WorldWideScience

Sample records for stand-alone system independent

  1. Stand alone photovoltaic systems: guarantee of results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This study aims to provide a guarantee of results for system performance for users of stand-alone photovoltaic (PV) systems, which have no back-up generator. The appropriate main performance criterion for PV systems is that a specified load is supplied with power either continuously or intermittently whenever the load requires power. A methodology to evaluate the power availability of stand-alone PV systems has been developed as part of the project, which encompasses power losses due to weather variations. The guarantee of results produced allows users to compare system designs from different manufacturers. (UK)

  2. Stand Alone Battery Thermal Management System

    Energy Technology Data Exchange (ETDEWEB)

    Brodie, Brad [Denso International America, Incorporated, Southfield, MI (United States)

    2015-09-30

    The objective of this project is research, development and demonstration of innovative thermal management concepts that reduce the cell or battery weight, complexity (component count) and/or cost by at least 20%. The project addresses two issues that are common problems with current state of the art lithium ion battery packs used in vehicles; low power at cold temperatures and reduced battery life when exposed to high temperatures. Typically, battery packs are “oversized” to satisfy the two issues mentioned above. The first phase of the project was spent making a battery pack simulation model using AMEsim software. The battery pack used as a benchmark was from the Fiat 500EV. FCA and NREL provided vehicle data and cell data that allowed an accurate model to be created that matched the electrical and thermal characteristics of the actual battery pack. The second phase involved using the battery model from the first phase and evaluate different thermal management concepts. In the end, a gas injection heat pump system was chosen as the dedicated thermal system to both heat and cool the battery pack. Based on the simulation model. The heat pump system could use 50% less energy to heat the battery pack in -20°C ambient conditions, and by keeping the battery cooler at hot climates, the battery pack size could be reduced by 5% and still meet the warranty requirements. During the final phase, the actual battery pack and heat pump system were installed in a test bench at DENSO to validate the simulation results. Also during this phase, the system was moved to NREL where testing was also done to validate the results. In conclusion, the heat pump system can improve “fuel economy” (for electric vehicle) by 12% average in cold climates. Also, the battery pack size, or capacity, could be reduced 5%, or if pack size is kept constant, the pack life could be increased by two years. Finally, the total battery pack and thermal system cost could be reduced 5% only if the

  3. Ampere hour method of sizing a stand alone photovoltaic system ...

    African Journals Online (AJOL)

    Stand-alone photovoltaic power systems are natural options for application in electrification of remote areas which are not served by the grid electricity supply system. An ampere-hour ... Sizing of the balance-of-system were carefully handled to avoid undersizing or oversizing and subsequent variation in supply reliability.

  4. Optimal sizing method for stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Groumpos, P P; Papageorgiou, G

    1987-01-01

    The total life-cycle cost of stand-alone photovoltaic (SAPV) power systems is mathematically formulated. A new optimal sizing algorithm for the solar array and battery capacity is developed. The optimum value of a balancing parameter, M, for the optimal sizing of SAPV system components is derived. The proposed optimal sizing algorithm is used in an illustrative example, where a more economical life-cycle cost has bene obtained. The question of cost versus reliability is briefly discussed.

  5. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.

    2001-01-01

    are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model(KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program......This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risø National Laboratory. The work has been supported by the Danish Ministry ofEnergy, as a part of the activities in the Solar...... Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery...

  6. Future UK markets for stand-alone renewable energy systems

    International Nuclear Information System (INIS)

    Paish, O.

    1999-01-01

    A study to identify and quantify the market for stand-alone renewable energy supplies of power (photovoltaics, wind and micro-hydro electricity systems) was described. The study focused on small systems, generally less than a few kW installed capacity. It was suggested that in the UK, the emphasis on grid-connected renewable energy technologies (RETs) has blurred the fact that it is 'off-grid' renewable systems that can offer more immediate real commercial markets for the renewables business. With the likelihood of a significant increase in demand for renewables world wide over the next ten years, the UK needs to make a special effort to become involved

  7. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  8. Size-Prediction Analysis for Stand-Alone Photovoltaic System

    International Nuclear Information System (INIS)

    Erusiafe, N. E.; Chendo, M. A. C.

    2002-01-01

    The cost - effectiveness of photovoltaic (PV) generator depends, among others, on its ability to satisfy energy demand and the cost of achieving this. In this work a step - by - step procedure for predicting the size of the main components of a stand - alone PV system (array and storage) is presented. The results yield an expression which can he used lo determine the size of both components at optimum cost and desired reliability. The result from this work compare favourably with some earlier works in that, the system sizes shows some degree of agreement

  9. Availability model of stand-alone photovoltaic system

    Science.gov (United States)

    Mazurek, G.

    2017-08-01

    In this paper we present a simple, empirical model of stand-alone photovoltaic power system availability. The model is a final result of five-year long studies and ground measurements of solar irradiation carried out in Central Europe. The obtained results facilitate sizing of PV modules that have to be installed with taking into account system's availability level in each month of a year. The model can be extended to different geographical locations, with help of local meteorological data or solar irradiation datasets derived from satellite measurements.

  10. R and D into stand-alone PV systems for export

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The current status of photovoltaic (PV) technology is reviewed for systems to provide electricity where mains supplies are unavailable, known as stand-alone PV systems. Typical applications and experiences with installed stand-alone systems are described. Economic issues and barriers to the wide use of PV systems are also examined. (UK)

  11. Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems; TOPICAL

    International Nuclear Information System (INIS)

    DeBlasio, R.; Durand, S.; Hansen, R.; Hutchinson, P.; Kroposki, B.; McNutt, P.; Rosenthal, A.; Thomas, M.

    1999-01-01

    This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested

  12. System Simulation by Recursive Feedback: Coupling a Set of Stand-Alone Subsystem Simulations

    Science.gov (United States)

    Nixon, D. D.

    2001-01-01

    Conventional construction of digital dynamic system simulations often involves collecting differential equations that model each subsystem, arran g them to a standard form, and obtaining their numerical gin solution as a single coupled, total-system simultaneous set. Simulation by numerical coupling of independent stand-alone subsimulations is a fundamentally different approach that is attractive because, among other things, the architecture naturally facilitates high fidelity, broad scope, and discipline independence. Recursive feedback is defined and discussed as a candidate approach to multidiscipline dynamic system simulation by numerical coupling of self-contained, single-discipline subsystem simulations. A satellite motion example containing three subsystems (orbit dynamics, attitude dynamics, and aerodynamics) has been defined and constructed using this approach. Conventional solution methods are used in the subsystem simulations. Distributed and centralized implementations of coupling have been considered. Numerical results are evaluated by direct comparison with a standard total-system, simultaneous-solution approach.

  13. Design of Stand-Alone Hybrid Power Generation System at Brumbun Beach Tulungagung East Java

    Science.gov (United States)

    Rahmat, A. N.; Hidayat, M. N.; Ronilaya, F.; Setiawan, A.

    2018-04-01

    Indonesian government insists to optimize the use of renewable energy resources in electricity generation. One of the efforts is launching Independent Energy Village plan. This program aims to fulfill the need of electricity for isolated or remote villages in Indonesia. In order to support the penetration of renewable energy resources in electricity generation, a hybrid power generation system is developed. The simulation in this research is based on the availability of renewable energy resources in Brumbun beach, Tulungagung, East Java. Initially, the electricity was supplied through stand-alone electricity generations which are installed at each house. Hence, the use of electricity between 5 p.m. – 9 p.m. requires high operational costs. Based on the problem above, this research is conducted to design a stand-alone hybrid electricity generation system, which may consist of diesel, wind, and photovoltaic. The design is done by using HOMER software to optimize the use of electricity from renewable resources and to reduce the operation of diesel generation. The combination of renewable energy resources in electricity generation resulted in NPC of 44.680, COE of 0,268, and CO2 emissions of 0,038 % much lower than the use of diesel generator only.

  14. Algal Hydrogen Production -- Stand Alone or Integrated System?

    Energy Technology Data Exchange (ETDEWEB)

    Ghirardi, Maria L.; Maness, Pin Ching; Kosourovo, Sergey

    2016-01-01

    Photosynthetic bacteria and green algae photoproduce H2. but do so utilizing different catalysts and substrates. Green algae use reductant generate mostly by water oxidation to catalyze the reduction of protons to H2 gas, while photosynthetic bacteria catalyze H2 production from organic acids using the nitrogenase enzyme. Moreover, these two organisms utilize different regions of the solar spectrum to perform photosynthesis: green algae's light harvesting antenna is comprised of chlorophyll molecules that absorb mostly blue and red light; photosynthetic bacteria harvest blue and far-red light through their light-harvesting pigments to run its non-oxygenic photosynthetic reactions. There is thus an opportunity to increase the range of solar spectrum used to photoproduce H2 by combining the light-harvesting and catalytic properties of these two organisms in a single process. In the current manuscript, we describe an experimental system that validates this hypothesis and demonstrates quantitatively the advantages of a two organism process for production of higher amounts of H2 and thus achieving solar light conversion efficiencies.

  15. Stand-alone wind system with Vanadium Redox Battery energy storage

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Barote, L.; Weissbach, R.

    2008-01-01

    Energy storage devices are required for power balance and power quality in stand alone wind energy systems. A Vanadium Redox Flow Battery (VRB) system has many features which make its integration with a stand-alone wind energy system attractive. This paper proposes the integration of a VRB system...... with a typical stand-alone wind energy system during wind speed variation as well as transient performance under variable load. The investigated system consists of a variable speed wind turbine with permanent magnet synchronous generator (PMSG), diode rectifier bridge, buck-boost converter, bidirectional charge...... controller, transformer, inverter, ac loads and VRB (to store a surplus of wind energy and to supply power during a wind power shortage). The main purpose is to supply domestic appliances through a single phase 230V, 50Hz inverter. Simulations are accomplished in order to validate the stability of the supply....

  16. Stand-alone photovoltaic systems in the Netherlands. Evaluation of the market introduction

    International Nuclear Information System (INIS)

    Cloin, J.; Van Dijk, A.L.; Westra, C.A.

    1999-08-01

    The policy followed for stand-alone PV systems in the Netherlands is evaluated for the period 1997-1998. The world-wide powerful growth of the PV industry is not being followed by the increase in volume of implemented stand-alone PV systems in the Netherlands. This leads to the question whether the Dutch policy to stimulate stand-alone PV systems is effective. Recommendations on the use of communication as a strategic instrument are given, including the drawing up of a marketing plan. Other recommendations include increased transparency in the application for subsidies and a pro-active role of the Netherlands Agency for Energy and the Environment (Novem) in the contact with relevant market parties. The increased focus on product development aimed at the environmental benefits and general reliability of PV systems is recommended. 38 refs

  17. Use of Super-Capacitor to Enhance Charging Performance of Stand-Alone Solar PV System

    KAUST Repository

    Huang, B. J.; Hsu, P. C.; Ho, P. Y

    2011-01-01

    Introduction: The battery charging performance in a stand-alone solar PV system affects the PV system efficiency and the load operating time. The New Energy Center of National Taiwan University has been devoted to the development of a PWM charging

  18. Use of appliances in stand-alone PV power supply systems: problems and solutions. Task 3 use of photovoltaic power systems in stand-alone and island applications

    Energy Technology Data Exchange (ETDEWEB)

    Vallve, X.; Gafas, G. [IEA PVPS, Task 3 (Spain); Villoz, M. [IEA PVPS, Task 3 (Switzerland); Wilshaw, A. [IEA PVPS, Task 3 (United Kingdom); Jacquin, P. [IEA PVPS, Task 3 (France)

    2002-09-15

    In Stand-Alone Photovoltaic Systems (SAPV systems), special attention must be paid to the used appliances and loads. Inappropriate loads are very often the origin of PV system malfunction or failure. Start-up power peaks, or reactive power and harmonic distortion can cause system signal instability and protective devices will close the system down. A well-matched load together with a carefully selected choice of appliances can lead to significant savings in terms of reduced need for PV and electricity storage capacity. Conversely, inefficient appliances and processes, standby loads and inappropriate loads will increase the requirement for expensive PV and storage capacity. This paper presents a survey of real cases with load related problems in worldwide applications, their effect on quality and cost of the service and the solutions that were adopted and suggested alternative solutions. One of the main conclusions of the work is the importance to integrate the choice of the appliance while designing the SAPV system. (author)

  19. Information systems for the materials management department: stand-alone and enterprise resource planning systems.

    Science.gov (United States)

    2005-03-01

    Materials management information systems (MMISs) incorporate information tools that hospitals can use to automate certain business processes, increase staff compliance with these processes, and identify opportunities for cost savings. Recently, there has been a push by hospital administration to purchase enterprise resource planning (ERP) systems, information systems that promise to integrate many more facets of healthcare business. We offer this article to help materials managers, administrators, and others involved with information system selection understand the changes that have taken place in materials management information systems, decide whether they need a new system and, if so, whether a stand-alone MMIS or an ERP system will be the best choice.

  20. Secure stand alone positive personnel identity verification system (SSA-PPIV)

    International Nuclear Information System (INIS)

    Merillat, P.D.

    1979-03-01

    The properties of a secure stand-alone positive personnel identity verification system are detailed. The system is designed to operate without the aid of a central computing facility and the verification function is performed in the absence of security personnel. Security is primarily achieved by means of data encryption on a magnetic stripe badge. Several operational configurations are discussed. Advantages and disadvantages of this system compared to a central computer driven system are detailed

  1. A new approach for sizing stand alone photovoltaic systems based in neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Hontoria, L.; Aguilera, J. [Universidad de Jaen, Dept. de Electronica, Jaen (Spain); Zufiria, P. [UPM Ciudad Universitaria, Dept. de Matematica Aplicada a las Tecnologias de la Informacion, Madrid (Spain)

    2005-02-01

    Several methods for sizing stand alone photovoltaic (pv) systems has been developed. The more simplistic are called intuitive methods. They are a useful tool for a first approach in sizing stand alone photovoltaic systems. Nevertheless they are very inaccurate. Analytical methods use equations to describe the pv system size as a function of reliability. These ones are more accurate than the previous ones but they are also not accurate enough for sizing of high reliability. In a third group there are methods which use system simulations. These ones are called numerical methods. Many of the analytical methods employ the concept of reliability of the system or the complementary term: loss of load probability (LOLP). In this paper an improvement for obtaining LOLP curves based on the neural network called Multilayer Perceptron (MLP) is presented. A unique MLP for many locations of Spain has been trained and after the training, the MLP is able to generate LOLP curves for any value and location. (Author)

  2. Stand-Alone Solar Organic Rankine Cycle Water Pumping System and Its Economic Viability in Nepal

    OpenAIRE

    Suresh Baral; Kyung Chun Kim

    2015-01-01

    The current study presents the concept of a stand-alone solar organic Rankine cycle (ORC) water pumping system for rural Nepalese areas. Experimental results for this technology are presented based on a prototype. The economic viability of the system was assessed based on solar radiation data of different Nepalese geographic locations. The mechanical power produced by the solar ORC is coupled with a water pumping system for various applications, such as drinking and irrigation. The thermal ef...

  3. Modeling, Design and Simulation of Stand-Alone Photovoltaic Power Systems with Battery Storage

    Directory of Open Access Journals (Sweden)

    Abd Essalam BADOUD

    2013-06-01

    Full Text Available Stand alone renewable energy based on photovoltaic systems accompanied with battery storage system are beginning to play an important role over the world to supply power to remote areas. The objective of the study reported in this paper is to elaborate and design a bond graphs model for sizing stand-alone domestic solar photovoltaic electricity systems and simulating the performance of the systems in a tropical climate. The systems modelled consist of an array of PV modules, a lead-acid battery, and a number of direct current appliances. This paper proposes the combination of lead acid battery system with a typical stand alone photovoltaic energy system under variable loads. The main activities of this work purpose to establish library graphical models for each individual component of standalone photovoltaic system. Control strategy has been considered to achieve permanent power supply to the load via photovoltaic/battery based on the power available from the sun. The complete model was simulated under two testing including sunny and cloudy conditions. Simulation of the system using Symbols software was performed and the results of simulation show the superior stable control system and high efficiency. These results have been contrasted with real measured data from a measurement campaign plant carried on electrical engineering laboratory of Grenoble using various interconnection schemes are presented.

  4. System design optimization for stand-alone photovoltaic systems sizing by using superstructure model

    International Nuclear Information System (INIS)

    Azau, M A M; Jaafar, S; Samsudin, K

    2013-01-01

    Although the photovoltaic (PV) systems have been increasingly installed as an alternative and renewable green power generation, the initial set up cost, maintenance cost and equipment mismatch are some of the key issues that slows down the installation in small household. This paper presents the design optimization of stand-alone photovoltaic systems using superstructure model where all possible types of technology of the equipment are captured and life cycle cost analysis is formulated as a mixed integer programming (MIP). A model for investment planning of power generation and long-term decision model are developed in order to help the system engineer to build a cost effective system.

  5. A Three-Port Topology Comparison for a Low Power Stand-Alone Photovoltaic System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using c...... component stress factor (CSF) is performed, which gives a quantitative measure of the performance of the converter. The candidate topologies are compared to each other according to a defined LED lighting strategy and a solar irradiation profile.......Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using...

  6. MOSFET Loss Evaluation for a Low-Power Stand-Alone Photovoltaic-LED System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2015-01-01

    This paper presents a performance evaluation and comparison of state-of-the-art low voltage Si MOSFETs for a stand-alone photovoltaic-LED Light to Light (LtL) system. The complete system is formed by two cascaded converters that will be optimized for a determined solar irradiation and LED...... illumination profiles. The comparison is performed based on dynamic characterization and evaluation of the devices energy loss at different current levels....

  7. Hybrid Configuration of Darrieus and Savonius Rotors for Stand-alone Power Systems

    Science.gov (United States)

    Wakui, Tetsuya; Tanzawa, Yoshiaki; Hashizume, Takumi; Nagao, Toshio

    The suitable hybrid configuration of Darrieus lift-type and Savonius drag-type rotors for stand-alone wind turbine-generator systems is discussed using our dynamic simulation model. Two types of hybrid configurations are taken up: Type-A installs the Savonius rotor inside the Darrieus rotor and Type-B installs the Savonius rotor outside the Darrieus rotor. The computed results of the output characteristics and the dynamic behaviors of the system operated at the maximum power coefficient points show that Type-A, which has fine operating behavior to wind speed changes and can be compactly designed because of a shorter rotational shaft, is an effective way for self-controlled stand-alone small-scale systems.

  8. Minimum cost solution of wind–photovoltaic based stand-alone power systems for remote consumers

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Zafirakis, D.; Kavadias, K.

    2012-01-01

    Renewable energy sources (RES) based stand-alone systems employing either wind or solar power and energy storage comprise a reliable energy alternative, on top of conventional diesel-electric generator sets, commonly used by remote consumers. However, such systems usually imply the need for oversizing and considerable energy storage requirements leading to relatively high costs. On the other hand, hybrid configurations that may exploit both wind and solar potential of a given area may considerably reduce energy storage capacity and improve the economic performance of the system. In this context, an integrated techno-economic methodology for the evaluation of hybrid wind–photovoltaic stand-alone power systems is currently developed, aiming at the designation of optimum configurations for a typical remote consumer, using economic performance criteria. For the problem investigation, the developed evaluation model is applied to four representative areas of the Greek territory with different wind potential characteristics in order to obtain optimum configurations on the basis of minimum initial investment, 10-year and 20-year total cost. According to the results obtained, the proposed solution is favorably compared with all other stand-alone energy alternatives, reflecting the ability of hybrid systems to adjust even in areas where the local RES potential is not necessarily of high quality. - Highlights: ► Wind- and PV-stand alone systems often imply use of extreme battery capacity. ► Hybrid wind–PV systems may reduce energy storage requirements and associated costs. ► An optimization methodology is developed, based on economic performance criteria. ► Methodology is applied to four Greek regions of different wind potential. ► Results obtained reflect the hybrid solution's advantages over other alternatives.

  9. Structure Optimization of Stand-Alone Renewable Power Systems Based on Multi Object Function

    Directory of Open Access Journals (Sweden)

    Jae-Hoon Cho

    2016-08-01

    Full Text Available This paper presents a methodology for the size optimization of a stand-alone hybrid PV/wind/diesel/battery system while considering the following factors: total annual cost (TAC, loss of power supply probability (LPSP, and the fuel cost of the diesel generator required by the user. A new optimization algorithm and an object function (including a penalty method are also proposed; these assist with designing the best structure for a hybrid system satisfying the constraints. In hybrid energy system sources such as photovoltaic (PV, wind, diesel, and energy storage devices are connected as an electrical load supply. Because the power produced by PV and wind turbine sources is dependent on the variation of the resources (sun and wind and the load demand fluctuates, such a hybrid system must be able to satisfy the load requirements at any time and store the excess energy for use in deficit conditions. Therefore, reliability and cost are the two main criteria when designing a stand-alone hybrid system. Moreover, the operation of a diesel generator is important to achieve greater reliability. In this paper, TAC, LPSP, and the fuel cost of the diesel generator are considered as the objective variables and a hybrid teaching–learning-based optimization algorithm is proposed and used to choose the best structure of a stand-alone hybrid PV/wind/diesel/battery system. Simulation results from MATLAB support the effectiveness of the proposed method and confirm that it is more efficient than conventional methods.

  10. Simulation of stand alone PV systems; Dokuritsugata taiyoko hatsuden system no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, I.; Sakuta, K. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T. [Japan Quality Assurance Organization, Tokyo (Japan); Kurokawa, K. [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1997-11-25

    Studies are performed to develop a simulation program for a stand-alone photovoltaic power generation system equipped with a lead acid battery. In this stand-alone photovoltaic power generation system, the load is connected in shunt with the solar cell array output through the intermediary of a lead acid battery and inverter. The program is a model in which the solar cell model is built taking parallel resistance into account, and the temperature-dependence of the constants is described using approximations experimentally obtained by Solar Techno Center of JQA (Japan Quality Assurance Organization), Hamamatsu. Insolation data for the model is described using METPV compiled by Japan Weather Association, and load data is described using data actually measured at Shizuoka. This program is compared with the data of operation at Hamamatsu, and the result is almost satisfactory. Simulations are conducted at five typical locations in Japan using this program, and it is found that the array load matching correction factor is dependent on seasonal changes rather than locality, that the battery contribution rate does not change much throughout the year, and that it is not dependent on locality. 5 refs., 7 figs., 3 tabs.

  11. Optimization of stand-alone photovoltaic systems with hydrogen storage for total energy self-sufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lund, P D [Helsinki Univ. of Technology, Espoo (Finland). Dept. of Technical Physics

    1991-01-01

    A new method for optimization of stand-alone photovoltaic-hydrogen energy systems is presented. The methodology gives the optimum values for the solar array and hydrogen storage size for any given system configuration and geographical site. Sensitivity analyses have been performed to study the effect of subsystem efficiencies on the total system performance and sizing, and also to identify possibilities for further improvements. Optimum system configurations have also been derived. The results indicate that a solar-hydrogen energy system is a very promising potential alternative for low power applications requiring a total electricity self-sufficiency. (Author).

  12. Design and Operation Studies of A Stand-Alone PV Generation System

    DEFF Research Database (Denmark)

    Hu, Yanting; Chen, Zhe; Zhang, Donglai

    2013-01-01

    This paper discusses the modeling, design and operation of a PV powered stand-alone system, which includes a PV array, a battery bank, power electronic converters and the associated control system. The design considerations are analyzed and a design platform is presented. Furthermore the operation...... modes of the system are described. A power electronic system with the associated control scheme has been proposed and simulation models have been developed. Simulation studies have been conducted on an example system; the results have demonstrated the effectiveness of the presented methods....

  13. Design, building and testing of a stand alone fuel cell hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Segura, F.; Duran, E.; Andujar, J.M. [Department of Electronic, Computer Science and Automatic Engineering, University of Huelva (Spain)

    2009-08-01

    This paper designs, sizes, builds and tests a stand alone fuel cell hybrid system made up of a fuel cell stack and a battery bank. This system has been sized to supply a typical telecommunication load profile, but moreover, the system can supply other profiles. For this purpose, a modular low cost electronic load bank has been designed and built. This load bank allows the power demand to be chosen by selecting different solid state relays. Moreover, a virtual instrument based on NI Labview {sup registered} has been designed to select the load power demand from the computer. (author)

  14. Development of a microprocessor controller for stand-alone photovoltaic power systems

    Science.gov (United States)

    Millner, A. R.; Kaufman, D. L.

    1984-01-01

    A controller for stand-alone photovoltaic systems has been developed using a low power CMOS microprocessor. It performs battery state of charge estimation, array control, load management, instrumentation, automatic testing, and communications functions. Array control options are sequential subarray switching and maximum power control. A calculator keypad and LCD display provides manual control, fault diagnosis and digital multimeter functions. An RS-232 port provides data logging or remote control capability. A prototype 5 kW unit has been built and tested successfully. The controller is expected to be useful in village photovoltaic power systems, large solar water pumping installations, and other battery management applications.

  15. Energy management system for stand-alone diesel-wind-biomass microgrid with energy storage system

    International Nuclear Information System (INIS)

    Wang, Chengshan; Liu, Yixin; Li, Xialin; Guo, Li; Qiao, Lei; Lu, Hai

    2016-01-01

    An energy management system for stand-alone microgrid composed of diesel generators, wind turbine generator, biomass generator and an ESS (energy storage system) is proposed in this paper. Different operation objectives are achieved by a hierarchical control structure with different time scales. Firstly, the optimal schedules of the diesel generators, wind turbine generator, biomass generator and ESS are determined fifteen minutes ahead according to the super short-term forecast of load and wind speed in the optimal scheduling layer. Comprehensive analysis which takes the uncertainty of load and wind speed into account is conducted in this layer to minimize the operation cost of the system and ensure a desirable range of the state of charge of the ESS. Secondly, the operation points of each unit are regulated dynamically to guarantee real-time power balance and safety range of diesel generation in the real-time control layer, based on which the response capability when suffering significant forecast deviation and other emergency issues, e.g. sudden load-up can be improved. Finally, the effectiveness of the proposed energy management strategy is verified on an RT-Lab based real-time simulation platform, and the economic performances with different types of ESS are analyzed as well. - Highlights: • A hierarchical control strategy is proposed for a stand-alone microgrid. • The uncertainties of load and wind speed have been considered. • Better economic performance and high reliability of the system can be achieved. • The influences of different energy storage systems have been analyzed.

  16. Boost converter with combined control loop for a stand-alone photovoltaic battery charge system

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Thomsen, Ole Cornelius

    2013-01-01

    frequency avoids perturbations in the load being propagated to the photovoltaic panel and thus deviating the operating point. Linearization of the photovoltaic panel and converter state-space modeling is performed. In order to achieve stable operation under all operating conditions, the photovoltaic panel......The converter control scheme plays an important role in the performance of maximum power point tracking (MPPT) algorithms. In this paper, an input voltage control with double loop for a stand-alone photovoltaic system is designed and tested. The inner current control loop with high crossover...

  17. Feasibility and Optimal Design of a Stand-Alone Photovoltaic Energy System for the Orphanage

    Directory of Open Access Journals (Sweden)

    Vincent Anayochukwu Ani

    2014-01-01

    Full Text Available Access to electricity can have a positive psychological impact through a lessening of the sense of exclusion, and vulnerability often felt by the orphanages. This paper presented the simulation and optimization study of a stand-alone photovoltaic power system that produced the desired power needs of an orphanage. Solar resources for the design of the system were obtained from the National Aeronautics and Space Administration (NASA Surface Meteorology and Solar Energy website at a location of 6°51′N latitude and 7°35′E longitude, with annual average solar radiation of 4.92 kWh/m2/d. This study is based on modeling, simulation, and optimization of energy system in the orphanage. The patterns of load consumption within the orphanage were studied and suitably modeled for optimization. Hybrid Optimization Model for Electric Renewables (HOMER software was used to analyze and design the proposed stand-alone photovoltaic power system model. The model was designed to provide an optimal system configuration based on an hour-by-hour data for energy availability and demands. A detailed design, description, and expected performance of the system were presented in this paper.

  18. Robust Power Management Control for Stand-Alone Hybrid Power Generation System

    International Nuclear Information System (INIS)

    Kamal, Elkhatib; Adouane, Lounis; Aitouche, Abdel; Mohammed, Walaa

    2017-01-01

    This paper presents a new robust fuzzy control of energy management strategy for the stand-alone hybrid power systems. It consists of two levels named centralized fuzzy supervisory control which generates the power references for each decentralized robust fuzzy control. Hybrid power systems comprises: a photovoltaic panel and wind turbine as renewable sources, a micro turbine generator and a battery storage system. The proposed control strategy is able to satisfy the load requirements based on a fuzzy supervisor controller and manage power flows between the different energy sources and the storage unit by respecting the state of charge and the variation of wind speed and irradiance. Centralized controller is designed based on If-Then fuzzy rules to manage and optimize the hybrid power system production by generating the reference power for photovoltaic panel and wind turbine. Decentralized controller is based on the Takagi-Sugeno fuzzy model and permits us to stabilize each photovoltaic panel and wind turbine in presence of disturbances and parametric uncertainties and to optimize the tracking reference which is given by the centralized controller level. The sufficient conditions stability are formulated in the format of linear matrix inequalities using the Lyapunov stability theory. The effectiveness of the proposed Strategy is finally demonstrated through a SAHPS (stand-alone hybrid power systems) to illustrate the effectiveness of the overall proposed method. (paper)

  19. Fuzzy logic control of stand-alone photovoltaic system with battery storage

    Science.gov (United States)

    Lalouni, S.; Rekioua, D.; Rekioua, T.; Matagne, E.

    Photovoltaic energy has nowadays an increased importance in electrical power applications, since it is considered as an essentially inexhaustible and broadly available energy resource. However, the output power provided via the photovoltaic conversion process depends on solar irradiation and temperature. Therefore, to maximize the efficiency of the photovoltaic energy system, it is necessary to track the maximum power point of the PV array. The present paper proposes a maximum power point tracker (MPPT) method, based on fuzzy logic controller (FLC), applied to a stand-alone photovoltaic system. It uses a sampling measure of the PV array power and voltage then determines an optimal increment required to have the optimal operating voltage which permits maximum power tracking. This method carries high accuracy around the optimum point when compared to the conventional one. The stand-alone photovoltaic system used in this paper includes two bi-directional DC/DC converters and a lead-acid battery bank to overcome the scare periods. One converter works as an MPP tracker, while the other regulates the batteries state of charge and compensates the power deficit to provide a continuous delivery of energy to the load. The Obtained simulation results show the effectiveness of the proposed fuzzy logic controller.

  20. International market assessment of stand-alone photovoltaic power systems for cottage industry applications

    Science.gov (United States)

    Philippi, T. M.

    1981-01-01

    The final result of an international assessment of the market for stand-alone photovoltaic systems in cottage industry applications is reported. Nonindustrialized countries without centrally planned economies were considered. Cottage industries were defined as small rural manufacturers, employing less than 50 people, producing consumer and simple products. The data to support this analysis were obtained from secondary and expert sources in the U.S. and in-country field investigations of the Philippines and Mexico. The near-term market for photovoltaics for rural cottage industry applications appears to be limited to demonstration projects and pilot programs, based on an in-depth study of the nature of cottage industry, its role in the rural economy, the electric energy requirements of cottage industry, and a financial analysis of stand-alone photovoltaic systems as compared to their most viable competitor, diesel driven generators. Photovoltaics are shown to be a better long-term option only for very low power requirements. Some of these uses would include clay mixers, grinders, centrifuges, lathes, power saws and lighting of a workshop.

  1. International market assessment of stand-alone photovoltaic power systems for cottage industry applications

    Science.gov (United States)

    Philippi, T. M.

    1981-11-01

    The final result of an international assessment of the market for stand-alone photovoltaic systems in cottage industry applications is reported. Nonindustrialized countries without centrally planned economies were considered. Cottage industries were defined as small rural manufacturers, employing less than 50 people, producing consumer and simple products. The data to support this analysis were obtained from secondary and expert sources in the U.S. and in-country field investigations of the Philippines and Mexico. The near-term market for photovoltaics for rural cottage industry applications appears to be limited to demonstration projects and pilot programs, based on an in-depth study of the nature of cottage industry, its role in the rural economy, the electric energy requirements of cottage industry, and a financial analysis of stand-alone photovoltaic systems as compared to their most viable competitor, diesel driven generators. Photovoltaics are shown to be a better long-term option only for very low power requirements. Some of these uses would include clay mixers, grinders, centrifuges, lathes, power saws and lighting of a workshop.

  2. Power quality improvement of a stand-alone power system subjected to various disturbances

    Science.gov (United States)

    Lone, Shameem Ahmad; Mufti, Mairaj Ud-Din

    In wind-diesel stand-alone power systems, the disturbances like random nature of wind power, turbulent wind, sudden changes in load demand and the wind park disconnection effect continuously the system voltage and frequency. The satisfactory operation of such a system is not an easy task and the control design has to take in to account all these subtleties. For maintaining the power quality, generally, a short-term energy storage device is used. In this paper, the performance of a wind-diesel system associated with a superconducting magnetic energy storage (SMES) system is studied. The effect of installing SMES at wind park bus/load bus, on the system performance is investigated. To control the exchange of real and reactive powers between the SMES unit and the wind-diesel system, a control strategy based on fuzzy logic is proposed. The dynamic models of the hybrid power system for most common scenarios are developed and the results presented.

  3. Charactrization of a Li-ion battery based stand-alone a-Si photovoltaic system

    International Nuclear Information System (INIS)

    Hamid Vishkasougheh, Mehdi; Tunaboylu, Bahadir

    2014-01-01

    Highlights: • An Li-ion battery based stand-alone a-Si PV was designed. The system composed of three a-Si panels with an efficiency of 7% and 40 cells of LFP batteries. • Effects of solar radiation and environmental temperature for three cities, Istanbul, Ankara, and Adana, have been investigated on a-Si panels. • Using transition formulas BSPV outputs are predictable for any location out of standard test condition. - Abstract: The number of photovoltaic (PV) system installations is increasing rapidly. As more people learn about this versatile and often cost-effective power option, this trend will accelerate. This document presents a recommended design for a battery based stand-alone photovoltaic system (BSPV). BSPV system has the ability to be applied in different areas, including warning signals, lighting, refrigeration, communication, residential water pumping, remote sensing, and cathodic protection. The presented calculation method gives a proper idea for a system sizing technique. Based on application load, different scenarios are possible for designing a BSPV system. In this study, a battery based stand-alone system was designed. The electricity generation part is three a-Si panels, which are connected in parallel, and for the storage part LFP (lithium iron phosphate) battery was used. The high power LFP battery packs are 40 cells each 8S5P (configured 8 series 5 parallel). Each individual pack weighs 0.5 kg and is 25.6 V. In order to evaluate the efficiency of a-Si panels with respect to the temperature and the solar irradiation, cities of Istanbul, Ankara and Adana in Turkey were selected. Temperature and solar irradiation were gathered from reliable sources and by using translation equations, current and voltage output of panels were calculated. As a result of these calculations, current and energy outputs were computed by considering an average efficient solar irradiation time value per day in Turkey. The calculated power values were inserted to a

  4. Charactrization of a Li-ion battery based stand-alone a-Si photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Hamid Vishkasougheh, Mehdi, E-mail: mehdi.hamid2@gmail.com [Istanbul Sehir University, Kubakisi Caddesi, No: 27, Altunizade, Uskudar, Istanbul 34662 (Turkey); Tunaboylu, Bahadir [Istanbul Sehir University, Kubakisi Caddesi, No: 27, Altunizade, Uskudar, Istanbul 34662 (Turkey); Marmara Research Center, Materials Institute, PO Box 21, Gebze, Kocaeli 41470 (Turkey)

    2014-11-01

    Highlights: • An Li-ion battery based stand-alone a-Si PV was designed. The system composed of three a-Si panels with an efficiency of 7% and 40 cells of LFP batteries. • Effects of solar radiation and environmental temperature for three cities, Istanbul, Ankara, and Adana, have been investigated on a-Si panels. • Using transition formulas BSPV outputs are predictable for any location out of standard test condition. - Abstract: The number of photovoltaic (PV) system installations is increasing rapidly. As more people learn about this versatile and often cost-effective power option, this trend will accelerate. This document presents a recommended design for a battery based stand-alone photovoltaic system (BSPV). BSPV system has the ability to be applied in different areas, including warning signals, lighting, refrigeration, communication, residential water pumping, remote sensing, and cathodic protection. The presented calculation method gives a proper idea for a system sizing technique. Based on application load, different scenarios are possible for designing a BSPV system. In this study, a battery based stand-alone system was designed. The electricity generation part is three a-Si panels, which are connected in parallel, and for the storage part LFP (lithium iron phosphate) battery was used. The high power LFP battery packs are 40 cells each 8S5P (configured 8 series 5 parallel). Each individual pack weighs 0.5 kg and is 25.6 V. In order to evaluate the efficiency of a-Si panels with respect to the temperature and the solar irradiation, cities of Istanbul, Ankara and Adana in Turkey were selected. Temperature and solar irradiation were gathered from reliable sources and by using translation equations, current and voltage output of panels were calculated. As a result of these calculations, current and energy outputs were computed by considering an average efficient solar irradiation time value per day in Turkey. The calculated power values were inserted to a

  5. Loss-of-load probabilities for stand-alone photovoltaic systems

    International Nuclear Information System (INIS)

    Klein, S.A.; Beckman, W.A.

    1989-01-01

    A general method is presented for estimating the loss-of-load probability of stand-alone photovoltaic systems. The method was developed by correlating simulation results. The simulations were driven with synthetic radiation sequences having the same statistical significance as available historical data. The methods assumes a constant nighttime load and accounts for the distribution and persistence in daily solar radiation data. It is shown that the 10 year average performance of systems having loss-of-load probabilities less than about 0.01 can vary greatly from one ten year period to the next and thereby cannot be considered realistic performance estimates of a system during its lifetime. (author). 26 refs, 15 figs, 4 tabs

  6. Use of small stand-alone Internet nodes as a distributed control system

    Science.gov (United States)

    Goodwin, Robert W.; Kucera, Michael J.; Shea, Michael F.

    1994-12-01

    For several years, the standard model for accelerator control systems has been workstation consoles connected to VME local stations by a Local Area Network with analog and digital data being accessed via a field bus to custom I/O interface electronics. Commercially available hardware has now made it possible to implement a small stand-alone data acquisition station that combines the LAN connection, the computer, and the analog and digital I/O interface on a single board. This eliminates the complexity of a field bus and the associated proprietary I/O hardware. A minimum control system is one data acquisition station and a Macintosh or workstation console, both connected to the network; larger systems have more consoles and nodes. An implementation of this architecture is described along with performance and operational experience.

  7. JAERI Fuel Cleanup System (J-FCU) stand-alone tritium test at the TSTA

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Hayashi, Takumi; Inoue, Masahiko

    1993-03-01

    JAERI designed, fabricated, and installed the JAERI Fuel Cleanup System (J-FCU) as a subsystem of simulated fusion fuel loop at the TSTA. The main function of the J-FCU is to purify and to recover hydrogen isotopes from simulated plasma exhaust while exhausting tritium free impurities. After a lot of deuterium tests, a first tritium test of the J-FCU was performed with one gram of tritium at the TSTA on June 1991. Main purpose of this test was to evaluate the total integrity and function of the J-FCU system with a DT mixture. Through this test, the J-FCU was operated well and its function with tritium was demonstrated. This report describes the detail test results of the J-FCU first tritium test and discuss its functions by stand-alone mode. Residual tritium inventory of the J-FCU system was also discussed. (author)

  8. Integrated Three-Port DC-DC Converter for Photovoltaic (PV) Battery Stand-alone Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    of solar energy. Moreover, a novel transformer configuration enables variable turns ratio controlled by the phase between the two current excitations subjected to the primary windings, allowing a wider input/output range. 1 kW experimental prototype has been built to demonstrate a wellmanaged power flow......Several power sources such as PV solar arrays and battery are often used to manage the power flow for a photovoltaic (PV) based stand-alone power system due to the fluctuation nature of solar energy resource, and deliver a continuous power to the users in an appropriate form. Traditionally, three...... different single-input single-output (SISO) dc/dc converters would have been used. To reduce the cost and improve the power density of the system, an integrated three-port isolated dc/dc converter is proposed in this paper. It can realize all functions of the energy delivery due to the fluctuation nature...

  9. Optimal expansion planning of stand-alone systems with stochastic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hoese, Alejandro [Instituto de Energia Electrica (IEE), Universidad Nacional de San Juan, (Argentina)

    1997-12-31

    Stand-alone systems in the range of 1 kW - 10 MW are taking relevance in the new (global) liberal concept of energy market. State and private investors are becoming increasingly attention on the use of renewable for these systems, but it must be shown that these non-conventional solutions are competitive with the established conventional ones. The high investment costs and the technical and economic uncertainties coupled with the use of time-dependent energy sources are the mainly inhibiting factors for the decision agents to choose these systems instead of conventional ones. In the paper a new model for optimal expansion planning of hybrid stand-alone generating systems under consideration of uncertainties is presented. This model is at present in {sup d}evelopment state{sup .} Results already obtained in the first steps of this research are promising and some of them are here presented. [Espanol] Los sistemas autocontenidos en el rango de 1 Kw a 10 MW estan tomando importancia en el nuevo (global) concepto liberal del mercado de la energia. Inversionistas privados y del Estado estan poniendo mayor atencion en el uso de energias renovables para estos sistemas, pero debe mostrarse que estas soluciones no-convencionales son competitivas con las convencionales establecidas. Los altos costos de inversion y las incertidumbres tecnicas y economicas aunadamente con el uso de fuentes de energia dependientes del tiempo son los principales factores inhibidores de los factores de decision para escoger estos sistemas en lugar de los convencionales. En este articulo se presenta un nuevo modelo de planeacion de expansion optima de sistemas hibridos autocontenidos de generacion electrica bajo la consideracion de incertidumbres. Este modelo esta actualmente en {sup e}stado de desarrollo{sup .} Los resultados ya obtenidos en las primeras etapas de esta investigacion son prometedores y se presentan algunos de ellos.

  10. Optimal expansion planning of stand-alone systems with stochastic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hoese, Alejandro [Instituto de Energia Electrica (IEE), Universidad Nacional de San Juan, (Argentina)

    1998-12-31

    Stand-alone systems in the range of 1 kW - 10 MW are taking relevance in the new (global) liberal concept of energy market. State and private investors are becoming increasingly attention on the use of renewable for these systems, but it must be shown that these non-conventional solutions are competitive with the established conventional ones. The high investment costs and the technical and economic uncertainties coupled with the use of time-dependent energy sources are the mainly inhibiting factors for the decision agents to choose these systems instead of conventional ones. In the paper a new model for optimal expansion planning of hybrid stand-alone generating systems under consideration of uncertainties is presented. This model is at present in {sup d}evelopment state{sup .} Results already obtained in the first steps of this research are promising and some of them are here presented. [Espanol] Los sistemas autocontenidos en el rango de 1 Kw a 10 MW estan tomando importancia en el nuevo (global) concepto liberal del mercado de la energia. Inversionistas privados y del Estado estan poniendo mayor atencion en el uso de energias renovables para estos sistemas, pero debe mostrarse que estas soluciones no-convencionales son competitivas con las convencionales establecidas. Los altos costos de inversion y las incertidumbres tecnicas y economicas aunadamente con el uso de fuentes de energia dependientes del tiempo son los principales factores inhibidores de los factores de decision para escoger estos sistemas en lugar de los convencionales. En este articulo se presenta un nuevo modelo de planeacion de expansion optima de sistemas hibridos autocontenidos de generacion electrica bajo la consideracion de incertidumbres. Este modelo esta actualmente en {sup e}stado de desarrollo{sup .} Los resultados ya obtenidos en las primeras etapas de esta investigacion son prometedores y se presentan algunos de ellos.

  11. Solar pv fed stand-alone excitation system of a synchronous machine for reactive power generation

    Science.gov (United States)

    Sudhakar, N.; Jain, Siddhartha; Jyotheeswara Reddy, K.

    2017-11-01

    This paper presents a model of a stand-alone solar energy conversion system based on synchronous machine working as a synchronous condenser in overexcited state. The proposed model consists of a Synchronous Condenser, a DC/DC boost converter whose output is fed to the field of the SC. The boost converter is supplied by the modelled solar panel and a day time variable irradiance is fed to the panel during the simulation time. The model also has one alternate source of rechargeable batteries for the time when irradiance falls below a threshold value. Also the excess power produced when there is ample irradiance is divided in two parts and one is fed to the boost converter while other is utilized to recharge the batteries. A simulation is done in MATLAB-SIMULINK and the obtained results show the utility of such modelling for supplying reactive power is feasible.

  12. Stand-Alone Photovoltaic System Operation with Energy Management and Fault Tolerant

    International Nuclear Information System (INIS)

    Jmashidpour, Ehsan; Poure, Philippe; Gholipour, E.; Saadate, Shahrokh

    2017-01-01

    This paper presents a stand-alone photovoltaic (PV) system with a fault tolerant operation capability. An energy management method is provided to keep the balance between produced and consumed energy instantaneously. As the storage element, an Ultra-Capacitor (UC) pack is used for facing high frequency variation of the load/source, and batteries are in charge of slow load /source variations. A Maximum Power Point Tracking (MPPT) algorithm is applied to control the boost converter of the PV source to achieve the maximum power. In order to improve the micro-grid service continuity and reliability, a fast fault diagnosis method based on the converter current shape for PV source is applied. Finally, the validity of the proposed energy management and the fault diagnosis method is confirmed by the simulation and experimental results. (author)

  13. Simulation of stand alone PV system; Dokuritsugata taiyoko hatsuden system no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, H; Ogawa, H; Sekii, Y [Chiba Institute of Technology, Chiba (Japan); Tsuda, I; Nozaki, K [Electrotechnical Laboratory, Tsukuba (Japan); Kurokawa, K [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1996-10-27

    In order to evaluate the simulation results of a photovoltaic power generation system, an operation simulation was carried out using the actual measured data of a stand alone PV system in Miyakojima, Okinawa Prefecture, so as to make a comparison with the actual operation data. The electric power was supplied to 250 houses and primary/junior high schools in the surrounding villages, which had an average demand load of approximately 90kw and the maximum of approximately 200kw. The power was supplied through the PV power generation in the duration of the sunshine, with an excess power charged in storage batteries and then supplied from the batteries at night. The array capacity was made 750kWp, the output current and storage batteries being characteristic type with an actual efficiency curve used for the inverter. The weather data used were the actual inclined insolation quantity and the outside air temperature data for a period of one month of November. The power charged in excess of 100% in the batteries was termed as an overflow power. With the charging condition 30% or less, a diesel generator was run for a rated operation for one hour, the power of which was termed as a backup power. As a result, the simulation was found nearly in agreement with the actual measurements. 5 refs., 7 figs., 2 tabs.

  14. Optimization of the photovoltaic-hydrogen supply system of a stand-alone remote-telecom application

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Guillermo; Martinez, Graciano; Galvez, Jose L.; Cuevas, Raquel; Maellas, Jesus [National Institute for Aerospace Technology (INTA), Renewable Energy Department, Ctra. Ajalvir km 4, E-28850 Torrejon de Ardoz, Madrid (Spain); Gila, Raul; Bueno, Emilio [Polytechnical School - Alcala de Henares University, Electronics Department, Campus Universitario, Ctra. De Madrid-Barcelona Km 33.600, Alcala de Henares, Madrid (Spain)

    2009-07-15

    Hydrogen is considered as the optimal carrier for the surplus energy storage from renewable resources. Although hydrogen and its application in fuel cell is considered as a high-cost energy system, some cost-efficient solutions have been found for their use in stand-alone applications, which usually depend on the variability of renewable sources that have to be oversized in order to reduce their dependence on external energy sources. This paper shows the results from the simulation of several alternatives of introducing hydrogen technologies to increase the independence of a remote-telecom application fed by photovoltaic panels. Hydrogen is obtained by electrolysis and it is used in a fuel cell when the renewable energy source is not enough to maintain the stand-alone application. TRNSYS simulation environment has been used for evaluating the proposed alternatives. The results show that the best configuration option is that considering the use of hydrogen as a way to storage the surplus of radiation and the management system can vary the number of photovoltaic panels assigned to feed the hydrogen generation, the batteries or the telecom application. (author)

  15. Multi-objective analytical model for optimal sizing of stand-alone photovoltaic water pumping systems

    International Nuclear Information System (INIS)

    Olcan, Ceyda

    2015-01-01

    Highlights: • An analytical optimal sizing model is proposed for PV water pumping systems. • The objectives are chosen as deficiency of power supply and life-cycle costs. • The crop water requirements are estimated for a citrus tree yard in Antalya. • The optimal tilt angles are calculated for fixed, seasonal and monthly changes. • The sizing results showed the validity of the proposed analytical model. - Abstract: Stand-alone photovoltaic (PV) water pumping systems effectively use solar energy for irrigation purposes in remote areas. However the random variability and unpredictability of solar energy makes difficult the penetration of PV implementations and complicate the system design. An optimal sizing of these systems proves to be essential. This paper recommends a techno-economic optimization model to determine optimally the capacity of the components of PV water pumping system using a water storage tank. The proposed model is developed regarding the reliability and cost indicators, which are the deficiency of power supply probability and life-cycle costs, respectively. The novelty is that the proposed optimization model is analytically defined for two-objectives and it is able to find a compromise solution. The sizing of a stand-alone PV water pumping system comprises a detailed analysis of crop water requirements and optimal tilt angles. Besides the necessity of long solar radiation and temperature time series, the accurate forecasts of water supply needs have to be determined. The calculation of the optimal tilt angle for yearly, seasonally and monthly frequencies results in higher system efficiency. It is, therefore, suggested to change regularly the tilt angle in order to maximize solar energy output. The proposed optimal sizing model incorporates all these improvements and can accomplish a comprehensive optimization of PV water pumping systems. A case study is conducted considering the irrigation of citrus trees yard located in Antalya, Turkey

  16. Solar photovoltaic applications seminar: design, installation and operation of small, stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    1980-07-01

    This seminar material was developed primarily to provide solar photovoltaic (PV) applied engineering technology to the Federal community. An introduction to photoconductivity, semiconductors, and solar photovoltaic cells is included along with a demonstration of specific applications and application identification. The seminar details general systems design and incorporates most known information from industry, academia, and Government concerning small solar cell power system design engineering, presented in a practical and applied manner. Solar PV power system applications involve classical direct electrical energy conversion and electric power system analysis and synthesis. Presentations and examples involve a variety of disciplines including structural analysis, electric power and load analysis, reliability, sizing and optimization; and, installation, operation and maintenance. Four specific system designs are demonstrated: water pumping, domestic uses, navigational and aircraft aids, and telecommunications. All of the applications discussed are for small power requirement (under 2 kilowatts), stand-alone systems to be used in remote locations. Also presented are practical lessons gained from currently installed and operating systems, problems at sites and their resolution, a logical progression through each major phase of system acquisition, as well as thorough design reviews for each application.

  17. Approaches for developing a sizing method for stand-alone PV systems with variable demand

    Energy Technology Data Exchange (ETDEWEB)

    Posadillo, R. [Grupo de Investigacion en Energias y Recursos Renovables, Dpto. de Fisica Aplicada, E.P.S., Universidad de Cordoba, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Lopez Luque, R. [Grupo de Investigacion de Fisica para las Energias y Recursos Renovables, Dpto. de Fisica Aplicada. Edificio C2 Campus de Rabanales, 14071 Cordoba (Spain)

    2008-05-15

    Accurate sizing is one of the most important aspects to take into consideration when designing a stand-alone photovoltaic system (SAPV). Various methods, which differ in terms of their simplicity or reliability, have been developed for this purpose. Analytical methods, which seek functional relationships between variables of interest to the sizing problem, are one of these approaches. A series of rational considerations are presented in this paper with the aim of shedding light upon the basic principles and results of various sizing methods proposed by different authors. These considerations set the basis for a new analytical method that has been designed for systems with variable monthly energy demands. Following previous approaches, the method proposed is based on the concept of loss of load probability (LLP) - a parameter that is used to characterize system design. The method includes information on the standard deviation of loss of load probability ({sigma}{sub LLP}) and on two new parameters: annual number of system failures (f) and standard deviation of annual number of failures ({sigma}{sub f}). The method proves useful for sizing a PV system in a reliable manner and serves to explain the discrepancies found in the research on systems with LLP<10{sup -2}. We demonstrate that reliability depends not only on the sizing variables and on the distribution function of solar radiation, but on the minimum value as well, which in a given location and with a monthly average clearness index, achieves total solar radiation on the receiver surface. (author)

  18. Efficiency of hydrogen gas production in a stand-alone solar hydrogen system

    International Nuclear Information System (INIS)

    Singh, K.; Tamakloe, R.Y.

    2003-01-01

    Many photovoltaic systems operate in a decentralised electricity producing system, or stand-alone mode and the total energy demand is met by the output of the photovoltaic array. The output of the photovoltaic system fluctuates and is unpredictable for many applications making some forms of energy storage system necessary. The role of storage medium is to store the excess energy produced by the photovoltaic arry, to absorb momentary power peaks and to supply energy during sunless periods. One of the storage modes is the use of electrochemical techniques, with batteries and water electrolysis as the most important examples. The present study includes three main parts: the first one is the hydrogen production form the electrolysis of water depending on the DC output current of the photovoltaic (PV) energy source and the charging of the battery. The second part presents the influence of various parameters on the efficiency of hydrogen gas production. The final part includes simulation studies with focus on solar hydrogen efficiency under the influence of various physical and chemical parameters. For a 50W panel-battery-electrolyser system, the dependence of volume of hydrogen gas on voltage, current and power yielded a maximum efficiency of 13.6% (author)

  19. Use of Super-Capacitor to Enhance Charging Performance of Stand-Alone Solar PV System

    KAUST Repository

    Huang, B. J.

    2011-01-01

    Introduction: The battery charging performance in a stand-alone solar PV system affects the PV system efficiency and the load operating time. The New Energy Center of National Taiwan University has been devoted to the development of a PWM charging technique to continue charging the lead-acid battery after the overcharge point to increase the battery storage capacity by more than 10%. The present study intends to use the super-capacitor to further increase the charge capacity before the overcharge point of the battery. The super-capacitor is connected in parallel to the lead-acid battery. This will reduce the overall charging impedance during the charge and increase the charging current, especially in sunny weather. A system dynamics model of the lead-acid battery and super-capacitor was derived and the control system simulation was carried out to predict the charging performance for various weathers. It shows that the overall battery impedance decreases and charging power increases with increasing solar radiation. An outdoor comparative test for two identical PV systems with and without supercapacitor was carried out. The use of super-capacitor is shown to be able to increase the lead-acid charging capacity by more than 25% at sunny weather and 10% in cloudy weather. © Springer-Verlag Berlin Heidelberg 2011.

  20. Battery Storage Technologies for Electrical Applications: Impact in Stand-Alone Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Daniel Akinyele

    2017-11-01

    Full Text Available Batteries are promising storage technologies for stationary applications because of their maturity, and the ease with which they are designed and installed compared to other technologies. However, they pose threats to the environment and human health. Several studies have discussed the various battery technologies and applications, but evaluating the environmental impact of batteries in electrical systems remains a gap that requires concerted research efforts. This study first presents an overview of batteries and compares their technical properties such as the cycle life, power and energy densities, efficiencies and the costs. It proposes an optimal battery technology sizing and selection strategy, and then assesses the environmental impact of batteries in a typical renewable energy application by using a stand-alone photovoltaic (PV system as a case study. The greenhouse gas (GHG impact of the batteries is evaluated based on the life cycle emission rate parameter. Results reveal that the battery has a significant impact in the energy system, with a GHG impact of about 36–68% in a 1.5 kW PV system for different locations. The paper discusses new batteries, strategies to minimize battery impact and provides insights into the selection of batteries with improved cycling capacity, higher lifespan and lower cost that can achieve lower environmental impacts for future applications.

  1. Optimal sizing method for constituent elements of stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Hirotada; Oi, Yoichi [Hokuriku Electric Power Co., Inc. Toyama (Japan)

    1988-12-25

    The purpose of the report was to calculate the optimal volume of constituent elements of stand-alone photovoltaic power systems, based on the distribution of global radiation on an inclined surface (herein-after called flux of solar radiation), which had been previously measured, and the size of load to be supplied. The least power generation cost was calculated, supposing that setting load was 176kWh/month and the loss of load probability (LOLP) was 1%, by using actual amount of solar radiation in May 1985. The cost was divided into two components: one was proportionate to the size of solar cell, and the other was in proportion to the battery volume. And then, the cost of twenty-year operation(TLC) was calculated. The size of array and the battery volume, which minimize the cost, can be determined when TLC is differentiate. Since auxiliary power source is not attached to this system, it is necessary to restrict the load in order to meet the electric power shortage. In case of the cost at construction in 1984, a standard model indicating the least power generation cost is a photovoltaic system with the array size of A=49.0m{sup 2} and the battery volume of Q=568(Ah). 4 refs., 9 figs., 10 tabs.

  2. Comparative analysis of distributed MPPT controllers for partially shaded stand alone photovoltaic systems

    International Nuclear Information System (INIS)

    Muthuramalingam, M.; Manoharan, P.S.

    2014-01-01

    Highlights: • Analyzes the performance of ANN and ANFIS MPPT algorithms by stand alone PV system. • ISSBC with ANFIS can provide the overall efficiency higher than ANN. • CHBMLI integrate with SHE ANN modulation technique improve output voltage quality. • Simulation and hardware results show the ANFIS algorithm efficient than ANN algorithm. - Abstract: This paper presents a unique combination of an interleaved soft switched boost converter (ISSBC) run by a set of two photovoltaic panel (PV) with a distributed MPPT, suitable to guarantee MPPT even under partial shadowed conditions, managed by an adaptive neuro fuzzy inference system trained by the training data derived from a particle swarm optimization (PSO–ANFIS) unit. The ISSBC is followed by a, single phase cascaded H bridge five-level inverter (CHI) driven by the individual DC outputs of the ISSBC, with selective harmonic elimination scheme to eliminate typically the seventh order harmonics. A comparison of different intelligent distributed maximum power point tracking (MPPT) algorithms for photovoltaic (PV) system under partial shadow conditions is carried out. The use of the ISSBC guarantees mitigation of ripple and it is meant to handle higher currents with minimal switching losses. Simulation was carried out in the Matlab Simulink environment and an experimental verification with a scaled down model validated the proposed scheme. It has been thus established, by both simulation and experimental verification, that the PSO–ANFIS model of distributed MPPT scheme of control outperforms other schemes of control for MPPT

  3. Study on the optimization of stand-alone type photovoltaic systems. 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Man Geun; Song, Jin Soo; Kim, Boo ho; Park, I June; Jung, Meung Woong; Yoo, Kyun Joung; Kim, Hong Woo [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The objectives of this study are to make a maximization of the operating efficiency of photovoltaic power systems, to improve stand- align PV systems design, technical operation and system analysis, and to promote technical cooperation of mutual interest in the area of IEA/PVPS program. This study aims to investigating the problems of applied photovoltaic power systems currently in operation to improve a system design, seeking remedies of individual PVPS applications to improve the system efficiency and reliability and to raise the system economics, and reporting the international movements of PV system dissemination and technical cooperation for developing countries. For the purpose of this works 1) Investigations of applications of existing photovoltaic power systems: - Photovoltaic electric sources used for expressway lamps - Optimum design of solar light with low pressure sodium lamps under 8 hours lighting a day at night by program-able electronic timer. 2) Comparative analyses of Marado PV system and propose a new reliable PV-diesel hybrid system and high efficiency operations. 3) Overall review of Hahwado 60 KWp PV system extending from 25 KWp and the remote monitoring systems for measurement of its operating results. 4) Introduction of IEA/PVPS international cooperating program, especially in task III for stand- alone PV systems and isolated islands and Exco meeting. As results, investigative findings of PVPS currently in operation and the work for improvement - Propose a prescription of Marado PV systems being blocked up by explosion of electrical demands from residence, parallel operational dual inverter with a big capacity. - There are shortage of solar generated power due to shortage of solar cell capacity that results in an increased operating time of diesel generator. Hence the insolation capacity of solar cell per household is continuously increased from the 0.5 KWp to 2 KWp in Hanwado island electrification.

