WorldWideScience

Sample records for standard 1d-lte spectroscopic

  1. Standards development for fiber optic spectroscopic components for adverse environments

    Science.gov (United States)

    Saggese, Steven J.; Greenwell, Roger A.

    1994-09-01

    Optical fiber sensors are finding wider use in all types of applications involving adverse environments, including exposure to radiation. In order to effectively characterize and evaluate the performance of a fiber sensor system for a radiation environment, such as within a nuclear power plant or in a radioactive waste storage/disposal facility, it is beneficial to develop standard test procedures. Science & Engineering Associates (SEA) has developed two such procedures for the American Society for Testing and Materials (ASTM) which address the testing of optical fibers for remote Raman spectroscopic and broadband sensor applications in a steady state radiation environment.

  2. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  3. Spectroscopic characterization of a Nigerian standard sand: Igbokoda sand

    CSIR Research Space (South Africa)

    Ojuri, OO

    2017-01-01

    Full Text Available The characterization of the Nigerian Igbokoda Standard Sand was performed by X-ray diffraction, IR and Raman Spectroscopy, and nuclear magnetic resonance techniques. The principal reflections occurring at the d-Spacings of 4.25745, 3.34359, 2...

  4. Spectroscopic metrology for isotope composition measurements and transfer standards

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Balslev-Harder, David; Kääriäinen, Teemu; Richmond, Craig; Manninen, Albert; Mohn, Joachim; Kiseleva, Maria; Petersen, Jan C.; Werhahn, Olav; Ebert, Volker

    2017-04-01

    The World Meteorological Organization (WMO) has identified greenhouse gases such as CO2, CH4 and N2O as critical for global climate monitoring. Other molecules such as CO that has an indirect effect of enhancing global warming are also monitored. WMO has stated compatibility goals for atmospheric concentration and isotope ratio measurements of these gases, e.g. 0.1 ppm for CO2 concentration measurements in the northern hemisphere and 0.01 ‰ for δ13C-CO2. For measurements of the concentration of greenhouse gases, gas analysers are typically calibrated with static gas standards e.g. traceable to the WMO scale or to the International System of Units (SI) through a national metrology institute. However, concentrations of target components, e.g. CO, in static gas standards have been observed to drift, and typically the gas matrix as well as the isotopic composition of the target component does not always reflect field gas composition, leading to deviations of the analyser response, even after calibration. The deviations are dependent on the measurement technique. To address this issue, part of the HIGHGAS (Metrology for high-impact greenhouse gases) project [1] focused on the development of optical transfer standards (OTSs) for greenhouse gases, e.g. CO2 and CO, potentially complementing gas standards. Isotope ratio mass spectrometry (IRMS) [2] is currently used to provide state-of-the-art high precision (in the 0.01 ‰ range) measurements for the isotopic composition of greenhouse gases. However, there is a need for field-deployable techniques such as optical isotope ratio spectroscopy (OIRS) that can be combined with metrological measurement methods. Within the HIGHGAS project, OIRS methods and procedures based on e.g. cavity enhanced spectroscopy (CES) and tunable diode laser absorption spectroscopy (TDLAS), matched to metrological principles have been established for the measurement of 13C/12C and 18O/16O ratios in CO2, 15N/14N ratios in N2O, and 13C/12C and 2H

  5. Spectroscopic data

    CERN Document Server

    Melzer, J

    1976-01-01

    During the preparation of this compilation, many people contributed; the compilers wish to thank all of them. In particular they appreciate the efforts of V. Gilbertson, the manuscript typist, and those of K. C. Bregand, J. A. Kiley, and W. H. McPherson, who gave editorial assistance. They would like to thank Dr. J. R. Schwartz for his cooperation and encouragement. In addition, they extend their grati­ tude to Dr. L. Wilson of the Air Force Weapons Laboratory, who gave the initial impetus to this project. v Contents I. I ntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . 11. Organization ofthe Spectroscopic Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Methods of Production and Experimental Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Band Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2...

  6. Spectroscopic study

    International Nuclear Information System (INIS)

    Flores, M.; Rodriguez, R.; Arroyo, R.

    1999-01-01

    This work is focused about the spectroscopic properties of a polymer material which consists of Polyacrylic acid (Paa) doped at different concentrations of Europium ions (Eu 3+ ). They show that to stay chemically joined with the polymer by a study of Nuclear Magnetic Resonance (NMR) of 1 H, 13 C and Fourier Transform Infrared Spectroscopy (Ft-IR) they present changes in the intensity of signals, just as too when this material is irradiated at λ = 394 nm. In according with the results obtained experimentally in this type of materials it can say that is possible to unify chemically the polymer with this type of cations, as well as, varying the concentration of them, since that these are distributed homogeneously inside the matrix maintaining its optical properties. These materials can be obtained more quickly and easy in solid or liquid phase and they have the best conditions for to make a quantitative analysis. (Author)

  7. Spectroscopic analysis of optoelectronic semiconductors

    CERN Document Server

    Jimenez, Juan

    2016-01-01

    This book deals with standard spectroscopic techniques which can be used to analyze semiconductor samples or devices, in both, bulk, micrometer and submicrometer scale. The book aims helping experimental physicists and engineers to choose the right analytical spectroscopic technique in order to get specific information about their specific demands. For this purpose, the techniques including technical details such as apparatus and probed sample region are described. More important, also the expected outcome from experiments is provided. This involves also the link to theory, that is not subject of this book, and the link to current experimental results in the literature which are presented in a review-like style. Many special spectroscopic techniques are introduced and their relationship to the standard techniques is revealed. Thus the book works also as a type of guide or reference book for people researching in optical spectroscopy of semiconductors.

  8. Validation of spectroscopic gas analyzer accuracy using gravimetric standard gas mixtures: impact of background gas composition on CO2 quantitation by cavity ring-down spectroscopy

    Directory of Open Access Journals (Sweden)

    J. S. Lim

    2017-12-01

    Full Text Available The effect of background gas composition on the measurement of CO2 levels was investigated by wavelength-scanned cavity ring-down spectrometry (WS-CRDS employing a spectral line centered at the R(1 of the (3 00 1III  ←  (0 0 0 band. For this purpose, eight cylinders with various gas compositions were gravimetrically and volumetrically prepared within 2σ = 0.1 %, and these gas mixtures were introduced into the WS-CRDS analyzer calibrated against standards of ambient air composition. Depending on the gas composition, deviations between CRDS-determined and gravimetrically (or volumetrically assigned CO2 concentrations ranged from −9.77 to 5.36 µmol mol−1, e.g., excess N2 exhibited a negative deviation, whereas excess Ar showed a positive one. The total pressure broadening coefficients (TPBCs obtained from the composition of N2, O2, and Ar thoroughly corrected the deviations up to −0.5 to 0.6 µmol mol−1, while these values were −0.43 to 1.43 µmol mol−1 considering PBCs induced by only N2. The use of TPBC enhanced deviations to be corrected to ∼ 0.15 %. Furthermore, the above correction linearly shifted CRDS responses for a large extent of TPBCs ranging from 0.065 to 0.081 cm−1 atm−1. Thus, accurate measurements using optical intensity-based techniques such as WS-CRDS require TPBC-based instrument calibration or use standards prepared in the same background composition of ambient air.

  9. Validation of spectroscopic gas analyzer accuracy using gravimetric standard gas mixtures: impact of background gas composition on CO2 quantitation by cavity ring-down spectroscopy

    Science.gov (United States)

    Lim, Jeong Sik; Park, Miyeon; Lee, Jinbok; Lee, Jeongsoon

    2017-12-01

    The effect of background gas composition on the measurement of CO2 levels was investigated by wavelength-scanned cavity ring-down spectrometry (WS-CRDS) employing a spectral line centered at the R(1) of the (3 00 1)III ← (0 0 0) band. For this purpose, eight cylinders with various gas compositions were gravimetrically and volumetrically prepared within 2σ = 0.1 %, and these gas mixtures were introduced into the WS-CRDS analyzer calibrated against standards of ambient air composition. Depending on the gas composition, deviations between CRDS-determined and gravimetrically (or volumetrically) assigned CO2 concentrations ranged from -9.77 to 5.36 µmol mol-1, e.g., excess N2 exhibited a negative deviation, whereas excess Ar showed a positive one. The total pressure broadening coefficients (TPBCs) obtained from the composition of N2, O2, and Ar thoroughly corrected the deviations up to -0.5 to 0.6 µmol mol-1, while these values were -0.43 to 1.43 µmol mol-1 considering PBCs induced by only N2. The use of TPBC enhanced deviations to be corrected to ˜ 0.15 %. Furthermore, the above correction linearly shifted CRDS responses for a large extent of TPBCs ranging from 0.065 to 0.081 cm-1 atm-1. Thus, accurate measurements using optical intensity-based techniques such as WS-CRDS require TPBC-based instrument calibration or use standards prepared in the same background composition of ambient air.

  10. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  11. Spectroscopic analysis and control

    Energy Technology Data Exchange (ETDEWEB)

    Tate; , James D.; Reed, Christopher J.; Domke, Christopher H.; Le, Linh; Seasholtz, Mary Beth; Weber, Andy; Lipp, Charles

    2017-04-18

    Apparatus for spectroscopic analysis which includes a tunable diode laser spectrometer having a digital output signal and a digital computer for receiving the digital output signal from the spectrometer, the digital computer programmed to process the digital output signal using a multivariate regression algorithm. In addition, a spectroscopic method of analysis using such apparatus. Finally, a method for controlling an ethylene cracker hydrogenator.

  12. Spectroscopic Dosimeter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Analysis of Phase I test data demonstrates that the Photogenics Spectroscopic Dosimeter will detect neutron energies from 0.8 up to 600 MeV. The detector...

  13. Spectroscopically Unlocking Exoplanet Characteristics

    Science.gov (United States)

    Lewis, Nikole

    2016-05-01

    Spectroscopy plays a critical role in a number of areas of exoplanet research. The first exoplanets were detected by precisely measuring Doppler shifts in high resolution (R ~ 100,000) stellar spectra, a technique that has become known as the Radial Velocity (RV) method. The RV method provides critical constraints on exoplanet masses, but is currently limited to some degree by robust line shape predictions. Beyond the RV method, spectroscopy plays a critical role in the characterization of exoplanets beyond their mass and radius. The Hubble Space Telescope has spectroscopically observed the atmospheres of exoplanets that transit their host stars as seen from Earth giving us key insights into atmospheric abundances of key atomic and molecular species as well as cloud optical properties. Similar spectroscopic characterization of exoplanet atmospheres will be carried out at higher resolution (R ~ 100-3000) and with broader wavelength coverage with the James Webb Space Telescope. Future missions such as WFIRST that seek to the pave the way toward the detection and characterization of potentially habitable planets will have the capability of directly measuring the spectra of exoplanet atmospheres and potentially surfaces. Our ability to plan for and interpret spectra from exoplanets relies heavily on the fidelity of the spectroscopic databases available and would greatly benefit from further laboratory and theoretical work aimed at optical properties of atomic, molecular, and cloud/haze species in the pressure and temperature regimes relevant to exoplanet atmospheres.

  14. Integrated photonics for infrared spectroscopic sensing

    Science.gov (United States)

    Lin, Hongtao; Kita, Derek; Han, Zhaohong; Su, Peter; Agarwal, Anu; Yadav, Anupama; Richardson, Kathleen; Gu, Tian; Hu, Juejun

    2017-05-01

    Infrared (IR) spectroscopy is widely recognized as a gold standard technique for chemical analysis. Traditional IR spectroscopy relies on fragile bench-top instruments located in dedicated laboratory settings, and is thus not suitable for emerging field-deployed applications such as in-line industrial process control, environmental monitoring, and point-ofcare diagnosis. Recent strides in photonic integration technologies provide a promising route towards enabling miniaturized, rugged platforms for IR spectroscopic analysis. Chalcogenide glasses, the amorphous compounds containing S, Se or Te, have stand out as a promising material for infrared photonic integration given their broadband infrared transparency and compatibility with silicon photonic integration. In this paper, we discuss our recent work exploring integrated chalcogenide glass based photonic devices for IR spectroscopic chemical analysis, including on-chip cavityenhanced chemical sensing and monolithic integration of mid-IR waveguides with photodetectors.

  15. SYNTHESES, SPECTROSCOPIC AND MAGNETIC PROPERTIES ...

    African Journals Online (AJOL)

    Preferred Customer

    SYNTHESES, SPECTROSCOPIC AND MAGNETIC PROPERTIES OF. POLYSTYRENE-ANCHORED COORDINATION COMPOUNDS OF. THIAZOLIDINONE. Dinesh Kumar1, Amit Kumar2* and Durga Dass3. 1Department of Chemistry, National Institute of Technology, Kurukshetra 136119, Haryana,. India. 2Department of ...

  16. Spectroscopic Classification of Two Supernovae

    Science.gov (United States)

    Gomez, S.; Blanchard, P.; Nicholl, M.; Berger, E.

    2018-02-01

    We obtained optical spectroscopic observations of 2 transients reported to the Transient Name Server by the ATLAS survey (Tonry et al. 2011, PASP, 123, 58; Tonry et al., ATel #8680) and the Pan-STARRS Survey for Transients (PSST; Huber et al., ATel #7153; http://star.pst.qub.ac.uk/ps1threepi/).

  17. Universal relation between spectroscopic constants

    Indian Academy of Sciences (India)

    (3) The author has used eq. (6) of his paper to calculate De. This relation leads to a large deviation from the correct value depending upon the extent to which experimental values are known. Guided by this fact, in our work, we used experimentally observed De values to derive the relation between spectroscopic constants.

  18. A multiple-detector Radioactive Material Detection Spectroscopic (RMDS) portal

    International Nuclear Information System (INIS)

    Yaar, Ilan; Peysakhov, Ilya

    2013-01-01

    This paper describes an optimization process for a Radioactive Material Detection Spectroscopic (RMDS) portal, designed to detect and identify radioactive materials concealed inside cargo containers. The system is based on a combination of conventional 3 in. NaI(Tl) gamma detectors and 3 He neutron detection tubes. The basic concept and the advantages of the new segmented spectroscopic detector approach are presented with several algorithms that were developed to enhance the detection capability of the portal and improve the signal to noise ratio. The results of field tests performed in several locations in Israel are also presented. The RMDS portal fully meets the demands of new ANSI Standard 42.38 for spectroscopic portals. In addition, the portal has some unique features, such as the ability to find the exact location of a point source inside the cargo and the ability to differentiate between a point source and Naturally Occurring Radioactive Materials (NORM) radiation. During the tests, the RMDS portal was compared to other detection systems, such as a PVT-based portal and a handheld spectroscopic HPGe detector. In these tests, the RMDS system was found to have a unique technique for background subtraction, which results in a higher detection sensitivity

  19. A multiple-detector Radioactive Material Detection Spectroscopic (RMDS) portal

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, Ilan, E-mail: iyaar@nrcn.org.il [Nuclear Research Center Negev (NRCN), P.O. Box 9001, Beer-Sheva 84190 (Israel); Peysakhov, Ilya [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2013-06-01

    This paper describes an optimization process for a Radioactive Material Detection Spectroscopic (RMDS) portal, designed to detect and identify radioactive materials concealed inside cargo containers. The system is based on a combination of conventional 3 in. NaI(Tl) gamma detectors and {sup 3}He neutron detection tubes. The basic concept and the advantages of the new segmented spectroscopic detector approach are presented with several algorithms that were developed to enhance the detection capability of the portal and improve the signal to noise ratio. The results of field tests performed in several locations in Israel are also presented. The RMDS portal fully meets the demands of new ANSI Standard 42.38 for spectroscopic portals. In addition, the portal has some unique features, such as the ability to find the exact location of a point source inside the cargo and the ability to differentiate between a point source and Naturally Occurring Radioactive Materials (NORM) radiation. During the tests, the RMDS portal was compared to other detection systems, such as a PVT-based portal and a handheld spectroscopic HPGe detector. In these tests, the RMDS system was found to have a unique technique for background subtraction, which results in a higher detection sensitivity.

  20. Spectroscopic Classification of Seven Supernovae

    Science.gov (United States)

    Blanchard, P.; Gomez, S.; Nicholl, M.; Berger, E.

    2018-01-01

    We obtained optical spectroscopic observations of 7 transients reported to the Transient Name Server by the ATLAS survey (Tonry et al. 2011, PASP, 123, 58; Tonry et al., ATel #8680), the Pan-STARRS Survey for Transients (PSST; Huber et al., ATel #7153; http://star.pst.qub.ac.uk/ps1threepi/), DPAC and the ESA Gaia Photometric Science Alerts Team (http://gsaweb.ast.cam.ac.uk/alerts), and the Tsinghua University-National Astronomical Observatories of China Transient Survey (TNTS).

  1. Mid-infrared spectroscopic investigation

    International Nuclear Information System (INIS)

    Walter, L.; Vergo, N.; Salisbury, J.W.

    1987-01-01

    Mid-infrared spectroscopic research efforts are discussed. The development of a new instrumentation to permit advanced measurements in the mid-infrared region of the spectrum, the development of a special library of well-characterized mineral and rock specimens for interpretation of remote sensing data, and cooperative measurements of the spectral signatures of analogues of materials that may be present on the surfaces of asteroids, planets or their Moons are discussed

  2. Single nanoparticle tracking spectroscopic microscope

    Science.gov (United States)

    Yang, Haw [Moraga, CA; Cang, Hu [Berkeley, CA; Xu, Cangshan [Berkeley, CA; Wong, Chung M [San Gabriel, CA

    2011-07-19

    A system that can maintain and track the position of a single nanoparticle in three dimensions for a prolonged period has been disclosed. The system allows for continuously imaging the particle to observe any interactions it may have. The system also enables the acquisition of real-time sequential spectroscopic information from the particle. The apparatus holds great promise in performing single molecule spectroscopy and imaging on a non-stationary target.

  3. Multi-pass spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Stehle, Jean-Louis; Samartzis, Peter C.; Stamataki, Katerina; Piel, Jean-Philippe; Katsoprinakis, George E.; Papadakis, Vassilis; Schimowski, Xavier; Rakitzis, T. Peter; Loppinet, Benoit

    2014-01-01

    Spectroscopic ellipsometry is an established technique, particularly useful for thickness measurements of thin films. It measures polarization rotation after a single reflection of a beam of light on the measured substrate at a given incidence angle. In this paper, we report the development of multi-pass spectroscopic ellipsometry where the light beam reflects multiple times on the sample. We have investigated both theoretically and experimentally the effect of sample reflectivity, number of reflections (passes), angles of incidence and detector dynamic range on ellipsometric observables tanΨ and cosΔ. The multiple pass approach provides increased sensitivity to small changes in Ψ and Δ, opening the way for single measurement determination of optical thickness T, refractive index n and absorption coefficient k of thin films, a significant improvement over the existing techniques. Based on our results, we discuss the strengths, the weaknesses and possible applications of this technique. - Highlights: • We present multi-pass spectroscopic ellipsometry (MPSE), a multi-pass approach to ellipsometry. • Different detectors, samples, angles of incidence and number of passes were tested. • N passes improve polarization ratio sensitivity to the power of N. • N reflections improve phase shift sensitivity by a factor of N. • MPSE can significantly improve thickness measurements in thin films

  4. Spectroscopic amplifier for pin diode

    International Nuclear Information System (INIS)

    Alonso M, M. S.; Hernandez D, V. M.; Vega C, H. R.

    2014-10-01

    The photodiode remains the basic choice for the photo-detection and is widely used in optical communications, medical diagnostics and field of corpuscular radiation. In detecting radiation it has been used for monitoring radon and its progeny and inexpensive spectrometric systems. The development of a spectroscopic amplifier for Pin diode is presented which has the following characteristics: canceler Pole-Zero (P/Z) with a time constant of 8 μs; constant gain of 57, suitable for the acquisition system; 4th integrator Gaussian order to waveform change of exponential input to semi-Gaussian output and finally a stage of baseline restorer which prevents Dc signal contribution to the next stage. The operational amplifier used is the TLE2074 of BiFET technology of Texas Instruments with 10 MHz bandwidth, 25 V/μs of slew rate and a noise floor of 17 nv/(Hz)1/2. The integrated circuit has 4 operational amplifiers and in is contained the total of spectroscopic amplifier that is the goal of electronic design. The results show like the exponential input signal is converted to semi-Gaussian, modifying only the amplitude according to the specifications in the design. The total system is formed by the detector, which is the Pin diode, a sensitive preamplifier to the load, the spectroscopic amplifier that is what is presented and finally a pulse height analyzer (Mca) which is where the spectrum is shown. (Author)

  5. Mossbauer spectroscopic studies in ferroboron

    Science.gov (United States)

    Yadav, Ravi Kumar; Govindaraj, R.; Amarendra, G.

    2017-05-01

    Mossbauer spectroscopic studies have been carried out in a detailed manner on ferroboron in order to understand the local structure and magnetic properties of the system. Evolution of the local structure and magnetic properties of the amorphous and crystalline phases and their thermal stability have been addressed in a detailed manner in this study. Role of bonding between Fe 4s and/or 4p electrons with valence electrons of boron (2s,2p) in influencing the stability and magnetic properties of Fe-B system is elucidated.

  6. Proxy magnetometry of the photosphere: why are G-band bright points so bright?

    NARCIS (Netherlands)

    Rutten, R.J.; Kiselman, Dan; Voort, Luc Rouppe van der; Plez, Bertrand

    2000-01-01

    We discuss the formation of G-band bright points in terms of standard uxtube modeling, in particular the 1D LTE models constructed by Solanki and coworkers. Combined with LTE spectral synthesis they explain observed G-band bright point contrasts quite well. The G-band contrast increase over the

  7. Spectroscopic temperature measurements of non-equilibrium plasmas

    International Nuclear Information System (INIS)

    Back, C.A.; Glenzer, S.H.; Lee, R.W.; MacGowan, B.J.

    1996-01-01

    The characterization of laser-produced plasmas has required the application of spectroscopic techniques to non-standard conditions where kinetics models have not been extensively tested. The plasmas are produced by the Nova laser for the study of inertial confinement fusion, can be mm in size, and evolve on sub-nanosecond time scales. These targets typically achieve electron temperatures from 2-4 keV and electron densities of 10 20 -10 22 cm -3 . The authors have measured the electron temperature of two types of targets: bags of gas and hohlraums, Au cylinders with laser entrance holes in the flat ends. By comparing data from different targets, they examine the time-dependence of spectroscopic plasma diagnostics

  8. Cosmic homogeneity: a spectroscopic and model-independent measurement

    Science.gov (United States)

    Gonçalves, R. S.; Carvalho, G. C.; Bengaly, C. A. P., Jr.; Carvalho, J. C.; Bernui, A.; Alcaniz, J. S.; Maartens, R.

    2018-03-01

    Cosmology relies on the Cosmological Principle, i.e. the hypothesis that the Universe is homogeneous and isotropic on large scales. This implies in particular that the counts of galaxies should approach a homogeneous scaling with volume at sufficiently large scales. Testing homogeneity is crucial to obtain a correct interpretation of the physical assumptions underlying the current cosmic acceleration and structure formation of the Universe. In this letter, we use the Baryon Oscillation Spectroscopic Survey to make the first spectroscopic and model-independent measurements of the angular homogeneity scale θh. Applying four statistical estimators, we show that the angular distribution of galaxies in the range 0.46 Universe in the past. These results are in agreement with the foundations of the standard cosmological paradigm.

  9. Spectroscopic data bank of nuclear quadrupole resonance

    International Nuclear Information System (INIS)

    Grechishkin, V.S.; Grechishkina, R.V.

    1997-01-01

    Capabilities of a special spectroscopic database application program are described. The work conducted has demonstrated the efficiency of the Microsoft Office package for control of spectroscopic databases and analysis of technological mixtures in a field of radio spectroscopy like nuclear quadrupole resonance

  10. Synthesis and spectroscopic properties of homo- and ...

    Indian Academy of Sciences (India)

    Unknown

    Mehrotra. Synthesis and spectroscopic properties of homo- and heterobimetallic complexes of oxovanadium(V). † ... Spectroscopic (IR, UV–Vis and (1H, 27Al, 51V) NMR) properties of the new com- plexes have been investigated and their ... refluxed under a fractionating column (10 cm), fol- lowed by continuous azeotropic ...

  11. Statistical properties of spectroscopic binary stars

    NARCIS (Netherlands)

    Hogeveen, S.J.

    1992-01-01

    As part of a study of the mass-ratio distribution of spectroscopic binary stars, the statistical properties of the systems in the Eighth Catalogue of the Orbital Elements of Spectroscopic Binary Stars, compiled by Batten et al. (1989), are investigated. Histograms are presented of the

  12. Raman Spectroscopic Studies of Methane Gas Hydrates

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.

    2009-01-01

    A brief review of the Raman spectroscopic studies of methane gas hydrates is given, supported by some new measurements done in our laboratory.......A brief review of the Raman spectroscopic studies of methane gas hydrates is given, supported by some new measurements done in our laboratory....

  13. Synthesis, molecular structure, spectroscopic investigations and ...

    Indian Academy of Sciences (India)

    The spectroscopic properties of the title compound have beeninvestigated by using IR, UV–Vis and ¹H NMR techniques. The molecular geometry and spectroscopic data of the title compound have been calculated by using the density functional method (B3LYP) invoking 6-311G(d,p) basis set. UV-Vis spectra of the two ...

  14. Spectroscopic investigations of crude oil and petroleum products in combination with chemometric methods

    International Nuclear Information System (INIS)

    Tuechler, W.

    1997-11-01

    In the present work, chemometric methods were used for investigations of crude oils and petroleum products by statistical evaluation of spectroscopic data. The spectroscopic information was obtained by 1 H-Nuclear Magnetic Resonance and infrared experiments. Research octane numbers (RON) and motor octane numbers (MON), representing important characteristics for knocking behavior,were calculated by multilinear regression. In the period of two years it was tested whether the precision of such models was negatively influenced by varying chemical composition of the commercial gasoline. A Partial Least Squares model (PLS) was created to calculate MON. The model based on infrared spectroscopic data in the spectral region of 1400 to 650 cm 1 . The standard deviation between PLS-method and the standard method ASTM D 2700 was 0,6. Another PLS-model in combination with spectroscopic data was used for calculating cetane numbers of diesel fuels. Using the spectral region of 1650 to 650 cm 1 the content of the cetane improver 2-ethyl-hexyl-nitrate could be detected. A standard deviation of 1,8 to ASTM D 613 has been achieved. An additional aim of the work was to identify crude oils by the means of principal component analysis of spectroscopic data in the near infrared region. The investigations included the determination of negative effects on data acquisition like varying temperature, water-, salt-, and sediment content. Furthermore, the density and the boiling yields in distillation of crude oils were calculated with PLS-models. (author)

  15. Does DFT-SAPT method provide spectroscopic accuracy?

    Energy Technology Data Exchange (ETDEWEB)

    Shirkov, Leonid; Makarewicz, Jan, E-mail: jama@amu.edu.pl [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89b, 61-614 Poznań (Poland)

    2015-02-14

    Ground state potential energy curves for homonuclear and heteronuclear dimers consisting of noble gas atoms from He to Kr were calculated within the symmetry adapted perturbation theory based on the density functional theory (DFT-SAPT). These potentials together with spectroscopic data derived from them were compared to previous high-precision coupled cluster with singles and doubles including the connected triples theory calculations (or better if available) as well as to experimental data used as the benchmark. The impact of midbond functions on DFT-SAPT results was tested to study the convergence of the interaction energies. It was shown that, for most of the complexes, DFT-SAPT potential calculated at the complete basis set (CBS) limit is lower than the corresponding benchmark potential in the region near its minimum and hence, spectroscopic accuracy cannot be achieved. The influence of the residual term δ(HF) on the interaction energy was also studied. As a result, we have found that this term improves the agreement with the benchmark in the repulsive region for the dimers considered, but leads to even larger overestimation of potential depth D{sub e}. Although the standard hybrid exchange-correlation (xc) functionals with asymptotic correction within the second order DFT-SAPT do not provide the spectroscopic accuracy at the CBS limit, it is possible to adjust empirically basis sets yielding highly accurate results.

  16. Spectroscopic and asteroseismic analysis of the remarkable main-sequence A star KIC 11145123

    DEFF Research Database (Denmark)

    Takada-Hidai, Masahide; Kurtz, Donald W.; Shibahashi, Hiromoto

    2017-01-01

    -eff = 7600 K, log g = 4.2, xi = 3.1 kms(-1) and [Fe/H] = -0.71 dex), the radial and rotation velocities, and elemental abundances were obtained by analysing line strengths and fitting line profiles, which were calculated with a 1D LTE model atmosphere. The main properties of KIC 11145123 are: (1) a low [Fe....../H] = -0.71 +/- 0.11 dex and a high radial velocity of -135.4 +/- 0.2 km s(-1). These are remarkable among late-A stars. Our best asteroseismic models with this low [Fe/H] have slightly high helium abundance and low masses of 1.4 M-circle dot. All of these results strongly suggest that KIC 11145123...... is a Population II blue straggler; (2) the projected rotation velocity confirms the asteroseismically predicted slow rotation of the star; (3) comparisons of abundance patterns between KIC 11145123 and Am, Ap, and blue stragglers show that KIC 11145123 is neither an Am star nor an Ap star, but has abundances...

  17. Synthesis, Spectroscopic and Pharmacological Studies of Bivalent ...

    African Journals Online (AJOL)

    Synthesis, Spectroscopic and Pharmacological Studies of Bivalent Copper, Zinc and Mercury Complexes of Thiourea. ... All the metal complexes were characterized by elemental chemical analysis, molar conductance, magnetic susceptibility measurements and IR spectroscopy. Cu(II) complexes were additionally ...

  18. Vibrational Spectroscopic Techniques for Probing Bioelectrochemical Systems.

    Science.gov (United States)

    Ash, Philip A; Vincent, Kylie A

    A more complete understanding of bioelectrochemical interfaces is of increasing importance in both fundamental studies and biotechnological applications of proteins. Bioelectrochemical methods provide detailed information about the activity or rate of a process, but in situ spectroscopic methods are needed to gain direct structural insight into functionally relevant states. A number of methods have been reported that allow electrochemical and spectroscopic data to be collected from the same electrode, providing direct spectroscopic 'snapshots' of protein function, and here we focus on the application of infrared and Raman spectroscopies to the study of electrode-immobilised species. The ability to probe coordination at metal centres, protonation changes in amino acid side chains, reaction-induced changes in organic cofactors or substrates, protein orientation and subtle changes in protein secondary structure simultaneously, rapidly and at room temperature means that vibrational spectroscopic approaches are almost uniquely applicable to answering a wide range of questions in bioelectrochemistry.

  19. Atomic Data for Fusion: Volume 6, Spectroscopic data for titanium, chromium, and nickel

    Energy Technology Data Exchange (ETDEWEB)

    Wiese, W.L.; Musgrove, A. (eds.) (National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1989-09-01

    Comprehensive spectroscopic data tables are presented for all ionization stages of chromium. Tables of ionization potentials, spectral lines, energy levels, and transition probabilities are presented. These tables contain data which have been excerpted from general critical compilations prepared under the sponsorship of the National Standard Reference Data System (NSRDS).

  20. Atomic Data for Fusion: Volume 6, Spectroscopic data for titanium, chromium, and nickel

    International Nuclear Information System (INIS)

    Wiese, W.L.; Musgrove, A.

    1989-09-01

    Comprehensive spectroscopic data tables are presented for all ionization stages of chromium. Tables of ionization potentials, spectral lines, energy levels, and transition probabilities are presented. These tables contain data which have been excerpted from general critical compilations prepared under the sponsorship of the National Standard Reference Data System (NSRDS)

  1. The stability of spectroscopic instruments : a unified Allan variance computation scheme

    NARCIS (Netherlands)

    Ossenkopf, V.

    Context. The Allan variance is a standard technique to characterise the stability of spectroscopic instruments used in astronomical observations. The period for switching between source and reference measurement is often derived from the Allan minimum time. However, various methods are applied to

  2. Spectroscopic diagnostics of industrial plasmas

    International Nuclear Information System (INIS)

    Joshi, N.K.

    2004-01-01

    Plasmas play key role in modern industry and are being used for processing micro electronic circuits to the destruction of toxic waste. Characterization of industrial plasmas which includes both 'thermal plasmas' and non-equilibrium plasmas or 'cold plasmas' in industrial environment offers quite a challenge. Numerous diagnostic techniques have been developed for the measurement of these partially ionized plasma and/or particulate parameters. The 'simple' non-invasive spectroscopic methods for characterization of industrial plasmas will be discussed in detail in this paper. The excitation temperature in thermal (DC/RF) plasma jets has been determined using atomic Boltzmann technique. The central axis temperature of thermal plasma jets in a spray torch can be determined using modified atomic Boltzmann technique with out using Abel inversion. The Stark broadening of H β and Ar-I (430 nm) lines have been used to determine the electron number density in thermal plasma jets. In low-pressure non-equilibrium argon plasma, electron temperature has been measured using the Corona model from the ratio of line intensities of atomic and ionic transitions. (author)

  3. Spectroscopic investigation of protein corona

    Science.gov (United States)

    Choudhary, Poonam

    Nanotechnology has revolutionalized the landscape of modern science and technology, including materials, electronics, therapeutics, bioimaging, sensing, and the environment. Research in the past decade has examined the fate of nanomaterials in vitro and in vivo, as well as the interactions between nanoparticles and biological and ecosystems using primarily toxicological and ecotoxicological approaches. However, due to the versatility in the physical and physicochemical properties of nanoparticles, and due to the vast complexity of their hosting systems, the solubility, transformation, and biocompatibility of nanomaterials are still poorly understood. Nanotechnology has been undergoing tremendous development in recent decades, driven by realized perceived applications of nanomaterials in electronics, therapeutics, imaging, sensing, environmental remediation, and consumer products. Nanoparticles on entering the blood stream undergo an identity change, they become coated with proteins. There are different kind of proteins present in blood. Proteins compete for getting coated over the surface of nanoparticle and this whole entity of proteins coated over nanoparticle surface is called Protein Corona. Proteins tightly bound to the surface of nanoparticle form hard corona and the ones loosely bound on the outer surface form soft corona. This dissertation is aimed at spectroscopic investigation of Protein Corona. Chapter I of this dissertation offers a comprehensive review of the literature based on nanomaterials with the focus on carbon based nanomaterilas and introduction to Protein Corona. Chapter II is based different methods used for Graphene Synthesis,different types of defects and doping. In Chapter III influence of defects on Graphene Protein Corona was investigated. Chapter IV is based on the study of Apoptosis induced cell death by Gold and silver nanoparticles. In vitro study of effect of Protein Corona on toxicity of cells was done.

  4. Liver Steatosis: Concordance of MR Imaging and MR Spectroscopic Data with Histologic Grade

    Science.gov (United States)

    Lam, Maggie M.; Merriman, Raphael B.; Ferrell, Linda; Qayyum, Aliya

    2012-01-01

    Purpose: To determine if the concordance of magnetic resonance (MR) imaging and MR spectroscopic data with histologic measures of steatosis is affected by histologic magnification level, tissue heterogeneity, or assessment of tissue area versus that of hepatocytes. Materials and Methods: This study was institutional review board approved and HIPAA compliant. Written informed consent was obtained. In- and out-of-phase MR imaging and MR spectroscopic measures of steatosis were compared in 33 patients with nonalcoholic fatty liver disease and in 15 healthy volunteers. Concordance of MR imaging and MR spectroscopic data with histologic findings was assessed for (a) histologic examination at standard (×40 and ×100) versus high magnification (×200 and ×400), (b) heterogeneity and homogeneity of livers, and (c) percentage of tissue and hepatocytes that contained lipids. Evaluations included linear regression and Fisher exact tests. Results: In- and out-of-phase MR imaging and MR spectroscopic data were well correlated (R2 = 0.93) and generally concordant with histologic measures. Patients in whom MR fat fractions were higher than expected compared with steatosis grades at standard magnification histologic examination were upgraded significantly more often when high magnification was used than were the remaining patients (100% [10 of 10] vs 47% [7 of 15], P spectroscopic data of homogeneous livers were significantly more likely than those of heterogeneous livers to be concordant with steatosis grades when high magnification was used (81% [13 of 16] vs 47% [8 of 17], P spectroscopic data were generally concordant with histologic measures of steatosis. Discordance between them may reflect differences in magnification at histologic examination and in liver heterogeneity. © RSNA, 2012 PMID:22723561

  5. SICK: THE SPECTROSCOPIC INFERENCE CRANK

    International Nuclear Information System (INIS)

    Casey, Andrew R.

    2016-01-01

    There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal

  6. sick: The Spectroscopic Inference Crank

    Science.gov (United States)

    Casey, Andrew R.

    2016-03-01

    There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal

  7. Spectroscopic methods to analyze drug metabolites.

    Science.gov (United States)

    Yi, Jong-Jae; Park, Kyeongsoon; Kim, Won-Je; Rhee, Jin-Kyu; Son, Woo Sung

    2018-03-09

    Drug metabolites have been monitored with various types of newly developed techniques and/or combination of common analytical methods, which could provide a great deal of information on metabolite profiling. Because it is not easy to analyze whole drug metabolites qualitatively and quantitatively, a single solution of analytical techniques is combined in a multilateral manner to cover the widest range of drug metabolites. Mass-based spectroscopic analysis of drug metabolites has been expanded with the help of other parameter-based methods. The current development of metabolism studies through contemporary pharmaceutical research are reviewed with an overview on conventionally used spectroscopic methods. Several technical approaches for conducting drug metabolic profiling through spectroscopic methods are discussed in depth.

  8. Spectroscopic characteristics of spiral flow ICP for axially viewing ICP optical emission spectrometry.

    Science.gov (United States)

    Ohata, Masaki; Kurosawa, Satoru; Shinoduka, Isao; Takaku, Yuichi; Kishi, Yoko

    2015-01-01

    Spectroscopic characteristics of a spiral flow inductively coupled plasma (ICP), which could be sustained stably at 9 L min(-1) of Ar plasma gas flow rate with 1.5 kW RF forward power, were studied for axially viewing ICPOES. The emission intensity profile, excitation temperature and plasma robustness were evaluated, and were similar to those of the standard ICP. The background and emission intensities of elements as well as the excitation behavior for both atom and ion lines were also examined and compared to those of the standard ICP. Since the spectroscopic characteristics of the spiral flow ICP were similar to those of the standard ICP, it could be used as a new low gas flow ICP in axially viewing ICPOES.

  9. Universal relation between spectroscopic constants

    Indian Academy of Sciences (India)

    diatomic molecules, G Herzberg, vol. I, 2nd ed., p. 459, paragraph 2). His wrong definition has resulted in highly erroneous values of re. (2) With our equation lnG = 1.91578 + 0.9711lnA (omitting the standard de- viations) the value of re for Li2 X. 1Σ+ g comes out to be 2.52 oA against the experimental value of 2.6729 oA.

  10. Towards absolute laser spectroscopic CO2 isotope ratio measurements

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Knowledge of isotope composition of carbon dioxide (CO2) in the atmosphere is necessary to identify sources and sinks of this key greenhouse gas. In the last years, laser spectroscopic techniques such as cavity ring-down spectroscopy (CRDS) and tunable diode laser absorption spectroscopy (TDLAS) have been shown to perform accurate isotope ratio measurements for CO2 and other gases like water vapour (H2O) [1,2]. Typically, isotope ratios are reported in literature referring to reference materials provided by e.g. the International Atomic Energy Agency (IAEA). However, there could be some benefit if field deployable absolute isotope ratio measurement methods were developed to address issues such as exhausted reference material like the Pee Dee Belemnite (PDB) standard. Absolute isotope ratio measurements would be particularly important for situations where reference materials do not even exist. Here, we present CRDS and TDLAS-based absolute isotope ratios (13C/12C ) in atmospheric CO2. We demonstrate the capabilities of the used methods by measuring CO2 isotope ratios in gas standards. We compare our results to values reported for the isotope certified gas standards. Guide to the expression of uncertainty in measurement (GUM) compliant uncertainty budgets on the CRDS and TDLAS absolute isotope ratio measurements are presented, and traceability is addressed. We outline the current impediments in realizing high accuracy absolute isotope ratio measurements using laser spectroscopic methods, propose solutions and the way forward. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] B. Kühnreich, S. Wagner, J. C. Habig,·O. Möhler, H. Saathoff, V. Ebert, Appl. Phys. B 119:177-187 (2015). [2] E. Kerstel, L. Gianfrani, Appl. Phys. B 92, 439-449 (2008).

  11. Albumin adsorption on oxide thin films studied by spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Bermudez, P., E-mail: suriel21@yahoo.com [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Circuito Exterior s/n, C.U., 04510, Mexico D.F. (Mexico); Unidad de Posgrado, Facultad de Odontologia, Universidad Nacional Autonoma de Mexico, CU, 04510, Mexico D.F. (Mexico); Rodil, S.E.; Muhl, S. [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Circuito Exterior s/n, C.U., 04510, Mexico D.F. (Mexico)

    2011-12-15

    Thin films of tantalum, niobium, zirconium and titanium oxides were deposited by reactive magnetron sputtering and their wettability and surface energy, optical properties, roughness, chemical composition and microstructure were characterized using contact angle measurements, spectroscopic ellipsometry, profilometry, X-ray photoelectron spectroscopy and X-ray diffraction, respectively. The purpose of the work was to correlate the surface properties of the films to the Bovine Serum Albumin (BSA) adsorption, as a first step into the development of an initial in vitro test of the films biocompatibility, based on standardized protein adsorption essays. The films were immersed into BSA solutions with different protein concentrations and protein adsorption was monitored in situ by dynamic ellipsometry; the adsorption-rate was dependent on the solution concentration and the immersion time. The overall BSA adsorption was studied in situ using spectroscopic ellipsometry and it was found to be influenced by the wettability of the films; larger BSA adsorption occurred on the more hydrophobic surface, the ZrO{sub 2} film. On the Ta{sub 2}O{sub 5}, Nb{sub 2}O{sub 5} and TiO{sub 2} films, hydrophilic surfaces, the overall BSA adsorption increased with the surface roughness or the polar component of the surface energy.

  12. Asiago spectroscopic classification of 3 transients

    Science.gov (United States)

    Tomasella, L.; Benetti, S.; Cappellaro, E.; Turatto, M.

    2018-01-01

    The Asiago Transient Classification Program (Tomasella et al. 2014, AN, 335, 841) reports the spectroscopic classification of AT 2018eq discovered by R. Belligoli (ISSP) in the direction of M31; PS18bq (AT2018bi) discovered by J. Grzegorzek and Pan-STARRS1 in UGC1791; and AT2018C (= Gaia18aak), a blue hostless transient discovered by Gaia.

  13. Ultraviolet spectroscopic evaluation of bioactive saponin fraction ...

    African Journals Online (AJOL)

    Ultraviolet spectroscopic evaluation of bioactive saponin fraction from the aqueous extract of Vernonia amygdalina [Esteraeceae] leaf. Paul Chukwuemeka ADIUKWU 1*, Martina BONSU 1, Inemesit OKON-BEN 1,. Paul PEPRAH 1, Paapa MENSAH-KANE 1, Jonathan JATO 1 and Grace NAMBATYA 2. 1School of Pharmacy ...

  14. Infrared Spectroscopic Imaging for Prostate Pathology Practice

    Science.gov (United States)

    2009-03-01

    imaging data for biochemical markers of tumor and develop numerical algorithms for grading cancer Goal: Develop algorithm for malignancy recognition...genetic algorithm based method to distinguish benign from malignant epithelium using infrared spectroscopic imaging data was shown to be effective...of existing practice. Larger validation studies are needed. 15. SUBJECT TERMS Spectroscopy, prostate, histopathology, cancer , optimization

  15. Ultraviolet spectroscopic evaluation of bioactive saponin fraction ...

    African Journals Online (AJOL)

    The separation and chromatogram development of resulting pure saponin components was carried out using a HPLC with UV-vis detection at 365 nm. Data for the antipyretic study agrees with previous bioactivity report for the saponin. Chromatographic and spectroscopic evaluation indicated the presence of three pure ...

  16. Nanoantenna-Enhanced Infrared Spectroscopic Chemical Imaging.

    Science.gov (United States)

    Kühner, Lucca; Hentschel, Mario; Zschieschang, Ute; Klauk, Hagen; Vogt, Jochen; Huck, Christian; Giessen, Harald; Neubrech, Frank

    2017-05-26

    Spectroscopic infrared chemical imaging is ideally suited for label-free and spatially resolved characterization of molecular species, but often suffers from low infrared absorption cross sections. Here, we overcome this limitation by utilizing confined electromagnetic near-fields of resonantly excited plasmonic nanoantennas, which enhance the molecular absorption by orders of magnitude. In the experiments, we evaporate microstructured chemical patterns of C 60 and pentacene with nanometer thickness on top of homogeneous arrays of tailored nanoantennas. Broadband mid-infrared spectra containing plasmonic and vibrational information were acquired with diffraction-limited resolution using a two-dimensional focal plane array detector. Evaluating the enhanced infrared absorption at the respective frequencies, spatially resolved chemical images were obtained. In these chemical images, the microstructured chemical patterns are only visible if nanoantennas are used. This confirms the superior performance of our approach over conventional spectroscopic infrared imaging. In addition to the improved sensitivity, our technique provides chemical selectivity, which would not be available with plasmonic imaging that is based on refractive index sensing. To extend the accessible spectral bandwidth of nanoantenna-enhanced spectroscopic imaging, we employed nanostructures with dual-band resonances, providing broadband plasmonic enhancement and sensitivity. Our results demonstrate the potential of nanoantenna-enhanced spectroscopic infrared chemical imaging for spatially resolved characterization of organic layers with thicknesses of several nanometers. This is of potential interest for medical applications which are currently hampered by state-of-art infrared techniques, e.g., for distinguishing cancerous from healthy tissues.

  17. Synthesis, spectroscopic characterization and catalytic oxidation ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 123; Issue 3. Synthesis, spectroscopic characterization and catalytic oxidation properties of ONO/ONS donor Schiff base ruthenium(III) complexes containing PPh3/AsPh3. Priyarega M Muthu Tamizh R Karvembu R Prabhakaran K Natarajan. Volume 123 Issue 3 May ...

  18. Time resolved spectroscopic studies on some nanophosphors

    Indian Academy of Sciences (India)

    Wintec

    Abstract. Time resolved spectroscopy is an important tool for studying photophysical processes in phosphors. Present work investigates the steady state and time resolved photoluminescence (PL) spectroscopic characteristics of ZnS, ZnO and (Zn, Mg)O nanophosphors both in powder as well as thin film form.

  19. Highlights of the Brazilian Solar Spectroscope

    Czech Academy of Sciences Publication Activity Database

    Sawant, H. S.; Cecatto, J.R.; Mészárosová, Hana; Faria, C.; Fernandes, F. C. R.; Karlický, Marian; de Andrade, M. C.

    2009-01-01

    Roč. 44, č. 1 (2009), s. 54-57 ISSN 0273-1177 R&D Projects: GA AV ČR IAA300030701 Institutional research plan: CEZ:AV0Z10030501 Keywords : Sun istrumentation * spectroscope * corona * radio radiation Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.079, year: 2009

  20. Photoelectric Radial Velocities, Paper XIX Additional Spectroscopic ...

    Indian Academy of Sciences (India)

    ian velocity curve that does justice to the measurements, but it cannot be expected to have much predictive power. Key words. Stars: late-type—stars: radial velocities—spectroscopic binaries—orbits. 0. Preamble. The 'Redman K stars' are a lot of seventh-magnitude K stars whose radial velocities were first observed by ...

  1. The Gaia-ESO Public Spectroscopic Survey

    DEFF Research Database (Denmark)

    Gilmore, G.; Randich, S.; Asplund, M.

    2012-01-01

    The Gaia-ESO Public Spectroscopic Survey has begun and will obtain high quality spectroscopy of some 100000 Milky Way stars, in the field and in open clusters, down to magnitude 19, systematically covering all the major components of the Milky Way. This survey will provide the first homogeneous...

  2. 8th Czechoslovak spectroscopic conference. Abstracts

    International Nuclear Information System (INIS)

    1988-01-01

    Volume 3 of the conference proceedings contains abstracts of 17 invited papers, 101 poster presentations and 7 papers of instrument manufacturers, devoted to special spectroscopic techniques including X-ray microanalysis, X-ray spectral analysis, Moessbauer spectrometry, mass spectrometry, instrumental activation analysis and other instrumental radioanalytical methods, electron spectrometry, and techniques of environmental analysis. Sixty abstracts were inputted in INIS. (A.K.)

  3. Planar chromatography coupled with spectroscopic techniques.

    NARCIS (Netherlands)

    Somsen, G.W.; Wilson, I.D.; Morden, W.

    1995-01-01

    Recent progress in the combination of planar, or thin-layer chromatography (TLC) with a variety of modern spectroscopic techniques is reviewed. The utility of TLC for separation followed by mass spectrometry, with a variety of ionisation techniques, is illustrated with reference to a wide range of

  4. Synthesis, Spectroscopic and Pharmacological Studies of Bivalent ...

    African Journals Online (AJOL)

    NICO

    Synthesis, Spectroscopic and Pharmacological Studies of. Bivalent Copper, Zinc and Mercury Complexes of Thiourea. Shikha Parmar*, Yatendra Kumar and Ashu Mittal. I.T.S Paramedical College (Pharmacy), Delhi Meerut Road, Muradnagar, Ghaziabad 201206, India. Received 4 June 2010, revised 14 June 2010, ...

  5. Structural, thermal and spectroscopic properties of supramolecular ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 118; Issue 6. Structural, thermal and spectroscopic properties of supramolecular coordination solids ... trans-[M(NC5H4--CO2)2(OH2)4], participate in exhaustive hydrogen-bond formation among themselves to lead to a robust 3D supramolecular network in the solid ...

  6. Performance optimization of spectroscopic process analyzers

    NARCIS (Netherlands)

    Boelens, Hans F. M.; Kok, Wim Th; de Noord, Onno E.; Smilde, Age K.

    2004-01-01

    To increase the power and the robustness of spectroscopic process analyzers, methods are needed that suppress the spectral variation that is not related to the property of interest in the process stream. An approach for the selection of a suitable method is presented. The approach uses the net

  7. Crystallization and spectroscopic studies of manganese malonate

    Indian Academy of Sciences (India)

    Administrator

    Abstract. The preparation of manganese malonate crystals by gel method and its spectroscopic studies are reported. X-ray diffraction (XRD) pattern reveals the crystalline nature. The FTIR and FT Raman spectra of the crystals are recorded and the vibrational assignments are given with possible explanations. Diffuse reflec-.

  8. Raman spectroscopic study of a genetically altered kidney cell

    Science.gov (United States)

    Joshi, Joel; Garcia, Francisco; Centeno, Silvia P.; Joshi, N. V.

    2008-02-01

    A Raman spectroscopic investigation of a genetically altered Human Embryonic Kidney Cell (HEK293) along with a pathologically normal cell has been carried out by a conventional method. The genetic alteration was carried out with a standard protocol by using a Green Fluorescence Protein (GFP). Raman spectra show that there are dramatic differences between the spectrum obtained from a genetically altered cell and that obtained from a pathologically normal cell. The former shows three broad bands; meanwhile the latter shows several sharp peaks corresponding to the ring vibrational modes of Phen, GFP and DNA. The present analysis provides an indication that the force field near Phen located at 64, 65 and 66 was altered during the genetic transformation. The Raman spectrum could be a direct experimental evidence for substantial modifications triggered due to the expression of specific genes.

  9. Fourier transform infrared spectroscopic study of intact cells of the nitrogen-fixing bacterium Azospirillum brasilense

    Science.gov (United States)

    Kamnev, A. A.; Ristić, M.; Antonyuk, L. P.; Chernyshev, A. V.; Ignatov, V. V.

    1997-06-01

    The data of Fourier transform infrared (FTIR) spectroscopic measurements performed on intact cells of the soil nitrogen-fixing bacterium Azospirillum brasilense grown in a standard medium and under the conditions of an increased metal uptake are compared and discussed. The structural FTIR information obtained is considered together with atomic absorption spectrometry (AAS) data on the content of metal cations in the bacterial cells. Some methodological aspects concerning preparation of bacterial cell samples for FTIR measurements are also discussed.

  10. Isolation and spectroscopic studies of curcumin from Philippine Curcuma longa L

    International Nuclear Information System (INIS)

    Torres, Rosalinda C.; Bonifacio, Teresita S.; Herrera, Celia L.; Lanto, Eduardo A.

    1998-01-01

    Curcumin, the yellow coloring matter was isolated from the rhizomes of Philippine Curcuma longa L. (turmeric) by Soxhlet extraction with toluene followed by concentration and slow crystallization. The isolated curcumin was then subjected to chromatographic and spectroscopic studies with the Merck curcumin standard. The infra red and UV-vis spectra of both compounds were found to be almost identical indicating a high purity of the isolate. The % yield obtained was 2-3%. (Author)

  11. The HITRAN2016 molecular spectroscopic database

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, I. E.; Rothman, L. S.; Hill, C.; Kochanov, R. V.; Tan, Y.; Bernath, P. F.; Birk, M.; Boudon, V.; Campargue, A.; Chance, K. V.; Drouin, B. J.; Flaud, J. -M.; Gamache, R. R.; Hodges, J. T.; Jacquemart, D.; Perevalov, V. I.; Perrin, A.; Shine, K. P.; Smith, M. -A. H.; Tennyson, J.; Toon, G. C.; Tran, H.; Tyuterev, V. G.; Barbe, A.; Császár, A. G.; Devi, V. M.; Furtenbacher, T.; Harrison, J. J.; Hartmann, J. -M.; Jolly, A.; Johnson, T. J.; Karman, T.; Kleiner, I.; Kyuberis, A. A.; Loos, J.; Lyulin, O. M.; Massie, S. T.; Mikhailenko, S. N.; Moazzen-Ahmadi, N.; Müller, H. S. P.; Naumenko, O. V.; Nikitin, A. V.; Polyansky, O. L.; Rey, M.; Rotger, M.; Sharpe, S. W.; Sung, K.; Starikova, E.; Tashkun, S. A.; Auwera, J. Vander; Wagner, G.; Wilzewski, J.; Wcisło, P.; Yu, S.; Zak, E. J.

    2017-12-01

    This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is comprised of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 200 additional significant molecules have been added to the database.

  12. Spectroscopic follow up of Kepler planet candidates

    DEFF Research Database (Denmark)

    Latham..[], D. W.; Cochran, W. D.; Marcy, G.W.

    2010-01-01

    and not planets, our strategy is to start with reconnaissance spectroscopy using smaller telescopes, to sort out and reject as many of the false positives as possible before going to Keck. During the first Kepler observing season in 2009, more than 100 nights of telescope time were allocated for this work, using......Spectroscopic follow-up observations play a crucial role in the confirmation and characterization of transiting planet candidates identified by Kepler. The most challenging part of this work is the determination of radial velocities with a precision approaching 1 m/s in order to derive masses from...... spectroscopic orbits. The most precious resource for this work is HIRES on Keck I, to be joined by HARPS-North on the William Herschel Telescope when that new spectrometer comes on line in two years. Because a large fraction of the planet candidates are in fact stellar systems involving eclipsing stars...

  13. Spectroscopic follow up of Kepler planet candidates

    DEFF Research Database (Denmark)

    Latham..[], D. W.; Cochran, W. D.; Marcy, G.W.

    2010-01-01

    Spectroscopic follow-up observations play a crucial role in the confirmation and characterization of transiting planet candidates identified by Kepler. The most challenging part of this work is the determination of radial velocities with a precision approaching 1 m/s in order to derive masses from...... spectroscopic orbits. The most precious resource for this work is HIRES on Keck I, to be joined by HARPS-North on the William Herschel Telescope when that new spectrometer comes on line in two years. Because a large fraction of the planet candidates are in fact stellar systems involving eclipsing stars...... and not planets, our strategy is to start with reconnaissance spectroscopy using smaller telescopes, to sort out and reject as many of the false positives as possible before going to Keck. During the first Kepler observing season in 2009, more than 100 nights of telescope time were allocated for this work, using...

  14. Spectroscopic Chemical Analysis Methods and Apparatus

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor)

    2017-01-01

    Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

  15. Proton MR spectroscopic features of the human liver: in-vivo application to the normal condition

    International Nuclear Information System (INIS)

    Cho, Soon Gu; Kim, Mi Young; Kim, Young Soo; Choi, Won; Shin, Seok Hwan; Ok, Chul Soo; Suh, Chang Hae

    1999-01-01

    To determine the feasibility of MR spectroscopy in the living human liver, and to evaluate the corresponding proton MR spectroscopic features. In fifteen normal volunteers with neither previous nor present liver disease, the proton MR spectroscopic findings were reviewed. Twelve subjects were male and three were female ; they were aged between 28 and 32 (mean, 30) years. MR spectroscopy involved the use of a 1.5T GE Signa Horizon system with body coil(GE Medical System, Milwaukee, U.S.A). We used STEAM (Stimulated Echo-Acquisition Mode) with 3000/30 msec of TR/TE for signal acquisition, and the prone position without respiratory interruption. Mean and standard deviation of the ratios of glutamate+glutamine/lipids, phosphomonoesters/lipids, and glycogen+glucose/lipids were calculated from the area of their peaks. The proton MR spectroscopic findings of normal human livers showed four distinctive peaks, i.e. lipids, glutamate and glutamine complex, phosphomonoesters, and glycogen and glucose complex. The mean and standard deviation of the ratios of glutamate+glutamine/lipids, phosphomonoesters/lipids, and glycogen+glucose/lipids were 0.02±0.01, 0.01±0.01, and 0.04±0.03, respectively. In living normal human livers, MR spectroscopy can be successfully applied. When applied to a liver whose condition is pathologic, the findings can be used as a standard

  16. The Gaia-ESO Public Spectroscopic Survey

    OpenAIRE

    Gilmore, G.; Randich, S.; Asplund, M.; Binney, J.; Bonifacio, P.; Drew, J.; Feltzing, S.; Ferguson, A.; Jeffries, R.; Micela, G.; Negueruela, I.; Prusti, T.; Rix, H.-W.; Vallenari, A.; Alfaro, E.

    2012-01-01

    The Gaia-ESO Public Spectroscopic Survey has begun and will obtain high quality spectroscopy of some 100000 Milky Way stars, in the field and in open clusters, down to magnitude 19, systematically covering all the major components of the Milky Way. This survey will provide the first homogeneous overview of the distributions of kinematics and chemical element abundances in the Galaxy. The motivation, organisation and implementation of the Gaia-ESO Survey are described, emphasising the compleme...

  17. Spectroscopic Parameters of Lumbar Intervertebral Disc Material

    Science.gov (United States)

    Terbetas, G.; Kozlovskaja, A.; Varanius, D.; Graziene, V.; Vaitkus, J.; Vaitkuviene, A.

    2009-06-01

    There are numerous methods of investigating intervertebral disc. Visualization methods are widely used in clinical practice. Histological, imunohistochemical and biochemical methods are more used in scientific research. We propose that a new spectroscopic investigation would be useful in determining intervertebral disc material, especially when no histological specimens are available. Purpose: to determine spectroscopic parameters of intervertebral disc material; to determine emission spectra common for all intervertebral discs; to create a background for further spectroscopic investigation where no histological specimen will be available. Material and Methods: 20 patients, 68 frozen sections of 20 μm thickness from operatively removed intervertebral disc hernia were excited by Nd:YAG microlaser STA-01-TH third harmonic 355 nm light throw 0, 1 mm fiber. Spectrophotometer OceanOptics USB2000 was used for spectra collection. Mathematical analysis of spectra was performed by ORIGIN multiple Gaussian peaks analysis. Results: In each specimen of disc hernia were found distinct maximal spectral peaks of 4 types supporting the histological evaluation of mixture content of the hernia. Fluorescence in the spectral regions 370-700 nm was detected in the disc hernias. The main spectral component was at 494 nm and the contribution of the components with the peak wavelength values at 388 nm, 412 nm and 435±5 nm were varying in the different groups of samples. In comparison to average spectrum of all cases, there are 4 groups of different spectral signatures in the region 400-500 nm in the patient groups, supporting a clinical data on different clinical features of the patients. Discussion and Conclusion: besides the classical open discectomy, new minimally invasive techniques of treating intervertebral disc emerge (PLDD). Intervertebral disc in these techniques is assessed by needle, no histological specimen is taken. Spectroscopic investigation via fiber optics through the

  18. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  19. Quantum chemical calculations and spectroscopic measurements of spectroscopic and thermodynamic properties of given uranyl complexes in aqueous solutions with possible environmental and industrial applications

    Science.gov (United States)

    Višňak, Jakub; Sobek, Lukáš

    2016-11-01

    A brief introduction into computational methodology and preliminary results for spectroscopic (excitation energies, vibrational frequencies in ground and excited electronic states) and thermodynamic (stability constants, standard enthalpies and entropies of complexation reactions) properties of some 1:1, 1:2 and 1:3 uranyl sulphato- and selenato- complexes in aqueos solutions will be given. The relativistic effects are included via Effective Core Potential (ECP), electron correlation via (TD)DFT/B3LYP (dispersion interaction corrected) and solvation is described via explicit inclusion of one hydration sphere beyond the coordinated water molecules. We acknowledge limits of this approximate description - more accurate calculations (ranging from semi-phenomenological two-component spin-orbit coupling up to four-component Dirac-Coulomb-Breit hamiltonian) and Molecular Dynamics simulations are in preparation. The computational results are compared with the experimental results from Time-resolved Laser-induced Fluorescence Spectroscopy (TRLFS) and UV-VIS spectroscopic studies (including our original experimental research on this topic). In case of the TRLFS and UV-VIS speciation studies, the problem of complex solution spectra decomposition into individual components is ill-conditioned and hints from theoretical chemistry could be very important. Qualitative agreement between our quantum chemical calculations of the spectroscopic properties and experimental data was achieved. Possible applications for geochemical modelling (e.g. safety studies of nuclear waste repositories, modelling of a future mining site) and analytical chemical studies (including natural samples) are discussed.

