] are discussed.(author)

  4. Spent fuel data base: commercial light water reactors. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Hauf, M.J.; Kniazewycz, B.G.

    1979-12-01

    As a consequence of this country's non-proliferation policy, the reprocessing of spent nuclear fuel has been delayed indefinitely. This has resulted in spent light water reactor (LWR) fuel being considered as a potential waste form for disposal. Since the Nuclear Regulatory Commission (NRC) is currently developing methodologies for use in the regulation of the management and disposal of high-level and transuranic wastes, a comprehensive data base describing LWR fuel technology must be compiled. This document provides that technology baseline and, as such, will support the development of those evaluation standards and criteria applicable to spent nuclear fuel.

  5. Gibbs and Hill Standard Safety Analysis Report, GIBBSSAR. License application, volume 1: chapters 1--3 (section 7)

    International Nuclear Information System (INIS)

    1977-01-01

    License application for the GIBBSSAR Standard Plant is presented. The reactor used with the GIBBSSAR balance-of-plant system is the Westinghouse 3800 MW(t) PWR. This portion of the application includes a general plant description; site characteristics; and design of structures, components, equipment and systems

  6. Safety passive system in designing reduced scale of a PWR by genetic algorithm; Sistema de seguranca passiva em escala reduzida de um PWR projetado por algoritmo genetico

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Joao J. da; Alvim, Antonio Carlos M. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: jcunha@con.ufrj.br; alvim@con.ufrj.br; Lapa, Celso Marcelo Franklin [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil). Div. de Reatores. Programa de Pos-graduacao]. E-mail: lapa@ien.gov.br

    2005-07-01

    This paper presents the concept 'Designing by Genetic Algorithms (DbyGA)' applied on a new reduced scale system problem. The designing problem of a passive safety thermal-hydraulic system, considering dimensional and operational constraints, has been solved. Take account the passive safety characteristics of the last nuclear reactor generation, a PWR core under natural circulation is used in order to demonstrate the methodology applicability. The results revealed that some solutions (reduced scale system DbyGA) are capable of reproducing, both accurately and simultaneously, many of the physical phenomena that occur in real scale and operating conditions. However the results showed, in the non-trivial flow patterns simulation case study, some deficiencies in the DbyGA approach. These aspects revel important methodological possibilities to DbyGA performance improvement. (author)

  7. Study of the distribution of hydrogen in a PWR containment with CFD codes; Estudio de la distribucion de hidrogeno en una contencion PWR con codigos CFD

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, G.; Martinez, R. M.; Fernandez, K.; Morato, D. J.; Bocanegra Melian, R.; Mena, L.; Queral, C.

    2014-07-01

    During the development of a severe accident in a PWR reactor can be generated, large quantities of hydrogen by the oxidation of metals present in the nucleus, mainly the zirconium fuel pods. This hydrogen, along with steam and other gases, can be released to the atmosphere of contention by a leak or break in the primary circuit and achieving conditions in which combustion may occur. Combustion causes thermal and pressure loads that can damage the security systems and the integrity of the containment building, last barrier of confinement of radioactive materials. The main condition that defines the characteristics of the combustion is the concentration of species, detailed knowledge of the distribution of hydrogen is very important to correctly predict the possible damage to the containment in the event that there is combustion. (Author)

  8. A neural networks based ``trip`` analysis system for PWR-type reactors; Um sistema de analise de ``trip`` em reatores PWR usando redes neuronais

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Antonio Carlos Pinto Dias

    1993-12-31

    The analysis short after automatic shutdown (trip) of a PWR-type nuclear reactor takes a considerable amount of time, not only because of the great number of variables involved in transients, but also the various equipment that compose a reactor of this kind. On the other hand, the transients`inter-relationship, intended to the detection of the type of the accident is an arduous task, since some of these accidents (like loss of FEEDWATER and station BLACKOUT, for example), generate transients similar in behavior (as cold leg temperature and steam generators mixture levels, for example). Also, the sequence-of-events analysis is not always sufficient for correctly pin point the causes of the trip. (author) 11 refs., 39 figs.

  9. Optimization of thermal efficiency of nuclear central power like as PWR; Otimizacao da eficiencia termica de uma usina nuclear do tipo PWR

    Energy Technology Data Exchange (ETDEWEB)

    Lapa, Nelbia da Silva

    2005-10-15

    The main purpose of this work is the definition of operational conditions for the steam and power conservation of Pressurized Water Reactor (PWR) plant in order to increase its system thermal efficiency without changing any component, based on the optimization of operational parameters of the plant. The thermal efficiency is calculated by a thermal balance program, based on conservation equations for homogeneous modeling. The circuit coefficients are estimated by an optimization tool, allowing a more realistic thermal balance for the plans under analysis, as well as others parameters necessary to some component models. With the operational parameter optimization, it is possible to get a level of thermal efficiency that increase capital gain, due to a better relationship between the electricity production and the amount of fuel used, without any need to change components plant. (author)

  10. The way ahead: Success factors - PWR evolution in France

    International Nuclear Information System (INIS)

    Charbonneau, S.

    1990-01-01

    The first of the model N4 reactors will be commissioned in the early 1990S. This model benefits from experience gained in the design, construction and operation of the large and consistent French program achieved during the last 20 years. Subsequent units to be brought on line in the 1990s will also be of the N4 design, in accordance with the French policy of standardization to maximize safety and reduce costs. Studies under way on the reactor that will follow the N4 are oriented in two main directions: additional improvements to enhance safety and more efficient use of the fissile material. These studies take into account the development of a common nuclear island by NPI, the new joint-venture between Framatome and Siemens-KWU. The author's opinion is that the French program consistency offers the best mean to help bridging KOEBERG onto the next units which ESCOM may decide to build in the future. (author)

  11. Fatigue monitoring of PWR primary loop and unclassified transients

    International Nuclear Information System (INIS)

    Kergoat, M.; L'Huby, Y.; Faidy, C.