  4. Optimum capacity determination of stand-alone hybrid generation system considering cost and reliability

    International Nuclear Information System (INIS)

    Chen, Hung-Cheng

    2013-01-01

    Highlights: ► This paper presents a methodology for the installation capacity optimization. ► Hybrid generation system is optimized by application of adaptive genetic algorithm. ► A cost investigation is made under various conditions and component characteristics. ► The optimization scheme is validated to meet the annual power load demand. -- Abstract: The aim of this work is to present an optimization methodology for the installation capacity of a stand-alone hybrid generation system, taking into consideration the cost and reliability. Firstly, on the basis of derived steady state models of a wind generator (WG), a photovoltaic array (PV), a battery and an inverter, the hybrid generation system is modeled for the purpose of capacity optimization. Secondly, the power system is analyzed for determining both the system structure and the operation control strategy. Thirdly, according to hourly weather database of wind speed, temperature and solar irradiation, annual power generation capacity is estimated for the system match design in order that an annual power load demand can be met. The capacity determination of a hybrid generation system becomes complicated as a result of the uncertainty in the renewable energy together with load demand and the nonlinearity of system components. Aimed at the power system reliability and the cost minimization, the capacity of a hybrid generation system is optimized by application of an adaptive genetic algorithm (AGA) to individual power generation units. A total cost investigation is made under various conditions, such as wind generator power curves, battery discharge depth and the loss of load probability (LOLP). At the end of this work, the capacity of a hybrid generation system is optimized at two installation sites, namely the offshore Orchid Island and Wuchi in Taiwan. The optimization scheme is validated to optimize power capacities of a photovoltaic array, a battery and a wind turbine generator with a relative

  5. Stand-Alone Solar Organic Rankine Cycle Water Pumping System and Its Economic Viability in Nepal

    Directory of Open Access Journals (Sweden)

    Suresh Baral

    2015-12-01

    Full Text Available The current study presents the concept of a stand-alone solar organic Rankine cycle (ORC water pumping system for rural Nepalese areas. Experimental results for this technology are presented based on a prototype. The economic viability of the system was assessed based on solar radiation data of different Nepalese geographic locations. The mechanical power produced by the solar ORC is coupled with a water pumping system for various applications, such as drinking and irrigation. The thermal efficiency of the system was found to be 8% with an operating temperature of 120 °C. The hot water produced by the unit has a temperature of 40 °C. Economic assessment was done for 1-kW and 5-kW solar ORC water pumping systems. These systems use different types of solar collectors: a parabolic trough collector (PTC and an evacuated tube collector (ETC. The economic analysis showed that the costs of water are $2.47/m3 (highest and $1.86/m3 (lowest for the 1-kW system and a 150-m pumping head. In addition, the cost of water is reduced when the size of the system is increased and the pumping head is reduced. The minimum volumes of water pumped are 2190 m3 and 11,100 m3 yearly for 1 kW and 5 kW, respectively. The payback period is eight years with a profitability index of 1.6. The system is highly feasible and promising in the context of Nepal.

  6. Hydrogen-based energy storage unit for stand alone PV systems

    International Nuclear Information System (INIS)

    Labbe, J.

    2006-12-01

    Stand alone systems supplied only by a photovoltaic generator need an energy storage unit to be fully self sufficient. Lead acid batteries are commonly used to store energy because of their low cost, despite several operational constraints. A hydrogen-based energy storage unit (HESU) could be another candidate, including an electrolyser, a fuel cell and a hydrogen tank. However many efforts still need to be carried out for this technology to reach an industrial stage. In particular, market outlets must be clearly identified. The study of small stationary applications (few kW) is performed by numerical simulations. A simulator is developed in the Matlab/Simulink environment. It is mainly composed of a photovoltaic field and a storage unit (lead acid batteries, HESU, or hybrid storage HESU/batteries). The system component sizing is achieved in order to ensure the complete system autonomy over a whole year of operation. The simulator is tested with 160 load profiles (1 kW as a yearly mean value) and three locations (Algeria, France and Norway). Two coefficients are set in order to quantify the correlation between the power consumption of the end user and the renewable resource availability at both daily and yearly scales. Among the tested cases, a limit value of the yearly correlation coefficient came out, enabling to recommend the use of the most adapted storage to a considered case. There are cases for which using HESU instead of lead acid batteries can increase the system efficiency, decrease the size of the photovoltaic field and improve the exploitation of the renewable resource. In addition, hybridization of HESU with batteries always leads to system enhancements regarding its sizing and performance, with an efficiency increase by 10 to 40 % depending on the considered location. The good agreement between the simulation data and field data gathered on real systems enabled the validation of the models used in this study. (author)

  7. Probabilistic modelling and analysis of stand-alone hybrid power systems

    International Nuclear Information System (INIS)

    Lujano-Rojas, Juan M.; Dufo-López, Rodolfo; Bernal-Agustín, José L.

    2013-01-01

    As a part of the Hybrid Intelligent Algorithm, a model based on an ANN (artificial neural network) has been proposed in this paper to represent hybrid system behaviour considering the uncertainty related to wind speed and solar radiation, battery bank lifetime, and fuel prices. The Hybrid Intelligent Algorithm suggests a combination of probabilistic analysis based on a Monte Carlo simulation approach and artificial neural network training embedded in a genetic algorithm optimisation model. The installation of a typical hybrid system was analysed. Probabilistic analysis was used to generate an input–output dataset of 519 samples that was later used to train the ANNs to reduce the computational effort required. The generalisation ability of the ANNs was measured in terms of RMSE (Root Mean Square Error), MBE (Mean Bias Error), MAE (Mean Absolute Error), and R-squared estimators using another data group of 200 samples. The results obtained from the estimation of the expected energy not supplied, the probability of a determined reliability level, and the estimation of expected value of net present cost show that the presented model is able to represent the main characteristics of a typical hybrid power system under uncertain operating conditions. - Highlights: • This paper presents a probabilistic model for stand-alone hybrid power system. • The model considers the main sources of uncertainty related to renewable resources. • The Hybrid Intelligent Algorithm has been applied to represent hybrid system behaviour. • The installation of a typical hybrid system was analysed. • The results obtained from the study case validate the presented model

  8. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    Science.gov (United States)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  9. Feasibility study and energy conversion analysis of stand-alone hybrid renewable energy system

    International Nuclear Information System (INIS)

    Baghdadi, Fazia; Mohammedi, Kamal; Diaf, Said; Behar, Omar

    2015-01-01

    Highlights: • Hybrid stand-alone wind–solar–fossil power system is analyzed. • Measurement data are used to evaluate system performance. • The proposed system can generate about 70% from renewables. • Such a hybrid plant is very promising for remote regions in Algeria. - Abstract: There is a great interest in the development of renewable power technologies in Algeria, and more particularly hybrid concept. The present paper has investigated the performance of hybrid PV–Wind–Diesel–Battery configuration based on hourly measurements of Adrar climate (southern Algeria). Data of global solar radiation, ambient temperature and wind speed for a period of one year have been used. Firstly, the proposed hybrid system has been optimized by means of HOMER software. The optimization process has been carried out taking into account renewable resources potential and energy demand; while maximizing renewable electricity use and fuel saving are the purpose. In the second step, a mathematical model has been developed to ensure efficient energy management on the basis of various operation strategies. The analysis has shown that renewable energy system (PV–Wind) is able to supply about 70% of the demand. Wind power has ranked first with 43% of the annual total electricity production followed by diesel generator (with 31%) while the remaining fraction is being to PV panels. In this context, 69% of the fossil fuel can be saved when using the proposed hybrid configuration instead of the diesel generators that are currently installed in most remote regions in Algeria. Such a concept is very promising to meet the focus of renewable energy program announced in 2011.

  10. Stand-Alone Photovoltaic System Assessment in Warmer Urban Areas in Mexico

    Directory of Open Access Journals (Sweden)

    Alberto-Jesus Perea-Moreno

    2018-01-01

    Full Text Available The aim of this study is to examine the possibility of using a stand-alone photovoltaic system (SAPVS for electricity generation in urban areas in Southern Mexico. In Mexico, an urban area is defined as an area where more than 2500 inhabitants live. Due to constant migration from the countryside to the cities, the number of inhabitants of urban localities has been increasing. Global horizontal irradiation (GHI data were recorded every 10 min during 2014–2016 in Coatzacoalcos in the state of Veracruz located on 18°08′09″ N and 94°27′48″ W. In this study, batteries represented 77% of the total cost, 12 PV panels of 310 W could export 5.41 MWh to the grid, and an inverter with an integrated controller and charger was selected, which decreased the initial cost. The city of Coatzacoalcos was chosen because the average annual temperature is 28°, with an average relative humidity of 75% and an average irradiance of 5.3 kWh/m2/day. An emission factor 0.505 tCO2/MWh of greenhouse gases (GHG were obtained, based on the power system, the reduction of net annual GHG would be 11 tCO2 and a financial revenue of 36.951 × 103 $/tCO2 would be obtained. Financial parameters such as a 36.3% Internal Rate Return (IRR and 3.4 years payback show the financial viability of this investment. SAPVSs in urban areas in Mexico could be a benefit as long as housing has a high consumption of electricity.

  11. An improved synchronous reference frame phase-locked loop for stand-alone variable speed constant frequency power generation systems

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Ke, Longzhang

    2017-01-01

    The phase-locked loop (PLL) based on conventional synchronous reference frame, i.e. dqPLL, is usually employed in grid-connected variable speed constant frequency (VSCF) power generation systems (PGSs). However, the voltage amplitude drop of stand-alone PGSs is often greater than that of the grid...

  12. Analyzing grid extension and stand-alone photovoltaic systems for the cost-effective electrification of Kenya

    NARCIS (Netherlands)

    Zeyringer, Marianne; Pachauri, Shonali; Schmid, Erwin; Schmidt, Johannes; Worrell, Ernst|info:eu-repo/dai/nl/106856715; Morawetz, Ulrich B.

    2015-01-01

    The declaration of 2014-2024 as the Decade of Sustainable Energy for All has catalyzed actions towards achieving universal electricity access. The high costs of building electric infrastructure are a major impediment to improved access, making stand-alone photovoltaic (PV) systems an attractive

  13. A Low-Power Wearable Stand-Alone Tongue Drive System for People With Severe Disabilities.

    Science.gov (United States)

    Jafari, Ali; Buswell, Nathanael; Ghovanloo, Maysam; Mohsenin, Tinoosh

    2018-02-01

    This paper presents a low-power stand-alone tongue drive system (sTDS) used for individuals with severe disabilities to potentially control their environment such as computer, smartphone, and wheelchair using their voluntary tongue movements. A low-power local processor is proposed, which can perform signal processing to convert raw magnetic sensor signals to user-defined commands, on the sTDS wearable headset, rather than sending all raw data out to a PC or smartphone. The proposed sTDS significantly reduces the transmitter power consumption and subsequently increases the battery life. Assuming the sTDS user issues one command every 20 ms, the proposed local processor reduces the data volume that needs to be wirelessly transmitted by a factor of 64, from 9.6 to 0.15 kb/s. The proposed processor consists of three main blocks: serial peripheral interface bus for receiving raw data from magnetic sensors, external magnetic interference attenuation to attenuate external magnetic field from the raw magnetic signal, and a machine learning classifier for command detection. A proof-of-concept prototype sTDS has been implemented with a low-power IGLOO-nano field programmable gate array (FPGA), bluetooth low energy, battery and magnetic sensors on a headset, and tested. At clock frequency of 20 MHz, the processor takes 6.6 s and consumes 27 nJ for detecting a command with a detection accuracy of 96.9%. To further reduce power consumption, an application-specified integrated circuit processor for the sTDS is implemented at the postlayout level in 65-nm CMOS technology with 1-V power supply, and it consumes 0.43 mW, which is 10 lower than FPGA power consumption and occupies an area of only 0.016 mm.

  14. Solar Charged Stand Alone Inverter

    OpenAIRE

    M.Vasugi; Prof R.Jayaraman

    2014-01-01

    This paper deals with solar powered stand alone inverter which converts the variable dc output of a photovoltaic solar panel into ac that can be fed to loads. Stand alone inverters are used in systems where the inverter get its energy from batteries charged by photo voltaic arrays. A charge controller limits the rate at which electric current is added to or drawn from electric batteries. This charge discharge controller is needed to prevent the battery from being overcharged o...

  15. Modeling, design and analysis of a stand-alone hybrid power generation system using solar/urine

    International Nuclear Information System (INIS)

    Wu, Wei; Zhou, Ya-Yan; Lin, Mu-Hsuan; Hwang, Jenn-Jiang

    2013-01-01

    Highlights: • The stand-alone hybrid power system is presented. • The urine-to-hydrogen processor is proposed. • Scenario analysis of the hybrid power dispatching and the urine/solar demands is investigated. • The design, modeling and optimization of the hybrid power system is addressed by Aspen Plus and Matlab. - Abstract: The urine turned to hydrogen as an energy conversion process is integrated into a stand-alone hybrid (PV/FC/battery) power generation system. The optimization and simulation of a new urine-to-hydrogen processor is evaluated in Aspen Plus environment. In our approach, the PV generator aims to reduce urine consumption and the lithium-ion battery can compensate the power gap due to the fuel processing delay. Based on prescribed patterns of solar irradiation and the daily load demand of a 30-persons classroom, scenario analyses of the hybrid power dispatching and operational feasibility is addressed

  16. Hierarchical energy management system for stand-alone hybrid system based on generation costs and cascade control

    International Nuclear Information System (INIS)

    Torreglosa, J.P.; García, P.; Fernández, L.M.; Jurado, F.

    2014-01-01

    Highlights: • We present an energy management system for a stand-alone WT/PV/hydrogen/battery hybrid system. • Hierarchical control composed by master and slave control strategies. • Control assures reliable electricity support for stand-alone applications subject to technical and economic criteria. - Abstract: This paper presents an energy management system (EMS) for stand-alone hybrid systems composed by photovoltaic (PV) solar panels and a wind turbine (WT) as primary energy sources and two energy storage systems, which are a hydrogen system and a battery. The hydrogen system is composed of fuel cell (FC), electrolyzer and hydrogen storage tank. The EMS is a hierarchical control composed by a master control strategy and a slave control strategy. On the one hand, the master control generates the reference powers to meet several premises (such as to satisfy the load power demand, and to maintain the hydrogen tank level and the state of charge (SOC) of the battery between their target margins), taking also into account economic aspects to discriminate between using the battery or hydrogen system. On the other hand, the slave control modifies the reference powers generated by the master control according to the energy sources dynamic limitations, and maintains the DC bus voltage at its reference value. The models, implemented in MATLAB-Simulink environment, have been developed from commercially available components. To check the viability of the proposed EMS, two kinds of simulations were carried out: (1) A long-term simulation of 25 years (expected lifetime of the system) with a sample time of one hour to validate the master control of the EMS; and (2) A short-term simulation with sudden net power variations to validate the slave control of the EMS

  17. Control strategy of wind turbine based on permanent magnet synchronous generator and energy storage for stand-alone systems

    DEFF Research Database (Denmark)

    Deng, Fujin; Liu, Dong; Chen, Zhe

    2017-01-01

    This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system. An energy storage system(ESS) including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power...... converter through the power electronics interface. Wind is the primary power source of the system, the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system, respectively. In this paper, a control strategy is proposed...... for the operation of this variable speed wind turbine in a stand-alone system, where the generator-side converter and the ESS operate together to meet the demand of the loads. This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full...

  18. Optimum autonomous stand-alone photovoltaic system design on the basis of energy pay-back analysis

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Zafirakis, D.; Kondili, E.

    2009-01-01

    Stand-alone photovoltaic (PV) systems comprise one of the most promising electrification solutions for covering the demand of remote consumers. However, such systems are strongly questioned due to extreme life-cycle (LC) energy requirements. For similar installations to be considered as environmentally sustainable, their LC energy content must be compensated by the respective useful energy production, i.e. their energy pay-back period (EPBP) should be found less than their service period. In this context, an optimum sizing methodology is currently developed, based on the criterion of minimum embodied energy. Various energy autonomous stand-alone PV-lead-acid battery systems are examined and two different cases are investigated; a high solar potential area and a medium solar potential area. By considering that the PV-battery (PV-Bat) system's useful energy production is equal to the remote consumer's electricity consumption, optimum cadmium telluride (CdTe) based systems yield the minimum EPBP (15 years). If achieving to exploit the net PV energy production however, the EPBP is found less than 20 years for all PV types. Finally, the most interesting finding concerns the fact that in all cases examined the contribution of the battery component exceeds 27% of the system LC energy requirements, reflecting the difference between grid-connected and stand-alone configurations.

  19. Enhancement of a stand-alone photovoltaic system's performance: Reduction of soft and hard shading

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, Lisa A.; El Chaar, Lana [Petroleum Institute, Electrical Engineering Department, P.O. Box 2533, Abu Dhabi (United Arab Emirates)

    2011-04-15

    A stand-alone photovoltaic (PV) system is the most promising solution to supply electric power to meet energy demand in isolated locations. This technology can offer an interesting alternative to other currently existing sources of energy. Due to space constraint in the remote offshore oil and gas industry, a stand-alone system is used for cathodic protection, telemetry and valve control. However in such an environment, dust accumulation and bird droppings have been critical issues to the operation of off-grid solar devices. These factors do not only reduce the available power of the modules but also makes the cost of solar devices ineffective since cleaning, especially on well-head towers, is very expensive due to the location. Hence this paper presents two technical solutions that have shown promising results in reducing the impact of these factors. (author)

  20. prfectBLAST: a platform-independent portable front end for the command terminal BLAST+ stand-alone suite.

    Science.gov (United States)

    Santiago-Sotelo, Perfecto; Ramirez-Prado, Jorge Humberto

    2012-11-01

    prfectBLAST is a multiplatform graphical user interface (GUI) for the stand-alone BLAST+ suite of applications. It allows researchers to do nucleotide or amino acid sequence similarity searches against public (or user-customized) databases that are locally stored. It does not require any dependencies or installation and can be used from a portable flash drive. prfectBLAST is implemented in Java version 6 (SUN) and runs on all platforms that support Java and for which National Center for Biotechnology Information has made available stand-alone BLAST executables, including MS Windows, Mac OS X, and Linux. It is free and open source software, made available under the GNU General Public License version 3 (GPLv3) and can be downloaded at www.cicy.mx/sitios/jramirez or http://code.google.com/p/prfectblast/.

  1. New control strategy of stand-alone brushless doubly-fed induction generator for supplying unbalanced loads in ship shaft power generation system

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The ship shaft power generation system based on a stand-alone brushless doubly-fed induction generator (BDFIG) have demonstrated excellent saving-energy performance. This paper presents a new control scheme of the stand-alone BDFIG for supplying unbalanced loads in the ship shaft power generation...

  2. Control of a Stand-Alone Variable Speed Wind Energy Supply System

    Directory of Open Access Journals (Sweden)

    Mohamed M. Hamada

    2013-04-01

    Full Text Available This paper presents a simple control strategy for the operation of a variable speed stand-alone wind turbine with a permanent magnet synchronous generator (PMSG. The PMSG is connected to a three phase resistive load through a switch mode rectifier and a voltage source inverter. Control of the generator side converter is used to achieve maximum power extraction from the available wind power. Control of the DC-DC bidirectional buck-boost converter, which is connected between batteries bank and DC-link voltage, is used to maintain the DC-link voltage at a constant value. It is also used to make the batteries bank stores the surplus of wind energy and supplies this energy to the load during a wind power shortage. The load side voltage source inverter uses a relatively complex vector control scheme to control the output load voltage in terms of amplitude and frequency. The control strategy works under wind speed variation as well as with variable load. Extensive simulation results have been performed using MATLAB/SIMULINK.

  3. Efficiency of the hybrid solar-wind systems for electricity supply to the stand-alone sites

    International Nuclear Information System (INIS)

    Abdullaev, D.A.; Isaev, R.I.

    2000-01-01

    The features of stand-alone sites and principles of their electricity supply is described there is going observation of the works about conditions of production and efficiency of using autonomy wind turbines and photovoltaics. Their unsufficiency is estimated. The advantages of hybrid systems and their realization schemes is described. The advantage of hybrid solar-wind Battery system (HSWBS) on the basis of own researches and the facts of other authors are given. The conception overall discounting cost is developed on HSWBS case. (Author)

  4. Evaluation of a proper controller performance for maximum-power point tracking of a stand-alone PV system

    Energy Technology Data Exchange (ETDEWEB)

    Nafeh, A.E.-S.A.; Fahmy, F.H. [Electronics Research Institute, Cairo (Egypt); El-Zahab, E.M.A. [Cairo University, Giza (Egypt). Faculty of Engineering

    2003-02-01

    In this paper the implementation of a suggested stand-alone PV system, for maximum-power point tracking (MPPT), is carried out. Also, this paper presents a comparative study, through experimental work, between the conventional PI controller and the fuzzy logic controller (FLC) under different atmospheric conditions. The implemented system with both the PI controller and the FLC gives a good maximum-power operation of the PV array, but the tracking capability for different optimum operating points is better and faster for the case of using the FLC compared to the case of using the PI controller. (author)

  5. Economic and Environmental Assessment of a Renewable Stand-Alone Energy Supply System Using Multi-objective Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dohyun; Han, Seulki; Kim, Jiyong Kim [Incheon National University, Incheon (Korea, Republic of)

    2017-06-15

    This study aims to propose a new optimization-based approach for design and analysis of the stand-alone hybrid energy supply system using renewable energy sources (RES). In the energy supply system, we include multiple energy production technologies such as Photovoltaics (PV), Wind turbine, and fossil-fuel-based AC generator along with different types of energy storage and conversion technologies such as battery and inverter. We then select six different regions of Korea to represent various characteristics of different RES potentials and demand profiles. We finally designed and analyzed the optimal RES stand-alone energy supply system in the selected regions using multiobjective optimization (MOOP) technique, which includes two objective functions: the minimum cost and the minimum CO{sub 2} emission. In addition, we discussed the feasibility and expecting benefits of the systems by comparing to conventional systems of Korea. As a result, the region of the highest RES potential showed the possibility to remarkably reduce CO{sub 2} emissions compared to the conventional system. Besides, the levelized cost of electricity (LCOE) of the RES-based energy system is identified to be slightly higher than conventional energy system: 0.35 and 0.46 $/kWh, respectively. However, the total life-cycle emission of CO{sub 2} (LCECO{sub 2}) can be reduced up to 470 gCO{sub 2}/kWh from 490 gCO{sub 2}/kWh of the conventional systems.

  6. A Control Approach and Supplementary Controllers for a Stand-Alone System with Predominance of Wind Generation

    Directory of Open Access Journals (Sweden)

    Tiago Lukasievicz

    2018-02-01

    Full Text Available This paper proposes a control approach and supplementary controllers for the operation of a hybrid stand-alone system composed of a wind generation unit and a conventional generation unit based on synchronous generator (CGU. The proposed controllers allow the islanded or isolated operation of small power systems with predominance of wind generation. As an advantage and a paradigm shift, the DC-link voltage of the wind unit is controlled by means of a conventional synchronous generator connected to the AC grid of the system. Two supplementary controllers, added to a diesel generator (DIG and to a DC dump load (DL, are proposed to control the DC-link voltage. The wind generation unit operates in V-f control mode and the DIG operates in PQ control mode, which allows the stand-alone system to operate either in wind-diesel (WD mode or in wind-only (WO mode. The strong influence of the wind turbine speed variations in the DC-link voltage is mitigated by a low-pass filter added to the speed control loop of the wind turbine. The proposed control approach does not require the use battery bank and ultra-capacitor to control the DC-link voltage in wind generation units based on fully rated converter.

  7. Improved double integral sliding mode MPPT controller based parameter estimation for a stand-alone photovoltaic system

    International Nuclear Information System (INIS)

    Chatrenour, Nasrin; Razmi, Hadi; Doagou-Mojarrad, Hasan

    2017-01-01

    Highlights: • IDISMC based MPPT algorithm is introduced. • Hurwitz stability theorem is used for switching surface coefficients computation. • GA approach is presented for parameter estimation of the stand-alone PV system. - Abstract: In this paper, an Improved Double Integral Sliding Mode MPPT Controller (IDISMC) for a stand-alone photovoltaic (PV) system is proposed. Performance of a sliding mode controller (SMC) is greatly influenced by the choice of the sliding surface. Switching surface coefficients were selected by the use of Hurwitz stability theorem. The IDISMC not only is robust against parametric and non-parametric uncertainties, but also has a very small steady-state error, thanks to the use of double integral of tracking voltage error in the definition of its sliding surface. For realistic simulation, Genetic Algorithm (GA) method was used to estimate parameters of solar panels model. The validity of the proposed double integral SMC in maximum power point tracking was approved by comparing the simulation results obtained for a sample PV system with the results of other methods.

  8. Multi-objective optimal planning of the stand-alone microgrid system based on different benefit subjects

    International Nuclear Information System (INIS)

    Guo, Li; Wang, Nan; Lu, Hai; Li, Xialin; Wang, Chengshan

    2016-01-01

    As an important means to realize the energetic complementarity and improve the efficiency of renewable resources, the stand-alone microgrid (SAMG) system gains attention increasingly, especially in islands and remote areas. In this paper, considering the interest conflict of the distribution company and the distributed generation owner, a new multi-objective optimal planning model is formulated for medium voltage SAMG. Besides, to avoid the power constraint of distributed generation (DG) once the over-limit voltage occurs, a novel two-step power dispatch control method including the voltage regulation strategy is proposed, in which the absorption of distributed power by energy storage system (ESS) and the reactive power adjustment though its power control system are used to regulate voltage. The goal of this paper is to search the Pareto-optimal front of the site and capacity of DG as well as the contract price between both parties, and thus can provide effective references for practical planning of SAMG. Considering the high cost of ESS, the investment analysis of ESS is also discussed in the paper. - Highlights: • A multi-objective planning model based on different benefit subjects is proposed. • A two-step power dispatch method including the voltage regulation is proposed. • The economical efficiency of the proposed model is analyzed. • The effective reference for the stand-alone microgrid planning is provided.

  9. Stand-alone XLIF

    DEFF Research Database (Denmark)

    Hansen, E. J.; Simony, A.; Hummel, Stefan

    2015-01-01

    and clinical/radiological results in 22 patients treated with XLIF procedure for DS or degenerative disc disease (DDD). Material and methods: 22 consecutive patients with DS underwent surgery with the XLIF stand-alone procedure, with follow-up of 24 months. Clinical outcome scores were collected. Complications......Introduction: Adult thoracolumbar degeneration is an increasing challenge in the aging population. With age the progressive degeneration of the discs leads to an asymmetric collapse and a thoracolumbar coronal plane deformity, a degenerative scoliosis (DS). Aim: To evaluate the complication rate......-year follow-up, with a 31.8% revision rate. Due to the high revision rate we recommend supplementary posterior instrumentation, to achieve a higher fusion rate. When considering XLIF-stand-alone procedure for DS or DDD without supplemental posterior instrumentation, only single-level disease should...

  10. Stand-alone power systems for the future: Optimal design, operation and control of solar-hydrogen energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Ulleberg, Oeystein

    1999-12-31

    This thesis gives a systematic review of the fundamentals of energy systems, the governing physical and chemical laws related to energy, inherent characteristics of energy system, and the availability of the earth`s energy. It shows clearly why solar-hydrogen systems are one of the most viable options for the future. The main subject discussed is the modelling of SAPS (Stand-Alone Power Systems), with focus on photovoltaic-hydrogen energy systems. Simulation models for a transient simulation program are developed for PV-H{sub 2} components, including models for photovoltaics, water electrolysis, hydrogen storage, fuel cells, and secondary batteries. A PV-H{sub 2} demonstration plant in Juelich, Germany, is studied as a reference plant and the models validated against data from this plant. Most of the models developed were found to be sufficiently accurate to perform short-term system simulations, while all were more than accurate enough to perform long-term simulations. Finally, the verified simulation models are used to find the optimal operation and control strategies of an existing PV-H{sub 2} system. The main conclusion is that the simulation methods can be successfully used to find optimal operation and control strategies for a system with fixed design, and similar methods could be used to find alternative system designs. 148 refs., 78 figs., 31 tabs.

  11. Stand-alone power systems for the future: Optimal design, operation and control of solar-hydrogen energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Ulleberg, Oeystein

    1998-12-31

    This thesis gives a systematic review of the fundamentals of energy systems, the governing physical and chemical laws related to energy, inherent characteristics of energy system, and the availability of the earth`s energy. It shows clearly why solar-hydrogen systems are one of the most viable options for the future. The main subject discussed is the modelling of SAPS (Stand-Alone Power Systems), with focus on photovoltaic-hydrogen energy systems. Simulation models for a transient simulation program are developed for PV-H{sub 2} components, including models for photovoltaics, water electrolysis, hydrogen storage, fuel cells, and secondary batteries. A PV-H{sub 2} demonstration plant in Juelich, Germany, is studied as a reference plant and the models validated against data from this plant. Most of the models developed were found to be sufficiently accurate to perform short-term system simulations, while all were more than accurate enough to perform long-term simulations. Finally, the verified simulation models are used to find the optimal operation and control strategies of an existing PV-H{sub 2} system. The main conclusion is that the simulation methods can be successfully used to find optimal operation and control strategies for a system with fixed design, and similar methods could be used to find alternative system designs. 148 refs., 78 figs., 31 tabs.

  12. A stand alone computer system to aid the development of mirror fusion test facility RF heating systems

    International Nuclear Information System (INIS)

    Thomas, R.A.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF-B) control system architecture requires the Supervisory Control and Diagnostic System (SCDS) to communicate with a LSI-11 Local Control Computer (LCC) that in turn communicates via a fiber optic link to CAMAC based control hardware located near the machine. In many cases, the control hardware is very complex and requires a sizable development effort prior to being integrated into the overall MFTF-B system. One such effort was the development of the Electron Cyclotron Resonance Heating (ECRH) system. It became clear that a stand alone computer system was needed to simulate the functions of SCDS. This paper describes the hardware and software necessary to implement the SCDS Simulation Computer (SSC). It consists of a Digital Equipment Corporation (DEC) LSI-11 computer and a Winchester/Floppy disk operating under the DEC RT-11 operating system. All application software for MFTF-B is programmed in PASCAL, which allowed us to adapt procedures originally written for SCDS to the SSC. This nearly identical software interface means that software written during the equipment development will be useful to the SCDS programmers in the integration phase

  13. Integration of hydrogen energy technologies in stand-alone power systems analysis of the current potential for applications

    International Nuclear Information System (INIS)

    Zoulias, E.I.; Lymberopoulos, N.; Tsoutsos, T.; Glockner, R.; Mydske, H.J.; Vosseler, I.; Gavalda, O.; Taylor, P.

    2006-01-01

    The European study entitled: 'Market Potential Analysis for Introduction of Hydrogen Energy Technology in Stand-Alone Power Systems (H-SAPS)' aimed to establish a broad understanding of the market potential for H-SAPS and provide a basis for promoting in wide scale new technological applications. The scope of the study was limited to small and medium installations, up to a few hundred kW power rating and based on RE as the primary energy source. The potential for hydrogen technology in SAPS was investigated through an assessment of the technical potential for hydrogen, the market analysis and the evaluation of external factors. The results are mostly directed towards action by governments and the research community but also industry involvement is identified. The results include targeted market research, establishment of individual cost targets, regulatory changes to facilitate alternative grid solutions, information and capacity building, focused technology research and bridging the technology gaps. (author)

  14. A high-performance stand-alone solar PV power system for LED lighting

    KAUST Repository

    Huang, B. J.; Hsu, P. C.; Wu, M. S.; Chen, K.Y.

    2010-01-01

    The present study developed a high-performance solar PV power technology for the LED lighting of a solar home system. The nMPPO (near-Maximum-Power- Point- Operation) design is employed in system design to eliminate MPPT. A feedback control system

  15. Control aspects of the Schuchuli Village stand-alone photovoltaic power system

    Science.gov (United States)

    Groumpos, P. P.; Culler, J. E.; Delombard, R.

    1984-11-01

    A photovoltaic power system in an Arizona Indian village was installed. The control subsystem of this photovoltaic power system was analyzed. The four major functions of the control subsystem are: (1) voltage regulation; (2) load management; (3) water pump control; and (4) system protection. The control subsystem functions flowcharts for the control subsystem operation, and a computer program that models the control subsystem are presented.

  16. Sizing and economic analysis of stand alone photovoltaic system with hydrogen storage

    Science.gov (United States)

    Nordin, N. D.; Rahman, H. A.

    2017-11-01

    This paper proposes a design steps in sizing of standalone photovoltaic system with hydrogen storage using intuitive method. The main advantage of this method is it uses a direct mathematical approach to find system’s size based on daily load consumption and average irradiation data. The keys of system design are to satisfy a pre-determined load requirement and maintain hydrogen storage’s state of charge during low solar irradiation period. To test the effectiveness of the proposed method, a case study is conducted using Kuala Lumpur’s generated meteorological data and rural area’s typical daily load profile of 2.215 kWh. In addition, an economic analysis is performed to appraise the proposed system feasibility. The finding shows that the levelized cost of energy for proposed system is RM 1.98 kWh. However, based on sizing results obtained using a published method with AGM battery as back-up supply, the system cost is lower and more economically viable. The feasibility of PV system with hydrogen storage can be improved if the efficiency of hydrogen storage technologies significantly increases in the future. Hence, a sensitivity analysis is performed to verify the effect of electrolyzer and fuel cell efficiencies towards levelized cost of energy. Efficiencies of electrolyzer and fuel cell available in current market are validated using laboratory’s experimental data. This finding is needed to envisage the applicability of photovoltaic system with hydrogen storage as a future power supply source in Malaysia.

  17. Transforming stand-alone expert system into a community of cooperating agents

    CERN Document Server

    Jennings, N R; Aarnts, R P; Fuchs, J; Skarek, Paul

    1993-01-01

    Distributed Artificial Intelligence (DAI) systems in which multiple problem solving agents cooperate to achieve a common objective is a rapidly emerging and promising technology. However, as yet, there have been relatively few reported cases of such systems being employed to tackle real-world problems in realistic domains. One of the reasons for this is that DAI researchers have given virtually no consideration to the process of incorporating pre-existing systems into a community of cooperating agents. Yet reuse is a primary consideration for any organisation with a large software base. To redress the balance, this paper reports on an experiment undertaken at the CERN laboratories, in which two pre-existing and standalone expert systems for diagnosing faults in a particle accelerator were transformed into a community of cooperating agents. The experiences and insights gained during this process provide a valuable first step towards satisfying the needs of potential users of DAI technology - identifying the ty...

  18. A high-performance stand-alone solar PV power system for LED lighting

    KAUST Repository

    Huang, B. J.

    2010-06-01

    The present study developed a high-performance solar PV power technology for the LED lighting of a solar home system. The nMPPO (near-Maximum-Power- Point- Operation) design is employed in system design to eliminate MPPT. A feedback control system using pulse width modulation (PWM) technique was developed for battery charging control which can increase the charging capacity by 78%. For high-efficiency lighting, the LED is directly driven by battery using a PWM discharge control to eliminate a DC/DC converter. Two solar-powered LED lighting systems (50W and 100W LED) were built. The long-term outdoor tests have shown that the loss of load probability for full-night lighting requirement is zero for 50W LED and 3.6% for 100W LED. © 2010 IEEE.

  19. Stand alone power system coupling a PV field and a fuel cell: first experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Busquet, S.; Labbe, J.; Leroux, P.; Metkemeijer, R.; Mayer, D. [ENSMP-CENERG, Sophia Antipolis (France)

    2003-07-01

    The purpose of the work, through the PVFC-SYS project, is to optimise the operation of a system coupling a photovoltaic field, an electrolyser, a gas storage, a fuel cell and a power management unit. A test bench is at present finalised in the Laboratory. All components have been selected for an optimal, automatic, safe and reliable operation of the complete system. Fully instrumented, this test bench furnishes new data concerning each component and the complete system behaviour for variable real weather conditions and different load demands. The paper describes the test bench, the simulation tool based on empirical model fitted to the component experimental data and the complete system performance for different load profiles along a year of operation. (orig.)

  20. System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

    KAUST Repository

    Huang, B.J.

    2010-05-01

    The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m2. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). © 2010 Elsevier Ltd. All rights reserved.

  1. Maximun power point tracker of photovoltaic s panels for stand alone systems

    International Nuclear Information System (INIS)

    Stoll, R; Manno, R

    2005-01-01

    The low energetic efficiency of photovoltaic s panels is known, in addition, due to the use of linear regulators, which dissipate an important bit of the generated energy, the efficiency of the photovoltaic systems is still smaller.Also, the I-V characteristic curve of the photovoltaic modules depends on the solar radiation and the own temperature; consequently, the maximum power point (Wp) changes permanently.In conclusion, to produce electricity with photovoltaic panels is very expensive. However due to preserve the environment this technology is widely used.With the purpose of optimizing the amount of energy produced by the photovoltaic system, two complementary methods are used.One is the Maximum Power Point Tracker (MPPT) system and the other one is the Solar Tracker system.The objective of this project is to reduce that cost increasing the amount of energy produced by the solar panels using a Maximum Power Point Tracker system.This device consists of a DC/DC buck converter of high performance, controlled by a PIC 16F873 micro controller; which carries out the conversions of the analogical signals of the solar array to digital signals (ADC), the PIC output digital signals to the PWM control of the power FET (DAC), and calculates the Duty Cycle (D) for the point of I-V curve where this product becomes maximum.Measurements for different loads and battery charges were made.With the obtained results, the comparisons with a conventional system were made, a greater cession of energy to the load is observed.The main conclusion of this work is: Using a MPPT device to making work the PV module during the greater possible time near the maximum power point, the efficiency of the photovoltaic systems can be increased

  2. SAMAC program: the computer support for a stand-alone monitoring and control system

    International Nuclear Information System (INIS)

    Logg, C.A.

    1979-12-01

    The high energy physics experiments at SLAC require constant monitoring and control of the numerous components contained in the particle detection apparatus. This paper describes a basic hardware configuration and operating system which have been designed and implemented to satisfy the monitoring and control requirements of the many different setups used in these high energy physics experiments. It is based on the LSI-11 microprocessor with up to one million words of RAM and EPROM which are interchangeably mappable into the normal LSI-11 RAM/EPROM address space of 28K words. The entire system is modular in hardware and software so that it can easily be tailored to an individual experiment. The human interface is such that little training is required for effective use of the system

  3. PV LED ENGINE characterization lab for stand alone light-to-light systems

    DEFF Research Database (Denmark)

    Poulsen, Peter Behrensdorff; Thorsteinsson, Sune; Lindén, Johannes

    2015-01-01

    dimming functions for reliable lighting. A barrier for exploiting use of standalone solar lighting for the urban environment seem to be lack of knowledge and lack of available tools for proper dimensioning. In this work the development of powerful dimensioning tool is described and initial measurements...... are presented. Furthermore, a laboratory has been build to characterize these systems up to 200 Wp from “nose to tail” in great details to support improvement of the systems and to make accurate field performance predictions by the dimensioning tool....

  4. Optimal Sizing and Operation of Stand-Alone Hybrid Power Systems

    DEFF Research Database (Denmark)

    Kyriakidis, Ioannis; Chaudhary, Sanjay; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    for autonomous applications. Based on the island’s wind and solar potential, wind and solar systems appear as the most competitive solution while battery technologies provide the most feasible option for storing the excess energy. In the next, simulation models are developed in HOMER software. Various ratings...... of Renewable Energy Sources and Energy Storage Systems are considered and the most feasible combinations with respect to the Net Present Cost are calculated. The results have been assessed according to three scenarios, each of them representing a different policy and encountering several constraints....... Afterwards, steady-state analysis of the network is carried out considering typical cases of seasonal demand. The static model is developed in DIgSILENT PowerFactory software and the system’s behavior is investigated. In the following, the optimal placement for the wind, solar and storage units is discussed...

  5. Battery Storage Technologies for Electrical Applications: Impact in Stand-Alone Photovoltaic Systems

    OpenAIRE

    Daniel Akinyele; Juri Belikov; Yoash Levron

    2017-01-01

    Batteries are promising storage technologies for stationary applications because of their maturity, and the ease with which they are designed and installed compared to other technologies. However, they pose threats to the environment and human health. Several studies have discussed the various battery technologies and applications, but evaluating the environmental impact of batteries in electrical systems remains a gap that requires concerted research efforts. This study first presents an ove...

  6. New Scheme for Seamless Operation for Stand-Alone Power Systems

    Directory of Open Access Journals (Sweden)

    Hyun-Jun Kim

    2016-06-01

    Full Text Available On remote islands photovoltaic (PV panels with battery energy storage systems (BESSs supply electric power to customers in parallel operation with engine generators (EGs to reduce fuel consumption and environmental burden. A BESS operates in voltage control mode when it supplies power to loads alone, while it operates in current control mode when it supplies power to loads in parallel with the EG. This paper proposes a smooth mode change of the BESS from current control to voltage control by using initial value at the output of integral part in the voltage controller, and a smooth mode change from voltage control to current control by tracking the EG output voltage to the BESS output voltage using a phase-locked loop (PLL. The feasibility of the proposed scheme was verified through computer simulations and experiments with a scaled prototype.

  7. A Voltage and Frequency Control Strategy for Stand-Alone Full Converter Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Andrés Peña Asensio

    2018-02-01

    Full Text Available This paper addresses the design and analysis of a voltage and frequency control (VFC strategy for full converter (FC-based wind energy conversion systems (WECSs and its applicability for the supply of an isolated load. When supplying an isolated load, the role of the back-to-back converters in the FC must change with respect to a grid-connected application. Voltage and frequency are established by the FC line side converter (LSC, while the generator side converter (GSC is responsible for maintaining constant voltage in the DC link. Thus, the roles of the converters in the WECS are inverted. Under such control strategies, the LSC will automatically supply the load power and hence, in order to maintain a stable operation of the WECS, the wind turbine (WT power must also be controlled in a load-following strategy. The proposed VFC is fully modelled and a stability analysis is performed. Then, the operation of the WECS under the proposed VFC is simulated and tested on a real-time test bench, demonstrating the performance of the VFC for the isolated operation of the WECS.

  8. Investigation of heating and cooling in a stand-alone high temperature PEM fuel cell system

    International Nuclear Information System (INIS)

    Zhang, Caizhi; Yu, Tao; Yi, Jun; Liu, Zhitao; Raj, Kamal Abdul Rasheedj; Xia, Lingchao; Tu, Zhengkai; Chan, Siew Hwa

    2016-01-01

    Highlights: • Heating-up and cooling-down processes of HT-PEMFC are the mainly interested topics. • Dynamic behaviours, power and energy demand of the heating and cooling was studied. • Hybrid system based on LiFeYPO_4 battery for heating and cooling is built and tested. • The concept of combining different heating sources together is recommended. - Abstract: One key issue pertaining to the cold-start of High temperature PEM fuel cell (HT-PEMFC) is the requirement of high amount of thermal energy for heating up the stack to a temperature of 120 °C or above before it can generate electricity. Furthermore, cooling down the stack to a certain temperature (e.g. 50 °C) is necessary before stopping. In this study, the dynamic behaviours, power and energy demand of a 6 kW liquid cooled HT-PEMFC stack during heating-up, operation and cooling-down were investigated experimentally. The dynamic behaviours of fuel cell under heating-up and cooling-down processes are the mainly interested topics. Then a hybridisation of HT-PEMFC with Li-ion battery to demonstrate the synergistic effect on dynamic behaviour was conducted and validated for its feasibility. At last, the concept of combining different heating sources together is analysed to reduce the heating time of the HT-PEMFC as well.

  9. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  10. Power fluctuations suppression of stand-alone hybrid generation combining solar photovoltaic/wind turbine and fuel cell systems

    International Nuclear Information System (INIS)

    Ahmed, Nabil A.; Miyatake, Masafumi; Al-Othman, A.K.

    2008-01-01

    In this paper a hybrid energy system combining variable speed wind turbine, solar photovoltaic and fuel cell generation systems is presented to supply continuous power to residential power applications as stand-alone loads. The wind and photovoltaic systems are used as main energy sources while the fuel cell is used as secondary or back-up energy source. Three individual dc-dc boost converters are used to control the power flow to the load. A simple and cost effective control with dc-dc converters is used for maximum power point tracking and hence maximum power extracting from the wind turbine and the solar photovoltaic systems. The hybrid system is sized to power a typical 2 kW/150 V dc load as telecommunication power plants or ac residential power applications in isolated islands continuously throughout the year. The results show that even when the sun and wind are not available; the system is reliable and available and it can supply high-quality power to the load. The simulation results which proved the accuracy of the proposed controllers are given to demonstrate the availability of the proposed system in this paper. Also, a complete description of the management and control system is presented

  11. Modeling and Experimental Test of Grid-Tied Photovoltaic Cell Emulating System in the Stand-alone Mode

    Directory of Open Access Journals (Sweden)

    Vu Minh Phap

    2017-06-01

    Full Text Available In recent decades, generation of electricity from solar arrays has been increased to meet the world's growing energy demand. However, the utilization rate of the power conditioner in the grid-tied solar power system is low because the operation of solar panels is dependent on sunlight. Thus, we studied the method that the small scale wind power generating system in size from a few hundred watts to two or three kilowatts can be connected to the grid-tied power conditioner of the solar power system for residential applications with low power ratings (single phase, size is limited to 10kW by emulating characteristic of the solar panel. In this paper, we introduce the application of the grid-tied PV cell emulating system in the stand-alone mode to improve the utilization rate of the power conditioner. The simulation and experimental test results verify that the PV cell emulating system can operate the power conditioner of the gridtied solar power system.

  12. A Novel Method for Fast Configuration of Energy Storage Capacity in Stand-Alone and Grid-Connected Wind Energy Systems

    Directory of Open Access Journals (Sweden)

    Haixiang Zang

    2016-12-01

    Full Text Available In this paper, a novel method is proposed and applied to quickly calculate the capacity of energy storage for stand-alone and grid-connected wind energy systems, according to the discrete Fourier transform theory. Based on practical wind resource data and power data, which are derived from the American Wind Energy Technology Center and HOMER software separately, the energy storage capacity of a stand-alone wind energy system is investigated and calculated. Moreover, by applying the practical wind power data from a wind farm in Fujian Province, the energy storage capacity for a grid-connected wind system is discussed in this paper. This method can also be applied to determine the storage capacity of a stand-alone solar energy system with practical photovoltaic power data.

  13. Adaptive Artificial intelligence based fuzzy logic MPPTcontrol for stande-alone photovoltaic system under different atmospheric conditions

    Directory of Open Access Journals (Sweden)

    Zaghba Layachi

    2015-08-01

    Full Text Available there is an increased need for analysing the effect of atmospheric variables on photovoltaic (PV production and performance. The outputs from the different PV cells in different atmospheric conditions, such as irradiation and temperature , differ from each other evidencing knowledge deficiency in PV systems [14]. Maximum power point tracking (MPPT methods are used to maximize the PV array output power by tracking continuously the maximum power point (MPP. Among all MPPT methods existing in the literature, perturb and observe (P&O is the most commonly used for its simplicity and ease of implementation; however, it presents drawbacks such as slow response speed, oscillation around the MPP in steady state, and even tracking in wrong way under rapidly changing atmospheric conditions. In order to allow a functioning around the optimal point Mopt, we have inserted a DC-DC converter (Buck–Boost for a better matching between the PV and the load. This paper, we study the Maximum power point tracking using adaptive Intelligent fuzzy logic and conventional (P&O control for stande-alone photovoltaic Array system .In particular, the performances of the controllers are analyzed under variation weather conditions with are constant temperature and variable irradiation. The proposed system is simulated by using MATLAB-SIMULINK. According to the results, fuzzy logic controller has shown better performance during the optimization.

  14. Comparison of Turkey’s Geographical Regions in terms of Stand-Alone PV System Design and Cost Parameters

    Directory of Open Access Journals (Sweden)

    Nevzat Onat

    2017-01-01

    Full Text Available Stand-alone photovoltaic (SAPV systems are widely used in rural areas where there is no national grid or as a precaution against power outages. In this study, technical and economic analysis of a SAPV system was carried out using meteorological data for 75 province centers in seven geographical regions of Turkey. Obtained results for each province center were separated by geographical area. The averages of the centers for each region are taken as output. A calculation algorithm based on MsExcel has been established for these operations. The analyses made with the developed algorithm are repeated for five different scenarios that they cover periods of time when a constant strong load is active for all seasons (winter, spring, summer, and autumn and all year round. The developed algorithm calculates the life-cycle cost, the unit energy cost, the electrical capacity utilization rate, the amount of generated/excess energy per month, the initial investment/replacement, and operating and maintenance (O&M costs of each element. As a result, geographical regions of Turkey are compared in terms of these outputs graphically. Further investigations may include the sale of excess energy generated, small-scale PV system cost factors parallel to the grid, and the effects of government incentives.

  15. Modeling and control design of a stand alone wind energy conversion system based on functional model predictive control

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, Ahmed M. [Beni-Suef University, Electrical Dept., Beni Suef (Egypt)

    2012-09-15

    This paper investigates the application of the model predictive control (MPC) approach to control the voltage and frequency of a stand alone wind generation system. This scheme consists of a wind turbine which drives an induction generator feeding an isolated load. A static VAR compensator is connected at the induction generator terminals to regulate the load voltage. The rotor speed, and thereby the load frequency are controlled via adjusting the mechanical power input using the blade pitch-angle. The MPC is used to calculate the optimal control actions including system constraints. To alleviate computational effort and to reduce numerical problems, particularly in large prediction horizon, an exponentially weighted functional model predictive control (FMPC) is employed. Digital simulations have been carried out in order to validate the effectiveness of the proposed scheme. The proposed controller has been tested through step changes in the wind speed and the load impedance. Simulation results show that adequate performance of the proposed wind energy scheme has been achieved. Moreover, this scheme is robust against the parameters variation and eliminates the influence of modeling and measurement errors. (orig.)

  16. Multi-Objective Optimal Design of Stand-Alone Hybrid Energy System Using Entropy Weight Method Based on HOMER

    Directory of Open Access Journals (Sweden)

    Jiaxin Lu

    2017-10-01

    Full Text Available Implementation of hybrid energy system (HES is generally considered as a promising way to satisfy the electrification requirements for remote areas. In the present study, a novel decision making methodology is proposed to identify the best compromise configuration of HES from a set of feasible combinations obtained from HOMER. For this purpose, a multi-objective function, which comprises four crucial and representative indices, is formulated by applying the weighted sum method. The entropy weight method is employed as a quantitative methodology for weighting factors calculation to enhance the objectivity of decision-making. Moreover, the optimal design of a stand-alone PV/wind/battery/diesel HES in Yongxing Island, China, is conducted as a case study to validate the effectiveness of the proposed method. Both the simulation and optimization results indicate that, the optimization method is able to identify the best trade-off configuration among system reliability, economy, practicability and environmental sustainability. Several useful conclusions are given by analyzing the operation of the best configuration.

  17. Techno-economic analysis of stand-alone photovoltaic/wind/battery/hydrogen systems for very small-scale applications

    Directory of Open Access Journals (Sweden)

    Stojković Saša M.

    2016-01-01

    Full Text Available The paper presents the results of a technical and economic analysis of three stand-alone hybrid power systems based on renewable energy sources which supply a specific group of low-power consumers. This particular case includes measuring sensors and obstacle lights on a meteorological mast for wind measurements requiring an uninterrupted power supply in cold climate conditions. Although these low-power (100 W measuring sensors and obstacle lights use little energy, their energy consumption is not the same as the available solar energy obtained on a daily or seasonal basis. In the paper, complementarity of renewable energy sources was analysed, as well as one of short-term lead-acid battery-based storage and seasonal, hydrogen-based (electrolyser, H2 tank, and fuel cells storage. These relatively complex power systems were proposed earlier for high-power consumers only, while this study specifically highlights the role of the hydrogen system for supplying low-power consumers. The analysis employed a numerical simulation method using the HOMER software tool. The results of the analysis suggest that solar and wind-solar systems, which involve meteorological conditions as referred to in this paper, include a relatively large number of lead-acid batteries. Additionally, the analysis suggests that the use of hydrogen power systems for supplying low power-consumers is entirely justifiable, as it significantly reduces the number of batteries (two at minimum in this particular case. It was shown that the increase in costs induced by the hydrogen system is acceptable.

  18. An adaptive artificial neural network model for sizing stand-alone photovoltaic systems: Application for isolated sites in Algeria

    International Nuclear Information System (INIS)

    Mellit, A.; Benghanem, M.; Hadj Arab, A.; Guessoum, G.

    2004-07-01

    In this paper we investigate, by using an adaptive Artificial Neural Network (ANN), in order to find a suitable model for sizing Stand-Alone Photovoltaic (SAPV) systems, based on a minimum of input data. This model combines Radial Basis Function (RBF) network and Infinite Impulse Response (IIR) filter in order to accelerate the convergence of the network. For the sizing of a photovoltaic (PV) system, we need to determine the optimal sizing coefficients (K PV , K B . These coefficients allow us to determine the number of solar panels and storage batteries necessary to satisfy a given consumption, especially in isolated sites where the global solar radiation data is not always available and which are considered the most important parameters for sizing a PV system. Obtained results by classical models (analytical, numerical, analytical- numerical, B-spline function) and new models like feed-forward (MLP), radial basis function (RBF), MLP-IIR and RBF-IIR have been compared with experimental sizing coefficients in order to illustrate the accuracy of the results of the new developed model. This model has been trained by using 200 known optimal sizing coefficients corresponding to 200 locations in Algeria. In this way, the adaptive model was trained to accept and even handle a number of unusual cases, the unknown validation sizing coefficients set produced very set accurate estimation and a correlation coefficient of 98% was obtained between the calculated and that estimated by the RBF-IIR model. This result indicates that the proposed method can be successfully used for the estimation of optimal sizing coefficients of SAPV systems for any locations in Algeria, but the methodology can be generalized using different locations over the world. (author)

  19. Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging.

    Science.gov (United States)

    Park, Jinhyoung; Hu, Changhong; Shung, K Kirk

    2011-12-01

    A stand-alone front-end system for high-frequency coded excitation imaging was implemented to achieve a wider dynamic range. The system included an arbitrary waveform amplifier, an arbitrary waveform generator, an analog receiver, a motor position interpreter, a motor controller and power supplies. The digitized arbitrary waveforms at a sampling rate of 150 MHz could be programmed and converted to an analog signal. The pulse was subsequently amplified to excite an ultrasound transducer, and the maximum output voltage level achieved was 120 V(pp). The bandwidth of the arbitrary waveform amplifier was from 1 to 70 MHz. The noise figure of the preamplifier was less than 7.7 dB and the bandwidth was 95 MHz. Phantoms and biological tissues were imaged at a frame rate as high as 68 frames per second (fps) to evaluate the performance of the system. During the measurement, 40-MHz lithium niobate (LiNbO(3)) single-element lightweight (<;0.28 g) transducers were utilized. The wire target measure- ment showed that the -6-dB axial resolution of a chirp-coded excitation was 50 μm and lateral resolution was 120 μm. The echo signal-to-noise ratios were found to be 54 and 65 dB for the short burst and coded excitation, respectively. The contrast resolution in a sphere phantom study was estimated to be 24 dB for the chirp-coded excitation and 15 dB for the short burst modes. In an in vivo study, zebrafish and mouse hearts were imaged. Boundaries of the zebrafish heart in the image could be differentiated because of the low-noise operation of the implemented system. In mouse heart images, valves and chambers could be readily visualized with the coded excitation.

  20. Stand-alone photovoltaic applications. Lessons learned

    International Nuclear Information System (INIS)

    Loois, G.; Van Hemert, B.

    1999-02-01

    The IEA Photovoltaic Power Systems Programme (PVPS) is one of the collaborative R and D agreements established within the IEA. The objective of Task III is to promote and facilitate the exchange of information and experiences in the field of PV Systems in Stand-alone and Island Applications (SAPV). The book focuses on the practical experiences gained, and does not aim to provide a complete manual on SAPV. When Task III started its activities in 1993, a collection of 50 'State of the art' projects was published in the book 'Examples of Stand-Alone Photovoltaic Systems'. This publication marked the base line for the work of the task. Now, in 1998, the showcases from each country demonstrate the lessons learned in five years of cooperation. The book consists of two parts. The first part contains eight chapters dealing with a specific aspect of stand-alone PV. The second part introduces 14 national showcase projects in a systematic presentation. Each chapter and showcase can be read independently from the rest of the book. Chapter 2, contributed by The Netherlands, analyses the market for stand-alone PV systems. It gives an overview of the 'traditional' application of stand-alone PV, which is the electrification of remote buildings and which has been addressed in depth in other publications. The focus is on the market niches of service applications that are also interesting for more densely populated areas, e.g. in industrialised countries. The United Kingdom illustrates the economic aspects in Chapter 3. Cost comparisons are made, but more important is the illustration of the non-financial considerations that make PV the preferred choice as a power source for many applications. Switzerland explores in Chapter 4 (financing aspects) different financing mechanisms, and financial policies used to overcome the initial cost barrier. Most of these approaches have been applied in developing countries rather than in the western world. Using various examples from all over the

  1. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A.; Campos, J. [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A. [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1997-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  2. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A; Campos, J [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1998-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  3. A compact seven switches topology and reduced DC-link capacitor size for single-phase stand-alone PV system with hybrid energy storages

    DEFF Research Database (Denmark)

    Liu, Xiong; Wang, Peng; Loh, Poh Chiang

    2011-01-01

    Single-phase stand-alone PV system is suitable for household applications in remote area. Hybrid battery/ultra-capacitor energy storage can reduce charge and discharge cycles and avoid deep discharges of battery. This paper proposes a compact seven switches structure for stand-alone PV system......, which otherwise needs nine switches configuration, inclusive of one switch for boost converter, four switches for single-phase inverter and four switches for two DC/DC converters of battery and ultra-capacitor. It is well-known that a bulky DC-link capacitor is always required to absorb second......-order harmonic current caused by single-phase inverter. In the proposed compact topology, a small size DC-link capacitor can achieve the same function through charging/discharging control of ultra-capacitor to mitigate second-order ripple current. Simulation results are provided to validate the effectiveness...

  4. Stand-alone microgrids

    NARCIS (Netherlands)

    Bauer, P.; Weldemariam, L.E.; Raijen, E.

    2011-01-01

    Abstract- A hybrid power system (HPS) which consists of diesel Genset, PV -arrays and wind turbines with energy storing and power electronic devices is discussed in this paper. An inventory of different connection topologies is made for some of the sources that generate AC power and others that

  5. The Stand-alone Heliostat

    International Nuclear Information System (INIS)

    Garcia Navajas, G. I.; Egea Gea, A.

    2000-01-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-nr, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modem working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modem. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced.by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs

  6. Planning tool for least cost system design based on the operating experience of fifty stand-alone photovoltaic hybrid systems

    Energy Technology Data Exchange (ETDEWEB)

    Bopp, G.; Neufeld, R.; Preiser, K.; Puls, H.-G.; Sauer, D.U.; Senft, S.; Schulz, M. [Fraunhofer Inst. for Solar Energy Systems ISE, Freiburg (Germany)

    2001-07-01

    The Fraunhofer Institute for Solar Energy (ISE) conducted a project involving the design and installation of grid-independent photovoltaic systems with battery storage to 30 remote lodges, mountain huts, farms and private houses. More than half the participating dwellings belonged to the German Alpine Club and are used only for summer months. The photovoltaic systems ranged from lighting for unattended huts and larger systems for lodges with permanent staff and an electricity demand in the order of 0.1 to 40 kWh per day. The objective of the project was to determine the amount of maintenance work that is required to keep the systems working reliably. The Institute prepared inspection manuals and carried out some sample inspections. Other inspections were carried out by the independent operator. With the information entered into the inspection manuals, Fraunhofer ISE analyzed the causes of faults and prepared statistics on interruptions to operations. The average probability of breakdowns could then be determined along with the requirements for optimizing individual components and the entire system. Besides the solar generator, most components of a photovoltaic system with battery storage require repairs, post-installation improvements, regular maintenance or replacement of batteries at intervals of 5 to 10 years. At the end of two years of regular maintenance, the fault rates were reduced from 3 to 1. The Institute also developed the Technical and Least Cost Optimisation (TALCO) tool to calculate the lifetime costs of remote area power supply systems. TALCO describes the electrical characteristics of various components under operating conditions. All economic factors linked to the components are considered. The optimisation algorithm presents the minimum lifetime costs for a given energy demand at specific locations under given boundary conditions. Analytical results showed that PV-hybrid systems are the most cost effective solution for most system applications

  7. Factors that can influence the economic feasibility of stand-alone and grid-connected photovoltaic systems: case studies using the software AVES-F

    International Nuclear Information System (INIS)

    Blasques, L.C.M.; Pinho, J.T.

    2004-01-01

    This paper presents case studies of economic feasibility of solar photovoltaic systems using the software AVES-F (Analysis of Economic Feasibility of Photovoltaic Systems), developed by the authors, considering cases of stand-alone and grid-connected systems. The software takes into account several factors that can influence the economic feasibility of these kind of systems, like load to be supplied, distance to the grid, the use regime of the system, applied subsidies and others. The main goal of this paper is to analyze some of these factors and to observe how they can affect the economics of PV systems for electricity generation. (authors)

  8. System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

    KAUST Repository

    Huang, B.J.; Hsu, P.C.; Wu, M.S.; Ho, P.Y.