  20. Quantum chemical calculations and spectroscopic measurements of spectroscopic and thermodynamic properties of given uranyl complexes in aqueous solutions with possible environmental and industrial applications

    Directory of Open Access Journals (Sweden)

    Višňak Jakub

    2016-01-01

    Full Text Available A brief introduction into computational methodology and preliminary results for spectroscopic (excitation energies, vibrational frequencies in ground and excited electronic states and thermodynamic (stability constants, standard enthalpies and entropies of complexation reactions properties of some 1:1, 1:2 and 1:3 uranyl sulphato- and selenato- complexes in aqueos solutions will be given. The relativistic effects are included via Effective Core Potential (ECP, electron correlation via (TDDFT/B3LYP (dispersion interaction corrected and solvation is described via explicit inclusion of one hydration sphere beyond the coordinated water molecules. We acknowledge limits of this approximate description – more accurate calculations (ranging from semi-phenomenological two-component spin-orbit coupling up to four-component Dirac-Coulomb-Breit hamiltonian and Molecular Dynamics simulations are in preparation. The computational results are compared with the experimental results from Time-resolved Laser-induced Fluorescence Spectroscopy (TRLFS and UV-VIS spectroscopic studies (including our original experimental research on this topic. In case of the TRLFS and UV-VIS speciation studies, the problem of complex solution spectra decomposition into individual components is ill-conditioned and hints from theoretical chemistry could be very important. Qualitative agreement between our quantum chemical calculations of the spectroscopic properties and experimental data was achieved. Possible applications for geochemical modelling (e.g. safety studies of nuclear waste repositories, modelling of a future mining site and analytical chemical studies (including natural samples are discussed.

  1. Accounting standards

    NARCIS (Netherlands)

    Stellinga, B.; Mügge, D.

    2014-01-01

    The European and global regulation of accounting standards have witnessed remarkable changes over the past twenty years. In the early 1990s, EU accounting practices were fragmented along national lines and US accounting standards were the de facto global standards. Since 2005, all EU listed

  2. Enhancing forensic science with spectroscopic imaging

    Science.gov (United States)

    Ricci, Camilla; Kazarian, Sergei G.

    2006-09-01

    This presentation outlines the research we are developing in the area of Fourier Transform Infrared (FTIR) spectroscopic imaging with the focus on materials of forensic interest. FTIR spectroscopic imaging has recently emerged as a powerful tool for characterisation of heterogeneous materials. FTIR imaging relies on the ability of the military-developed infrared array detector to simultaneously measure spectra from thousands of different locations in a sample. Recently developed application of FTIR imaging using an ATR (Attenuated Total Reflection) mode has demonstrated the ability of this method to achieve spatial resolution beyond the diffraction limit of infrared light in air. Chemical visualisation with enhanced spatial resolution in micro-ATR mode broadens the range of materials studied with FTIR imaging with applications to pharmaceutical formulations or biological samples. Macro-ATR imaging has also been developed for chemical imaging analysis of large surface area samples and was applied to analyse the surface of human skin (e.g. finger), counterfeit tablets, textile materials (clothing), etc. This approach demonstrated the ability of this imaging method to detect trace materials attached to the surface of the skin. This may also prove as a valuable tool in detection of traces of explosives left or trapped on the surfaces of different materials. This FTIR imaging method is substantially superior to many of the other imaging methods due to inherent chemical specificity of infrared spectroscopy and fast acquisition times of this technique. Our preliminary data demonstrated that this methodology will provide the means to non-destructive detection method that could relate evidence to its source. This will be important in a wider crime prevention programme. In summary, intrinsic chemical specificity and enhanced visualising capability of FTIR spectroscopic imaging open a window of opportunities for counter-terrorism and crime-fighting, with applications ranging

  3. PRIMitive Asteroids Spectroscopic Survey - PRIMASS: First Results

    Science.gov (United States)

    de Leon, Julia; Pinilla-Alonso, Noemi; Campins, Humberto; Lorenzi, Vania; Licandro, Javier; Morate, David; Tanga, Paolo; Cellino, Alberto; Delbo, Marco

    2015-11-01

    NASA OSIRIS-REx and JAXA Hayabusa 2 sample-return missions have targeted two near-Earth asteroids: (101955) Bennu and (162173) 1999 JU3, respectively. These are primitive asteroids that are believed to originate in the inner belt, where five distinct sources have been identified: four primitive collisional families (Polana, Erigone, Sulamitis, and Clarissa), and a population of low-albedo and low-inclination background asteroids. Identifying and characterizing the populations from which these two NEAs might originate will enchance the science return of the two missions.With this main objective in mind, we initiated in 2010 a spectroscopic survey in the visible and the near-infrared to characterize the primitive collisional families in the inner belt and the low-albedo background population. This is the PRIMitive Asteroids Spectroscopic Survey - PRIMASS. So far we have obtained more than 200 spectra using telescopes located at different observatories. PRIMASS uses a variety of ground based facilities. Most of the spectra have been obtained using the 10.4m Gran Telescopio Canarias (GTC), and the 3.6m Telescopio Nazionale Galileo (TNG), both located at the El Roque de los Muchachos Observatory (La Palma, Spain), and the 3.0m NASA Infrared Telescope Facility on Mauna Kea (Hawai, USA).We present the first results from our on-going survey (de Leon et al. 2015; Pinilla-Alonso et al. 2015; Morate et al. 2015), focused on the Polana and the Erigone primitive families, with visible and near-infrared spectra of more than 200 objects, most of them with no previous spectroscopic data. Our survey is already the largest database of primitive asteroids spectra, and we keep obtaining data on the Sulamitis and the Clarissa families, as well as on the background low-albedo population.

  4. Exploratory multivariate spectroscopic study on human skin.

    Science.gov (United States)

    Lauridsen, Rikke Kragh; Everland, Hanne; Nielsen, Lene Feldskov; Engelsen, Søren Balling; Nørgaard, Lars

    2003-05-01

    Spectroscopy on human skin is a field that is being adopted increasingly because of its rapidity and high reproducibility. Infrared reflectance (IR), near-infrared reflectance (NIR), and fluorescence spectroscopy have previously been applied to human skin in vivo to compare healthy and sick skin, including skin cancer, atopy, and leprosy. Exploratory data analysis/chemometrics is a tool for evaluating multivariate data such as spectroscopic measurements. The objective of this study was to explore the spectral variance spanned by people with normal integument, and to demonstrate the advantages of multivariate analysis to skin research. IR, NIR and fluorescence spectroscopy have been carried out in vivo on 216 volunteers' forearms before and after four tape strippings. The subjects were asked to fill in a questionnaire regarding factors suspected to influence the measurement results. Principal Component Analysis (PCA) was used to investigate whether the population can be divided into groups on the basis of their skin chemistry. Unless otherwise stated, the results are from the measurements prior to stripping. In contrast to IR and fluorescence spectra, NIR spectra proved able to detect gender differences. By use of PCA, classifications on male and female subjects were observed from the IR and NIR measurements, and as an indication from the fluorescence measurements. The NIR and fluorescence measurements varied between elderly and young subjects. The largest variance in the fluorescence landscapes was seen between pigmented and non-pigmented skin. No connection was found between the spectroscopic measurements and smoking or drinking habits. Future spectroscopic skin investigations should be balanced as regards to gender and age, as these can possibly affect the measurement results. Chemometrics proved to be superior to traditional attempts of interpreting the spectra.

  5. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  6. Spectroscopic methods in gas hydrate research.

    Science.gov (United States)

    Rauh, Florian; Mizaikoff, Boris

    2012-01-01

    Gas hydrates are crystalline structures comprising a guest molecule surrounded by a water cage, and are particularly relevant due to their natural occurrence in the deep sea and in permafrost areas. Low molecular weight molecules such as methane and carbon dioxide can be sequestered into that cage at suitable temperatures and pressures, facilitating the transition to the solid phase. While the composition and structure of gas hydrates appear to be well understood, their formation and dissociation mechanisms, along with the dynamics and kinetics associated with those processes, remain ambiguous. In order to take advantage of gas hydrates as an energy resource (e.g., methane hydrate), as a sequestration matrix in (for example) CO(2) storage, or for chemical energy conservation/storage, a more detailed molecular level understanding of their formation and dissociation processes, as well as the chemical, physical, and biological parameters that affect these processes, is required. Spectroscopic techniques appear to be most suitable for analyzing the structures of gas hydrates (sometimes in situ), thus providing access to such information across the electromagnetic spectrum. A variety of spectroscopic methods are currently used in gas hydrate research to determine the composition, structure, cage occupancy, guest molecule position, and binding/formation/dissociation mechanisms of the hydrate. To date, the most commonly applied techniques are Raman spectroscopy and solid-state nuclear magnetic resonance (NMR) spectroscopy. Diffraction methods such as neutron and X-ray diffraction are used to determine gas hydrate structures, and to study lattice expansions. Furthermore, UV-vis spectroscopic techniques and scanning electron microscopy (SEM) have assisted in structural studies of gas hydrates. Most recently, waveguide-coupled mid-infrared spectroscopy in the 3-20 μm spectral range has demonstrated its value for in situ studies on the formation and dissociation of gas

  7. Spectroscopic investigations of carious tooth decay.

    Science.gov (United States)

    Thareja, R K; Sharma, A K; Shukla, Shobha

    2008-11-01

    We report on the elemental composition of healthy and infected part of human tooth using laser induced breakdown spectroscopy (LIBS). We have used prominent constituent transitions in laser-excited tooth to diagnose the state of the tooth. A nanosecond laser pulse (355nm, 5ns) was used as an ablating pulse and the sodium (3s2S-3p2P) at 588.99 and (3s2S-3p2P) at 589.99nm, strontium (5s21S-1s5P) at 460.55nm, and calcium (3d3D-4f 3F0) at 452.55nm transitions for spectroscopic analysis. The spectroscopic observations in conjunction with discriminate analysis showed that calcium attached to the hydroxyapatite structure of the tooth was affected severely at the infected part of the tooth. The position-time plots generated from two-dimensional (2D) images conclusively showed a decrease in calcium concentration in the infected region of the irradiated tooth. Using the technique, we could distinguish between the healthy and carious parts of the tooth with significant accuracy.

  8. Infrared Spectroscopic Imaging: The Next Generation

    Science.gov (United States)

    Bhargava, Rohit

    2013-01-01

    Infrared (IR) spectroscopic imaging seemingly matured as a technology in the mid-2000s, with commercially successful instrumentation and reports in numerous applications. Recent developments, however, have transformed our understanding of the recorded data, provided capability for new instrumentation, and greatly enhanced the ability to extract more useful information in less time. These developments are summarized here in three broad areas— data recording, interpretation of recorded data, and information extraction—and their critical review is employed to project emerging trends. Overall, the convergence of selected components from hardware, theory, algorithms, and applications is one trend. Instead of similar, general-purpose instrumentation, another trend is likely to be diverse and application-targeted designs of instrumentation driven by emerging component technologies. The recent renaissance in both fundamental science and instrumentation will likely spur investigations at the confluence of conventional spectroscopic analyses and optical physics for improved data interpretation. While chemometrics has dominated data processing, a trend will likely lie in the development of signal processing algorithms to optimally extract spectral and spatial information prior to conventional chemometric analyses. Finally, the sum of these recent advances is likely to provide unprecedented capability in measurement and scientific insight, which will present new opportunities for the applied spectroscopist. PMID:23031693

  9. Spectroscopic studies of pulsed-power plasmas

    International Nuclear Information System (INIS)

    Maron, Y.; Arad, R.; Dadusc, G.; Davara, G.; Duvall, R.E.; Fisher, V.; Foord, M.E.; Fruchtman, A.; Gregorian, L.; Krasik, Ya.

    1993-01-01

    Recently developed spectroscopic diagnostic techniques are used to investigate the plasma behavior in a Magnetically Insulated Ion Diode, a Plasma Opening Switch, and a gas-puffed Z-pinch. Measurements with relatively high spectral, temporal, and spatial resolutions are performed. The particle velocity and density distributions within a few tens of microns from the dielectric-anode surface are observed using laser spectroscopy. Collective fluctuating electric fields in the plasma are inferred from anisotropic Stark broadening. For the Plasma Opening Switch experiment, a novel gaseous plasma source was developed which is mounted inside the high-voltage inner conductor. The properties of this source, together with spectroscopic observations of the electron density and particle velocities of the injected plasma, are described. Emission line intensities and spectral profiles give the electron kinetic energies during the switch operation and the ion velocity distributions. Secondary plasma ejection from the electrodes is also studied. In the Z-pinch experiment, spectral emission-line profiles are studied during the implosion phase. Doppler line shifts and widths yield the radial velocity distributions for various charge states in various regions of the plasma. Effects of plasma ejection from the cathode are also studied

  10. Spectroscopic Analysis of Planetary Host Stars

    Science.gov (United States)

    Rittipruk, P.; Yushchenko, A.; Kang, Y. W.

    2014-08-01

    We observed the high resolution spectra of extra-solar planet host stars. The spectroscopic data of host stars were observed using the CHIRON echelle spectrometer and R-C Spectrograph for magnetic activity on the SMART-1.5 meter telescope at CTIO, Chile. The analysis of spectroscopic data was performed using URAN and SYNTHE programs. These spectra allow us to determine the effective temperatures, surface gravities, microturbulent velocities and, finally, the chemical composition of the hosts was obtained by spectrum synthesis. One of the targets, namely HD 47536, the host of two planets, appeared to be a halo star with overabundances of neutron capture elements. The effective temperature and the surface gravity of this star are 4400 K and log=1.5 respectively, the iron is underabundant by 0.6 dex. The heavy elements (up to thorium, Z=90) show the overabundances with respect to iron. The signs of accretion of interstellar gas are found in the atmosphere of this star.

  11. Spectroscopic enhancement in nanoparticles embedded glasses

    Energy Technology Data Exchange (ETDEWEB)

    Sahar, M. R., E-mail: mrahim057@gmail.com; Ghoshal, S. K., E-mail: mrahim057@gmail.com [Advanced Optical Material Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310, Skudai, Johor Bahru, Johor (Malaysia)

    2014-09-25

    This presentation provides an overview of the recent progress in the enhancement of the spectroscopic characteristics of the glass embedded with nanoparticles (NPs). Some of our research activities with few significantly new results are highlighted and facilely analyzed. The science and technology dealing with the manipulation of the physical properties of rare earth doped inorganic glasses by embedding metallic NPs or nanoclusters produce the so-called 'nanoglass'. Meanwhile, the spectroscopic enhancement relates the intensity of the luminescence measured at certain transition. The enhancement which expectedly due to the 'plasmonics wave' (referring to the coherent coupling of photons to free electron oscillations called plasmon) occurs at the interface between a conductor and a dielectric. Plasmonics being an emerging concept in advanced optical material of nanophotonics has given this material the ability to exploit the optical response at nanoscale and opened up a new avenue in metal-based glass optics. There is a vast array of plasmonic NPs concepts yet to be explored, with applications spanning solar cells, (bio) sensing, communications, lasers, solid-state lighting, waveguides, imaging, optical data transfer, display and even bio-medicine. Localized surface plasmon resonance (LSPR) can enhance the optical response of nanoglass by orders of magnitude as observed. The luminescence enhancement and surface enhanced Raman scattering (SERS) are new paradigm of research. The enhancement of luminescence due to the influence of metallic NPs is the recurring theme of this paper.

  12. Grating Spectroscopes and How to Use Them

    CERN Document Server

    Harrison, Ken M

    2012-01-01

    Transmission grating spectroscopes look like simple filters and are designed to screw into place on the eyepiece tube of a telescope for visual use, or into a camera adapter for digicam or CCD imaging. They are relatively inexpensive and by far the easiest type of astronomical spectroscope to use, and so are the starting point for most beginners. Using the most popular commercially made filter gratings - from Rainbow Optics in the United States to Star Analyser in the United Kingdon - as examples, the book provides all the information needed to set up and use the grating to obtain stellar spectra. It also presents methods of analyzing the results. No heavy mathematics or formulas are involved, although a reasonable level of proficiency in using an astronomic telescope and, if relevant, imaging camera, is assumed. This book contains many practical hints and tips - something that is almost essential to success when starting out. It encourages new users to get quick results, and by following the worked examples,...

  13. The HITRAN 2004 molecular spectroscopic database

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, L.S. [Harvard-Smithsonian Center for Astrophysics, Atomic and Molecular Physics Division, Cambridge, MA 02138 (United States)]. E-mail: lrothman@cfa.harvard.edu; Jacquemart, D. [Harvard-Smithsonian Center for Astrophysics, Atomic and Molecular Physics Division, Cambridge, MA 02138 (United States); Barbe, A. [Universite de Reims-Champagne-Ardenne, Groupe de Spectrometrie Moleculaire et Atmospherique, 51062 Reims (France)] (and others)

    2005-12-01

    This paper describes the status of the 2004 edition of the HITRAN molecular spectroscopic database. The HITRAN compilation consists of several components that serve as input for radiative transfer calculation codes: individual line parameters for the microwave through visible spectra of molecules in the gas phase; absorption cross-sections for molecules having dense spectral features, i.e., spectra in which the individual lines are unresolvable; individual line parameters and absorption cross-sections for bands in the ultra-violet; refractive indices of aerosols; tables and files of general properties associated with the database; and database management software. The line-by-line portion of the database contains spectroscopic parameters for 39 molecules including many of their isotopologues. The format of the section of the database on individual line parameters of HITRAN has undergone the most extensive enhancement in almost two decades. It now lists the Einstein A-coefficients, statistical weights of the upper and lower levels of the transitions, a better system for the representation of quantum identifications, and enhanced referencing and uncertainty codes. In addition, there is a provision for making corrections to the broadening of line transitions due to line mixing.

  14. The HITRAN 2004 molecular spectroscopic database

    International Nuclear Information System (INIS)

    Rothman, L.S.; Jacquemart, D.; Barbe, A.

    2005-01-01

    This paper describes the status of the 2004 edition of the HITRAN molecular spectroscopic database. The HITRAN compilation consists of several components that serve as input for radiative transfer calculation codes: individual line parameters for the microwave through visible spectra of molecules in the gas phase; absorption cross-sections for molecules having dense spectral features, i.e., spectra in which the individual lines are unresolvable; individual line parameters and absorption cross-sections for bands in the ultra-violet; refractive indices of aerosols; tables and files of general properties associated with the database; and database management software. The line-by-line portion of the database contains spectroscopic parameters for 39 molecules including many of their isotopologues. The format of the section of the database on individual line parameters of HITRAN has undergone the most extensive enhancement in almost two decades. It now lists the Einstein A-coefficients, statistical weights of the upper and lower levels of the transitions, a better system for the representation of quantum identifications, and enhanced referencing and uncertainty codes. In addition, there is a provision for making corrections to the broadening of line transitions due to line mixing

  15. Anomalous Centrifugal Distortion in HDO and Spectroscopic Data Bases

    Science.gov (United States)

    Coudert, L. H.

    2015-06-01

    The HDO molecule is important from the atmospheric point of view as it can be used to study the water cycle in the earth atmosphere. It is also interesting from the spectroscopic point of view as it displays an anomalous centrifugal distortion similar to that of the normal species H_2O. A model developed to treat the anomalous distortion in HDO should account for the fact that it lacks a two-fold axis of symmetry. A new treatment aimed at the calculation of the rovibrational energy of the HDO molecule and allowing for anomalous centrifugal distortion effects has been developed. It is based on an effective Hamiltonian in which the large amplitude bending ν_2 mode and the overall rotation of the molecule are treated simultaneously. Due to the lack of a two-fold axis of symmetry, this effective Hamiltonian contains terms arising from the non-diagonal component of the inertia tensor and from the Coriolis-coupling between the large amplitude bending ν_2 mode and the overall rotation of the molecule. This new treatment has been used to perform a line position analysis of a large body of infrared, microwave, and hot water vapor data involving the ground and (010) states up to J=22. For these 4413 data, a unitless standard deviation of 1.1 was achieved. A line intensity analysis was also carried out and allowed us to reproduce the strength of 1316 transitions^c with a unitless standard deviation of 1.1. In the talk, the new theoretical approach will be presented. The results of both analyses will be discussed and compared with those of a previous investigation. The new spectroscopic data base built will be compared with HITRAN 2012. Herbin et al., Atmos. Chem. Phys.~9 (2009) 9433; and Schneider and Hase, Atmos. Chem. Phys.~ 11 (2011) 11207. Coudert, Wagner, Birk, Baranov, Lafferty, and Flaud, J. Molec. Spectrosc.~251 (2008) 339. Johns, J. Opt. Soc. Am. B~2 (1985) 1340 Toth, J. Molec. Spectrosc.~162 (1993) 20 Paso and Horneman, J. Opt. Soc. Am. B~12 (1995) 1813 Toth, J

  16. Communications standards

    CERN Document Server

    Stokes, A V

    1986-01-01

    Communications Standards deals with the standardization of computer communication networks. This book examines the types of local area networks (LANs) that have been developed and looks at some of the relevant protocols in more detail. The work of Project 802 is briefly discussed, along with a protocol which has developed from one of the LAN standards and is now a de facto standard in one particular area, namely the Manufacturing Automation Protocol (MAP). Factors that affect the usage of networks, such as network management and security, are also considered. This book is divided into three se

  17. Iterative estimation of the background in noisy spectroscopic data

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, M.H. [Space Exploration Laboratory, Macao University of Science and Technology, Taipa (Macao)], E-mail: peter_zu@163.com; Liu, L.G.; Cheng, Y.S.; Dong, T.K.; You, Z.; Xu, A.A. [Space Exploration Laboratory, Macao University of Science and Technology, Taipa (Macao)

    2009-04-21

    In this paper, we present an iterative filtering method to estimate the background of noisy spectroscopic data. The proposed method avoids the calculation of the average full width at half maximum (FWHM) of the whole spectrum and the peak regions, and it can estimate the background efficiently, especially for spectroscopic data with the Compton continuum.

  18. Preparation of cesium targets for gamma-spectroscopic studies

    Science.gov (United States)

    Bhattacharyya, S.; Basu, S. K.; Chanda, S.; Deb, P.; Eqbal, Md; Kundu, S.; Joseph, D.

    2000-11-01

    A procedure to prepare monoisotopic cesium compound targets for gamma-spectroscopic experiments is described. Using this procedure, uniform targets up to thicknesses of 0.6-1.2 mg/cm 2 were prepared and used for in-beam spectroscopic studies. The purity of the target was tested by energy dispersive X-ray fluorescence (EDXRF) measurements.

  19. Fundamental spectroscopic studies of carbenes and hydrocarbon radicals

    Energy Technology Data Exchange (ETDEWEB)

    Gottlieb, C.A.; Thaddeus, P. [Harvard Univ., Cambridge, MA (United States)

    1993-12-01

    Highly reactive carbenes and carbon-chain radicals are studied at millimeter wavelengths by observing their rotational spectra. The purpose is to provide definitive spectroscopic identification, accurate spectroscopic constants in the lowest vibrational states, and reliable structures of the key intermediates in reactions leading to aromatic hydrocarbons and soot particles in combustion.

  20. Deformed shell model studies of spectroscopic properties of Zn and ...

    Indian Academy of Sciences (India)

    2014-04-05

    Apr 5, 2014 ... the generating coordinate method framework (GCM+PNAMP), (v) projected Hartree– ... shall first study its spectroscopic properties using deformed shell model (DSM) to test the effectiveness of the model for ... Section. 3 gives DSM results for 64Zn for spectroscopic properties and then the results for both 2ν.

  1. Spectroscopic factors for two-proton radioactive nuclei

    Indian Academy of Sciences (India)

    This method has been used in ref. [1] for the calculation of spectroscopic factors of one-proton emitting systems but so far has not been applied to the two-proton case. In this paper, we present calculations of spectroscopic factor for two-proton unstable nuclei in the framework of the inde- pendent quasiparticle BCS model.

  2. Velocity Curve Studies of Spectroscopic Binary Stars V380 Cygni ...

    Indian Academy of Sciences (India)

    Abstract. Using measured radial velocity data of five double lined spectroscopic binary systems V380 Cygni, V401 Cyg, V523 Cas, V373 Cas and V2388 Oph, we find corresponding orbital and spectroscopic elements via the method introduced by Karami & Mohebi (2007) and Karami &. Teimoorinia (2007). Our numerical ...

  3. Spectroscopic Needs for Imaging Dark Energy Experiments

    International Nuclear Information System (INIS)

    Newman, Jeffrey A.; Abate, Alexandra; Abdalla, Filipe B.; Allam, Sahar; Allen, Steven W.; Ansari, Reza; Bailey, Stephen; Barkhouse, Wayne A.; Beers, Timothy C.; Blanton, Michael R.; Brodwin, Mark; Brownstein, Joel R.; Brunner, Robert J.; Carrasco-Kind, Matias; Cervantes-Cota, Jorge; Chisari, Nora Elisa; Colless, Matthew; Coupon, Jean; Cunha, Carlos E.; Frye, Brenda L.; Gawiser, Eric J.; Gehrels, Neil; Grady, Kevin; Hagen, Alex; Hall, Patrick B.; Hearin, Andrew P.; Hildebrandt, Hendrik; Hirata, Christopher M.; Ho, Shirley; Huterer, Dragan; Ivezic, Zeljko; Kneib, Jean-Paul; Kruk, Jeffrey W.; Lahav, Ofer; Mandelbaum, Rachel; Matthews, Daniel J.; Miquel, Ramon; Moniez, Marc; Moos, H. W.; Moustakas, John; Papovich, Casey; Peacock, John A.; Rhodes, Jason; Ricol, Jean-Stepane; Sadeh, Iftach; Schmidt, Samuel J.; Stern, Daniel K.; Tyson, J. Anthony; Von der Linden, Anja; Wechsler, Risa H.; Wood-Vasey, W. M.; Zentner, A.

    2015-01-01

    Ongoing and near-future imaging-based dark energy experiments are critically dependent upon photometric redshifts (a.k.a. photo-z's): i.e., estimates of the redshifts of objects based only on flux information obtained through broad filters. Higher-quality, lower-scatter photo-z's will result in smaller random errors on cosmological parameters; while systematic errors in photometric redshift estimates, if not constrained, may dominate all other uncertainties from these experiments. The desired optimization and calibration is dependent upon spectroscopic measurements for secure redshift information; this is the key application of galaxy spectroscopy for imaging-based dark energy experiments. Hence, to achieve their full potential, imaging-based experiments will require large sets of objects with spectroscopically-determined redshifts, for two purposes: Training: Objects with known redshift are needed to map out the relationship between object color and z (or, equivalently, to determine empirically-calibrated templates describing the rest-frame spectra of the full range of galaxies, which may be used to predict the color-z relation). The ultimate goal of training is to minimize each moment of the distribution of differences between photometric redshift estimates and the true redshifts of objects, making the relationship between them as tight as possible. The larger and more complete our ''training set'' of spectroscopic redshifts is, the smaller the RMS photo-z errors should be, increasing the constraining power of imaging experiments; Requirements: Spectroscopic redshift measurements for ∼30,000 objects over >∼15 widely-separated regions, each at least ∼20 arcmin in diameter, and reaching the faintest objects used in a given experiment, will likely be necessary if photometric redshifts are to be trained and calibrated with conventional techniques. Larger, more complete samples (i.e., with longer exposure times) can improve photo

  4. Achieving Standardization

    DEFF Research Database (Denmark)

    Henningsson, Stefan

    2016-01-01

    competitive, national customs and regional economic organizations are seeking to establish a standardized solution for digital reporting of customs data. However, standardization has proven hard to achieve in the socio-technical e-Customs solution. In this chapter, the authors identify and describe what has......International e-Customs is going through a standardization process. Driven by the need to increase control in the trade process to address security challenges stemming from threats of terrorists, diseases, and counterfeit products, and to lower the administrative burdens on traders to stay...... to be harmonized in order for a global company to perceive e-Customs as standardized. In doing so, they contribute an explanation of the challenges associated with using a standardization mechanism for harmonizing socio-technical information systems....

  5. Achieving Standardization

    DEFF Research Database (Denmark)

    Henningsson, Stefan

    2014-01-01

    competitive, national customs and regional economic organizations are seeking to establish a standardized solution for digital reporting of customs data. However, standardization has proven hard to achieve in the socio-technical e-Customs solution. In this chapter, the authors identify and describe what has......International e-Customs is going through a standardization process. Driven by the need to increase control in the trade process to address security challenges stemming from threats of terrorists, diseases, and counterfeit products, and to lower the administrative burdens on traders to stay...... to be harmonized in order for a global company to perceive e-Customs as standardized. In doing so, they contribute an explanation of the challenges associated with using a standardization mechanism for harmonizing socio-technical information systems....

  6. Training Standardization

    International Nuclear Information System (INIS)

    Agnihotri, Newal

    2003-01-01

    The article describes the benefits of and required process and recommendations for implementing the standardization of training in the nuclear power industry in the United States and abroad. Current Information and Communication Technologies (ICT) enable training standardization in the nuclear power industry. The delivery of training through the Internet, Intranet and video over IP will facilitate this standardization and bring multiple benefits to the nuclear power industry worldwide. As the amount of available qualified and experienced professionals decreases because of retirements and fewer nuclear engineering institutions, standardized training will help increase the number of available professionals in the industry. Technology will make it possible to use the experience of retired professionals who may be interested in working part-time from a remote location. Well-planned standardized training will prevent a fragmented approach among utilities, and it will save the industry considerable resources in the long run. It will also ensure cost-effective and safe nuclear power plant operation

  7. PRIMitive Asteroids Spectroscopic Survey - PRIMASS: Current Status

    Science.gov (United States)

    Pinilla-Alonso, Noemí; de León, Julia; Morate, David; de Prá, Mario; Lorenzi, Vania; Licandro, Javier; Campins, Humberto; Ali-Lagoa, Victor

    2017-10-01

    Primitive asteroids contain the most pristine material that gave birth to the rocky planets. Interest in spectral data from primitive asteroids that could be the source of the primitive near-Earth asteroids (NEAs) has increased in anticipation of the two sample-return missions that will reach their targets in the next four years and bring samples to the Earth within five years. Concurrently, the discovery of water ice on the surfaces of two primitive asteroids (24 Themis and 65 Cybele) placed the focus on the outer-belt (orbits with semi-major axis larger than 2.82 AU), where more asteroids could harbor water ice on, or below the surface.In 2010 we started a survey, called the PRIMitive Asteroids Spectroscopic Survey (PRIMASS), to collect spectra of primitive asteroids all through the Solar System. Up to now, PRIMASS library (PRIMASS-L) contains more than 530 spectra (0.4 - 2.5 μm) of primitive asteroids (> 90% of the asteroids had no spectroscopic data before) in the inner and outer belt. The aim of this survey is to provide the community with a comprehensive collection of data that enable us to study the surface composition of primitive asteroids by means of visible and near-infrared spectroscopy.Our plans for the close future include making PRIMASS-L publicly available in proper timing to be used by the teams of the OSIRIS-REx (NASA) and Hayabusa 2 (JAXA) missions. These missions will characterize two primitive near-Earth asteroids in detail, and the Earth-based libraries, as PRIMASS-L, will establish the broader framework and maximize the value of the spacecraft results. PRIMASS-L will also serve as a quality-check database for the Gaia spectroscopic products that will be published in its final release, by the end of the nominal mission in 2019.In parallel, we plan to continue observing at least for four more semesters (up to semester 2019A). After almost 10 years of data acquisition, the PRIMASS database will contain about 700 spectra of primitive asteroids

  8. Spectroscopic and chemometric exploration of food quality

    DEFF Research Database (Denmark)

    Pedersen, Dorthe Kjær

    2002-01-01

    The desire to develop non-invasive rapid measurements of essential quality parameters in foods is the motivation of this thesis. Due to the speed and noninvasive properties of spectroscopic techniques, they have potential as on-line or atline methods and can be employed in the food industry...... in order to control the quality of the end product and to continuously monitor the production. In this thesis, the possibilities and limitations of the application of spectroscopy and chemometrics in rapid control of food quality are discussed and demonstrated by the examples in the eight included...... publications. Different aspects of food quality are covered, but the focus is mainly on the development of multivariate calibrations for predictions of rather complex attributes such as the water-holding capacity of meat, ethical quality of the slaughtering procedure, protein content of single wheat kernels...

  9. Spectroscopic Investigation of the Mechanism of Photocatalysis

    Directory of Open Access Journals (Sweden)

    Yoshio Nosaka

    2014-11-01

    Full Text Available Reaction mechanisms of various kinds of photocatalysts have been reviewed based on the recent reports, in which various spectroscopic techniques including luminol chemiluminescence photometry, fluorescence probe method, electron spin resonance (ESR, and nuclear magnetic resonance (NMR spectroscopy were applied. The reaction mechanisms elucidated for bare and modified TiO2 were described individually. The modified visible light responsive TiO2 photocatalysts, i.e., Fe(III-deposited metal-doped TiO2 and platinum complex-deposited TiO2, were studied by detecting paramagnetic species with ESR, •O2− (or H2O2 with chemiluminescence photometry, and OH radicals with a fluorescence probe method. For bare TiO2, the difference in the oxidation mechanism for the different crystalline form was investigated by the fluorescence probe method, while the adsorption and decomposition behaviors of several amino acids and peptides were investigated by 1H-NMR spectroscopy.

  10. Raman spectroscopic biochemical mapping of tissues

    Science.gov (United States)

    Stone, Nicholas; Hart Prieto, Maria C.; Kendall, Catherine A.; Shetty, Geeta; Barr, Hugh

    2006-02-01

    Advances in technologies have brought us closer to routine spectroscopic diagnosis of early malignant disease. However, there is still a poor understanding of the carcinogenesis process. For example it is not known whether many cancers follow a logical sequence from dysplasia, to carcinoma in situ, to invasion. Biochemical tissue changes, triggered by genetic mutations, precede morphological and structural changes. These can be probed using Raman or FTIR microspectroscopy and the spectra analysed for biochemical constituents. Local microscopic distribution of various constituents can then be visualised. Raman mapping has been performed on a number of tissues including oesophagus, breast, bladder and prostate. The biochemical constituents have been calculated at each point using basis spectra and least squares analysis. The residual of the least squares fit indicates any unfit spectral components. The biochemical distribution will be compared with the defined histopathological boundaries. The distribution of nucleic acids, glycogen, actin, collagen I, III, IV, lipids and others appear to follow expected patterns.

  11. Nondestructive spectroscopic characterization of building materials

    Science.gov (United States)

    Kassu, Aschalew; Walker, Lauren; Sanders, Rachel; Farley, Carlton; Mills, Jonathan; Sharma, Anup

    2017-04-01

    The purpose of this research project is to demonstrate the application of Raman spectroscopy technique for characterization and identification of the distinct Raman signatures of construction materials. The results reported include the spectroscopic characterization of building materials using compact Raman system with 785 nm wavelength laser. The construction materials studied include polyblend sanded grout, fire barrier sealant, acrylic latex caulk plus and white silicone. It is found that, both fire barrier sealant and acrylic latex caulk plus has a prominent Raman band at 1082 cm-1, and three minor Raman signatures located at 275, 706 and 1436 cm-1. On the other hand, sand grout has three major Raman bands at 1265, 1368 and 1455 cm-1, and four minor peaks at 1573, 1683, 1762, and 1868 cm-1. White silicone, which is a widely used sealant material in construction industry, has two major Raman bands at 482 and 703 cm-1, and minor Raman characteristic bands at 783 and 1409 cm-1.

  12. Micron scale spectroscopic analysis of materials

    International Nuclear Information System (INIS)

    James, David; Finlayson, Trevor; Prawer, Steven

    1991-01-01

    The goal of this proposal is the establishment of a facility which will enable complete micron scale spectroscopic analysis of any sample which can be imaged in the optical microscope. Current applications include studies of carbon fibres, diamond thin films, ceramics (zirconia and high T c superconductors), semiconductors, wood pulp, wool fibres, mineral inclusions, proteins, plant cells, polymers, fluoride glasses, and optical fibres. The range of interests crosses traditional discipline boundaries and augurs well for a truly interdisciplinary collaboration. Developments in instrumentation such as confocal imaging are planned to achieve sub-micron resolution, and advances in computer software and hardware will enable the aforementioned spectroscopies to be used to map molecular and crystalline phases on the surfaces of materials. Coupled with existing compositional microprobes (e.g. the proton microprobe) the possibilities for the development of new, powerful, hybrid imaging technologies appear to be excellent

  13. Search for planets by spectroscopic methods

    Science.gov (United States)

    Serkowski, K.

    1980-01-01

    Spectroscopic means of detecting the motion of a star around a star-planet barycenter are considered. The precision of such an observation, which requires a radial velocity error of not more than 5 m/sec, is discussed in relation to the spectral resolutions of the detectors utilized. The University of Arizona radial velocity spectrometer is then presented, with particular attention given to the location of the absorption cell in a beam of light from an incandescent bulb, high-accuracy wavelength calibration involving the use of a Fabry-Perot interferometer in front of an echelle spectrograph, and future plans for the use of light reflected from a Fabry-Perot etalon to improve transmittance. On the basis of these techniques, it is expected that radial velocities with accuracies sufficient for the detection of extrasolar planets will be obtained.

  14. Spectroscopic study of natural quartz samples

    International Nuclear Information System (INIS)

    Nunes, Eduardo H.M.; Lameiras, Fernando S.; Houmard, Manuel; Vasconcelos, Wander L.

    2013-01-01

    In this work we performed a spectroscopic characterization of natural amethyst, citrine, and prasiolite samples from different localities. These materials were examined by X-ray powder diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), UV–visible spectroscopy (UV–vis), electron paramagnetic resonance (EPR), and inductively coupled plasma atomic emission spectrometry (ICP-AES). Samples were used in this study in as-received, gamma-irradiated, UV-irradiated, and heat-treated conditions. We observed the changes in the FTIR, UV–vis, and EPR spectra of these samples as a function of the condition they were analyzed. We noticed that gamma radiation had a great effect on the color of amethyst and citrine samples used in this work. It was observed that light colored samples showed a deepening of their colors upon gamma-irradiation and a bleaching upon heat treatment at 450 °C. However, we observed that gamma radiation had a slight effect on the color of citrine. UV-irradiations revealed that the coloration of both amethyst and prasiolite can be bleached by UV radiation. On the other hand, the color of citrine was not affected by UV radiation. - Highlights: • Spectroscopic characterization of natural amethyst, citrine, and prasiolite samples. • Gamma radiation had a great effect on the color of amethyst and citrine samples. • The coloration of citrine was not affected by UV radiation. • Resonance lines observed in EPR spectra of some samples were associated to Fe 3+ . • Broad resonance signal observed in EPR spectra of citrine samples

  15. The HITRAN2016 molecular spectroscopic database

    Science.gov (United States)

    Gordon, I. E.; Rothman, L. S.; Hill, C.; Kochanov, R. V.; Tan, Y.; Bernath, P. F.; Birk, M.; Boudon, V.; Campargue, A.; Chance, K. V.; Drouin, B. J.; Flaud, J.-M.; Gamache, R. R.; Hodges, J. T.; Jacquemart, D.; Perevalov, V. I.; Perrin, A.; Shine, K. P.; Smith, M.-A. H.; Tennyson, J.; Toon, G. C.; Tran, H.; Tyuterev, V. G.; Barbe, A.; Császár, A. G.; Devi, V. M.; Furtenbacher, T.; Harrison, J. J.; Hartmann, J.-M.; Jolly, A.; Johnson, T. J.; Karman, T.; Kleiner, I.; Kyuberis, A. A.; Loos, J.; Lyulin, O. M.; Massie, S. T.; Mikhailenko, S. N.; Moazzen-Ahmadi, N.; Müller, H. S. P.; Naumenko, O. V.; Nikitin, A. V.; Polyansky, O. L.; Rey, M.; Rotger, M.; Sharpe, S. W.; Sung, K.; Starikova, E.; Tashkun, S. A.; Auwera, J. Vander; Wagner, G.; Wilzewski, J.; Wcisło, P.; Yu, S.; Zak, E. J.

    2017-12-01

    This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is composed of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 300 additional molecules important in different areas of atmospheric science have been added to the database. The compilation can be accessed through www.hitran.org. Most of the HITRAN data have now been cast into an underlying relational database structure that offers many advantages over the long-standing sequential text-based structure. The new structure empowers the user in many ways. It enables the incorporation of an extended set of fundamental parameters per transition, sophisticated line-shape formalisms, easy user-defined output formats, and very convenient searching, filtering, and plotting of data. A powerful application programming interface making use of structured query language (SQL) features for higher-level applications of HITRAN is also provided.

  16. Spectroscopic neutron detection using composite scintillators

    Science.gov (United States)

    Jovanovic, I.; Foster, A.; Kukharev, V.; Mayer, M.; Meddeb, A.; Nattress, J.; Ounaies, Z.; Trivelpiece, C.

    2016-09-01

    Shielded special nuclear material (SNM), especially highly enriched uranium, is exceptionally difficult to detect without the use of active interrogation (AI). We are investigating the potential use of low-dose active interrogation to realize simultaneous high-contrast imaging and photofission of SNM using energetic gamma-rays produced by low-energy nuclear reactions, such as 11B(d,nγ)12C and 12C(p,p‧)12C. Neutrons produced via fission are one reliable signature of the presence of SNM and are usually identified by their unique timing characteristics, such as the delayed neutron die-away. Fast neutron spectroscopy may provide additional useful discriminating characteristics for SNM detection. Spectroscopic measurements can be conducted by recoil-based or thermalization and capture-gated detectors; the latter may offer unique advantages since they facilitate low-statistics and event-by-event neutron energy measurements without spectrum unfolding. We describe the results of the development and characterization of a new type of capture-gated spectroscopic neutron detector based on a composite of scintillating polyvinyltoluene and lithium-doped scintillating glass in the form of millimeter-thick rods. The detector achieves >108 neutron-gamma discrimination resulting from its geometric properties and material selection. The design facilitates simultaneous pulse shape and pulse height discrimination, despite the fact that no materials intrinsically capable of pulse shape discrimination have been used to construct the detector. Accurate single-event measurements of neutron energy may be possible even when the energy is relatively low, such as with delayed fission neutrons. Simulation and preliminary measurements using the new composite detector are described, including those conducted using radioisotope sources and the low-dose active interrogation system based on low-energy nuclear reactions.

  17. Raman spectroscopic identification of scytonemin and its derivatives as key biomarkers in stressed environments.

    Science.gov (United States)

    Varnali, Tereza; Edwards, Howell G M

    2014-12-13

    Raman spectroscopy has been identified as an important first-pass analytical technique for deployment on planetary surfaces as part of a suite of instrumentation in projected remote space exploration missions to detect extant or extinct extraterrestrial life signatures. Aside from the demonstrable advantages of a non-destructive sampling procedure and an ability to record simultaneously the molecular signatures of biological, geobiological and geological components in admixture in the geological record, the interrogation and subsequent interpretation of spectroscopic data from these experiments will be critically dependent upon the recognition of key biomolecular markers indicative of life existing or having once existed in extreme habitats. A comparison made with the characteristic Raman spectral wavenumbers obtained from standards is not acceptable because of shifts that can occur in the presence of other biomolecules and their host mineral matrices. In this paper, we identify the major sources of difficulty experienced in the interpretation of spectroscopic data centring on a key family of biomarker molecules, namely scytonemin and its derivatives; the parent scytonemin has been characterized spectroscopically in cyanobacterial colonies inhabiting some of the most extreme terrestrial environments and, with the support of theoretical calculations, spectra have been predicted for the characterization of several of its derivatives which could occur in novel extraterrestrial environments. This work will form the foundation for the identification of novel biomarkers and for their Raman spectroscopic discrimination, an essential step in the interpretation of potentially complex and hitherto unknown biological radiation protectants based on the scytoneman and scytonin molecular skeletons which may exist in niche geological scenarios in the surface and subsurface of planets and their satellites in our Solar System. © 2014 The Author(s) Published by the Royal Society

  18. A comparison of microscopic and spectroscopic identification methods for analysis of microplastics in environmental samples.

    Science.gov (United States)

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon

    2015-04-15

    The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (microplastics were significantly (p0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Tomographic separation of composite spectra - The components of the O-star spectroscopic binary AO Cassiopeiae

    Science.gov (United States)

    Bagnuolo, William G., Jr.; Gies, Douglas R.

    1991-01-01

    The UV photospheric lines of the short-period, double-lined O-star spectroscopic binary AO Cas are analyzed. Archival data from IUE (16 spectra uniformly distributed in orbital phase) were analyzed with a tomography algorithm to produce the separate spectra of the two stars in six spectral regions. The spectral classifications of the primary and secondary, O9.5 III and O8 V, respectively, were estimated through a comparison of UV line ratios with those in spectral standard stars. An intensity ratio of 0.5-0.7 (primary brighter) at 1600 A is compatible with the data.

  20. Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

    Science.gov (United States)

    Soller, Babs R.; Idwasi, Patrick O.; Balaguer, Jorge; Levin, Steven; Simsir, Sinan A.; Vander Salm, Thomas J.; Collette, Helen; Heard, Stephen O.

    2003-01-01

    OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and

  1. Some experiences with absorption, phonon Raman, and luminescence spectroscopic probes of crystal structure of f-element compounds

    International Nuclear Information System (INIS)

    Peterson, J.R.

    1992-01-01

    Structural information is crucial to the study and understanding of the basic chemical properties of the f elements. X-ray diffraction (XRD) techniques are usually used to obtain crystal structure information. However, the transuranium (5f) elements, because of their radioactivity and limited availability, present problems for standard XRD analysis. For some time now we have been developing and using various spectroscopic probes of crystal structure; an overview of our research in this area is presented here

  2. Frequency standards

    CERN Document Server

    Riehle, Fritz

    2006-01-01

    Of all measurement units, frequency is the one that may be determined with the highest degree of accuracy. It equally allows precise measurements of other physical and technical quantities, whenever they can be measured in terms of frequency.This volume covers the central methods and techniques relevant for frequency standards developed in physics, electronics, quantum electronics, and statistics. After a review of the basic principles, the book looks at the realisation of commonly used components. It then continues with the description and characterisation of important frequency standards

  3. 2-d spectroscopic imaging of brain tumours

    International Nuclear Information System (INIS)

    Ferris, N.J.; Brotchie, P.R.

    2002-01-01

    Full text: This poster illustrates the use of two-dimensional spectroscopic imaging (2-D SI) in the characterisation of brain tumours, and the monitoring of subsequent treatment. After conventional contrast-enhanced MR imaging of patients with known or suspected brain tumours, 2-D SI is performed at a single axial level. The level is chosen to include the maximum volume of abnormal enhancement, or, in non-enhancing lesions. The most extensive T2 signal abnormality. Two different MR systems have been used (Marconi Edge and GE Signa LX); at each site, a PRESS localisation sequence is employed with TE 128-144 ms. Automated software is used to generate spectral arrays, metabolite maps, and metabolite ratio maps from the spectroscopic data. Colour overlays of the maps onto anatomical images are produced using manufacturer software or the Medex imaging data analysis package. High grade gliomas showed choline levels higher than those in apparently normal brain, with decreases in NAA and creatine. Some lesions showed spectral abnormality extending into otherwise normal appearing brain. This was also seen in a case of CNS lymphoma. Lowgrade lesions showed choline levels similar to normal brain, but with decreased NAA. Only a small number of metastases have been studied, but to date no metastasis has shown spectral abnormality beyond the margins suggested by conventional imaging. Follow-up studies generally show spectral heterogeneity. Regions with choline levels higher than those in normal-appearing brain are considered to represent recurrent high-grade tumour. Some regions show choline to be the dominant metabolite, but its level is not greater than that seen in normal brain. These regions are considered suspicious for residual / recurrent tumour when the choline / creatine ratio exceeds 2 (lower ratios may represent treatment effect). 2-D SI improves the initial assessment of brain tumours, and has potential for influencing the radiotherapy treatment strategy. 2-D SI also

  4. Study of interaction of butyl p-hydroxybenzoate with human serum albumin by molecular modeling and multi-spectroscopic method

    Energy Technology Data Exchange (ETDEWEB)

    Wang Qin, E-mail: wqing07@lzu.c [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Zhang Yaheng, E-mail: zhangyah04@lzu.c [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Sun Huijun, E-mail: sun.hui.jun-04@163.co [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Chen Hongli, E-mail: hlchen@lzu.edu.c [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Chen Xingguo, E-mail: chenxg@lzu.edu.c [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China)

    2011-02-15

    Study of the interaction between butyl p-hydroxybenzoate (butoben) and human serum albumin (HSA) has been performed by molecular modeling and multi-spectroscopic method. The interaction mechanism was predicted through molecular modeling first, then the binding parameters were confirmed using a series of spectroscopic methods, including fluorescence spectroscopy, UV-visible absorbance spectroscopy, circular dichroism (CD) spectroscopy and Fourier transform infrared (FT-IR) spectroscopy. The thermodynamic parameters of the reaction, standard enthalpy {Delta}H{sup 0} and entropy {Delta}S{sup 0}, have been calculated to be -29.52 kJ mol{sup -1} and -24.23 J mol{sup -1} K{sup -1}, respectively, according to the Van't Hoff equation, which suggests the van der Waals force and hydrogen bonds are the predominant intermolecular forces in stabilizing the butoben-HSA complex. Results obtained by spectroscopic methods are consistent with that of the molecular modeling study. In addition, alteration of secondary structure of HSA in the presence of butoben was evaluated using the data obtained from UV-visible absorbance, CD and FT-IR spectroscopies. - Research highlights: The interaction between butyl p-hydroxybenzoate with HSA has been investigated for the first time. Molecular modeling study can provide theoretical direction for experimental design. Multi-spectroscopic method can provide the binding parameters and thermodynamic parameters. These results are important for food safety and human health when using parabens as a preservative.

  5. Raman spectroscopic study of some chalcopyrite-xanthate flotation products

    CSIR Research Space (South Africa)

    Andreev, GN

    2003-12-16

    Full Text Available of normal vibrations of the corresponding individual compounds. The latter facilitated the Raman spectroscopic elucidation of the reaction products formed on the chalcopyrite surface in real industrial flotation conditions with a sodium isopropyl xanthate...

  6. Synthesis and spectroscopic analysis of Schiff Bases of Imesatin ...

    African Journals Online (AJOL)

    Synthesis and spectroscopic analysis of Schiff Bases of Imesatin and Isatin derivatives. Olubunmi S. Oguntoye, Abdulmumeen A. Hamid, Gabriel S. Iloka, Sunday O. Bodede, Samson O. Owalude, Adedibu C. Tella ...

  7. Infrared spectroscopy and spectroscopic imaging in forensic science.

    Science.gov (United States)

    Ewing, Andrew V; Kazarian, Sergei G

    2017-01-16

    Infrared spectroscopy and spectroscopic imaging, are robust, label free and inherently non-destructive methods with a high chemical specificity and sensitivity that are frequently employed in forensic science research and practices. This review aims to discuss the applications and recent developments of these methodologies in this field. Furthermore, the use of recently emerged Fourier transform infrared (FT-IR) spectroscopic imaging in transmission, external reflection and Attenuated Total Reflection (ATR) modes are summarised with relevance and potential for forensic science applications. This spectroscopic imaging approach provides the opportunity to obtain the chemical composition of fingermarks and information about possible contaminants deposited at a crime scene. Research that demonstrates the great potential of these techniques for analysis of fingerprint residues, explosive materials and counterfeit drugs will be reviewed. The implications of this research for the examination of different materials are considered, along with an outlook of possible future research avenues for the application of vibrational spectroscopic methods to the analysis of forensic samples.

  8. Synthesis, Spectroscopic Properties and DFT Calculation of Novel ...

    Indian Academy of Sciences (India)

    L1) identifies its molecular structure and reveals π-π stacking. The synthetic mechanisms for L2, L3 were studied by density functional theory calculations. And a comprehensive study of spectroscopic properties involving experimental data and ...

  9. A COMPARISON OF GALAXY COUNTING TECHNIQUES IN SPECTROSCOPICALLY UNDERSAMPLED REGIONS

    International Nuclear Information System (INIS)

    Specian, Mike A.; Szalay, Alex S.

    2016-01-01

    Accurate measures of galactic overdensities are invaluable for precision cosmology. Obtaining these measurements is complicated when members of one’s galaxy sample lack radial depths, most commonly derived via spectroscopic redshifts. In this paper, we utilize the Sloan Digital Sky Survey’s Main Galaxy Sample to compare seven methods of counting galaxies in cells when many of those galaxies lack redshifts. These methods fall into three categories: assigning galaxies discrete redshifts, scaling the numbers counted using regions’ spectroscopic completeness properties, and employing probabilistic techniques. We split spectroscopically undersampled regions into three types—those inside the spectroscopic footprint, those outside but adjacent to it, and those distant from it. Through Monte Carlo simulations, we demonstrate that the preferred counting techniques are a function of region type, cell size, and redshift. We conclude by reporting optimal counting strategies under a variety of conditions.

  10. ITER perspective on fusion reactor diagnostics - A spectroscopic view

    DEFF Research Database (Denmark)

    De Bock, M. F. M.; Barnsley, R.; Bassan, M.

    2016-01-01

    challenges to the development of spectroscopic (but also other) diagnostics. This contribution presents an overview of recent achievements in 4 topical areas: First mirror protection and cleaning, Nuclear confinement, Radiation mitigation strategy for optical and electronic components and Calibration...

  11. Synthesis, spectroscopic and DFT characterization of 4 β -(4- tert ...

    African Journals Online (AJOL)

    Synthesis, spectroscopic and DFT characterization of 4 β -(4-tert-butylphenoxy) phthalocyanine positional isomers for non-linear optical absorption. Denisha Gounden, Grace N. Ngubeni, Marcel S. Louzada, Samson Khene, Jonathan Britton, Nolwazi Nombona ...

  12. Relevant Standards

    Indian Academy of Sciences (India)

    .86: Ethernet over LAPS. Standard in China and India. G.7041: Generic Framing Procedure (GFP). Supports Ethernet as well as other data formats (e.g., Fibre Channel); Protocol of ... IEEE 802.3x for flow control of incoming Ethernet data ...

  13. [Spectroscopic characteristics of novel Psidium meroterpenoids isolated from guava leaves].

    Science.gov (United States)

    Ouyang, Wen; Zhu, Xiao-ai; Liu, Xiao-juan; Yie, Shu-min; Zhao, Litchao; Su, Lei; Cao, Yong

    2015-07-01

    Recently, novel Psidium meroterpenoids were reported in the guava leaves. According to careful analysis of the spectral data of literatures, the spectroscopic characteristics and biosynthetic pathway of Psidium meroterpenoids were summarized in this paper. The results showed that Psidium meroterpenoids had distinct spectroscopic features and reasonable biosynthetic routines, however the number order of carbon atoms was not consistent in the reported literatures. It was concluded that Psidium meroterpenoids were the characteristic chemical constituents of Psidium guajava Linn.

  14. Acquisition of Infrared Variable Angle Spectroscopic Ellipsometer (IR-VASE)

    Science.gov (United States)

    2016-04-22

    SECURITY CLASSIFICATION OF: This award was used to acquire a J.A. Woollam Infrared Variable Angle Spectroscopic Ellipsometer ( IR -VASE). The IR -VASE...unit is capable of obtaining crucial IR information of ultrathin films whilst being complemented with ellipsometry data. This powerful and versatile...Unlimited UU UU UU UU 22-04-2016 1-Feb-2015 31-Jan-2016 Final Report: Acquisition of Infrared Variable Angle Spectroscopic Ellipsometer ( IR -VASE) The

  15. Whispering Gallery Optical Resonator Spectroscopic Probe and Method

    Science.gov (United States)

    Anderson, Mark S. (Inventor)

    2014-01-01

    Disclosed herein is a spectroscopic probe comprising at least one whispering gallery mode optical resonator disposed on a support, the whispering gallery mode optical resonator comprising a continuous outer surface having a cross section comprising a first diameter and a second diameter, wherein the first diameter is greater than the second diameter. A method of measuring a Raman spectrum and an Infra-red spectrum of an analyte using the spectroscopic probe is also disclosed.

  16. Theoretical predictions for alpha particle spectroscopic strengths

    International Nuclear Information System (INIS)

    Draayer, J.P.

    1975-01-01

    Multinucleon transfers induced in heavy-ion reactions of the type ( 6 Li,d) furnish a selective probe with which to study the interplay between rotational and clustering phenomena so characteristic of the structure of the light sd-shell nuclei. For these nuclei, theoretical predictions for inter-band as well as intra-band transfer strengths can be made using recently tabulated results for angular momentum dependent SU 3 inclusion R 3 relative spectroscopic strengths and angular momentum independent SU 6 inclusion SU 3 coefficients of fractional parentage. The pure SU 3 (oscillator)-SU 4 (supermultiplet) symmetry limit agrees well with results obtained using available eigenfunctions determined in large shell model calculations. In particular, the scalar nature of a transferred ''alpha''-cluster insures that the effect of spatial symmetry admixtures in the initial and final states of the target and residual nuclei are minimized. Sum rule quantities provide a measure of the probable effects of symmetry breaking. Strength variations within a band are expected; transfers to core excited states are often favored. Results extracted from exact finite range DWBA analyses of ( 6 Li,d) data on 16 , 18 O, 20 , 21 , 22 Ne, 24 , 25 Mg show some anomalies in our understanding of the structure and/or reaction mechanisms. (18 figures) (U.S.)

  17. Spectroscopic study of ohmically heated Tokamak discharges

    International Nuclear Information System (INIS)

    Breton, C.; Michelis, C. de; Mattioli, M.

    1980-07-01

    Tokamak discharges interact strongly with the wall and/or the current aperture limiter producing recycling particles, which penetrate into the discharge and which can be studied spectroscopically. Working gas (hydrogen or deuterium) is usually studied observing visible Balmer lines at several toroidal locations. Absolute measurements allow to obtain both the recycling flux and the global particle confinement time. With sufficiently high resolution the isotopic plasma composition can be obtained. The impurity elements can be divided into desorbed elements (mainly oxygen) and eroded elements (metals from both walls and limiter) according to the plasma-wall interaction processes originating them. Space-and time-resolved emission in the VUV region down to about 20 A will be reviewed for ohmically-heated discharges. The time evolution can be divided into four phases, not always clearly separated in a particular discharge: a) the initial phase, lasting less than 10 ms (the so-called burn-out phase), b) the period of increasing plasma current and electron temperature, lasting typically 10 - 100 ms, c) an eventual steady state (plateau of the plasma current with almost constant density and temperature), d) the increase of the electron density up to or just below the maximum value attainable in a given device. For all these phases the results reported from different devices will be described and compared

  18. HEXA: a machine for spectroscopic cartography

    Science.gov (United States)

    Barrado, D.; Aceituno, J.; Galadí, D.; Iglesias-Páramo, J.; Sánchez, S. F.

    2013-05-01

    We have performed a conceptual and viability study for HEXA, a 6.5 m aperture, wide-field telescope, with high multiplexing factor, framed in the strategic plan for the Calar Alto observatory in 2014-2018 and beyond, centred on the scientific cases arisen from the current need for wide-field spectroscopic surveys with very large multiplexing capability. The baseline design considers a field-of-view of 1.5°, multiplexing factor around or over 500 and possible spectral resolutions in the interval R = 5000 - 50 000, with instruments placed on two Nasmyth platforms. Other variants are also considered, including Ritchey-Chrétien and prime-focus solutions. The telescope concept is described, together with the instruments that have already undergone, or that are still undergoing, the conceptual design process: CEO, an innovative Imaging Fourier Transform spectrograph. GEA, a Gaia-inspired drift-scanning slitless spectrograph. BRONTESS, a fast and simple camera for guiding and ToO work. A PMAS-based multi-IFU, highly multiplexed spectrograph. And the multi-fibre spectrograph GYGES. Some of the instrument concepts analysed are based on the versatile fiber-positioner HECATE (with a minimum of 361 positioners). Some of the fibre-based instruments would allow, too, fibres entering a battery of CAF{É}-type high-res spectrographs.