    1994-01-01

    After more than 15 years of manual bookkeeping, EDF decided to develop an automatic device directly connected to the standard plant instrumentation. The objectives here are to present briefly the main parts of this new computer tool (SYSFAC) and to explain how the authors are proposing to solve the problem for older plants. These plants have just a manual bookkeeping, and a lot of unclassified transients. The computer tool that they are developing has to connect the past and future situations. This complementary computer system is named TNC, ''Transitoires Non Classes'' or ''Unclassified Transients'', and is developed on a PC type computer. It will be used directly by plant technicians and can be transposed to many different types of plants

  12. Fuel thermal conductivity (FTHCON). Status report. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Hagrman, D. L.

    1979-02-01

    An improvement of the fuel thermal conductivity subcode is described which is part of the fuel rod behavior modeling task performed at EG and G Idaho, Inc. The original version was published in the Materials Properties (MATPRO) Handbook, Section A-2 (Fuel Thermal Conductivity). The improved version incorporates data which were not included in the previous work and omits some previously used data which are believed to come from cracked specimens. The models for the effect of porosity on thermal conductivity and for the electronic contribution to thermal coductivity have been completely revised in order to place these models on a more mechanistic basis. As a result of modeling improvements the standard error of the model with respect to its data base has been significantly reduced.

  13. PENGEMBANGAN MODEL UNTUK SIMULASI KESELAMATAN REAKTOR PWR 1000 MWe GENERASI III+ MENGGUNAKAN PROGRAM KOMPUTER RELAP5

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-04-01

    Full Text Available Reaktor daya PWR AP1000 yang didesain oleh Westinghouse adalah reaktor Generasi III+ pertama yang telah menerima persetujuan desain dari U.S. Nuclear Regulatory Commission (NRC. Saat ini utilitas China telah memulai pembangunan beberapa unit AP1000 di dua tapak terpilih untuk rencana operasi pada 2013-2015. AP1000 sebagai desain PWR berdasarkan teknologi teruji dari desain PWR lainnya yang dibuat oleh Westinghouse dengan penguatan pada sistem keselamatan pasif dengan demikian dapat dipertimbangkan untuk dibangun di Indonesia bila mengacu pada persyaratan pada PP 43/2006 mengenai Perijinan Reaktor Nuklir. Namun demikian, desain tersebut perlu diverifikasi oleh Technical Support Organization (TSO independen sebelum dapat dibangun di Indonesia. Verifikasi dapat dilakukan menggunakan paket program RELAP5 dalam bentuk analisis kecelakaan. Selama ini analisis kecelakaan PLTN dilakukan untuk tipe PWR 1000 MWe dari generasi II atau tipe konvensional. Mengingat saat ini referensi yang menggambarkan teknologi AP1000 yang menyertakan teknologi keselamatan pasif sudah tersedia maka dilakukan kegiatan pemodelan yang nantinya dapat digunakan untuk melakukan analisis kecelakaan. Metode pengembangan model mengacu pada pedoman IAEA yang terdiri dari pengumpulan data instalasi, pengembangan engineering data dan penyusunan input deck, verifikasi dan validasi data input. Model yang berhasil dikembangkan secara umum telah mewakili sistem AP1000 secara keseluruhan dan dianggap sebagai model dasar. Model tersebut telah diverifikasi dan divalidasi dengan data desain yang terdapat pada referensi dimana respon parameter termohidraulika menunjukkan perbedaan hasil ± 3% selain untuk parameter penurunan tekanan teras yang lebih rendah 13%. Sebagai model dasar, input deck yang diperoleh dapat dikembangkan lebih lanjut dengan mengintegrasikan pemodelan sistem keselamatan, sistem proteksi, dan sistem kendali yang spesifik AP1000 untuk keperluan simulasi keselamatan yang lebih

  14. VERIFIKASI KECELAKAAN HILANGNYA ALIRAN AIR UMPAN PADA REAKTOR DAYA PWR MAJU

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-03-01

    Full Text Available AP1000 adalah reaktor daya PWR maju dengan daya listrik 1154 MW yang didesain berdasarkan kinerja teruji dari desain PWR lain oleh Westinghouse. Untuk mempersiapkan peran Pusat Teknologi Reaktor dan Keselamatan Nuklir sebagai suatu Technical Support Organization (TSO dalam hal verifikasi keselamatan, telah dilakukan kegiatan verifikasi keselamatan untuk AP1000 yang dimulai dengan verifikasi kecelakaan kegagalan pendingin sekunder. Kegiatan dimulai dengan pemodelan fitur keselamatan teknis yaitu sistem pendinginan teras pasif yang terdiri dari sistem Passive Residual Heat Removal (PRHR, tangki core makeup tank (CMT, dan tangki In-containment Refueling Water Storage Tank (IRWST. Kecelakaan kegagalan pendingin sekunder yang dipilih adalah hilangnya aliran air umpan ke salah satu pembangkit uap yang disimulasikan menggunakan program perhitungan RELAP5/SCDAP/Mod3.4. Tujuan analisis adalah untuk memperoleh sekuensi perubahan parameter termohidraulika reaktor akibat kecelakaan dimana hasil analisis yang diperoleh divalidasi dan dibandingkan dengan hasil analisis menggunakan program perhitungan LOFTRAN di dalam dokumen desain keselamatan AP1000. Hasil verifikasi menunjukkan bahwa kejadian hilangnya suplai air umpan tidak berdampak pada kerusakan teras, sistem pendingin reaktor, maupun sistem sekunder. Penukar kalor PRHR telah terverifikasi kemampuannya dalam membuang kalor peluruhan teras setelah trip reaktor. Hasil validasi dengan dokumen pembanding menunjukkan kesesuaian pada sebagian besar parameter termohidraulika. Secara umum, model PWR maju yang dilengkapi dengan sistem pendinginan teras ciri pasif yang telah dikembangkan tetap selamat ketika terjadi kecelakaan kehilangan aliran pendingin sekunder. Kata kunci: Verifikasi, hilangnya aliran air umpan, AP1000   AP1000 is a PWR power reactor with 1154 MW of electrical power that is designed based on the proven performance of the other Westinghouse PWR designs. To prepare the role of Center for

  15. SCAR - Post-Accident Simulator SIPA with safety analysis code CATHARE-2 and PWR cold shutdown state simulation

    International Nuclear Information System (INIS)

    Farvacque, M.; Faydide, B.; Dufeil, Ph.; Raimond, E.