    2010-01-01

    . This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first

  9. Low-Cost SCADA System Using Arduino and Reliance SCADA for a Stand-Alone Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Ibrahim Allafi

    2018-01-01

    Full Text Available SCADA (supervisory control and data acquisition systems are currently employed in many applications, such as home automation, greenhouse automation, and hybrid power systems. Commercial SCADA systems are costly to set up and maintain; therefore those are not used for small renewable energy systems. This paper demonstrates applying Reliance SCADA and Arduino Uno on a small photovoltaic (PV power system to monitor the PV current, voltage, and battery, as well as efficiency. The designed system uses low-cost sensors, an Arduino Uno microcontroller, and free Reliance SCADA software. The Arduino Uno microcontroller collects data from sensors and communicates with a computer through a USB cable. Uno has been programmed to transmit data to Reliance SCADA on PC. In addition, Modbus library has been uploaded on Arduino to allow communication between the Arduino and our SCADA system by using MODBUS RTU protocol. The results of the experiments demonstrate that SCADA works in real time and can be effectively used in monitoring a solar energy system.

  10. Effect of State Feedback Coupling and System Delays on the Transient Performance of Stand-Alone VSI with LC Output Filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    The influence of state feedback coupling in the dynamics performance of power converters for stand-alone microgrids is investigated. Computation and PWM delays are the main factors that limit the achievable bandwidth of current regulators in digital implementations. In particular, the performance...... of state feedback decoupling is degraded because of these delays. Two decoupling techniques to improve the transient response of the system are investigated, named non-ideal and ideal capacitor voltage decoupling respectively. In particular, the latter solution consists in leading the capacitor voltage...... on the state feedback decoupling path in order to compensate for system delays. Practical implementation issues are discussed with reference to both the decoupling techniques. A design methodology for the voltage loop, that considers the closed loop transfer functions developed for the inner loop, is also...

  11. Synchronized Pulsed dc - dc Converter as Maximum Power Position Tracker with Wide Load and Insolation Variation for Stand Alone PV System

    International Nuclear Information System (INIS)

    Hardik, P. Desai; Ranjan Maheshwari

    2011-01-01

    This paper investigates the interest focused on employing parallel connected dc-dc converter with high tracking effectiveness under wide variation in environmental conditions (Insolation) and wide load variation. dc-dc converter is an essential part of the stand alone PV system. Paper also presents an approach on how duty cycle for maximum power position (MPP) is adjusted by taking care of varying load conditions and without iterative steps. Synchronized PWM pulses are employed for the converter. High tracking efficiency is achieved with continuous input and inductor current. In this approach, the converter can he utilized in buck as well in boost mode. The PV system simulation was verified and experimental results were in agreement to the presented scheme. (authors)

  12. A Study on Electric Power Smoothing System for Lead-Acid Battery of Stand-Alone Natural Energy Power System Using EDLC

    Science.gov (United States)

    Jia, Yan; Shibata, Ryosuke; Yamamura, Naoki; Ishida, Muneaki

    To resolve energy shortage and global warming problem, renewable natural resource and its power system has been gradually generalizing. However, the power fluctuation suppressing in short period and the balance control of consumption and supply in long period are two of main problems that need to be resolved urgently in natural energy power system. In Stand-alone Natural Energy Power System (SNEPS) with power energy storage devices, power fluctuation in short period is one of the main reasons that recharge cycle times increase and lead-acid battery early failure. Hence, to prolong the service life of lead-acid battery and improve power quality through suppressing the power fluctuation, we proposed a method of electric power smoothing for lead-acid battery of SNEPS using bi-directional Buck/Boost converter and Electric Double Layer Capacitor (EDLC) in this paper. According to the test data of existing SNEPS, a power fluctuation condition is selected and as an example to analyze the validity of the proposed method. The analysis of frequency characteristics indicates the power fluctuation is suppressed a desired range in the target frequency region. The experimental results of confirmed the feasibility of the proposed system and the results well satisfy the requirement of system design.

  13. A comparison study of performance for three stand-alone PV systems used in rural electrification in Libya

    International Nuclear Information System (INIS)

    Ibrahim, I. M. Saleh; Kreama, N. M.; Khalat, M. A.

    2006-01-01

    Rural photovoltaic electrification in Libya is a national program to electrify isolated villages, as part of this program 250 systems with a total peak power of about 300 K Wp has been put into work starting the beginning of the year 2003, the sizes of the systems are 1.8 K Wp, 1.2 K Wp, 0.75 K Wp, and 0.15 K Wp, the systems was designed to supply different family needs. All systems are equipped by a data logger to collect the system parameters. In this paper we will compare the performance of three different PV sizes through two year of work. The results showed that the systems are performing incomparable to the deigned parameters, very little power failure was reported, and there are technical and social issues has to be addressed before the installation of the PV system.(Author)

  14. A feasibility study of a stand-alone hybrid solar–wind–battery system for a remote island

    International Nuclear Information System (INIS)

    Ma, Tao; Yang, Hongxing; Lu, Lin

    2014-01-01

    Highlights: • A feasibility study of a hybrid solar–wind–battery system is carried out. • Techno-economic evaluation is conducted for this proposed system. • Thousands of cases are simulated to achieve an optimal system configuration. • The performance of the proposed system is analyzed in detail. • A sensitivity analysis on its load and renewable energy resource is performed. - Abstract: This paper presents a detailed feasibility study and techno-economic evaluation of a standalone hybrid solar–wind system with battery energy storage for a remote island. The solar radiation and wind data on this island in 2009 was recorded for this study. The HOMER software was employed to do the simulations and perform the techno-economic evaluation. Thousands of cases have been carried out to achieve an optimal autonomous system configuration, in terms of system net present cost (NPC) and cost of energy (COE). A detailed analysis, description and expected performance of the proposed system were presented. Moreover, the effects of the PV panel sizing, wind turbine sizing and battery bank capacity on the system’s reliability and economic performance were examined. Finally, a sensitivity analysis on its load consumption and renewable energy resource was performed to evaluate the robustness of economic analysis and identify which variable has the greatest impact on the results. The results demonstrate the techno-economic feasibility of implementing the solar–wind–battery system to supply power to this island

  15. A GUI Based Software for Sizing Stand Alone AC Coupled Hybrid PV-Diesel Power System under Malaysia Climate

    Science.gov (United States)

    Syafiqah Syahirah Mohamed, Nor; Amalina Banu Mohamat Adek, Noor; Hamid, Nurul Farhana Abd

    2018-03-01

    This paper presents the development of Graphical User Interface (GUI) software for sizing main component in AC coupled photovoltaic (PV) hybrid power system based on Malaysia climate. This software provides guideline for PV system integrator to design effectively the size of components and system configuration to match the system and load requirement with geographical condition. The concept of the proposed software is balancing the annual average renewable energy generation and load demand. In this study, the PV to diesel generator (DG) ratio is introduced by considering the hybrid system energy contribution. The GUI software is able to size the main components in the PV hybrid system to meet with the set target of energy contribution ratio. The rated powers of the components to be defined are PV array, grid-tie inverter, bi-directional inverter, battery storage and DG. GUI is used to perform all the system sizing procedures to make it user friendly interface as a sizing tool for AC coupled PV hybrid system. The GUI will be done by using Visual Studio 2015 based on the real data under Malaysia Climate.

  16. Efficient estimator of probabilities of large power spills in an stand-alone system with wind generation and storage

    NARCIS (Netherlands)

    D. Bhaumik (Debarati); D.T. Crommelin (Daan); A.P. Zwart (Bert)

    2016-01-01

    textabstractThe challenges of integrating unpredictable wind energy into a power system can be alleviated using energy storage devices. We assessed a single domestic energy system with a wind turbine and a battery. We investigated the best operation mode of the battery such that the occurrence of

  17. A new technique based on Artificial Bee Colony Algorithm for optimal sizing of stand-alone photovoltaic system

    OpenAIRE

    Mohamed, Ahmed F.; Elarini, Mahdi M.; Othman, Ahmed M.

    2013-01-01

    One of the most recent optimization techniques applied to the optimal design of photovoltaic system to supply an isolated load demand is the Artificial Bee Colony Algorithm (ABC). The proposed methodology is applied to optimize the cost of the PV system including photovoltaic, a battery bank, a battery charger controller, and inverter. Two objective functions are proposed: the first one is the PV module output power which is to be maximized and the second one is the life cycle cost (LCC) whic...

  18. Decentralized/stand-alone hybrid Wind-Diesel power systems to meet residential loads of hot coastal regions

    International Nuclear Information System (INIS)

    Elhadidy, M.A.; Shaahid, S.M.

    2005-01-01

    In view of rising costs, pollution and fears of exhaustion of oil and coal, governments around the world are encouraging to seek energy from renewable/sustainable energy sources such as wind. The utilization of energy from wind (since the oil embargo of the 1970s) is being widely disseminated for displacement of fossil fuel produced energy and to reduce atmospheric degradation. A system that consists of a wind turbine and Diesel genset is called a Wind-Diesel power system.The literature indicates that the commercial/residential buildings in Saudi Arabia consume an estimated 10-40% of the total electric energy generated. In the present study, the hourly mean wind-speed data of the period 1986-1997 recorded at the solar radiation and meteorological station, Dhahran (26 deg. 32'N, 50 deg. 13'E in the Eastern Coastal Region of Saudi Arabia), has been analyzed to investigate the potential of utilizing hybrid (Wind-Diesel) energy conversion systems to meet the load requirements of a hundred typical two bedroom residential buildings (with annual electrical energy demand of 3512 MWh). The long term monthly average wind speeds for Dhahran range from 4.2 to 6.4 m/s. The hybrid systems considered in the present case study consist of different combinations/clusters of 150 kW commercial wind machines supplemented with battery storage and Diesel back-up. The deficit energy generated by the Diesel generator (for different battery capacities) and the number of operational hours of the Diesel system to meet a specific annual electrical energy demand of 3512 MWh have also been presented. The evaluation of the hybrid system shows that with seven 150 kW wind energy conversion system (WECS) and one day of battery storage, the Diesel back-up system has to provide 21.6% of the load demand. Furthermore, with three days of battery storage, the Diesel back-up system has to provide 17.5% of the load demand. However, in the absence of battery storage, about 37% of the load needs to be

  19. Modeling and simulation of stand-alone hybrid power system with fuzzy MPPT for remote load application

    Directory of Open Access Journals (Sweden)

    Bogaraj T.

    2015-09-01

    Full Text Available Many parts of remote locations in the world are not electrified even in this Advanced Technology Era. To provide electricity in such remote places renewable hybrid energy systems are very much suitable. In this paper PV/Wind/Battery Hybrid Power System (HPS is considered to provide an economical and sustainable power to a remote load. HPS can supply the maximum power to the load at a particular operating point which is generally called as Maximum Power Point (MPP. Fuzzy Logic based MPPT (FLMPPT control method has been implemented for both Solar and Wind Power Systems. FLMPPT control technique is implemented to generate the optimal reference voltage for the first stage of DC-DC Boost converter in both the PV and Wind energy system. The HPS is tested with variable solar irradiation, temperature, and wind speed. The FLMPPT method is compared with P&O MPPT method. The proposed method provides a good maximum power operation of the hybrid system at all operating conditions. In order to combine both sources, the DC bus voltage is made constant by employing PI Controllers for the second stage of DC-DC Buck-Boost converter in both Solar and Wind Power Systems. Battery Bank is used to store excess power from Renewable Energy Sources (RES and to provide continuous power to load when the RES power is less than load power. A SPWM inverter is designed to convert DC power into AC to supply three phase load. An LC filter is also used at the output of inverter to get sinusoidal current from the PWM inverter. The entire system was modeled and simulated in Matlab/Simulink Environment. The results presented show the validation of the HPS design.

  20. A new technique based on Artificial Bee Colony Algorithm for optimal sizing of stand-alone photovoltaic system.

    Science.gov (United States)

    Mohamed, Ahmed F; Elarini, Mahdi M; Othman, Ahmed M

    2014-05-01

    One of the most recent optimization techniques applied to the optimal design of photovoltaic system to supply an isolated load demand is the Artificial Bee Colony Algorithm (ABC). The proposed methodology is applied to optimize the cost of the PV system including photovoltaic, a battery bank, a battery charger controller, and inverter. Two objective functions are proposed: the first one is the PV module output power which is to be maximized and the second one is the life cycle cost (LCC) which is to be minimized. The analysis is performed based on measured solar radiation and ambient temperature measured at Helwan city, Egypt. A comparison between ABC algorithm and Genetic Algorithm (GA) optimal results is done. Another location is selected which is Zagazig city to check the validity of ABC algorithm in any location. The ABC is more optimal than GA. The results encouraged the use of the PV systems to electrify the rural sites of Egypt.

  1. A new technique based on Artificial Bee Colony Algorithm for optimal sizing of stand-alone photovoltaic system

    Directory of Open Access Journals (Sweden)

    Ahmed F. Mohamed

    2014-05-01

    Full Text Available One of the most recent optimization techniques applied to the optimal design of photovoltaic system to supply an isolated load demand is the Artificial Bee Colony Algorithm (ABC. The proposed methodology is applied to optimize the cost of the PV system including photovoltaic, a battery bank, a battery charger controller, and inverter. Two objective functions are proposed: the first one is the PV module output power which is to be maximized and the second one is the life cycle cost (LCC which is to be minimized. The analysis is performed based on measured solar radiation and ambient temperature measured at Helwan city, Egypt. A comparison between ABC algorithm and Genetic Algorithm (GA optimal results is done. Another location is selected which is Zagazig city to check the validity of ABC algorithm in any location. The ABC is more optimal than GA. The results encouraged the use of the PV systems to electrify the rural sites of Egypt.

  2. Fuel cells, batteries and super-capacitors stand-alone power systems management using optimal/flatness based-control

    Energy Technology Data Exchange (ETDEWEB)

    Benaouadj, M.; Aboubou, A.; Bahri, M.; Boucetta, A. [MSE Laboratory, Mohamed khiderBiskra University (Algeria); Ayad, M. Y., E-mail: ayadmy@gmail.com [R& D, Industrial Hybrid Vehicle Applications (France)

    2016-07-25

    In this work, an optimal control (under constraints) based on the Pontryagin’s maximum principle is used to optimally manage energy flows in a basic PEM (Proton Exchange Membrane) fuel cells system associated to lithium-ion batteries and supercapacitors through a common DC bus having a voltage to stabilize using the differential flatness approach. The adaptation of voltage levels between different sources and load is ensured by use of three DC-DC converters, one boost connected to the PEM fuel cells, while the two others are buck/boost and connected to the lithiumion batteries and supercapacitors. The aim of this paper is to develop an energy management strategy that is able to satisfy the following objectives: Impose the power requested by a habitat (representing the load) according to a proposed daily consumption profile, Keep fuel cells working at optimal power delivery conditions, Maintain constant voltage across the common DC bus, Stabilize the batteries voltage and stored quantity of charge at desired values given by the optimal control. Results obtained under MATLAB/Simulink environment prove that the cited objectives are satisfied, validating then, effectiveness and complementarity between the optimal and flatness concepts proposed for energy management. Note that this study is currently in experimentally validation within MSE Laboratory.

  3. Optimal/flatness based-control of stand-alone power systems using fuel cells, batteries and supercapacitors

    Directory of Open Access Journals (Sweden)

    Mahdi Benaouadj

    2017-03-01

    Full Text Available In this work, an optimal control (under constraints based on the Pontryagin’s maximum principle is used to optimally manage energy flows in a basic PEM (Proton Exchange Membrane fuel cells system associated to lithium-ion batteries and supercapacitors through a common DC bus having a voltage to stabilize using the differential flatness approach. The adaptation of voltage levels between different sources and load is ensured by use of three DCDC converters, one boost connected to the PEM fuel cells, while the two others are buck/boost and connected to the lithium-ion batteries and supercapacitors. The aim of this paper is to develop an energy management strategy that is able to satisfy the following objectives: - Impose the power requested by a habitat (representing the load according to a proposed daily consumption profile, - Keep fuel cells working at optimal power delivery conditions, - Maintain constant voltage across the common DC bus, - Stabilize the batteries voltage and stored quantity of charge at desired values given by the optimal control. Results obtained under MATLAB/Simulink environment prove that the cited objectives are satisfied, validating then, effectiveness and complementarity between the optimal and flatness concepts proposed for energy management. Note that this study is currently in experimentally validation within MSE Laboratory.

  4. A practical multi-objective design approach for optimum exhaust heat recovery from hybrid stand-alone PV-diesel power systems

    International Nuclear Information System (INIS)

    Yousefi, Moslem; Kim, Joong Hoon; Hooshyar, Danial; Yousefi, Milad; Sahari, Khairul Salleh Mohamed; Ahmad, Rodina Binti

    2017-01-01

    Highlights: • Heat recovery exchanger is designed based on practical conditions of a hybrid power system. • Off-the-grid electricity system modeling and analysis using micro-grid analysis software HOMER. • NSGA-II is used for the multi-objective design optimization task. • A new local search is proposed to incorporate the engineering knowledge in NSGA-II. • The proposed approach outperforms the existing ones. - Abstract: Integration of solar power and diesel generators (DGs) together with battery storage has proven to be an efficient choice for stand-alone power systems (SAPS). For higher energy efficiency, heat recovery from exhaust gas of the DG can also be employed to supply all or a portion of the thermal energy demand. Although the design of such heat recovery systems (HRSs) has been studied, the effect of solar power integration has not been taken into account. In this paper, a new approach for practical design of these systems based on varying engine loads is presented. Fast and elitist non-dominated sorting genetic algorithm (NSGA-II) equipped with a novel local search was used for the design process, considering conflicting objectives of annual energy recovery and total cost of the system, and six design variables. An integrated power system, designed for a remote SAPS, was used to evaluate the design approach. The optimum power supply system was first designed using the commercial software Hybrid Optimization of Multiple Energy Resources (HOMER), based on power demand and global solar energy in the region. Heat recovery design was based on the outcome of HOMER for DG hourly load, considering different power scenarios. The proposed approach improves the annual heat recovery of the PV/DG/battery system by 4%, PV/battery by 1.7%, and stand-alone DG by 1.8% when compared with a conventional design based on nominal DG load. The results prove that the proposed approach is effective and that load calculations should be taken into account prior to

  5. Hydrogen-based energy storage unit for stand alone PV systems; L'hydrogene electrolytique comme moyen de stockage d'electricite pour systemes photovoltaiques isoles

    Energy Technology Data Exchange (ETDEWEB)

    Labbe, J

    2006-12-15

    Stand alone systems supplied only by a photovoltaic generator need an energy storage unit to be fully self sufficient. Lead acid batteries are commonly used to store energy because of their low cost, despite several operational constraints. A hydrogen-based energy storage unit (HESU) could be another candidate, including an electrolyser, a fuel cell and a hydrogen tank. However many efforts still need to be carried out for this technology to reach an industrial stage. In particular, market outlets must be clearly identified. The study of small stationary applications (few kW) is performed by numerical simulations. A simulator is developed in the Matlab/Simulink environment. It is mainly composed of a photovoltaic field and a storage unit (lead acid batteries, HESU, or hybrid storage HESU/batteries). The system component sizing is achieved in order to ensure the complete system autonomy over a whole year of operation. The simulator is tested with 160 load profiles (1 kW as a yearly mean value) and three locations (Algeria, France and Norway). Two coefficients are set in order to quantify the correlation between the power consumption of the end user and the renewable resource availability at both daily and yearly scales. Among the tested cases, a limit value of the yearly correlation coefficient came out, enabling to recommend the use of the most adapted storage to a considered case. There are cases for which using HESU instead of lead acid batteries can increase the system efficiency, decrease the size of the photovoltaic field and improve the exploitation of the renewable resource. In addition, hybridization of HESU with batteries always leads to system enhancements regarding its sizing and performance, with an efficiency increase by 10 to 40 % depending on the considered location. The good agreement between the simulation data and field data gathered on real systems enabled the validation of the models used in this study. (author)

  6. Optimal Sizing of a Stand-Alone Hybrid Power System Based on Battery/Hydrogen with an Improved Ant Colony Optimization

    Directory of Open Access Journals (Sweden)

    Weiqiang Dong

    2016-09-01

    Full Text Available A distributed power system with renewable energy sources is very popular in recent years due to the rapid depletion of conventional sources of energy. Reasonable sizing for such power systems could improve the power supply reliability and reduce the annual system cost. The goal of this work is to optimize the size of a stand-alone hybrid photovoltaic (PV/wind turbine (WT/battery (B/hydrogen system (a hybrid system based on battery and hydrogen (HS-BH for reliable and economic supply. Two objectives that take the minimum annual system cost and maximum system reliability described as the loss of power supply probability (LPSP have been addressed for sizing HS-BH from a more comprehensive perspective, considering the basic demand of load, the profit from hydrogen, which is produced by HS-BH, and an effective energy storage strategy. An improved ant colony optimization (ACO algorithm has been presented to solve the sizing problem of HS-BH. Finally, a simulation experiment has been done to demonstrate the developed results, in which some comparisons have been done to emphasize the advantage of HS-BH with the aid of data from an island of Zhejiang, China.

  7. Methodology for predicting sequences of mean monthly clearness index and daily solar radiation data in remote areas: Application for sizing a stand-alone PV system

    Energy Technology Data Exchange (ETDEWEB)

    Mellit, A. [Department of Electronics, Institute of Sciences Engineering, Centre University of Medea, Medea 26000 (Algeria); Department of Electronics, Faculty of Science Engineering, Blida University, Blida 09000 (Algeria); Kalogirou, S.A. [Higher Technical Institute, P.O. Box 20423, Nicosia 2152 (Cyprus); Shaari, S. [Faculty of Applied Sciences, Universiti Teknologi MARA 40450 Shah Alam, Selangor (Malaysia); Salhi, H. [Department of Electronics, Faculty of Science Engineering, Blida University, Blida 09000 (Algeria); Hadj Arab, A. [Development Centre of Renewable Energy (CDER), P.O. Box 62, Bouzareah, Algiers 16000 (Algeria); Departamento de Energias Renerables, CIEMAT, Arda Complutense, 22, Madrid 28040 (Spain)

    2008-07-15

    In this paper, a suitable adaptive neuro-fuzzy inference system (ANFIS) model is presented for estimating sequences of mean monthly clearness index (anti K{sub t}) and total solar radiation data in isolated sites based on geographical coordinates. The magnitude of solar radiation is the most important parameter for sizing photovoltaic (PV) systems. The ANFIS model is trained by using a multi-layer perceptron (MLP) based on fuzzy logic (FL) rules. The inputs of the ANFIS are the latitude, longitude, and altitude, while the outputs are the 12-values of mean monthly clearness index anti K{sub t}. These data have been collected from 60 locations in Algeria. The results show that the performance of the proposed approach in the prediction of mean monthly clearness index anti K{sub t} is favorably compared to the measured values. The root mean square error (RMSE) between measured and estimated values varies between 0.0215 and 0.0235 and the mean absolute percentage error (MAPE) is less than 2.2%. In addition, a comparison between the results obtained by the ANFIS model and artificial neural network (ANN) models, is presented in order to show the advantage of the proposed method. An example for sizing a stand-alone PV system is also presented. This technique has been applied to Algerian locations, but it can be generalized for any geographical position. It can also be used for estimating other meteorological parameters such as temperature, humidity and wind speed. (author)

  8. 11kW stand alone wind turbine based on proven wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Wodstrup, J.; Andersen, J.

    2004-01-01

    and enable control of frequency and voltage independently on both the grid side and the generator side. The prototype has been installed at Risø. The paper will present results from test runs of the system both operating stand-alone supplying a single load and in parallel operation with a diesel genset....

  9. The Impact of Course Delivery Systems on Student Achievement and Sense of Community: A Comparison of Learning Community versus Stand-Alone Classroom Settings in an Open-Enrollment Inner City Public Community College

    Science.gov (United States)

    Bandyopadhyay, Pamela

    2010-01-01

    This study examined the effects of two types of course delivery systems (learning community classroom environments versus stand-alone classroom environments) on the achievement of students who were simultaneously enrolled in remedial and college-level social science courses at an inner city open-enrollment public community college. This study was…

  10. Basic Stand Alone Medicare Inpatient Claims PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Inpatient Public Use Files (PUF) named CMS 2008 BSA Inpatient Claims PUF with information from 2008 Medicare...

  11. Basic Stand Alone Carrier Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Carrier Line Items Public Use Files (PUF) with information from Medicare Carrier claims. The CMS BSA Carrier Line...

  12. Developing a mobile stand alone photovoltaic generator

    International Nuclear Information System (INIS)

    Soler-Bientz, R.; Ricalde-Cab, L.O.; Solis-Rodriguez, L.E.

    2006-01-01

    This paper describes a recent work developed to create a mobile stand alone photovoltaic generator that can be easily relocated in remote areas to evaluate the feasibility of photovoltaic energy applications. A set of sensors were installed to monitor the electric current and voltage of the energy generated, the energy stored and the energy used by the loads that may be connected to the system. Other parameters like solar radiations (both on the horizontal and on the photovoltaic generation planes) and temperatures (of both the environment and the photovoltaic module) were monitored. This was done while considering the important role of temperature in the photovoltaic module performance. Finally, a measurement and communication hardware was installed to interface the system developed with a conventional computer. In this way, the performance of the overall system in real rural conditions could be evaluated efficiently. Visual software that reads, visualizes and saves the data generated by the system was also developed by means of the LabVIEW programming environment

  13. Research and development of utilization system of photovoltaic power generation. R and D of stand-alone system (desalination system for remote island-reverse osmosis)

    Energy Technology Data Exchange (ETDEWEB)

    1986-08-01

    This system is an independent system which utilizes DC power obtained by a solar cell for the power source for a sea water desalination plant. The system is constructed of 2 series of a reverse osmosis membrane module system by which the power storage requirement in the battery is minimized by storing in the form of water instead. Effective battery capacity is 46.2 KWH which corresponds to the operation of 0.7 days. Hoso-jima in the central part of the Seto Inland Sea is estimated as the plant location and satisfies the conditions of this verification test. It is being examined to use the solar cells of single and poly crystal types as they have been often practically used to a considerable extent, because the test plant is going to be used as a commercial plant after the test operation is completed. Nominal capacity of 0.55 m/sup 2//h was set for the reverse osmosis sea water desalination unit on the basis of 4.5 m/sup 2//d (a daily average for the agricultural water required for 1,000 m/sup 2/ hydroponic area). Annual average water production is roughly 5.3 m/sup 2//d. (2 figs, 1 tab)

  14. IEA PVPS Task 3. Use of photovoltaic systems in stand-alone and island applications. 'Swiss participation'; IEA PVPS Task 3. Use of photovoltaic systems in stand-alone and island applications. 'Participation Suisse'

    Energy Technology Data Exchange (ETDEWEB)

    Villoz, M. [Dynatex SA, Morges (Switzerland)

    2004-07-01

    This report describes the work done during five years of the second phase of Task 3 of the photovoltaic power systems programme of the International Energy Agency (IEA-PVPS). Task 3 activities were concentrated on stand-alone photovoltaic systems with the main effort on improving the quality and reducing the cost of these systems. The work was divided in 2 sub-tasks whose first one was concentrated on quality insurance schemes and second one on technical recommendations coming from practical experience. Twelve original reports have been published covering topics that can be sorted in 4 categories: the first one is dedicated on quality issues with a review of existing standards in the participating countries and a double paper giving quality assurance recommendations on project management and examples of applying these rules in practical cases. The second category dwelled on photovoltaic systems with papers on charge controllers, on lightning protection and monitoring of systems. The third category presents interesting studies on the storage of energy which remains the main subject where improvements should be made in order to lower the cost of energy; four papers describe the management and the test procedures of lead-acid batteries, how to choose a lead-acid battery and finally are there alternatives to lead-acid batteries for the storage of photovoltaic electricity. The last category worked on loads and users of renewable energy and gives a large amount of experience with loads, how to choose them and how the energy can be better used through demand side management. (author)

  15. Research and development of utilization system of photovoltaic power generation. R and D of stand-alone power system (for marine use)

    Energy Technology Data Exchange (ETDEWEB)

    1986-08-01

    This is an annual report for 1985 for NEDO -contracted project. The project aims at establishing an efficient, stable power generating solar cell technology and developing a power supply system for the ocean development. In order to install an independent off-shore power supply system for the marine ranch at Kamiura, Oita Prefecture, a frame berge was constructed on the Tsuinoura pier and an annularly arranged disc type solar cell with the center tapered at 4 % in an umbrella shape towards outside. Designed capacity was 10 KWp maximum output, and total 11 KVA (1 KVA at heavy duty load and 10 KVA at sun-shining load). The power source system consists of units for solar cell, power storage, control, orthogonal conversion, and of various loads. The system can make a normal observation by a wireless data transmission from off-shore onto the ground. (2 figs, 4 tabs)

  16. Study on photovoltaic power systems. Development of dispersed stand-alone system (seawater desalination system for remote island areas-osmosis)

    Energy Technology Data Exchange (ETDEWEB)

    1987-09-01

    This study deals with development of a system of seawater osmosis desalination for remote island areas and agricultural-process water-supply. The demonstration system, installed in Hosojima, was simulated for examination. The yearly-averaged generated electric energy was 76 kWh/day, and the consumed energy 72 kWh/day. The calculated water productivity was 5.5 m/sup 3//day in the first step, and 4.9 m/sup 3//day in the second. This amount had a high balance with that required for hydropholic water of 4.5 m/sup 3//day. The generated output was 30.8 kWp (power range of 10-100 kW) for the solar cells, and 840 Ah for the electric batteries. The generated direct-current power was supplied to the loads without use of a DA converter, which contributes to the high energy efficiency and the inexpensiveness of the system. This system can be unattendantly operated in the normal conditions. After construction of the demonstration plant, the respective units and the total system were adjusted to give good results. (1 fig, 1 tab)

  17. Feasibility Analysis and Simulation of a Stand-Alone Photovoltaic Energy System for Electricity Generation and Environmental Sustainability – Equivalent to 650VA Fuel-Powered Generator – Popularly Known as “I Pass My Neighbour”

    International Nuclear Information System (INIS)

    Ani, Vincent Anayochukwu

    2015-01-01

    Photovoltaic (PV) power system can be used to replace wholly 650VA generator for electricity generation for household use in Nigeria. This paper presented the feasibility analysis of load data and simulation study of a stand-alone PV power system that produced the electrical needs of a household. This study is based on designing of PV energy system for household use. The patterns of load consumption within the household were studied and suitably modeled for simulation. The simulation study indicates that energy requirements to provide electricity, which is equivalent to 650VA generator for household use in Nigeria, can be accomplished by 520 W solar PV array, 2312 Ah nominal capacity battery, and a 1 kW DC/AC inverter. This would be suitable for deployment of 100% clean energy for environmental sustainability and uninterruptable power performance in the household. The results of this research show that, with a low-power consuming appliances, it is possible to meet the entire annual electricity demand of a single household solely through a stand-alone PV energy supply. Installing solar panels by most Nigerian home can significantly reduce home reliance on government power thereby reduce the strain on the current capacity of our power generation infrastructure. A detailed design and description of the system were presented in this paper.

  18. Feasibility Analysis and Simulation of a Stand-Alone Photovoltaic Energy System for Electricity Generation and Environmental Sustainability – Equivalent to 650VA Fuel-Powered Generator – Popularly Known as “I Pass My Neighbour”

    Energy Technology Data Exchange (ETDEWEB)

    Ani, Vincent Anayochukwu, E-mail: vincent_ani@yahoo.com [Department of Electronic Engineering, University of Nigeria Nsukka, Nsukka (Nigeria)

    2015-09-11

    Photovoltaic (PV) power system can be used to replace wholly 650VA generator for electricity generation for household use in Nigeria. This paper presented the feasibility analysis of load data and simulation study of a stand-alone PV power system that produced the electrical needs of a household. This study is based on designing of PV energy system for household use. The patterns of load consumption within the household were studied and suitably modeled for simulation. The simulation study indicates that energy requirements to provide electricity, which is equivalent to 650VA generator for household use in Nigeria, can be accomplished by 520 W solar PV array, 2312 Ah nominal capacity battery, and a 1 kW DC/AC inverter. This would be suitable for deployment of 100% clean energy for environmental sustainability and uninterruptable power performance in the household. The results of this research show that, with a low-power consuming appliances, it is possible to meet the entire annual electricity demand of a single household solely through a stand-alone PV energy supply. Installing solar panels by most Nigerian home can significantly reduce home reliance on government power thereby reduce the strain on the current capacity of our power generation infrastructure. A detailed design and description of the system were presented in this paper.

  19. Stand-alone photovoltaic system: study of a modular concept with distributed communication and control units; Systeme photovoltaique autonome: etude d'une structure modulaire a gestion repartie

    Energy Technology Data Exchange (ETDEWEB)

    Neusser, A

    2004-09-15

    This thesis concerns an innovative photovoltaic system concept, which is modular am where the standardisation of all of the components is possible. Lead-acid batteries tare used to store the energy. The main objective of this project is the improvement of the battery management process in the system. As the batteries are the weak point of the system, a new battery charger is developed aiming at a longer life-span and a homogeneous ageing rate for all of them. This charger permits energy exchanges, which are co-ordinated by a communication system. We use a DC/DC converter as power electronics for battery charging. PSpice simulations and tests verify its performance. Simulations with Matlab Simulink show the auto-equalization tendency of the chosen battery management method. In addition, an experimentation under real conditions validates the beneficial effect on the state of health of the batteries. (author)

  20. Techno-Economic Evaluation of a Stand-Alone Power System Based on Solar Power/Batteries for Global System for Mobile Communications Base Stations

    Directory of Open Access Journals (Sweden)

    Mohammed H. Alsharif

    2017-03-01

    Full Text Available Energy consumption in cellular networks is receiving significant attention from academia and the industry due to its significant potential economic and ecological influence. Energy efficiency and renewable energy are the main pillars of sustainability and environmental compatibility. Technological advancements and cost reduction for photovoltaics are making cellular base stations (BSs; a key source of energy consumption in cellular networks powered by solar energy sources a long-term promising solution for the mobile cellular network industry. This paper addresses issues of deployment and operation of two solar-powered global system for mobile communications (GSM BSs that are being deployed at present (GSM BS 2/2/2 and GSM BS 4/4/4. The study is based on the characteristics of South Korean solar radiation exposure. The optimum criteria as well as economic and technical feasibility for various BSs are analyzed using a hybrid optimization model for electric renewables. In addition, initial capital, replacement, operations, maintenance, and total net present costs for various solar-powered BSs are discussed. Furthermore, the economic feasibility of the proposed solar system is compared with conventional energy sources in urban and remote areas.

  1. Benchmarking the Collocation Stand-Alone Library and Toolkit (CSALT)

    Science.gov (United States)

    Hughes, Steven; Knittel, Jeremy; Shoan, Wendy; Kim, Youngkwang; Conway, Claire; Conway, Darrel J.

    2017-01-01

    This paper describes the processes and results of Verification and Validation (VV) efforts for the Collocation Stand Alone Library and Toolkit (CSALT). We describe the test program and environments, the tools used for independent test data, and comparison results. The VV effort employs classical problems with known analytic solutions, solutions from other available software tools, and comparisons to benchmarking data available in the public literature. Presenting all test results are beyond the scope of a single paper. Here we present high-level test results for a broad range of problems, and detailed comparisons for selected problems.

  2. Techno-economy optimization of PV-diesel hybrid / stand-alone systems for remote area power supply based on empirical analysis for Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Budiono, Chayun [Komplek BPP Teknologi, Jl. Teknologi VII, Jakarta (Indonesia)

    2007-07-01

    The techno-economy assessment of photovoltaic (PV) system applications for remote area power supply (RAPS) in combination with operation of diesel generating set (DGS) in Indonesia based on an empirical model is formulated. This model has shown that it helps the project owner to easily optimise the sub-system size (i.e. PV array, auxiliary generator and battery sizes) based on the financial constraints needed for the investment and operation of the system. Two major markets of RAPS in Indonesia are currently for rural electrification and telecommunication systems (orig.)

  3. Performance evaluation of a stand-alone solar dish Stirling system for power generation suitable for off-grid rural electrification

    International Nuclear Information System (INIS)

    Kadri, Y.; Hadj Abdallah, H.

    2016-01-01

    Highlights: • Estimation of the output temperature reached by 2 m parabolic dish. • Output power estimation for uncontrollable load was done using Matlab®. • Validation of the proposed system under Tunisian conditions for rural electrification. - Abstract: The development of green power generation such as solar systems that have become a great interest for several countries especially for Tunisia as it presents a significant solar potential. For this purpose, this research has investigated the feasibility and the performance of standalone solar dish/Stirling micro generation plant for rural electrification. The considered hybrid system includes solar dish/Stirling engine, permanent magnet synchronous generator and a storage battery. To start with, thermal modeling and simulation have been carried out using Matlab® for the solar-driven Stirling heat engine system composed of an Alpha Stirling engine, a solar collector and a receiver, in which the radiation, convection, conduction and radiation heat loss have been taken into consideration for the selected design. For numerical validation of the receiver’s thermal model, simulation results were compared with experimental measurements reported for the EURODISH system with a reasonable degree of agreement. Second, the generated torque driving the generator has been estimated by the Adiabatic model of URIELI based on the classical fourth-order Runge-Kutta. In order for an autonomous control, the dish generator is connected to the load via power electronic converters where the bidirectional power flow is possible by the use of two voltage source converters in a back-to-back configuration. They are referred to as Stirling/generator side converter and load side inverter, both are oriented control by space vector pulse width modulation. In this context, the Stirling side converter is used to adjust the synchronous generator while the inverter controls the power flow between the direct current bus and the

  4. A new method for estimating insolation based on PV-module currents in a cluster of stand-alone solar systems

    NARCIS (Netherlands)

    Nieuwenhout, F; van der Borg, N; van Sark, W.G.J.H.M.; Turkenburg, W.C.

    2007-01-01

    In order to evaluate the performance of solar home systems (SHSs), data on local insolation is a prerequisite. We present a new method to estimate insolation if direct measurements are unavailable. This method comprises estimation of daily irradiation by correlating photovoltaic (PV) module currents

  5. Estimating insolation based on PV-module currents in a cluster of stand-alone solar systems: Introduction of a new method

    NARCIS (Netherlands)

    Nieuwenhout, F; van den Borg, N.; van Sark, W.G.J.H.M.; Turkenburg, W.C.

    In order to evaluate the performance of solar home systems (SHS), data on local insolation is a prerequisite. We present the outline of a new method to estimate insolation if direct measurements are unavailable. This method comprises estimation of daily irradiation by correlating photovoltaic

  6. Loss Distribution Analysis of a Three-Port Converter for Low-Power Stand-Alone Light-to-Light Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2016-01-01

    In locations far from the equator achieving high conversion efficiency in low-power solar systems is challenging due to low solar irradiance levels. This paper presents a high efficiency three-port converter (TPC) for light-to-light (LtL) applications where no direct solar conversion is required...... demonstrates high efficiency in both power flow paths. At low irradiation level, the power flow from the photovoltaic panel to the battery shows a peak efficiency of 99.1% at at 1.5 W output power, and the LED driver stage presents a peak efficiency of 97.3% at 3 W output power....

  7. Optimization of PV/Wind/Battery stand-alone system, using hybrid FPA/SA algorithm and CFD simulation, case study: Tehran

    International Nuclear Information System (INIS)

    Tahani, Mojtaba; Babayan, Narek; Pouyaei, Arman

    2015-01-01

    Highlights: • The utilization of an optimized Hybrid PV/Wind/Battery system has been studied. • The proposed system has been studied for a building in Tehran. • A novel hybrid optimization method, namely FPA/SA has been proposed. • The impact of inclined part of the roof on wind velocity is studied by CFD. • LPSP and Payback time were considered as objective functions in this study. - Abstract: Renewable energy hybrid systems are a promising technology toward sustainable and clean development. Due to stochastic behavior of renewable energy sources, optimization of their convertors has great importance for increasing system’s reliability and efficiency and also in order to decrease the costs. In this research study, it was aimed to study the utilization of an optimized hybrid PV/Wind/Battery system for a three story building, with an inclined surface on the edge of its roof, located in Tehran, capital of Iran. For this purpose, a new evolutionary based optimization technique, namely hybrid FPA/SA algorithm was developed, in order to maximize system’s reliability and minimize system’s costs. The new algorithm combines the approaches which are utilized in Flower Pollination Algorithm (FPA) and Simulated Annealing (SA) algorithm. The developed algorithm was validated using popular benchmark functions. Moreover the influence of PV panels tilt angle (which is equal to the slope of inclined part of the roof) is studied on the wind speed by using computational fluid dynamics (CFD) simulation. The outputs of CFD simulations are utilized as inputs for modeling wind turbine performance. The Loss of Power Supply Probability (LPSP) and Payback time are considered as objective functions, and PV panel tilt angle, number of PV panels and number of batteries are selected as decision variables. The results showed that if the tilt angle for PV panels is set equal to 30° and the number of PV panels is selected equal to 11 the fastest payback time which is 12 years and

  8. Techno-economic analysis of stand alone solar pv systems for remote base stations in Ghana. (a case study at Abofrem vodafone cell site)

    International Nuclear Information System (INIS)

    Denkyira, Samuel

    2015-06-01

    Information and Communications Technologies (ICT) have become an important part of today’s global economy. ICT infrastructural development is developing at a very fast pace in Ghana. Growth is above the 1.1% average for Sub-Saharan Africa. The growth in the sector has meant a massive investment in telecommunication infrastructure such as base stations from telecom companies such as Vodafone, Millicom, Glo, Espresso, MTN etc. Hundreds of base stations have been installed all over the country. Currently base stations depend mainly on the national grid, with diesel generators as backups, for its power requirement. In some remote or hilly areas where there are no grid supplied electricity, base stations are usually powered with diesel fuelled generators since lengthy grid extensions may not be cost effective. In addition to high fuel delivery and consumption costs, maintenance of the generators can also be expensive in terms of parts and labour time working on the unit. There are also concerns about environmental pollution using diesel generators. Photovoltaic technology has the ability to convert solar energy into electricity consuming no fossil fuels, using no moving parts, creating no pollution and noise, and lasting for years with little maintenance. The environmental, noise, reliability and power availability benefits of the PV system make it an attractive option. Ghana, being a few degrees north of the equator, is endowed with enormous solar energy resource spread across the entire country. Daily solar radiation level ranges from 4 kWh/m 2 to 6 kWh/m 2 . The annual sunshine duration ranges between 1800 to 3000 hours offering very high potential for grid connected and off grid applications. In this thesis work, the use of solar PV technology as a cost effective source of power for cellular base stations in remote or hilly areas, far off the national grid, is reviewed. RETScreen software is used to determine the technical and financial viability of the PV system

  9. Multi-site evaluation of a computer aided detection (CAD) algorithm for small acute intra-cranial hemorrhage and development of a stand-alone CAD system ready for deployment in a clinical environment

    Science.gov (United States)

    Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.

    2010-03-01

    Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.

  10. Hydrogen Gas Production in a Stand-Alone Wind Farm

    Directory of Open Access Journals (Sweden)

    M. Naziry Kordkandy

    2017-04-01

    Full Text Available This paper is analyzing the operation of a stand-alone wind farm with variable speed turbines, permanent magnet synchronous generators (PMSG and a system for converting wind energy during wind speed variations. On this paper, the design and modeling of a wind system which uses PMSG’s to provide the required power of a hydrogen gas electrolyzer system, is discussed. This wind farm consists of three wind turbines, boost DC-DC converters, diode full bridge rectifiers, permanent magnet synchronous generators, MPPT control and a hydrogen gas electrolyzer system. The MPPT controller based on fuzzy logic is designed to adjust the duty ratio of the boost DC-DC converters to absorb maximum power. The proposed fuzzy logic controller assimilates, with (PSF MPPT algorithm which generally used to absorb maximum power from paralleled wind turbines and stores it in form of hydrogen gas. The system is modeled and its behavior is studied using the MATLAB software.

  11. 39 CFR 122.2 - Stand-alone special services.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Stand-alone special services. 122.2 Section 122.2 Postal Service UNITED STATES POSTAL SERVICE POST OFFICE SERVICES [DOMESTIC MAIL] SERVICE STANDARDS FOR MARKET-DOMINANT SPECIAL SERVICES PRODUCTS § 122.2 Stand-alone special services. (a) The service standard...

  12. Integral type small PWR with stand-alone safety

    International Nuclear Information System (INIS)

    Makihara, Yoshiaki

    2001-01-01

    A feasibility study is achieved on an integral type small PWR with stand-alone safety. It is designed to have the following features. (1) The coolant does not leak out at any accidental condition. (2) The fuel failure does never occur while it is supposed on the large scale PWR at the design base accident. (3) At any accidental condition the safety is secured without any support from the outside (stand-alone safety secure). (4) It has self-regulating characteristics and easy controllability. The above features can be satisfied by integrate the steam generator and CRDM in the reactor vessel while the pipe line break has to be considered on the conventional PWR. Several counter measures are planned to satisfy the above features. The economy feature is also attained by several simplifications such as (1) elimination of main coolant piping and pressurizer by the integration of primary cooling system and self-pressurizing, (2) elimination of RCP by application of natural circulating system, (3) elimination of ECCS and accumulator by application of static safety system, (4) large scale volume reduction of the container vessel by application of integrated primary cooling system, (5) elimination of boric acid treatment by deletion of chemical shim. The long operation period such as 10 years can be attained by the application of Gd fuel in one batch refueling. The construction period can be shortened by the standardizing the design and the introduction of modular component system. Furthermore the applicability of the reduced modulation core is also considered. (K. Tsuchihashi)

  13. Stand-alone induction generators for small water power schemes

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Adam [Intermediate Technology Development Group, Rugby (United Kingdom); Smith, Nigel [Smith Associates, Nottingham (United Kingdom)

    1996-04-01

    Conventional technology for isolated power generation is the synchronous generator. Using stand-alone induction generators has proved to have tremendous advantages in remote regions of developing countries, where electricity has significant social benefits. (author)

  14. Basic Stand Alone Medicare DME Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Durable Medical Equipment (DME) Line Items Public Use Files (PUF) with information from Medicare DME claims. The...

  15. Basic Stand Alone Skilled Nursing Facility Beneficiary PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Skilled Nursing Facility (SNF) Beneficiary Public Use Files (PUF) with information from Medicare SNF claims. The...

  16. STAND-ALONE WIND ENERGY CONVERSION SYSTEM WITH MAXIMUM POWER TRANSFER CONTROL SISTEMA AISLADO DE CONVERSIÓN EÓLICA CON CONTROL DE MÁXIMA TRANSFERENCIA DE POTENCIA

    Directory of Open Access Journals (Sweden)

    Miguel López

    2009-12-01

    Full Text Available A controlled wind generation system for a stand alone application is presented in this paper. A cascaded step-up/step-down power electronic converters topology is proposed to control the wind power system in the whole wind speed range. For the low wind speed range, the control strategy is aimed to follow the wind turbine’s maximal power coefficient by adjusting the generator’s rotational speed. For high wind speeds, the system power regulation is also made by controlling the generator speed. This control is made by the DC/DC power electronic converter, which modifies its input voltage, changing the machine voltage and consequently varying the generator’s rotor speed. The proposed system is validated by computer simulation. The proposed control system shows a good performance for its application in autonomous wind energy systems.Un sistema de generación eólica para una aplicación aislada es presentado en este artículo. Una topología de convertidores electrónicos de potencia elevador y reductor conectados en cascada es propuesta para controlar la producción eólica en todo el rango de velocidades del viento. Para el rango de vientos suaves, la estrategia de control permite seguir el máximo coeficiente de potencia de turbina eólica mediante el ajuste de la velocidad de rotación del generador. En el rango de vientos fuertes, la regulación de la potencia del sistema se hace igualmente por control de la velocidad de giro del generador. La acción de control es realizada mediante el convertidor DC/DC de potencia el cual modifica su tensión de entrada, cambiando así la tensión en los terminales de la máquina y por consecuencia variando la velocidad de rotación del generador. El sistema propuesto es validado mediante simulación por computador. Los resultados muestran que el sistema de control propuesto actúa de buena manera para su aplicación en sistemas autónomos de generación eólica.

  17. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  18. A control strategy for PV stand-alone applications

    International Nuclear Information System (INIS)

    Slouma, S; Baccar, H

    2015-01-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system

  19. Sensorless direct voltage control of the stand-alone brushless doubly-fed generator

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The conventional stand-alone brushless doubly-fed generator (BDFG) control strategies need the feedback from the rotor position or speed sensors, which can reduce system reliability and increase the cost and axial volume of the machine. In this paper, a sensorless direct voltage control (DVC) str......) strategy is presented for the stand-alone BDFG. The satisfactory dynamic performance is verified by experimental results under four kinds of typical operation conditions. Besides, the proposed control strategy is robust due to no generator parameters being required....

  20. Improving efficiency of a regional stand alone bone bank.

    Science.gov (United States)

    Warnock, Jonathan M; Rowan, Clare H; Davidson, Helen; Millar, Ciara; McAlinden, M Gavan

    2016-03-01

    The introduction of a stand-alone Bone Bank in our Regional Orthopaedic Hospital has improved the availability of femoral head allograft. Benninger et al. (Bone Joint J 96-B:1307-1311, 2014), demonstrated their institutions bank to be cost effective despite a 30 % discard rate for harvested allograft. We sought to audit our own discard rates and subsequent cost-effectiveness of our bone bank. Donor recruitment. Before approaching a potential donor, our establishment's nurse specialists review their clinical notes and biochemical laboratory results, available on a regional Electronic Care Records. They view femoral head architecture on radiographs against set criteria, Patient Archive and Communication system (SECTRA, Sweden). In total 1383 femoral heads were harvested, 247 were discarded giving an overall rate of 17.9 %. The most common reasons for discard of harvested graft was a positive microbiology/bacteriology result, n = 96 (38.9 %). After a rise in discard rates in 2007, we have steadily reduced our discard rates since 2006/2007 (28.2 %), 2008/2009 (17 %), 2010/2011 (14.8 %), and finally to 10.3 % in 2012/2013. In the current financial year, our cost to harvest, test, store and release a femoral head is £ 610. With a structured donor recruitment process and unique pre-operative radiographic analysis we have successfully reduced our discard rates bi-annually making our bone bank increasingly cost-effective.

  1. The Stand-alone Heliostat; El Heliostato Autonomo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Navajas, G.; Egea Gea, A. [Ciemat. Madrid (Spain)

    2000-07-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-m''2, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24 Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modern working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modern. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs.

  2. The Stand-alone Heliostat; El Heliostato Autonomo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Navajas, G; Egea Gea, A [Ciemat. Madrid (Spain)

    2000-07-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-m''2, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24 Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modern working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modern. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs.

  3. Environmental/Climatic Effect on Stand-Alone Solar Energy Supply ...

    African Journals Online (AJOL)

    This paper investigates the climatic eects and environmental variations on the performance of a stand-alone photovoltaic system. The eects of partial shading with dierent climate conditions and load resistance variations were examined. A survey of some of the work done in this eld of environmental eect on solar panel was ...

  4. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability...

  5. Stand-alone solutions, computer networks and extern communications

    International Nuclear Information System (INIS)

    Tarschisch, H.

    1988-01-01

    The advantages of local networks over stand-alone solutions are presented. Of the local networks (LAN), two are presently at the center of attention: the bus and the ring. ETHERNET and the IBM-Token-Ring are described as typical examples. Access to public networks, especially TELEPAC and ISDN, is discussed. 12 figs

  6. Fiscal 2000 regional new energy vision formulation - Financially aided project. Report on regional new energy vision formulation for Ueno village (Object of survey: Commercialization feasibility study for a stand-alone type wind power generation system at Ueno German Culture Village); 2000 nendo Uenoson chiiki shin energy vision sakutei hokokusho. Ueno Doitsu bunkamura dokuritsugata furyoku hatsuden system jigyoka feasibility study chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A survey is conducted about the profitability of installing a stand-alone type wind power system at Ueno village (Miyako Island), Okinawa Prefecture. The German Culture Village, which is an integrated resort house provided with accommodations (500 people), educational and cultural facilities, and sports facilities consumes 272 MWh/year in electric power. The results of the survey are summarized in six chapters, which are (1) the survey of the business under the project to be the object of feasibility study, (2) project to be the object of feasibility study, (3) outline of the Okinawa Electric Power Co., Inc., Miyakojima system and problems to ensue from its interconnection with wind turbines, (4) survey of stand-alone type wind turbine power generation systems, (5) technical/economic feasibility study, and (6) project management and future tasks. It is concluded that there will be profit in the presence of a subsidy that covers 65% or more of the total cost of constructing a system comprising three 600 KW wind turbines, three 400 kW class diesel generators, and storage batteries. (NEDO)

  7. Methodology for the design of a stand-alone photovoltaic power supply

    OpenAIRE

    López Seguel, Julio; Seleme Junior, Seleme Isaac; Donoso-Garcia, Pedro F; Ferreira Morais, Lenin Martins; Cabaleiro Cortizo, Porfirio; Severo Mendes, Marcos A

    2013-01-01

    This paper presents a complete methodology for the design of an autonomous photovoltaic system to maximize the use of solar energy. It is a method that prioritizes the best cost-effective choice at every step of the project. In order to ensure the proper use and extended battery life time, a control strategy for charging the batteries is proposed. Experimental results are provided for a stand-alone photovoltaic system with low electrical power, intended primarily for the illumination and basi...

  8. Analysis and controller design for stand-alone VSIs in synchronous reference frame

    DEFF Research Database (Denmark)

    Ramezani, Malek; Li, Shuhui; Golestan, Saeed

    2017-01-01

    -by-step graphical analysis and design approach for a three-phase stand-alone VSI system in the dq reference frame, which provides a clear systematic decoupling process to design the inner- and outer-loop current and voltage controllers, respectively. The closed-loop d- and q-axis output impedances of the stand......-alone VSI system by considering the coupling effects between axes are also formulated, modelled, and evaluated. The study investigates how the decoupling and compensating terms added in the current and voltage controllers affect the dynamic performance and output dq impedances of the VSI system. Simulation...... and hardware results verify the effectiveness of the graphic design and analysis strategy....

  9. Enhanced current and voltage regulators for stand-alone applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback decoupling permits to achieve a better dynamic response for Voltage Source in stand-alone applications. The design of current and voltage regulators is performed in the discrete-time domain since it provides better accuracy and allows direct pole placement. As the attainable...... bandwidth of the current loop is mainly limited by computational and PWM delays, a lead compensator structure is proposed to overcome this limitation. The design of the voltage regulator is based on the Nyquist criterion, verifying to guarantee a high sensitivity peak. Discrete-time domain implementation...

  10. Study of a stand alone power system based on a photovoltaic field, an electrolyser and a fuel cell: test bench and modelling; Etude d'un systeme autonome de production d'energie couplant un champ photovoltaique, un electrolyseur et une pile a combustible: realisation d'un banc d'essai et modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Busquet, S.

    2003-12-01

    Our energetic future has to be based on non-polluting energies with long-term resources. Renewable energies are the best candidates but as their production is intermittent, storage way is necessary as well efficient as environmentally friendly. Coupled an electrolyser and a fuel cell allows to store electricity in gas form and furthermore to produce heat energy. The goal of this work is to evaluate performances of a stand-alone power system, producing electricity and heat, coupling a photovoltaic field and a hydrogen storage system, made of an electrolyser, a gas storage unit and a fuel cell. Hydrogen is the unique way to store electricity. To complete this task, two tools have been developed: a 3,6 kW test bench and a simulation tool. To select the test bench, a bibliographic study enables to collect the necessary information to size and to choice the system and its components. The low availability of components adapted to our application, forces us to create new devices (electrolyser, fuel cell, power management unit). The test bench is automatic and safe. Experimental analysis evaluates the efficiency of the hydrogen storage system, determining the different losses occurring in each component. Modifications are proposed to increase the performances of the storage system. The simulation tool enables to plan the operating of the test bench for a fixed load and place. This model can simulate any system based on experimental data of each component. Simulation results enable to characterise the functioning of the test bench in a stand-alone operation, to determine its performances and to evaluate the influence of the different losses. (author)

  11. Magnetic field measurements near stand-alone transformer stations.

    Science.gov (United States)

    Kandel, Shaiela; Hareuveny, Ronen; Yitzhak, Nir-Mordechay; Ruppin, Raphael

    2013-12-01

    Extremely low-frequency (ELF) magnetic field (MF) measurements around and above three stand-alone 22/0.4-kV transformer stations have been performed. The low-voltage (LV) cables between the transformer and the LV switchgear were found to be the major source of strong ELF MFs of limited spatial extent. The strong fields measured above the transformer stations support the assessment method, to be used in future epidemiological studies, of classifying apartments located right above the transformer stations as highly exposed to MFs. The results of the MF measurements above the ground around the transformer stations provide a basis for the assessment of the option of implementing precautionary procedures.

  12. Stand-alone photovoltaic system: study of a modular concept with distributed communication and control units; Systeme photovoltaique autonome: etude d'une structure modulaire a gestion repartie

    Energy Technology Data Exchange (ETDEWEB)

    Neusser, A.

    2004-09-15

    This thesis concerns an innovative photovoltaic system concept, which is modular am where the standardisation of all of the components is possible. Lead-acid batteries tare used to store the energy. The main objective of this project is the improvement of the battery management process in the system. As the batteries are the weak point of the system, a new battery charger is developed aiming at a longer life-span and a homogeneous ageing rate for all of them. This charger permits energy exchanges, which are co-ordinated by a communication system. We use a DC/DC converter as power electronics for battery charging. PSpice simulations and tests verify its performance. Simulations with Matlab Simulink show the auto-equalization tendency of the chosen battery management method. In addition, an experimentation under real conditions validates the beneficial effect on the state of health of the batteries. (author)

  13. Test of the scroll pump in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly. JFCU scroll pump test and result, JFCU stand alone tritium test 2

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takumi; Konishi, Satoshi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Ohira, Shigeru [and others

    1993-03-01

    In the JAERI Fuel Cleanup System (JFCU), major subsystem of the TSTA simulated fusion fuel loop, a Normetex Scroll pump is used to pump out hydrogen isotope gases from the palladium diffuser. The characteristics of the pump was measured with hydrogen isotopes and helium, in a closed loop. Compression ratio and ultimate pressure were strongly affected by the delivery pressure and the species of the gas. Particularly with H{sub 2} and D{sub 2}, additional metal bellows pump was proved to be needed to satisfy the process requirement. For hydrogen isotopes, pumping characteristics improves with the mass of the gas and similar pumping capability was obtained with pure T{sub 2} and helium. (author).

  14. On-board power supply with fuel cells. Liquid gas fuelled system enables stand alone off-grid power supply; Bordstromversorgung mit Brennstoffzellen. Fluessiggas-betriebenes System ermoeglicht autarke, netzunabhaengige Stromversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Hirn, Gerhard

    2011-07-01

    You reach your final destination for the day, switch off the engine of your motorhome, and sit back to enjoy the view. Cicadas chirping and the music of nature are the only sounds you can hear. And then, far away from the nearest mains outlet, you get your laptop out to check your emails and plan your route for the next day. Quietly, and with low emissions, the electrical power you need is produced by your own on-board fuel cell generator. You know that with the fuel cell, your vehicle battery will always be fully charged. Now that the funded research and testing work has been done, fuel cell hybrid systems are ready for the market. (orig.)

  15. Lossy Data Aggregation with Network Coding in Stand-Alone Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Madsen, Tatiana Kozlova

    2011-01-01

    in chemical plants, etc. Given resource constrained operation of a sensor network where the nodes are battery powered and buffer sizes are limited, efficient methods for in-network data storage abd it subsequent fast and reliable transmission to a gateway is desirable. To save scarse resources and to prolong......This work focuses on a special type of wireless sensor networks (WSNs) that we refer to as a stand alone network. These netwoks operate in harsh and extreme environments where data collection is done only occasionally. Typical examples include habitat monitoring systems, monitoring systems...

  16. A Simple Sizing Algorithm for Stand-Alone PV/Wind/Battery Hybrid Microgrids

    Directory of Open Access Journals (Sweden)

    Jing Li

    2012-12-01

    Full Text Available In this paper, we develop a simple algorithm to determine the required number of generating units of wind-turbine generator and photovoltaic array, and the associated storage capacity for stand-alone hybrid microgrid. The algorithm is based on the observation that the state of charge of battery should be periodically invariant. The optimal sizing of hybrid microgrid is given in the sense that the life cycle cost of system is minimized while the given load power demand can be satisfied without load rejection. We also report a case study to show the efficacy of the developed algorithm.