  19. Spectroscopic characterization of alkaline earth uranyl carbonates

    International Nuclear Information System (INIS)

    Amayri, Samer; Reich, Tobias; Arnold, Thuro; Geipel, Gerhard; Bernhard, Gert

    2005-01-01

    A series of alkaline uranyl carbonates, M[UO 2 (CO 3 ) 3 ].nH 2 O (M=Mg 2 , Ca 2 , Sr 2 , Ba 2 , Na 2 Ca, and CaMg) was synthesized and characterized by inductively coupled plasma mass spectrometry (ICP-MS) and atomic absorption spectrometry (AAS) after nitric acid digestion, X-ray powder diffraction (XRD), and thermal analysis (TGA/DTA). The molecular structure of these compounds was characterized by extended X-ray absorption fine-structure (EXAFS) spectroscopy and X-ray photoelectron spectroscopy (XPS). Crystalline Ba 2 [UO 2 (CO 3 ) 3 ].6H 2 O was obtained for the first time. The EXAFS analysis showed that this compound consists of (UO 2 )(CO 3 ) 3 clusters similar to the other alkaline earth uranyl carbonates. The average U-Ba distance is 3.90+/-0.02A.Fluorescence wavelengths and life times were measured using time-resolved laser-induced fluorescence spectroscopy (TRLFS). The U-O bond distances determined by EXAFS, TRLFS, XPS, and Raman spectroscopy agree within the experimental uncertainties. The spectroscopic signatures observed could be useful for identifying uranyl carbonate species adsorbed on mineral surfaces

  20. Spectroscopic Observation of CS_2 Dimer

    Science.gov (United States)

    Rezaei, M.; Oliaee, J. Norooz; Moazzen-Ahmadi, N.; McKellar, A. R. W.

    2011-06-01

    Infrared spectra of the CS_2 dimer are observed in the region of the CS_2 ν_3 fundamental band (˜ 1535 Cm-1) using a tuneable diode laser spectrometer. The weakly-bound complex is formed in a pulsed supersonic slit-jet expansion of a dilute gas mixture of carbon disulfide in helium. Contrary to the planar slipped-parallel geometry previously observed for (CO_2)_2, (N_2O)_2 and (OCS)_2, the CS_2 dimer exhibits a cross-shaped structure with D2d symmetry. Two bands were observed and analyzed: the fundamental (C-S asymmetric stretch) and a combination involving this mode plus an intermolecular vibration. In both cases, the rotational structure corresponds to a perpendicular (Δ K = ± 1) band of a symmetric rotor molecule. The intermolecular center of mass separation (C-C distance) is determined to be 3.539(7) {Å}. Thanks to symmetry, this is the only parameter required to characterize the structure, if the monomer geometry is assumed to remain unchanged in the dimer. From the band centers of the fundamental and combination band an intermolecular frequency of 10.96 Cm-1 is obtained, which we assign as the torsional bending mode. This constitutes the first high resolution spectroscopic investigation of CS_2 dimer.

  1. The BAT AGN Spectroscopic Survey (BASS)

    Science.gov (United States)

    Koss, Michael

    2017-08-01

    We present the Swift BAT AGN Spectroscopic Survey (BASS) and discus the first four papers. The catalog represents an unprecedented census of hard-X-ray selected AGN in the local universe, with ~90% of sources at zBAT catalog, we analyze a total of 1279 optical spectra, taken from twelve different telescopes, for a total of 642 spectra of unique AGN. We present the absorption and emission line measurements as well as black hole masses and accretion rates for the majority of obscured and un-obscured AGN (473), representing more than a factor of 10 increase from past studies. Consistent with previous surveys, we find an increase in the fraction of un-obscured (type 1) AGN, as measured from broad Hbeta and Halpha, with increasing 14-195 keV and 2-10 keV luminosity. We find the FWHM of the emission lines to show broad agreement with the X-ray obscuration measurements. Compared to narrow line AGN in the SDSS, the X-ray selected AGN in our sample with emission lines have a larger fraction of dustier galaxies suggesting these types of galaxies are missed in optical AGN surveys using emission line diagnostics.

  2. How spectroscopic ellipsometry can aid graphene technology?

    Energy Technology Data Exchange (ETDEWEB)

    Losurdo, Maria, E-mail: maria.losurdo@cnr.it; Giangregorio, Maria M.; Bianco, Giuseppe V.; Capezzuto, Pio; Bruno, Giovanni

    2014-11-28

    We explore the effects of substrate, grain size, oxidation and cleaning on the optical properties of chemical vapor deposited polycrystalline monolayer graphene exploiting spectroscopic ellipsometry in the NIR-Vis–UV range. Both Drude–Lorentz oscillators' and point-by-point fit approaches are used to analyze the ellipsometric spectra. For monolayer graphene, since anisotropy cannot be resolved, an isotropic model is used. A prominent absorption peak at approximately 4.8 eV, which is a mixture of π–π* interband transitions at the M-point of the Brillouin zone and of the π-plasmonic excitation, is observed. We discuss the sensitivity of this peak to the structural and cleaning quality of graphene. The comparison with previous published dielectric function spectra of graphene is discussed giving a rationale for the observed differences. - Highlights: • Optical properties of graphene are determined by ellipsometry on copper and on glass. • Optical spectra reveal the cleaning quality of transferred graphene. • Sensitivity of absorption peak to graphene structural quality is proven. • Optical properties are proven to be sensitive to oxidation of graphene. • Electronic interaction with substrate affects graphene optical properties.

  3. Herschel spectroscopic observations of PPNe and PNe

    Science.gov (United States)

    García-Lario, Pedro; Ramos-Medina, J.; Sánchez-Contreras, C.

    2017-10-01

    We are building a catalogue of interactively reprocessed observations of evolved stars observed with Herschel. The catalogue will offer not only the PACS and SPIRE spectroscopic data for each observation, but also complementary information from other infrared space observatories. As a first step, we are concentrating our efforts on two main activities: 1) the interactive data-reduction of more than 500 individual spectra obtained with PACS in the 55-210 μm range, available in the Herschel Science Archive; 2) the creation of a catalogue, accesible via a web-based interface and through the Virtual Observatory. Our ultimate goal is to carry out a comprehensive and systematic study of the far infrared properties of low-and intermediate-mass evolved stars using these data and enable science based on Herschel archival data. The objects cover the whole range of possible evolutionary stages in this short-lived phase of stellar evolution, from the AGB to the PN stage, displaying a wide variety of chemical and physical properties.

  4. Galaxy Evolution Spectroscopic Explorer: Scientific Rationale

    Science.gov (United States)

    Heap, Sara; Ninkov, Zoran; Robberto, Massimo; Hull, Tony; Purves, Lloyd

    2016-01-01

    GESE is a mission concept consisting of a 1.5-m space telescope and UV multi-object slit spectrograph designed to help understand galaxy evolution in a critical era in the history of the universe, where the rate of star-formation stopped increasing and started to decline. To isolate and identify the various processes driving the evolution of these galaxies, GESE will obtain rest-frame far-UV spectra of 100,000 galaxies at redshifts, z approximately 1-2. To obtain such a large number of spectra, multiplexing over a wide field is an absolute necessity. A slit device such as a digital micro-mirror device (DMD) or a micro-shutter array (MSA) enables spectroscopy of a hundred or more sources in a single exposure while eliminating overlapping spectra of other sources and blocking unwanted background like zodiacal light. We find that a 1.5-m space telescope with a MSA slit device combined with a custom orbit enabling long, uninterrupted exposures (approximately 10 hr) are optimal for this spectroscopic survey. GESE will not be operating alone in this endeavor. Together with x-ray telescopes and optical/near-IR telescopes like Subaru/Prime Focus Spectrograph, GESE will detect "feedback" from young massive stars and massive black holes (AGN's), and other drivers of galaxy evolution.

  5. Spectroscopic Characterization of Omeprazole and Its Salts

    Directory of Open Access Journals (Sweden)

    Tomislav Vrbanec

    2017-01-01

    Full Text Available During drug development, it is important to have a suitable crystalline form of the active pharmaceutical ingredient (API. Mostly, the basic options originate in the form of free base, acid, or salt. Substances that are stable only within a certain pH range are a challenge for the formulation. For the prazoles, which are known to be sensitive to degradation in an acid environment, the formulation is stabilized with alkaline additives or with the application of API formulated as basic salts. Therefore, preparation and characterization of basic salts are needed to monitor any possible salinization of free molecules. We synthesized salts of omeprazole from the group of alkali metals (Li, Na, and K and alkaline earth metals (Mg, Ca. The purpose of the presented work is to demonstrate the applicability of vibrational spectroscopy to discriminate between the OMP and OMP-salt molecules. For this reason, the physicochemical properties of 5 salts were probed using infrared and Raman spectroscopy, NMR, TG, DSC, and theoretical calculation of vibrational frequencies. We found out that vibrational spectroscopy serves as an applicable spectroscopic tool which enables an accurate, quick, and nondestructive way to determine the characteristic of OMP and its salts.

  6. Soft tissue imaging with photon counting spectroscopic CT.

    Science.gov (United States)

    Shikhaliev, Polad M

    2015-03-21

    The purpose of this work was experimental investigation of photon counting spectroscopic CT (PCS-CT) imaging of anatomical soft tissue with clinically relevant size. The imaging experiments were performed using a spectroscopic CT system based on CdZnTe photon counting detector with two rows of pixels, 256 pixels in each row, 1  ×  1 mm(2) pixel size, and 25.6 cm detector length. The detector could split the x-ray energy spectrum to 5 regions (energy bins), and acquire 5 multi-energy (spectroscopic) CT images in a single CT scan. A sample of round shaped anatomical soft tissue of 14 cm diameter including lean and fat was used for imaging. To avoid the negative effect of anatomical noise on quantitative analysis, a spectroscopic CT phantom with tissue equivalent solid materials was used. The images were acquired at 60, 90, and 120 kVp tube voltages, and spectroscopic image series were acquired with 3 and 5 energy bins. Spectroscopic CT numbers were introduced and used to evaluate an energy selective image series. The anatomical soft tissue with 14 cm diameter was visualized with good quality and without substantial artifacts by the photon counting spectroscopic CT system. The effects of the energy bin crosstalk on spectroscopic CT numbers were quantified and analyzed. The single and double slice PCS-CT images were acquired and compared. Several new findings were observed, including the effect of soft tissue non-uniformity on image artifacts, unique status of highest energy bin, and material dependent visualization in spectroscopic image series. Fat-lean decomposition was performed using dual energy subtraction and threshold segmentation methods, and compared. Using K-edge filtered x-rays improved fat-lean decomposition as compared to conventional x-rays. Several new and important aspects of the PCS-CT were investigated. These include imaging soft tissue with clinically relevant size, single- and double-slice PCS-CT imaging, using spectroscopic CT

  7. Forming spectroscopic massive protobinaries by disc fragmentation

    Science.gov (United States)

    Meyer, D. M.-A.; Kuiper, R.; Kley, W.; Johnston, K. G.; Vorobyov, E.

    2018-01-01

    The surroundings of massive protostars constitute an accretion disc which has numerically been shown to be subject to fragmentation and responsible for luminous accretion-driven outbursts. Moreover, it is suspected to produce close binary companions which will later strongly influence the star's future evolution in the Hertzsprung-Russel diagram. We present three-dimensional gravitation-radiation-hydrodynamic numerical simulations of 100 M⊙ pre-stellar cores. We find that accretion discs of young massive stars violently fragment without preventing the (highly variable) accretion of gaseous clumps on to the protostars. While acquiring the characteristics of a nascent low-mass companion, some disc fragments migrate on to the central massive protostar with dynamical properties showing that its final Keplerian orbit is close enough to constitute a close massive protobinary system, having a young high- and a low-mass components. We conclude on the viability of the disc fragmentation channel for the formation of such short-period binaries, and that both processes - close massive binary formation and accretion bursts - may happen at the same time. FU-Orionis-type bursts, such as observed in the young high-mass star S255IR-NIRS3, may not only indicate ongoing disc fragmentation, but also be considered as a tracer for the formation of close massive binaries - progenitors of the subsequent massive spectroscopic binaries - once the high-mass component of the system will enter the main-sequence phase of its evolution. Finally, we investigate the Atacama Large (sub-)Millimeter Array observability of the disc fragments.

  8. Raman Spectroscopic Investigation of Dyes in Spices

    Science.gov (United States)

    Uhlemann, Ute; Ramoji, Anuradha; Rösch, Petra; Da Costa Filho, Paulo Augusto; Robert, Fabien; Popp, Jürgen

    2010-08-01

    In this study, a number of synthetic colorants for spices have been investigated by means of Raman spectroscopy, resonance Raman spectroscopy, and surface enhanced (resonance) Raman spectroscopy (SER(S)). The aim of the study was the determination of limits of detection for each dye separately and in binary mixtures of dyes in spiked samples of the spices. Most of the investigated dyes have been azo dyes, some being water-soluble, the other being fat-soluble. Investigating the composition of food preparations is an ongoing and important branch of analytical sciences. On one hand, new ingredients have to be analyzed with regard to their contents, on the other hand, raw materials that have been tampered have to be eliminated from food production processes. In the last decades, the various Raman spectroscopic methods have proven to be successful in many areas of life and materials sciences. The ability of Raman spectroscopy to distinguish even structural very similar analytes by means of their vibrational fingerprint will also be important in this study. Nevertheless, Raman scattering is a very weak process that is oftentimes overlaid by matrix interferences or fluorescence. In order to achieve limits of detection in the nanomolar range, the signal intensity has to be increased. According to the well-known equations, there are several ways of achieving this increase: •increasing sample concentration •increasing laser power •decreasing the laser wavelength •using electronic resonance •increasing the local electromagnetic field In this study, nearly all of the above-mentioned principles were applied. In a first step, all dyes were investigated in solution at different concentrations to determine a limit of detection. In the second step, spiked spice samples have been extracted with a variety of solvents and process parameters tested. To lower the limit of detection even further, SERS spectroscopy has been used as well in as out of electronic resonance.

  9. Flat-Fielding Solar Spectroscopic Images

    Science.gov (United States)

    Jones, H. P.

    1999-05-01

    A key problem for the analysis of the spectral-spatial datacubes produced by the many operational and planned solar spectroscopic imagers (e.g., SUMER and CDS on SOHO; the SOLIS Vector Spectromagnetograph (VSM)) is how to obtain a suitable "flat-field" image for fixed-pattern correction of each slice (long-slit spectrum) of the data. We describe here some algorithms developed for flat-fielding NASA/NSO Spectromagnetograph (SPM) and NSO Near-Infrared Magnograph (NIM 1) data both for analysis of He I 1083 nm data and as prototype procedures for the future VSM. The 1083 nm line is a severe test since the line is very weak, and similarly stringent requirements need to be met for precision spectral polarimetry from the VSM. The procedures remove spectrum lines from ``raw'' flat-fields derived by integrating spectra as the solar image is scanned to give an equivalent exposure to each spatial element along the spectrograph slit with the exact instrument configuration that is used in the observations. We find this preferable to other techniques such as moving the grating to nearby continuum or image defocussing, both of which change fringe patterns and/or the way optical impurities such as dust are imaged. An iterative fitting procedure is described which works well on the SPM data but is less satisfactory for NIM 1 because, in the latter case, the detector readout introduces a columnar pattern parallel to the spectrum lines which is removed by the SPM algorithm. The orientation of read-out and spectrum will be the same as NIM-1 for the VSM. We describe initial attempts to use a new least-squares spline technique (Thijsse, Hollanders, and Hendrikse, 1998, Computers in Physics 12, 393) to address this difficulty.

  10. Submillimeter Spectroscopic Study of Semiconductor Processing Plasmas

    Science.gov (United States)

    Helal, Yaser H.

    Plasmas used for manufacturing processes of semiconductor devices are complex and challenging to characterize. The development and improvement of plasma processes and models rely on feedback from experimental measurements. Current diagnostic methods are not capable of measuring absolute densities of plasma species with high resolution without altering the plasma, or without input from other measurements. At pressures below 100 mTorr, spectroscopic measurements of rotational transitions in the submillimeter/terahertz (SMM) spectral region are narrow enough in relation to the sparsity of spectral lines that absolute specificity of measurement is possible. The frequency resolution of SMM sources is such that spectral absorption features can be fully resolved. Processing plasmas are a similar pressure and temperature to the environment used to study astrophysical species in the SMM spectral region. Many of the molecular neutrals, radicals, and ions present in processing plasmas have been studied in the laboratory and their absorption spectra have been cataloged or are in the literature for the purpose of astrophysical study. Recent developments in SMM devices have made its technology commercially available for applications outside of specialized laboratories. The methods developed over several decades in the SMM spectral region for these laboratory studies are directly applicable for diagnostic measurements in the semiconductor manufacturing industry. In this work, a continuous wave, intensity calibrated SMM absorption spectrometer was developed as a remote sensor of gas and plasma species. A major advantage of intensity calibrated rotational absorption spectroscopy is its ability to determine absolute concentrations and temperatures of plasma species from first principles without altering the plasma environment. An important part of this work was the design of the optical components which couple 500 - 750 GHz radiation through a commercial inductively coupled plasma

  11. The SPHEREx All-Sky Spectroscopic Survey

    Science.gov (United States)

    Unwin, Stephen C.; SPHEREx Science Team, SPHEREx Project Team

    2016-06-01

    SPHEREx is a mission to conduct an optical-near-IR survey of the entire sky with a spectrum at every pixel location. It was selected by NASA for a Phase A study in its Small Explorer Program; if selected, development would begin in 2016, and the observatory would start a 2-year prime mission in 2020. An all-sky spectroscopic survey can be used to tackle a wide range of science questions. The SPHEREx science team is focusing on three: (1) Probing the physics of inflation through measuring non-Gaussianity from the study of large-scale structure; (2) Studying the origin of water and biogenic molecules in a wide range of physical and chemical environments via ice absorption spectra; (3) Charting the history of star formation in the universe through intensity mapping of the large-scale spatial power. The instrument is a small wide-field telescope operating in the range of 0.75 - 4.8 µm at a spectral resolution of 41.5 in the optical and 150 at the long-wavelength end. It observes in a sun-sync low-earth orbit, covering the sky like WISE and COBE. SPHEREx is a simple instrument that requires no new technology. The Phase A design has substantial technical and resource margins and can be built with low risk. It is a partnership between Caltech and JPL, with Ball Aerospace and the Korea Astronomy and Space Science Institute as major partners. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

  12. Spectroscopic modeling for tungsten EUV spectra

    International Nuclear Information System (INIS)

    Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Suzuki, Chihiro; Morita, Shigeru; Goto, Motoshi; Sasaki, Akira; Nakamura, Nobuyuki; Yamamoto, Norimasa; Koike, Fumihiro

    2014-01-01

    We have constructed an atomic model for tungsten extreme ultraviolet (EUV) spectra to reconstruct characteristic spectral feature of unresolved transition array (UTA) observed at 4-7 nm for tungsten ions. In the tungsten atomic modeling, we considered fine-structure levels with the quantum principal number n up to 6 as the atomic structure and calculated the electron-impact collision cross sections by relativistic distorted-wave method, using HULLAC atomic code. We measured tungsten EUV spectra in Large Helical Device (LHD) and Compact Electron Beam Ion Trap device (CoBIT) and compared them with the model calculation. The model successfully explain series of emission peaks at 1.5-3.5 nm as n=5-4 and 6-4 transitions of W 24+ - W 32+ measured in CoBIT and LHD and the charge state distributions were estimated for LHD plasma. The UTA feature observed at 4-7 nm was also successfully reconstructed with our model. The peak at ∼5 nm is produced mainly by many 4f-4d transition of W 22+ - W 35+ ions, and the second peak at ∼6 nm is produced by 4f-4d transition of W 25+ - W 28+ ions, and 4d-4p inner-shell transitions, 4p 5 4d n+1 - 4p 6 4d n , of W 29+ - W 35+ ions. These 4d-4p inner-shell transitions become strong since we included higher excited states such as 4p 5 4d n 4f state, which ADAS atomic data set does not include for spectroscopic modeling with fine structure levels. (author)

  13. A spectroscopic study of southern binary Cepheids

    Science.gov (United States)

    Petterson, O. K. L.; Albrow, Michael D.; Cottrell, P. L.; Fokin, A.

    2004-05-01

    High-resolution spectroscopic observations have been made of a number of southern binary Cepheids to determine their dynamical masses. The stars are part of a long-term program to observe southern variable starsf or which a valuable long-term database has been obtained. The most recent radial velocities have a precision of ~300 ms-1, allowing the detection of velocity differences of ~1 kms-1 with confidence. Masses were determined for three systems: the 9-day Cepheid S Mus (6.0±0.4 MSolar), the double-mode Cepheid Y Car (4.5±1.8 MSolar) and the 5-day Cepheid V350 Sgr (6.0±0.9 MSolar). For five Cepheids (YZ Car, AX Cir, V636 Sco, W Sgr and T Mon) new or improved orbital solutions were found. Line level effects have been observed in several species of lines. Most Cepheids were observed to show the same progression of line level effects. Using non-linear radiative hydrodynamical models, we have compared the results of these models with our observations. These have shown that AX Cir and YZ Car have the following properties: L = 2050 LSolar, M = 4.8 MSolar, Teff = 5900 K and L = 9350 LSolar, M = 7.7 MSolar, Teff = 5590 K. Our models show no strong shockwaves being produced. Good agreement was found between the observed and modelled spectral lines Fe I 5576Å, SiII 6347Å, BaII 5853Å and CaII 8542Å.

  14. Optical spectroscopic determination of human meniscus composition.

    Science.gov (United States)

    Ala-Myllymäki, Juho; Honkanen, Juuso T J; Töyräs, Juha; Afara, Isaac O

    2016-02-01

    This study investigates the correlation between the composition of human meniscus and its absorption spectrum in the visible (VIS) and near infrared (NIR) spectral range. Meniscus samples (n = 24) were obtained from nonarthritic knees of human cadavers with no history of joint diseases. Specimens (n = 72) were obtained from three distinct sections of the meniscus, namely; anterior, center, posterior. Absorption spectra were acquired from each specimen in the VIS and NIR spectral range (400-1,100 nm). Following spectroscopic probing, the specimens were subjected to biochemical analyses to determine the matrix composition, that is water, hydroxyproline, and uronic acid contents. Multivariate analytical techniques, including principal component analysis (PCA) and partial least squares (PLS) regression, were then used to investigate the correlation between the matrix composition and it spectral response. Our results indicate that the optical absorption of meniscus matrix is related to its composition, and this relationship is optimal in the NIR spectral range (750-1,100 nm). High correlations (R(2) (uronic)  = 86.9%, R(2) (water)  = 83.8%, R(2) (hydroxyproline)  = 81.7%, p meniscus composition, thus suggesting that spectral data in the NIR range can be utilized for estimating the matrix composition of human meniscus. In conclusion, optical spectroscopy, particularly in the NIR spectral range, is a potential method for evaluating the composition of human meniscus. This presents a promising technique for rapid and nondestructive evaluation of meniscus integrity in real-time during arthroscopic surgery. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Spectroscopic characterizations of organic/inorganic nanocomposites

    Science.gov (United States)

    Govani, Jayesh R.

    2009-12-01

    In the present study, pure and 0.3 wt%, 0.4 wt%, as well as 0.5 wt% L-arginine doped potassium dihydrogen phosphate (KDP) crystals were grown using solution growth techniques and further subjected to infrared (IR) absorption and Raman studies for confirmation of chemical group functionalization for investigating the incorporation mechanism of the L-arginine organic material into the KDP crystal structure. Infrared spectroscopic analysis suggests that structural changes are occurring for the L-arginine molecule as a result of its interaction with the KPD crystal. Infrared spectroscopic technique confirms the disturbance of the N-H, C-H and C-N bonds of the amino acid, suggesting successful incorporation of L-arginine into the KDP crystals. Raman analysis also reveals modification of the N-H, C-H and C-N bonds of the amino acid, implying successful inclusion of L-arginine into the KDP crystals. With the help of Gaussian software, a prediction of possible incorporation mechanisms of the organic material was obtained from comparison of the simulated infrared and Raman vibrational spectra with the experimental results. Furthermore, we also studied the effect of L-arginine doping on the thermal stability of the grown KDP crystal by employing Thermo gravimetric analysis (TGA). TGA suggests that increasing the level of L-arginine doping speeds the decomposition process and it weakens the KDP crystal, which indicates successful doping of the KDP crystals with L-arginine amino acid. Urinary stones are one of the oldest and most widely spread diseases in humans, animals and birds. Many remedies have been employed through the ages for the treatment of urinary stones. Recent medicinal measures reflect the modern advances, which are based on surgical removal, percutaneous techniques and extracorporeal shock wave lithotripsy (ESWL). Although these procedures are valuable, they are quite expensive for most people. Furthermore, recurrence of these diseases is awfully frequent with

  16. Spectroscopic survey of high-latitude fields and comparison to Galaxy models

    Energy Technology Data Exchange (ETDEWEB)

    Friel, E.D.

    1987-06-01

    The results of a spectroscopic survey of the stellar populations of high-Galactic latitude fields in SA 94 and Serpens are presented and analyzed. A set of six spectrophotometric indices is used to provide information on both the number and metallicity of evolved stars, while measurement of another 11 spectrophotometric indices provides an estimate of (Fe/H) good to 0.25 dex for the evolved stars identified in each field. A detailed comparison of the data with predictions of the standard Bahcall-Soneira Galaxy model reveals serious discrepancies. The properties of giants with roughly solar metallicity are described well by the disk giants predicted by the standard model. The sample is dominated by intermediate-metallicity giants whose properties are well described by a thick-disk component with scale height of approximately 700 pc that makes up about 5 percent of the solar neighborhood stellar density. 96 references.

  17. The protein circular dichroism data bank, a Web-based site for access to circular dichroism spectroscopic data.

    Science.gov (United States)

    Whitmore, Lee; Woollett, Benjamin; Miles, Andrew J; Janes, Robert W; Wallace, B A

    2010-10-13

    The Protein Circular Dichroism Data Bank (PCDDB) is a newly released resource for structural biology. It is a web-accessible (http://pcddb.cryst.bbk.ac.uk) data bank for circular dichroism (CD) and synchrotron radiation circular dichroism (SRCD) spectra and their associated experimental and secondary metadata, with links to protein sequence and structure data banks. It is designed to provide a public repository for CD spectroscopic data on macromolecules, to parallel the Protein Data Bank (PDB) for crystallographic, electron microscopic, and nuclear magnetic resonance spectroscopic data. Similarly to the PDB, it includes validation checking procedures to ensure good practice and the integrity of the deposited data. This paper reports on the first public release of the PCDDB, which provides access to spectral data that comprise standard reference datasets. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. SPECTROSCOPIC SIGNATURES RELATED TO A SUNQUAKE

    International Nuclear Information System (INIS)

    Matthews, S. A.; Harra, L. K.; Green, L. M.; Zharkov, S.

    2015-01-01

    The presence of flare-related acoustic emission (sunquakes (SQs)) in some flares, and only in specific locations within the flaring environment, represents a severe challenge to our current understanding of flare energy transport processes. In an attempt to contribute to understanding the origins of SQs we present a comparison of new spectral observations from Hinode’s EUV imaging Spectrometer (EIS) and the Interface Region Imaging Spectrograph (IRIS) of the chromosphere, transition region, and corona above an SQ, and compare them to the spectra observed in a part of the flaring region with no acoustic signature. Evidence for the SQ is determined using both time–distance and acoustic holography methods, and we find that unlike many previous SQ detections, the signal is rather dispersed, but that the time–distance and 6 and 7 mHz sources converge at the same spatial location. We also see some evidence for different evolution at different frequencies, with an earlier peak at 7 mHz than at 6 mHz. Using EIS and IRIS spectroscopic measurements we find that in this location, at the time of the 7 mHz peak the spectral emission is significantly more intense, shows larger velocity shifts and substantially broader profiles than in the location with no SQ, and there is a good correlation between blueshifted, hot coronal, hard X-ray (HXR), and redshifted chromospheric emission, consistent with the idea of a strong downward motion driven by rapid heating by nonthermal electrons and the formation of chromospheric shocks. Exploiting the diagnostic potential of the Mg ii triplet lines, we also find evidence for a single large temperature increase deep in the atmosphere, which is consistent with this scenario. The time of the 6 mHz and time–distance peak signal coincides with a secondary peak in the energy release process, but in this case we find no evidence of HXR emission in the quake location, instead finding very broad spectral lines, strongly shifted to the red

  19. Spectroscopic analysis of chromium bioremediation products

    Science.gov (United States)

    Varadharajan, C.; Nico, P. S.; Yang, L.; Marcus, M. A.; Steefel, C.; Larsen, J. T.; Beller, H. R.; Brodie, E. L.

    2010-12-01

    Remediation of chromium contamination frequently involves reducing the toxic and soluble hexavalent form, Cr(VI), to the relatively harmless and mostly immobile trivalent state, Cr(III). The objective of this study is to identify the biogeochemical reactions that control in situ chromium reduction in the presence of different dominant electron acceptors, i.e., NO3-, Fe(III), and SO42-. It was hypothesized that indirect, abiotic reduction of Cr(VI) by reduced metabolic products [Fe(II) and sulfides] would dominate over direct enzymatic reduction by denitrifying, iron-reducing, or sulfate-reducing bacteria. It is further hypothesized that the enzymatic reduction of Cr(VI) would produce relatively pure chromium hydroxide precipitates, whereas indirect reduction would result in mixed Cr-Fe hydroxide solid phases. Flow-through columns containing homogenized sediments from the 100H site at Hanford, WA were subjected to nitrate-, sulfate- or iron-reducing conditions in the presence of 5 µM Cr(VI) and 5 mM lactate. Cr(VI) was depleted in the effluent solutions from the nitrate- and sulfate-reducing columns; however only a small amount of Cr(VI) was removed under iron-reducing conditions. Preliminary analysis of micro X-ray absorption spectra indicate that the untreated and iron-reducing column sediments contained pre-existing Cr in the form of primary minerals, e.g. chromite and/or Cr-bearing micas. However, there was an increase in the relative abundance of mixed-phase Cr-Fe hydroxides, i.e., Cr1-xFex(OH)3 in the nitrate- and sulfate-treated columns. A possible explanation for the observations is that the production of Fe(II) was enhanced under the nitrate- and sulfate- reducing conditions, and was most likely sulfide-driven in the latter case. The Fe(II) was subsequently available for reduction of Cr(VI) resulting in the mixed-phase precipitates. The results from the spectroscopic analysis support the hypothesis that Fe(II)-mediated Cr reduction prevails over direct

  20. Moessbauer spectroscopic characterization of ferrite ceramics

    International Nuclear Information System (INIS)

    Music, S.; Ristic, M.

    1999-01-01

    The principle of Moessbauer effect and the nature of hyperfine interactions were presented. The discovery of the Moessbauer effect was the basis of a new spectroscopic technique, called Moessbauer spectroscopy, which has already made important contribution to research in physics, chemistry, metallurgy, mineralogy and biochemistry. In the present work the selected ferrites such as spinel ferrite, NiFe 2 O 4 , and some rare earth orthoferrites and garnets were investigated using Moessbauer spectroscopy. X-ray powder diffraction and Fourier transform infrared spectroscopy were used as complementary techniques. The formation of NiFe 2 O 4 was monitored during the thermal decomposition of mixed salt (Ni(NO 3 ) 2 +2Fe(NO 3 ) 3 )nH 2 O. The ferritization of Ni 2+ ions was observed at 500 deg. C and after heating at 1300 deg. C the stoichiometric NiFe 2 O 4 was produced. The Moessbauer parameters obtained for NiFe 2 O 4 , d Fe = 0.36 mm s -1 and HMF = 528 kOe, can be ascribed to Fe 3+ ions in the octahedral sublattice, while parameters d Fe = 0.28 mm s -1 and HMF = 494 kOe can be ascribed to Fe 3+ ions in the tetrahedral lattice. The effect of ball-milling of NiFe 2 O 4 was monitored. The formation of oxide phases and their properties in the systems Nd 2 O 3 -Fe 2 O 3 , Sm 2 O 3 -Fe 2 O 3 , Gd 2 O 3 -Fe 2 O 3 , Eu 2 O 3 -Fe 2 O 3 and Er 2 O 3 -Fe 2 O 3 were also investigated. Quantitative distributions of oxide phases, a-Fe 2 O 3 , R 2 O 3 , R 3 Fe 5 O 12 and RFeO 3 , R = Gd or Eu, were determined for the systems xGd 2 O 3 +(1-x)Fe 2 O 3 and xEu 2 O 3 +(1-x)Fe 2 O 3 . The samples, prepared by chemical coprecipitation in the system xEu 2 O 3 +(1-x)Fe 2 O 3 , 0≤x≤1, were completely amorphous as observed by XRD, even at the relatively high temperature of the sample preparation (600 deg. C). Similar behavior was observed during the formation of Er 3 Fe 5 O 12 . Moessbauer spectroscopy indicated that this 'amorphous' phase is actually composed of very small and/or poor

  1. Spectroscopic studies on colloid-borne uranium

    International Nuclear Information System (INIS)

    Ulrich, K.U.; Weiss, S.; Foerstendorf, H.; Brendler, V.; Zaenker, H.; Rossberg, A.; Scheinost, A.C.

    2005-01-01

    Full text of publication follows: Information on molecular speciation provides a basis for the reliable assessment of actinide migration in the environment. We use several methods for the separation of colloids from liquids (e.g. ultracentrifugation, ultrafiltration) in combination with spectroscopic techniques (EXAFS, ATR-FTIR, Moessbauer) and modeling of surface complexation reactions. This enables us to investigate the speciation of colloid-borne uranium in waters occurring in or escaping from abandoned uranium mines during the remediation process. Mine flooding was simulated on a 100 L scale by mixing acid mine water of elevated U concentration with oxic, near-neutral groundwater until pH ∼ 5.5 was reached. The freshly formed colloids adsorbed 95% of the total uranium and consisted mainly of 2-line ferri-hydrite (Fh) besides traces of aluminum, sulfur, silica, and carbon compounds. EXAFS analysis at the U-LIII absorption edge suggested a bidentate surface complex of UO 2 2+ on FeO 6 octahedra, but two minor backscattering contributions in close vicinity to the absorber remained unexplained. Since only Al could be excluded as backscattering atom, we studied U sorption on Fh at pH 5.5 in presence and in absence of sulfate, silicate, and atmospheric CO 2 to clarify the bond structure. EXAFS showed the unknown backscattering contributions in all the sorption samples regardless of the presence or absence of the tested components. Contrary to structural models proposed in the literature, bi-dentately complexed carbonate ligands do not explain our experimental EXAFS data. But ATR-IR spectra showed that U-carbonato complexes must be involved in the sorption of uranyl on Fh. These results are not contradictory if the carbonate ligands were bound mono-dentately. Nevertheless, carbon cannot act as backscattering atom in carbonate-free samples prepared in N 2 atmosphere. We propose a new structural model including exclusively Fe, H, and O atoms in which the bi

  2. SARA (Spectroscopic Ambient Radiation Detection) Spectroscopic Monitoring Systems for Online Environmental Radiation Monitoring Edition 2008

    International Nuclear Information System (INIS)

    Holzheimer, C.; Hartmann, S.

    2009-01-01

    In the wake of a nuclear incident, it is essential that you can react promptly and provide a completely reliable assessment of the radiological situation. First and foremost, it is vital that your radiation early warning system can automatically detect any man-made isotopes in the environment and identify any changes in the composition of the ambient radiation. Before appropriate countermeasures can be implemented, it is crucial that authorities have accurate information about the type of contamination and its dispersion. TechniData's spectroscopic online monitoring system will improve your existing monitoring systems, provide important information about the composition of ambient radiation during an incident, and therefore help you to make the right decisions

  3. Whole-brain analysis of amyotrophic lateral sclerosis by using echo-planar spectroscopic imaging.

    Science.gov (United States)

    Verma, Gaurav; Woo, John H; Chawla, Sanjeev; Wang, Sumei; Sheriff, Sulaiman; Elman, Lauren B; McCluskey, Leo F; Grossman, Murray; Melhem, Elias R; Maudsley, Andrew A; Poptani, Harish

    2013-06-01

    To detect regional metabolic differences in amyotrophic lateral sclerosis (ALS) with whole-brain echo-planar spectroscopic imaging. Sixteen patients with ALS (nine men, seven women; mean age, 56.6 years), five persons suspected of having ALS (four men, one woman; mean age, 62.6 years), and 10 healthy control subjects (five men, five women; mean age, 56.1 years) underwent echo-planar spectroscopic imaging after providing informed consent. The study was approved by the institutional review board and complied with HIPAA. Data were analyzed with the Metabolic Imaging and Data Analysis System software, and processed metabolite maps were coregistered and normalized to a standard brain template. Metabolite maps of creatine (Cr), choline (Cho), and N-acetylaspartate (NAA) were segmented into 81 regions with Automated Anatomical Labeling software to measure metabolic changes throughout the brains of patients with ALS. Statistical analysis involved an unpaired, uncorrected, two-sided Student t test. The NAA/Cho ratio across six regions was significantly lower by a mean of 23% (P ≤ .01) in patients with ALS than in control subjects. These regions included the caudate, lingual gyrus, supramarginal gyrus, and right and left superior and right inferior occipital lobes. The NAA/Cr ratio was significantly lower (P ≤ .01) in eight regions in the patient group, by a mean of 16%. These included the caudate, cuneus, frontal inferior operculum, Heschl gyrus, precentral gyrus, rolandic operculum, and superior and inferior occipital lobes. The Cho/Cr ratio did not significantly differ in any region between patient and control groups. Whole-brain echo-planar spectroscopic imaging permits detection of regional metabolic abnormalities in ALS, including not only the motor cortex but also several other regions implicated in ALS pathophysiologic findings.

  4. Fourier Transform Infrared Spectroscopic Determination of Shale ...

    African Journals Online (AJOL)

    A Classical Least Square (CLS) model was developed from the attenuated spectra of mixtures of five mineral standards chosen to represent the most frequently encountered minerals in shale-type reservoir rocks namely: quartz, illite/smectite (30:70), kaolinite, calcite and dolomite. The CLS model developed was able to ...

  5. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    International Nuclear Information System (INIS)

    Stratton, B.C.; Bitter, M.; Hill, K.W.; Hillis, D.L.; Hogan, J.T.

    2007-01-01

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  6. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, B. C.; Biter, M.; Hill, K. W.; Hillis, D. L.; Hogan, J. T.

    2007-07-18

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  7. SPECTROSCOPIC ORBITS FOR 15 LATE-TYPE STARS

    Energy Technology Data Exchange (ETDEWEB)

    Willmarth, Daryl W.; Abt, Helmut A. [Kitt Peak National Observatory, Box 26732, Tucson, AZ 85726-6732 (United States); Fekel, Francis C. [Center of Excellence in Information Systems, Tennessee State University, 3500 John A. Merritt Boulevard, Box 9501, Nashville, TN 37209 (United States); Pourbaix, Dimitri, E-mail: dwillmarth@noao.edu, E-mail: habt@noao.edu, E-mail: fekel@evans.tsuniv.edu, E-mail: pourbaix@astro.ulb.ac.be [FNRS Institut d’Astronomie et d’Astrophysique, Université Libre de Bruxelles, CP 226, B-1050 Bruxelles (Belgium)

    2016-08-01

    Spectroscopic orbital elements are determined for 15 stars with periods from 8 to 6528 days with six orbits computed for the first time. Improved astrometric orbits are computed for two stars and one new orbit is derived. Visual orbits were previously determined for four stars, four stars are members of multiple systems, and five stars have Hipparcos “G” designations or have been resolved by speckle interferometry. For the nine binaries with previous spectroscopic orbits, we determine improved or comparable elements. For HD 28271 and HD 200790, our spectroscopic results support the conclusions of previous authors that the large values of their mass functions and lack of detectable secondary spectrum argue for the secondary in each case being a pair of low-mass dwarfs. The orbits given here may be useful in combination with future interferometric and Gaia satellite observations.

  8. Beam divergence correction method for neutron resonance spin echo spectroscope

    International Nuclear Information System (INIS)

    Maruyama, Ryuji; Tasaki, Seiji; Hino, Masahiro; Kitaguchi, Masaaki; Kawabata, Yuji; Ebisawa, Toru

    2005-01-01

    A beam divergence correction method for Neutron resonance spin echo (NRSE) spectroscope was proposed and the effectiveness is evaluated by simulation. When a beam divergence correction coil was introduced into NRSE spectroscope and the optimum magnetic field was given, the visibility of spin echo signal was recovered by controlling scattering of phase difference generated by beam divergence. The effectiveness of the correction method was proved by the above result. Principle of NRSE spectroscopy, decrease of spin polarization rate by beam divergence and its correction method, structure of divergence angle correction coil and the magnetic field calculation and result of simulation are described. (S.Y.)

  9. Spectroscopic techniques to study the immune response in human saliva

    Science.gov (United States)

    Nepomnyashchaya, E.; Savchenko, E.; Velichko, E.; Bogomaz, T.; Aksenov, E.

    2018-01-01

    Studies of the immune response dynamics by means of spectroscopic techniques, i.e., laser correlation spectroscopy and fluorescence spectroscopy, are described. The laser correlation spectroscopy is aimed at measuring sizes of particles in biological fluids. The fluorescence spectroscopy allows studying of the conformational and other structural changings in immune complex. We have developed a new scheme of a laser correlation spectrometer and an original signal processing algorithm. We have suggested a new fluorescence detection scheme based on a prism and an integrating pin diode. The developed system based on the spectroscopic techniques allows studies of complex process in human saliva and opens some prospects for an individual treatment of immune diseases.

  10. Spectroscopic study of low-lying 16N levels

    International Nuclear Information System (INIS)

    Bardayan, Daniel W.; O'Malley, Patrick; Blackmon, Jeff C.; Chae, K.Y.; Chipps, K.; Cizewski, J.A.; Hatarik, Robert; Jones, K.L.; Kozub, R. L.; Matei, Catalin; Moazen, Brian; Nesaraja, Caroline D.; Pain, Steven D.; Paulauskas, Stanley; Peters, W.A.; Pittman, S.T.; Schmitt, Kyle; Shriner, J.F. Jr.; Smith, Michael Scott

    2008-01-01

    The magnitude of the 15N(n,gamma)16N reaction rate in asymptotic giant branch stars depends directly on the neutron spectroscopic factors of low-lying 16N levels. A new study of the 15N(d,p)16N reaction is reported populating the ground and first three excited states in 16N. The measured spectroscopic factors are near unity as expected from shell model calculations, resolving a long-standing discrepancy with earlier measurements that had never been confirmed or understood. Updated 15N(n,gamma)16N reaction rates are presented

  11. Probing superconductors. Spectroscopic-imaging scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Hanaguri, Tetsuo

    2011-01-01

    Discovery of high-temperature superconductivity in a cuprate triggered developments of various spectroscopic tools which have been utilized to elucidate electronic states of this mysterious compound. Particularly, angle-resolved photoemission spectroscopy and scanning-tunneling microscopy/spectroscopy are improved considerably. It is now possible to map the superconducting gap in both momentum and real spaces using these two techniques. Here we review spectroscopic-imaging scanning tunneling microscopy which is able to explore momentum-space phase structure of the superconducting gap, as well as real-space structure. Applications of this technique to a cuprate and an iron-based superconductor are discussed. (author)

  12. Evaluation of multivariate calibration models transferred between spectroscopic instruments

    DEFF Research Database (Denmark)

    Eskildsen, Carl Emil Aae; Hansen, Per W.; Skov, Thomas

    2016-01-01

    In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions for the ......In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions...

  13. Spectroscopical determination of impurities in nuclear graphite

    International Nuclear Information System (INIS)

    Lordello, A.R.; Tognini, R.P.

    1975-01-01

    A spectrochemical method for the direct determination of B, Cd, Si, Hg, Fe, Mg, Mn, Cr, Ni, Al, Mo, Ti, Sr, Na, Zn, and As in nuclear grade graphite is described. A 9:1 ratio of graphite to copper difluoride is used in the preparation of samples and standards. The excitation is carried out in a d-c at 10 amperes. The copper fluoride used as spectrographic buffer serves to increase the volatilization rate of the impurities and to diminish the differences in the nature of the analytical and calibration samples. The relative standard deviations for the determination of the 16 trace elements, except Sr, Fe, Cd, Al and Si, are in the range of 8 - 20% in their appropriate calibration levels. For the latter five elements they are approximately 20-40%

  14. Infrared laser spectroscopic trace gas sensing

    Science.gov (United States)

    Sigrist, Markus

    2016-04-01

    Chemical sensing and analyses of gas samples by laser spectroscopic methods are attractive owing to several advantages such as high sensitivity and specificity, large dynamic range, multi-component capability, and lack of pretreatment or preconcentration procedures. The preferred wavelength range comprises the fundamental molecular absorption range in the mid-infared between 3 and 15 μm, whereas the near-infrared range covers the (10-100 times weaker) higher harmonics and combination bands. The availability of near-infrared and, particularly, of broadly tunable mid-infrared sources like external cavity quantum cascade lasers (EC-QCLs), interband cascade lasers (ICLs), difference frequency generation (DFG), optical parametric oscillators (OPOs), recent developments of diode-pumped lead salt semiconductor lasers, of supercontinuum sources or of frequency combs have eased the implementation of laser-based sensing devices. Sensitive techniques for molecular absorption measurements include multipass absorption, various configurations of cavity-enhanced techniques such as cavity ringdown (CRD), or of photoacoustic spectroscopy (PAS) including quartz-enhanced (QEPAS) or cantilever-enhanced (CEPAS) techniques. The application requirements finally determine the optimum selection of laser source and detection scheme. In this tutorial talk I shall discuss the basic principles, present various experimental setups and illustrate the performance of selected systems for chemical sensing of selected key atmospheric species. Applications include an early example of continuous vehicle emission measurements with a mobile CO2-laser PAS system [1]. The fast analysis of C1-C4 alkanes at sub-ppm concentrations in gas mixtures is of great interest for the petrochemical industry and was recently achieved with a new type of mid-infrared diode-pumped piezoelectrically tuned lead salt vertical external cavity surface emitting laser (VECSEL) [2]. Another example concerns measurements on short

  15. Fourier-transform far-infrared spectroscopic ellipsometry for standoff material identification

    Energy Technology Data Exchange (ETDEWEB)

    Ortolani, Michele, E-mail: michele.ortolani@ifn.cnr.i [Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Via Cineto Romano 42, I-00156 Rome (Italy); Schade, Ulrich [Helmholtz Zentrum Berlin fuer Materialen und Energie, Albert-Einstein-Strasse 15, D-12489 Berlin (Germany)

    2010-11-11

    The ellipsometry is an efficient method to determine the optical properties of matter. It has been largely employed with grating spectrometers in the visible, UV and near-infrared ranges for the characterization of thin films, surfaces and interfaces. In the mid- and far-infrared, where most substance-specific absorption lines are present, spectroscopic ellipsometry with Fourier-transform spectrometers is still not extended as a routine method. In particular, the lack of powerful sources in the far-infrared/terahertz range has prevented standoff application of this method. We will show that it is possible to measure the complex dielectric constant of a solid in the far-infrared and terahertz range by a reflection experiment with polarized light and ellipsometric analysis with a suitable calibration procedure. Extraction of terahertz synchrotron radiation from storage rings provides a suitable source for research-grade experiments. The optical constants determined by ellipsometry compare well with those obtained by Kramers-Kronig procedures, a method which, however, requires broader frequency range and absolute reflectance standard. We will present the case of remote spectroscopic identification of explosive materials, which is relevant for forthcoming security applications.

  16. Spectroscopic analysis applied to temperature measurement in plasmas

    International Nuclear Information System (INIS)

    Fieffe-Prevost, P.

    1978-01-01

    The plasma temperature is defined only if the plasma is in a state near thermodynamic equilibrium. This plasma state is analysed in detail and spectroscopic methods for measuring the temperature are discussed. As an application the hydrogen arc of the National Institute of Metrology of the Conservatoire National des Arts et Metiers (Paris) is briefly described [fr

  17. Smoothing noisy spectroscopic data with many-knot spline method

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, M.H. [Space Exploration Laboratory, Macau University of Science and Technology, Taipa, Macau (China)], E-mail: peter_zu@163.com; Liu, L.G.; Qi, D.X.; You, Z.; Xu, A.A. [Space Exploration Laboratory, Macau University of Science and Technology, Taipa, Macau (China)

    2008-05-15

    In this paper, we present the development of a many-knot spline method derived to remove the statistical noise in the spectroscopic data. This method is an expansion of the B-spline method. Compared to the B-spline method, the many-knot spline method is significantly faster.

  18. Spectroscopic and chemical reactivity analysis of D-Myo-Inositol ...

    Indian Academy of Sciences (India)

    2017-06-20

    Jun 20, 2017 ... ... Pramana – Journal of Physics; Volume 89; Issue 1. Spectroscopic and chemical reactivity analysis of D-Myo-Inositol using quantum chemical approach and its experimental verification. DEVENDRA P MISHRA ANCHAL SRIVASTAVA R K SHUKLA. Special Issue Volume 89 Issue 1 July 2017 Article ID 12 ...

  19. Moessbauer spectroscopic study of South Italic Greek-type pottery

    International Nuclear Information System (INIS)

    Moessbauer spectroscopic (M.S.) study of 19 South Italic Greek-type ceramics was carried out. Two groups can be distinguished, on the grounds of Fe 3+ -sites content. However, the results of archeological and neutron activation analysis run contrary to this classification. (author)

  20. The IACOB spectroscopic database of Northern Galactic OB stars

    Science.gov (United States)

    Simón-Díaz, S.; Castro, N.; Garcia, M.; Herrero, A.; Markova, N.

    2011-01-01

    We present the IACOB spectroscopic database, an homogeneous set of high quality, high resolution spectra of Galactic O- and B-type stars obtained with the FIES spectrograph attached to the Nordic Optical Telescope. We also present some results from ongoing projects using the IACOB database.

  1. Dual-probe spectroscopic fingerprints of defects in graphene

    DEFF Research Database (Denmark)

    Settnes, Mikkel; Power, Stephen; Petersen, Dirch Hjorth

    2014-01-01

    (e.g., an extended graphene sheet). Applying this method, we study the transport anisotropies in pristine graphene sheets, and analyze the spectroscopic fingerprints arising from quantum interference around single-site defects, such as vacancies and adatoms. Furthermore, we demonstrate that the dual...

  2. Fourier transform infrared spectroscopic estimation of crystallinity in ...

    Indian Academy of Sciences (India)

    Wintec

    Fourier transform infrared spectroscopic estimation of crystallinity in SiO2 based rocks. BHASKAR J SAIKIA. †. , G PARTHASARATHY* and N C SARMAH. †. National Geophysical Research Institute, Council of Scientific and Industrial Research, Hyderabad 500 007, India. †. Department of Physics, Dibrugarh University, ...

  3. Comparative study of spectroscopic properties of the low-lying ...

    Indian Academy of Sciences (India)

    985–994. c Indian Academy of Sciences. Comparative study of spectroscopic properties of the low-lying electronic states of 2,4-pentadien-1-iminium cation and its N-substituted analogues. ANJAN CHATTOPADHYAY. Department of Chemistry, Birla Institute of Technology and Science (BITS), Pilani –KK Birla Goa Campus,.

  4. Spectroscopic characterization of manganese-doped alkaline earth

    Indian Academy of Sciences (India)

    The intensity and frequency variations for the characteristic phosphate group vibrations have been correlated with the changes of the structural units present in these glasses. Depolymerization of the phosphate chains in all the glasses is observed with replacement of alkaline earth content by spectroscopic studies.

  5. Structural, spectroscopic and electrochemical study of V 5 ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 37; Issue 4. Structural, spectroscopic and electrochemical study of V5+ substituted LiTi2(PO4)3 solid electrolyte for lithium-ion batteries. A Venkateswara Rao V Veeraiah A V Prasada Rao B Kishore Babu B Swarna Latha K Rama Rao. Volume 37 Issue 4 June 2014 pp ...

  6. Spectroscopic characterization of manganese-doped alkaline earth ...

    Indian Academy of Sciences (India)

    Alkaline earth lead zinc phosphate glasses doped with Mn(II) are characterized by spectroscopic techniques like X-ray diffraction (XRD), UV–visible, differential scanning calorimetry (DSC), electron paramagnetic resonance (EPR), Fourier transform infrared (FTIR) and Raman. Optical absorption spectrum exhibits four ...

  7. Study of the spectroscopic characteristics of methyl (ligand ...

    Indian Academy of Sciences (India)

    TECS

    Abstract. Spectroscopic characterization (IR, NMR and electronic spectra) of methyl (ligand) coba- loxime was done, where ligand = pyrazole, dimethyl pyrazole, alanine and alanine methyl ester. The fre- quency changes in the IR spectra and shifts in the NMR were explained on the basis of basicity of the ligand, steric ...

  8. Synthesis and Spectroscopic Analysis of Schiff Bases of Imesatin ...

    African Journals Online (AJOL)

    ADOWIE PERE

    Keywords: Schiff bases, isatin, imesatin, spectroscopic analysis, biological activity. Isatin (1H-indole-2, 3-Dione) was first synthesized by. Erdman, 1840 and established by Laurent, 1841 as a product from the oxidation of indigo by nitric and chromic acids. The synthetic versatility of Isatin has led to the wide applications of ...

  9. 129I Moessbauer spectroscopic study of metallocene-iodine adducts

    International Nuclear Information System (INIS)

    Nakashima, Satoru; Sakai, Hiroshi; Watanabe, Masanobu; Maeda, Yutaka

    1994-01-01

    A 129 I Moessbauer spectroscopic study of iodine adducts of ferrocenophane, biruthenocene, and osmocene is reported. The spectra show the existence of iodine bonded to the central metals of metallocenes in addition to triiodide anions. The valence state of iron in the ferrocenophane-iodine adduct is the same as those of ruthenium and osmium in their adducts. (orig.)

  10. 4MOST: 4-metre Multi-Object Spectroscopic Telescope

    NARCIS (Netherlands)

    de Jong, Roelof S.; Barden, Sam; Bellido-Tirado, Olga; Brynnel, Joar; Chiappini, Cristina; Depagne, Éric; Haynes, Roger; Johl, Diana; Phillips, Daniel P.; Schnurr, Olivier; Schwope, Axel D.; Walcher, Jakob; Bauer, Svend M.; Cescutti, Gabriele; Cioni, Maria-Rosa L.; Dionies, Frank; Enke, Harry; Haynes, Dionne M.; Kelz, Andreas; Kitaura, Francisco S.; Lamer, Georg; Minchev, Ivan; Müller, Volker; Nuza, Sebastián. E.; Olaya, Jean-Christophe; Piffl, Tilmann; Popow, Emil; Saviauk, Allar; Steinmetz, Matthias; Ural, Uǧur; Valentini, Monica; Winkler, Roland; Wisotzki, Lutz; Ansorge, Wolfgang R.; Banerji, Manda; Gonzalez Solares, Eduardo; Irwin, Mike; Kennicutt, Robert C.; King, David M. P.; McMahon, Richard; Koposov, Sergey; Parry, Ian R.; Sun, Xiaowei; Walton, Nicholas A.; Finger, Gert; Iwert, Olaf; Krumpe, Mirko; Lizon, Jean-Louis; Mainieri, Vincenzo; Amans, Jean-Philippe; Bonifacio, Piercarlo; Cohen, Matthieu; François, Patrick; Jagourel, Pascal; Mignot, Shan B.; Royer, Frédéric; Sartoretti, Paola; Bender, Ralf; Hess, Hans-Joachim; Lang-Bardl, Florian; Muschielok, Bernard; Schlichter, Jörg; Böhringer, Hans; Boller, Thomas; Bongiorno, Angela; Brusa, Marcella; Dwelly, Tom; Merloni, Andrea; Nandra, Kirpal; Salvato, Mara; Pragt, Johannes H.; Navarro, Ramón; Gerlofsma, Gerrit; Roelfsema, Ronald; Dalton, Gavin B.; Middleton, Kevin F.; Tosh, Ian A.; Boeche, Corrado; Caffau, Elisabetta; Christlieb, Norbert; Grebel, Eva K.; Hansen, Camilla J.; Koch, Andreas; Ludwig, Hans-G.; Mandel, Holger; Quirrenbach, Andreas; Sbordone, Luca; Seifert, Walter; Thimm, Guido; Helmi, Amina; trager, Scott C.; Bensby, Thomas; Feltzing, Sofia; Ruchti, Gregory; Edvardsson, Bengt; Korn, Andreas; Lind, Karin; Boland, Wilfried; Colless, Matthew; Frost, Gabriella; Gilbert, James; Gillingham, Peter; Lawrence, Jon; Legg, Neville; Saunders, Will; Sheinis, Andrew; Driver, Simon; Robotham, Aaron; Bacon, Roland; Caillier, Patrick; Kosmalski, Johan; Laurent, Florence; Richard, Johan

    4MOST is a wide-field, high-multiplex spectroscopic survey facility under development for the VISTA telescope of the European Southern Observatory (ESO). Its main science drivers are in the fields of galactic archeology, high-energy physics, galaxy evolution and cosmology. 4MOST will in particular

  11. Spectroscopic and antimicrobial studies of polystyrene films under ...

    Indian Academy of Sciences (India)

    Spectroscopic and antimicrobial studies of polystyrene films under air plasma and He-Ne laser treatment ... The parameters such as (1) surface area by contact angle measurements, (2) quality of material before and after treatment by SEM and FTIR spectra and (3) material characterization by UV-vis spectra were studied.

  12. Spectroscopic factors for two-proton radioactive nuclei

    Indian Academy of Sciences (India)

    Abstract. Spectroscopic factors for two-proton emitting nuclei are discussed in the framework of the BCS (Bardeen–Cooper–Schriefer) model. Calculations carried out for the two-proton unstable 45Fe, 48Ni and 54Zn nuclei are presented.

  13. Spectroscopic and Photometric Observations of SN 2004dj

    Czech Academy of Sciences Publication Activity Database

    Korčáková, Daniela; Mikulášek, Z.; Kawka, Adela; Kubát, Jiří; Hornoch, K.; Kotková, Lenka; Kušnirák, Peter; Hadrava, Petr; Wolf, M.; Šlechta, Miroslav; Škoda, Petr; Dovčiak, Michal; Libich, Jan

    -, č. 5605 (2005), s. 1 ISSN 0374-0676 R&D Projects: GA ČR GA205/02/0445; GA ČR GA205/04/1267; GA ČR GP205/04/P224 Institutional research plan: CEZ:AV0Z1003909 Keywords : Spectroscopic observations Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  14. AC impedance and dielectric spectroscopic studies of Mg ion ...

    Indian Academy of Sciences (India)

    Mater. Sci., Vol. 34, No. 5, August 2011, pp. 1063–1067. c Indian Academy of Sciences. AC impedance and dielectric spectroscopic studies of Mg. 2+ ion conducting PVA–PEG blended polymer electrolytes. ANJI REDDY POLU. ∗ and RANVEER KUMAR. Department of Physics, Dr H S Gour University, Sagar 470 003, India.

  15. Spectroscopic Analysis of the Eclipsing Binary∝ CrB

    Indian Academy of Sciences (India)

    The eclipsing binary ∝ CrB, is a well-known double-lined spectroscopic binary. The system is considered unique among main-sequence systems with respect to its small mass ratio and large magnitude difference between the components. Our aim in the present paper is to compute the orbital parameters and to model the ...

  16. X-ray fluorescence spectroscopic determination of heavy metals and ...

    African Journals Online (AJOL)

    X-ray fluorescence spectroscopic determination of heavy metals and trace elements in aerial parts of Origanum sipyleum L from Turkey. ... Among other constituents, arsenic, lead and uranium levels were < 1, 2.1 and < 3 ppm, respectively, in the powdered material while in the aqueous extract, the levels were < 1, < 2 and ...

  17. FT-IR, NMR SPECTROSCOPIC and QUANTUM MECHANICAL ...

    African Journals Online (AJOL)

    FT-IR, NMR SPECTROSCOPIC and QUANTUM MECHANICAL. INVESTIGATIONS OF TWO FERROCENE DERIVATIVES. Özgür Alver1* and Cemal Parlak2. 1Department of Physics, Science Faculty, Anadolu University, Eskişehir, 26470, Turkey. 2Department of Physics, Science Faculty, Ege University, İzmir, 35100, ...

  18. Spectroscopic orbit for HDE 245770 A0535+26

    International Nuclear Information System (INIS)

    Hutchings, J.B.

    1984-01-01

    Optical spectroscopic data are examined using the X-ray intensity period of 111 days. Optical and X-ray pulse-timing orbit parameters agree well and indicate an eccentricity of approximately 0.3. Masses of the stars and periastron effects are discussed. 6 references

  19. Spectroscopic probes of vibrationally excited molecules at chemically significant energies

    Energy Technology Data Exchange (ETDEWEB)

    Rizzo, T.R. [Univ. of Rochester, NY (United States)

    1993-12-01

    This project involves the application of multiple-resonance spectroscopic techniques for investigating energy transfer and dissociation dynamics of highly vibrationally excited molecules. Two major goals of this work are: (1) to provide information on potential energy surfaces of combustion related molecules at chemically significant energies, and (2) to test theoretical modes of unimolecular dissociation rates critically via quantum-state resolved measurements.

  20. Arsenate Adsorption On Ruthenium Oxides: A Spectroscopic And Kinetic Investigation

    Science.gov (United States)

    Arsenate adsorption on amorphous (RuO2•1.1H2O) and crystalline (RuO2) ruthenium oxides was evaluated using spectroscopic and kinetic methods to elucidate the adsorption mechanism. Extended X-ray absorption fine structure spectroscopy (EXAFS) was ...

  1. Quantitative comparison of analysis methods for spectroscopic optical coherence tomography

    NARCIS (Netherlands)

    Bosschaart, Nienke; van Leeuwen, Ton G.; Aalders, Maurice C. G.; Faber, Dirk J.