    2003-01-01

    The use of Cathare in the simulators of pressurized water reactors has been effective since the beginning of the nineties. Scar project is the second stage of the Cathare strategy for the simulators, its main objective is the extension of the field of simulation to the accident situations in cold shutdown states. Work was carried out in 3 major areas: modelling, optimization and integration in the simulator. Throughout the project, the developments were part of a 3 stages validation strategy: -) elementary tests of the developments of new model on the N4 (1450 MW PWR); -) analytical tests and systems to ensure non regression of the validation of the physical laws of the Cathare code during the modifications carried out within the optimization stage; and -) overall tests of the SIPA-CP1 (900 MW PWR) simulator, controlled automatically by programmed scenarios including the transients which are carried out in PWR, the transients of the Regulatory Guides and the accident transients

  16. Sodium fast reactor: an asset for a PWR UOX/MOX fleet - 5327

    International Nuclear Information System (INIS)

    Tiphine, M.; Coquelet-Pascal, C.; Girieud, R.; Eschbach, R.; Chabert, C.; Grosman, R.

    2015-01-01

    Due to its low fissile content, Pu from spent MOX fuels is sometimes regarded as not recyclable in LWR. Based on the existing French nuclear infrastructure (La Hague reprocessing plant and MELOX MOX manufacturing plant), AREVA and CEA have evaluated the conditions of Pu multi recycling in a 100% LWR fleet. As France is currently supporting a Fast Reactor prototype project, scenario studies have also been conducted to evaluate the contribution of a 600 MWe SFR in the LWR fleet. These scenario studies consider a nuclear fleet composed of 8 PWR 900 MWe, with or without the contribution of a SFR, and aim at evaluating the following points: -) the feasibility of Pu multi-recycling in PWR; -) the impact on the spent fuels storage; -) the reduction of the stored separated Pu; -) the impact on waste management and final disposal. The studies have been conducted with the COSI6 code, developed by CEA Nuclear Energy Direction since 1985, that simulates the evolution over time of a nuclear power plants fleet and of its associated fuel cycle facilities and provides material flux and isotopic compositions at each point of the scenario. To multi-recycle Pu into LWR MOX and to ensure flexibility, different reprocessing strategies were evaluated by adjusting the reprocessing order, the choice of used fuel assemblies according to their burn-up and the UOX/MOX proportions. The improvement of the Pu fissile quality and the kinetic of Pu multi-recycling in SFR depending on the initial Pu quality were also evaluated and led to a reintroduction of Pu in PWR MOX after a single irradiation in SFR, still in dilution with Pu from UOX to maintain a sufficient fissile quality. (authors)

  17. PWR circuit contamination assessment tool. Use of OSCAR code for engineering studies at EDF

    Directory of Open Access Journals (Sweden)

    Benfarah Moez

    2016-01-01

    Full Text Available Normal operation of PWR generates corrosion and wear products in the primary circuit which are activated in the core and constitute the major source of the radiation field. In addition, cases of fuel failure and alpha emitter dissemination in the coolant system could represent a significant radiological risk. Radiation field and alpha risks are the main constraints to carry out maintenance and to handle effluents. To minimize these risks and constraints, it is essential to understand the behavior of corrosion products and actinides and to carry out the appropriate measurements in PWR circuits and loop experiments. As a matter of fact, it is more than necessary to develop and use a reactor contamination assessment code in order to take into account the chemical and physical mechanisms in different situations in operating reactors or at design stage. OSCAR code has actually been developed and used for this aim. It is presented in this paper, as well as its use in the engineering studies at EDF. To begin with, the code structure is described, including the physical, chemical and transport phenomena considered for the simulation of the mechanisms regarding PWR contamination. Then, the use of OSCAR is illustrated with two examples from our engineering studies. The first example of OSCAR engineering studies is linked to the behavior of the activated corrosion products. The selected example carefully explores the impact of the restart conditions following a reactor mid-cycle shutdown on circuit contamination. The second example of OSCAR use concerns fission products and disseminated fissile material behavior in the primary coolant. This example is a parametric study of the correlation between the quantity of disseminated fuel and the variation of Iodine 134 in the primary coolant.

  18. Analysis of accidental loss of pool coolant due to leakage in a PWR SFP

    International Nuclear Information System (INIS)

    Wu, Xiaoli; Li, Wei; Zhang, Yapei; Tian, Wenxi; Su, Guanghui; Qiu, Suizheng

    2015-01-01

    Highlights: • Accidental loss of pool coolant due to leakage in a PWR SFP was studied using MAAP5. • The effect of emergency ventilation on the accident progression was investigated. • The effect of emergency injection on the accident progression was discussed. - Abstract: A large loss of pool coolant/water accident may be caused by extreme accidents such as the pool wall or bottom floor punctures due to a large aircraft strike. The safety of SFP under this circumstance is very important. Large amounts of radioactive materials would be easily released into the environment if a severe accident happened in the SFP, because the spent fuel pool (SFP) in a PWR nuclear power station (NPS) is often located in the fuel handing building outside the reactor containment. To gain insight into the loss of pool coolant accident progression for a pressurized water reactor (PWR) SFP, a computational model was established by using the Modular Accident Analysis Program (MAAP5). Important factors such as Zr oxidation by air, air natural circulation and thermal radiation were considered for partial and complete drainage accidents without mitigation measures. The calculation indicated that even if the residual water level was in the active fuel region, there was a chance to effectively remove the decay heat through axial heat conduction (if the pool cooling system failed) or steam cooling (if the pool cooling system was working). For sensitivity study, the effects of emergency ventilation and water injection on the accident progression were analyzed. The analysis showed that for the current configuration of high-density storage racks, it was difficult to cool the spent fuels by air natural circulation. Enlarging the space between the adjacent assemblies was a way of increasing air natural circulation flow rate and maintaining the coolability of SFP. Water injection to the bottom of the SFP helped to recover water inventory, quenching the high temperature assemblies to prevent

  19. Impact of radiation embrittlement on integrity of pressure vessel supports for two PWR plants

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Pennell, W.E.; Robinson, G.C.; Nanstad, R.K.