  17. State Feedback Decoupling with In-Loop Lead Compensator in Stand-Alone VSIs

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; de Sousa Ribeiro, Luiz Antonio

    2016-01-01

    The performance of current and voltage regulators during transients and steady-state is of primary concern for power converters intended for stand-alone applications. Dynamics performance and command tracking capability are enhanced by actively decoupling the controlled states variables. To further...... widen the current loop bandwidth while still preserving a well-damped system a lead compensator structure on the forward loop is proposed. A 3 kHz bandwidth with 0.707 damping factor is achieved for the inner current controller. Accordingly, also the voltage regulator bandwidth can be widen, thus...

  18. A sizing method for stand-alone PV installations with variable demand

    Energy Technology Data Exchange (ETDEWEB)

    Posadillo, R. [Grupo de Investigacion en Energias y Recursos Renovables, Dpto. de Fisica Aplicada, E.P.S., Universidad de Cordoba, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Lopez Luque, R. [Grupo de Investigacion de Fisica Para las Energias y Recursos Renovables, Dpto. de Fisica Aplicada, Edificio C2 Campus de Rabanales, 14071 Cordoba (Spain)

    2008-05-15

    The practical applicability of the considerations made in a previous paper to characterize energy balances in stand-alone photovoltaic systems (SAPV) is presented. Given that energy balances were characterized based on monthly estimations, the method is appropriate for sizing installations with variable monthly demands and variable monthly panel tilt (for seasonal estimations). The method presented is original in that it is the only method proposed for this type of demand. The method is based on the rational utilization of daily solar radiation distribution functions. When exact mathematical expressions are not available, approximate empirical expressions can be used. The more precise the statistical characterization of the solar radiation on the receiver module, the more precise the sizing method given that the characterization will solely depend on the distribution function of the daily global irradiation on the tilted surface H{sub g{beta}}{sub i}. This method, like previous ones, uses the concept of loss of load probability (LLP) as a parameter to characterize system design and includes information on the standard deviation of this parameter ({sigma}{sub LLP}) as well as two new parameters: annual number of system failures (f) and the standard deviation of annual number of system failures ({sigma}{sub f}). This paper therefore provides an analytical method for evaluating and sizing stand-alone PV systems with variable monthly demand and panel inclination. The sizing method has also been applied in a practical manner. (author)

  19. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  20. Design of a Stand-Alone Photovoltaic Model for Home Lightings and Clean Environment

    Energy Technology Data Exchange (ETDEWEB)

    Ani, Vincent Anayochukwu, E-mail: vincent_ani@yahoo.com [Department of Electronic Engineering, University of Nigeria, Nsukka (Nigeria)

    2016-01-11

    This paper gives a well-documented health risk of fuel-based lighting (kerosene lamps and fuel-powered generators) and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs) using two different battery types (Rolls Surrette 6CS25PS and Hoppecke 10 OpzS 1000) on; (i) judicious power consumption, (ii) normal power consumption, and (iii) excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedures were used to demonstrate the best solution (reliability at the lowest lifecycle cost). Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with EEL options (judicious power consumption, normal power consumption, and excess power consumption).

  1. Design of a Stand-Alone Photovoltaic (PV Models for Home Lightings and Clean Environment

    Directory of Open Access Journals (Sweden)

    Vincent Anayochukwu Ani

    2016-01-01

    Full Text Available This paper gives a well-documented health risks of fuel-based lighting (kerosene lamps and fuel-powered generators and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs using two different battery types (Rolls Surrette 6CS25PS and hoppecke 10 OpzS 1000 on; i judicious power consumption, ii normal power consumption, iii excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedure were used to demonstrate the best solution (reliability at the lowest lifecycle cost. Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with energy efficient lighting options (judicious power consumption, normal power consumption, and excess power consumption.

  2. Design of a Stand-Alone Photovoltaic Model for Home Lightings and Clean Environment

    International Nuclear Information System (INIS)

    Ani, Vincent Anayochukwu

    2016-01-01

    This paper gives a well-documented health risk of fuel-based lighting (kerosene lamps and fuel-powered generators) and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs) using two different battery types (Rolls Surrette 6CS25PS and Hoppecke 10 OpzS 1000) on; (i) judicious power consumption, (ii) normal power consumption, and (iii) excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedures were used to demonstrate the best solution (reliability at the lowest lifecycle cost). Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with EEL options (judicious power consumption, normal power consumption, and excess power consumption).

  3. Size optimization of stand-alone photovoltaic (PV) room air conditioners

    International Nuclear Information System (INIS)

    Chen, Chien-Wei; Zahedi, A.

    2006-01-01

    Sizing of a stand-alone PV system determines the main cost of the system. PV electricity cost is determined by the amount of solar energy received, hence the actual climate and weather conditions such as solar irradiance and ambient temperature affect the size required and cost of the system. Air conditioning demand also depends on the weather conditions. Therefore, sizing a PV powered air conditioner must consider the characteristics of local climate and temperature. In this paper, sizing procedures and special considerations for air conditioning under Melbourne's climatic conditions is presented. The reliability of various PV-battery size combinations is simulated by MATLAB. As a result, excellent system performance can be predicated.(Author)

  4. An Analysis of Stand-alone GPS Quality and Simulated GNSS Quality for Road Pricing

    DEFF Research Database (Denmark)

    Zabic, Martina; Nielsen, Otto Anker

    2006-01-01

    Use of GPS for road pricing has often been suggested as the way of creating more efficient charging strategies than existing systems based on cordon lines or time use. In Denmark, Copenhagen participated with the AKTA project in the PRoGRESS programme, sponsored by the EU. The major part...... of the AKTA project was to equip 500 cars with GPS receivers. The paper presents the methods and results from a study of GPS quality in relation to road pricing in a dense urban area. The collected data from 500 cars over a two-year period in the Copenhagen region was analyzed in order to determine whether...... the stand alone GPS quality and reliability is adequate for implementation of an operational road pricing system in Copenhagen. The results from the analysis show that the satellite availability in Copenhagen is not sufficient to form the basis for a reliable operational road pricing system. The narrow...

  5. Sizing, techno-economic and generation management analysis of a stand alone photovoltaic power unit including storage devices

    International Nuclear Information System (INIS)

    Jallouli, Rihab; Krichen, Lotfi

    2012-01-01

    Due to the mismatch between the load demand and the intermittent solar energy, a stand-alone photovoltaic-hydrogen system and an optimal control scheme are designed to maintain the high system efficiency. Based on meteorological and the load demand data, a system sizing technique is proposed to establish the minimum capacity of the system components, which are a photovoltaic (PV) panel, a proton exchange membrane fuel cell (PEMFC), a battery bank and an alkaline electrolyzer (Elz). An accurate energy management scheme that is utilized during power transfer is proposed to meet the economic requirements. Case studies are used to verify the efficiency of the energy management strategy and system sizing technique. Simulation results illustrate a simple solution to the design and processing of stand-alone PV-hydrogen (PV-H 2 ) systems. -- Highlights: ► We study a stand alone PV-hydrogen system comprising renewable devices. ► A PV generator, a battery bank, a fuel cell and an electrolyzer are modeled. ► Power management taking into account the economic arrangement and the operating conditions to ensure energy availability is proposed.

  6. Stand-alone version of the 11kW Gaia wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.; Blaabjerg, F.

    2004-09-15

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of the fast controllers of the unit. Controllers are designed and a prototype is built for testing. The report documents the performance of the prototype through measurements done on the full scale prototype installed in a test facility where it has been tested both as a standalone unit and in parallel with a diesel genset. For system wide power quality assessment and controller design a dynamic performance assessment model has been developed. (au)

  7. Clinical outcome of stand-alone ALIF compared to posterior instrumentation for degenerative disc disease

    DEFF Research Database (Denmark)

    Udby, Peter M.; Bech-Azeddine, Rachid

    2015-01-01

    The objective of the article was to: a) present results from a case cohort pilot study comparing stand-alone ALIF and TLIF and, b) review the literature on studies comparing the clinical outcome of stand-alone ALIF with posterior instrumentation including TLIF or PLIF, in patients with disabling...... low back pain resulting from degenerative disc disease. ALIF surgery has previously been linked with certain high risk complications and unfavorable long term fusion results. Newer studies suggest that stand-alone ALIF can possibly be advantageous compared to other types of posterior instrumented...

  8. Diagnostic value of the stand-alone synthetic image in digital breast tomosynthesis examinations.

    Science.gov (United States)

    Garayoa, Julia; Chevalier, Margarita; Castillo, Maria; Mahillo-Fernández, Ignacio; Amallal El Ouahabi, Najim; Estrada, Carmen; Tejerina, Alejandro; Benitez, Olivia; Valverde, Julio

    2018-02-01

    To demonstrate the non-inferiority of synthetic image (SI) mammography versus full-field digital mammography (FFDM) in breast tomosynthesis (DBT) examinations. An observational, retrospective, single-centre, multireader blinded study was performed, using 2384 images to directly compare SI and FFDM based on Breast Imaging Reporting and Data System (BIRADS) categorisation and visibility of radiological findings. Readers had no access to digital breast tomosynthesis slices. Multiple reader, multiple case (MRMC) receiver operating characteristic (ROC) methodology was used to compare the diagnostic performance of SI and FFDM images. The kappa statistic was used to estimate the inter-reader and intra-reader reliability. The area under the ROC curves (AUC) reveals the non-inferiority of SI versus FFDM based on BIRADS categorisation [difference between AUC (ΔAUC), -0.014] and lesion visibility (ΔAUC, -0.001) but the differences were not statistically significant (p=0.282 for BIRADS; p=0.961 for lesion visibility). On average, 77.4% of malignant lesions were detected with SI versus 76.5% with FFDM. Sensitivity and specificity of SI are superior to FFDM for malignant lesions scored as BIRADS 5 and breasts categorised as BIRADS 1. SI is not inferior to FFDM when DBT slices are not available during image reading. SI can replace FFDM, reducing the dose by 45%. • Stand-alone SI demonstrated performance not inferior for lesion visibility as compared to FFDM. • Stand-alone SI demonstrated performance not inferior for lesion BIRADS categorisation as compared to FFDM. • Synthetic images provide important dose savings in breast tomosynthesis examinations.

  9. A Case Study of Control and Improved Simplified Swarm Optimization for Economic Dispatch of a Stand-Alone Modular Microgrid

    Directory of Open Access Journals (Sweden)

    Xianyong Zhang

    2018-03-01

    Full Text Available Due to the complex configuration and control framework, the conventional microgrid is not cost-effective for engineering applications with small or medium capacity. A stand-alone modular microgrid with separated AC bus and decentralized control strategy is proposed in this paper. Each module is a self-powered system, which consists of wind and solar power, a storage battery, load and three-port converter. The modules are interconnected by three-port converters to form the microgrid. Characteristics, operation principle, control of the modular microgrid and the three-port converter are analyzed in detail. Distributed storage batteries enable power exchanges among modules to enhance economic returns. Economic dispatch of the stand-alone modular microgrid is a mixed-integer programming problem. A day-ahead operation optimization model including fuel cost, battery operation cost, and power transmission cost is established. Because there are so many constraints, it is difficult to produce a feasible solution and even more difficult to have an improved solution. An improved simplified swarm optimization (iSSO method is therefore proposed. The iSSO scheme designs the new update mechanism and survival of the fittest policy. The experimental results from the demonstration project on DongAo Island reflect the effectiveness of the stand-alone modular microgrid and the economic dispatch strategy based on the iSSO method.

  10. Five-year durability of stand-alone interspinous process decompression for lumbar spinal stenosis

    Directory of Open Access Journals (Sweden)

    Nunley PD

    2017-09-01

    Full Text Available Pierce D Nunley,1 Vikas V Patel,2 Douglas G Orndorff,3 William F Lavelle,4 Jon E Block,5 Fred H Geisler6 1Spine Institute of Louisiana, Shreveport, LA, 2The Spine Center, University of Colorado Hospital, Denver, CO, 3Spine Colorado, Mercy Regional Hospital, Durango, CO, 4Upstate Bone and Joint Center, East Syracuse, NY, 5Independent Consultant, San Francisco, CA, 6Independent Consultant, Chicago, IL, USA Background: Lumbar spinal stenosis is the most common indication for spine surgery in older adults. Interspinous process decompression (IPD using a stand-alone spacer that functions as an extension blocker offers a minimally invasive treatment option for intermittent neurogenic claudication associated with spinal stenosis.Methods: This study evaluated the 5-year clinical outcomes for IPD (Superion® from a randomized controlled US Food and Drug Administration (FDA noninferiority trial. Outcomes included Zurich Claudication Questionnaire (ZCQ symptom severity (ss, physical function (pf, and patient satisfaction (ps subdomains, leg and back pain visual analog scale (VAS, and Oswestry Disability Index (ODI.Results: At 5 years, 84% of patients (74 of 88 demonstrated clinical success on at least two of three ZCQ domains. Individual ZCQ domain success rates were 75% (66 of 88, 81% (71 of 88, and 90% (79 of 88 for ZCQss, ZCQpf, and ZCQps, respectively. Leg and back pain success rates were 80% (68 of 85 and 65% (55 of 85, respectively, and the success rate for ODI was 65% (57 of 88. Percentage improvements over baseline were 42%, 39%, 75%, 66%, and 58% for ZCQss, ZCQpf, leg and back pain VAS, and ODI, respectively (all P<0.001. Within-group effect sizes were classified as very large for four of five clinical outcomes (ie, >1.0; all P<0.0001. Seventy-five percent of IPD patients were free from reoperation, revision, or supplemental fixation at their index level at 5 years.Conclusion: After 5 years of follow-up, IPD with a stand-alone spacer provides

  11. Methanol production via pressurized entrained flow biomass gasification – Techno-economic comparison of integrated vs. stand-alone production

    International Nuclear Information System (INIS)

    Andersson, Jim; Lundgren, Joakim; Marklund, Magnus

    2014-01-01

    The main objective with this work was to investigate techno-economically the opportunity for integrated gasification-based biomass-to-methanol production in an existing chemical pulp and paper mill. Three different system configurations using the pressurized entrained flow biomass gasification (PEBG) technology were studied, one stand-alone plant, one where the bark boiler in the mill was replaced by a PEBG unit and one with a co-integration of a black liquor gasifier operated in parallel with a PEBG unit. The cases were analysed in terms of overall energy efficiency (calculated as electricity-equivalents) and process economics. The economics was assessed under the current as well as possible future energy market conditions. An economic policy support was found to be necessary to make the methanol production competitive under all market scenarios. In a future energy market, integrating a PEBG unit to replace the bark boiler was the most beneficial case from an economic point of view. In this case the methanol production cost was reduced in the range of 11–18 Euro per MWh compared to the stand-alone case. The overall plant efficiency increased approximately 7%-units compared to the original operation of the mill and the non-integrated stand-alone case. In the case with co-integration of the two parallel gasifiers, an equal increase of the system efficiency was achieved, but the economic benefit was not as apparent. Under similar conditions as the current market and when methanol was sold to replace fossil gasoline, co-integration of the two parallel gasifiers was the best alternative based on received IRR. - Highlights: • Techno-economic results regarding integration of methanol synthesis processes in a pulp and paper mill are presented. • The overall energy efficiency increases in integrated methanol production systems compared to stand-alone production units. • The economics of the integrated system improves compared to stand-alone alternatives. • Tax

  12. PV-Battery Sizing for Stand-Alone Lighting Applications

    OpenAIRE

    Herteleer, Bert; Cappelle, Jan; Appels, Reinhart; Lefevre, Buvana; Driesen, Johan; Catthoor, Francky

    2013-01-01

    This paper presents a follow-up and addition to a system sizing spreadsheet, detailed in [An autonomous photovoltaic system sizing program for office applications in Africa], with a focus on sizing or verifying the employability of an off-grid PV-battery system for night lighting. A dimensionless criterion, the Battery Usable Fraction UF_batt is defined, which aids both the calculations of systems and allows an approximate comparison of batteries, regardless of the employed battery chemistry....

  13. Performance evaluation of stand alone hybrid PV-wind generator

    International Nuclear Information System (INIS)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-01-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand

  14. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  15. Deterrents on the Over Utilisation of Stand Alone Photovoltaic (PV ...

    African Journals Online (AJOL)

    At inception of the programme, systems were either undersized, or over utilised as clients did not reveal their usage needs in an attempt to reduce costs. This resulted in battery failures and other system breakdowns. The NPVREP categorised systems in order to alleviate the problem of under sizing and/or over utilization of ...

  16. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  17. Key factors for the implementation of successful, stand-alone village electrification schemes in Peru

    Science.gov (United States)

    Sanchez-Campos, Teodoro

    The hypothesis of this work is that there are social, financial, technical, managerial institutional and political key factors that may either support or prevent the success of small stand alone energy systems in rural areas. This research work aims at contributing to the identification of such factors and study their relevance to the performance and sustainability of stand alone energy systems in rural areas; to meet its purpose, a wide range of literature was reviewed including rural electrification programmes and projects, research and development projects on access to electricity in rural areas, impact studies and others, and a field research survey was done the Andes and Upper Jungle regions in Peru. Nineteen possible critical factors were identified, thirteen with relevance at the local context (the community or village), and six with relevance at the national (or wider) context. From literature review it was found that the possible local critical factors were relevant only to four categories of factors instead of the six considered initially (i.e. social, financial, technological and managerial): the other two categories, political and institutional were found to be more relevant to the national context, therefore those were included in the group of possible critical factors of wider context. A series of questionnaires were designed to collect field data information, which was later used to analyse and establish the relation of each identified factor with the success of the systems studied. The survey research was implemented in 14 villages, 7 with small diesel sets and 7 with small hydropower schemes, all spread in the Andes and Upper Jungle of Peru, which were carefully selected to be representative of regions with isolated stand alone systems and with different socioeconomic background. Out of the 13 possible critical factors of local context, it was found that only 3 are really critical, the others are important but not critical; one of them (technical

  18. On the economics of stand-alone renewable hybrid power plants in remote regions

    International Nuclear Information System (INIS)

    Petrakopoulou, Fontina

    2016-01-01

    Highlights: • Economic evaluation of three renewable hybrid power plants for off-grid operation. • The high electricity cost of remote regions increases the competitiveness of renewable energy. • The proposed plants are economically viable when compared to the existing situation. • The zero direct emissions of the plants constitute an additional advantage of the plants. - Abstract: In recent years ever more examples of regions that have managed to achieve or orientate themselves toward renewable energy sufficiency are emerging. However, actions to create energy autonomy are mainly the result of isolated activities and they are less driven from fully organized movements. In addition, total energy independence without the support of a centralized electrical grid is yet to be achieved. The objectives of this work are to investigate the associated costs of stand-alone renewable hybrid power plants on a Greek island and compare them to the cost of the currently used fossil-fuel-based conventional plant. The plants examined here are designed to fully cover the electricity needs of the island. Islands may face numerous energy problems and rely heavily on foreign and environmentally-harmful fuels. It is shown that the relatively high cost of electricity of such a remote region can increase the competitiveness and promote the wider incorporation of technologies based on renewable energy sources that may, in other cases, seem economically inferior to business-as-usual energy solutions.

  19. MIRNA-DISTILLER: a stand-alone application to compile microRNA data from databases

    Directory of Open Access Journals (Sweden)

    Jessica K. Rieger

    2011-07-01

    Full Text Available MicroRNAs (miRNA are small non-coding RNA molecules of ~22 nucleotides which regulate large numbers of genes by binding to seed sequences at the 3’-UTR of target gene transcripts. The target mRNA is then usually degraded or translation is inhibited, although thus resulting in posttranscriptional down regulation of gene expression at the mRNA and/or protein level. Due to the bioinformatic difficulties in predicting functional miRNA binding sites, several publically available databases have been developed that predict miRNA binding sites based on different algorithms. The parallel use of different databases is currently indispensable, but highly uncomfortable and time consuming, especially when working with numerous genes of interest. We have therefore developed a new stand-alone program, termed MIRNA-DISTILLER, which allows to compile miRNA data for given target genes from public databases. Currently implemented are TargetScan, microCosm, and miRDB, which may be queried independently, pairwise, or together to calculate the respective intersections. Data are stored locally for application of further analysis tools including freely definable biological parameter filters, customized output-lists for both miRNAs and target genes, and various graphical facilities. The software, a data example file and a tutorial are freely available at http://www.ikp-stuttgart.de/content/language1/html/10415.asp

  20. MIRNA-DISTILLER: A Stand-Alone Application to Compile microRNA Data from Databases.

    Science.gov (United States)

    Rieger, Jessica K; Bodan, Denis A; Zanger, Ulrich M

    2011-01-01

    MicroRNAs (miRNA) are small non-coding RNA molecules of ∼22 nucleotides which regulate large numbers of genes by binding to seed sequences at the 3'-untranslated region of target gene transcripts. The target mRNA is then usually degraded or translation is inhibited, although thus resulting in posttranscriptional down regulation of gene expression at the mRNA and/or protein level. Due to the bioinformatic difficulties in predicting functional miRNA binding sites, several publically available databases have been developed that predict miRNA binding sites based on different algorithms. The parallel use of different databases is currently indispensable, but highly uncomfortable and time consuming, especially when working with numerous genes of interest. We have therefore developed a new stand-alone program, termed MIRNA-DISTILLER, which allows to compile miRNA data for given target genes from public databases. Currently implemented are TargetScan, microCosm, and miRDB, which may be queried independently, pairwise, or together to calculate the respective intersections. Data are stored locally for application of further analysis tools including freely definable biological parameter filters, customized output-lists for both miRNAs and target genes, and various graphical facilities. The software, a data example file and a tutorial are freely available at http://www.ikp-stuttgart.de/content/language1/html/10415.asp.

  1. She stands alone: Pakistani woman film director, Shireen Pasha.

    Science.gov (United States)

    Mustafa, A

    1995-01-01

    This article describes the activities of film director Shireen Pasha in promoting truth in the mass media in Pakistan. Pasha is described as one who finds it inexcusable in a state-subsidized system that national problems of poverty are not aired openly. Pasha has pursued the goal of exposing the real lives of Pakistanis on film in contrast to the publicly aired segments of "pretty girls in nice drawing rooms." Foreign channels available through satellite communications technology are viewed by Pasha as inappropriate with regard to people's needs and uncreative. Pakistan began with one channel, PTV, which recently refused to air her documentary on living conditions in Pakistan's rural areas "The Travelogue Pakistan." "The Walled City of Lahore" was her film about life in the old city. Both films poetically depicted the honor of humans and their struggle to stay alive. Some of her documentaries are made to show the value of indigenous skills, centuries old know-how, and traditions, regardless of the poverty. Pasha is described as fighting with PTV management over use of resources. Pasha desires to invest in training people to do documentaries or be more field-oriented rather than investing in equipment. Pasha joined PTV in 1975 and left in 1990. Pasha is recognized for her isolation as a woman in the business world, her commitment to exposing remote cultures and truth, and the odds she must confront in attaining her goals. Pasha is committed to doing extensive research, usually conducted during the summer months, in order to construct a credible story line that is produced usually during the winter months. One model of film story line is defined as one where women are portrayed as starting from an indigenous skill or knowledge and shifting to a greater position of power and control over their lives. Pasha believes that people who make films have the responsibility to evoke a reaction in people and to offer solutions. Two acclaimed films, which were supported by

  2. Analysis and control of induction generator supplying stand-alone AC loads employing a Matrix Converter

    Directory of Open Access Journals (Sweden)

    Sumedha Mahajan

    2017-04-01

    Full Text Available This paper proposes a Capacitor Excited Induction Generator (CEIG-Matrix Converter (MC system for feeding stand-alone AC loads. The variable output voltage magnitude and frequency from CEIG is converted into a constant voltage magnitude and frequency at the load terminals by controlling MC using Space Vector Modulation (SVM technique. This single-stage MC is turned up as a good alternative for the proposed system against commonly used AC/DC/AC two stage power converters. The configuration and implementation of the closed-loop control scheme employing dSPACE 1103 real time controller have been fully described in the paper. The proposed closed-loop controller regulates the AC load voltage irrespective of changes in the prime mover speed and load. A method for predetermining the steady-state performance of the proposed system has been developed and described with relevant analytical expressions. The effectiveness of the proposed system is exemplified through simulation results for various operating conditions. The proposed control technique is further validated using an experimental setup developed in the laboratory.

  3. An optimized Fuzzy Logic Controller by Water Cycle Algorithm for power management of Stand-alone Hybrid Green Power generation

    International Nuclear Information System (INIS)

    Sarvi, Mohammad; Avanaki, Isa Nasiri

    2015-01-01

    Highlights: • A new method to improve the performance of renewable power management is proposed. • The proposed method is based on Fuzzy Logic optimized by the Water Cycle Algorithm. • The proposed method characteristics are compared with two other methods. • The comparisons confirm that the proposed method is robust and effectiveness one. - Abstract: This paper aims to improve the power management system of a Stand-alone Hybrid Green Power generation based on the Fuzzy Logic Controller optimized by the Water Cycle Algorithm. The proposed Stand-alone Hybrid Green Power consists of wind energy conversion and photovoltaic systems as primary power sources and a battery, fuel cell, and Electrolyzer as energy storage systems. Hydrogen is produced from surplus power generated by the wind energy conversion and photovoltaic systems of Stand-alone Hybrid Green Power and stored in the hydrogen storage tank for fuel cell later using when the power generated by primary sources is lower than load demand. The proposed optimized Fuzzy Logic Controller based power management system determines the power that is generated by fuel cell or use by Electrolyzer. In a hybrid system, operation and maintenance cost and reliability of the system are the important issues that should be considered in studies. In this regard, Water Cycle Algorithm is used to optimize membership functions in order to simultaneously minimize the Loss of Power Supply Probability and operation and maintenance. The results are compared with the particle swarm optimization and the un-optimized Fuzzy Logic Controller power management system to prove that the proposed method is robust and effective. Reduction in Loss of Power Supply Probability and operation and maintenance, are the most advantages of the proposed method. Moreover the level of the State of Charge of the battery in the proposed method is higher than other mentioned methods which leads to increase battery lifetime.

  4. Stand-alone excitation synchronous wind power generators with power flow management strategy

    Directory of Open Access Journals (Sweden)

    Tzuen-Lih Chern

    2014-09-01

    Full Text Available This study presents a stand-alone excitation synchronous wind power generator (SESWPG with power flow management strategy (PFMS. The rotor speed of the excitation synchronous generator tracks the utility grid frequency by using servo motor tracking technologies. The automatic voltage regulator governs the exciting current of generator to achieve the control goals of stable voltage. When wind power is less than the needs of the consumptive loading, the proposed PFMS increases motor torque to provide a positive power output for the loads, while keeping the generator speed constant. Conversely, during the periods of wind power greater than output loads, the redundant power of generator production is charged to the battery pack and the motor speed remains constant with very low power consumption. The advantage of the proposed SESWPG is that the generator can directly output stable alternating current (AC electricity without using additional DC–AC converters. The operation principles with software simulation for the system are described in detail. Experimental results of a laboratory prototype are shown to verify the feasibility of the system.

  5. Design of a reliable and low-cost stand-alone micro hydropower station

    Energy Technology Data Exchange (ETDEWEB)

    Kusakana, K.; Munda, J.L. [Tshwane Univ. of Technology, Pretoria (South Africa)

    2008-07-01

    A stand-alone micro-hydropower station was presented. The plant was comprised of a squirrel cage induction machine coupled to a Kaplan water turbine. Power converters were used to control the variable frequency and voltage outputs of the generator caused by variations in water flow. The hydropower plant was installed a farm in the Kwazulu-Natal region of South Africa, and was designed to provide electricity in relation to the low power demand of users in the region as well as according to the site's hydrology and topology. Load forecasts for the 8 houses using the system were conducted. A generator with a higher output than the average power needed to feed the load was selected in order to ensure load supply during peak demand. The system was designed to shore energy generated during off-peak periods in batteries. An AC-DC-AC converter was used as an interface between the generator and the load in order to ensure voltage and frequency stabilization. Simulations of plant components were conducted to demonstrate output power supply during water flow variations. Results of the modelling study indicated that power converters are needed to stabilize generator outputs. The hydropower design is a cost-effective means of supplying power to low-income households. 10 refs., 2 tabs., 7 figs.

  6. Performance and Simulation of a Stand-alone Parabolic Trough Solar Thermal Power Plant

    Science.gov (United States)

    Mohammad, S. T.; Al-Kayiem, H. H.; Assadi, M. K.; Gilani, S. I. U. H.; Khlief, A. K.

    2018-05-01

    In this paper, a Simulink® Thermolib Model has been established for simulation performance evaluation of Stand-alone Parabolic Trough Solar Thermal Power Plant in Universiti Teknologi PETRONAS, Malaysia. This paper proposes a design of 1.2 kW parabolic trough power plant. The model is capable to predict temperatures at any system outlet in the plant, as well as the power output produced. The conditions that are taken into account as input to the model are: local solar radiation and ambient temperatures, which have been measured during the year. Other parameters that have been input to the model are the collector’s sizes, location in terms of latitude and altitude. Lastly, the results are presented in graphical manner to describe the analysed variations of various outputs of the solar fields obtained, and help to predict the performance of the plant. The developed model allows an initial evaluation of the viability and technical feasibility of any similar solar thermal power plant.

  7. Can aqueous hydrogen peroxide be used as a stand-alone energy source?

    International Nuclear Information System (INIS)

    Disselkamp, Robert S.

    2010-01-01

    A novel electrochemical scheme to convert a stand-alone supply of aqueous hydrogen peroxide into a fuel cell-ready stream of hydrogen gas plus aqueous hydrogen peroxide is described. The electrochemical cell, consisting of a solid base and solid acid electrocatalyst, together with a proton exchange membrane, comprise the system that converts aqueous hydrogen peroxide into separate gas streams of oxygen and hydrogen. Aqueous hydrogen peroxide is contained in the anode compartment only and exists in the region where oxygen gas is formed, whereas the cathode compartment is where hydrogen gas is generated and therefore exists in a reduced state. A near zero theoretical over-potential can be achieved by the choice of basicity and acidity of the electrode materials. The primary cost of the electrochemical cell is electrode construction and the aqueous hydrogen peroxide energy storage compound. Additional research effort is required to experimentally validate the concept and explore the full economic impact should initial studies, based on the design presented here, prove promising. (author)

  8. Connecting embedded and stand-alone peer mentoring models to enhance student engagement

    Directory of Open Access Journals (Sweden)

    Rhys Cooper

    2018-03-01

    Full Text Available This paper outlines the Trident Student Mentoring Program that runs in the College of Engineering at Victoria University, Melbourne, Australia. The program offers both embedded and stand-alone models of peer mentoring services to the same cohort of first-year students. It shows that by forming strong links between these two types of peer mentoring models, the inherent challenges of both, such as low attendance rates in stand-alone models and short periods of peer to peer time in embedded models, are mitigated.

  9. "Candidatus Fokinia solitaria", a Novel "Stand-Alone" Symbiotic Lineage of Midichloriaceae (Rickettsiales.

    Directory of Open Access Journals (Sweden)

    Franziska Szokoli

    Full Text Available Recently, the family Midichloriaceae has been described within the bacterial order Rickettsiales. It includes a variety of bacterial endosymbionts detected in different metazoan host species belonging to Placozoa, Cnidaria, Arthropoda and Vertebrata. Representatives of Midichloriaceae are also considered possible etiological agents of certain animal diseases. Midichloriaceae have been found also in protists like ciliates and amoebae. The present work describes a new bacterial endosymbiont, "Candidatus Fokinia solitaria", retrieved from three different strains of a novel Paramecium species isolated from a wastewater treatment plant in Rio de Janeiro (Brazil. Symbionts were characterized through the full-cycle rRNA approach: SSU rRNA gene sequencing and fluorescence in situ hybridization (FISH with three species-specific oligonucleotide probes. In electron micrographs, the tiny rod-shaped endosymbionts (1.2 x 0.25-0.35 μm in size were not surrounded by a symbiontophorous vacuole and were located in the peripheral host cytoplasm, stratified in the host cortex in between the trichocysts or just below them. Frequently, they occurred inside autolysosomes. Phylogenetic analyses of Midichloriaceae apparently show different evolutionary pathways within the family. Some genera, such as "Ca. Midichloria" and "Ca. Lariskella", have been retrieved frequently and independently in different hosts and environmental surveys. On the contrary, others, such as Lyticum, "Ca. Anadelfobacter", "Ca. Defluviella" and the presently described "Ca. Fokinia solitaria", have been found only occasionally and associated to specific host species. These last are the only representatives in their own branches thus far. Present data do not allow to infer whether these genera, which we named "stand-alone lineages", are an indication of poorly sampled organisms, thus underrepresented in GenBank, or represent fast evolving, highly adapted evolutionary lineages.

  10. Linguistic and Structural Analyses of Stand-Alone Literature Reviews: Seventy-Five Years of Change

    Science.gov (United States)

    Wright, Heidi Rachel

    2016-01-01

    The purpose of this dissertation is to offer a multifaceted overview of stand-alone literature reviews. These texts, literature reviews published unattached to research articles, have existed for centuries but remained largely unstudied by linguists. Thus, the goal of this project is to present these reviews' situational, grammatical, and…

  11. Assessment of Stand-Alone Displays for Time Management in a Creativity-Driven Learning Environment

    DEFF Research Database (Denmark)

    Frimodt-Møller, Søren

    2017-01-01

    This paper considers the pros and cons of stand-alone displays, analog (e.g. billboards, blackboards, whiteboards, large pieces of paper etc.) as well as digital (e.g. large shared screens, digital whiteboards or similar), as tools for time management processes in a creativity-driven learning...

  12. Stand-alone version of the 11kW Gaia wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.

    2004-01-01

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of thefast controllers of the unit. Controllers...... assessment and controller design a dynamic performance assessment model has been developed....

  13. A maximum power point tracking scheme for a 1kw stand-alone ...

    African Journals Online (AJOL)

    A maximum power point tracking scheme for a 1kw stand-alone solar energy based power supply. ... Nigerian Journal of Technology ... A method for efficiently maximizing the output power of a solar panel supplying a load or battery bus under ...

  14. Modelling of fluid-solid interaction using two stand-alone codes

    CSIR Research Space (South Africa)

    Grobler, Jan H

    2010-01-01

    Full Text Available A method is proposed for the modelling of fluid-solid interaction in applications where fluid forces dominate. Data are transferred between two stand-alone codes: a dedicated computational fluid dynamics (CFD) code capable of free surface modelling...

  15. Comparison of pulp-mill-integrated hydrogen production from gasified black liquor with stand-alone production from gasified biomass

    International Nuclear Information System (INIS)

    Andersson, E.; Harvey, S.

    2007-01-01

    When gasified black liquor is used for hydrogen production, significant amounts of biomass must be imported. This paper compares two alternative options for producing hydrogen from biomass: (A) pulp-mill-integrated hydrogen production from gasified back liquor; and (B) stand-alone production of hydrogen from gasified biomass. The comparison assumes that the same amount of biomass that is imported in Alternative A is supplied to a stand-alone hydrogen production plant and that the gasified black liquor in Alternative B is used in a black liquor gasification combined cycle (BLGCC) CHP unit. The comparison is based upon equal amounts of black liquor fed to the gasifier, and identical steam and power requirements for the pulp mill. The two systems are compared on the basis of total CO 2 emission consequences, based upon different assumptions for the reference energy system that reflect different societal CO 2 emissions reduction target levels. Ambitions targets are expected to lead to a more CO 2 -lean reference energy system, in which case hydrogen production from gasified black liquor (Alternative A) is best from a CO 2 emissions' perspective, whereas with high CO 2 emissions associated with electricity production, hydrogen from gasified biomass and electricity from gasified black liquor (Alternative B) is preferable. (author)

  16. The Use of Artificial Neural Networks for Forecasting the Electric Demand of Stand-Alone Consumers

    Science.gov (United States)

    Ivanin, O. A.; Direktor, L. B.

    2018-05-01

    The problem of short-term forecasting of electric power demand of stand-alone consumers (small inhabited localities) situated outside centralized power supply areas is considered. The basic approaches to modeling the electric power demand depending on the forecasting time frame and the problems set, as well as the specific features of such modeling, are described. The advantages and disadvantages of the methods used for the short-term forecast of the electric demand are indicated, and difficulties involved in the solution of the problem are outlined. The basic principles of arranging artificial neural networks are set forth; it is also shown that the proposed method is preferable when the input information necessary for prediction is lacking or incomplete. The selection of the parameters that should be included into the list of the input data for modeling the electric power demand of residential areas using artificial neural networks is validated. The structure of a neural network is proposed for solving the problem of modeling the electric power demand of residential areas. The specific features of generation of the training dataset are outlined. The results of test modeling of daily electric demand curves for some settlements of Kamchatka and Yakutia based on known actual electric demand curves are provided. The reliability of the test modeling has been validated. A high value of the deviation of the modeled curve from the reference curve obtained in one of the four reference calculations is explained. The input data and the predicted power demand curves for the rural settlement of Kuokuiskii Nasleg are provided. The power demand curves were modeled for four characteristic days of the year, and they can be used in the future for designing a power supply system for the settlement. To enhance the accuracy of the method, a series of measures based on specific features of a neural network's functioning are proposed.

  17. The eBioKit, a stand-alone educational platform for bioinformatics.

    Science.gov (United States)

    Hernández-de-Diego, Rafael; de Villiers, Etienne P; Klingström, Tomas; Gourlé, Hadrien; Conesa, Ana; Bongcam-Rudloff, Erik

    2017-09-01

    Bioinformatics skills have become essential for many research areas; however, the availability of qualified researchers is usually lower than the demand and training to increase the number of able bioinformaticians is an important task for the bioinformatics community. When conducting training or hands-on tutorials, the lack of control over the analysis tools and repositories often results in undesirable situations during training, as unavailable online tools or version conflicts may delay, complicate, or even prevent the successful completion of a training event. The eBioKit is a stand-alone educational platform that hosts numerous tools and databases for bioinformatics research and allows training to take place in a controlled environment. A key advantage of the eBioKit over other existing teaching solutions is that all the required software and databases are locally installed on the system, significantly reducing the dependence on the internet. Furthermore, the architecture of the eBioKit has demonstrated itself to be an excellent balance between portability and performance, not only making the eBioKit an exceptional educational tool but also providing small research groups with a platform to incorporate bioinformatics analysis in their research. As a result, the eBioKit has formed an integral part of training and research performed by a wide variety of universities and organizations such as the Pan African Bioinformatics Network (H3ABioNet) as part of the initiative Human Heredity and Health in Africa (H3Africa), the Southern Africa Network for Biosciences (SAnBio) initiative, the Biosciences eastern and central Africa (BecA) hub, and the International Glossina Genome Initiative.

  18. Stand alone solution for generation and storage of hydrogen and electric energy

    International Nuclear Information System (INIS)

    Gany, Alon; Elitzur, Shani; Valery

    2015-01-01

    A novel method enabling safe, simple, and controllable production, storage, and use of hydrogen as well as compact electric energy storage and generation via hydrogen- oxygen fuel cells has been developed. The technology indicates, in our opinion, a significant milestone in the search for practical utilization of hydrogen as an alternative energy source. It consists of an original thermal-chemical treatment / activation of aluminum powders to react spontaneously with water to produce hydrogen at regular conditions according to the reaction Al+3H 2 O=Al (OH) 3 +3/2H 2 . Only about 1-2% of lithium, based activator is applied, and any type of water including tap water, sea water and waste water may be used, making the method attractive for variety of applications. 11% of hydrogen compared to the aluminum mass can be obtained, and our experiments reveal 90% reaction yield and more. The technology has a clear advantage over batteries, providing specific electric energy of over 2 kW h/kg Al, 5-10 times greater than that of commonly used lithium-ion batteries. Combined with a fuel cell it may be particularly beneficial for stand-alone electric power generators, where there is no access to the grid. Such applications include emergency generators (e.g., in hospitals), electricity backup systems, and power generation in remote communication posts. Automotive applications may be considered as well. The technology provides green electric energy and quiet operation as well as additional heat energy resulting mainly from the exothermic aluminum-water reaction. (full text)

  19. GOssTo: a stand-alone application and a web tool for calculating semantic similarities on the Gene Ontology.

    Science.gov (United States)

    Caniza, Horacio; Romero, Alfonso E; Heron, Samuel; Yang, Haixuan; Devoto, Alessandra; Frasca, Marco; Mesiti, Marco; Valentini, Giorgio; Paccanaro, Alberto

    2014-08-01

    We present GOssTo, the Gene Ontology semantic similarity Tool, a user-friendly software system for calculating semantic similarities between gene products according to the Gene Ontology. GOssTo is bundled with six semantic similarity measures, including both term- and graph-based measures, and has extension capabilities to allow the user to add new similarities. Importantly, for any measure, GOssTo can also calculate the Random Walk Contribution that has been shown to greatly improve the accuracy of similarity measures. GOssTo is very fast, easy to use, and it allows the calculation of similarities on a genomic scale in a few minutes on a regular desktop machine. alberto@cs.rhul.ac.uk GOssTo is available both as a stand-alone application running on GNU/Linux, Windows and MacOS from www.paccanarolab.org/gossto and as a web application from www.paccanarolab.org/gosstoweb. The stand-alone application features a simple and concise command line interface for easy integration into high-throughput data processing pipelines. © The Author 2014. Published by Oxford University Press.

  20. Stand-Alone Microgrid Inverter Controller Design for Nonlinear, Unbalanced Load with Output Transformer

    Directory of Open Access Journals (Sweden)

    Jae-Uk Lim

    2018-04-01

    Full Text Available This paper proposes a technique that compensates for unbalance and nonlinearity in microgrid inverters with power transformers operating in stand-alone mode. When a microgrid inverter is operating in stand-alone mode, providing high-quality power is very important. When an unbalanced, nonlinear load is connected, zero sequence current and negative sequence current occur, which leads to an unbalanced output voltage. This paper examines why the zero sequence component occurs differently depending on the structure of a three-phase transformer connected to the inverter output terminal, and it proposes a method for controlling the zero sequence component. It also uses a resonant controller to remove the harmonics that correspond to the negative sequence component and the nonlinear component. The proposed elements were verified by a Powersim (PSIM simulation.

  1. Online retrieval of patient information by asynchronous communication between general purpose computer and stand-alone personal computer

    International Nuclear Information System (INIS)

    Tsutsumi, Reiko; Takahashi, Kazuei; Sato, Toshiko; Komatani, Akio; Yamaguchi, Koichi

    1988-01-01

    Asynchronous communication was made between host (FACOM M-340) and personal computer (OLIBETTIE S-2250) to get patient's information required for RIA test registration. The retrieval system consists of a keyboad input of six numeric codes, patient's ID, and a real time reply containing six parameters for the patient. Their identified parameters are patient's name, sex, date of birth (include area), department, and out- or inpatient. Linking this program to RIA registration program for individual patient, then, operator can input name of RIA test requested. Our simple retrieval program made a useful data network between different types of host and stand-alone personal computers, and enabled us accurate and labor-saving registration for RIA test. (author)

  2. Independence and Product Systems

    OpenAIRE

    Skeide, Michael

    2003-01-01

    Starting from elementary considerations about independence and Markov processes in classical probability we arrive at the new concept of conditional monotone independence (or operator-valued monotone independence). With the help of product systems of Hilbert modules we show that monotone conditional independence arises naturally in dilation theory.

  3. Systematic Multi-variable H-infinity Control Design for Primary Frequency Regulation in Stand-alone Microgrids with High Penetration of Renewable Energy Sources

    OpenAIRE

    Lam , Quang Linh; Bratcu , Antoneta Iuliana; Riu , Delphine

    2016-01-01

    International audience; In this paper, a systematic design of a robust multi-variable control structure for primary frequency regulation in microgrids with high rate of renewable source penetration is proposed. The considered microgrid represents a diesel-photovoltaic-supercapacitor hybrid power generation system operating in stand-alone mode. The proposed control structure relies on a two-level architecture: classical PI-based current tracking controllers are placed on the low control level ...

  4. SoC-Based Output Voltage Control for BESS with a Lithium-Ion Battery in a Stand-Alone DC Microgrid

    Directory of Open Access Journals (Sweden)

    Seung-Yeong Yu

    2016-11-01

    Full Text Available This paper proposes a new DC output voltage control for a battery energy storage system (BESS with a lithium-ion battery based on the state of charge (SoC. The proposed control scheme was verified through computer simulations for a typical stand-alone DC microgrid, which consists of a BESS, photovoltaic (PV panel, engine generator (EG, and DC load. A scaled hardware prototype for a stand-alone DC microgrid was set up in the lab, in which the proposed control scheme was loaded in a DSP controller. The experimental results were compared with the simulation results for performance verification. The proposed control scheme provides relatively lower variation of the DC grid voltage than the conventional droop control.

  5. Modified Chaos Particle Swarm Optimization-Based Optimized Operation Model for Stand-Alone CCHP Microgrid

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2017-07-01

    Full Text Available The optimized dispatch of different distributed generations (DGs in stand-alone microgrid (MG is of great significance to the operation’s reliability and economy, especially for energy crisis and environmental pollution. Based on controllable load (CL and combined cooling-heating-power (CCHP model of micro-gas turbine (MT, a multi-objective optimization model with relevant constraints to optimize the generation cost, load cut compensation and environmental benefit is proposed in this paper. The MG studied in this paper consists of photovoltaic (PV, wind turbine (WT, fuel cell (FC, diesel engine (DE, MT and energy storage (ES. Four typical scenarios were designed according to different day types (work day or weekend and weather conditions (sunny or rainy in view of the uncertainty of renewable energy in variable situations and load fluctuation. A modified dispatch strategy for CCHP is presented to further improve the operation economy without reducing the consumers’ comfort feeling. Chaotic optimization and elite retention strategy are introduced into basic particle swarm optimization (PSO to propose modified chaos particle swarm optimization (MCPSO whose search capability and convergence speed are improved greatly. Simulation results validate the correctness of the proposed model and the effectiveness of MCPSO algorithm in the optimized operation application of stand-alone MG.

  6. Input of biomass in stand-alone small-scale installations for power generation. Calculation of the financial gap

    International Nuclear Information System (INIS)

    Van Tilburg, X.; De Vries, H.J.; Pfeiffer, A.E.; Beekes, M.; Cleijne, J.W.

    2005-09-01

    A number of new initiatives in which bio-oil is used in stand-alone plants for power generation has been reviewed. The question to be answered is whether the reference case for stand alone biomass projects based on burning of wood chips can still be considered representative for the costs and benefits in this category. ECN, in cooperation with KEMA, have determined the financial gap between the costs and benefits of projects in which bio-oil is used in stand alone plants for power generation. The ranges and reference case for bio-oil in stand alone applications show that these projects have a substantially lower financial gap than the current reference case based on wood chips [nl

  7. Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line

    Science.gov (United States)

    Malla, S. G.; Bhende, C. N.

    2014-10-01

    The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.

  8. Imagery rescripting as a stand-alone treatment for patients with social phobia: a case series.

    Science.gov (United States)

    Frets, Petra G; Kevenaar, Ciska; van der Heiden, Colin

    2014-03-01

    The majority of patients with social phobia reports experiencing negative images, usually linked to memories of earlier aversive social experiences. Several studies have indicated that such negative self-imagery appears to have a causal role in maintaining social phobia, which suggests that interventions aimed at dealing with these images could be beneficial in the treatment of social phobia. One potentially powerful approach is imagery rescripting (IR), a clinical intervention that focuses on changing the meaning and impact of unpleasant memories. In the treatment of social phobia IR was only used as part of a broader cognitive-behavioral treatment package. However, we propose that IR alone might also be an effective treatment for this anxiety disorder. The present study reports an initial evaluation of the application of IR as a stand-alone treatment for six adult outpatients presenting with social phobia. A single case series using an A-B replication across patients design was employed. Following a no-treatment baseline period, IR was delivered weekly and patients were followed up for 3 and 6 months. For all patients, substantial reductions were obtained on all outcome measures at post-treatment, and gains were largely maintained at 6-months follow-up. The generalizability of the effects of IR for social phobia is limited by the small number of patients treated by only one therapist. The results of this preliminary case series suggest that IR as a stand alone treatment is an apparently effective intervention in the treatment of patients with social phobia, and indicate that controlled evaluation of its efficacy might be worthwhile. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. A Meta-Analytic Review of Stand-Alone Interventions to Improve Body Image.

    Directory of Open Access Journals (Sweden)

    Jessica M Alleva

    Full Text Available Numerous stand-alone interventions to improve body image have been developed. The present review used meta-analysis to estimate the effectiveness of such interventions, and to identify the specific change techniques that lead to improvement in body image.The inclusion criteria were that (a the intervention was stand-alone (i.e., solely focused on improving body image, (b a control group was used, (c participants were randomly assigned to conditions, and (d at least one pretest and one posttest measure of body image was taken. Effect sizes were meta-analysed and moderator analyses were conducted. A taxonomy of 48 change techniques used in interventions targeted at body image was developed; all interventions were coded using this taxonomy.The literature search identified 62 tests of interventions (N = 3,846. Interventions produced a small-to-medium improvement in body image (d+ = 0.38, a small-to-medium reduction in beauty ideal internalisation (d+ = -0.37, and a large reduction in social comparison tendencies (d+ = -0.72. However, the effect size for body image was inflated by bias both within and across studies, and was reliable but of small magnitude once corrections for bias were applied. Effect sizes for the other outcomes were no longer reliable once corrections for bias were applied. Several features of the sample, intervention, and methodology moderated intervention effects. Twelve change techniques were associated with improvements in body image, and three techniques were contra-indicated.The findings show that interventions engender only small improvements in body image, and underline the need for large-scale, high-quality trials in this area. The review identifies effective techniques that could be deployed in future interventions.

  10. Optimal sizing of grid-independent hybrid photovoltaic–battery power systems for household sector

    International Nuclear Information System (INIS)

    Bianchi, M.; Branchini, L.; Ferrari, C.; Melino, F.

    2014-01-01

    Highlights: • A feasibility study on a stand-alone solar–battery power generation system is carried out. • An in-house developed calculation code able to estimate photovoltaic panels behaviour is described. • The feasibility of replacing grid electricity with hybrid system is examined. • Guidelines for optimal photovoltaic design are given. • Guidelines for optimal storage sizing in terms of batteries number and capacity are given. - Abstract: The penetration of renewable sources into the grid, particularly wind and solar, have been increasing in recent years. As a consequence, there have been serious concerns over reliable and safety operation of power systems. One possible solution, to improve grid stability, is to integrate energy storage devices into power system network: storing energy produced in periods of low demand to later use, ensuring full exploitation of intermittent available sources. Focusing on stand-alone photovoltaic (PV) energy system, energy storage is needed with the purpose of ensuring continuous power flow, to minimize or, if anything, to neglect electrical grid supply. A comprehensive study on a hybrid stand-alone photovoltaic power system using two different energy storage technologies has been performed. The study examines the feasibility of replacing electricity provided by the grid with hybrid system to meet household demand. In particular, this paper presents first results for photovoltaic (PV)/battery (B) hybrid configuration. The main objective of this paper is focused on PV/B system, to recommend hybrid system optimal design in terms of PV module number, PV module tilt, number and capacity of batteries to minimize or, if possible, to neglect grid supply. This paper is the early stage of a theoretical and experimental study in which two different hybrid power system configurations will be evaluated and compared: (i) PV/B system and (ii) PV/B/fuel cell (FC) system. The aim of the overall study will be the definition of the

  11. [Clinical application of stand-alone MC+PEEK cage in the anterior cervical fusion].

    Science.gov (United States)

    Jiang, Bing; Cao, Yan-Qing; Pan, Hong; Zhu, Cheng-Run; Zhang, Xiao-Jun; Tao, Yue-Feng; Liu, Zhen

    2015-04-01

    To explore the effect of clinical application of stand-alone MC+PEEK cage in anterior cervical fusion. From January 2011 to January 2014,50 patients were treated with the MC+PEEK cage filled with autogenous cancellous illic-bone graft after anterior cervical discectomy. There were 22 patients with cervical spondylosis,26 patients with traumatic cervical disc herniation, 2 patients with cervical instability in these patients. There were 32 males and 18 females, aged from 30 to 79 years old with an average of 53.30 years old. There were 32 patients with single segment, 15 patients with double segments and 3 patients with three segments. Cervical AP and lateral and the flexion-extension X-rays were regularly taken in order to assess the cervical physiological curvature, the graft fusion and internal fixation related complications. Nerve function, clinical effect and bone fusion were respectively evaluated according to Japan Orthopedic Association (JOA), Otani grade and Suk method. All patients were followed up from 6 to 36 months with an average of 20 months. No correlated surgical complications were found and all patients obtained bony fusion with an average time of 4.30 months. JOA score had significantly improvement after surgery (P cervical fusion can obtain satisfactory clinical effect with less operation injury and reduce the complications. It is a better fusion method in anterior cervical fusion.

  12. An intelligent stand-alone ultrasonic device for monitoring local structural damage: implementation and preliminary experiments

    International Nuclear Information System (INIS)

    Pertsch, Alexander; Kim, Jin-Yeon; Wang, Yang; Jacobs, Laurence J

    2011-01-01

    Continuous structural health monitoring has the potential to significantly improve the safety management of aged, in-service civil structures. In particular, monitoring of local damage growth at hot-spot areas can help to prevent disastrous structural failures. Although ultrasonic nondestructive evaluation (NDE) has proved to be effective in monitoring local damage growth, conventional equipment and devices are usually bulky and only suitable for scheduled human inspections. The objective of this research is to harness the latest developments in embedded hardware and wireless communication for developing a stand-alone, compact ultrasonic device. The device is directed at the continuous structural health monitoring of civil structures. Relying on battery power, the device possesses the functionalities of high-speed actuation, sensing, signal processing, and wireless communication. Integrated with contact ultrasonic transducers, the device can generate 1 MHz Rayleigh surface waves in a steel specimen and measure response waves. An envelope detection algorithm based on the Hilbert transform is presented for efficiently determining the peak values of the response signals, from which small surface cracks are successfully identified

  13. Single anterior cervical discectomy and fusion (ACDF) using self- locking stand-alone polyetheretherketone (PEEK) cage: evaluation of pain and health-related quality of life.

    Science.gov (United States)

    Kapetanakis, Stylianos; Thomaidis, Tryfon; Charitoudis, George; Pavlidis, Pavlos; Theodosiadis, Panagiotis; Gkasdaris, Grigorios

    2017-09-01

    Anterior cervical discectomy and fusion (ACDF) constitutes the conventional treatment of cervical disc herniation due to degenerative disc disease (DDD). ACDF with plating presents a variety of complications postoperatively and stand-alone cages are thought to be a promising alternative. The aim of this study was firstly, to analyze prospectively collected data from a sample of patients treated with single ACDF using C-Plus self-locking stand-alone PEEK cage system, without the use of plates or screws, in order to evaluate pain levels of patients, utilizing Neck and Arm Pain scale as an expression of visual analogue scale (VAS). Secondly, we aimed to evaluate health-related quality of life, via the short-form 36 (SF-36) and Neck Disability Index (NDI). Thirty-six patients (19 male and 17 female) with mean age 49.6±7 years old who underwent successful single ACDF using self-locking stand-alone PEEK cage for symptomatic cervical DDD were selected for the study. Neck and Arm pain, as well as SF-36 and NDI were estimated preoperatively and 1, 3, 6, and 12 months postoperatively. Patients underwent preoperative and postoperative clinical, neurological and radiological evaluation. The clinical and radiological outcomes were satisfactory after a minimum 1-year follow-up. All results were statistically important (P<0.05), excluding improvement in NDI measured between 6 and 12 months. SF-36, Neck Pain, as well as Arm Pain featured gradual and constant improvement during follow-up, with best scores presenting at 12 months after surgery, while NDI reached its best at 6 months postoperatively. Generally, all scores showed improvement postoperatively during the different phases of the follow-up. Subsequently, ACDF using C-Plus cervical cage constitutes an effective method for cervical disc herniation treatment, in terms of postoperative improvement on pain levels and health-related quality of life and a safe alternative to the conventional method of treatment for cervical DDD.

  14. 49 CFR 1109.4 - Mandatory mediation in rate cases to be considered under the stand-alone cost methodology.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Mandatory mediation in rate cases to be considered... § 1109.4 Mandatory mediation in rate cases to be considered under the stand-alone cost methodology. (a) A... methodology must engage in non-binding mediation of its dispute with the railroad upon filing a formal...

  15. Stand-Alone Ethics, Social Responsibility, and Sustainability Course Requirements: A Snapshot from Australia and New Zealand

    Science.gov (United States)

    Rundle-Thiele, Sharyn R.; Wymer, Walter

    2010-01-01

    This article analyzes the extent to which Australian and New Zealand marketing educators use dedicated or stand-alone courses to equip students with alternative views of business. A census of marketing programs in degree-granting universities was conducted. Program brochures were obtained via the Internet and were content analyzed. This study…

  16. Stand-Alone Lateral Interbody Fusion for the Treatment of Low-Grade Degenerative Spondylolisthesis

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2012-01-01

    Full Text Available The purpose of this paper was to investigate the stand-alone lateral interbody fusion as a minimally invasive option for the treatment of low-grade degenerative spondylolisthesis with a minimum 24-month followup. Prospective nonrandomized observational single-center study. 52 consecutive patients (67.6±10 y/o; 73.1% female; 27.4±3.4 BMI with single-level grade I/II single-level degenerative spondylolisthesis without significant spine instability were included. Fusion procedures were performed as retroperitoneal lateral transpsoas interbody fusions without screw supplementation. The procedures were performed in average 73.2 minutes and with less than 50cc blood loss. VAS and Oswestry scores showed lasting improvements in clinical outcomes (60% and 54.5% change, resp.. The vertebral slippage was reduced in 90.4% of cases from mean values of 15.1% preoperatively to 7.4% at 6-week followup (P<0.001 and was maintained through 24 months (7.1%, P<0.001. Segmental lordosis (P<0.001 and disc height (P<0.001 were improved in postop evaluations. Cage subsidence occurred in 9/52 cases (17% and 7/52 cases (13% spine levels needed revision surgery. At the 24-month evaluation, solid fusion was observed in 86.5% of the levels treated. The minimally invasive lateral approach has been shown to be a safe and reproducible technique to treat low-grade degenerative spondylolisthesis.

  17. Study on unitized inverter with photovoltaic grid-connected and stand-alone functions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haining; Su, Jianhui; Ding, Ming [Hefei University of Technology, Hefei (China)

    2008-07-01

    The main circuit and algorithm of unitized single phase inverter are presented, in which photovoltaic (PV) grid-connected algorithm, independency sine inverter algorithm and storage battery charge administer are all integrated basing on DSP (Digital Signal Processor). The control system identifies utility failure initiatively and then switches to independency power supply automatically. The methods of charging battery are multiform. Basing on material term to use utility or solar array to charge can optimize charge efficiency, assure the capacitance of battery and prolong life-span of battery. In addition, some results are offered basing on the prototype of a 2.5kW single phase inverter. (orig.)

  18. Energetic and financial investigation of a stand-alone solar-thermal Organic Rankine Cycle power plant

    International Nuclear Information System (INIS)

    Tzivanidis, Christos; Bellos, Evangelos; Antonopoulos, Kimon A.

    2016-01-01

    Highlights: • A stand-alone solar driven Organic Rankine Cycle is optimized parametrically. • The system is optimized energetically and financially. • Nine working fluids are tested with cyclohexane to be the most suitable. • A collecting area of 25,000 m"2 parabolic trough collectors is the optimum solution. • The maximum IRR is 13.46% and the payback period is about 9 years. - Abstract: The use of solar thermal energy for electricity production is a clean and sustainable way to cover the increasing energy needs of our society. The most mature technology for capturing solar energy in high temperature levels is the parabolic trough collectors (PTC). In this study, an Organic Rankine Cycle (ORC) coupled with PTC is analyzed parametrically in order to be optimized financially and energetically. The first step is the thermodynamic investigation of the ORC by using various working fluids. The second step is the energetic and financial investigation of the total system which includes the solar field, the storage tank and the ORC module. By testing many combinations of collecting areas and storage tank volumes, finally cyclohexane proved to be the most suitable working fluid for producing 1 MW_e_l with PTC. Specifically, in the optimum situation a solar field of 25,000 m"2 with storage tank of about 300 m"3 leads to a payback period of 9 years and to an internal rate of return (IRR) equal to 13.46%. Moreover, an economic comparison for different commercial collectors is presented, with Eurotrough ET-150 being the financially optimum solution for this case study.

  19. [Biomechanicsl evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass-ceramic on the human cervical spine].