    2013-01-01

    Spectroscopic optical coherence tomography (sOCT) enables the mapping of chromophore concentrations and image contrast enhancement in tissue. Acquisition of depth resolved spectra by sOCT requires analysis methods with optimal spectral/spatial resolution and spectral recovery. In this article, we

  2. Time- and Space-Resolved Spectroscopic Investigation on Pi-Conjugated Nanostructures - 2

    Science.gov (United States)

    2016-01-12

    conformations and the location of fluorescent trapping sites in multichromophoric macrocycles using single- molecule spectroscopic methods provides...multichromophoric macrocycles using single-molecule spectroscopic methods provides not only a new level of understanding, but will also stimulate other...AFRL-AFOSR-JP-TR-2016-0029 Time- and Space-Resolved Spectroscopic Investigation on Pi-Conjugated Nanostructures - 2 Dongho Kim YONSEI UNIVERSITY

  3. Determination of Cephalexin Monohydrate in Pharmaceutical Dosage Form by Stability-Indicating RP-UFLC and UV Spectroscopic Methods.

    Science.gov (United States)

    Panda, Sagar Suman; Ravi Kumar, Bera V V; Dash, Rabisankar; Mohanta, Ganeswar

    2013-01-01

    An ultra-fast liquid chromatographic method and two UV spectroscopic methods were developed for the determination of cephalexin monohydrate in pharmaceutical dosage forms. Isocratic separation was performed on an Enable C18G column (250 mm × 4.6 mm i.d., 5 μm) using methanol:0.01 M TBAHS (50:50, v/v) as the mobile phase at a flow rate of 1.0 ml/min. The PDA detection wavelength was set at 254 nm. The UV spectroscopic method was performed at 261 nm and at 256-266 nm for the AUC method using a phosphate buffer (pH=5.5). The linearity was observed over a concentration range of 1.0-120 μg/ml for UFLC and both of the UV spectroscopic methods (correlation coefficient=0.999). The developed methods were validated according to ICH guidelines. The relative standard deviation values for the intraday and interday precision studies were 99% for all of the three methods. The developed methods were used successfully for the determination of cephalexin in dry syrup formulation.

  4. Spectroscopic characterization of matrix isolated transient species

    Science.gov (United States)

    Lue, Christopher J.

    short lived fluorescence was assigned to UCl 4, and the long-lived fluorescence was assigned to UOCl x. A low resolution map for the electronic levels in UOCl x was created. One of the first LIF studies of actinide containing molecules was performed by Grzybowski and Andrews[1] for UF6. While, the same group later recorded IR spectra for the UFx fragements[2], no fluorescence spectra were recorded. Spectra were recorded here of UF x fragments trapped in solid formed by either passing UF 6 through a microwave discharge or ablating U atoms into an F2 /Ar mixture. At the time of these experiments, the IR spectrometer was not available, and the molecules producing the fluorescence could not be deduced solely from the LIF spectra. A comparison with previous IR spectra[2] gave some indication of possible candidates. In all the experiments that investigated uranium containing matrices with IR spectroscopy, UN2 was observed. A search was undertaken to observe fluorescence from UN2. To insure a good yield of UN 2, 1% N2 was added to the carrier gas. The fluorescence spectra observed in these experiments was very intriguing, but was determined not to be coming from UN2, rather it appears to be coming from U atom clusters. However further experiments are necessary to confirm how many atoms are in the clusters. The final part of this thesis focuses on the electronic spectra of Xe-OH isolated solid Ar. Rare gas radical systems (Rg-X) such as Rg-OH are a good model system for studying weak, long range intermolecular interactions. It is known that when Rg=Xe, the strength of the interaction is much larger. For most Rg-OH complexes, the spectroscopic constants have been determined previously[3]. However, the constants for Xe-OH ares currently undetermined. Gas-phase studies were undertaken to determined these constants.[4] However, these experiments were in conflict with previous LIF spectra recorded in a matrix in which Goodman and Brus[5] observed that the A → X emission band for

  5. A SPECTROSCOPIC AND PHOTOMETRIC SURVEY OF NOVAE IN M31

    International Nuclear Information System (INIS)

    Shafter, A. W.; Darnley, M. J.; Bode, M. F.; Hounsell, R. A.; Hornoch, K.; Filippenko, A. V.; Chornock, R.; Ciardullo, R.; Misselt, K. A.; Matheson, T.

    2011-01-01

    We report the results of a multi-year spectroscopic and photometric survey of novae in M31 that resulted in a total of 53 spectra of 48 individual nova candidates. Two of these, M31N 1995-11e and M31N 2007-11g, were revealed to be long-period Mira variables, not novae. These data double the number of spectra extant for novae in M31 through the end of 2009 and bring to 91 the number of M31 novae with known spectroscopic classifications. We find that 75 novae (82%) are confirmed or likely members of the Fe II spectroscopic class, with the remaining 16 novae (18%) belonging to the He/N (and related) classes. These numbers are consistent with those found for Galactic novae. We find no compelling evidence that spectroscopic class depends sensitively on spatial position or population within M31 (i.e., bulge versus disk), although the distribution for He/N systems appears slightly more extended than that for the Fe II class. We confirm the existence of a correlation between speed class and ejection velocity (based on line width), as in the case of Galactic novae. Follow-up photometry allowed us to determine light-curve parameters for a total of 47 of the 91 novae with known spectroscopic class. We confirm that more luminous novae generally fade the fastest and that He/N novae are typically faster and brighter than their Fe II counterparts. In addition, we find a weak dependence of nova speed class on position in M31, with the spatial distribution of the fastest novae being slightly more extended than that of slower novae.

  6. Role of optical spectroscopic methods in neuro-oncological sciences.

    Science.gov (United States)

    Bahreini, Maryam

    2015-01-01

    In the surgical treatment of malignant tumors, it is crucial to characterize the tumor as precisely as possible. The determination of the exact tumor location as well as the analysis of its properties is very important in order to obtain an accurate diagnosis as early as possible. In neurosurgical applications, the optical, non-invasive and in situ techniques allow for the label-free analysis of tissue, which is helpful in neuropathology. In the past decades, optical spectroscopic methods have been investigated drastically in the management of cancer. In the optical spectroscopic techniques, tissue interrogate with sources of light which are ranged from the ultraviolet to the infrared wavelength in the spectrum. The information accumulation of light can be in a reflection which is named reflectance spectroscopy; or interactions with tissue at different wavelengths which are called fluorescence and Raman spectroscopy. This review paper introduces the optical spectroscopic methods which are used to characterize brain tumors (neuro-oncology). Based on biochemical information obtained from these spectroscopic methods, it is possible to identify tumor from normal brain tissues, to indicate tumor margins, the borders towards normal brain tissue and infiltrating gliomas, to distinguish radiation damage of tissues, to detect particular central nervous system (CNS) structures to identify cell types using particular neurotransmitters, to detect cells or drugs which are optically labeled within therapeutic intermediations and to estimate the viability of tissue and the prediction of apoptosis beginning in vitro and in vivo. The label-free, optical biochemical spectroscopic methods can provide clinically relevant information and need to be further exploited to develop a safe and easy-to-use technology for in situ diagnosis of malignant tumors.

  7. The Dynamics of Standardization

    DEFF Research Database (Denmark)

    Brunsson, Nils; Rasche, Andreas; Seidl, David

    2012-01-01

    This paper suggests that when the phenomenon of standards and standardization is examined from the perspective of organization studies, three aspects stand out: the standardization of organizations, standardization by organizations and standardization as (a form of) organization. Following a comp...

  8. Non-invasive spectroscopic techniques in the diagnosis of non-melanoma skin cancer

    Science.gov (United States)

    Drakaki, E.; Sianoudis, IA; Zois, EN; Makropoulou, M.; Serafetinides, AA; Dessinioti, C.; Stefanaki, E.; Stratigos, AJ; Antoniou, C.; Katsambas, A.; Christofidou, E.

    2017-11-01

    The number of non-melanoma skin cancers is increasing worldwide and has become an important health and economic issue. Early detection and treatment of skin cancer can significantly improve patient outcome. Therefore there is an increase in the demand for proper management and effective non-invasive diagnostic modalities in order to avoid relapses or unnecessary treatments. Although the gold standard of diagnosis for non-melanoma skin cancers is biopsy followed by histopathology evaluation, optical non-invasive diagnostic tools have obtained increased attention. Emerging non-invasive or minimal invasive techniques with possible application in the diagnosis of non-melanoma skin cancers include high-definition optical coherence tomography, fluorescence spectroscopy, oblique incidence diffuse reflectance spectrometry among others spectroscopic techniques. Our findings establish how those spectrometric techniques can be used to more rapidly and easily diagnose skin cancer in an accurate and automated manner in the clinic.

  9. Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?

    Science.gov (United States)

    Ershadi, Saba; Shayanfar, Ali

    2018-03-22

    The limit of detection (LOD) and the limit of quantification (LOQ) are common parameters to assess the sensitivity of analytical methods. In this study, the LOD and LOQ of previously reported terbium sensitized analysis methods were calculated by different methods, and the results were compared with sensitivity parameters [lower limit of quantification (LLOQ)] of U.S. Food and Drug Administration guidelines. The details of the calibration curve and standard deviation of blank samples of three different terbium-sensitized luminescence methods for the quantification of mycophenolic acid, enrofloxacin, and silibinin were used for the calculation of LOD and LOQ. A comparison of LOD and LOQ values calculated by various methods and LLOQ shows a considerable difference. The significant difference of the calculated LOD and LOQ with various methods and LLOQ should be considered in the sensitivity evaluation of spectroscopic methods.

  10. Frequency and mode identification of γ Doradus from photometric and spectroscopic observations*

    Science.gov (United States)

    Brunsden, E.; Pollard, K. R.; Wright, D. J.; De Cat, P.; Cottrell, P. L.

    2018-04-01

    The prototype star for the γ Doradus class of pulsating variables was studied employing photometric and spectroscopic observations to determine the frequencies and modes of pulsation. The four frequencies found are self-consistent between the observation types and almost identical to those found in previous studies (1.3641 d-1, 1.8783 d-1, 1.4742 d-1, and 1.3209 d-1). Three of the frequencies are classified as l, m = (1, 1) pulsations and the other is ambiguous between l, m = (2, 0) and (2, -2) modes. Two frequencies are shown to be stable over 20 yr since their first identification. The agreement in ground-based work makes this star an excellent calibrator between high-precision photometry and spectroscopy with the upcoming TESS observations and a potential standard for continued asteroseismic modelling.

  11. Photoelectron spectroscopic and microspectroscopic probes of ferroelectrics

    Science.gov (United States)

    Tǎnase, Liviu C.; Abramiuc, Laura E.; Teodorescu, Cristian M.

    2017-12-01

    This contribution is a review of recent aspects connected with photoelectron spectroscopy of free ferroelectric surfaces, metals interfaced with these surfaces, graphene-like layers together with some exemplifications concerning molecular adsorption, dissociations and desorptions occurring from ferroelectrics. Standard photoelectron spectroscopy is used nowadays in correlation with other characterization techniques, such as piezoresponse force microscopy, high resolution transmission electron spectroscopy, and ferroelectric hysteresis cycles. In this work we will concentrate mainly on photoelectron spectroscopy and spectro-microscopy characterization of ferroelectric thin films, starting from atomically clean ferroelectric surfaces of lead zirco-titanate, then going towards heterostructures using this material in combination with graphene-like carbon layers or with metals. Concepts involving charge accumulation and depolarization near surface will be revisited by taking into account the newest findings in this area.

  12. Spectroscopic instrumentation fundamentals and guidelines for astronomers

    CERN Document Server

    Eversberg, Thomas

    2015-01-01

    In order to analyze the light of cosmic objects, particularly at extremely great distances, spectroscopy is the workhorse of astronomy. In the era of very large telescopes, long-term investigations are mainly performed with small professional instruments. Today they can be done using self-designed spectrographs and highly efficient CCD cameras, without the need for large financial investments.   This book explains the basic principles of spectroscopy, including the fundamental optical constraints and all mathematical aspects needed to understand the working principles in detail. It covers the complete theoretical and practical design of standard and Echelle spectrographs. Readers are guided through all necessary calculations, enabling them to engage in spectrograph design. The book also examines data acquisition with CCD cameras and fiber optics, as well as the constraints of specific data reduction and possible sources of error. In closing it briefly highlights some main aspects of the research on massive s...

  13. Data standards for the international virtual observatory

    Directory of Open Access Journals (Sweden)

    R J Hanisch

    2006-11-01

    Full Text Available A primary goal of the International Virtual Observatory Alliance, which brings together Virtual Observatory Projects from 16 national and international development projects, is to develop, evaluate, test, and agree upon standards for astronomical data formatting, data discovery, and data delivery. In the three years that the IVOA has been in existence, substantial progress has been made on standards for tabular data, imaging data, spectroscopic data, and large-scale databases and on managing the metadata that describe data collections and data access services. In this paper, I describe how the IVOA operates and give my views as to why such a broadly based international collaboration has been able to make such rapid progress.

  14. Improved spatial localization in magnetic resonance spectroscopic imaging with two-dimensional PSF-Choice encoding.

    Science.gov (United States)

    Zhang, Shelley HuaLei; Maier, Stephan E; Panych, Lawrence P

    2018-03-03

    Magnetic resonance spectroscopic imaging (MRSI), under low-spatial resolution settings, often suffers signal contamination from neighboring voxels due to ringing artifacts. Spatial localization can be improved by constraining the point-spread-function (PSF). Here the effectiveness of the two-dimensional PSF-Choice technique in providing improved spatial localization for MRSI is demonstrated. The PSF-Choice technique constrains the PSF to a desired shape by manipulating the weighting of RF excitation pulse throughout phase-encode steps. Based on a Point REsolved SpectroScopy (PRESS)-type sequence, PSF-Choice encoding was implemented along two dimensions to excite a two-dimensional Gaussian profile, by replacing the usual RF excitation pulse with a train of pulses that is modified at each phase-encoding step. The method was proven mathematically, and demonstrated experimentally in phantoms containing prostate relevant metabolic compounds of choline, creatine and citrate. Using a dedicated prostate-mimicking spectroscopy phantom surrounded by oil, it was found that there is significantly less signal contamination from oil for PSF-Choice encoding compared with standard phase encoding. In particular, with standard phase encoding, there was a significant difference (p = 0.014) between ratios of Choline + Creatine to Citrate for voxels well within the phantom compared to voxels within the phantom but near the boundary with oil. The ratios in boundary voxels were also significantly different (p = 0.035) from reference values obtained using the prostate phantom with no oil present. In contrast, no significant differences were found in comparisons of these ratios when encoding with PSF-Choice. The PSF-Choice scheme applied along two dimensions produces MR spectroscopic images with substantially reduced truncation artifacts and spectral contamination. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Modelling the spectroscopic behaviour of hot molecules

    Science.gov (United States)

    Tennyson, Jonathan

    2010-05-01

    At elevated temperatures the molecules absorb and emit light in a very complicated fashion which is hard to characterise on the basis of laboraroty measurement. Computed line lists of molecule transitions therefore provide a vital input for models of hot atmospheres. I will describe the calculation and use of such line lists including the BT2 water line list [1], which contains some 500 million distinct rotation-vibration transitions. This linelist proved crucial in the detection of water in extrasolar planet HD189733b and has been used extensively in atmospheric modelling. Illustrations will be given at the meeting. A new linelist for the ammonia molecule has just been completed [2] which shows that standard compilations for this molecule need to be improved. Progress on a more extensive linelist for hot ammonia and linelists for other molecules will be discussed at the meeting. [1] R.J. Barber, J. Tennyson, G.J. Harris and R.N. Tolchenov, Mon. Not. R. Astr. Soc., 368, 1087-1094 (2006) [2] S.N. Yurchenko, R.J. Barber, A. Yachmenev, W. Theil, P. Jensen and J. Tennyson, J. Phys. Chem. A, 113, 11845-11855 (2009).

  16. Raman spectroscopic measurements on fluoromethane clathrate hydrates

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T. [Hokkaido Univ., Sapporo (Japan). Graduate School of Engineering, Div. of Applied Physics; Ohmura, R. [Keio Univ., Kohoku-ku, Yokohama (Japan). Dept. of Mechanical Engineering; Hori, A. [Kitami Inst. of Technology, Kitami (Japan). Course of Civil Engineering

    2008-07-01

    The occupation of guest molecules in clathrate-structure cages is of interest to researchers, since this property is involved in the estimation of guest molecule density, the stability of clathrate hydrates, and other features. However, such occupation is known to be non-stoichiometric. It remains difficult to accurately estimate the total amount of natural gases in the hydrates located in the deep ocean or in permafrost. This paper discussed the systematic observations of fluoromethane clathrate hydrates using Raman spectroscopy in conjunction with previously obtained Raman spectra for methane (CH{sub 4}) hydrate. Four types of fluoromethane were utilized as standard guest molecules to investigate cage occupation in the hydrates, as all of them were included in the same crystal structure and shared similar functional groups. The types of fluoromethane that were used included fluoromethane (CH{sub 3}F), difluoromethane (CH{sub 2}F{sub 2}), trifluoromethane (CHF{sub 3}), and tetrafluoromethane (CF{sub 4}). The paper discussed the experimental methods including the temperature and pressure conditions of fluorocarbon hydrate formation. It was concluded that the summary of the Raman peak positions of fluoromethane molecules indicate that the influence of deuterized host molecules on the intramolecular vibration frequencies is less than that suggested by experimental error. The obtained data were confirmed to agree with the empirical model for the Raman peak positions on guest molecules, when the relative position of the guest molecule in a host cage structure is considered. 28 refs., 1 tab., 7 figs.

  17. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  18. Mass spectroscopic analysis of atmospheric particulate matter

    International Nuclear Information System (INIS)

    Wippel, R.

    1997-02-01

    Particulate matter (PM) in the atmosphere vary greatly in origin, in their physical and chemical properties and their effects on climate, atmospheric chemistry and health. Aerosol particles with an aerodynamic diameter less than two μm can enter the respiratory tract of humans when inhaled. Bulk analysis of ambient dust particles was performed using an inductively coupled plasma mass spectrometer (ICP-MS). The size-fractionated collected samples were analyzed after a leaching procedure that simulates the solution reactions occurring in the lungs. A disadvantage of bulk analysis is that it gives no information about the distribution of a certain element within the particles under investigation. A Laser-Microprobe-Mass-Analyzer (LAMMA-500) was used to obtain this information. At sampling sites in Austria and in Zimbabwe, Africa, single particles were sampled using a self-made impactor. One of the final aims in environmental analysis is to successfully apply receptor models that relate the chemical and physical properties of a receptor site to a source. The knowledge of the sources of atmospheric particulate matter is essential for environmental policy makers as well as for epidemiological studies. Artificial neural networks (ANN) have a remarkable ability to handle LAMMA-data. Three ANNs were used as a pattern recognition tool for LAMMA mass spectral data: a back-propagation net, a Kohonen network,and a counter-propagation net. Standard source profiles from the United States Environmental Protection Agency were used as training and test data of the different nets. The elemental patterns of the sum of 100 mass spectra of fine dust particles were presented to the trained nets and satisfactory recognition (> 80 %) was obtained. (author)

  19. Spectroscopic Binaries in the Orion Nebula Cluster and NGC 2264

    Science.gov (United States)

    Kounkel, Marina; Hartmann, Lee; Tobin, John J.; Mateo, Mario; Bailey, John I., III; Spencer, Meghin

    2016-04-01

    We examine the spectroscopic binary population for two massive nearby regions of clustered star formation, the Orion Nebula Cluster (ONC) and NGC 2264, supplementing the data presented by Tobin et al. with more recent observations and more extensive analysis. The inferred multiplicity fraction up to 10 au based on these observations is 5.3 ± 1.2% for NGC 2264 and 5.8 ± 1.1% for the ONC; these values are consistent with the distribution of binaries in the field in the relevant parameter range. Eight of the multiple systems in the sample have enough epochs to perform an initial fit for the orbital parameters. Two of these sources are double-lined spectroscopic binaries; for them, we determine the mass ratio. Our reanalysis of the distribution of stellar radial velocities toward these clusters presents a significantly better agreement between stellar and gas kinematics than was previously thought.

  20. Spectroscopic identification of rare earth elements in phosphate glass

    Science.gov (United States)

    Devangad, Praveen; Tamboli, Maktum; Muhammed Shameem, K. M.; Nayak, Rajesh; Patil, Ajeetkumar; Unnikrishnan, V. K.; Santhosh, C.; Kumar, G. A.

    2018-01-01

    In this work, rare earth-doped phosphate glasses were synthesized and characterized using three different spectroscopic techniques. The absorption spectra of the prepared praseodymium (Pr) and samarium (Sm) doped glasses, recorded by a UV–VIS-NIR spectrophotometer, show the characteristic absorption bands of these elements. To confirm this inference, laser-induced fluorescence spectra of Pr and Sm were obtained at a laser excitation of 442 nm. Their emission bands are reported here. The elemental analysis of these samples was carried out using a laser-induced breakdown spectroscopy (LIBS) system. Characteristic emission lines of Pr and Sm have been identified and reported by the recorded LIBS spectra of glass samples. Results prove that using these three complimentary spectroscopic techniques (absorption, fluorescence and LIBS), we can meaningfully characterize rare earth-doped glass samples.

  1. SPECTROSCOPIC AND INTERFEROMETRIC MEASUREMENTS OF NINE K GIANT STARS

    Energy Technology Data Exchange (ETDEWEB)

    Baines, Ellyn K. [Remote Sensing Division, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375 (United States); Döllinger, Michaela P. [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Guenther, Eike W.; Hatzes, Artie P. [Thüringer Landessternwarte Tautenburg, Sternwarte 5, D-07778 Tautenburg (Germany); Hrudkovu, Marie [Isaac Newton Group of Telescopes, Apartado de Correos 321, E-387 00 Santa Cruz de la Palma, Canary Islands (Spain); Belle, Gerard T. van, E-mail: ellyn.baines@nrl.navy.mil [Lowell Observatory, Flagstaff, AZ 86001 (United States)

    2016-09-01

    We present spectroscopic and interferometric measurements for a sample of nine K giant stars. These targets are of particular interest because they are slated for stellar oscillation observations. Our improved parameters will directly translate into reduced errors in the final masses for these stars when interferometric radii and asteroseismic densities are combined. Here, we determine each star’s limb-darkened angular diameter, physical radius, luminosity, bolometric flux, effective temperature, surface gravity, metallicity, and mass. When we compare our interferometric and spectroscopic results, we find no systematic offsets in the diameters and the values generally agree within the errors. Our interferometric temperatures for seven of the nine stars are hotter than those determined from spectroscopy with an average difference of about 380 K.

  2. Warping methods for spectroscopic and chromatographic signal alignment: a tutorial.

    Science.gov (United States)

    Bloemberg, Tom G; Gerretzen, Jan; Lunshof, Anton; Wehrens, Ron; Buydens, Lutgarde M C

    2013-06-05

    Warping methods are an important class of methods that can correct for misalignments in (a.o.) chemical measurements. Their use in preprocessing of chromatographic, spectroscopic and spectrometric data has grown rapidly over the last decade. This tutorial review aims to give a critical introduction to the most important warping methods, the place of warping in preprocessing and current views on the related matters of reference selection, optimization, and evaluation. Some pitfalls in warping, notably for liquid chromatography-mass spectrometry (LC-MS) data and similar, will be discussed. Examples will be given of the application of a number of freely available warping methods to a nuclear magnetic resonance (NMR) spectroscopic dataset and a chromatographic dataset. As part of the Supporting Information, we provide a number of programming scripts in Matlab and R, allowing the reader to work the extended examples in detail and to reproduce the figures in this paper. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. The Maunakea Spectroscopic ExplorerStatus and System overview

    Science.gov (United States)

    Mignot, S.; Murowinski, R.; Szeto, K.; Blin, A.; Caillier, P.

    2017-12-01

    The Maunakea Spectroscopic Explorer (MSE) project explores the possibility of upgrading the existing CFHT telescope and collaboration to turn it into the most powerful spectroscopic facility available in the years 2020s. Its 10 meter aperture and its 1.5°² hexagonal field of view will allow both large and deep surveys, as complements to current (Gaia, eRosita, LOFAR) and future imaging (Euclid, WFIRST, SKA, LSST) surveys, but also to provide tentative targets to the TMT or the E-ELT. In perfect agreement with INSU's 2015-2020 prospective, besides being well represented in MSE's science team (23/105 members), France is also a major contributor to the Conceptual Design studies with CRAL developing a concept for the low and moderate spectrographs, DT INSU for the prime focus environment and GEPI for systems engineering.

  4. Quantitative Thermodynamic Analyses of Spectroscopic Titration Curves§

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2014-01-01

    Elucidation of ligand - macromolecule interactions requires detailed knowledge of energetics of the formed complexes. Spectroscopic methods are most commonly used in characterizing molecular interactions in solution. The methods do not require large quantities of material and most importantly, do not perturb the studied reactions. However, spectroscopic methods absolutely require the determination of the relationship between the observed signal and the degree of binding in order to obtain meaningful interaction parameters. In other words, the meaningful, thermodynamic interaction parameters can be only determined if the relationship between the observed signal and the degree of binding is determined and not assumed, based on an ad hoc model of the relationship. The approaches discussed here allow an experimenter to quantitatively determine the degree of binding and the free ligand concentration, i.e., they enable to construct thermodynamic binding isotherms in a model-independent fashion. PMID:25284889

  5. The calibration of photographic and spectroscopic films. A densitometric analysis of IIaO film flown aboard the space shuttle transportation system STS3, STS8, and STS7

    Science.gov (United States)

    Hammond, Ernest C., Jr.

    1987-01-01

    The results of these studies have implications for the utilization of the IIaO spectroscopic film on the future shuttle and space lab missions. These responses to standard photonic energy sources will have immediate application for the uneven responses of the film photographing a star field in a terrestrial or extraterrestrial environment with associated digital imaging equipment.

  6. Transient full-field vibration measurement using spectroscopical stereo photogrammetry.

    Science.gov (United States)

    Yue, Kaiduan; Li, Zhongke; Zhang, Ming; Chen, Shan

    2010-12-20

    Contrasted with other vibration measurement methods, a novel spectroscopical photogrammetric approach is proposed. Two colored light filters and a CCD color camera are used to achieve the function of two traditional cameras. Then a new calibration method is presented. It focuses on the vibrating object rather than the camera and has the advantage of more accuracy than traditional camera calibration. The test results have shown an accuracy of 0.02 mm.

  7. Proton decay: spectroscopic probe beyond the proton drip line

    International Nuclear Information System (INIS)

    Seweryniak, D; Davids, C N; Robinson, A; Woods, P J; Blank, B; Carpenter, M P; Davinson, T; Freeman, S J; Hammond, N; Hoteling, N; Janssens, R V F; Khoo, T L; Liu, Z; Mukherjee, G; Shergur, J; Sinha, S; Sonzogni, A A; Walters, W B; Woehr, A

    2005-01-01

    Proton decay has been transformed in recent years from an exotic phenomenon into a powerful spectroscopic tool. The frontiers of experimental and theoretical proton-decay studies will be reviewed. Different aspects of proton decay will be illustrated with recent results on the deformed proton emitter 135 Tb, the odd-odd deformed proton emitter 130 Eu, the complex fine structure in the odd-odd 146 Tm nucleus and on excited states in the transitional proton emitter 145 Tm

  8. Development of Ultra-sensitive Laser Spectroscopic Analysis Technology

    Energy Technology Data Exchange (ETDEWEB)

    Cha, H. K.; Kim, D. H.; Song, K. S. (and others)

    2007-04-15

    Laser spectroscopic analysis technology has three distinct merits in detecting various nuclides found in nuclear fields. High selectivity originated from small bandwidth of tunable lasers makes it possible to distinguish various kinds of isotopes and isomers. High intensity of focused laser beam makes it possible to analyze ultratrace amount. Remote delivery of laser beam improves safety of workers who are exposed in dangerous environment. Also it can be applied to remote sensing of environment pollution.

  9. The IACOB spectroscopic database of galactic OB stars

    Science.gov (United States)

    Simón-Díaz, Sergio; Castro, Norberto; Garcia, Miriam; Herrero, Artemio

    2011-07-01

    We present the IACOB spectroscopic database, the largest homogeneous database of high-resolution, high signal-to-noise ratio spectra of Northern Galactic OB-type stars compiled up to date. The spectra were obtained with the FIES spectrograph attached to the Nordic Optical Telescope. We briefly summarize the main characeristics and present status of the IACOB, first scientific results, and some future plans for its extension and scientific exploitation.

  10. Deformed shell model studies of spectroscopic properties of 64 Zn ...

    Indian Academy of Sciences (India)

    2014-04-05

    Apr 5, 2014 ... The spectroscopic properties of 64Zn and 64Ni are calculated within the framework of the deformed shell model (DSM) based on Hartree–Fock states. GXPF1A interaction in 1 f 7 / 2 , 2 p 3 / 2 , 1 f 5 / 2 and 2 p 1 / 2 space with 40Ca as the core is employed. After ensuring that DSM gives good description of ...

  11. THE TIME DOMAIN SPECTROSCOPIC SURVEY: VARIABLE SELECTION AND ANTICIPATED RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Morganson, Eric; Green, Paul J. [Harvard Smithsonian Center for Astrophysics, 60 Garden St, Cambridge, MA 02138 (United States); Anderson, Scott F.; Ruan, John J. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Myers, Adam D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Eracleous, Michael; Brandt, William Nielsen [Department of Astronomy and Astrophysics, 525 Davey Laboratory, The Pennsylvania State University, University Park, PA 16802 (United States); Kelly, Brandon [Department of Physics, Broida Hall, University of California, Santa Barbara, CA 93106-9530 (United States); Badenes, Carlos [Department of Physics and Astronomy and Pittsburgh Particle Physics, Astrophysics and Cosmology Center (PITT PACC), University of Pittsburgh, 3941 O’Hara St, Pittsburgh, PA 15260 (United States); Bañados, Eduardo [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanton, Michael R. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Bershady, Matthew A. [Department of Astronomy, University of Wisconsin, 475 N. Charter St., Madison, WI 53706 (United States); Borissova, Jura [Instituto de Física y Astronomía, Universidad de Valparaíso, Av. Gran Bretaña 1111, Playa Ancha, Casilla 5030, and Millennium Institute of Astrophysics (MAS), Santiago (Chile); Burgett, William S. [GMTO Corp, Suite 300, 251 S. Lake Ave, Pasadena, CA 91101 (United States); Chambers, Kenneth, E-mail: emorganson@cfa.harvard.edu [Institute for Astronomy, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); and others

    2015-06-20

    We present the selection algorithm and anticipated results for the Time Domain Spectroscopic Survey (TDSS). TDSS is an Sloan Digital Sky Survey (SDSS)-IV Extended Baryon Oscillation Spectroscopic Survey (eBOSS) subproject that will provide initial identification spectra of approximately 220,000 luminosity-variable objects (variable stars and active galactic nuclei across 7500 deg{sup 2} selected from a combination of SDSS and multi-epoch Pan-STARRS1 photometry. TDSS will be the largest spectroscopic survey to explicitly target variable objects, avoiding pre-selection on the basis of colors or detailed modeling of specific variability characteristics. Kernel Density Estimate analysis of our target population performed on SDSS Stripe 82 data suggests our target sample will be 95% pure (meaning 95% of objects we select have genuine luminosity variability of a few magnitudes or more). Our final spectroscopic sample will contain roughly 135,000 quasars and 85,000 stellar variables, approximately 4000 of which will be RR Lyrae stars which may be used as outer Milky Way probes. The variability-selected quasar population has a smoother redshift distribution than a color-selected sample, and variability measurements similar to those we develop here may be used to make more uniform quasar samples in large surveys. The stellar variable targets are distributed fairly uniformly across color space, indicating that TDSS will obtain spectra for a wide variety of stellar variables including pulsating variables, stars with significant chromospheric activity, cataclysmic variables, and eclipsing binaries. TDSS will serve as a pathfinder mission to identify and characterize the multitude of variable objects that will be detected photometrically in even larger variability surveys such as Large Synoptic Survey Telescope.

  12. A spectroscopic analysis of the chemically peculiar star HD 207561

    Science.gov (United States)

    Joshi, S.; Semenko, E.; Martinez, P.; Sachkov, M.; Joshi, Y. C.; Seetha, S.; Chakradhari, N. K.; Mary, D. L.; Girish, V.; Ashoka, B. N.

    2012-08-01

    In this paper we present a high-resolution spectroscopic analysis of the chemically peculiar star HD 207561. During a survey programme to search for new rapidly oscillating Ap (roAp) stars in the Northern hemisphere, Joshi et al. observed significant photometric variability on two consecutive nights in the year 2000. The amplitude spectra of the light curves obtained on these two nights showed oscillations with a frequency of 2.79 mHz (P ˜ 6 min). However, subsequent follow-up observations could not confirm any rapid variability. In order to determine the spectroscopic nature of HD 207561, high-resolution spectroscopic and spectropolarimetric observations were carried out. A reasonable fit of the calculated Hβ line profile to the observed one yields an effective temperature (Teff) and surface gravity (log g) of 7300 K and 3.7 dex, respectively. The derived projected rotational velocity (v sin i) for HD 207561 is 74 km s-1, indicative of a relatively fast rotator. The position of HD 207561 in the Hertzsprung-Russell diagram implies that this is slightly evolved from the main-sequence and located well within the δ-Scuti instability strip. The abundance analysis indicates the star has slight underabundances of Ca and Sc and mild overabundances of iron-peak elements. The spectropolarimetric study of HD 207561 shows that the effective magnetic field is within the observational error of 100 G. The spectroscopic analysis revealed that the star has most of the characteristics similar to an Am star, rather than an Ap star, and that it lies in the δ-Scuti instability strip; hence roAp pulsations are not expected in HD 207561, but low-overtone modes might be excited. The present work is based on the analysis of data collected with the Russian 6-m telescope BTA operated by the Special Astrophysical Observatory of the Russian Academy of Sciences (SAO RAS).

  13. 2D NMR-spectroscopic screening reveals polyketides in ladybugs

    OpenAIRE

    Deyrup, Stephen T.; Eckman, Laura E.; McCarthy, Patrick H.; Smedley, Scott R.; Meinwald, Jerrold; Schroeder, Frank C.

    2011-01-01

    Small molecules of biological origin continue to yield the most promising leads for drug design, but systematic approaches for exploring nature’s cache of structural diversity are lacking. Here, we demonstrate the use of 2D NMR spectroscopy to screen a library of biorationally selected insect metabolite samples for partial structures indicating the presence of new chemical entities. This NMR-spectroscopic survey enabled detection of novel compounds in complex metabolite mixtures without prior...

  14. Ion-beam spectroscopic studies of the 69As nucleus

    International Nuclear Information System (INIS)

    Badica, T.; Cojocaru, V.; Olariu, A.; Petre, M.; Popescu, I. V.; Gheboianu, A.

    2009-01-01

    Excited state of the neutron deficient 69 As nucleus were investigated in the 58 Ni( 14 N,2pn) reaction by ion-beam γ spectroscopic methods (excitation functions, γγ-coincidences, angular distributions and linear polarization gated with neutrons). A new more complete level scheme of 69 As has been proposed with spin-parity values. The structure of the nucleus is discussed in the framework of the interaction boson-fermion model (IBFM). (authors)

  15. Choosing the optimal spectroscopic toolkit to understand protein function.

    Science.gov (United States)

    Hough, Michael A

    2017-06-30

    Spectroscopy was one of the earliest methods used to study the properties and reactions of proteins, and remains one of the most powerful and widely used approaches to this day. A sometimes bewildering range of spectroscopies is now available, applicable to different sample states, timescales and indeed biological questions. This editorial describes some of the most relevant spectroscopic methods together with a selection of illustrative examples. © 2017 The Author(s).

  16. Optical Spectroscopic Observations of Cyg X-1 = HDE 226868

    Czech Academy of Sciences Publication Activity Database

    Yan, Y.; Liu, Q.; Hadrava, Petr

    2008-01-01

    Roč. 136, č. 2 (2008), s. 631-640 ISSN 0004-6256 R&D Projects: GA ČR GA202/06/0041; GA MŠk(CZ) LC06014 Institutional research plan: CEZ:AV0Z10030501 Keywords : binaries * spectroscopic * early-type stars Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.769, year: 2008

  17. Spectroscopic Tools for Quantitative Studies of DNA Structure and Dynamics

    DEFF Research Database (Denmark)

    Preus, Søren

    The main objective of this thesis is to develop quantitative fluorescence-based, spectroscopic tools for probing the 3D structure and dynamics of DNA and RNA. The thesis is founded on six peer-reviewed papers covering mainly the development, characterization and use of fluorescent nucleobase...... analogues. In addition, four software packages is presented for the simulation and quantitative analysis of time-resolved and steady-state UV-Vis absorption and fluorescence experiments....

  18. Spectroscopic and lasing properties of Ho:Tm:LuAG

    Science.gov (United States)

    Barnes, Norman P.; Filer, Elizabeth D.; Naranjo, Felipe L.; Rodriguez, Waldo J.; Kokta, Milan R.

    1993-01-01

    Ho:Tm:LuAG has been grown, examined spectroscopically, and lased at 2.1 microns. Ho:Tm:LuAG was selected for this experimental investigation when quantum-mechanical modeling predicted that it would be a good laser material for Ho laser operation on one of the 5I7 to 5I8 transitions. Lasing was achieved at 2.100 microns, one of the three wavelengths predicted to be most probable for laser action.

  19. Study of various spectroscopic properties of the Ds meson

    Directory of Open Access Journals (Sweden)

    Kher Virendrasinh H.

    2015-01-01

    Full Text Available Spectroscopic parameters of the Ds (cs̄ meson are obtained using phenomenological quark antiquark potential(coulomb plus power model consisting of O(1/m correction to the potential. Within Variational scheme Gaussian wave function is employed with a hamiltonian incorporating kinematic relativistic corrections to obtain various properties such as the mass spectra, decay constants, electromagnetic transitions. The results are compared with various experimental measurement as well as other theoretical predictions.

  20. Handbook of infrared standards II with spectral coverage between

    CERN Document Server

    Meurant, Gerard

    1993-01-01

    This timely compilation of infrared standards has been developed for use by infrared researchers in chemistry, physics, engineering, astrophysics, and laser and atmospheric sciences. Providing maps of closely spaced molecular spectra along with their measured wavenumbers between 1.4vm and 4vm, this handbook will complement the 1986 Handbook of Infrared Standards that included special coverage between 3 and 2600vm. It will serve as a necessary reference for all researchers conducting spectroscopic investigations in the near-infrared region.Key Features:- Provides all new spec

  1. THE BARYON OSCILLATION SPECTROSCOPIC SURVEY OF SDSS-III

    International Nuclear Information System (INIS)

    Dawson, Kyle S.; Ahn, Christopher P.; Bolton, Adam S.; Schlegel, David J.; Bailey, Stephen; Anderson, Scott F.; Bhardwaj, Vaishali; Aubourg, Éric; Bautista, Julian E.; Barkhouser, Robert H.; Beifiori, Alessandra; Berlind, Andreas A.; Bizyaev, Dmitry; Brewington, Howard; Blake, Cullen H.; Blanton, Michael R.; Blomqvist, Michael; Borde, Arnaud; Bovy, Jo; Brandt, W. N.

    2013-01-01

    The Baryon Oscillation Spectroscopic Survey (BOSS) is designed to measure the scale of baryon acoustic oscillations (BAO) in the clustering of matter over a larger volume than the combined efforts of all previous spectroscopic surveys of large-scale structure. BOSS uses 1.5 million luminous galaxies as faint as i = 19.9 over 10,000 deg 2 to measure BAO to redshifts z A to an accuracy of 1.0% at redshifts z = 0.3 and z = 0.57 and measurements of H(z) to 1.8% and 1.7% at the same redshifts. Forecasts for Lyα forest constraints predict a measurement of an overall dilation factor that scales the highly degenerate D A (z) and H –1 (z) parameters to an accuracy of 1.9% at z ∼ 2.5 when the survey is complete. Here, we provide an overview of the selection of spectroscopic targets, planning of observations, and analysis of data and data quality of BOSS.

  2. Spectroscopic amplifier for pin diode; Amplificador espectroscopico para diodo Pin

    Energy Technology Data Exchange (ETDEWEB)

    Alonso M, M. S.; Hernandez D, V. M.; Vega C, H. R., E-mail: bebe.luna_s@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The photodiode remains the basic choice for the photo-detection and is widely used in optical communications, medical diagnostics and field of corpuscular radiation. In detecting radiation it has been used for monitoring radon and its progeny and inexpensive spectrometric systems. The development of a spectroscopic amplifier for Pin diode is presented which has the following characteristics: canceler Pole-Zero (P/Z) with a time constant of 8 μs; constant gain of 57, suitable for the acquisition system; 4th integrator Gaussian order to waveform change of exponential input to semi-Gaussian output and finally a stage of baseline restorer which prevents Dc signal contribution to the next stage. The operational amplifier used is the TLE2074 of BiFET technology of Texas Instruments with 10 MHz bandwidth, 25 V/μs of slew rate and a noise floor of 17 nv/(Hz)1/2. The integrated circuit has 4 operational amplifiers and in is contained the total of spectroscopic amplifier that is the goal of electronic design. The results show like the exponential input signal is converted to semi-Gaussian, modifying only the amplitude according to the specifications in the design. The total system is formed by the detector, which is the Pin diode, a sensitive preamplifier to the load, the spectroscopic amplifier that is what is presented and finally a pulse height analyzer (Mca) which is where the spectrum is shown. (Author)

  3. Plant roots and spectroscopic methods - analyzing species, biomass and vitality.

    Science.gov (United States)

    Rewald, Boris; Meinen, Catharina

    2013-01-01

    In order to understand plant functioning, plant community composition, and terrestrial biogeochemistry, it is decisive to study standing root biomass, (fine) root dynamics, and interactions belowground. While most plant taxa can be identified by visual criteria aboveground, roots show less distinctive features. Furthermore, root systems of neighboring plants are rarely spatially segregated; thus, most soil horizons and samples hold roots of more than one species necessitating root sorting according to taxa. In the last decades, various approaches, ranging from anatomical and morphological analyses to differences in chemical composition and DNA sequencing were applied to discern species' identity and biomass belowground. Among those methods, a variety of spectroscopic methods was used to detect differences in the chemical composition of roots. In this review, spectroscopic methods used to study root systems of herbaceous and woody species in excised samples or in situ will be discussed. In detail, techniques will be reviewed according to their usability to discern root taxa, to determine root vitality, and to quantify root biomass non-destructively or in soil cores holding mixtures of plant roots. In addition, spectroscopic methods which may be able to play an increasing role in future studies on root biomass and related traits are highlighted.

  4. A convolutional neural network to filter artifacts in spectroscopic MRI.

    Science.gov (United States)

    Gurbani, Saumya S; Schreibmann, Eduard; Maudsley, Andrew A; Cordova, James Scott; Soher, Brian J; Poptani, Harish; Verma, Gaurav; Barker, Peter B; Shim, Hyunsuk; Cooper, Lee A D

    2018-03-09

    Proton MRSI is a noninvasive modality capable of generating volumetric maps of in vivo tissue metabolism without the need for ionizing radiation or injected contrast agent. Magnetic resonance spectroscopic imaging has been shown to be a viable imaging modality for studying several neuropathologies. However, a key hurdle in the routine clinical adoption of MRSI is the presence of spectral artifacts that can arise from a number of sources, possibly leading to false information. A deep learning model was developed that was capable of identifying and filtering out poor quality spectra. The core of the model used a tiled convolutional neural network that analyzed frequency-domain spectra to detect artifacts. When compared with a panel of MRS experts, our convolutional neural network achieved high sensitivity and specificity with an area under the curve of 0.95. A visualization scheme was implemented to better understand how the convolutional neural network made its judgement on single-voxel or multivoxel MRSI, and the convolutional neural network was embedded into a pipeline capable of producing whole-brain spectroscopic MRI volumes in real time. The fully automated method for assessment of spectral quality provides a valuable tool to support clinical MRSI or spectroscopic MRI studies for use in fields such as adaptive radiation therapy planning. © 2018 International Society for Magnetic Resonance in Medicine.

  5. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    Science.gov (United States)

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  6. New insight into the observation of spectroscopic strength reduction in atomic nuclei: implication for the physical meaning of spectroscopic factors.

    Science.gov (United States)

    Timofeyuk, N K

    2009-12-11

    Experimental studies of one-nucleon knockout from magic nuclei suggest that their nucleon orbits are not fully occupied. This conflicts a commonly accepted view of the shell closure associated with such nuclei. The conflict can be reconciled if the overlap between initial and final nuclear states in a knockout reaction are calculated by a nonstandard method. The method employs an inhomogeneous equation based on correlation-dependent effective nucleon-nucleon interactions and allows the simplest wave functions, in which all nucleons occupy only the lowest nuclear orbits, to be used. The method also reproduces the recently established relation between reduction of spectroscopic strength, observed in knockout reactions on other nuclei, and nucleon binding energies. The implication of the inhomogeneous equation method for the physical meaning of spectroscopic factors is discussed.

  7. Near infrared spectroscopic imaging assessment of cartilage composition: Validation with mid infrared imaging spectroscopy.

    Science.gov (United States)

    Palukuru, Uday P; Hanifi, Arash; McGoverin, Cushla M; Devlin, Sean; Lelkes, Peter I; Pleshko, Nancy

    2016-07-05

    Disease or injury to articular cartilage results in loss of extracellular matrix components which can lead to the development of osteoarthritis (OA). To better understand the process of disease development, there is a need for evaluation of changes in cartilage composition without the requirement of extensive sample preparation. Near infrared (NIR) spectroscopy is a chemical investigative technique based on molecular vibrations that is increasingly used as an assessment tool for studying cartilage composition. However, the assignment of specific molecular vibrations to absorbance bands in the NIR spectrum of cartilage, which arise from overtones and combinations of primary absorbances in the mid infrared (MIR) spectral region, has been challenging. In contrast, MIR spectroscopic assessment of cartilage is well-established, with many studies validating the assignment of specific bands present in MIR spectra to specific molecular vibrations. In the current study, NIR imaging spectroscopic data were obtained for compositional analysis of tissues that served as an in vitro model of OA. MIR spectroscopic data obtained from the identical tissue regions were used as the gold-standard for collagen and proteoglycan (PG) content. MIR spectroscopy in transmittance mode typically requires a much shorter pathlength through the sample (≤10 microns thick) compared to NIR spectroscopy (millimeters). Thus, this study first addressed the linearity of small absorbance bands in the MIR region with increasing tissue thickness, suitable for obtaining a signal in both the MIR and NIR regions. It was found that the linearity of specific, small MIR absorbance bands attributable to the collagen and PG components of cartilage (at 1336 and 856 cm(-1), respectively) are maintained through a thickness of 60 μm, which was also suitable for NIR data collection. MIR and NIR spectral data were then collected from 60 μm thick samples of cartilage degraded with chondroitinase ABC as a model

  8. Standards for Standardized Logistic Regression Coefficients

    Science.gov (United States)

    Menard, Scott

    2011-01-01

    Standardized coefficients in logistic regression analysis have the same utility as standardized coefficients in linear regression analysis. Although there has been no consensus on the best way to construct standardized logistic regression coefficients, there is now sufficient evidence to suggest a single best approach to the construction of a…

  9. Feasibility and reproducibility of echo planar spectroscopic imaging on the quantification of hepatic fat.

    Directory of Open Access Journals (Sweden)

    Yi-Ru Lin

    Full Text Available 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC. When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI on the quantification of HFC in subject with various HFCs.Twenty two volunteers were examined in a 3T MR system. The acquisition time of proposed EPSI protocol was 18 seconds. The EPSI scans were repeated 8 times for each subject to test reproducibility. The peak of water and individual peaks of fat including methyl, methylene, and allylic peaks at 0.9, 1.3, and 2.0 ppm were fitted. Calculated amount of water and fat content were corrected for T2 relaxation. The total HFC was defined as the combination of individual peaks. Standard deviation (SD, coefficient of variance (COV and fitting reliability of HFC quantified by LCModel were calculated.Our results show that the SDs of total HFC for all subjects are less than 2.5%. Fitting reliability is mostly under 10% and positively correlates with COV. Subjects separated into three subgroups according to quantified total HFC show that improved fitting reliability and reproducibility can be achieved on subjects with higher total HFC.We have demonstrated feasibility of the proposed EPSI protocols on the quantification of HFC over a whole slice of liver with scan time in a single breath hold.

  10. Spectroscopic detection, characterization and dynamics of free radicals relevant to combustion processes

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Terry [The Ohio State Univ., Columbus, OH (United States)

    2015-06-04

    Combustion chemistry is enormously complex. The chemical mechanisms involve a multitude of elementary reaction steps and a comparable number of reactive intermediates, many of which are free radicals. Computer simulations based upon these mechanisms are limited by the validity of the mechanisms and the parameters characterizing the properties of the intermediates and their reactivity. Spectroscopy can provide data for sensitive and selective diagnostics to follow their reactions. Spectroscopic analysis also provides detailed parameters characterizing the properties of these intermediates. These parameters serve as experimental gold standards to benchmark predictions of these properties from large-scale, electronic structure calculations. This work has demonstrated the unique capabilities of near-infrared cavity ringdown spectroscopy (NIR CRDS) to identify, characterize and monitor intermediates of key importance in complex chemical reactions. Our studies have focussed on the large family of organic peroxy radicals which are arguably themost important intermediates in combustion chemistry and many other reactions involving the oxidation of organic compounds. Our spectroscopic studies have shown that the NIR Ã - ˜X electronic spectra of the peroxy radicals allows one to differentiate among chemical species in the organic peroxy family and also determine their isomeric and conformic structure in many cases. We have clearly demonstrated this capability on saturated and unsaturated peroxy radicals and β-hydroxy peroxy radicals. In addition we have developed a unique dual wavelength CRDS apparatus specifically for the purpose of measuring absolute absorption cross section and following the reaction of chemical intermediates. The utility of the apparatus has been demonstrated by measuring the cross-section and self-reaction rate constant for ethyl peroxy.

  11. Automatic diagnosis of melanoma using machine learning methods on a spectroscopic system.

    Science.gov (United States)

    Li, Lin; Zhang, Qizhi; Ding, Yihua; Jiang, Huabei; Thiers, Bruce H; Wang, James Z

    2014-10-13

    Early and accurate diagnosis of melanoma, the deadliest type of skin cancer, has the potential to reduce morbidity and mortality rate. However, early diagnosis of melanoma is not trivial even for experienced dermatologists, as it needs sampling and laboratory tests which can be extremely complex and subjective. The accuracy of clinical diagnosis of melanoma is also an issue especially in distinguishing between melanoma and mole. To solve these problems, this paper presents an approach that makes non-subjective judgements based on quantitative measures for automatic diagnosis of melanoma. Our approach involves image acquisition, image processing, feature extraction, and classification. 187 images (19 malignant melanoma and 168 benign lesions) were collected in a clinic by a spectroscopic device that combines single-scattered, polarized light spectroscopy with multiple-scattered, un-polarized light spectroscopy. After noise reduction and image normalization, features were extracted based on statistical measurements (i.e. mean, standard deviation, mean absolute deviation, L1 norm, and L2 norm) of image pixel intensities to characterize the pattern of melanoma. Finally, these features were fed into certain classifiers to train learning models for classification. We adopted three classifiers - artificial neural network, naïve bayes, and k-nearest neighbour to evaluate our approach separately. The naive bayes classifier achieved the best performance - 89% accuracy, 89% sensitivity and 89% specificity, which was integrated with our approach in a desktop application running on the spectroscopic system for diagnosis of melanoma. Our work has two strengths. (1) We have used single scattered polarized light spectroscopy and multiple scattered unpolarized light spectroscopy to decipher the multilayered characteristics of human skin. (2) Our approach does not need image segmentation, as we directly probe tiny spots in the lesion skin and the image scans do not involve

  12. Perturbed Angular Correlation (PAC)/NMR spectroscopic properties and dynamics of compounds containing metal ions

    DEFF Research Database (Denmark)

    Arcisauskaité, Vaida

    in proteins: • ZORA-4/BH&H for 199mHg PAC spectroscopic properties, • ZORA/BH&HLYP for 199Hg NMR spectroscopic properties. By using these methods we further examined in Section 6.5 the influence of the immediate crystal environment on these spectroscopic properties and concluded that it does matter, in some......199mHg PAC and 199Hg NMR spectroscopic properties, nuclear quadrupole coupling constants, Q, asymmetry parameters, , and chemical shifts, , respectively, are the fingerprint of the local molecular and electronic structure, at the probed Hg nuclei. For this reason, these spectroscopic techniques...... have been used to elucidate Hg coordination in proteins. Computational chemistry calculations have a potential to contribute to the interpretation of this spectroscopic data, as calculated diagonalised electric field gradient (EFG) tensor components (jVzzj jVyyj jVxxj) and NMR shielding constants...

  13. Malaysian NDT standards

    International Nuclear Information System (INIS)

    Khazali Mohd Zin

    2001-01-01

    In order to become a developed country, Malaysia needs to develop her own national standards. It has been projected that by the year 2020, Malaysia requires about 8,000 standards (Department of Standard Malaysia). Currently more than 2,000 Malaysian Standards have been gazette by the government which considerably too low before tire year 2020. NDT standards have been identified by the standard working group as one of the areas to promote our national standards. In this paper the author describes the steps taken to establish the Malaysian very own NDT standards. The project starts with the establishment of radiographic standards. (Author)

  14. Theoretical studies on CH+ ion molecule using configuration interaction method and its spectroscopic properties

    International Nuclear Information System (INIS)

    Machado, F.B.C.

    1985-01-01

    The use of the configuration (CI) method for the calculation of very accurate potential energy curves and dipole moment functions, and then their use in the comprehension of spectroscopic properties of diatomic molecules is presented. The spectroscopic properties of CH + and CD + such as: vibrational levels, spectroscopic constants, averaged dipole moments for all vibrational levels, radiative transition probabilities for emission and absorption, and radiative lifetimes are verificated. (M.J.C.) [pt

  15. Microsecond Scale Vibrational Spectroscopic Imaging by Multiplex Stimulated Raman Scattering Microscopy

    OpenAIRE

    Liao, Chien-Sheng; Slipchenko, Mikhail N.; Wang, Ping; Li, Junjie; Lee, Seung-Young; Oglesbee, Robert A.; Cheng, Ji-Xin

    2015-01-01

    Real-time vibrational spectroscopic imaging is desired for monitoring cellular states and cellular processes in a label-free manner. Raman spectroscopic imaging of highly dynamic systems is inhibited by relatively slow spectral acquisition on millisecond to second scale. Here, we report microsecond scale vibrational spectroscopic imaging by lock-in free parallel detection of spectrally dispersed stimulated Raman scattering signal. Using a homebuilt tuned amplifier array, our method enables Ra...

  16. Performance assessment of diffuse optical spectroscopic imaging instruments in a 2-year multicenter breast cancer trial

    Science.gov (United States)

    Leproux, Anaïs; O'Sullivan, Thomas D.; Cerussi, Albert; Durkin, Amanda; Hill, Brian; Hylton, Nola; Yodh, Arjun G.; Carp, Stefan A.; Boas, David; Jiang, Shudong; Paulsen, Keith D.; Pogue, Brian; Roblyer, Darren; Yang, Wei; Tromberg, Bruce J.

    2017-12-01

    We present a framework for characterizing the performance of an experimental imaging technology, diffuse optical spectroscopic imaging (DOSI), in a 2-year multicenter American College of Radiology Imaging Network (ACRIN) breast cancer study (ACRIN-6691). DOSI instruments combine broadband frequency-domain photon migration with time-independent near-infrared (650 to 1000 nm) spectroscopy to measure tissue absorption and reduced scattering spectra and tissue hemoglobin, water, and lipid composition. The goal of ACRIN-6691 was to test the effectiveness of optically derived imaging endpoints in predicting the final pathologic response of neoadjuvant chemotherapy (NAC). Sixty patients were enrolled over a 2-year period at participating sites and received multiple DOSI scans prior to and during 3- to 6-month NAC. The impact of three sources of error on accuracy and precision, including different operators, instruments, and calibration standards, was evaluated using a broadband reflectance standard and two different solid tissue-simulating optical phantoms. Instruments showed <0.0010 mm-1 (10.3%) and 0.06 mm-1 (4.7%) deviation in broadband absorption and reduced scattering, respectively, over the 2-year duration of ACRIN-6691. These variations establish a useful performance criterion for assessing instrument stability. The proposed procedures and tests are not limited to DOSI; rather, they are intended to provide methods to characterize performance of any instrument used in translational optical imaging.

  17. Spectroscopic Methods of Remote Sensing for Vegetation Characterization

    Science.gov (United States)

    Kokaly, R. F.

    2013-12-01

    Imaging spectroscopy (IS), often referred to as hyperspectral remote sensing, is one of the latest innovations in a very long history of spectroscopy. Spectroscopic methods have been used for understanding the composition of the world around us, as well as, the solar system and distant parts of the universe. Continuous sampling of the electromagnetic spectrum in narrow bands is what separates IS from previous forms of remote sensing. Terrestrial imaging spectrometers often have hundreds of channels that cover the wavelength range of reflected solar radiation, including the visible, near-infrared (NIR), and shortwave infrared (SWIR) regions. In part due to the large number of channels, a wide variety of methods have been applied to extract information from IS data sets. These can be grouped into several broad classes, including: multi-channel indices, statistical procedures, full spectrum mixing models, and spectroscopic methods. Spectroscopic methods carry on the more than 150 year history of laboratory-based spectroscopy applied to material identification and characterization. Spectroscopic methods of IS relate the positions and shapes of spectral features resolved by airborne and spaceborne sensors to the biochemical and physical composition of vegetation in a pixel. The chlorophyll 680nm, water 980nm, water 1200nm, SWIR 1700nm, SWIR 2100nm, and SWIR 2300nm features have been the subject of study. Spectral feature analysis (SFA) involves isolating such an absorption feature using continuum removal (CR) and calculating descriptors of the feature, such as center position, depth, width, area, and asymmetry. SFA has been applied to quantify pigment and non-pigment biochemical concentrations in leaves, plants, and canopies. Spectral feature comparison (SFC) utilizes CR of features in each pixel's spectrum and linear regression with continuum-removed features in reference spectra in a library of known vegetation types to map vegetation species and communities. SFC has

  18. Spectroscopic failures in photometric redshift calibration: cosmological biases and survey requirements

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Carlos E. [KIPAC, Menlo Park; Huterer, Dragan [Michigan U.; Lin, Huan [Fermilab; Busha, Michael T. [Zurich U.; Wechsler, Risa H. [SLAC

    2014-10-11

    We use N-body-spectro-photometric simulations to investigate the impact of incompleteness and incorrect redshifts in spectroscopic surveys to photometric redshift training and calibration and the resulting effects on cosmological parameter estimation from weak lensing shear-shear correlations. The photometry of the simulations is modeled after the upcoming Dark Energy Survey and the spectroscopy is based on a low/intermediate resolution spectrograph with wavelength coverage of 5500{\\AA} < {\\lambda} < 9500{\\AA}. The principal systematic errors that such a spectroscopic follow-up encounters are incompleteness (inability to obtain spectroscopic redshifts for certain galaxies) and wrong redshifts. Encouragingly, we find that a neural network-based approach can effectively describe the spectroscopic incompleteness in terms of the galaxies' colors, so that the spectroscopic selection can be applied to the photometric sample. Hence, we find that spectroscopic incompleteness yields no appreciable biases to cosmology, although the statistical constraints degrade somewhat because the photometric survey has to be culled to match the spectroscopic selection. Unfortunately, wrong redshifts have a more severe impact: the cosmological biases are intolerable if more than a percent of the spectroscopic redshifts are incorrect. Moreover, we find that incorrect redshifts can also substantially degrade the accuracy of training set based photo-z estimators. The main problem is the difficulty of obtaining redshifts, either spectroscopically or photometrically, for objects at z > 1.3. We discuss several approaches for reducing the cosmological biases, in particular finding that photo-z error estimators can reduce biases appreciably.

  19. Spectroscopic properties of highly Nd-doped lead phosphate glass

    Energy Technology Data Exchange (ETDEWEB)

    Novais, A.L.F. [Instituto de Física, Universidade Federal de Alagoas, Grupo de Fotônica e Fluidos Complexos, 57072-970 Maceió, AL (Brazil); Dantas, N.O. [Laboratório de Novos Materiais Isolantes e Semicondutores (LNMIS), Instituto de Física, Universidade Federal de Uberlândia, 38400-902 Uberlândia, MG (Brazil); Guedes, I. [Departamento de Física, Universidade Federal do Ceará, Campus do PICI, Caixa Postal 6030, 60455-760 Fortaleza, CE (Brazil); Vermelho, M.V.D., E-mail: vermelho@fis.ufal.br [Instituto de Física, Universidade Federal de Alagoas, Grupo de Fotônica e Fluidos Complexos, 57072-970 Maceió, AL (Brazil)

    2015-11-05

    The spectroscopic characteristics of highly Nd{sup 3+}-doped lead phosphate glasses (xNd:Pb{sub 3}(PO{sub 4}){sub 2}) have been investigated. The X-ray spectra show that the matrices are glassy up to 25 wt% of Nd{sup 3+} doping. From the Judd–Ofelt analysis we observe that while the Ω{sub (2)} parameter remains constant indicating that the 4f{sup N} and 4f{sup N−1}5 d{sup 1} configurations are not affected by the Nd{sup 3+} doping, the behavior of both Ω{sub (4)} and Ω{sub (6)} changes for 15 wt% of Nd{sup 3+} doping. The reduction of the Ω{sub (6)} parameter is related to the increase of the covalence bonding between the ligands and the Nd{sup 3+} ions. At this particular concentration, the radiative lifetime has a four-fold enhancement. Such behaviors are likely to be related to a modification in the glass structure for high Nd{sup 3+} concentrations. - Graphical abstract: Highly doped lead-phosphate glass matrix, with nominal concentration of up to 25 wt%, maintain the spectroscopic properties without deterioration. The analysis concerning the point of view of Nd{sup 3+} ions showed that high concentrations only affects the rare earth electronic charge density distribution. - Highlights: • Spectroscopic characterization of Nd{sub 2}O{sub 3} highly doped lead phosphate glasses. • Phosphate glass doped with Nd{sup 3+} for applications in photonic devices. • Judd–Ofelt analysis in phosphate glasses doped with Neodymium.