    1989-01-01

    Recent data from the HFIR vessel surveillance program indicate a substantial radiation embrittlement rate effect at low irradiation temperatures (/approximately/120/degree/F) for A212-B, A350-LF3, A105-II, and corresponding welds. PWR vessel supports are fabricated of similar materials and are subjected to the same low temperatures and fast neutron fluxes (10 8 to 10 9 neutrons/cm 2 /center dot/s, E > 1.0 MeV) as those in the HFIR vessel. Thus, the embrittlement rate of these structures may be greater than previously anticipated. A study sponsored by the NRC is under way at ORNL to determine the impact of the rate effect on PWR vessel-support life expectancy. The scope includes the interpretation and application of the HFIR data, a survey of all light-water-reactor vessel support designs, and a structural and fracture-mechanics analysis of the supports for two specific PWR plants of particular interest with regard to a potential for support failure as a result of propagation of flaws. Calculations performed thus far indicate best-estimate critical flaw sizes, corresponding to 32 EFPY, of /approximately/0.2 in. for one plant and /approximately/0.4 in. for the other. These flaw sizes are small enough to be of concern. However, it appears that low-cycle fatigue is not a viable mechanism for creation of flaws of this size, and thus, presumably, such flaws would have to exist at the time of fabrication. 59 refs., 128 figs., 49 tabs

  20. Intergranular stress corrosion cracking of ion irradiated 304L stainless steel in PWR environment

    International Nuclear Information System (INIS)

    Gupta, Jyoti

    2016-01-01

    IASCC is irradiation - assisted enhancement of intergranular stress corrosion cracking susceptibility of austenitic stainless steel. It is a complex degrading phenomenon which can have a significant influence on maintenance time and cost of PWRs' core internals and hence, is an issue of concern. Recent studies have proposed using ion irradiation (to be specific, proton irradiation) as an alternative of neutron irradiation to improve the current understanding of the mechanism. The objective of this study was to investigate the cracking susceptibility of irradiated SA 304L and factors contributing to cracking, using two different ion irradiations; iron and proton irradiations. Both resulted in generation of point defects in the microstructure and thereby causing hardening of the SA 304L. Material (unirradiated and iron irradiated) showed no susceptibility to intergranular cracking on subjection to SSRT with a strain rate of 5 * 10 -8 s -1 up to 4 % plastic strain in inert environment. But, irradiation (iron and proton) was found to increase intergranular cracking severity of material on subjection to SSRT in simulated PWR primary water environment at 340 C. Correlation between the cracking susceptibility and degree of localization was studied. Impact of iron irradiation on bulk oxidation of SA 304L was studied as well by conducting an oxidation test for 360 h in simulated PWR environment at 340 C. The findings of this study indicate that the intergranular cracking of 304L stainless steel in PWR environment can be studied using Fe irradiation despite its small penetration depth in material. Furthermore, it has been shown that the cracking was similar in both iron and proton irradiated samples despite different degrees of localization. Lastly, on establishing iron irradiation as a successful tool, it was used to study the impact of surface finish and strain paths on intergranular cracking susceptibility of the material. (author) [fr

  1. Performance of PWR study in the technology supplier countries: south korea and japan case

    International Nuclear Information System (INIS)

    Sriyana

    2007-01-01

    Electricity is needed as an infrastructure to support the national economic growth. For economic development sustainability, energy alternatives should be provided. Nuclear Power Plant (NPP) become the alternative of electricity generation for optimum energy mix in Indonesia and planned to operate in the 2016. Several studies have already done to prepare the NPP construction. This study focused on NPP performance especially PWR type in Asia, namely Japan and South Korea. Methodology used in this is literature tracing and a small calculation. The energy availability per unit per year is used as a parameter for evaluating the NPP performance. This conclusion are 1) the amount of NPP - PWR type in Japan is 22 units with total operational experiences 526 reactor-years and the average energy availability factor about 70.7% per unit per year. Meanwhile for the same type South Korea has 16 unit with total operational experience 222 reactor-years and average availability factor per unit per year is about 86.9%. 2) the 1000 class of PWR type both South Korea and Japan have 14 units. The operational experiences for thi class is 170 reactor-year for South Korean and 307 reactor-year for Japan. Meanwhile the average availability factor per unit per year is about 87.0% for South Korea and 69.6% for Japan. 3) the average availability factor is closed to capacity factor, so is important for real figure in assuming the techno-economic parameters, because it will influence the result o economic calculation. (author)

  2. A new stress corrosion cracking model for Inconel 600 in PWR media

    International Nuclear Information System (INIS)

    Magnin, T.

    1993-01-01

    A model of cracking in corrosion under stress, based on corrosion-plasticity interactions at cracking points, is proposed to describe the generally intergranular breakage of Inconel 600 in PWR medium. It is shown by calculation, and verified experimentally by observations in SEM, that a pseudo-intergranular breakage connected to the formation of micro facets in zigzags along the joints is possible, as well as a completely intergranular breakage. This allows us to assume that a continuity of mechanisms exists between the trans- and intergranular cracking by corrosion under material stress. (author)

  3. Thermal Response of the 21-PWR Waste Package to a Fire Accident

    International Nuclear Information System (INIS)

    F.P. Faucher; H. Marr; M.J. Anderson

    2000-01-01

    The objective of this calculation is to evaluate the thermal response of the 21-PWR WP (pressurized water reactor waste package) to the regulatory fire event. The scope of this calculation is limited to the two-dimensional waste package temperature calculations to support the waste package design. The information provided by the sketches attached to this calculation (Attachment IV) is that of the potential design of the type of waste package considered in this calculation. The procedure AP-3.12Q.Calculations (Reference 1), and the Development Plan (Reference 24) are used to develop this calculation

  4. Stress corrosion cracking of Ni-based alloys in PWR primary water. Component surface control

    International Nuclear Information System (INIS)

    Foucault, M.

    2004-01-01

    In the PWR plant primary circuit, FRAMATOME-ANP uses several nickel-base alloys or austenitic stainless steels for the manufacture of safety components. The experience feedback of the last twenty years allows us to point out the major role played by the surface state of the components in their life duration. In this paper, we present two examples of problems encountered and solved by a surface study and the definition and implementation of a process for the surface control of the repair components. Then, we propose some ideas about the present needs in terms of analysis methods to improve the surface knowledge and the control of the manufactured components. (author)

  5. The deformation of zircaloy PWR cladding with low internal pressures, under mainly convective cooling by steam

    International Nuclear Information System (INIS)

    Hindle, E.D.; Mann, C.A.; Reynolds, A.E.

    1981-01-01

    The deformation behaviour is reported of specimens of Zircaloy PWR fuel cladding when directly heated in flowing steam. The range of internal pressures studied was 0.69-2.07 MPa; this extended earlier studies using higher pressures. The specimens were ramped and then held at a steady test temperature until rupture or until 600 seconds had elapsed. Under these conditions it was found that extended deformation occurred with pressures down to 1 MPa at temperatures up to 900 deg C. At lower pressures and higher temperatures there was no large extended deformation; this is believed to result from the effects of oxidation

  6. The continued development of the MFM suite and its practical application on a PWR system

    DEFF Research Database (Denmark)

    Thunem, Harald P-J; Zhang, Xinxin

    2015-01-01

    This paper reports on the results from the practical application of the Shape Shifter framework on the continued development of a graphical editing suite, the MFM Suite, for MFM and process model design and analysis. The primary use of the MFM Suite is diagnosis and prognosis of anomalies...... in physical processes. One of the Halden Reactor Project’s advanced NPP simulators based on a PWR is used to demonstrate the applicability of the suite in realistic situations. The paper presents a summary and suggests some plans for future research and development....

  7. Experimental stress analysis for reactor coolant pump case of PWR NPP

    International Nuclear Information System (INIS)

    Dai Xinsun

    1997-11-01

    The contents of experimental stress analysis in development for reactor coolant pump (RCP) case of PWR NPP are described. The RCP case is classified nuclear safety class 1. The electrometry and photoelastic tests provided a complete basis for the structural design and functional integrity of reactor coolant pressure foundry. The test was carried out in internal pressure, deadweight and earthquake loading and connected pipe system loading with a geometrical similarity model pump case. The detailed experimental results are provided to analyse and evaluate according to ASME code

  8. Simulation model for the dynamic behavior of the hydraUlic circuito of PWR reactors

    International Nuclear Information System (INIS)

    Hirdes, V.R.T.R.

    1987-01-01

    The present work consist of the development of a computer code for the simulations of hydraulic transients caused by stoppages of the primary coolant pumps of nuclear reactors and it applied to the hydraulic circuits typical of PWR reactor. The code calculates the time-histories of the mass flux, rotation speed, electric and hydraulic torque and dynamic head of the pumps. It can be used for any combination of active and inactive pumps. Several transients were analysed and the results were compared with comparared with data from the Angra-I nuclear power plant. The results were considered satisfactory. (author) [pt

  9. Introduction of Zirlo''TM as a structural component material in PWR

    International Nuclear Information System (INIS)

    Montes, M. A.; Pereda, R.; King, S. J.

    1998-01-01

    The more and more severe nuclear fuel operating conditions have made necessary the use of advanced fuel cladding alloys like Zirlo''TM, which allow to obtain a response clearly above Zircaloy-4 because of the elevated corrosion resistance that provides, as well as a the greater dimensional stability. The superiority in properties is also applicable to the structural components, where this dimensional stability is critical to maintain the control rod insertability. In this paper the current operating experience with Zirlo''TM as a structural component material for PWR fuel assemblies is presented, the associated advantages are detailed and, finally, the irradiation and verification programs that support these advantages are described. (Author)

  10. A calculation methodology applied for fuel management in PWR type reactors using first order perturbation theory

    International Nuclear Information System (INIS)

    Rossini, M.R.

    1992-01-01

    An attempt has been made to obtain a strategy coherent with the available instruments and that could be implemented with future developments. A calculation methodology was developed for fuel reload in PWR reactors, which evolves cell calculation with the HAMMER-TECHNION code and neutronics calculation with the CITATION code.The management strategy adopted consists of fuel element position changing at the beginning of each reactor cycle in order to decrease the radial peak factor. The bi-dimensional, two group First Order perturbation theory was used for the mathematical modeling. (L.C.J.A.)

  11. Experience in containment and leaching of PWR wastes embedded into the cement

    International Nuclear Information System (INIS)

    Bernard, Andre; Nomine, J.-C.

    1981-10-01

    The growth of the important French electro-nuclear programme (900 and 1300 MWe PWR reactors, fast neutrons) corresponds to the production of low and medium level radioactive wastes that must be efficiently solidified. The ''Laboratoire des Betons et Revetements'' of the Saclay Nuclear Study Centre has gained a certain experience on how to package such waste by means of hydraulic binders. It has also build up a data bank on the characteristics of the materials obtained. The purpose of this paper is to draw up a panorama of the actions relating the experience acquired in these fields [fr

  12. Validation of the Subchannel Code SUBCHANFLOW Using the NUPEC PWR Tests (PSBT

    Directory of Open Access Journals (Sweden)

    Uwe Imke

    2012-01-01

    Full Text Available SUBCHANFLOW is a computer code to analyze thermal-hydraulic phenomena in the core of pressurized water reactors, boiling water reactors, and innovative reactors operated with gas or liquid metal as coolant. As part of the ongoing assessment efforts, the code has been validated by using experimental data from the NUPEC PWR Subchannel and Bundle Tests (PSBT. The database includes single-phase flow bundle outlet temperature distributions, steady state and transient void distributions and critical power measurements. The performed validation work has demonstrated that the two-phase flow empirical knowledge base implemented in SUBCHANFLOW is appropriate to describe key mechanisms of the experimental investigations with acceptable accuracy.

  13. Decision tree based knowledge acquisition and failure diagnosis using a PWR loop vibration model

    International Nuclear Information System (INIS)

    Bauernfeind, V.; Ding, Y.

    1993-01-01

    An analytical vibration model of the primary system of a 1300 MW PWR was used for simulating mechanical faults. Deviations in the calculated power density spectra and coherence functions are determined and classified. The decision tree technique is then used for a personal computer supported knowledge presentation and for optimizing the logical relationships between the simulated faults and the observed symptoms. The optimized decision tree forms the knowledge base and can be used to diagnose known cases as well as to include new data into the knowledge base if new faults occur. (author)

  14. Sensitivity analysis on hot channel of PWR type reactors using matricial formalism

    International Nuclear Information System (INIS)

    Maciel, Edisson Savio G.; Andrade Lima, Fernando Roberto de; Lira, Carlos Alberto B.O.

    1995-01-01

    The matricial formalism of the perturbation theory is applied in a simplified model to study the hot channel of PWR reactors. Mass, linear momentum and energy conservation equations and appropriated heat transfer and fluid mechanics correlations describe the discretized system. After calculating system's thermalhydraulic properties, the matricial formalism is applied and the sensitivity coefficients are determined for each case of interest. Comparisons between perturbative method and direct results of the model have shown good agreement which demonstrates that the matricial formalism is an important tool for discretized system analysis. (author). 6 refs, 2 tabs

  15. An intelligent pedagogic tool for teaching the operators of PWR type reactors

    International Nuclear Information System (INIS)

    Cordier, B.; Guillermard, M.

    1990-01-01

    A tool was developed for assisting the instruction of the operators of a PWR type nuclear power plant. For achieving the objectives, an expert system and a simulator were combined. The main objective of the system is to improve the work of the operators in performing remedial actions in case of accident. The simulator applies two IBM PC AT3 and a MC 680 20 microprocessor. The use and the validation of the expert system are presented. The perspectives for the system, implanted on the Tricastin nuclear power plant, are analyzed [fr

  16. Cyclic elastic analysis of a PWR nozzle subjected to a repeated thermal shock

    International Nuclear Information System (INIS)

    Locci, J.M.; Prost, J.P.

    1979-01-01

    In the primary piping system of a PWR nuclear power plant, some nozzles are subjected to strong thermal shocks due to sudden thermal variations in the internal water flow. The thermal gradients are sufficiently high to induce general elastic plastic behaviour. The design of these nozzles using the simplified elastic plastic analysis given in the ASME III Code NB-3200 generally leads to a very high usage factor. The aim of this work is to show by giving an example that a complete cyclic elastic plastic analysis makes it possible to considerably reduce the usage factor. (orig.)

  17. MELCOR analyses of severe accident scenarios in Oconee, a B ampersand W PWR plant

    International Nuclear Information System (INIS)

    Madni, I.K.; Nimnual, S.; Foulds, R.

    1993-01-01

    This paper presents the results and insights gained from MELCOR analyses of two severe accident scenarios, a Loss of Coolant Accident (LOCA) and a Station Blackout (TMLB) in Oconee, a Babcock ampersand Wilcox (B ampersand W) designed PWR with a large dry containment, and comparisons with Source Term Code Package (STCP) calculations of the same sequences. Results include predicted timing of key events, thermal-hydraulic response in the reactor coolant system and containment, and environmental releases of fission products. The paper also explores the impact of varying concrete type, vessel failure temperature, and break location on the accident progression, containment pressurization, and environmental releases of radionuclides

  18. Improved identification to prevent transposition during operation of 900 MWe PWR reactors

    International Nuclear Information System (INIS)

    Leckner, J.M.; Dien, Y.; Cernes, A.

    1986-04-01

    Detailed human factors analysis of 900 MWe PWR control room identification systems was carried out by the Nuclear and Fossil Generation Division of Electricite de France (EDF) consequent to a series of incidents where personnel confused one plant unit, room or piece of equipment for another. Preliminary analysis uncovered coding inadequacies and suggested possible remedies. This data was used to prepare specifications for identification redesign at a pilot plant on which detailed investigations could be carried out. Recommended solutions were submitted to pilot plant operators and their opinion sollicited. Operator recommendations will be tried out on the pilot plant and adopted on a grid-wide basis if trials prove satisfactory

  19. Thermal Response of the 21-PWR Waste Package to a Fire Accident

    Energy Technology Data Exchange (ETDEWEB)

    F.P. Faucher; H. Marr; M.J. Anderson

    2000-10-03

    The objective of this calculation is to evaluate the thermal response of the 21-PWR WP (pressurized water reactor waste package) to the regulatory fire event. The scope of this calculation is limited to the two-dimensional waste package temperature calculations to support the waste package design. The information provided by the sketches attached to this calculation (Attachment IV) is that of the potential design of the type of waste package considered in this calculation. The procedure AP-3.12Q.Calculations (Reference 1), and the Development Plan (Reference 24) are used to develop this calculation.

  20. Management routes for materials arising from the decommissioning of a PWR reactor

    International Nuclear Information System (INIS)

    Klein, M.; Demeulemeester, Y.; Moers, S.; Ponnet, M.

    2001-01-01

    The management of wastes from decommissioning is described for the on-going dismantling of the BR3 PWR small reactor. The incentive is put on the radionuclides characterization, the description of the various waste streams, the conditioning techniques for low radioactive waste (LAW) to high radioactive waste (RAW), the alternative evacuation routes (recycling in the nuclear, free release by decontamination) and the minimization of secondary wastes during dismantling. Finally, some considerations are given on the overall dismantling cost and on the relative costs of the various evacuation routes. (author)

  1. Application of LBB to high energy piping systems in operating PWR

    Energy Technology Data Exchange (ETDEWEB)

    Swamy, S.A.; Bhowmick, D.C. [Westinghouse Nuclear Technology Division, Pittsburgh, PA (United States)

    1997-04-01

    The amendment to General Design Criterion 4 allows exclusion, from the design basis, of dynamic effects associated with high energy pipe rupture by application of leak-before-break (LBB) technology. This new approach has resulted in substantial financial savings to utilities when applied to the Pressurized Water Reactor (PWR) primary loop piping and auxiliary piping systems made of stainless steel material. To date majority of applications pertain to piping systems in operating plants. Various steps of evaluation associated with the LBB application to an operating plant are described in this paper.

  2. Development and validation process of the advanced main control board for next Japanese PWR plants

    International Nuclear Information System (INIS)

    Tani, M.; Ito, K.; Yokoyama, M.; Imase, M.; Okamoto, H.

    2000-01-01

    The purpose of main control room improvement is to reduce operator workload and potential human errors by offering a better working environment where operators can maximize their abilities. Japanese pressurized water reactor (PWR) utilities and Mitsubishi group have developed a touch -screen-based main control console (i.e. advanced main control room) the next generation PWRs to further improve the plant operability using a state of the art electronics technology. The advanced main control room consists of an operator console, a supervisor console and large display panels. The functional specifications were evaluated by utility operators using a prototype main control console connected to a plant simulator. (author)

  3. A feasibility assessment for incorporating of passive RHRS into large scale active PWR

    International Nuclear Information System (INIS)

    Kim, S.O.; Sub, S.Y.; Kim, Y.S.; Chang, M.H.; Park, J.K.

    1996-01-01

    A feasibility study was carried out for the possible incorporation of passive RHRS (Residual Heat Removal System) into a large-scale of active PWR plant. Four kinds of system configurations were considered. For each case its performance and impacts on plant safety, cost, licensing, operation and maintenance were evaluated. The evaluation came up with a finding of PRHRS with a gravity feed tank as most probable design concept. However, considering rearrangement of structure and pipe routing inside and outside containment, it is concluded that implementation of the PRHRS concept into well developed active plants is not desirable at present. (author). 6 refs, 7 figs, 1 tab

  4. Study on the structural integrity of a PWR vessel according to the ductile cracking instability theory

    International Nuclear Information System (INIS)

    Tarpani, Jose Ricardo; Spinelli, Dirceu

    1996-01-01

    Analytical predictions of PWR vessel instability have been made according to Linear Elastic criterion K lC and Elastic-Plastic Fracture Mechanics Ji, J 50 and J inst . Special attention was given to the influence of crack depth and length on both approaches, as well as to the data extrapolation procedures on elasto-plasticity. Simple and didactic format has been supplied for the results evaluation in terms of internal pressure, wall-through strain gradient and ductile stable crack extension. (author)

  5. Recovery actions for some abnormal and emergency transients in Westinghouse PWR plants

    International Nuclear Information System (INIS)

    Frantz, E.R.; Srinivas, V.

    1987-01-01

    A nuclear plant is expected to withstand a number of normal and abnormal transients without significant releases of radioactivity and challenges to the safety systems. Multiple equipment failures or operator errors, however, could change these events into severe accidents. This paper provides examples of some of these beyond design basis events, the potential consequences if no recovery actions are aken, and some of the operator actions that can be performed to recover the plant safely. Two of these cases are analyzed in detail for a typical Westinghouse 3-loop pressurized water reactor (PWR). The recovery actions used are consistent with the guidelines (ERGs)

  6. Development of automated generation system of accidental operating procedures for a PWR

    International Nuclear Information System (INIS)

    Artaud, J.L.

    1991-06-01

    The aim of the ACACIA project is to develop an automated generation system of accident operating procedures for a PWR. This research and development study, common at CEA and EDF, has two objectives: at mean-dated the realization of a validation tool and a procedure generation; at long-dated the dynamic generation of real time procedures. This work is consecrated at the realization of 2 prototypes. These prototypes and the technics used are described in detail. The last chapter explores the perspectives given by this type of tool [fr

  7. Electropolishing of replacement steam generator channel heads at Millstone-2 PWR

    International Nuclear Information System (INIS)

    Hudson, M.J.B.; Raney, H.; Raney, D.; Spalaris, C.N.

    1992-07-01

    A field application of EPRI-developed steam generator electropolishing technique was performed at Millstone-2 PWR. The process was qualified under previous programs on a laboratory scale, but it was thought appropriate to scale up application to full size components. Replacement of steam generators at Millstone-2 provided a unique opportunity to demonstrate that electropolishing can be applied safely and at a cost which was judged to be recoverable after a small number of fuel cycles. The project, preparation, electropolishing and cleanup, was completed at the reactor site in 25 working days. An alternate, less costly electrolyte solution was qualified for use in future applications

  8. Lateral hydraulic forces calculation on PWR fuel assemblies with computational fluid dynamics codes

    International Nuclear Information System (INIS)

    Corpa Masa, R.; Jimenez Varas, G.; Moreno Garcia, B.

    2016-01-01

    To be able to simulate the behavior of nuclear fuel under operating conditions, it is required to include all the representative loads, including the lateral hydraulic forces which were not included traditionally because of the difficulty of calculating them in a reliable way. Thanks to the advance in CFD codes, now it is possible to assess them. This study calculates the local lateral hydraulic forces, caused by the contraction and expansion of the flow due to the bow of the surrounding fuel assemblies, on of fuel assembly under typical operating conditions from a three loop Westinghouse PWR reactor. (Author)

  9. A model finite-element to analyse the mechanical behavior of a PWR fuel rod

    International Nuclear Information System (INIS)

    Galeao, A.C.N.R.; Tanajura, C.A.S.

    1988-01-01

    A model to analyse the mechanical behavior of a PWR fuel rod is presented. We drew our attention to the phenomenon of pellet-pellet and pellet-cladding contact by taking advantage of an elastic model which include the effects of thermal gradients, cladding internal and external pressures, swelling and initial relocation. The problem of contact gives rise ro a variational formulation which employs Lagrangian multipliers. An iterative scheme is constructed and the finite element method is applied to obtain the numerical solution. Some results and comments are presented to examine the performance of the model. (author) [pt

  10. Reliability analysis of PWR thermohydraulic design by the Monte Carlo method

    International Nuclear Information System (INIS)

    Silva Junior, H.C. da; Berthoud, J.S.; Carajilescov, P.

    1977-01-01

    The operating power level of a PWR is limited by the occurence of DNB. Without affecting the safety and performance of the reactor, it is possible to admit failure of a certain number of core channels. The thermohydraulic design, however, is affect by a great number of uncertainties of deterministic or statistical nature. In the present work, the Monte Carlo method is applied to yield the probability that a number F of channels submitted to boiling crises will not exceed a number F* previously given. This probability is obtained as function of the reactor power level. (Author) [pt

  11. Application of directional solidification ingot (LSD) in forging of PWR reactor vessel heads

    International Nuclear Information System (INIS)

    Benhamou, C.; Poitrault, I.

    1985-09-01

    Creusot-Loire Industrie uses this type of ingot for manufacture of Framatome 1300 and 1450 MW 4-loop PWR reactor vessel heads. This type of ingot offers a number advantages: improved internal soundness; greater chemical, structural and mechanical homogeneity of the finished part; simplified forging process. After a brief description of the pouring and solidification processes, this paper presents an analysis of the results of examinations performed on the prototype forging, as well as review of results obtained during industrial fabrication of dished heads from LSD ingots. The advantages of the LSD ingot over conventional ingots are discussed in conclusion

  12. Design of a steam generator for PWR power plants and steady state simulation

    International Nuclear Information System (INIS)

    Ferreira, W.J.

    1982-01-01

    A procedure and a computer code for the thermal design of a steam generator for PWR power plants is developed. A vertical integral steam generator with inverted U-tubes and natural circulation of the secondary side is selected for modelling. Primary fluid velocity and recirculation ratio are varied to obtain the preliminary dimensions. Further, adjustments are made through iteractive solution of the equations of conservation of mass, energy and momentum. An agreement is found between design calculations for steam generators of different capacities and existing designs. (Author) [pt

  13. Transport of lead in secondary systems of PWR plants: laboratory and plant investigations

    International Nuclear Information System (INIS)

    Feron, D.; Rocher, A.; Nordmann, F.

    1992-01-01

    Both in France and abroad, abnormally high lead concentrations have been found in the deposits on certain steam generator tubes subject to combined inter and transgranular corrosion on the secondary side. Many potential sources of lead have been identified in PWR steam-water system, mainly at the turbine level. Tests on a loop (ORION) have shown that lead (as Pb or PbO) can transport from the condenser to the steam generator and that the contaminant mainly concentrates in flow restricted areas of steam generators

  14. Analysis of transient heat conduction in a PWR fuel rod by an improved lumped parameter approach

    Energy Technology Data Exchange (ETDEWEB)

    Dourado, Eneida Regina G. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Cotta, Renato M. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Mecanica; Jian, Su, E-mail: eneidadourado@gmail.com, E-mail: sujian@nuclear.ufrj.br, E-mail: cotta@mecanica.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    This paper aims to analyze transient heat conduction in a nuclear fuel rod by an improved lumped parameter approach. One-dimensional transient heat conduction is considered, with the circumferential symmetry assumed and the axial conduction neglected. The thermal conductivity and specific heat in the fuel pellet are considered temperature dependent, while the thermophysical properties of the cladding are considered constant. Hermite approximation for integration is used to obtain the average temperature and heat flux in the radial direction. Significant improvement over the classical lumped parameter formulation has been achieved. The proposed model can be also used in dynamic analysis of PWR and nuclear power plant simulators. (author)

  15. Critical heat flux correlation analysis for PWR reactors with low mass flow

    International Nuclear Information System (INIS)

    Carajilescov, Pedro

    1996-01-01

    The major limit in the thermalhydraulic design of water cooled reactors consists in the occurrence of critical heat flux, which is verified by correlation of large range of validity. In the present work, the major design correlations were analyzed, through comparisons with experimental data, for utilization in PWR with low mass flux in the core. The results show that the EPRI correlation, with modifications, gives conservative results, from the safety point of view, with lower data spreading, being the most indicated for the reactor thermal design. (author)

  16. Re-irradiation and limit testing of the fuels PWR type reactors

    International Nuclear Information System (INIS)

    Roche, M.; Molvault, M.

    1978-01-01

    In view of investigating the neutron radiation behavior of PWR fuel pins, the S.P.S. (Services des Piles de Saclay) developed a set of experimental means used at OSIRIS in Saclay Nuclear Research Center. Said devices are shown to be able to meet present problems concerning can failures, power and temperature cycling, remote-control studies. These means can also be used either for statistical studies, they can then receive several samples, or for analytical studies in instrumented devices of large capacity and accelerated irradiation rate [fr

  17. Effects of Lower Drying-Storage Temperature on the Ductility of High-Burnup PWR Cladding

    Energy Technology Data Exchange (ETDEWEB)

    Billone, M. C. [Argonne National Lab. (ANL), Argonne, IL (United States); Burtseva, T. A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-08-30

    The purpose of this research effort is to determine the effects of canister and/or cask drying and storage on radial hydride precipitation in, and potential embrittlement of, high-burnup (HBU) pressurized water reactor (PWR) cladding alloys during cooling for a range of peak drying-storage temperatures (PCT) and hoop stresses. Extensive precipitation of radial hydrides could lower the failure hoop stresses and strains, relative to limits established for as-irradiated cladding from discharged fuel rods stored in pools, at temperatures below the ductile-to-brittle transition temperature (DBTT).

  18. SARDAN- A program for the transients simulation in a typical PWR plant

    International Nuclear Information System (INIS)

    Mattos Santos, R.L.P. de.

    1979-10-01

    A program in FORTRAN-IV language was developed that simulates the behaviour of the primary circuit in a typical PWR plant during condition II transients, in particular uncontrolled withdrawal of a control rod set, control rod set drops and uncontrolled boron dilution. It the mathematical model adopted the reactor core, the hot piping to which a pressurizer is coupled, the steam generator and the cold piping are considered. The results obtained in the analysis of the mentioned accidents are compared to those present at the Final Safety Analysis Report (FSAR) of the Angra-1 reactor and are considered satisfactory. (F.E.) [pt

  19. Flow with boiling in four-cusp channels simulating damaged core in PWR type reactors

    International Nuclear Information System (INIS)

    Esteves, M.M.

    1985-01-01

    The study of subcooled nucleate flow boiling in non-circular channels is of great importance to engineering applications in particular to Nuclear Engineering. In the present work, an experimental apparatus, consisting basically of a refrigeration system, running on refrigerant-12, has been developed. Preliminary tests were made with a circular tube. The main objective has been to analyse subcooled flow boiling in four-cusp channels simulating the flow conditions in a PWR core degraded by accident. Correlations were developed for the forced convection film coefficient for both single-phase and subcooled flow boiling. The incipience of boiling in such geometry has also been studied. (author) [pt

  20. Seismic analysis of the reactor coolant system of PWR nuclear power plants

    International Nuclear Information System (INIS)

    Borsoi, L.; Sollogoub, P.

    1986-01-01

    For safety considerations, seismic analyses are performed of the Reactor Coolant System (R.C.S.) of PWR Plants. After a brief description of the R.C.S. and R.C.S. operation, the paper presents the two types of analysis used to determine the effect of earthquake on the R.C.S.: modal spectral analysis and nonlinear time history analysis. The paper finally shows how seismic loadings are combined with other types of loadings and illustrates how the consideration of seismic loads affects R.C.S. design [fr