    Science.gov (United States)

    Korinth, M C; Moersch, S; Ragoss, C; Schopphoff, E

    2003-12-01

    Recently, there has been a rapid increase in the use of cervical spine interbody fusion cages, differing in design and biomaterial used, in competition to autologous iliac bone graft and bone cement (PMMA). Limited biomechanical differences in primary stability, as well as advantages and disadvantages of each cage or material have been investigated in studies, using an in vitro human cervical spine model. 20 human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or PMMA after discectomy. Non-destructive biomechanical testing was performed, including flexion/extension and lateral bending using a spine testing apparatus. Three-dimensional segmental range of motion (ROM) was evaluated using an ultrasound measurement system. ROM increased more in flexion/extension and lateral bending after PMMA fusion (26.5%/36.1%), then after implantation of the Ecopore-cage (8.1%/7.8%). In this first biomechanical in vitro examination of a new porous ceramic bone replacement material a) the feasibility and reproducibility of biomechanical cadaveric cervical examination and its applicability was demonstrated, b) the stability of the ceramic cage as a stand alone interbody cage was confirmed in vitro, and c) basic information and knowledge for our intended biomechanical and histological in vivo testing, after implantation of Ecopore in cervical sheep spines, were obtained.

  20. Development of stand-alone risk assessment software for optimized maintenance planning of power plant facilities

    International Nuclear Information System (INIS)

    Choi, Woo Sung; Song, Gee Wook; Kim, Bum Shin; Chang, Sung Ho; Lee, Sang Min

    2015-01-01

    Risk-Risk-based inspection (RBI) has been developed in order to identify risky equipment that can cause major accidents or damages in large-scale plants. This assessment evaluates the equipment's risk, categorizes their priorities based on risk level, and then determines the urgency of their maintenance or allocates maintenance resources. An earlier version of the risk-based assessment software is already installed within the equipment management system; however, the assessment is based on examination by an inspector, and the results can be influenced by his subjective judgment, rather than assessment being based on failure probability. Moreover, the system is housed within a server, which limits the inspector's work space and time, and such a system can be used only on site. In this paper, the development of independent risk-based assessment software is introduced; this software calculates the failure probability by an analytical method, and analyzes the field inspection results, as well as inspection effectiveness. It can also operate on site, since it can be installed on an independent platform, and has the ability to generate an I/O function for the field inspection results regarding the period for an optimum maintenance cycle. This program will provide useful information not only to the field users who are participating in maintenance, but also to the engineers who need to decide whether to extend the life cycle of the power machinery or replace only specific components

  1. A review of three stand-alone topical thrombins for surgical hemostasis.

    Science.gov (United States)

    Cheng, Christine M; Meyer-Massetti, Carla; Kayser, Steven R

    2009-01-01

    Topical thrombins are active hemostatic agents that can be used to minimize blood loss during surgery. Before 2007, the only topical thrombins available were derived from bovine plasma. Antibody formation to bovine thrombin and/or factor V, with subsequent risk of cross-reactivity with human factor V, and hemorrhagic complications associated with human factor-V deficiencies have been described in case reports of surgeries in which bovine thrombins were used. This risk is now included in the boxed warning section of the bovine thrombin prescribing information. In 2007 and 2008, 2 new topical thrombins from nonbovine sources received approval for use from the US Food and Drug Administration. The 3 active topical thrombins that are currently marketed are bovine plasma-derived thrombin, human plasma-derived thrombin, and human recombinant thrombin. The purpose of this review was to evaluate the literature on the efficacy and safety of topical thrombins and discuss the pharmacoeconomic considerations associated with their use. PubMed, EMBASE, and International Pharmaceutical Abstracts were searched for relevant papers published in English through October 10,2008, using the terms thrombin, human recombinant thrombin, bovine thrombin, plasma derived thrombin, and topical thrombin. Manufacturer-provided materials were also reviewed. Abstracts and unpublished data, as well as evaluations of sealants, adhesives, glues, and other hemostats that contain thrombin mixed with fibrinogen and other clotting factors, were excluded. Four randomized, double-blind studies involving the active, stand-alone topical thrombins were found. The bovine thrombin involved in these studies was the predecessor to the currently marketed, highly purified bovine formulation. No studies comparing the human products, studies involving the highly purified bovine preparation, or placebo-controlled studies involving bovine thrombin were found. In a Phase III comparison of human recombinant thrombin and

  2. A New Vector Control of Brushless Doubly-Fed Inductor Generator With Transient Current Compensation for Stand-Alone Power Generation Applications

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Yu, Kailiang

    2018-01-01

    The stand-alone brushless doubly-fed induction generator (BDFIG) with the conventional control strategies suffers heavily from poor dynamic performance especially under heavy load disturbance. This paper presents a new vector control strategy of BDFIG for stand-alone power generation applications...... control strategies, and the results verify the satisfactory dynamic performance of the proposed strategy....

  3. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    Science.gov (United States)

    Wang, Huijun; Qu, Zheng; Tang, Shaofei; Pang, Mingqi; Zhang, Mingju

    2017-08-01

    In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  4. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huijun, E-mail: huijun024@gmail.com [School of Instrumentation Science and Opto-electronics Engineering, Beihang University (China); Qu, Zheng; Tang, Shaofei; Pang, Mingqi [School of Instrumentation Science and Opto-electronics Engineering, Beihang University (China); Zhang, Mingju [Shanghai Aerospace Control Technology Institute, Shanghai (China)

    2017-08-15

    Highlights: • One novel permanent magnet generator structure has been proposed to reduce voltage regulation ratio. • Finite element method and equivalent circuit methods are both employed to realize rapid generator design. • Design of experiment (DOE) method is used to optimize permanent magnet shape for reduce voltage waveform distortion. • The obtained analysis and experiment results verify the proposed design methods. - Abstract: In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  5. Simulation of a stand-alone renewable hydrogen system for residential supply

    Directory of Open Access Journals (Sweden)

    Martín Hervello

    2014-01-01

    Full Text Available La simulación por ordenador es un primer paso lógico previo a la realización de un proyecto de una construcción física además de ser una herramienta para el diseño de redes de energía. Los sistemas combinados son una solución para mejorar la disponibilidad de la energía suministrada con medios renovables. El principal inconveniente de las fuentes de energías renovables es su naturaleza altamente estacional, con grandes variaciones en el tiempo que pueden impedir el uso como base de consumo y limitar las horas de máxima demanda. El objetivo de este trabajo es realizar simulaciones para comprobar la autosuficiencia energética de una vivienda unifamiliar en base a energías renovables (eólica, solar-fotovoltaica utilizando como medio de almacenamiento un sistema híbrido de baterías e hidrógeno. Para ello se ha utilizado el programa Simulink®-Matlab® teniendo en cuenta los datos meteorológicos proporcionados por METEO-Galicia. El modelo puede ser aplicado para determinar la viabilidad de implementar una red energética en regiones específicas, y predecir el flujo de energía y el comportamiento del sistema durante todo el año.

  6. Photovoltaic OLED Driver for Low-Power Stand-Alone Light-to-Light Systems

    DEFF Research Database (Denmark)

    Ploug, Rasmus Overgaard; Knott, Arnold

    2016-01-01

    of a three-port-converter for this purpose optimized for the specifications for driving an Organic Light Emitting Diode (OLED) panel intended for lighting purposes. By using a three-port-converter, featuring shared components for each conversion mode, the converter reaches 97 % efficiency at 1.8 W during...... conversion from photovoltaic panel to the battery, and 97 % in the area 1.4 W to 2 W for power delivery to the OLED....

  7. Kajian Pemanfaatan Stand Alone Photovoltaic System Untuk Penerangan Jalan Umum Di Pulau Nusa Penida

    Directory of Open Access Journals (Sweden)

    I.W. Yudi Martha Wiguna

    2012-12-01

    Full Text Available   Nusa Penida merupakan sebuah pulau di tenggara pulau Bali dengan jumlah penduduk 47.448 jiwa. Ketersediaan daya pembangkit PLN di pulau Nusa Penida adalah sebesar 3200 kW. Dengan beban puncak sebesar 2530 kW maka cadangan listrik saat ini hanya sebesar 670 kW. Hal itu menyebabkan krisis listrik sangat terasa bagi masyarakat di daerah terpencil seperti di Pulau Nusa Penida. Saat ini salah satu solusi yang memungkinkan adalah mengembangkan sumber energi terbarukan. Di Pulau Nusa Penida sudah dikembangkan PLTS. Bahkan PLTS di Pulau Nusa Penida dikembangkan juga pada sistem penerangan jalan umum. Pada penelitian ini dilakukan analisa teknis dan biaya untuk mengetahui kelayakan Sistem PJU-TS tersebut. Pada analisa teknis dilakukan pengukuran output tegangan dan arus dari PV Panel ke Charger Controller, dari Charger Controller ke baterai dan ke beban. Analisa teknis menghasilkan bahwa penyebab kerusakan baterai karena kapasitas pembangkitan tidak sebanding dengan kebutuhan kapasitas beban PJU-TS. Dengan kapasitas baterai yang terus kecil akan menyebabkan kerusakan pada baterai. Selain itu karena usia baterai yang sudah lama. Analisa biaya dilakukan dengan 3 skenario dengan tingkat IRR yang ingin dicapai sebesar 10, 11, dan 12 %. Dihasilkan harga jual yang pantas untuk energi listrik PJU-TS Nusa Penida berkisar antara Rp.29.194,00 s/d Rp.31.585,00 per kWh.

  8. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    International Nuclear Information System (INIS)

    Wang, Huijun; Qu, Zheng; Tang, Shaofei; Pang, Mingqi; Zhang, Mingju

    2017-01-01

    Highlights: • One novel permanent magnet generator structure has been proposed to reduce voltage regulation ratio. • Finite element method and equivalent circuit methods are both employed to realize rapid generator design. • Design of experiment (DOE) method is used to optimize permanent magnet shape for reduce voltage waveform distortion. • The obtained analysis and experiment results verify the proposed design methods. - Abstract: In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  9. Maintenance of Segmental Lordosis and Disk Height in Stand-alone and Instrumented Extreme Lateral Interbody Fusion (XLIF).

    Science.gov (United States)

    Malham, Gregory M; Ellis, Ngaire J; Parker, Rhiannon M; Blecher, Carl M; White, Rohan; Goss, Ben; Seex, Kevin A

    2017-03-01

    A prospective single-surgeon nonrandomized clinical study. To evaluate the radiographic and clinical outcomes, by fixation type, in extreme lateral interbody fusion (XLIF) patients and provide an algorithm for determining patients suitable for stand-alone XLIF. XLIF may be supplemented with pedicle screw fixation, however, since stabilizing structures remain intact, it is suggested that stand-alone XLIF can be used for certain indications. This eliminates the associated morbidity, though subsidence rates may be elevated, potentially minimizing the clinical benefits. A fixation algorithm was developed after evaluation of patient outcomes from the surgeon's first 30 cases. This algorithm was used prospectively for 40 subsequent patients to determine the requirement for supplemental fixation. Preoperative, postoperative, and 12-month follow-up computed tomography scans were measured for segmental and global lumbar lordosis and posterior disk height. Clinical outcome measures included back and leg pain (visual analogue scale), Oswestry Disability Index (ODI), and SF-36 physical and mental component scores (PCS and MCS). Preoperatively to 12-month follow-up there were increases in segmental lordosis (7.9-9.4 degrees, P=0.0497), lumbar lordosis (48.8-55.2 degrees, P=0.0328), and disk height (3.7-5.5 mm, P=0.0018); there were also improvements in back (58.6%) and leg pain (60.0%), ODI (44.4%), PCS (56.7%), and MCS (16.1%) for stand-alone XLIF. For instrumented XLIF, segmental lordosis (7.6-10.5 degrees, P=0.0120) and disk height (3.5-5.6 mm, Plordosis decreased (51.1-45.8 degrees, P=0.2560). Back (49.8%) and leg pain (30.8%), ODI (32.3%), PCS (37.4%), and MCS (2.0%) were all improved. Subsidence occurred in 3 (7.5%) stand-alone patients. The XLIF treatment fixation algorithm provided a clinical pathway to select suitable patients for stand-alone XLIF. These patients achieved positive clinical outcomes, satisfactory fusion rates, with sustained correction of lordosis and

  10. Stand-Alone Personalized Normative Feedback for College Student Drinkers: A Meta-Analytic Review, 2004 to 2014.

    Directory of Open Access Journals (Sweden)

    Keri B Dotson

    Full Text Available Norms clarification has been identified as an effective component of college student drinking interventions, prompting research on norms clarification as a single-component intervention known as Personalized Normative Feedback (PNF. Previous reviews have examined PNF in combination with other components but not as a stand-alone intervention.To investigate the degree to which computer-delivered stand-alone personalized normative feedback interventions reduce alcohol consumption and alcohol-related harms among college students and to compare gender-neutral and gender-specific PNF.Electronic databases were searched systematically through November 2014. Reference lists were reviewed manually and forward and backward searches were conducted.Outcome studies that compared computer-delivered, stand-alone PNF intervention with an assessment only, attention-matched, or active treatment control and reported alcohol use and harms among college students.Between-group effect sizes were calculated as the standardized mean difference in change scores between treatment and control groups divided by pooled standard deviation. Within-group effect sizes were calculated as the raw mean difference between baseline and follow-up divided by pooled within-groups standard deviation.Eight studies (13 interventions with a total of 2,050 participants were included. Compared to control participants, students who received gender-neutral (dbetween = 0.291, 95% CI [0.159, 0.423] and gender-specific PNF (dbetween = 0.284, 95% CI [0.117, 0.451] reported greater reductions in drinking from baseline to follow-up. Students who received gender-neutral PNF reported 3.027 (95% CI [2.171, 3.882] fewer drinks per week at first follow-up and gender-specific PNF reported 3.089 (95% CI [0.992, 5.186] fewer drinks. Intervention effects were small for harms (dbetween = 0.157, 95% CI [0.037, 0.278].Computer-delivered PNF is an effective stand-alone approach for reducing college student

  11. Stand-Alone Personalized Normative Feedback for College Student Drinkers: A Meta-Analytic Review, 2004 to 2014.

    Science.gov (United States)

    Dotson, Keri B; Dunn, Michael E; Bowers, Clint A

    2015-01-01

    Norms clarification has been identified as an effective component of college student drinking interventions, prompting research on norms clarification as a single-component intervention known as Personalized Normative Feedback (PNF). Previous reviews have examined PNF in combination with other components but not as a stand-alone intervention. To investigate the degree to which computer-delivered stand-alone personalized normative feedback interventions reduce alcohol consumption and alcohol-related harms among college students and to compare gender-neutral and gender-specific PNF. Electronic databases were searched systematically through November 2014. Reference lists were reviewed manually and forward and backward searches were conducted. Outcome studies that compared computer-delivered, stand-alone PNF intervention with an assessment only, attention-matched, or active treatment control and reported alcohol use and harms among college students. Between-group effect sizes were calculated as the standardized mean difference in change scores between treatment and control groups divided by pooled standard deviation. Within-group effect sizes were calculated as the raw mean difference between baseline and follow-up divided by pooled within-groups standard deviation. Eight studies (13 interventions) with a total of 2,050 participants were included. Compared to control participants, students who received gender-neutral (dbetween = 0.291, 95% CI [0.159, 0.423]) and gender-specific PNF (dbetween = 0.284, 95% CI [0.117, 0.451]) reported greater reductions in drinking from baseline to follow-up. Students who received gender-neutral PNF reported 3.027 (95% CI [2.171, 3.882]) fewer drinks per week at first follow-up and gender-specific PNF reported 3.089 (95% CI [0.992, 5.186]) fewer drinks. Intervention effects were small for harms (dbetween = 0.157, 95% CI [0.037, 0.278]). Computer-delivered PNF is an effective stand-alone approach for reducing college student drinking and

  12. Grid parity analysis of stand-alone hybrid microgrids: A comparative study of Germany, Pakistan, South Africa and the United States

    Science.gov (United States)

    Siddiqui, Jawad M.

    Grid parity for alternative energy resources occurs when the cost of electricity generated from the source is lower than or equal to the purchasing price of power from the electricity grid. This thesis aims to quantitatively analyze the evolution of hybrid stand-alone microgrids in the US, Germany, Pakistan and South Africa to determine grid parity for a solar PV/Diesel/Battery hybrid system. The Energy System Model (ESM) and NREL's Hybrid Optimization of Multiple Energy Resources (HOMER) software are used to simulate the microgrid operation and determine a Levelized Cost of Electricity (LCOE) figure for each location. This cost per kWh is then compared with two distinct estimates of future retail electricity prices at each location to determine grid parity points. Analysis results reveal that future estimates of LCOE for such hybrid stand-alone microgrids range within the 35-55 cents/kWh over the 25 year study period. Grid parity occurs earlier in locations with higher power prices or unreliable grids. For Pakistan grid parity is already here, while Germany hits parity between the years 2023-2029. Results for South Africa suggest a parity time range of the years 2040-2045. In the US, places with low grid prices do not hit parity during the study period. Sensitivity analysis results reveal the significant impact of financing and the cost of capital on these grid parity points, particularly in developing markets of Pakistan and South Africa. Overall, the study helps conclude that variations in energy markets may determine the fate of emerging energy technologies like microgrids. However, policy interventions have a significant impact on the final outcome, such as the grid parity in this case. Measures such as eliminating uncertainty in policies and improving financing can help these grids overcome barriers in developing economies, where they may find a greater use much earlier in time.

  13. SSTAR, a Stand-Alone Easy-To-Use Antimicrobial Resistance Gene Predictor.

    Science.gov (United States)

    de Man, Tom J B; Limbago, Brandi M

    2016-01-01

    We present the easy-to-use Sequence Search Tool for Antimicrobial Resistance, SSTAR. It combines a locally executed BLASTN search against a customizable database with an intuitive graphical user interface for identifying antimicrobial resistance (AR) genes from genomic data. Although the database is initially populated from a public repository of acquired resistance determinants (i.e., ARG-ANNOT), it can be customized for particular pathogen groups and resistance mechanisms. For instance, outer membrane porin sequences associated with carbapenem resistance phenotypes can be added, and known intrinsic mechanisms can be included. Unique about this tool is the ability to easily detect putative new alleles and truncated versions of existing AR genes. Variants and potential new alleles are brought to the attention of the user for further investigation. For instance, SSTAR is able to identify modified or truncated versions of porins, which may be of great importance in carbapenemase-negative carbapenem-resistant Enterobacteriaceae. SSTAR is written in Java and is therefore platform independent and compatible with both Windows and Unix operating systems. SSTAR and its manual, which includes a simple installation guide, are freely available from https://github.com/tomdeman-bio/Sequence-Search-Tool-for-Antimicrobial-Resistance-SSTAR-. IMPORTANCE Whole-genome sequencing (WGS) is quickly becoming a routine method for identifying genes associated with antimicrobial resistance (AR). However, for many microbiologists, the use and analysis of WGS data present a substantial challenge. We developed SSTAR, software with a graphical user interface that enables the identification of known AR genes from WGS and has the unique capacity to easily detect new variants of known AR genes, including truncated protein variants. Current software solutions do not notify the user when genes are truncated and, therefore, likely nonfunctional, which makes phenotype predictions less accurate. SSTAR

  14. SedInConnect: a stand-alone, free and open source tool for the assessment of sediment connectivity

    Science.gov (United States)

    Crema, Stefano; Cavalli, Marco

    2018-02-01

    There is a growing call, within the scientific community, for solid theoretic frameworks and usable indices/models to assess sediment connectivity. Connectivity plays a significant role in characterizing structural properties of the landscape and, when considered in combination with forcing processes (e.g., rainfall-runoff modelling), can represent a valuable analysis for an improved landscape management. In this work, the authors present the development and application of SedInConnect: a free, open source and stand-alone application for the computation of the Index of Connectivity (IC), as expressed in Cavalli et al. (2013) with the addition of specific innovative features. The tool is intended to have a wide variety of users, both from the scientific community and from the authorities involved in the environmental planning. Thanks to its open source nature, the tool can be adapted and/or integrated according to the users' requirements. Furthermore, presenting an easy-to-use interface and being a stand-alone application, the tool can help management experts in the quantitative assessment of sediment connectivity in the context of hazard and risk assessment. An application to a sample dataset and an overview on up-to-date applications of the approach and of the tool shows the development potential of such analyses. The modelled connectivity, in fact, appears suitable not only to characterize sediment dynamics at the catchment scale but also to integrate prediction models and as a tool for helping geomorphological interpretation.

  15. Human microRNA target analysis and gene ontology clustering by GOmir, a novel stand-alone application.

    Science.gov (United States)

    Roubelakis, Maria G; Zotos, Pantelis; Papachristoudis, Georgios; Michalopoulos, Ioannis; Pappa, Kalliopi I; Anagnou, Nicholas P; Kossida, Sophia

    2009-06-16

    microRNAs (miRNAs) are single-stranded RNA molecules of about 20-23 nucleotides length found in a wide variety of organisms. miRNAs regulate gene expression, by interacting with target mRNAs at specific sites in order to induce cleavage of the message or inhibit translation. Predicting or verifying mRNA targets of specific miRNAs is a difficult process of great importance. GOmir is a novel stand-alone application consisting of two separate tools: JTarget and TAGGO. JTarget integrates miRNA target prediction and functional analysis by combining the predicted target genes from TargetScan, miRanda, RNAhybrid and PicTar computational tools as well as the experimentally supported targets from TarBase and also providing a full gene description and functional analysis for each target gene. On the other hand, TAGGO application is designed to automatically group gene ontology annotations, taking advantage of the Gene Ontology (GO), in order to extract the main attributes of sets of proteins. GOmir represents a new tool incorporating two separate Java applications integrated into one stand-alone Java application. GOmir (by using up to five different databases) introduces miRNA predicted targets accompanied by (a) full gene description, (b) functional analysis and (c) detailed gene ontology clustering. Additionally, a reverse search initiated by a potential target can also be conducted. GOmir can freely be downloaded BRFAA.

  16. Study on Soft Phase Locked Method to Solving the Synchronization Problem of Active Power Filter in Stand-alone Power Grid

    DEFF Research Database (Denmark)

    Zhuo, Fang; Wu, Longhui; Chen, Zhe

    2009-01-01

    on zero-cross detection can't work effectively in small rating stand-alone power grid. Then a soft phase locked loop with additional filter is proposed. It can lock the phase angle on to the positive sequence of fundamental voltage accurately and rapidly. It ensures the performance of APF applied...... in the small rating stand-alone power grid. Moreover, the soft phase locked loop is easy to be implemented in a Digital Signal Processor (DSP). Simulation and experimental results validate that the soft phase locked loop has satisfactory performance.......Traditional LC filters can't work stably in small rating stand-alone power grid. So active power filter (APF) is becoming an important tool to solve the power quality problem in small rating stand-alone power grid. In most current detection algorithm of APF, it needs a synchronizing signal. Firstly...

  17. Design of a small scale stand-alone solar thermal co-generation plant for an isolated region in Egypt

    International Nuclear Information System (INIS)

    Abdelhady, Suzan; Borello, Domenico; Tortora, Eileen

    2014-01-01

    Highlights: • In the selected area, connection to the grid is very difficult and expensive. • The integrated unsteady CSP/ORC system, was modeled TRNSYS. • Assuming a CSP of 200,000 m 2 , 6 MW e and 21.5 MW th can be obtained. • The energy is sufficient to feed more than 3,300 rural users and two big factories. • PER = 1.43, LCOE = 1.25 USD/kW h and the GHG emissions are reduced of 7300 toe/year. - Abstract: Most of Egypt’s population is concentrated in the Nile Valley (5% of Egypt’s area), while the western desert occupies an area of 50% of the total area of Egypt with a small number of inhabitants. The New Valley is the largest governorates in Egypt which occupies 45.8% of the total area of the Country and 65% of the Western Desert and it is the least densely populated governorate in Egypt. However, New Valley has started to receive the migrated people from the Nile valley and Delta region and the demand for the energy is continuously increasing. However, the rural area in New Valley still suffers from lack of access to energy services. The very high transmission losses and costs are the main challenges for electrification in this area. Then, it is worth to investigate the opportunities for distributed energy generation. This area of Egypt receives some of the highest solar radiation in the world (up to 3000 kW h per square meters per year), making it a prime location for use of this resource. In this study, performance and economic assessment of a small scale stand-alone solar thermal co-generation plant using diathermic oil is presented. This configuration is considered as a promising and sustainable solution to provide electricity and heat to an isolated area satisfying the local loads. Parabolic trough plant has been modeled in TRNSYS simulation environment integrated with the Solar Thermal Electric Components (STEC) model library. Both solar and power cycle performances have been modeled based on the solar energy data of the plant site. The

  18. Clinical and radiological outcome after anterior cervical discectomy and fusion with stand-alone empty polyetheretherketone (PEEK) cages.

    Science.gov (United States)

    Shiban, Ehab; Gapon, Karina; Wostrack, Maria; Meyer, Bernhard; Lehmberg, Jens

    2016-02-01

    To evaluate long-term results after one-, two-, and three-level anterior cervical discectomy and fusion (ACDF) with stand-alone empty polyetheretherketone (PEEK) cages. We performed a retrospective review of a consecutive patient cohort that underwent ACDF with stand-alone empty PEEK cages between 2007 and 2010 with a minimum follow-up of 12 months. Radiographic follow-up included static and flexion/extension radiographs. Changes in the operated segments were measured and compared to radiographs directly after surgery. Clinical outcome was evaluated by a physical examination, pain visual analog scale (VAS), and health-related quality of life (HRQL) using the EuroQOL questionnaire (EQ-5D). Analysis of associations between fusion, subsidence, cervical alignment, and clinical outcome parameters were performed. Of 407 consecutive cases, 318 met all inclusion criteria. Follow-up data were obtained from 265 (83 %) cases. The mean age at presentation was 55 years and 139 patients were male (52 %). In the sample, 127, 125, and 13 patients had one-, two-, and three-level surgeries, respectively; 132 (49 %) presented with spondylotic cervical myelopathy and 133 (50 %) with cervical radiculopathy. Fusion was achieved in 85, 95, and 94 % of segments in one-, two-, and three-level surgeries, respectively. Non-fusion was associated with higher VAS pain levels. Radiographic adjacent segment disease (ASD) was observed in 20, 29, and 15 % in one-, two-, and three-level surgeries, respectively. ASD was associated with lower HRQL. Subsidence was observed in 25, 27, and 15 % of segments in one-, two-, and three-level surgeries, respectively. However, this had no influence on clinical outcome. Follow-up operations for symptomatic adjacent disc disease and implant failure at index level were needed in 16 (6 %) and four (1.5 %) cases, respectively. Younger age was associated with better clinical outcome. Multilevel surgery favored better myelopathy outcomes and fusion reduced overall

  19. Feedforward control strategy for the state-decoupling Stand-alone UPS with LC output filter

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    . In order to further increase the load current disturbance rejection capability of the state-decoupling in UPS system, a feedforward control strategy is proposed. In addition, the design principle for the current and voltage regulators are discussed. Simulation and experimental results are provided......In this paper, the disturbance rejection performance of the cascaded control strategy for UPS system is investigated. The comparison of closed loop system performance between conventional cascaded control (CCC) strategy and state-decoupling cascaded control (SDCC) strategy are further explored...

  20. A soil-canopy scheme for use in a numerical model of the atmosphere: 1D stand-alone model

    Science.gov (United States)

    Kowalczyk, E. A.; Garratt, J. R.; Krummel, P. B.

    We provide a detailed description of a soil-canopy scheme for use in the CSIRO general circulation models (GCMs) (CSIRO-4 and CSIRO-9), in the form of a one-dimensional stand-alone model. In addition, the paper documents the model's ability to simulate realistic surface fluxes by comparison with mesoscale model simulations (involving more sophisticated soil and boundary-layer treatments) and observations, and the diurnal range in surface quantities, including extreme maximum surface temperatures. The sensitivity of the model to values of the surface resistance is also quantified. The model represents phase 1 of a longer-term plan to improve the atmospheric boundary layer (ABL) and surface schemes in the CSIRO GCMs.

  1. Assessing Self-Regulation of Learning Dimensions in a Stand-alone MOOC Platform

    Directory of Open Access Journals (Sweden)

    Daniel Friday Owoichoche Onah

    2017-06-01

    Full Text Available A capacity for self-regulated learning (SRL has long been recognised as an important factor in successful studies. Although educational researchers have started to investigate the concept of SRL in the context of online education, very little is yet known about SRL in relation to massive open online courses (MOOCs or of appropriate strategies to foster SRL skills in MOOC learners. Self-regulation is particularly important in a MOOC-based study, which demands effective independent learning, and where widely acknowledged high dropout rates are observed. This study reports an investigation and assessment of the concept of SRL using a novel MOOC platform (eLDa by providing study options (either via a self-directed learning or instructor-led learning using a novel learning tool. In view of this, the research presents general description of self-regulated learning and explored the various existing dimensions used to expose the learners SRL skills. Drawing comparison of the online tool, the results and findings of the data were analysed. The study dis¬cusses how the various dimensions contributed to the knowledge representation of the self-regulated learning abilities shown by the learners. We present how these SRL dimensions captured using the measuring instrument contributes to our growing understanding of the distinctive features of the individual learner’s self-regulated learning. MOOCs success required a high performance of self-regulated learning abilities which at the moment very little has shown these degree of supporting SRL skills. This paper presents preliminary evaluation of a novel e-learning tool known, as ‘eLDa’ developed to implement this investi¬gation of self-regulation of learning. The research applied a modified online self-regulated learning questionnaire (OSLQ as the instrument to measure the SRL skills. The modified questionnaire known as MOOC OSLQ (MOSLQ was developed with a 19-item scale questions that exposes the six

  2. Wind-driven stand-alone DFIG with battery and pumped hydro ...

    Indian Academy of Sciences (India)

    Renewable energy electric conversion system; induction generators; wind power generation; energy storage; power converters. ... converter, (ii) wide speed operation of wind-driven DFIG, (iii) reduced battery capacity, (iv) high energy storage using PHSP and (v) availability of continuous power to the isolated loads.

  3. Alignment of the CMS Silicon Strip Tracker during stand-alone Commissioning

    CERN Document Server

    Adam, W.; Dragicevic, M.; Friedl, M.; Fruhwirth, R.; Hansel, S.; Hrubec, J.; Krammer, M.; Oberegger, M.; Pernicka, M.; Schmid, S.; Stark, R.; Steininger, H.; Uhl, D.; Waltenberger, W.; Widl, E.; Van Mechelen, P.; Cardaci, M.; Beaumont, W.; de Langhe, E.; de Wolf, E.A.; Delmeire, E.; Hashemi, M.; Bouhali, O.; Charaf, O.; Clerbaux, B.; Dewulf, J.-P.; Elgammal, S.; Hammad, G.; de Lentdecker, G.; Marage, P.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Adler, V.; Devroede, O.; De Weirdt, S.; D'Hondt, J.; Goorens, R.; Heyninck, J.; Maes, J.; Mozer, Matthias Ulrich; Tavernier, S.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Bonnet, J.-L.; Bruno, G.; De Callatay, B.; Florins, B.; Giammanco, A.; Gregoire, G.; Keutgen, Th.; Kcira, D.; Lemaitre, V.; Michotte, D.; Militaru, O.; Piotrzkowski, K.; Quertermont, L.; Roberfroid, V.; Rouby, X.; Teyssier, D.; daubie, E.; Anttila, E.; Czellar, S.; Engstrom, P.; Harkonen, J.; Karimaki, V.; Kostesmaa, J.; Kuronen, A.; Lampen, T.; Linden, T.; Luukka, P.-R.; Maenaa, T.; Michal, S.; Tuominen, E.; Tuominiemi, J.; Ageron, M.; Baulieu, G.; Bonnevaux, A.; Boudoul, G.; Chabanat, E.; Chabert, E.; Chierici, R.; Contardo, D.; Della Negra, R.; Dupasquier, T.; Gelin, G.; Giraud, N.; Guillot, G.; Estre, N.; Haroutunian, R.; Lumb, N.; Perries, S.; Schirra, F.; Trocme, B.; Vanzetto, S.; Agram, J.-L.; Blaes, R.; Drouhin, F.; Ernenwein, J.-P.; Fontaine, J.-C.; Berst, J.-D.; Brom, J.-M.; Didierjean, F.; Goerlach, U.; Graehling, P.; Gross, L.; Hosselet, J.; Juillot, P.; Lounis, A.; Maazouzi, C.; Olivetto, C.; Strub, R.; Van Hove, P.; Anagnostou, G.; Brauer, R.; Esser, H.; Feld, L.; Karpinski, W.; Klein, K.; Kukulies, C.; Olzem, J.; Ostapchuk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schwering, G.; Sprenger, D.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Beissel, F.; Bock, E.; Flugge, G.; Gillissen, C.; Hermanns, T.; Heydhausen, D.; Jahn, D.; Kaussen, G.; Linn, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Stahl, A.; Zoeller, M.H.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R.; Hauk, J.; Klanner, R.; Pein, U.; Schleper, P.; Steinbruck, G.; Blum, P.; De Boer, W.; Dierlamm, A.; Dirkes, G.; Fahrer, M.; Frey, M.; Furgeri, A.; Hartmann, F.; Heier, S.; Hoffmann, K.-H.; Kaminski, J.; Ledermann, B.; Liamsuwan, T.; Muller, S.; Muller, Th.; Schilling, F.-P.; Simonis, H.-J.; Steck, P.; Zhukov, V.; Cariola, P.; De Robertis, G.; Ferorelli, R.; Fiore, L.; Preda, M.; Sala, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Creanza, D.; De Filippis, N.; De Palma, M.; Giordano, D.; Maggi, G.; Manna, N.; My, S.; Selvaggi, G.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M.A.; Sparti, V.; Sutera, C.; Tricomi, A.; Tuve, C.; Brianzi, M.; Civinini, C.; Maletta, F.; Manolescu, F.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Broccolo, B.; Ciulli, V.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Magini, N.; Parrini, G.; Scarlini, E.; Cerati, G.; Azzi, P.; Bacchetta, N.; Candelori, A.; Dorigo, T.; Kaminsky, A.; Karaevski, S.; Khomenkov, V.; Reznikov, S.; Tessaro, M.; Bisello, D.; De Mattia, M.; Giubilato, P.; Loreti, M.; Mattiazzo, S.; Nigro, M.; Paccagnella, A.; Pantano, D.; Pozzobon, N.; Tosi, M.; Bilei, G.M.; Checcucci, B.; Fano, L.; Servoli, L.; Ambroglini, F.; Babucci, E.; Benedetti, D.; Biasini, M.; Caponeri, B.; Covarelli, R.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Marcantonini, M.; Postolache, V.; Santocchia, A.; Spiga, D.; Bagliesi, G.; Balestri, G.; Berretta, L.; Bianucci, S.; Boccali, T.; Bosi, F.; Bracci, F.; Castaldi, R.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A.S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Lomtadze, T.; Lungu, G.A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Sentenac, D.; Serban, A.T.; Slav, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tolaini, S.; Venturi, A.; Verdini, P.G.; Vos, M.; Zaccarelli, L.; Avanzini, C.; Basti, A.; Benucci, L.; Bocci, A.; Cazzola, U.; Fiori, F.; Linari, S.; Massa, M.; Messineo, A.; Segneri, G.; Tonelli, G.; Azzurri, P.; Bernardini, J.; Borrello, L.; Calzolari, F.; Foa, L.; Gennai, S.; Ligabue, F.; Petrucciani, G.; Rizzi, A.; Yang, Z.; Benotto, F.; Demaria, N.; Dumitrache, F.; Farano, R.; Borgia, M.A.; Castello, R.; Costa, M.; Migliore, E.; Romero, A.; Abbaneo, D.; Abbas, M.; Ahmed, I.; Akhtar, I.; Albert, E.; Bloch, C.; Breuker, H.; Butt, S.; Buchmuller, O.; Cattai, A.; Delaere, C.; Delattre, M.; Edera, L.M.; Engstrom, P.; Eppard, M.; Gateau, M.; Gill, K.; Giolo-Nicollerat, A.-S.; Grabit, R.; Honma, A.; Huhtinen, M.; Kloukinas, K.; Kortesmaa, J.; Kottelat, L.J.; Kuronen, A.; Leonardo, N.; Ljuslin, C.; Mannelli, M.; Masetti, L.; Marchioro, A.; Mersi, S.; Michal, S.; Mirabito, L.; Muffat-Joly, J.; Onnela, A.; Paillard, C.; Pal, I.; Pernot, J.F.; Petagna, P.; Petit, P.; Piccut, C.; Pioppi, M.; Postema, H.; Ranieri, R.; Ricci, D.; Rolandi, G.; Ronga, F.; Sigaud, C.; Syed, A.; Siegrist, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vander Donckt, M.; Vasey, F.; Alagoz, E.; Amsler, Claude; Chiochia, V.; Regenfus, Christian; Robmann, P.; Rochet, J.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Wilke, L.; Church, I.; Cole, J.; Coughlan, J.; Gay, A.; Taghavi, S.; Tomalin, I.; Bainbridge, R.; Cripps, N.; Fulcher, J.; Hall, G.; Noy, M.; Pesaresi, M.; Radicci, V.; Raymond, D.M.; Sharp, P.; Stoye, M.; Wingham, M.; Zorba, O.; Goitom, I.; Hobson, P.R.; Reid, I.; Teodorescu, L.; Hanson, G.; Jeng, G.-Y.; Liu, H.; Pasztor, G.; Satpathy, A.; Stringer, R.; Mangano, B.; Affolder, K.; Affolder, T.; Allen, A.; Barge, D.; Burke, S.; Callahan, D.; Campagnari, C.; Crook, A.; D'Alfonso, M.; Dietch, J.; Garberson, Jeffrey Ford; Hale, D.; Incandela, H.; Incandela, J.; Jaditz, S.; Kalavase, P.; Kreyer, S.; Kyre, S.; Lamb, J.; Mc Guinnessr, C.; Mills, C.; Nguyen, H.; Nikolic, M.; Lowette, S.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rubinstein, N.; Sanhueza, S.; Shah, Y.; Simms, L.; Staszak, D.; Stoner, J.; Stuart, D.; Swain, S.; Vlimant, J.-R.; White, D.; Ulmer, K.A.; Wagner, S.R.; Bagby, L.; Bhat, P.C.; Burkett, K.; Cihangir, S.; Gutsche, O.; Jensen, H.; Johnson, M.; Luzhetskiy, N.; Mason, D.; Miao, T.; Moccia, S.; Noeding, C.; Ronzhin, A.; Skup, E.; Spalding, W.J.; Spiegel, L.; Tkaczyk, S.; Yumiceva, F.; Zatserklyaniy, A.; Zerev, E.; Anghel, I.; Bazterra, V.E.; Gerber, C.E.; Khalatian, S.; Shabalina, E.; Baringer, Philip S.; Bean, A.; Chen, J.; Hinchey, C.; Martin, C.; Moulik, T.; Robinson, R.; Gritsan, A.V.; Lae, C.K.; Tran, N.V.; Everaerts, P.; Hahn, K.A.; Harris, P.; Nahn, S.; Rudolph, M.; Sung, K.; Betchart, B.; Demina, R.; Gotra, Y.; Korjenevski, S.; Miner, D.; Orbaker, D.; Christofek, L.; Hooper, R.; Landsberg, G.; Nguyen, D.; Narain, M.; Speer, T.; Tsang, K.V.

    2009-01-01

    The results of the CMS tracker alignment analysis are presented using the data from cosmic tracks, optical survey information, and the laser alignment system at the Tracker Integration Facility at CERN. During several months of operation in the spring and summer of 2007, about five million cosmic track events were collected with a partially active CMS Tracker. This allowed us to perform first alignment of the active silicon modules with the cosmic tracks using three different statistical approaches; validate the survey and laser alignment system performance; and test the stability of Tracker structures under various stresses and temperatures ranging from +15C to -15C. Comparison with simulation shows that the achieved alignment precision in the barrel part of the tracker leads to residual distributions similar to those obtained with a random misalignment of 50 (80) microns in the outer (inner) part of the barrel.

  4. Experimental stand-alone self-excited induction generator driven by a diesel motor

    Directory of Open Access Journals (Sweden)

    Mhamdi Taoufik

    2017-12-01

    Full Text Available This paper presents an experimental work to design and size a diesel generator (DG. The basic system is equipped with a 1.5 kW self-excited induction generator (SEIG, a diesel motor (DM, a static voltage compensator (SVC and controllers. A proportional integral controller is used to meet the requirement of the SEIG frequency regulation. A controlled voltage source is performed by using an SVC with a fuzzy controller, which adjusts voltage by varying the amount of the injected reactive power. An experimental set-up is used to identify the SEIG parameters and select the convenient bank of capacitors that minimize the SEIG starting up time and fix the convenient margin of voltage. The system has been tested by simulation using models implemented by Matlab/Simulink software. The simulation results confirm the efficiency of the proposed strategy of voltage regulation. Keywords: Diesel motor, SEIG, SVC, Voltage regulation, Frequency regulation

  5. A case study of a typical 2.32 kW{sub P} stand-alone photovoltaic (SAPV) in composite climate of New Delhi (India)

    Energy Technology Data Exchange (ETDEWEB)

    Chel, Arvind; Tiwari, G.N. [Center for Energy Studies (CES), Indian Institute of Technology, Hauz Khas, New Delhi 110 016 (India)

    2011-04-15

    This paper presents rigorous experimental outdoor performance of a 2.32 kW{sub P} stand-alone photovoltaic (SAPV) system in New Delhi (India) for four weather types in each month such as clear, hazy, partially cloudy/foggy and fully cloudy/foggy weather conditions respectively. The daily power generated from the existing SAPV system was experimentally found in the range of 4-6 kW h/day depending on the prevailing sky conditions. The number of days and daily power generated corresponding to four weather types in each month were used to determine monthly and subsequently annual power generation from the existing SAPV system. There are three daily load profiles with and without earth to air heat exchanger suitable for three seasons like summer (3.75-6.15 kW h/day), winter (2.79-5.19 kW h/day) and rainy (3.75 kW h/day). The hourly efficiency of the SAPV system components are determined and presented in this paper. The life cycle cost (LCC) analysis for the existing typical SAPV system is carried out to determine unit cost of electricity. The effect of annual degradation rate of PV system efficiency is also presented in this paper. The energy production factor (EPF) and the energy payback time (EPBT) of the SAPV system was also determined and presented in this paper. (author)

  6. An ArcGIS analysis of Stand-alone GPS quality for Road Pricing

    DEFF Research Database (Denmark)

    Zabic, Martina

    2006-01-01

    The paper presents the methods and some of the result maps from a study of GPS quality in relation to road pricing in a dense urban area. Data from 500 cars were colleted over a two-year period in the Copenhagen region (Denmark). The data was analyzed in ArcGIS in order to determine whether the GPS...... quality and reliability is adequate for implementation of a road pricing system. The GPS log files was imported into ArcGIS and analyzed in relation to the digital road network and the density of the high rise areas in order to examine where the high buildings and narrow street canyons causes too many...

  7. Development of Stand Alone Application Tool for Processing and Quality Measurement of Weld Imperfection Image Captured by μ-Focused Digital Radiography Using MATLAB- Based Graphical User Interface

    Directory of Open Access Journals (Sweden)

    PZ Nadila

    2012-12-01

    Full Text Available Digital radiography incresingly is being applied in the fabrication industry. Compared to film- based radiography, digitally radiographed images can be acquired with less time and fewer exposures. However, noises can simply occur on the digital image resulting in a low-quality result. Due to this and the system’s complexity, parameters’ sensitivity, and environmental effects, the results can be difficult to interpret, even for a radiographer. Therefore, the need of an application tool to improve and evaluate the image is becoming urgent. In this research, a user-friendly tool for image processing and image quality measurement was developed. The resulting tool contains important components needed by radiograph inspectors in analyzing defects and recording the results. This tool was written by using image processing and the graphical user interface development environment and compiler (GUIDE toolbox available in Matrix Laboratory (MATLAB R2008a. In image processing methods, contrast adjustment, and noise removal, edge detection was applied. In image quality measurement methods, mean square error (MSE, peak signal-to-noise ratio (PSNR, modulation transfer function (MTF, normalized signal-to-noise ratio (SNRnorm, sensitivity and unsharpness were used to measure the image quality. The graphical user interface (GUI wass then compiled to build a Windows, stand-alone application that enables this tool to be executed independently without the installation of MATLAB.

  8. Stand-alone photovoltaic (PV) integrated with earth to air heat exchanger (EAHE) for space heating/cooling of adobe house in New Delhi (India)

    International Nuclear Information System (INIS)

    Chel, Arvind; Tiwari, G.N.

    2010-01-01

    This paper deals with an experimental outdoor annual performance evaluation of 2.32 kW P photovoltaic (PV) power system located at solar energy park in New Delhi composite climatic conditions. This PV system operates the daily electrical load nearly 10 kW h/day which comprises of various applications such as electric air blower of an earth to air heat exchanger (EAHE) used for heating/cooling of adobe house, ceiling fan, fluorescent tube-light, computer, submersible water pump, etc. The outdoor efficiencies, power generated and lost in PV system components were determined using hourly experimental measured data for 1 year on typical clear day in each month. These realistic data are useful for design engineers for outdoor assessment of PV system components. The energy conservation, mitigation of CO 2 emission and carbon credit potential of the existing PV integrated EAHE system is presented in this paper. Also, the energy payback time (EPBT) and unit cost of electricity were determined for both stand-alone PV (SAPV) and building roof integrated PV (BIPV) systems.

  9. Fuzzy Secondary Controller for Autonomous Stand-alone and Grid-connected AC Microgrid

    DEFF Research Database (Denmark)

    Neves, Rodolpho V. A.; Machado, Ricardo Q.; Oliveira, Vilma A.

    2016-01-01

    The present paper adresses the AC microgrid control issue using the hierarchical control structure and droop controllers for load sharing. Once the droop controllers impose an operation with frequency and voltage deviations, depending on the load and droop parameters, a hierarchical control...... structure must be added to change the droop controller operating points. The hierarchical controllers operate with local measurements and shared signals from communication links among the distributed generation systems connected to the microgrid. Depending on the geographical size of the microgrid......, the communication links can be economically unviable. This paper thus proposes a fuzzy secondary controller for AC microgrids to reduce the link communication dependency by using only local measurements. The simulation results show that the deviations as happened with the conventional secondary controllers can...

  10. X-ray microbeam stand-alone facility for cultured cells irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Sebastian, E-mail: sebastian.bozek@yahoo.com [Jagiellonian University Medical College, Department of Pharmaceutical Biophysics, Krakow (Poland); Bielecki, Jakub; Wiecheć, Anna; Lekki, Janusz; Stachura, Zbigniew; Pogoda, Katarzyna; Lipiec, Ewelina; Tkocz, Konrad; Kwiatek, Wojciech M. [Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow (Poland)

    2017-03-01

    Highlights: • An X-ray microbeam line for irradiation of living cultured cells was constructed. • A step by step explanation of working principles with engineering details, procedures and calculations is presented. • A model of beam and cell interaction is presented. • A method of uniform irradiation of living cells with an exact dose per a cell is presented. • Results of preliminary experiments are presented. - Abstract: The article describes an X-ray microbeam standalone facility dedicated for irradiation of living cultured cells. The article can serve as an advice for such facilities construction, as it begins from engineering details, through mathematical modeling and experimental procedures, ending up with preliminary experimental results and conclusions. The presented system consists of an open type X-ray tube with microfocusing down to about 2 μm, an X-ray focusing system with optical elements arranged in the nested Kirckpatrick-Baez (or Montel) geometry, a sample stand and an optical microscope with a scientific digital CCD camera. For the beam visualisation an X-ray sensitive CCD camera and a spectral detector are used, as well as a scintillator screen combined with the microscope. A method of precise one by one irradiation of previously chosen cells is presented, as well as a fast method of uniform irradiation of a chosen sample area. Mathematical models of beam and cell with calculations of kerma and dose are presented. The experiments on dose-effect relationship, kinetics of DNA double strand breaks repair, as well as micronuclei observation were performed on PC-3 (Prostate Cancer) cultured cells. The cells were seeded and irradiated on Mylar foil, which covered a hole drilled in the Petri dish. DNA lesions were visualised with γ-H2AX marker combined with Alexa Fluor 488 fluorescent dye.

  11. APT - NASA ENHANCED VERSION OF AUTOMATICALLY PROGRAMMED TOOL SOFTWARE - STAND-ALONE VERSION

    Science.gov (United States)

    Premo, D. A.

    1994-01-01

    The APT code is one of the most widely used software tools for complex numerically controlled (N/C) machining. APT is an acronym for Automatically Programmed Tools and is used to denote both a language and the computer software that processes that language. Development of the APT language and software system was begun over twenty years ago as a U. S. government sponsored industry and university research effort. APT is a "problem oriented" language that was developed for the explicit purpose of aiding the N/C machine tools. Machine-tool instructions and geometry definitions are written in the APT language to constitute a "part program." The APT part program is processed by the APT software to produce a cutter location (CL) file. This CL file may then be processed by user supplied post processors to convert the CL data into a form suitable for a particular N/C machine tool. This June, 1989 offering of the APT system represents an adaptation, with enhancements, of the public domain version of APT IV/SSX8 to the DEC VAX-11/780 for use by the Engineering Services Division of the NASA Goddard Space Flight Center. Enhancements include the super pocket feature which allows concave and convex polygon shapes of up to 40 points including shapes that overlap, that leave islands of material within the pocket, and that have one or more arcs as part of the pocket boundary. Recent modifications to APT include a rework of the POCKET subroutine and correction of an error that prevented the use within a macro of a macro variable cutter move statement combined with macro variable double check surfaces. Former modifications included the expansion of array and buffer sizes to accommodate larger part programs, and the insertion of a few user friendly error messages. The APT system software on the DEC VAX-11/780 is organized into two separate programs: the load complex and the APT processor. The load complex handles the table initiation phase and is usually only run when changes to the

  12. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Science.gov (United States)

    Daudin, L.; Barberet, Ph.; Serani, L.; Moretto, Ph.

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d'Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA's nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  13. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Energy Technology Data Exchange (ETDEWEB)

    Daudin, L., E-mail: daudin@cenbg.in2p3.fr [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Barberet, Ph.; Serani, L.; Moretto, Ph. [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA’s nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  14. Leadership in Dental Hygiene Degree Completion Programs: A Pilot Study Comparing Stand-Alone Leadership Courses and Leadership-Infused Curricula.

    Science.gov (United States)

    Smith, Michelle L; Gurenlian, JoAnn R; Freudenthal, Jacqueline J; Farnsworth, Tracy J

    2016-05-01

    The aim of this study was to define the extent to which leadership and leadership skills are taught in dental hygiene degree completion programs by comparing stand-alone leadership courses/hybrid programs with programs that infuse leadership skills throughout the curricula. The study involved a mixed-methods approach using qualitative and quantitative data. Semi-structured interviews were conducted with program directors and faculty members who teach a stand-alone leadership course, a hybrid program, or leadership-infused courses in these programs. A quantitative comparison of course syllabi determined differences in the extent of leadership content and experiences between stand-alone leadership courses and leadership-infused curricula. Of the 53 U.S. dental hygiene programs that offer degree completion programs, 49 met the inclusion criteria, and 19 programs provided course syllabi. Of the program directors and faculty members who teach a stand-alone leadership course or leadership-infused curriculum, 16 participated in the interview portion of the study. The results suggested that competencies related to leadership were not clearly defined or measurable in current teaching. Reported barriers to incorporating a stand-alone leadership course included overcrowded curricula, limited qualified faculty, and lack of resources. The findings of this study provide a synopsis of leadership content and gaps in leadership education for degree completion programs. Suggested changes included defining a need for leadership competencies and providing additional resources to educators such as courses provided by the American Dental Education Association and the American Dental Hygienists' Association.

  15. Direct Flux Control for Stand-Alone Operation Brushless Doubly Fed Induction Generators Using a Resonant-Based Sliding-Mode Control Approach

    Directory of Open Access Journals (Sweden)

    Kai Ji

    2018-04-01

    Full Text Available In this paper, a novel voltage control strategy for stand-alone operation brushless doubly fed induction generators for variable speed constant frequency wind energy conversion systems was presented and discussed. Based on the model of the power generation system, the proposed direct flux control strategy employs a nonlinear reduced-order generalized integrator-based resonant sliding-mode control approach to directly calculate and regulate the output value of converter which the control winding stator requires so as to eliminate its instantaneous errors, without involving any synchronous rotating coordinate transformations. The stability, robustness and convergence capability of the proposed control strategy were described and analyzed. Owing to the fact no additional current control inner loops are involved, the system configuration is therefore simplified and the dynamic performance enhanced. A constant converter switching frequency was achieved by using space vector pulse width modulation, which reduces the harmonics of the generator terminal voltage. In addition, the feasibility and validity of the proposed scheme is verified by experiments, and excellent steady and transient performance is achieved.

  16. Epicardial, Biatrial Ablation With Integrated Uni-bipolar Radiofrequency Technology in Stand-alone Persistent Atrial Fibrillation.

    Science.gov (United States)

    Rosati, Fabrizio; Muneretto, Claudio; Merati, Elisa; Polvani, Gianluca; Moltrasio, Massimo; Tondo, Claudio; Curnis, Antonio; Cerini, Manuel; Metras, Alexandre; Bisleri, Gianluigi

    Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm. Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation. Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve

  17. The Research on Second-Order ADRC Algorithm of Using Wind Turbine Virtual Inertia to Participate in Primary Frequency Regulation in a Small Stand-Alone Microgrid

    Directory of Open Access Journals (Sweden)

    Wang Yi

    2018-01-01

    Full Text Available In order to improve the transient stability of frequency in a small stand-alone microgrid (SSM, this paper takes a SSM composed of a direct-drive permanent magnet synchronous generator (D-PMSG and a micro gas turbine (MGT as the background and uses wind turbine generator (WTG virtual inertia (VI to participate in the primary (short-term system frequency regulation. First of all, this paper constructs a grid-connected model composed of a WTG and a MGT, analyzes the WTG virtual inertia frequency regulation mechanism, and explains the principle of proportional-differentiation (PD virtual inertia control (VIC and its shortcomings. Secondly, the paper introduces the structure principle of n-order active disturbance rejection control (ADRC and deduces the design process of second-order ADRC-VIC. Finally, through the simulation and experimental verification, comparing the frequency perturbation of without-VIC, PD-VIC, and ADRC-VIC, it is concluded that PD-VIC and ADRC-VIC both can use the WTG virtual inertia to participate in the primary frequency regulation. The frequency regulation effect of ADRC-VIC is better than PD-VIC, ADRC-VIC can extend the rotor speed recovery time and avoid overshoot, and its frequency fluctuation amplitude and settling time are obviously improved, and ADRC-VIC can effectively avoid the overshoot phenomenon of the MGT output power.

  18. Development of a Laser-Powered Dielectric Structure-Based Accelerator as a Stand-Alone Particle Source

    International Nuclear Information System (INIS)

    Yoder, R. B.; Travish, G.; Arab, E. R.; Fong, D.; Hoyer, Z.; Lacroix, U. H.; Vartanian, N.; Rosenzweig, J. B.

    2010-01-01

    An experimental program to develop and build a dielectric-based slab-symmetric structure (the micro-accelerator platform, or MAP) for generating and accelerating low-energy electrons is underway at UCLA and Manhattanville College. This optical acceleration structure is effectively a resonant cavity powered by a side-coupled laser, and has applications as a radiation source for medicine or industry. We present recent experimental and computational results on the accelerator, and progress toward its incorporation into a self-contained particle source. Such a particle source would incorporate a micron-scale electron emitter and a non-relativistic capture region to enable self-injection into the synchronous field within the accelerator. A prototype of the accelerator itself has been constructed from candidate dielectric materials using micromanufacturing techniques; the current status of the testing program is described. A novel electron emitter incorporating pyroelectric crystals with field-enhancing tips has been demonstrated to produce steady currents; the results are dependent on tip geometry, and appear suitable for injection into a microstructure. Extension of the MAP concept to non-relativistic velocities, as in the stand-alone source, requires a tapered structure that gives rise to numerous complications including beam defocusing and manufacturing challenges; approaches for addressing these complications are mentioned.

  19. Search Improvement Process-Chaotic Optimization-Particle Swarm Optimization-Elite Retention Strategy and Improved Combined Cooling-Heating-Power Strategy Based Two-Time Scale Multi-Objective Optimization Model for Stand-Alone Microgrid Operation

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2017-11-01

    Full Text Available The optimal dispatching model for a stand-alone microgrid (MG is of great importance to its operation reliability and economy. This paper aims at addressing the difficulties in improving the operational economy and maintaining the power balance under uncertain load demand and renewable generation, which could be even worse in such abnormal conditions as storms or abnormally low or high temperatures. A new two-time scale multi-objective optimization model, including day-ahead cursory scheduling and real-time scheduling for finer adjustments, is proposed to optimize the operational cost, load shedding compensation and environmental benefit of stand-alone MG through controllable load (CL and multi-distributed generations (DGs. The main novelty of the proposed model is that the synergetic response of CL and energy storage system (ESS in real-time scheduling offset the operation uncertainty quickly. And the improved dispatch strategy for combined cooling-heating-power (CCHP enhanced the system economy while the comfort is guaranteed. An improved algorithm, Search Improvement Process-Chaotic Optimization-Particle Swarm Optimization-Elite Retention Strategy (SIP-CO-PSO-ERS algorithm with strong searching capability and fast convergence speed, was presented to deal with the problem brought by the increased errors between actual renewable generation and load and prior predictions. Four typical scenarios are designed according to the combinations of day types (work day or weekend and weather categories (sunny or rainy to verify the performance of the presented dispatch strategy. The simulation results show that the proposed two-time scale model and SIP-CO-PSO-ERS algorithm exhibit better performance in adaptability, convergence speed and search ability than conventional methods for the stand-alone MG’s operation.

  20. An automatic time domain reflectometry device to measure and store soil water contents for stand-alone field use

    NARCIS (Netherlands)

    Elsen, van den H.G.M.; Kokot, J.; Skierucha, W.; Halbertsma, J.M.

    1995-01-01

    A field set-up was developed to measure soil moisture content on ten different positions using the time domain reflectometry (TDR) technique. The set-up works on a 12 V battery or solar panel system, independent of an external power source, has low power consumption, and compact dimensions. The

  1. Post-processing in cardiovascular computed tomography. Performance of a client server solution versus a stand-alone solution

    International Nuclear Information System (INIS)

    Luecke, C.; Foldyna, B.; Andres, C.; Grothoff, M.; Nitzsche, S.; Gutberlet, M.; Lehmkuhl, L.; Boehmer-Lasthaus, S.

    2014-01-01

    Purpose: To compare the performance of server-based (CSS) versus stand-alone post-processing software (ES) for the evaluation of cardiovascular CT examinations (cvCT) and to determine the crucial steps. Data of 40 patients (20 patients for coronary artery evaluation and 20 patients prior to transcatheter aortic valve implantation [TAVI]) were evaluated by 5 radiologists with CSS and ES. Data acquisition was performed using a dual-source 128-row CT unit (SOMATOM Definition Flash, Siemens, Erlangen, Germany) and a 64-row CT unit (Brilliance 64, Philips, Hamburg, Germany). The following workflow was evaluated: Data loading, aorta and coronary segmentation, curved multiplanar reconstruction (cMPR) and 3 D volume rendering technique (3D-VRT), measuring of coronary artery stenosis and planimetry of the aortic annulus. The time requirement and subjective quality for the workflow were evaluated. The coronary arteries as well as the TAVI data could be evaluated significantly faster with CSS (5.5 ± 2.9 min and 8.2 ± 4.0 min, respectively) than with ES (13.9 ± 5.2 min and 15.2 ± 10.9 min, respectively, p = 0.01). Segmentation of the aorta (CSS: 1.9 ± 2.0 min, ES: 3.7 ± 3.3 min), generating cMPR of coronaries (CSS: 0.5 ± 0.2 min, ES: 5.1 ± 2.6 min), aorta and iliac vessels (CSS: 0.5 ± 0.4 min and 0.4 ± 0.4 min, respectively, ES: 1.6 ± 0.7 min and 2.8 ± 3 min, respectively) could be performed significantly faster with CSS than with ES with higher quality of cMPR, measuring of coronary stenosis and 3D-VRT (p < 0.05). Evaluation of cvCT can be accomplished significantly faster and better with CSS than with ES. The segmentation remains the most time-consuming workflow step, so optimization of segmentation algorithms could improve performance even further.