  20. New Developments of Broadband Cavity Enhanced Spectroscopic Techniques

    Science.gov (United States)

    Walsh, A.; Zhao, D.; Linnartz, H.; Ubachs, W.

    2013-06-01

    In recent years, cavity enhanced spectroscopic techniques, such as cavity ring-down spectroscopy (CRDS), cavity enhanced absorption spectroscopy (CEAS), and broadband cavity enhanced absorption spectroscopy (BBCEAS), have been widely employed as ultra-sensitive methods for the measurement of weak absorptions and in the real-time detection of trace species. In this contribution, we introduce two new cavity enhanced spectroscopic concepts: a) Optomechanical shutter modulated BBCEAS, a variant of BBCEAS capable of measuring optical absorption in pulsed systems with typically low duty cycles. In conventional BBCEAS applications, the latter substantially reduces the signal-to-noise ratio (S/N), consequently also reducing the detection sensitivity. To overcome this, we incorporate a fast optomechanical shutter as a time gate, modulating the detection scheme of BBCEAS and increasing the effective duty cycle reaches a value close to unity. This extends the applications of BBCEAS into pulsed samples and also in time-resolved studies. b) Cavity enhanced self-absorption spectroscopy (CESAS), a new spectroscopic concept capable of studying light emitting matter (plasma, flames, combustion samples) simultaneously in absorption and emission. In CESAS, a sample (plasma, flame or combustion source) is located in an optically stable cavity consisting of two high reflectivity mirrors, and here it acts both as light source and absorbing medium. A high detection sensitivity of weak absorption is reached without the need of an external light source, such as a laser or broadband lamp. The performance is illustrated by the first CESAS result on a supersonically expanding hydrocarbon plasma. We expect CESAS to become a generally applicable analytical tool for real time and in situ diagnostics. A. Walsh, D. Zhao, W. Ubachs, H. Linnartz, J. Phys. Chem. A, {dx.doi.org/10.1021/jp310392n}, in press, 2013. A. Walsh, D. Zhao, H. Linnartz Rev. Sci. Instrum. {84}(2), 021608 2013. A. Walsh, D. Zhao

  1. Spectroscopic studies of the cytochrome P450 reaction mechanisms.

    Science.gov (United States)

    Mak, Piotr J; Denisov, Ilia G

    2018-01-01

    The cytochrome P450 monooxygenases (P450s) are thiolate heme proteins that can, often under physiological conditions, catalyze many distinct oxidative transformations on a wide variety of molecules, including relatively simple alkanes or fatty acids, as well as more complex compounds such as steroids and exogenous pollutants. They perform such impressive chemistry utilizing a sophisticated catalytic cycle that involves a series of consecutive chemical transformations of heme prosthetic group. Each of these steps provides a unique spectral signature that reflects changes in oxidation or spin states, deformation of the porphyrin ring or alteration of dioxygen moieties. For a long time, the focus of cytochrome P450 research was to understand the underlying reaction mechanism of each enzymatic step, with the biggest challenge being identification and characterization of the powerful oxidizing intermediates. Spectroscopic methods, such as electronic absorption (UV-Vis), electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), electron nuclear double resonance (ENDOR), Mössbauer, X-ray absorption (XAS), and resonance Raman (rR), have been useful tools in providing multifaceted and detailed mechanistic insights into the biophysics and biochemistry of these fascinating enzymes. The combination of spectroscopic techniques with novel approaches, such as cryoreduction and Nanodisc technology, allowed for generation, trapping and characterizing long sought transient intermediates, a task that has been difficult to achieve using other methods. Results obtained from the UV-Vis, rR and EPR spectroscopies are the main focus of this review, while the remaining spectroscopic techniques are briefly summarized. This article is part of a Special Issue entitled: Cytochrome P450 biodiversity and biotechnology, edited by Erika Plettner, Gianfranco Gilardi, Luet Wong, Vlada Urlacher, Jared Goldstone. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Weighted averaging in spectroscopic studies improves statistical power

    OpenAIRE

    Miller, JJ; Cochlin, L; Clarke, K; Tyler, D

    2017-01-01

    Purpose In vivo MRS is often characterized by a spectral signal‐to‐noise ratio (SNR) that varies highly between experiments. A common design for spectroscopic studies is to compare the ratio of two spectral peak amplitudes between groups, e.g. individual PCr/γ‐ATP ratios in 31P‐MRS. The uncertainty on this ratio is often neglected. We wished to explore this assumption. Theory The canonical theory for the propagation of uncertainty on the ratio of two spectral peaks and its incorporation in th...

  3. Spectroscopic Search for Atmospheric Signatures of Extra-solar Planets

    Science.gov (United States)

    Rauer, Heike; Harris, Alan; Collier Cameron, A.; Export-Team

    If the orbital inclination of an extra-solar planet is close to 90o, the planet will transit through the line-of-sight from Earth towards the star. During transit phases, the stellar light will pass through the planetary atmosphere, and absorption lines, caused by atoms/molecules in the planet's atmosphere, may be detected in high-resolution spectroscopic observations. We have searched for absorption features in spectra of 51 Peg, τ Boo and HD209458 during transits of their planets through the lines of sight. Spectra in the optical wavelength range were taken using the UES spectrograph at the 4m William Herschel telescope at La Palma, Spain.

  4. Spectroscopic Tools Applied to Element Z = 115 Decay Chains

    Directory of Open Access Journals (Sweden)

    Forsberg U.

    2014-03-01

    Full Text Available Nuclides that are considered to be isotopes of element Z = 115 were produced in the reaction 48Ca + 243Am at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt. The detector setup TASISpec was used. It was mounted behind the gas-filled separator TASCA. Thirty correlated α-decay chains were found, and the energies of the particles were determined with high precision. Two important spectroscopic aspects of the offline data analysis are discussed in detail: the handling of digitized preamplified signals from the silicon strip detectors, and the energy reconstruction of particles escaping to upstream detectors relying on pixel-by-pixel dead-layer thicknesses.

  5. Method of absorbance correction in a spectroscopic heating value sensor

    Science.gov (United States)

    Saveliev, Alexei; Jangale, Vilas Vyankatrao; Zelepouga, Sergeui; Pratapas, John

    2013-09-17

    A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

  6. Surveying RFI for a new Brazilian Solar Spectroscope site

    Science.gov (United States)

    Cecatto, José R.; Albuquerque, Paulo C. G.; Vila, Ivan O. G.; Cassiano, Alan B.; Strauss, César; Fernandes, Francisco C. R.

    2010-02-01

    Brazilian Solar Spectroscope (BSS) carry out high time (0.01-0.1 s) resolution solar spectral investigations within the frequency range 1-2.5 GHz on a daily basis. At the moment, a new site is imposed to this facility. This site change became necessary due to both factors: the growing level of radio frequency interference (RFI) signals at actual site and requirements of rising up a new building at the BSS antenna location. We present results of RFI signals search at INPE-Cachoeira Paulista area as purpose to define a new BSS site.

  7. Novel spectroscopic techniques with using soft x-ray

    International Nuclear Information System (INIS)

    Gejo, Tatsuo

    2010-01-01

    Recent progress of experimental techniques related to synchrotron radiation makes possible of detail investigation of molecular dynamics after irradiation of soft X-ray. We introduce several novel spectroscopic techniques with using soft X-ray: Symmetry-resolved zero kinetic energy electron spectroscopy, symmetry-resolved metastable photofragment spectroscopy, soft X-ray emission spectroscopy, time-resolved fluorescence spectroscopy, and time-resolved-fluorescence mass-selected-ion coincidence spectroscopy. We also show new techniques performed by other groups at BL27SU in SPring-8. (author)

  8. Spectroscopic and dynamical studies of highly energized small polyatomic molecules

    Energy Technology Data Exchange (ETDEWEB)

    Field, R.W.; Silbey, R.J. [Massachusetts Institute of Technology, Cambridge (United States)

    1993-12-01

    The authors have initiated a program to perform spectroscopic and dynamic studies of small molecules. Large amplitude motions in excited acetylene were discussed along with plans to record the dispersed fluorescence (DF) and the stimulated emission pumping (SEP) spectra. SEP spectra were reported for the formyl radical. A Fourier transform spectrometer was discussed with respect to its ability to probe the structure of radicals. This instrument is capable of performing studies using various techniques such as magnetic rotation spectroscopy and sub-Doppler sideband-OODR Zeman (SOODRZ) spectroscopy.

  9. Fitting by Orthonormal Polynomials of Silver Nanoparticles Spectroscopic Data

    Science.gov (United States)

    Bogdanova, Nina; Koleva, Mihaela

    2018-02-01

    Our original Orthonormal Polynomial Expansion Method (OPEM) in one-dimensional version is applied for first time to describe the silver nanoparticles (NPs) spectroscopic data. The weights for approximation include experimental errors in variables. In this way we construct orthonormal polynomial expansion for approximating the curve on a non equidistant point grid. The corridors of given data and criteria define the optimal behavior of searched curve. The most important subinterval of spectra data is investigated, where the minimum (surface plasmon resonance absorption) is looking for. This study describes the Ag nanoparticles produced by laser approach in a ZnO medium forming a AgNPs/ZnO nanocomposite heterostructure.

  10. Mueller matrix spectroscopic ellipsometry study of chiral nanocrystalline cellulose films

    Science.gov (United States)

    Mendoza-Galván, Arturo; Muñoz-Pineda, Eloy; Ribeiro, Sidney J. L.; Santos, Moliria V.; Järrendahl, Kenneth; Arwin, Hans

    2018-02-01

    Chiral nanocrystalline cellulose (NCC) free-standing films were prepared through slow evaporation of aqueous suspensions of cellulose nanocrystals in a nematic chiral liquid crystal phase. Mueller matrix (MM) spectroscopic ellipsometry is used to study the polarization and depolarization properties of the chiral films. In the reflection mode, the MM is similar to the matrices reported for the cuticle of some beetles reflecting near circular left-handed polarized light in the visible range. The polarization properties of light transmitted at normal incidence for different polarization states of incident light are discussed. By using a differential decomposition of the MM, the structural circular birefringence and dichroism of a NCC chiral film are evaluated.

  11. Spectroscopic properties of vitamin E models in solution

    Science.gov (United States)

    Oliveira, L. B. A.; Colherinhas, G.; Fonseca, T. L.; Castro, M. A.

    2015-05-01

    We investigate the first absorption band and the 13C and 17O magnetic shieldings of vitamin E models in chloroform and in water using the S-MC/QM methodology in combination with the TD-DFT and GIAO approaches. The results show that the solvent effects on these spectroscopic properties are small but a proper description of the solvent shift for 17O magnetic shielding of the hydroxyl group in water requires the use of explicit solute-solvent hydrogen bonds. In addition, the effect of the replacement of hydrogen atoms by methyl groups in the vitamin E models only affects magnetic shieldings.

  12. Spectroscopic Feedback for High Density Data Storage and Micromachining

    Science.gov (United States)

    Carr, Christopher W.; Demos, Stavros; Feit, Michael D.; Rubenchik, Alexander M.

    2008-09-16

    Optical breakdown by predetermined laser pulses in transparent dielectrics produces an ionized region of dense plasma confined within the bulk of the material. Such an ionized region is responsible for broadband radiation that accompanies a desired breakdown process. Spectroscopic monitoring of the accompanying light in real-time is utilized to ascertain the morphology of the radiated interaction volume. Such a method and apparatus as presented herein, provides commercial realization of rapid prototyping of optoelectronic devices, optical three-dimensional data storage devices, and waveguide writing.

  13. Photometric and Spectroscopic studies of Ap star Cyg V1584

    Directory of Open Access Journals (Sweden)

    D. M. Z Jassur

    2001-06-01

    Full Text Available   UBV photometric observations of Ap star Cyg V1584 have been presented. To find the rotational period of the star, a sinusoidal wave function has been fitted to the noramal points of UBV filters. Assuming that a circular hot spot located at the magnetic pole of the star is responsible for the observed light variations, both physical an geometrical parameters of the spot have been determined. Finally, the angle between the magnetic and the rotational axis has been calculated from combining the spectroscopic and photometric data and the magnetic structure of the star has been discussed.

  14. Spectroscopic characterization of uranium in evaporation basin sediments

    Science.gov (United States)

    Duff, M. C.; Morris, D. E.; Hunter, D. B.; Bertsch, P. M.

    2000-05-01

    Evaporation ponds in the San Joaquin Valley (SJV), CA, used for the containment of irrigation drainage waters contain elevated levels of uranium (U) resulting from the extensive leaching by carbonate-rich irrigation waters of the local agricultural soils that contain low levels of naturally-occurring U. The SJV ponds are subjected to changes in redox chemistry with cycles of drying and flooding. Our past studies have shown that U in the SJV Pond 14 surface sediments is present as mostly the oxidized and soluble form, U(VI). However, we were uncertain whether the U in the soil was only present as a U oxide of mixed stoichiometry, such as U 3O 8(s) (pitchblende) or other species. Here we present characterization information, which includes wet chemical and in situ spectroscopic techniques (X-ray absorption near-edge structure (XANES) and low temperature time-resolved luminescence spectroscopies) for samples from two SJV Pond sediments. Surface sediments from SJV Pond 16 were characterized for average oxidation state of U with XANES spectroscopy. The fraction of U(VI) to U(IV) in the Pond 16 sediments decreased with depth with U(IV) being the dominant oxidation state in the 5 cm to 15 cm depth. Two luminescent U(VI) species were identified in the surface sediments from Pond 14; a U(VI)-tricarbonate phase and another phase likely comprised of U(VI)-hydroxide or hydroxycarbonate. The luminescent U(VI) population in the Pond 16 sediments is dominated by species with comparable spectral characteristics to the U(VI)-hydroxide or hydroxycarbonate species found in the Pond 14 sediments. The luminescence spectroscopic results were complemented by wet chemical U leaching methods, which involved the use of carbonate and sulfuric acid solutions and oxidizing solutions of peroxide, hypochlorite and Mn(IV). Leaching was shown to decrease the total U concentration in the sediments in all cases. However, results from luminescence studies of the residual fraction in the leached

  15. Scanning Tunneling Microscopy methods for spectroscopic imaging of subsurface interfaces

    Science.gov (United States)

    Bell, L. D.; Kaiser, W. J.

    1988-01-01

    A new method for spatially-resolved, spectroscopic investigation of subsurface interface structure has been developed. The method, Ballistic Electron Emission Microscopy (BEEM), is based on Scanning Tunneling Microscopy (STM) techniques. BEEM combines STM vacuum tunneling with unique ballistic electron spectroscopy capabilities. BEEM enables, for the first time, direct imaging of subsurface interface electronic properties with nanometer spatial resolution. STM topographic images of surface structure and BEEM images of subsurface properties are obtained simultaneously. BEEM capabilities are demonstrated by investigation of important metal-semiconductor interfaces.

  16. The International Standards Organisation offshore structures standard

    International Nuclear Information System (INIS)

    Snell, R.O.

    1994-01-01

    The International Standards Organisation has initiated a program to develop a suite of ISO Codes and Standards for the Oil Industry. The Offshore Structures Standard is one of seven topics being addressed. The scope of the standard will encompass fixed steel and concrete structures, floating structures, Arctic structures and the site specific assessment of mobile drilling and accommodation units. The standard will use as base documents the existing recommended practices and standards most frequently used for each type of structure, and will develop them to incorporate best published and recognized practice and knowledge where it provides a significant improvement on the base document. Work on the Code has commenced under the direction of an internationally constituted sub-committee comprising representatives from most of the countries with a substantial offshore oil and gas industry. This paper outlines the background to the code and the format, content and work program

  17. What is "Standard" About the Standard Deviation

    OpenAIRE

    Newberger, Florence; Safer, Alan M.; Watson, Saleem

    2010-01-01

    The choice of the formula for standard deviation is explained in elementary statistics textbooks in various ways. We give an explanation for this formula by representing the data as a vector in $\\mathbb R^n$ and considering its distance from a central tendency vector. In this setting the "standard" formula represents a shortest distance in the standard metric. We also show that different metrics lead to different measures of central tendency.

  18. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  19. Proton MR spectroscopic features of liver cirrhosis : comparing with normal liver

    International Nuclear Information System (INIS)

    Cho, Soon Gu; Choi, Won; Kim, Young Soo; Kim, Mi Young; Jee, Keum Nahn; Lee, Kyung Hee; Suh, Chang Hae

    2000-01-01

    The purpose of this study was to determine the proton MR spectroscopic features of liver cirrhosis and the different proton MR spectroscopic features between liver cirrhosis and the normal human liver by comparing the two different conditions. The investigation involved 30 cases of in-vivo proton MR spectra obtained from 15 patients with liver cirrhosis demonstrated on the basis of radiologic and clinical findings, and from 15 normal volunteers without a past or current history of liver disease. MR spectroscopy involved the use of 1.5T GESigna Horizon system (GE Medical Systems, Milwaukee, U. S. A.) with body coil. STEAM (STimulated Echo-Acquisition Mode) with 3000/30 msec of TR/TE was used for signal acquisition; patients were in the prone position and respiration was not interrupted. Cases were assigned to either the cirrhosis or normal group, and using the proton MR spectra of cases of in each group, peak changes occurring in lipids (at 1.3 ppm), glutamate and glutamine (at 2.4-2.5 ppm), phosphomonoesters (at 3.0-3.1 ppm), and glycogen and glucose (at 3.4-3.9 ppm) were evaluated. Mean and standard deviation of the ratio of glutamate + glutamine/lipids, phosphomonoesters/lipids, glycogen + glucose/lipids were calculated from the area of their peaks. The ratio of various metabolites to lipid content was compared between the normal and cirrhosis group. The main characteristic change in proton MR spectra in cases of liver cirrhosis compared with normal liver was decreased relative intensity of lipid peak. Mean and standard deviation of ratio of glutamate + glutamine/lipids, phosphomonoesters /lipids, glycogen + glucose /lipid calculated from the area of their peaks of normal and cirrhotic liver were 0.0204 ±0.0067 and 0.0693 ±0.0371 (p less than 0.05), 0.0146 ± 0.0090 and 0.0881 ±0.0276 (p less than 0.05), 0.0403 ± 0.0267 and 0.2325 ± 0.1071 (p less than 0.05), respectively The other characteristic feature of proton MR spectra of liver cirrhosis was the peak

  20. Rapid identification of single microbes by various Raman spectroscopic techniques

    Science.gov (United States)

    Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen

    2006-02-01

    A fast and unambiguous identification of microorganisms is necessary not only for medical purposes but also in technical processes such as the production of pharmaceuticals. Conventional microbiological identification methods are based on the morphology and the ability of microbes to grow under different conditions on various cultivation media depending on their biochemical properties. These methods require pure cultures which need cultivation of at least 6 h but normally much longer. Recently also additional methods to identify bacteria are established e.g. mass spectroscopy, polymerase chain reaction (PCR), flow cytometry or fluorescence spectroscopy. Alternative approaches for the identification of microorganisms are vibrational spectroscopic techniques. With Raman spectroscopy a spectroscopic fingerprint of the microorganisms can be achieved. Using UV-resonance Raman spectroscopy (UVRR) macromolecules like DNA/RNA and proteins are resonantly enhanced. With an excitation wavelength of e.g. 244 nm it is possible to determine the ratio of guanine/cytosine to all DNA bases which allows a genotypic identification of microorganisms. The application of UVRR requires a large amount of microorganisms (> 10 6 cells) e.g. at least a micro colony. For the analysis of single cells micro-Raman spectroscopy with an excitation wavelength of 532 nm can be used. Here, the obtained information is from all type of molecules inside the cells which lead to a chemotaxonomic identification. In this contribution we show how wavelength dependent Raman spectroscopy yields significant molecular information applicable for the identification of microorganisms on a single cell level.

  1. Monitoring the healing of combat wounds using Raman spectroscopic mapping.

    Science.gov (United States)

    Crane, Nicole J; Brown, Trevor S; Evans, Korboi N; Hawksworth, Jason S; Hussey, Sean; Tadaki, Doug K; Elster, Eric A

    2010-01-01

    Soldiers wounded in modern warfare present with extensive and complicated acute wounds, confounded by an overwhelming inflammatory response. The pathophysiology of acute wounds is unknown and timing of wound closure remains subjective. Collagen gene expression profiles are presented for 24 patients. Impaired healing wounds showed a twofold decrease in the up-regulation of COL1A1 and COL3A1 genes in the beginning of the wound healing process, compared with normal healing wounds. By the final debridement, however, collagen gene expression profiles for normal and impaired healing wounds were similar for COL1A1 and COL3A1. In addition, Raman spectroscopic maps were collected of biopsy tissue sections, from the first and last debridements of 10 wounds collected from nine patients. Tissue components obtained for the debridement biopsies were compared to elucidate whether or not a wound healed normally. Raman spectroscopy showed a loss of collagen in five patients, indicated by a negative percent difference in the 1,665/1,445 cm(-1) band area ratios. Four healed patients showed an increased or unchanged collagen content. Here, we demonstrate the potential of Raman spectroscopic analysis of wound biopsies for classification of wounds as normal or impaired healing. Raman spectroscopy has the potential to noninvasively monitor collagen deposition in the wound bed, during surgical wound debridements, to help determine the optimal time for wound closure.

  2. Spectroscopic studies of carbon impurities in PISCES-A

    International Nuclear Information System (INIS)

    Ra, Y.; Hirooka, Y.; Leung, W.K.; Conn, R.W.; Pospieszczyk, A.

    1989-08-01

    The graphite used for the limiter of the tokamak reactor produces carbon-containing molecular impurities as a result of the interactions with the edge plasma. The behavior of these molecular impurities has been studied using emission spectroscopy. The present study includes: finding molecular bands and atomic lines in the visible spectral range which can be used for the study of the molecular impurities, studying the breakup processes of the molecular impurities on their way from the source into the plasma, developing a spectroscopic diagnostic method for the absolute measurement of the molecular impurity flux resulting from graphite erosion. For these studies, carbon-containing molecules such as CH 4 , C 2 H 2 , C 2 H 4 , and CO 2 were injected into the tokamak-boundary,like plasma generated by PISCES-A. The spectrograms of these gases were taken. Many useful bands and lines were determined from the spectrograms. The breakup processes of these gases were studied by observing the spatial profiles of the emission of the molecules and their radicals for different plasma conditions. For the absolute measurement of the eroded molecular impurity flux, the photon efficiency of the lines and bands were found by measuring the absolute number of the emitted photons and injected gas molecules. The chemical sputtering yield of graphite by hydrogen plasma was spectroscopically measured using the previously obtained photon efficiencies. It showed good agreement with results obtained by weight loss measurements. 16 refs., 7 figs., 1 tab

  3. Spectroscopic study on the stability of morin in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Bark, Ki Min [Dept. of Chemical Education and Research Institute of Life Science, Gyeongsang National University, Chinju (Korea, Republic of); Im, Seo Eun; Seo, Jung Ja; Park, Ok Hyun; Park, Hyoung Ryun [Dept. of Chemistry, Chonnam National University, Gwangju (Korea, Republic of); Park, Chul Ho [Dept. of Cosmetic Science, Nambu University, Gwangju (Korea, Republic of)

    2015-02-15

    Morin (3,2,4,5,7-pentahydroxyflavone) is a flavonol conjugated to a resorcinol moiety at the C-2 position, different from many other flavonoids. The UV–vis spectrum of morin in neat water reveals two major absorption bands with maxima at 265 and 387 nm. The substance is stable in acidic solution and neat water. However, its absorption maximum at 387 nm continuously shifts to longer wavelengths and new peaks appeared at wavelengths of 312 nm with increasing pH of the solution. The shape of the absorption spectrum of morin depends on the storage time at a given pH, indicating the occurrence of other successive chemical reactions. The fluorescence spectroscopic results also prove that new conjugated double bonds are formed in the deaerated basic solution at the initial state and decompose with time. This behavior indicates that morin is very unstable, and therefore its decomposition occurs by a sequence of multistep reactions in basic solution. Probable reaction pathways for the reaction are suggested based on the spectroscopic results.

  4. Spectroscopic identification of individual fluorophores using photoluminescence excitation spectra.

    Science.gov (United States)

    Czerski, J; Colomb, W; Cannataro, F; Sarkar, S K

    2018-01-25

    The identity of a fluorophore can be ambiguous if other fluorophores or nonspecific fluorescent impurities have overlapping emission spectra. The presence of overlapping spectra makes it difficult to differentiate fluorescent species using discrete detection channels and unmixing of spectra. The unique absorption and emission signatures of fluorophores provide an opportunity for spectroscopic identification. However, absorption spectroscopy may be affected by scattering, whereas fluorescence emission spectroscopy suffers from signal loss by gratings or other dispersive optics. Photoluminescence excitation spectra, where excitation is varied and emission is detected at a fixed wavelength, allows hyperspectral imaging with a single emission filter for high signal-to-background ratio without any moving optics on the emission side. We report a high throughput method for measuring the photoluminescence excitation spectra of individual fluorophores using a tunable supercontinuum laser and prism-type total internal reflection fluorescence microscope. We used the system to measure and sort the photoluminescence excitation spectra of individual Alexa dyes, fluorescent nanodiamonds (FNDs), and fluorescent polystyrene beads. We used a Gaussian mixture model with maximum likelihood estimation to objectively separate the spectra. Finally, we spectroscopically identified different species of fluorescent nanodiamonds with overlapping spectra and characterized the heterogeneity of fluorescent nanodiamonds of varying size. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  5. Systems budgets architecture and development for the Maunakea Spectroscopic Explorer

    Science.gov (United States)

    Mignot, Shan; Flagey, Nicolas; Szeto, Kei; Murowinski, Rick; McConnachie, Alan

    2016-08-01

    The Maunakea Spectroscopic Explorer (MSE) project is an enterprise to upgrade the existing Canada-France- Hawaii observatory into a spectroscopic facility based on a 10 meter-class telescope. As such, the project relies on engineering requirements not limited only to its instruments (the low, medium and high resolution spectrographs) but for the whole observatory. The science requirements, the operations concept, the project management and the applicable regulations are the basis from which these requirements are initially derived, yet they do not form hierarchies as each may serve several purposes, that is, pertain to several budgets. Completeness and consistency are hence the main systems engineering challenges for such a large project as MSE. Special attention is devoted to ensuring the traceability of requirements via parametric models, derivation documents, simulations, and finally maintaining KAOS diagrams and a database under IBM Rational DOORS linking them together. This paper will present the architecture of the main budgets under development and the associated processes, expand to highlight those that are interrelated and how the system, as a whole, is then optimized by modelling and analysis of the pertinent system parameters.

  6. Vibrational spectroscopic analysis of breast calcifications and surrounding tissue

    Science.gov (United States)

    Baker, Rebecca N.; Smith, Jennifer; Rogers, Keith D.; Stone, Nicholas

    2006-02-01

    Breast calcifications can be found in both benign and malignant lesions and the composition of these calcifications can indicate the possible disease state. Calcium oxalate dihydrate (COD) is found to be associated with benign lesions, however calcium hydroxyapatite (HAP) is found mainly in malignant tissue. As current practices such as mammography and histopathology examine the morphology of the specimen, they can not reliably distinguish between the two types of calcification, which frequently are the only features that indicate the presence of a cancerous lesion. Therefore this information can be used to make a simplistic diagnostic decision, if the biochemistry of the calcifications can be probed. Studies have been performed utilising the synchrotron mid-IR beamline at Daresbury (UK) to probe the local tissue biochemistry around breast calcifications. Raman and FTIR spectroscopic analysis of the same specimen have also been performed and spectral maps have been collected of areas in and around calcifications. Principal component analysis was used to identify the major differences in the spectra across each map. FTIR and Raman spectroscopic techniques provide complementary biochemical information and demonstrate great potential for determining biochemical changes in calcified breast tissue. Further studies will be carried out using these techniques to investigate the formation mechanisms and effects of hydroxyapatite on breast tissue and to correlate the type of hydroxyapatite present to the tumour grade.

  7. Three-dimensional spherical analyses of cosmological spectroscopic surveys

    Science.gov (United States)

    Nicola, Andrina; Refregier, Alexandre; Amara, Adam; Paranjape, Aseem

    2014-09-01

    Spectroscopic redshift surveys offer great prospects for constraining the dark sector in cosmology. Future surveys will however be both deep and wide and will thus require an analysis in three-dimensional spherical geometry. We review and compare several methods which have been proposed in the literature for this purpose, focusing in particular on implementations of the spherical harmonic tomography (SHT) power spectrum Clij and the spherical Fourier Bessel (SFB) power spectrum Cl(k ,k'). Using a Fisher analysis, we compare the forecasted constraints on cosmological parameters using these statistics. These constraints typically rely on approximations such as the Limber approximation and make specific choices in the numerical implementation of each statistic. Using a series of toy models, we explore the applicability of these approximations and study the sensitivity of the SHT and SFB statistics to the details of their implementation. In particular, we show that overlapping redshift bins may improve cosmological constraints using the SHT statistic when the number of bins is small, and that the SFB constraints are quite robust to changes in the assumed distance-redshift relation. We also find that the SHT can be tailored to be more sensitive to modes at redshifts close to the survey boundary, while the SFB appears better suited to capture information beyond the smooth shape of the power spectrum. In this context, we discuss the pros and cons of the different techniques and their impact on the design and analysis of future wide field spectroscopic surveys.

  8. Roundtable discussion of nuclear spectroscopic quantities - Their determination and use

    International Nuclear Information System (INIS)

    Wood, J.L.

    1986-01-01

    The tools now available for nuclear spectroscopy permit studies of extraordinary breadth and detail. Capabilities generally lie considerably beyond the existing data base for any nucleus. When extended mass regions are considered, one finds that there are essentially no regions studied with the full spectroscopic potential at hand. The main reason for this is that such undertakings place heavy demands on manpower. They have reached a point in the study of low-energy nuclear structure where it is necessary to be highly selective in the problems chose for study. To ensure that the best problems are selected, strong interaction between theory and experiment is needed. Experimentalists need to be aware of the kind of structure problems that can be posed. Theoreticians need to be aware of the potential for generating new spectroscopic information with the available state-of-the-art techniques. With this in mind, the status of the topics covered in this symposium will be discussed with an eye on where the experiments and theoretical developments need to be directed in near future studies

  9. Characterization by spectroscopic Ellipsometry, the physical properties of silver nanoparticles.

    Science.gov (United States)

    Coanga, Jean-Maurice

    2013-04-01

    Physicists are able to change their minds through their experiments. I think it is time to go kick the curse and go further in research if we want a human future. I work in the Nano-Optics and Plasmonics research. I defined with ellipsomètrie the structure of new type of Nano particles of silver. It's same be act quickly to replace the old dirty leaded electronic-connexion chip and by the other hand to find a new way for the heath care of cancer disease by nanoparticles the next killers of bad cells. Silver nanoparticle layers are obtained by Spark Plasma Sintering are investigated as an alternative to lead alloy based material for solder joint in power mechatronics modules. These layers are characterized by mean of conventional techniques that is the dilatometry technique, the resistivity measurement through the van der Pauw method, and the flash laser technique. Furthermore, the nanoparticles of silver layer are deeply studied by UV-Visible spectroscopic ellipsometry. Spectroscopic angles parameters are determined in function of temperature and dielectric constants are deduced and analyzed through an optical model which takes into account a Drude and a Lorentz component within the Bruggeman effective medium approximation (EMA). The relaxation times and the electrical conductivity are plot in function of temperature. The obtained electrical conductivity give significant result in good agreement to those reported by four points electrical measurement method.

  10. Rotatable broadband retarders for far infrared spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Kang, T.D.; Carr, G.; Zhou, T.; Kotelyanskii, M.; Sirenko, A.A.

    2010-12-09

    Rotatable retarders have been developed for applications in spectroscopic, full Mueller Matrix ellipsometry in the far-IR spectral range. Several materials, such as silicon, KRS-5, and a commercial polymer plastic (TOPAS) have been utilized to achieve a fully adjustable retardation between 0{sup o} and 90{sup o}. Experimental characteristics of the rotatable retarders that utilize three- and four-bounce designs are compared with calculations. We discuss the effect of light focusing on the performance of these rotatable retarders. Broadband optical retarders are required for spectroscopic ellipsometry in its full Mueller matrix (MM) realization. Performance of the MM ellipsometer depends on the capability to produce substantially linearly-independent Stokes vectors for the light incident onto the sample. As has been shown, the errors in the measuredMMof the sample are proportional to the condition number of the 4 x 4 matrix composed of the Stokes vectors of four polarization states incident at the sample. It can be proven that it is impossible to cover the Poincare sphere with linearly-independent Stokes vectors by only changing the linear polarization at the input surface of a stationary retarder. As we will illustrate further in this paper, total coverage of the Poincare sphere is possible by rotating a tandem of a linear polarizer and a retarder with a retardation of 90{sup o}. It is this goal that we are trying to achieve in the retarder designs described in this paper.

  11. Spectroscopic diagnostics of plasma during laser processing of aluminium

    Science.gov (United States)

    Lober, R.; Mazumder, J.

    2007-10-01

    The role of the plasma in laser-metal interaction is of considerable interest due to its influence in the energy transfer mechanism in industrial laser materials processing. A 10 kW CO2 laser was used to study its interaction with aluminium under an argon environment. The objective was to determine the absorption and refraction of the laser beam through the plasma during the processing of aluminium. Laser processing of aluminium is becoming an important topic for many industries, including the automobile industry. The spectroscopic relative line to continuum method was used to determine the electron temperature distribution within the plasma by investigating the 4158 Å Ar I line emission and the continuum adjacent to it. The plasmas are induced in 1.0 atm pure Ar environment over a translating Al target, using f/7 and 10 kW CO2 laser. Spectroscopic data indicated that the plasma composition and behaviour were Ar-dominated. Experimental results indicated the plasma core temperature to be 14 000-15 300 K over the incident range of laser powers investigated from 5 to 7 kW. It was found that 7.5-29% of the incident laser power was absorbed by the plasma. Cross-section analysis of the melt pools from the Al samples revealed the absence of any key-hole formation and confirmed that the energy transfer mechanism in the targets was conduction dominated for the reported range of experimental data.

  12. Standardization and the European Standards Organisations

    Directory of Open Access Journals (Sweden)

    Marta Orviska

    2014-01-01

    Full Text Available Standardization is a relatively neglected aspect of the EU regulatory process and yet it is fundamental to that process and arguably has recently been the key vehicle in making the single market an economic reality. Yet the key standardization bodies in the EU, the ESOs, are scarcely known to the public and seldom discussed in the literature. In this article we redress this imbalance, arguing that standardization and integration are closely related concepts. We also argue that the ESOs have developed a degree of autonomy in expanding the boundaries of standardization and even in developing their own links with the rest of the world. Recent proposals put forward by the European Commission can be seen as an attempt to reduce that autonomy. These proposals emphasize the speed of, and stakeholder involvement in, standards production, which we further suggest are somewhat conflicting aims.

  13. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  14. The Gaia Red Clump as standard candle

    Science.gov (United States)

    Ruiz-Dern, L.; Babusiaux, C.; Danielski, C.; Arenou, F.; Turon, C.; Lallement, R.

    2017-12-01

    Gaia has already provided new high precision parallaxes for two million objects, allowing to recalibrate standard candles. Red Clump stars are known to be good standard candles because of their small dependency of their luminosity on their stellar composition, colour and age. We developed methods to derive some of the main physical parameters to characterise the Red Clump as standard candle. We provide fully empirical calibrations by using visual to infrared photometry, the most up-to-date 3D extinction map, and spectroscopic atmosphere parameters. We derived new calibrations for 16 Colour-(\\gk) and Effective Temperature-(\\gk) relations and a new calibration of the RC absolute magnitude on the Gaia G and 2MASS \\ks bands. These calibrations are used afterwards to estimate the G-band interstellar extinction coefficient k_{G}. By combining of all these relations we implemented a method to determine effective temperatures and interstellar extinctions (A_0), which we will use in particular to derive asteroseismic parameters which can be directly compared with Gaia's results.

  15. Spectroscopic quantum imaging using pixel-level ADCS in Semiconductor-based Hybrid pixel detectors

    NARCIS (Netherlands)

    San Segundo Bello, D.

    2009-01-01

    This thesis describes the design of a microelectronic system that can be used to build a spectroscopic imaging system, in particular a spectroscopic quantum imaging using pixel-level ADCs in semiconductor-based hybrid pixel detectors. In such a system the signal generated in the sensor by a photon

  16. ePESSTO spectroscopic classification of the candidate TDE XMMSL2 J140446.9-251135

    Science.gov (United States)

    Taubenberger, S.; Floers, A.; Vogl, C.; Benetti, S.; Pastorello, A.; Cappellaro, E.; Anderson, J.; Gromadzki, M.; Onori, F.; Kostrzewa-Rutkowska, Z.; Jonker, P.; Leloudas, G.; Inserra, C.; Kankare, E.; Maguire, K.; Smartt, S. J.; Yaron, O.; Young, D.

    2018-03-01

    ePESSTO, the extended Public ESO Spectroscopic Survey for Transient Objects (see Smartt et al. 2015, A & A, 579, 40; http://www.pessto.org ), reports the following spectroscopic observation of the new X-ray source XMMSL2 J140446.9-251135 in the galaxy 2MASX 14044671-2511433 (ATel #11394).

  17. Particle in a Disk: A Spectroscopic and Computational Laboratory Exercise Studying the Polycyclic Aromatic Hydrocarbon Corannulene

    Science.gov (United States)

    Frey, E. Ramsey; Sygula, Andrzej; Hammer, Nathan I.

    2014-01-01

    This laboratory exercise introduces undergraduate chemistry majors to the spectroscopic and theoretical study of the polycyclic aromatic hydrocarbon (PAH), corannulene. Students explore the spectroscopic properties of corannulene using UV-vis and Raman vibrational spectroscopies. They compare their experimental results to simulated vibrational…

  18. Gas Chromatography-Mass Spectroscopic (GC-MS) Analysis of n ...

    African Journals Online (AJOL)

    tuber-regium (synonym Pleurotus tuber regium) using gas chromatography-mass spectroscopic (GC-. MS) techniques. Methods: The n-hexane extract of the sclerotia ... Soxhlet extraction and analysed using gas chromatography-mass spectroscopic (MS) techniques. ..... Phytochemical composition of Pleurotus tuber regium.

  19. Spectroscopic, structural, thermal and antimicrobial studies of 4,6-bis

    African Journals Online (AJOL)

    The isolated complexes were characterized by elemental analysis, magnetic properties, conductance measurements, mass, IR, UV-Vis and 1H NMR spectroscopic methods and thermal analyses. The thermogravimetric and infrared spectroscopic data confirmed the presence of water in the composition of the complexes ...

  20. Collaboration Between Multistakeholder Standards

    DEFF Research Database (Denmark)

    Rasche, Andreas; Maclean, Camilla

    Public interest in corporate social responsibility (CSR) has resulted in a wide variety of multistakeholder CSR standards in which companies can choose to participate. While such standards reflect collaborative governance arrangements between public and private actors, the market for corporate...... responsibility is unlikely to support a great variety of partly competing and overlapping standards. Increased collaboration between these standards would enhance both their impact and their adoption by firms. This report examines the nature, benefits, and shortcomings of existing multistakeholder standards...

  1. Spectroscopic analysis and molecular docking of imidazole derivatives and investigation of its reactive properties by DFT and molecular dynamics simulations

    Science.gov (United States)

    Thomas, Renjith; Hossain, Mossaraf; Mary, Y. Sheena; Resmi, K. S.; Armaković, Stevan; Armaković, Sanja J.; Nanda, Ashis Kumar; Ranjan, Vivek Kumar; Vijayakumar, G.; Van Alsenoy, C.

    2018-04-01

    Solvent-free synthesis pathway for obtaining two imidazole derivatives (2-chloro-1-(4-methoxyphenyl)-4,5-dimethyl-1H-imidazole (CLMPDI) and 1-(4-bromophenyl)-2-chloro-4,5-dimethyl-1H-imidazole (BPCLDI) has been reported in this work, followed by detailed experimental and computational spectroscopic characterization and reactivity study. Spectroscopic methods encompassed IR, FT-Raman and NMR techniques, with the mutual comparison of experimentally and computationally obtained results at DFT/B3LYP level of theory. Reactivity study based on DFT calculations encompassed molecular orbitals analysis, followed by calculations of molecular electrostatic potential (MEP) and average local ionization energy (ALIE) values, Fukui functions and bond dissociation energies (BDE). Additionally, the stability of title molecules in water has been investigated via molecular dynamics (MD) simulations, while interactivity with aspulvinonedimethylallyl transferase protein has been evaluated by molecular docking procedure. CLMPDI compound showed antimicrobial activity against all four bacterial strain in both gram positive and gram negative bacteria while, BPCLDI showed only in gram positive bacteria, Staphylococcus Aureus (MTCC1144). The first order hyperpolarizability of CLMPDI and BPCLDI are 20.15 and 6.10 times that of the standard NLO material urea.

  2. Spectroscopic sensors for in-line bioprocess monitoring in research and pharmaceutical industrial application.

    Science.gov (United States)

    Claßen, Jens; Aupert, Florian; Reardon, Kenneth F; Solle, Dörte; Scheper, Thomas

    2017-01-01

    The use of spectroscopic sensors for bioprocess monitoring is a powerful tool within the process analytical technology (PAT) initiative of the US Food and Drug Administration. Spectroscopic sensors enable the simultaneous real-time bioprocess monitoring of various critical process parameters including biological, chemical, and physical variables during the entire biotechnological production process. This potential can be realized through the combination of spectroscopic measurements (UV/Vis spectroscopy, IR spectroscopy, fluorescence spectroscopy, and Raman spectroscopy) with multivariate data analysis to obtain relevant process information out of an enormous amount of data. This review summarizes the newest results from science and industry after the establishment of the PAT initiative and gives a critical overview of the most common in-line spectroscopic techniques. Examples are provided of the wide range of possible applications in upstream processing and downstream processing of spectroscopic sensors for real-time monitoring to optimize productivity and ensure product quality in the pharmaceutical industry.

  3. Optical and laser spectroscopic diagnostics for energy applications

    Science.gov (United States)

    Tripathi, Markandey Mani

    The continuing need for greater energy security and energy independence has motivated researchers to develop new energy technologies for better energy resource management and efficient energy usage. The focus of this dissertation is the development of optical (spectroscopic) sensing methodologies for various fuels, and energy applications. A fiber-optic NIR sensing methodology was developed for predicting water content in bio-oil. The feasibility of using the designed near infrared (NIR) system for estimating water content in bio-oil was tested by applying multivariate analysis to NIR spectral data. The calibration results demonstrated that the spectral information can successfully predict the bio-oil water content (from 16% to 36%). The effect of ultraviolet (UV) light on the chemical stability of bio-oil was studied by employing laser-induced fluorescence (LIF) spectroscopy. To simulate the UV light exposure, a laser in the UV region (325 nm) was employed for bio-oil excitation. The LIF, as a signature of chemical change, was recorded from bio-oil. From this study, it was concluded that phenols present in the bio-oil show chemical instability, when exposed to UV light. A laser-induced breakdown spectroscopy (LIBS)-based optical sensor was designed, developed, and tested for detection of four important trace impurities in rocket fuel (hydrogen). The sensor can simultaneously measure the concentrations of nitrogen, argon, oxygen, and helium in hydrogen from storage tanks and supply lines. The sensor had estimated lower detection limits of 80 ppm for nitrogen, 97 ppm for argon, 10 ppm for oxygen, and 25 ppm for helium. A chemiluminescence-based spectroscopic diagnostics were performed to measure equivalence ratios in methane-air premixed flames. A partial least-squares regression (PLS-R)-based multivariate sensing methodology was investigated. It was found that the equivalence ratios predicted with the PLS-R-based multivariate calibration model matched with the

  4. Standards, Standards, Standards: The Unintended Consequences of Widening Participation?

    Science.gov (United States)

    Stuart, Mary

    2002-01-01

    Debate over widening access to higher education is narrowing to a focus on preservation of standards. Examination of the discourses of school policy, classroom environment, and peer culture shows how these competing cultures can work against efforts to increase participation. (Contains 17 references.) (SK)

  5. Spectroscopic diagnosis of foam z-pinch plasmas on SATURN

    International Nuclear Information System (INIS)

    Nash, T.J.; Derzon, M.S.; Allshouse, G.; Deeney, C.; Jobe, D.; McGurn, J.; MacFarlane, J.J.; Wang, P.

    1996-01-01

    Solid and annular silicon aerogel and agar foams were shot on the accelerator SATURN to study plasma initiation, acceleration, and stagnation. SATURN delivers 7 MA with a 50 nsec rise time to these foam loads. We fielded several spectroscopic diagnostics to measure plasma parameters throughout the z-pinch discharge. A spatially resolved single frame time-gated EUV spectrometer measured the extent of plasma ablation off the surface foam. A time integrated crystal spectrometer showed that characteristic K shell radiation of silicon in the aerogel and of S and Na impurities in the agar were all attenuated when the foam loads were coated with a conductive layer of gold. The time resolved pinhole camera showed that in general the quality of the pinch implosions was poor but improved with increasing efforts to improve current continuity such as prepulse and conductive coatings

  6. Spectroscopic studies on the photochemical decarboxylation mechanisms of synthetic pyrethroids.

    Science.gov (United States)

    Suzuki, Yusuke; Ishizaka, Shoji; Kitamura, Noboru

    2012-12-01

    A novel radical trapping technique combined with a fluorescence spectroscopic analysis has been employed to investigate the radical intermediates produced by photodecarboxylation of four synthetic pyrethroids: fenvalerate (SMD), fenpropathrin (DTL), cyphenothrin (GKL), and cypermethrin (AGT). Under photoirradiation at >290 nm, all pyrethroids underwent direct photolysis via homolytic cleavage of the carbon-oxygen bonds in the ester groups. The consumed amount of a nitroxide free radical, as a trapping agent for the intermediate radical of a pyrethroid, was determined by ESR, which was the measure of the reaction yield of a photochemically generated α-cyano-3-phenoxybenzyl radical common to all pyrethroids. The reactivities of the pyrethroids studied was in the sequence of SMD > DTL > GKL > AGT. Furthermore, nanosecond transient absorption spectroscopy demonstrated that geminate recombination of the radical pair within a solvent cage is the main deactivation route of the photochemically generated α-cyano-3-phenoxybenzyl radical common for all pyrethroids studied.

  7. Nanostructure characterization of high k materials by spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Pereira, L.; Aguas, H.; Fortunato, E.; Martins, R.

    2006-01-01

    In this work, the optical and structural properties of high k materials such as tantalum oxide and titanium oxide were studied by spectroscopic ellipsometry, where a Tauc-Lorentz dispersion model based in one (amorphous films) or two oscillators (microcrystalline films) was used. The samples were deposited at room temperature by radio frequency magnetron sputtering and then annealed at temperatures from 100 to 500 deg. C. Concerning the tantalum oxide films, the increase of the annealing temperature, up to 500 deg. C does not change the amorphous nature of the films, increasing, however, their density. The same does not happen with the titanium oxide films that are microcrystalline, even when deposited at room temperature. Data concerning the use of a four-layer model based on one and two Tauc-Lorentz dispersions is also discussed, emphasizing its use for the detection of an amorphous incubation layer, normally present on microcrystalline films grown by sputtering

  8. Spectroscopic and theoretical investigations of phenolic acids in white wines.

    Science.gov (United States)

    Martin, Coralie; Bruneel, Jean-Luc; Castet, Frédéric; Fritsch, Alain; Teissedre, Pierre-Louis; Jourdes, Michael; Guillaume, François

    2017-04-15

    Model solutions of white wines containing phenolic acids have been investigated by means of UV-vis, laser induced fluorescence and Raman spectroscopic techniques. In order to interpret the spectra, density functional theory calculations of phenolic acids have been performed. This work demonstrates that only hydroxynamic acids are in resonance with a laser excitation line with 325nm wavelength and are therefore at the origin of the strong enhancement of the Raman light scattering. Real white wines also display such resonance Raman scattering so that their content in hydroxycinnamic acids may be quite precisely determined. The analysis of the Raman spectrum of a real dry white wine reveals qualitatively the preponderance in its composition of p-coumaric and caftaric acids. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Spectroscopic X-ray imaging with photon counting pixel detectors

    CERN Document Server

    Tlustos, L

    2010-01-01

    Single particle counting hybrid pixel detectors simultaneously provide low noise, high granularity and high readout speed and make it possible to build detector systems offering high spatial resolution paired with good energy resolution. A limiting factor for the spectroscopic performance of such detector systems is charge sharing between neighbouring pixels in the sensor part of the detector. The signal spectrum at the collection electrodes of the readout electronics deviates significantly from the photonic spectrum when planar segmented sensor geometries are used. The Medipix3 implements a novel, distributed signal processing architecture linking neighbouring pixels and aims at eliminating the spectral distortion produced in the sensor by charge sharing and at reducing the impact of fluorescence photons generated in the sensor itself. Preliminary results from the very first Medipix3 readouts bump bonded to 300 pm Si sensor are presented. Material reconstruction is a possible future application of spectrosco...

  10. SPECTROSCOPIC CHARACTERIZATION AND DETECTION OF ETHYL MERCAPTAN IN ORION

    International Nuclear Information System (INIS)

    Kolesniková, L.; Alonso, J. L.; Daly, A. M.; Tercero, B.; Cernicharo, J.; Gordon, B. P.; Shipman, S. T.

    2014-01-01

    New laboratory data of ethyl mercaptan, CH 3 CH 2 SH, in the millimeter- and submillimeter-wave domains (up to 880 GHz) provided very precise values of the spectroscopic constants that allowed the detection of gauche-CH 3 CH 2 SH toward Orion KL. This identification is supported by 77 unblended or slightly blended lines plus no missing transitions in the range 80-280 GHz. A detection of methyl mercaptan, CH 3 SH, in the spectral survey of Orion KL is reported as well. Our column density results indicate that methyl mercaptan is ≅ 5 times more abundant than ethyl mercaptan in the hot core of Orion KL

  11. On spectroscopic factors of magic and semimagic nuclei

    International Nuclear Information System (INIS)

    Saperstein, E. E.; Gnezdilov, N. V.; Tolokonnikov, S. V.

    2014-01-01

    Single-particle spectroscopic factors (SF) of magic and semimagic nuclei are analyzed within the self-consistent theory of finite Fermi systems. The the in-volume energy dependence of the mass operator Σ is taken into account in addition to the energy dependence induced by the surface-phonon coupling effects which is commonly considered. It appears due to the effect of high-lying collective and non-collective particle-hole excitations and persists in nuclear matter. The self-consistent basis of the energy density functional method by Fayans et al. is used. Both the surface and in-volume contributions to the SFs turned out to be of comparable magnitude. Results for magic 208 Pb nucleus and semimagic lead isotopes are presented

  12. Spectroscopic investigation of degradation of rapseed oil methyl esters

    International Nuclear Information System (INIS)

    Kampars, V.

    2003-01-01

    Investigation of rapseed oil methyl esters by US VIS and FTIR spectroscopy during the heating at 80 deg C were carried out. The degradation begins immediately after beginning of experiment. The main process at first stage is destroying of carotenoids and oxidation of polyunsaturated fatty acids by forming conjugated polyenes. Between the formation of conjugated triens and destroying of carotenoids exist definite interconnection, but there isn't evidence for the protective activity of carotenoids. As follows from FTIR spectroscopy the increase of carbonyl compounds concentration begins immediately after the start of experiment and continues all the time. Despite to the complex character the peak at 220 nm is only one spectroscopic characteristic with a sharp alteration point and may be used for the fast and simple detection of storage stability of bio diesels. (authors)

  13. Spectroscopic study of photo and thermal destruction of riboflavin

    Science.gov (United States)

    Astanov, Salikh; Sharipov, Mirzo Z.; Fayzullaev, Askar R.; Kurtaliev, Eldar N.; Nizomov, Negmat

    2014-08-01

    Influence of temperature and light irradiation on the spectroscopic properties of aqueous solutions of riboflavin was studied using linear dichroism method, absorption and fluorescence spectroscopy. It was established that in a wide temperature range 290-423 K there is a decline of absorbance and fluorescence ability, which is explained by thermodestruction of riboflavin. It is shown that the proportion of molecules, which have undergone degradation, are in the range of 4-28%, and depends on the concentration and quantity of temperature effects. Introduction of hydrochloric and sulfuric acids, as well as different metal ions leads to an increase in the photostability of riboflavin solutions by 2-2.5 times. The observed phenomena are explained by the formation protonation form of riboflavin and a complex between the metal ions and oxygen atoms of the carbonyl group of riboflavin, respectively.

  14. Structural and spectroscopic studies of a commercial glassy carbon

    Science.gov (United States)

    Parker, Stewart F.; Imberti, Silvia; Callear, Samantha K.; Albers, Peter W.

    2013-12-01

    Glassy carbon is a form of carbon made by heating a phenolic resin to high temperature in an inert atmosphere. It has been suggested that it is composed of fullerene-like structures. The aim of the present work was to characterize the material using both structural (neutron diffraction and transmission electron microscopy) and spectroscopic (inelastic neutron scattering, Raman and X-ray photoelectron spectroscopies) methods. We find no evidence to support the suggestion of fullerene-like material being present to a significant extent, rather the model that emerges from all of the techniques is that the material is very like amorphous carbon, consisting of regions of small graphite-like basic structural units of partly stacked but mismatched structure with the edges terminated by hydrogen or hydroxyls. We do find evidence for the presence of a small quantity of water trapped in the network and suggest that this may account for batch-to-batch variation in properties that may occur.

  15. Noble metal ionic sites for catalytic hydrogen combustion: spectroscopic insights.

    Science.gov (United States)

    Deshpande, Parag A; Madras, Giridhar

    2011-01-14

    A catalytic hydrogen combustion reaction was carried out over noble metal catalysts substituted in ZrO(2) and TiO(2) in ionic form. The catalysts were synthesized by the solution combustion technique. The compounds showed high activity and CO tolerance for the reaction. The activity of Pd and Pt ion substituted TiO(2) was comparable and was higher than Pd and Pt ion substituted ZrO(2). The mechanisms of the reaction over the two supports were proposed by making use of the X-ray photoelectron spectroscopy and FT infrared spectroscopic observations. The reaction over ZrO(2) supported catalysts was proposed to take place by the utilization of the surface hydroxyl groups while the reaction over TiO(2) supported catalysts was hypothesized to be a hybrid mechanism utilizing surface hydroxyl groups and the lattice oxygen.

  16. Imaging spectroscopic analysis at the Advanced Light Source

    International Nuclear Information System (INIS)

    MacDowell, A. A.; Warwick, T.; Anders, S.; Lamble, G.M.; Martin, M.C.; McKinney, W.R.; Padmore, H.A.

    1999-01-01

    One of the major advances at the high brightness third generation synchrotrons is the dramatic improvement of imaging capability. There is a large multi-disciplinary effort underway at the ALS to develop imaging X-ray, UV and Infra-red spectroscopic analysis on a spatial scale from. a few microns to 10nm. These developments make use of light that varies in energy from 6meV to 15KeV. Imaging and spectroscopy are finding applications in surface science, bulk materials analysis, semiconductor structures, particulate contaminants, magnetic thin films, biology and environmental science. This article is an overview and status report from the developers of some of these techniques at the ALS. The following table lists all the currently available microscopes at the. ALS. This article will describe some of the microscopes and some of the early applications

  17. The DFBS Spectroscopic Database and the Armenian Virtual Observatory

    Directory of Open Access Journals (Sweden)

    Areg M Mickaelian

    2009-05-01

    Full Text Available The Digitized First Byurakan Survey (DFBS is the digitized version of the famous Markarian Survey. It is the largest low-dispersion spectroscopic survey of the sky, covering 17,000 square degrees at galactic latitudes |b|>15. DFBS provides images and extracted spectra for all objects present in the FBS plates. Programs were developed to compute astrometric solution, extract spectra, and apply wavelength and photometric calibration for objects. A DFBS database and catalog has been assembled containing data for nearly 20,000,000 objects. A classification scheme for the DFBS spectra is being developed. The Armenian Virtual Observatory is based on the DFBS database and other large-area surveys and catalogue data.

  18. ESR spectroscopic investigations of the radiation-grafting of fluoropolymers

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, G.; Roduner, E. [University of Stuttgart (Germany); Brack, H.P.; Scherer, G.G. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    ESR spectroscopic investigations have clarified the influence of several preparative parameters on the reaction rates and yields obtained in the radiation-grafting method used at PSI to prepare proton-conducting polymer membranes. At a given irradiation dose, a higher concentration of reactive radical sites was detected in ETFE films than in FEP films. This higher concentration explains the higher grafting levels and rates of the ETFE films found in our previous grafting experiments. Taken together, the in-situ ESR experiments and grafting experiments show that the rates of disappearance of radical species and grafting rates and final grafting levels depend strongly on the reaction temperature and the oxygen content of the system. Average grafted chain lengths were calculated to contain about 1,000 monomer units. (author) 2 figs., 4 refs.

  19. Simulating electric field interactions with polar molecules using spectroscopic databases.

    Science.gov (United States)

    Owens, Alec; Zak, Emil J; Chubb, Katy L; Yurchenko, Sergei N; Tennyson, Jonathan; Yachmenev, Andrey

    2017-03-24

    Ro-vibrational Stark-associated phenomena of small polyatomic molecules are modelled using extensive spectroscopic data generated as part of the ExoMol project. The external field Hamiltonian is built from the computed ro-vibrational line list of the molecule in question. The Hamiltonian we propose is general and suitable for any polar molecule in the presence of an electric field. By exploiting precomputed data, the often prohibitively expensive computations associated with high accuracy simulations of molecule-field interactions are avoided. Applications to strong terahertz field-induced ro-vibrational dynamics of PH 3 and NH 3 , and spontaneous emission data for optoelectrical Sisyphus cooling of H 2 CO and CH 3 Cl are discussed.

  20. Investigation on interaction of prulifloxacin with pepsin: A spectroscopic analysis

    Science.gov (United States)

    Huang, Yabei; Yan, Jie; Liu, Benzhi; Yu, Zhang; Gao, Xiaoyan; Tang, Yingcai; Zi, Yanqin

    2010-03-01

    The interaction between prulifloxacin, a kind of new oral taking antibiotic and pepsin, a kind of enzyme in the stomach has been investigated in vitro under a simulated physiological condition by different spectroscopic methods. The intrinsic fluorescence of pepsin was strongly quenched by prulifloxacin. This effect was rationalized in terms of a static quenching procedure. The binding parameters have been evaluated by fluorescence quenching methods. The negative value of Δ G0 reveals that the binding process is a spontaneous process. The binding distance R between donor (pepsin) and acceptor (prulifloxacin) was obtained according to the Förster's resonance energy transfer theory and found to be 0.95 nm. The results obtained herein will be of biological significance in pharmacology and clinical medicine.

  1. Ultrasonic and spectroscopic studies on photoactivation of euglena

    Science.gov (United States)

    Saito, Mitsunori; Morita, Shin

    2006-12-01

    We studied the effect of the irradiation wavelength on the activity of photosynthetic euglena. The ultrasonic manipulation technique was used for both the activity evaluation and the movement restriction in the spectral measurements. Euglenas that had been preserved in darkness became inactive, and accordingly most of them were trapped by the ultrasonic standing wave (0.8mW/mm2). However, when they were exposed to light of 500 or 700nm wavelength (0.13W/m2), they became active enough to escape from the trapping. By contrast, irradiation at 550, 600, or 650nm wavelength had no effect on their activity. Spectroscopic measurements, which used to be difficult for locomotive microorganisms, were conducted successfully by trapping euglena at a node of the ultrasonic standing wave. The absorption bands were observed at around 500 or 700nm, which corresponded to the irradiation wavelengths that activated euglena.

  2. Venus' spectroscopic phase variation - Implications of the Mariner 10 photographs

    Science.gov (United States)

    Chamberlain, J. W.

    1975-01-01

    The recent ultraviolet photographs of Venus by Mariner 10 have shown an irregular cloud structure. There is an apparent tendency for clearing along a wide equatorial band more or less centered on the subsolar point. This synoptic picture is in marked contrast to the uniform cloud cover conventionally used in model calculations of the variation with phase of CO2 absorption bands. To illustrate the consequences of subsolar weakening of CO2 absorption, a mathematically simple (but realistically naive) model is used. Two conclusions are reached: (1) efforts to distinguish between single- and double-layer models for the clouds from spectroscopic data alone are not merely ambiguous (as argued earlier by Chamberlain and Smith); with present data they are hopeless; (2) the decrease in the CO2 absorption close to full phase, as reported by Young et al., could result entirely from an equatorial darkening that is relatively inconsequential at the crescent phase and increasingly predominant for fuller phases.

  3. Fatty infiltration of the liver: evaluation by proton spectroscopic imaging

    International Nuclear Information System (INIS)

    Heiken, J.P.; Lee, J.K.; Dixon, W.T.

    1985-01-01

    The reliability of proton spectroscopic imaging in evaluating fatty infiltration of the liver was investigated in 35 subjects (12 healthy volunteers and 23 patients with fatty livers). With this modified spin-echo technique, fatty liver could be separated from normal liver both visually and quantitatively. On the opposed image, normal liver had an intermediate signal intensity, greater than that of muscle, whereas fatty liver had a lower signal intensity, equal to or less than that of muscle. In normal livers, the lipid signal fraction was less than 10%, while in fatty livers it was greater than 10% and usually exceeded 20%. With this technique, nonuniform fatty infiltration of the liver can be differentiated from hepatic metastases, and the technique may prove useful in the differentiation of some hepatic disorders

  4. Raman spectroscopic study of cyclohexane at pressures below 1000 MPa

    Science.gov (United States)

    Qiao, Erwei; Zheng, Haifei

    2017-10-01

    At present, the room temperature freezing pressure of cyclohexane is still uncertain, and the phase transition pressure of solid I - solid III is not reliable at ambient temperature. In this work, we have performed a Raman spectroscopic study of cyclohexane in a Moissanite anvil cell at pressures below 1000 MPa at 25 °C, and analyzed the characteristic of Raman brands νs(CH2), νas(CH2) and νb(Ring). Two phase transition pressures 80 MPa and 550 MPa were determined by a quartz pressure gauge, and they are the room temperature freezing pressure of cyclohexane and the phase transition pressure of solid I to solid III, respectively. Furthermore, from the phase diagram of cyclohexane, it is inferred that pressure plays an important role on the stability of cyclohexane as the main constituent of oil, and it can be beneficial to understanding the formation, migration and preservation of petroleum in subterranean rock strata.

  5. [Raman spectroscopic study on silicone fluid as pressure gauge].

    Science.gov (United States)

    Liu, Jin; Sun, Qiang

    2010-09-01

    Within a diamond-anvil cell, the in-situ Raman spectroscopic study of silicone fluid was operated at room temperature 298. 1 K and under pressures from 0.1 to 5140.2 MPa. The present study analyzed the correlation of the modes 2906 and 2967 cm(-1) with different pressures, indicating that their wavenumbers linearly increased with increasing pressure. Therefore, this provided the potential to consider the pressure medium silicone fluid as a pressure gauge. The result suggested that silicone fluid could be used as a reliable pressure gauge in high-pressure experiments using diamond-anvil cells with Raman spectrometer, and the correlations between pressure and (delta nu p)2906, (delta nu p)2967 are, p = -0.05[(delta nu p)2967]2 + 73.07 (delta nu p)2967 + 91.54 and p = 0.14 [(delta nu p)2906]2 + 81.9 (delta nu p)2906 + 92.01, respectively.

  6. Principles of Vibrational Spectroscopic Methods and their Application to Bioanalysis

    DEFF Research Database (Denmark)

    Moore, David S.; Jepsen, Peter Uhd; Volka, Karel

    2014-01-01

    blood, bone, brain tissue, and many other matrices. Although the application of FTIR directly to clinical studies and diagnosis has been very much debated, some promising results have been obtained for the in vivo monitoring of glucose, hemoglobin, urea, albumin, phosphocreatine, and nitric oxide...... excitation laser irradiance to avoid sample damage are also discussed. This chapter then reviews applications of Raman spectroscopy to bioanalysis. Areas discussed include pathology, cytopathology, single-cell analysis, in vivo and in vitro tissue characterization, chemical composition of cell components...... or nanostructures. Finally, terahertz spectroscopy has given many new possibilities for studies of low-frequency interactions between electromagnetic radiation and biomaterials. In contrast to spectroscopic techniques at shorter wavelengths, THz spectroscopy directly probes long-range dynamics in biomolecules (such...

  7. Analytical Raman spectroscopic discrimination between yellow pigments of the Renaissance

    Science.gov (United States)

    Edwards, Howell G. M.

    2011-10-01

    The Renaissance represented a major advance in painting techniques, subject matter, artistic style and the use of pigments and pigment mixtures. However, most pigments in general use were still mineral-based as most organic dyes were believed to be fugitive; the historical study of artists' palettes and recipes has assumed importance for the attribution of art works to the Renaissance period. Although the application of diagnostic elemental and molecular spectroscopic techniques play vital and complementary roles in the analysis of art works, elemental techniques alone cannot definitively provide the data needed for pigment identification. The advantages and limitations of Raman spectroscopy for the definitive diagnostic characterisation of yellow pigments that were in use during the Renaissance is demonstrated here in consideration of heavy metal oxides and sulphides; these data will be compared with those obtained from analyses of synthetic yellow pigments that were available during the eighteenth and nineteenth Centuries which could have been used in unrecorded restorations of Renaissance paintings.

  8. Raman spectroscopic study of "The Malatesta": a Renaissance painting?

    Science.gov (United States)

    Edwards, Howell G M; Vandenabeele, Peter; Benoy, Timothy J

    2015-02-25

    Raman spectroscopic analysis of the pigments on an Italian painting described as a "Full Length Portrait of a Gentleman", known also as the "Malatesta", and attributed to the Renaissance period has established that these are consistent with the historical research provenance undertaken earlier. Evidence is found for the early 19th Century addition of chrome yellow to highlighted yellow ochre areas in comparison with a similar painting executed in 1801 by Sir Thomas Lawrence of John Kemble in the role of Hamlet, Prince of Denmark. The Raman data are novel in that no analytical studies have previously been made on this painting and reinforces the procedure whereby scientific analyses are accompanied by parallel historical research. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Shell evolution and E2 collectivity: new spectroscopic information

    Science.gov (United States)

    Pietralla, N.; Kremer, C.; Lettmann, M.; Aslanidou, S.; Krugmann, A.; Lizarazo, C.; von Neumann-Cosel, P.; Werner, V.; Witt, W.

    2018-02-01

    We report here on the first evidence for shape coexistence caused by Type II Shell Evolution which is firmly based on the measurement of absolute E2 transition rates. The data have been obtained in high-resolution inelastic electron scattering spectroscopy of the nucleus 96 Zr at the Superconducting Darmstadt Linear electron Accelerator (S-DALINAC). The data are presented and discussed. The neutron sub-shell closure at neutron number N = 56 plays a crucial role for the occurence of shape coexistence in 96,98Zr. We have studied the structure of exotic neutron-rich isotopes near the N = 56 neutron sub-shell closure using γ-ray spectroscopy and radioactive beams. We also present and discuss spectroscopic data on 84,86,88Ge taken recently at RIBF, RIKEN. The new data suggest the hitherto unknown existence of a region of pronounced nuclear triaxiality in neutron-rich Ge isotopes.

  10. Spectroscopic properties of rare earths in optical materials

    CERN Document Server

    Parisi, Jürgen; Osgood, R; Warlimont, Hans; Liu, Guokui; Jacquier, Bernard

    2005-01-01

    Aimed at researchers and graduate students, this book provides up-to-date information for understanding electronic interactions that impact the optical properties of rare earth ions in solids. Its goal is to establish a connection between fundamental principles and the materials properties of rare-earth activated luminescent and laser optical materials. The theoretical survey and introduction to spectroscopic properties include electronic energy level structure, intensities of optical transitions, ion-phonon interactions, line broadening, and energy transfer and up-conversion. An important aspect of the book lies in its deep and detailed discussions on materials properties and the potential of new applications such as optical storage, information processing, nanophotonics, and molecular probes that have been identified in recent experimental studies. This volume will be a valuable reference book on advanced topics of rare earth spectroscopy and materials science.

  11. Spectroscopic Analysis of Today's Compact Fluorescent Light Bulbs

    Science.gov (United States)

    Pluhar, Edward

    2012-03-01

    In today's consumer market, there are many different light bulbs that claim to produce `natural' light. In my research, I both quantitatively and qualitatively analyzed this claim. First, utilizing a spectroscope, I compared the spectra emitted by different brands and types of compact fluorescent light (CFL) bulbs to the spectra emitted by the Sun. Once the bulbs were quantitatively analyzed, I proceeded to qualitatively analyze them by exposing subjects to the different bulbs. The subjects were asked to rate the quality of color in different pictures illuminated by each type of CFL. From these tests, I was able to determine the ``best'' CFL bulbs, and conclude whether the health risks associated with CFL bulbs outweigh the cost savings, longevity of the bulbs, and/or quality of light benefits.

  12. Spectroscopic Investigations with Dual Neutron-Gamma Scintillators

    Science.gov (United States)

    Chowdhury, P.; Brown, T.; Doucet, E.; Lister, C. J.; Morse, C.; Rogers, A. M.; Wilson, G. L.; Devlin, M.; Fotiades, N.; Gomez, J. A.; Mosby, S.

    2017-09-01

    The spectroscopic capabilities of 7Li-enriched Cs27LiYCl6 (C7LYC) dual neutron-gamma scintillators are being tested in diverse application arenas to exploit the excellent pulse-shape discrimination together with the unprecedented pulse height resolution ( 10%) for fast neutrons in the performed. A key goal is to evaluate whether the low intrinsic efficiency of C7LYC for fast neutrons compared to traditional neutron detectors, such as liquid scintillators, can be effectively offset by the gain in solid angle obtained by positioning the detectors much closer to the target, since the typical long time-of-flight arms for energy resolution are not necessary. Supported by the NNSA Stewardship Science Academic Alliance Program under Grant DE-NA0002932.

  13. Amino Acid and Peptide Immobilization on Oxidized Nanocellulose: Spectroscopic Characterization

    Science.gov (United States)

    Barazzouk, Saïd; Daneault, Claude

    2012-01-01

    In this work, oxidized nanocellulose (ONC) was synthesized and chemically coupled with amino acids and peptides using a two step coupling method at room temperature. First, ONC was activated by N-ethyl-N’-(3-dimethylaminopropyl) carbodiimide hydrochloride, forming a stable active ester in the presence of N-hydroxysuccinimide. Second, the active ester was reacted with the amino group of the amino acid or peptide, forming an amide bond between ONC and the grafted molecule. Using this method, the intermolecular interaction of amino acids and peptides was avoided and uniform coupling of these molecules on ONC was achieved. The coupling reaction was very fast in mild conditions and without alteration of the polysaccharide. The coupling products (ONC-amino acids and ONC-peptides) were characterized by transmission electron microscopy and by the absorption, emission, Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS) spectroscopic techniques. PMID:28348303

  14. Amino Acid and Peptide Immobilization on Oxidized Nanocellulose: Spectroscopic Characterization

    Directory of Open Access Journals (Sweden)

    Claude Daneault

    2012-06-01

    Full Text Available In this work, oxidized nanocellulose (ONC was synthesized and chemically coupled with amino acids and peptides using a two step coupling method at room temperature. First, ONC was activated by N-ethyl-N’-(3-dimethylaminopropyl carbodiimide hydrochloride, forming a stable active ester in the presence of N-hydroxysuccinimide. Second, the active ester was reacted with the amino group of the amino acid or peptide, forming an amide bond between ONC and the grafted molecule. Using this method, the intermolecular interaction of amino acids and peptides was avoided and uniform coupling of these molecules on ONC was achieved. The coupling reaction was very fast in mild conditions and without alteration of the polysaccharide. The coupling products (ONC-amino acids and ONC-peptides were characterized by transmission electron microscopy and by the absorption, emission, Fourier transform infrared spectroscopy (FTIR and X-ray photoelectron spectroscopy (XPS spectroscopic techniques.

  15. Vibrational spectroscopic methods for cytology and cellular research.

    Science.gov (United States)

    Clemens, Graeme; Hands, James R; Dorling, Konrad M; Baker, Matthew J

    2014-09-21

    The use of vibrational spectroscopy, FTIR and Raman, for cytology and cellular research has the potential to revolutionise the approach to cellular analysis. Vibrational spectroscopy is non-destructive, simple to operate and provides direct information. Importantly it does not require expensive exogenous labels that may affect the chemistry of the cell under analysis. In addition, the advent of spectroscopic microscopes provides the ability to image cells and acquire spectra with a subcellular resolution. This introductory review focuses on recent developments within this fast paced field and highlights potential for the future use of FTIR and Raman spectroscopy. We particularly focus on the development of live cell research and the new technologies and methodologies that have enabled this.

  16. Spectroscopic detection of abnormality in chicken liver as an inspection tool

    Science.gov (United States)

    Dey, Bhabani P.; Chan, Diane E.; Chen, Yud-Ren; Gwozdz, Frank B.

    2004-03-01

    Successful differentiation of normal chicken livers from septicemic chicken livers was demonstrated using visible/near-infrared (Vis/NIR) spectral data subjected to principal component analysis and then fed into a feedforward back-propagation neural network. The study used 300 fresh chicken livers, 150 collected from normal chicken carcasses and 150 collected from chicken carcasses diagnosed with the septicemica/toxemia (septox) condition as defined for condemnation under U.S. Department of Agriculture (USDA) standards for food safety. Using a training set of 200 samples and testing set of 100 samples, the best neural network model demonstrated a classification accuracy of 98% for normal samples and 94% for septicemia/toxemia samples. These results show that Vis/NIR spectral methods have potential for use in chicken liver inspection as part of automated online systems for food safety inspection. Liver abnormalities are identifying characteristics of the septox condition; consequently, liver screening would be extremely useful as part of an automated inspection system to meet USDA food safety requirements for poultry. Automated inspection systems capable of real-time on-line operation are currently being developed, and spectroscopic liver inspection is potential tool that could be implemented as part of such systems to help poultry processors increase production while meeting food safety inspection requirements.

  17. Infrared Spectroscopic Characteristics and Ionic Occupations in Crystalline Tunneling System of Yellow Beryl

    Science.gov (United States)

    Yu, Xiaoyan; Hu, Dingyu; Niu, Xiaowei; Kang, Weirui

    2017-04-01

    Infrared spectroscopic characteristics and ionic occupations in a crystalline tunneling system of yellow beryl crystals from Inner Mongolia, China, were investigated by standard gemological methods, laser ablation inductively coupled plasma mass spectrometry, x-ray diffraction, ultraviolet-visible (UV-Vis) spectrophotometry, and infrared (IR) spectroscopy in this study. The refractive index, specific gravity, and chemical composition of the samples are shown within the range of natural yellow beryls previously reported. The unit cell dimensions of the beryls are 9.208-9.212 Å for a and 9.105-9.206 Å for c with a ratio of c/a = 0.9985-0.9994. The beryl samples are generally alkali-poor beryls with Fe UV-Vis spectra showed an absorption band at 689 nm, and all polarized IR spectra of samples displayed a 7217-cm-1 infrared absorption in the studied samples which was associated with irradiation of the coloration. This treatment of color irradiation can be detected from the beryl channels with 689-nm absorption and 7217-cm-1 infrared absorption.

  18. Investigation of fungal deterioration of synthetic paint binders using vibrational spectroscopic techniques.

    Science.gov (United States)

    Cappitelli, Francesca; Vicini, Silvia; Piaggio, Paolo; Abbruscato, Pamela; Princi, Elisabetta; Casadevall, Arturo; Nosanchuk, Joshua D; Zanardini, Elisabetta

    2005-01-14

    The deterioration of synthetic polymers caused by biological process is usually evaluated by visual inspection and measuring physical effects. In contrast to this approach, we have applied vibrational spectroscopies to study the biodegradation of the synthetic resins. 29 synthetic resins used as paint binding media, including acrylic, alkyd and poly(vinyl acetate) polymers, were examined for potential susceptibility to fungal degradation using the standard method ASTM G21-96(2002). In addition, the degraded resins were analysed by Raman spectroscopy, FT-IR and FT-IR photoacoustic spectroscopy. Almost all the acrylic resins studied proved to be resistant to microbial attack, while all alkyd resins and some poly(vinyl acetates) turned out to be biodegradable. Within a few days of inoculation Aspergillus niger was the most copious fungus on the biodegraded resins. A comparison of the IR and Raman spectra of control and biodegraded resins did not show any differences, but photoacoustic spectroscopy revealed additional bands for the fungal-degraded resins, consistent with the presence of fungal-derived substances. The additional bands in the photoacoustic spectra were due to the presence of Aspergillus niger and melanin, a fungal pigment. Since IR photoacoustic spectroscopy can be also a suitable technique for the chemical characterisation of binding media, the same spectroscopic analysis can be employed to both characterise the material and obtain evidence for fungal colonization. Microbial growth on Sobral 1241ML (alkyd resin) after 28 d (growth rating 4) compared with the non-inoculated resin.

  19. NMR spectroscopic and analytical ultracentrifuge analysis of membrane protein detergent complexes

    Directory of Open Access Journals (Sweden)

    Choe Senyon

    2007-11-01

    Full Text Available Abstract Background Structural studies of integral membrane proteins (IMPs are hampered by inherent difficulties in their heterologous expression and in the purification of solubilized protein-detergent complexes (PDCs. The choice and concentrations of detergents used in an IMP preparation play a critical role in protein homogeneity and are thus important for successful crystallization. Results Seeking an effective and standardized means applicable to genomic approaches for the characterization of PDCs, we chose 1D-NMR spectroscopic analysis to monitor the detergent content throughout their purification: protein extraction, detergent exchange, and sample concentration. We demonstrate that a single NMR measurement combined with a SDS-PAGE of a detergent extracted sample provides a useful gauge of the detergent's extraction potential for a given protein. Furthermore, careful monitoring of the detergent content during the process of IMP production allows for a high level of reproducibility. We also show that in many cases a simple sedimentation velocity measurement provides sufficient data to estimate both the oligomeric state and the detergent-to-protein ratio in PDCs, as well as to evaluate the homogeneity of the samples prior to crystallization screening. Conclusion The techniques presented here facilitate the screening and selection of the extraction detergent, as well as help to maintain reproducibility in the detergent exchange and PDC concentration procedures. Such reproducibility is particularly important for the optimization of initial crystallization conditions, for which multiple purifications are routinely required.

  20. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    Science.gov (United States)

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  1. Differential diagnosis of breast masses in South Korean premenopausal women using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Leproux, Anaïs; Kim, You Me; Min, Jun Won; McLaren, Christine E.; Chen, Wen-Pin; O'Sullivan, Thomas D.; Lee, Seung-ha; Chung, Phil-Sang; Tromberg, Bruce J.

    2016-07-01

    Young patients with dense breasts have a relatively low-positive biopsy rate for breast cancer (˜1 in 7). South Korean women have higher breast density than Westerners. We investigated the benefit of using a functional and metabolic imaging technique, diffuse optical spectroscopic imaging (DOSI), to help the standard of care imaging tools to distinguish benign from malignant lesions in premenopausal Korean women. DOSI uses near-infrared light to measure breast tissue composition by quantifying tissue concentrations of water (ctH2O), bulk lipid (ctLipid), deoxygenated (ctHHb), and oxygenated (ctHbO2) hemoglobin. DOSI spectral signatures specific to abnormal tissue and absent in healthy tissue were also used to form a malignancy index. This study included 19 premenopausal subjects (average age 41±9), corresponding to 11 benign and 10 malignant lesions. Elevated lesion to normal ratio of ctH2O, ctHHb, ctHbO2, total hemoglobin (THb=ctHHb+ctHbO2), and tissue optical index (ctHHb×ctH2O/ctLipid) were observed in the malignant lesions compared to the benign lesions (p90% sensitivity and specificity. Malignant lesions showed significantly higher metabolism and perfusion than benign lesions. DOSI spectral features showed high discriminatory power for distinguishing malignant and benign lesions in dense breasts of the Korean population.

  2. Understanding reactivity of two newly synthetized imidazole derivatives by spectroscopic characterization and computational study

    Science.gov (United States)

    Hossain, Mossaraf; Thomas, Renjith; Mary, Y. Sheena; Resmi, K. S.; Armaković, Stevan; Armaković, Sanja J.; Nanda, Ashis Kumar; Vijayakumar, G.; Van Alsenoy, C.

    2018-04-01

    Two newly synthetized imidazole derivatives (1-(4-methoxyphenyl)-4,5-dimethyl-1H-imidazole-2-yl acetate (MPDIA) and 1-(4-bromophenyl)-4,5-dimethyl-1H-imidazole-2-yl acetate (BPDIA)) have been prepared by solvent-free synthesis pathway and their specific spectroscopic and reactive properties have been discussed based on combined experimental and computational approaches. Aside of synthesis, experimental part of this work included measurements of IR, FT-Raman and NMR spectra. All of the aforementioned spectra were also obtained computationally, within the framework of density functional theory (DFT) approach. Additionally, DFT calculations have been used in order to investigate local reactivity properties based on molecular orbital theory, molecular electrostatic potential (MEP), average local ionization energy (ALIE), Fukui functions and bond dissociation energy (BDE). Molecular dynamics (MD) simulations have been used in order to obtain radial distribution functions (RDF), which were used for identification of the atoms with pronounced interactions with water molecules. MEP showed negative regions are mainly localized over N28, O29, O35 atoms, it is represent with red colour in rainbow color scheme for MPDIA and BPDIA (which are most reactive sites for electrophilic attack). The first order hyperpolarizabilities of MPDIA and BPDIA are 20.15 and 6.10 times that of the standard NLO material urea. Potential interaction with antihypertensive protein hydrolase.

  3. Novel spectroscopic methods for determination of Cromolyn sodium and Oxymetazoline hydrochloride in binary mixture

    Science.gov (United States)

    Abdel-Aziz, Omar; El-Kosasy, A. M.; Magdy, N.; El Zahar, N. M.

    2014-10-01

    New accurate, sensitive and selective spectrophotometric and spectrofluorimetric methods were developed and subsequently validated for determination of Cromolyn sodium (CS) and Oxymetazoline HCl (OXY) in binary mixture. These methods include ‘H-point standard addition method (HPSAM) and area under the curve (AUC)' spectrophotometric method and first derivative synchronous fluorescence spectroscopic (FDSFS) method. For spectrophotometric methods, absorbances were recorded at 241.5 nm and 274.9 nm for HPSAM and the wavelength was selected in ranges 232.0-254.0 nm and 216.0-229.0 nm for AUC method, where the concentration was obtained by applying Cramer's rule. For FDSFS method, the first-derivative synchronous fluorescence signal was measured at 290.0 nm, using Δλ = 145.0 nm. The suggested methods were validated according to International Conference of Harmonization (ICH) guidelines and the results revealed that they were precise and reproducible. All the obtained results were statistically compared with those of the reported method and there was no significant difference.

  4. Automated Spectroscopic Analysis Using the Particle Swarm Optimization Algorithm: Implementing a Guided Search Algorithm to Autofit

    Science.gov (United States)

    Ervin, Katherine; Shipman, Steven

    2017-06-01

    While rotational spectra can be rapidly collected, their analysis (especially for complex systems) is seldom straightforward, leading to a bottleneck. The AUTOFIT program was designed to serve that need by quickly matching rotational constants to spectra with little user input and supervision. This program can potentially be improved by incorporating an optimization algorithm in the search for a solution. The Particle Swarm Optimization Algorithm (PSO) was chosen for implementation. PSO is part of a family of optimization algorithms called heuristic algorithms, which seek approximate best answers. This is ideal for rotational spectra, where an exact match will not be found without incorporating distortion constants, etc., which would otherwise greatly increase the size of the search space. PSO was tested for robustness against five standard fitness functions and then applied to a custom fitness function created for rotational spectra. This talk will explain the Particle Swarm Optimization algorithm and how it works, describe how Autofit was modified to use PSO, discuss the fitness function developed to work with spectroscopic data, and show our current results. Seifert, N.A., Finneran, I.A., Perez, C., Zaleski, D.P., Neill, J.L., Steber, A.L., Suenram, R.D., Lesarri, A., Shipman, S.T., Pate, B.H., J. Mol. Spec. 312, 13-21 (2015)

  5. Using radio astronomical receivers for molecular spectroscopic characterization in astrochemical laboratory simulations: A proof of concept

    Science.gov (United States)

    Tanarro, I.; Alemán, B.; de Vicente, P.; Gallego, J. D.; Pardo, J. R.; Santoro, G.; Lauwaet, K.; Tercero, F.; Díaz-Pulido, A.; Moreno, E.; Agúndez, M.; Goicoechea, J. R.; Sobrado, J. M.; López, J. A.; Martínez, L.; Doménech, J. L.; Herrero, V. J.; Hernández, J. M.; Peláez, R. J.; López-Pérez, J. A.; Gómez-González, J.; Alonso, J. L.; Jiménez, E.; Teyssier, D.; Makasheva, K.; Castellanos, M.; Joblin, C.; Martín-Gago, J. A.; Cernicharo, J.

    2018-01-01

    We present a proof of concept on the coupling of radio astronomical receivers and spectrometers with chemical reactors and the performances of the resulting setup for spectroscopy and chemical simulations in laboratory astrophysics. Several experiments including cold plasma generation and UV photochemistry were performed in a 40 cm long gas cell placed in the beam path of the Aries 40 m radio telescope receivers operating in the 41-49 GHz frequency range interfaced with fast Fourier transform spectrometers providing 2 GHz bandwidth and 38 kHz resolution. The impedance matching of the cell windows has been studied using different materials. The choice of the material and its thickness was critical to obtain a sensitivity identical to that of standard radio astronomical observations. Spectroscopic signals arising from very low partial pressures of CH3OH, CH3CH2OH, HCOOH, OCS, CS, SO2 (fragmentation experiments using electron impact or UV irradiation. Time evolution of chemical reactions involving OCS, O2 and CS2 was also observed demonstrating that reactive species, such as CS, can be maintained with high abundance in the gas phase during these experiments. Movies are available at http://www.aanda.org

  6. Spectroscopic characterization, antimicrobial activity, DFT computation and docking studies of sulfonamide Schiff bases

    Science.gov (United States)

    Mondal, Sudipa; Mandal, Santi M.; Mondal, Tapan Kumar; Sinha, Chittaranjan

    2017-01-01

    Schiff bases synthesised from the condensation of 2-(hydroxy)naphthaldehyde and sulfonamides (sufathiazole (STZ), sulfapyridine (SPY), sulfadiazine (SDZ), sulfamerazine (SMZ) and sulfaguanidine (SGN)) are characterized by different spectroscopic data (FTIR, UV-Vis, Mass, NMR) and two of them, (E)-4-(((2-hydroxynaphthalen-1-yl)methylene)amino)-N-(thiazol-2-yl)benzenesulfonamide (1a) and (E)-N-(diaminomethylene)-4-(((2-hydroxynaphthalen-1-yl)methylene)amino)benzenesulfonamide (1e) have been confirmed by single crystal X-ray structure determination. Antimicrobial activities of the Schiff bases have been evaluated against certified and resistant Gram positive (Staphylococcus aureus, Enterococcus facelis) and Gram negative (Streptococcus pyogenes, Salmonella typhi, Shigella dysenteriae, Shigella flexneri, Klebsiella pneumonia) pathogens. Performance of Schiff base against the resistant pathogens are better than standard stain and MIC data lie 32-128 μg/ml while parent sulfonamides are effectively inactive (MIC >512 μg/ml). The DFT optimized structures of the Schiff bases have been used to accomplish molecular docking studies with DHPS (dihydropteroate synthase) protein structure (downloaded from Protein Data Bank) to establish the most preferred mode of interaction. ADMET filtration, Cytotoxicity (MTT assay) and haemolysis assay have been examined for evaluation of druglike character.

  7. Novel spectroscopic methods for determination of Cromolyn sodium and Oxymetazoline hydrochloride in binary mixture.

    Science.gov (United States)

    Abdel-Aziz, Omar; El-Kosasy, A M; Magdy, N; El Zahar, N M

    2014-10-15

    New accurate, sensitive and selective spectrophotometric and spectrofluorimetric methods were developed and subsequently validated for determination of Cromolyn sodium (CS) and Oxymetazoline HCl (OXY) in binary mixture. These methods include 'H-point standard addition method (HPSAM) and area under the curve (AUC)' spectrophotometric method and first derivative synchronous fluorescence spectroscopic (FDSFS) method. For spectrophotometric methods, absorbances were recorded at 241.5nm and 274.9nm for HPSAM and the wavelength was selected in ranges 232.0-254.0nm and 216.0-229.0nm for AUC method, where the concentration was obtained by applying Cramer's rule. For FDSFS method, the first-derivative synchronous fluorescence signal was measured at 290.0nm, using Δλ=145.0nm. The suggested methods were validated according to International Conference of Harmonization (ICH) guidelines and the results revealed that they were precise and reproducible. All the obtained results were statistically compared with those of the reported method and there was no significant difference. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Spectroscopic characterization of novel fluorescent lipid membrane probes

    International Nuclear Information System (INIS)

    Knapp, M.

    2001-11-01

    The aim of this thesis was the spectroscopic characterization of new, so far not described fluorescence markers which incorporate into ordered systems and provide information about their structure, the phase transition and aggregation. Bianthryl, Anthracen and Coumarin 6 were incorporated into liposomes formed from Lecithine, DMPC or DPPC as well as β-Cyclodextrin. The systems were characterized by means of classical-spectroscopic methods, laser-induced fluorescence and fluorescence correlation spectroscopy (FCS). Because of the prospective phyto-physical characteristics of bianthryl, i.e. the formation of a charge-separated electronic exited state this probe is particularly suitable to detect small changes of micro viscosity and local polarity of liposomes. Due to three clearly separated fluorescence lifetimes of the excited singlet state, measured for Bianthryl, three specific sites of this molecule within the phospholipid membrane were proven. Coumarin 6 incorporates likewise very well in Liposomes. The thermotrope phase transition at temperature 24,5 o C is well provable by the change of the anisotropy of fluorescence of this laser dye. By time-resolved anisotropy measurements the dynamics (rotation) was proven with high sensitivity. The thermotropic phase transition of DMPC Liposomes was detected by means of fluorescence reasonance energy transfer (FRET). A specific method for the determination of fluorescence quantum yields in strongly scattering solutions was suggested on the basis of FRET using Anthracen as energy donor and coumarin 6 as energy acceptor. For the energy transfer of Anthracen to Coumarin 6 in the gel phase of the DMPC liposomes as substantial proportion of static transfer was found. The presence of correlated donor-acceptor pairs was proven by the comparison of stationary and time-resolved fluorescence. Further more, concentration- and temperature dependent formation was found of anthracene dimers. Such dimers are formed in the gel phase of

  9. Spectroscopic Studies on Complex Formation of U(VI)-thiosalicylate

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Wan Sik; Cho, Hye Ryun; Park, Kyoung Kyun; Jung, Euo Chang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    The dynamic interaction between radionuclides and organic ligands is largely dependent on the composition of functional groups in a ligand chemical structure. Therefore, the structural mimics of natural ligands possessing specific functional groups, such as hydroxy, phenol, carboxyl, thiol and amine groups, have been studied to understand their influence on the migration of radionuclides including actinide species under geological groundwater conditions. In previous studies, we demonstrated that the fraction of hydrolyzed U(VI) species occurring in weak acidic solutions (pH {approx}4.5) is significantly influenced by the presence of salicylate (Sal) ligand due to the simultaneous participation of both phenol and carboxyl groups in the formation of U(VI)-complexes. Thiosalicylic acid (TSalH{sub 2}) is a good model compound for studying the effects of both carboxyl and thiol (-SH) groups. The fraction of di-anionic ligand form (TSal{sup 2-}) is higher at near neutral pH due to the lower pKa ({approx} 8) of the thiol group than the case of salicylic acid (pKa, {approx}13 for salicylic -OH), despite the structural similarity. In addition, the redox capability of the thiol group is expected to influence the reducible radiouclides and the chemical structures of natural ligands by creating cross-linkage (-S-S-) upon oxidation. The goal of the present study is to investigate aqueous U(VI)-TSal complexation equilibrium via laser-based spectroscopic techniques including time resolved laser-induced fluorescence spectroscopy (TRLFS). In this preliminary work, we report the results of spectroscopic studies using conventional UVVis absorbance and fluorescence (FL) measurement methods. The photo-stability of U(VI)-TSal complex or ligand itself upon exposure to a series of laser pulses is estimated by monitoring the change in their absorption bands. Additionally, TSal FL-quenching effect by U(VI) ions is discussed in comparison with that of Sal FL-quenching

  10. Raman spectroscopic analysis of a `noli me tangere' painting

    Science.gov (United States)

    Hibberts, Stephen; Edwards, Howell G. M.; Abdel-Ghani, Mona; Vandenabeele, Peter

    2016-12-01

    The discovery of an oil painting in seriously damaged condition with an important historical and a heterodox detail with possible origins in the late fifteenth century has afforded the opportunity for Raman microscopic analysis prior to its restoration being undertaken. The painting depicts a risen Christ following His crucifixion in a `noli me tangere' pose with three women in an Italian terrace garden with a stone balustrade overlooking a rural landscape and an undoubted view of late-medieval Florence. The picture has suffered much abuse and is in very poor condition, which is possibly attributable to its controversial portrayal of a polydactylic Christ with six toes on His right foot. By the late sixteenth century, after the Council of Trent, this portrayal would almost certainly have been frowned upon by the Church authorities or more controversially as a depiction of the holy. Raman spectroscopic analysis of the pigments places the painting as being consistent chronologically with the Renaissance period following the identification of cinnabar, haematite, red lead, lead white, goethite, verdigris, caput mortuum and azurite with no evidence of more modern synthetic pigments or of modern restoration having been carried out. An interesting pigment mixture found here is that of the organic dye carmine and cinnabar to produce a particular bright red pigment coloration. Stratigraphic examination of the paint fragments has demonstrated the presence of an orange resin layer immediately on top of the canvas substrate, effectively rendering the pigment as a sandwich between this substratal resin and the overlying varnish. The Raman spectroscopic evidence clearly indicates that an attribution of the artwork to the Renaissance is consistent with the scientific analysis of the pigment composition. This article is part of the themed issue "Raman spectroscopy in art and archaeology".

  11. Detection of spectroscopic binaries in the Gaia-ESO Survey

    Science.gov (United States)

    Van der Swaelmen, M.; Merle, T.; Van Eck, S.; Jorissen, A.

    2017-12-01

    The Gaia-ESO survey (GES) is a ground-based spectroscopic survey, complementing the Gaia mission, in order to obtain high accuracy radial velocities and chemical abundances for 10^5 stars. Thanks to the numerous spectra collected by the GES, the detection of spectroscopic multiple system candidates (SBn, n ≥ 2) is one of the science case that can be tackled. We developed at IAA (Institut d'Astronomie et d'Astrophysique) a novative automatic method to detect multiple components from the cross-correlation function (CCF) of spectra and applied it to the CCFs provided by the GES. Since the bulk of the Milky Way field targets has been observed in both HR10 and HR21 GIRAFFE settings, we are also able to compare the efficiency of our SB detection tool depending on the wavelength range. In particular, we show that HR21 leads to a less efficient detection compared to HR10. The presence of strong and/or saturated lines (Ca II triplet, Mg I line, Paschen lines) in the wavelength domain covered by HR21 hampers the computation of CCFs, which tend to be broadened compared to their HR10 counterpart. The main drawback is that the minimal detectable radial velocity difference is ˜ \\SI{60}km/s for HR21 while it is ˜ \\SI{25}km/s for HR10. A careful design of CCF masks (especially masking Ca triplet lines) can substantially improve the detectability rate of HR21. Since HR21 spectra are quite similar to the one produced by the RVS spectrograph of the Gaia mission, analysis of RVS spectra in the context of spectroscpic binaries can take adavantage of the lessons learned from the GES to maximize the detection rate.

  12. Development of a Neutron Spectroscopic System Utilizing Compressed Sensing Measurements

    Directory of Open Access Journals (Sweden)

    Vargas Danilo

    2016-01-01

    Full Text Available A new approach to neutron detection capable of gathering spectroscopic information has been demonstrated. The approach relies on an asymmetrical arrangement of materials, geometry, and an ability to change the orientation of the detector with respect to the neutron field. Measurements are used to unfold the energy characteristics of the neutron field using a new theoretical framework of compressed sensing. Recent theoretical results show that the number of multiplexed samples can be lower than the full number of traditional samples while providing the ability to have some super-resolution. Furthermore, the solution approach does not require a priori information or inclusion of physics models. Utilizing the MCNP code, a number of candidate detector geometries and materials were modeled. Simulations were carried out for a number of neutron energies and distributions with preselected orientations for the detector. The resulting matrix (A consists of n rows associated with orientation and m columns associated with energy and distribution where n < m. The library of known responses is used for new measurements Y (n × 1 and the solver is able to determine the system, Y = Ax where x is a sparse vector. Therefore, energy spectrum measurements are a combination of the energy distribution information of the identified elements of A. This approach allows for determination of neutron spectroscopic information using a single detector system with analog multiplexing. The analog multiplexing allows the use of a compressed sensing solution similar to approaches used in other areas of imaging. A single detector assembly provides improved flexibility and is expected to reduce uncertainty associated with current neutron spectroscopy measurement.

  13. Raman spectroscopic analysis of a 'noli me tangere' painting.

    Science.gov (United States)

    Hibberts, Stephen; Edwards, Howell G M; Abdel-Ghani, Mona; Vandenabeele, Peter

    2016-12-13

    The discovery of an oil painting in seriously damaged condition with an important historical and a heterodox detail with possible origins in the late fifteenth century has afforded the opportunity for Raman microscopic analysis prior to its restoration being undertaken. The painting depicts a risen Christ following His crucifixion in a 'noli me tangere' pose with three women in an Italian terrace garden with a stone balustrade overlooking a rural landscape and an undoubted view of late-medieval Florence. The picture has suffered much abuse and is in very poor condition, which is possibly attributable to its controversial portrayal of a polydactylic Christ with six toes on His right foot. By the late sixteenth century, after the Council of Trent, this portrayal would almost certainly have been frowned upon by the Church authorities or more controversially as a depiction of the holy. Raman spectroscopic analysis of the pigments places the painting as being consistent chronologically with the Renaissance period following the identification of cinnabar, haematite, red lead, lead white, goethite, verdigris, caput mortuum and azurite with no evidence of more modern synthetic pigments or of modern restoration having been carried out. An interesting pigment mixture found here is that of the organic dye carmine and cinnabar to produce a particular bright red pigment coloration. Stratigraphic examination of the paint fragments has demonstrated the presence of an orange resin layer immediately on top of the canvas substrate, effectively rendering the pigment as a sandwich between this substratal resin and the overlying varnish. The Raman spectroscopic evidence clearly indicates that an attribution of the artwork to the Renaissance is consistent with the scientific analysis of the pigment composition.This article is part of the themed issue 'Raman spectroscopy in art and archaeology'. © 2016 The Author(s).

  14. THE YOUNG SOLAR ANALOGS PROJECT. I. SPECTROSCOPIC AND PHOTOMETRIC METHODS AND MULTI-YEAR TIMESCALE SPECTROSCOPIC RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Gray, R. O.; Briley, M. M.; Lambert, R. A.; Fuller, V. A.; Newsome, I. M.; Seeds, M. F. [Department of Physics and Astronomy, Appalachian State University, Boone, NC 26808 (United States); Saken, J. M.; Kahvaz, Y. [Department of Physics and Physical Science, Marshall University, Huntington, WV 25755 (United States); Corbally, C. J. [Vatican Observatory Research Group, Steward Observatory, Tucson, AZ 85721-0065 (United States)

    2015-12-15

    This is the first in a series of papers presenting methods and results from the Young Solar Analogs Project, which began in 2007. This project monitors both spectroscopically and photometrically a set of 31 young (300–1500 Myr) solar-type stars with the goal of gaining insight into the space environment of the Earth during the period when life first appeared. From our spectroscopic observations we derive the Mount Wilson S chromospheric activity index (S{sub MW}), and describe the method we use to transform our instrumental indices to S{sub MW} without the need for a color term. We introduce three photospheric indices based on strong absorption features in the blue-violet spectrum—the G-band, the Ca i resonance line, and the Hydrogen-γ line—with the expectation that these indices might prove to be useful in detecting variations in the surface temperatures of active solar-type stars. We also describe our photometric program, and in particular our “Superstar technique” for differential photometry which, instead of relying on a handful of comparison stars, uses the photon flux in the entire star field in the CCD image to derive the program star magnitude. This enables photometric errors on the order of 0.005–0.007 magnitude. We present time series plots of our spectroscopic data for all four indices, and carry out extensive statistical tests on those time series demonstrating the reality of variations on timescales of years in all four indices. We also statistically test for and discover correlations and anti-correlations between the four indices. We discuss the physical basis of those correlations. As it turns out, the “photospheric” indices appear to be most strongly affected by emission in the Paschen continuum. We thus anticipate that these indices may prove to be useful proxies for monitoring emission in the ultraviolet Balmer continuum. Future papers in this series will discuss variability of the program stars on medium (days–months) and short

  15. Agent Standards Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation of the work herein proposed is the development of standards for software autonomous agents. These standards are essential to achieve software...

  16. Catalytic Functions of Standards

    NARCIS (Netherlands)

    K. Blind (Knut)

    2009-01-01

    textabstractThe three different areas and the examples have illustrated several catalytic functions of standards for innovation. First, the standardisation process reduces the time to market of inventions, research results and innovative technologies. Second, standards themselves promote the

  17. BTS statistical standards manual

    Science.gov (United States)

    2005-10-01

    The Bureau of Transportation Statistics (BTS), like other federal statistical agencies, establishes professional standards to guide the methods and procedures for the collection, processing, storage, and presentation of statistical data. Standards an...

  18. Dental Assisting Program Standards.

    Science.gov (United States)

    Georgia Univ., Athens. Dept. of Vocational Education.

    This publication contains statewide standards for the dental assisting program in Georgia. The standards are divided into 12 categories: foundations (philosophy, purpose, goals, program objectives, availability, evaluation); admissions (admission requirements, provisional admission requirements, recruitment, evaluation and planning); program…

  19. The Distance Standard Deviation

    OpenAIRE

    Edelmann, Dominic; Richards, Donald; Vogel, Daniel

    2017-01-01

    The distance standard deviation, which arises in distance correlation analysis of multivariate data, is studied as a measure of spread. New representations for the distance standard deviation are obtained in terms of Gini's mean difference and in terms of the moments of spacings of order statistics. Inequalities for the distance variance are derived, proving that the distance standard deviation is bounded above by the classical standard deviation and by Gini's mean difference. Further, it is ...

  20. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  1. Quality of semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.

    2012-01-01

    Little scientific literature addresses the issue of quality of semantic standards, albeit a problem with high economic and social impact. Our problem survey, including 34 semantic Standard Setting Organizations (SSOs), gives evidence that quality of standards can be improved, but for improvement a

  2. Automotive Technology Skill Standards

    Science.gov (United States)

    Garrett, Tom; Asay, Don; Evans, Richard; Barbie, Bill; Herdener, John; Teague, Todd; Allen, Scott; Benshoof, James

    2009-01-01

    The standards in this document are for Automotive Technology programs and are designed to clearly state what the student should know and be able to do upon completion of an advanced high-school automotive program. Minimally, the student will complete a three-year program to achieve all standards. Although these exit-level standards are designed…

  3. [Ophthalmology and standardization].

    Science.gov (United States)

    Heitz, R

    1989-01-01

    The standards are the references for quality and safety of materials, instruments and devices in ophtalmological use. The French standardisation association, "Association Française de Normalisation" (AFNOR), drafts his standards in connection with the concerned professionals. The ophthalmologists are concerned by standards of diagnostic and therapeutic instruments, intraocular and orbital implants, contact lenses, spectacle frames and glasses, and ocular protectors.

  4. Fourier transform Raman spectroscopic characterisation of cells of the plant-associated soil bacterium Azospirillum brasilense Sp7

    Science.gov (United States)

    Kamnev, A. A.; Tarantilis, P. A.; Antonyuk, L. P.; Bespalova, L. A.; Polissiou, M. G.; Colina, M.; Gardiner, P. H. E.; Ignatov, V. V.

    2001-05-01

    Structural and compositional features of bacterial cell samples and of lipopolysaccharide-protein complex isolated from the cell surface of the plant-growth-promoting rhizobacterium Azospirillum brasilense (wild-type strain Sp7) were characterised using Fourier transform (FT) Raman spectroscopy. The structural spectroscopic information obtained is analysed and considered together with analytical data on the content of metal cations (Co 2+, Cu 2+ and Zn 2+) in the bacterial cells grown in a standard medium as well as in the presence of each of the cations (0.2 mM). The latter, being taken up by bacterial cells from the culture medium in significant amounts, were shown to induce certain metabolic changes in the bacterium revealed in FT-Raman spectra, which is discussed from the viewpoint of bacterial response to environmental stresses.

  5. The retention of calcium, barium, and strontium ions by a mollisol humic acid: Spectroscopic investigation

    Science.gov (United States)

    Oufqir, Sofia; Bloom, Paul R.; Torner, Brandy M.

    2014-05-01

    Humic substances have a major role in controlling the mobility and bioavailability of metallic ions in soils and natural waters. The alkaline earth metals, calcium, barium, and strontium, are broadly abundant in the crust of the earth, and Ca2+ ions are known to be important in the formation of structural aggregates in soils. Yet, direct spectroscopic evidence of how Ca, Ba, and Sr ions interact with soil organic matter, is minimal. To develop a deeper understanding of the interaction of the alkaline earth cations in soil, we studied the complexation behavior of strontium, barium and calcium by humic acid (HA) using solid-state 13C CP-MAS NMR, FTIR and extended x-ray absorption fine structure (EXAFS) spectroscopy. A HA sample was extracted from an agricultural mollisol (pH 6, 32.5% clay content, 3.7% organic carbon) located in southwestern Minnesota, USA, by the standard NaOH method. The HA sample was treated with chloride salts of Ca, Sr or Ba, then freeze-dried prior to spectroscopic measurements. The FTIR spectra, obtained using pressed KBr disks, and the 13C NMR spectra revealed spectral differences, stemming mainly from deprotonation reactions of the carboxylic and phenolic groups of the HA. The association of Ca, Ba, and Sr ions with the HA caused a marked FTIR shift of the carboxylate band, with the Ba shift being the most pronounced (HA 1604.7; HA-Ca 1595.1; HA-Sr 1597; HA-Ba 1579.6), which seems to imply that Ba is the strongest bound element. An NMR shift of the carbonyl peak at 171.8 ppm was also observed to 174.5 for Ca, 173.7 for Sr, and 174.4 for Ba confirming that these cations are behaving differently towards soil HA. The EXAFS spectra indicated back-scattering from oxygen atoms, in the first shell, for Ca, Sr, and Ba with varied coordination number. Our data prove that (1) the carboxylates and phenolates are the prevailing functional groups involved in the interactions between the extracted HA and alkali metal cations, (2) barium forms the

  6. Differentiation of tissue and kidney stones for laser lithotripsy using different spectroscopic approaches

    Science.gov (United States)

    Lange, Birgit; Cordes, Jens; Brinkmann, Ralf

    2015-07-01

    Holmium lasers are nowadays the gold standard for endoscopic laser lithotripsy. However, there is a risk of damaging or perforating the ureter or kidney tissue when the vision is poor. An automatic tissue/stone differentiation would improve the handling and safety of the procedure. To achieve this objective, an easy and robust real-time discrimination method has to be found which can be used to realize a feedback loop to control the laser system. Two possible approaches have been evaluated: White light reflectance and fluorescence spectroscopy. In both cases, we use the treatment fiber for detection and evaluate the possibility to decide whether the fiber is placed in front of tissue or calculus by the signal that is delivered by the surface in front of it. White light reflectance spectroscopy uses the standard light source for endourologic surgeries: Radiation of a Xenon light source is coupled to the ureteroscope via a liquid light guide. The part of the white light that is reflected back into the fiber is spectroscopically analyzed. In a clinical proof of concept study reflection signals were measured in vivo in 8 patients. For differentiation of stone and tissue via autofluorescence, excitation as well as detection was done via the treatment fiber. A suitable excitation wavelength was chosen with in vitro measurements (UV / visible) on several human renal calculi and porcine tissues. For verification of the positive results with green excitation in a clinical proof of concept study, a measurement set-up was realized which allows the recording of fluorescence signals during an endourological intervention.

  7. Spectroscopic characterization of galaxy clusters in RCS-1: spectroscopic confirmation, redshift accuracy, and dynamical mass-richness relation

    Science.gov (United States)

    Gilbank, David G.; Barrientos, L. Felipe; Ellingson, Erica; Blindert, Kris; Yee, H. K. C.; Anguita, T.; Gladders, M. D.; Hall, P. B.; Hertling, G.; Infante, L.; Yan, R.; Carrasco, M.; Garcia-Vergara, Cristina; Dawson, K. S.; Lidman, C.; Morokuma, T.

    2018-05-01

    We present follow-up spectroscopic observations of galaxy clusters from the first Red-sequence Cluster Survey (RCS-1). This work focuses on two samples, a lower redshift sample of ˜30 clusters ranging in redshift from z ˜ 0.2-0.6 observed with multiobject spectroscopy (MOS) on 4-6.5-m class telescopes and a z ˜ 1 sample of ˜10 clusters 8-m class telescope observations. We examine the detection efficiency and redshift accuracy of the now widely used red-sequence technique for selecting clusters via overdensities of red-sequence galaxies. Using both these data and extended samples including previously published RCS-1 spectroscopy and spectroscopic redshifts from SDSS, we find that the red-sequence redshift using simple two-filter cluster photometric redshifts is accurate to σz ≈ 0.035(1 + z) in RCS-1. This accuracy can potentially be improved with better survey photometric calibration. For the lower redshift sample, ˜5 per cent of clusters show some (minor) contamination from secondary systems with the same red-sequence intruding into the measurement aperture of the original cluster. At z ˜ 1, the rate rises to ˜20 per cent. Approximately ten per cent of projections are expected to be serious, where the two components contribute significant numbers of their red-sequence galaxies to another cluster. Finally, we present a preliminary study of the mass-richness calibration using velocity dispersions to probe the dynamical masses of the clusters. We find a relation broadly consistent with that seen in the local universe from the WINGS sample at z ˜ 0.05.

  8. Spectroscopic Characterisation of Galaxy Clusters in RCS-1: spectroscopic confirmation, redshift accuracy, and dynamical mass-richness relation

    Science.gov (United States)

    Gilbank, David G.; Felipe Barrientos, L.; Ellingson, Erica; Blindert, Kris; Yee, H. K. C.; Anguita, T.; Gladders, M. D.; Hall, P. B.; Hertling, G.; Infante, L.; Yan, R.; Carrasco, M.; Garcia-Vergara, Cristina; Dawson, K. S.; Lidman, C.; Morokuma, T.

    2018-02-01

    We present follow-up spectroscopic observations of galaxy clusters from the first Red-sequence Cluster Survey (RCS-1). This work focuses on two samples, a lower redshift sample of ˜30 clusters ranging in redshift from z˜0.2-0.6 observed with multi-object spectroscopy (MOS) on 4-6.5-m class telescopes and a z˜1 sample of ˜10 clusters 8-m class telescope observations. We examine the detection efficiency and redshift accuracy of the now widely-used red-sequence technique for selecting clusters via overdensities of red-sequence galaxies. Using both these data and extended samples including previously-published RCS-1 spectroscopy and spectroscopic redshifts from SDSS, we find that the red-sequence redshift using simple two-filter cluster photometric redshifts is accurate to σz ≈ 0.035(1 + z) in RCS-1. This accuracy can potentially be improved with better survey photometric calibration. For the lower redshift sample, ˜5% of clusters show some (minor) contamination from secondary systems with the same red-sequence intruding into the measurement aperture of the original cluster. At z˜1 the rate rises to ˜20%. ˜10% of projections are expected to be serious, where the two components contribute significant numbers of their red-sequence galaxies to another cluster. Finally, we present a preliminary study of the mass-richness calibration using velocity dispersions to probe the dynamical masses of the clusters. We find a relation broadly consistent with that seen in the local universe from the WINGS sample at z˜0.05.

  9. Spectroscopic properties of a two-dimensional time-dependent Cepheid model. II. Determination of stellar parameters and abundances

    Science.gov (United States)

    Vasilyev, V.; Ludwig, H.-G.; Freytag, B.; Lemasle, B.; Marconi, M.

    2018-03-01

    Context. Standard spectroscopic analyses of variable stars are based on hydrostatic 1D model atmospheres. This quasi-static approach has not been theoretically validated. Aim. We aim at investigating the validity of the quasi-static approximation for Cepheid variables. We focus on the spectroscopic determination of the effective temperature Teff, surface gravity log g, microturbulent velocity ξt, and a generic metal abundance log A, here taken as iron. Methods: We calculated a grid of 1D hydrostatic plane-parallel models covering the ranges in effective temperature and gravity that are encountered during the evolution of a 2D time-dependent envelope model of a Cepheid computed with the radiation-hydrodynamics code CO5BOLD. We performed 1D spectral syntheses for artificial iron lines in local thermodynamic equilibrium by varying the microturbulent velocity and abundance. We fit the resulting equivalent widths to corresponding values obtained from our dynamical model for 150 instances in time, covering six pulsational cycles. In addition, we considered 99 instances during the initial non-pulsating stage of the temporal evolution of the 2D model. In the most general case, we treated Teff, log g, ξt, and log A as free parameters, and in two more limited cases, we fixed Teff and log g by independent constraints. We argue analytically that our approach of fitting equivalent widths is closely related to current standard procedures focusing on line-by-line abundances. Results: For the four-parametric case, the stellar parameters are typically underestimated and exhibit a bias in the iron abundance of ≈-0.2 dex. To avoid biases of this type, it is favorable to restrict the spectroscopic analysis to photometric phases ϕph ≈ 0.3…0.65 using additional information to fix the effective temperature and surface gravity. Conclusions: Hydrostatic 1D model atmospheres can provide unbiased estimates of stellar parameters and abundances of Cepheid variables for particular

  10. Characterization of a spectroscopic detector for application in x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, A. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fix, B. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brown, W. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Azevedo, S. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martz, H. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-21

    Recent advances in cadmium telluride (CdTe) energy-discriminating pixelated detectors have enabled the possibility of Multi-Spectral X-ray Computed Tomography (MSXCT) to incorporate spectroscopic information into CT. MultiX ME 100 V2 is a CdTe-based spectroscopic x-ray detector array capable of recording energies from 20 to 160 keV in 1.1 keV energy bin increments. Hardware and software have been designed to perform radiographic and computed tomography tasks with this spectroscopic detector. Energy calibration is examined using the end-point energy of a bremsstrahlung spectrum and radioisotope spectral lines. When measuring the spectrum from Am-241 across 500 detector elements, the standard deviation of the peak-location and FWHM measurements are ±0.4 and ±0.6 keV, respectively. As these values are within the energy bin size (1.1 keV), detector elements are consistent with each other. The count rate is characterized, using a nonparalyzable model with a dead time of 64 ± 5 ns. This is consistent with the manufacturer’s quoted per detector-element linear-deviation at 2 Mpps (million photons per sec) of 8.9% (typical) and 12% (max). When comparing measured and simulated spectra, a low-energy tail is visible in the measured data due to the spectral response of the detector. If no valid photon detections are expected in the low-energy tail, then a background subtraction may be applied to allow for a possible first-order correction. If photons are expected in the low-energy tail, a detailed model must be implemented. A radiograph of an aluminum step wedge with a maximum height of about 20 mm shows an underestimation of attenuation by about 10% at 60 keV. This error is due to partial energy deposition from higher-energy (> 60 keV) photons into a lower-energy (~60 keV) bin, reducing the apparent attenuation. A radiograph of a PTFE cylinder taken using a bremsstrahlung spectrum from an x-ray voltage of 100 kV filtered by 1.3 mm Cu is reconstructed using Abel inversion

  11. Characterization of a spectroscopic detector for application in x-ray computed tomography

    Science.gov (United States)

    Dooraghi, Alex A.; Fix, Brian J.; Smith, Jerel A.; Brown, William D.; Azevedo, Stephen G.; Martz, Harry E.

    2017-09-01

    Recent advances in cadmium telluride (CdTe) energy-discriminating pixelated detectors have enabled the possibility of Multi-Spectral X-ray Computed Tomography (MSXCT) to incorporate spectroscopic information into CT. MultiX ME 100 V2 is a CdTe-based spectroscopic x-ray detector array capable of recording energies from 20 to 160 keV in 1.1 keV energy bin increments. Hardware and software have been designed to perform radiographic and computed tomography tasks with this spectroscopic detector. Energy calibration is examined using the end-point energy of a bremsstrahlung spectrum and radioisotope spectral lines. When measuring the spectrum from Am-241 across 500 detector elements, the standard deviation of the peak-location and FWHM measurements are +/- 0.4 and +/- 0.6 keV, respectively. As these values are within the energy bin size (1.1 keV), detector elements are consistent with each other. The count rate is characterized, using a nonparalyzable model with a dead time of 64 +/- 5 ns. This is consistent with the manufacturer's quoted per detector-element linear-deviation at 2 Mpps (million photons per sec) of 8.9 % (typical) and 12 % (max). When comparing measured and simulated spectra, a low-energy tail is visible in the measured data due to the spectral response of the detector. If no valid photon detections are expected in the low-energy tail, then a background subtraction may be applied to allow for a possible first-order correction. If photons are expected in the low-energy tail, a detailed model must be implemented. A radiograph of an aluminum step wedge with a maximum height of 20 mm shows an underestimation of attenuation by about 10 % at 60 keV. This error is due to partial energy deposition from higher energy (>60 keV) photons into a lower-energy ( 60 keV) bin, reducing the apparent attenuation. A radiograph of a polytetrafluoroethylene (PTFE) cylinder taken using a bremsstrahlung spectrum from an x-ray voltage of 100 kV filtered by 1.3 mm Cu is

  12. Polarized spectroscopic properties of Nd3+-doped KGd(WO4)2 single crystal

    International Nuclear Information System (INIS)

    Chen Yujin; Lin Yanfu; Gong Xinghong; Tan Qiguang; Zhuang Jian; Luo Zundu; Huang Yidong

    2007-01-01

    The polarized absorption spectra, infrared fluorescence spectra, upconversion visible fluorescence spectra, and fluorescence decay curve of orientated Nd 3+ :KGd(WO 4 ) 2 crystal were measured at room-temperature. Some important spectroscopic parameters were investigated in detail in the framework of the Judd-Ofelt theory and the Fuchtbauer-Ladenburg formula. The effect of the crystal structure on the spectroscopic properties of the Nd 3+ ions was analyzed. The relation among the spectroscopic parameters and the laser performances of the Nd 3+ :KGd(WO 4 ) 2 crystal was discussed

  13. Spectroscopic properties with a combined approach of ab initio molecular dynamics and wavelet analysis

    Science.gov (United States)

    Pagliai, Marco; Muniz-Miranda, Francesco; Cardini, Gianni; Righini, Roberto; Schettino, Vincenzo

    2011-05-01

    In order to extract spectroscopic information from trajectories obtained by classical or ab initio molecular dynamics simulations, usually Fourier transforms are employed. In recent years wavelet transforms have been shown to be a valid alternative tool to analyze time-series, due to their capability of localizing a signal both in time and frequency. In this article wavelet transforms are applied for the analysis of Car-Parrinello molecular dynamics simulations to the purpose of time-correlating structural and spectroscopic properties of methyl acetate dissolved in water and methanol. The results demonstrate the possibility of obtaining information that may be of valuable help in the interpretation of time-resolved spectroscopic data.

  14. Spectroscopic quantification of extremely rare molecular species in the presence of interfering optical absorption

    Science.gov (United States)

    Ognibene, Ted; Bench, Graham; McCartt, Alan Daniel; Turteltaub, Kenneth; Rella, Chris W.; Tan, Sze; Hoffnagle, John A.; Crosson, Eric

    2017-05-09

    Optical spectrometer apparatus, systems, and methods for analysis of carbon-14 including a resonant optical cavity configured to accept a sample gas including carbon-14, an optical source configured to deliver optical radiation to the resonant optical cavity, an optical detector configured to detect optical radiation emitted from the resonant cavity and to provide a detector signal; and a processor configured to compute a carbon-14 concentration from the detector signal, wherein computing the carbon-14 concentration from the detector signal includes fitting a spectroscopic model to a measured spectrogram, wherein the spectroscopic model accounts for contributions from one or more interfering species that spectroscopically interfere with carbon-14.

  15. Requirements of quality standards

    International Nuclear Information System (INIS)

    Mueller, J.

    1977-01-01

    The lecture traces the development of nuclear standards, codes, and Federal regulations on quality assurance (QA) for nuclear power plants and associated facilities. The technical evolution of the last twelve years, especially in the area of nuclear technology, led to different activities and regulatory initiatives, and the present result is: several nations have their own homemade standards. The lecture discusses the former and especially current activities in standard development, and gives a description of the requirements of QA-standards used in USA and Europe, especially Western Germany. Furthermore the lecture attempts to give a comparison and an evaluation of the international quality standards from the author's viewpoint. Finally the lecture presents an outlook for the future international implications of QA-standards. There is an urgent need within the nuclear industry for simplification and standardization of QA-standards. The relationship between the various standards, and the applicability of the standards need clarification and a better transparancy. To point out these problems is the purpose of the lecture. (orig.) [de

  16. Quantitative spectroscopic analysis of and distance to SN1999em

    Science.gov (United States)

    Dessart, L.; Hillier, D. J.