  2. CANGS DB: a stand-alone web-based database tool for processing, managing and analyzing 454 data in biodiversity studies

    Directory of Open Access Journals (Sweden)

    Schlötterer Christian

    2011-06-01

    Full Text Available Abstract Background Next generation sequencing (NGS is widely used in metagenomic and transcriptomic analyses in biodiversity. The ease of data generation provided by NGS platforms has allowed researchers to perform these analyses on their particular study systems. In particular the 454 platform has become the preferred choice for PCR amplicon based biodiversity surveys because it generates the longest sequence reads. Nevertheless, the handling and organization of massive amounts of sequencing data poses a major problem for the research community, particularly when multiple researchers are involved in data acquisition and analysis. An integrated and user-friendly tool, which performs quality control, read trimming, PCR primer removal, and data organization is desperately needed, therefore, to make data interpretation fast and manageable. Findings We developed CANGS DB (Cleaning and Analyzing Next Generation Sequences DataBase a flexible, stand alone and user-friendly integrated database tool. CANGS DB is specifically designed to organize and manage the massive amount of sequencing data arising from various NGS projects. CANGS DB also provides an intuitive user interface for sequence trimming and quality control, taxonomy analysis and rarefaction analysis. Our database tool can be easily adapted to handle multiple sequencing projects in parallel with different sample information, amplicon sizes, primer sequences, and quality thresholds, which makes this software especially useful for non-bioinformaticians. Furthermore, CANGS DB is especially suited for projects where multiple users need to access the data. CANGS DB is available at http://code.google.com/p/cangsdb/. Conclusion CANGS DB provides a simple and user-friendly solution to process, store and analyze 454 sequencing data. Being a local database that is accessible through a user-friendly interface, CANGS DB provides the perfect tool for collaborative amplicon based biodiversity surveys

  3. Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysis

    Directory of Open Access Journals (Sweden)

    Hsieh Pang-Hsing

    2008-06-01

    Full Text Available Abstract Background Initial promise of a stand-alone interbody fusion cage to treat chronic back pain and restore disc height has not been realized. In some instances, a posterior spinal fixation has been used to enhance stability and increase fusion rate. In this manuscript, a new stand-alone cage is compared with conventional fixation methods based on the finite element analysis, with a focus on investigating cage-bone interface mechanics and stress distribution on the adjacent tissues. Methods Three trapezoid 8° interbody fusion cage models (dual paralleled cages, a single large cage, or a two-part cage consisting of a trapezoid box and threaded cylinder were created with or without pedicle screws fixation to investigate the relative importance of the screws on the spinal segmental response. The contact stress on the facet joint, slip displacement of the cage on the endplate, and rotational angle of the upper vertebra were measured under different loading conditions. Results Simulation results demonstrated less facet stress and slip displacement with the maximal contact on the cage-bone interface. A stand-alone two-part cage had good slip behavior under compression, flexion, extension, lateral bending and torsion, as compared with the other two interbody cages, even with the additional posterior fixation. However, the two-part cage had the lowest rotational angles under flexion and torsion, but had no differences under extension and lateral bending. Conclusion The biomechanical benefit of a stand-alone two-part fusion cage can be justified. This device provided the stability required for interbody fusion, which supports clinical trials of the cage as an alternative to circumferential fixations.

  4. Feasibility Study and Optimization of An Hybrid System (Eolian ...

    African Journals Online (AJOL)

    Feasibility Study and Optimization of An Hybrid System (Eolian- Photovoltaic - Diesel) With Provision of Electric Energy Completely Independent. ... reducing emissions of greenhouse gas (CO2 rate = 16086 kg / year for a system using only the generator diesel and is 599 kg / year for the stand alone hybrid system studied).

  5. Optimizing the solar array of stand-alone photovoltaic energy systems as a function of time and load profiles

    Science.gov (United States)

    Abou-Hussein, M. S.; El-Maghraby, M. H.; Groumpos, P. P.; El-Geldawy, F. A.; El-Tamaly, H. H.

    This paper presents a proposed novel technique in which an accurate optimum design of the solar array (SCA) can be attained. It depends on an hour-by-hour approach with different daily load profiles. A generalized mathematical formula has been developed for sizing of the solar array given the geographical and one year's insolation data for a particular site in Egypt. This approach can reduce the required size compared to other methods using the same tilt angle.

  6. Study of a thermoelectric system equipped with a maximum power point tracker for stand-alone electric generation.

    Science.gov (United States)

    Favarel, C.; Champier, D.; Bédécarrats, J. P.; Kousksou, T.; Strub, F.

    2012-06-01

    According to the International Energy Agency, 1.4 billion people are without electricity in the poorest countries and 2.5 billion people rely on biomass to meet their energy needs for cooking in developing countries. The use of cooking stoves equipped with small thermoelectric generator to provide electricity for basic needs (LED, cell phone and radio charging device) is probably a solution for houses far from the power grid. The cost of connecting every house with a landline is a lot higher than dropping thermoelectric generator in each house. Thermoelectric generators have very low efficiency but for isolated houses, they might become really competitive. Our laboratory works in collaboration with plane`te-bois (a non governmental organization) which has developed energy-efficient multifunction (cooking and hot water) stoves based on traditional stoves designs. A prototype of a thermoelectric generator (Bismuth Telluride) has been designed to convert a small part of the energy heating the sanitary water into electricity. This generator can produce up to 10 watts on an adapted load. Storing this energy in a battery is necessary as the cooking stove only works a few hours each day. As the working point of the stove varies a lot during the use it is also necessary to regulate the electrical power. An electric DC DC converter has been developed with a maximum power point tracker (MPPT) in order to have a good efficiency of the electronic part of the thermoelectric generator. The theoretical efficiency of the MMPT converter is discussed. First results obtained with a hot gas generator simulating the exhaust of the combustion chamber of a cooking stove are presented in the paper.

  7. FEASIBILITY STUDY AND OPTIMIZATION OF AN HYBRID SYSTEM (EOLIAN- PHOTOVOLTAIC - DIESEL WITH PROVISION OF ELECTRIC ENERGY COMPLETELY INDEPENDENT

    Directory of Open Access Journals (Sweden)

    D. Saheb-Koussa

    2015-08-01

    Full Text Available      In engineering, simulation is an effective and economical, commonly used to make preliminary or comparative studies, both during development (design and normal operation of systems. Currently, several simulation tools, using HOMER, are used in academia. Thus, in this work, we present the principle of feasibility study and optimization of a stand alone hybrid system (wind-photovoltaic-diesel. Furthermore, we determined the price per kWh of electricity supplied by the stand alone hybrid system, which amounts to $ 1417 / kWh. The site considered in this study represents the Adrar site located in the south west Algeria. Thus, we have inferred from this work as part of a configuration of the stand alone hybrid system obviously depends on available energy resources and constraints. On the other hand we have highlighted the role of the renewable energy uses in reducing emissions of greenhouse gas (CO2 rate = 16086 kg / year for a system using only the generator diesel and is 599 kg / year for the stand alone hybrid system studied.

  8. Segmental kyphosis after cervical interbody fusion with stand-alone polyetheretherketone (PEEK) cages: a comparative study on 2 different PEEK cages.

    Science.gov (United States)

    Kim, Chi Heon; Chung, Chun Kee; Jahng, Tae-Ahn; Park, Sung Bae; Sohn, Seil; Lee, Sungjoon

    2015-02-01

    Retrospective comparative study. Two polyetheretherketone (PEEK) cages of different designs were compared in terms of the postoperative segmental kyphosis after anterior cervical discectomy and fusion. Segmental kyphosis occasionally occurs after the use of a stand-alone cage for anterior cervical discectomy and fusion. Although PEEK material seems to have less risk of segmental kyphosis compared with other materials, the occurrence of segmental kyphosis for PEEK cages has been reported to be from 0% to 29%. There have been a few reports that addressed the issue of PEEK cage design. A total of 41 consecutive patients who underwent single-level anterior discectomy and fusion with a stand-alone cage were included. Either a round tube-type (Solis; 18 patients, S-group) or a trapezoidal tube-type (MC+; 23 patients, M-group) cage was used. The contact area between the cage and the vertebral body is larger in MC+ than in Solis, and anchoring pins were present in the Solis cage. The effect of the cage type on the segmental angle (SA) (lordosis vs. kyphosis) at postoperative month 24 was analyzed. Preoperatively, segmental lordosis was present in 12/18 S-group and 16/23 M-group patients (P=0.84). The SA was more lordotic than the preoperative angle in both groups just after surgery, with no difference between groups (P=0.39). At 24 months, segmental lordosis was observed in 9/18 S-group and 20/23 M-group patients (P=0.01). The patients in M-group were 7.83 times more likely than patients in S-group (P=0.04; odds ratio, 7.83; 95% confidence interval, 1.09-56.28) not to develop segmental kyphosis. The design of the PEEK cage used may influence the SA, and this association needs to be considered when using stand-alone PEEK cages.

  9. Clinician's perspectives of the relocation of a regional child and adolescent mental health service from co-located to stand alone premises.

    Science.gov (United States)

    Francis, K J; Boyd, C P; Sewell, J; Nurse, S

    2008-01-01

    Australia's National Mental Health Strategy's statement of rights and responsibilities states that children and adolescents admitted to a mental health facility or community program have the right to be separated from adult patients and provided with programs suited to their developmental needs. However, in rural Australia, where a lack of healthcare services, financial constraints, greater service delivery areas and fewer mental healthcare specialists represent the norm, Child and Adolescent Mental Health Services (CAMHS) are sometimes co-located with adult mental health services. The aim of the present study was to evaluate the impact of a recent relocation of a regional CAMHS in Victoria from co-located to stand alone premises. Six CAMHS clinicians who had experienced service delivery at a co-located setting and the current stand-alone CAMHS setting were interviewed about their perceptions of the impact of the relocation on service delivery. An exploratory interviewing methodology was utilized due to the lack of previous research in this area. Interview data were transcribed and analysed according to interpretative phenomenological analysis techniques. Findings indicated a perception that the relocation was positive for clients due to the family-friendly environment at the new setting and separation of CAMHS from adult psychiatric services. However, the impact of the relocation on clinicians was marked by a perceived loss of social capital from adult psychiatric service clinicians. These results provide increased understanding of the effects of service relocation and the influence of co-located versus stand-alone settings on mental health service delivery - an area where little prior research exists.

  10. Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels.

    Science.gov (United States)

    Kao, Ting-Hsien; Wu, Chen-Hao; Chou, Yu-Ching; Chen, Hsien-Te; Chen, Wen-Hsien; Tsou, Hsi-Kai

    2014-10-01

    To determine risk factors for subsidence in patients treated with anterior cervical discectomy and fusion (ACDF) and stand-alone polyetheretherketone (PEEK) cages. Records of patients with degenerative spondylosis or traumatic disc herniation resulting in radiculopathy or myelopathy between C2 and C7 who underwent ACDF with stand-alone PEEK cages were retrospectively reviewed. Cages were filled with autogenous cancellous bone harvested from iliac crest or hydroxyapatite. Subsidence was defined as a decrease of 3 mm or more of anterior or posterior disc height from that measured on the postoperative radiograph. Eighty-two patients (32 males, 50 females; 182 treatment levels) were included in the analysis. Most patients had 1-2 treatment levels (62.2 %), and 37.8 % had 3-4 treatment levels. Treatment levels were from C2-7. Of the 82 patients, cage subsidence occurred in 31 patients, and at 39 treatment levels. Multivariable analysis showed that subsidence was more likely to occur in patients with more than two treatment levels, and more likely to occur at treatment levels C5-7 than at levels C2-5. Subsidence was not associated with postoperative alignment change but associated with more disc height change (relatively oversized cage). Subsidence is associated with a greater number of treatment levels, treatment at C5-7 and relatively oversized cage use.

  11. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O. [University Medical Centre Mannheim, Medical Faculty Mannheim-University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Reich, C.; Kaiser, W.A. [Friedrich-Schiller-University Hospital Jena, Institute of Diagnostic and Interventional Radiology I, Jena (Germany); Dietzel, M. [Friedrich-Alexander-University Hospital Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Baltzer, P.A.T. [Medical University Vienna, Institute of Radiology and Nuclear Medicine, Vienna (Austria)

    2015-06-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  12. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    International Nuclear Information System (INIS)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O.; Reich, C.; Kaiser, W.A.; Dietzel, M.; Baltzer, P.A.T.

    2015-01-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  13. Wireless network of stand-alone end effect probes for soil in situ permittivity measurements over the 100MHZ-6GHz frequency range

    Science.gov (United States)

    Demontoux, François; Bircher, Simone; Ruffié, Gilles; Bonnaudiin, Fabrice; Wigneron, Jean-Pierre; Kerr, Yann

    2017-04-01

    , it should be useful to install many probes on the same site to obtain permittivity measurements over a large area. To reach this goal, the probes should communicate with each other to send data to a record device. Furthermore, it is needed to record measurements over a long time period (many months) to study the in-situ dielectric soil property variations according to changing weather conditions and seasonal trends. The goal of the research work presented is to develop a dielectric sensor system based on end effect probes able to communicate the data using wireless technology. It must be stand-alone from an electric and data recording point of view so it must integrate a VNA circuit instead of the ANRITSU VNA used for the moment. The LoRa wireless technology has been selected because of its low electric consumption and the large distance between equipment available. LoRaWAN™ is a Low Power Wide Area Network specification intended for wireless battery operated devices. The LoRaWAN data rates range from 0.3 kbps to 50 kbps which is sufficient for our probes' data exchanges. We will present the work done to perform the VNA and the LoRa communication board as well as the work done to improve the probes and the permittivity computation algorithm.

  14. Is Cyberbullying a Stand Alone Construct? Using Quantitative Analysis to Evaluate a 21st Century Social Question

    Directory of Open Access Journals (Sweden)

    Ryan Randa

    2015-03-01

    Full Text Available Using a subsample of the 2009 National Crime Victimization Survey, School Crime Supplement (NCVS-SCS, the present study explores the nature of the relationship between cyberbullying and traditional bullying victimization among students aged 12–18. One question of particular interest in the recent cyberbullying literature regards the classification of cyberbullying relative to traditional school yard bullying. As is the case in the cyber victimization literature in general, the question has become whether cyberbullying is an extension of traditional bullying or whether it is a unique independent phenomenon. Using the available data we attempt to address this question by exploring cyberbullying victimization as a standalone construct. Results of exploratory factor analyses suggest that cyberbullying victimization is both interlaced with traditional bullying modalities, and experienced as a unique phenomenon. Our results contribute a 21st century texture and dimension to the traditional construct.

  15. Techno-economic assessment of FT unit for synthetic diesel production in existing stand-alone biomass gasification plant using process simulation tool

    DEFF Research Database (Denmark)

    Hunpinyo, Piyapong; Narataruksa, Phavanee; Tungkamani, Sabaithip

    2014-01-01

    For alternative thermo-chemical conversion process route via gasification, biomass can be gasified to produce syngas (mainly CO and H2). On more applications of utilization, syngas can be used to synthesize fuels through the catalytic process option for producing synthetic liquid fuels...... such as Fischer-Tropsch (FT) diesel. The embedding of the FT plant into the stand-alone based on power mode plants for production of a synthetic fuel is a promising practice, which requires an extensive adaptation of conventional techniques to the special chemical needs found in a gasified biomass. Because...... there are currently no plans to engage the FT process in Thailand, the authors have targeted that this work focus on improving the FT configurations in existing biomass gasification facilities (10 MWth). A process simulation model for calculating extended unit operations in a demonstrative context is designed...

  16. Effects of ozone as a stand-alone and coagulation-aid treatment on the reduction of trihalomethanes precursors from high DOC and hardness water.

    Science.gov (United States)

    Sadrnourmohamadi, Mehrnaz; Gorczyca, Beata

    2015-04-15

    This study investigates the effect of ozone as a stand-alone and coagulation aid on the removal of dissolved organic carbon (DOC) from the water with a high level of DOC (13.8 mgL(-1)) and calcium hardness (270 mgL(-1)) CaCO3. Natural water collected from the Assiniboine River (Manitoba, Canada) was used in this study. Effectiveness of ozone treatment was evaluated by measurement of DOC, DOC fractions, UV254, and trihalomethane formation potential (THMFP). Additionally, zeta potential and dissolved calcium concentration were measured to discern the mechanism of ozone reactions. Results indicated that 0.8 mg O3/mg DOC ozone stand-alone can cause up to 86% UV254 reduction and up to 27% DOC reduction. DOC fractionation results showed that ozone can change the composition of DOC in the water samples, converting the hydrophobic fractions into hydrophilic ones and resulting in the reduction of THMFP. Also, ozone caused a decrease in particle stability and dissolved calcium concentration. These simultaneous ozonation effects caused improved water flocculation and enhanced removal of DOC. This resulted in reduction of the coagulant dosage when ozone doses higher than 0.2 mg O3/mg DOC were applied prior to coagulation with ferric sulfate. Also, pre-ozonation-coagulation process achieved preferential THMFP removal for all of the ozone doses tested (0-0.8 mg O3/mg DOC), leading to a lower specific THMFP in pre-ozonated-coagulated waters than in the corresponding ozonated waters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Comparison of plate-cage construct and stand-alone anchored spacer in the surgical treatment of three-level cervical spondylotic myelopathy: a preliminary clinical study.

    Science.gov (United States)

    Shi, Sheng; Liu, Zu-De; Li, Xin-Feng; Qian, Lie; Zhong, Gui-Bin; Chen, Fang-Jing

    2015-09-01

    Although stand-alone cages were advocated to be superior to plate-cage construct (PCC) because of comparable clinical outcomes and fewer plate-related complications, cage dislocation and subsidence were frequently mentioned in multilevel fusion. There are some concerns about whether these issues can be effectively prevented in multilevel anterior cervical discectomy and fusion (ACDF) by stand-alone anchored spacer (SAAS). The aim was to compare clinical outcomes, radiologic parameters, and complications of PCC and SAAS in the treatment of three-level cervical spondylotic myelopathy (CSM). This was a retrospective comparative study. A total of 38 consecutive patients with three-level CSM (ACDF with PCC, 20 patients; ACDF with SAAS, 18 patients) were reviewed. Clinical outcomes were assessed using Japanese Orthopaedic Association and Neck Disability Index. The radiologic evaluations included cervical alignment (CA), segmental angle (SA), postoperative curvature loss (PCL), and incidence of subsidence. All the aforementioned parameters were compared before and after surgery between two groups. Besides, the aforementioned results were also compared between the two groups. The complications were also recorded. The mean follow-up period was 30.3 months. No significant differences were observed in clinical outcomes between the two groups (p>.05). Additionally, no significant differences existed in fusion rate between the two groups. There were significant differences in PCL of SA and CA and correction of SA between the two groups (pSAAS group, and the potential of SAAS to reduce the incidence of postoperative dysphagia was not proven. No other complications were observed in this study. In the surgical treatment of three-level CSM, PCC is superior to SAAS in correction and maintenance of SA and avoiding cage subsidence, although the technique of ACDF with SAAS yielded encouraging clinical outcomes and high fusion rate. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. PR2ALIGN: a stand-alone software program and a web-server for protein sequence alignment using weighted biochemical properties of amino acids.

    Science.gov (United States)

    Kuznetsov, Igor B; McDuffie, Michael

    2015-05-07

    Alignment of amino acid sequences is the main sequence comparison method used in computational molecular biology. The selection of the amino acid substitution matrix best suitable for a given alignment problem is one of the most important decisions the user has to make. In a conventional amino acid substitution matrix all elements are fixed and their values cannot be easily adjusted. Moreover, most existing amino acid substitution matrices account for the average (dis)similarities between amino acid types and do not distinguish the contribution of a specific biochemical property to these (dis)similarities. PR2ALIGN is a stand-alone software program and a web-server that provide the functionality for implementing flexible user-specified alignment scoring functions and aligning pairs of amino acid sequences based on the comparison of the profiles of biochemical properties of these sequences. Unlike the conventional sequence alignment methods that use 20x20 fixed amino acid substitution matrices, PR2ALIGN uses a set of weighted biochemical properties of amino acids to measure the distance between pairs of aligned residues and to find an optimal minimal distance global alignment. The user can provide any number of amino acid properties and specify a weight for each property. The higher the weight for a given property, the more this property affects the final alignment. We show that in many cases the approach implemented in PR2ALIGN produces better quality pair-wise alignments than the conventional matrix-based approach. PR2ALIGN will be helpful for researchers who wish to align amino acid sequences by using flexible user-specified alignment scoring functions based on the biochemical properties of amino acids instead of the amino acid substitution matrix. To the best of the authors' knowledge, there are no existing stand-alone software programs or web-servers analogous to PR2ALIGN. The software is freely available from http://pr2align.rit.albany.edu.

  19. NMFS Fishery-Independent Survey System (FINSS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fishery Independent Survey System (FINSS) is a national system that characterizes NMFS ocean observation activities, stock and ecosystem data collections during...

  20. GOssTo: a stand-alone application and a web tool for calculating semantic similarities on the Gene Ontology

    OpenAIRE

    Caniza, Horacio; Romero, Alfonso E.; Heron, Samuel; Yang, Haixuan; Devoto, Alessandra; Frasca, Marco; Mesiti, Marco; Valentini, Giorgio; Paccanaro, Alberto

    2014-01-01

    Summary: We present GOssTo, the Gene Ontology semantic similarity Tool, a user-friendly software system for calculating semantic similarities between gene products according to the Gene Ontology. GOssTo is bundled with six semantic similarity measures, including both term- and graph-based measures, and has extension capabilities to allow the user to add new similarities. Importantly, for any measure, GOssTo can also calculate the Random Walk Contribution that has been shown to greatly improve...

  1. Lighting up the villages: Livelihood impacts of decentralized stand-alone solar photovoltaic electrification in rural northern Ghana

    Directory of Open Access Journals (Sweden)

    Naah John-Baptist Saabado Ngmaadaba

    2015-01-01

    Full Text Available The dynamics of solar photovoltaic (PV technology dissemination and utilization has taken center stage in recent years on a global scale, aiming to partly address prevailing rampant energy poverty situations particularly in developing countries. This paper evaluates a flagship electrification project called Ghana Energy Development and Access Project (GEDAP. We purposively sampled 250 solar users in 65 villages across 6 districts in the Upper West region which has the country’s lowest level of electricity access and possibly the highest proportion of abject poverty among its inhabitants compared to the rest of the country. Based on the survey, it can be said that the overall impact assessment of the GEDAP-sponsored off-grid solar PV systems on the quality of life of the local beneficiaries was found to be positively marginal. Among all livelihood assets considered, social capital was markedly enhanced by the provision of modern energy services via isolated solar PV systems. Bottlenecks were identified, including limited system wattage capacity, slight dysfunction of some balance of components, higher interest rates, low technical know-how and inadequate monitoring, all of which are negatively affecting the sustainability of the project. Our findings also indicate that satisfaction derived from solar PV electricity supply among local solar customers differed for varied reasons as follows: moderately satisfied (43%, satisfied (52%, and dissatisfied (5%. For a decisive enhancement of rural livelihoods, we strongly recommend up-scaling system wattage capacity and coverage to build up new or improve upon existing livelihood assets through diversification of the income sources of the local inhabitants.

  2. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: A Preliminary Feasibility Demonstration

    Science.gov (United States)

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Mazzoni, Augusto; Crespi, Mattia; Wei, Yong; Mannucci, Anthony J.

    2017-04-01

    It is well known that tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances can be studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and estimate slant TEC (sTEC) variations in a real-time scenario. Using the VARION algorithm we compute TEC variations at 56 GPS receivers in Hawaii as induced by the 2012 Haida Gwaii tsunami event. We observe TEC perturbations with amplitudes of up to 0.25 TEC units and traveling ionospheric perturbations (TIDs) moving away from the earthquake epicenter at an approximate speed of 316 m/s. We perform a wavelet analysis to analyze localized variations of power in the TEC time series and we find perturbation periods consistent with a tsunami typical deep ocean period. Finally, we present comparisons with the real-time tsunami MOST (Method of Splitting Tsunami) model produced by the NOAA Center for Tsunami Research and we observe variations in TEC that correlate in time and space with the tsunami waves.

  3. What is Happening with Independent System Operators?

    Energy Technology Data Exchange (ETDEWEB)

    Porter, K. L.

    1999-02-01

    Emerging independent system operators (ISOs) appear to have many advantages for the wind power industry. This paper compares some past research on wind and transmission issues with some of the developments in ISO design and implementation.

  4. Controleum - an independently extensible control system

    DEFF Research Database (Denmark)

    Jensen, Martin Lykke Rytter

    2014-01-01

    challenging kind of system to design for independent extension. This thesis presents two new software technologies that improve the extensibility of control systems: First, the concept of dynamic links is introduced and Decouplink – an implementation of dynamic links for Java - is presented. Dynamic links...... is introduced, and an implementation is presented. The extensible controller is a component framework designed to automatically resolve conflicts among mutually unaware components in a control system. The solution is based on the idea that independent components implement different kinds of control concerns...

  5. Stand-Alone Containment Analysis of the Phébus FPT Tests with the ASTEC and the MELCOR Codes: The FPT-0 Test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2017-01-01

    Full Text Available The integral Phébus tests were probably one of the most important experimental campaigns performed to investigate the progression of severe accidents in light water reactors. In these tests, the degradation of a PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the results of such tests, numerical codes such as ASTEC and MELCOR have been developed to describe the evolution of a severe accident. After the termination of the experimental Phébus campaign, these two codes were furthermore expanded. Therefore, the aim of the present work is to reanalyze the first Phébus test (FPT-0 employing the updated ASTEC and MELCOR versions to ensure that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The analysis focuses on the stand-alone containment aspects of this test, and the paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products behavior. This paper is part of a series of publications covering the four executed Phébus tests employing a solid PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3.

  6. The international phase 4 validation study of the EORTC QLQ-SWB32: A stand-alone measure of spiritual well-being for people receiving palliative care for cancer

    NARCIS (Netherlands)

    Vivat, B.; Young, T. E.; Winstanley, J.; Arraras, J. I.; Black, K.; Boyle, F.; Bredart, A.; Costantini, A.; Guo, J.; Irarrazaval, M. E.; Kobayashi, K.; Kruizinga, R.; Navarro, M.; Omidvari, S.; Rohde, G. E.; Serpentini, S.; Spry, N.; van Laarhoven, H. W. M.; Yang, G. M.

    2017-01-01

    The EORTC Quality of Life Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual well-being (SWB) for palliative cancer patients. Participants (n = 451)-from 14 countries on four continents; 54% female; 188

  7. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  8. Effects of a stand-alone web-based electronic screening and brief intervention targeting alcohol use in university students of legal drinking age: A randomized controlled trial.

    Science.gov (United States)

    Ganz, Thomas; Braun, Michael; Laging, Marion; Schermelleh-Engel, Karin; Michalak, Johannes; Heidenreich, Thomas

    2018-02-01

    Many intervention efforts targeting student drinking were developed to address US college students, which usually involves underage drinking. It remains unclear, if research evidence from these interventions is generalizable to university and college students of legal drinking age, e.g., in Europe. To evaluate the effectiveness of a translated and adapted version of the eCHECKUP TO GO, applied as stand-alone web-based electronic screening and brief intervention (e-SBI), in German university students at risk for hazardous drinking. A fully automated web-based two-arm parallel-group randomized controlled trial was conducted. Participants were randomized to an e-SBI or assessment-only (AO) condition. The current paper analyzed students with baseline AUDIT-C scores ≥3 for women and ≥4 for men (sample at baseline: e-SBI [n=514], AO [n=467]; 3-month follow-up: e-SBI [n=194], AO [n=231]; 6-month follow-up: e-SBI [n=146], AO [n=200]). The primary outcome was prior four weeks' alcohol consumption. Secondary outcomes were frequency of heavy drinking occasions, peak blood alcohol concentration, and number of alcohol-related problems. Mixed linear model analyses revealed significant interaction effects between groups and time points on the primary outcome after 3 and 6months. Compared to students in the AO condition, students in the e-SBI condition reported consuming 4.11 fewer standard drinks during the previous four weeks after 3months, and 4.78 fewer standard drinks after 6months. Mixed results were found on secondary outcomes. The results indicate that evidence on and knowledge of web-based e-SBIs based on US college student samples is transferable to German university students of legal drinking age. However, knowledge of what motivates students to complete programs under voluntary conditions, although rare, is needed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test.

    Science.gov (United States)

    Gonfiotti, Bruno; Paci, Sandro

    2018-03-01

    During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA) in a Nuclear Power Plant (NPP). Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR) fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV) have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP) behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel.

  10. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2018-03-01

    Full Text Available During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA in a Nuclear Power Plant (NPP. Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel. Keywords: Safety

  11. Smile (System/Machine-Independent Local Environment)

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.G.

    1988-04-01

    This document defines the characteristics of Smile, a System/machine-independent local environment. This environment consists primarily of a number of primitives (types, macros, procedure calls, and variables) that a program may use; these primitives provide facilities, such as memory allocation, timing, tasking and synchronization beyond those typically provided by a programming language. The intent is that a program will be portable from system to system and from machine to machine if it relies only on the portable aspects of its programming language and on the Smile primitives. For this to be so, Smile itself must be implemented on each system and machine, most likely using non-portable constructions; that is, while the environment provided by Smile is intended to be portable, the implementation of Smile is not necessarily so. In order to make the implementation of Smile as easy as possible and thereby expedite the porting of programs to a new system or a new machine, Smile has been defined to provide a minimal portable environment; that is, simple primitives are defined, out of which more complex facilities may be constructed using portable procedures. The implementation of Smile can be as any of the following: the underlying software environment for the operating system of an otherwise {open_quotes}bare{close_quotes} machine, a {open_quotes}guest{close_quotes} system environment built upon a preexisting operating system, an environment within a {open_quotes}user{close_quotes} process run by an operating system, or a single environment for an entire machine, encompassing both system and {open_quotes}user{close_quotes} processes. In the first three of these cases the tasks provided by Smile are {open_quotes}lightweight processes{close_quotes} multiplexed within preexisting processes or the system, while in the last case they also include the system processes themselves.

  12. Partitioning a macroscopic system into independent subsystems

    Science.gov (United States)

    Delle Site, Luigi; Ciccotti, Giovanni; Hartmann, Carsten

    2017-08-01

    We discuss the problem of partitioning a macroscopic system into a collection of independent subsystems. The partitioning of a system into replica-like subsystems is nowadays a subject of major interest in several fields of theoretical and applied physics. The thermodynamic approach currently favoured by practitioners is based on a phenomenological definition of an interface energy associated with the partition, due to a lack of easily computable expressions for a microscopic (i.e. particle-based) interface energy. In this article, we outline a general approach to derive sharp and computable bounds for the interface free energy in terms of microscopic statistical quantities. We discuss potential applications in nanothermodynamics and outline possible future directions.

  13. Systems analysis-independent analysis and verification

    Energy Technology Data Exchange (ETDEWEB)

    Badin, J.S.; DiPietro, J.P. [Energetics, Inc., Columbia, MD (United States)

    1995-09-01

    The DOE Hydrogen Program is supporting research, development, and demonstration activities to overcome the barriers to the integration of hydrogen into the Nation`s energy infrastructure. Much work is required to gain acceptance of hydrogen energy system concepts and to develop them for implementation. A systems analysis database has been created that includes a formal documentation of technology characterization profiles and cost and performance information. Through a systematic and quantitative approach, system developers can understand and address important issues and thereby assure effective and timely commercial implementation. This project builds upon and expands the previously developed and tested pathway model and provides the basis for a consistent and objective analysis of all hydrogen energy concepts considered by the DOE Hydrogen Program Manager. This project can greatly accelerate the development of a system by minimizing the risk of costly design evolutions, and by stimulating discussions, feedback, and coordination of key players and allows them to assess the analysis, evaluate the trade-offs, and to address any emerging problem areas. Specific analytical studies will result in the validation of the competitive feasibility of the proposed system and identify system development needs. Systems that are investigated include hydrogen bromine electrolysis, municipal solid waste gasification, electro-farming (biomass gasifier and PEM fuel cell), wind/hydrogen hybrid system for remote sites, home electrolysis and alternate infrastructure options, renewable-based electrolysis to fuel PEM fuel cell vehicle fleet, and geothermal energy used to produce hydrogen. These systems are compared to conventional and benchmark technologies. Interim results and findings are presented. Independent analyses emphasize quality, integrity, objectivity, a long-term perspective, corporate memory, and the merging of technical, economic, operational, and programmatic expertise.

  14. Study of Systems and Technology for Liquid Hydrogen Production Independent of Fossil Fuels

    Science.gov (United States)

    Sprafka, R. J.; Escher, W. J. D.; Foster, R. W.; Tison, R. R.; Shingleton, J.; Moore, J. S.; Baker, C. R.

    1983-01-01

    Based on Kennedy Space Center siting and logistics requirements and the nonfossil energy resources at the Center, a number of applicable technologies and system candidates for hydrogen production were identified and characterized. A two stage screening of these technologies in the light of specific criteria identified two leading candidates as nonfossil system approaches. Conceptual design and costing of two solar-operated, stand alone systems, one photovoltaic based on and the other involving the power tower approach reveals their technical feasibility as sited as KSC, and the potential for product cost competitiveness with conventional supply approaches in the 1990 to 1210 time period. Conventional water hydrolysis and hydrogen liquefaction subsystems are integrated with the solar subsystems.

  15. Independent System Calibration of Sentinel-1B

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2017-05-01

    Full Text Available Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR satellites of the Sentinel-1 mission, launched in April 2016—two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA, an independent system calibration was performed by the German Aerospace Center (DLR on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR’s reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.

  16. Independent System Operators and Biomass Power

    International Nuclear Information System (INIS)

    Porter, Kevin L.

    1999-01-01

    Since the Federal Energy Regulatory Commission issued its landmark open access transmission rule in 1996, the idea of creating and establishing independent system operators (ISOs) has gained momentum. ISOs may help combine individual utility transmission systems into more regional transmission networks, which ultimately will allow biomass companies to transmit power over longer distances while paying a single transmission rate. To the extent that ISOs are combined or operated with power exchanges, however, biomass companies will likely face even more competitive market pressures. Few operators have experience with ISOs and power exchanges, but preliminary results show that short-term electricity market prices are probably too low for most biomass companies to compete against. Without policy measures, biomass companies may have to pursue strategic opportunities with short-term, spot-market sales; direct bilateral sales to customers; alternative power exchanges; and perhaps a ''green'' power market and sales to ancillary service markets. In addition, prices will likely be more volatile in a restructured market so biomass generators should be selling during those times

  17. Build Rocky Flats Environmental Technology site production prototype modular treatment system for stand alone core capability for residue unpack, sort, assay, repack

    International Nuclear Information System (INIS)

    Hildner, R.A.; Zygmunt, S.J.

    1997-01-01

    This document describes a portable and modular suit of equipment that upfront and near-term accomplishes a sorting process that documents and removes Rocky Flats Environmental Technology Site (RFETS) residue and waste from site inventory

  18. The international phase 4 validation study of the EORTC QLQ-SWB32: a stand-alone measure of spiritual wellbeing (SWB) for people receiving palliative care for cancer

    OpenAIRE

    Vivat, B.; Young, T.; Winstanley, J.; Arraras, J.; Black, K.; Boyle, F.; Brédart, A.; Costantini, A.; Guo, J.; Irarrazaval, M. E.; Kobayashi, K.; Kruizinga, R.; Navarro, M.; Omidvari, S.; Rohde, G. E.

    2017-01-01

    The EORTC Quality of Life (QL) Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual wellbeing (SWB) for palliative cancer patients. Participants (n= 451) - from 14 countries on four continents; 54% female; 188 Christian, 50 Muslim, 156 with no religion - completed a provisional 36-item measure of SWB plus the EORTC QLQ-C15-PAL (PAL), then took part in a structured debriefing interview. All items showe...

  19. Control system for the NBS microtron accelerator

    International Nuclear Information System (INIS)

    Martin, E.R.; Trout, R.E.; Wilson, B.L.; Ayres, R.L.; Yoder, N.R.

    1985-01-01

    As various subsystems of the National Bureau of Standards/Los Alamos racetrack microtron accelerator are being brought on-line, we are gaining experience with some of the innovations implemented in the control system. Foremost among these are the joystick-based operator controls, the hierarchical distribution of control system intelligence, and the independent secondary stations, permitting sectional stand-alone operation. The result of the distributed database philosophy and parallel data links has been very fast data updates, permitting joystick interaction with system elements. The software development was greatly simplified by using the hardware arbitration of several parallel processors in the Multibus system to split the software tasks into independent modules

  20. Independent Navigation System for a Surgical Colonoscope

    Directory of Open Access Journals (Sweden)

    Lilia A. Ochoa-Luna

    2013-08-01

    Full Text Available This paper provides a novel algorithm to attain the independent navigation of a colonoscopy surgical endoscope. First, it introduces a brief description of this issue through the scientist advance for medical robotics. It then makes a quickly count of the existent methods and at the end it provides the basis in order to propose a new alternative solution with help from vision-guidance. That means that images will be processed and interpreted with the purpose of maintaining the endoscope always at the intestine center. All this considered will help us to reduce colonoscopy surgeries consequences and the most important advantage of this new method proposed is that surgeons will accomplish their work easier and more efficiently.

  1. Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring.

    Science.gov (United States)

    Zajonz, Dirk; Franke, Anne-Catherine; von der Höh, Nicolas; Voelker, Anna; Moche, Michael; Gulow, Jens; Heyde, Christoph-Eckhard

    2014-01-01

    The stand-alone treatment of degenerative cervical spine pathologies is a proven method in clinical practice. However, its impact on subsidence, the resulting changes to the profile of the cervical spine and the possible influence of clinical results compared to treatment with additive plate osteosynthesis remain under discussion until present. This study was designed as a retrospective observational cohort study to test the hypothesis that radiographic subsidence of cervical cages is not associated with adverse clinical outcomes. 33 cervical segments were treated surgically by ACDF with stand-alone cage in 17 patients (11 female, 6 male), mean age 56 years (33-82 years), and re-examined after eight and twenty-six months (mean) by means of radiology and score assessment (Medical Outcomes Study Short Form (MOS-SF 36), Oswestry Neck Disability Index (ONDI), painDETECT questionnaire and the visual analogue scale (VAS)). Subsidence was observed in 50.5% of segments (18/33) and 70.6% of patients (12/17). 36.3% of cases of subsidence (12/33) were observed after eight months during mean time of follow-up 1. After 26 months during mean time of follow-up 2, full radiographic fusion was seen in 100%. MOS-SF 36, ONDI and VAS did not show any significant difference between cases with and without subsidence in the two-sample t-test. Only in one type of scoring (painDETECT questionnaire) did a statistically significant difference in t-Test emerge between the two groups (p = 0.03; α = 0.05). However, preoperative painDETECT score differ significantly between patients with subsidence (13.3 falling to 12.6) and patients without subsidence (7.8 dropped to 6.3). The radiological findings indicated 100% healing after stand-alone treatment with ACDF. Subsidence occurred in 50% of the segments treated. No impact on the clinical results was detected in the medium-term study period.

  2. Systems analysis - independent analysis and verification

    Energy Technology Data Exchange (ETDEWEB)

    DiPietro, J.P.; Skolnik, E.G.; Badin, J.S. [Energetics, Inc., Columbia, MD (United States)

    1996-10-01

    The Hydrogen Program of the U.S. Department of Energy (DOE) funds a portfolio of activities ranging from conceptual research to pilot plant testing. The long-term research projects support DOE`s goal of a sustainable, domestically based energy system, and the development activities are focused on hydrogen-based energy systems that can be commercially viable in the near-term. Energetics develops analytic products that enable the Hydrogen Program Manager to assess the potential for near- and long-term R&D activities to satisfy DOE and energy market criteria. This work is based on a pathway analysis methodology. The authors consider an energy component (e.g., hydrogen production from biomass gasification, hybrid hydrogen internal combustion engine (ICE) vehicle) within a complete energy system. The work involves close interaction with the principal investigators to ensure accurate representation of the component technology. Comparisons are made with the current cost and performance of fossil-based and alternative renewable energy systems, and sensitivity analyses are conducted to determine the effect of changes in cost and performance parameters on the projects` viability.

  3. Design and testing of an independently controlled urea SCR retrofit system for the reduction of NOx emissions from marine diesels.

    Science.gov (United States)

    Johnson, Derek R; Bedick, Clinton R; Clark, Nigel N; McKain, David L

    2009-05-15

    Diesel engine emissions for on-road, stationary and marine applications are regulated in the United States via standards set by the Environmental Protection Agency (EPA). A major component of diesel exhaust that is difficult to reduce is nitrogen oxides (NOx). Selective catalytic reduction (SCR) has been in use for many years for stationary applications, including external combustion boilers, and is promising for NOx abatement as a retrofit for mobile applications where diesel compression ignition engines are used. The research presented in this paper is the first phase of a program focused on the reduction of NOx by use of a stand-alone urea injection system, applicable to marine diesel engines typical of work boats (e.g., tugs). Most current urea SCR systems communicate with engine controls to predict NOx emissions based on signals such as torque and engine speed, however many marine engines in use still employ mechanical injection technology and lack electronic communication abilities. The system developed and discussed in this paper controls NOx emissions independentof engine operating parameters and measures NOx and exhaust flow using the following exhaust sensor inputs: absolute pressure, differential pressure, temperature, and NOx concentration. These sensor inputs were integrated into an independent controller and open loop architecture to estimate the necessary amount of urea needed, and the controller uses pulse width modulation (PWM) to power an automotive fuel injector for airless urea delivery. The system was tested in a transient test cell on a 350 hp engine certified at 4 g/bhp-hr of NOx, with a goal of reducing the engine out NOx levels by 50%. NOx reduction capabilities of 41-67% were shown on the non road transient cycle (NRTC) and ICOMIA E5 steady state cycles with system optimization during testing to minimize the dilute ammonia slip to cycle averages of 5-7 ppm. The goal of 50% reduction of NOx can be achieved dependent upon cycle. Further

  4. Stand-alone polarization-modulation infrared reflection absorption spectroscopy instrument optimized for the study of catalytic processes at elevated pressures

    Science.gov (United States)

    Kestell, John D.; Mudiyanselage, Kumudu; Ye, Xinyi; Nam, Chang-Yong; Stacchiola, Dario; Sadowski, Jerzy; Boscoboinik, J. Anibal

    2017-10-01

    This paper describes the design and construction of a compact, "user-friendly" polarization-modulation infrared reflection absorption spectroscopy (PM-IRRAS) instrument at the Center for Functional Nanomaterials (CFN) of Brookhaven National Laboratory, which allows studying surfaces at pressures ranging from ultra-high vacuum to 100 Torr. Surface infrared spectroscopy is ideally suited for studying these processes as the vibrational frequencies of the IR chromophores are sensitive to the nature of the bonding environment on the surface. Relying on the surface selection rules, by modulating the polarization of incident light, it is possible to separate the contributions from the isotropic gas or solution phase, from the surface bound species. A spectral frequency range between 1000 cm-1 and 4000 cm-1 can be acquired. While typical spectra with a good signal to noise ratio can be obtained at elevated pressures of gases in ˜2 min at 4 cm-1 resolution, we have also acquired higher resolution spectra at 0.25 cm-1 with longer acquisition times. By way of verification, CO uptake on a heavily oxidized Ru(0001) sample was studied. As part of this test study, the presence of CO adsorbed on Ru bridge sites was confirmed, in agreement with previous ambient pressure X ray photoelectron spectroscopy studies. In terms of instrument performance, it was also determined that the gas phase contribution from CO could be completely removed even up to pressures close to 100 Torr. A second test study demonstrated the use of the technique for studying morphological properties of a spin coated polymer on a conductive surface. Note that this is a novel application of this technique. In this experiment, the polarization of incident light was modulated manually (vs. through a photoelastic modulator). It was demonstrated, in good agreement with the literature, that the polymer chains preferentially lie parallel with the surface. This PM-IRRAS system is small, modular, and easily

  5. Impact of air-sea drag coefficient for latent heat flux on large scale climate in coupled and atmosphere stand-alone simulations

    Science.gov (United States)

    Torres, Olivier; Braconnot, Pascale; Marti, Olivier; Gential, Luc

    2018-05-01

    The turbulent fluxes across the ocean/atmosphere interface represent one of the principal driving forces of the global atmospheric and oceanic circulation. Despite decades of effort and improvements, representation of these fluxes still presents a challenge due to the small-scale acting turbulent processes compared to the resolved scales of the models. Beyond this subgrid parameterization issue, a comprehensive understanding of the impact of air-sea interactions on the climate system is still lacking. In this paper we investigates the large-scale impacts of the transfer coefficient used to compute turbulent heat fluxes with the IPSL-CM4 climate model in which the surface bulk formula is modified. Analyzing both atmosphere and coupled ocean-atmosphere general circulation model (AGCM, OAGCM) simulations allows us to study the direct effect and the mechanisms of adjustment to this modification. We focus on the representation of latent heat flux in the tropics. We show that the heat transfer coefficients are highly similar for a given parameterization between AGCM and OAGCM simulations. Although the same areas are impacted in both kind of simulations, the differences in surface heat fluxes are substantial. A regional modification of heat transfer coefficient has more impact than uniform modification in AGCM simulations while in OAGCM simulations, the opposite is observed. By studying the global energetics and the atmospheric circulation response to the modification, we highlight the role of the ocean in dampening a large part of the disturbance. Modification of the heat exchange coefficient modifies the way the coupled system works due to the link between atmospheric circulation and SST, and the different feedbacks between ocean and atmosphere. The adjustment that takes place implies a balance of net incoming solar radiation that is the same in all simulations. As there is no change in model physics other than drag coefficient, we obtain similar latent heat flux

  6. Concept of a Stand-Alone Muon Trigger with High Transverse Momentum Resolution for the ATLAS Detector at the High-Luminosity LHC

    CERN Document Server

    Horii, Yasuyuki; The ATLAS collaboration

    2014-01-01

    The ATLAS trigger uses a three-level trigger system. The level-1 (L1) trigger for muons with high transverse momentum pT in ATLAS is based on fast chambers with excellent time resolution which are able to identify muons coming from a particular beam crossing. These trigger chambers also provide a fast measurement of the muon transverse momenta, however with limited accuracy caused by the moderate spatial resolution along the deflecting direction of the magnetic field. The higher luminosity foreseen for Phase-II puts stringent limits on the L1 trigger rates. A way to control these rates is the improvement of the spatial resolution of the triggering device which drastically sharpens the turn-on curve of the L1 trigger. To do this, the precision tracking chambers (MDT) can be used in the L1 trigger, if the corresponding trigger latency is increased as planned. The trigger rate reduction is accomplished by strongly decreasing the rate of triggers from muons with pT lower than a predefined threshold (typically 20 ...

  7. Stand alone biofuel production from algae

    NARCIS (Netherlands)

    Wijffels, R.H.; Janssen, M.G.J.; Barbosa, M.J.

    2011-01-01

    In this feature, leading researchers in the field of microbial biotechnology speculate on the technical and conceptual developments that will drive innovative research and open new vistas over the next few years

  8. Informing Approaches in Establishing Stand Alone Community ...

    African Journals Online (AJOL)

    Literacy is usually considered the ability to read at a basic level. Now it is beginning to be defined more broadly to include applying reading, writing, and mathematical skills to obtain and use information and solve problems at levels of proficiency necessary to function in society, to achieve one's goals and develop one's ...

  9. Chapter 2: Stand-alone Applications - TOPCAT

    Science.gov (United States)

    Miller, C. J.

    Tool for OPerations on Catalogues And Tables or TOPCAT is a graphical viewer for table data. It offers a variety of ways to work with data tables, including a browser for the cell data, viewers for information about table and column metadata, dataset visualization, and even analysis. We discuss a small subset of TOPCAT's functionalities in this chapter. TOPCAT was originally developed as part of the Starlink program in the United Kingdom. It is now maintained by AstroGrid. The program is written in pure Java and available under the GNU General Public License. It is available for download and a version is included in the software distribution accompanying this book. TOPCAT is a GUI interface on top of the STIL library. A command line interface to this library, STILTS, described in Chapter 21 provides scriptable access to many of the capabilities described here. The purpose of this tutorial is to provide an overview of TOPCAT to the novice user. The best place to look for and learn about TOPCAT is the web page maintained by Mark B. Taylor. There, TOPCAT documentation is provided in HTML, PDF, via screen shots, etc. In this chapter we take the user through a few examples that give the general idea of how TOPCAT works. The majority of the functionality of TOPCAT is not included in this short tutorial. Our goal in this tutorial is to lead the reader through an exercise that would result in a publication quality figure (e.g. for a journal article). Specifically, we will use TOPCAT to show how the color-magnitude relation of a galaxy cluster compares to that of all galaxies in the Sloan Digital Sky Survey (York et al. 2000). This diagnostic is used not only in cluster finding, but its linear fit can provide insight into the age and/or metallicity of the oldest galaxies in galaxy clusters (which are some of the oldest galaxies in the Universe). The data we need for this exercise are: 1) the entire spectroscopic galaxy catalog from the SDSS, with galaxy positions, galaxy redshifts, and galaxy magnitudes and 2) galaxy members of a known galaxy cluster. For the former, we will download data directly from the SDSS servers to our local machine for analysis. For the latter, we will use TOPCAT's ability to call live cone search services.

  10. The international phase 4 validation study of the EORTC QLQ-SWB32: A stand-alone measure of spiritual well-being for people receiving palliative care for cancer.

    Science.gov (United States)

    Vivat, B; Young, T E; Winstanley, J; Arraras, J I; Black, K; Boyle, F; Bredart, A; Costantini, A; Guo, J; Irarrazaval, M E; Kobayashi, K; Kruizinga, R; Navarro, M; Omidvari, S; Rohde, G E; Serpentini, S; Spry, N; Van Laarhoven, H W M; Yang, G M

    2017-11-01

    The EORTC Quality of Life Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual well-being (SWB) for palliative cancer patients. Participants (n = 451)-from 14 countries on four continents; 54% female; 188 Christian; 50 Muslim; 156 with no religion-completed a provisional 36-item measure of SWB plus the EORTC QLQ-C15-PAL (PAL), then took part in a structured debriefing interview. All items showed good score distribution across response categories. We assessed scale structure using principal component analysis and Rasch analysis, and explored construct validity, and convergent/divergent validity with the PAL. Twenty-two items in four scoring scales (Relationship with Self, Relationships with Others, Relationship with Someone or Something Greater, and Existential) explained 53% of the variance. The measure also includes a global SWB item and nine other items. Scores on the PAL global quality-of-life item and Emotional Functioning scale weakly-moderately correlated with scores on the global SWB item and two of the four SWB scales. This new validated 32-item SWB measure addresses a distinct aspect of quality-of-life, and is now available for use in research and clinical practice, with a role as both a measurement and an intervention tool. © 2017 John Wiley & Sons Ltd.

  11. The frequency-independent control method for distributed generation systems

    DEFF Research Database (Denmark)

    Naderi, Siamak; Pouresmaeil, Edris; Gao, Wenzhong David

    2012-01-01

    In this paper a novel frequency-independent control method suitable for distributed generation (DG) is presented. This strategy is derived based on the . abc/. αβ transformation and . abc/. dq transformation of the ac system variables. The active and reactive currents injected by the DG are contr......In this paper a novel frequency-independent control method suitable for distributed generation (DG) is presented. This strategy is derived based on the . abc/. αβ transformation and . abc/. dq transformation of the ac system variables. The active and reactive currents injected by the DG...

  12. Systems and Methods for Gravity-Independent Gripping and Drilling

    Science.gov (United States)

    Parness, Aaron (Inventor); Frost, Matthew A. (Inventor); Thatte, Nitish (Inventor); King, Jonathan P. (Inventor)

    2016-01-01

    Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

  13. Hybrid synchronization of two independent chaotic systems on ...

    Indian Academy of Sciences (India)

    The real network nodes are always interfered by other messages. So, how to realize the hybrid synchronization of two independent chaotic systems based on the complex network is very important. To solve this problem, two other problems should be considered. One is how the same network node of the complex network ...

  14. Capital Investment by Independent and System-Affiliated Hospitals.

    Science.gov (United States)

    Carroll, Nathan W; Smith, Dean G; Wheeler, John R C

    2015-01-01

    Capital expenditures are a critical part of hospitals' efforts to maintain quality of patient care and financial stability. Over the past 20 years, finding capital to fund these expenditures has become increasingly challenging for hospitals, particularly independent hospitals. Independent hospitals struggling to find ways to fund necessary capital investment are often advised that their best strategy is to join a multi-hospital system. There is scant empirical evidence to support the idea that system membership improves independent hospitals' ability to make capital expenditures. Using data from the American Hospital Association and Medicare Cost Reports, we use difference-in-difference methods to examine changes in capital expenditures for independent hospitals that joined multi-hospital systems between 1997 and 2008. We find that in the first 5 years after acquisition, capital expenditures increase by an average of almost $16,000 per bed annually, as compared with non-acquired hospitals. In later years, the difference in capital expenditure is smaller and not statistically significant. Our results do not suggest that increases in capital expenditures vary by asset age or the size of the acquiring system. © The Author(s) 2015.

  15. Capital Investment by Independent and System-Affiliated Hospitals

    Science.gov (United States)

    Carroll, Nathan W.; Smith, Dean G.; Wheeler, John R. C.

    2015-01-01

    Capital expenditures are a critical part of hospitals’ efforts to maintain quality of patient care and financial stability. Over the past 20 years, finding capital to fund these expenditures has become increasingly challenging for hospitals, particularly independent hospitals. Independent hospitals struggling to find ways to fund necessary capital investment are often advised that their best strategy is to join a multi-hospital system. There is scant empirical evidence to support the idea that system membership improves independent hospitals’ ability to make capital expenditures. Using data from the American Hospital Association and Medicare Cost Reports, we use difference-in-difference methods to examine changes in capital expenditures for independent hospitals that joined multi-hospital systems between 1997 and 2008. We find that in the first 5 years after acquisition, capital expenditures increase by an average of almost $16 000 per bed annually, as compared with non-acquired hospitals. In later years, the difference in capital expenditure is smaller and not statistically significant. Our results do not suggest that increases in capital expenditures vary by asset age or the size of the acquiring system. PMID:26105571

  16. Effective time-independent analysis for quantum kicked systems

    Science.gov (United States)

    Bandyopadhyay, Jayendra N.; Guha Sarkar, Tapomoy

    2015-03-01

    We present a mapping of potentially chaotic time-dependent quantum kicked systems to an equivalent approximate effective time-independent scenario, whereby the system is rendered integrable. The time evolution is factorized into an initial kick, followed by an evolution dictated by a time-independent Hamiltonian and a final kick. This method is applied to the kicked top model. The effective time-independent Hamiltonian thus obtained does not suffer from spurious divergences encountered if the traditional Baker-Cambell-Hausdorff treatment is used. The quasienergy spectrum of the Floquet operator is found to be in excellent agreement with the energy levels of the effective Hamiltonian for a wide range of system parameters. The density of states for the effective system exhibits sharp peaklike features, pointing towards quantum criticality. The dynamics in the classical limit of the integrable effective Hamiltonian shows remarkable agreement with the nonintegrable map corresponding to the actual time-dependent system in the nonchaotic regime. This suggests that the effective Hamiltonian serves as a substitute for the actual system in the nonchaotic regime at both the quantum and classical level.

  17. Systems of independent Markov components and their transient behavior

    International Nuclear Information System (INIS)

    Keilson, J.

    1975-01-01

    The transient behavior of redundant systems of independent, repairable, memoryless (two state) components is studied. Four failure times for such systems are considered, each an exit time from the set of working states for initial system conditions of interest: the failure time from the perfect state, the post-recovery exit time, the ergodic exit time, and the quasi-stationary exit time. The structure of these failure time distributions and their interrelation are discussed and asymptotic estimates and bounds for their expectations are presented. When such systems have high reliability, the failure time distributions are approximately exponential and asymptotically equivalent

  18. EPICS: operating system independent device/driver support

    International Nuclear Information System (INIS)

    Kraimer, M.R.

    2003-01-01

    Originally EPICS input/output controllers (IOCs) were only supported on VME-based systems running the vxWorks operating system. Now IOCs are supported on many systems: vxWorks, RTEMS, Solaris, HPUX, Linux, WIN32, and Darwin. A challenge is to provide operating-system-independent device and driver support. This paper presents some techniques for providing such support. EPICS (Experimental Physics and Industrial Control System) is a set of software tools, libraries, and applications developed collaboratively and used worldwide to create distributed, real-time control systems for scientific instruments such as particle accelerators, telescopes, and other large scientific experiments. An important component of all EPICS-based control systems is a collection of input/output controllers (IOCs). An IOC has three primary components: (1) a real-time database; (2) channel access, which provides network access to the database; and (3) device/driver support for interfacing to equipment. This paper describes some projects related to providing device/driver support on non-vxWorks systems. In order to support IOCs on platforms other than vxWorks, operating-system-independent (OSI) application program interfaces (APIs) were defined for threads, semaphores, timers, etc. Providing support for a new platform consists of providing an operating-system-dependent implementation of the OSI APIs.

  19. Desiccant Dewpoint Cooling System Independent of External Water Sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Markussen, Wiebke B.

    2015-01-01

    the air that regenerates the desiccant dehumidifier, and using it for running the evaporative coolers in the system. A closed regeneration circuit is used for maximizing the amount of condensed water. This solution is applied to a system with a desiccant wheel dehumidifier and a dew point cooler, termed...... desiccant dew-point cooling system, for demonstrating its function and applicability. Simulations are carried out for varying outdoor conditions under constant supply conditions. The results show that the system is independent of external water supply for the majority of simulated conditions. In comparison...... to the desiccant dew-point system without water recovery, the required regeneration temperature increases and the system thermal efficiency decreases....

  20. Post-processing in cardiovascular computed tomography. Performance of a client server solution versus a stand-alone solution; Bildnachverarbeitung in der kardiovaskulaeren Computertomografie. Performance von Client-Server- versus Einzelplatzloesung

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, C.; Foldyna, B.; Andres, C.; Grothoff, M.; Nitzsche, S.; Gutberlet, M.; Lehmkuhl, L. [Leipzig Univ. - Herzzentrum (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Boehmer-Lasthaus, S. [Siemens Healthcare Sector, Erlangen (Germany). Imaging and Therapy Div.

    2014-12-15

    Purpose: To compare the performance of server-based (CSS) versus stand-alone post-processing software (ES) for the evaluation of cardiovascular CT examinations (cvCT) and to determine the crucial steps. Data of 40 patients (20 patients for coronary artery evaluation and 20 patients prior to transcatheter aortic valve implantation [TAVI]) were evaluated by 5 radiologists with CSS and ES. Data acquisition was performed using a dual-source 128-row CT unit (SOMATOM Definition Flash, Siemens, Erlangen, Germany) and a 64-row CT unit (Brilliance 64, Philips, Hamburg, Germany). The following workflow was evaluated: Data loading, aorta and coronary segmentation, curved multiplanar reconstruction (cMPR) and 3 D volume rendering technique (3D-VRT), measuring of coronary artery stenosis and planimetry of the aortic annulus. The time requirement and subjective quality for the workflow were evaluated. The coronary arteries as well as the TAVI data could be evaluated significantly faster with CSS (5.5 ± 2.9 min and 8.2 ± 4.0 min, respectively) than with ES (13.9 ± 5.2 min and 15.2 ± 10.9 min, respectively, p = 0.01). Segmentation of the aorta (CSS: 1.9 ± 2.0 min, ES: 3.7 ± 3.3 min), generating cMPR of coronaries (CSS: 0.5 ± 0.2 min, ES: 5.1 ± 2.6 min), aorta and iliac vessels (CSS: 0.5 ± 0.4 min and 0.4 ± 0.4 min, respectively, ES: 1.6 ± 0.7 min and 2.8 ± 3 min, respectively) could be performed significantly faster with CSS than with ES with higher quality of cMPR, measuring of coronary stenosis and 3D-VRT (p < 0.05). Evaluation of cvCT can be accomplished significantly faster and better with CSS than with ES. The segmentation remains the most time-consuming workflow step, so optimization of segmentation algorithms could improve performance even further.

  1. [Application of a stand-alone interbody fusion cage based on a novel porous TiO2/glass composite. I. Implantation in the sheep cervical spine and radiological evaluation].

    Science.gov (United States)

    Korinth, M C; Hero, T; Mahnken, A H; Ragoss, C; Scherer, K

    2004-12-01

    Animals are becoming more and more common as in vitro and in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examination human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO/glass composite (Ecopore) or polymethyl-methacrylate (PMMA) after discectomy. First experience with the use of the new material and its influence on the primary stability after in vitro application were gained. After fusion of 10 sheep cervical spines in the levels C2/3 and C4/5 in each case with PMMA and with an Ecopore-cage, radiologic as well as computertomographic examinations were performed postoperatively and every 4 weeks during the following 2 and 4 months, respectively. Apart from establishing our animal model, we analysed the radiological changes and the degree of bony fusion of the operated segments during the course. In addition we performed measurements of the corresponding disc space heights (DSH) and intervertebral angles (IVA) for comparison among each other, during the course and with the initial values. Immediately after placement of both implants in the disc spaces the mean DSH and IVA increased (34.8% and 53.9%, respectively). During the following months DSH decreased to a greater extent in the Ecopore-segments than in the PMMA-segments, even to a value below the initial value (p>0.05). Similarly, the IVA decreased in both groups in the postoperative time lapse, but more distinct in the Ecopore-segments (pmodel of the sheep cervical spine. Distinct radiological changes regarding evident subsidence and detectable fusion of the segments, operated on with the new biomaterial, were seen. We demonstrated the

  2. OS Independent Mobile Solutions for Manufacturing Execution Systems

    Directory of Open Access Journals (Sweden)

    Heiko Meyer

    2013-12-01

    Full Text Available From the suppliers' perspective it is best to provide the user of a plant with a mobile solution in the form of perfectly matching Apps for the rolled-out manufacturing execution system. Due to the extremely short innovation cycle in the mobile phone development and not least because of the first iPhone generation launch in 2007 the mobile phone market completely changed over the past four years. Today, a large percentage of the sold devices can be classified as smart phones. The paper describes an easy and reliable way to develop OS independent mobile solutions for all common smartphones based on standard technologies.

  3. Generic Health Management: A System Engineering Process Handbook Overview and Process

    Science.gov (United States)

    Wilson, Moses Lee; Spruill, Jim; Hong, Yin Paw

    1995-01-01

    Health Management, a System Engineering Process, is one of those processes-techniques-and-technologies used to define, design, analyze, build, verify, and operate a system from the viewpoint of preventing, or minimizing, the effects of failure or degradation. It supports all ground and flight elements during manufacturing, refurbishment, integration, and operation through combined use of hardware, software, and personnel. This document will integrate Health Management Processes (six phases) into five phases in such a manner that it is never a stand alone task/effort which separately defines independent work functions.

  4. Independent engineering review of the Hanford Waste Vitrification System

    International Nuclear Information System (INIS)

    1991-10-01

    The Hanford Waste Vitrification Plant (HWVP) was initiated in June 1987. The HWVP is an essential element of the plan to end present interim storage practices for defense wastes and to provide for permanent disposal. The project start was justified, in part, on efficient technology and design information transfer from the prototype Defense Waste Processing Facility (DWPF). Development of other serial Hanford Waste Vitrification System (HWVS) elements, such as the waste retrieval system for the double-shell tanks (DSTs), and the pretreatment system to reduce the waste volume converted into glass, also was required to accomplish permanent waste disposal. In July 1991, at the time of this review, the HWVP was in the Title 2 design phase. The objective of this technical assessment is to determine whether the status of the technology development and engineering practice is sufficient to provide reasonable assurance that the HWVP and the balance of the HWVS system will operate in an efficient and cost-effective manner. The criteria used to facilitate a judgment of potential successful operation are: vitrification of high-level radioactive waste from specified DSTs on a reasonably continuous basis; and glass produced with physical and chemical properties formally acknowledge as being acceptable for disposal in a repository for high-level radioactive waste. The criteria were proposed specifically for the Independent Engineering Review to focus that assessment effort. They are not represented as the criteria by which the Department will judge the prudence of the Project. 78 refs., 10 figs., 12 tabs

  5. Experience-independent development of the hamster circadian visual system.

    Directory of Open Access Journals (Sweden)

    August Kampf-Lassin

    2011-04-01

    Full Text Available Experience-dependent functional plasticity is a hallmark of the primary visual system, but it is not known if analogous mechanisms govern development of the circadian visual system. Here we investigated molecular, anatomical, and behavioral consequences of complete monocular light deprivation during extended intervals of postnatal development in Syrian hamsters. Hamsters were raised in constant darkness and opaque contact lenses were applied shortly after eye opening and prior to the introduction of a light-dark cycle. In adulthood, previously-occluded eyes were challenged with visual stimuli. Whereas image-formation and motion-detection were markedly impaired by monocular occlusion, neither entrainment to a light-dark cycle, nor phase-resetting responses to shifts in the light-dark cycle were affected by prior monocular deprivation. Cholera toxin-b subunit fluorescent tract-tracing revealed that in monocularly-deprived hamsters the density of fibers projecting from the retina to the suprachiasmatic nucleus (SCN was comparable regardless of whether such fibers originated from occluded or exposed eyes. In addition, long-term monocular deprivation did not attenuate light-induced c-Fos expression in the SCN. Thus, in contrast to the thalamocortical projections of the primary visual system, retinohypothalamic projections terminating in the SCN develop into normal adult patterns and mediate circadian responses to light largely independent of light experience during development. The data identify a categorical difference in the requirement for light input during postnatal development between circadian and non-circadian visual systems.

  6. Independent engineering review of the Hanford Waste Vitrification System

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    The Hanford Waste Vitrification Plant (HWVP) was initiated in June 1987. The HWVP is an essential element of the plan to end present interim storage practices for defense wastes and to provide for permanent disposal. The project start was justified, in part, on efficient technology and design information transfer from the prototype Defense Waste Processing Facility (DWPF). Development of other serial Hanford Waste Vitrification System (HWVS) elements, such as the waste retrieval system for the double-shell tanks (DSTs), and the pretreatment system to reduce the waste volume converted into glass, also was required to accomplish permanent waste disposal. In July 1991, at the time of this review, the HWVP was in the Title 2 design phase. The objective of this technical assessment is to determine whether the status of the technology development and engineering practice is sufficient to provide reasonable assurance that the HWVP and the balance of the HWVS system will operate in an efficient and cost-effective manner. The criteria used to facilitate a judgment of potential successful operation are: vitrification of high-level radioactive waste from specified DSTs on a reasonably continuous basis; and glass produced with physical and chemical properties formally acknowledge as being acceptable for disposal in a repository for high-level radioactive waste. The criteria were proposed specifically for the Independent Engineering Review to focus that assessment effort. They are not represented as the criteria by which the Department will judge the prudence of the Project. 78 refs., 10 figs., 12 tabs.

  7. Towards functional specification independent of control system suppliers

    International Nuclear Information System (INIS)

    Galara, D.; Leret, E.

    1997-01-01

    For the next nuclear power plant generation, REP 2000, the Engineering and construction Division (ED) and the Research and development Division (R and D) of Electricite de France are working together in the field of Instrumentation and Control (I and C) to improve its engineering method and tools. This method and these tools are defined on the basis of the experience feedback from the N4 nuclear power plant generation and the current information technology, to improve engineering competitiveness and quality of control applications. We intend to decouple the I and C processing from the I and C Human Machine Interface (HMI), because methods and tools are different. In this paper, we only focus on method and tools for I and C processing. We define the I and C processing life cycle into three phases. The first phase is the specification of the control application processing, the product of which is called Functional Requirement Diagrams (FRDs). The second phase is the design of the I and C system. This phase is subdivided into two steps. The step 1 is the distribution of the FRDs into an I and C architecture. The step 2 is the allocation of resources of the I and C system, to support the distributed FRDs. The third phase is the implementation of the distributed FRDs into I and C equipment. The aim of the Engineering Division is to achieve formal FRDs, independent of I and C suppliers. This allows a large improvement for the quality of the specification and the dimensioning of the I and C system before calls for tenders. For the specification phase, studies are almost completed. For the design and the implementation phases, studies and experiments are in progress with European I and C system suppliers. As a conclusion, we present the interest of EDF for standards and especially IEC 1131 improvements. (author). 5 figs

  8. Towards functional specification independent of control system suppliers

    Energy Technology Data Exchange (ETDEWEB)

    Galara, D; Leret, E [Electricite de France, Research and Development Div., Power Plant Control Branch, Chatou (France)

    1997-07-01

    For the next nuclear power plant generation, REP 2000, the Engineering and construction Division (ED) and the Research and development Division (R and D) of Electricite de France are working together in the field of Instrumentation and Control (I and C) to improve its engineering method and tools. This method and these tools are defined on the basis of the experience feedback from the N4 nuclear power plant generation and the current information technology, to improve engineering competitiveness and quality of control applications. We intend to decouple the I and C processing from the I and C Human Machine Interface (HMI), because methods and tools are different. In this paper, we only focus on method and tools for I and C processing. We define the I and C processing life cycle into three phases. The first phase is the specification of the control application processing, the product of which is called Functional Requirement Diagrams (FRDs). The second phase is the design of the I and C system. This phase is subdivided into two steps. The step 1 is the distribution of the FRDs into an I and C architecture. The step 2 is the allocation of resources of the I and C system, to support the distributed FRDs. The third phase is the implementation of the distributed FRDs into I and C equipment. The aim of the Engineering Division is to achieve formal FRDs, independent of I and C suppliers. This allows a large improvement for the quality of the specification and the dimensioning of the I and C system before calls for tenders. For the specification phase, studies are almost completed. For the design and the implementation phases, studies and experiments are in progress with European I and C system suppliers. As a conclusion, we present the interest of EDF for standards and especially IEC 1131 improvements. (author). 5 figs.

  9. A Text-Independent Speaker Authentication System for Mobile Devices

    Directory of Open Access Journals (Sweden)

    Florentin Thullier

    2017-09-01

    Full Text Available This paper presents a text independent speaker authentication method adapted to mobile devices. Special attention was placed on delivering a fully operational application, which admits a sufficient reliability level and an efficient functioning. To this end, we have excluded the need for any network communication. Hence, we opted for the completion of both the training and the identification processes directly on the mobile device through the extraction of linear prediction cepstral coefficients and the naive Bayes algorithm as the classifier. Furthermore, the authentication decision is enhanced to overcome misidentification through access privileges that the user should attribute to each application beforehand. To evaluate the proposed authentication system, eleven participants were involved in the experiment, conducted in quiet and noisy environments. Public speech corpora were also employed to compare this implementation to existing methods. Results were efficient regarding mobile resources’ consumption. The overall classification performance obtained was accurate with a small number of samples. Then, it appeared that our authentication system might be used as a first security layer, but also as part of a multilayer authentication, or as a fall-back mechanism.

  10. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 123; Issue 8 ... (SF) receivers has the advantages of stand-alone, absolute positioning and cost efficiency. ... College of Informatics, South China Agricultural University, Guangzhou, ...

  11. Alternative route of process modification for biofuel production by embedding the Fischer–Tropsch plant in existing stand-alone power plant (10 MW) based on biomass gasification – Part I: A conceptual modeling and simulation approach (a case study in Thailand)

    International Nuclear Information System (INIS)

    Hunpinyo, Piyapong; Cheali, Peam; Narataruksa, Phavanee; Tungkamani, Sabaithip; Chollacoop, Nuwong

    2014-01-01

    Graphical abstract: SynBiofuel production through existing gasification plants in Thailand, using waste agricultural biomass as raw material, was studied. The process design was initiated conceptually in the areas of gas phase reaction system via Fischer-Tropsch (FT) synthesis. The development of FT configurations on syngas conversion to transportation fuels (e.g., diesel range) was investigated. In order to develop a techno-economic assessment, the three different capacities corresponding to 1 MW, 2 MW and 3 MW based on thermal input of syngas were evaluated. Once-through FT concept was proposed in which the unconverted syngas was combusted with air in an externally fired gas turbine (EFGT) to produce surplus electricity. The results of process simulation were discussed open-mindedly including the overall plant design and energy efficiency. Preliminary economics, and some site specific situations under which additional capital cost savings on existing infrastructure was realized. - Highlights: • Experimental results were used and integrated with a reactor model for SynBiofuel. • Process simulation with the lumped reaction rate was used to achieve accurate results. • Process simulation was performed using ASPEN Plus to design FT configurations. • Maximum energy FT efficiency was approximately 37%. • Economic potential was computed by ROI and PBP resulting in the attractive solutions. - Abstract: The utilization of syngas shows a highly potential to improve the economic potential of the stand-alone power unit-based gasification plants as well as enhancing the growing demand of transportation fuels. The thermochemical conversion of biomass via gasification to heat and power generations from the earlier study is further enhanced by integrating Fischer–Tropsch (FT) synthesis with the existing gasification pilot scale studied previously. To support the potential and perspectives in major economies due to scaling up in developing countries such as Thailand

  12. Modeling of Pem Fuel Cell Systems Including Controls and Reforming Effects for Hybrid Automotive Applications

    National Research Council Canada - National Science Library

    Boettner, Daisie

    2001-01-01

    .... This study develops models for a stand-alone Proton Exchange Membrane (PEM) fuel cell stack, a direct-hydrogen fuel cell system including auxiliaries, and a methanol reforming fuel cell system for integration into a vehicle performance simulator...

  13. Efficient Device-Independent Entanglement Detection for Multipartite Systems

    Science.gov (United States)

    Baccari, F.; Cavalcanti, D.; Wittek, P.; Acín, A.

    2017-04-01

    Entanglement is one of the most studied properties of quantum mechanics for its application in quantum information protocols. Nevertheless, detecting the presence of entanglement in large multipartite states continues to be a great challenge both from the theoretical and the experimental point of view. Most of the known methods either have computational costs that scale inefficiently with the number of particles or require more information on the state than what is attainable in everyday experiments. We introduce a new technique for entanglement detection that provides several important advantages in these respects. First, it scales efficiently with the number of particles, thus allowing for application to systems composed by up to few tens of particles. Second, it needs only the knowledge of a subset of all possible measurements on the state, therefore being apt for experimental implementation. Moreover, since it is based on the detection of nonlocality, our method is device independent. We report several examples of its implementation for well-known multipartite states, showing that the introduced technique has a promising range of applications.

  14. 78 FR 77447 - California Wind Energy Association, First Solar, Inc. v. California Independent System Operator...

    Science.gov (United States)

    2013-12-23

    ... Energy Association, First Solar, Inc. v. California Independent System Operator Corporation, Southern...), California Wind Energy Association and First Solar, Inc. (collectively, Complainants) filed a formal complaint against the California Independent System Operator Corporation (CAISO) and Southern California...

  15. [Independent ethics committees for clinical research in Argentina. An evaluation and a system to guarantee their independence].

    Science.gov (United States)

    Gonorazky, Sergio E

    2008-01-01

    The Administración Nacional de Medicamentos, Alimentos y Tecnología Médica de la República Argentina (ANMAT) requires that an independent ethics committee of sponsors and/or researchers must previously evaluate and approve all the new pharmacological research protocols carried out on human beings. However, due to the lucrative nature of the evaluation, and because the selection of the Independent Ethics Committee is carried out by the sponsors and/or researchers, the assumed autonomy of the former can be reduced to merely a relationship of "service provider-customer". The Institutional Review Board of the Mar del Plata s Community Hospital has evaluated, between 2005 and 2006, thirty three research protocols (with their corresponding information sheets for patients and informed consent forms) previously approved by a non-institutional Independent Ethics Committee. The median number of objections made by the Institutional Review Board, which prompted the previously mentioned protocols to be modified in order to be approved, was of three per protocol. In other words, the accreditation of an Independent Ethics Committee requires a system that guarantees actual independence from the sponsors and/or researchers, as well as management control mechanisms that may lead them into an eventual loss of accreditation. Several measures are proposed in order to correct the deficiencies of the present system.

  16. A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up.

    Science.gov (United States)

    Chen, Yuqiao; Lü, Guohua; Wang, Bing; Li, Lei; Kuang, Lei

    2016-07-01

    To evaluate the clinical efficacy and radiological outcomes of anterior cervical discectomy and fusion (ACDF) using self-locking polyetheretherketone (PEEK) cages for treatment of three-level cervical degenerative spondylopathy. Twenty-eight patients underwent three-level ACDF using self-locking stand-alone PEEK cages (group A), and 26 patients underwent three-level ACDF using cages and plate fixation (group B) were reviewed retrospectively. Clinical efficacy was evaluated by pre- and post-operative Japanese Orthopedic Association (JOA) scores and Neck Disability Index (NDI). The operation time, blood loss, surgical results according to Odom's criteria and post-operative dysphagia status were also recorded. Radiological outcomes including fusion, cervical Cobb's lordosis, fused segment angle, disc height, and cage subsidence were assessed. Clinical outcome measures such as dysphagia and fusion rate and the results of surgery evaluated according to Odom's criteria were not statistically significant (P > 0.05) between groups. The operation time was shorter and blood loss was less in group A (P  0.05). Post-operative cage subsidence, the loss of disc height, cervical lordosis and the fused segment angle were relatively higher in group A than group B (P < 0.05). ACDF using self-locking stand-alone cages showed similar clinical results as compared to ACDF using cages and plate fixation for the treatment of three-level cervical degenerative spondylopathy. However, potential long-term problems such as cage subsidence, loss of cervical lordosis and fused segment angle post-operatively were shown to be associated with patients who underwent ACDF using self-locking stand-alone cages.

  17. An XML-Based Knowledge Management System of Port Information for U.S. Coast Guard Cutters

    National Research Council Canada - National Science Library

    Stewart, Jeffrey

    2003-01-01

    .... The system uses XML technologies in server/client and stand alone environments. With a web browser, the user views and navigates the system's content from a downloaded file collection or from a centralized data source via a network connection...

  18. Performance of small-scale photovoltaic systems and their potential for rural electrification in Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Stutenbaeumer, Ulrich; Negash, Tesfaye; Abdi, Amensisa [Addis Ababa Univ., Dept. of Physics, Addis Ababa (Ethiopia)

    1999-09-01

    The performance of small-scale stand-alone photovoltaic systems is tested under the climatic conditions of Addis Ababa, Ethiopia. With climatic data obtained at a station in the Rift Valley, the photovoltaic systems performance is estimated for those climatic conditions. The economics of small-scale stand-alone photovoltaic system applications under Ethiopian conditions are analysed. The potential of photovoltaics for the rural electrification of Ethiopia is discussed. (Author)

  19. Hybrid synchronization of two independent chaotic systems on ...

    Indian Academy of Sciences (India)

    Keywords. Hybrid synchronization; complex network; information source; chaotic system. ... encryption and decryption through synchronization. However, the ... Certainly, if the two systems are different, the security would be improved. How.

  20. COMBINING INDEPENDENT VISUALIZATION AND TRACKING SYSTEMS FOR AUGMENTED REALITY

    Directory of Open Access Journals (Sweden)

    P. Hübner

    2018-05-01

    Full Text Available The basic requirement for the successful deployment of a mobile augmented reality application is a reliable tracking system with high accuracy. Recently, a helmet-based inside-out tracking system which meets this demand has been proposed for self-localization in buildings. To realize an augmented reality application based on this tracking system, a display has to be added for visualization purposes. Therefore, the relative pose of this visualization platform with respect to the helmet has to be tracked. In the case of hand-held visualization platforms like smartphones or tablets, this can be achieved by means of image-based tracking methods like marker-based or model-based tracking. In this paper, we present two marker-based methods for tracking the relative pose between the helmet-based tracking system and a tablet-based visualization system. Both methods were implemented and comparatively evaluated in terms of tracking accuracy. Our results show that mobile inside-out tracking systems without integrated displays can easily be supplemented with a hand-held tablet as visualization device for augmented reality purposes.

  1. Independent School Success Challenging the Danish Public School System

    Science.gov (United States)

    Ringsmose, Charlotte

    2013-01-01

    Denmark has had a long history of placing a high priority on education and public schooling. It is a declared goal of the Danish welfare system to provide comprehensive schooling, where children from different socioeconomic backgrounds can go to school together and have the same opportunities through education. It is also a declared goal for…

  2. Autonomous photovoltaic lighting system

    OpenAIRE

    Hafez, Ahmed A. A.; Montesinos Miracle, Daniel; Sudrià Andreu, Antoni

    2012-01-01

    This paper introduces a comparison between the conventional and Photovoltaic (PV) lighting systems. A simple sizing procedure for a PV stand-alone system was advised. The paper also proposes a novel PV lighting system. The proposed system is simple, compact and reliable. The system operation was investigated by thoroughly mathematical and simulation work.

  3. Alternative route of process modification for biofuel production by embedding the Fischer-Tropsch plant in existing stand-alone power plant (10 MW) based on biomass gasification - Part I: A conceptual modeling and simulation approach (a case study in Thailand)

    DEFF Research Database (Denmark)

    Hunpinyo, Piyapong; Cheali, Peam; Narataruksa, Phavanee

    2014-01-01

    a base case process model coupled with techno-economic evaluation for the FT synthesis. In particular, the FT process configurations are designed and assessed using current kinetic laboratory data by our research group for modeling specific reactions in PFR reactor. The calculation of equipment sizing......The utilization of syngas shows a highly potential to improve the economic potential of the stand-alone power unit-based gasification plants as well as enhancing the growing demand of transportation fuels. The thermochemical conversion of biomass via gasification to heat and power generations from...... incurred several major unit operations is performed for once-through mode (no recycles of unconverted syngas) with electricity co-production. This study provides a detailed base-case model for the synthesis with the capacities of 1, 2 and 3 MW of syngas technology sharing and the comparison between...

  4. Energy independent uniformity improvement for gamma camera systems

    International Nuclear Information System (INIS)

    Lange, K.

    1979-01-01

    In a gamma camera system having an array of photomultiplier tubes for detecting scintillation events and preamplifiers connecting each tube to a weighting resistor matrix for determining the position coordinates of the events, means are provided for summing the signals from all photomultipliers to obtain the total energy of each event. In one embodiment, at least two different percentages of the summed voltage are developed and used to change the gain of the preamplifiers as a function of total energy when energies exceed specific levels to thereby obtain more accurate correspondence between the true coordinates of the event and its coordinates in a display

  5. Molecular Mechanics and Dynamics Characterization of an "in silico" Mutated Protein: A Stand-Alone Lab Module or Support Activity for "in vivo" and "in vitro" Analyses of Targeted Proteins

    Science.gov (United States)

    Chiang, Harry; Robinson, Lucy C.; Brame, Cynthia J.; Messina, Troy C.

    2013-01-01

    Over the past 20 years, the biological sciences have increasingly incorporated chemistry, physics, computer science, and mathematics to aid in the development and use of mathematical models. Such combined approaches have been used to address problems from protein structure-function relationships to the workings of complex biological systems.…

  6. Mass independent kinetic energy reducing inlet system for vacuum environment

    Science.gov (United States)

    Reilly, Peter T. A. [Knoxville, TN

    2010-12-14

    A particle inlet system comprises a first chamber having a limiting orifice for an incoming gas stream and a micrometer controlled expansion slit. Lateral components of the momentum of the particles are substantially cancelled due to symmetry of the configuration once the laminar flow converges at the expansion slit. The particles and flow into a second chamber, which is maintained at a lower pressure than the first chamber, and then moves into a third chamber including multipole guides for electromagnetically confining the particle. The vertical momentum of the particles descending through the center of the third chamber is minimized as an upward stream of gases reduces the downward momentum of the particles. The translational kinetic energy of the particles is near-zero irrespective of the mass of the particles at an exit opening of the third chamber, which may be advantageously employed to provide enhanced mass resolution in mass spectrometry.

  7. Enabling vendor independent photoacoustic imaging systems with asynchronous laser source

    Science.gov (United States)

    Wu, Yixuan; Zhang, Haichong K.; Boctor, Emad M.

    2018-02-01

    Channel data acquisition, and synchronization between laser excitation and PA signal acquisition, are two fundamental hardware requirements for photoacoustic (PA) imaging. Unfortunately, however, neither is equipped by most clinical ultrasound scanners. Therefore, less economical specialized research platforms are used in general, which hinders a smooth clinical transition of PA imaging. In previous studies, we have proposed an algorithm to achieve PA imaging using ultrasound post-beamformed (USPB) RF data instead of channel data. This work focuses on enabling clinical ultrasound scanners to implement PA imaging, without requiring synchronization between the laser excitation and PA signal acquisition. Laser synchronization is inherently consisted of two aspects: frequency and phase information. We synchronize without communicating the laser and the ultrasound scanner by investigating USPB images of a point-target phantom in two steps. First, frequency information is estimated by solving a nonlinear optimization problem, under the assumption that the segmented wave-front can only be beamformed into a single spot when synchronization is achieved. Second, after making frequencies of two systems identical, phase delay is estimated by optimizing the image quality while varying phase value. The proposed method is validated through simulation, by manually adding both frequency and phase errors, then applying the proposed algorithm to correct errors and reconstruct PA images. Compared with the ground truth, simulation results indicate that the remaining errors in frequency correction and phase correction are 0.28% and 2.34%, respectively, which affirm the potential of overcoming hardware barriers on PA imaging through software solution.

  8. Reform of Kosovo Tax System after independence and its key functions

    OpenAIRE

    Dr.Sc. Bedri Peci

    2013-01-01

    In this paper we have analyzed the initial circumstances which characterize tax system in Kosovo after independence. After the Declaration of Independence, it is of the paramount importance that Kosovo has undergone through a reform of policy and tax system by exploring more seriously the economic functions. However, policy and tax system of Kosovo should be more in function of economic development by achieving equilibrium between direct and indirect taxes, increasing efficiency of public ...

  9. Development of Network Devices Supporting Communication Independence In NPP I and C Systems

    International Nuclear Information System (INIS)

    Jeong, K.-I.; Suh, Y.S.; Park, G.-O.; Park, J.-Y.

    2013-06-01

    As advanced digital I and C systems of nuclear power plants or research reactors are being introduced to replace analog systems, a data communication network is necessary for data exchanges between I and C systems of nuclear power plants or research reactors. Data communication network technology may have significant impact on I and C systems. As the safety I and C system is composed of redundant channels to enhance the performance of the safety functions and data communication system is used to transmit the data generated by the digital I and C systems, communication independence is required to mitigate the risk of safety I and C system failure. Therefore this paper mainly discusses the issues related to the communication independence and the current status of network devices we designed, developed, and validated to satisfy the requirements of function, performance, and communication independence. (authors)

  10. Radon Monitoring in Army Stand-Alone Housing Units

    Science.gov (United States)

    1990-04-01

    damage lung tissue and lead I to increased risk of developing lang cancer . Your risk of developing lung cancer from exposure to radon depends upon the...of developing lung cancer than exposure to a significantly elevated level for a short time. In general, your risk increases as the level of radon and...000mm 0Mmm *000 OOO 0 0w 0 0 000 -0-0 *4 0 880 mama 0 0000000000 000 000Eca ( el cN) 00 9 ’ qqO .00 1(10 0 -U M w co SEE wSS SEES NSEwESO m v MM O v mm

  11. Basic Stand Alone Medicare Claims Public Use Files

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS is committed to increasing access to its Medicare claims data through the release of de-identified data files available for public use. They contain...

  12. The yeast stands alone: the future of protein biologic production.

    Science.gov (United States)

    Love, Kerry R; Dalvie, Neil C; Love, J Christopher

    2017-12-22

    Yeasts are promising alternative hosts for the manufacturing of recombinant protein therapeutics because they simply and efficiently meet needs for both platform and small-market drugs. Fast accumulation of biomass and low-cost media reduce the cost-of-goods when using yeast, which in turn can enable agile, small-volume manufacturing facilities. Small, tractable yeast genomes are amenable to rapid process development, facilitating strain and product quality by design. Specifically, Pichia pastoris is becoming a widely accepted yeast for biopharmaceutical manufacturing in much of the world owing to a clean secreted product and the rapidly expanding understanding of its cell biology as a host organism. We advocate for a near term partnership spanning industry and academia to promote open source, timely development of yeast hosts. Copyright © 2017. Published by Elsevier Ltd.

  13. Basic Stand Alone Medicare Prescription Drug Events PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This is a Public Use File for Prescription Drug Events drawn from the 2008 Beneficiary Summary File of Medicare beneficiaries enrolled during the calendar year 2008,...

  14. Constraining lidar stand-alone retrievals with lunar photometry measurements

    Science.gov (United States)

    Ortiz-Amezcua, Pablo; Luis Guerrero-Rascado, Juan; Antonio Benavent-Oltra, Jose; Román, Roberto; Böckmann, Christine; Alados-Arboledas, Lucas

    2018-04-01

    This study combines atmospheric optical information measured with lidar and nocturnal photometers in order to find configurations that allow for the retrieval of particle microphysical properties without "3+2" lidar setups. It has been carried out using data measured at the EARLINET Granada station during the experimental campaign SLOPE in the framework of ACTRIS-2 project.

  15. 78 FR 53450 - Centralized Capacity Markets in Regional Transmission Organizations and Independent System...

    Science.gov (United States)

    2013-08-29

    ... opportunity for each of the eastern Regional Transmission Organizations (RTOs)/Independent System Operators... PJM. The report summarizes the approaches taken by each of these RTOs/ISOs with respect to these...

  16. Camera System MTF: combining optic with detector

    Science.gov (United States)

    Andersen, Torben B.; Granger, Zachary A.

    2017-08-01

    MTF is one of the most common metrics used to quantify the resolving power of an optical component. Extensive literature is dedicated to describing methods to calculate the Modulation Transfer Function (MTF) for stand-alone optical components such as a camera lens or telescope, and some literature addresses approaches to determine an MTF for combination of an optic with a detector. The formulations pertaining to a combined electro-optical system MTF are mostly based on theory, and assumptions that detector MTF is described only by the pixel pitch which does not account for wavelength dependencies. When working with real hardware, detectors are often characterized by testing MTF at discrete wavelengths. This paper presents a method to simplify the calculation of a polychromatic system MTF when it is permissible to consider the detector MTF to be independent of wavelength.

  17. TULUNGAN: A Consensus-Independent Reputation System for Collaborative Web Filtering Systems

    Directory of Open Access Journals (Sweden)

    Alexis V. Pantola

    2011-12-01

    Full Text Available Web filtering systems allow or prohibit access to websites based on categories (e.g., pornography,violence, sports, etc.. Categorization of websites can be done automatically or manually. Automaticcategorization is prone to under- and over-blocking. On the other hand, manual approach is typicallyperformed by a limited number of people making it not scalable.Collaborative web filtering systems, a variation of manual categorization, allow anyone to categorizewebsites in order to determine which domain these sites belong (e.g., pornography, violence, sports,etc.. This attempts to solve the scalability issue of the typical manual method.The approach offered by collaborative web filtering relies heavily on the contribution of users in orderto make the system scalable and less prone to errors. However, its success is greatly dependent on usercooperation. To promote cooperation, reputation system can be used in web filtering.A previous study called Rater-Rating promotes cooperation and explores the use of a user-drivenreputation system that measures both the contributor and rater reputation of users of a collaborative websystem. However, Rater-Rating is consensus dependent. If the number of malicious users are more thantheir good counterparts, the reputation system can be defeated. In other words, the system canmistakenly give malicious users a high reputation value.This study discusses a reputation system called Tulungan that is consensus-independent. It can detectthe presence of malicious users even if the number of their good counterparts are fewer. A simulationresult that compares the effectiveness of Tulungan relative to Rater-Rating is presented in this paper.The simulation shows that Tulungan is still effective even with 25% good users while Rater-Ratingrequires at least 50% good users to be effective.

  18. Tools and methods for implementing the control systems on the Mirror Fusion Test Facility

    International Nuclear Information System (INIS)

    Minor, E.G.; Labiak, W.G.

    1981-01-01

    Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which were developed to carry out this plan will be described. Our experiences with bringing up subsystems containing up to 900 separate channels of control and status will also be described

  19. A consideration about major business control system for independent administrative institution

    International Nuclear Information System (INIS)

    Abe, Shinya; Nakata, Yutaka; Iitsuka, Tomoaki; Yamagishi, Kojiro

    2003-10-01

    Japanese government is carrying out the administrative reform aiming to promote decentralization of authority, to magnify the field of private sectors, etc. in order to corresponds appropriately to matured economy, internationalized market, etc. As one of the reforms, Japanese government decided that JAERI and JNC would unite into an independent administrative agency. The aims of the independent administrative agency institution include realization of effective and transparent system and management. The aim of the present investigation is to be useful for the new agency to develop a major business control system, which manages financial affairs and accounts not only efficiently but also in correspondence with open information to the public and promoting research activities effectively. First of all, the authors examined Japanese laws and standards relating to the independent administrative agency. They investigated the financial affairs and accounts systems of the preceding independent administrative agencies for research and development and also the development trends of work-flow systems in private enterprises in Japan. They considered expected problems and solutions for developing and making use of the major business control system. On the basis of the above investigations, the authors revealed the total concept of the best major business control system of the new unified agency besides the necessary conditions of the system for an independent administrative agency. Additionally, the above mentioned laws and standards are collected in an appendix. (author)

  20. Phase Noise Effect on MIMO-OFDM Systems with Common and Independent Oscillators

    Directory of Open Access Journals (Sweden)

    Xiaoming Chen

    2017-01-01

    Full Text Available The effects of oscillator phase noises (PNs on multiple-input multiple-output (MIMO orthogonal frequency division multiplexing (OFDM systems are studied. It is shown that PNs of common oscillators at the transmitter and at the receiver have the same influence on the performance of (single-stream beamforming MIMO-OFDM systems, yet different influences on spatial multiplexing MIMO-OFDM systems with singular value decomposition (SVD based precoding/decoding. When each antenna is equipped with an independent oscillator, the PNs at the transmitter and at the receiver have different influences on beamforming MIMO-OFDM systems as well as spatial multiplexing MIMO-OFDM systems. Specifically, the PN effect on the transmitter (receiver can be alleviated by having more transmit (receive antennas for the case of independent oscillators. It is found that the independent oscillator case outperforms the common oscillator case in terms of error vector magnitude (EVM.

  1. Obedience to compliance programs and independence for electricity and natural gas system operators. 2009 report

    International Nuclear Information System (INIS)

    2009-12-01

    In France, system operators belong to groups that also conduct business in the energy sector, in fields governed by competition rules. They could therefore be tempted to use their privileged position to their group's benefit, which would disadvantage end consumers. Non-discriminatory access to electricity and gas transmission and distribution networks is at the core of the market opening to competition approach implemented by the European Union since the end of the 1990's. EU and national enactments in force highlight two tools to ensure nondiscrimination: compliance programmes and independence of system operators with regard to their parent companies. Firstly, compliance programs contain measures taken to ensure that discrimination is completely excluded and that their application is subject to appropriate monitoring. Secondly, system operator independence plays a part in preventing discrimination against competitors with other business activities (generation, supply, etc.) within the same group. In application of these enactments, every electricity or natural gas transmission or distribution system operator serving more than 100,000 customers provided CRE, the Energy Regulatory Commission, with their annual reports on the application of their compliance programs. This document is CRE's 2009 report about compliance programmes and independence of electricity and natural gas system operators. Its content can be summarized as follows: 1 - system operator independence serving consumers: Non-discriminatory access to networks is essential for the development of competitive markets, System operator compliance programs and independence act as a guarantee of nondiscrimination, The legal context in which these issues are addressed is set to change in the near future; 2 - A high level of obedience to compliance programs: The continued efforts of system operators prevent discrimination, CR E has assessed distribution system operators by means of a mystery

  2. Applicability of a desiccant dew-point cooling system independent of external water sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Kærn, Martin Ryhl

    2015-01-01

    The applicability of a technical solution for making desiccant cooling systems independent of external water sources is investigated. Water is produced by condensing the desorbed water vapour in a closed regeneration circuit. Desorbed water recovery is applied to a desiccant dew-point cooling...... system, which includes a desiccant wheel and a dew point cooler. The system is simulated during the summer period in the Mediterranean climate of Rome and it results completely independent of external water sources. The seasonal thermal COP drops 8% in comparison to the open regeneration circuit solution...

  3. Persons with Alzheimer's Disease Make Phone Calls Independently Using a Computer-Aided Telephone System

    Science.gov (United States)

    Perilli, Viviana; Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Cassano, Germana; Cordiano, Noemi; Pinto, Katia; Minervini, Mauro G.; Oliva, Doretta

    2012-01-01

    This study assessed whether four patients with a diagnosis of Alzheimer's disease could make independent phone calls via a computer-aided telephone system. The study was carried out according to a non-concurrent multiple baseline design across participants. All participants started with baseline during which the telephone system was not available,…

  4. 77 FR 52137 - Proposed Order and Request for Comment on a Petition From Certain Independent System Operators...

    Science.gov (United States)

    2012-08-28

    ...'') \\1\\ from certain regional transmission organizations (``RTOs'') and independent system operators...\\ Petitioners include three RTOs (Midwest Independent Transmission System Operator Inc. (``MISO''); ISO New...\\ Petitioners represent that the roles, responsibilities and services of ISOs and RTOs are substantially similar...

  5. A model-independent description of few-body system with strong interaction

    International Nuclear Information System (INIS)

    Simenog, I.V.

    1985-01-01

    In this contribution, the authors discuss the formulation of equations that provide model-independent description of systems of three and more nucleons irrespective of the details of the interaction, substantiate the approach, estimate the correction terms with respect to the force range, and give basic qualitative results obtained by means of the model-independent procedure. They consider three nucleons in the doublet state (spin S=I/2) taking into account only S-interaction. The elastic nd-scattering amplitude may be found from the model-independent equations that follow from the Faddeev equations in the short-range-force limit. They note that the solutions of several model-independent equations and basic results obtained with the use of this approach may serve both as a standard solution and starting point in the discussion of various conceptions concerning the details of nuclear interactions

  6. 28 CFR 700.31 - Exemption of the Office of Independent Counsel's systems of records-limited access.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Exemption of the Office of Independent Counsel's systems of records-limited access. 700.31 Section 700.31 Judicial Administration OFFICE OF INDEPENDENT COUNSEL PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION OF THE OFFICE OF INDEPENDENT COUNSEL Exemption of the Office of Independent...

  7. Preparation of a program for the independent verification of the brachytherapy planning systems calculations

    International Nuclear Information System (INIS)

    V Carmona, V.; Perez-Calatayud, J.; Lliso, F.; Richart Sancho, J.; Ballester, F.; Pujades-Claumarchirant, M.C.; Munoz, M.

    2010-01-01

    In this work a program is presented that independently checks for each patient the treatment planning system calculations in low dose rate, high dose rate and pulsed dose rate brachytherapy. The treatment planning system output text files are automatically loaded in this program in order to get the source coordinates, the desired calculation point coordinates and the dwell times when it is the case. The source strength and the reference dates are introduced by the user. The program allows implementing the recommendations about independent verification of the clinical brachytherapy dosimetry in a simple and accurate way, in few minutes. (Author).

  8. Complete modeling and software implementation of a virtual solar hydrogen hybrid system

    International Nuclear Information System (INIS)

    Pedrazzi, S.; Zini, G.; Tartarini, P.

    2010-01-01

    A complete mathematical model and software implementation of a solar hydrogen hybrid system has been developed and applied to real data. The mathematical model has been derived from sub-models taken from literature with appropriate modifications and improvements. The model has been implemented as a stand-alone virtual energy system in a model-based, multi-domain software environment. A test run has then been performed on typical residential user data-sets over a year-long period. Results show that the virtual hybrid system can bring about complete grid independence; in particular, hydrogen production balance is positive (+1.25 kg) after a year's operation with a system efficiency of 7%.

  9. Evolution of perturbed dynamical systems: analytical computation with time independent accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Gurzadyan, A.V. [Russian-Armenian (Slavonic) University, Department of Mathematics and Mathematical Modelling, Yerevan (Armenia); Kocharyan, A.A. [Monash University, School of Physics and Astronomy, Clayton (Australia)

    2016-12-15

    An analytical method for investigation of the evolution of dynamical systems with independent on time accuracy is developed for perturbed Hamiltonian systems. The error-free estimation using of computer algebra enables the application of the method to complex multi-dimensional Hamiltonian and dissipative systems. It also opens principal opportunities for the qualitative study of chaotic trajectories. The performance of the method is demonstrated on perturbed two-oscillator systems. It can be applied to various non-linear physical and astrophysical systems, e.g. to long-term planetary dynamics. (orig.)

  10. 75 FR 32458 - TC Ravenswood, LLC v. New York Independent System Operator, Inc.; Notice of Complaint

    Science.gov (United States)

    2010-06-08

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL10-70-000] TC Ravenswood... 385.206, TC Ravenswood, LLC (Complainant) filed a complaint against New York Independent System Operator, Inc. (NYISO) (Respondent), requesting FERC order the NYISO to reimburse TC Ravenswood, LLC, as...

  11. 75 FR 81264 - Critical Path Transmission, LLC; Clear Power, LLC; v. California Independent System Operator, Inc...

    Science.gov (United States)

    2010-12-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL11-11-000] Critical Path Transmission, LLC; Clear Power, LLC; v. California Independent System Operator, Inc.; Notice of Complaint... and 306 of the Federal Power Act, 16 U.S.C. 824e and 825e (2006), Critical Path Transmission, LLC and...

  12. Putting "The System" into a School Autonomy Reform: The Case of the Independent Public Schools Program

    Science.gov (United States)

    Gobby, Brad

    2016-01-01

    The Australian Federal and state governments have been introducing neoliberal reforms to the governance of their education systems for a number of decades. One of the most recent programs of reform is the Western Australian Independent Public Schools (IPS) initiative. Similar to decentralizing reforms around the world, the IPS program seeks…

  13. 77 FR 24192 - SIG Energy, LLLP v. California Independent System Operator Corporation; Notice of Complaint

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL12-55-000] SIG Energy, LLLP v. California Independent System Operator Corporation; Notice of Complaint Take notice that on.... 824(e) and 825(e), SIG Energy, LLLP (Complainant) filed a formal complaint against the California...

  14. 77 FR 24950 - Midwest Independent Transmission, System Operator, Inc.; Supplemental Notice of Technical Conference

    Science.gov (United States)

    2012-04-26

    ... Conference. The Midwest Independent Transmission System Operator, Inc. (MISO) and/or Potomac Economics, Inc... that is less than 50 percent of the applicable Reference Level. Provide a justification for this... committed? Please explain. b. Can units committed based on economics in the SCUC and SCED processes be...

  15. Efficiency Analysis of Independent and Centralized Heating Systems for Residential Buildings in Northern Italy

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2011-11-01

    Full Text Available The primary energy consumption in residential buildings is determined by the envelope thermal characteristics, air change, outside climatic data, users’ behaviour and the adopted heating system and its control. The new Italian regulations strongly suggest the installation of centralized boilers in renovated buildings with more than four apartments. This work aims to investigate the differences in primary energy consumption and efficiency among several independent and centralized heating systems installed in Northern Italy. The analysis is carried out through the following approach: firstly building heating loads are evaluated using the software TRNSYS® and, then, heating system performances are estimated through a simplified model based on the European Standard EN 15316. Several heating systems have been analyzed, evaluating: independent and centralized configurations, condensing and traditional boilers, radiator and radiant floor emitters and solar plant integration. The heating systems are applied to four buildings dating back to 2010, 2006, 1960s and 1930s. All the combinations of heating systems and buildings are analyzed in detail, evaluating efficiency and primary energy consumption. In most of the cases the choice between centralized and independent heating systems has minor effects on primary energy consumption, less than 3%: the introduction of condensing technology and the integration with solar heating plant can reduce energy consumption by 11% and 29%, respectively.

  16. Independent Orbiter Assessment (IOA): Assessment of the data processing system FMEA/CIL

    Science.gov (United States)

    Lowery, H. J.; Haufler, W. A.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Data Processing System (DPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison is documented for the Orbiter DPS hardware.

  17. Computing physical properties with quantum Monte Carlo methods with statistical fluctuations independent of system size.

    Science.gov (United States)

    Assaraf, Roland

    2014-12-01

    We show that the recently proposed correlated sampling without reweighting procedure extends the locality (asymptotic independence of the system size) of a physical property to the statistical fluctuations of its estimator. This makes the approach potentially vastly more efficient for computing space-localized properties in large systems compared with standard correlated methods. A proof is given for a large collection of noninteracting fragments. Calculations on hydrogen chains suggest that this behavior holds not only for systems displaying short-range correlations, but also for systems with long-range correlations.

  18. Independent measuring station for the GNEJS neutron spectrometer information and measurement system

    International Nuclear Information System (INIS)

    Gorokhov, I.S.; Laptev, A.B.; Marchenkov, V.V.; Tubol'tsev, Yu.V.; Fokin, E.Yu.; Shcherbakov, O.A.

    1984-01-01

    An independent measuring station (IMS) being a part of the information and measuring system of the neutron time-of-flight spectrometer is described. IMS represents the time (time-to-amplitude or time-to-angular) module analyzer assembled on the base of one or several CAMAC crates. The station permits to perform time measurements as well as the time measurements with amplitude weighing in an independent mode with subseqUent data transmission the central PDP-11/05 computer. The station processor unit is an independent controller. The software consists of the programming langUage of the controller from local terminal and programs ensuring measuring and shaping the spectra with their output on TV display devic. communication with the computer and dialogue with the operator

  19. Monitoring of good practices programs and independence for electricity and natural gas system operators. 2010 report

    International Nuclear Information System (INIS)

    2011-01-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 6. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2010. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2010 and audits carried out by the CRE services in these companies in 2010

  20. Monitoring of good practices programs and independence for electricity and natural gas system operators. Report 2012

    International Nuclear Information System (INIS)

    2013-09-01

    Electricity and natural gas transmission system operators (TSO) and distribution system operators (DSO) are regulated operators that provide public service functions for the benefit of the network users and the consumers they serve. Accordingly, European and French law requires that they be under independent and nondiscriminatory obligations. In particular, they must develop a good practices program which includes a range of measures to prevent the risk of discriminatory practices in network access. Pursuant to Article L.134-15 of the Energy Code, the Energy Regulatory Commission (CRE) is publishing this year its 8. annual report on the monitoring of good practices programs and independence for electricity and natural gas system operators for the year 2012. This report is based on analysis of the 'reports on the implementation of good practices programs' submitted to the CRE by the operators in late 2012 and audits carried out by the CRE services in these companies in 2012

  1. Multimodal and ubiquitous computing systems: supporting independent-living older users.

    Science.gov (United States)

    Perry, Mark; Dowdall, Alan; Lines, Lorna; Hone, Kate

    2004-09-01

    We document the rationale and design of a multimodal interface to a pervasive/ubiquitous computing system that supports independent living by older people in their own homes. The Millennium Home system involves fitting a resident's home with sensors--these sensors can be used to trigger sequences of interaction with the resident to warn them about dangerous events, or to check if they need external help. We draw lessons from the design process and conclude the paper with implications for the design of multimodal interfaces to ubiquitous systems developed for the elderly and in healthcare, as well as for more general ubiquitous computing applications.

  2. A cost-effective measurement-device-independent quantum key distribution system for quantum networks

    Science.gov (United States)

    Valivarthi, Raju; Zhou, Qiang; John, Caleb; Marsili, Francesco; Verma, Varun B.; Shaw, Matthew D.; Nam, Sae Woo; Oblak, Daniel; Tittel, Wolfgang

    2017-12-01

    We experimentally realize a measurement-device-independent quantum key distribution (MDI-QKD) system. It is based on cost-effective and commercially available hardware such as distributed feedback lasers and field-programmable gate arrays that enable time-bin qubit preparation and time-tagging, and active feedback systems that allow for compensation of time-varying properties of photons after transmission through deployed fiber. We examine the performance of our system, and conclude that its design does not compromise performance. Our demonstration paves the way for MDI-QKD-based quantum networks in star-type topology that extend over more than 100 km distance.

  3. Independent verification of monitor unit calculation for radiation treatment planning system.

    Science.gov (United States)

    Chen, Li; Chen, Li-Xin; Huang, Shao-Min; Sun, Wen-Zhao; Sun, Hong-Qiang; Deng, Xiao-Wu

    2010-02-01

    To ensure the accuracy of dose calculation for radiation treatment plans is an important part of quality assurance (QA) procedures for radiotherapy. This study evaluated the Monitor Units (MU) calculation accuracy of a third-party QA software and a 3-dimensional treatment planning system (3D TPS), to investigate the feasibility and reliability of independent verification for radiation treatment planning. Test plans in a homogenous phantom were designed with 3-D TPS, according to the International Atomic Energy Agency (IAEA) Technical Report No. 430, including open, blocked, wedge, and multileaf collimator (MLC) fields. Test plans were delivered and measured in the phantom. The delivered doses were input to the QA software and the independent calculated MUs were compared with delivery. All test plans were verified with independent calculation and phantom measurements separately, and the differences of the two kinds of verification were then compared. The deviation of the independent calculation to the measurements was (0.1 +/- 0.9)%, the biggest difference fell onto the plans that used block and wedge fields (2.0%). The mean MU difference between the TPS and the QA software was (0.6 +/- 1.0)%, ranging from -0.8% to 2.8%. The deviation in dose of the TPS calculation compared to the measurements was (-0.2 +/- 1.7)%, ranging from -3.9% to 2.9%. MU accuracy of the third-party QA software is clinically acceptable. Similar results were achieved with the independent calculations and the phantom measurements for all test plans. The tested independent calculation software can be used as an efficient tool for TPS plan verification.

  4. A new pneumatic suspension system with independent stiffness and ride height tuning capabilities

    Science.gov (United States)

    Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui

    2012-12-01

    This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.

  5. Microprocessor controlled dual parameter ADC system with a CAMAC interface

    Energy Technology Data Exchange (ETDEWEB)

    Perry, D G; Nickell, Jr, J D [Los Alamos Scientific Lab., NM (USA)

    1978-09-01

    Presented here is the design of a dual parameter ADC system which is controlled by a microprocessor and also interfaced to CAMAC. The system was designed to be mobile in that it may work wherever there is a CAMAC crate. In such cases where the CAMAC system is inoperative, the system may operate in a stand-alone mode.

  6. Definition of an automatic information retrieval system independent from the data base used

    International Nuclear Information System (INIS)

    Cunha, E.R.

    1983-04-01

    A bibliographic information retrieval system using data stored at the standardized interchange format ISO 2709 or ANSI Z39.2, is specified. A set of comands for interchange format manipulation wich allows the data access at the logical level, achieving the data independence, are used. A data base description language, a storage structure and data base manipulation comands are specified, using retrieval techniques which consider the applications needs. (Author) [pt

  7. Independent component analysis based digital signal processing in coherent optical fiber communication systems

    Science.gov (United States)

    Li, Xiang; Luo, Ming; Qiu, Ying; Alphones, Arokiaswami; Zhong, Wen-De; Yu, Changyuan; Yang, Qi

    2018-02-01

    In this paper, channel equalization techniques for coherent optical fiber transmission systems based on independent component analysis (ICA) are reviewed. The principle of ICA for blind source separation is introduced. The ICA based channel equalization after both single-mode fiber and few-mode fiber transmission for single-carrier and orthogonal frequency division multiplexing (OFDM) modulation formats are investigated, respectively. The performance comparisons with conventional channel equalization techniques are discussed.

  8. Effect of PVRC damping with independent support motion response spectrum analysis of piping systems

    International Nuclear Information System (INIS)

    Wang, Y.K.; Bezler, P.; Shteyngart, S.

    1986-01-01

    The Technical Committee for Piping Systems of the Pressure Vessel Research Committee (PVRC) has recommended new damping values to be used in the seismic analyses of piping systems in nuclear power plants. To evaluate the effects of coupling these recommendations with the use of independent support motion analyses methods, two sets of seismic analyses have been carried out for several piping systems. One set based on the use of uniform damping as specified in Regulatory Guide 1.61, the other based on the PVRC recommendations. In each set the analyses were performed using independent support motion time history and response spectrum methods as well as the envelope spectrum method. In the independent response spectrum analyses, 14 response estimates were in fact obtained by considering different combination procedures between the support group contributions and all sequences of combinations between support groups, modes and directions. For each analysis set, the response spectrum results were compared with time history estimates of those results. Comparison tables were then prepared depicting the percentage by which the response spectrum estimates exceeded the time history estimates. By comparing the result tables between both analysis sets, the impact of PVRC damping can be observed. Preliminary results show that the degree of exceedance of the response spectrum estimates based on PVRC damping is less than that based on uniform damping for the same piping problem. Expressed differently the results obtained if ISM methods are coupled with PVRC damping are not as conservative as those obtained using uniform damping

  9. Evolution of an Early Illness Warning System to Monitor Frail Elders in Independent Living

    Directory of Open Access Journals (Sweden)

    Gregory L. Alexander

    2011-01-01

    Full Text Available This paper describes the evolution of an early illness warning system used by an interdisciplinary team composed of clinicians and engineers in an independent living facility. The early illness warning system consists of algorithms which analyze resident activity patterns obtained from sensors embedded in residents' apartments. The engineers designed an automated reasoning system to generate clinically relevant alerts which are sent to clinicians when significant changes occur in the sensor data, for example declining activity levels. During January 2010 through July 2010, clinicians and engineers conducted weekly iterative review cycles of the early illness warning system to discuss concerns about the functionality of the warning system, to recommend solutions for the concerns, and to evaluate the implementation of the solutions. A total of 45 concerns were reviewed during this period. Iterative reviews resulted in greater efficiencies and satisfaction for clinician users who were monitoring elder activity patterns.

  10. A thermodynamic model of an air-independent IDI diesel engine system

    International Nuclear Information System (INIS)

    Zheng, M.; Reader, G.T.; Potter, I.J.; Gustafson, R.W.

    1992-01-01

    Synthetic atmosphere diesel (SAD) engines have been and are still being developed as air-independent power systems for use in naval and commercial underwater vehicles. Although the basic concept of such a system is relatively simple, its practical implementation is somewhat complicated and normally involves expensive and time consuming prototype development. If an analytical method existed which could be used to compare the overall performance of different configurations or highlight essential control aspects, system optimization could be attempted more readily and a close-to-optimum design produced prior to any subsequent practical development. Consequently, a thermodynamic simulation model has been formulated so that the performance and/or design of such systems can be investigated, and the effects of the various system variables can be identified. In this paper the development of the model and the associated experimental investigation is described

  11. Independent V and V for Safety Grade I and C System

    International Nuclear Information System (INIS)

    Lee, Jang Soo; Kwon, Kee Choon; Lee, Dong Young

    2010-08-01

    Through KNICS and Nu-Tech 2012, a MMIS(Man-Machine Interface System) package for nuclear plants was localized and is expected to be applied to SUN 1,2 plants. This study is aimed to support the application of the MMIS package including the following technologies that meet strengthened regulation requirements and enhanced utility's performance requirements to nuclear plants. - Dedication to real time operating system for safety-grade computers - V and V of the broadband communication network for safety information - Independent V and V for application of programmable logic controllers to nuclear plants - Development strategy for an integrated SW development tool for control devices

  12. Independent V and V for Safety Grade I and C System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang Soo; Kwon, Kee Choon; Lee, Dong Young [KAERI, Daejeon (Korea, Republic of)

    2010-08-15

    Through KNICS and Nu-Tech 2012, a MMIS(Man-Machine Interface System) package for nuclear plants was localized and is expected to be applied to SUN 1,2 plants. This study is aimed to support the application of the MMIS package including the following technologies that meet strengthened regulation requirements and enhanced utility's performance requirements to nuclear plants. - Dedication to real time operating system for safety-grade computers - V and V of the broadband communication network for safety information - Independent V and V for application of programmable logic controllers to nuclear plants - Development strategy for an integrated SW development tool for control devices

  13. An automatic speech recognition system with speaker-independent identification support

    Science.gov (United States)

    Caranica, Alexandru; Burileanu, Corneliu

    2015-02-01

    The novelty of this work relies on the application of an open source research software toolkit (CMU Sphinx) to train, build and evaluate a speech recognition system, with speaker-independent support, for voice-controlled hardware applications. Moreover, we propose to use the trained acoustic model to successfully decode offline voice commands on embedded hardware, such as an ARMv6 low-cost SoC, Raspberry PI. This type of single-board computer, mainly used for educational and research activities, can serve as a proof-of-concept software and hardware stack for low cost voice automation systems.

  14. Towards investigation of evolution of dynamical systems with independence of time accuracy: more classes of systems

    Science.gov (United States)

    Gurzadyan, V. G.; Kocharyan, A. A.

    2015-07-01

    The recently developed method (Paper 1) enabling one to investigate the evolution of dynamical systems with an accuracy not dependent on time is developed further. The classes of dynamical systems which can be studied by that method are much extended, now including systems that are: (1) non-Hamiltonian, conservative; (2) Hamiltonian with time-dependent perturbation; (3) non-conservative (with dissipation). These systems cover various types of N-body gravitating systems of astrophysical and cosmological interest, such as the orbital evolution of planets, minor planets, artificial satellites due to tidal, non-tidal perturbations and thermal thrust, evolving close binary stellar systems, and the dynamics of accretion disks.

  15. Operation reliability analysis of independent power plants of gas-transmission system distant production facilities

    Science.gov (United States)

    Piskunov, Maksim V.; Voytkov, Ivan S.; Vysokomornaya, Olga V.; Vysokomorny, Vladimir S.

    2015-01-01

    The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants) of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature) as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.

  16. Establishment of neurovascular congruency in the mouse whisker system by an independent patterning mechanism.

    Science.gov (United States)

    Oh, Won-Jong; Gu, Chenghua

    2013-10-16

    Nerves and vessels often run parallel to one another, a phenomenon that reflects their functional interdependency. Previous studies have suggested that neurovascular congruency in planar tissues such as skin is established through a "one-patterns-the-other" model, in which either the nervous system or the vascular system precedes developmentally and then instructs the other system to form using its established architecture as a template. Here, we find that, in tissues with complex three-dimensional structures such as the mouse whisker system, neurovascular congruency does not follow the previous model but rather is established via a mechanism in which nerves and vessels are patterned independently. Given the diversity of neurovascular structures in different tissues, guidance signals emanating from a central organizer in the specific target tissue may act as an important mechanism to establish neurovascular congruency patterns that facilitate unique target tissue function. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. A mobile console for local access to accelerator control systems.

    CERN Multimedia

    1981-01-01

    Microprocessors were installed as auxiliary crate controllers (ACCs) in the CAMAC interface of control systems for various accelerators. The same ACC was also at the hearth of a stand-alone system in the form of a mobile console. This was also used for local access to the control systems for tests and development work (Annual Report 1981, p. 80, Fig. 10).

  18. Central bank independence and inflation in Africa: The role of financial systems and institutional quality

    Directory of Open Access Journals (Sweden)

    Abel Mawuko Agoba

    2017-12-01

    Full Text Available The study examines the effects of financial systems and the quality of political institutions on the effectiveness of central bank independence in achieving lower inflation. Drawing from the fiscal theory of price level (FTPL and political economy of macroeconomic policy (PEMP literature; we estimate a panel regression model, using Two Stage Least Squares instrumental variables procedure, on a sample of 48 African countries over the period 1970–2012. The study finds that central bank independence-inflation nexus is dependent on the model, sample and estimation technique used. After accounting for various control variables and introducing inflation targeting as an additional explanatory variable, the study shows that, unlike in developed countries, CBI is not sufficient in achieving lower inflation in Africa and the developing world. However, common to developed, developing and African countries, is that, higher central bank independence is more effective in lowering inflation in the presence of high levels of banking sector development and institutional quality. The findings of the study also show that while stock market development enhances the effectiveness of CBI in developed and developing countries, it has no significant effect on CBI effectiveness in Africa.

  19. 78 FR 19879 - Final Order in Response to a Petition From Certain Independent System Operators and Regional...

    Science.gov (United States)

    2013-04-02

    ...'') \\1\\ from certain regional transmission organizations (``RTOs'') and independent system operators... include three RTOs (Midwest Independent Transmission System Operator, Inc. (``MISO''); ISO New England..., responsibilities and services of ISOs and RTOs are substantially similar.\\29\\ As described in the Proposed Order...

  20. A phenomenological and approximately flavour independent potential for quark-antiquark system

    International Nuclear Information System (INIS)

    Song Xiaotong.

    1988-08-01

    We proposed a phenomenological and flavour independent potential for quark-antiquark systems with equal or unequal masses. The potential has a Lorentz vector term motivated by empirical formula of leptonic width of vector meson at short distances and a Lorentz scalar part inspired by the result from lattice QCD responsible for quark confinement at large distances. Using this potential we calculated the energy levels, leptonic widths, radiative transition rates and hadronic decay rates of the (uu-bar), (dd-bar), (ss-bar), (cc-bar), (bb-bar) and (tt-bar) systems. The fine and hyperfine splittings of light and heavy quark-antiquark systems are also calculated. Most results agree fairly well with the experiment. (author). 46 refs, 5 figs, 13 tabs

  1. DEVELOPMENT OF RISK-BASED AND TECHNOLOGY-INDEPENDENT SAFETY CRITERIA FOR GENERATION IV SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    William E. Kastenberg; Edward Blandford; Lance Kim

    2009-03-31

    This project has developed quantitative safety goals for Generation IV (Gen IV) nuclear energy systems. These safety goals are risk based and technology independent. The foundations for a new approach to risk analysis has been developed, along with a new operational definition of risk. This project has furthered the current state-of-the-art by developing quantitative safety goals for both Gen IV reactors and for the overall Gen IV nuclear fuel cycle. The risk analysis approach developed will quantify performance measures, characterize uncertainty, and address a more comprehensive view of safety as it relates to the overall system. Appropriate safety criteria are necessary to manage risk in a prudent and cost-effective manner. This study is also important for government agencies responsible for managing, reviewing, and for approving advanced reactor systems because they are charged with assuring the health and safety of the public.

  2. DEVELOPMENT OF RISK-BASED AND TECHNOLOGY-INDEPENDENT SAFETY CRITERIA FOR GENERATION IV SYSTEMS

    International Nuclear Information System (INIS)

    Kastenberg, William E.; Blandford, Edward; Kim, Lance

    2009-01-01

    This project has developed quantitative safety goals for Generation IV (Gen IV) nuclear energy systems. These safety goals are risk based and technology independent. The foundations for a new approach to risk analysis has been developed, along with a new operational definition of risk. This project has furthered the current state-of-the-art by developing quantitative safety goals for both Gen IV reactors and for the overall Gen IV nuclear fuel cycle. The risk analysis approach developed will quantify performance measures, characterize uncertainty, and address a more comprehensive view of safety as it relates to the overall system. Appropriate safety criteria are necessary to manage risk in a prudent and cost-effective manner. This study is also important for government agencies responsible for managing, reviewing, and for approving advanced reactor systems because they are charged with assuring the health and safety of the public

  3. Independent bottlenecks characterize colonization of systemic compartments and gut lymphoid tissue by salmonella.

    Science.gov (United States)

    Lim, Chee Han; Voedisch, Sabrina; Wahl, Benjamin; Rouf, Syed Fazle; Geffers, Robert; Rhen, Mikael; Pabst, Oliver

    2014-07-01

    Vaccination represents an important instrument to control typhoid fever in humans and protects mice from lethal infection with mouse pathogenic serovars of Salmonella species. Mixed infections with tagged Salmonella can be used in combination with probabilistic models to describe the dynamics of the infection process. Here we used mixed oral infections with tagged Salmonella strains to identify bottlenecks in the infection process in naïve and vaccinated mice. We established a next generation sequencing based method to characterize the composition of tagged Salmonella strains which offers a fast and reliable method to characterise the composition of genome-tagged Salmonella strains. We show that initial colonization of Salmonella was distinguished by a non-Darwinian selection of few bacteria setting up the infection independently in gut associated lymphoid tissue and systemic compartments. Colonization of Peyer's patches fuels the sustained spread of bacteria into mesenteric lymph nodes via dendritic cells. In contrast, infection of liver and spleen originated from an independent pool of bacteria. Vaccination only moderately reduced invasion of Peyer's patches but potently uncoupled bacterial populations present in different systemic compartments. Our data indicate that vaccination differentially skews the capacity of Salmonella to colonize systemic and gut immune compartments and provide a framework for the further dissection of infection dynamics.

  4. Independent bottlenecks characterize colonization of systemic compartments and gut lymphoid tissue by salmonella.

    Directory of Open Access Journals (Sweden)

    Chee Han Lim

    2014-07-01

    Full Text Available Vaccination represents an important instrument to control typhoid fever in humans and protects mice from lethal infection with mouse pathogenic serovars of Salmonella species. Mixed infections with tagged Salmonella can be used in combination with probabilistic models to describe the dynamics of the infection process. Here we used mixed oral infections with tagged Salmonella strains to identify bottlenecks in the infection process in naïve and vaccinated mice. We established a next generation sequencing based method to characterize the composition of tagged Salmonella strains which offers a fast and reliable method to characterise the composition of genome-tagged Salmonella strains. We show that initial colonization of Salmonella was distinguished by a non-Darwinian selection of few bacteria setting up the infection independently in gut associated lymphoid tissue and systemic compartments. Colonization of Peyer's patches fuels the sustained spread of bacteria into mesenteric lymph nodes via dendritic cells. In contrast, infection of liver and spleen originated from an independent pool of bacteria. Vaccination only moderately reduced invasion of Peyer's patches but potently uncoupled bacterial populations present in different systemic compartments. Our data indicate that vaccination differentially skews the capacity of Salmonella to colonize systemic and gut immune compartments and provide a framework for the further dissection of infection dynamics.

  5. Asymptotic equivalence of neutron diffusion and transport in time-independent reactor systems

    International Nuclear Information System (INIS)

    Borysiewicz, M.; Mika, J.; Spiga, G.

    1982-01-01

    Presented in this paper is the asymptotic analysis of the time-independent neutron transport equation in the second-order variational formulation. The small parameter introduced into the equation is an estimate of the ratio of absorption and leakage to scattering in the system considered. When the ratio tends to zero, the weak solution to the transport problem tends to the weak solution of the diffusion problem, including properly defined boundary conditions. A formula for the diffusion coefficient different from that based on averaging the transport mean-free-path is derived

  6. Performance of different types of renewable power supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Al-Motawakel, M K [Sana' a Univ. (Republic of Yemen). Dept. of Physics; Abu-El-Eizz, H M; Awwad, Z [Zagazig Univ. (EG). Dept. of Physics

    1991-10-01

    In this paper we investigate the performance of a hybrid Photovoltaic (PV)-Wind generator power supply system operating under good and fair insolation and wind regimes. The effectiveness of such a hybrid system is measured by the Relative Sizing Parameter (RSP), Money Saving Parameter (MSP), and the Overall Reliability Parameter (ORP). Under specified weather conditions and for a nominal load demand, the RSP relates the product of the PV-modules and storage batteries involved in sizing the PV-Wind hybrid system to those of a stand alone PV-system sized to meet the same load. The MSP reports the difference between the total costs of a stand-alone PV power supply system and a hybrid PV-Wind power supply system, both sized to meet the same load, as a percentage of the total costs involved in supplying the load with a stand-alone PV power supply system only. The ORP compares the yearly average of the daily excess energy (positive difference between generated and consumed energy) of the hybrid system to that of the stand-alone PV power system. Based on this strategy we were able to develop a number of design diagrams which can be used in judging the benefits of utilizing hybrid PW-Wind generators on both economic and energy reliability grounds. (author).

  7. Modular program systems for scientific-technical programs

    International Nuclear Information System (INIS)

    Bennewitz, F.; Lembcke, R.

    1977-01-01

    In order to replace the numerous traditional stand alone codes, great modular data based systems were developed by KWU for the simulation of nuclear reactors. These latter systems exhibit a high degree of automatization and combine quality assurance with a high flexibility in special problems. On the other hand they show a greater mashine dependency. (orig.) [de

  8. Poliovirus trafficking toward central nervous system via human poliovirus receptor-dependent and -independent pathway.

    Directory of Open Access Journals (Sweden)

    Seii eOHKA

    2012-04-01

    Full Text Available In humans, paralytic poliomyelitis results from the invasion of the central nervous system by circulating poliovirus (PV via the blood-brain barrier (BBB. After the virus enters the central nervous system (CNS, it replicates in neurons, especially in motor neurons (MNs, inducing the cell death that causes paralytic poliomyelitis. Along with this route of dissemination, neural pathway has been reported in humans, monkeys, and PV-sensitive human PV receptor (hPVR/CD155-transgenic (Tg mice. We demonstrated that a fast retrograde axonal transport process is required for PV dissemination through the sciatic nerve of hPVR-Tg mice and that intramuscularly inoculated PV causes paralysis in a hPVR-dependent manner. We also showed that hPVR-independent axonal transport of PV exists in hPVR-Tg and non-Tg mice, indicating that several different pathways for PV axonal transport exist in these mice. Circulating PV after intravenous inoculation in mice cross the BBB at a high rate in a hPVR-independent manner. Recently, we identified transferrin receptor 1 (TfR1 of mouse brain capillary endothelial cells as a binding protein to PV, implicating that TfR1 is a possible receptor for PV to permeate the BBB.

  9. Independent Orbiter Assessment (IOA): Assessment of the backup flight system FMEA/CIL

    Science.gov (United States)

    Prust, E. E.; Ewell, J. J., Jr.; Hinsdale, L. W.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Backup Flight System (BFS) hardware, generating draft failure modes and Potential Critical Items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA Post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BFS hardware. The IOA product for the BFS analysis consisted of 29 failure mode worksheets that resulted in 21 Potential Critical Items (PCI) being identified. This product was originally compared with the proposed NASA BFS baseline and subsequently compared with the applicable Data Processing System (DPS), Electrical Power Distribution and Control (EPD and C), and Displays and Controls NASA CIL items. The comparisons determined if there were any results which had been found by the IOA but were not in the NASA baseline. The original assessment determined there were numerous failure modes and potential critical items in the IOA analysis that were not contained in the NASA BFS baseline. Conversely, the NASA baseline contained three FMEAs (IMU, ADTA, and Air Data Probe) for CIL items that were not identified in the IOA product.

  10. Independent Orbiter Assessment (IOA): Assessment of the orbiter main propulsion system FMEA/CIL, volume 1

    Science.gov (United States)

    Slaughter, B. C.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. The Orbiter MPS is composed of the Propellant Management Subsystem (PMS) consisting of the liquid oxygen (LO2) and liquid hydrogen (LH2) subsystems and the helium subsystem. The PMS is a system of manifolds, distribution lines, and valves by which the liquid propellants pass from the External Tank to the Space Shuttle Main Engine (SSME). The helium subsystem consists of a series of helium supply tanks and their associated regulators, control valves, and distribution lines. Volume 1 contains the MPS description, assessment results, ground rules and assumptions, and some of the IOA worksheets.

  11. A case independent approach on the impact of climate change effects on combined sewer system performance.

    Science.gov (United States)

    Kleidorfer, M; Möderl, M; Sitzenfrei, R; Urich, C; Rauch, W

    2009-01-01

    Design and construction of urban drainage systems has to be done in a predictive way, as the average lifespan of such investments is several decades. The design engineer has to predict many influencing factors and scenarios for future development of a system (e.g. change in land use, population, water consumption and infiltration measures). Furthermore, climate change can cause increased rain intensities which leads to an additional impact on drainage systems. In this paper we compare the behaviour of different performance indicators of combined sewer systems when taking into account long-term environmental change effects (change in rainfall characteristics, change in impervious area and change in dry weather flow). By using 250 virtual case studies this approach is--in principle--a Monte Carlo Simulation in which not only parameter values are varied but the entire system structure and layout is changed in each run. Hence, results are more general and case-independent. For example the consideration of an increase of rainfall intensities by 20% has the same effect as an increase of impervious area of +40%. Such an increase of rainfall intensities could be compensated by infiltration measures in current systems which lead to a reduction of impervious area by 30%.

  12. Development of a platform-independent receiver control system for SISIFOS

    Science.gov (United States)

    Lemke, Roland; Olberg, Michael

    1998-05-01

    Up to now receiver control software was a time consuming development usually written by receiver engineers who had mainly the hardware in mind. We are presenting a low-cost and very flexible system which uses a minimal interface to the real hardware, and which makes it easy to adapt to new receivers. Our system uses Tcl/Tk as a graphical user interface (GUI), SpecTcl as a GUI builder, Pgplot as plotting software, a simple query language (SQL) database for information storage and retrieval, Ethernet socket to socket communication and SCPI as a command control language. The complete system is in principal platform independent but for cost saving reasons we are using it actually on a PC486 running Linux 2.0.30, which is a copylefted Unix. The only hardware dependent part are the digital input/output boards, analog to digital and digital to analog convertors. In the case of the Linux PC we are using a device driver development kit to integrate the boards fully into the kernel of the operating system, which indeed makes them look like an ordinary device. The advantage of this system is firstly the low price and secondly the clear separation between the different software components which are available for many operating systems. If it is not possible, due to CPU performance limitations, to run all the software in a single machine,the SQL-database or the graphical user interface could be installed on separate computers.

  13. System modeling of an air-independent solid oxide fuel cell system for unmanned undersea vehicles

    Science.gov (United States)

    Burke, A. Alan; Carreiro, Louis G.

    To examine the feasibility of a solid oxide fuel cell (SOFC)-powered unmanned undersea vehicle (UUV), a system level analysis is presented that projects a possible integration of the SOFC stack, fuel steam reformer, fuel/oxidant storage and balance of plant components into a 21-in. diameter UUV platform. Heavy hydrocarbon fuel (dodecane) and liquid oxygen (LOX) are chosen as the preferred reactants. A maximum efficiency of 45% based on the lower heating value of dodecane was calculated for a system that provides 2.5 kW for 40 h. Heat sources and sinks have been coupled to show viable means of thermal management. The critical design issues involve proper recycling of exhaust steam from the fuel cell back into the reformer and effective use of the SOFC stack radiant heat for steam reformation of the hydrocarbon fuel.

  14. COMPUTER-BASED SYSTEMS OF PHYSICAL EXPERIMENT IN INDEPENDENT WORK OF STUDENTS OF TECHNICAL UNIVERSITY

    Directory of Open Access Journals (Sweden)

    Iryna Slipukhina

    2016-11-01

    Full Text Available Purpose: The self-study activity of students is an important form of educational process under the conditions of rapid changes of technologies. Ability and readiness of future engineers for independent education is one of their key competences. Investigation of modern methods of planning, organization and control of independent cognitive activity of students while studying physics as effective means of complex forming of their professional qualities is the object of the research. Methods: We analyse the curricula of some engineering specialities in leading technical universities, existent methods and forms of organization of students’ self-study, and own pedagogical experience. Results: Based on the theoretical analysis of existing methods of students’ self-study, it was found that a systematizing factor of appropriate educational technology is the problem focused cognitive tasks. They have to be implemented by application of the modern technological devices integrated with a computer-based experiment. We define the aim of individual or group laboratory works; the necessary theoretical and practical knowledge and skills of students are rationalized; timing and form of presentation of the results are clarified after individual and group consulting. The details of preparatory, searching-organizational, operational, and control stages in organization of students’ self-study with the use of computer oriented physical experiment are specified, these details differ depending on the didactic purpose, form of organization and students’ individuality. Discussion: The research theoretical aspect confirms the determining role of subject-subject cooperation in forming of competences of independent learning of the future engineers. Basic practical achievements of the research consist of improving methods of using of digital learning systems, creation of textbooks that promote consultative and guiding role for the educational process, working-out of

  15. The human endogenous circadian system causes greatest platelet activation during the biological morning independent of behaviors.

    Directory of Open Access Journals (Sweden)

    Frank A J L Scheer

    Full Text Available Platelets are involved in the thromboses that are central to myocardial infarctions and ischemic strokes. Such adverse cardiovascular events have day/night patterns with peaks in the morning (~9 AM, potentially related to endogenous circadian clock control of platelet activation. The objective was to test if the human endogenous circadian system influences (1 platelet function and (2 platelet response to standardized behavioral stressors. We also aimed to compare the magnitude of any effects on platelet function caused by the circadian system with that caused by varied standardized behavioral stressors, including mental arithmetic, passive postural tilt and mild cycling exercise.We studied 12 healthy adults (6 female who lived in individual laboratory suites in dim light for 240 h, with all behaviors scheduled on a 20-h recurring cycle to permit assessment of endogenous circadian function independent from environmental and behavioral effects including the sleep/wake cycle. Circadian phase was assessed from core body temperature. There were highly significant endogenous circadian rhythms in platelet surface activated glycoprotein (GP IIb-IIIa, GPIb and P-selectin (6-17% peak-trough amplitudes; p ≤ 0.01. These circadian peaks occurred at a circadian phase corresponding to 8-9 AM. Platelet count, ATP release, aggregability, and plasma epinephrine also had significant circadian rhythms but with later peaks (corresponding to 3-8 PM. The circadian effects on the platelet activation markers were always larger than that of any of the three behavioral stressors.These data demonstrate robust effects of the endogenous circadian system on platelet activation in humans--independent of the sleep/wake cycle, other behavioral influences and the environment. The 9 AM timing of the circadian peaks of the three platelet surface markers, including platelet surface activated GPIIb-IIIa, the final common pathway of platelet aggregation, suggests that endogenous

  16. What is the effect of optimum independent parameters on solar heating systems?

    International Nuclear Information System (INIS)

    Kaçan, Erkan; Ulgen, Koray; Kaçan, Erdal

    2015-01-01

    Highlights: • The efficiency effect of 4 independent parameters over the solar heating system are examined. • 3 of 4 independent parameters are found as decisive parameter for system design. • Maximum exergetic efficiency exceeded 11% at optimized process. • Maximum environmental efficiency reached up to 95% at optimized process. • The optimum outside temperature and solar radiation are found as 22 °C and 773 W/m"2 for all responses. - Abstract: Researchers are rather closely involved in Solar Combisystems recently, but there is lack of study that presents the optimum design parameters. Therefore, in this study the influence of the four major variables, namely; outside, inside temperature, solar radiation on horizontal surface and instantaneous efficiency of solar collector on the energetic, exergetic and environmental efficiencies of Solar Combisystems are investigated and system optimization is done by a combination of response surface methodology. Measured parameters and energetic–exergetic and environmental performance curves are found and statistical model is created parallel with the actual data. It is found that statistical model is significant and all “lack-of-fit” values are non-significant. Thus, it is proved that statistical model strongly represents the design model. Outside temperature, solar radiation on horizontal surface and instantaneous efficiency of solar collector are the decisive parameters for all responses but instantaneous efficiency of solar collector is not for environmental efficiency. Maximum exergetic efficiency exceeded 11%, maximum environmental efficiency reached up to 95% at optimized process. The optimum value of the outside temperature and solar radiation are found as 22 °C and 773 W/m"2 for all responses, on the other hand optimum collector efficiency is found around 60% for energetic and exergetic efficiency values. Inside temperature is not a decisive parameter for all responses.

  17. Compact printed multiband antenna with independent setting suitable for fixed and reconfigurable wireless communication systems

    KAUST Repository

    Abutarboush, Hattan

    2012-08-01

    This paper presents the design of a low-profile compact printed antenna for fixed frequency and reconfigurable frequency bands. The antenna consists of a main patch, four sub-patches, and a ground plane to generate five frequency bands, at 0.92, 1.73, 1.98, 2.4, and 2.9 GHz, for different wireless systems. For the fixed-frequency design, the five individual frequency bands can be adjusted and set independently over the wide ranges of 18.78%, 22.75%, 4.51%, 11%, and 8.21%, respectively, using just one parameter of the antenna. By putting a varactor (diode) at each of the sub-patch inputs, four of the frequency bands can be controlled independently over wide ranges and the antenna has a reconfigurable design. The tunability ranges for the four bands of 0.92, 1.73, 1.98, and 2.9 GHz are 23.5%, 10.30%, 13.5%, and 3%, respectively. The fixed and reconfigurable designs are studied using computer simulation. For verification of simulation results, the two designs are fabricated and the prototypes are measured. The results show a good agreement between simulated and measured results. © 1963-2012 IEEE.

  18. Independent Orbiter Assessment (IOA): Assessment of the orbital maneuvering system FMEA/CIL, volume 1

    Science.gov (United States)

    Prust, Chet D.; Haufler, W. A.; Marino, A. J.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Orbital Maneuvering System (OMS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter OMS hardware. The IOA analysis defined the OMS as being comprised of the following subsystems: helium pressurization, propellant storage and distribution, Orbital Maneuvering Engine, and EPD and C. The IOA product for the OMS analysis consisted of 284 hardware and 667 EPD and C failure mode worksheets that resulted in 160 hardware and 216 EPD and C potential critical items (PCIs) being identified. A comparison was made of the IOA product to the NASA FMEA/CIL baseline which consisted of 101 hardware and 142 EPD and C CIL items.

  19. Independent Orbiter Assessment (IOA): Assessment of the remote manipulator system FMEA/CIL

    Science.gov (United States)

    Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Remote Manipulator System (RMS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter RMS hardware are documented. The IOA product for the RMS analysis consisted of 604 failure mode worksheets that resulted in 458 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 45 FMEAs and 321 CIL items. This comparison produced agreement on all but 154 FMEAs which caused differences in 137 CIL items.

  20. Compact printed multiband antenna with independent setting suitable for fixed and reconfigurable wireless communication systems

    KAUST Repository

    Abutarboush, Hattan; Nilavalan, Rajagopal; Cheung, Sing Wai; Nasr, Karim Medhat A

    2012-01-01

    This paper presents the design of a low-profile compact printed antenna for fixed frequency and reconfigurable frequency bands. The antenna consists of a main patch, four sub-patches, and a ground plane to generate five frequency bands, at 0.92, 1.73, 1.98, 2.4, and 2.9 GHz, for different wireless systems. For the fixed-frequency design, the five individual frequency bands can be adjusted and set independently over the wide ranges of 18.78%, 22.75%, 4.51%, 11%, and 8.21%, respectively, using just one parameter of the antenna. By putting a varactor (diode) at each of the sub-patch inputs, four of the frequency bands can be controlled independently over wide ranges and the antenna has a reconfigurable design. The tunability ranges for the four bands of 0.92, 1.73, 1.98, and 2.9 GHz are 23.5%, 10.30%, 13.5%, and 3%, respectively. The fixed and reconfigurable designs are studied using computer simulation. For verification of simulation results, the two designs are fabricated and the prototypes are measured. The results show a good agreement between simulated and measured results. © 1963-2012 IEEE.

  1. Possible configurations for an air independent propulsion (AIP) system for submarines based on fuel cells

    International Nuclear Information System (INIS)

    Bordallo, C.R.; Moreno, E.; Brey, J.J.; Garcia, C.; Sarmiento, B.; Castro, A.

    2004-01-01

    'Full text:' Conventional submarines employ an electric propulsion system, based on energy storage in batteries which are recharged using diesel motors connected to generator alternators. This limits their autonomy underwater given that it will be depend on the amount of energy that can be stored in the batteries; currently, a normal value is to have energy to navigate for three days at low speed. As of from the WWII, several shipyards began to carry out research on propulsion systems for submarines that would be capable of operating under anaerobic conditions, independent of the air (AIP Systems). Since then, several proposals have been considered, but there is one option that several navies are currently putting their trust in: fuel cells. The objective of this Project is to stress the different configurations that can be considered to this end, as regards the transportation of hydrogen and oxygen. From the hydrogen point of view, the possibilities of transporting it in metal hydrides or its on-board production through the reforming of different fuels (gas-oil, ethanol, methanol), are analyzed. This study also compares auxiliary systems (including CO2 removers), and proposes solutions, some of which are under development, indicating which are currently being considered to a greater extent. (author)

  2. Possible configurations for an air independent propulsion (AIP) system for submarines based on fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Bordallo, C.R.; Moreno, E.; Brey, J.J.; Garcia, C.; Sarmiento, B.; Castro, A. [Hynergreen Technologies, S.A., Seville (Spain)

    2004-07-01

    'Full text:' Conventional submarines employ an electric propulsion system, based on energy storage in batteries which are recharged using diesel motors connected to generator alternators. This limits their autonomy underwater given that it will be depend on the amount of energy that can be stored in the batteries; currently, a normal value is to have energy to navigate for three days at low speed. As of from the WWII, several shipyards began to carry out research on propulsion systems for submarines that would be capable of operating under anaerobic conditions, independent of the air (AIP Systems). Since then, several proposals have been considered, but there is one option that several navies are currently putting their trust in: fuel cells. The objective of this Project is to stress the different configurations that can be considered to this end, as regards the transportation of hydrogen and oxygen. From the hydrogen point of view, the possibilities of transporting it in metal hydrides or its on-board production through the reforming of different fuels (gas-oil, ethanol, methanol), are analyzed. This study also compares auxiliary systems (including CO2 removers), and proposes solutions, some of which are under development, indicating which are currently being considered to a greater extent. (author)

  3. Cross-validation of independent ultra-low-frequency magnetic recording systems for active fault studies

    Science.gov (United States)

    Wang, Can; Bin, Chen; Christman, Lilianna E.; Glen, Jonathan M. G.; Klemperer, Simon L.; McPhee, Darcy K.; Kappler, Karl N.; Bleier, Tom E.; Dunson, J. Clark

    2018-04-01

    When working with ultra-low-frequency (ULF) magnetic datasets, as with most geophysical time-series data, it is important to be able to distinguish between cultural signals, internal instrument noise, and natural external signals with their induced telluric fields. This distinction is commonly attempted using simultaneously recorded data from a spatially remote reference site. Here, instead, we compared data recorded by two systems with different instrumental characteristics at the same location over the same time period. We collocated two independent ULF magnetic systems, one from the QuakeFinder network and the other from the United States Geological Survey (USGS)-Stanford network, in order to cross-compare their data, characterize data reproducibility, and characterize signal origin. In addition, we used simultaneous measurements at a remote geomagnetic observatory to distinguish global atmospheric signals from local cultural signals. We demonstrated that the QuakeFinder and USGS-Stanford systems have excellent coherence, despite their different sensors and digitizers. Rare instances of isolated signals recorded by only one system or only one sensor indicate that caution is needed when attributing specific recorded signal features to specific origins.[Figure not available: see fulltext.

  4. Determining the Frequency for Load-Independent Output Current in Three-Coil Wireless Power Transfer System

    Directory of Open Access Journals (Sweden)

    Longzhao Sun

    2015-09-01

    Full Text Available Conditions for load-independent output voltage or current in two-coil wireless power transfer (WPT systems have been studied. However, analysis of load-independent output current in three-coil WPT system is still lacking in previous studies. This paper investigates the output current characteristics of a three-coil WPT system against load variations, and determines the operating frequency to achieve a constant output current. First, a three-coil WPT system is modeled by circuit theory, and the analytical expression of the root-mean-square of the output current is derived. By substituting the coupling coefficients, the quality factor, and the resonant frequency of each coil, we propose a method of calculating the frequency for load-independent output current in a three-coil WPT system, which indicates that there are two frequencies that can achieve load-independent output current. Experiments are conducted to validate these analytical results.

  5. Sensor System for Long-term Recording of Photovoltaic (PV) IV-curves

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    The purpose of this paper is to present a recording system for long-term investigation of PV panel dynamics under partial shading conditions. The system is intended to be a low-cost system deployable for stand-alone field use and long-term data recording at PV-plants. Passing clouds will affect...

  6. Central Nervous System Demyelination and Remyelination is Independent from Systemic Cholesterol Level in Theiler's Murine Encephalomyelitis.

    Science.gov (United States)

    Raddatz, Barbara B; Sun, Wenhui; Brogden, Graham; Sun, Yanyong; Kammeyer, Patricia; Kalkuhl, Arno; Colbatzky, Florian; Deschl, Ulrich; Naim, Hassan Y; Baumgärtner, Wolfgang; Ulrich, Reiner

    2016-01-01

    High dietary fat and/or cholesterol intake is a risk factor for multiple diseases and has been debated for multiple sclerosis. However, cholesterol biosynthesis is a key pathway during myelination and disturbances are described in demyelinating diseases. To address the possible interaction of dyslipidemia and demyelination, cholesterol biosynthesis gene expression, composition of the body's major lipid repositories and Paigen diet-induced, systemic hypercholesterolemia were examined in Theiler's murine encephalomyelitis (TME) using histology, immunohistochemistry, serum clinical chemistry, microarrays and high-performance thin layer chromatography. TME-virus (TMEV)-infected mice showed progressive loss of motor performance and demyelinating leukomyelitis. Gene expression associated with cholesterol biosynthesis was overall down-regulated in the spinal cord of TMEV-infected animals. Spinal cord levels of galactocerebroside and sphingomyelin were reduced on day 196 post TMEV infection. Paigen diet induced serum hypercholesterolemia and hepatic lipidosis. However, high dietary fat and cholesterol intake led to no significant differences in clinical course, inflammatory response, astrocytosis, and the amount of demyelination and remyelination in the spinal cord of TMEV-infected animals. The results suggest that down-regulation of cholesterol biosynthesis is a transcriptional marker for demyelination, quantitative loss of myelin-specific lipids, but not cholesterol occurs late in chronic demyelination, and serum hypercholesterolemia exhibited no significant effect on TMEV infection. © 2015 International Society of Neuropathology.

  7. A Discrete Event System Approach to Online Testing of Speed Independent Circuits

    Directory of Open Access Journals (Sweden)

    P. K. Biswal

    2015-01-01

    Full Text Available With the increase in soft failures in deep submicron ICs, online testing is becoming an integral part of design for testability. Some techniques for online testing of asynchronous circuits are proposed in the literature, which involves development of a checker that verifies the correctness of the protocol. This checker involves Mutex blocks making its area overhead quite high. In this paper, we have adapted the Theory of Fault Detection and Diagnosis available in the literature on Discrete Event Systems to online testing of speed independent asynchronous circuits. The scheme involves development of a state based model of the circuit, under normal and various stuck-at fault conditions, and finally designing state estimators termed as detectors. The detectors monitor the circuit online and determine whether it is functioning in normal/failure mode. The main advantages are nonintrusiveness and low area overheads compared to similar schemes reported in the literature.

  8. Nanoformulations of Rilpivirine for Topical Pericoital and Systemic Coitus-Independent Administration Efficiently Prevent HIV Transmission

    Science.gov (United States)

    Date, Abhijit A.; Long, Julie M.; Nochii, Tomonori; Belshan, Michael; Shibata, Annemarie; Vincent, Heather; Baker, Caroline E.; Thayer, William O.; Kraus, Guenter; Lachaud-Durand, Sophie; Williams, Peter; Destache, Christopher J.; Garcia, J. Victor

    2015-01-01

    Vaginal HIV transmission accounts for the majority of new infections worldwide. Currently, multiple efforts to prevent HIV transmission are based on pre-exposure prophylaxis with various antiretroviral drugs. Here, we describe two novel nanoformulations of the reverse transcriptase inhibitor rilpivirine for pericoital and coitus-independent HIV prevention. Topically applied rilpivirine, encapsulated in PLGA nanoparticles, was delivered in a thermosensitive gel, which becomes solid at body temperature. PLGA nanoparticles with encapsulated rilpivirine coated the reproductive tract and offered significant protection to BLT humanized mice from a vaginal high-dose HIV-1 challenge. A different nanosuspension of crystalline rilpivirine (RPV LA), administered intramuscularly, protected BLT mice from a single vaginal high-dose HIV-1 challenge one week after drug administration. Using transmitted/founder viruses, which were previously shown to establish de novo infection in humans, we demonstrated that RPV LA offers significant protection from two consecutive high-dose HIV-1 challenges one and four weeks after drug administration. In this experiment, we also showed that, in certain cases, even in the presence of drug, HIV infection could occur without overt or detectable systemic replication until levels of drug were reduced. We also showed that infection in the presence of drug can result in acquisition of multiple viruses after subsequent exposures. These observations have important implications for the implementation of long-acting antiretroviral formulations for HIV prevention. They provide first evidence that occult infections can occur, despite the presence of sustained levels of antiretroviral drugs. Together, our results demonstrate that topically- or systemically administered rilpivirine offers significant coitus-dependent or coitus-independent protection from HIV infection. PMID:26271040

  9. A PLC platform-independent structural analysis on FBD programs for digital reactor protection systems

    International Nuclear Information System (INIS)

    Jung, Sejin; Yoo, Junbeom; Lee, Young-Jun

    2017-01-01

    Highlights: • FBD has been widely used to implement safety-critical software for PLC-based systems. • The safety-critical software should be developed strictly with safety programming guidelines. • There are no argued rules that have specific links to higher guidelines NUREG/CR-6463 PLC platform-independently. • This paper proposes a set of rules on the structure of FBD programs with providing specific links to higher guidelines. • This paper also provides CASE tool ‘FBD Checker’ for analyzing the structure of FBD. - Abstract: FBD (function block diagram) has been widely used to implement safety-critical software for PLC (programmable logic controller)-based digital nuclear reactor protection systems. The software should be developed strictly in accordance with safety programming guidelines such as NUREG/CR-6463. Software engineering tools of PLC vendors enable us to present structural analyses using FBD programs, but specific rules pertaining to the guidelines are enclosed within the commercial tools, and specific links to the guidelines are not clearly communicated. This paper proposes a set of rules on the structure of FBD programs in accordance with guidelines, and we develop an automatic analysis tool for FBD programs written in the PLCopen TC6 format. With the proposed tool, any FBD program that is transformed into an open format can be analyzed the PLC platform-independently. We consider a case study on FBD programs obtained from a preliminary version of a Korean nuclear power plant, and we demonstrate the effectiveness and potential of the proposed rules and analysis tool.

  10. Culture-independent analysis of aerosol microbiology in a metropolitan subway system.

    Science.gov (United States)

    Robertson, Charles E; Baumgartner, Laura K; Harris, J Kirk; Peterson, Kristen L; Stevens, Mark J; Frank, Daniel N; Pace, Norman R

    2013-06-01

    The goal of this study was to determine the composition and diversity of microorganisms associated with bioaerosols in a heavily trafficked metropolitan subway environment. We collected bioaerosols by fluid impingement on several New York City subway platforms and associated sites in three sampling sessions over a 1.5-year period. The types and quantities of aerosolized microorganisms were determined by culture-independent phylogenetic analysis of small-subunit rRNA gene sequences by using both Sanger (universal) and pyrosequencing (bacterial) technologies. Overall, the subway bacterial composition was relatively simple; only 26 taxonomic families made up ~75% of the sequences determined. The microbiology was more or less similar throughout the system and with time and was most similar to outdoor air, consistent with highly efficient air mixing in the system. Identifiable bacterial sequences indicated that the subway aerosol assemblage was composed of a mixture of genera and species characteristic of soil, environmental water, and human skin commensal bacteria. Eukaryotic diversity was mainly fungal, dominated by organisms of types associated with wood rot. Human skin bacterial species (at 99% rRNA sequence identity) included the Staphylococcus spp. Staphylococcus epidermidis (the most abundant and prevalent commensal of the human integument), S. hominis, S. cohnii, S. caprae, and S. haemolyticus, all well-documented human commensal bacteria. We encountered no organisms of public health concern. This study is the most extensive culture-independent survey of subway microbiota so far and puts in place pre-event information required for any bioterrorism surveillance activities or monitoring of the microbiological impact of recent subway flooding events.

  11. Grating exchange system of independent mirror supported by floating rotary stage

    Science.gov (United States)

    Zhang, Jianhuan; Tao, Jin; Liu, Yan; Nan, Yan

    2015-10-01

    The performance of The Grating Exchange System can satisfy the Thirty Meter Telescope - TMT for astronomical observation WFOS index requirements and satisfy the requirement of accuracy in the grating exchange. It is used to install in the MOBIE and a key device of MOBIE. The Wide Field Optical Spectrograph (WFOS) is one of the three first-light observing capabilities selected by the TMT Science Advisory Committee. The Multi-Object Broadband Imaging Echellette (MOBIE) instrument design concept has been developed to address the WFOS requirements as described in the TMT Science-Based Requirements Document (SRD). The Grating Exchange System uses a new type of separate movement way of three grating devices and a mirror device. Three grating devices with a mirror are able to achieve independence movement. This kind of grating exchange system can effectively solve the problem that the volume of the grating change system is too large and that the installed space of MOBIE instruments is too limit. This system adopts the good stability, high precision of rotary stage - a kind of using air bearing (Air bearing is famous for its ultra-high precision, and can meet the optical accuracy requirement) and rotation positioning feedback gauge turntable to support grating device. And with a kind of device which can carry greater weight bracket fixed on the MOBIE instrument, with two sets of servo motor control rotary stage and the mirror device respectively. And we use the control program to realize the need of exercising of the grating device and the mirror device. Using the stress strain analysis software--SolidWorks for stress and strain analysis of this structure. And then checking the structure of the rationality and feasibility. And prove that this system can realize the positioning precision under different working conditions can meet the requirements of imaging optical grating diffraction efficiency and error by the calculation and optical performance analysis.

  12. Feeding induced by cannabinoids is mediated independently of the melanocortin system.

    Directory of Open Access Journals (Sweden)

    Puspha Sinnayah

    2008-05-01

    Full Text Available Cannabinoids, the active components of marijuana, stimulate appetite, and cannabinoid receptor-1 (CB1-R antagonists suppress appetite and promote weight loss. Little is known about how CB1-R antagonists affect the central neurocircuitry, specifically the melanocortin system that regulates energy balance.Here, we show that peripherally administered CB1-R antagonist (AM251 or agonist equally suppressed or stimulated feeding respectively in A(y , which lack a functional melanocortin system, and wildtype mice, demonstrating that cannabinoid effects on feeding do not require melanocortin circuitry. CB1-R antagonist or agonist administered into the ventral tegmental area (VTA equally suppressed or stimulated feeding respectively, in both genotypes. In addition, peripheral and central cannabinoid administration similarly induced c-Fos activation in brain sites suggesting mediation via motivational dopaminergic circuitry. Amperometry-detected increases in evoked dopamine (DA release by the CB1-R antagonist in nucleus accumbens slices indicates that AM251 modulates DA release from VTA terminals.Our results demonstrate that the effects of cannabinoids on energy balance are independent of hypothalamic melanocortin circuitry and is primarily driven by the reward system.

  13. A FAST AND ELITIST BI-OBJECTIVE EVOLUTIONARY ALGORITHM FOR SCHEDULING INDEPENDENT TASKS ON HETEROGENEOUS SYSTEMS

    Directory of Open Access Journals (Sweden)

    G.Subashini

    2010-07-01

    Full Text Available To meet the increasing computational demands, geographically distributed resources need to be logically coupled to make them work as a unified resource. In analyzing the performance of such distributed heterogeneous computing systems scheduling a set of tasks to the available set of resources for execution is highly important. Task scheduling being an NP-complete problem, use of metaheuristics is more appropriate in obtaining optimal solutions. Schedules thus obtained can be evaluated using several criteria that may conflict with one another which require multi objective problem formulation. This paper investigates the application of an elitist Nondominated Sorting Genetic Algorithm (NSGA-II, to efficiently schedule a set of independent tasks in a heterogeneous distributed computing system. The objectives considered in this paper include minimizing makespan and average flowtime simultaneously. The implementation of NSGA-II algorithm and Weighted-Sum Genetic Algorithm (WSGA has been tested on benchmark instances for distributed heterogeneous systems. As NSGA-II generates a set of Pareto optimal solutions, to verify the effectiveness of NSGA-II over WSGA a fuzzy based membership value assignment method is employed to choose the best compromise solution from the obtained Pareto solution set.

  14. A Study on the Inter-Channel Communication Independence for SMART I and C System

    International Nuclear Information System (INIS)

    Jeong, Kwang Il; Keum, Jong Yong; Park, Je Yun

    2009-01-01

    In nuclear power plants (NPP) the greatest concern is to ensure the safety goal, so it is designed with a protection conception using diversity and redundancy methods. Usually the I and C (Instrumentation and Control) system of NPP is composed of four channels to enhance the performance of the safety functions and performs the monitoring and control functions. In these redundant structures, the most important thing is that a malfunction in one channel cannot affect the safety functions of the redundant channels. The communication network of the digital I and C system is playing a role in intra-channel communication and inter-channel communication in four-channel I and C structure. Recent licensee experience indicates that companies planning to use the interchannel communication must perform a detailed analysis of all credible failure modes. In this paper, we propose some evaluation criteria to evaluate the inter-channel communication independence of SMART I and C system and preliminary design for mitigating methodologies of each credible failure

  15. The evolutionary New England experience and the role of the independent system operator (ISO)

    International Nuclear Information System (INIS)

    Sinclair, J.

    1998-01-01

    The evolution of the New England pool (NEPOOL) that treats the whole of the New England Region as one utility control area, is discussed. NEPOOL was established in 1971 in response to the 1965 blackout. The goal of the NEPOOL is to improve electric power reliability and efficiency. Discussions to restructure the New England market place began in 1994 and again later in 1996 with FERC order 888 which proposed the establishment of an independent system operator (ISO) and with the NEPOOL 888 filing in December of 1996, which defined the role of the ISO, the underlying principles being non-discriminatory governance, system operations, and market administration and transmission service. This speaker described the structure of the nation's first ISO, the principles of its operations regarding open access, single tariff, pricing for efficient resource use, open access same-time information systems, as well as its roles that go beyond the FERC definitions. Characteristic features of the energy market in New England are also described, along with some 50 current new power plant projects under consideration; not unexpectedly, all of them will be powered by natural gas

  16. Integrating an embedded system in a microwave moisture meter

    Science.gov (United States)

    The conversion of a PC- or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter measures the attenuation and phase shift of low power microwaves traversing the sample, from which the dielectric properties are calculated. T...

  17. Integrating an Embedded System within a Microwave Moisture Meter

    Science.gov (United States)

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter uses low-power microwaves to measure the attenuation and phase shift of the sample, from which the dielectric properties are cal...

  18. PVSOFT99 - Photovoltaic (PV) System Sizing And Simulation Software

    African Journals Online (AJOL)

    A computer program (PVSOFT99) has been developed for sizing and simulation of stand-alone photovoltaic (PV) systems. Two distinct PV sizing algorithms, one based on the worst case and the other on the reliability concept, have been incorporated in the program. The reliability concept is generalized in that variation of ...

  19. Development of micro controller-based monitoring system for a ...

    African Journals Online (AJOL)

    Development of micro controller-based monitoring system for a stand-alone ... which are then processed by a microcontroller with Arduino Board and the ... used in meteorological stations and laboratory for measurements of the same parameters. ... 0.0412%,-0.297% and 0.024% for solar radiation intensity, temperature, ...

  20. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    Klüter, Sebastian, E-mail: sebastian.klueter@med.uni-heidelberg.de; Schubert, Kai; Lissner, Steffen; Sterzing, Florian; Oetzel, Dieter; Debus, Jürgen [Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany, and Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany, and German Consortium for Translational Cancer Research (DKTK), Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Schlegel, Wolfgang [German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Oelfke, Uwe [German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom); Nill, Simeon [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom)

    2014-08-15

    Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local

  1. Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

    International Nuclear Information System (INIS)

    Klüter, Sebastian; Schubert, Kai; Lissner, Steffen; Sterzing, Florian; Oetzel, Dieter; Debus, Jürgen; Schlegel, Wolfgang; Oelfke, Uwe; Nill, Simeon

    2014-01-01

    Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local

  2. Time-independent and time-dependent contributions to the unavailability of standby safety system components

    International Nuclear Information System (INIS)

    Lofgren, E.V.; Uryasev, S.; Samanta, P.

    1997-01-01

    The unavailability of standby safety system components due to failures in nuclear power plants is considered to involve a time-independent and a time-dependent part. The former relates to the component's unavailability from demand stresses due to usage, and the latter represents the component's unavailability due to standby-time stresses related to the environment. In this paper, data from the nuclear plant reliability data system (NPRDS) were used to partition the component's unavailability into the contributions from standby-time stress (i.e., due to environmental factors) and demand stress (i.e., due to usage). Analyses are presented of motor-operated valves (MOVs), motor-driven pumps (MDPs), and turbine-driven pumps (TDPs). MOVs fail predominantly (approx. 78 %) from environmental factors (standby-time stress failures). MDPs fail slightly more frequently from demand stresses (approx. 63 %) than standby-time stresses, while TDPs fail predominantly from standby-time stresses (approx. 78 %). Such partitions of component unavailability have many uses in risk-informed and performance-based regulation relating to modifications to Technical Specification, in-service testing, precise determination of dominant accident sequences, and implementation of maintenance rules

  3. Riccati and Ermakov Equations in Time-Dependent and Time-Independent Quantum Systems

    Directory of Open Access Journals (Sweden)

    Dieter Schuch

    2008-05-01

    Full Text Available The time-evolution of the maximum and the width of exact analytic wave packet (WP solutions of the time-dependent Schrödinger equation (SE represents the particle and wave aspects, respectively, of the quantum system. The dynamics of the maximum, located at the mean value of position, is governed by the Newtonian equation of the corresponding classical problem. The width, which is directly proportional to the position uncertainty, obeys a complex nonlinear Riccati equation which can be transformed into a real nonlinear Ermakov equation. The coupled pair of these equations yields a dynamical invariant which plays a key role in our investigation. It can be expressed in terms of a complex variable that linearizes the Riccati equation. This variable also provides the time-dependent parameters that characterize the Green's function, or Feynman kernel, of the corresponding problem. From there, also the relation between the classical and quantum dynamics of the systems can be obtained. Furthermore, the close connection between the Ermakov invariant and the Wigner function will be shown. Factorization of the dynamical invariant allows for comparison with creation/annihilation operators and supersymmetry where the partner potentials fulfil (real Riccati equations. This provides the link to a nonlinear formulation of time-independent quantum mechanics in terms of an Ermakov equation for the amplitude of the stationary state wave functions combined with a conservation law. Comparison with SUSY and the time-dependent problems concludes our analysis.

  4. Evaluation of soft segment modeling on a context independent phoneme classification system

    International Nuclear Information System (INIS)

    Razzazi, F.; Sayadiyan, A.

    2007-01-01

    The geometric distribution of states duration is one of the main performance limiting assumptions of hidden Markov modeling of speech signals. Stochastic segment models, generally, and segmental HMM, specifically overcome this deficiency partly at the cost of more complexity in both training and recognition phases. In addition to this assumption, the gradual temporal changes of speech statistics has not been modeled in HMM. In this paper, a new duration modeling approach is presented. The main idea of the model is to consider the effect of adjacent segments on the probability density function estimation and evaluation of each acoustic segment. This idea not only makes the model robust against segmentation errors, but also it models gradual change from one segment to the next one with a minimum set of parameters. The proposed idea is analytically formulated and tested on a TIMIT based context independent phenomena classification system. During the test procedure, the phoneme classification of different phoneme classes was performed by applying various proposed recognition algorithms. The system was optimized and the results have been compared with a continuous density hidden Markov model (CDHMM) with similar computational complexity. The results show 8-10% improvement in phoneme recognition rate in comparison with standard continuous density hidden Markov model. This indicates improved compatibility of the proposed model with the speech nature. (author)

  5. Photovoltaic power generating system; Sanso zetsuengata taiyoko inverter

    Energy Technology Data Exchange (ETDEWEB)

    Nojima, T; Nakashima, T; Muta, Y; Takase, K; Hirayama, K [Nishimu Electronics Industries Co. Ltd., Saga (Japan)

    1996-10-27

    Nishimu Electronics Industries Co., Ltd. has developed a new series of inverters of three phase photovoltaic power generating system with the output ranging from 10 kVA to 50 kVA. For these inverters, the inverter and the system interconnection protector were integrated to make them smaller, lighter and cheaper. Stand-alone operation function was also added. The DC input voltage ranges were between 240 and 400 V for the crystalline solar cell, and between 170 and 400 V for the amorphous one. From the viewpoint of control of inverters, the inverters are generally controlled by the voltage-type current control method during the interconnection operation, while they must be controlled by the voltage-type voltage control method during the stand-alone operation which is the same as the UPS usually operated alone. For the present inverters, two control circuits for the interconnection operation and for the stand-alone operation were prepared. The control circuits for interconnection and stand-alone operations were switched using a cam-operation switch for change-over of operation. The results of the system interconnection verification tests satisfied the criteria of Japan`s Electronic Products Test Center. 3 refs., 4 figs., 2 tabs.

  6. Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation

    International Nuclear Information System (INIS)

    Jensen, Michael D.; Hrinivich, W. Thomas; Jung, Jongho A.; Holdsworth, David W.; Drangova, Maria; Chen, Jeff; Wong, Eugene

    2013-01-01

    Purpose: To design, construct, and commission a set of computer-controlled motorized jaws for a micro-CT/RT system to perform conformal image-guided small animal radiotherapy.Methods: The authors designed and evaluated a system of custom-built motorized orthogonal jaws, which allows the delivery of off-axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y-direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm 2 were measured using EBT2 film in the center of a 70 × 70 × 22 mm 3 solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm 3 . A calibrated Farmer ion chamber in a 70 × 70 × 20 mm 3 solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm 2 . Elliptical target plans were delivered to films to assess overall system performance. Respiratory-gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro-CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image-guided partial lung irradiation in a rat is demonstrated.Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory-gated treatments applied to a phantom moving with a peak-to-peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to 0.8 mm.Conclusions: A

  7. Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Michael D. [Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Hrinivich, W. Thomas; Jung, Jongho A. [Department of Physics and Astronomy, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Holdsworth, David W. [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (Canada); Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Surgery, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Drangova, Maria [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8, Canada and Department of Medical Biophysics, The University of Western Ontario 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Chen, Jeff [Department of Physics and Engineering, London Regional Cancer Program, London Health Sciences Centre, 800 Commissioners Road East, London, Ontario N6A 5W9 (Canada); Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Wong, Eugene [Department of Physics and Astronomy, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Physics and Engineering, London Regional Cancer Program, London Health Sciences Centre, 800 Commissioners Road East, London, Ontario N6A 5W9 (Canada)

    2013-08-15

    Purpose: To design, construct, and commission a set of computer-controlled motorized jaws for a micro-CT/RT system to perform conformal image-guided small animal radiotherapy.Methods: The authors designed and evaluated a system of custom-built motorized orthogonal jaws, which allows the delivery of off-axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y-direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm{sup 2} were measured using EBT2 film in the center of a 70 × 70 × 22 mm{sup 3} solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm{sup 3}. A calibrated Farmer ion chamber in a 70 × 70 × 20 mm{sup 3} solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm{sup 2}. Elliptical target plans were delivered to films to assess overall system performance. Respiratory-gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro-CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image-guided partial lung irradiation in a rat is demonstrated.Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory-gated treatments applied to a phantom moving with a peak-to-peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to

  8. Progress in ambient assisted systems for independent living by the elderly.

    Science.gov (United States)

    Al-Shaqi, Riyad; Mourshed, Monjur; Rezgui, Yacine

    2016-01-01

    One of the challenges of the ageing population in many countries is the efficient delivery of health and care services, which is further complicated by the increase in neurological conditions among the elderly due to rising life expectancy. Personal care of the elderly is of concern to their relatives, in case they are alone in their homes and unforeseen circumstances occur, affecting their wellbeing. The alternative; i.e. care in nursing homes or hospitals is costly and increases further if specialized care is mobilized to patients' place of residence. Enabling technologies for independent living by the elderly such as the ambient assisted living systems (AALS) are seen as essential to enhancing care in a cost-effective manner. In light of significant advances in telecommunication, computing and sensor miniaturization, as well as the ubiquity of mobile and connected devices embodying the concept of the Internet of Things (IoT), end-to-end solutions for ambient assisted living have become a reality. The premise of such applications is the continuous and most often real-time monitoring of the environment and occupant behavior using an event-driven intelligent system, thereby providing a facility for monitoring and assessment, and triggering assistance as and when needed. As a growing area of research, it is essential to investigate the approaches for developing AALS in literature to identify current practices and directions for future research. This paper is, therefore, aimed at a comprehensive and critical review of the frameworks and sensor systems used in various ambient assisted living systems, as well as their objectives and relationships with care and clinical systems. Findings from our work suggest that most frameworks focused on activity monitoring for assessing immediate risks, while the opportunities for integrating environmental factors for analytics and decision-making, in particular for the long-term care were often overlooked. The potential for

  9. Characterization of Na+-linked and Na+-independent Cl-/HCO3- exchange systems in Chinese hamster lung fibroblasts

    International Nuclear Information System (INIS)

    Cassel, D.; Scharf, O.; Rotman, M.; Cragoe, E.J. Jr.; Katz, M.

    1988-01-01

    The PS120 variant of Chinese hamster lung fibroblasts which lacks Na + /H + exchange activity was used to investigate bicarbonate transport systems and their role in intracellular pH (pH/sub i/) regulation. When pH/sub i/ was decreased by acid load, bicarbonate caused pH/sub i/ increase and stimulated 36 Cl - efflux from the cells, both in a Na + -dependent manner. These results together with previous findings that bicarbonate stimulates 22 Na + uptake in PS120 cells demonstrate the presence of a Na + -linked Cl - /HCO 3 - exchange system. In cells with normal initial pH/sub i/, bicarbonate caused Na + -independent pH/sub i/ increase in Cl - -free solutions and stimulated Na + -independent 36 Cl - efflux, indicating that a Na + -independent Cl - /HCO 3 - exchanger is also present in the cell. Na + -linked and Na + -independent Cl - /HCO 3- exchange is apparently mediated by two distinct systems, since a [(tetrahydrofluorene-7-yl)oxy]acetic acid derivative selectively inhibits the Na + -independent exchanger. An additional distinctive features is a 10-fold lower affinity for chloride of the Na + -linked exchanger. The Na + -linked and Na + -independent Cl - /HCO 3 - exchange systems are likely to protect the cell from acid and alkaline load, respectively

  10. Independent Safety Assessment of the TOPAZ-II space nuclear reactor power system (Revised)

    International Nuclear Information System (INIS)

    1993-09-01

    The Independent Safety Assessment described in this study report was performed to assess the safety of the design and launch plans anticipated by the U.S. Department of Defense (DOD) in 1993 for a Russian-built, U.S.-modified, TOPAZ-II space nuclear reactor power system. Its conclusions, and the bases for them, were intended to provide guidance for the U.S. Department of Energy (DOE) management in the event that the DOD requested authorization under section 91b. of the Atomic Energy Act of 1954, as amended, for possession and use (including ground testing and launch) of a nuclear-fueled, modified TOPAZ-II. The scientists and engineers who were engaged to perform this assessment are nationally-known nuclear safety experts in various disciplines. They met with participants in the TOPAZ-II program during the spring and summer of 1993 and produced a report based on their analysis of the proposed TOPAZ-II mission. Their conclusions were confined to the potential impact on public safety and did not include budgetary, reliability, or risk-benefit analyses

  11. PTEN phosphatase-independent maintenance of glandular morphology in a predictive colorectal cancer model system.

    Science.gov (United States)

    Jagan, Ishaan C; Deevi, Ravi K; Fatehullah, Aliya; Topley, Rebecca; Eves, Joshua; Stevenson, Michael; Loughrey, Maurice; Arthur, Kenneth; Campbell, Frederick Charles

    2013-11-01

    Organotypic models may provide mechanistic insight into colorectal cancer (CRC) morphology. Three-dimensional (3D) colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN) coupling of cell division cycle 42 (cdc42) to atypical protein kinase C (aPKC). This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM) orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3) were ineffective. The isolated PTEN C2 domain (C2) accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na(+)/H(+) exchanger regulatory factor-1 (NHERF-1) in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  12. PTEN Phosphatase-Independent Maintenance of Glandular Morphology in a Predictive Colorectal Cancer Model System

    Directory of Open Access Journals (Sweden)

    Ishaan C. Jagan

    2013-11-01

    Full Text Available Organotypic models may provide mechanistic insight into colorectal cancer (CRC morphology. Three-dimensional (3D colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN coupling of cell division cycle 42 (cdc42 to atypical protein kinase C (aPKC. This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3 were ineffective. The isolated PTEN C2 domain (C2 accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na+/H+ exchanger regulatory factor-1 (NHERF-1 in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  13. Design method for photovoltaics-battery storage systems under tropical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Salem, A I.E.; Bassyouni, A H; Al-Motawakel, M K

    1989-01-01

    A very limited number of the available design methods can be used with confidence in sizing and costing the stand-alone photovoltaic-battery storage systems operating under the weather conditions of the tropical countries located between 0 and 30/sup 0/N. For this reason we investigated the performance and economics of various photovoltaic-battery storage system configurations. The aim was to prepare a number of sizing and costing design diagrams which detail the effect of climatic, social, and economics parameters on the choice of the stand-alone photovoltaic-battery storage systems. Our strategy was to guide designers, particularly those trying to utilize the stand-alone photovoltaic-battery storage systems in Sana'a (15/sup 0/N) and Cairo (30/sup 0/N), to the logic for selecting a system that physically and economically matches the site potential and the user's electrical needs. Considered here are the relatively small stand-alone photovoltaic-battery storage systems that can be purchased by individuals or commercial and governmental firms to supply all or part of the electrical needs consumed in residence, farms, remote rural communities, or small factories.

  14. A free geometry model-independent neural eye-gaze tracking system

    Directory of Open Access Journals (Sweden)

    Gneo Massimo

    2012-11-01

    Full Text Available Abstract Background Eye Gaze Tracking Systems (EGTSs estimate the Point Of Gaze (POG of a user. In diagnostic applications EGTSs are used to study oculomotor characteristics and abnormalities, whereas in interactive applications EGTSs are proposed as input devices for human computer interfaces (HCI, e.g. to move a cursor on the screen when mouse control is not possible, such as in the case of assistive devices for people suffering from locked-in syndrome. If the user’s head remains still and the cornea rotates around its fixed centre, the pupil follows the eye in the images captured from one or more cameras, whereas the outer corneal reflection generated by an IR light source, i.e. glint, can be assumed as a fixed reference point. According to the so-called pupil centre corneal reflection method (PCCR, the POG can be thus estimated from the pupil-glint vector. Methods A new model-independent EGTS based on the PCCR is proposed. The mapping function based on artificial neural networks allows to avoid any specific model assumption and approximation either for the user’s eye physiology or for the system initial setup admitting a free geometry positioning for the user and the system components. The robustness of the proposed EGTS is proven by assessing its accuracy when tested on real data coming from: i different healthy users; ii different geometric settings of the camera and the light sources; iii different protocols based on the observation of points on a calibration grid and halfway points of a test grid. Results The achieved accuracy is approximately 0.49°, 0.41°, and 0.62° for respectively the horizontal, vertical and radial error of the POG. Conclusions The results prove the validity of the proposed approach as the proposed system performs better than EGTSs designed for HCI which, even if equipped with superior hardware, show accuracy values in the range 0.6°-1°.

  15. Development of a prototype interactive learning system using multi-media technology for mission independent training program

    Science.gov (United States)

    Matson, Jack E.

    1992-01-01

    The Spacelab Mission Independent Training Program provides an overview of payload operations. Most of the training material is currently presented in workbook form with some lecture sessions to supplement selected topics. The goal of this project was to develop a prototype interactive learning system for one of the Mission Independent Training topics to demonstrate how the learning process can be improved by incorporating multi-media technology into an interactive system. This report documents the development process and some of the problems encountered during the analysis, design, and production phases of this system.

  16. Topological and Graph-Coloring Conditions on the Parameter-Independent Stability of Second-Order Networked Systems

    NARCIS (Netherlands)

    Koerts, Filip; Bürger, Mathias; van der Schaft, Abraham; De Persis, Claudio

    2017-01-01

    In this paper, we study parameter-independent stability in qualitatively heterogeneous passive networked systems containing damped and undamped nodes. Given the graph topology and a set of damped nodes, we ask if output consensus is achieved for all system parameter values. For given parameter

  17. Determinants of Point-of-Sale System Adoption: A Survey among Small Independent Retailers in The Netherlands

    NARCIS (Netherlands)

    Plomp, M.G.A.; Huiden, R.P.; Batenburg, R.S.

    2011-01-01

    Several threats affect the survival of small, independent retail companies. Adoption and use of Point-of-Sale (POS) systems may offer important benefits to counter these threats. POS systems are not widely used by these retailers, however. This research investigates the determinants of the adoption

  18. Parallel Array Bistable Stochastic Resonance System with Independent Input and Its Signal-to-Noise Ratio Improvement

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-01-01

    with independent components and averaged output; second, we give a deduction of the output signal-to-noise ratio (SNR for this system to show the performance. Our examples show the enhancement of the system and how different parameters influence the performance of the proposed parallel array.

  19. Prototype system to recommend appropriate amount of independent musicians who matched user's preference

    OpenAIRE

    Uetake, Tomofumi; Kiyohara, Seiya

    2006-01-01

    Recently we can easily get music information at home. Furthermore, by using ''independent music community site''on lnternet, we can easily get songs of independent musicians. However, it is very difficult for us to look for the musician who matched one's preference. Because there is a great deal of number of the musicians, and a genre of a song is various. In this paper, We analyze the independent community music site in Japan and clarify the characteristics of the information about registere...

  20. Risk management and market efficiency on the Midwest Independent System Operator electricity exchange

    Science.gov (United States)

    Jones, Kevin

    Midwest Independent Transmission System Operator, Inc. (MISO) is a non-profit regional transmission organization (RTO) that oversees electricity production and transmission across thirteen states and one Canadian province. MISO also operates an electronic exchange for buying and selling electricity for each of its five regional hubs. MISO oversees two types of markets. The forward market, which is referred to as the day-ahead (DA) market, allows market participants to place demand bids and supply offers on electricity to be delivered at a specified hour the following day. The equilibrium price, known as the locational marginal price (LMP), is determined by MISO after receiving sale offers and purchase bids from market participants. MISO also coordinates a spot market, which is known as the real-time (RT) market. Traders in the real-time market must submit bids and offers by thirty minutes prior to the hour for which the trade will be executed. After receiving purchase and sale offers for a given hour in the real time market, MISO then determines the LMP for that particular hour. The existence of the DA and RT markets allows producers and retailers to hedge against the large fluctuations that are common in electricity prices. Hedge ratios on the MISO exchange are estimated using various techniques. No hedge ratio technique examined consistently outperforms the unhedged portfolio in terms of variance reduction. Consequently, none of the hedge ratio methods in this study meet the general interpretation of FASB guidelines for a highly effective hedge. One of the major goals of deregulation is to bring about competition and increased efficiency in electricity markets. Previous research suggests that electricity exchanges may not be weak-form market efficient. A simple moving average trading rule is found to produce statistically and economically significant profits on the MISO exchange. This could call the long-term survivability of the MISO exchange into question.