    2006-02-01

    Multi-epoch multi-wavelength spectroscopic observations of photospheric-phase type II supernovae (SN) provide information on massive-star progenitor properties, the core-collapse mechanism, and distances in the Universe. Following successes of recent endeavors (Dessart & Hillier 2005a, A&A, 437, 667; 2005b, A&A, 439, 671) with the non-LTE model atmosphere code CMFGEN (Hillier & Miller 1998, ApJ, 496, 407), we present a detailed quantitative spectroscopic analysis of the type II SN1999em and, using the Expanding Photosphere Method (EPM) or synthetic fits to observed spectra, à la Baron et al. (2004, ApJ, 616, 91), we estimate its distance. Selecting eight epochs, which cover the first 38 days after discovery, we obtain satisfactory fits to optical spectroscopic observations of SN1999em (including the UV and near-IR ranges when available). We use the same iron-group metal content for the ejecta, the same power-law density distribution (with exponent n = 10{-}12), and a Hubble-velocity law at all times. We adopt a H/He/C/N/O abundance pattern compatible with CNO-cycle equilibrium values for a RSG/BSG progenitor, with C/O enhanced and N depleted at later times. The overall evolution of the spectral energy distribution, whose peak shifts to longer wavelengths as time progresses, reflects the steady temperature/ionization-level decrease of the ejecta, associated non-linearly with a dramatic shift to ions with stronger line-blocking powers in the UV and optical (Fe ii, Tiii). In the parameter space investigated, CMFGEN is very sensitive and provides photospheric temperatures and velocities, reddenings, and the H/He abundance ratio with an accuracy of ±500 K, ±10%, 0.05 and 50%, respectively. Following Leonard et al. (2002, PASP, 114, 35), and their use of correction factors from Hamuy et al. (2001, ApJ, 558, 615), we estimate an EPM distance to SN1999em that also falls 30% short of the Cepheid distance of 11.7 Mpc to its host galaxy NGC 1637 (Leonard et al. 2003, Ap

  17. Beyond the standard model

    International Nuclear Information System (INIS)

    Wilczek, F.

    1993-01-01

    The standard model of particle physics is highly successful, although it is obviously not a complete or final theory. In this presentation the author argues that the structure of the standard model gives some quite concrete, compelling hints regarding what lies beyond. Essentially, this presentation is a record of the author's own judgement of what the central clues for physics beyond the standard model are, and also it is an attempt at some pedagogy. 14 refs., 6 figs

  18. Standard Model processes

    CERN Document Server

    Mangano, M.L.; Aguilar-Saavedra, Juan Antonio; Alekhin, S.; Badger, S.; Bauer, C.W.; Becher, T.; Bertone, V.; Bonvini, M.; Boselli, S.; Bothmann, E.; Boughezal, R.; Cacciari, M.; Carloni Calame, C.M.; Caola, F.; Campbell, J.M.; Carrazza, S.; Chiesa, M.; Cieri, L.; Cimaglia, F.; Febres Cordero, F.; Ferrarese, P.; D'Enterria, D.; Ferrera, G.; Garcia i Tormo, X.; Garzelli, M.V.; Germann, E.; Hirschi, V.; Han, T.; Ita, H.; Jäger, B.; Kallweit, S.; Karlberg, A.; Kuttimalai, S.; Krauss, F.; Larkoski, A.J.; Lindert, J.; Luisoni, G.; Maierhöfer, P.; Mattelaer, O.; Martinez, H.; Moch, S.; Montagna, G.; Moretti, M.; Nason, P.; Nicrosini, O.; Oleari, C.; Pagani, D.; Papaefstathiou, A.; Petriello, F.; Piccinini, F.; Pierini, M.; Pierog, T.; Pozzorini, S.; Re, E.; Robens, T.; Rojo, J.; Ruiz, R.; Sakurai, K.; Salam, G.P.; Salfelder, L.; Schönherr, M.; Schulze, M.; Schumann, S.; Selvaggi, M.; Shivaji, A.; Siodmok, A.; Skands, P.; Torrielli, P.; Tramontano, F.; Tsinikos, I.; Tweedie, B.; Vicini, A.; Westhoff, S.; Zaro, M.; Zeppenfeld, D.; CERN. Geneva. ATS Department

    2017-06-22

    This report summarises the properties of Standard Model processes at the 100 TeV pp collider. We document the production rates and typical distributions for a number of benchmark Standard Model processes, and discuss new dynamical phenomena arising at the highest energies available at this collider. We discuss the intrinsic physics interest in the measurement of these Standard Model processes, as well as their role as backgrounds for New Physics searches.

  19. Governing through standards

    DEFF Research Database (Denmark)

    Brøgger, Katja

    This abstract adresses the ways in which new education standards have become integral to new modes of education governance. The paper explores the role of standards for accelerating the shift from national to transnational governance in higher education. Drawing on the case of higher education...... development in Scandinavia, the paper focuses on the unintended effects of the new international standards. The Bologna process was reframed and recontextualized in ways that undermined the very system it was set out to transform and govern....

  20. Continuing ARAS visible spectroscopic monitoring of the slow classical nova Sct 2017 = ASASSN-17hx

    Science.gov (United States)

    Guarro, Joan; Berardi, Paolo; Sollecchia, Umberto; Lester, Tim; Bohlsen, Terry; Luckas, Paul; Campos, Fran; Franco, Lorenzo; Garde, Olivier; Buil, Christian; Edlin, Jim; Teyssier, François

    2017-09-01

    We report the results of our continuing spectroscopic monitoring of the slow classical nova Sct 2017 = ASASSN-17hx (Atel# 10523, #10524, #10527, #10558, #10736) as part of the ongoing program by members of the ARAS group.

  1. UV-fluorescence spectroscopic technique in the diagnosis of breast, ovarian, uterus, and cervix cancer

    Science.gov (United States)

    Das, Bidyut B.; Glassman, Wenling S.; Alfano, Robert R.; Cleary, Joseph; Prudente, R.; Celmer, Edward J.; Lubicz, Stephanie

    1991-06-01

    Malignant breast tumors can be separated from benign and normal tissues using uv-fluorescence spectroscopic technique. Using the same method one can also distinguish cancerous tissues from noncancerous ones in case of cervix, uterus and ovary.

  2. Cosmological Parameter Constraints from the Dark Energy Survey Supernova Program Three Year Spectroscopic Sample.

    Science.gov (United States)

    Brout, Dillon

    2018-01-01

    We present cosmological parameter constraints from 251 spectroscopically confirmed Type Ia Supernovae (0.02 Supernova Program (DESSN). The photometric calibration, scene modeling photometric pipeline, additional low-z supernovae samples (zcosmological results and systematics analysis are discussed.

  3. An empirical evaluation of three vibrational spectroscopic methods for detection of aflatoxins in maize.

    Science.gov (United States)

    Lee, Kyung-Min; Davis, Jessica; Herrman, Timothy J; Murray, Seth C; Deng, Youjun

    2015-04-15

    Three commercially available vibrational spectroscopic techniques, including Raman, Fourier transform near infrared reflectance (FT-NIR), and Fourier transform infrared (FTIR) were evaluated to help users determine the spectroscopic method best suitable for aflatoxin analysis in maize (Zea mays L.) grain based on their relative efficiency and predictive ability. Spectral differences of Raman and FTIR spectra were more marked and pronounced among aflatoxin contamination groups than those of FT-NIR spectra. From the observations and findings in our current and previous studies, Raman and FTIR spectroscopic methods are superior to FT-NIR method in terms of predictive power and model performance for aflatoxin analysis and they are equally effective and accurate in predicting aflatoxin concentration in maize. The present study is considered as the first attempt to assess how spectroscopic techniques with different physical processes can influence and improve accuracy and reliability for rapid screening of aflatoxin contaminated maize samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. The Standard Model course

    CERN Multimedia

    CERN. Geneva HR-RFA

    2006-01-01

    Suggested Readings: Aspects of Quantum Chromodynamics/A Pich, arXiv:hep-ph/0001118. - The Standard Model of Electroweak Interactions/A Pich, arXiv:hep-ph/0502010. - The Standard Model of Particle Physics/A Pich The Standard Model of Elementary Particle Physics will be described. A detailed discussion of the particle content, structure and symmetries of the theory will be given, together with an overview of the most important experimental facts which have established this theoretical framework as the Standard Theory of particle interactions.

  5. International hearing protector standardization

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2002-01-01

    Hearing protectors shall fulfill some minimum requirements to their performance. As hearing protector manufacturers sell the products all over the world, the testing and certification of hearing protectors has become an international issue. The ISO working group WG17 under the headlines Acoustics......, Noise, produce hearing protector standards to be used at an international level. The presentation will cover the ongoing work in WG17, including the revision of existing standards (ISO 4869-1, ISO 4869-3), upcoming new standards (ISO 4869-7) and the plans and status for future standards (performance...

  6. Standardization: colorfull or dull?

    Science.gov (United States)

    van Nes, Floris L.

    2003-01-01

    After mentioning the necessity of standardization in general, this paper explains how human factors, or ergonomics standardization by ISO and the deployment of information technology were linked. Visual display standardization is the main topic; the present as well as the future situation in this field are treated, mainly from an ISO viewpoint. Some observations are made about the necessary and interesting co-operation between physicists and psychologists, of different nationality, who both may be employed by either private enterprise or governmental institutions, in determining visual display requirements. The display standard that is to succeed the present ISO standards in this area: ISO 9241-3, -7, -8 and ISO 13406-1, -2, will have a scope that is not restricted to office tasks. This means a large extension of the contexts for which display requirements have to be investigated and specified especially if mobile use of displays, under outdoor lighting conditions, is included. The new standard will be structured in such a way that it is better accessible than the present ones for different categories of standards users. The subject color in the new standard is elaborated here. A number of questions are asked as to which requirements on color rendering should be made, taking new research results into account, and how far the new standard should go in making recommendations to the display user.

  7. Standard NIM instrumentation system

    CERN Document Server

    1990-01-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID- 20893 (Rev 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice.

  8. Spectroscopic Survey of the Low Mass Population in the Star-Forming Region Lagoon Nebula

    Science.gov (United States)

    Kalari, Venu; Vink, J. S.; GAIA-ESO Survey

    2017-06-01

    Using data from the GAIA-ESO spectroscopic survey, we describe the determination of spectroscopic and stellar parameters of circa 400 low-mass members of the Lagoon Nebula. Based on this analysis, we discuss the luminosity/age spread in the H-R diagram, lithium evolution and place in our findings in context of recent theoretical and observational works. We also compare our results with time-series and near-mid infrared data.

  9. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations are nece......Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations...

  10. Development of a Biosensor Nanofluidic Platform for Integration with Terahertz Spectroscopic System

    Science.gov (United States)

    2014-06-27

    understanding of the interaction between THz radiation and biomaterials will become possible and open the door to development of all optical, highly...nanofluidic sensor platform effective for label-free "THz-frequency spectroscopic fingerprinting " of biological molecules for detection, identification...demonstration of a nanofluidic sensor platform effective for label-free "THz-frequency spectroscopic fingerprinting " of biological molecules for detection

  11. VizieR Online Data Catalog: UVEX sources spectroscopic follow-up (Verbeek+, 2012)

    Science.gov (United States)

    Verbeek, K.; Groot, P. J.; Scaringi, S.; Napiwotzki, R.; Spikings, B.; Ostensen, R. H.; Drew, J. E.; Steeghs, D.; Casares, J.; Corral-Santana, J. M.; Corradi, R. L. M.; Deacon, N.; Drake, J. J.; Gansicke, B. T.; Gonzalez-Solares, E.; Greimel, R.; Heber, U.; Irwin, M. J.; Knigge, C.; Nelemans, G.

    2013-04-01

    Spectroscopic follow-up was obtained by three different telescopes for a total of 132 UV-excess candidates during a number of observing runs. For 100 UV-excess candidates spectroscopic observations were obtained, during two runs in 2009 September and 2010 December, with the Intermediate dispersion Spectrograph and Imaging System (ISIS) mounted at the 4.2m William Herschel Telescope (WHT) at Roque de los Muchachos Observatory on the island of La Palma. (3 data files).

  12. Spectroscopic factors within an algebraic model and an application to 12C+12C

    International Nuclear Information System (INIS)

    Hess, P. O.; Aguilera, E. F.; Martinez-Quiroz, E.; Algora, A.; Cseh, J.; Draayer, J. P.; Belyaeva, T. L.

    2007-01-01

    A parameterization of the spectroscopic factor is presented which almost matches the ones obtained via the microscopic SU(3) model of the nucleus. A short introduction of the algebraic model (the Semimicroscopic Algebraic Cluster Model, SACM) is given. The parameterization of the spectroscopic factor is explained, justified and compared, for light nuclei, to the microscopic SU(3) model. The applications concern the calculation of the total fusion cross section of 12C+12C

  13. UV/IR Filaments for High Resolution Novel Spectroscopic Interrogation of Plumes on Nuclear Materials

    Science.gov (United States)

    2016-06-01

    6201 Fort Belvoir, VA 22060-6201 T E C H N IC A L R E P O R T DTRA-TR-16-66 UV/ IR filaments for high resolution novel spectroscopic...by the factor to get the U.S. customary unit. UV/ IR filaments for high resolution novel spectroscopic Interrogation of Plumes on nuclear materials...10 5.1 UV filaments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.2 IR filaments

  14. A spectroscopic study of absorption and emission features of interstellar dust components

    International Nuclear Information System (INIS)

    Zwet, G.P. van der.

    1986-01-01

    The spectroscopic properties of silicate interstellar dust grains are the subject of this thesis. The process of accretion and photolysis is simulated in the laboratory by condensing mixtures of gases onto a cold substrate (T ∼ 12 K) in a vacuum chamber and photolyzing these mixtures with a vacuum ultraviolet source. Alternatively, the gas mixtures may be passed through a microwave discharge first, before deposition. The spectroscopic properties of the ices are investigated using ultraviolet, visible and infrared spectroscopy. (Auth.)

  15. The Data-Driven Approach to Spectroscopic Analyses

    Science.gov (United States)

    Ness, M.

    2018-01-01

    I review the data-driven approach to spectroscopy, The Cannon, which is a method for deriving fundamental diagnostics of galaxy formation of precise chemical compositions and stellar ages, across many stellar surveys that are mapping the Milky Way. With The Cannon, the abundances and stellar parameters from the multitude of stellar surveys can be placed directly on the same scale, using stars in common between the surveys. Furthermore, the information that resides in the data can be fully extracted, this has resulted in higher precision stellar parameters and abundances being delivered from spectroscopic data and has opened up new avenues in galactic archeology, for example, in the determination of ages for red giant stars across the Galactic disk. Coupled with Gaia distances, proper motions, and derived orbit families, the stellar age and individual abundance information delivered at the precision obtained with the data-driven approach provides very strong constraints on the evolution of and birthplace of stars in the Milky Way. I will review the role of data-driven spectroscopy as we enter the era where we have both the data and the tools to build the ultimate conglomerate of galactic information as well as highlight further applications of data-driven models in the coming decade.

  16. Spectroscopic studies of anthracyclines: Structural characterization and in vitro tracking.

    Science.gov (United States)

    Szafraniec, Ewelina; Majzner, Katarzyna; Farhane, Zeineb; Byrne, Hugh J; Lukawska, Malgorzata; Oszczapowicz, Irena; Chlopicki, Stefan; Baranska, Malgorzata

    2016-12-05

    A broad spectroscopic characterization, using ultraviolet-visible (UV-vis) and Fourier transform infrared absorption as well as Raman scattering, of two commonly used anthracyclines antibiotics (DOX) daunorubicin (DNR), their epimers (EDOX, EDNR) and ten selected analogs is presented. The paper serves as a comprehensive spectral library of UV-vis, IR and Raman spectra of anthracyclines in the solid state and in solution. The particular advantage of Raman spectroscopy for the measurement and analysis of individual antibiotics is demonstrated. Raman spectroscopy can be used to monitor the in vitro uptake and distribution of the drug in cells, using both 488nm and 785nm as source wavelengths, with submicrometer spatial resolution, although the cellular accumulation of the drug is different in each case. The high information content of Raman spectra allows studies of the drug-cell interactions, and so the method seems very suitable for monitoring drug uptake and mechanisms of interaction with cellular compartments at the subcellular level. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. High Energy Solar Spectroscopic Imager (HESSI) Team Investigations

    Science.gov (United States)

    Emslie, A. Gordon

    1998-01-01

    This report covers activities on the above grant for the period through the end of September 1997. The work originally proposed to be performed under a three-year award was converted at that time to a two-year award for the remainder of the period, and is now funded under award NAGS-4027 through Goddard Space Flight Center. The P.I. is a co-investigator on the High Energy Solar Spectroscopic Imager (HESSI) team, selected as a Small-Class Explorer (SNMX) mission in 1997. He has also been a participant in the Space Physics Roadmap Planning Group. Our research has been strongly influenced by the NASA mission opportunities related to these activities. The report is subdivided into four sections, each dealing with a different aspect of our research within this guiding theme. Personnel involved in this research at UAH include the P.I. and graduate students Michele Montgomery and Amy Winebarger. Much of the work has been carried out in collaboration with investigators at other institutions, as detailed below. Attachment: Laser wakefield acceleration and astrophysical applications.

  18. Near-Infrared Spectroscopic Study of Chlorite Minerals

    Directory of Open Access Journals (Sweden)

    Min Yang

    2018-01-01

    Full Text Available The mineral chemistry of twenty chlorite samples from the United States Geological Survey (USGS spectral library and two other regions, having a wide range of Fe and Mg contents and relatively constant Al and Si contents, was studied via infrared (IR spectroscopy, near-infrared (NIR spectroscopy, and X-ray fluorescence (XRF analysis. Five absorption features of the twenty samples near 4525, 4440, 4361, 4270, and 4182 cm−1 were observed, and two diagnostic features at 4440 and 4280 cm−1 were recognized. Assignments of the two diagnostic features were made for two combination bands (ν+δAlAlO−OH and ν+δSiAlO−OH by regression with IR fundamental absorptions. Furthermore, the determinant factors of the NIR band position were found by comparing the band positions with relative components. The results showed that Fe/(Fe + Mg values are negatively correlated with the two NIR combination bands. The findings provide an interpretation of the NIR band formation and demonstrate a simple way to use NIR spectroscopy to discriminate between chlorites with different components. More importantly, spectroscopic detection of mineral chemical variations in chlorites provides geologists with a tool with which to collect information on hydrothermal alteration zones from hyperspectral-resolution remote sensing data.

  19. Chemical and spectroscopic analysis of lignin in isolated flax fibers.

    Science.gov (United States)

    Morrison, W H; Himmelsbach, D S; Akin, D E; Evans, J D

    2003-04-23

    The chemistry of pure flax fibers, free of contaminating nonfiber components, has not been determined. Fibers from the center sections of the stem of seed and fiber flax (Linum usitatissium L.), which had been retted after soaking in water and removal of the epidermis by hand, underwent chemical and spectroscopic analysis. Wet chemical analysis showed only trace indications of aromatics and no long chain fatty acids or alcohols in fibers. Pyrolysis mass spectroscopy (PyMS) and pyrolysis gas chromatography mass spectrometry (PyGCMS) showed only trace amounts of aromatic constituents that could be attributed to the presence of lignin. Mid-infrared (Mid-IR) and Raman spectroscopy of these fibers showed no aromatic compounds present. This study suggests that earlier work reporting the presence of lignin ranging from 1 to 4% may be the result of residual shive or epidermis/cuticle material remaining after the retting process which may be responsible for the favorable properties desired by the composites industry.

  20. Structure and linear spectroscopic properties of near IR polymethine dyes

    International Nuclear Information System (INIS)

    Webster, Scott; Padilha, Lazaro A.; Hu Honghua; Przhonska, Olga V.; Hagan, David J.; Van Stryland, Eric W.; Bondar, Mikhail V.; Davydenko, Iryna G.; Slominsky, Yuriy L.; Kachkovski, Alexei D.

    2008-01-01

    We performed a detailed experimental investigation and quantum-chemical analysis of a new series of near IR polymethine dyes with 5-butyl-7,8-dihydrobenzo[cd]furo[2,3-f]indolium terminal groups. We also synthesized and studied two neutral dyes, squaraine and tetraone, with the same terminal groups and performed a comparison of the spectroscopic properties of this set of 'near IR' dyes (polymethine, squaraine, and tetraone) with an analogous set of 'visible' dyes with simpler benzo[e]indolium terminal groups. From these measurements, we find that the dyes with dihydrobenzo[cd]furo[2,3-f]indolium terminal groups are characterized by a remarkably large shift ∼300 nm (∼200 nm for tetraone) of their absorption bands towards the red region. We discuss the difference in electronic structure for these molecules and show that the 'near IR' dyes are characterized by an additional weak fluorescence band from the higher lying excited states connected with the terminal groups. Absorption spectra for the longest polymethines are solvent-dependent and are characterized by a broadening of the main band in polar solvents, which is explained by ground state symmetry breaking and reduced charge delocalization within the polymethine chromophore. The results of these experiments combined with the agreement of quantum chemical calculations moves us closer to a predictive capability for structure-property relations in cyanine-like molecules

  1. Spectroscopic follow-up of the Hercules-Aquila Cloud

    Science.gov (United States)

    Simion, Iulia T.; Belokurov, Vasily; Koposov, Sergey E.; Sheffield, Allyson; Johnston, Kathryn V.

    2018-05-01

    We designed a follow-up program to find the spectroscopic properties of the Hercules-Aquila Cloud (HAC) and test scenarios for its formation. We measured the radial velocities (RVs) of 45 RR Lyrae in the southern portion of the HAC using the facilities at the MDM observatory, producing the first large sample of velocities in the HAC. We found a double-peaked distribution in RVs, skewed slightly to negative velocities. We compared both the morphology of HAC projected on to the plane of the sky and the distribution of velocities in this structure outlined by RR Lyrae and other tracer populations at different distances to N-body simulations. We found that the behaviour is characteristic of an old, well-mixed accretion event with small apo-galactic radius. We cannot yet rule out other formation mechanisms for the HAC. However, if our interpretation is correct, HAC represents just a small portion of a much larger debris structure spread throughout the inner Galaxy whose distinct kinematic structure should be apparent in RV studies along many lines of sight.

  2. Time-resolved infrared spectroscopic techniques as applied to Channelrhodopsin

    Directory of Open Access Journals (Sweden)

    Eglof eRitter

    2015-07-01

    Full Text Available Among optogenetic tools, channelrhodopsins, the light gated ion channels of the plasma membrane from green algae, play the most important role. Properties like channel selectivity, timing parameters or color can be influenced by the exchange of selected amino acids. Although widely used, in the field of neurosciences for example, there is still little known about their photocycles and the mechanism of ion channel gating and conductance. One of the preferred methods for these studies is infrared spectroscopy since it allows observation of proteins and their function at a molecular level and in near-native environment. The absorption of a photon in channelrhodopsin leads to retinal isomerization within femtoseconds, the conductive states are reached in the microsecond time scale and the return into the fully dark-adapted state may take more than minutes. To be able to cover all these time regimes, a range of different spectroscopical approaches are necessary. This mini-review focuses on time-resolved applications of the infrared technique to study channelrhodopsins and other light triggered proteins. We will discuss the approaches with respect to their suitability to the investigation of channelrhodopsin and related proteins.

  3. Dielectric and impedance spectroscopic studies of neodymium gallate

    Energy Technology Data Exchange (ETDEWEB)

    Sakhya, Anup Pradhan, E-mail: npshakya31@gmail.com [Department of Physics, Bose Institute, 93/1 Acharya Prafulla Chandra Road, Kolkata 700009 (India); Dutta, Alo [Department of Condensed Matter Physics and Material Sciences, S. N. Bose National Centre for Basic Sciences, Block-JD, Sector-III, Salt Lake, Kolkata 700098 (India); Sinha, T.P. [Department of Physics, Bose Institute, 93/1 Acharya Prafulla Chandra Road, Kolkata 700009 (India)

    2016-05-01

    The AC electrical properties of a polycrystalline neodymium gallate, NdGaO{sub 3} (NGO), synthesized by the sol–gel method have been investigated by employing impedance spectroscopy in the frequency range from 42 Hz to 5 MHz and in the temperature range from 323 K to 593 K. The X-ray diffraction analysis shows that the compound crystallizes in the orthorhombic phase with Pbnm space group at room temperature. Two relaxation processes with different relaxation times are observed from the impedance as well as modulus spectroscopic measurements, which have been attributed to the grain and the grain boundary effects at different temperatures in NGO. The complex impedance data are analyzed by an electrical equivalent circuit consisting of a resistance and a constant phase element in parallel. It has been observed that the value of the capacitance and the resistance associated with the grain boundary is higher than those associated with the grain. The temperature dependent electrical conductivity shows the negative temperature coefficient of resistance. The frequency dependent conductivity spectra are found to follow the power law.

  4. Spectroscopic fast neutron transmission imaging in a treaty verification setting

    Directory of Open Access Journals (Sweden)

    K. Ogren

    2018-01-01

    Full Text Available Measurements of the geometric configuration of objects and their material composition are needed for nuclear treaty verification purposes. We experimentally demonstrate a simple method based on monoenergetic fast neutron transmission to realize crude imaging of the geometric configuration of special nuclear material, confirm its fissionable content, and obtain information on its approximate fissile mass. In the experiment, we used monoenergetic neutrons from D(d, n3He and T(d, n4He reactions and a linear array of liquid scintillation detectors to perform spectroscopic neutron imaging of up to 13.7 kg of highly enriched uranium in a spherical geometry. We also show an example of detection of material diversion and confirm the presence of fissionable material based on the measurement of high-energy prompt fission neutrons, including estimating the quantity of material from the comparison of measured and predicted fission neutron emission rate. The combination of crude imaging and fissionable material detection and quantification in a simple approach may be attractive in certain treaty verification scenarios.

  5. The Spectroscopic Orbit of the Planetary Companion Transiting HD 209458.

    Science.gov (United States)

    Mazeh; Naef; Torres; Latham; Mayor; Beuzit; Brown; Buchhave; Burnet; Carney; Charbonneau; Drukier; Laird; Pepe; Perrier; Queloz; Santos; Sivan; Udry; Zucker

    2000-03-20

    We report a spectroscopic orbit with period P=3.52433+/-0.00027 days for the planetary companion that transits the solar-type star HD 209458. For the metallicity, mass, and radius of the star, we derive [Fe/H&sqbr0;=0.00+/-0.02, M*=1.1+/-0.1 M middle dot in circle, and R*=1.2+/-0.1 R middle dot in circle. This is based on a new analysis of the iron lines in our HIRES template spectrum and also on the absolute magnitude, effective temperature, and color of the star, and it uses isochrones from four different sets of stellar evolution models. Using these values for the stellar parameters, we reanalyze the transit data and derive an orbital inclination of i=86&fdg;1+/-1&fdg;6. For the planet, we derive a mass of Mp=0.69+/-0.05 MJup, a radius of Rp=1.40+/-0.17 RJup, and a density of rho=0.31+/-0.07 g cm-3.

  6. Spectroscopic and electrochemical study of polynuclear clusters from ruthenium acetate

    International Nuclear Information System (INIS)

    Cipriano, C.

    1989-01-01

    The chemistry of the trinuclear clusters [Ru sub(3) O (CH sub(3) CO sub(2)) sub(4) L sub(3)] where L = imidazole, pyridine or pyrazine type of ligands, was investigated based on spectroscopic and electrochemical techniques. These complexes are of great interest from the point of view of their electronic and redox properties, providing multisite species for electron transfer processes. They were isolated in solid state, and characterized by means of elementary analyses and infrared spectra. The electrochemical behaviour in acetonitrile solution was typically reversible; the cyclic voltammograms exhibited a series of four or five mono electronic waves ascribed to the sucessive Ru sup(IV) Ru sup(III) Ru sup(III) / Ru sup(III) Ru sup(III) Ru sup(III)/ --- Ru sup(II) Ru sup(II) Ru sup(II) redox couples. The differences between the successive redox potentials were about 1 V, indicating strong metal-metal interaction in the trinuclear Ru sub(3) centre. The E values were strongly sensitive to the nature of the N-heterocyclic ligand, increasing with the pi-acceptor properties of the pyridine and pyrazine derivatives, but in a much less pronounced way in the case of the imidazole derivatives. Resonance Raman studies for the pyrazine cluster showed selective intensification of the vibrational modes of the Ru-pyrazine chromophore, and the trinuclear centre, using excitation wavelengths coinciding with the metal-to-pyrazine and metal-metal bands, respectively. (author)

  7. Spectroscopic study of small absorptions in optical coatings

    Science.gov (United States)

    Hansen, W. N.

    1982-07-01

    This report concerns research performed by the Utah University surface physics group for the Air Force Weapons Laboratory (AFWL), Kirtland Air Force Base, New Mexico. It is a supplement to AFWL-TR-79-197. It reports the continued study of thorium fluoride (ThF4) as an optical coating, showing that the moisture found in the ThF4 films probably originated from the preparation itself, and that ThF4 may not degrade by moisture absorption from the atmosphere as rapidly as previously thought. Further advances are reported in the characterization procedures themselves, including computer methods for data handling. New procedures were instituted for determining the optical constants of liquids. To test the procedures, the optical constants of liquid water were determined and compared with values found in literature. The procedures used are reported. A sample of Si3N4 film on germanium was analyzed spectroscopically. The dominant feature was a large infrared band revealing the presence of large amounts of silicon hydride. Finally, new procedures are reported for determining impurity concentrations in optical thin films which takes into account the local electromagnetic field strength seen by an impurity in a known optical material as matrix.

  8. Sparse spectral deconvolution algorithm for noncartesian MR spectroscopic imaging.

    Science.gov (United States)

    Bhave, Sampada; Eslami, Ramin; Jacob, Mathews

    2014-02-01

    To minimize line shape distortions and spectral leakage artifacts in MR spectroscopic imaging (MRSI). A spatially and spectrally regularized non-Cartesian MRSI algorithm that uses the line shape distortion priors, estimated from water reference data, to deconvolve the spectra is introduced. Sparse spectral regularization is used to minimize noise amplification associated with deconvolution. A spiral MRSI sequence that heavily oversamples the central k-space regions is used to acquire the MRSI data. The spatial regularization term uses the spatial supports of brain and extracranial fat regions to recover the metabolite spectra and nuisance signals at two different resolutions. Specifically, the nuisance signals are recovered at the maximum resolution to minimize spectral leakage, while the point spread functions of metabolites are controlled to obtain acceptable signal-to-noise ratio. The comparisons of the algorithm against Tikhonov regularized reconstructions demonstrates considerably reduced line-shape distortions and improved metabolite maps. The proposed sparsity constrained spectral deconvolution scheme is effective in minimizing the line-shape distortions. The dual resolution reconstruction scheme is capable of minimizing spectral leakage artifacts. Copyright © 2013 Wiley Periodicals, Inc.

  9. Spectroscopic properties of five-coordinated Co2+ in phosphates.

    Science.gov (United States)

    Hunault, M; Robert, J-L; Newville, M; Galoisy, L; Calas, G

    2014-01-03

    Co3(PO4)2, SrCo2(PO4)2, Co2P2O7, BaCoP2O7 and SrCoP2O7 present different geometries of five-coordinated Co(2+) (([5])Co(2+)) sites, coexisting with ([6])Co(2+) in Co3(PO4)2 and Co2P2O7, and ([4])Co(2+) in SrCo2(PO4)2. ([5])Co K-edge XANES spectra show that the intensity of the pre-edge and main-edge is intermediate between those of ([6])- and ([4])Co. Diffuse reflectance spectra show the contributions of Co(2+) in (D3h) symmetry for SrCo2(PO4)2, and (C4v) symmetry for BaCoP2O7 and SrCoP2O7. In Co3(PO4)2 and Co2P2O7 the multiple transitions observed arise from energy level splitting and may be labeled in (C2v) symmetry. Spectroscopic data confirm that (D3h) and (C4v) symmetries may be distinguished upon the intensity of the optical absorption bands and crystal field splitting values. We discuss the influence of the geometrical distortion and of the nature of the next nearest neighbors. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Spectroscopic observation and structure of CS2 dimer

    Science.gov (United States)

    Rezaei, M.; Norooz Oliaee, J.; Moazzen-Ahmadi, N.; McKellar, A. R. W.

    2011-04-01

    Infrared spectra of the CS2 dimer are observed in the region of the CS2 ν3 fundamental band (˜1535 cm-1) using a tunable diode laser spectrometer. The weakly bound complex is formed in a pulsed supersonic slit-jet expansion of a dilute gas mixture of carbon disulfide in helium. Contrary to the planar slipped-parallel geometry previously observed for (CO2)2, (N2O)2, and (OCS)2, the CS2 dimer exhibits a cross-shaped structure with D2d symmetry. Two bands were observed and analyzed: the fundamental (C-S asymmetric stretch) and a combination involving this mode plus an intermolecular vibration. In both cases, the rotational structure corresponds to a perpendicular (ΔK = ±1) band of a symmetric rotor molecule. The intermolecular center of mass separation (C-C distance) is determined to be 3.539(7) Å. Thanks to symmetry, this is the only parameter required to characterize the structure, if the monomer geometry is assumed to remain unchanged in the dimer. From the band centers of the fundamental and combination band an intermolecular frequency of 10.96 cm-1 is obtained, which we assign as the torsional bending mode. This constitutes the first high resolution spectroscopic investigation of CS2 dimer.

  11. Molecular docking, spectroscopic studies and quantum calculations on nootropic drug.

    Science.gov (United States)

    Uma Maheswari, J; Muthu, S; Sundius, Tom

    2014-04-05

    A systematic vibrational spectroscopic assignment and analysis of piracetam [(2-oxo-1-pyrrolidineacetamide)] have been carried out using FT-IR and FT-Raman spectral data. The vibrational analysis was aided by an electronic structure calculation based on the hybrid density functional method B3LYP using a 6-311G++(d,p) basis set. Molecular equilibrium geometries, electronic energies, IR and Raman intensities, and harmonic vibrational frequencies have been computed. The assignments are based on the experimental IR and Raman spectra, and a complete assignment of the observed spectra has been proposed. The UV-visible spectrum of the compound was recorded and the electronic properties, such as HOMO and LUMO energies and the maximum absorption wavelengths λmax were determined by the time-dependent DFT (TD-DFT) method. The geometrical parameters, vibrational frequencies and absorption wavelengths were compared with the experimental data. The complete vibrational assignments are performed on the basis of the potential energy distributions (PED) of the vibrational modes in terms of natural internal coordinates. The simulated FT-IR, FT-Raman, and UV spectra of the title compound have been constructed. Molecular docking studies have been carried out in the active site of piracetam by using Argus Lab. In addition, the potential energy surface, HOMO and LUMO energies, first-order hyperpolarizability and the molecular electrostatic potential have been computed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Expression, purification and spectroscopic characterization of the Regulator complex

    International Nuclear Information System (INIS)

    Nogueira, M.L.C.; Silva, A.L.S.; Camilotti, D.; Silva, C.A.; Sforca, M.L.; Smetana, J.H.C.; Zeri, A.C.; Ospina-Bedoya, M.

    2012-01-01

    Full text: The mammalian target of rapamycin (mTOR) signaling pathway integrates both intracellular and extracellular signals, serves as a central regulator of cell metabolism in humans and its deregulation is linked to diseases like cancer and diabetes. The small GTPases Rag are mediators of signaling by amino acid (leucine). These GT-Pases are anchored on the surface of the lysosome through an interaction with a complex of three proteins, p18, MP1 and p14, called Ragulator. The p18 protein is responsible for interaction with the lysosomal membrane through its N terminal post translational modification. The objective of this project is to study the interaction of p18 and other components of the Ragulator complex. The p18 protein was expressed in inclusion bodies, which were isolated and solubilized in urea. p18 was renatured with its partners MP1/p14 and this complex, the Ragulator, was subjected to spectroscopic characterization using circular dichroism and dynamic light scattering. (author)

  13. Spectroscopic Follow-Up of the Hercules Aquila Cloud

    Science.gov (United States)

    Simion, Iulia T.; Belokurov, Vasily; Koposov, Sergey E.; Sheffield, Allyson; Johnston, Kathryn V.

    2018-02-01

    We designed a follow-up program to find the spectroscopic properties of the Hercules-Aquila Cloud (HAC) and test scenarios for its formation. We measured the radial velocities (RVs) of 45 RR Lyrae in the southern portion of the HAC using the facilities at the MDM observatory, producing the first large sample of velocities in the HAC. We found a double-peaked distribution in RVs, skewed slightly to negative velocities. We compared both the morphology of HAC projected onto the plane of the sky and the distribution of velocities in this structure outlined by RR Lyrae and other tracer populations at different distances to N-body simulations. We found that the behaviour is characteristic of an old, well-mixed accretion event with small apo-galactic radius. We cannot yet rule out other formation mechanisms for the HAC. However, if our interpretation is correct, HAC represents just a small portion of a much larger debris structure spread throughout the inner Galaxy whose distinct kinematic structure should be apparent in RV studies along many lines of sight.

  14. Irradiation effects on canvas oil painting: Spectroscopic observations

    International Nuclear Information System (INIS)

    Manea, Mihaela Maria; Negut, C.D.; Stanculescu, Ioana Rodica; Ponta, C.C.

    2012-01-01

    “Winter” oil painting, by Romanian contemporary artist George Alexandrescu was used as experimental model for the substantiation of gamma radiation treatment, as the best choice to stop the biological attack of paintings. In this purpose, spectroscopic and colorimetric methods were used to analyse in situ, non-destructively and non-contact, the experimental model before and after 60 Co gamma irradiation. Chemical structure and colour changes were monitored by FTIR, FT-Raman and Vis reflectance spectroscopy. Negligible Infrared spectral transformations have been observed after irradiation. Furthermore, it was found that gamma irradiation did not induce any significant colour alterations. Insignificant structural and colour changes observed, recommend the use of gamma irradiation in the disinfection of oil paintings. - Highlights: ► Oil painting experimental model was gamma irradiated at 33 kGy. ► Changes induced by gamma irradiation were investigated in situ by spectral methods. ► Insignificant FT-IR/Raman spectral and colour variations were observed. ► Negligible changes recommend the irradiation for oil paintings disinfection.

  15. Spectroscopic laser parameters of Ag/CdTe nanostructure

    Energy Technology Data Exchange (ETDEWEB)

    Giba, A.E., E-mail: alaadin85@niles.edu.eg [Department of Laser Science and Interaction, National Institute of Laser Enhanced Science, Cairo University, 12613 Giza (Egypt); Gadallah, A.-S. [Department of Laser Science and Interaction, National Institute of Laser Enhanced Science, Cairo University, 12613 Giza (Egypt); Mohamed, M.B. [Department of Laser Applications in Metrology, Photochemistry & Agriculture, National Institute of Laser Enhanced Science, Cairo University, 12613 Giza (Egypt); Azzouz, I.M. [Department of Laser Science and Interaction, National Institute of Laser Enhanced Science, Cairo University, 12613 Giza (Egypt)

    2015-11-15

    We report spectroscopic laser parameters analysis for CdTe quantum dots (QDs) in the presence of Ag nanoparticles (NPs). Absorption and emission cross-sections of about 2 nm-particle size of aqueous CdTe QDs were estimated, when different contents of about 40 nm Ag nanoparticles were added. The fluorescence, radiative lifetimes and the energy transfer between Ag NPs and CdTe QDs have been investigated. Lasing parameters that evaluate the possibility of getting laser action for these nanomaterials were calculated. The energy transfer mechanism between Ag NPs and CdTe QDs was occurred by Forster resonance energy transfer (FRET) as the average distance between them is about 50 nm. - Highlights: • Absorption and emission cross sections of Ag/CdTe have been calculated. • Lasing parameters of these nanomaterials have been also estimated. • The energy transfer mechanism between Ag NPs and CdTe QDs was determined. • Our findings are promising candidate for photonic devices.

  16. II Peg: Spectroscopic Evidence for Multiple Starspot Temperatures

    Science.gov (United States)

    O'Neal, Douglas; Saar, Steven H.; Neff, James E. Neff

    We present spectroscopic evidence for multiple spot temperatures on the RS CVn star II Pegasi (HD 224085). We fit the strengths of the 7055 AAg and 8860 AAg TiO absorption bands in the spectrum of an active star using weighted sums of comparison spectra: the spectrum of an inactive K star to represent the non-spotted photosphere and the spectrum of an M star to represent the spots. We can thus independently measure starspot filling factor (fspot) and temperature (tspot). During 3/4 of a rotation of II Peg in Sept.-Oct. 1996, we measure fspot approximately constant at 55+/-5%. However, tspot varies from 3350 K to 3500 K. Since our method yields one derived tspot integrated over the visible hemisphere of the star, we present the results of simple models of a star with two distinct spot temperatures and compute the tspot we would derive in those cases. The changing tspot correlates with emission strengths of Hα and the Ca 2 infrared triplet, in the sense that cooler \\tspot accompanies weaker emission. We explore the consequences of these results for the physical properties of the spots on II Peg and for stellar surface structure in general.

  17. Spectroscopic fast neutron transmission imaging in a treaty verification setting

    Science.gov (United States)

    Ogren, K.; Nattress, J.; Jovanovic, I.

    2018-01-01

    Measurements of the geometric configuration of objects and their material composition are needed for nuclear treaty verification purposes. We experimentally demonstrate a simple method based on monoenergetic fast neutron transmission to realize crude imaging of the geometric configuration of special nuclear material, confirm its fissionable content, and obtain information on its approximate fissile mass. In the experiment, we used monoenergetic neutrons from D(d, n)3He and T(d, n)4He reactions and a linear array of liquid scintillation detectors to perform spectroscopic neutron imaging of up to 13.7 kg of highly enriched uranium in a spherical geometry. We also show an example of detection of material diversion and confirm the presence of fissionable material based on the measurement of high-energy prompt fission neutrons, including estimating the quantity of material from the comparison of measured and predicted fission neutron emission rate. The combination of crude imaging and fissionable material detection and quantification in a simple approach may be attractive in certain treaty verification scenarios.

  18. Detection and Monitoring of Neurotransmitters - a Spectroscopic Analysis

    Science.gov (United States)

    Manciu, Felicia; Lee, Kendall; Durrer, William; Bennet, Kevin

    2012-10-01

    In this work we demonstrate the capability of confocal Raman mapping spectroscopy for simultaneously and locally detecting important compounds in neuroscience such as dopamine, serotonin, and adenosine. The Raman results show shifting of the characteristic vibrations of the compounds, observations consistent with previous spectroscopic studies. Although some vibrations are common in these neurotransmitters, Raman mapping was achieved by detecting non-overlapping characteristic spectral signatures of the compounds, as follows: for dopamine the vibration attributed to C-O stretching, for serotonin the indole ring stretching vibration, and for adenosine the adenine ring vibrations. Without damage, dyeing, or preferential sample preparation, confocal Raman mapping provided positive detection of each neurotransmitter, allowing association of the high-resolution spectra with specific micro-scale image regions. Such information is particularly important for complex, heterogeneous samples, where modification of the chemical or physical composition can influence the neurotransmission processes. We also report an estimated dopamine diffusion coefficient two orders of magnitude smaller than that calculated by the flow-injection method.

  19. Spectroscopic Studies of Molecular Systems relevant in Astrobiology

    Science.gov (United States)

    Fornaro, Teresa

    2016-01-01

    In the Astrobiology context, the study of the physico-chemical interactions involving "building blocks of life" in plausible prebiotic and space-like conditions is fundamental to shed light on the processes that led to emergence of life on Earth as well as to molecular chemical evolution in space. In this PhD Thesis, such issues have been addressed both experimentally and computationally by employing vibrational spectroscopy, which has shown to be an effective tool to investigate the variety of intermolecular interactions that play a key role in self-assembling mechanisms of nucleic acid components and their binding to mineral surfaces. In particular, in order to dissect the contributions of the different interactions to the overall spectroscopic signals and shed light on the intricate experimental data, feasible computational protocols have been developed for the characterization of the spectroscopic properties of such complex systems. This study has been carried out through a multi-step strategy, starting the investigation from the spectroscopic properties of the isolated nucleobases, then studying the perturbation induced by the interaction with another molecule (molecular dimers), towards condensed phases like the molecular solid, up to the case of nucleic acid components adsorbed on minerals. A proper modeling of these weakly bound molecular systems has required, firstly, a validation of dispersion-corrected Density Functional Theory methods for simulating anharmonic vibrational properties. The isolated nucleobases and some of their dimers have been used as benchmark set for identifying a general, reliable and effective computational procedure based on fully anharmonic quantum mechanical computations of the vibrational wavenumbers and infrared intensities within the generalized second order vibrational perturbation theory (GVPT2) approach, combined with the cost-effective dispersion-corrected density functional B3LYP-D3, in conjunction with basis sets of

  20. Molecular spectroscopic study for suggested mechanism of chrome tanned leather.

    Science.gov (United States)

    Nashy, Elshahat H A; Osman, Osama; Mahmoud, Abdel Aziz; Ibrahim, Medhat

    2012-03-01

    Collagen represents the structural protein of the extracellular matrix, which gives strength of hides and/or skin under tanning process. Chrome tan is the most important tanning agent all over the world. The methods for production of leather evolved over several centuries as art and engineering with little understanding of the underlying science. The present work is devoted to suggest the most probable mechanistic action of chrome tan on hide proteins. First the affect of Cr upon hide protein is indicated by the studied mechanical properties. Then the spectroscopic characterization of the hide protein as well as chrome tanned leather was carried out with Horizontal Attenuated Total Reflection (HATR) FT-IR. The obtained results indicate how the chromium can attached with the active sites of collagen. Molecular modeling confirms that chromium can react with amino as well as carboxylate groups. Four schemes were obtained to describe the possible interactions of chrome tan with hide proteins. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Spectroscopic investigations on oxidized multi-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Anandhi, C. M. S.; Premkumar, S.; Asath, R. Mohamed; Mathavan, T.; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, N.M.S.S.V.N. College, Madurai-625 019, Tamil Nadu (India)

    2016-05-06

    The pristine multi-walled carbon nanotubes (MWCNTs) were oxidized by the ultrasonication process. The oxidized MWCNTs were characterized by the X-ray diffraction (XRD), ultraviolet–visible (UV-Vis) and Fourier transform -Raman (FT-Raman) spectroscopic techniques. The XRD analysis confirms that the oxidized MWCNTs exist in a hexagonal structure and the sharp XRD peak corresponds to the (002) Bragg’s reflection plane, which indicates that the MWCNTs have higher crystalline nature. The UV-Vis analysis confirms that the MWCNTs functionalized with the carboxylic acid. The red shift was observed corresponds to the D band in the Raman spectrum, which reveals that the reduced disordered graphitic structure of oxidized MWCNTs. The strong Raman peak was observed at 2563 cm{sup -1} corresponds to the overtone of the D band, which is the characteristic vibrational mode of oxidized MWCNTs. The carboxylic acid functionalization of MWCNTs enhances the dispersibility, which paves the way for potential applications in the field of biosensors and targeted drug delivery.

  2. Analytical Raman spectroscopic discrimination between yellow pigments of the Renaissance.

    Science.gov (United States)

    Edwards, Howell G M

    2011-10-01

    The Renaissance represented a major advance in painting techniques, subject matter, artistic style and the use of pigments and pigment mixtures. However, most pigments in general use were still mineral-based as most organic dyes were believed to be fugitive; the historical study of artists' palettes and recipes has assumed importance for the attribution of art works to the Renaissance period. Although the application of diagnostic elemental and molecular spectroscopic techniques play vital and complementary roles in the analysis of art works, elemental techniques alone cannot definitively provide the data needed for pigment identification. The advantages and limitations of Raman spectroscopy for the definitive diagnostic characterisation of yellow pigments that were in use during the Renaissance is demonstrated here in consideration of heavy metal oxides and sulphides; these data will be compared with those obtained from analyses of synthetic yellow pigments that were available during the eighteenth and nineteenth Centuries which could have been used in unrecorded restorations of Renaissance paintings. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Spectroscopic quantification of 5-hydroxymethylcytosine in genomic DNA.

    Science.gov (United States)

    Shahal, Tamar; Gilat, Noa; Michaeli, Yael; Redy-Keisar, Orit; Shabat, Doron; Ebenstein, Yuval

    2014-08-19

    5-Hydroxymethylcytosine (5hmC), a modified form of the DNA base cytosine, is an important epigenetic mark linked to regulation of gene expression in development, and tumorigenesis. We have developed a spectroscopic method for a global quantification of 5hmC in genomic DNA. The assay is performed within a multiwell plate, which allows simultaneous recording of up to 350 samples. Our quantification procedure of 5hmC is direct, simple, and rapid. It relies on a two-step protocol that consists of enzymatic glucosylation of 5hmC with an azide-modified glucose, followed by a "click reaction" with an alkyne-fluorescent tag. The fluorescence intensity recorded from the DNA sample is proportional to its 5hmC content and can be quantified by a simple plate reader measurement. This labeling technique is specific and highly sensitive, allowing detection of 5hmC down to 0.002% of the total nucleotides. Our results reveal significant variations in the 5hmC content obtained from different mouse tissues, in agreement with previously reported data.

  4. Characterisation of thin films by phase modulated spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Bhattacharyya, D.; Das, N.C.

    1998-07-01

    A wide variety of thin film coatings, deposited by different techniques and with potential applications in various important areas, have been characterised by the Phase Modulated Spectroscopic Ellipsometer, installed recently in the Spectroscopy Division, B.A.R.C. The Phase Modulated technique provides a faster and more accurate data acquisition process than the conventional ellipsometry. The measured Ellipsometry spectra are fitted with theoretical spectra generated assuming an appropriate model regarding the sample. The fittings have been done objectively by minimising the squared difference (χ 2 ) between the measured and calculated values of the ellipsometric parameters and thus accurate information have been derived regarding the thickness and optical constants (viz, the refractive index and extinction coefficient) of the different layers, the surface roughness and the inhomogeneities present in the layers. Measurements have been done on (i) ion-implanted Si-wafers to investigate the formation of SiC layers, (ii) phenyl- silane coating on glass to investigate the surface modifications achieved for better adsorption of rhodamine dye on glass, (iii) GaN films on quartz to investigate the formation of high quality GaN layers by sputtering of GaAs targets, (iv) Diamond-like-coating (DLC) samples prepared by Chemical Vapour Deposition (CVD) to investigate the optical properties which would ultimately lead to an accurate estimation of the ratio of sp 3 and sp 2 bonded carbon atoms in the films and (v) SS 304 under different surface treatments to investigate the growth of different passive films. (author)

  5. Ex vivo brain tumor analysis using spectroscopic optical coherence tomography

    Science.gov (United States)

    Lenz, Marcel; Krug, Robin; Welp, Hubert; Schmieder, Kirsten; Hofmann, Martin R.

    2016-03-01

    A big challenge during neurosurgeries is to distinguish between healthy tissue and cancerous tissue, but currently a suitable non-invasive real time imaging modality is not available. Optical Coherence Tomography (OCT) is a potential technique for such a modality. OCT has a penetration depth of 1-2 mm and a resolution of 1-15 μm which is sufficient to illustrate structural differences between healthy tissue and brain tumor. Therefore, we investigated gray and white matter of healthy central nervous system and meningioma samples with a Spectral Domain OCT System (Thorlabs Callisto). Additional OCT images were generated after paraffin embedding and after the samples were cut into 10 μm thin slices for histological investigation with a bright field microscope. All samples were stained with Hematoxylin and Eosin. In all cases B-scans and 3D images were made. Furthermore, a camera image of the investigated area was made by the built-in video camera of our OCT system. For orientation, the backsides of all samples were marked with blue ink. The structural differences between healthy tissue and meningioma samples were most pronounced directly after removal. After paraffin embedding these differences diminished. A correlation between OCT en face images and microscopy images can be seen. In order to increase contrast, post processing algorithms were applied. Hence we employed Spectroscopic OCT, pattern recognition algorithms and machine learning algorithms such as k-means Clustering and Principal Component Analysis.

  6. Metabolic networks in epilepsy by MR spectroscopic imaging.

    Science.gov (United States)

    Pan, J W; Spencer, D D; Kuzniecky, R; Duckrow, R B; Hetherington, H; Spencer, S S

    2012-12-01

    The concept of an epileptic network has long been suggested from both animal and human studies of epilepsy. Based on the common observation that the MR spectroscopic imaging measure of NAA/Cr is sensitive to neuronal function and injury, we use this parameter to assess for the presence of a metabolic network in mesial temporal lobe epilepsy (MTLE) patients. A multivariate factor analysis is performed with controls and MTLE patients, using NAA/Cr measures from 12 loci: the bilateral hippocampi, thalami, basal ganglia, and insula. The factor analysis determines which and to what extent these loci are metabolically covarying. We extract two independent factors that explain the data's variability in control and MTLE patients. In controls, these factors characterize a 'thalamic' and 'dominant subcortical' function. The MTLE patients also exhibit a 'thalamic' factor, in addition to a second factor involving the ipsilateral insula and bilateral basal ganglia. These data suggest that MTLE patients demonstrate a metabolic network that involves the thalami, also seen in controls. The MTLE patients also display a second set of metabolically covarying regions that may be a manifestation of the epileptic network that characterizes limbic seizure propagation. © 2012 John Wiley & Sons A/S.

  7. Electrochemical and spectroscopic measurements for stable nitroxyl radicals

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Kentaro; Iwasa, Shigeyuki; Iriyama, Jiro; Morioka, Yukiko; Suguro, Masahiro; Satoh, Masaharu [NEC Corporation, Tsukuba, Ibaraki (Japan). Fundamental and Environmental Research Laboratories; Cairns, Elton J. [Lawrence Berkeley National Laboratory, CA (United States). Environmental Energy Technologies Division

    2006-11-12

    A nitroxyl radical, 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO), is known to be oxidized electrochemically at 3.5V versus lithium [4,5]. Since this reaction is reversible in the aprotic electrolyte, we can use it as a cathode reaction in lithium rechargeable battery. Some nitroxyl radical compounds which have different structures have been prepared and their electrochemical behavior and spectroscopic properties have been studied. The electrochemical measurements in aprotic electrolyte revealed that most nitroxyl radical compounds show reversible redox behavior similar to that of TEMPO independent of their structures in the range of -0.15-0.20V versus Ag/Ag{sup +} (3.69-4.04V versus Li/Li{sup +}). The redox potentials for these materials were found to be predictable approximately by quantum calculations. Thus, various molecular designs tailored to desired redox potentials would be possible as active materials for lithium rechargeable batteries, and their specific capacities, mechanical properties and colors can be controlled within limits. (author)

  8. Preparation and Spectroscopic Characterization of Iron Doped Mullite

    Directory of Open Access Journals (Sweden)

    Iva Buljan

    2015-07-01

    Full Text Available A novel method for preparation of Fe2+/Fe3+ substituted mullite is described. Aluminosilicate gels are applied as precursors instead of crystalline aluminosilicates as used in other common syntheses. The process is composed of three stages. First, iron is introduced into a homogeneous aluminosilicate gel by ion exchange. The gel is converted to a mixture of mullite and amorphous silica in a 1263 K 3 h isothermal calcination in the the second stage. Finally, in order to obtain the nano-scale pure mullite phase the formed amorphous silica is removed by a dissolution in alkaline media. The components formed in various stages of the process are characterized by 57Fe Mössbauer and Fourier transform infra red spectroscopies, X-ray diffraction method and scanning electron microscopy. Spectroscopic and diffraction methods helped the identification of the mullite phase. Mössbauer measurements revealed the presence of both Fe2+ and Fe3+ states providing a chance for perspective catalytic application of the obtained Fe-mullite.

  9. Expression, purification and spectroscopic characterization of the Regulator complex

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, M.L.C.; Silva, A.L.S.; Camilotti, D.; Silva, C.A.; Sforca, M.L.; Smetana, J.H.C.; Zeri, A.C. [Laboratorio Nacional de Biociencias - LNBIO, Campinas, SP (Brazil); Ospina-Bedoya, M. [Universidad de Antioquia, Medellin (Colombia)

    2012-07-01

    Full text: The mammalian target of rapamycin (mTOR) signaling pathway integrates both intracellular and extracellular signals, serves as a central regulator of cell metabolism in humans and its deregulation is linked to diseases like cancer and diabetes. The small GTPases Rag are mediators of signaling by amino acid (leucine). These GT-Pases are anchored on the surface of the lysosome through an interaction with a complex of three proteins, p18, MP1 and p14, called Ragulator. The p18 protein is responsible for interaction with the lysosomal membrane through its N terminal post translational modification. The objective of this project is to study the interaction of p18 and other components of the Ragulator complex. The p18 protein was expressed in inclusion bodies, which were isolated and solubilized in urea. p18 was renatured with its partners MP1/p14 and this complex, the Ragulator, was subjected to spectroscopic characterization using circular dichroism and dynamic light scattering. (author)

  10. Preliminary Spectroscopic Measurements for a Gallium Electromagnetic (GEM) Thruster

    Science.gov (United States)

    Thomas, Robert E.; Burton, Rodney L.; Glumac, Nick G.; Polzin, Kurt A.

    2007-01-01

    As a propellant option for electromagnetic thrusters, liquid ,gallium appears to have several advantages relative to other propellants. The merits of using gallium in an electromagnetic thruster (EMT) are discussed and estimates of discharge current levels and mass flow rates yielding efficient operation are given. The gallium atomic weight of 70 predicts high efficiency in the 1500-2000 s specific impulse range, making it ideal for higher-thrust, near-Earth missions. A spatially and temporally broad spectroscopic survey in the 220-520 nm range is used to determine which species are present in the plasma and estimate electron temperature. The spectra show that neutral, singly, and doubly ionized gallium species are present in a 20 J, 1.8 kA (peak) are discharge. With graphite present on the insulator to facilitate breakdown, singly and doubly ionized carbon atoms are also present, and emission is observed from molecular carbon (CZ) radicals. A determination of the electron temperature was attempted using relative emission line data, and while the spatially and temporally averaged, spectra don't fit well to single temperatures, the data and presence of doubly ionized gallium are consistent with distributions in the 1-3 eV range.

  11. Spectroscopic and electrochemical characterization of nanostructured optically transparent carbon electrodes.

    Science.gov (United States)

    Benavidez, Tomás E; Garcia, Carlos D

    2013-07-01

    The present paper describes the results related to the optical and electrochemical characterization of thin carbon films fabricated by spin coating and pyrolysis of AZ P4330-RS photoresist. The goal of this paper is to provide comprehensive information allowing for the rational selection of the conditions to fabricate optically transparent carbon electrodes (OTCE) with specific electrooptical properties. According to our results, these electrodes could be appropriate choices as electrochemical transducers to monitor electrophoretic separations. At the core of this manuscript is the development and critical evaluation of a new optical model to calculate the thickness of the OTCE by variable angle spectroscopic ellipsometry. Such data were complemented with topography and roughness (obtained by atomic force microscopy), electrochemical properties (obtained by cyclic voltammetry), electrical properties (obtained by electrochemical impedance spectroscopy), and structural composition (obtained by Raman spectroscopy). Although the described OTCE were used as substrates to investigate the effect of electrode potential on the real-time adsorption of proteins by ellipsometry, these results could enable the development of other biosensors that can be then integrated into various CE platforms. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. The limit of detection for explosives in spectroscopic differential reflectometry

    Science.gov (United States)

    Dubroca, Thierry; Vishwanathan, Karthik; Hummel, Rolf E.

    2011-05-01

    In the wake of recent terrorist attacks, such as the 2008 Mumbai hotel explosion or the December 25th 2009 "underwear bomber", our group has developed a technique (US patent #7368292) to apply differential reflection spectroscopy to detect traces of explosives. Briefly, light (200-500 nm) is shone on a surface such as a piece of luggage at an airport. Upon reflection, the light is collected with a spectrometer combined with a CCD camera. A computer processes the data and produces in turn a differential reflection spectrum involving two adjacent areas of the surface. This differential technique is highly sensitive and provides spectroscopic data of explosives. As an example, 2,4,6, trinitrotoluene (TNT) displays strong and distinct features in differential reflectograms near 420 nm. Similar, but distinctly different features are observed for other explosives. One of the most important criteria for explosive detection techniques is the limit of detection. This limit is defined as the amount of explosive material necessary to produce a signal to noise ratio of three. We present here, a method to evaluate the limit of detection of our technique. Finally, we present our sample preparation method and experimental set-up specifically developed to measure the limit of detection for our technology. This results in a limit ranging from 100 nano-grams to 50 micro-grams depending on the method and the set-up parameters used, such as the detector-sample distance.

  13. A spectroscopic study of uranium species formed in chloride melts

    International Nuclear Information System (INIS)

    Volkovich, Vladimir A.; Bhatt, Anand I.; May, Iain; Griffiths, Trevor R.; Thied, Robert C.

    2002-01-01

    The chlorination of uranium metal or uranium oxides in chloride melts offers an acceptable process for the head-end of pyrochemical reprocessing of spent nuclear fuels. The reactions of uranium metal and ceramic uranium dioxide with chlorine and with hydrogen chloride were studied in the alkali metal chloride melts, NaCl-KCl at 973K, NaCl-CsCl between 873 and 923K and LiCl-KCl at 873K. The uranium species formed therein were characterized from their electronic absorption spectra measured in situ. The kinetic parameters of the reactions depend on melt composition, temperature and chlorinating agent used. The reaction of uranium dioxide with oxygen in the presence of alkali metal chlorides results in the formation of alkali metal uranates. A spectroscopic study, between 723 and 973K, on their formation and their solutions was undertaken in LiCl, LiCl-KCl eutectic and NaCl-CsCl eutectic melts. The dissolution of uranium dioxide in LiCl-KCl eutectic at 923K containing added aluminium trichloride in the presence of oxygen has also been investigated. In this case, the reaction leads to the formation of uranyl chloride species. (author)

  14. Spectroscopic analysis of biologically synthesized silver nanoparticles under clinorotation

    Science.gov (United States)

    Jagtap, Sagar; Vidyasagar, Pandit; Ghemud, Vipul; Dixit, Jyotsana

    Nanoparticles are one of the hot topics of research due to their size dependent optical, electrical and magnetic properties & their anti-bacterial and anti-fungal nature. Synthesis of nano particles can be done by various physical and chemical methods. However, Biosynthesis of nanoparticles is environment friendly, can take place around room temperature, and require little intervention or input of energy. In the present study, the synthesis of silver nanoparticles (AgNPs) using bacteria and the effect of clinorotation on rate of synthesis is discussed. The freshly grown bacterial isolate was inoculated in to 250-ml Erlenmeyer flask containing 50 ml sterile nutrient broth (LB). The cultured flasks were incubated in a shaker at 120 rpm for 24 h at 370C. Culture was centrifuged at 10,000 rpm for 10 min. The supernatant was used for carrying extracellular production of silver nanoparticles by mixing it with 5mM AgNO3 solution. The above solution was clinorotated at 2 rpm for 24 h. The synthesis was carried out at 60oC. Visual observation was conducted periodically to check for the nanoparticles formation in normal gravity as well as under clinorotation. UV-visible spectroscopic analysis showed that rate of synthesis was faster in case of clinorotated sample than control. Further, the results of FTIR and XRD characterization will be discussed.

  15. Position paper on standardization

    International Nuclear Information System (INIS)

    1991-04-01

    The ''NPOC Strategic Plan for Building New Nuclear Plants'' creates a framework within which new standardized nuclear plants may be built. The Strategic Plan is an expression of the nuclear energy industry's serious intent to create the necessary conditions for new plant construction and operation. One of the key elements of the Strategic Plan is a comprehensive industry commitment to standardization: through design certification, combined license, first-of-a-kind engineering, construction, operation and maintenance of nuclear power plants. The NPOC plan proposes four stages of standardization in advanced light water reactors (ALWRs). The first stage is established by the ALWR Utility Requirements Document which specifies owner/operator requirements at a functional level covering all elements of plant design and construction, and many aspects of operations and maintenance. The second stage of standardization is that achieved in the NRC design certification. This certification level includes requirements, design criteria and bases, functional descriptions and performance requirements for systems to assure plant safety. The third stage of standardization, commercial standardization, carries the design to a level of completion beyond that required for design certification to enable the industry to achieve potential increases in efficiency and economy. The final stage of standardization is enhanced standardization beyond design. A standardized approach is being developed in construction practices, operating, maintenance training, and procurement practices. This comprehensive standardization program enables the NRC to proceed with design certification with the confidence that standardization beyond the regulations will be achieved. This confidence should answer the question of design detail required for design certification, and demonstrate that the NRC should require no further regulatory review beyond that required by 10 CFR Part 52

  16. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...

  17. 77 FR 43542 - Cost Accounting Standards: Cost Accounting Standards 412 and 413-Cost Accounting Standards...

    Science.gov (United States)

    2012-07-25

    ... Accounting Standards: Cost Accounting Standards 412 and 413--Cost Accounting Standards Pension Harmonization Rule AGENCY: Cost Accounting Standards Board, Office of Federal Procurement Policy, Office of... Policy (OFPP), Cost Accounting Standards Board (Board), is publishing technical corrections to the final...

  18. State Skill Standards: Photography

    Science.gov (United States)

    Howell, Frederick; Reed, Loretta; Jensen, Capra; Robison, Gary; Taylor, Susan; Pavesich, Christine

    2007-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide skill standards for all content areas in career and technical education. The standards in this document are for photography programs and are designed to clearly state what the student should know and be able to do upon completion of an advanced high-school program.…

  19. Standards and Administration.

    Science.gov (United States)

    Gross, S. P.

    1978-01-01

    Presents a literature review of water quality standards and administration, covering publications of 1976-77. Consideration is given to municipal facilities, National Pollutant Discharge Elimination Systems, regional and international water quality management, and effluent standards. A list of 99 references is also presented. (HM)

  20. How many standards?

    DEFF Research Database (Denmark)

    Maegaard, Marie

    2009-01-01

    Discussions of standardisation and standard languages has a long history in linguistics. Tore Kristiansen has contributed to these discussions in various ways, and in this chapter I will focus on his claim that young Danes operate with two standards, one for the media and one for the school...

  1. Standard Weights and Measures

    Indian Academy of Sciences (India)

    The mass standard, represented by the proto- type kilogram, is the only remaining artifact, but there are promising proposals to replace that in the near future. Ever since humans started living in community settle- ments, day to day activities have required the adoption of a set of standards for weights and measures. For ex-.

  2. Teachers Voices Interpreting Standards

    Directory of Open Access Journals (Sweden)

    Leo C. Rigsby

    2003-11-01

    Full Text Available The State of Virginia has adopted state-mandated testing that aims to raise the standards of performance for children in our schools in a manner that assigns accountability to schools and to teachers. In this paper we argue that the conditions under which the standards were created and the testing implemented undermine the professionalism of teachers. We believe this result has the further consequence of compromising the critical thinking and learning processes of children. We argue this has happened because teachers’ views and experiences have driven neither the setting of standards nor the assessment of their achievement. We use data from essays by teachers in an innovative masters program to compare teachers’ experiences involving the Virginia Standards of Learning with ideal standards for professional development adopted by the National Board for Professional Teaching Standards. We argue that there are serious negative consequences of the failure to include dialogue with K-12 teachers in setting standards and especially in the creation of assessments to measure performances relative to the standards. We believe the most successful, honest, and morally defensible processes must be built on the experience and wisdom of classroom teachers.

  3. Revisiting Professional Teacher Standards

    Science.gov (United States)

    Watson, Amanda

    2016-01-01

    The Australian Society for Music Education's (ASME) involvement in the development of professional standards for music educators was a significant and active research time in the history of the Society. As ASME celebrates its golden jubilee, it is appropriate to revisit that history and consider the future prospects of subject-specific standards.…

  4. Weston Standard battery

    CERN Multimedia

    This is a Weston AOIP standard battery with its calibration certificate (1956). Inside, the glassware forms an "H". Its name comes from the British physicist Edward Weston. A standard is the materialization of a given quantity whose value is known with great accuracy.

  5. A case of standardization?

    DEFF Research Database (Denmark)

    Rod, Morten Hulvej; Høybye, Mette Terp

    2016-01-01

    Guidelines are increasingly used in an effort to standardize and systematize health practices at the local level and to promote evidence-based practice. The implementation of guidelines frequently faces problems, however, and standardization processes may in general have other outcomes than...... the ones envisioned by the makers of standards. In 2012, the Danish National Health Authorities introduced a set of health promotion guidelines that were meant to guide the decision making and priority setting of Denmark's 98 local governments. The guidelines provided recommendations for health promotion...... and standardization. It remains an open question whether or not the guidelines lead to more standardized policies and interventions, but we suggest that the guidelines promote a risk factor-oriented approach as the dominant frame for knowledge, reasoning, decision making and priority setting in health promotion. We...

  6. Evaluating Living Standard Indicators

    Directory of Open Access Journals (Sweden)

    Birčiaková Naďa

    2015-09-01

    Full Text Available This paper deals with the evaluation of selected available indicators of living standards, divided into three groups, namely economic, environmental, and social. We have selected six countries of the European Union for analysis: Bulgaria, the Czech Republic, Hungary, Luxembourg, France, and Great Britain. The aim of this paper is to evaluate indicators measuring living standards and suggest the most important factors which should be included in the final measurement. We have tried to determine what factors influence each indicator and what factors affect living standards. We have chosen regression analysis as our main method. From the study of factors, we can deduce their impact on living standards, and thus the value of indicators of living standards. Indicators with a high degree of reliability include the following factors: size and density of population, health care and spending on education. Emissions of carbon dioxide in the atmosphere also have a certain lower degree of reliability.

  7. High-Resolution Calibration of the SDSS/SEGUE Spectroscopic Analysis Pipeline

    Science.gov (United States)

    Sivarani, T.; Beers, T. C.; Lee, Y.; Krugler, J.; Wilhelm, R.; Allende Prieto, C.; Sneden, C.; Lambert, D. L.; Shetrone, M.; Johnson, J.; Ivans, I.; Rockosi, C.; Lai, D.; Morrison, H.; Aoki, W.

    2006-12-01

    We present a discussion of efforts to obtain external validation of the estimated atmospheric parameters (Teff, log g, [Fe/H]) obtained from medium-resolution (R = 2000) SDSS spectroscopy and ugriz photometry, which are being employed for both the completed SDSS-I and the ongoing SEGUE survey. The SDSS/SEGUE spectroscopic pipeline makes use of a number of methods for the estimation of each parameter, with estimated internal errors on the order of σ(Teff) = 150 K, σ(log g) = 0.4 dex, and σ([Fe/H]) = 0.3 dex. Over the course of the past two years, we have obtained over 100 high-resolution optical spectra of SDSS/SEGUE stars using the HET, KECK and SUBARU telescopes. For the KECK/HIRES spectra, which have R = 40000, we have performed standard high-resolution analyses to estimate the stellar parameters. For the HET and KECK-ESI data, which have R = 15000 and R = 5000, respectively, we have performed synthetic spectra matching in order to to estimate the stellar parameters. We find that the derived stellar parameters agree well with the SDSS/SEGUE pipeline estimates for the temperature range 5000 K 6500 K. The main reason for these offsets appears to arise due to varying microturbulence, for which the medium-resolution SDSS spectra are not sensitive. We also have performed external checks on pipline radial velocities. We find that the errors in radial velocities are on the order of 7 km/s for stars, which is at the expected level.

  8. Ab initio structural and spectroscopic study of HPS{sup x} and HSP{sup x} (x = 0,+1,−1) in the gas phase

    Energy Technology Data Exchange (ETDEWEB)

    Yaghlane, Saida Ben [Laboratoire de Spectroscopie Atomique, Moléculaire et Applications – LSAMA, Université de Tunis, Tunis (Tunisia); Cotton, C. Eric; Francisco, Joseph S., E-mail: francisc@purdue.edu, E-mail: hochlaf@univ-mlv.fr [Department of Chemistry and Department of Earth and Atmospheric Science, Purdue University, West Lafayette, Indiana 49707 (United States); Linguerri, Roberto; Hochlaf, Majdi, E-mail: francisc@purdue.edu, E-mail: hochlaf@univ-mlv.fr [Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, Université Paris-Est, 5 bd Descartes, 77454 Marne-la-Vallée (France)

    2013-11-07

    Accurate ab initio computations of structural and spectroscopic parameters for the HPS/HSP molecules and corresponding cations and anions have been performed. For the electronic structure computations, standard and explicitly correlated coupled cluster techniques in conjunction with large basis sets have been adopted. In particular, we present equilibrium geometries, rotational constants, harmonic vibrational frequencies, adiabatic ionization energies, electron affinities, and, for the neutral species, singlet-triplet relative energies. Besides, the full-dimensional potential energy surfaces (PESs) for HPS{sup x} and HSP{sup x} (x = −1,0,1) systems have been generated at the standard coupled cluster level with a basis set of augmented quintuple-zeta quality. By applying perturbation theory to the calculated PESs, an extended set of spectroscopic constants, including τ, first-order centrifugal distortion and anharmonic vibrational constants has been obtained. In addition, the potentials have been used in a variational approach to deduce the whole pattern of vibrational levels up to 4000 cm{sup −1} above the minima of the corresponding PESs.

  9. Monitoring, controlling and safeguarding radiochemical streams at spent fuel reprocessing facilities with optical and gamma-ray spectroscopic methods

    International Nuclear Information System (INIS)

    Schwantes, J.M.; Bryan, S.A.; Orton, C.R.; Levitskaia, T.G.; Fraga, C.G.

    2013-01-01

    The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-usable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MCA) at these facilities require time-consuming and resource intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify off-normal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop

  10. Standard dilution analysis.

    Science.gov (United States)

    Jones, Willis B; Donati, George L; Calloway, Clifton P; Jones, Bradley T

    2015-02-17

    Standard dilution analysis (SDA) is a novel calibration method that may be applied to most instrumental techniques that will accept liquid samples and are capable of monitoring two wavelengths simultaneously. It combines the traditional methods of standard additions and internal standards. Therefore, it simultaneously corrects for matrix effects and for fluctuations due to changes in sample size, orientation, or instrumental parameters. SDA requires only 200 s per sample with inductively coupled plasma optical emission spectrometry (ICP OES). Neither the preparation of a series of standard solutions nor the construction of a universal calibration graph is required. The analysis is performed by combining two solutions in a single container: the first containing 50% sample and 50% standard mixture; the second containing 50% sample and 50% solvent. Data are collected in real time as the first solution is diluted by the second one. The results are used to prepare a plot of the analyte-to-internal standard signal ratio on the y-axis versus the inverse of the internal standard concentration on the x-axis. The analyte concentration in the sample is determined from the ratio of the slope and intercept of that plot. The method has been applied to the determination of FD&C dye Blue No. 1 in mouthwash by molecular absorption spectrometry and to the determination of eight metals in mouthwash, wine, cola, nitric acid, and water by ICP OES. Both the accuracy and precision for SDA are better than those observed for the external calibration, standard additions, and internal standard methods using ICP OES.

  11. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1993-01-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes

  12. Wireless installation standard

    International Nuclear Information System (INIS)

    Lim, Hwang Bin

    2007-12-01

    This is divided six parts which are radio regulation law on securing of radio resource, use of radio resource, protection of radio resource, radio regulation enforcement ordinance with securing, distribution and assignment of radio regulation, radio regulation enforcement regulation on utility of radio resource and technical qualification examination, a wireless installation regulation of technique standard and safety facility standard, radio regulation such as certification regulation of information communicative machines and regulation of radio station on compliance of signal security, radio equipment in radio station, standard frequency station and emergency communication.

  13. Detection of carotenoids in psychrotrophic bacteria by spectroscopic approach

    Directory of Open Access Journals (Sweden)

    Kirti Kushwaha

    2014-12-01

    Full Text Available The combination of Raman and Infrared spectroscopic signatures were used to find the different vibrational modes of individual carotenoid as their spectral fingerprint. Both have been previously demonstrated to be highly useful methodology for the identification and/or typing of microorganisms. In this study, we set out to evaluate whether these technologies could be applied to detect the presence of carotenoids in psychrotrophic bacterial isolates. FTIR and Raman spectra of four psychrotrophic bacteria viz. Kocuria rosea, K. turfanensis, Sanguibacter suarezii and Planococcus maritimus were examined during the investigation. FTIR spectra bands at 1653-1661cm-1 in different samples were assigned as part of chlorophyll, 1424-1426 cm-1 as -C-H- (CH2 bending vibration from methylene of carotenoids or lycopene, 1366-1367 cm-1 band as the -ionone ring of β-carotene due to the C-H, (–CH3 symmetrical bending. Interestingly, Raman spectra revealed intense Raman bands in the range of 1511-1530, 1153-1159 and 1003-1010 cm-1 representing bacterial carotenoids. We hypothesize the biosynthesis of carotenoid as adaptive strategy to cope up inhospitable cold environments of Leh and Ladakh. The strong, scattering bands by different isolates attributable to ν(C=C phase stretching, ν(C-C and δ(C-CH3 methyl components systems, which could be probably membrane-associated C50 carotenoids. Their high intensities are due to resonance enhancement. It can be concluded that Raman spectroscopy is a sensitive and convenient detection tool for typing of the bacterial biomarkers with less time consumption.

  14. NMR, MRI, and spectroscopic MRI in inhomogeneous fields

    Science.gov (United States)

    Demas, Vasiliki; Pines, Alexander; Martin, Rachel W; Franck, John; Reimer, Jeffrey A

    2013-12-24

    A method for locally creating effectively homogeneous or "clean" magnetic field gradients (of high uniformity) for imaging (with NMR, MRI, or spectroscopic MRI) both in in-situ and ex-situ systems with high degrees of inhomogeneous field strength. THe method of imaging comprises: a) providing a functional approximation of an inhomogeneous static magnetic field strength B.sub.0({right arrow over (r)}) at a spatial position {right arrow over (r)}; b) providing a temporal functional approximation of {right arrow over (G)}.sub.shim(t) with i basis functions and j variables for each basis function, resulting in v.sub.ij variables; c) providing a measured value .OMEGA., which is an temporally accumulated dephasing due to the inhomogeneities of B.sub.0({right arrow over(r)}); and d) minimizing a difference in the local dephasing angle .phi.({right arrow over (r)},t)=.gamma..intg..sub.0.sup.t{square root over (|{right arrow over (B)}.sub.1({right arrow over (r)},t')|.sup.2+({right arrow over (r)}{right arrow over (G)}.sub.shimG.sub.shim(t')+.parallel.{right arrow over (B)}.sub.0({right arrow over (r)}).parallel..DELTA..omega.({right arrow over (r)},t'/.gamma/).sup.2)}dt'-.OMEGA. by varying the v.sub.ij variables to form a set of minimized v.sub.ij variables. The method requires calibration of the static fields prior to minimization, but may thereafter be implemented without such calibration, may be used in open or closed systems, and potentially portable systems.

  15. Target allocation yields for massively multiplexed spectroscopic surveys with fibers

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Will [Australian Astron. Observ.; Smedley, Scott [Australian Astron. Observ.; Gillingham, Peter [Australian Astron. Observ.; Forero-Romero, Jaime E. [Andes U., Bogota; Jouvel, Stephanie [ICE, Bellaterra; Nord, Brian [Fermilab

    2014-08-05

    We present Simulated Annealing fiber-to-target allocation simulations for the proposed DESI and 4MOST massively multiplexed spectroscopic surveys, and for both Poisson and realistically clustered mock target samples. We simulate both Echidna and theta-phi actuator designs, including the restrictions caused by the physical actuator characteristics during repositioning. For DESI, with theta-phi actuators, used in 5 passes over the sky for a mock ELG/LRG/QSO sample, with matched fiber and target densities, a total target allocation yield of 89.3% was achieved, but only 83.7% for the high-priority Ly-alpha QSOs. If Echidna actuators are used with the same pitch and number of passes, the yield increases by 5.7% and 16% respectively. Echidna also allows a factor-of-two increase in the number of close Ly-alpha QSO pairs that can be observed. Echidna spine tilt causes a variable loss of throughput, with average loss being the same as the loss at the rms tilt. With a natural tilt minimization scheme, we find an rms tilt always close to 0.58 x maximum. There is an additional but much smaller defocus loss, equivalent to an average defocus of 30microns. These tilt losses offset the gains in yield for Echidna, but because the survey strategy is driven by the higher priority targets, a clear survey speed advantage remains. For 4MOST, high and low latitude sample mock catalogs were supplied by the 4MOST team, and allocations were carried out with the proposed Echidna-based positioner geometry. At high latitudes, the resulting target completeness was 85.3% for LR targets and 78.9% for HR targets. At low latitude, the target completeness was 93.9% for LR targets and 71.2% for HR targets.

  16. Linking vegetation structure, function and physiology through spectroscopic remote sensing

    Science.gov (United States)

    Serbin, S.; Singh, A.; Couture, J. J.; Shiklomanov, A. N.; Rogers, A.; Desai, A. R.; Kruger, E. L.; Townsend, P. A.

    2015-12-01

    Terrestrial ecosystem process models require detailed information on ecosystem states and canopy properties to properly simulate the fluxes of carbon (C), water and energy from the land to the atmosphere and assess the vulnerability of ecosystems to perturbations. Current models fail to adequately capture the magnitude, spatial variation, and seasonality of terrestrial C uptake and storage, leading to significant uncertainties in the size and fate of the terrestrial C sink. By and large, these parameter and process uncertainties arise from inadequate spatial and temporal representation of plant traits, vegetation structure, and functioning. With increases in computational power and changes to model architecture and approaches, it is now possible for models to leverage detailed, data rich and spatially explicit descriptions of ecosystems to inform parameter distributions and trait tradeoffs. In this regard, spectroscopy and imaging spectroscopy data have been shown to be invaluable observational datasets to capture broad-scale spatial and, eventually, temporal dynamics in important vegetation properties. We illustrate the linkage of plant traits and spectral observations to supply key data constraints for model parameterization. These constraints can come either in the form of the raw spectroscopic data (reflectance, absorbtance) or physiological traits derived from spectroscopy. In this presentation we highlight our ongoing work to build ecological scaling relationships between critical vegetation characteristics and optical properties across diverse and complex canopies, including temperate broadleaf and conifer forests, Mediterranean vegetation, Arctic systems, and agriculture. We focus on work at the leaf, stand, and landscape scales, illustrating the importance of capturing the underlying variability in a range of parameters (including vertical variation within canopies) to enable more efficient scaling of traits related to functional diversity of ecosystems.

  17. Spectroscopic markers of the TR quaternary transition in human hemoglobin.

    Science.gov (United States)

    Schirò, Giorgio; Cammarata, Marco; Levantino, Matteo; Cupane, Antonio

    2005-04-01

    In this work, we use a sol-gel protocol to trap and compare the R and T quaternary states of both the deoxygenated (deoxyHb) and carbonmonoxide (HbCO) derivatives of human hemoglobin. The near infrared optical absorption band III and the infrared CO stretching band are used to detect the effect of quaternary structure on the spectral properties of deoxyHb and HbCO; comparison with myoglobin allows for an assessment of tertiary and quaternary contributions to the measured band shifts. The RT transition is shown to cause a blue shift of the band III by approximately 35 cm(-1) for deoxyHb and a red shift of the CO stretching band by only approximately 0.3 cm(-1) for HbCO. This clearly shows that quaternary structure changes are transmitted to the heme pocket and that effects on deoxyHb are much larger than on HbCO, at least as far as the band energies are concerned. Experiments performed in the ample temperature interval of 300-10K show that the above quaternary structure effects are "static" and do not influence the dynamic properties of the heme pocket, at least as probed by the temperature dependence of band III and of the CO stretching band. The availability of quaternary structure sensitive spectroscopic markers and the quantitative measurement of the quaternary structure contribution to band shifts will be of considerable help in the analysis of flash-photolysis experiments on hemoglobin. Moreover, it will enable one to characterize the dynamic properties of functionally relevant hemoglobin intermediates and to study the kinetics of both the T-->R and R-->T quaternary transitions through time-resolved spectroscopy.

  18. Spectroscopic detection and mapping of vinyl cyanide on Titan

    Science.gov (United States)

    Cordiner, Martin; Yukiko Palmer, Maureen; Lai, James; Nixon, Conor A.; Teanby, Nicholas; Charnley, Steven B.; Vuitton, Veronique; Kisiel, Zbigniew; Irwin, Patrick; Molter, Ned; Mumma, Michael J.

    2017-10-01

    The first spectroscopic detection of vinyl cyanide (otherwise known as acrylonitrile; C2H3CN) on Titan was obtained by Palmer et al. (2017), based on three rotational emission lines observed with ALMA at millimeter wavelengths (in receiver band 6). The astrobiological significance of this detection was highlighted due to the theorized ability of C2H3CN molecules to combine into cell membrane-like structures under the cold conditions found in Titan's hydrocarbon lakes. Here we report the detection of three additional C2H3CN transitions at higher frequencies (from ALMA band 7 flux calibration data). We present the first emission maps for this gas on Titan, and compare the molecular distribution with that of other nitriles observed with ALMA including HC3N, CH3CN, C2H5CN and HNC. The molecular abundance patterns are interpreted based on our understanding of Titan's high-altitude photochemistry and time-variable global circulation. Similar to the short-lived HC3N molecule, vinyl cyanide is found to be most abundant in the vicinity of the southern (winter) pole, whereas the longer-lived CH3CN is more concentrated in the north. The vertical abundance profile of C2H3CN (from radiative transfer modeling), as well as its latitudinal distribution, are consistent with a short photochemical lifetime for this species. Complementary results from our more recent (2017) nitrile mapping studies at higher spatial resolution will also be discussed.REFERENCES:Palmer, M. Y., Cordiner, M. A., Nixon, C. A. et al. "ALMA detection and astrobiological potential of vinyl cyanide on Titan", Sci. Adv. 2017, 3, e1700022

  19. ETHYL CYANIDE ON TITAN: SPECTROSCOPIC DETECTION AND MAPPING USING ALMA

    Energy Technology Data Exchange (ETDEWEB)

    Cordiner, M. A.; Palmer, M. Y.; Nixon, C. A.; Charnley, S. B.; Mumma, M. J.; Serigano, J. [NASA Goddard Space Flight Center, 8800 Greenbelt Road, Greenbelt, MD 20771 (United States); Irwin, P. G. J. [Atmospheric, Oceanic and Planetary Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU (United Kingdom); Teanby, N. A. [School of Earth Sciences, University of Bristol, Wills Memorial Building, Queen’s Road, Bristol, BS8 1RJ (United Kingdom); Kisiel, Z. [Institute of Physics, Polish Academy of Sciences, Al. Lotnikøw 32/46, 02-668 Warszawa (Poland); Kuan, Y.-J.; Chuang, Y.-L. [National Taiwan Normal University, Taipei 116, Taiwan (China); Wang, K.-S., E-mail: martin.cordiner@nasa.gov [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 106, Taiwan (China)

    2015-02-10

    We report the first spectroscopic detection of ethyl cyanide (C{sub 2}H{sub 5}CN) in Titan’s atmosphere, obtained using spectrally and spatially resolved observations of multiple emission lines with the Atacama Large Millimeter/submillimeter Array (ALMA). The presence of C{sub 2}H{sub 5}CN in Titan’s ionosphere was previously inferred from Cassini ion mass spectrometry measurements of C{sub 2}H{sub 5}CNH{sup +}. Here we report the detection of 27 rotational lines from C{sub 2}H{sub 5}CN (in 19 separate emission features detected at >3σ confidence) in the frequency range 222–241 GHz. Simultaneous detections of multiple emission lines from HC{sub 3}N, CH{sub 3}CN, and CH{sub 3}CCH were also obtained. In contrast to HC{sub 3}N, CH{sub 3}CN, and CH{sub 3}CCH, which peak in Titan’s northern (spring) hemisphere, the emission from C{sub 2}H{sub 5}CN is found to be concentrated in the southern (autumn) hemisphere, suggesting a distinctly different chemistry for this species, consistent with a relatively short chemical lifetime for C{sub 2}H{sub 5}CN. Radiative transfer models show that C{sub 2}H{sub 5}CN is most concentrated at altitudes ≳200 km, suggesting production predominantly in the stratosphere and above. Vertical column densities are found to be in the range (1–5) × 10{sup 14} cm{sup −2}.

  20. Nuclear Spectroscopic Telescope Array (NuSTAR) Mission

    Science.gov (United States)

    Kim, Yunjin; Willis, Jason; Dodd, Suzanne; Harrison, Fiona; Forster, Karl; Craig, William; Bester, Manfred; Oberg, David

    2013-01-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) is a National Aeronautics and Space Administration (NASA) Small Explorer mission that carried the first focusing hard X-ray (6-79 keV) telescope into orbit. It was launched on a Pegasus rocket into a low-inclination Earth orbit on June 13, 2012, from Reagan Test Site, Kwajalein Atoll. NuSTAR will carry out a two-year primary science mission. The NuSTAR observatory is composed of the X-ray instrument and the spacecraft. The NuSTAR spacecraft is three-axis stabilized with a single articulating solar array based on Orbital Sciences Corporation's LEOStar-2 design. The NuSTAR science instrument consists of two co-aligned grazing incidence optics focusing on to two shielded solid state CdZnTe pixel detectors. The instrument was launched in a compact, stowed configuration, and after launch, a 10-meter mast was deployed to achieve a focal length of 10.15 m. The NuSTAR instrument provides sub-arcminute imaging with excellent spectral resolution over a 12-arcminute field of view. The NuSTAR observatory will be operated out of the Mission Operations Center (MOC) at UC Berkeley. Most science targets will be viewed for a week or more. The science data will be transferred from the UC Berkeley MOC to a Science Operations Center (SOC) located at the California Institute of Technology (Caltech). In this paper, we will describe the mission architecture, the technical challenges during the development phase, and the post-launch activities.

  1. Organic Scintillation Detectors for Spectroscopic Radiation Portal Monitors

    Science.gov (United States)

    Paff, Marc Gerrit

    Thousands of radiation portal monitors have been deployed worldwide to detect and deter the smuggling of nuclear and radiological materials that could be used in nefarious acts. Radiation portal monitors are often installed at bottlenecks where large amounts of people or goods must traverse. Examples of use include scanning cargo containers at shipping ports, vehicles at border crossings, and people at high profile functions and events. Traditional radiation portal monitors contain separate detectors for passively measuring neutron and gamma ray count rates. 3He tubes embedded in polyethylene and slabs of plastic scintillators are the most common detector materials used in radiation portal monitors. The radiation portal monitor alarm mechanism relies on measuring radiation count rates above user defined alarm thresholds. These alarm thresholds are set above natural background count rates. Minimizing false alarms caused by natural background and maximizing sensitivity to weakly emitting threat sources must be balanced when setting these alarm thresholds. Current radiation portal monitor designs suffer from frequent nuisance radiation alarms. These radiation nuisance alarms are most frequently caused by shipments of large quantities of naturally occurring radioactive material containing cargo, like kitty litter, as well as by humans who have recently undergone a nuclear medicine procedure, particularly 99mTc treatments. Current radiation portal monitors typically lack spectroscopic capabilities, so nuisance alarms must be screened out in time-intensive secondary inspections with handheld radiation detectors. Radiation portal monitors using organic liquid scintillation detectors were designed, built, and tested. A number of algorithms were developed to perform on-the-fly radionuclide identification of single and combination radiation sources moving past the portal monitor at speeds up to 2.2 m/s. The portal monitor designs were tested extensively with a variety of

  2. Performance of The Far Ultraviolet Spectroscopic Explorer Mirror Assemblies

    Science.gov (United States)

    Ohi, Raymond G.; Barkhouser, Robert H.; Conard, Steven J.; Friedman, Scott D.; Hampton, Jeffery; Moos, H. Warren; Nikulla, Paul; Oliveira, Cristina M.; Saha, Timo T.; Obenschain, Arthur (Technical Monitor)

    2000-01-01

    The Far Ultraviolet Spectroscopic Explorer is a NASA astrophysics satellite which produces high-resolution spectra in the far-ultraviolet (90.5-118.7 nm bandpass) using a high effective area and low background detectors. The observatory was launched on its three-year mission from Cape Canaveral Air Station on 24 June 1999. The instrument contains four coaligned, normal incidence, off-axis parabolic mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographically ruled diffraction gratings and delay line microchannel plate detectors. The telescope mirrors have a 352 x 387 mm aperture and 2245 mm focal length and are attached to actuator assemblies, which provide on-orbit, tip, tilt, and focus control. Two mirrors are coated with silicon carbide (SiC) and two are coated with lithium fluoride over aluminum (Al:LiF). We describe mirror assembly in-flight optical and mechanical performance. On-orbit measurements of the far-ultraviolet point spread function associated with each mirror are compared to expectations based on pre-flight laboratory measurements and modeling using the Optical Surface Analysis Code and surface metrology data. On-orbit imaging data indicate that the mirrors meet their instrument-level requirement of 50 percent and 95 percent slit transmission for the high- and mid-resolution spectrograph entrance slits, respectively. The degradation of mirror reflectivity during satellite integration and test is also discussed. The far-ultraviolet reflectivity of the SiC- and AlLiF-coated mirrors decreased about six percent and three percent, respectively, between coating and launch. Each mirror is equipped with three actuators, which consist of a stepper motor driving a ball screw via a two-stage planetary gear train. We also discuss the mechanical performance of the mirror assemblies, including actuator performance and thermal effects.

  3. Generation of Mid-Infrared Frequency Combs for Spectroscopic Applications

    Science.gov (United States)

    Maser, Daniel L.

    Mid-infrared laser sources prove to be a valuable tool in exploring a vast array of phenomena, finding their way into applications ranging from trace gas detection to X-ray generation and carbon dating. Mid-infrared frequency combs, in particular, are well-suited for many of these applications, owing to their inherent low-noise and broadband nature. Frequency comb technology is well-developed in the near-infrared as a result of immense technological development by the telecommunication industry in silica fiber and the existence of readily-available glass dopants such as ytterbium and erbium that enable oscillators at 1 and 1.5 ?m. However, options become substantially more limited at longer wavelengths, as silica is no longer transparent and the components required in a mid-infrared frequency comb system (oscillators, fibers, and both fiber and free-space components) are far less technologically mature. This thesis explores several different approaches to generating frequency comb sources in the mid-infrared region, and the development of sources used in the nonlinear processes implemented to reach these wavelengths. An optical parametric oscillator, two approaches to difference frequency generation, and nonlinear spectral broadening in chip-scale waveguides are developed, characterized, and spectroscopic potential for these techniques is demonstrated. The source used for these nonlinear processes, the erbium-doped fiber amplifier, is also studied and discussed throughout the design and optimization process. The nonlinear optical processes critical to this work are numerically modeled and used to confirm and predict experimental behavior.

  4. SOFG: Standards requirements

    International Nuclear Information System (INIS)

    Gerganov, T.; Grigorov, S.; Kozhukharov, V.; Brashkova, N.

    2005-01-01

    It is well-known that Solid Oxide Fuel Cells will have industrial application in the nearest future. In this context, the problem of SOFC materials and SOFC systems standardization is of high level of priority. In the present study the attention is focused on the methods for physical and chemical characterization of the materials for SOFC components fabrication and about requirements on single SOFC cells tests. The status of the CEN, ISO, ASTM (ANSI, ASSN) and JIS class of standards has been verified. Standards regarding the test methods for physical-chemical characterization of vitreous materials (as sealing SOFC component), ceramic materials (as electrodes and electrolyte components, including alternative materials used) and metallic materials (interconnect components) are subject of overview. It is established that electrical, mechanical, surface and interfacial phenomena, chemical durability and thermal corrosion behaviour are the key areas for standardization of the materials for SOFC components

  5. Scrutinising safety standards

    Energy Technology Data Exchange (ETDEWEB)

    Pietersen, C.M. [Safety Service Center BV (Netherlands)

    2001-01-01

    Until the introduction of the International Electrotechnical Commission's standard IEC 61508, there was no provision for relating risks to people and the environment, to the risks of financial loss. Although IEC 61508 fills most of the gaps in the process industry, there are still some loopholes. Four points covered by the standard are listed. It is expected that the standard will lead to an optimum cost-benefit situation with 'fit-for-purpose' safety and minimum nuisance shutdowns, or process plant disturbances. It should give clear guidance on 'how safe is safe enough.' IEC 61508 can be implemented through various routes. Insurance companies and regulators are starting to require implementation of the new standard. Five points which need to be ascertained for implementation are listed and diagrams illustrate the IEC 61508 safety lifecycle and the risk-reduction requirements.

  6. STELLA Standards Framework.

    Science.gov (United States)

    English in Australia, 2001

    2001-01-01

    Presents a provisional framework for the STELLA (Standards for Teachers of English Language and Literacy in Australia), which identifies broad dimensions of teaching together with groupings of related attributes derived from teachers' narratives. (RS)

  7. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  8. National Pesticide Standard Repository

    Science.gov (United States)

    EPA's National Pesticide Standards Repository collects and maintains an inventory of analytical “standards” of registered pesticides in the United States, as well as some that are not currently registered for food and product testing and monitoring.

  9. Beyond the standard model

    International Nuclear Information System (INIS)

    Gaillard, M.K.

    1990-04-01

    The unresolved issues of the standard model are reviewed, with emphasis on the gauge hierarchy problem. A possible mechanism for generating a hierarchy in the context of superstring theory is described. 24 refs

  10. Standardization in synthetic biology.

    Science.gov (United States)

    Müller, Kristian M; Arndt, Katja M

    2012-01-01

    Synthetic Biology is founded on the idea that complex biological systems are built most effectively when the task is divided in abstracted layers and all required components are readily available and well-described. This requires interdisciplinary collaboration at several levels and a common understanding of the functioning of each component. Standardization of the physical composition and the description of each part is required as well as a controlled vocabulary to aid design and ensure interoperability. Here, we describe standardization initiatives from several disciplines, which can contribute to Synthetic Biology. We provide examples of the concerted standardization efforts of the BioBricks Foundation comprising the request for comments (RFC) and the Registry of Standardized Biological parts as well as the international Genetically Engineered Machine (iGEM) competition.

  11. AKRO: Standard Prices

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Standard prices are generated for cost recovery programs in the Individual Fishing Quota (IFQ) halibut and sablefish, BSAI Rationalized crab, and Central Gulf of...

  12. Fiber optics standard dictionary

    CERN Document Server

    Weik, Martin H

    1997-01-01

    Fiber Optics Vocabulary Development In 1979, the National Communications System published Technical InfonnationBulle­ tin TB 79-1, Vocabulary for Fiber Optics and Lightwave Communications, written by this author. Based on a draft prepared by this author, the National Communications System published Federal Standard FED-STD-1037, Glossary of Telecommunications Terms, in 1980 with no fiber optics tenns. In 1981, the first edition of this dictionary was published under the title Fiber Optics and Lightwave Communications Standard Dictionary. In 1982, the then National Bureau of Standards, now the National Institute of Standards and Technology, published NBS Handbook 140, Optical Waveguide Communications Glossary, which was also published by the General Services Admin­ istration as PB82-166257 under the same title. Also in 1982, Dynamic Systems, Inc. , Fiberoptic Sensor Technology Handbook, co-authored and edited by published the this author, with an extensive Fiberoptic Sensors Glossary. In 1989, the handbook w...

  13. FDA Recognized Consensus Standards

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database consists of those national and international standards recognized by FDA which manufacturers can declare conformity to and is part of the information...

  14. Spectroscopic noninvasive measurement of hemoglobin compared with capillary and venous values in neonates.

    Science.gov (United States)

    Rabe, H; Alvarez, R Fernandez; Whitfield, T; Lawson, F; Jungmann, H

    2010-06-01

    Venepuncture-related blood loss is a common cause of neonatal anemia. Currently, this is the only way to obtain hemoglobin levels. This causes distress for the infant but can also lead to the need for blood transfusions. Recently, a new technique for measuring hemoglobin levels non-invasively has been developed to reduce iatrogenic blood loss and pain. To compare hemoglobin levels obtained using a transcutaneous spectroscopic device (Mediscan 2000, MBR Optical Systems, Wuppertal, Germany) with venous or capillary blood samples in neonates. Single-center prospective cohort study of term and preterm infants. The white light spectroscopic device was placed on the forearm for 60 s to measure hemoglobin content within 4 h of venous or capillary blood sampling. Pain reactions of the infants were assessed by using a neonatal pain assessment tool. Results were analyzed by Bland-Altman comparison and Wilcoxon signed-rank test. 80 infants (mean gestational age 29.8 +/- 3.8 weeks, mean birth weight 1,300 +/- 690 g) were enrolled into the study. A total of 313 spectroscopic recordings within 2 h of a clinically indicated blood sample (181 capillary, 142 venous) were taken. The correlation coefficient R(2) was 0.96 for capillary/spectroscopic and 0.99 for venous/spectroscopic pairs. Pain scores were significantly less for the spectroscopic measurements (p < 0.01). The results show good correlation between the hemoglobin blood levels and spectroscopic measurements. The slightly lower correlation coefficient for the capillary samples demonstrates a naturally higher variance in these values due to the laboratory method.

  15. [Standardization of hospital feeding].

    Science.gov (United States)

    Caracuel García, Ángel Manuel

    2015-05-07

    Normalization can be understood as the establishing measures against repetitive situations through the development, dissemination, and application of technical design documents called standards. In Andalusia there are 45 public hospitals with 14,606 beds, and in which 11,700 full pensions / day are served. The Working Group on Hospital Food Standardization of the Andalusian Society for Clinical Nutrition and Dietetics, started in 2010, working on the certification of suppliers, product specifications, and meals technical card. - Develop a specific tool to help improving food safety through the certification of their suppliers. - Develop a standardized technical specifications of foodstuffs necessary for the development of menus established codes diets Andalusian hospitals document. - Develop a catalog of data sheets plates of hospital meals, to homogenize menus, respecting local and unifying criteria for qualitative and quantitative ingredients. - Providing documentation and studying of several public hospitals in Andalusia: • Product specifications and certification of suppliers. • International standards certification and distribution companies. • Legislation. • Data sheets for the menu items. • Specifications of different product procurement procedures. - Development of the draft standard HOSPIFOOD®, and approval of the version “0.0”. - Training course for auditors to this standard. - Development of a raw materials catalog as technical cards. - Meals Technical cards review and election of the ones which will be part of the document. After nearly three years of work, we have achieved the following products: - Standardized database of technical specifications for the production of food dietary codes for: fish, seafood, meat and meat products, meats and pates, ready meals, bread and pastries, preserves, milk and dairy products, oils, cereals, legumes , vegetables, fruits, fresh and frozen vegetables, condiments and spices. - Standardized database of

  16. The Gold Standard Programme

    DEFF Research Database (Denmark)

    Neumann, Tim; Rasmussen, Mette; Ghith, Nermin

    2013-01-01

    To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates.......To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates....

  17. Standard software for CAMAC

    International Nuclear Information System (INIS)

    Lenkszus, F.R.

    1978-01-01

    The NIM Committee (National Instrumentation Methods Committee) of the U.S. Department of Energy and the ESONE Committee of European Laboratories have jointly specified standard software for use with CAMAC. Three general approaches were followed: the definition of a language called IML for use in CAMAC systems, the definition of a standard set of subroutine calls, and real-time extensions to the BASIC language. This paper summarizes the results of these efforts. 1 table

  18. Beyond the standard model

    International Nuclear Information System (INIS)

    Pleitez, V.

    1994-01-01

    The search for physics laws beyond the standard model is discussed in a general way, and also some topics on supersymmetry theories. An approach is made on recent possibilities rise in the leptonic sector. Finally, models with SU(3) c X SU(2) L X U(1) Y symmetry are considered as alternatives for the extensions of the elementary particles standard model. 36 refs., 1 fig., 4 tabs

  19. Technical standards in nuclear area

    International Nuclear Information System (INIS)

    Grimberg, M.

    1978-01-01

    The technical standardization in nuclear area is discussed. Also, the competence of CNEN in standardization pursuit is analysed. Moreover, the process of working up of technical standards is explained; in addition, some kinds of technical standards are discussed. (author) [pt

  20. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  1. Interaction of an antiepileptic drug, lamotrigine with human serum albumin (HSA): Application of spectroscopic techniques and molecular modeling methods.

    Science.gov (United States)

    Poureshghi, Fatemeh; Ghandforoushan, Parisa; Safarnejad, Azam; Soltani, Somaieh

    2017-01-01

    Lamotrigine (an epileptic drug) interaction with human serum albumin (HSA) was investigated by fluorescence, UV-Vis, FTIR, CD spectroscopic techniques, and molecular modeling methods. Binding constant (K b ) of 5.74×10 3 and number of binding site of 0.97 showed that there is a slight interaction between lamotrigine and HSA. Thermodynamic studies was constructed using the flourimetric titrations in three different temperatures and the resulted data used to calculate the parameters using Vant Hoff equation. Decreased Stern Volmer quenching constant by enhanced temperature revealed the static quenching mechanism. Negative standard enthalpy (ΔH) and standard entropy (ΔS) changes indicated that van der Waals interactions and hydrogen bonds were dominant forces which facilitate the binding of Lamotrigine to HSA, the results were confirmed by molecular docking studies which showed no hydrogen binding. The FRET studies showed that there is a possibility of energy transfer between Trp214 and lamotrigine. Also the binding of lamotrigine to HSA in the studied concentrations was not as much as many other drugs, but the secondary structure of the HSA was significantly changed following the interaction in a way that α-helix percentage was reduced from 67% to 57% after the addition of lamotrigine in the molar ratio of 4:1 to HSA. According to the docking studies, lamotrigine binds to IB site preferably. Copyright © 2016. Published by Elsevier B.V.

  2. DOE technical standards list. Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  3. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  4. HITRAN Application Programming Interface (HAPI): A comprehensive approach to working with spectroscopic data

    International Nuclear Information System (INIS)

    Kochanov, R.V.; Gordon, I.E.; Rothman, L.S.; Wcisło, P.; Hill, C.; Wilzewski, J.S.

    2016-01-01

    The HITRAN Application Programming Interface (HAPI) is presented. HAPI is a free Python library, which extends the capabilities of the HITRANonline interface ( (www.hitran.org)) and can be used to filter and process the structured spectroscopic data. HAPI incorporates a set of tools for spectra simulation accounting for the temperature, pressure, optical path length, and instrument properties. HAPI is aimed to facilitate the spectroscopic data analysis and the spectra simulation based on the line-by-line data, such as from the HITRAN database [JQSRT (2013) 130, 4–50], allowing the usage of the non-Voigt line profile parameters, custom temperature and pressure dependences, and partition sums. The HAPI functions allow the user to control the spectra simulation and data filtering process via a set of the function parameters. HAPI can be obtained at its homepage (www.hitran.org/hapi). - Highlights: • HAPI extends the HITRANonline portal and provides an access to the HITRAN data. • Free, flexible, and portable Python library for working with the spectroscopic data. • Incorporates functions for querying, filtering and processing the spectroscopic data. • Provides functionality for single-layer spectra simulation. • Can be used in the radiative transfer codes, spectroscopic data validation, etc.

  5. Spectroscopic properties for identifying sapphire samples from Ban Bo Kaew, Phrae Province, Thailand

    Science.gov (United States)

    Mogmued, J.; Monarumit, N.; Won-in, K.; Satitkune, S.

    2017-09-01

    Gemstone commercial is a high revenue for Thailand especially ruby and sapphire. Moreover, Phrae is a potential gem field located in the northern part of Thailand. The studies of spectroscopic properties are mainly to identify gemstone using advanced techniques (e.g. UV-Vis-NIR spectrophotometry, FTIR spectrometry and Raman spectroscopy). Typically, UV-Vis-NIR spectrophotometry is a technique to study the cause of color in gemstones. FTIR spectrometry is a technique to study the functional groups in gem-materials. Raman pattern can be applied to identify the mineral inclusions in gemstones. In this study, the natural sapphires from Ban Bo Kaew were divided into two groups based on colors including blue and green. The samples were analyzed by UV-Vis-NIR spectrophotometer, FTIR spectrometer and Raman spectroscope for studying spectroscopic properties. According to UV-Vis-NIR spectra, the blue sapphires show higher Fe3+/Ti4+ and Fe2+/Fe3+ absorption peaks than those of green sapphires. Otherwise, green sapphires display higher Fe3+/Fe3+ absorption peaks than blue sapphires. The FTIR spectra of both blue and green sapphire samples show the absorption peaks of -OH,-CH and CO2. The mineral inclusions such as ferrocolumbite and rutile in sapphires from this area were observed by Raman spectroscope. The spectroscopic properties of sapphire samples from Ban Bo Kaew, Phrae Province, Thailand are applied to be the specific evidence for gemstone identification.

  6. IAEA Safety Standards

    International Nuclear Information System (INIS)

    2016-09-01

    The IAEA Safety Standards Series comprises publications of a regulatory nature covering nuclear safety, radiation protection, radioactive waste management, the transport of radioactive material, the safety of nuclear fuel cycle facilities and management systems. These publications are issued under the terms of Article III of the IAEA’s Statute, which authorizes the IAEA to establish “standards of safety for protection of health and minimization of danger to life and property”. Safety standards are categorized into: • Safety Fundamentals, stating the basic objective, concepts and principles of safety; • Safety Requirements, establishing the requirements that must be fulfilled to ensure safety; and • Safety Guides, recommending measures for complying with these requirements for safety. For numbering purposes, the IAEA Safety Standards Series is subdivided into General Safety Requirements and General Safety Guides (GSR and GSG), which are applicable to all types of facilities and activities, and Specific Safety Requirements and Specific Safety Guides (SSR and SSG), which are for application in particular thematic areas. This booklet lists all current IAEA Safety Standards, including those forthcoming

  7. GISB: Efficiency through standardization

    International Nuclear Information System (INIS)

    White, B.

    1995-01-01

    For those who participated in the numerous day-long development sessions held in the dim, stale basement auditorium of the Department of Energy, the ida that the Gas Industry standards Board (GISB) would be producing standards anytime soon seemed a distant dream. However, the hazy vision of just over a year ago has now become a reality. As summer turns to fall and young gas schedulers throughout this country dream of the gridiron, GISB will have already issued a model electronic-trading partner agreement and 12 standards for capacity-release transactions, as well as three standards for nomination-related transactions. Under the steady hand of Executive directors Rae McQuade and a board of director that looks like a Who's Who of the gas industry, GISB has developed into a organization that will directly influence how gas is purchased, transported, and accounted and paid for in the 21st century. The paper describes the background of the organization, standards that have been released, and issues still to be addressed

  8. Sports eyewear protective standards.

    Science.gov (United States)

    Dain, Stephen J

    2016-01-01

    Eye injuries sustained during sport comprise up to 20 per cent of all injuries to the eye serious enough for medical attention to be sought. The prevalence of eye injuries in sport is not easily assessed due to lack of authoritative participation rates, so most studies report total numbers in a time period. The evidence on the proportion of all ocular injuries that are from sport is reviewed. The relative frequencies in different sports are compared in a qualitative manner and the sports with greater numbers of ocular injuries are detailed. In common with occupational injuries to the eye, most sports eye injuries are considered preventable. The hierarchy of action for occupational risk is detailed and adapted to use in a sports scenario. All the available international, regional and national standards on sports eye protection are detailed and their provisions compared. The major function of the standards is to provide adequate protection against the hazard of the sport concerned. These are detailed and compared as a function of energy transfer. Eye protection must not introduce additional or secondary hazards (for instance, fracturing into sharp fragments on impact) and not introduce features that would deter the wearing of eye protection (for instance, restricting field of view to impede playing the sport). The provisions of the standards intended to limit secondary hazards are detailed and compared. The need for future work in standards writing and the activities of the International Standardization Organization in sports eye protection are detailed. © 2016 Optometry Australia.

  9. Nuclear Magnetic Resonance (NMR) Spectroscopic Characterization of Nanomaterials and Biopolymers

    Science.gov (United States)

    Guo, Chengchen

    Nanomaterials have attracted considerable attention in recent research due to their wide applications in various fields such as material science, physical science, electrical engineering, and biomedical engineering. Researchers have developed many methods for synthesizing different types of nanostructures and have further applied them in various applications. However, in many cases, a molecular level understanding of nanoparticles and their associated surface chemistry is lacking investigation. Understanding the surface chemistry of nanomaterials is of great significance for obtaining a better understanding of the properties and functions of the nanomaterials. Nuclear magnetic resonance (NMR) spectroscopy can provide a familiar means of looking at the molecular structure of molecules bound to surfaces of nanomaterials as well as a method to determine the size of nanoparticles in solution. Here, a combination of NMR spectroscopic techniques including one- and two-dimensional NMR spectroscopies was used to investigate the surface chemistry and physical properties of some common nanomaterials, including for example, thiol-protected gold nanostructures and biomolecule-capped silica nanoparticles. Silk is a natural protein fiber that features unique properties such as excellent mechanical properties, biocompatibility, and non-linear optical properties. These appealing physical properties originate from the silk structure, and therefore, the structural analysis of silk is of great importance for revealing the mystery of these impressive properties and developing novel silk-based biomaterials as well. Here, solid-state NMR spectroscopy was used to elucidate the secondary structure of silk proteins in N. clavipes spider dragline silk and B. mori silkworm silk. It is found that the Gly-Gly-X (X=Leu, Tyr, Gln) motif in spider dragline silk is not in a beta-sheet or alpha-helix structure and is very likely to be present in a disordered structure with evidence for 31-helix

  10. Spectroscopic evolution of massive stars on the main sequence

    Science.gov (United States)

    Martins, F.; Palacios, A.

    2017-02-01

    Context. The evolution of massive stars depends on several parameters, and the relation between different morphological types is not fully constrained. Aims: We aim to provide an observational view of evolutionary models in the Hertzsprung-Russell diagram, on the main sequence. This view should help compare observations and model predictions. Methods: We first computed evolutionary models with the code STAREVOL for initial masses between 15 and 100 M⊙. We subsequently calculated atmosphere models at specific points along the evolutionary tracks, using the code CMFGEN. Synthetic spectra obtained in this way were classified as if they were observational data: we assigned them a spectral type and a luminosity class. We tested our spectral classification by comparison to observed spectra of various stars with different spectral types. We also compared our results with empirical data of a large number of OB stars. Results: We obtain spectroscopic sequences along evolutionary tracks. In our computations, the earliest O stars (O2-3.5) appear only above 50 M⊙. For later spectral types, a similar mass limit exists, but is lower. A luminosity class V does not correspond to the entire main sequence. This only holds for the 15 M⊙ track. As mass increases, a larger portion of the main sequence is spent in luminosity class III. Above 50 M⊙, supergiants appear before the end of core-hydrogen burning. Dwarf stars (luminosity class V) do not occur on the zero-age main sequence above 80 M⊙. Consequently, the distribution of luminosity class V in the HR diagram is not a diagnostic of the length of the main sequence (above 15 M⊙) and cannot be used to constrain the size of the convective core. The distribution of dwarfs and giants in the HR diagram that results from our calculations agrees well with the location of stars analyzed by means of quantitative spectroscopy. For supergiants, there is a slight discrepancy in the sense that luminosity class I is observed slightly

  11. Standards and quality

    CERN Document Server

    El-Tawil, Anwar

    2015-01-01

    The book brings together a number of subjects of prime importance for any practicing engineer and, students of engineering. The book explains the concepts and functions of voluntary standards, mandatory technical regulations, conformity assessment (testing and measurement of products), certification, quality and quality management systems as well as other management systems such as environmental, social responsibility and food safety management systems.The book also gives a comprehensive description of the role of metrology systems that underpin conformity assessment. A description is given of typical national systems of standards, quality and metrology and how they relate directly or through regional structures to international systems. The book also covers the relation between standards and trade and explains the context and stipulations of the Technical Barriers to Trade Agreement of the World Trade Organization (WTO).

  12. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1983-10-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience

  13. Standardization of depression measurement

    DEFF Research Database (Denmark)

    Wahl, Inka; Löwe, Bernd; Bjørner, Jakob

    2014-01-01

    OBJECTIVES: To provide a standardized metric for the assessment of depression severity to enable comparability among results of established depression measures. STUDY DESIGN AND SETTING: A common metric for 11 depression questionnaires was developed applying item response theory (IRT) methods. Data...... of 33,844 adults were used for secondary analysis including routine assessments of 23,817 in- and outpatients with mental and/or medical conditions (46% with depressive disorders) and a general population sample of 10,027 randomly selected participants from three representative German household surveys....... RESULTS: A standardized metric for depression severity was defined by 143 items, and scores were normed to a general population mean of 50 (standard deviation = 10) for easy interpretability. It covers the entire range of depression severity assessed by established instruments. The metric allows...

  14. SU-E-J-197: A Novel Optical Interstitial Fiber Spectroscopic System for Real-Time Tissue Micro-Vascular Hemodynamics Monitoring.

    Science.gov (United States)

    Zhao, D; Campos, D; Yan, Y; Kimple, R; Jacques, S; van der Kogel, A; Kissick, M

    2012-06-01

    To demonstrate a novel interstitial optical fiber spectroscopic system, based on diffuse optical spectroscopies with spectral fitting, for the simultaneous monitoring of tumor blood volume and oxygen tension. The technique provides real-time, minimally-invasive and quantification of tissue micro-vascular hemodynamics. An optical fiber prototype probe characterizesthe optical transport in tissue between two large Numerical Aperture (NA) fibers of 200μm core diameter (BFH37-200, ThorLabs) spaced 3-mm apart. Two 21-Ga medical needles are used to protect fiber ends and to facilitate tissue penetration with minimum local blunt trauma in nude mice with xenografts. A 20W white light source (HL-2000-HP, Ocean Optics) is coupled to one fiber with SMA adapter. The other fiber is used to collect light, which is coupled into the spectrometer (QE65000 with Spectrasuite Operating software and OmniDriver, Ocean Optics). The wavelength response of the probe depends on the wavelength dependence of the light source, and of the light signal collection that includes considerable scatter, modeled with Monte-Carlo techniques (S. Jacques 2010 J. of Innov. Opt. Health Sci. 2 123-9). Measured spectra of tissue are normalized by a measured spectrum of a white standard, yielding the transmission spectrum. A head-and-neck xenograft on the flank of a live mouse is used for development. The optical fiber probe delivers and collects light at an arbitrary depth in the tumor. By spectral fitting of the measured transmission spectrum, an analysis of blood volume and oxygen tension is obtained from the fitting parameters in real time. A newly developed optical fiber spectroscopic system with an optical fiber probe takes spectroscopic techniques to a much deeper level in a tumor, which has potential applications for real-time monitoring hypoxic cell population dynamics for an eventual adaptive therapy metric of particular use in hypofractionated radiotherapy. © 2012 American Association of

  15. High sensitivity CRDS of CO2 in the 1.74 μm transparency window. A validation test for the spectroscopic databases

    Science.gov (United States)

    Čermák, P.; Karlovets, E. V.; Mondelain, D.; Kassi, S.; Perevalov, V. I.; Campargue, A.

    2018-03-01

    The very weak absorption spectrum of natural CO2 near 1.74 μm (5702-5879 cm-1) is studied at high sensitivity. The investigated region corresponds to a transparency window of very weak opacity which is of particular interest for Venus. Very weak lines with intensity value as low as 10-30 cm/molecule at 296 K are detected by Cavity Ring Down Spectroscopy. On the basis of the predictions of effective Hamiltonian models, 1135 lines of six carbon dioxide isotopologues - 12C16O2, 13C16O2, 16O12C18O, 16O12C17O, 16O13C18O and 16O13C17O - were rovibrationnally assigned to 26 bands. The accurate spectroscopic parameters of 16 bands are determined from standard band-by-band analysis (typical rms deviations of the line positions are 8 × 10-4 cm-1). These newly observed bands include perturbed bands, weak hot bands and bands of minor isotopologues (in particular 16O12C18O in natural abundance) and provide critical validation tests for the most recent spectroscopic databases. The comparison to the Carbon Dioxide Spectroscopic Databank (CDSD), HITRAN2016 database and recent ab initio line lists is presented. Deficiencies are evidenced for some weak perpendicular bands of the HITRAN2016 list and identified as due to inaccurate CDSD intensities which were preferred to ab initio intensities. While Ames and UCL ab initio intensities are believed to be accurate within a few % for the strong unperturbed bands, the reported measurements allow testing important (>50%) differences between ab initio values of some weak perturbed bands.

  16. nmr spectroscopic study and dft calculations of giao nmr shieldings

    African Journals Online (AJOL)

    Preferred Customer

    NMR is a sensitive and versatile probe of molecular-scale structure and dynamics in solids and liquids. It has been widely used in chemistry, materials and geochemistry [21-23] and it enables one to get faster and easier structural information. The standard 1D and 2D hetero and homonuclear NMR experiments are enough ...

  17. Fundamental spectroscopic studies of carbenes and hydrocarbon radicals

    Energy Technology Data Exchange (ETDEWEB)

    None

    1999-03-12

    Determination of bond dissociation energies and heats of formation of hydrocarbon radicals and carbenes requires knowledge of their structures, but this is not provided by standard mass spectrometric studies; what is needed is high-resolution spectroscopy, often best achieved at centimeter and millimeter wavelengths. Nearly 60 reactive organic molecules were investigated in the period from 1988--1998.

  18. Synthesis, Spectroscopic Properties and DFT Calculation of Novel ...

    Indian Academy of Sciences (India)

    excited states were calculated by using the TD-DFT method. In all calculations, squeezed self-consistent field. (SCF) convergence standards, the self-consistent reac- tion field (SCRF) method and polarized continuum model (PCM)33,34 were adopted. The UV-Vis spectra were computed from TD-DFT calculations in differ-.

  19. Conference: STANDARD MODEL @ LHC

    CERN Multimedia

    2012-01-01

    HCØ institute Universitetsparken 5 DK-2100 Copenhagen Ø Denmark Room: Auditorium 2 STANDARD MODEL @ LHC Niels Bohr International Academy and Discovery Center 10-13 April 2012 This four day meeting will bring together both experimental and theoretical aspects of Standard Model phenomenology at the LHC. The very latest results from the LHC experiments will be under discussion. Topics covered will be split into the following categories:     * QCD (Hard,Soft & PDFs)     * Vector Boson production     * Higgs searches     * Top Quark Physics     * Flavour physics

  20. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1987-05-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes