WorldWideScience

Sample records for stand-alone housing units

  1. Hydrogen-based energy storage unit for stand alone PV systems

    International Nuclear Information System (INIS)

    Labbe, J.

    2006-12-01

    Stand alone systems supplied only by a photovoltaic generator need an energy storage unit to be fully self sufficient. Lead acid batteries are commonly used to store energy because of their low cost, despite several operational constraints. A hydrogen-based energy storage unit (HESU) could be another candidate, including an electrolyser, a fuel cell and a hydrogen tank. However many efforts still need to be carried out for this technology to reach an industrial stage. In particular, market outlets must be clearly identified. The study of small stationary applications (few kW) is performed by numerical simulations. A simulator is developed in the Matlab/Simulink environment. It is mainly composed of a photovoltaic field and a storage unit (lead acid batteries, HESU, or hybrid storage HESU/batteries). The system component sizing is achieved in order to ensure the complete system autonomy over a whole year of operation. The simulator is tested with 160 load profiles (1 kW as a yearly mean value) and three locations (Algeria, France and Norway). Two coefficients are set in order to quantify the correlation between the power consumption of the end user and the renewable resource availability at both daily and yearly scales. Among the tested cases, a limit value of the yearly correlation coefficient came out, enabling to recommend the use of the most adapted storage to a considered case. There are cases for which using HESU instead of lead acid batteries can increase the system efficiency, decrease the size of the photovoltaic field and improve the exploitation of the renewable resource. In addition, hybridization of HESU with batteries always leads to system enhancements regarding its sizing and performance, with an efficiency increase by 10 to 40 % depending on the considered location. The good agreement between the simulation data and field data gathered on real systems enabled the validation of the models used in this study. (author)

  2. Radon Monitoring in Army Stand-Alone Housing Units

    Science.gov (United States)

    1990-04-01

    damage lung tissue and lead I to increased risk of developing lang cancer . Your risk of developing lung cancer from exposure to radon depends upon the...of developing lung cancer than exposure to a significantly elevated level for a short time. In general, your risk increases as the level of radon and...000mm 0Mmm *000 OOO 0 0w 0 0 000 -0-0 *4 0 880 mama 0 0000000000 000 000Eca ( el cN) 00 9 ’ qqO .00 1(10 0 -U M w co SEE wSS SEES NSEwESO m v MM O v mm

  3. Study on unitized inverter with photovoltaic grid-connected and stand-alone functions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haining; Su, Jianhui; Ding, Ming [Hefei University of Technology, Hefei (China)

    2008-07-01

    The main circuit and algorithm of unitized single phase inverter are presented, in which photovoltaic (PV) grid-connected algorithm, independency sine inverter algorithm and storage battery charge administer are all integrated basing on DSP (Digital Signal Processor). The control system identifies utility failure initiatively and then switches to independency power supply automatically. The methods of charging battery are multiform. Basing on material term to use utility or solar array to charge can optimize charge efficiency, assure the capacitance of battery and prolong life-span of battery. In addition, some results are offered basing on the prototype of a 2.5kW single phase inverter. (orig.)

  4. Stand-alone photovoltaic (PV) integrated with earth to air heat exchanger (EAHE) for space heating/cooling of adobe house in New Delhi (India)

    International Nuclear Information System (INIS)

    Chel, Arvind; Tiwari, G.N.

    2010-01-01

    This paper deals with an experimental outdoor annual performance evaluation of 2.32 kW P photovoltaic (PV) power system located at solar energy park in New Delhi composite climatic conditions. This PV system operates the daily electrical load nearly 10 kW h/day which comprises of various applications such as electric air blower of an earth to air heat exchanger (EAHE) used for heating/cooling of adobe house, ceiling fan, fluorescent tube-light, computer, submersible water pump, etc. The outdoor efficiencies, power generated and lost in PV system components were determined using hourly experimental measured data for 1 year on typical clear day in each month. These realistic data are useful for design engineers for outdoor assessment of PV system components. The energy conservation, mitigation of CO 2 emission and carbon credit potential of the existing PV integrated EAHE system is presented in this paper. Also, the energy payback time (EPBT) and unit cost of electricity were determined for both stand-alone PV (SAPV) and building roof integrated PV (BIPV) systems.

  5. Stand-alone XLIF

    DEFF Research Database (Denmark)

    Hansen, E. J.; Simony, A.; Hummel, Stefan

    2015-01-01

    and clinical/radiological results in 22 patients treated with XLIF procedure for DS or degenerative disc disease (DDD). Material and methods: 22 consecutive patients with DS underwent surgery with the XLIF stand-alone procedure, with follow-up of 24 months. Clinical outcome scores were collected. Complications......Introduction: Adult thoracolumbar degeneration is an increasing challenge in the aging population. With age the progressive degeneration of the discs leads to an asymmetric collapse and a thoracolumbar coronal plane deformity, a degenerative scoliosis (DS). Aim: To evaluate the complication rate......-year follow-up, with a 31.8% revision rate. Due to the high revision rate we recommend supplementary posterior instrumentation, to achieve a higher fusion rate. When considering XLIF-stand-alone procedure for DS or DDD without supplemental posterior instrumentation, only single-level disease should...

  6. Sizing, techno-economic and generation management analysis of a stand alone photovoltaic power unit including storage devices

    International Nuclear Information System (INIS)

    Jallouli, Rihab; Krichen, Lotfi

    2012-01-01

    Due to the mismatch between the load demand and the intermittent solar energy, a stand-alone photovoltaic-hydrogen system and an optimal control scheme are designed to maintain the high system efficiency. Based on meteorological and the load demand data, a system sizing technique is proposed to establish the minimum capacity of the system components, which are a photovoltaic (PV) panel, a proton exchange membrane fuel cell (PEMFC), a battery bank and an alkaline electrolyzer (Elz). An accurate energy management scheme that is utilized during power transfer is proposed to meet the economic requirements. Case studies are used to verify the efficiency of the energy management strategy and system sizing technique. Simulation results illustrate a simple solution to the design and processing of stand-alone PV-hydrogen (PV-H 2 ) systems. -- Highlights: ► We study a stand alone PV-hydrogen system comprising renewable devices. ► A PV generator, a battery bank, a fuel cell and an electrolyzer are modeled. ► Power management taking into account the economic arrangement and the operating conditions to ensure energy availability is proposed.

  7. Solar Charged Stand Alone Inverter

    OpenAIRE

    M.Vasugi; Prof R.Jayaraman

    2014-01-01

    This paper deals with solar powered stand alone inverter which converts the variable dc output of a photovoltaic solar panel into ac that can be fed to loads. Stand alone inverters are used in systems where the inverter get its energy from batteries charged by photo voltaic arrays. A charge controller limits the rate at which electric current is added to or drawn from electric batteries. This charge discharge controller is needed to prevent the battery from being overcharged o...

  8. Techno-economic assessment of FT unit for synthetic diesel production in existing stand-alone biomass gasification plant using process simulation tool

    DEFF Research Database (Denmark)

    Hunpinyo, Piyapong; Narataruksa, Phavanee; Tungkamani, Sabaithip

    2014-01-01

    For alternative thermo-chemical conversion process route via gasification, biomass can be gasified to produce syngas (mainly CO and H2). On more applications of utilization, syngas can be used to synthesize fuels through the catalytic process option for producing synthetic liquid fuels...... such as Fischer-Tropsch (FT) diesel. The embedding of the FT plant into the stand-alone based on power mode plants for production of a synthetic fuel is a promising practice, which requires an extensive adaptation of conventional techniques to the special chemical needs found in a gasified biomass. Because...... there are currently no plans to engage the FT process in Thailand, the authors have targeted that this work focus on improving the FT configurations in existing biomass gasification facilities (10 MWth). A process simulation model for calculating extended unit operations in a demonstrative context is designed...

  9. 39 CFR 122.2 - Stand-alone special services.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Stand-alone special services. 122.2 Section 122.2 Postal Service UNITED STATES POSTAL SERVICE POST OFFICE SERVICES [DOMESTIC MAIL] SERVICE STANDARDS FOR MARKET-DOMINANT SPECIAL SERVICES PRODUCTS § 122.2 Stand-alone special services. (a) The service standard...

  10. Hydrogen-based energy storage unit for stand alone PV systems; L'hydrogene electrolytique comme moyen de stockage d'electricite pour systemes photovoltaiques isoles

    Energy Technology Data Exchange (ETDEWEB)

    Labbe, J

    2006-12-15

    Stand alone systems supplied only by a photovoltaic generator need an energy storage unit to be fully self sufficient. Lead acid batteries are commonly used to store energy because of their low cost, despite several operational constraints. A hydrogen-based energy storage unit (HESU) could be another candidate, including an electrolyser, a fuel cell and a hydrogen tank. However many efforts still need to be carried out for this technology to reach an industrial stage. In particular, market outlets must be clearly identified. The study of small stationary applications (few kW) is performed by numerical simulations. A simulator is developed in the Matlab/Simulink environment. It is mainly composed of a photovoltaic field and a storage unit (lead acid batteries, HESU, or hybrid storage HESU/batteries). The system component sizing is achieved in order to ensure the complete system autonomy over a whole year of operation. The simulator is tested with 160 load profiles (1 kW as a yearly mean value) and three locations (Algeria, France and Norway). Two coefficients are set in order to quantify the correlation between the power consumption of the end user and the renewable resource availability at both daily and yearly scales. Among the tested cases, a limit value of the yearly correlation coefficient came out, enabling to recommend the use of the most adapted storage to a considered case. There are cases for which using HESU instead of lead acid batteries can increase the system efficiency, decrease the size of the photovoltaic field and improve the exploitation of the renewable resource. In addition, hybridization of HESU with batteries always leads to system enhancements regarding its sizing and performance, with an efficiency increase by 10 to 40 % depending on the considered location. The good agreement between the simulation data and field data gathered on real systems enabled the validation of the models used in this study. (author)

  11. Stand-alone photovoltaic applications. Lessons learned

    International Nuclear Information System (INIS)

    Loois, G.; Van Hemert, B.

    1999-02-01

    The IEA Photovoltaic Power Systems Programme (PVPS) is one of the collaborative R and D agreements established within the IEA. The objective of Task III is to promote and facilitate the exchange of information and experiences in the field of PV Systems in Stand-alone and Island Applications (SAPV). The book focuses on the practical experiences gained, and does not aim to provide a complete manual on SAPV. When Task III started its activities in 1993, a collection of 50 'State of the art' projects was published in the book 'Examples of Stand-Alone Photovoltaic Systems'. This publication marked the base line for the work of the task. Now, in 1998, the showcases from each country demonstrate the lessons learned in five years of cooperation. The book consists of two parts. The first part contains eight chapters dealing with a specific aspect of stand-alone PV. The second part introduces 14 national showcase projects in a systematic presentation. Each chapter and showcase can be read independently from the rest of the book. Chapter 2, contributed by The Netherlands, analyses the market for stand-alone PV systems. It gives an overview of the 'traditional' application of stand-alone PV, which is the electrification of remote buildings and which has been addressed in depth in other publications. The focus is on the market niches of service applications that are also interesting for more densely populated areas, e.g. in industrialised countries. The United Kingdom illustrates the economic aspects in Chapter 3. Cost comparisons are made, but more important is the illustration of the non-financial considerations that make PV the preferred choice as a power source for many applications. Switzerland explores in Chapter 4 (financing aspects) different financing mechanisms, and financial policies used to overcome the initial cost barrier. Most of these approaches have been applied in developing countries rather than in the western world. Using various examples from all over the

  12. The Stand-alone Heliostat

    International Nuclear Information System (INIS)

    Garcia Navajas, G. I.; Egea Gea, A.

    2000-01-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-nr, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modem working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modem. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced.by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs

  13. Grid parity analysis of stand-alone hybrid microgrids: A comparative study of Germany, Pakistan, South Africa and the United States

    Science.gov (United States)

    Siddiqui, Jawad M.

    Grid parity for alternative energy resources occurs when the cost of electricity generated from the source is lower than or equal to the purchasing price of power from the electricity grid. This thesis aims to quantitatively analyze the evolution of hybrid stand-alone microgrids in the US, Germany, Pakistan and South Africa to determine grid parity for a solar PV/Diesel/Battery hybrid system. The Energy System Model (ESM) and NREL's Hybrid Optimization of Multiple Energy Resources (HOMER) software are used to simulate the microgrid operation and determine a Levelized Cost of Electricity (LCOE) figure for each location. This cost per kWh is then compared with two distinct estimates of future retail electricity prices at each location to determine grid parity points. Analysis results reveal that future estimates of LCOE for such hybrid stand-alone microgrids range within the 35-55 cents/kWh over the 25 year study period. Grid parity occurs earlier in locations with higher power prices or unreliable grids. For Pakistan grid parity is already here, while Germany hits parity between the years 2023-2029. Results for South Africa suggest a parity time range of the years 2040-2045. In the US, places with low grid prices do not hit parity during the study period. Sensitivity analysis results reveal the significant impact of financing and the cost of capital on these grid parity points, particularly in developing markets of Pakistan and South Africa. Overall, the study helps conclude that variations in energy markets may determine the fate of emerging energy technologies like microgrids. However, policy interventions have a significant impact on the final outcome, such as the grid parity in this case. Measures such as eliminating uncertainty in policies and improving financing can help these grids overcome barriers in developing economies, where they may find a greater use much earlier in time.

  14. Basic Stand Alone Medicare Inpatient Claims PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Inpatient Public Use Files (PUF) named CMS 2008 BSA Inpatient Claims PUF with information from 2008 Medicare...

  15. Basic Stand Alone Carrier Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Carrier Line Items Public Use Files (PUF) with information from Medicare Carrier claims. The CMS BSA Carrier Line...

  16. Stand alone photovoltaic systems: guarantee of results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This study aims to provide a guarantee of results for system performance for users of stand-alone photovoltaic (PV) systems, which have no back-up generator. The appropriate main performance criterion for PV systems is that a specified load is supplied with power either continuously or intermittently whenever the load requires power. A methodology to evaluate the power availability of stand-alone PV systems has been developed as part of the project, which encompasses power losses due to weather variations. The guarantee of results produced allows users to compare system designs from different manufacturers. (UK)

  17. United States housing, 2012

    Science.gov (United States)

    Delton Alderman

    2013-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.

  18. Developing a mobile stand alone photovoltaic generator

    International Nuclear Information System (INIS)

    Soler-Bientz, R.; Ricalde-Cab, L.O.; Solis-Rodriguez, L.E.

    2006-01-01

    This paper describes a recent work developed to create a mobile stand alone photovoltaic generator that can be easily relocated in remote areas to evaluate the feasibility of photovoltaic energy applications. A set of sensors were installed to monitor the electric current and voltage of the energy generated, the energy stored and the energy used by the loads that may be connected to the system. Other parameters like solar radiations (both on the horizontal and on the photovoltaic generation planes) and temperatures (of both the environment and the photovoltaic module) were monitored. This was done while considering the important role of temperature in the photovoltaic module performance. Finally, a measurement and communication hardware was installed to interface the system developed with a conventional computer. In this way, the performance of the overall system in real rural conditions could be evaluated efficiently. Visual software that reads, visualizes and saves the data generated by the system was also developed by means of the LabVIEW programming environment

  19. Stand-alone induction generators for small water power schemes

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Adam [Intermediate Technology Development Group, Rugby (United Kingdom); Smith, Nigel [Smith Associates, Nottingham (United Kingdom)

    1996-04-01

    Conventional technology for isolated power generation is the synchronous generator. Using stand-alone induction generators has proved to have tremendous advantages in remote regions of developing countries, where electricity has significant social benefits. (author)

  20. Basic Stand Alone Medicare DME Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Durable Medical Equipment (DME) Line Items Public Use Files (PUF) with information from Medicare DME claims. The...

  1. Basic Stand Alone Skilled Nursing Facility Beneficiary PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Skilled Nursing Facility (SNF) Beneficiary Public Use Files (PUF) with information from Medicare SNF claims. The...

  2. Chapter 2: Stand-alone Applications - TOPCAT

    Science.gov (United States)

    Miller, C. J.

    Tool for OPerations on Catalogues And Tables or TOPCAT is a graphical viewer for table data. It offers a variety of ways to work with data tables, including a browser for the cell data, viewers for information about table and column metadata, dataset visualization, and even analysis. We discuss a small subset of TOPCAT's functionalities in this chapter. TOPCAT was originally developed as part of the Starlink program in the United Kingdom. It is now maintained by AstroGrid. The program is written in pure Java and available under the GNU General Public License. It is available for download and a version is included in the software distribution accompanying this book. TOPCAT is a GUI interface on top of the STIL library. A command line interface to this library, STILTS, described in Chapter 21 provides scriptable access to many of the capabilities described here. The purpose of this tutorial is to provide an overview of TOPCAT to the novice user. The best place to look for and learn about TOPCAT is the web page maintained by Mark B. Taylor. There, TOPCAT documentation is provided in HTML, PDF, via screen shots, etc. In this chapter we take the user through a few examples that give the general idea of how TOPCAT works. The majority of the functionality of TOPCAT is not included in this short tutorial. Our goal in this tutorial is to lead the reader through an exercise that would result in a publication quality figure (e.g. for a journal article). Specifically, we will use TOPCAT to show how the color-magnitude relation of a galaxy cluster compares to that of all galaxies in the Sloan Digital Sky Survey (York et al. 2000). This diagnostic is used not only in cluster finding, but its linear fit can provide insight into the age and/or metallicity of the oldest galaxies in galaxy clusters (which are some of the oldest galaxies in the Universe). The data we need for this exercise are: 1) the entire spectroscopic galaxy catalog from the SDSS, with galaxy positions, galaxy

  3. Stand-alone version of the 11kW Gaia wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.

    2004-01-01

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of thefast controllers of the unit. Controllers...... assessment and controller design a dynamic performance assessment model has been developed....

  4. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability...

  5. Stand-alone solutions, computer networks and extern communications

    International Nuclear Information System (INIS)

    Tarschisch, H.

    1988-01-01

    The advantages of local networks over stand-alone solutions are presented. Of the local networks (LAN), two are presently at the center of attention: the bus and the ring. ETHERNET and the IBM-Token-Ring are described as typical examples. Access to public networks, especially TELEPAC and ISDN, is discussed. 12 figs

  6. Ampere hour method of sizing a stand alone photovoltaic system ...

    African Journals Online (AJOL)

    Stand-alone photovoltaic power systems are natural options for application in electrification of remote areas which are not served by the grid electricity supply system. An ampere-hour ... Sizing of the balance-of-system were carefully handled to avoid undersizing or oversizing and subsequent variation in supply reliability.

  7. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.

    2001-01-01

    are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model(KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program......This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risø National Laboratory. The work has been supported by the Danish Ministry ofEnergy, as a part of the activities in the Solar...... Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery...

  8. Optimal sizing method for stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Groumpos, P P; Papageorgiou, G

    1987-01-01

    The total life-cycle cost of stand-alone photovoltaic (SAPV) power systems is mathematically formulated. A new optimal sizing algorithm for the solar array and battery capacity is developed. The optimum value of a balancing parameter, M, for the optimal sizing of SAPV system components is derived. The proposed optimal sizing algorithm is used in an illustrative example, where a more economical life-cycle cost has bene obtained. The question of cost versus reliability is briefly discussed.

  9. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  10. Size-Prediction Analysis for Stand-Alone Photovoltaic System

    International Nuclear Information System (INIS)

    Erusiafe, N. E.; Chendo, M. A. C.

    2002-01-01

    The cost - effectiveness of photovoltaic (PV) generator depends, among others, on its ability to satisfy energy demand and the cost of achieving this. In this work a step - by - step procedure for predicting the size of the main components of a stand - alone PV system (array and storage) is presented. The results yield an expression which can he used lo determine the size of both components at optimum cost and desired reliability. The result from this work compare favourably with some earlier works in that, the system sizes shows some degree of agreement

  11. Availability model of stand-alone photovoltaic system

    Science.gov (United States)

    Mazurek, G.

    2017-08-01

    In this paper we present a simple, empirical model of stand-alone photovoltaic power system availability. The model is a final result of five-year long studies and ground measurements of solar irradiation carried out in Central Europe. The obtained results facilitate sizing of PV modules that have to be installed with taking into account system's availability level in each month of a year. The model can be extended to different geographical locations, with help of local meteorological data or solar irradiation datasets derived from satellite measurements.

  12. Future UK markets for stand-alone renewable energy systems

    International Nuclear Information System (INIS)

    Paish, O.

    1999-01-01

    A study to identify and quantify the market for stand-alone renewable energy supplies of power (photovoltaics, wind and micro-hydro electricity systems) was described. The study focused on small systems, generally less than a few kW installed capacity. It was suggested that in the UK, the emphasis on grid-connected renewable energy technologies (RETs) has blurred the fact that it is 'off-grid' renewable systems that can offer more immediate real commercial markets for the renewables business. With the likelihood of a significant increase in demand for renewables world wide over the next ten years, the UK needs to make a special effort to become involved

  13. Benchmarking the Collocation Stand-Alone Library and Toolkit (CSALT)

    Science.gov (United States)

    Hughes, Steven; Knittel, Jeremy; Shoan, Wendy; Kim, Youngkwang; Conway, Claire; Conway, Darrel J.

    2017-01-01

    This paper describes the processes and results of Verification and Validation (VV) efforts for the Collocation Stand Alone Library and Toolkit (CSALT). We describe the test program and environments, the tools used for independent test data, and comparison results. The VV effort employs classical problems with known analytic solutions, solutions from other available software tools, and comparisons to benchmarking data available in the public literature. Presenting all test results are beyond the scope of a single paper. Here we present high-level test results for a broad range of problems, and detailed comparisons for selected problems.

  14. Enhanced current and voltage regulators for stand-alone applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback decoupling permits to achieve a better dynamic response for Voltage Source in stand-alone applications. The design of current and voltage regulators is performed in the discrete-time domain since it provides better accuracy and allows direct pole placement. As the attainable...... bandwidth of the current loop is mainly limited by computational and PWM delays, a lead compensator structure is proposed to overcome this limitation. The design of the voltage regulator is based on the Nyquist criterion, verifying to guarantee a high sensitivity peak. Discrete-time domain implementation...

  15. Hydrogen Gas Production in a Stand-Alone Wind Farm

    Directory of Open Access Journals (Sweden)

    M. Naziry Kordkandy

    2017-04-01

    Full Text Available This paper is analyzing the operation of a stand-alone wind farm with variable speed turbines, permanent magnet synchronous generators (PMSG and a system for converting wind energy during wind speed variations. On this paper, the design and modeling of a wind system which uses PMSG’s to provide the required power of a hydrogen gas electrolyzer system, is discussed. This wind farm consists of three wind turbines, boost DC-DC converters, diode full bridge rectifiers, permanent magnet synchronous generators, MPPT control and a hydrogen gas electrolyzer system. The MPPT controller based on fuzzy logic is designed to adjust the duty ratio of the boost DC-DC converters to absorb maximum power. The proposed fuzzy logic controller assimilates, with (PSF MPPT algorithm which generally used to absorb maximum power from paralleled wind turbines and stores it in form of hydrogen gas. The system is modeled and its behavior is studied using the MATLAB software.

  16. Magnetic field measurements near stand-alone transformer stations.

    Science.gov (United States)

    Kandel, Shaiela; Hareuveny, Ronen; Yitzhak, Nir-Mordechay; Ruppin, Raphael

    2013-12-01

    Extremely low-frequency (ELF) magnetic field (MF) measurements around and above three stand-alone 22/0.4-kV transformer stations have been performed. The low-voltage (LV) cables between the transformer and the LV switchgear were found to be the major source of strong ELF MFs of limited spatial extent. The strong fields measured above the transformer stations support the assessment method, to be used in future epidemiological studies, of classifying apartments located right above the transformer stations as highly exposed to MFs. The results of the MF measurements above the ground around the transformer stations provide a basis for the assessment of the option of implementing precautionary procedures.

  17. Integral type small PWR with stand-alone safety

    International Nuclear Information System (INIS)

    Makihara, Yoshiaki

    2001-01-01

    A feasibility study is achieved on an integral type small PWR with stand-alone safety. It is designed to have the following features. (1) The coolant does not leak out at any accidental condition. (2) The fuel failure does never occur while it is supposed on the large scale PWR at the design base accident. (3) At any accidental condition the safety is secured without any support from the outside (stand-alone safety secure). (4) It has self-regulating characteristics and easy controllability. The above features can be satisfied by integrate the steam generator and CRDM in the reactor vessel while the pipe line break has to be considered on the conventional PWR. Several counter measures are planned to satisfy the above features. The economy feature is also attained by several simplifications such as (1) elimination of main coolant piping and pressurizer by the integration of primary cooling system and self-pressurizing, (2) elimination of RCP by application of natural circulating system, (3) elimination of ECCS and accumulator by application of static safety system, (4) large scale volume reduction of the container vessel by application of integrated primary cooling system, (5) elimination of boric acid treatment by deletion of chemical shim. The long operation period such as 10 years can be attained by the application of Gd fuel in one batch refueling. The construction period can be shortened by the standardizing the design and the introduction of modular component system. Furthermore the applicability of the reduced modulation core is also considered. (K. Tsuchihashi)

  18. A Simple Sizing Algorithm for Stand-Alone PV/Wind/Battery Hybrid Microgrids

    Directory of Open Access Journals (Sweden)

    Jing Li

    2012-12-01

    Full Text Available In this paper, we develop a simple algorithm to determine the required number of generating units of wind-turbine generator and photovoltaic array, and the associated storage capacity for stand-alone hybrid microgrid. The algorithm is based on the observation that the state of charge of battery should be periodically invariant. The optimal sizing of hybrid microgrid is given in the sense that the life cycle cost of system is minimized while the given load power demand can be satisfied without load rejection. We also report a case study to show the efficacy of the developed algorithm.

  19. Development of a microprocessor controller for stand-alone photovoltaic power systems

    Science.gov (United States)

    Millner, A. R.; Kaufman, D. L.

    1984-01-01

    A controller for stand-alone photovoltaic systems has been developed using a low power CMOS microprocessor. It performs battery state of charge estimation, array control, load management, instrumentation, automatic testing, and communications functions. Array control options are sequential subarray switching and maximum power control. A calculator keypad and LCD display provides manual control, fault diagnosis and digital multimeter functions. An RS-232 port provides data logging or remote control capability. A prototype 5 kW unit has been built and tested successfully. The controller is expected to be useful in village photovoltaic power systems, large solar water pumping installations, and other battery management applications.

  20. Design of Stand-Alone Hybrid Power Generation System at Brumbun Beach Tulungagung East Java

    Science.gov (United States)

    Rahmat, A. N.; Hidayat, M. N.; Ronilaya, F.; Setiawan, A.

    2018-04-01

    Indonesian government insists to optimize the use of renewable energy resources in electricity generation. One of the efforts is launching Independent Energy Village plan. This program aims to fulfill the need of electricity for isolated or remote villages in Indonesia. In order to support the penetration of renewable energy resources in electricity generation, a hybrid power generation system is developed. The simulation in this research is based on the availability of renewable energy resources in Brumbun beach, Tulungagung, East Java. Initially, the electricity was supplied through stand-alone electricity generations which are installed at each house. Hence, the use of electricity between 5 p.m. – 9 p.m. requires high operational costs. Based on the problem above, this research is conducted to design a stand-alone hybrid electricity generation system, which may consist of diesel, wind, and photovoltaic. The design is done by using HOMER software to optimize the use of electricity from renewable resources and to reduce the operation of diesel generation. The combination of renewable energy resources in electricity generation resulted in NPC of 44.680, COE of 0,268, and CO2 emissions of 0,038 % much lower than the use of diesel generator only.

  1. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  2. A control strategy for PV stand-alone applications

    International Nuclear Information System (INIS)

    Slouma, S; Baccar, H

    2015-01-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system

  3. Improving efficiency of a regional stand alone bone bank.

    Science.gov (United States)

    Warnock, Jonathan M; Rowan, Clare H; Davidson, Helen; Millar, Ciara; McAlinden, M Gavan

    2016-03-01

    The introduction of a stand-alone Bone Bank in our Regional Orthopaedic Hospital has improved the availability of femoral head allograft. Benninger et al. (Bone Joint J 96-B:1307-1311, 2014), demonstrated their institutions bank to be cost effective despite a 30 % discard rate for harvested allograft. We sought to audit our own discard rates and subsequent cost-effectiveness of our bone bank. Donor recruitment. Before approaching a potential donor, our establishment's nurse specialists review their clinical notes and biochemical laboratory results, available on a regional Electronic Care Records. They view femoral head architecture on radiographs against set criteria, Patient Archive and Communication system (SECTRA, Sweden). In total 1383 femoral heads were harvested, 247 were discarded giving an overall rate of 17.9 %. The most common reasons for discard of harvested graft was a positive microbiology/bacteriology result, n = 96 (38.9 %). After a rise in discard rates in 2007, we have steadily reduced our discard rates since 2006/2007 (28.2 %), 2008/2009 (17 %), 2010/2011 (14.8 %), and finally to 10.3 % in 2012/2013. In the current financial year, our cost to harvest, test, store and release a femoral head is £ 610. With a structured donor recruitment process and unique pre-operative radiographic analysis we have successfully reduced our discard rates bi-annually making our bone bank increasingly cost-effective.

  4. The Stand-alone Heliostat; El Heliostato Autonomo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Navajas, G.; Egea Gea, A. [Ciemat. Madrid (Spain)

    2000-07-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-m''2, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24 Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modern working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modern. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs.

  5. The Stand-alone Heliostat; El Heliostato Autonomo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Navajas, G; Egea Gea, A [Ciemat. Madrid (Spain)

    2000-07-01

    The first Autonomous Heliostat has been developed by CIEMAT at PSA facilities in Almeria. This heliostat is an innovative approach to reducing the civil engineering work costs in heliostat fields of central tower plants. Channels, cables and other electric elements have been eliminated in the new heliostat. Thus, one 70-m''2, classical T glass/metal heliostat has been adapted to include all the new stand-alone concept components. A PV system is able to drive two sun-tracking DC motors between 5 and 24 Vdc, 0 and 15A. The heliostat communicates with the control room 400-m away by using a radio-modern working at 9600 baud. An anemometer, a wind switcher, light and ambient temperature sensors have been installed on the heliostat for self-protection decision-making. A PV panel integrated into the heliostat reflecting surface, eliminates cabling and other elements required for a conventional power supply. Communication lines between master control and local control have been replaced by radio-modern. Testing has validated the technical feasibility of the prototype and quantified the real consumption and efficiencies of new elements. The extra costs produced by the autonomous concepts are compared with the cost of civil work in conventional heliostat field. (Author) 8 refs.

  6. Robust Power Management Control for Stand-Alone Hybrid Power Generation System

    International Nuclear Information System (INIS)

    Kamal, Elkhatib; Adouane, Lounis; Aitouche, Abdel; Mohammed, Walaa

    2017-01-01

    This paper presents a new robust fuzzy control of energy management strategy for the stand-alone hybrid power systems. It consists of two levels named centralized fuzzy supervisory control which generates the power references for each decentralized robust fuzzy control. Hybrid power systems comprises: a photovoltaic panel and wind turbine as renewable sources, a micro turbine generator and a battery storage system. The proposed control strategy is able to satisfy the load requirements based on a fuzzy supervisor controller and manage power flows between the different energy sources and the storage unit by respecting the state of charge and the variation of wind speed and irradiance. Centralized controller is designed based on If-Then fuzzy rules to manage and optimize the hybrid power system production by generating the reference power for photovoltaic panel and wind turbine. Decentralized controller is based on the Takagi-Sugeno fuzzy model and permits us to stabilize each photovoltaic panel and wind turbine in presence of disturbances and parametric uncertainties and to optimize the tracking reference which is given by the centralized controller level. The sufficient conditions stability are formulated in the format of linear matrix inequalities using the Lyapunov stability theory. The effectiveness of the proposed Strategy is finally demonstrated through a SAHPS (stand-alone hybrid power systems) to illustrate the effectiveness of the overall proposed method. (paper)

  7. Stand-alone version of the 11kW Gaia wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Rosas, P.A.C.; Teodorescu, R.; Blaabjerg, F.

    2004-09-15

    This report describes the development of a stand-alone version of the 11kW Gaia wind turbine. Various possible configurations are investigated and a configuration using a back-to-back converter is chosen. A model is developed for controller design of the fast controllers of the unit. Controllers are designed and a prototype is built for testing. The report documents the performance of the prototype through measurements done on the full scale prototype installed in a test facility where it has been tested both as a standalone unit and in parallel with a diesel genset. For system wide power quality assessment and controller design a dynamic performance assessment model has been developed. (au)

  8. R and D into stand-alone PV systems for export

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The current status of photovoltaic (PV) technology is reviewed for systems to provide electricity where mains supplies are unavailable, known as stand-alone PV systems. Typical applications and experiences with installed stand-alone systems are described. Economic issues and barriers to the wide use of PV systems are also examined. (UK)

  9. Power quality improvement of a stand-alone power system subjected to various disturbances

    Science.gov (United States)

    Lone, Shameem Ahmad; Mufti, Mairaj Ud-Din

    In wind-diesel stand-alone power systems, the disturbances like random nature of wind power, turbulent wind, sudden changes in load demand and the wind park disconnection effect continuously the system voltage and frequency. The satisfactory operation of such a system is not an easy task and the control design has to take in to account all these subtleties. For maintaining the power quality, generally, a short-term energy storage device is used. In this paper, the performance of a wind-diesel system associated with a superconducting magnetic energy storage (SMES) system is studied. The effect of installing SMES at wind park bus/load bus, on the system performance is investigated. To control the exchange of real and reactive powers between the SMES unit and the wind-diesel system, a control strategy based on fuzzy logic is proposed. The dynamic models of the hybrid power system for most common scenarios are developed and the results presented.

  10. Energy management system for stand-alone diesel-wind-biomass microgrid with energy storage system

    International Nuclear Information System (INIS)

    Wang, Chengshan; Liu, Yixin; Li, Xialin; Guo, Li; Qiao, Lei; Lu, Hai

    2016-01-01

    An energy management system for stand-alone microgrid composed of diesel generators, wind turbine generator, biomass generator and an ESS (energy storage system) is proposed in this paper. Different operation objectives are achieved by a hierarchical control structure with different time scales. Firstly, the optimal schedules of the diesel generators, wind turbine generator, biomass generator and ESS are determined fifteen minutes ahead according to the super short-term forecast of load and wind speed in the optimal scheduling layer. Comprehensive analysis which takes the uncertainty of load and wind speed into account is conducted in this layer to minimize the operation cost of the system and ensure a desirable range of the state of charge of the ESS. Secondly, the operation points of each unit are regulated dynamically to guarantee real-time power balance and safety range of diesel generation in the real-time control layer, based on which the response capability when suffering significant forecast deviation and other emergency issues, e.g. sudden load-up can be improved. Finally, the effectiveness of the proposed energy management strategy is verified on an RT-Lab based real-time simulation platform, and the economic performances with different types of ESS are analyzed as well. - Highlights: • A hierarchical control strategy is proposed for a stand-alone microgrid. • The uncertainties of load and wind speed have been considered. • Better economic performance and high reliability of the system can be achieved. • The influences of different energy storage systems have been analyzed.

  11. Methanol production via pressurized entrained flow biomass gasification – Techno-economic comparison of integrated vs. stand-alone production

    International Nuclear Information System (INIS)

    Andersson, Jim; Lundgren, Joakim; Marklund, Magnus

    2014-01-01

    The main objective with this work was to investigate techno-economically the opportunity for integrated gasification-based biomass-to-methanol production in an existing chemical pulp and paper mill. Three different system configurations using the pressurized entrained flow biomass gasification (PEBG) technology were studied, one stand-alone plant, one where the bark boiler in the mill was replaced by a PEBG unit and one with a co-integration of a black liquor gasifier operated in parallel with a PEBG unit. The cases were analysed in terms of overall energy efficiency (calculated as electricity-equivalents) and process economics. The economics was assessed under the current as well as possible future energy market conditions. An economic policy support was found to be necessary to make the methanol production competitive under all market scenarios. In a future energy market, integrating a PEBG unit to replace the bark boiler was the most beneficial case from an economic point of view. In this case the methanol production cost was reduced in the range of 11–18 Euro per MWh compared to the stand-alone case. The overall plant efficiency increased approximately 7%-units compared to the original operation of the mill and the non-integrated stand-alone case. In the case with co-integration of the two parallel gasifiers, an equal increase of the system efficiency was achieved, but the economic benefit was not as apparent. Under similar conditions as the current market and when methanol was sold to replace fossil gasoline, co-integration of the two parallel gasifiers was the best alternative based on received IRR. - Highlights: • Techno-economic results regarding integration of methanol synthesis processes in a pulp and paper mill are presented. • The overall energy efficiency increases in integrated methanol production systems compared to stand-alone production units. • The economics of the integrated system improves compared to stand-alone alternatives. • Tax

  12. Clinical outcome of stand-alone ALIF compared to posterior instrumentation for degenerative disc disease

    DEFF Research Database (Denmark)

    Udby, Peter M.; Bech-Azeddine, Rachid

    2015-01-01

    The objective of the article was to: a) present results from a case cohort pilot study comparing stand-alone ALIF and TLIF and, b) review the literature on studies comparing the clinical outcome of stand-alone ALIF with posterior instrumentation including TLIF or PLIF, in patients with disabling...... low back pain resulting from degenerative disc disease. ALIF surgery has previously been linked with certain high risk complications and unfavorable long term fusion results. Newer studies suggest that stand-alone ALIF can possibly be advantageous compared to other types of posterior instrumented...

  13. Design of a reliable and low-cost stand-alone micro hydropower station

    Energy Technology Data Exchange (ETDEWEB)

    Kusakana, K.; Munda, J.L. [Tshwane Univ. of Technology, Pretoria (South Africa)

    2008-07-01

    A stand-alone micro-hydropower station was presented. The plant was comprised of a squirrel cage induction machine coupled to a Kaplan water turbine. Power converters were used to control the variable frequency and voltage outputs of the generator caused by variations in water flow. The hydropower plant was installed a farm in the Kwazulu-Natal region of South Africa, and was designed to provide electricity in relation to the low power demand of users in the region as well as according to the site's hydrology and topology. Load forecasts for the 8 houses using the system were conducted. A generator with a higher output than the average power needed to feed the load was selected in order to ensure load supply during peak demand. The system was designed to shore energy generated during off-peak periods in batteries. An AC-DC-AC converter was used as an interface between the generator and the load in order to ensure voltage and frequency stabilization. Simulations of plant components were conducted to demonstrate output power supply during water flow variations. Results of the modelling study indicated that power converters are needed to stabilize generator outputs. The hydropower design is a cost-effective means of supplying power to low-income households. 10 refs., 2 tabs., 7 figs.

  14. Simulation of stand alone PV system; Dokuritsugata taiyoko hatsuden system no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, H; Ogawa, H; Sekii, Y [Chiba Institute of Technology, Chiba (Japan); Tsuda, I; Nozaki, K [Electrotechnical Laboratory, Tsukuba (Japan); Kurokawa, K [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1996-10-27

    In order to evaluate the simulation results of a photovoltaic power generation system, an operation simulation was carried out using the actual measured data of a stand alone PV system in Miyakojima, Okinawa Prefecture, so as to make a comparison with the actual operation data. The electric power was supplied to 250 houses and primary/junior high schools in the surrounding villages, which had an average demand load of approximately 90kw and the maximum of approximately 200kw. The power was supplied through the PV power generation in the duration of the sunshine, with an excess power charged in storage batteries and then supplied from the batteries at night. The array capacity was made 750kWp, the output current and storage batteries being characteristic type with an actual efficiency curve used for the inverter. The weather data used were the actual inclined insolation quantity and the outside air temperature data for a period of one month of November. The power charged in excess of 100% in the batteries was termed as an overflow power. With the charging condition 30% or less, a diesel generator was run for a rated operation for one hour, the power of which was termed as a backup power. As a result, the simulation was found nearly in agreement with the actual measurements. 5 refs., 7 figs., 2 tabs.

  15. Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems; TOPICAL

    International Nuclear Information System (INIS)

    DeBlasio, R.; Durand, S.; Hansen, R.; Hutchinson, P.; Kroposki, B.; McNutt, P.; Rosenthal, A.; Thomas, M.

    1999-01-01

    This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested

  16. She stands alone: Pakistani woman film director, Shireen Pasha.

    Science.gov (United States)

    Mustafa, A

    1995-01-01

    USAID and the government, were "Before It's Too Late" and "Only One Way." Both deal with resource issues and the environment. She is currently director of her own film house, The Film Makers, in Lahore. After graduating from the National College of Arts in 1968, she furthered her education in the US in the history of art.

  17. United States housing, first quarter 2013

    Science.gov (United States)

    Delton Alderman

    2014-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing under construction, and housing completions for single and multifamily units, and sales and construction. This report will be updated regularly.

  18. A Control Approach and Supplementary Controllers for a Stand-Alone System with Predominance of Wind Generation

    Directory of Open Access Journals (Sweden)

    Tiago Lukasievicz

    2018-02-01

    Full Text Available This paper proposes a control approach and supplementary controllers for the operation of a hybrid stand-alone system composed of a wind generation unit and a conventional generation unit based on synchronous generator (CGU. The proposed controllers allow the islanded or isolated operation of small power systems with predominance of wind generation. As an advantage and a paradigm shift, the DC-link voltage of the wind unit is controlled by means of a conventional synchronous generator connected to the AC grid of the system. Two supplementary controllers, added to a diesel generator (DIG and to a DC dump load (DL, are proposed to control the DC-link voltage. The wind generation unit operates in V-f control mode and the DIG operates in PQ control mode, which allows the stand-alone system to operate either in wind-diesel (WD mode or in wind-only (WO mode. The strong influence of the wind turbine speed variations in the DC-link voltage is mitigated by a low-pass filter added to the speed control loop of the wind turbine. The proposed control approach does not require the use battery bank and ultra-capacitor to control the DC-link voltage in wind generation units based on fully rated converter.

  19. Comparative analysis of distributed MPPT controllers for partially shaded stand alone photovoltaic systems

    International Nuclear Information System (INIS)

    Muthuramalingam, M.; Manoharan, P.S.

    2014-01-01

    Highlights: • Analyzes the performance of ANN and ANFIS MPPT algorithms by stand alone PV system. • ISSBC with ANFIS can provide the overall efficiency higher than ANN. • CHBMLI integrate with SHE ANN modulation technique improve output voltage quality. • Simulation and hardware results show the ANFIS algorithm efficient than ANN algorithm. - Abstract: This paper presents a unique combination of an interleaved soft switched boost converter (ISSBC) run by a set of two photovoltaic panel (PV) with a distributed MPPT, suitable to guarantee MPPT even under partial shadowed conditions, managed by an adaptive neuro fuzzy inference system trained by the training data derived from a particle swarm optimization (PSO–ANFIS) unit. The ISSBC is followed by a, single phase cascaded H bridge five-level inverter (CHI) driven by the individual DC outputs of the ISSBC, with selective harmonic elimination scheme to eliminate typically the seventh order harmonics. A comparison of different intelligent distributed maximum power point tracking (MPPT) algorithms for photovoltaic (PV) system under partial shadow conditions is carried out. The use of the ISSBC guarantees mitigation of ripple and it is meant to handle higher currents with minimal switching losses. Simulation was carried out in the Matlab Simulink environment and an experimental verification with a scaled down model validated the proposed scheme. It has been thus established, by both simulation and experimental verification, that the PSO–ANFIS model of distributed MPPT scheme of control outperforms other schemes of control for MPPT

  20. Stand-Alone Photovoltaic System Assessment in Warmer Urban Areas in Mexico

    Directory of Open Access Journals (Sweden)

    Alberto-Jesus Perea-Moreno

    2018-01-01

    Full Text Available The aim of this study is to examine the possibility of using a stand-alone photovoltaic system (SAPVS for electricity generation in urban areas in Southern Mexico. In Mexico, an urban area is defined as an area where more than 2500 inhabitants live. Due to constant migration from the countryside to the cities, the number of inhabitants of urban localities has been increasing. Global horizontal irradiation (GHI data were recorded every 10 min during 2014–2016 in Coatzacoalcos in the state of Veracruz located on 18°08′09″ N and 94°27′48″ W. In this study, batteries represented 77% of the total cost, 12 PV panels of 310 W could export 5.41 MWh to the grid, and an inverter with an integrated controller and charger was selected, which decreased the initial cost. The city of Coatzacoalcos was chosen because the average annual temperature is 28°, with an average relative humidity of 75% and an average irradiance of 5.3 kWh/m2/day. An emission factor 0.505 tCO2/MWh of greenhouse gases (GHG were obtained, based on the power system, the reduction of net annual GHG would be 11 tCO2 and a financial revenue of 36.951 × 103 $/tCO2 would be obtained. Financial parameters such as a 36.3% Internal Rate Return (IRR and 3.4 years payback show the financial viability of this investment. SAPVSs in urban areas in Mexico could be a benefit as long as housing has a high consumption of electricity.

  1. Stand-alone photovoltaic systems in the Netherlands. Evaluation of the market introduction

    International Nuclear Information System (INIS)

    Cloin, J.; Van Dijk, A.L.; Westra, C.A.

    1999-08-01

    The policy followed for stand-alone PV systems in the Netherlands is evaluated for the period 1997-1998. The world-wide powerful growth of the PV industry is not being followed by the increase in volume of implemented stand-alone PV systems in the Netherlands. This leads to the question whether the Dutch policy to stimulate stand-alone PV systems is effective. Recommendations on the use of communication as a strategic instrument are given, including the drawing up of a marketing plan. Other recommendations include increased transparency in the application for subsidies and a pro-active role of the Netherlands Agency for Energy and the Environment (Novem) in the contact with relevant market parties. The increased focus on product development aimed at the environmental benefits and general reliability of PV systems is recommended. 38 refs

  2. Stand-alone wind system with Vanadium Redox Battery energy storage

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Barote, L.; Weissbach, R.

    2008-01-01

    Energy storage devices are required for power balance and power quality in stand alone wind energy systems. A Vanadium Redox Flow Battery (VRB) system has many features which make its integration with a stand-alone wind energy system attractive. This paper proposes the integration of a VRB system...... with a typical stand-alone wind energy system during wind speed variation as well as transient performance under variable load. The investigated system consists of a variable speed wind turbine with permanent magnet synchronous generator (PMSG), diode rectifier bridge, buck-boost converter, bidirectional charge...... controller, transformer, inverter, ac loads and VRB (to store a surplus of wind energy and to supply power during a wind power shortage). The main purpose is to supply domestic appliances through a single phase 230V, 50Hz inverter. Simulations are accomplished in order to validate the stability of the supply....

  3. Connecting embedded and stand-alone peer mentoring models to enhance student engagement

    Directory of Open Access Journals (Sweden)

    Rhys Cooper

    2018-03-01

    Full Text Available This paper outlines the Trident Student Mentoring Program that runs in the College of Engineering at Victoria University, Melbourne, Australia. The program offers both embedded and stand-alone models of peer mentoring services to the same cohort of first-year students. It shows that by forming strong links between these two types of peer mentoring models, the inherent challenges of both, such as low attendance rates in stand-alone models and short periods of peer to peer time in embedded models, are mitigated.

  4. Sensorless direct voltage control of the stand-alone brushless doubly-fed generator

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The conventional stand-alone brushless doubly-fed generator (BDFG) control strategies need the feedback from the rotor position or speed sensors, which can reduce system reliability and increase the cost and axial volume of the machine. In this paper, a sensorless direct voltage control (DVC) str......) strategy is presented for the stand-alone BDFG. The satisfactory dynamic performance is verified by experimental results under four kinds of typical operation conditions. Besides, the proposed control strategy is robust due to no generator parameters being required....

  5. Linguistic and Structural Analyses of Stand-Alone Literature Reviews: Seventy-Five Years of Change

    Science.gov (United States)

    Wright, Heidi Rachel

    2016-01-01

    The purpose of this dissertation is to offer a multifaceted overview of stand-alone literature reviews. These texts, literature reviews published unattached to research articles, have existed for centuries but remained largely unstudied by linguists. Thus, the goal of this project is to present these reviews' situational, grammatical, and…

  6. Assessment of Stand-Alone Displays for Time Management in a Creativity-Driven Learning Environment

    DEFF Research Database (Denmark)

    Frimodt-Møller, Søren

    2017-01-01

    This paper considers the pros and cons of stand-alone displays, analog (e.g. billboards, blackboards, whiteboards, large pieces of paper etc.) as well as digital (e.g. large shared screens, digital whiteboards or similar), as tools for time management processes in a creativity-driven learning...

  7. A maximum power point tracking scheme for a 1kw stand-alone ...

    African Journals Online (AJOL)

    A maximum power point tracking scheme for a 1kw stand-alone solar energy based power supply. ... Nigerian Journal of Technology ... A method for efficiently maximizing the output power of a solar panel supplying a load or battery bus under ...

  8. Use of Super-Capacitor to Enhance Charging Performance of Stand-Alone Solar PV System

    KAUST Repository

    Huang, B. J.; Hsu, P. C.; Ho, P. Y

    2011-01-01

    Introduction: The battery charging performance in a stand-alone solar PV system affects the PV system efficiency and the load operating time. The New Energy Center of National Taiwan University has been devoted to the development of a PWM charging

  9. Environmental/Climatic Effect on Stand-Alone Solar Energy Supply ...

    African Journals Online (AJOL)

    This paper investigates the climatic eects and environmental variations on the performance of a stand-alone photovoltaic system. The eects of partial shading with dierent climate conditions and load resistance variations were examined. A survey of some of the work done in this eld of environmental eect on solar panel was ...

  10. 11kW stand alone wind turbine based on proven wind turbine

    DEFF Research Database (Denmark)

    Bindner, H.; Wodstrup, J.; Andersen, J.

    2004-01-01

    and enable control of frequency and voltage independently on both the grid side and the generator side. The prototype has been installed at Risø. The paper will present results from test runs of the system both operating stand-alone supplying a single load and in parallel operation with a diesel genset....

  11. Modelling of fluid-solid interaction using two stand-alone codes

    CSIR Research Space (South Africa)

    Grobler, Jan H

    2010-01-01

    Full Text Available A method is proposed for the modelling of fluid-solid interaction in applications where fluid forces dominate. Data are transferred between two stand-alone codes: a dedicated computational fluid dynamics (CFD) code capable of free surface modelling...

  12. Comparison of pulp-mill-integrated hydrogen production from gasified black liquor with stand-alone production from gasified biomass

    International Nuclear Information System (INIS)

    Andersson, E.; Harvey, S.

    2007-01-01

    When gasified black liquor is used for hydrogen production, significant amounts of biomass must be imported. This paper compares two alternative options for producing hydrogen from biomass: (A) pulp-mill-integrated hydrogen production from gasified back liquor; and (B) stand-alone production of hydrogen from gasified biomass. The comparison assumes that the same amount of biomass that is imported in Alternative A is supplied to a stand-alone hydrogen production plant and that the gasified black liquor in Alternative B is used in a black liquor gasification combined cycle (BLGCC) CHP unit. The comparison is based upon equal amounts of black liquor fed to the gasifier, and identical steam and power requirements for the pulp mill. The two systems are compared on the basis of total CO 2 emission consequences, based upon different assumptions for the reference energy system that reflect different societal CO 2 emissions reduction target levels. Ambitions targets are expected to lead to a more CO 2 -lean reference energy system, in which case hydrogen production from gasified black liquor (Alternative A) is best from a CO 2 emissions' perspective, whereas with high CO 2 emissions associated with electricity production, hydrogen from gasified biomass and electricity from gasified black liquor (Alternative B) is preferable. (author)

  13. Stand-Alone Solar Organic Rankine Cycle Water Pumping System and Its Economic Viability in Nepal

    Directory of Open Access Journals (Sweden)

    Suresh Baral

    2015-12-01

    Full Text Available The current study presents the concept of a stand-alone solar organic Rankine cycle (ORC water pumping system for rural Nepalese areas. Experimental results for this technology are presented based on a prototype. The economic viability of the system was assessed based on solar radiation data of different Nepalese geographic locations. The mechanical power produced by the solar ORC is coupled with a water pumping system for various applications, such as drinking and irrigation. The thermal efficiency of the system was found to be 8% with an operating temperature of 120 °C. The hot water produced by the unit has a temperature of 40 °C. Economic assessment was done for 1-kW and 5-kW solar ORC water pumping systems. These systems use different types of solar collectors: a parabolic trough collector (PTC and an evacuated tube collector (ETC. The economic analysis showed that the costs of water are $2.47/m3 (highest and $1.86/m3 (lowest for the 1-kW system and a 150-m pumping head. In addition, the cost of water is reduced when the size of the system is increased and the pumping head is reduced. The minimum volumes of water pumped are 2190 m3 and 11,100 m3 yearly for 1 kW and 5 kW, respectively. The payback period is eight years with a profitability index of 1.6. The system is highly feasible and promising in the context of Nepal.

  14. Optimum capacity determination of stand-alone hybrid generation system considering cost and reliability

    International Nuclear Information System (INIS)

    Chen, Hung-Cheng

    2013-01-01

    Highlights: ► This paper presents a methodology for the installation capacity optimization. ► Hybrid generation system is optimized by application of adaptive genetic algorithm. ► A cost investigation is made under various conditions and component characteristics. ► The optimization scheme is validated to meet the annual power load demand. -- Abstract: The aim of this work is to present an optimization methodology for the installation capacity of a stand-alone hybrid generation system, taking into consideration the cost and reliability. Firstly, on the basis of derived steady state models of a wind generator (WG), a photovoltaic array (PV), a battery and an inverter, the hybrid generation system is modeled for the purpose of capacity optimization. Secondly, the power system is analyzed for determining both the system structure and the operation control strategy. Thirdly, according to hourly weather database of wind speed, temperature and solar irradiation, annual power generation capacity is estimated for the system match design in order that an annual power load demand can be met. The capacity determination of a hybrid generation system becomes complicated as a result of the uncertainty in the renewable energy together with load demand and the nonlinearity of system components. Aimed at the power system reliability and the cost minimization, the capacity of a hybrid generation system is optimized by application of an adaptive genetic algorithm (AGA) to individual power generation units. A total cost investigation is made under various conditions, such as wind generator power curves, battery discharge depth and the loss of load probability (LOLP). At the end of this work, the capacity of a hybrid generation system is optimized at two installation sites, namely the offshore Orchid Island and Wuchi in Taiwan. The optimization scheme is validated to optimize power capacities of a photovoltaic array, a battery and a wind turbine generator with a relative

  15. Use of appliances in stand-alone PV power supply systems: problems and solutions. Task 3 use of photovoltaic power systems in stand-alone and island applications

    Energy Technology Data Exchange (ETDEWEB)

    Vallve, X.; Gafas, G. [IEA PVPS, Task 3 (Spain); Villoz, M. [IEA PVPS, Task 3 (Switzerland); Wilshaw, A. [IEA PVPS, Task 3 (United Kingdom); Jacquin, P. [IEA PVPS, Task 3 (France)

    2002-09-15

    In Stand-Alone Photovoltaic Systems (SAPV systems), special attention must be paid to the used appliances and loads. Inappropriate loads are very often the origin of PV system malfunction or failure. Start-up power peaks, or reactive power and harmonic distortion can cause system signal instability and protective devices will close the system down. A well-matched load together with a carefully selected choice of appliances can lead to significant savings in terms of reduced need for PV and electricity storage capacity. Conversely, inefficient appliances and processes, standby loads and inappropriate loads will increase the requirement for expensive PV and storage capacity. This paper presents a survey of real cases with load related problems in worldwide applications, their effect on quality and cost of the service and the solutions that were adopted and suggested alternative solutions. One of the main conclusions of the work is the importance to integrate the choice of the appliance while designing the SAPV system. (author)

  16. Hybrid Configuration of Darrieus and Savonius Rotors for Stand-alone Power Systems

    Science.gov (United States)

    Wakui, Tetsuya; Tanzawa, Yoshiaki; Hashizume, Takumi; Nagao, Toshio

    The suitable hybrid configuration of Darrieus lift-type and Savonius drag-type rotors for stand-alone wind turbine-generator systems is discussed using our dynamic simulation model. Two types of hybrid configurations are taken up: Type-A installs the Savonius rotor inside the Darrieus rotor and Type-B installs the Savonius rotor outside the Darrieus rotor. The computed results of the output characteristics and the dynamic behaviors of the system operated at the maximum power coefficient points show that Type-A, which has fine operating behavior to wind speed changes and can be compactly designed because of a shorter rotational shaft, is an effective way for self-controlled stand-alone small-scale systems.

  17. Stand-Alone Microgrid Inverter Controller Design for Nonlinear, Unbalanced Load with Output Transformer

    Directory of Open Access Journals (Sweden)

    Jae-Uk Lim

    2018-04-01

    Full Text Available This paper proposes a technique that compensates for unbalance and nonlinearity in microgrid inverters with power transformers operating in stand-alone mode. When a microgrid inverter is operating in stand-alone mode, providing high-quality power is very important. When an unbalanced, nonlinear load is connected, zero sequence current and negative sequence current occur, which leads to an unbalanced output voltage. This paper examines why the zero sequence component occurs differently depending on the structure of a three-phase transformer connected to the inverter output terminal, and it proposes a method for controlling the zero sequence component. It also uses a resonant controller to remove the harmonics that correspond to the negative sequence component and the nonlinear component. The proposed elements were verified by a Powersim (PSIM simulation.

  18. A Three-Port Topology Comparison for a Low Power Stand-Alone Photovoltaic System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using c...... component stress factor (CSF) is performed, which gives a quantitative measure of the performance of the converter. The candidate topologies are compared to each other according to a defined LED lighting strategy and a solar irradiation profile.......Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using...

  19. Analysis and controller design for stand-alone VSIs in synchronous reference frame

    DEFF Research Database (Denmark)

    Ramezani, Malek; Li, Shuhui; Golestan, Saeed

    2017-01-01

    -by-step graphical analysis and design approach for a three-phase stand-alone VSI system in the dq reference frame, which provides a clear systematic decoupling process to design the inner- and outer-loop current and voltage controllers, respectively. The closed-loop d- and q-axis output impedances of the stand......-alone VSI system by considering the coupling effects between axes are also formulated, modelled, and evaluated. The study investigates how the decoupling and compensating terms added in the current and voltage controllers affect the dynamic performance and output dq impedances of the VSI system. Simulation...... and hardware results verify the effectiveness of the graphic design and analysis strategy....

  20. A new approach for sizing stand alone photovoltaic systems based in neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Hontoria, L.; Aguilera, J. [Universidad de Jaen, Dept. de Electronica, Jaen (Spain); Zufiria, P. [UPM Ciudad Universitaria, Dept. de Matematica Aplicada a las Tecnologias de la Informacion, Madrid (Spain)

    2005-02-01

    Several methods for sizing stand alone photovoltaic (pv) systems has been developed. The more simplistic are called intuitive methods. They are a useful tool for a first approach in sizing stand alone photovoltaic systems. Nevertheless they are very inaccurate. Analytical methods use equations to describe the pv system size as a function of reliability. These ones are more accurate than the previous ones but they are also not accurate enough for sizing of high reliability. In a third group there are methods which use system simulations. These ones are called numerical methods. Many of the analytical methods employ the concept of reliability of the system or the complementary term: loss of load probability (LOLP). In this paper an improvement for obtaining LOLP curves based on the neural network called Multilayer Perceptron (MLP) is presented. A unique MLP for many locations of Spain has been trained and after the training, the MLP is able to generate LOLP curves for any value and location. (Author)

  1. Minimum cost solution of wind–photovoltaic based stand-alone power systems for remote consumers

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Zafirakis, D.; Kavadias, K.

    2012-01-01

    Renewable energy sources (RES) based stand-alone systems employing either wind or solar power and energy storage comprise a reliable energy alternative, on top of conventional diesel-electric generator sets, commonly used by remote consumers. However, such systems usually imply the need for oversizing and considerable energy storage requirements leading to relatively high costs. On the other hand, hybrid configurations that may exploit both wind and solar potential of a given area may considerably reduce energy storage capacity and improve the economic performance of the system. In this context, an integrated techno-economic methodology for the evaluation of hybrid wind–photovoltaic stand-alone power systems is currently developed, aiming at the designation of optimum configurations for a typical remote consumer, using economic performance criteria. For the problem investigation, the developed evaluation model is applied to four representative areas of the Greek territory with different wind potential characteristics in order to obtain optimum configurations on the basis of minimum initial investment, 10-year and 20-year total cost. According to the results obtained, the proposed solution is favorably compared with all other stand-alone energy alternatives, reflecting the ability of hybrid systems to adjust even in areas where the local RES potential is not necessarily of high quality. - Highlights: ► Wind- and PV-stand alone systems often imply use of extreme battery capacity. ► Hybrid wind–PV systems may reduce energy storage requirements and associated costs. ► An optimization methodology is developed, based on economic performance criteria. ► Methodology is applied to four Greek regions of different wind potential. ► Results obtained reflect the hybrid solution's advantages over other alternatives.

  2. Secure stand alone positive personnel identity verification system (SSA-PPIV)

    International Nuclear Information System (INIS)

    Merillat, P.D.

    1979-03-01

    The properties of a secure stand-alone positive personnel identity verification system are detailed. The system is designed to operate without the aid of a central computing facility and the verification function is performed in the absence of security personnel. Security is primarily achieved by means of data encryption on a magnetic stripe badge. Several operational configurations are discussed. Advantages and disadvantages of this system compared to a central computer driven system are detailed

  3. MOSFET Loss Evaluation for a Low-Power Stand-Alone Photovoltaic-LED System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2015-01-01

    This paper presents a performance evaluation and comparison of state-of-the-art low voltage Si MOSFETs for a stand-alone photovoltaic-LED Light to Light (LtL) system. The complete system is formed by two cascaded converters that will be optimized for a determined solar irradiation and LED...... illumination profiles. The comparison is performed based on dynamic characterization and evaluation of the devices energy loss at different current levels....

  4. Stand-Alone Solar Organic Rankine Cycle Water Pumping System and Its Economic Viability in Nepal

    OpenAIRE

    Suresh Baral; Kyung Chun Kim

    2015-01-01

    The current study presents the concept of a stand-alone solar organic Rankine cycle (ORC) water pumping system for rural Nepalese areas. Experimental results for this technology are presented based on a prototype. The economic viability of the system was assessed based on solar radiation data of different Nepalese geographic locations. The mechanical power produced by the solar ORC is coupled with a water pumping system for various applications, such as drinking and irrigation. The thermal ef...

  5. Methodology for the design of a stand-alone photovoltaic power supply

    OpenAIRE

    López Seguel, Julio; Seleme Junior, Seleme Isaac; Donoso-Garcia, Pedro F; Ferreira Morais, Lenin Martins; Cabaleiro Cortizo, Porfirio; Severo Mendes, Marcos A

    2013-01-01

    This paper presents a complete methodology for the design of an autonomous photovoltaic system to maximize the use of solar energy. It is a method that prioritizes the best cost-effective choice at every step of the project. In order to ensure the proper use and extended battery life time, a control strategy for charging the batteries is proposed. Experimental results are provided for a stand-alone photovoltaic system with low electrical power, intended primarily for the illumination and basi...

  6. Modeling, Design and Simulation of Stand-Alone Photovoltaic Power Systems with Battery Storage

    Directory of Open Access Journals (Sweden)

    Abd Essalam BADOUD

    2013-06-01

    Full Text Available Stand alone renewable energy based on photovoltaic systems accompanied with battery storage system are beginning to play an important role over the world to supply power to remote areas. The objective of the study reported in this paper is to elaborate and design a bond graphs model for sizing stand-alone domestic solar photovoltaic electricity systems and simulating the performance of the systems in a tropical climate. The systems modelled consist of an array of PV modules, a lead-acid battery, and a number of direct current appliances. This paper proposes the combination of lead acid battery system with a typical stand alone photovoltaic energy system under variable loads. The main activities of this work purpose to establish library graphical models for each individual component of standalone photovoltaic system. Control strategy has been considered to achieve permanent power supply to the load via photovoltaic/battery based on the power available from the sun. The complete model was simulated under two testing including sunny and cloudy conditions. Simulation of the system using Symbols software was performed and the results of simulation show the superior stable control system and high efficiency. These results have been contrasted with real measured data from a measurement campaign plant carried on electrical engineering laboratory of Grenoble using various interconnection schemes are presented.

  7. Structure Optimization of Stand-Alone Renewable Power Systems Based on Multi Object Function

    Directory of Open Access Journals (Sweden)

    Jae-Hoon Cho

    2016-08-01

    Full Text Available This paper presents a methodology for the size optimization of a stand-alone hybrid PV/wind/diesel/battery system while considering the following factors: total annual cost (TAC, loss of power supply probability (LPSP, and the fuel cost of the diesel generator required by the user. A new optimization algorithm and an object function (including a penalty method are also proposed; these assist with designing the best structure for a hybrid system satisfying the constraints. In hybrid energy system sources such as photovoltaic (PV, wind, diesel, and energy storage devices are connected as an electrical load supply. Because the power produced by PV and wind turbine sources is dependent on the variation of the resources (sun and wind and the load demand fluctuates, such a hybrid system must be able to satisfy the load requirements at any time and store the excess energy for use in deficit conditions. Therefore, reliability and cost are the two main criteria when designing a stand-alone hybrid system. Moreover, the operation of a diesel generator is important to achieve greater reliability. In this paper, TAC, LPSP, and the fuel cost of the diesel generator are considered as the objective variables and a hybrid teaching–learning-based optimization algorithm is proposed and used to choose the best structure of a stand-alone hybrid PV/wind/diesel/battery system. Simulation results from MATLAB support the effectiveness of the proposed method and confirm that it is more efficient than conventional methods.

  8. Optimization of stand-alone photovoltaic systems with hydrogen storage for total energy self-sufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lund, P D [Helsinki Univ. of Technology, Espoo (Finland). Dept. of Technical Physics

    1991-01-01

    A new method for optimization of stand-alone photovoltaic-hydrogen energy systems is presented. The methodology gives the optimum values for the solar array and hydrogen storage size for any given system configuration and geographical site. Sensitivity analyses have been performed to study the effect of subsystem efficiencies on the total system performance and sizing, and also to identify possibilities for further improvements. Optimum system configurations have also been derived. The results indicate that a solar-hydrogen energy system is a very promising potential alternative for low power applications requiring a total electricity self-sufficiency. (Author).

  9. Lossy Data Aggregation with Network Coding in Stand-Alone Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Madsen, Tatiana Kozlova

    2011-01-01

    in chemical plants, etc. Given resource constrained operation of a sensor network where the nodes are battery powered and buffer sizes are limited, efficient methods for in-network data storage abd it subsequent fast and reliable transmission to a gateway is desirable. To save scarse resources and to prolong......This work focuses on a special type of wireless sensor networks (WSNs) that we refer to as a stand alone network. These netwoks operate in harsh and extreme environments where data collection is done only occasionally. Typical examples include habitat monitoring systems, monitoring systems...

  10. Boost converter with combined control loop for a stand-alone photovoltaic battery charge system

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Thomsen, Ole Cornelius

    2013-01-01

    frequency avoids perturbations in the load being propagated to the photovoltaic panel and thus deviating the operating point. Linearization of the photovoltaic panel and converter state-space modeling is performed. In order to achieve stable operation under all operating conditions, the photovoltaic panel......The converter control scheme plays an important role in the performance of maximum power point tracking (MPPT) algorithms. In this paper, an input voltage control with double loop for a stand-alone photovoltaic system is designed and tested. The inner current control loop with high crossover...

  11. System design optimization for stand-alone photovoltaic systems sizing by using superstructure model

    International Nuclear Information System (INIS)

    Azau, M A M; Jaafar, S; Samsudin, K

    2013-01-01

    Although the photovoltaic (PV) systems have been increasingly installed as an alternative and renewable green power generation, the initial set up cost, maintenance cost and equipment mismatch are some of the key issues that slows down the installation in small household. This paper presents the design optimization of stand-alone photovoltaic systems using superstructure model where all possible types of technology of the equipment are captured and life cycle cost analysis is formulated as a mixed integer programming (MIP). A model for investment planning of power generation and long-term decision model are developed in order to help the system engineer to build a cost effective system.

  12. Design, building and testing of a stand alone fuel cell hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Segura, F.; Duran, E.; Andujar, J.M. [Department of Electronic, Computer Science and Automatic Engineering, University of Huelva (Spain)

    2009-08-01

    This paper designs, sizes, builds and tests a stand alone fuel cell hybrid system made up of a fuel cell stack and a battery bank. This system has been sized to supply a typical telecommunication load profile, but moreover, the system can supply other profiles. For this purpose, a modular low cost electronic load bank has been designed and built. This load bank allows the power demand to be chosen by selecting different solid state relays. Moreover, a virtual instrument based on NI Labview {sup registered} has been designed to select the load power demand from the computer. (author)

  13. Design and Operation Studies of A Stand-Alone PV Generation System

    DEFF Research Database (Denmark)

    Hu, Yanting; Chen, Zhe; Zhang, Donglai

    2013-01-01

    This paper discusses the modeling, design and operation of a PV powered stand-alone system, which includes a PV array, a battery bank, power electronic converters and the associated control system. The design considerations are analyzed and a design platform is presented. Furthermore the operation...... modes of the system are described. A power electronic system with the associated control scheme has been proposed and simulation models have been developed. Simulation studies have been conducted on an example system; the results have demonstrated the effectiveness of the presented methods....

  14. State Feedback Decoupling with In-Loop Lead Compensator in Stand-Alone VSIs

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; de Sousa Ribeiro, Luiz Antonio

    2016-01-01

    The performance of current and voltage regulators during transients and steady-state is of primary concern for power converters intended for stand-alone applications. Dynamics performance and command tracking capability are enhanced by actively decoupling the controlled states variables. To further...... widen the current loop bandwidth while still preserving a well-damped system a lead compensator structure on the forward loop is proposed. A 3 kHz bandwidth with 0.707 damping factor is achieved for the inner current controller. Accordingly, also the voltage regulator bandwidth can be widen, thus...

  15. Information systems for the materials management department: stand-alone and enterprise resource planning systems.

    Science.gov (United States)

    2005-03-01

    Materials management information systems (MMISs) incorporate information tools that hospitals can use to automate certain business processes, increase staff compliance with these processes, and identify opportunities for cost savings. Recently, there has been a push by hospital administration to purchase enterprise resource planning (ERP) systems, information systems that promise to integrate many more facets of healthcare business. We offer this article to help materials managers, administrators, and others involved with information system selection understand the changes that have taken place in materials management information systems, decide whether they need a new system and, if so, whether a stand-alone MMIS or an ERP system will be the best choice.

  16. Simulation of stand alone PV systems; Dokuritsugata taiyoko hatsuden system no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, I.; Sakuta, K. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T. [Japan Quality Assurance Organization, Tokyo (Japan); Kurokawa, K. [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1997-11-25

    Studies are performed to develop a simulation program for a stand-alone photovoltaic power generation system equipped with a lead acid battery. In this stand-alone photovoltaic power generation system, the load is connected in shunt with the solar cell array output through the intermediary of a lead acid battery and inverter. The program is a model in which the solar cell model is built taking parallel resistance into account, and the temperature-dependence of the constants is described using approximations experimentally obtained by Solar Techno Center of JQA (Japan Quality Assurance Organization), Hamamatsu. Insolation data for the model is described using METPV compiled by Japan Weather Association, and load data is described using data actually measured at Shizuoka. This program is compared with the data of operation at Hamamatsu, and the result is almost satisfactory. Simulations are conducted at five typical locations in Japan using this program, and it is found that the array load matching correction factor is dependent on seasonal changes rather than locality, that the battery contribution rate does not change much throughout the year, and that it is not dependent on locality. 5 refs., 7 figs., 3 tabs.

  17. Modified Chaos Particle Swarm Optimization-Based Optimized Operation Model for Stand-Alone CCHP Microgrid

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2017-07-01

    Full Text Available The optimized dispatch of different distributed generations (DGs in stand-alone microgrid (MG is of great significance to the operation’s reliability and economy, especially for energy crisis and environmental pollution. Based on controllable load (CL and combined cooling-heating-power (CCHP model of micro-gas turbine (MT, a multi-objective optimization model with relevant constraints to optimize the generation cost, load cut compensation and environmental benefit is proposed in this paper. The MG studied in this paper consists of photovoltaic (PV, wind turbine (WT, fuel cell (FC, diesel engine (DE, MT and energy storage (ES. Four typical scenarios were designed according to different day types (work day or weekend and weather conditions (sunny or rainy in view of the uncertainty of renewable energy in variable situations and load fluctuation. A modified dispatch strategy for CCHP is presented to further improve the operation economy without reducing the consumers’ comfort feeling. Chaotic optimization and elite retention strategy are introduced into basic particle swarm optimization (PSO to propose modified chaos particle swarm optimization (MCPSO whose search capability and convergence speed are improved greatly. Simulation results validate the correctness of the proposed model and the effectiveness of MCPSO algorithm in the optimized operation application of stand-alone MG.

  18. Design of a Stand-Alone Photovoltaic Model for Home Lightings and Clean Environment

    Energy Technology Data Exchange (ETDEWEB)

    Ani, Vincent Anayochukwu, E-mail: vincent_ani@yahoo.com [Department of Electronic Engineering, University of Nigeria, Nsukka (Nigeria)

    2016-01-11

    This paper gives a well-documented health risk of fuel-based lighting (kerosene lamps and fuel-powered generators) and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs) using two different battery types (Rolls Surrette 6CS25PS and Hoppecke 10 OpzS 1000) on; (i) judicious power consumption, (ii) normal power consumption, and (iii) excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedures were used to demonstrate the best solution (reliability at the lowest lifecycle cost). Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with EEL options (judicious power consumption, normal power consumption, and excess power consumption).

  19. Fuzzy logic control of stand-alone photovoltaic system with battery storage

    Science.gov (United States)

    Lalouni, S.; Rekioua, D.; Rekioua, T.; Matagne, E.

    Photovoltaic energy has nowadays an increased importance in electrical power applications, since it is considered as an essentially inexhaustible and broadly available energy resource. However, the output power provided via the photovoltaic conversion process depends on solar irradiation and temperature. Therefore, to maximize the efficiency of the photovoltaic energy system, it is necessary to track the maximum power point of the PV array. The present paper proposes a maximum power point tracker (MPPT) method, based on fuzzy logic controller (FLC), applied to a stand-alone photovoltaic system. It uses a sampling measure of the PV array power and voltage then determines an optimal increment required to have the optimal operating voltage which permits maximum power tracking. This method carries high accuracy around the optimum point when compared to the conventional one. The stand-alone photovoltaic system used in this paper includes two bi-directional DC/DC converters and a lead-acid battery bank to overcome the scare periods. One converter works as an MPP tracker, while the other regulates the batteries state of charge and compensates the power deficit to provide a continuous delivery of energy to the load. The Obtained simulation results show the effectiveness of the proposed fuzzy logic controller.

  20. A sizing method for stand-alone PV installations with variable demand

    Energy Technology Data Exchange (ETDEWEB)

    Posadillo, R. [Grupo de Investigacion en Energias y Recursos Renovables, Dpto. de Fisica Aplicada, E.P.S., Universidad de Cordoba, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Lopez Luque, R. [Grupo de Investigacion de Fisica Para las Energias y Recursos Renovables, Dpto. de Fisica Aplicada, Edificio C2 Campus de Rabanales, 14071 Cordoba (Spain)

    2008-05-15

    The practical applicability of the considerations made in a previous paper to characterize energy balances in stand-alone photovoltaic systems (SAPV) is presented. Given that energy balances were characterized based on monthly estimations, the method is appropriate for sizing installations with variable monthly demands and variable monthly panel tilt (for seasonal estimations). The method presented is original in that it is the only method proposed for this type of demand. The method is based on the rational utilization of daily solar radiation distribution functions. When exact mathematical expressions are not available, approximate empirical expressions can be used. The more precise the statistical characterization of the solar radiation on the receiver module, the more precise the sizing method given that the characterization will solely depend on the distribution function of the daily global irradiation on the tilted surface H{sub g{beta}}{sub i}. This method, like previous ones, uses the concept of loss of load probability (LLP) as a parameter to characterize system design and includes information on the standard deviation of this parameter ({sigma}{sub LLP}) as well as two new parameters: annual number of system failures (f) and the standard deviation of annual number of system failures ({sigma}{sub f}). This paper therefore provides an analytical method for evaluating and sizing stand-alone PV systems with variable monthly demand and panel inclination. The sizing method has also been applied in a practical manner. (author)

  1. Design of a Stand-Alone Photovoltaic (PV Models for Home Lightings and Clean Environment

    Directory of Open Access Journals (Sweden)

    Vincent Anayochukwu Ani

    2016-01-01

    Full Text Available This paper gives a well-documented health risks of fuel-based lighting (kerosene lamps and fuel-powered generators and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs using two different battery types (Rolls Surrette 6CS25PS and hoppecke 10 OpzS 1000 on; i judicious power consumption, ii normal power consumption, iii excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedure were used to demonstrate the best solution (reliability at the lowest lifecycle cost. Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with energy efficient lighting options (judicious power consumption, normal power consumption, and excess power consumption.

  2. International market assessment of stand-alone photovoltaic power systems for cottage industry applications

    Science.gov (United States)

    Philippi, T. M.

    1981-01-01

    The final result of an international assessment of the market for stand-alone photovoltaic systems in cottage industry applications is reported. Nonindustrialized countries without centrally planned economies were considered. Cottage industries were defined as small rural manufacturers, employing less than 50 people, producing consumer and simple products. The data to support this analysis were obtained from secondary and expert sources in the U.S. and in-country field investigations of the Philippines and Mexico. The near-term market for photovoltaics for rural cottage industry applications appears to be limited to demonstration projects and pilot programs, based on an in-depth study of the nature of cottage industry, its role in the rural economy, the electric energy requirements of cottage industry, and a financial analysis of stand-alone photovoltaic systems as compared to their most viable competitor, diesel driven generators. Photovoltaics are shown to be a better long-term option only for very low power requirements. Some of these uses would include clay mixers, grinders, centrifuges, lathes, power saws and lighting of a workshop.

  3. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  4. International market assessment of stand-alone photovoltaic power systems for cottage industry applications

    Science.gov (United States)

    Philippi, T. M.

    1981-11-01

    The final result of an international assessment of the market for stand-alone photovoltaic systems in cottage industry applications is reported. Nonindustrialized countries without centrally planned economies were considered. Cottage industries were defined as small rural manufacturers, employing less than 50 people, producing consumer and simple products. The data to support this analysis were obtained from secondary and expert sources in the U.S. and in-country field investigations of the Philippines and Mexico. The near-term market for photovoltaics for rural cottage industry applications appears to be limited to demonstration projects and pilot programs, based on an in-depth study of the nature of cottage industry, its role in the rural economy, the electric energy requirements of cottage industry, and a financial analysis of stand-alone photovoltaic systems as compared to their most viable competitor, diesel driven generators. Photovoltaics are shown to be a better long-term option only for very low power requirements. Some of these uses would include clay mixers, grinders, centrifuges, lathes, power saws and lighting of a workshop.

  5. Feasibility and Optimal Design of a Stand-Alone Photovoltaic Energy System for the Orphanage

    Directory of Open Access Journals (Sweden)

    Vincent Anayochukwu Ani

    2014-01-01

    Full Text Available Access to electricity can have a positive psychological impact through a lessening of the sense of exclusion, and vulnerability often felt by the orphanages. This paper presented the simulation and optimization study of a stand-alone photovoltaic power system that produced the desired power needs of an orphanage. Solar resources for the design of the system were obtained from the National Aeronautics and Space Administration (NASA Surface Meteorology and Solar Energy website at a location of 6°51′N latitude and 7°35′E longitude, with annual average solar radiation of 4.92 kWh/m2/d. This study is based on modeling, simulation, and optimization of energy system in the orphanage. The patterns of load consumption within the orphanage were studied and suitably modeled for optimization. Hybrid Optimization Model for Electric Renewables (HOMER software was used to analyze and design the proposed stand-alone photovoltaic power system model. The model was designed to provide an optimal system configuration based on an hour-by-hour data for energy availability and demands. A detailed design, description, and expected performance of the system were presented in this paper.

  6. Design of a Stand-Alone Photovoltaic Model for Home Lightings and Clean Environment

    International Nuclear Information System (INIS)

    Ani, Vincent Anayochukwu

    2016-01-01

    This paper gives a well-documented health risk of fuel-based lighting (kerosene lamps and fuel-powered generators) and proposed a design of a stand-alone solar PV system for sustainable home lightings in rural Nigerian area. The design was done in three different patterns of electricity consumptions with energy efficient lightings (EELs) using two different battery types (Rolls Surrette 6CS25PS and Hoppecke 10 OpzS 1000) on; (i) judicious power consumption, (ii) normal power consumption, and (iii) excess power consumption; and compared them with the incandescent light bulb consumption. The stand-alone photovoltaic energy systems were designed to match the rural Nigerian sunlight and weather conditions to meet the required lightings of the household. The objective function and constraints for the design models were formulated and optimization procedures were used to demonstrate the best solution (reliability at the lowest lifecycle cost). Initial capital costs as well as annualized costs over 5, 10, 15, 20, and 25 years were quantified and documented. The design identified the most cost-effective and reliable solar and battery array among the patterns of electricity consumption with EEL options (judicious power consumption, normal power consumption, and excess power consumption).

  7. Input of biomass in stand-alone small-scale installations for power generation. Calculation of the financial gap

    International Nuclear Information System (INIS)

    Van Tilburg, X.; De Vries, H.J.; Pfeiffer, A.E.; Beekes, M.; Cleijne, J.W.

    2005-09-01

    A number of new initiatives in which bio-oil is used in stand-alone plants for power generation has been reviewed. The question to be answered is whether the reference case for stand alone biomass projects based on burning of wood chips can still be considered representative for the costs and benefits in this category. ECN, in cooperation with KEMA, have determined the financial gap between the costs and benefits of projects in which bio-oil is used in stand alone plants for power generation. The ranges and reference case for bio-oil in stand alone applications show that these projects have a substantially lower financial gap than the current reference case based on wood chips [nl

  8. Charactrization of a Li-ion battery based stand-alone a-Si photovoltaic system

    International Nuclear Information System (INIS)

    Hamid Vishkasougheh, Mehdi; Tunaboylu, Bahadir

    2014-01-01

    Highlights: • An Li-ion battery based stand-alone a-Si PV was designed. The system composed of three a-Si panels with an efficiency of 7% and 40 cells of LFP batteries. • Effects of solar radiation and environmental temperature for three cities, Istanbul, Ankara, and Adana, have been investigated on a-Si panels. • Using transition formulas BSPV outputs are predictable for any location out of standard test condition. - Abstract: The number of photovoltaic (PV) system installations is increasing rapidly. As more people learn about this versatile and often cost-effective power option, this trend will accelerate. This document presents a recommended design for a battery based stand-alone photovoltaic system (BSPV). BSPV system has the ability to be applied in different areas, including warning signals, lighting, refrigeration, communication, residential water pumping, remote sensing, and cathodic protection. The presented calculation method gives a proper idea for a system sizing technique. Based on application load, different scenarios are possible for designing a BSPV system. In this study, a battery based stand-alone system was designed. The electricity generation part is three a-Si panels, which are connected in parallel, and for the storage part LFP (lithium iron phosphate) battery was used. The high power LFP battery packs are 40 cells each 8S5P (configured 8 series 5 parallel). Each individual pack weighs 0.5 kg and is 25.6 V. In order to evaluate the efficiency of a-Si panels with respect to the temperature and the solar irradiation, cities of Istanbul, Ankara and Adana in Turkey were selected. Temperature and solar irradiation were gathered from reliable sources and by using translation equations, current and voltage output of panels were calculated. As a result of these calculations, current and energy outputs were computed by considering an average efficient solar irradiation time value per day in Turkey. The calculated power values were inserted to a

  9. Charactrization of a Li-ion battery based stand-alone a-Si photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Hamid Vishkasougheh, Mehdi, E-mail: mehdi.hamid2@gmail.com [Istanbul Sehir University, Kubakisi Caddesi, No: 27, Altunizade, Uskudar, Istanbul 34662 (Turkey); Tunaboylu, Bahadir [Istanbul Sehir University, Kubakisi Caddesi, No: 27, Altunizade, Uskudar, Istanbul 34662 (Turkey); Marmara Research Center, Materials Institute, PO Box 21, Gebze, Kocaeli 41470 (Turkey)

    2014-11-01

    Highlights: • An Li-ion battery based stand-alone a-Si PV was designed. The system composed of three a-Si panels with an efficiency of 7% and 40 cells of LFP batteries. • Effects of solar radiation and environmental temperature for three cities, Istanbul, Ankara, and Adana, have been investigated on a-Si panels. • Using transition formulas BSPV outputs are predictable for any location out of standard test condition. - Abstract: The number of photovoltaic (PV) system installations is increasing rapidly. As more people learn about this versatile and often cost-effective power option, this trend will accelerate. This document presents a recommended design for a battery based stand-alone photovoltaic system (BSPV). BSPV system has the ability to be applied in different areas, including warning signals, lighting, refrigeration, communication, residential water pumping, remote sensing, and cathodic protection. The presented calculation method gives a proper idea for a system sizing technique. Based on application load, different scenarios are possible for designing a BSPV system. In this study, a battery based stand-alone system was designed. The electricity generation part is three a-Si panels, which are connected in parallel, and for the storage part LFP (lithium iron phosphate) battery was used. The high power LFP battery packs are 40 cells each 8S5P (configured 8 series 5 parallel). Each individual pack weighs 0.5 kg and is 25.6 V. In order to evaluate the efficiency of a-Si panels with respect to the temperature and the solar irradiation, cities of Istanbul, Ankara and Adana in Turkey were selected. Temperature and solar irradiation were gathered from reliable sources and by using translation equations, current and voltage output of panels were calculated. As a result of these calculations, current and energy outputs were computed by considering an average efficient solar irradiation time value per day in Turkey. The calculated power values were inserted to a

  10. Loss-of-load probabilities for stand-alone photovoltaic systems

    International Nuclear Information System (INIS)

    Klein, S.A.; Beckman, W.A.

    1989-01-01

    A general method is presented for estimating the loss-of-load probability of stand-alone photovoltaic systems. The method was developed by correlating simulation results. The simulations were driven with synthetic radiation sequences having the same statistical significance as available historical data. The methods assumes a constant nighttime load and accounts for the distribution and persistence in daily solar radiation data. It is shown that the 10 year average performance of systems having loss-of-load probabilities less than about 0.01 can vary greatly from one ten year period to the next and thereby cannot be considered realistic performance estimates of a system during its lifetime. (author). 26 refs, 15 figs, 4 tabs

  11. Size optimization of stand-alone photovoltaic (PV) room air conditioners

    International Nuclear Information System (INIS)

    Chen, Chien-Wei; Zahedi, A.

    2006-01-01

    Sizing of a stand-alone PV system determines the main cost of the system. PV electricity cost is determined by the amount of solar energy received, hence the actual climate and weather conditions such as solar irradiance and ambient temperature affect the size required and cost of the system. Air conditioning demand also depends on the weather conditions. Therefore, sizing a PV powered air conditioner must consider the characteristics of local climate and temperature. In this paper, sizing procedures and special considerations for air conditioning under Melbourne's climatic conditions is presented. The reliability of various PV-battery size combinations is simulated by MATLAB. As a result, excellent system performance can be predicated.(Author)

  12. An Analysis of Stand-alone GPS Quality and Simulated GNSS Quality for Road Pricing

    DEFF Research Database (Denmark)

    Zabic, Martina; Nielsen, Otto Anker

    2006-01-01

    Use of GPS for road pricing has often been suggested as the way of creating more efficient charging strategies than existing systems based on cordon lines or time use. In Denmark, Copenhagen participated with the AKTA project in the PRoGRESS programme, sponsored by the EU. The major part...... of the AKTA project was to equip 500 cars with GPS receivers. The paper presents the methods and results from a study of GPS quality in relation to road pricing in a dense urban area. The collected data from 500 cars over a two-year period in the Copenhagen region was analyzed in order to determine whether...... the stand alone GPS quality and reliability is adequate for implementation of an operational road pricing system in Copenhagen. The results from the analysis show that the satellite availability in Copenhagen is not sufficient to form the basis for a reliable operational road pricing system. The narrow...

  13. Integrated Three-Port DC-DC Converter for Photovoltaic (PV) Battery Stand-alone Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    of solar energy. Moreover, a novel transformer configuration enables variable turns ratio controlled by the phase between the two current excitations subjected to the primary windings, allowing a wider input/output range. 1 kW experimental prototype has been built to demonstrate a wellmanaged power flow......Several power sources such as PV solar arrays and battery are often used to manage the power flow for a photovoltaic (PV) based stand-alone power system due to the fluctuation nature of solar energy resource, and deliver a continuous power to the users in an appropriate form. Traditionally, three...... different single-input single-output (SISO) dc/dc converters would have been used. To reduce the cost and improve the power density of the system, an integrated three-port isolated dc/dc converter is proposed in this paper. It can realize all functions of the energy delivery due to the fluctuation nature...

  14. Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line

    Science.gov (United States)

    Malla, S. G.; Bhende, C. N.

    2014-10-01

    The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.

  15. Solar pv fed stand-alone excitation system of a synchronous machine for reactive power generation

    Science.gov (United States)

    Sudhakar, N.; Jain, Siddhartha; Jyotheeswara Reddy, K.

    2017-11-01

    This paper presents a model of a stand-alone solar energy conversion system based on synchronous machine working as a synchronous condenser in overexcited state. The proposed model consists of a Synchronous Condenser, a DC/DC boost converter whose output is fed to the field of the SC. The boost converter is supplied by the modelled solar panel and a day time variable irradiance is fed to the panel during the simulation time. The model also has one alternate source of rechargeable batteries for the time when irradiance falls below a threshold value. Also the excess power produced when there is ample irradiance is divided in two parts and one is fed to the boost converter while other is utilized to recharge the batteries. A simulation is done in MATLAB-SIMULINK and the obtained results show the utility of such modelling for supplying reactive power is feasible.

  16. Use of small stand-alone Internet nodes as a distributed control system

    Science.gov (United States)

    Goodwin, Robert W.; Kucera, Michael J.; Shea, Michael F.

    1994-12-01

    For several years, the standard model for accelerator control systems has been workstation consoles connected to VME local stations by a Local Area Network with analog and digital data being accessed via a field bus to custom I/O interface electronics. Commercially available hardware has now made it possible to implement a small stand-alone data acquisition station that combines the LAN connection, the computer, and the analog and digital I/O interface on a single board. This eliminates the complexity of a field bus and the associated proprietary I/O hardware. A minimum control system is one data acquisition station and a Macintosh or workstation console, both connected to the network; larger systems have more consoles and nodes. An implementation of this architecture is described along with performance and operational experience.

  17. Stand-Alone Photovoltaic System Operation with Energy Management and Fault Tolerant

    International Nuclear Information System (INIS)

    Jmashidpour, Ehsan; Poure, Philippe; Gholipour, E.; Saadate, Shahrokh

    2017-01-01

    This paper presents a stand-alone photovoltaic (PV) system with a fault tolerant operation capability. An energy management method is provided to keep the balance between produced and consumed energy instantaneously. As the storage element, an Ultra-Capacitor (UC) pack is used for facing high frequency variation of the load/source, and batteries are in charge of slow load /source variations. A Maximum Power Point Tracking (MPPT) algorithm is applied to control the boost converter of the PV source to achieve the maximum power. In order to improve the micro-grid service continuity and reliability, a fast fault diagnosis method based on the converter current shape for PV source is applied. Finally, the validity of the proposed energy management and the fault diagnosis method is confirmed by the simulation and experimental results. (author)

  18. JAERI Fuel Cleanup System (J-FCU) stand-alone tritium test at the TSTA

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Hayashi, Takumi; Inoue, Masahiko

    1993-03-01

    JAERI designed, fabricated, and installed the JAERI Fuel Cleanup System (J-FCU) as a subsystem of simulated fusion fuel loop at the TSTA. The main function of the J-FCU is to purify and to recover hydrogen isotopes from simulated plasma exhaust while exhausting tritium free impurities. After a lot of deuterium tests, a first tritium test of the J-FCU was performed with one gram of tritium at the TSTA on June 1991. Main purpose of this test was to evaluate the total integrity and function of the J-FCU system with a DT mixture. Through this test, the J-FCU was operated well and its function with tritium was demonstrated. This report describes the detail test results of the J-FCU first tritium test and discuss its functions by stand-alone mode. Residual tritium inventory of the J-FCU system was also discussed. (author)

  19. System Simulation by Recursive Feedback: Coupling a Set of Stand-Alone Subsystem Simulations

    Science.gov (United States)

    Nixon, D. D.

    2001-01-01

    Conventional construction of digital dynamic system simulations often involves collecting differential equations that model each subsystem, arran g them to a standard form, and obtaining their numerical gin solution as a single coupled, total-system simultaneous set. Simulation by numerical coupling of independent stand-alone subsimulations is a fundamentally different approach that is attractive because, among other things, the architecture naturally facilitates high fidelity, broad scope, and discipline independence. Recursive feedback is defined and discussed as a candidate approach to multidiscipline dynamic system simulation by numerical coupling of self-contained, single-discipline subsystem simulations. A satellite motion example containing three subsystems (orbit dynamics, attitude dynamics, and aerodynamics) has been defined and constructed using this approach. Conventional solution methods are used in the subsystem simulations. Distributed and centralized implementations of coupling have been considered. Numerical results are evaluated by direct comparison with a standard total-system, simultaneous-solution approach.

  20. Imagery rescripting as a stand-alone treatment for patients with social phobia: a case series.

    Science.gov (United States)

    Frets, Petra G; Kevenaar, Ciska; van der Heiden, Colin

    2014-03-01

    The majority of patients with social phobia reports experiencing negative images, usually linked to memories of earlier aversive social experiences. Several studies have indicated that such negative self-imagery appears to have a causal role in maintaining social phobia, which suggests that interventions aimed at dealing with these images could be beneficial in the treatment of social phobia. One potentially powerful approach is imagery rescripting (IR), a clinical intervention that focuses on changing the meaning and impact of unpleasant memories. In the treatment of social phobia IR was only used as part of a broader cognitive-behavioral treatment package. However, we propose that IR alone might also be an effective treatment for this anxiety disorder. The present study reports an initial evaluation of the application of IR as a stand-alone treatment for six adult outpatients presenting with social phobia. A single case series using an A-B replication across patients design was employed. Following a no-treatment baseline period, IR was delivered weekly and patients were followed up for 3 and 6 months. For all patients, substantial reductions were obtained on all outcome measures at post-treatment, and gains were largely maintained at 6-months follow-up. The generalizability of the effects of IR for social phobia is limited by the small number of patients treated by only one therapist. The results of this preliminary case series suggest that IR as a stand alone treatment is an apparently effective intervention in the treatment of patients with social phobia, and indicate that controlled evaluation of its efficacy might be worthwhile. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Optimal expansion planning of stand-alone systems with stochastic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hoese, Alejandro [Instituto de Energia Electrica (IEE), Universidad Nacional de San Juan, (Argentina)

    1997-12-31

    Stand-alone systems in the range of 1 kW - 10 MW are taking relevance in the new (global) liberal concept of energy market. State and private investors are becoming increasingly attention on the use of renewable for these systems, but it must be shown that these non-conventional solutions are competitive with the established conventional ones. The high investment costs and the technical and economic uncertainties coupled with the use of time-dependent energy sources are the mainly inhibiting factors for the decision agents to choose these systems instead of conventional ones. In the paper a new model for optimal expansion planning of hybrid stand-alone generating systems under consideration of uncertainties is presented. This model is at present in {sup d}evelopment state{sup .} Results already obtained in the first steps of this research are promising and some of them are here presented. [Espanol] Los sistemas autocontenidos en el rango de 1 Kw a 10 MW estan tomando importancia en el nuevo (global) concepto liberal del mercado de la energia. Inversionistas privados y del Estado estan poniendo mayor atencion en el uso de energias renovables para estos sistemas, pero debe mostrarse que estas soluciones no-convencionales son competitivas con las convencionales establecidas. Los altos costos de inversion y las incertidumbres tecnicas y economicas aunadamente con el uso de fuentes de energia dependientes del tiempo son los principales factores inhibidores de los factores de decision para escoger estos sistemas en lugar de los convencionales. En este articulo se presenta un nuevo modelo de planeacion de expansion optima de sistemas hibridos autocontenidos de generacion electrica bajo la consideracion de incertidumbres. Este modelo esta actualmente en {sup e}stado de desarrollo{sup .} Los resultados ya obtenidos en las primeras etapas de esta investigacion son prometedores y se presentan algunos de ellos.

  2. Diagnostic value of the stand-alone synthetic image in digital breast tomosynthesis examinations.

    Science.gov (United States)

    Garayoa, Julia; Chevalier, Margarita; Castillo, Maria; Mahillo-Fernández, Ignacio; Amallal El Ouahabi, Najim; Estrada, Carmen; Tejerina, Alejandro; Benitez, Olivia; Valverde, Julio

    2018-02-01

    To demonstrate the non-inferiority of synthetic image (SI) mammography versus full-field digital mammography (FFDM) in breast tomosynthesis (DBT) examinations. An observational, retrospective, single-centre, multireader blinded study was performed, using 2384 images to directly compare SI and FFDM based on Breast Imaging Reporting and Data System (BIRADS) categorisation and visibility of radiological findings. Readers had no access to digital breast tomosynthesis slices. Multiple reader, multiple case (MRMC) receiver operating characteristic (ROC) methodology was used to compare the diagnostic performance of SI and FFDM images. The kappa statistic was used to estimate the inter-reader and intra-reader reliability. The area under the ROC curves (AUC) reveals the non-inferiority of SI versus FFDM based on BIRADS categorisation [difference between AUC (ΔAUC), -0.014] and lesion visibility (ΔAUC, -0.001) but the differences were not statistically significant (p=0.282 for BIRADS; p=0.961 for lesion visibility). On average, 77.4% of malignant lesions were detected with SI versus 76.5% with FFDM. Sensitivity and specificity of SI are superior to FFDM for malignant lesions scored as BIRADS 5 and breasts categorised as BIRADS 1. SI is not inferior to FFDM when DBT slices are not available during image reading. SI can replace FFDM, reducing the dose by 45%. • Stand-alone SI demonstrated performance not inferior for lesion visibility as compared to FFDM. • Stand-alone SI demonstrated performance not inferior for lesion BIRADS categorisation as compared to FFDM. • Synthetic images provide important dose savings in breast tomosynthesis examinations.

  3. A Meta-Analytic Review of Stand-Alone Interventions to Improve Body Image.

    Directory of Open Access Journals (Sweden)

    Jessica M Alleva

    Full Text Available Numerous stand-alone interventions to improve body image have been developed. The present review used meta-analysis to estimate the effectiveness of such interventions, and to identify the specific change techniques that lead to improvement in body image.The inclusion criteria were that (a the intervention was stand-alone (i.e., solely focused on improving body image, (b a control group was used, (c participants were randomly assigned to conditions, and (d at least one pretest and one posttest measure of body image was taken. Effect sizes were meta-analysed and moderator analyses were conducted. A taxonomy of 48 change techniques used in interventions targeted at body image was developed; all interventions were coded using this taxonomy.The literature search identified 62 tests of interventions (N = 3,846. Interventions produced a small-to-medium improvement in body image (d+ = 0.38, a small-to-medium reduction in beauty ideal internalisation (d+ = -0.37, and a large reduction in social comparison tendencies (d+ = -0.72. However, the effect size for body image was inflated by bias both within and across studies, and was reliable but of small magnitude once corrections for bias were applied. Effect sizes for the other outcomes were no longer reliable once corrections for bias were applied. Several features of the sample, intervention, and methodology moderated intervention effects. Twelve change techniques were associated with improvements in body image, and three techniques were contra-indicated.The findings show that interventions engender only small improvements in body image, and underline the need for large-scale, high-quality trials in this area. The review identifies effective techniques that could be deployed in future interventions.

  4. Optimal expansion planning of stand-alone systems with stochastic simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hoese, Alejandro [Instituto de Energia Electrica (IEE), Universidad Nacional de San Juan, (Argentina)

    1998-12-31

    Stand-alone systems in the range of 1 kW - 10 MW are taking relevance in the new (global) liberal concept of energy market. State and private investors are becoming increasingly attention on the use of renewable for these systems, but it must be shown that these non-conventional solutions are competitive with the established conventional ones. The high investment costs and the technical and economic uncertainties coupled with the use of time-dependent energy sources are the mainly inhibiting factors for the decision agents to choose these systems instead of conventional ones. In the paper a new model for optimal expansion planning of hybrid stand-alone generating systems under consideration of uncertainties is presented. This model is at present in {sup d}evelopment state{sup .} Results already obtained in the first steps of this research are promising and some of them are here presented. [Espanol] Los sistemas autocontenidos en el rango de 1 Kw a 10 MW estan tomando importancia en el nuevo (global) concepto liberal del mercado de la energia. Inversionistas privados y del Estado estan poniendo mayor atencion en el uso de energias renovables para estos sistemas, pero debe mostrarse que estas soluciones no-convencionales son competitivas con las convencionales establecidas. Los altos costos de inversion y las incertidumbres tecnicas y economicas aunadamente con el uso de fuentes de energia dependientes del tiempo son los principales factores inhibidores de los factores de decision para escoger estos sistemas en lugar de los convencionales. En este articulo se presenta un nuevo modelo de planeacion de expansion optima de sistemas hibridos autocontenidos de generacion electrica bajo la consideracion de incertidumbres. Este modelo esta actualmente en {sup e}stado de desarrollo{sup .} Los resultados ya obtenidos en las primeras etapas de esta investigacion son prometedores y se presentan algunos de ellos.

  5. Epicardial, Biatrial Ablation With Integrated Uni-bipolar Radiofrequency Technology in Stand-alone Persistent Atrial Fibrillation.

    Science.gov (United States)

    Rosati, Fabrizio; Muneretto, Claudio; Merati, Elisa; Polvani, Gianluca; Moltrasio, Massimo; Tondo, Claudio; Curnis, Antonio; Cerini, Manuel; Metras, Alexandre; Bisleri, Gianluigi

    Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm. Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation. Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve

  6. Comparison of Turkey’s Geographical Regions in terms of Stand-Alone PV System Design and Cost Parameters

    Directory of Open Access Journals (Sweden)

    Nevzat Onat

    2017-01-01

    Full Text Available Stand-alone photovoltaic (SAPV systems are widely used in rural areas where there is no national grid or as a precaution against power outages. In this study, technical and economic analysis of a SAPV system was carried out using meteorological data for 75 province centers in seven geographical regions of Turkey. Obtained results for each province center were separated by geographical area. The averages of the centers for each region are taken as output. A calculation algorithm based on MsExcel has been established for these operations. The analyses made with the developed algorithm are repeated for five different scenarios that they cover periods of time when a constant strong load is active for all seasons (winter, spring, summer, and autumn and all year round. The developed algorithm calculates the life-cycle cost, the unit energy cost, the electrical capacity utilization rate, the amount of generated/excess energy per month, the initial investment/replacement, and operating and maintenance (O&M costs of each element. As a result, geographical regions of Turkey are compared in terms of these outputs graphically. Further investigations may include the sale of excess energy generated, small-scale PV system cost factors parallel to the grid, and the effects of government incentives.

  7. Key factors for the implementation of successful, stand-alone village electrification schemes in Peru

    Science.gov (United States)

    Sanchez-Campos, Teodoro

    The hypothesis of this work is that there are social, financial, technical, managerial institutional and political key factors that may either support or prevent the success of small stand alone energy systems in rural areas. This research work aims at contributing to the identification of such factors and study their relevance to the performance and sustainability of stand alone energy systems in rural areas; to meet its purpose, a wide range of literature was reviewed including rural electrification programmes and projects, research and development projects on access to electricity in rural areas, impact studies and others, and a field research survey was done the Andes and Upper Jungle regions in Peru. Nineteen possible critical factors were identified, thirteen with relevance at the local context (the community or village), and six with relevance at the national (or wider) context. From literature review it was found that the possible local critical factors were relevant only to four categories of factors instead of the six considered initially (i.e. social, financial, technological and managerial): the other two categories, political and institutional were found to be more relevant to the national context, therefore those were included in the group of possible critical factors of wider context. A series of questionnaires were designed to collect field data information, which was later used to analyse and establish the relation of each identified factor with the success of the systems studied. The survey research was implemented in 14 villages, 7 with small diesel sets and 7 with small hydropower schemes, all spread in the Andes and Upper Jungle of Peru, which were carefully selected to be representative of regions with isolated stand alone systems and with different socioeconomic background. Out of the 13 possible critical factors of local context, it was found that only 3 are really critical, the others are important but not critical; one of them (technical

  8. Multi-objective analytical model for optimal sizing of stand-alone photovoltaic water pumping systems

    International Nuclear Information System (INIS)

    Olcan, Ceyda

    2015-01-01

    Highlights: • An analytical optimal sizing model is proposed for PV water pumping systems. • The objectives are chosen as deficiency of power supply and life-cycle costs. • The crop water requirements are estimated for a citrus tree yard in Antalya. • The optimal tilt angles are calculated for fixed, seasonal and monthly changes. • The sizing results showed the validity of the proposed analytical model. - Abstract: Stand-alone photovoltaic (PV) water pumping systems effectively use solar energy for irrigation purposes in remote areas. However the random variability and unpredictability of solar energy makes difficult the penetration of PV implementations and complicate the system design. An optimal sizing of these systems proves to be essential. This paper recommends a techno-economic optimization model to determine optimally the capacity of the components of PV water pumping system using a water storage tank. The proposed model is developed regarding the reliability and cost indicators, which are the deficiency of power supply probability and life-cycle costs, respectively. The novelty is that the proposed optimization model is analytically defined for two-objectives and it is able to find a compromise solution. The sizing of a stand-alone PV water pumping system comprises a detailed analysis of crop water requirements and optimal tilt angles. Besides the necessity of long solar radiation and temperature time series, the accurate forecasts of water supply needs have to be determined. The calculation of the optimal tilt angle for yearly, seasonally and monthly frequencies results in higher system efficiency. It is, therefore, suggested to change regularly the tilt angle in order to maximize solar energy output. The proposed optimal sizing model incorporates all these improvements and can accomplish a comprehensive optimization of PV water pumping systems. A case study is conducted considering the irrigation of citrus trees yard located in Antalya, Turkey

  9. Five-year durability of stand-alone interspinous process decompression for lumbar spinal stenosis

    Directory of Open Access Journals (Sweden)

    Nunley PD

    2017-09-01

    Full Text Available Pierce D Nunley,1 Vikas V Patel,2 Douglas G Orndorff,3 William F Lavelle,4 Jon E Block,5 Fred H Geisler6 1Spine Institute of Louisiana, Shreveport, LA, 2The Spine Center, University of Colorado Hospital, Denver, CO, 3Spine Colorado, Mercy Regional Hospital, Durango, CO, 4Upstate Bone and Joint Center, East Syracuse, NY, 5Independent Consultant, San Francisco, CA, 6Independent Consultant, Chicago, IL, USA Background: Lumbar spinal stenosis is the most common indication for spine surgery in older adults. Interspinous process decompression (IPD using a stand-alone spacer that functions as an extension blocker offers a minimally invasive treatment option for intermittent neurogenic claudication associated with spinal stenosis.Methods: This study evaluated the 5-year clinical outcomes for IPD (Superion® from a randomized controlled US Food and Drug Administration (FDA noninferiority trial. Outcomes included Zurich Claudication Questionnaire (ZCQ symptom severity (ss, physical function (pf, and patient satisfaction (ps subdomains, leg and back pain visual analog scale (VAS, and Oswestry Disability Index (ODI.Results: At 5 years, 84% of patients (74 of 88 demonstrated clinical success on at least two of three ZCQ domains. Individual ZCQ domain success rates were 75% (66 of 88, 81% (71 of 88, and 90% (79 of 88 for ZCQss, ZCQpf, and ZCQps, respectively. Leg and back pain success rates were 80% (68 of 85 and 65% (55 of 85, respectively, and the success rate for ODI was 65% (57 of 88. Percentage improvements over baseline were 42%, 39%, 75%, 66%, and 58% for ZCQss, ZCQpf, leg and back pain VAS, and ODI, respectively (all P<0.001. Within-group effect sizes were classified as very large for four of five clinical outcomes (ie, >1.0; all P<0.0001. Seventy-five percent of IPD patients were free from reoperation, revision, or supplemental fixation at their index level at 5 years.Conclusion: After 5 years of follow-up, IPD with a stand-alone spacer provides

  10. Efficiency of hydrogen gas production in a stand-alone solar hydrogen system

    International Nuclear Information System (INIS)

    Singh, K.; Tamakloe, R.Y.

    2003-01-01

    Many photovoltaic systems operate in a decentralised electricity producing system, or stand-alone mode and the total energy demand is met by the output of the photovoltaic array. The output of the photovoltaic system fluctuates and is unpredictable for many applications making some forms of energy storage system necessary. The role of storage medium is to store the excess energy produced by the photovoltaic arry, to absorb momentary power peaks and to supply energy during sunless periods. One of the storage modes is the use of electrochemical techniques, with batteries and water electrolysis as the most important examples. The present study includes three main parts: the first one is the hydrogen production form the electrolysis of water depending on the DC output current of the photovoltaic (PV) energy source and the charging of the battery. The second part presents the influence of various parameters on the efficiency of hydrogen gas production. The final part includes simulation studies with focus on solar hydrogen efficiency under the influence of various physical and chemical parameters. For a 50W panel-battery-electrolyser system, the dependence of volume of hydrogen gas on voltage, current and power yielded a maximum efficiency of 13.6% (author)

  11. Control of a Stand-Alone Variable Speed Wind Energy Supply System †

    Directory of Open Access Journals (Sweden)

    Mohamed M. Hamada

    2013-04-01

    Full Text Available This paper presents a simple control strategy for the operation of a variable speed stand-alone wind turbine with a permanent magnet synchronous generator (PMSG. The PMSG is connected to a three phase resistive load through a switch mode rectifier and a voltage source inverter. Control of the generator side converter is used to achieve maximum power extraction from the available wind power. Control of the DC-DC bidirectional buck-boost converter, which is connected between batteries bank and DC-link voltage, is used to maintain the DC-link voltage at a constant value. It is also used to make the batteries bank stores the surplus of wind energy and supplies this energy to the load during a wind power shortage. The load side voltage source inverter uses a relatively complex vector control scheme to control the output load voltage in terms of amplitude and frequency. The control strategy works under wind speed variation as well as with variable load. Extensive simulation results have been performed using MATLAB/SIMULINK.

  12. Optimal sizing method for constituent elements of stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Hirotada; Oi, Yoichi [Hokuriku Electric Power Co., Inc. Toyama (Japan)

    1988-12-25

    The purpose of the report was to calculate the optimal volume of constituent elements of stand-alone photovoltaic power systems, based on the distribution of global radiation on an inclined surface (herein-after called flux of solar radiation), which had been previously measured, and the size of load to be supplied. The least power generation cost was calculated, supposing that setting load was 176kWh/month and the loss of load probability (LOLP) was 1%, by using actual amount of solar radiation in May 1985. The cost was divided into two components: one was proportionate to the size of solar cell, and the other was in proportion to the battery volume. And then, the cost of twenty-year operation(TLC) was calculated. The size of array and the battery volume, which minimize the cost, can be determined when TLC is differentiate. Since auxiliary power source is not attached to this system, it is necessary to restrict the load in order to meet the electric power shortage. In case of the cost at construction in 1984, a standard model indicating the least power generation cost is a photovoltaic system with the array size of A=49.0m{sup 2} and the battery volume of Q=568(Ah). 4 refs., 9 figs., 10 tabs.

  13. Battery Storage Technologies for Electrical Applications: Impact in Stand-Alone Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Daniel Akinyele

    2017-11-01

    Full Text Available Batteries are promising storage technologies for stationary applications because of their maturity, and the ease with which they are designed and installed compared to other technologies. However, they pose threats to the environment and human health. Several studies have discussed the various battery technologies and applications, but evaluating the environmental impact of batteries in electrical systems remains a gap that requires concerted research efforts. This study first presents an overview of batteries and compares their technical properties such as the cycle life, power and energy densities, efficiencies and the costs. It proposes an optimal battery technology sizing and selection strategy, and then assesses the environmental impact of batteries in a typical renewable energy application by using a stand-alone photovoltaic (PV system as a case study. The greenhouse gas (GHG impact of the batteries is evaluated based on the life cycle emission rate parameter. Results reveal that the battery has a significant impact in the energy system, with a GHG impact of about 36–68% in a 1.5 kW PV system for different locations. The paper discusses new batteries, strategies to minimize battery impact and provides insights into the selection of batteries with improved cycling capacity, higher lifespan and lower cost that can achieve lower environmental impacts for future applications.

  14. [Clinical application of stand-alone MC+PEEK cage in the anterior cervical fusion].

    Science.gov (United States)

    Jiang, Bing; Cao, Yan-Qing; Pan, Hong; Zhu, Cheng-Run; Zhang, Xiao-Jun; Tao, Yue-Feng; Liu, Zhen

    2015-04-01

    To explore the effect of clinical application of stand-alone MC+PEEK cage in anterior cervical fusion. From January 2011 to January 2014,50 patients were treated with the MC+PEEK cage filled with autogenous cancellous illic-bone graft after anterior cervical discectomy. There were 22 patients with cervical spondylosis,26 patients with traumatic cervical disc herniation, 2 patients with cervical instability in these patients. There were 32 males and 18 females, aged from 30 to 79 years old with an average of 53.30 years old. There were 32 patients with single segment, 15 patients with double segments and 3 patients with three segments. Cervical AP and lateral and the flexion-extension X-rays were regularly taken in order to assess the cervical physiological curvature, the graft fusion and internal fixation related complications. Nerve function, clinical effect and bone fusion were respectively evaluated according to Japan Orthopedic Association (JOA), Otani grade and Suk method. All patients were followed up from 6 to 36 months with an average of 20 months. No correlated surgical complications were found and all patients obtained bony fusion with an average time of 4.30 months. JOA score had significantly improvement after surgery (P cervical fusion can obtain satisfactory clinical effect with less operation injury and reduce the complications. It is a better fusion method in anterior cervical fusion.

  15. Performance and Simulation of a Stand-alone Parabolic Trough Solar Thermal Power Plant

    Science.gov (United States)

    Mohammad, S. T.; Al-Kayiem, H. H.; Assadi, M. K.; Gilani, S. I. U. H.; Khlief, A. K.

    2018-05-01

    In this paper, a Simulink® Thermolib Model has been established for simulation performance evaluation of Stand-alone Parabolic Trough Solar Thermal Power Plant in Universiti Teknologi PETRONAS, Malaysia. This paper proposes a design of 1.2 kW parabolic trough power plant. The model is capable to predict temperatures at any system outlet in the plant, as well as the power output produced. The conditions that are taken into account as input to the model are: local solar radiation and ambient temperatures, which have been measured during the year. Other parameters that have been input to the model are the collector’s sizes, location in terms of latitude and altitude. Lastly, the results are presented in graphical manner to describe the analysed variations of various outputs of the solar fields obtained, and help to predict the performance of the plant. The developed model allows an initial evaluation of the viability and technical feasibility of any similar solar thermal power plant.

  16. Can aqueous hydrogen peroxide be used as a stand-alone energy source?

    International Nuclear Information System (INIS)

    Disselkamp, Robert S.

    2010-01-01

    A novel electrochemical scheme to convert a stand-alone supply of aqueous hydrogen peroxide into a fuel cell-ready stream of hydrogen gas plus aqueous hydrogen peroxide is described. The electrochemical cell, consisting of a solid base and solid acid electrocatalyst, together with a proton exchange membrane, comprise the system that converts aqueous hydrogen peroxide into separate gas streams of oxygen and hydrogen. Aqueous hydrogen peroxide is contained in the anode compartment only and exists in the region where oxygen gas is formed, whereas the cathode compartment is where hydrogen gas is generated and therefore exists in a reduced state. A near zero theoretical over-potential can be achieved by the choice of basicity and acidity of the electrode materials. The primary cost of the electrochemical cell is electrode construction and the aqueous hydrogen peroxide energy storage compound. Additional research effort is required to experimentally validate the concept and explore the full economic impact should initial studies, based on the design presented here, prove promising. (author)

  17. An intelligent stand-alone ultrasonic device for monitoring local structural damage: implementation and preliminary experiments

    International Nuclear Information System (INIS)

    Pertsch, Alexander; Kim, Jin-Yeon; Wang, Yang; Jacobs, Laurence J

    2011-01-01

    Continuous structural health monitoring has the potential to significantly improve the safety management of aged, in-service civil structures. In particular, monitoring of local damage growth at hot-spot areas can help to prevent disastrous structural failures. Although ultrasonic nondestructive evaluation (NDE) has proved to be effective in monitoring local damage growth, conventional equipment and devices are usually bulky and only suitable for scheduled human inspections. The objective of this research is to harness the latest developments in embedded hardware and wireless communication for developing a stand-alone, compact ultrasonic device. The device is directed at the continuous structural health monitoring of civil structures. Relying on battery power, the device possesses the functionalities of high-speed actuation, sensing, signal processing, and wireless communication. Integrated with contact ultrasonic transducers, the device can generate 1 MHz Rayleigh surface waves in a steel specimen and measure response waves. An envelope detection algorithm based on the Hilbert transform is presented for efficiently determining the peak values of the response signals, from which small surface cracks are successfully identified

  18. Approaches for developing a sizing method for stand-alone PV systems with variable demand

    Energy Technology Data Exchange (ETDEWEB)

    Posadillo, R. [Grupo de Investigacion en Energias y Recursos Renovables, Dpto. de Fisica Aplicada, E.P.S., Universidad de Cordoba, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Lopez Luque, R. [Grupo de Investigacion de Fisica para las Energias y Recursos Renovables, Dpto. de Fisica Aplicada. Edificio C2 Campus de Rabanales, 14071 Cordoba (Spain)

    2008-05-15

    Accurate sizing is one of the most important aspects to take into consideration when designing a stand-alone photovoltaic system (SAPV). Various methods, which differ in terms of their simplicity or reliability, have been developed for this purpose. Analytical methods, which seek functional relationships between variables of interest to the sizing problem, are one of these approaches. A series of rational considerations are presented in this paper with the aim of shedding light upon the basic principles and results of various sizing methods proposed by different authors. These considerations set the basis for a new analytical method that has been designed for systems with variable monthly energy demands. Following previous approaches, the method proposed is based on the concept of loss of load probability (LLP) - a parameter that is used to characterize system design. The method includes information on the standard deviation of loss of load probability ({sigma}{sub LLP}) and on two new parameters: annual number of system failures (f) and standard deviation of annual number of failures ({sigma}{sub f}). The method proves useful for sizing a PV system in a reliable manner and serves to explain the discrepancies found in the research on systems with LLP<10{sup -2}. We demonstrate that reliability depends not only on the sizing variables and on the distribution function of solar radiation, but on the minimum value as well, which in a given location and with a monthly average clearness index, achieves total solar radiation on the receiver surface. (author)

  19. Stand-alone excitation synchronous wind power generators with power flow management strategy

    Directory of Open Access Journals (Sweden)

    Tzuen-Lih Chern

    2014-09-01

    Full Text Available This study presents a stand-alone excitation synchronous wind power generator (SESWPG with power flow management strategy (PFMS. The rotor speed of the excitation synchronous generator tracks the utility grid frequency by using servo motor tracking technologies. The automatic voltage regulator governs the exciting current of generator to achieve the control goals of stable voltage. When wind power is less than the needs of the consumptive loading, the proposed PFMS increases motor torque to provide a positive power output for the loads, while keeping the generator speed constant. Conversely, during the periods of wind power greater than output loads, the redundant power of generator production is charged to the battery pack and the motor speed remains constant with very low power consumption. The advantage of the proposed SESWPG is that the generator can directly output stable alternating current (AC electricity without using additional DC–AC converters. The operation principles with software simulation for the system are described in detail. Experimental results of a laboratory prototype are shown to verify the feasibility of the system.

  20. Analysis and control of induction generator supplying stand-alone AC loads employing a Matrix Converter

    Directory of Open Access Journals (Sweden)

    Sumedha Mahajan

    2017-04-01

    Full Text Available This paper proposes a Capacitor Excited Induction Generator (CEIG-Matrix Converter (MC system for feeding stand-alone AC loads. The variable output voltage magnitude and frequency from CEIG is converted into a constant voltage magnitude and frequency at the load terminals by controlling MC using Space Vector Modulation (SVM technique. This single-stage MC is turned up as a good alternative for the proposed system against commonly used AC/DC/AC two stage power converters. The configuration and implementation of the closed-loop control scheme employing dSPACE 1103 real time controller have been fully described in the paper. The proposed closed-loop controller regulates the AC load voltage irrespective of changes in the prime mover speed and load. A method for predetermining the steady-state performance of the proposed system has been developed and described with relevant analytical expressions. The effectiveness of the proposed system is exemplified through simulation results for various operating conditions. The proposed control technique is further validated using an experimental setup developed in the laboratory.

  1. Solar photovoltaic applications seminar: design, installation and operation of small, stand-alone photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    1980-07-01

    This seminar material was developed primarily to provide solar photovoltaic (PV) applied engineering technology to the Federal community. An introduction to photoconductivity, semiconductors, and solar photovoltaic cells is included along with a demonstration of specific applications and application identification. The seminar details general systems design and incorporates most known information from industry, academia, and Government concerning small solar cell power system design engineering, presented in a practical and applied manner. Solar PV power system applications involve classical direct electrical energy conversion and electric power system analysis and synthesis. Presentations and examples involve a variety of disciplines including structural analysis, electric power and load analysis, reliability, sizing and optimization; and, installation, operation and maintenance. Four specific system designs are demonstrated: water pumping, domestic uses, navigational and aircraft aids, and telecommunications. All of the applications discussed are for small power requirement (under 2 kilowatts), stand-alone systems to be used in remote locations. Also presented are practical lessons gained from currently installed and operating systems, problems at sites and their resolution, a logical progression through each major phase of system acquisition, as well as thorough design reviews for each application.

  2. Use of Super-Capacitor to Enhance Charging Performance of Stand-Alone Solar PV System

    KAUST Repository

    Huang, B. J.

    2011-01-01

    Introduction: The battery charging performance in a stand-alone solar PV system affects the PV system efficiency and the load operating time. The New Energy Center of National Taiwan University has been devoted to the development of a PWM charging technique to continue charging the lead-acid battery after the overcharge point to increase the battery storage capacity by more than 10%. The present study intends to use the super-capacitor to further increase the charge capacity before the overcharge point of the battery. The super-capacitor is connected in parallel to the lead-acid battery. This will reduce the overall charging impedance during the charge and increase the charging current, especially in sunny weather. A system dynamics model of the lead-acid battery and super-capacitor was derived and the control system simulation was carried out to predict the charging performance for various weathers. It shows that the overall battery impedance decreases and charging power increases with increasing solar radiation. An outdoor comparative test for two identical PV systems with and without supercapacitor was carried out. The use of super-capacitor is shown to be able to increase the lead-acid charging capacity by more than 25% at sunny weather and 10% in cloudy weather. © Springer-Verlag Berlin Heidelberg 2011.

  3. On the economics of stand-alone renewable hybrid power plants in remote regions

    International Nuclear Information System (INIS)

    Petrakopoulou, Fontina

    2016-01-01

    Highlights: • Economic evaluation of three renewable hybrid power plants for off-grid operation. • The high electricity cost of remote regions increases the competitiveness of renewable energy. • The proposed plants are economically viable when compared to the existing situation. • The zero direct emissions of the plants constitute an additional advantage of the plants. - Abstract: In recent years ever more examples of regions that have managed to achieve or orientate themselves toward renewable energy sufficiency are emerging. However, actions to create energy autonomy are mainly the result of isolated activities and they are less driven from fully organized movements. In addition, total energy independence without the support of a centralized electrical grid is yet to be achieved. The objectives of this work are to investigate the associated costs of stand-alone renewable hybrid power plants on a Greek island and compare them to the cost of the currently used fossil-fuel-based conventional plant. The plants examined here are designed to fully cover the electricity needs of the island. Islands may face numerous energy problems and rely heavily on foreign and environmentally-harmful fuels. It is shown that the relatively high cost of electricity of such a remote region can increase the competitiveness and promote the wider incorporation of technologies based on renewable energy sources that may, in other cases, seem economically inferior to business-as-usual energy solutions.

  4. MIRNA-DISTILLER: a stand-alone application to compile microRNA data from databases

    Directory of Open Access Journals (Sweden)

    Jessica K. Rieger

    2011-07-01

    Full Text Available MicroRNAs (miRNA are small non-coding RNA molecules of ~22 nucleotides which regulate large numbers of genes by binding to seed sequences at the 3’-UTR of target gene transcripts. The target mRNA is then usually degraded or translation is inhibited, although thus resulting in posttranscriptional down regulation of gene expression at the mRNA and/or protein level. Due to the bioinformatic difficulties in predicting functional miRNA binding sites, several publically available databases have been developed that predict miRNA binding sites based on different algorithms. The parallel use of different databases is currently indispensable, but highly uncomfortable and time consuming, especially when working with numerous genes of interest. We have therefore developed a new stand-alone program, termed MIRNA-DISTILLER, which allows to compile miRNA data for given target genes from public databases. Currently implemented are TargetScan, microCosm, and miRDB, which may be queried independently, pairwise, or together to calculate the respective intersections. Data are stored locally for application of further analysis tools including freely definable biological parameter filters, customized output-lists for both miRNAs and target genes, and various graphical facilities. The software, a data example file and a tutorial are freely available at http://www.ikp-stuttgart.de/content/language1/html/10415.asp

  5. MIRNA-DISTILLER: A Stand-Alone Application to Compile microRNA Data from Databases.

    Science.gov (United States)

    Rieger, Jessica K; Bodan, Denis A; Zanger, Ulrich M

    2011-01-01

    MicroRNAs (miRNA) are small non-coding RNA molecules of ∼22 nucleotides which regulate large numbers of genes by binding to seed sequences at the 3'-untranslated region of target gene transcripts. The target mRNA is then usually degraded or translation is inhibited, although thus resulting in posttranscriptional down regulation of gene expression at the mRNA and/or protein level. Due to the bioinformatic difficulties in predicting functional miRNA binding sites, several publically available databases have been developed that predict miRNA binding sites based on different algorithms. The parallel use of different databases is currently indispensable, but highly uncomfortable and time consuming, especially when working with numerous genes of interest. We have therefore developed a new stand-alone program, termed MIRNA-DISTILLER, which allows to compile miRNA data for given target genes from public databases. Currently implemented are TargetScan, microCosm, and miRDB, which may be queried independently, pairwise, or together to calculate the respective intersections. Data are stored locally for application of further analysis tools including freely definable biological parameter filters, customized output-lists for both miRNAs and target genes, and various graphical facilities. The software, a data example file and a tutorial are freely available at http://www.ikp-stuttgart.de/content/language1/html/10415.asp.

  6. 49 CFR 1109.4 - Mandatory mediation in rate cases to be considered under the stand-alone cost methodology.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Mandatory mediation in rate cases to be considered... § 1109.4 Mandatory mediation in rate cases to be considered under the stand-alone cost methodology. (a) A... methodology must engage in non-binding mediation of its dispute with the railroad upon filing a formal...

  7. An improved synchronous reference frame phase-locked loop for stand-alone variable speed constant frequency power generation systems

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Ke, Longzhang

    2017-01-01

    The phase-locked loop (PLL) based on conventional synchronous reference frame, i.e. dqPLL, is usually employed in grid-connected variable speed constant frequency (VSCF) power generation systems (PGSs). However, the voltage amplitude drop of stand-alone PGSs is often greater than that of the grid...

  8. Analyzing grid extension and stand-alone photovoltaic systems for the cost-effective electrification of Kenya

    NARCIS (Netherlands)

    Zeyringer, Marianne; Pachauri, Shonali; Schmid, Erwin; Schmidt, Johannes; Worrell, Ernst|info:eu-repo/dai/nl/106856715; Morawetz, Ulrich B.

    2015-01-01

    The declaration of 2014-2024 as the Decade of Sustainable Energy for All has catalyzed actions towards achieving universal electricity access. The high costs of building electric infrastructure are a major impediment to improved access, making stand-alone photovoltaic (PV) systems an attractive

  9. Stand-Alone Ethics, Social Responsibility, and Sustainability Course Requirements: A Snapshot from Australia and New Zealand

    Science.gov (United States)

    Rundle-Thiele, Sharyn R.; Wymer, Walter

    2010-01-01

    This article analyzes the extent to which Australian and New Zealand marketing educators use dedicated or stand-alone courses to equip students with alternative views of business. A census of marketing programs in degree-granting universities was conducted. Program brochures were obtained via the Internet and were content analyzed. This study…

  10. The Use of Artificial Neural Networks for Forecasting the Electric Demand of Stand-Alone Consumers

    Science.gov (United States)

    Ivanin, O. A.; Direktor, L. B.

    2018-05-01

    The problem of short-term forecasting of electric power demand of stand-alone consumers (small inhabited localities) situated outside centralized power supply areas is considered. The basic approaches to modeling the electric power demand depending on the forecasting time frame and the problems set, as well as the specific features of such modeling, are described. The advantages and disadvantages of the methods used for the short-term forecast of the electric demand are indicated, and difficulties involved in the solution of the problem are outlined. The basic principles of arranging artificial neural networks are set forth; it is also shown that the proposed method is preferable when the input information necessary for prediction is lacking or incomplete. The selection of the parameters that should be included into the list of the input data for modeling the electric power demand of residential areas using artificial neural networks is validated. The structure of a neural network is proposed for solving the problem of modeling the electric power demand of residential areas. The specific features of generation of the training dataset are outlined. The results of test modeling of daily electric demand curves for some settlements of Kamchatka and Yakutia based on known actual electric demand curves are provided. The reliability of the test modeling has been validated. A high value of the deviation of the modeled curve from the reference curve obtained in one of the four reference calculations is explained. The input data and the predicted power demand curves for the rural settlement of Kuokuiskii Nasleg are provided. The power demand curves were modeled for four characteristic days of the year, and they can be used in the future for designing a power supply system for the settlement. To enhance the accuracy of the method, a series of measures based on specific features of a neural network's functioning are proposed.

  11. The eBioKit, a stand-alone educational platform for bioinformatics.

    Science.gov (United States)

    Hernández-de-Diego, Rafael; de Villiers, Etienne P; Klingström, Tomas; Gourlé, Hadrien; Conesa, Ana; Bongcam-Rudloff, Erik

    2017-09-01

    Bioinformatics skills have become essential for many research areas; however, the availability of qualified researchers is usually lower than the demand and training to increase the number of able bioinformaticians is an important task for the bioinformatics community. When conducting training or hands-on tutorials, the lack of control over the analysis tools and repositories often results in undesirable situations during training, as unavailable online tools or version conflicts may delay, complicate, or even prevent the successful completion of a training event. The eBioKit is a stand-alone educational platform that hosts numerous tools and databases for bioinformatics research and allows training to take place in a controlled environment. A key advantage of the eBioKit over other existing teaching solutions is that all the required software and databases are locally installed on the system, significantly reducing the dependence on the internet. Furthermore, the architecture of the eBioKit has demonstrated itself to be an excellent balance between portability and performance, not only making the eBioKit an exceptional educational tool but also providing small research groups with a platform to incorporate bioinformatics analysis in their research. As a result, the eBioKit has formed an integral part of training and research performed by a wide variety of universities and organizations such as the Pan African Bioinformatics Network (H3ABioNet) as part of the initiative Human Heredity and Health in Africa (H3Africa), the Southern Africa Network for Biosciences (SAnBio) initiative, the Biosciences eastern and central Africa (BecA) hub, and the International Glossina Genome Initiative.

  12. "Candidatus Fokinia solitaria", a Novel "Stand-Alone" Symbiotic Lineage of Midichloriaceae (Rickettsiales.

    Directory of Open Access Journals (Sweden)

    Franziska Szokoli

    Full Text Available Recently, the family Midichloriaceae has been described within the bacterial order Rickettsiales. It includes a variety of bacterial endosymbionts detected in different metazoan host species belonging to Placozoa, Cnidaria, Arthropoda and Vertebrata. Representatives of Midichloriaceae are also considered possible etiological agents of certain animal diseases. Midichloriaceae have been found also in protists like ciliates and amoebae. The present work describes a new bacterial endosymbiont, "Candidatus Fokinia solitaria", retrieved from three different strains of a novel Paramecium species isolated from a wastewater treatment plant in Rio de Janeiro (Brazil. Symbionts were characterized through the full-cycle rRNA approach: SSU rRNA gene sequencing and fluorescence in situ hybridization (FISH with three species-specific oligonucleotide probes. In electron micrographs, the tiny rod-shaped endosymbionts (1.2 x 0.25-0.35 μm in size were not surrounded by a symbiontophorous vacuole and were located in the peripheral host cytoplasm, stratified in the host cortex in between the trichocysts or just below them. Frequently, they occurred inside autolysosomes. Phylogenetic analyses of Midichloriaceae apparently show different evolutionary pathways within the family. Some genera, such as "Ca. Midichloria" and "Ca. Lariskella", have been retrieved frequently and independently in different hosts and environmental surveys. On the contrary, others, such as Lyticum, "Ca. Anadelfobacter", "Ca. Defluviella" and the presently described "Ca. Fokinia solitaria", have been found only occasionally and associated to specific host species. These last are the only representatives in their own branches thus far. Present data do not allow to infer whether these genera, which we named "stand-alone lineages", are an indication of poorly sampled organisms, thus underrepresented in GenBank, or represent fast evolving, highly adapted evolutionary lineages.

  13. Stand-Alone Lateral Interbody Fusion for the Treatment of Low-Grade Degenerative Spondylolisthesis

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2012-01-01

    Full Text Available The purpose of this paper was to investigate the stand-alone lateral interbody fusion as a minimally invasive option for the treatment of low-grade degenerative spondylolisthesis with a minimum 24-month followup. Prospective nonrandomized observational single-center study. 52 consecutive patients (67.6±10 y/o; 73.1% female; 27.4±3.4 BMI with single-level grade I/II single-level degenerative spondylolisthesis without significant spine instability were included. Fusion procedures were performed as retroperitoneal lateral transpsoas interbody fusions without screw supplementation. The procedures were performed in average 73.2 minutes and with less than 50cc blood loss. VAS and Oswestry scores showed lasting improvements in clinical outcomes (60% and 54.5% change, resp.. The vertebral slippage was reduced in 90.4% of cases from mean values of 15.1% preoperatively to 7.4% at 6-week followup (P<0.001 and was maintained through 24 months (7.1%, P<0.001. Segmental lordosis (P<0.001 and disc height (P<0.001 were improved in postop evaluations. Cage subsidence occurred in 9/52 cases (17% and 7/52 cases (13% spine levels needed revision surgery. At the 24-month evaluation, solid fusion was observed in 86.5% of the levels treated. The minimally invasive lateral approach has been shown to be a safe and reproducible technique to treat low-grade degenerative spondylolisthesis.

  14. Study on the optimization of stand-alone type photovoltaic systems. 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Man Geun; Song, Jin Soo; Kim, Boo ho; Park, I June; Jung, Meung Woong; Yoo, Kyun Joung; Kim, Hong Woo [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The objectives of this study are to make a maximization of the operating efficiency of photovoltaic power systems, to improve stand- align PV systems design, technical operation and system analysis, and to promote technical cooperation of mutual interest in the area of IEA/PVPS program. This study aims to investigating the problems of applied photovoltaic power systems currently in operation to improve a system design, seeking remedies of individual PVPS applications to improve the system efficiency and reliability and to raise the system economics, and reporting the international movements of PV system dissemination and technical cooperation for developing countries. For the purpose of this works 1) Investigations of applications of existing photovoltaic power systems: - Photovoltaic electric sources used for expressway lamps - Optimum design of solar light with low pressure sodium lamps under 8 hours lighting a day at night by program-able electronic timer. 2) Comparative analyses of Marado PV system and propose a new reliable PV-diesel hybrid system and high efficiency operations. 3) Overall review of Hahwado 60 KWp PV system extending from 25 KWp and the remote monitoring systems for measurement of its operating results. 4) Introduction of IEA/PVPS international cooperating program, especially in task III for stand- alone PV systems and isolated islands and Exco meeting. As results, investigative findings of PVPS currently in operation and the work for improvement - Propose a prescription of Marado PV systems being blocked up by explosion of electrical demands from residence, parallel operational dual inverter with a big capacity. - There are shortage of solar generated power due to shortage of solar cell capacity that results in an increased operating time of diesel generator. Hence the insolation capacity of solar cell per household is continuously increased from the 0.5 KWp to 2 KWp in Hanwado island electrification.

  15. A Low-Power Wearable Stand-Alone Tongue Drive System for People With Severe Disabilities.

    Science.gov (United States)

    Jafari, Ali; Buswell, Nathanael; Ghovanloo, Maysam; Mohsenin, Tinoosh

    2018-02-01

    This paper presents a low-power stand-alone tongue drive system (sTDS) used for individuals with severe disabilities to potentially control their environment such as computer, smartphone, and wheelchair using their voluntary tongue movements. A low-power local processor is proposed, which can perform signal processing to convert raw magnetic sensor signals to user-defined commands, on the sTDS wearable headset, rather than sending all raw data out to a PC or smartphone. The proposed sTDS significantly reduces the transmitter power consumption and subsequently increases the battery life. Assuming the sTDS user issues one command every 20 ms, the proposed local processor reduces the data volume that needs to be wirelessly transmitted by a factor of 64, from 9.6 to 0.15 kb/s. The proposed processor consists of three main blocks: serial peripheral interface bus for receiving raw data from magnetic sensors, external magnetic interference attenuation to attenuate external magnetic field from the raw magnetic signal, and a machine learning classifier for command detection. A proof-of-concept prototype sTDS has been implemented with a low-power IGLOO-nano field programmable gate array (FPGA), bluetooth low energy, battery and magnetic sensors on a headset, and tested. At clock frequency of 20 MHz, the processor takes 6.6 s and consumes 27 nJ for detecting a command with a detection accuracy of 96.9%. To further reduce power consumption, an application-specified integrated circuit processor for the sTDS is implemented at the postlayout level in 65-nm CMOS technology with 1-V power supply, and it consumes 0.43 mW, which is 10 lower than FPGA power consumption and occupies an area of only 0.016 mm.

  16. Probabilistic modelling and analysis of stand-alone hybrid power systems

    International Nuclear Information System (INIS)

    Lujano-Rojas, Juan M.; Dufo-López, Rodolfo; Bernal-Agustín, José L.

    2013-01-01

    As a part of the Hybrid Intelligent Algorithm, a model based on an ANN (artificial neural network) has been proposed in this paper to represent hybrid system behaviour considering the uncertainty related to wind speed and solar radiation, battery bank lifetime, and fuel prices. The Hybrid Intelligent Algorithm suggests a combination of probabilistic analysis based on a Monte Carlo simulation approach and artificial neural network training embedded in a genetic algorithm optimisation model. The installation of a typical hybrid system was analysed. Probabilistic analysis was used to generate an input–output dataset of 519 samples that was later used to train the ANNs to reduce the computational effort required. The generalisation ability of the ANNs was measured in terms of RMSE (Root Mean Square Error), MBE (Mean Bias Error), MAE (Mean Absolute Error), and R-squared estimators using another data group of 200 samples. The results obtained from the estimation of the expected energy not supplied, the probability of a determined reliability level, and the estimation of expected value of net present cost show that the presented model is able to represent the main characteristics of a typical hybrid power system under uncertain operating conditions. - Highlights: • This paper presents a probabilistic model for stand-alone hybrid power system. • The model considers the main sources of uncertainty related to renewable resources. • The Hybrid Intelligent Algorithm has been applied to represent hybrid system behaviour. • The installation of a typical hybrid system was analysed. • The results obtained from the study case validate the presented model

  17. Feasibility study and energy conversion analysis of stand-alone hybrid renewable energy system

    International Nuclear Information System (INIS)

    Baghdadi, Fazia; Mohammedi, Kamal; Diaf, Said; Behar, Omar

    2015-01-01

    Highlights: • Hybrid stand-alone wind–solar–fossil power system is analyzed. • Measurement data are used to evaluate system performance. • The proposed system can generate about 70% from renewables. • Such a hybrid plant is very promising for remote regions in Algeria. - Abstract: There is a great interest in the development of renewable power technologies in Algeria, and more particularly hybrid concept. The present paper has investigated the performance of hybrid PV–Wind–Diesel–Battery configuration based on hourly measurements of Adrar climate (southern Algeria). Data of global solar radiation, ambient temperature and wind speed for a period of one year have been used. Firstly, the proposed hybrid system has been optimized by means of HOMER software. The optimization process has been carried out taking into account renewable resources potential and energy demand; while maximizing renewable electricity use and fuel saving are the purpose. In the second step, a mathematical model has been developed to ensure efficient energy management on the basis of various operation strategies. The analysis has shown that renewable energy system (PV–Wind) is able to supply about 70% of the demand. Wind power has ranked first with 43% of the annual total electricity production followed by diesel generator (with 31%) while the remaining fraction is being to PV panels. In this context, 69% of the fossil fuel can be saved when using the proposed hybrid configuration instead of the diesel generators that are currently installed in most remote regions in Algeria. Such a concept is very promising to meet the focus of renewable energy program announced in 2011.

  18. Stand alone solution for generation and storage of hydrogen and electric energy

    International Nuclear Information System (INIS)

    Gany, Alon; Elitzur, Shani; Valery

    2015-01-01

    A novel method enabling safe, simple, and controllable production, storage, and use of hydrogen as well as compact electric energy storage and generation via hydrogen- oxygen fuel cells has been developed. The technology indicates, in our opinion, a significant milestone in the search for practical utilization of hydrogen as an alternative energy source. It consists of an original thermal-chemical treatment / activation of aluminum powders to react spontaneously with water to produce hydrogen at regular conditions according to the reaction Al+3H 2 O=Al (OH) 3 +3/2H 2 . Only about 1-2% of lithium, based activator is applied, and any type of water including tap water, sea water and waste water may be used, making the method attractive for variety of applications. 11% of hydrogen compared to the aluminum mass can be obtained, and our experiments reveal 90% reaction yield and more. The technology has a clear advantage over batteries, providing specific electric energy of over 2 kW h/kg Al, 5-10 times greater than that of commonly used lithium-ion batteries. Combined with a fuel cell it may be particularly beneficial for stand-alone electric power generators, where there is no access to the grid. Such applications include emergency generators (e.g., in hospitals), electricity backup systems, and power generation in remote communication posts. Automotive applications may be considered as well. The technology provides green electric energy and quiet operation as well as additional heat energy resulting mainly from the exothermic aluminum-water reaction. (full text)

  19. Post-processing in cardiovascular computed tomography. Performance of a client server solution versus a stand-alone solution

    International Nuclear Information System (INIS)

    Luecke, C.; Foldyna, B.; Andres, C.; Grothoff, M.; Nitzsche, S.; Gutberlet, M.; Lehmkuhl, L.; Boehmer-Lasthaus, S.

    2014-01-01

    Purpose: To compare the performance of server-based (CSS) versus stand-alone post-processing software (ES) for the evaluation of cardiovascular CT examinations (cvCT) and to determine the crucial steps. Data of 40 patients (20 patients for coronary artery evaluation and 20 patients prior to transcatheter aortic valve implantation [TAVI]) were evaluated by 5 radiologists with CSS and ES. Data acquisition was performed using a dual-source 128-row CT unit (SOMATOM Definition Flash, Siemens, Erlangen, Germany) and a 64-row CT unit (Brilliance 64, Philips, Hamburg, Germany). The following workflow was evaluated: Data loading, aorta and coronary segmentation, curved multiplanar reconstruction (cMPR) and 3 D volume rendering technique (3D-VRT), measuring of coronary artery stenosis and planimetry of the aortic annulus. The time requirement and subjective quality for the workflow were evaluated. The coronary arteries as well as the TAVI data could be evaluated significantly faster with CSS (5.5 ± 2.9 min and 8.2 ± 4.0 min, respectively) than with ES (13.9 ± 5.2 min and 15.2 ± 10.9 min, respectively, p = 0.01). Segmentation of the aorta (CSS: 1.9 ± 2.0 min, ES: 3.7 ± 3.3 min), generating cMPR of coronaries (CSS: 0.5 ± 0.2 min, ES: 5.1 ± 2.6 min), aorta and iliac vessels (CSS: 0.5 ± 0.4 min and 0.4 ± 0.4 min, respectively, ES: 1.6 ± 0.7 min and 2.8 ± 3 min, respectively) could be performed significantly faster with CSS than with ES with higher quality of cMPR, measuring of coronary stenosis and 3D-VRT (p < 0.05). Evaluation of cvCT can be accomplished significantly faster and better with CSS than with ES. The segmentation remains the most time-consuming workflow step, so optimization of segmentation algorithms could improve performance even further.

  20. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    Science.gov (United States)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  1. prfectBLAST: a platform-independent portable front end for the command terminal BLAST+ stand-alone suite.

    Science.gov (United States)

    Santiago-Sotelo, Perfecto; Ramirez-Prado, Jorge Humberto

    2012-11-01

    prfectBLAST is a multiplatform graphical user interface (GUI) for the stand-alone BLAST+ suite of applications. It allows researchers to do nucleotide or amino acid sequence similarity searches against public (or user-customized) databases that are locally stored. It does not require any dependencies or installation and can be used from a portable flash drive. prfectBLAST is implemented in Java version 6 (SUN) and runs on all platforms that support Java and for which National Center for Biotechnology Information has made available stand-alone BLAST executables, including MS Windows, Mac OS X, and Linux. It is free and open source software, made available under the GNU General Public License version 3 (GPLv3) and can be downloaded at www.cicy.mx/sitios/jramirez or http://code.google.com/p/prfectblast/.

  2. Modeling, design and analysis of a stand-alone hybrid power generation system using solar/urine

    International Nuclear Information System (INIS)

    Wu, Wei; Zhou, Ya-Yan; Lin, Mu-Hsuan; Hwang, Jenn-Jiang

    2013-01-01

    Highlights: • The stand-alone hybrid power system is presented. • The urine-to-hydrogen processor is proposed. • Scenario analysis of the hybrid power dispatching and the urine/solar demands is investigated. • The design, modeling and optimization of the hybrid power system is addressed by Aspen Plus and Matlab. - Abstract: The urine turned to hydrogen as an energy conversion process is integrated into a stand-alone hybrid (PV/FC/battery) power generation system. The optimization and simulation of a new urine-to-hydrogen processor is evaluated in Aspen Plus environment. In our approach, the PV generator aims to reduce urine consumption and the lithium-ion battery can compensate the power gap due to the fuel processing delay. Based on prescribed patterns of solar irradiation and the daily load demand of a 30-persons classroom, scenario analyses of the hybrid power dispatching and operational feasibility is addressed

  3. Enhancement of a stand-alone photovoltaic system's performance: Reduction of soft and hard shading

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, Lisa A.; El Chaar, Lana [Petroleum Institute, Electrical Engineering Department, P.O. Box 2533, Abu Dhabi (United Arab Emirates)

    2011-04-15

    A stand-alone photovoltaic (PV) system is the most promising solution to supply electric power to meet energy demand in isolated locations. This technology can offer an interesting alternative to other currently existing sources of energy. Due to space constraint in the remote offshore oil and gas industry, a stand-alone system is used for cathodic protection, telemetry and valve control. However in such an environment, dust accumulation and bird droppings have been critical issues to the operation of off-grid solar devices. These factors do not only reduce the available power of the modules but also makes the cost of solar devices ineffective since cleaning, especially on well-head towers, is very expensive due to the location. Hence this paper presents two technical solutions that have shown promising results in reducing the impact of these factors. (author)

  4. A review of three stand-alone topical thrombins for surgical hemostasis.

    Science.gov (United States)

    Cheng, Christine M; Meyer-Massetti, Carla; Kayser, Steven R

    2009-01-01

    Topical thrombins are active hemostatic agents that can be used to minimize blood loss during surgery. Before 2007, the only topical thrombins available were derived from bovine plasma. Antibody formation to bovine thrombin and/or factor V, with subsequent risk of cross-reactivity with human factor V, and hemorrhagic complications associated with human factor-V deficiencies have been described in case reports of surgeries in which bovine thrombins were used. This risk is now included in the boxed warning section of the bovine thrombin prescribing information. In 2007 and 2008, 2 new topical thrombins from nonbovine sources received approval for use from the US Food and Drug Administration. The 3 active topical thrombins that are currently marketed are bovine plasma-derived thrombin, human plasma-derived thrombin, and human recombinant thrombin. The purpose of this review was to evaluate the literature on the efficacy and safety of topical thrombins and discuss the pharmacoeconomic considerations associated with their use. PubMed, EMBASE, and International Pharmaceutical Abstracts were searched for relevant papers published in English through October 10,2008, using the terms thrombin, human recombinant thrombin, bovine thrombin, plasma derived thrombin, and topical thrombin. Manufacturer-provided materials were also reviewed. Abstracts and unpublished data, as well as evaluations of sealants, adhesives, glues, and other hemostats that contain thrombin mixed with fibrinogen and other clotting factors, were excluded. Four randomized, double-blind studies involving the active, stand-alone topical thrombins were found. The bovine thrombin involved in these studies was the predecessor to the currently marketed, highly purified bovine formulation. No studies comparing the human products, studies involving the highly purified bovine preparation, or placebo-controlled studies involving bovine thrombin were found. In a Phase III comparison of human recombinant thrombin and

  5. Control strategy of wind turbine based on permanent magnet synchronous generator and energy storage for stand-alone systems

    DEFF Research Database (Denmark)

    Deng, Fujin; Liu, Dong; Chen, Zhe

    2017-01-01

    This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system. An energy storage system(ESS) including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power...... converter through the power electronics interface. Wind is the primary power source of the system, the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system, respectively. In this paper, a control strategy is proposed...... for the operation of this variable speed wind turbine in a stand-alone system, where the generator-side converter and the ESS operate together to meet the demand of the loads. This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full...

  6. Optimum autonomous stand-alone photovoltaic system design on the basis of energy pay-back analysis

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Zafirakis, D.; Kondili, E.

    2009-01-01

    Stand-alone photovoltaic (PV) systems comprise one of the most promising electrification solutions for covering the demand of remote consumers. However, such systems are strongly questioned due to extreme life-cycle (LC) energy requirements. For similar installations to be considered as environmentally sustainable, their LC energy content must be compensated by the respective useful energy production, i.e. their energy pay-back period (EPBP) should be found less than their service period. In this context, an optimum sizing methodology is currently developed, based on the criterion of minimum embodied energy. Various energy autonomous stand-alone PV-lead-acid battery systems are examined and two different cases are investigated; a high solar potential area and a medium solar potential area. By considering that the PV-battery (PV-Bat) system's useful energy production is equal to the remote consumer's electricity consumption, optimum cadmium telluride (CdTe) based systems yield the minimum EPBP (15 years). If achieving to exploit the net PV energy production however, the EPBP is found less than 20 years for all PV types. Finally, the most interesting finding concerns the fact that in all cases examined the contribution of the battery component exceeds 27% of the system LC energy requirements, reflecting the difference between grid-connected and stand-alone configurations.

  7. A Case Study of Control and Improved Simplified Swarm Optimization for Economic Dispatch of a Stand-Alone Modular Microgrid

    Directory of Open Access Journals (Sweden)

    Xianyong Zhang

    2018-03-01

    Full Text Available Due to the complex configuration and control framework, the conventional microgrid is not cost-effective for engineering applications with small or medium capacity. A stand-alone modular microgrid with separated AC bus and decentralized control strategy is proposed in this paper. Each module is a self-powered system, which consists of wind and solar power, a storage battery, load and three-port converter. The modules are interconnected by three-port converters to form the microgrid. Characteristics, operation principle, control of the modular microgrid and the three-port converter are analyzed in detail. Distributed storage batteries enable power exchanges among modules to enhance economic returns. Economic dispatch of the stand-alone modular microgrid is a mixed-integer programming problem. A day-ahead operation optimization model including fuel cost, battery operation cost, and power transmission cost is established. Because there are so many constraints, it is difficult to produce a feasible solution and even more difficult to have an improved solution. An improved simplified swarm optimization (iSSO method is therefore proposed. The iSSO scheme designs the new update mechanism and survival of the fittest policy. The experimental results from the demonstration project on DongAo Island reflect the effectiveness of the stand-alone modular microgrid and the economic dispatch strategy based on the iSSO method.

  8. A New Vector Control of Brushless Doubly-Fed Inductor Generator With Transient Current Compensation for Stand-Alone Power Generation Applications

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Yu, Kailiang

    2018-01-01

    The stand-alone brushless doubly-fed induction generator (BDFIG) with the conventional control strategies suffers heavily from poor dynamic performance especially under heavy load disturbance. This paper presents a new vector control strategy of BDFIG for stand-alone power generation applications...... control strategies, and the results verify the satisfactory dynamic performance of the proposed strategy....

  9. New control strategy of stand-alone brushless doubly-fed induction generator for supplying unbalanced loads in ship shaft power generation system

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The ship shaft power generation system based on a stand-alone brushless doubly-fed induction generator (BDFIG) have demonstrated excellent saving-energy performance. This paper presents a new control scheme of the stand-alone BDFIG for supplying unbalanced loads in the ship shaft power generation...

  10. Maintenance of Segmental Lordosis and Disk Height in Stand-alone and Instrumented Extreme Lateral Interbody Fusion (XLIF).

    Science.gov (United States)

    Malham, Gregory M; Ellis, Ngaire J; Parker, Rhiannon M; Blecher, Carl M; White, Rohan; Goss, Ben; Seex, Kevin A

    2017-03-01

    A prospective single-surgeon nonrandomized clinical study. To evaluate the radiographic and clinical outcomes, by fixation type, in extreme lateral interbody fusion (XLIF) patients and provide an algorithm for determining patients suitable for stand-alone XLIF. XLIF may be supplemented with pedicle screw fixation, however, since stabilizing structures remain intact, it is suggested that stand-alone XLIF can be used for certain indications. This eliminates the associated morbidity, though subsidence rates may be elevated, potentially minimizing the clinical benefits. A fixation algorithm was developed after evaluation of patient outcomes from the surgeon's first 30 cases. This algorithm was used prospectively for 40 subsequent patients to determine the requirement for supplemental fixation. Preoperative, postoperative, and 12-month follow-up computed tomography scans were measured for segmental and global lumbar lordosis and posterior disk height. Clinical outcome measures included back and leg pain (visual analogue scale), Oswestry Disability Index (ODI), and SF-36 physical and mental component scores (PCS and MCS). Preoperatively to 12-month follow-up there were increases in segmental lordosis (7.9-9.4 degrees, P=0.0497), lumbar lordosis (48.8-55.2 degrees, P=0.0328), and disk height (3.7-5.5 mm, P=0.0018); there were also improvements in back (58.6%) and leg pain (60.0%), ODI (44.4%), PCS (56.7%), and MCS (16.1%) for stand-alone XLIF. For instrumented XLIF, segmental lordosis (7.6-10.5 degrees, P=0.0120) and disk height (3.5-5.6 mm, Plordosis decreased (51.1-45.8 degrees, P=0.2560). Back (49.8%) and leg pain (30.8%), ODI (32.3%), PCS (37.4%), and MCS (2.0%) were all improved. Subsidence occurred in 3 (7.5%) stand-alone patients. The XLIF treatment fixation algorithm provided a clinical pathway to select suitable patients for stand-alone XLIF. These patients achieved positive clinical outcomes, satisfactory fusion rates, with sustained correction of lordosis and

  11. Stand-Alone Personalized Normative Feedback for College Student Drinkers: A Meta-Analytic Review, 2004 to 2014.

    Directory of Open Access Journals (Sweden)

    Keri B Dotson

    Full Text Available Norms clarification has been identified as an effective component of college student drinking interventions, prompting research on norms clarification as a single-component intervention known as Personalized Normative Feedback (PNF. Previous reviews have examined PNF in combination with other components but not as a stand-alone intervention.To investigate the degree to which computer-delivered stand-alone personalized normative feedback interventions reduce alcohol consumption and alcohol-related harms among college students and to compare gender-neutral and gender-specific PNF.Electronic databases were searched systematically through November 2014. Reference lists were reviewed manually and forward and backward searches were conducted.Outcome studies that compared computer-delivered, stand-alone PNF intervention with an assessment only, attention-matched, or active treatment control and reported alcohol use and harms among college students.Between-group effect sizes were calculated as the standardized mean difference in change scores between treatment and control groups divided by pooled standard deviation. Within-group effect sizes were calculated as the raw mean difference between baseline and follow-up divided by pooled within-groups standard deviation.Eight studies (13 interventions with a total of 2,050 participants were included. Compared to control participants, students who received gender-neutral (dbetween = 0.291, 95% CI [0.159, 0.423] and gender-specific PNF (dbetween = 0.284, 95% CI [0.117, 0.451] reported greater reductions in drinking from baseline to follow-up. Students who received gender-neutral PNF reported 3.027 (95% CI [2.171, 3.882] fewer drinks per week at first follow-up and gender-specific PNF reported 3.089 (95% CI [0.992, 5.186] fewer drinks. Intervention effects were small for harms (dbetween = 0.157, 95% CI [0.037, 0.278].Computer-delivered PNF is an effective stand-alone approach for reducing college student

  12. Stand-Alone Personalized Normative Feedback for College Student Drinkers: A Meta-Analytic Review, 2004 to 2014.

    Science.gov (United States)

    Dotson, Keri B; Dunn, Michael E; Bowers, Clint A

    2015-01-01

    Norms clarification has been identified as an effective component of college student drinking interventions, prompting research on norms clarification as a single-component intervention known as Personalized Normative Feedback (PNF). Previous reviews have examined PNF in combination with other components but not as a stand-alone intervention. To investigate the degree to which computer-delivered stand-alone personalized normative feedback interventions reduce alcohol consumption and alcohol-related harms among college students and to compare gender-neutral and gender-specific PNF. Electronic databases were searched systematically through November 2014. Reference lists were reviewed manually and forward and backward searches were conducted. Outcome studies that compared computer-delivered, stand-alone PNF intervention with an assessment only, attention-matched, or active treatment control and reported alcohol use and harms among college students. Between-group effect sizes were calculated as the standardized mean difference in change scores between treatment and control groups divided by pooled standard deviation. Within-group effect sizes were calculated as the raw mean difference between baseline and follow-up divided by pooled within-groups standard deviation. Eight studies (13 interventions) with a total of 2,050 participants were included. Compared to control participants, students who received gender-neutral (dbetween = 0.291, 95% CI [0.159, 0.423]) and gender-specific PNF (dbetween = 0.284, 95% CI [0.117, 0.451]) reported greater reductions in drinking from baseline to follow-up. Students who received gender-neutral PNF reported 3.027 (95% CI [2.171, 3.882]) fewer drinks per week at first follow-up and gender-specific PNF reported 3.089 (95% CI [0.992, 5.186]) fewer drinks. Intervention effects were small for harms (dbetween = 0.157, 95% CI [0.037, 0.278]). Computer-delivered PNF is an effective stand-alone approach for reducing college student drinking and

  13. An optimized Fuzzy Logic Controller by Water Cycle Algorithm for power management of Stand-alone Hybrid Green Power generation

    International Nuclear Information System (INIS)

    Sarvi, Mohammad; Avanaki, Isa Nasiri

    2015-01-01

    Highlights: • A new method to improve the performance of renewable power management is proposed. • The proposed method is based on Fuzzy Logic optimized by the Water Cycle Algorithm. • The proposed method characteristics are compared with two other methods. • The comparisons confirm that the proposed method is robust and effectiveness one. - Abstract: This paper aims to improve the power management system of a Stand-alone Hybrid Green Power generation based on the Fuzzy Logic Controller optimized by the Water Cycle Algorithm. The proposed Stand-alone Hybrid Green Power consists of wind energy conversion and photovoltaic systems as primary power sources and a battery, fuel cell, and Electrolyzer as energy storage systems. Hydrogen is produced from surplus power generated by the wind energy conversion and photovoltaic systems of Stand-alone Hybrid Green Power and stored in the hydrogen storage tank for fuel cell later using when the power generated by primary sources is lower than load demand. The proposed optimized Fuzzy Logic Controller based power management system determines the power that is generated by fuel cell or use by Electrolyzer. In a hybrid system, operation and maintenance cost and reliability of the system are the important issues that should be considered in studies. In this regard, Water Cycle Algorithm is used to optimize membership functions in order to simultaneously minimize the Loss of Power Supply Probability and operation and maintenance. The results are compared with the particle swarm optimization and the un-optimized Fuzzy Logic Controller power management system to prove that the proposed method is robust and effective. Reduction in Loss of Power Supply Probability and operation and maintenance, are the most advantages of the proposed method. Moreover the level of the State of Charge of the battery in the proposed method is higher than other mentioned methods which leads to increase battery lifetime.

  14. Hierarchical energy management system for stand-alone hybrid system based on generation costs and cascade control

    International Nuclear Information System (INIS)

    Torreglosa, J.P.; García, P.; Fernández, L.M.; Jurado, F.

    2014-01-01

    Highlights: • We present an energy management system for a stand-alone WT/PV/hydrogen/battery hybrid system. • Hierarchical control composed by master and slave control strategies. • Control assures reliable electricity support for stand-alone applications subject to technical and economic criteria. - Abstract: This paper presents an energy management system (EMS) for stand-alone hybrid systems composed by photovoltaic (PV) solar panels and a wind turbine (WT) as primary energy sources and two energy storage systems, which are a hydrogen system and a battery. The hydrogen system is composed of fuel cell (FC), electrolyzer and hydrogen storage tank. The EMS is a hierarchical control composed by a master control strategy and a slave control strategy. On the one hand, the master control generates the reference powers to meet several premises (such as to satisfy the load power demand, and to maintain the hydrogen tank level and the state of charge (SOC) of the battery between their target margins), taking also into account economic aspects to discriminate between using the battery or hydrogen system. On the other hand, the slave control modifies the reference powers generated by the master control according to the energy sources dynamic limitations, and maintains the DC bus voltage at its reference value. The models, implemented in MATLAB-Simulink environment, have been developed from commercially available components. To check the viability of the proposed EMS, two kinds of simulations were carried out: (1) A long-term simulation of 25 years (expected lifetime of the system) with a sample time of one hour to validate the master control of the EMS; and (2) A short-term simulation with sudden net power variations to validate the slave control of the EMS

  15. Efficiency of the hybrid solar-wind systems for electricity supply to the stand-alone sites

    International Nuclear Information System (INIS)

    Abdullaev, D.A.; Isaev, R.I.

    2000-01-01

    The features of stand-alone sites and principles of their electricity supply is described there is going observation of the works about conditions of production and efficiency of using autonomy wind turbines and photovoltaics. Their unsufficiency is estimated. The advantages of hybrid systems and their realization schemes is described. The advantage of hybrid solar-wind Battery system (HSWBS) on the basis of own researches and the facts of other authors are given. The conception overall discounting cost is developed on HSWBS case. (Author)

  16. Evaluation of a proper controller performance for maximum-power point tracking of a stand-alone PV system

    Energy Technology Data Exchange (ETDEWEB)

    Nafeh, A.E.-S.A.; Fahmy, F.H. [Electronics Research Institute, Cairo (Egypt); El-Zahab, E.M.A. [Cairo University, Giza (Egypt). Faculty of Engineering

    2003-02-01

    In this paper the implementation of a suggested stand-alone PV system, for maximum-power point tracking (MPPT), is carried out. Also, this paper presents a comparative study, through experimental work, between the conventional PI controller and the fuzzy logic controller (FLC) under different atmospheric conditions. The implemented system with both the PI controller and the FLC gives a good maximum-power operation of the PV array, but the tracking capability for different optimum operating points is better and faster for the case of using the FLC compared to the case of using the PI controller. (author)

  17. United States housing, second quarter 2013

    Science.gov (United States)

    Delton Alderman

    2017-01-01

    The U.S. housing market’s quarter two results were disap¬pointing compared with the first quarter. Although overall expected gains did not materialize, certain sectors improved slightly. Housing under construction, completions, and new and existing home sales exhibited slight increases. Overall permit data declined, and the decrease in starts was due primarily to a...

  18. GOssTo: a stand-alone application and a web tool for calculating semantic similarities on the Gene Ontology.

    Science.gov (United States)

    Caniza, Horacio; Romero, Alfonso E; Heron, Samuel; Yang, Haixuan; Devoto, Alessandra; Frasca, Marco; Mesiti, Marco; Valentini, Giorgio; Paccanaro, Alberto

    2014-08-01

    We present GOssTo, the Gene Ontology semantic similarity Tool, a user-friendly software system for calculating semantic similarities between gene products according to the Gene Ontology. GOssTo is bundled with six semantic similarity measures, including both term- and graph-based measures, and has extension capabilities to allow the user to add new similarities. Importantly, for any measure, GOssTo can also calculate the Random Walk Contribution that has been shown to greatly improve the accuracy of similarity measures. GOssTo is very fast, easy to use, and it allows the calculation of similarities on a genomic scale in a few minutes on a regular desktop machine. alberto@cs.rhul.ac.uk GOssTo is available both as a stand-alone application running on GNU/Linux, Windows and MacOS from www.paccanarolab.org/gossto and as a web application from www.paccanarolab.org/gosstoweb. The stand-alone application features a simple and concise command line interface for easy integration into high-throughput data processing pipelines. © The Author 2014. Published by Oxford University Press.

  19. SedInConnect: a stand-alone, free and open source tool for the assessment of sediment connectivity

    Science.gov (United States)

    Crema, Stefano; Cavalli, Marco

    2018-02-01

    There is a growing call, within the scientific community, for solid theoretic frameworks and usable indices/models to assess sediment connectivity. Connectivity plays a significant role in characterizing structural properties of the landscape and, when considered in combination with forcing processes (e.g., rainfall-runoff modelling), can represent a valuable analysis for an improved landscape management. In this work, the authors present the development and application of SedInConnect: a free, open source and stand-alone application for the computation of the Index of Connectivity (IC), as expressed in Cavalli et al. (2013) with the addition of specific innovative features. The tool is intended to have a wide variety of users, both from the scientific community and from the authorities involved in the environmental planning. Thanks to its open source nature, the tool can be adapted and/or integrated according to the users' requirements. Furthermore, presenting an easy-to-use interface and being a stand-alone application, the tool can help management experts in the quantitative assessment of sediment connectivity in the context of hazard and risk assessment. An application to a sample dataset and an overview on up-to-date applications of the approach and of the tool shows the development potential of such analyses. The modelled connectivity, in fact, appears suitable not only to characterize sediment dynamics at the catchment scale but also to integrate prediction models and as a tool for helping geomorphological interpretation.

  20. Improved double integral sliding mode MPPT controller based parameter estimation for a stand-alone photovoltaic system

    International Nuclear Information System (INIS)

    Chatrenour, Nasrin; Razmi, Hadi; Doagou-Mojarrad, Hasan

    2017-01-01

    Highlights: • IDISMC based MPPT algorithm is introduced. • Hurwitz stability theorem is used for switching surface coefficients computation. • GA approach is presented for parameter estimation of the stand-alone PV system. - Abstract: In this paper, an Improved Double Integral Sliding Mode MPPT Controller (IDISMC) for a stand-alone photovoltaic (PV) system is proposed. Performance of a sliding mode controller (SMC) is greatly influenced by the choice of the sliding surface. Switching surface coefficients were selected by the use of Hurwitz stability theorem. The IDISMC not only is robust against parametric and non-parametric uncertainties, but also has a very small steady-state error, thanks to the use of double integral of tracking voltage error in the definition of its sliding surface. For realistic simulation, Genetic Algorithm (GA) method was used to estimate parameters of solar panels model. The validity of the proposed double integral SMC in maximum power point tracking was approved by comparing the simulation results obtained for a sample PV system with the results of other methods.

  1. Economic and Environmental Assessment of a Renewable Stand-Alone Energy Supply System Using Multi-objective Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dohyun; Han, Seulki; Kim, Jiyong Kim [Incheon National University, Incheon (Korea, Republic of)

    2017-06-15

    This study aims to propose a new optimization-based approach for design and analysis of the stand-alone hybrid energy supply system using renewable energy sources (RES). In the energy supply system, we include multiple energy production technologies such as Photovoltaics (PV), Wind turbine, and fossil-fuel-based AC generator along with different types of energy storage and conversion technologies such as battery and inverter. We then select six different regions of Korea to represent various characteristics of different RES potentials and demand profiles. We finally designed and analyzed the optimal RES stand-alone energy supply system in the selected regions using multiobjective optimization (MOOP) technique, which includes two objective functions: the minimum cost and the minimum CO{sub 2} emission. In addition, we discussed the feasibility and expecting benefits of the systems by comparing to conventional systems of Korea. As a result, the region of the highest RES potential showed the possibility to remarkably reduce CO{sub 2} emissions compared to the conventional system. Besides, the levelized cost of electricity (LCOE) of the RES-based energy system is identified to be slightly higher than conventional energy system: 0.35 and 0.46 $/kWh, respectively. However, the total life-cycle emission of CO{sub 2} (LCECO{sub 2}) can be reduced up to 470 gCO{sub 2}/kWh from 490 gCO{sub 2}/kWh of the conventional systems.

  2. Multi-objective optimal planning of the stand-alone microgrid system based on different benefit subjects

    International Nuclear Information System (INIS)

    Guo, Li; Wang, Nan; Lu, Hai; Li, Xialin; Wang, Chengshan

    2016-01-01

    As an important means to realize the energetic complementarity and improve the efficiency of renewable resources, the stand-alone microgrid (SAMG) system gains attention increasingly, especially in islands and remote areas. In this paper, considering the interest conflict of the distribution company and the distributed generation owner, a new multi-objective optimal planning model is formulated for medium voltage SAMG. Besides, to avoid the power constraint of distributed generation (DG) once the over-limit voltage occurs, a novel two-step power dispatch control method including the voltage regulation strategy is proposed, in which the absorption of distributed power by energy storage system (ESS) and the reactive power adjustment though its power control system are used to regulate voltage. The goal of this paper is to search the Pareto-optimal front of the site and capacity of DG as well as the contract price between both parties, and thus can provide effective references for practical planning of SAMG. Considering the high cost of ESS, the investment analysis of ESS is also discussed in the paper. - Highlights: • A multi-objective planning model based on different benefit subjects is proposed. • A two-step power dispatch method including the voltage regulation is proposed. • The economical efficiency of the proposed model is analyzed. • The effective reference for the stand-alone microgrid planning is provided.

  3. Optimization of the photovoltaic-hydrogen supply system of a stand-alone remote-telecom application

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Guillermo; Martinez, Graciano; Galvez, Jose L.; Cuevas, Raquel; Maellas, Jesus [National Institute for Aerospace Technology (INTA), Renewable Energy Department, Ctra. Ajalvir km 4, E-28850 Torrejon de Ardoz, Madrid (Spain); Gila, Raul; Bueno, Emilio [Polytechnical School - Alcala de Henares University, Electronics Department, Campus Universitario, Ctra. De Madrid-Barcelona Km 33.600, Alcala de Henares, Madrid (Spain)

    2009-07-15

    Hydrogen is considered as the optimal carrier for the surplus energy storage from renewable resources. Although hydrogen and its application in fuel cell is considered as a high-cost energy system, some cost-efficient solutions have been found for their use in stand-alone applications, which usually depend on the variability of renewable sources that have to be oversized in order to reduce their dependence on external energy sources. This paper shows the results from the simulation of several alternatives of introducing hydrogen technologies to increase the independence of a remote-telecom application fed by photovoltaic panels. Hydrogen is obtained by electrolysis and it is used in a fuel cell when the renewable energy source is not enough to maintain the stand-alone application. TRNSYS simulation environment has been used for evaluating the proposed alternatives. The results show that the best configuration option is that considering the use of hydrogen as a way to storage the surplus of radiation and the management system can vary the number of photovoltaic panels assigned to feed the hydrogen generation, the batteries or the telecom application. (author)

  4. Human microRNA target analysis and gene ontology clustering by GOmir, a novel stand-alone application.

    Science.gov (United States)

    Roubelakis, Maria G; Zotos, Pantelis; Papachristoudis, Georgios; Michalopoulos, Ioannis; Pappa, Kalliopi I; Anagnou, Nicholas P; Kossida, Sophia

    2009-06-16

    microRNAs (miRNAs) are single-stranded RNA molecules of about 20-23 nucleotides length found in a wide variety of organisms. miRNAs regulate gene expression, by interacting with target mRNAs at specific sites in order to induce cleavage of the message or inhibit translation. Predicting or verifying mRNA targets of specific miRNAs is a difficult process of great importance. GOmir is a novel stand-alone application consisting of two separate tools: JTarget and TAGGO. JTarget integrates miRNA target prediction and functional analysis by combining the predicted target genes from TargetScan, miRanda, RNAhybrid and PicTar computational tools as well as the experimentally supported targets from TarBase and also providing a full gene description and functional analysis for each target gene. On the other hand, TAGGO application is designed to automatically group gene ontology annotations, taking advantage of the Gene Ontology (GO), in order to extract the main attributes of sets of proteins. GOmir represents a new tool incorporating two separate Java applications integrated into one stand-alone Java application. GOmir (by using up to five different databases) introduces miRNA predicted targets accompanied by (a) full gene description, (b) functional analysis and (c) detailed gene ontology clustering. Additionally, a reverse search initiated by a potential target can also be conducted. GOmir can freely be downloaded BRFAA.

  5. Study on Soft Phase Locked Method to Solving the Synchronization Problem of Active Power Filter in Stand-alone Power Grid

    DEFF Research Database (Denmark)

    Zhuo, Fang; Wu, Longhui; Chen, Zhe

    2009-01-01

    on zero-cross detection can't work effectively in small rating stand-alone power grid. Then a soft phase locked loop with additional filter is proposed. It can lock the phase angle on to the positive sequence of fundamental voltage accurately and rapidly. It ensures the performance of APF applied...... in the small rating stand-alone power grid. Moreover, the soft phase locked loop is easy to be implemented in a Digital Signal Processor (DSP). Simulation and experimental results validate that the soft phase locked loop has satisfactory performance.......Traditional LC filters can't work stably in small rating stand-alone power grid. So active power filter (APF) is becoming an important tool to solve the power quality problem in small rating stand-alone power grid. In most current detection algorithm of APF, it needs a synchronizing signal. Firstly...

  6. Development of stand-alone risk assessment software for optimized maintenance planning of power plant facilities

    International Nuclear Information System (INIS)

    Choi, Woo Sung; Song, Gee Wook; Kim, Bum Shin; Chang, Sung Ho; Lee, Sang Min

    2015-01-01

    Risk-Risk-based inspection (RBI) has been developed in order to identify risky equipment that can cause major accidents or damages in large-scale plants. This assessment evaluates the equipment's risk, categorizes their priorities based on risk level, and then determines the urgency of their maintenance or allocates maintenance resources. An earlier version of the risk-based assessment software is already installed within the equipment management system; however, the assessment is based on examination by an inspector, and the results can be influenced by his subjective judgment, rather than assessment being based on failure probability. Moreover, the system is housed within a server, which limits the inspector's work space and time, and such a system can be used only on site. In this paper, the development of independent risk-based assessment software is introduced; this software calculates the failure probability by an analytical method, and analyzes the field inspection results, as well as inspection effectiveness. It can also operate on site, since it can be installed on an independent platform, and has the ability to generate an I/O function for the field inspection results regarding the period for an optimum maintenance cycle. This program will provide useful information not only to the field users who are participating in maintenance, but also to the engineers who need to decide whether to extend the life cycle of the power machinery or replace only specific components

  7. Clinical and radiological outcome after anterior cervical discectomy and fusion with stand-alone empty polyetheretherketone (PEEK) cages.

    Science.gov (United States)

    Shiban, Ehab; Gapon, Karina; Wostrack, Maria; Meyer, Bernhard; Lehmberg, Jens

    2016-02-01

    To evaluate long-term results after one-, two-, and three-level anterior cervical discectomy and fusion (ACDF) with stand-alone empty polyetheretherketone (PEEK) cages. We performed a retrospective review of a consecutive patient cohort that underwent ACDF with stand-alone empty PEEK cages between 2007 and 2010 with a minimum follow-up of 12 months. Radiographic follow-up included static and flexion/extension radiographs. Changes in the operated segments were measured and compared to radiographs directly after surgery. Clinical outcome was evaluated by a physical examination, pain visual analog scale (VAS), and health-related quality of life (HRQL) using the EuroQOL questionnaire (EQ-5D). Analysis of associations between fusion, subsidence, cervical alignment, and clinical outcome parameters were performed. Of 407 consecutive cases, 318 met all inclusion criteria. Follow-up data were obtained from 265 (83 %) cases. The mean age at presentation was 55 years and 139 patients were male (52 %). In the sample, 127, 125, and 13 patients had one-, two-, and three-level surgeries, respectively; 132 (49 %) presented with spondylotic cervical myelopathy and 133 (50 %) with cervical radiculopathy. Fusion was achieved in 85, 95, and 94 % of segments in one-, two-, and three-level surgeries, respectively. Non-fusion was associated with higher VAS pain levels. Radiographic adjacent segment disease (ASD) was observed in 20, 29, and 15 % in one-, two-, and three-level surgeries, respectively. ASD was associated with lower HRQL. Subsidence was observed in 25, 27, and 15 % of segments in one-, two-, and three-level surgeries, respectively. However, this had no influence on clinical outcome. Follow-up operations for symptomatic adjacent disc disease and implant failure at index level were needed in 16 (6 %) and four (1.5 %) cases, respectively. Younger age was associated with better clinical outcome. Multilevel surgery favored better myelopathy outcomes and fusion reduced overall

  8. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners.

    Science.gov (United States)

    Batterman, S; Du, L; Mentz, G; Mukherjee, B; Parker, E; Godwin, C; Chin, J-Y; O'Toole, A; Robins, T; Rowe, Z; Lewis, T

    2012-06-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and

  9. Optimal Sizing and Operation of Stand-Alone Hybrid Power Systems

    DEFF Research Database (Denmark)

    Kyriakidis, Ioannis; Chaudhary, Sanjay; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    for autonomous applications. Based on the island’s wind and solar potential, wind and solar systems appear as the most competitive solution while battery technologies provide the most feasible option for storing the excess energy. In the next, simulation models are developed in HOMER software. Various ratings...... of Renewable Energy Sources and Energy Storage Systems are considered and the most feasible combinations with respect to the Net Present Cost are calculated. The results have been assessed according to three scenarios, each of them representing a different policy and encountering several constraints....... Afterwards, steady-state analysis of the network is carried out considering typical cases of seasonal demand. The static model is developed in DIgSILENT PowerFactory software and the system’s behavior is investigated. In the following, the optimal placement for the wind, solar and storage units is discussed...

  10. Stand alone power system coupling a PV field and a fuel cell: first experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Busquet, S.; Labbe, J.; Leroux, P.; Metkemeijer, R.; Mayer, D. [ENSMP-CENERG, Sophia Antipolis (France)

    2003-07-01

    The purpose of the work, through the PVFC-SYS project, is to optimise the operation of a system coupling a photovoltaic field, an electrolyser, a gas storage, a fuel cell and a power management unit. A test bench is at present finalised in the Laboratory. All components have been selected for an optimal, automatic, safe and reliable operation of the complete system. Fully instrumented, this test bench furnishes new data concerning each component and the complete system behaviour for variable real weather conditions and different load demands. The paper describes the test bench, the simulation tool based on empirical model fitted to the component experimental data and the complete system performance for different load profiles along a year of operation. (orig.)

  11. An Approach for High-precision Stand-alone Positioning in a Dynamic Environment

    Science.gov (United States)

    Halis Saka, M.; Metin Alkan, Reha; Ozpercin, Alişir

    2015-04-01

    In this study, an algorithm is developed for precise positioning in dynamic environment utilizing a single geodetic GNSS receiver using carrier phase data. In this method, users should start the measurement on a known point near the project area for a couple of seconds making use of a single dual-frequency geodetic-grade receiver. The technique employs iono-free carrier phase observations with precise products. The equation of the algorithm is given below; Sm(t(i+1))=SC(ti)+[ΦIF (t(i+1) )-ΦIF (ti)] where, Sm(t(i+1)) is the phase-range between satellites and the receiver, SC(ti) is the initial range computed from the initial known point coordinates and the satellite coordinates and ΦIF is the ionosphere-free phase measurement (in meters). Tropospheric path delays are modelled using the standard tropospheric model. To accomplish the process, an in-house program was coded and some functions were adopted from Easy-Suite available at http://kom.aau.dk/~borre/easy. In order to assess the performance of the introduced algorithm in a dynamic environment, a dataset from a kinematic test measurement was used. The data were collected from a kinematic test measurement in Istanbul, Turkey. In the test measurement, a geodetic dual-frequency GNSS receiver, Ashtech Z-Xtreme, was set up on a known point on the shore and a couple of epochs were recorded for initialization. The receiver was then moved to a vessel and data were collected for approximately 2.5 hours and the measurement was finalized on a known point on the shore. While the kinematic measurement on the vessel were carried out, another GNSS receiver was set up on a geodetic point with known coordinates on the shore and data were collected in static mode to calculate the reference trajectory of the vessel using differential technique. The coordinates of the vessel were calculated for each measurement epoch with the introduced method. With the purpose of obtaining more robust results, all coordinates were calculated

  12. Military Family Housing in the United States

    Science.gov (United States)

    1993-09-01

    Deborah Clay- Mendez of CBO’s National Security Division and Lisa Siegel of CBO’s Budget Analysis Division prepared the study under the general...Aging of DoD’s Housing Beaufort Marine Corps Air Station in South Caro - Stock hna. (Photo courtesy of the General Accounting Office) DoD uses the

  13. Online retrieval of patient information by asynchronous communication between general purpose computer and stand-alone personal computer

    International Nuclear Information System (INIS)

    Tsutsumi, Reiko; Takahashi, Kazuei; Sato, Toshiko; Komatani, Akio; Yamaguchi, Koichi

    1988-01-01

    Asynchronous communication was made between host (FACOM M-340) and personal computer (OLIBETTIE S-2250) to get patient's information required for RIA test registration. The retrieval system consists of a keyboad input of six numeric codes, patient's ID, and a real time reply containing six parameters for the patient. Their identified parameters are patient's name, sex, date of birth (include area), department, and out- or inpatient. Linking this program to RIA registration program for individual patient, then, operator can input name of RIA test requested. Our simple retrieval program made a useful data network between different types of host and stand-alone personal computers, and enabled us accurate and labor-saving registration for RIA test. (author)

  14. Integration of hydrogen energy technologies in stand-alone power systems analysis of the current potential for applications

    International Nuclear Information System (INIS)

    Zoulias, E.I.; Lymberopoulos, N.; Tsoutsos, T.; Glockner, R.; Mydske, H.J.; Vosseler, I.; Gavalda, O.; Taylor, P.

    2006-01-01

    The European study entitled: 'Market Potential Analysis for Introduction of Hydrogen Energy Technology in Stand-Alone Power Systems (H-SAPS)' aimed to establish a broad understanding of the market potential for H-SAPS and provide a basis for promoting in wide scale new technological applications. The scope of the study was limited to small and medium installations, up to a few hundred kW power rating and based on RE as the primary energy source. The potential for hydrogen technology in SAPS was investigated through an assessment of the technical potential for hydrogen, the market analysis and the evaluation of external factors. The results are mostly directed towards action by governments and the research community but also industry involvement is identified. The results include targeted market research, establishment of individual cost targets, regulatory changes to facilitate alternative grid solutions, information and capacity building, focused technology research and bridging the technology gaps. (author)

  15. A soil-canopy scheme for use in a numerical model of the atmosphere: 1D stand-alone model

    Science.gov (United States)

    Kowalczyk, E. A.; Garratt, J. R.; Krummel, P. B.

    We provide a detailed description of a soil-canopy scheme for use in the CSIRO general circulation models (GCMs) (CSIRO-4 and CSIRO-9), in the form of a one-dimensional stand-alone model. In addition, the paper documents the model's ability to simulate realistic surface fluxes by comparison with mesoscale model simulations (involving more sophisticated soil and boundary-layer treatments) and observations, and the diurnal range in surface quantities, including extreme maximum surface temperatures. The sensitivity of the model to values of the surface resistance is also quantified. The model represents phase 1 of a longer-term plan to improve the atmospheric boundary layer (ABL) and surface schemes in the CSIRO GCMs.

  16. Rancang Bangun Stand-Alone Automatic Rain Gauge (ARG Berbasis Panel Surya

    Directory of Open Access Journals (Sweden)

    Zaenal Arifin

    2017-11-01

    Full Text Available Automatic Rain Gauge (ARG digunakan untuk memonitor curah hujan di suatu wilayah. ARG bekerja dengan menggunakan mikrokontroller sebagai prosesing unit dan merupakan sebuah embedded sistem (sistem yang berdiri sendiri. ARG tidak hanya diletakan pada stasiun pemantauan Badan Meteorologi, Klimatologi dan Geofisika (BMKG, namun ARG juga diletakan di daerah terpencil yang jauh dari jaringan listrik. Hal tersebut menjadi masalah karena ARG membutuhkan sumber energi listrik untuk dapat bekerja. Berdasarkan spesifikasinya, ARG membutuhkan mikrokontroller yang rendah dalam penggunaan daya serta memiliki cukup memory sebagai tempat penyimpanan data sementara. Salah satu jenis mikrokrontroller yang memenuhi spesifikasi tersebut adalah MSP430FR5969. Dari penelitian yang telah dilakukan, didapatkan hasil konsumsi daya rata – rata yang dibutuhkan oleh ARG sebesar 0.23 watt. Dengan memanfaatkan panel surya sebesar 20 watt yang dilengkapi dengan maximum power point tracking (MPPT sebagai sumber energi listrik, dapat menghasilkan daya 5,5 watt hingga 7,2 watt. Dengan perbandingan data konsumsi energi dan data yang dihasilkan dari solar panel panel, maka ARG memiliki sumber listrik mandiri untuk memenuhi kebutuhannya.

  17. Continental United States Military Housing Inspections Southeast

    Science.gov (United States)

    2015-09-24

    that the HVAC system design used in the noncommissioned officer academy buildings at Fort Gordon was not appropriate or adequate for the climatic... HVAC ) system problems; mold; and moisture were not adequately addressed, resulting in poor indoor air quality and potential exposure of occupants to...Patrick AFB. 3 The number of military personnel occupying unaccompanied housing at NS Mayport fluctuates based on ship arrival and departure

  18. A case study of a typical 2.32 kW{sub P} stand-alone photovoltaic (SAPV) in composite climate of New Delhi (India)

    Energy Technology Data Exchange (ETDEWEB)

    Chel, Arvind; Tiwari, G.N. [Center for Energy Studies (CES), Indian Institute of Technology, Hauz Khas, New Delhi 110 016 (India)

    2011-04-15

    This paper presents rigorous experimental outdoor performance of a 2.32 kW{sub P} stand-alone photovoltaic (SAPV) system in New Delhi (India) for four weather types in each month such as clear, hazy, partially cloudy/foggy and fully cloudy/foggy weather conditions respectively. The daily power generated from the existing SAPV system was experimentally found in the range of 4-6 kW h/day depending on the prevailing sky conditions. The number of days and daily power generated corresponding to four weather types in each month were used to determine monthly and subsequently annual power generation from the existing SAPV system. There are three daily load profiles with and without earth to air heat exchanger suitable for three seasons like summer (3.75-6.15 kW h/day), winter (2.79-5.19 kW h/day) and rainy (3.75 kW h/day). The hourly efficiency of the SAPV system components are determined and presented in this paper. The life cycle cost (LCC) analysis for the existing typical SAPV system is carried out to determine unit cost of electricity. The effect of annual degradation rate of PV system efficiency is also presented in this paper. The energy production factor (EPF) and the energy payback time (EPBT) of the SAPV system was also determined and presented in this paper. (author)

  19. Leadership in Dental Hygiene Degree Completion Programs: A Pilot Study Comparing Stand-Alone Leadership Courses and Leadership-Infused Curricula.

    Science.gov (United States)

    Smith, Michelle L; Gurenlian, JoAnn R; Freudenthal, Jacqueline J; Farnsworth, Tracy J

    2016-05-01

    The aim of this study was to define the extent to which leadership and leadership skills are taught in dental hygiene degree completion programs by comparing stand-alone leadership courses/hybrid programs with programs that infuse leadership skills throughout the curricula. The study involved a mixed-methods approach using qualitative and quantitative data. Semi-structured interviews were conducted with program directors and faculty members who teach a stand-alone leadership course, a hybrid program, or leadership-infused courses in these programs. A quantitative comparison of course syllabi determined differences in the extent of leadership content and experiences between stand-alone leadership courses and leadership-infused curricula. Of the 53 U.S. dental hygiene programs that offer degree completion programs, 49 met the inclusion criteria, and 19 programs provided course syllabi. Of the program directors and faculty members who teach a stand-alone leadership course or leadership-infused curriculum, 16 participated in the interview portion of the study. The results suggested that competencies related to leadership were not clearly defined or measurable in current teaching. Reported barriers to incorporating a stand-alone leadership course included overcrowded curricula, limited qualified faculty, and lack of resources. The findings of this study provide a synopsis of leadership content and gaps in leadership education for degree completion programs. Suggested changes included defining a need for leadership competencies and providing additional resources to educators such as courses provided by the American Dental Education Association and the American Dental Hygienists' Association.

  20. Stand-alone microgrids

    NARCIS (Netherlands)

    Bauer, P.; Weldemariam, L.E.; Raijen, E.

    2011-01-01

    Abstract- A hybrid power system (HPS) which consists of diesel Genset, PV -arrays and wind turbines with energy storing and power electronic devices is discussed in this paper. An inventory of different connection topologies is made for some of the sources that generate AC power and others that

  1. A Novel Method for Fast Configuration of Energy Storage Capacity in Stand-Alone and Grid-Connected Wind Energy Systems

    Directory of Open Access Journals (Sweden)

    Haixiang Zang

    2016-12-01

    Full Text Available In this paper, a novel method is proposed and applied to quickly calculate the capacity of energy storage for stand-alone and grid-connected wind energy systems, according to the discrete Fourier transform theory. Based on practical wind resource data and power data, which are derived from the American Wind Energy Technology Center and HOMER software separately, the energy storage capacity of a stand-alone wind energy system is investigated and calculated. Moreover, by applying the practical wind power data from a wind farm in Fujian Province, the energy storage capacity for a grid-connected wind system is discussed in this paper. This method can also be applied to determine the storage capacity of a stand-alone solar energy system with practical photovoltaic power data.

  2. Development of a Laser-Powered Dielectric Structure-Based Accelerator as a Stand-Alone Particle Source

    International Nuclear Information System (INIS)

    Yoder, R. B.; Travish, G.; Arab, E. R.; Fong, D.; Hoyer, Z.; Lacroix, U. H.; Vartanian, N.; Rosenzweig, J. B.

    2010-01-01

    An experimental program to develop and build a dielectric-based slab-symmetric structure (the micro-accelerator platform, or MAP) for generating and accelerating low-energy electrons is underway at UCLA and Manhattanville College. This optical acceleration structure is effectively a resonant cavity powered by a side-coupled laser, and has applications as a radiation source for medicine or industry. We present recent experimental and computational results on the accelerator, and progress toward its incorporation into a self-contained particle source. Such a particle source would incorporate a micron-scale electron emitter and a non-relativistic capture region to enable self-injection into the synchronous field within the accelerator. A prototype of the accelerator itself has been constructed from candidate dielectric materials using micromanufacturing techniques; the current status of the testing program is described. A novel electron emitter incorporating pyroelectric crystals with field-enhancing tips has been demonstrated to produce steady currents; the results are dependent on tip geometry, and appear suitable for injection into a microstructure. Extension of the MAP concept to non-relativistic velocities, as in the stand-alone source, requires a tapered structure that gives rise to numerous complications including beam defocusing and manufacturing challenges; approaches for addressing these complications are mentioned.

  3. Adaptive Artificial intelligence based fuzzy logic MPPTcontrol for stande-alone photovoltaic system under different atmospheric conditions

    Directory of Open Access Journals (Sweden)

    Zaghba Layachi

    2015-08-01

    Full Text Available there is an increased need for analysing the effect of atmospheric variables on photovoltaic (PV production and performance. The outputs from the different PV cells in different atmospheric conditions, such as irradiation and temperature , differ from each other evidencing knowledge deficiency in PV systems [14]. Maximum power point tracking (MPPT methods are used to maximize the PV array output power by tracking continuously the maximum power point (MPP. Among all MPPT methods existing in the literature, perturb and observe (P&O is the most commonly used for its simplicity and ease of implementation; however, it presents drawbacks such as slow response speed, oscillation around the MPP in steady state, and even tracking in wrong way under rapidly changing atmospheric conditions. In order to allow a functioning around the optimal point Mopt, we have inserted a DC-DC converter (Buck–Boost for a better matching between the PV and the load. This paper, we study the Maximum power point tracking using adaptive Intelligent fuzzy logic and conventional (P&O control for stande-alone photovoltaic Array system .In particular, the performances of the controllers are analyzed under variation weather conditions with are constant temperature and variable irradiation. The proposed system is simulated by using MATLAB-SIMULINK. According to the results, fuzzy logic controller has shown better performance during the optimization.

  4. Stand-alone power systems for the future: Optimal design, operation and control of solar-hydrogen energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Ulleberg, Oeystein

    1999-12-31

    This thesis gives a systematic review of the fundamentals of energy systems, the governing physical and chemical laws related to energy, inherent characteristics of energy system, and the availability of the earth`s energy. It shows clearly why solar-hydrogen systems are one of the most viable options for the future. The main subject discussed is the modelling of SAPS (Stand-Alone Power Systems), with focus on photovoltaic-hydrogen energy systems. Simulation models for a transient simulation program are developed for PV-H{sub 2} components, including models for photovoltaics, water electrolysis, hydrogen storage, fuel cells, and secondary batteries. A PV-H{sub 2} demonstration plant in Juelich, Germany, is studied as a reference plant and the models validated against data from this plant. Most of the models developed were found to be sufficiently accurate to perform short-term system simulations, while all were more than accurate enough to perform long-term simulations. Finally, the verified simulation models are used to find the optimal operation and control strategies of an existing PV-H{sub 2} system. The main conclusion is that the simulation methods can be successfully used to find optimal operation and control strategies for a system with fixed design, and similar methods could be used to find alternative system designs. 148 refs., 78 figs., 31 tabs.

  5. Power fluctuations suppression of stand-alone hybrid generation combining solar photovoltaic/wind turbine and fuel cell systems

    International Nuclear Information System (INIS)

    Ahmed, Nabil A.; Miyatake, Masafumi; Al-Othman, A.K.

    2008-01-01

    In this paper a hybrid energy system combining variable speed wind turbine, solar photovoltaic and fuel cell generation systems is presented to supply continuous power to residential power applications as stand-alone loads. The wind and photovoltaic systems are used as main energy sources while the fuel cell is used as secondary or back-up energy source. Three individual dc-dc boost converters are used to control the power flow to the load. A simple and cost effective control with dc-dc converters is used for maximum power point tracking and hence maximum power extracting from the wind turbine and the solar photovoltaic systems. The hybrid system is sized to power a typical 2 kW/150 V dc load as telecommunication power plants or ac residential power applications in isolated islands continuously throughout the year. The results show that even when the sun and wind are not available; the system is reliable and available and it can supply high-quality power to the load. The simulation results which proved the accuracy of the proposed controllers are given to demonstrate the availability of the proposed system in this paper. Also, a complete description of the management and control system is presented

  6. A stand alone computer system to aid the development of mirror fusion test facility RF heating systems

    International Nuclear Information System (INIS)

    Thomas, R.A.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF-B) control system architecture requires the Supervisory Control and Diagnostic System (SCDS) to communicate with a LSI-11 Local Control Computer (LCC) that in turn communicates via a fiber optic link to CAMAC based control hardware located near the machine. In many cases, the control hardware is very complex and requires a sizable development effort prior to being integrated into the overall MFTF-B system. One such effort was the development of the Electron Cyclotron Resonance Heating (ECRH) system. It became clear that a stand alone computer system was needed to simulate the functions of SCDS. This paper describes the hardware and software necessary to implement the SCDS Simulation Computer (SSC). It consists of a Digital Equipment Corporation (DEC) LSI-11 computer and a Winchester/Floppy disk operating under the DEC RT-11 operating system. All application software for MFTF-B is programmed in PASCAL, which allowed us to adapt procedures originally written for SCDS to the SSC. This nearly identical software interface means that software written during the equipment development will be useful to the SCDS programmers in the integration phase

  7. Stand-alone power systems for the future: Optimal design, operation and control of solar-hydrogen energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Ulleberg, Oeystein

    1998-12-31

    This thesis gives a systematic review of the fundamentals of energy systems, the governing physical and chemical laws related to energy, inherent characteristics of energy system, and the availability of the earth`s energy. It shows clearly why solar-hydrogen systems are one of the most viable options for the future. The main subject discussed is the modelling of SAPS (Stand-Alone Power Systems), with focus on photovoltaic-hydrogen energy systems. Simulation models for a transient simulation program are developed for PV-H{sub 2} components, including models for photovoltaics, water electrolysis, hydrogen storage, fuel cells, and secondary batteries. A PV-H{sub 2} demonstration plant in Juelich, Germany, is studied as a reference plant and the models validated against data from this plant. Most of the models developed were found to be sufficiently accurate to perform short-term system simulations, while all were more than accurate enough to perform long-term simulations. Finally, the verified simulation models are used to find the optimal operation and control strategies of an existing PV-H{sub 2} system. The main conclusion is that the simulation methods can be successfully used to find optimal operation and control strategies for a system with fixed design, and similar methods could be used to find alternative system designs. 148 refs., 78 figs., 31 tabs.

  8. Modeling and control design of a stand alone wind energy conversion system based on functional model predictive control

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, Ahmed M. [Beni-Suef University, Electrical Dept., Beni Suef (Egypt)

    2012-09-15

    This paper investigates the application of the model predictive control (MPC) approach to control the voltage and frequency of a stand alone wind generation system. This scheme consists of a wind turbine which drives an induction generator feeding an isolated load. A static VAR compensator is connected at the induction generator terminals to regulate the load voltage. The rotor speed, and thereby the load frequency are controlled via adjusting the mechanical power input using the blade pitch-angle. The MPC is used to calculate the optimal control actions including system constraints. To alleviate computational effort and to reduce numerical problems, particularly in large prediction horizon, an exponentially weighted functional model predictive control (FMPC) is employed. Digital simulations have been carried out in order to validate the effectiveness of the proposed scheme. The proposed controller has been tested through step changes in the wind speed and the load impedance. Simulation results show that adequate performance of the proposed wind energy scheme has been achieved. Moreover, this scheme is robust against the parameters variation and eliminates the influence of modeling and measurement errors. (orig.)

  9. Modeling and Experimental Test of Grid-Tied Photovoltaic Cell Emulating System in the Stand-alone Mode

    Directory of Open Access Journals (Sweden)

    Vu Minh Phap

    2017-06-01

    Full Text Available In recent decades, generation of electricity from solar arrays has been increased to meet the world's growing energy demand. However, the utilization rate of the power conditioner in the grid-tied solar power system is low because the operation of solar panels is dependent on sunlight. Thus, we studied the method that the small scale wind power generating system in size from a few hundred watts to two or three kilowatts can be connected to the grid-tied power conditioner of the solar power system for residential applications with low power ratings (single phase, size is limited to 10kW by emulating characteristic of the solar panel. In this paper, we introduce the application of the grid-tied PV cell emulating system in the stand-alone mode to improve the utilization rate of the power conditioner. The simulation and experimental test results verify that the PV cell emulating system can operate the power conditioner of the gridtied solar power system.

  10. Multi-Objective Optimal Design of Stand-Alone Hybrid Energy System Using Entropy Weight Method Based on HOMER

    Directory of Open Access Journals (Sweden)

    Jiaxin Lu

    2017-10-01

    Full Text Available Implementation of hybrid energy system (HES is generally considered as a promising way to satisfy the electrification requirements for remote areas. In the present study, a novel decision making methodology is proposed to identify the best compromise configuration of HES from a set of feasible combinations obtained from HOMER. For this purpose, a multi-objective function, which comprises four crucial and representative indices, is formulated by applying the weighted sum method. The entropy weight method is employed as a quantitative methodology for weighting factors calculation to enhance the objectivity of decision-making. Moreover, the optimal design of a stand-alone PV/wind/battery/diesel HES in Yongxing Island, China, is conducted as a case study to validate the effectiveness of the proposed method. Both the simulation and optimization results indicate that, the optimization method is able to identify the best trade-off configuration among system reliability, economy, practicability and environmental sustainability. Several useful conclusions are given by analyzing the operation of the best configuration.

  11. Splitting Terraced Houses Into Single Units Using Oblique Aerial Imagery

    Science.gov (United States)

    Dahlke, D.

    2017-05-01

    This paper introduces a method to subdivide complex building structures like terraced houses into single house units comparable to units available in a cadastral map. 3D line segments are detected with sub-pixel accuracy in traditional vertical true orthomosaics as well as in innovative oblique true orthomosaics and their respective surface models. Hereby high gradient strengths on roofs as well as façades are taken into account. By investigating the coplanarity and frequencies within a set of 3D line segments, individual cut lines for a building complex are found. The resulting regions ideally describe single houses and thus the object complexity is reduced for subsequent topological, semantical or geometrical considerations. For the chosen study area with 70 buidling outlines a hit rate of 80% for cut lines is achieved.

  12. Techno-economic analysis of stand-alone photovoltaic/wind/battery/hydrogen systems for very small-scale applications

    Directory of Open Access Journals (Sweden)

    Stojković Saša M.

    2016-01-01

    Full Text Available The paper presents the results of a technical and economic analysis of three stand-alone hybrid power systems based on renewable energy sources which supply a specific group of low-power consumers. This particular case includes measuring sensors and obstacle lights on a meteorological mast for wind measurements requiring an uninterrupted power supply in cold climate conditions. Although these low-power (100 W measuring sensors and obstacle lights use little energy, their energy consumption is not the same as the available solar energy obtained on a daily or seasonal basis. In the paper, complementarity of renewable energy sources was analysed, as well as one of short-term lead-acid battery-based storage and seasonal, hydrogen-based (electrolyser, H2 tank, and fuel cells storage. These relatively complex power systems were proposed earlier for high-power consumers only, while this study specifically highlights the role of the hydrogen system for supplying low-power consumers. The analysis employed a numerical simulation method using the HOMER software tool. The results of the analysis suggest that solar and wind-solar systems, which involve meteorological conditions as referred to in this paper, include a relatively large number of lead-acid batteries. Additionally, the analysis suggests that the use of hydrogen power systems for supplying low power-consumers is entirely justifiable, as it significantly reduces the number of batteries (two at minimum in this particular case. It was shown that the increase in costs induced by the hydrogen system is acceptable.

  13. Energetic and financial investigation of a stand-alone solar-thermal Organic Rankine Cycle power plant

    International Nuclear Information System (INIS)

    Tzivanidis, Christos; Bellos, Evangelos; Antonopoulos, Kimon A.

    2016-01-01

    Highlights: • A stand-alone solar driven Organic Rankine Cycle is optimized parametrically. • The system is optimized energetically and financially. • Nine working fluids are tested with cyclohexane to be the most suitable. • A collecting area of 25,000 m"2 parabolic trough collectors is the optimum solution. • The maximum IRR is 13.46% and the payback period is about 9 years. - Abstract: The use of solar thermal energy for electricity production is a clean and sustainable way to cover the increasing energy needs of our society. The most mature technology for capturing solar energy in high temperature levels is the parabolic trough collectors (PTC). In this study, an Organic Rankine Cycle (ORC) coupled with PTC is analyzed parametrically in order to be optimized financially and energetically. The first step is the thermodynamic investigation of the ORC by using various working fluids. The second step is the energetic and financial investigation of the total system which includes the solar field, the storage tank and the ORC module. By testing many combinations of collecting areas and storage tank volumes, finally cyclohexane proved to be the most suitable working fluid for producing 1 MW_e_l with PTC. Specifically, in the optimum situation a solar field of 25,000 m"2 with storage tank of about 300 m"3 leads to a payback period of 9 years and to an internal rate of return (IRR) equal to 13.46%. Moreover, an economic comparison for different commercial collectors is presented, with Eurotrough ET-150 being the financially optimum solution for this case study.

  14. An adaptive artificial neural network model for sizing stand-alone photovoltaic systems: Application for isolated sites in Algeria

    International Nuclear Information System (INIS)

    Mellit, A.; Benghanem, M.; Hadj Arab, A.; Guessoum, G.

    2004-07-01

    In this paper we investigate, by using an adaptive Artificial Neural Network (ANN), in order to find a suitable model for sizing Stand-Alone Photovoltaic (SAPV) systems, based on a minimum of input data. This model combines Radial Basis Function (RBF) network and Infinite Impulse Response (IIR) filter in order to accelerate the convergence of the network. For the sizing of a photovoltaic (PV) system, we need to determine the optimal sizing coefficients (K PV , K B . These coefficients allow us to determine the number of solar panels and storage batteries necessary to satisfy a given consumption, especially in isolated sites where the global solar radiation data is not always available and which are considered the most important parameters for sizing a PV system. Obtained results by classical models (analytical, numerical, analytical- numerical, B-spline function) and new models like feed-forward (MLP), radial basis function (RBF), MLP-IIR and RBF-IIR have been compared with experimental sizing coefficients in order to illustrate the accuracy of the results of the new developed model. This model has been trained by using 200 known optimal sizing coefficients corresponding to 200 locations in Algeria. In this way, the adaptive model was trained to accept and even handle a number of unusual cases, the unknown validation sizing coefficients set produced very set accurate estimation and a correlation coefficient of 98% was obtained between the calculated and that estimated by the RBF-IIR model. This result indicates that the proposed method can be successfully used for the estimation of optimal sizing coefficients of SAPV systems for any locations in Algeria, but the methodology can be generalized using different locations over the world. (author)

  15. System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

    KAUST Repository

    Huang, B.J.

    2010-05-01

    The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m2. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). © 2010 Elsevier Ltd. All rights reserved.

  16. Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging.

    Science.gov (United States)

    Park, Jinhyoung; Hu, Changhong; Shung, K Kirk

    2011-12-01

    A stand-alone front-end system for high-frequency coded excitation imaging was implemented to achieve a wider dynamic range. The system included an arbitrary waveform amplifier, an arbitrary waveform generator, an analog receiver, a motor position interpreter, a motor controller and power supplies. The digitized arbitrary waveforms at a sampling rate of 150 MHz could be programmed and converted to an analog signal. The pulse was subsequently amplified to excite an ultrasound transducer, and the maximum output voltage level achieved was 120 V(pp). The bandwidth of the arbitrary waveform amplifier was from 1 to 70 MHz. The noise figure of the preamplifier was less than 7.7 dB and the bandwidth was 95 MHz. Phantoms and biological tissues were imaged at a frame rate as high as 68 frames per second (fps) to evaluate the performance of the system. During the measurement, 40-MHz lithium niobate (LiNbO(3)) single-element lightweight (<;0.28 g) transducers were utilized. The wire target measure- ment showed that the -6-dB axial resolution of a chirp-coded excitation was 50 μm and lateral resolution was 120 μm. The echo signal-to-noise ratios were found to be 54 and 65 dB for the short burst and coded excitation, respectively. The contrast resolution in a sphere phantom study was estimated to be 24 dB for the chirp-coded excitation and 15 dB for the short burst modes. In an in vivo study, zebrafish and mouse hearts were imaged. Boundaries of the zebrafish heart in the image could be differentiated because of the low-noise operation of the implemented system. In mouse heart images, valves and chambers could be readily visualized with the coded excitation.

  17. 24 CFR 983.54 - Prohibition of assistance for units in subsidized housing.

    Science.gov (United States)

    2010-04-01

    ..., DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT PROJECT-BASED VOUCHER (PBV) PROGRAM Selection of PBV Owner... PBV assistance to units in any of the following types of subsidized housing: (a) A public housing... operating costs of the housing; (e) A unit subsidized with Section 236 rental assistance payments (12 U.S.C...

  18. A compact seven switches topology and reduced DC-link capacitor size for single-phase stand-alone PV system with hybrid energy storages

    DEFF Research Database (Denmark)

    Liu, Xiong; Wang, Peng; Loh, Poh Chiang

    2011-01-01

    Single-phase stand-alone PV system is suitable for household applications in remote area. Hybrid battery/ultra-capacitor energy storage can reduce charge and discharge cycles and avoid deep discharges of battery. This paper proposes a compact seven switches structure for stand-alone PV system......, which otherwise needs nine switches configuration, inclusive of one switch for boost converter, four switches for single-phase inverter and four switches for two DC/DC converters of battery and ultra-capacitor. It is well-known that a bulky DC-link capacitor is always required to absorb second......-order harmonic current caused by single-phase inverter. In the proposed compact topology, a small size DC-link capacitor can achieve the same function through charging/discharging control of ultra-capacitor to mitigate second-order ripple current. Simulation results are provided to validate the effectiveness...

  19. SoC-Based Output Voltage Control for BESS with a Lithium-Ion Battery in a Stand-Alone DC Microgrid

    Directory of Open Access Journals (Sweden)

    Seung-Yeong Yu

    2016-11-01

    Full Text Available This paper proposes a new DC output voltage control for a battery energy storage system (BESS with a lithium-ion battery based on the state of charge (SoC. The proposed control scheme was verified through computer simulations for a typical stand-alone DC microgrid, which consists of a BESS, photovoltaic (PV panel, engine generator (EG, and DC load. A scaled hardware prototype for a stand-alone DC microgrid was set up in the lab, in which the proposed control scheme was loaded in a DSP controller. The experimental results were compared with the simulation results for performance verification. The proposed control scheme provides relatively lower variation of the DC grid voltage than the conventional droop control.

  20. Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysis

    Directory of Open Access Journals (Sweden)

    Hsieh Pang-Hsing

    2008-06-01

    Full Text Available Abstract Background Initial promise of a stand-alone interbody fusion cage to treat chronic back pain and restore disc height has not been realized. In some instances, a posterior spinal fixation has been used to enhance stability and increase fusion rate. In this manuscript, a new stand-alone cage is compared with conventional fixation methods based on the finite element analysis, with a focus on investigating cage-bone interface mechanics and stress distribution on the adjacent tissues. Methods Three trapezoid 8° interbody fusion cage models (dual paralleled cages, a single large cage, or a two-part cage consisting of a trapezoid box and threaded cylinder were created with or without pedicle screws fixation to investigate the relative importance of the screws on the spinal segmental response. The contact stress on the facet joint, slip displacement of the cage on the endplate, and rotational angle of the upper vertebra were measured under different loading conditions. Results Simulation results demonstrated less facet stress and slip displacement with the maximal contact on the cage-bone interface. A stand-alone two-part cage had good slip behavior under compression, flexion, extension, lateral bending and torsion, as compared with the other two interbody cages, even with the additional posterior fixation. However, the two-part cage had the lowest rotational angles under flexion and torsion, but had no differences under extension and lateral bending. Conclusion The biomechanical benefit of a stand-alone two-part fusion cage can be justified. This device provided the stability required for interbody fusion, which supports clinical trials of the cage as an alternative to circumferential fixations.

  1. Systematic Multi-variable H-infinity Control Design for Primary Frequency Regulation in Stand-alone Microgrids with High Penetration of Renewable Energy Sources

    OpenAIRE

    Lam , Quang Linh; Bratcu , Antoneta Iuliana; Riu , Delphine

    2016-01-01

    International audience; In this paper, a systematic design of a robust multi-variable control structure for primary frequency regulation in microgrids with high rate of renewable source penetration is proposed. The considered microgrid represents a diesel-photovoltaic-supercapacitor hybrid power generation system operating in stand-alone mode. The proposed control structure relies on a two-level architecture: classical PI-based current tracking controllers are placed on the low control level ...

  2. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A.; Campos, J. [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A. [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1997-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  3. Design of a small scale stand-alone solar thermal co-generation plant for an isolated region in Egypt

    International Nuclear Information System (INIS)

    Abdelhady, Suzan; Borello, Domenico; Tortora, Eileen

    2014-01-01

    Highlights: • In the selected area, connection to the grid is very difficult and expensive. • The integrated unsteady CSP/ORC system, was modeled TRNSYS. • Assuming a CSP of 200,000 m 2 , 6 MW e and 21.5 MW th can be obtained. • The energy is sufficient to feed more than 3,300 rural users and two big factories. • PER = 1.43, LCOE = 1.25 USD/kW h and the GHG emissions are reduced of 7300 toe/year. - Abstract: Most of Egypt’s population is concentrated in the Nile Valley (5% of Egypt’s area), while the western desert occupies an area of 50% of the total area of Egypt with a small number of inhabitants. The New Valley is the largest governorates in Egypt which occupies 45.8% of the total area of the Country and 65% of the Western Desert and it is the least densely populated governorate in Egypt. However, New Valley has started to receive the migrated people from the Nile valley and Delta region and the demand for the energy is continuously increasing. However, the rural area in New Valley still suffers from lack of access to energy services. The very high transmission losses and costs are the main challenges for electrification in this area. Then, it is worth to investigate the opportunities for distributed energy generation. This area of Egypt receives some of the highest solar radiation in the world (up to 3000 kW h per square meters per year), making it a prime location for use of this resource. In this study, performance and economic assessment of a small scale stand-alone solar thermal co-generation plant using diathermic oil is presented. This configuration is considered as a promising and sustainable solution to provide electricity and heat to an isolated area satisfying the local loads. Parabolic trough plant has been modeled in TRNSYS simulation environment integrated with the Solar Thermal Electric Components (STEC) model library. Both solar and power cycle performances have been modeled based on the solar energy data of the plant site. The

  4. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A; Campos, J [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1998-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  5. Designing Sustainable Urban Social Housing in the United Arab Emirates

    Directory of Open Access Journals (Sweden)

    Khaled Galal Ahmed

    2017-08-01

    Full Text Available The United Arab Emirates is experiencing a challenging turn towards sustainable social housing. Conventional neighborhood planning and design principles are being replaced by those leading to more sustainable urban forms. To trace this challenging move, the research has investigated the degree of consideration of sustainable urban design principles in two social housing neighborhoods in Al Ain City in Abu Dhabi Emirate, UAE. The first represents a conventional urban form based on the neighborhood theory; the other represents the new sustainable design. The ultimate aim is to define the obstacles hindering the full achievement of a sustainable urban form in this housing type. To undertake research investigations, a matrix of the design principles of sustainable urban forms has been initiated in order to facilitate the assessment of the urban forms of the two selected urban communities. Some qualitatively measurable design elements have been defined for each of these principles. The results of the analysis of the shift from ‘conventional’ to ‘sustainable’ case studies have revealed some aspects that would prevent the attainment of fully sustainable urban forms in newly designed social housing neighborhoods. Finally, the research concludes by recommending some fundamental actions to help meet these challenges in future design.

  6. Thermal Storage Systems Assessment for Energy Sustainability in Housing Units

    Directory of Open Access Journals (Sweden)

    Tania I. Lagunes Vega

    2016-04-01

    Full Text Available In order to achieve greater enhancements in energy sustainability for housing, the function and efficiency of two different passive cooling systems were studied: encapsulated water in recycled bottles of Polyethylene terephthalate (PET and polystyrene plates, in comparison with standard concrete slab systems, which are customarily used in housing. Experiments were placed over a tile surface, in which temperature changes were monitored for a period of 20 days from 08:00 to 20:00. The efficiency of passive thermal storage systems was endorsed through statistical analysis using the “SPSS” software. This resulted in a 17% energy saving, thus promoting energy sustainability in housing units, which reduces the use of electrical appliances required to stabilize conditions to achieve optimum thermal comfort for the human body inside a house, therefore, reducing electrical power consumption, CO2 emissions to the atmosphere and generating savings. Due to the complexity of a system with temperature changes, a fractal analysis was performed for each experimental system, using the “Benoit” software (V.1.3 with self-compatible tools of rescaled range (R/S and a wavelets method, showing that the thermal fluctuations on the tiles with the thermal storage system adapt to the rescaled range analysis and the regular tiles adapt to the wavelets method.

  7. Study of a thermoelectric system equipped with a maximum power point tracker for stand-alone electric generation.

    Science.gov (United States)

    Favarel, C.; Champier, D.; Bédécarrats, J. P.; Kousksou, T.; Strub, F.

    2012-06-01

    According to the International Energy Agency, 1.4 billion people are without electricity in the poorest countries and 2.5 billion people rely on biomass to meet their energy needs for cooking in developing countries. The use of cooking stoves equipped with small thermoelectric generator to provide electricity for basic needs (LED, cell phone and radio charging device) is probably a solution for houses far from the power grid. The cost of connecting every house with a landline is a lot higher than dropping thermoelectric generator in each house. Thermoelectric generators have very low efficiency but for isolated houses, they might become really competitive. Our laboratory works in collaboration with plane`te-bois (a non governmental organization) which has developed energy-efficient multifunction (cooking and hot water) stoves based on traditional stoves designs. A prototype of a thermoelectric generator (Bismuth Telluride) has been designed to convert a small part of the energy heating the sanitary water into electricity. This generator can produce up to 10 watts on an adapted load. Storing this energy in a battery is necessary as the cooking stove only works a few hours each day. As the working point of the stove varies a lot during the use it is also necessary to regulate the electrical power. An electric DC DC converter has been developed with a maximum power point tracker (MPPT) in order to have a good efficiency of the electronic part of the thermoelectric generator. The theoretical efficiency of the MMPT converter is discussed. First results obtained with a hot gas generator simulating the exhaust of the combustion chamber of a cooking stove are presented in the paper.

  8. Single anterior cervical discectomy and fusion (ACDF) using self- locking stand-alone polyetheretherketone (PEEK) cage: evaluation of pain and health-related quality of life.

    Science.gov (United States)

    Kapetanakis, Stylianos; Thomaidis, Tryfon; Charitoudis, George; Pavlidis, Pavlos; Theodosiadis, Panagiotis; Gkasdaris, Grigorios

    2017-09-01

    Anterior cervical discectomy and fusion (ACDF) constitutes the conventional treatment of cervical disc herniation due to degenerative disc disease (DDD). ACDF with plating presents a variety of complications postoperatively and stand-alone cages are thought to be a promising alternative. The aim of this study was firstly, to analyze prospectively collected data from a sample of patients treated with single ACDF using C-Plus self-locking stand-alone PEEK cage system, without the use of plates or screws, in order to evaluate pain levels of patients, utilizing Neck and Arm Pain scale as an expression of visual analogue scale (VAS). Secondly, we aimed to evaluate health-related quality of life, via the short-form 36 (SF-36) and Neck Disability Index (NDI). Thirty-six patients (19 male and 17 female) with mean age 49.6±7 years old who underwent successful single ACDF using self-locking stand-alone PEEK cage for symptomatic cervical DDD were selected for the study. Neck and Arm pain, as well as SF-36 and NDI were estimated preoperatively and 1, 3, 6, and 12 months postoperatively. Patients underwent preoperative and postoperative clinical, neurological and radiological evaluation. The clinical and radiological outcomes were satisfactory after a minimum 1-year follow-up. All results were statistically important (P<0.05), excluding improvement in NDI measured between 6 and 12 months. SF-36, Neck Pain, as well as Arm Pain featured gradual and constant improvement during follow-up, with best scores presenting at 12 months after surgery, while NDI reached its best at 6 months postoperatively. Generally, all scores showed improvement postoperatively during the different phases of the follow-up. Subsequently, ACDF using C-Plus cervical cage constitutes an effective method for cervical disc herniation treatment, in terms of postoperative improvement on pain levels and health-related quality of life and a safe alternative to the conventional method of treatment for cervical DDD.

  9. Segmental kyphosis after cervical interbody fusion with stand-alone polyetheretherketone (PEEK) cages: a comparative study on 2 different PEEK cages.

    Science.gov (United States)

    Kim, Chi Heon; Chung, Chun Kee; Jahng, Tae-Ahn; Park, Sung Bae; Sohn, Seil; Lee, Sungjoon

    2015-02-01

    Retrospective comparative study. Two polyetheretherketone (PEEK) cages of different designs were compared in terms of the postoperative segmental kyphosis after anterior cervical discectomy and fusion. Segmental kyphosis occasionally occurs after the use of a stand-alone cage for anterior cervical discectomy and fusion. Although PEEK material seems to have less risk of segmental kyphosis compared with other materials, the occurrence of segmental kyphosis for PEEK cages has been reported to be from 0% to 29%. There have been a few reports that addressed the issue of PEEK cage design. A total of 41 consecutive patients who underwent single-level anterior discectomy and fusion with a stand-alone cage were included. Either a round tube-type (Solis; 18 patients, S-group) or a trapezoidal tube-type (MC+; 23 patients, M-group) cage was used. The contact area between the cage and the vertebral body is larger in MC+ than in Solis, and anchoring pins were present in the Solis cage. The effect of the cage type on the segmental angle (SA) (lordosis vs. kyphosis) at postoperative month 24 was analyzed. Preoperatively, segmental lordosis was present in 12/18 S-group and 16/23 M-group patients (P=0.84). The SA was more lordotic than the preoperative angle in both groups just after surgery, with no difference between groups (P=0.39). At 24 months, segmental lordosis was observed in 9/18 S-group and 20/23 M-group patients (P=0.01). The patients in M-group were 7.83 times more likely than patients in S-group (P=0.04; odds ratio, 7.83; 95% confidence interval, 1.09-56.28) not to develop segmental kyphosis. The design of the PEEK cage used may influence the SA, and this association needs to be considered when using stand-alone PEEK cages.

  10. Clinician's perspectives of the relocation of a regional child and adolescent mental health service from co-located to stand alone premises.

    Science.gov (United States)

    Francis, K J; Boyd, C P; Sewell, J; Nurse, S

    2008-01-01

    Australia's National Mental Health Strategy's statement of rights and responsibilities states that children and adolescents admitted to a mental health facility or community program have the right to be separated from adult patients and provided with programs suited to their developmental needs. However, in rural Australia, where a lack of healthcare services, financial constraints, greater service delivery areas and fewer mental healthcare specialists represent the norm, Child and Adolescent Mental Health Services (CAMHS) are sometimes co-located with adult mental health services. The aim of the present study was to evaluate the impact of a recent relocation of a regional CAMHS in Victoria from co-located to stand alone premises. Six CAMHS clinicians who had experienced service delivery at a co-located setting and the current stand-alone CAMHS setting were interviewed about their perceptions of the impact of the relocation on service delivery. An exploratory interviewing methodology was utilized due to the lack of previous research in this area. Interview data were transcribed and analysed according to interpretative phenomenological analysis techniques. Findings indicated a perception that the relocation was positive for clients due to the family-friendly environment at the new setting and separation of CAMHS from adult psychiatric services. However, the impact of the relocation on clinicians was marked by a perceived loss of social capital from adult psychiatric service clinicians. These results provide increased understanding of the effects of service relocation and the influence of co-located versus stand-alone settings on mental health service delivery - an area where little prior research exists.

  11. Factors that can influence the economic feasibility of stand-alone and grid-connected photovoltaic systems: case studies using the software AVES-F

    International Nuclear Information System (INIS)

    Blasques, L.C.M.; Pinho, J.T.

    2004-01-01

    This paper presents case studies of economic feasibility of solar photovoltaic systems using the software AVES-F (Analysis of Economic Feasibility of Photovoltaic Systems), developed by the authors, considering cases of stand-alone and grid-connected systems. The software takes into account several factors that can influence the economic feasibility of these kind of systems, like load to be supplied, distance to the grid, the use regime of the system, applied subsidies and others. The main goal of this paper is to analyze some of these factors and to observe how they can affect the economics of PV systems for electricity generation. (authors)

  12. [Biomechanicsl evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass-ceramic on the human cervical spine].

    Science.gov (United States)

    Korinth, M C; Moersch, S; Ragoss, C; Schopphoff, E

    2003-12-01

    Recently, there has been a rapid increase in the use of cervical spine interbody fusion cages, differing in design and biomaterial used, in competition to autologous iliac bone graft and bone cement (PMMA). Limited biomechanical differences in primary stability, as well as advantages and disadvantages of each cage or material have been investigated in studies, using an in vitro human cervical spine model. 20 human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or PMMA after discectomy. Non-destructive biomechanical testing was performed, including flexion/extension and lateral bending using a spine testing apparatus. Three-dimensional segmental range of motion (ROM) was evaluated using an ultrasound measurement system. ROM increased more in flexion/extension and lateral bending after PMMA fusion (26.5%/36.1%), then after implantation of the Ecopore-cage (8.1%/7.8%). In this first biomechanical in vitro examination of a new porous ceramic bone replacement material a) the feasibility and reproducibility of biomechanical cadaveric cervical examination and its applicability was demonstrated, b) the stability of the ceramic cage as a stand alone interbody cage was confirmed in vitro, and c) basic information and knowledge for our intended biomechanical and histological in vivo testing, after implantation of Ecopore in cervical sheep spines, were obtained.

  13. Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels.

    Science.gov (United States)

    Kao, Ting-Hsien; Wu, Chen-Hao; Chou, Yu-Ching; Chen, Hsien-Te; Chen, Wen-Hsien; Tsou, Hsi-Kai

    2014-10-01

    To determine risk factors for subsidence in patients treated with anterior cervical discectomy and fusion (ACDF) and stand-alone polyetheretherketone (PEEK) cages. Records of patients with degenerative spondylosis or traumatic disc herniation resulting in radiculopathy or myelopathy between C2 and C7 who underwent ACDF with stand-alone PEEK cages were retrospectively reviewed. Cages were filled with autogenous cancellous bone harvested from iliac crest or hydroxyapatite. Subsidence was defined as a decrease of 3 mm or more of anterior or posterior disc height from that measured on the postoperative radiograph. Eighty-two patients (32 males, 50 females; 182 treatment levels) were included in the analysis. Most patients had 1-2 treatment levels (62.2 %), and 37.8 % had 3-4 treatment levels. Treatment levels were from C2-7. Of the 82 patients, cage subsidence occurred in 31 patients, and at 39 treatment levels. Multivariable analysis showed that subsidence was more likely to occur in patients with more than two treatment levels, and more likely to occur at treatment levels C5-7 than at levels C2-5. Subsidence was not associated with postoperative alignment change but associated with more disc height change (relatively oversized cage). Subsidence is associated with a greater number of treatment levels, treatment at C5-7 and relatively oversized cage use.

  14. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O. [University Medical Centre Mannheim, Medical Faculty Mannheim-University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Reich, C.; Kaiser, W.A. [Friedrich-Schiller-University Hospital Jena, Institute of Diagnostic and Interventional Radiology I, Jena (Germany); Dietzel, M. [Friedrich-Alexander-University Hospital Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Baltzer, P.A.T. [Medical University Vienna, Institute of Radiology and Nuclear Medicine, Vienna (Austria)

    2015-06-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  15. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    International Nuclear Information System (INIS)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O.; Reich, C.; Kaiser, W.A.; Dietzel, M.; Baltzer, P.A.T.

    2015-01-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  16. Planning tool for least cost system design based on the operating experience of fifty stand-alone photovoltaic hybrid systems

    Energy Technology Data Exchange (ETDEWEB)

    Bopp, G.; Neufeld, R.; Preiser, K.; Puls, H.-G.; Sauer, D.U.; Senft, S.; Schulz, M. [Fraunhofer Inst. for Solar Energy Systems ISE, Freiburg (Germany)

    2001-07-01

    The Fraunhofer Institute for Solar Energy (ISE) conducted a project involving the design and installation of grid-independent photovoltaic systems with battery storage to 30 remote lodges, mountain huts, farms and private houses. More than half the participating dwellings belonged to the German Alpine Club and are used only for summer months. The photovoltaic systems ranged from lighting for unattended huts and larger systems for lodges with permanent staff and an electricity demand in the order of 0.1 to 40 kWh per day. The objective of the project was to determine the amount of maintenance work that is required to keep the systems working reliably. The Institute prepared inspection manuals and carried out some sample inspections. Other inspections were carried out by the independent operator. With the information entered into the inspection manuals, Fraunhofer ISE analyzed the causes of faults and prepared statistics on interruptions to operations. The average probability of breakdowns could then be determined along with the requirements for optimizing individual components and the entire system. Besides the solar generator, most components of a photovoltaic system with battery storage require repairs, post-installation improvements, regular maintenance or replacement of batteries at intervals of 5 to 10 years. At the end of two years of regular maintenance, the fault rates were reduced from 3 to 1. The Institute also developed the Technical and Least Cost Optimisation (TALCO) tool to calculate the lifetime costs of remote area power supply systems. TALCO describes the electrical characteristics of various components under operating conditions. All economic factors linked to the components are considered. The optimisation algorithm presents the minimum lifetime costs for a given energy demand at specific locations under given boundary conditions. Analytical results showed that PV-hybrid systems are the most cost effective solution for most system applications

  17. Shelter from the Storm: Roles, responsibilities, and challenges in United States housing policy governance.

    Science.gov (United States)

    Willison, Charley

    2017-11-01

    Housing is a critical social determinant of health. Housing policy not only affects health by improving housing quality, affordability, and insecurity; housing policy affects health upstream through the politics that shape housing policy design, implementation, and management. These politics, or governance strategies, determine the successes or failures of housing policy programs. This paper is an overview of challenges in housing policy governance in the United States. I examine the important relationship between housing and health, and emphasize why studying housing policy governance matters. I then present three cases of housing governance challenges in the United States, from each pathway by which housing affects health - housing quality, affordability, and insecurity. Each case corresponds to an arm of the TAPIC framework for evaluating governance (Krieger and Higgins) [1], to assess mechanisms of housing governance in each case. While housing governance has come a long way over the past century, political decentralization and the expansion of the submerged state have increased the number of political actors and policy conflict in many areas. This creates inherent challenges for improving accountability, transparency, and policy capacity. In many instances, too, reduced government accountability and transparency increases the risk of harm to the public and lessens governmental integrity. Copyright © 2017 The Author. Published by Elsevier B.V. All rights reserved.

  18. In-core monitor housing replacement at Fukushima Daiichi Unit No.4

    International Nuclear Information System (INIS)

    Arai, Tomoyuki

    1999-01-01

    The in-core monitor (ICM) housing replacement of a Boiling Water Reactor (BWR) has been completed at Fukushima-Daiichi Unit No. 4 (1F4) of the Tokyo Electric Power Company (TEPCO) in Japan. Since cracking of the inside surface of an ICM housing was found in this unit, the ICM housing was replaced with one made of low-carbon stainless steel (SS) to improve Intergranular Stress Corrosion Cracking (IGSCC) resistance. This project is the first application of the replacement procedure for the ICM housing and employs various advanced technologies. The outline of the ICM housing replacement project and applied technologies are discussed in this paper. (author)

  19. Effect of State Feedback Coupling and System Delays on the Transient Performance of Stand-Alone VSI with LC Output Filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    The influence of state feedback coupling in the dynamics performance of power converters for stand-alone microgrids is investigated. Computation and PWM delays are the main factors that limit the achievable bandwidth of current regulators in digital implementations. In particular, the performance...... of state feedback decoupling is degraded because of these delays. Two decoupling techniques to improve the transient response of the system are investigated, named non-ideal and ideal capacitor voltage decoupling respectively. In particular, the latter solution consists in leading the capacitor voltage...... on the state feedback decoupling path in order to compensate for system delays. Practical implementation issues are discussed with reference to both the decoupling techniques. A design methodology for the voltage loop, that considers the closed loop transfer functions developed for the inner loop, is also...

  20. Synchronized Pulsed dc - dc Converter as Maximum Power Position Tracker with Wide Load and Insolation Variation for Stand Alone PV System

    International Nuclear Information System (INIS)

    Hardik, P. Desai; Ranjan Maheshwari

    2011-01-01

    This paper investigates the interest focused on employing parallel connected dc-dc converter with high tracking effectiveness under wide variation in environmental conditions (Insolation) and wide load variation. dc-dc converter is an essential part of the stand alone PV system. Paper also presents an approach on how duty cycle for maximum power position (MPP) is adjusted by taking care of varying load conditions and without iterative steps. Synchronized PWM pulses are employed for the converter. High tracking efficiency is achieved with continuous input and inductor current. In this approach, the converter can he utilized in buck as well in boost mode. The PV system simulation was verified and experimental results were in agreement to the presented scheme. (authors)

  1. Effects of ozone as a stand-alone and coagulation-aid treatment on the reduction of trihalomethanes precursors from high DOC and hardness water.

    Science.gov (United States)

    Sadrnourmohamadi, Mehrnaz; Gorczyca, Beata

    2015-04-15

    This study investigates the effect of ozone as a stand-alone and coagulation aid on the removal of dissolved organic carbon (DOC) from the water with a high level of DOC (13.8 mgL(-1)) and calcium hardness (270 mgL(-1)) CaCO3. Natural water collected from the Assiniboine River (Manitoba, Canada) was used in this study. Effectiveness of ozone treatment was evaluated by measurement of DOC, DOC fractions, UV254, and trihalomethane formation potential (THMFP). Additionally, zeta potential and dissolved calcium concentration were measured to discern the mechanism of ozone reactions. Results indicated that 0.8 mg O3/mg DOC ozone stand-alone can cause up to 86% UV254 reduction and up to 27% DOC reduction. DOC fractionation results showed that ozone can change the composition of DOC in the water samples, converting the hydrophobic fractions into hydrophilic ones and resulting in the reduction of THMFP. Also, ozone caused a decrease in particle stability and dissolved calcium concentration. These simultaneous ozonation effects caused improved water flocculation and enhanced removal of DOC. This resulted in reduction of the coagulant dosage when ozone doses higher than 0.2 mg O3/mg DOC were applied prior to coagulation with ferric sulfate. Also, pre-ozonation-coagulation process achieved preferential THMFP removal for all of the ozone doses tested (0-0.8 mg O3/mg DOC), leading to a lower specific THMFP in pre-ozonated-coagulated waters than in the corresponding ozonated waters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Comparison of plate-cage construct and stand-alone anchored spacer in the surgical treatment of three-level cervical spondylotic myelopathy: a preliminary clinical study.

    Science.gov (United States)

    Shi, Sheng; Liu, Zu-De; Li, Xin-Feng; Qian, Lie; Zhong, Gui-Bin; Chen, Fang-Jing

    2015-09-01

    Although stand-alone cages were advocated to be superior to plate-cage construct (PCC) because of comparable clinical outcomes and fewer plate-related complications, cage dislocation and subsidence were frequently mentioned in multilevel fusion. There are some concerns about whether these issues can be effectively prevented in multilevel anterior cervical discectomy and fusion (ACDF) by stand-alone anchored spacer (SAAS). The aim was to compare clinical outcomes, radiologic parameters, and complications of PCC and SAAS in the treatment of three-level cervical spondylotic myelopathy (CSM). This was a retrospective comparative study. A total of 38 consecutive patients with three-level CSM (ACDF with PCC, 20 patients; ACDF with SAAS, 18 patients) were reviewed. Clinical outcomes were assessed using Japanese Orthopaedic Association and Neck Disability Index. The radiologic evaluations included cervical alignment (CA), segmental angle (SA), postoperative curvature loss (PCL), and incidence of subsidence. All the aforementioned parameters were compared before and after surgery between two groups. Besides, the aforementioned results were also compared between the two groups. The complications were also recorded. The mean follow-up period was 30.3 months. No significant differences were observed in clinical outcomes between the two groups (p>.05). Additionally, no significant differences existed in fusion rate between the two groups. There were significant differences in PCL of SA and CA and correction of SA between the two groups (pSAAS group, and the potential of SAAS to reduce the incidence of postoperative dysphagia was not proven. No other complications were observed in this study. In the surgical treatment of three-level CSM, PCC is superior to SAAS in correction and maintenance of SA and avoiding cage subsidence, although the technique of ACDF with SAAS yielded encouraging clinical outcomes and high fusion rate. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. PR2ALIGN: a stand-alone software program and a web-server for protein sequence alignment using weighted biochemical properties of amino acids.

    Science.gov (United States)

    Kuznetsov, Igor B; McDuffie, Michael

    2015-05-07

    Alignment of amino acid sequences is the main sequence comparison method used in computational molecular biology. The selection of the amino acid substitution matrix best suitable for a given alignment problem is one of the most important decisions the user has to make. In a conventional amino acid substitution matrix all elements are fixed and their values cannot be easily adjusted. Moreover, most existing amino acid substitution matrices account for the average (dis)similarities between amino acid types and do not distinguish the contribution of a specific biochemical property to these (dis)similarities. PR2ALIGN is a stand-alone software program and a web-server that provide the functionality for implementing flexible user-specified alignment scoring functions and aligning pairs of amino acid sequences based on the comparison of the profiles of biochemical properties of these sequences. Unlike the conventional sequence alignment methods that use 20x20 fixed amino acid substitution matrices, PR2ALIGN uses a set of weighted biochemical properties of amino acids to measure the distance between pairs of aligned residues and to find an optimal minimal distance global alignment. The user can provide any number of amino acid properties and specify a weight for each property. The higher the weight for a given property, the more this property affects the final alignment. We show that in many cases the approach implemented in PR2ALIGN produces better quality pair-wise alignments than the conventional matrix-based approach. PR2ALIGN will be helpful for researchers who wish to align amino acid sequences by using flexible user-specified alignment scoring functions based on the biochemical properties of amino acids instead of the amino acid substitution matrix. To the best of the authors' knowledge, there are no existing stand-alone software programs or web-servers analogous to PR2ALIGN. The software is freely available from http://pr2align.rit.albany.edu.

  4. Real-Time Detection of Tsunami Ionospheric Disturbances with a Stand-Alone GNSS Receiver: A Preliminary Feasibility Demonstration

    Science.gov (United States)

    Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Mazzoni, Augusto; Crespi, Mattia; Wei, Yong; Mannucci, Anthony J.

    2017-04-01

    It is well known that tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances can be studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and estimate slant TEC (sTEC) variations in a real-time scenario. Using the VARION algorithm we compute TEC variations at 56 GPS receivers in Hawaii as induced by the 2012 Haida Gwaii tsunami event. We observe TEC perturbations with amplitudes of up to 0.25 TEC units and traveling ionospheric perturbations (TIDs) moving away from the earthquake epicenter at an approximate speed of 316 m/s. We perform a wavelet analysis to analyze localized variations of power in the TEC time series and we find perturbation periods consistent with a tsunami typical deep ocean period. Finally, we present comparisons with the real-time tsunami MOST (Method of Splitting Tsunami) model produced by the NOAA Center for Tsunami Research and we observe variations in TEC that correlate in time and space with the tsunami waves.

  5. Enabling Housing Cooperatives: policy lessons from Sweden, India and the United States.

    Science.gov (United States)

    Ganapati, Sukumar

    2010-01-01

    Housing cooperatives became active in urban areas in Sweden, India and the United States during the interwar period. Yet, after the second world war, while housing cooperatives grew phenomenally nationwide in Sweden and India, they did not do so in the United States. This article makes a comparative institutional analysis of the evolution of housing cooperatives in these three countries. The analysis reveals that housing cooperatives' relationship with the state and the consequent support structures explain the divergent evolution. Although the relationships between cooperatives and the state evolved over time, they can be characterized as embedded autonomy, overembeddedness and disembeddedness in Sweden, India and the United States respectively. Whereas the consequent support structures for housing cooperatives became well developed in Sweden and India, such structures have been weak in the United States. The article highlights the need for embedded autonomy and the need for supportive structures to enable the growth of housing cooperatives.

  6. Fiscal 2000 regional new energy vision formulation - Financially aided project. Report on regional new energy vision formulation for Ueno village (Object of survey: Commercialization feasibility study for a stand-alone type wind power generation system at Ueno German Culture Village); 2000 nendo Uenoson chiiki shin energy vision sakutei hokokusho. Ueno Doitsu bunkamura dokuritsugata furyoku hatsuden system jigyoka feasibility study chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A survey is conducted about the profitability of installing a stand-alone type wind power system at Ueno village (Miyako Island), Okinawa Prefecture. The German Culture Village, which is an integrated resort house provided with accommodations (500 people), educational and cultural facilities, and sports facilities consumes 272 MWh/year in electric power. The results of the survey are summarized in six chapters, which are (1) the survey of the business under the project to be the object of feasibility study, (2) project to be the object of feasibility study, (3) outline of the Okinawa Electric Power Co., Inc., Miyakojima system and problems to ensue from its interconnection with wind turbines, (4) survey of stand-alone type wind turbine power generation systems, (5) technical/economic feasibility study, and (6) project management and future tasks. It is concluded that there will be profit in the presence of a subsidy that covers 65% or more of the total cost of constructing a system comprising three 600 KW wind turbines, three 400 kW class diesel generators, and storage batteries. (NEDO)

  7. DOE Zero Energy Ready Home Case Study: United Way of Long Island, United Veterans Beacon House

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2017-09-01

    United Way of Long Island’s Housing Development Corporation built this 3,719-ft2 two–story, 5-bedroom home in Huntington Station, New York, to the rigorous performance requirements of the U.S. Department of Energy’s Zero Energy Ready Home Program. The home is packed with high-performance features like LED lighting and ENERGY STAR appliances. The asymmetrical, optimally angled roof provides plenty of space for roof-mounted solar panels for electric generation and hot water.

  8. Design of laboratory and animal housing unit for radionuclide studies

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The design of a combined analytical laboratory and animal housing facility is discussed. By having sample processing facilities in close proximity to the experimental animals, the necessity for transporting biological specimens long distances has been curtailed. In addition, complete radionuclide counting equipment has been installed so that samples need not leave the animal housing site for analysis, a feature based on radiological health requirements. (U.S.)

  9. A practical multi-objective design approach for optimum exhaust heat recovery from hybrid stand-alone PV-diesel power systems

    International Nuclear Information System (INIS)

    Yousefi, Moslem; Kim, Joong Hoon; Hooshyar, Danial; Yousefi, Milad; Sahari, Khairul Salleh Mohamed; Ahmad, Rodina Binti

    2017-01-01

    Highlights: • Heat recovery exchanger is designed based on practical conditions of a hybrid power system. • Off-the-grid electricity system modeling and analysis using micro-grid analysis software HOMER. • NSGA-II is used for the multi-objective design optimization task. • A new local search is proposed to incorporate the engineering knowledge in NSGA-II. • The proposed approach outperforms the existing ones. - Abstract: Integration of solar power and diesel generators (DGs) together with battery storage has proven to be an efficient choice for stand-alone power systems (SAPS). For higher energy efficiency, heat recovery from exhaust gas of the DG can also be employed to supply all or a portion of the thermal energy demand. Although the design of such heat recovery systems (HRSs) has been studied, the effect of solar power integration has not been taken into account. In this paper, a new approach for practical design of these systems based on varying engine loads is presented. Fast and elitist non-dominated sorting genetic algorithm (NSGA-II) equipped with a novel local search was used for the design process, considering conflicting objectives of annual energy recovery and total cost of the system, and six design variables. An integrated power system, designed for a remote SAPS, was used to evaluate the design approach. The optimum power supply system was first designed using the commercial software Hybrid Optimization of Multiple Energy Resources (HOMER), based on power demand and global solar energy in the region. Heat recovery design was based on the outcome of HOMER for DG hourly load, considering different power scenarios. The proposed approach improves the annual heat recovery of the PV/DG/battery system by 4%, PV/battery by 1.7%, and stand-alone DG by 1.8% when compared with a conventional design based on nominal DG load. The results prove that the proposed approach is effective and that load calculations should be taken into account prior to

  10. The Research on Second-Order ADRC Algorithm of Using Wind Turbine Virtual Inertia to Participate in Primary Frequency Regulation in a Small Stand-Alone Microgrid

    Directory of Open Access Journals (Sweden)

    Wang Yi

    2018-01-01

    Full Text Available In order to improve the transient stability of frequency in a small stand-alone microgrid (SSM, this paper takes a SSM composed of a direct-drive permanent magnet synchronous generator (D-PMSG and a micro gas turbine (MGT as the background and uses wind turbine generator (WTG virtual inertia (VI to participate in the primary (short-term system frequency regulation. First of all, this paper constructs a grid-connected model composed of a WTG and a MGT, analyzes the WTG virtual inertia frequency regulation mechanism, and explains the principle of proportional-differentiation (PD virtual inertia control (VIC and its shortcomings. Secondly, the paper introduces the structure principle of n-order active disturbance rejection control (ADRC and deduces the design process of second-order ADRC-VIC. Finally, through the simulation and experimental verification, comparing the frequency perturbation of without-VIC, PD-VIC, and ADRC-VIC, it is concluded that PD-VIC and ADRC-VIC both can use the WTG virtual inertia to participate in the primary frequency regulation. The frequency regulation effect of ADRC-VIC is better than PD-VIC, ADRC-VIC can extend the rotor speed recovery time and avoid overshoot, and its frequency fluctuation amplitude and settling time are obviously improved, and ADRC-VIC can effectively avoid the overshoot phenomenon of the MGT output power.

  11. Optimal Sizing of a Stand-Alone Hybrid Power System Based on Battery/Hydrogen with an Improved Ant Colony Optimization

    Directory of Open Access Journals (Sweden)

    Weiqiang Dong

    2016-09-01

    Full Text Available A distributed power system with renewable energy sources is very popular in recent years due to the rapid depletion of conventional sources of energy. Reasonable sizing for such power systems could improve the power supply reliability and reduce the annual system cost. The goal of this work is to optimize the size of a stand-alone hybrid photovoltaic (PV/wind turbine (WT/battery (B/hydrogen system (a hybrid system based on battery and hydrogen (HS-BH for reliable and economic supply. Two objectives that take the minimum annual system cost and maximum system reliability described as the loss of power supply probability (LPSP have been addressed for sizing HS-BH from a more comprehensive perspective, considering the basic demand of load, the profit from hydrogen, which is produced by HS-BH, and an effective energy storage strategy. An improved ant colony optimization (ACO algorithm has been presented to solve the sizing problem of HS-BH. Finally, a simulation experiment has been done to demonstrate the developed results, in which some comparisons have been done to emphasize the advantage of HS-BH with the aid of data from an island of Zhejiang, China.

  12. Stand-Alone Containment Analysis of the Phébus FPT Tests with the ASTEC and the MELCOR Codes: The FPT-0 Test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2017-01-01

    Full Text Available The integral Phébus tests were probably one of the most important experimental campaigns performed to investigate the progression of severe accidents in light water reactors. In these tests, the degradation of a PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the results of such tests, numerical codes such as ASTEC and MELCOR have been developed to describe the evolution of a severe accident. After the termination of the experimental Phébus campaign, these two codes were furthermore expanded. Therefore, the aim of the present work is to reanalyze the first Phébus test (FPT-0 employing the updated ASTEC and MELCOR versions to ensure that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The analysis focuses on the stand-alone containment aspects of this test, and the paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products behavior. This paper is part of a series of publications covering the four executed Phébus tests employing a solid PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3.

  13. Development of Stand Alone Application Tool for Processing and Quality Measurement of Weld Imperfection Image Captured by μ-Focused Digital Radiography Using MATLAB- Based Graphical User Interface

    Directory of Open Access Journals (Sweden)

    PZ Nadila

    2012-12-01

    Full Text Available Digital radiography incresingly is being applied in the fabrication industry. Compared to film- based radiography, digitally radiographed images can be acquired with less time and fewer exposures. However, noises can simply occur on the digital image resulting in a low-quality result. Due to this and the system’s complexity, parameters’ sensitivity, and environmental effects, the results can be difficult to interpret, even for a radiographer. Therefore, the need of an application tool to improve and evaluate the image is becoming urgent. In this research, a user-friendly tool for image processing and image quality measurement was developed. The resulting tool contains important components needed by radiograph inspectors in analyzing defects and recording the results. This tool was written by using image processing and the graphical user interface development environment and compiler (GUIDE toolbox available in Matrix Laboratory (MATLAB R2008a. In image processing methods, contrast adjustment, and noise removal, edge detection was applied. In image quality measurement methods, mean square error (MSE, peak signal-to-noise ratio (PSNR, modulation transfer function (MTF, normalized signal-to-noise ratio (SNRnorm, sensitivity and unsharpness were used to measure the image quality. The graphical user interface (GUI wass then compiled to build a Windows, stand-alone application that enables this tool to be executed independently without the installation of MATLAB.

  14. Methodology for predicting sequences of mean monthly clearness index and daily solar radiation data in remote areas: Application for sizing a stand-alone PV system

    Energy Technology Data Exchange (ETDEWEB)

    Mellit, A. [Department of Electronics, Institute of Sciences Engineering, Centre University of Medea, Medea 26000 (Algeria); Department of Electronics, Faculty of Science Engineering, Blida University, Blida 09000 (Algeria); Kalogirou, S.A. [Higher Technical Institute, P.O. Box 20423, Nicosia 2152 (Cyprus); Shaari, S. [Faculty of Applied Sciences, Universiti Teknologi MARA 40450 Shah Alam, Selangor (Malaysia); Salhi, H. [Department of Electronics, Faculty of Science Engineering, Blida University, Blida 09000 (Algeria); Hadj Arab, A. [Development Centre of Renewable Energy (CDER), P.O. Box 62, Bouzareah, Algiers 16000 (Algeria); Departamento de Energias Renerables, CIEMAT, Arda Complutense, 22, Madrid 28040 (Spain)

    2008-07-15

    In this paper, a suitable adaptive neuro-fuzzy inference system (ANFIS) model is presented for estimating sequences of mean monthly clearness index (anti K{sub t}) and total solar radiation data in isolated sites based on geographical coordinates. The magnitude of solar radiation is the most important parameter for sizing photovoltaic (PV) systems. The ANFIS model is trained by using a multi-layer perceptron (MLP) based on fuzzy logic (FL) rules. The inputs of the ANFIS are the latitude, longitude, and altitude, while the outputs are the 12-values of mean monthly clearness index anti K{sub t}. These data have been collected from 60 locations in Algeria. The results show that the performance of the proposed approach in the prediction of mean monthly clearness index anti K{sub t} is favorably compared to the measured values. The root mean square error (RMSE) between measured and estimated values varies between 0.0215 and 0.0235 and the mean absolute percentage error (MAPE) is less than 2.2%. In addition, a comparison between the results obtained by the ANFIS model and artificial neural network (ANN) models, is presented in order to show the advantage of the proposed method. An example for sizing a stand-alone PV system is also presented. This technique has been applied to Algerian locations, but it can be generalized for any geographical position. It can also be used for estimating other meteorological parameters such as temperature, humidity and wind speed. (author)

  15. A Study on Electric Power Smoothing System for Lead-Acid Battery of Stand-Alone Natural Energy Power System Using EDLC

    Science.gov (United States)

    Jia, Yan; Shibata, Ryosuke; Yamamura, Naoki; Ishida, Muneaki

    To resolve energy shortage and global warming problem, renewable natural resource and its power system has been gradually generalizing. However, the power fluctuation suppressing in short period and the balance control of consumption and supply in long period are two of main problems that need to be resolved urgently in natural energy power system. In Stand-alone Natural Energy Power System (SNEPS) with power energy storage devices, power fluctuation in short period is one of the main reasons that recharge cycle times increase and lead-acid battery early failure. Hence, to prolong the service life of lead-acid battery and improve power quality through suppressing the power fluctuation, we proposed a method of electric power smoothing for lead-acid battery of SNEPS using bi-directional Buck/Boost converter and Electric Double Layer Capacitor (EDLC) in this paper. According to the test data of existing SNEPS, a power fluctuation condition is selected and as an example to analyze the validity of the proposed method. The analysis of frequency characteristics indicates the power fluctuation is suppressed a desired range in the target frequency region. The experimental results of confirmed the feasibility of the proposed system and the results well satisfy the requirement of system design.

  16. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Science.gov (United States)

    Daudin, L.; Barberet, Ph.; Serani, L.; Moretto, Ph.

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d'Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA's nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  17. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    Energy Technology Data Exchange (ETDEWEB)

    Daudin, L., E-mail: daudin@cenbg.in2p3.fr [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Barberet, Ph.; Serani, L.; Moretto, Ph. [Université Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA’s nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  18. Direct Flux Control for Stand-Alone Operation Brushless Doubly Fed Induction Generators Using a Resonant-Based Sliding-Mode Control Approach

    Directory of Open Access Journals (Sweden)

    Kai Ji

    2018-04-01

    Full Text Available In this paper, a novel voltage control strategy for stand-alone operation brushless doubly fed induction generators for variable speed constant frequency wind energy conversion systems was presented and discussed. Based on the model of the power generation system, the proposed direct flux control strategy employs a nonlinear reduced-order generalized integrator-based resonant sliding-mode control approach to directly calculate and regulate the output value of converter which the control winding stator requires so as to eliminate its instantaneous errors, without involving any synchronous rotating coordinate transformations. The stability, robustness and convergence capability of the proposed control strategy were described and analyzed. Owing to the fact no additional current control inner loops are involved, the system configuration is therefore simplified and the dynamic performance enhanced. A constant converter switching frequency was achieved by using space vector pulse width modulation, which reduces the harmonics of the generator terminal voltage. In addition, the feasibility and validity of the proposed scheme is verified by experiments, and excellent steady and transient performance is achieved.

  19. Projecting housing starts and softwood lumber consumption in the United States

    Science.gov (United States)

    Jeffrey P. Prestemon; David N. Wear; Karen L. Abt; Robert C. Abt

    2018-01-01

    New residential construction is a primary user of wood products in the United States; therefore, wood products projections require understanding the determinants of housing starts. We model quarterly US total, single-family, and multifamily housing starts with several model specifications, using data from 1979 to 2008, and evaluate their...

  20. Continental United States Military Housing Inspection National Capital Region

    Science.gov (United States)

    2015-08-13

    mechanical rooms, electrical rooms, laundry rooms, lounges, and common kitchen areas. We interviewed residents, maintenance personnel, housing...standards, the National Electrical Code (NEC), U.S. Environmental Protection Agency (EPA) standards, and international building codes. Findings We found...that could affect the health, safety, and well-being of warfighters and their families: 168 electrical system, 131 fire protection system, and 17

  1. 44 CFR 206.118 - Disposal of housing units.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY DISASTER ASSISTANCE FEDERAL DISASTER ASSISTANCE Federal Assistance to..., has a site that complies with local codes and ordinances and part 9 of this Title. (ii) Adjustment to... providing temporary housing to disaster victims in major disasters and emergencies. As a condition of the...

  2. The international phase 4 validation study of the EORTC QLQ-SWB32: A stand-alone measure of spiritual well-being for people receiving palliative care for cancer

    NARCIS (Netherlands)

    Vivat, B.; Young, T. E.; Winstanley, J.; Arraras, J. I.; Black, K.; Boyle, F.; Bredart, A.; Costantini, A.; Guo, J.; Irarrazaval, M. E.; Kobayashi, K.; Kruizinga, R.; Navarro, M.; Omidvari, S.; Rohde, G. E.; Serpentini, S.; Spry, N.; van Laarhoven, H. W. M.; Yang, G. M.

    2017-01-01

    The EORTC Quality of Life Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual well-being (SWB) for palliative cancer patients. Participants (n = 451)-from 14 countries on four continents; 54% female; 188

  3. The Impact of Course Delivery Systems on Student Achievement and Sense of Community: A Comparison of Learning Community versus Stand-Alone Classroom Settings in an Open-Enrollment Inner City Public Community College

    Science.gov (United States)

    Bandyopadhyay, Pamela

    2010-01-01

    This study examined the effects of two types of course delivery systems (learning community classroom environments versus stand-alone classroom environments) on the achievement of students who were simultaneously enrolled in remedial and college-level social science courses at an inner city open-enrollment public community college. This study was…

  4. This is my neighborhood: comparing United States and Australian Oxford House Neighborhoods.

    Science.gov (United States)

    Ferrari, Joseph R; Jason, Leonard A; Blake, Ron; Davis, Margaret I; Olson, Bradley D

    2006-01-01

    The number of Oxford Houses, communal-living, mutual help settings for persons in recovery of alcohol and substance abuse, has spread across the United States and recently in and around Melbourne, Australia. In this study 55 US and 6 AU Houses were compared descriptively for their neighborhood characteristics. Across settings, there were greater similarities than significant differences in the locations. Results imply that Australian Oxford Houses are "safe and sober" settings for persons in recovery consistent with the original United States model in physical dwelling settings.

  5. LESS SPACE, MORE SPATIALITY FOR LOW-INCOME HOUSING UNITS IN EGYPT: IDEAS FROM JAPAN

    Directory of Open Access Journals (Sweden)

    Nermine Abdel Gelil

    2011-07-01

    Full Text Available In 1996, the Egyptian government launched a national housing project for low-income families. To minimize cost, it has progressively reduced units’ sizes. Numerous surveys indicate that unit specifications were based on political and economic criteria, rather than on users’ needs, which resulted in the recurrence of the persistent phenomenon of individual modifications. A number of scholars and architects concerned with this phenomenon are advocating the revival of the social design principles of traditional Cairene houses (16th –19th century after adapting them to contemporary needs. However, they provide no concrete solutions as to how to achieve this in small-scale units located in multi-storey buildings. During my research in Japan, I was introduced to traditional middle class urban houses. Their practical designs used to resolve issues of privacy, internal flexibility, storage, and family growth can be beneficially applied to housing units in Egypt. This paper first explains why relying solely on traditional housing designs to resolve social issues associated with low-income units in Egypt is both fanciful and incomplete, then discusses why ideas from Japanese homes can be beneficially applied to low-income housing units in Egypt. Third, this paper examines issues in these units and the resultant modifications by Egyptian households. Next, it analyzes concepts of spatial organization, modular systems, partitioning, and storage in traditional middle class urban houses in Japan. Finally, this paper formulates proposals for fulfilling the social needs of occupants in Egypt by integrating these ideas into low-income housing units.

  6. CANGS DB: a stand-alone web-based database tool for processing, managing and analyzing 454 data in biodiversity studies

    Directory of Open Access Journals (Sweden)

    Schlötterer Christian

    2011-06-01

    Full Text Available Abstract Background Next generation sequencing (NGS is widely used in metagenomic and transcriptomic analyses in biodiversity. The ease of data generation provided by NGS platforms has allowed researchers to perform these analyses on their particular study systems. In particular the 454 platform has become the preferred choice for PCR amplicon based biodiversity surveys because it generates the longest sequence reads. Nevertheless, the handling and organization of massive amounts of sequencing data poses a major problem for the research community, particularly when multiple researchers are involved in data acquisition and analysis. An integrated and user-friendly tool, which performs quality control, read trimming, PCR primer removal, and data organization is desperately needed, therefore, to make data interpretation fast and manageable. Findings We developed CANGS DB (Cleaning and Analyzing Next Generation Sequences DataBase a flexible, stand alone and user-friendly integrated database tool. CANGS DB is specifically designed to organize and manage the massive amount of sequencing data arising from various NGS projects. CANGS DB also provides an intuitive user interface for sequence trimming and quality control, taxonomy analysis and rarefaction analysis. Our database tool can be easily adapted to handle multiple sequencing projects in parallel with different sample information, amplicon sizes, primer sequences, and quality thresholds, which makes this software especially useful for non-bioinformaticians. Furthermore, CANGS DB is especially suited for projects where multiple users need to access the data. CANGS DB is available at http://code.google.com/p/cangsdb/. Conclusion CANGS DB provides a simple and user-friendly solution to process, store and analyze 454 sequencing data. Being a local database that is accessible through a user-friendly interface, CANGS DB provides the perfect tool for collaborative amplicon based biodiversity surveys

  7. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  8. Effects of a stand-alone web-based electronic screening and brief intervention targeting alcohol use in university students of legal drinking age: A randomized controlled trial.

    Science.gov (United States)

    Ganz, Thomas; Braun, Michael; Laging, Marion; Schermelleh-Engel, Karin; Michalak, Johannes; Heidenreich, Thomas

    2018-02-01

    Many intervention efforts targeting student drinking were developed to address US college students, which usually involves underage drinking. It remains unclear, if research evidence from these interventions is generalizable to university and college students of legal drinking age, e.g., in Europe. To evaluate the effectiveness of a translated and adapted version of the eCHECKUP TO GO, applied as stand-alone web-based electronic screening and brief intervention (e-SBI), in German university students at risk for hazardous drinking. A fully automated web-based two-arm parallel-group randomized controlled trial was conducted. Participants were randomized to an e-SBI or assessment-only (AO) condition. The current paper analyzed students with baseline AUDIT-C scores ≥3 for women and ≥4 for men (sample at baseline: e-SBI [n=514], AO [n=467]; 3-month follow-up: e-SBI [n=194], AO [n=231]; 6-month follow-up: e-SBI [n=146], AO [n=200]). The primary outcome was prior four weeks' alcohol consumption. Secondary outcomes were frequency of heavy drinking occasions, peak blood alcohol concentration, and number of alcohol-related problems. Mixed linear model analyses revealed significant interaction effects between groups and time points on the primary outcome after 3 and 6months. Compared to students in the AO condition, students in the e-SBI condition reported consuming 4.11 fewer standard drinks during the previous four weeks after 3months, and 4.78 fewer standard drinks after 6months. Mixed results were found on secondary outcomes. The results indicate that evidence on and knowledge of web-based e-SBIs based on US college student samples is transferable to German university students of legal drinking age. However, knowledge of what motivates students to complete programs under voluntary conditions, although rare, is needed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Regional characteristics of individual housing units in Serbia from the aspect of applied building technologies

    Directory of Open Access Journals (Sweden)

    Jovanović-Popović Milica

    2014-01-01

    Full Text Available Individual housing units in Serbia have been studied from the aspect of applied technical solutions. Analyzed data have been collected during a field research in accordance with the current administrative regional division, and they represent a basis for definition of regional typology of individual housing units. Characteristic types of objects of each region’s typology have been further analyzed. Upon these analyses regional characteristics of individual housing units regarding applied construction types, building technologies and materials have been defined and presented. [Projekat Ministarstva nauke Republike Srbije, br. TR 36034: Investigation and Systematization of Serbian Housing in Context of Globalization and European Integration in the Framework of Quality and Living-Standard Improvement

  10. Stand-alone photovoltaic system: study of a modular concept with distributed communication and control units; Systeme photovoltaique autonome: etude d'une structure modulaire a gestion repartie

    Energy Technology Data Exchange (ETDEWEB)

    Neusser, A

    2004-09-15

    This thesis concerns an innovative photovoltaic system concept, which is modular am where the standardisation of all of the components is possible. Lead-acid batteries tare used to store the energy. The main objective of this project is the improvement of the battery management process in the system. As the batteries are the weak point of the system, a new battery charger is developed aiming at a longer life-span and a homogeneous ageing rate for all of them. This charger permits energy exchanges, which are co-ordinated by a communication system. We use a DC/DC converter as power electronics for battery charging. PSpice simulations and tests verify its performance. Simulations with Matlab Simulink show the auto-equalization tendency of the chosen battery management method. In addition, an experimentation under real conditions validates the beneficial effect on the state of health of the batteries. (author)

  11. Housing growth in and near United States protected areas limits their conservation value.

    Science.gov (United States)

    Radeloff, Volker C; Stewart, Susan I; Hawbaker, Todd J; Gimmi, Urs; Pidgeon, Anna M; Flather, Curtis H; Hammer, Roger B; Helmers, David P

    2010-01-12

    Protected areas are crucial for biodiversity conservation because they provide safe havens for species threatened by land-use change and resulting habitat loss. However, protected areas are only effective when they stop habitat loss within their boundaries, and are connected via corridors to other wild areas. The effectiveness of protected areas is threatened by development; however, the extent of this threat is unknown. We compiled spatially-detailed housing growth data from 1940 to 2030, and quantified growth for each wilderness area, national park, and national forest in the conterminous United States. Our findings show that housing development in the United States may severely limit the ability of protected areas to function as a modern "Noah's Ark." Between 1940 and 2000, 28 million housing units were built within 50 km of protected areas, and 940,000 were built within national forests. Housing growth rates during the 1990s within 1 km of protected areas (20% per decade) outpaced the national average (13%). If long-term trends continue, another 17 million housing units will be built within 50 km of protected areas by 2030 (1 million within 1 km), greatly diminishing their conservation value. US protected areas are increasingly isolated, housing development in their surroundings is decreasing their effective size, and national forests are even threatened by habitat loss within their administrative boundaries. Protected areas in the United States are thus threatened similarly to those in developing countries. However, housing growth poses the main threat to protected areas in the United States whereas deforestation is the main threat in developing countries.

  12. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test.

    Science.gov (United States)

    Gonfiotti, Bruno; Paci, Sandro

    2018-03-01

    During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA) in a Nuclear Power Plant (NPP). Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR) fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV) have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP) behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel.

  13. Stand-alone containment analysis of Phébus FPT tests with ASTEC and MELCOR codes: the FPT-2 test

    Directory of Open Access Journals (Sweden)

    Bruno Gonfiotti

    2018-03-01

    Full Text Available During the last 40 years, many studies have been carried out to investigate the different phenomena occurring during a Severe Accident (SA in a Nuclear Power Plant (NPP. Such efforts have been supported by the execution of different experimental campaigns, and the integral Phébus FP tests were probably some of the most important experiments in this field. In these tests, the degradation of a Pressurized Water Reactor (PWR fuel bundle was investigated employing different control rod materials and burn-up levels in strongly or weakly oxidizing conditions. From the findings on these and previous tests, numerical codes such as ASTEC and MELCOR have been developed to analyze the evolution of a SA in real NPPs. After the termination of the Phébus FP campaign, these two codes have been furthermore improved to implement the more recent findings coming from different experimental campaigns. Therefore, continuous verification and validation is still necessary to check that the new improvements introduced in such codes allow also a better prediction of these Phébus tests. The aim of the present work is to re-analyze the Phébus FPT-2 test employing the updated ASTEC and MELCOR code versions. The analysis focuses on the stand-alone containment aspects of this test, and three different spatial nodalizations of the containment vessel (CV have been developed. The paper summarizes the main thermal-hydraulic results and presents different sensitivity analyses carried out on the aerosols and fission products (FP behavior. When possible, a comparison among the results obtained during this work and by different authors in previous work is also performed. This paper is part of a series of publications covering the four Phébus FP tests using a PWR fuel bundle: FPT-0, FPT-1, FPT-2, and FPT-3, excluding the FPT-4 one, related to the study of the release of low-volatility FP and transuranic elements from a debris bed and a pool of melted fuel. Keywords: Safety

  14. Alternative route of process modification for biofuel production by embedding the Fischer-Tropsch plant in existing stand-alone power plant (10 MW) based on biomass gasification - Part I: A conceptual modeling and simulation approach (a case study in Thailand)

    DEFF Research Database (Denmark)

    Hunpinyo, Piyapong; Cheali, Peam; Narataruksa, Phavanee

    2014-01-01

    a base case process model coupled with techno-economic evaluation for the FT synthesis. In particular, the FT process configurations are designed and assessed using current kinetic laboratory data by our research group for modeling specific reactions in PFR reactor. The calculation of equipment sizing......The utilization of syngas shows a highly potential to improve the economic potential of the stand-alone power unit-based gasification plants as well as enhancing the growing demand of transportation fuels. The thermochemical conversion of biomass via gasification to heat and power generations from...... incurred several major unit operations is performed for once-through mode (no recycles of unconverted syngas) with electricity co-production. This study provides a detailed base-case model for the synthesis with the capacities of 1, 2 and 3 MW of syngas technology sharing and the comparison between...

  15. Measure Guideline. Five Steps to Implement the Public Housing Authority Energy-Efficient Unit Turnover Checklist

    Energy Technology Data Exchange (ETDEWEB)

    Liaukus, Christine [Building American Research Alliance, Kent, WA (United States)

    2015-07-09

    Five Steps to Implementing the PHA Energy Efficient Unit Turnover Package (ARIES, 2014) is a guide to prepare for the installation of energy efficient measures during a typical public housing authority unit turnover. While a PHA is cleaning, painting and readying a unit for a new resident, there is an opportunity to incorporate energy efficiency measures to further improve the unit's performance. The measures on the list are simple enough to be implemented by in-house maintenance personnel, inexpensive enough to be folded into operating expenses without needing capital budget, and fast enough to implement without substantially changing the number of days between occupancies, a critical factor for organizations where the demand for dwelling units far outweighs the supply. The following guide lays out a five step plan to implement the EE Unit Turnover Package in your PHA, from an initial Self-Assessment through to Package Implementation.

  16. Post-processing in cardiovascular computed tomography. Performance of a client server solution versus a stand-alone solution; Bildnachverarbeitung in der kardiovaskulaeren Computertomografie. Performance von Client-Server- versus Einzelplatzloesung

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, C.; Foldyna, B.; Andres, C.; Grothoff, M.; Nitzsche, S.; Gutberlet, M.; Lehmkuhl, L. [Leipzig Univ. - Herzzentrum (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Boehmer-Lasthaus, S. [Siemens Healthcare Sector, Erlangen (Germany). Imaging and Therapy Div.

    2014-12-15

    Purpose: To compare the performance of server-based (CSS) versus stand-alone post-processing software (ES) for the evaluation of cardiovascular CT examinations (cvCT) and to determine the crucial steps. Data of 40 patients (20 patients for coronary artery evaluation and 20 patients prior to transcatheter aortic valve implantation [TAVI]) were evaluated by 5 radiologists with CSS and ES. Data acquisition was performed using a dual-source 128-row CT unit (SOMATOM Definition Flash, Siemens, Erlangen, Germany) and a 64-row CT unit (Brilliance 64, Philips, Hamburg, Germany). The following workflow was evaluated: Data loading, aorta and coronary segmentation, curved multiplanar reconstruction (cMPR) and 3 D volume rendering technique (3D-VRT), measuring of coronary artery stenosis and planimetry of the aortic annulus. The time requirement and subjective quality for the workflow were evaluated. The coronary arteries as well as the TAVI data could be evaluated significantly faster with CSS (5.5 ± 2.9 min and 8.2 ± 4.0 min, respectively) than with ES (13.9 ± 5.2 min and 15.2 ± 10.9 min, respectively, p = 0.01). Segmentation of the aorta (CSS: 1.9 ± 2.0 min, ES: 3.7 ± 3.3 min), generating cMPR of coronaries (CSS: 0.5 ± 0.2 min, ES: 5.1 ± 2.6 min), aorta and iliac vessels (CSS: 0.5 ± 0.4 min and 0.4 ± 0.4 min, respectively, ES: 1.6 ± 0.7 min and 2.8 ± 3 min, respectively) could be performed significantly faster with CSS than with ES with higher quality of cMPR, measuring of coronary stenosis and 3D-VRT (p < 0.05). Evaluation of cvCT can be accomplished significantly faster and better with CSS than with ES. The segmentation remains the most time-consuming workflow step, so optimization of segmentation algorithms could improve performance even further.

  17. Wireless network of stand-alone end effect probes for soil in situ permittivity measurements over the 100MHZ-6GHz frequency range

    Science.gov (United States)

    Demontoux, François; Bircher, Simone; Ruffié, Gilles; Bonnaudiin, Fabrice; Wigneron, Jean-Pierre; Kerr, Yann

    2017-04-01

    , it should be useful to install many probes on the same site to obtain permittivity measurements over a large area. To reach this goal, the probes should communicate with each other to send data to a record device. Furthermore, it is needed to record measurements over a long time period (many months) to study the in-situ dielectric soil property variations according to changing weather conditions and seasonal trends. The goal of the research work presented is to develop a dielectric sensor system based on end effect probes able to communicate the data using wireless technology. It must be stand-alone from an electric and data recording point of view so it must integrate a VNA circuit instead of the ANRITSU VNA used for the moment. The LoRa wireless technology has been selected because of its low electric consumption and the large distance between equipment available. LoRaWAN™ is a Low Power Wide Area Network specification intended for wireless battery operated devices. The LoRaWAN data rates range from 0.3 kbps to 50 kbps which is sufficient for our probes' data exchanges. We will present the work done to perform the VNA and the LoRa communication board as well as the work done to improve the probes and the permittivity computation algorithm.

  18. High Performance Residential Housing Units at U.S. Coast Guard Base Kodiak: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.; Hickey, J.

    2013-10-01

    The United States Coast Guard (USCG) constructs residential housing throughout the country using a basic template that must meet the minimum Leadership in Energy and Environmental Design (LEED) Silver criteria or better for the units. In Kodiak, Alaska, USCG is procuring between 24 and 100 residential multi-family housing units. Priorities for the Kodiak project were to reduce overall energyconsumption by at least 20% over existing units, improve envelope construction, and evaluate space heating options. USCG is challenged with maintaining similar existing units that have complicated residential diesel boilers. Additionally, fuel and material costs are high in Kodiak. While USCG has worked to optimize the performance of the housing units with principles of improved buildingenvelope, the engineers realize there are still opportunities for improvement, especially within the heating, ventilation, and air conditioning (HVAC) system and different envelope measures. USCG staff also desires to balance higher upfront project costs for significantly reduced life-cycle costs of the residential units that have an expected lifetime of 50 or more years. To answer thesequestions, this analysis used the residential modeling tool BEoptE+ to examine potential energy- saving opportunities for the climate. The results suggest criteria for achieving optimized housing performance at the lowest cost. USCG will integrate the criteria into their procurement process. To achieve greater than 50% energy savings, USCG will need to specify full 2x 6 wood stud R-21 insulationwith two 2 inches of exterior foam, R-38 ceiling insulation or even wall insulation in the crawl space, and R-49 fiberglass batts in a the vented attic. The air barrier should be improved to ensure a tight envelope with minimal infiltration to the goal of 2.0 ACH50. With the implementation of an air source heat pump for space heating requirements, the combination of HVAC and envelope savings inthe residential unit can save

  19. Study of a stand alone power system based on a photovoltaic field, an electrolyser and a fuel cell: test bench and modelling; Etude d'un systeme autonome de production d'energie couplant un champ photovoltaique, un electrolyseur et une pile a combustible: realisation d'un banc d'essai et modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Busquet, S.

    2003-12-01

    Our energetic future has to be based on non-polluting energies with long-term resources. Renewable energies are the best candidates but as their production is intermittent, storage way is necessary as well efficient as environmentally friendly. Coupled an electrolyser and a fuel cell allows to store electricity in gas form and furthermore to produce heat energy. The goal of this work is to evaluate performances of a stand-alone power system, producing electricity and heat, coupling a photovoltaic field and a hydrogen storage system, made of an electrolyser, a gas storage unit and a fuel cell. Hydrogen is the unique way to store electricity. To complete this task, two tools have been developed: a 3,6 kW test bench and a simulation tool. To select the test bench, a bibliographic study enables to collect the necessary information to size and to choice the system and its components. The low availability of components adapted to our application, forces us to create new devices (electrolyser, fuel cell, power management unit). The test bench is automatic and safe. Experimental analysis evaluates the efficiency of the hydrogen storage system, determining the different losses occurring in each component. Modifications are proposed to increase the performances of the storage system. The simulation tool enables to plan the operating of the test bench for a fixed load and place. This model can simulate any system based on experimental data of each component. Simulation results enable to characterise the functioning of the test bench in a stand-alone operation, to determine its performances and to evaluate the influence of the different losses. (author)

  20. Searching for Housing as a Battered Woman: Does Discrimination Affect Reported Availability of a Rental Unit?

    Science.gov (United States)

    Barata, Paula C.; Stewart, Donna E.

    2010-01-01

    Individual battered women have reported experiencing housing discrimination, but the extent of this problem has not been examined. This research used two experiments and a survey to determine if landlord discrimination could keep women from accessing rental units. In Study 1, a confederate asked 181 landlords about the availability of a rental…

  1. Institutional investment in social rental housing : France, the Netherlands and the United Kingdom explored

    NARCIS (Netherlands)

    Haffner, M.E.A.; Hoekstra, J.S.C.M.; Tang, C.; Oxley, M.

    2015-01-01

    In the United Kingdom, social landlords are facing decreasing governmental financial support for them to fulfil their role in the provision of social housing, which has led to increasing pressure on them to rely on private capital. Traditionally, bank loans were the main source of private capital,

  2. IEA PVPS Task 3. Use of photovoltaic systems in stand-alone and island applications. 'Swiss participation'; IEA PVPS Task 3. Use of photovoltaic systems in stand-alone and island applications. 'Participation Suisse'

    Energy Technology Data Exchange (ETDEWEB)

    Villoz, M. [Dynatex SA, Morges (Switzerland)

    2004-07-01

    This report describes the work done during five years of the second phase of Task 3 of the photovoltaic power systems programme of the International Energy Agency (IEA-PVPS). Task 3 activities were concentrated on stand-alone photovoltaic systems with the main effort on improving the quality and reducing the cost of these systems. The work was divided in 2 sub-tasks whose first one was concentrated on quality insurance schemes and second one on technical recommendations coming from practical experience. Twelve original reports have been published covering topics that can be sorted in 4 categories: the first one is dedicated on quality issues with a review of existing standards in the participating countries and a double paper giving quality assurance recommendations on project management and examples of applying these rules in practical cases. The second category dwelled on photovoltaic systems with papers on charge controllers, on lightning protection and monitoring of systems. The third category presents interesting studies on the storage of energy which remains the main subject where improvements should be made in order to lower the cost of energy; four papers describe the management and the test procedures of lead-acid batteries, how to choose a lead-acid battery and finally are there alternatives to lead-acid batteries for the storage of photovoltaic electricity. The last category worked on loads and users of renewable energy and gives a large amount of experience with loads, how to choose them and how the energy can be better used through demand side management. (author)

  3. Impact of Brexit on the United Kingdom’s Housing Market

    OpenAIRE

    Syromiatnikova, Sofia

    2017-01-01

    This thesis aims to analyse the changes in the real estate market in the United Kingdom and trace and identify the factors that would trigger a price change. The dissertation investigates the possible change in the value of housing caused by Brexit, which is a specific group of investment assets and a major component of household wealth for the UK. Understanding the nature and degree of change in housing prices will make market participants aware of the size of their risk exposure and can hel...

  4. Seismic response analysis and upgrading design of pump houses of Kozloduy NPP units 5 and 6

    International Nuclear Information System (INIS)

    Jordanov, M.; Marinov, M.; Krutzik, N.

    2001-01-01

    The main objective of the presented project was to perform a feasibility study for seismic/structural evaluation of the safety related structures at Kozloduy NPP Units 5 and 6 for the new site seismicity and determine if they satisfy current international safety standards. The evaluation of the Pump House 3 (PH3) building is addressed in this paper, which was carried out by applying appropriate modeling techniques combined with failure mode and seismic margin analyses. The scope of the work defined was to present the required enhancement of the seismic capacity of the Pump House structures.(author)

  5. Life-Cycle Assessment of Prototype Unit of Emergency Housing. The search for the zero impact

    Directory of Open Access Journals (Sweden)

    J. M. Ros García

    2017-09-01

    Full Text Available Prototype Unit of Emergency Housing (PUEH is the result of the Applied Research Project VEM (Military Emergency Housing developed in collaboration with Escuela Politécnica Superior (Universidad CEU and the company Air-bus Defense & Space. It is designed as a modular and industrialized unit of basic habitability, with programmed and expandable growth, designed to provide shelter and protection in environments of humanitarian crises or contingencies of social vulnerability in order to ensure sustainable habitat for emergencies.The influence of the construction processes and materials involved in the manufacture of this PUEH have on the environment, analyzed using the methodology of life-cycle assessment (LCA, considered especially critical recycling the mate-rials used. Thus, in order to reduce the environmental impact environmental, each of the component parts of the developed prototype unit are quantified, evaluating the benefits resulting from the methodology DfMA (Design for Manufacturing and Assembly.

  6. Simulation of a passive house coupled with a heat pump/organic Rankine cycle reversible unit

    DEFF Research Database (Denmark)

    Dumont, Olivier; Carmo, Carolina; Randaxhe, François

    2014-01-01

    This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible ...... presents a higher global COP because the heat produced on the roof can heat the storage directly.......This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible...... modes that need to be chosen optimally depending on the weather conditions, the heat demand and the temperature level of the storage. The ORC mode is activated, as long as the heat demand of the house is covered by the storage to produce electricity based upon the heat generated by the solar roof...

  7. Search Improvement Process-Chaotic Optimization-Particle Swarm Optimization-Elite Retention Strategy and Improved Combined Cooling-Heating-Power Strategy Based Two-Time Scale Multi-Objective Optimization Model for Stand-Alone Microgrid Operation

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2017-11-01

    Full Text Available The optimal dispatching model for a stand-alone microgrid (MG is of great importance to its operation reliability and economy. This paper aims at addressing the difficulties in improving the operational economy and maintaining the power balance under uncertain load demand and renewable generation, which could be even worse in such abnormal conditions as storms or abnormally low or high temperatures. A new two-time scale multi-objective optimization model, including day-ahead cursory scheduling and real-time scheduling for finer adjustments, is proposed to optimize the operational cost, load shedding compensation and environmental benefit of stand-alone MG through controllable load (CL and multi-distributed generations (DGs. The main novelty of the proposed model is that the synergetic response of CL and energy storage system (ESS in real-time scheduling offset the operation uncertainty quickly. And the improved dispatch strategy for combined cooling-heating-power (CCHP enhanced the system economy while the comfort is guaranteed. An improved algorithm, Search Improvement Process-Chaotic Optimization-Particle Swarm Optimization-Elite Retention Strategy (SIP-CO-PSO-ERS algorithm with strong searching capability and fast convergence speed, was presented to deal with the problem brought by the increased errors between actual renewable generation and load and prior predictions. Four typical scenarios are designed according to the combinations of day types (work day or weekend and weather categories (sunny or rainy to verify the performance of the presented dispatch strategy. The simulation results show that the proposed two-time scale model and SIP-CO-PSO-ERS algorithm exhibit better performance in adaptability, convergence speed and search ability than conventional methods for the stand-alone MG’s operation.

  8. The international phase 4 validation study of the EORTC QLQ-SWB32: a stand-alone measure of spiritual wellbeing (SWB) for people receiving palliative care for cancer

    OpenAIRE

    Vivat, B.; Young, T.; Winstanley, J.; Arraras, J.; Black, K.; Boyle, F.; Brédart, A.; Costantini, A.; Guo, J.; Irarrazaval, M. E.; Kobayashi, K.; Kruizinga, R.; Navarro, M.; Omidvari, S.; Rohde, G. E.

    2017-01-01

    The EORTC Quality of Life (QL) Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual wellbeing (SWB) for palliative cancer patients. Participants (n= 451) - from 14 countries on four continents; 54% female; 188 Christian, 50 Muslim, 156 with no religion - completed a provisional 36-item measure of SWB plus the EORTC QLQ-C15-PAL (PAL), then took part in a structured debriefing interview. All items showe...

  9. Feasibility Analysis and Simulation of a Stand-Alone Photovoltaic Energy System for Electricity Generation and Environmental Sustainability – Equivalent to 650VA Fuel-Powered Generator – Popularly Known as “I Pass My Neighbour”

    International Nuclear Information System (INIS)

    Ani, Vincent Anayochukwu

    2015-01-01

    Photovoltaic (PV) power system can be used to replace wholly 650VA generator for electricity generation for household use in Nigeria. This paper presented the feasibility analysis of load data and simulation study of a stand-alone PV power system that produced the electrical needs of a household. This study is based on designing of PV energy system for household use. The patterns of load consumption within the household were studied and suitably modeled for simulation. The simulation study indicates that energy requirements to provide electricity, which is equivalent to 650VA generator for household use in Nigeria, can be accomplished by 520 W solar PV array, 2312 Ah nominal capacity battery, and a 1 kW DC/AC inverter. This would be suitable for deployment of 100% clean energy for environmental sustainability and uninterruptable power performance in the household. The results of this research show that, with a low-power consuming appliances, it is possible to meet the entire annual electricity demand of a single household solely through a stand-alone PV energy supply. Installing solar panels by most Nigerian home can significantly reduce home reliance on government power thereby reduce the strain on the current capacity of our power generation infrastructure. A detailed design and description of the system were presented in this paper.

  10. Feasibility Analysis and Simulation of a Stand-Alone Photovoltaic Energy System for Electricity Generation and Environmental Sustainability – Equivalent to 650VA Fuel-Powered Generator – Popularly Known as “I Pass My Neighbour”

    Energy Technology Data Exchange (ETDEWEB)

    Ani, Vincent Anayochukwu, E-mail: vincent_ani@yahoo.com [Department of Electronic Engineering, University of Nigeria Nsukka, Nsukka (Nigeria)

    2015-09-11

    Photovoltaic (PV) power system can be used to replace wholly 650VA generator for electricity generation for household use in Nigeria. This paper presented the feasibility analysis of load data and simulation study of a stand-alone PV power system that produced the electrical needs of a household. This study is based on designing of PV energy system for household use. The patterns of load consumption within the household were studied and suitably modeled for simulation. The simulation study indicates that energy requirements to provide electricity, which is equivalent to 650VA generator for household use in Nigeria, can be accomplished by 520 W solar PV array, 2312 Ah nominal capacity battery, and a 1 kW DC/AC inverter. This would be suitable for deployment of 100% clean energy for environmental sustainability and uninterruptable power performance in the household. The results of this research show that, with a low-power consuming appliances, it is possible to meet the entire annual electricity demand of a single household solely through a stand-alone PV energy supply. Installing solar panels by most Nigerian home can significantly reduce home reliance on government power thereby reduce the strain on the current capacity of our power generation infrastructure. A detailed design and description of the system were presented in this paper.

  11. Emergy Evaluation of Dwelling Operation in Five Housing Units of Montreal Island, Canada

    Directory of Open Access Journals (Sweden)

    Ricardo Enrique Vega-Azamar

    2017-04-01

    Full Text Available Sustainability of cities and the environmental implications of high resource utilization by the domestic sector are growing concerns related to urban regions. Well-informed urban planning decision-making is an essential tool to help in the task and, for that, an important point to consider is the influence of parameters like residential density and housing typology on the intensity of resource utilization. Emergy synthesis, a life-cycle energy analysis methodological approach that considers the interaction of natural and human-made flows, was used to evaluate the environmental support for dwelling operational stage in five typical present-day housing units on the island of Montreal. As expected, resource utilization, measured as total emergy used, was positively correlated to housing unit size both with respect to number of occupants and dwelling size. Results suggest that variables affecting notably the intensity of resource utilization are per household income and per dweller habitable space and, while a higher income increased per capita emergy in all cases, increasing space availability per resident did not result in a decrease of empower density after 50 m2/person. Future work should consider lower and higher densities and analyses at the scale of blocks, neighborhoods and urban planning zones.

  12. Prospective Trial of House Staff Time to Response and Intervention in a Surgical Intensive Care Unit: Pager vs. Smartphone.

    Science.gov (United States)

    Tatum, James M; White, Terris; Kang, Christopher; Ley, Eric J; Melo, Nicolas; Bloom, Matthew; Alban, Rodrigo F

    The objective of the study was to characterize house staff time to response and intervention when notified of a patient care issue by pager vs. smartphone. We hypothesized that smartphones would reduce house staff time to response and intervention. Prospective study of all electronic communications was conducted between nurses and house staff between September 2015 and October 2015. The 4-week study period was randomly divided into two 2-week study periods where all electronic communications between intensive care unit nurses and intensive care unit house staff were exclusively by smartphone or by pager, respectively. Time of communication initiation, time of house staff response, and time from response to clinical intervention for each communication were recorded. Outcomes are time from nurse contact to house staff response and intervention. Single-center surgical intensive care unit of Cedars-Sinai Medical Center in Los Angeles, California, an academic tertiary care and level I trauma center. All electronic communications occurring between nurses and house staff in the study unit during the study period were considered. During the study period, 205 nurse-house staff electronic communications occurred, 100 in the phone group and 105 in the pager group. House staff response to communication time was significantly shorter in the phone group (0.5 [interquartile range = 1.7] vs. 2 [3]min, p house staff intervention after response was also significantly more rapid in the phone group (0.8 [1.7] vs. 1 [2]min, p = 0.003). Dedicated clinical smartphones significantly decrease time to house staff response after electronic nursing communications compared with pagers. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring.

    Science.gov (United States)

    Zajonz, Dirk; Franke, Anne-Catherine; von der Höh, Nicolas; Voelker, Anna; Moche, Michael; Gulow, Jens; Heyde, Christoph-Eckhard

    2014-01-01

    The stand-alone treatment of degenerative cervical spine pathologies is a proven method in clinical practice. However, its impact on subsidence, the resulting changes to the profile of the cervical spine and the possible influence of clinical results compared to treatment with additive plate osteosynthesis remain under discussion until present. This study was designed as a retrospective observational cohort study to test the hypothesis that radiographic subsidence of cervical cages is not associated with adverse clinical outcomes. 33 cervical segments were treated surgically by ACDF with stand-alone cage in 17 patients (11 female, 6 male), mean age 56 years (33-82 years), and re-examined after eight and twenty-six months (mean) by means of radiology and score assessment (Medical Outcomes Study Short Form (MOS-SF 36), Oswestry Neck Disability Index (ONDI), painDETECT questionnaire and the visual analogue scale (VAS)). Subsidence was observed in 50.5% of segments (18/33) and 70.6% of patients (12/17). 36.3% of cases of subsidence (12/33) were observed after eight months during mean time of follow-up 1. After 26 months during mean time of follow-up 2, full radiographic fusion was seen in 100%. MOS-SF 36, ONDI and VAS did not show any significant difference between cases with and without subsidence in the two-sample t-test. Only in one type of scoring (painDETECT questionnaire) did a statistically significant difference in t-Test emerge between the two groups (p = 0.03; α = 0.05). However, preoperative painDETECT score differ significantly between patients with subsidence (13.3 falling to 12.6) and patients without subsidence (7.8 dropped to 6.3). The radiological findings indicated 100% healing after stand-alone treatment with ACDF. Subsidence occurred in 50% of the segments treated. No impact on the clinical results was detected in the medium-term study period.

  14. Performance evaluation of a stand-alone solar dish Stirling system for power generation suitable for off-grid rural electrification

    International Nuclear Information System (INIS)

    Kadri, Y.; Hadj Abdallah, H.

    2016-01-01

    alternative side. Detailed tests of the proposed hybrid configuration was implemented in Matlab/Simulink software, by taking as a case study a measured load profile for a rural house and solar radiation data at the target area. The analysis of simulation results has shown that solar dish Stirling/synchronous generator system achieves the objectives of system autonomy and power supply stability. The effectiveness of the management strategy was also proved. It has been obtained that the variable speed Stirling/generator system is capable to feed an uncontrollable load under variations of climatic conditions during hot, moderate and cold seasons, in remote areas in Tunisia.

  15. A Formaldehyde Exposure Assessment Tool for Occupants of FEMA Temporary Housing Units

    Energy Technology Data Exchange (ETDEWEB)

    Parthasarathy, Srinandini; Spears, Michael; Maddalena, Randy L.; Russell, Marion L; Apte, Michael G.

    2010-10-01

    The report outlines the methodology used to develop a web-based tool to assess the formaldehyde exposure of the occupants of Federal Emergency Management Administration (FEMA) temporary housing units (THUs) after Hurricanes Katrina and Rita in 2005. Linear regression models were built using available data to retrospectively estimate the indoor temperature and relative humidity, formaldehyde emission factors and concentration, and hence the formaldehyde exposures. The interactive web-tool allows the user to define the inputs to the model to evaluate formaldehyde exposures for different scenarios.

  16. An application of the gas-fired chilling and heating units to domestic houses

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.H.; Yang, Y.M.; Chae, J.M.; Bang, H.S.; Kwon, O.B.; Yoo, S.I.; Kim, T.H. [R and D Center, Korea Gas Co. (Korea); Lee, T.W.; Kim, T.H.; Kim, B.H.; Hwang, I.J.; Kim, J.Y.; Kim, C.D.; Park, S.J. [Korea Institute of Construction Technology (Korea)

    1999-10-01

    Following researches and considerations were performed in this study for an efficient application of gas-fired chilling and heating units to the residential buildings. (1) Status of domestic cooling and heating for residential building. (2) Various introduction schemes of outdoor unit. (3) Design exclusive area for the gas appliance and installation of it. (4) Ventilation of exhaust gas and heat. (5) Prepare the installation specifications or standards for gas-fired chilling and heating units. (6) Design technique of plumbing for cooling and heating. (7) Evaluation of unit's capacity considering the thermal load of domestic buildings. (8) Cooling and heating system with the unit. (9) Fundamental test for evaluation of applicability. (10) Actual design and construction of experimental house for an application and a demonstration of the developed gas units. (11) Field test for cooling and heating. (12) Evaluation of economic efficiency. (13) Establish a business potential. (14) Establishment of legal and systematic support, energy rate. (15) Troubleshooting in the course of development and application of the new gas appliance. 41 refs., 214 figs., 52 tabs.

  17. Research and development of utilization system of photovoltaic power generation. R and D of stand-alone power system (for marine use)

    Energy Technology Data Exchange (ETDEWEB)

    1986-08-01

    This is an annual report for 1985 for NEDO -contracted project. The project aims at establishing an efficient, stable power generating solar cell technology and developing a power supply system for the ocean development. In order to install an independent off-shore power supply system for the marine ranch at Kamiura, Oita Prefecture, a frame berge was constructed on the Tsuinoura pier and an annularly arranged disc type solar cell with the center tapered at 4 % in an umbrella shape towards outside. Designed capacity was 10 KWp maximum output, and total 11 KVA (1 KVA at heavy duty load and 10 KVA at sun-shining load). The power source system consists of units for solar cell, power storage, control, orthogonal conversion, and of various loads. The system can make a normal observation by a wireless data transmission from off-shore onto the ground. (2 figs, 4 tabs)

  18. Smart house-based optimal operation of thermal unit commitment for a smart grid considering transmission constraints

    Science.gov (United States)

    Howlader, Harun Or Rashid; Matayoshi, Hidehito; Noorzad, Ahmad Samim; Muarapaz, Cirio Celestino; Senjyu, Tomonobu

    2018-05-01

    This paper presents a smart house-based power system for thermal unit commitment programme. The proposed power system consists of smart houses, renewable energy plants and conventional thermal units. The transmission constraints are considered for the proposed system. The generated power of the large capacity renewable energy plant leads to the violated transmission constraints in the thermal unit commitment programme, therefore, the transmission constraint should be considered. This paper focuses on the optimal operation of the thermal units incorporated with controllable loads such as Electrical Vehicle and Heat Pump water heater of the smart houses. The proposed method is compared with the power flow in thermal units operation without controllable loads and the optimal operation without the transmission constraints. Simulation results show the validation of the proposed method.

  19. Research and development of utilization system of photovoltaic power generation. R and D of stand-alone system (desalination system for remote island-reverse osmosis)

    Energy Technology Data Exchange (ETDEWEB)

    1986-08-01

    This system is an independent system which utilizes DC power obtained by a solar cell for the power source for a sea water desalination plant. The system is constructed of 2 series of a reverse osmosis membrane module system by which the power storage requirement in the battery is minimized by storing in the form of water instead. Effective battery capacity is 46.2 KWH which corresponds to the operation of 0.7 days. Hoso-jima in the central part of the Seto Inland Sea is estimated as the plant location and satisfies the conditions of this verification test. It is being examined to use the solar cells of single and poly crystal types as they have been often practically used to a considerable extent, because the test plant is going to be used as a commercial plant after the test operation is completed. Nominal capacity of 0.55 m/sup 2//h was set for the reverse osmosis sea water desalination unit on the basis of 4.5 m/sup 2//d (a daily average for the agricultural water required for 1,000 m/sup 2/ hydroponic area). Annual average water production is roughly 5.3 m/sup 2//d. (2 figs, 1 tab)

  20. Study on photovoltaic power systems. Development of dispersed stand-alone system (seawater desalination system for remote island areas-osmosis)

    Energy Technology Data Exchange (ETDEWEB)

    1987-09-01

    This study deals with development of a system of seawater osmosis desalination for remote island areas and agricultural-process water-supply. The demonstration system, installed in Hosojima, was simulated for examination. The yearly-averaged generated electric energy was 76 kWh/day, and the consumed energy 72 kWh/day. The calculated water productivity was 5.5 m/sup 3//day in the first step, and 4.9 m/sup 3//day in the second. This amount had a high balance with that required for hydropholic water of 4.5 m/sup 3//day. The generated output was 30.8 kWp (power range of 10-100 kW) for the solar cells, and 840 Ah for the electric batteries. The generated direct-current power was supplied to the loads without use of a DA converter, which contributes to the high energy efficiency and the inexpensiveness of the system. This system can be unattendantly operated in the normal conditions. After construction of the demonstration plant, the respective units and the total system were adjusted to give good results. (1 fig, 1 tab)

  1. Techno-economic analysis of stand alone solar pv systems for remote base stations in Ghana. (a case study at Abofrem vodafone cell site)

    International Nuclear Information System (INIS)

    Denkyira, Samuel

    2015-06-01

    Information and Communications Technologies (ICT) have become an important part of today’s global economy. ICT infrastructural development is developing at a very fast pace in Ghana. Growth is above the 1.1% average for Sub-Saharan Africa. The growth in the sector has meant a massive investment in telecommunication infrastructure such as base stations from telecom companies such as Vodafone, Millicom, Glo, Espresso, MTN etc. Hundreds of base stations have been installed all over the country. Currently base stations depend mainly on the national grid, with diesel generators as backups, for its power requirement. In some remote or hilly areas where there are no grid supplied electricity, base stations are usually powered with diesel fuelled generators since lengthy grid extensions may not be cost effective. In addition to high fuel delivery and consumption costs, maintenance of the generators can also be expensive in terms of parts and labour time working on the unit. There are also concerns about environmental pollution using diesel generators. Photovoltaic technology has the ability to convert solar energy into electricity consuming no fossil fuels, using no moving parts, creating no pollution and noise, and lasting for years with little maintenance. The environmental, noise, reliability and power availability benefits of the PV system make it an attractive option. Ghana, being a few degrees north of the equator, is endowed with enormous solar energy resource spread across the entire country. Daily solar radiation level ranges from 4 kWh/m 2 to 6 kWh/m 2 . The annual sunshine duration ranges between 1800 to 3000 hours offering very high potential for grid connected and off grid applications. In this thesis work, the use of solar PV technology as a cost effective source of power for cellular base stations in remote or hilly areas, far off the national grid, is reviewed. RETScreen software is used to determine the technical and financial viability of the PV system

  2. Impact of a mental health training course for correctional officers on a special housing unit.

    Science.gov (United States)

    Parker, George F

    2009-05-01

    This study determined the impact of a ten-hour mental health training program developed by the Indiana chapter of the National Alliance on Mental Illness (NAMI-Indiana) for correctional officers on a prison special housing ("supermax") unit. The training was delivered to all of the correctional officers on the unit in five weekly sessions and was repeated 15 months later for new unit staff. The number of incidents reported by unit staff in standard monthly reports, consisting of use of force by the officers and battery by bodily waste on the officers by the offenders, was compared for the nine months before and after both training sessions. Attendance at the initial training ranged from 48 to 57 officers per session, and on the basis of Likert ratings, training was well received by the officers. The total number of incidents, the use of force by the officers, and battery by bodily waste all declined significantly after the first mental health training, and the total number of incidents and battery by bodily waste declined significantly after the second training. The provision of ten hours of mental health training to correctional officers was associated with a significant decline in use of force and battery by bodily waste.

  3. Stand alone biofuel production from algae

    NARCIS (Netherlands)

    Wijffels, R.H.; Janssen, M.G.J.; Barbosa, M.J.

    2011-01-01

    In this feature, leading researchers in the field of microbial biotechnology speculate on the technical and conceptual developments that will drive innovative research and open new vistas over the next few years

  4. Informing Approaches in Establishing Stand Alone Community ...

    African Journals Online (AJOL)

    Literacy is usually considered the ability to read at a basic level. Now it is beginning to be defined more broadly to include applying reading, writing, and mathematical skills to obtain and use information and solve problems at levels of proficiency necessary to function in society, to achieve one's goals and develop one's ...

  5. Stand Alone Battery Thermal Management System

    Energy Technology Data Exchange (ETDEWEB)

    Brodie, Brad [Denso International America, Incorporated, Southfield, MI (United States)

    2015-09-30

    The objective of this project is research, development and demonstration of innovative thermal management concepts that reduce the cell or battery weight, complexity (component count) and/or cost by at least 20%. The project addresses two issues that are common problems with current state of the art lithium ion battery packs used in vehicles; low power at cold temperatures and reduced battery life when exposed to high temperatures. Typically, battery packs are “oversized” to satisfy the two issues mentioned above. The first phase of the project was spent making a battery pack simulation model using AMEsim software. The battery pack used as a benchmark was from the Fiat 500EV. FCA and NREL provided vehicle data and cell data that allowed an accurate model to be created that matched the electrical and thermal characteristics of the actual battery pack. The second phase involved using the battery model from the first phase and evaluate different thermal management concepts. In the end, a gas injection heat pump system was chosen as the dedicated thermal system to both heat and cool the battery pack. Based on the simulation model. The heat pump system could use 50% less energy to heat the battery pack in -20°C ambient conditions, and by keeping the battery cooler at hot climates, the battery pack size could be reduced by 5% and still meet the warranty requirements. During the final phase, the actual battery pack and heat pump system were installed in a test bench at DENSO to validate the simulation results. Also during this phase, the system was moved to NREL where testing was also done to validate the results. In conclusion, the heat pump system can improve “fuel economy” (for electric vehicle) by 12% average in cold climates. Also, the battery pack size, or capacity, could be reduced 5%, or if pack size is kept constant, the pack life could be increased by two years. Finally, the total battery pack and thermal system cost could be reduced 5% only if the system is integrated with the vehicle cabin air conditioning system. The reason why we were not able to achieve the 20% reduction target is because of the natural decay of the battery cell due to the number of cycles. Perhaps newer battery chemistries that are not so sensitive to cycling would have more potential for reducing the battery size due to thermal issues.

  6. Multi-site evaluation of a computer aided detection (CAD) algorithm for small acute intra-cranial hemorrhage and development of a stand-alone CAD system ready for deployment in a clinical environment

    Science.gov (United States)

    Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.

    2010-03-01

    Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.

  7. The international phase 4 validation study of the EORTC QLQ-SWB32: A stand-alone measure of spiritual well-being for people receiving palliative care for cancer.

    Science.gov (United States)

    Vivat, B; Young, T E; Winstanley, J; Arraras, J I; Black, K; Boyle, F; Bredart, A; Costantini, A; Guo, J; Irarrazaval, M E; Kobayashi, K; Kruizinga, R; Navarro, M; Omidvari, S; Rohde, G E; Serpentini, S; Spry, N; Van Laarhoven, H W M; Yang, G M

    2017-11-01

    The EORTC Quality of Life Group has just completed the final phase (field-testing and validation) of an international project to develop a stand-alone measure of spiritual well-being (SWB) for palliative cancer patients. Participants (n = 451)-from 14 countries on four continents; 54% female; 188 Christian; 50 Muslim; 156 with no religion-completed a provisional 36-item measure of SWB plus the EORTC QLQ-C15-PAL (PAL), then took part in a structured debriefing interview. All items showed good score distribution across response categories. We assessed scale structure using principal component analysis and Rasch analysis, and explored construct validity, and convergent/divergent validity with the PAL. Twenty-two items in four scoring scales (Relationship with Self, Relationships with Others, Relationship with Someone or Something Greater, and Existential) explained 53% of the variance. The measure also includes a global SWB item and nine other items. Scores on the PAL global quality-of-life item and Emotional Functioning scale weakly-moderately correlated with scores on the global SWB item and two of the four SWB scales. This new validated 32-item SWB measure addresses a distinct aspect of quality-of-life, and is now available for use in research and clinical practice, with a role as both a measurement and an intervention tool. © 2017 John Wiley & Sons Ltd.

  8. Field Derived Emission Factors For Formaldehyde and other Volatile Organic Compounds in FEMA Temporary Housing Units

    Energy Technology Data Exchange (ETDEWEB)

    Parthasarathy, Srinandini; Maddalena, Randy L.; Russell, Marion L.; Apte, Michael G.

    2010-10-01

    Sixteen previously occupied temporary housing units (THUs) were studied to assess emissions of volatile organic compounds. The whole trailer emission factors wereevaluated for 36 VOCs including formaldehyde. Indoor sampling was carried out in the THUs located in Purvis staging yard in Mississippi, USA. Indoor temperature andrelative humidity (RH) were also measured in all the trailers during sampling. Indoor temperatures were varied (increased or decreased) in a selection of THUs using theheating, ventilation and air conditioning (HVAC) systems. Indoor temperatures during sampling ranged from 14o C to 33o C, and relative humidity (RH) varied between 35percentand 74percent. Ventilation rates were increased in some trailers using bathroom fans and vents during some of the sampling events. Ventilation rates measured during some aselection of sampling events varied from 0.14 to 4.3 h-1. Steady state indoor formaldehyde concentrations ranged from 10 mu g-m-3 to 1000 mu g-m-3. The formaldehyde concentrations in the trailers were of toxicological significance. The effects of temperature, humidity and ventilation rates were also studied. A linearregression model was built using log of percentage relative humidity, inverse of temperature (in K-1), and inverse log ACH as continuous independent variables, trailermanufacturer as a categorical independent variable, and log of the chemical emission factors as the dependent variable. The coefficients of inverse temperature, log relativehumidity, log inverse ACH with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. The regression model wasfound to explain about 84percent of the variation in the dependent variable. Most VOC concentrations measured indoors in the Purvis THUs were mostly found to be belowvalues reported in earlier studies by Maddalena et al.,1,2 Hodgson et al.,3 and Hippelein4. Emissions of TMPB-DIB (a plasticizer found in vinyl products) were found

  9. ALDEHYDE AND OTHER VOLATILE ORGANIC CHEMICAL EMISSIONS IN FOUR FEMA TEMPORARY HOUSING UNITS ? FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Olivia; Maddalena, Randy L.; Russell, Marion; Sullivan, Douglas P.; Apte, Michael G.

    2008-05-04

    Four unoccupied FEMA temporary housing units (THUs) were studied to assess their indoor emissions of volatile organic compounds including formaldehyde. Measurement of whole-THU VOC and aldehyde emission factors (mu g h-1 per m2 of floor area) for each of the four THUs were made at FEMA's Purvis MS staging yard using a mass balance approach. Measurements were made in the morning, and again in the afternoon in each THU. Steady-state indoor formaldehyde concentrations ranged from 378 mu g m-3 (0.31ppm) to 632 mu g m-3 (0.52 ppm) in the AM, and from 433 mu g m-3 (0.35 ppm) to 926 mu g m-3 (0.78 ppm) in the PM. THU air exchange rates ranged from 0.15 h-1 to 0.39 h-1. A total of 45 small (approximately 0.025 m2) samples of surface material, 16 types, were collected directly from the four THUs and shipped to Lawrence Berkeley Laboratory. The material samples were analyzed for VOC and aldehyde emissions in small stainless steel chambers using a standard, accurate mass balance method. Quantification of VOCs was done via gas chromatography -- mass spectrometry and low molecular weight aldehydes via high performance liquid chromatography. Material specific emission factors (mu g h-1 per m2 of material) were quantified. Approximately 80 unique VOCs were tentatively identified in the THU field samples, of which forty-five were quantified either because of their toxicological significance or because their concentrations were high. Whole-trailer and material specific emission factors were calculated for 33 compounds. The THU emission factors and those from their component materials were compared against those measured from other types of housing and the materials used in their construction. Whole THU emission factors for most VOCs were typically similar to those from comparative housing. The three exceptions were exceptionally large emissions of formaldehyde and TMPD-DIB (a common plasticizer in vinyl products), and somewhat elevated for phenol. Of these three compounds

  10. Social work and the house of Islam: orienting practitioners to the beliefs and values of Muslims in the United States.

    Science.gov (United States)

    Hodge, David R

    2005-04-01

    Despite the media attention focused on the Islamic community after the terrorist attacks on the World Trade Center on September 11, 2001, Muslims remain one of the most misunderstood populations in the United States. Few articles have appeared in the social work literature orienting practitioners to the Islamic community, and much of the mainstream media coverage misrepresents the population. This article reviews the basic beliefs, practices, and values that commonly characterize, or inform, the House of Islam in the United States. The organizations that embody and sustain the Muslim communities that constitute the House of Islam are profiled, and areas of possible value conflicts are examined. The article concludes by offering suggestions for integrating the article's themes into practice settings. Particular attention is given to enhancing cultural competence and to suggestions for spiritual assessment and interventions.

  11. American Housing Survey (AHS)

    Data.gov (United States)

    Department of Housing and Urban Development — The AHS is the largest, regular national housing sample survey in the United States. The U.S. Census Bureau conducts the AHS to obtain up-to-date housing statistics...

  12. 7 CFR Exhibit B to Subpart A of... - Requirements for Modular/Panelized Housing Units

    Science.gov (United States)

    2010-01-01

    ... background information available through the Department of Housing and Urban Development (HUD) for analysis... systems, include supply and return duct layout and location of appropriate diffusers. 8. Electrical plan...

  13. Compensation of equipment housing elements of reactor units with heavy liquid metal coolant vessel temperature deformations

    International Nuclear Information System (INIS)

    Lebedevich, V.; Ahmetshin, M.; Mendes, D.; Kaveshnikov, S.; Vinogradov, A.

    2015-01-01

    In Russia a lot of different versions of fast reactors (FRs) are investigated and one of these is FR cooled by liquid lead and liquid lead-bismuth alloy. In this poster we are interested by FR with concrete vessel; its components are placed in cavities inside the vessel, and connected by a channel system. During the installation the equipment components are placed in several equipment housings. Between these housings there are cavities with coolant. The alignment of the housings should be provided. It can be broken by irregular concrete vessel heating during FR starting or other transition regimes. Our goal is to suggest a list of designing steps to compensate temperature deformations of equipment housing elements. A simplified model of equipment housing was suggested. It consists of two cylinders - tunnels in the concrete vessel, separated by a cavity filled by coolant and inert gas. The bottom part was considered as heated to 420 C. degrees while in the top part temperature decreased to 45 C. degrees (on the concrete surface). According to this data, results show that temperature gradient leads to a concrete layer dislocation of about 12.5 mm, which can lead to damage and breaking alignment. We propose the following solution to compensate for temperature deformation: -) to chisel out part of the upper top of the insulating concrete; -) to install an adequate misalignment of equipment housing elements preliminary; and -) to use a torsion system like a piston-type device for providing additional strength in order to compensate deformation and vibrations

  14. [Application of a stand-alone interbody fusion cage based on a novel porous TiO2/glass composite. I. Implantation in the sheep cervical spine and radiological evaluation].

    Science.gov (United States)

    Korinth, M C; Hero, T; Mahnken, A H; Ragoss, C; Scherer, K

    2004-12-01

    Animals are becoming more and more common as in vitro and in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examination human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO/glass composite (Ecopore) or polymethyl-methacrylate (PMMA) after discectomy. First experience with the use of the new material and its influence on the primary stability after in vitro application were gained. After fusion of 10 sheep cervical spines in the levels C2/3 and C4/5 in each case with PMMA and with an Ecopore-cage, radiologic as well as computertomographic examinations were performed postoperatively and every 4 weeks during the following 2 and 4 months, respectively. Apart from establishing our animal model, we analysed the radiological changes and the degree of bony fusion of the operated segments during the course. In addition we performed measurements of the corresponding disc space heights (DSH) and intervertebral angles (IVA) for comparison among each other, during the course and with the initial values. Immediately after placement of both implants in the disc spaces the mean DSH and IVA increased (34.8% and 53.9%, respectively). During the following months DSH decreased to a greater extent in the Ecopore-segments than in the PMMA-segments, even to a value below the initial value (p>0.05). Similarly, the IVA decreased in both groups in the postoperative time lapse, but more distinct in the Ecopore-segments (pmodel of the sheep cervical spine. Distinct radiological changes regarding evident subsidence and detectable fusion of the segments, operated on with the new biomaterial, were seen. We demonstrated the

  15. STAND-ALONE WIND ENERGY CONVERSION SYSTEM WITH MAXIMUM POWER TRANSFER CONTROL SISTEMA AISLADO DE CONVERSIÓN EÓLICA CON CONTROL DE MÁXIMA TRANSFERENCIA DE POTENCIA

    Directory of Open Access Journals (Sweden)

    Miguel López

    2009-12-01

    Full Text Available A controlled wind generation system for a stand alone application is presented in this paper. A cascaded step-up/step-down power electronic converters topology is proposed to control the wind power system in the whole wind speed range. For the low wind speed range, the control strategy is aimed to follow the wind turbine’s maximal power coefficient by adjusting the generator’s rotational speed. For high wind speeds, the system power regulation is also made by controlling the generator speed. This control is made by the DC/DC power electronic converter, which modifies its input voltage, changing the machine voltage and consequently varying the generator’s rotor speed. The proposed system is validated by computer simulation. The proposed control system shows a good performance for its application in autonomous wind energy systems.Un sistema de generación eólica para una aplicación aislada es presentado en este artículo. Una topología de convertidores electrónicos de potencia elevador y reductor conectados en cascada es propuesta para controlar la producción eólica en todo el rango de velocidades del viento. Para el rango de vientos suaves, la estrategia de control permite seguir el máximo coeficiente de potencia de turbina eólica mediante el ajuste de la velocidad de rotación del generador. En el rango de vientos fuertes, la regulación de la potencia del sistema se hace igualmente por control de la velocidad de giro del generador. La acción de control es realizada mediante el convertidor DC/DC de potencia el cual modifica su tensión de entrada, cambiando así la tensión en los terminales de la máquina y por consecuencia variando la velocidad de rotación del generador. El sistema propuesto es validado mediante simulación por computador. Los resultados muestran que el sistema de control propuesto actúa de buena manera para su aplicación en sistemas autónomos de generación eólica.

  16. Stand-alone photovoltaic system: study of a modular concept with distributed communication and control units; Systeme photovoltaique autonome: etude d'une structure modulaire a gestion repartie

    Energy Technology Data Exchange (ETDEWEB)

    Neusser, A.

    2004-09-15

    This thesis concerns an innovative photovoltaic system concept, which is modular am where the standardisation of all of the components is possible. Lead-acid batteries tare used to store the energy. The main objective of this project is the improvement of the battery management process in the system. As the batteries are the weak point of the system, a new battery charger is developed aiming at a longer life-span and a homogeneous ageing rate for all of them. This charger permits energy exchanges, which are co-ordinated by a communication system. We use a DC/DC converter as power electronics for battery charging. PSpice simulations and tests verify its performance. Simulations with Matlab Simulink show the auto-equalization tendency of the chosen battery management method. In addition, an experimentation under real conditions validates the beneficial effect on the state of health of the batteries. (author)

  17. Assisted Housing - Multifamily Properties - Assisted

    Data.gov (United States)

    Department of Housing and Urban Development — HUD's Multifamily Housing property portfolio consist primarily of rental housing properties with five or more dwelling units such as apartments or town houses, but...

  18. Alternative route of process modification for biofuel production by embedding the Fischer–Tropsch plant in existing stand-alone power plant (10 MW) based on biomass gasification – Part I: A conceptual modeling and simulation approach (a case study in Thailand)

    International Nuclear Information System (INIS)

    Hunpinyo, Piyapong; Cheali, Peam; Narataruksa, Phavanee; Tungkamani, Sabaithip; Chollacoop, Nuwong

    2014-01-01

    Graphical abstract: SynBiofuel production through existing gasification plants in Thailand, using waste agricultural biomass as raw material, was studied. The process design was initiated conceptually in the areas of gas phase reaction system via Fischer-Tropsch (FT) synthesis. The development of FT configurations on syngas conversion to transportation fuels (e.g., diesel range) was investigated. In order to develop a techno-economic assessment, the three different capacities corresponding to 1 MW, 2 MW and 3 MW based on thermal input of syngas were evaluated. Once-through FT concept was proposed in which the unconverted syngas was combusted with air in an externally fired gas turbine (EFGT) to produce surplus electricity. The results of process simulation were discussed open-mindedly including the overall plant design and energy efficiency. Preliminary economics, and some site specific situations under which additional capital cost savings on existing infrastructure was realized. - Highlights: • Experimental results were used and integrated with a reactor model for SynBiofuel. • Process simulation with the lumped reaction rate was used to achieve accurate results. • Process simulation was performed using ASPEN Plus to design FT configurations. • Maximum energy FT efficiency was approximately 37%. • Economic potential was computed by ROI and PBP resulting in the attractive solutions. - Abstract: The utilization of syngas shows a highly potential to improve the economic potential of the stand-alone power unit-based gasification plants as well as enhancing the growing demand of transportation fuels. The thermochemical conversion of biomass via gasification to heat and power generations from the earlier study is further enhanced by integrating Fischer–Tropsch (FT) synthesis with the existing gasification pilot scale studied previously. To support the potential and perspectives in major economies due to scaling up in developing countries such as Thailand

  19. 7 CFR 1924.8 - Development work for modular/panelized housing units.

    Science.gov (United States)

    2010-01-01

    ... (exhibit B, attachment 5 of this subpart), stating that the building has been built substantially in..., attachment 5 of this subpart). (d) Responsibility for field inspections will be in accordance with § 1924.9(a... borrower for the complete house in place on the site. Such contracts should provide that payments will be...

  20. DOE ZERH Case Study: United Way of Long Island Housing Development Corporation, Patchogue, NY

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning affordable home in the mixed-humid climate that got HERS 40 without PV, -3 with PV, with 2x4 16: on center walls with R-13.5 dense packed cellulose and 1.5” polyiso rigid; basement with 2.5: polyiso on interior; unvented attic with R-48 ocsf under roof deck; ERV tied to wall hung boiler with hydro coil.

  1. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 (Version 2.1) Catchments Riparian Buffer for the Conterminous United States: 2010 US Census Housing Unit and Population Density

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset represents the population and housing unit density within individual, local NHDPlusV2 catchments and upstream, contributing watersheds riparian buffers...

  2. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 (Version 2.1) Catchments for the Conterminous United States: 2010 US Census Housing Unit and Population Density

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset represents the population and housing unit density within individual, local NHDPlusV2 catchments and upstream, contributing watersheds based on 2010 US...

  3. Study of the efficiency of some water treatment unit that present in houses in Erbil city-Iraq

    Science.gov (United States)

    Toma, Janan. Jabbar.; Hanna, Aveen. Matti.

    2017-09-01

    Many people in Erbil city started more than two decade to put special treatment units in their houses to purified water to become safer for drinking uses. The aim of this study was determine the efficiency of six kind water treatment units which include (two replicate of Crystal Water Purifier, So-Safe Water Filter, R O Water Purifier, Kontec Water Purified and Al-Kawther Purified Water). Water samples were collected in two sites one before and other after treatment unit. Each sample was collect with three replication during May to October-2016. Analyzed for Major cations concentration (calcium, magnesium, sodium and potassium), anions concentration (nitrate and chloride) and hydrogen ion concentration (pH), electrical conductivity (EC), total dissolved solids (TDS), alkalinity and total hardness by using standard methods. The water quality index values for all raw water sample befor and after treatment was good and excellent respectively for drinking purposes. Efficiency of So-Safe Water Filter was 66.32% it means was more efficiency than others special water treatment units while in RO Water Purifier was 27.14%, means less efficiency than other water purifier water under this study. Values for major cations, anions and others chemicals characteristics in the water samples after treatment became lower concentrations than befor treatment, likely an indication that these were removed by treatment. According to guideline of world health organization all of variables except total hardness befor treatment are safe and suitable for drinking purposes.

  4. A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up.

    Science.gov (United States)

    Chen, Yuqiao; Lü, Guohua; Wang, Bing; Li, Lei; Kuang, Lei

    2016-07-01

    To evaluate the clinical efficacy and radiological outcomes of anterior cervical discectomy and fusion (ACDF) using self-locking polyetheretherketone (PEEK) cages for treatment of three-level cervical degenerative spondylopathy. Twenty-eight patients underwent three-level ACDF using self-locking stand-alone PEEK cages (group A), and 26 patients underwent three-level ACDF using cages and plate fixation (group B) were reviewed retrospectively. Clinical efficacy was evaluated by pre- and post-operative Japanese Orthopedic Association (JOA) scores and Neck Disability Index (NDI). The operation time, blood loss, surgical results according to Odom's criteria and post-operative dysphagia status were also recorded. Radiological outcomes including fusion, cervical Cobb's lordosis, fused segment angle, disc height, and cage subsidence were assessed. Clinical outcome measures such as dysphagia and fusion rate and the results of surgery evaluated according to Odom's criteria were not statistically significant (P > 0.05) between groups. The operation time was shorter and blood loss was less in group A (P  0.05). Post-operative cage subsidence, the loss of disc height, cervical lordosis and the fused segment angle were relatively higher in group A than group B (P < 0.05). ACDF using self-locking stand-alone cages showed similar clinical results as compared to ACDF using cages and plate fixation for the treatment of three-level cervical degenerative spondylopathy. However, potential long-term problems such as cage subsidence, loss of cervical lordosis and fused segment angle post-operatively were shown to be associated with patients who underwent ACDF using self-locking stand-alone cages.

  5. 24 CFR 92.258 - Elder cottage housing opportunity (ECHO) units.

    Science.gov (United States)

    2010-04-01

    ... designed to be installed adjacent to existing single-family dwellings. (b) Eligible owners. The owner of a HOME-assisted ECHO unit may be: (1) The owner-occupant of the single-family host property on which the... elderly or disabled family as defined in 24 CFR 5.403 and must also be a low-income family. (d) Applicable...

  6. American Housing Survey (AHS) 2011

    Data.gov (United States)

    Department of Housing and Urban Development — The AHS is the largest, regular national housing sample survey in the United States. The U.S. Census Bureau conducts the AHS to obtain up-to-date housing statistics...

  7. Policy making opportunities in the United States Senate and House of Representatives: an examination of seniority and gridlock

    Science.gov (United States)

    McCurdy, K. M.

    2017-12-01

    A policy arc is traced by a series of election outcomes, and it is the remaining representatives from past elections with their ideological stances and their parliamentary experiences that is predictive of whether public policy positions are sustained, modulated, or abandoned by the legislature. Two unusual legislative elections, the 1974 and 1994 races for the United States House of Representatives, can provide additional understanding and evidence for the necessary and sufficient conditions for policy innovation. Contrasting the magnitude of the House and Senate majorities along with their respective seniority patterns in the subsequent twenty years from these transformative elections shows the differing conditions that produces policy innovation or gridlock. Legislative actions clearly operate on two temporal planes, with consequences for the election that is coming months hence as well as for governance that occurs over years or multiple decades. Elections have policy consequences that are moderated by formal institutional rules and informal norms of behavior. Members of a class of legislators plus their nearest election class neighbors can influence the shape and content of legislation for twenty years. These effects can be reinforced or mitigated by the results from several election outcomes. But the effects of the initial election, Et0 remain noticeable decades later. This pattern is particularly persistent when freshmen in the House of Representatives hold more than 20 percent of seats in the chamber. These traces of seniority are easily disrupted so their persistence is a signal that should not be ignored for policy entrepreneurs and those wishing to influence public policy. Gridlock should thus be seen as indicative of a facies change in public policy that reflects the changes in society being represented in the legislature, not as an end game in the shorter run election cycle. Legislative gridlock is a state in the public policy process that is ridiculed

  8. Scalable single point power extraction for compact mobile and stand-alone solar harvesting power sources based on fully printed organic photovoltaic modules and efficient high voltage DC/DC conversion

    DEFF Research Database (Denmark)

    Garcia Valverde, Rafael; Villarejo, José A.; Hösel, Markus

    2015-01-01

    (AM1.5G, 1000 W m−2). As a demonstration we present a scalable fully integrated and compact power unit for mobile applications comprising solar energy harvesting OPV modules, power conversion and storage. Applications possible include electrical charging of mobile devices, illumination using LED lamps...

  9. A Study Identifying and Validating Competencies Needed for Mid-Managers That Work in Housing and Residence Life at Colleges and Universities in the United States of America

    Science.gov (United States)

    Morrison, Hassel Andre

    2016-01-01

    The researcher identified a gap in the knowledge of competencies needed for midmanagers that work in housing and residence life at the southeast colleges and universities in the United States. The purpose of this study was to identify and develop a consensus on competencies needed by mid-managers. The review of the literature describes and…

  10. Domestic Consequences of United States Population Change. Report Prepared by the Select Committee on Population, U.S. House of Representatives, Ninety-Fifth Congress, Second Session.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. House Select Committee on Population.

    The report, prepared by the Select Committee on Population of the United States House of Representatives, discusses the consequences of the changing age composition and geographical distribution of the population. The committee recommends that the government needs to anticipate these changes in order to develop a policy in response to the problems…

  11. The solar house of CRESESB: seven years of success

    Energy Technology Data Exchange (ETDEWEB)

    Galdino, Marco Antonio; Souza, Hamilton Moss de, E-mail: marcoag@cepel.br

    2005-07-01

    The solar house is located in the facilities of CEPEL - Centro de Pesquisas de Energia Eletrica (Electric Power Research Centre) at Fundao Island, Rio de Janeiro, Brazil. It is powered by a stand-alone PV system and is operated by CRESESB - Centro de Referencia para Energia Solar e Eolica Sergio de Salvo Brito (Reference Centre for Solar and Wind Energy Sergio de Salvo Brito) as a demonstration centre. The solar house was built in 1997, and during seven years of operation it received about 9.000 visitors (up to middle 2004). The present paper shares some aspects of the experience gained with the solar house, including technical details of the systems installed, the experience in operation and maintenance, and the divulgation and training of personnel so far obtained. (author)

  12. Qualitative overview of living conditions and health status of seasonal (mobile/temporary agricultural workers in two housing units

    Directory of Open Access Journals (Sweden)

    Mehmet Kaya

    2015-08-01

    Full Text Available Objective: In this research we aimed to determine the status of seasonal agricultural workers located in two housing units in terms of living, working and health conditions.  Methods: This is a descriptive study using qualitative methods: in-depth interviews and in situ observations. It took place in provinces of Adana and Mersin located in the Çukurova region and the Şanlıurfa province. A common feature of these provinces is their high density of seasonal agricultural workers. Our field work was performed by going to places where seasonal agricultural workers live and work. The research was conducted during the dates of March 2014 and August 2014. Snowball sampling methods was used in this research. Data were collected by interviews with 26 seasonal agricultural workers who were older than 15. Results: Seasonal agricultural workers were working without social insurance, safe transportation facilities, or guarantee of employment and without any worker’s health and safety precautions being taken by the employees. Accommodation units lacked fundamental structural and safety features. Seasonal agricultural workers were faced with social alienation and could not access the basic health services such as vaccination, antenatal follow-up, reproductive health or outpatient services. Also, their diet was unbalanced and insufficient. Children could not take the benefit sufficiently from education and were employed in agricultural work. In addition to their agricultural work, women also were exploited in their domestic life. Conclusion: Seasonal agricultural workers were in an aggrieved position concerning topics such as transportation, accommodation, wages and social insurance. To eliminate these conditions, the opinion of agricultural middlemen, seasonal agricultural workers and employees should be taken into account with the financial support of local authorities under the scope of the law. 

  13. A before and after study of medical students' and house staff members' knowledge of ACOVE quality of pharmacologic care standards on an acute care for elders unit.

    Science.gov (United States)

    Jellinek, Samantha P; Cohen, Victor; Nelson, Marcia; Likourezos, Antonios; Goldman, William; Paris, Barbara

    2008-06-01

    The Assessing Care of Vulnerable Elders (ACOVE) comprehensive set of quality assessment tools for ill older persons is a standard designed to measure overall care delivered to vulnerable elders (ie, those aged > or =65 years) at the level of a health care system or plan. The goal of this research was to quantify the pretest and posttest results of medical students and house staff participating in a pharmacotherapist-led educational intervention that focused on the ACOVE quality of pharmacologic care standards. This was a before and after study assessing the knowledge ofACOVE standards following exposure to an educational intervention led by a pharmacotherapist. It was conducted at the 29-bed Acute Care for Elders (ACE) unit of Maimonides Medical Center, a 705-bed, independent teaching hospital located in Brooklyn, New York. Participants included all medical students and house staff completing a rotation on the ACE unit from August 2004 through May 2005 who completed both the pre-and posttests. A pharmacotherapist provided a 1-hour active learning session reviewing the evidence supporting the quality indicators and reviewed case-based questions with the medical students and house staff. Educational interventions also occurred daily through pharmacotherapeutic consultations and during work rounds. Medical students and house staff were administered the same 15-question, patient-specific, case-based, multiple-choice pre-and posttest to assess knowledge of the standards before and after receiving the intervention. A total of 54 medical students and house staff (median age, 28.58 years; 40 men, 14 women) completed the study. Significantly higher median scores were achieved on the multiple-choice test after the intervention than before (median scores, 14/15 [93.3%] vs 12/15 [80.0%], respectively; P = 0.001). A pharmacotherapist-led educational intervention improved the scores of medical students and house staff on a test evaluating knowledge of evidence

  14. 24 CFR 982.606 - Congregate housing: Who may reside in congregate housing.

    Science.gov (United States)

    2010-04-01

    ... Special Housing Types Congregate Housing § 982.606 Congregate housing: Who may reside in congregate housing. (a) An elderly person or a person with disabilities may reside in a congregate housing unit. (b... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Congregate housing: Who may reside...

  15. Energy house - dream house

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    An energy house a prefabricated house with an extensive minimization of heat losses, is air-conditioned by means of a combined heating system consisting of hot water cycle and recirculating heating. The energy system is trivalent: wind power, solar energy with heat pumps and normal oil heating.

  16. Comparison between In-house developed and Diamond commercial software for patient specific independent monitor unit calculation and verification with heterogeneity corrections.

    Science.gov (United States)

    Kuppusamy, Vijayalakshmi; Nagarajan, Vivekanandan; Jeevanandam, Prakash; Murugan, Lavanya

    2016-02-01

    The study was aimed to compare two different monitor unit (MU) or dose verification software in volumetric modulated arc therapy (VMAT) using modified Clarkson's integration technique for 6 MV photons beams. In-house Excel Spreadsheet based monitor unit verification calculation (MUVC) program and PTW's DIAMOND secondary check software (SCS), version-6 were used as a secondary check to verify the monitor unit (MU) or dose calculated by treatment planning system (TPS). In this study 180 patients were grouped into 61 head and neck, 39 thorax and 80 pelvic sites. Verification plans are created using PTW OCTAVIUS-4D phantom and also measured using 729 detector chamber and array with isocentre as the suitable point of measurement for each field. In the analysis of 154 clinically approved VMAT plans with isocentre at a region above -350 HU, using heterogeneity corrections, In-house Spreadsheet based MUVC program and Diamond SCS showed good agreement TPS. The overall percentage average deviations for all sites were (-0.93% + 1.59%) and (1.37% + 2.72%) for In-house Excel Spreadsheet based MUVC program and Diamond SCS respectively. For 26 clinically approved VMAT plans with isocentre at a region below -350 HU showed higher variations for both In-house Spreadsheet based MUVC program and Diamond SCS. It can be concluded that for patient specific quality assurance (QA), the In-house Excel Spreadsheet based MUVC program and Diamond SCS can be used as a simple and fast accompanying to measurement based verification for plans with isocentre at a region above -350 HU. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. HIA 2016 DOE Zero Energy Ready Home Case Study: United Way of Long Island, United Veterans, Beacon House, Deer Park, NY

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2016-09-01

    Case study of a DOE 2016 Housing Innovation Award winning affordable home in the mixed-humid climate that met the DOE Zero Energy Ready Home criteria and achieved a HERS 32 without PV or HERS 9 with PV.

  18. Autonomous houses. Autonomous house

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, S. (Tokai University, Tokyo (Japan). Faculty of Engineering)

    1991-09-30

    Self-sufficiency type houses are outlined. On condition that people gain a certain amount of income in relation with the society, they self-suffice under the given environment, allowing themselves to accept a minimum of industrial products with small environmental load. Ordinary supply from outside of fossil energy and materials which depend on it is minimized. Types are classified into three: energy, energy materials and perfect self-sufficiency. A study project for environment symbiotic houses is progressing which is planned by the Ministry of Construction and Institute of Building Energy Conservation and is invested by a private company. Its target is making a house for halving an environmental load by CO{sub 2}, for the purpose of creating the environment symbiotic house which is nice to and in harmony with the global environment and human beings. As a part of the studies on energy-saving and resource conservation on houses, introduced is a plan of an autonomous house at Izu-Atagawa. The passive method and high thermal-insulation are used for air conditioning, and hot spring water for hot water supply. Electric power is generated by hydroelectric power generation using mountain streams and by solar cells. Staple food is purchased, while subsidiary food is sufficed. 17 refs., 4 figs., 1 tab.

  19. Performance evaluation of stand alone hybrid PV-wind generator

    International Nuclear Information System (INIS)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-01-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand

  20. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  1. Algal Hydrogen Production -- Stand Alone or Integrated System?

    Energy Technology Data Exchange (ETDEWEB)

    Ghirardi, Maria L.; Maness, Pin Ching; Kosourovo, Sergey

    2016-01-01

    Photosynthetic bacteria and green algae photoproduce H2. but do so utilizing different catalysts and substrates. Green algae use reductant generate mostly by water oxidation to catalyze the reduction of protons to H2 gas, while photosynthetic bacteria catalyze H2 production from organic acids using the nitrogenase enzyme. Moreover, these two organisms utilize different regions of the solar spectrum to perform photosynthesis: green algae's light harvesting antenna is comprised of chlorophyll molecules that absorb mostly blue and red light; photosynthetic bacteria harvest blue and far-red light through their light-harvesting pigments to run its non-oxygenic photosynthetic reactions. There is thus an opportunity to increase the range of solar spectrum used to photoproduce H2 by combining the light-harvesting and catalytic properties of these two organisms in a single process. In the current manuscript, we describe an experimental system that validates this hypothesis and demonstrates quantitatively the advantages of a two organism process for production of higher amounts of H2 and thus achieving solar light conversion efficiencies.

  2. Deterrents on the Over Utilisation of Stand Alone Photovoltaic (PV ...

    African Journals Online (AJOL)

    At inception of the programme, systems were either undersized, or over utilised as clients did not reveal their usage needs in an attempt to reduce costs. This resulted in battery failures and other system breakdowns. The NPVREP categorised systems in order to alleviate the problem of under sizing and/or over utilization of ...

  3. Basic Stand Alone Medicare Claims Public Use Files

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS is committed to increasing access to its Medicare claims data through the release of de-identified data files available for public use. They contain...

  4. The yeast stands alone: the future of protein biologic production.

    Science.gov (United States)

    Love, Kerry R; Dalvie, Neil C; Love, J Christopher

    2017-12-22

    Yeasts are promising alternative hosts for the manufacturing of recombinant protein therapeutics because they simply and efficiently meet needs for both platform and small-market drugs. Fast accumulation of biomass and low-cost media reduce the cost-of-goods when using yeast, which in turn can enable agile, small-volume manufacturing facilities. Small, tractable yeast genomes are amenable to rapid process development, facilitating strain and product quality by design. Specifically, Pichia pastoris is becoming a widely accepted yeast for biopharmaceutical manufacturing in much of the world owing to a clean secreted product and the rapidly expanding understanding of its cell biology as a host organism. We advocate for a near term partnership spanning industry and academia to promote open source, timely development of yeast hosts. Copyright © 2017. Published by Elsevier Ltd.

  5. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  6. Basic Stand Alone Medicare Prescription Drug Events PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This is a Public Use File for Prescription Drug Events drawn from the 2008 Beneficiary Summary File of Medicare beneficiaries enrolled during the calendar year 2008,...

  7. PV-Battery Sizing for Stand-Alone Lighting Applications

    OpenAIRE

    Herteleer, Bert; Cappelle, Jan; Appels, Reinhart; Lefevre, Buvana; Driesen, Johan; Catthoor, Francky

    2013-01-01

    This paper presents a follow-up and addition to a system sizing spreadsheet, detailed in [An autonomous photovoltaic system sizing program for office applications in Africa], with a focus on sizing or verifying the employability of an off-grid PV-battery system for night lighting. A dimensionless criterion, the Battery Usable Fraction UF_batt is defined, which aids both the calculations of systems and allows an approximate comparison of batteries, regardless of the employed battery chemistry....

  8. Constraining lidar stand-alone retrievals with lunar photometry measurements

    Science.gov (United States)

    Ortiz-Amezcua, Pablo; Luis Guerrero-Rascado, Juan; Antonio Benavent-Oltra, Jose; Román, Roberto; Böckmann, Christine; Alados-Arboledas, Lucas

    2018-04-01

    This study combines atmospheric optical information measured with lidar and nocturnal photometers in order to find configurations that allow for the retrieval of particle microphysical properties without "3+2" lidar setups. It has been carried out using data measured at the EARLINET Granada station during the experimental campaign SLOPE in the framework of ACTRIS-2 project.

  9. The impact of diminished housing wealth on health in the United States: evidence from the Great Recession.

    Science.gov (United States)

    Yilmazer, Tansel; Babiarz, Patryk; Liu, Fen

    2015-04-01

    The sharp decline in home values in many industrialized and developing countries was one of the most evident facets of the global economic recession of 2008. Using data from the Panel Study of Income Dynamics (PSID) for 2007-2011, this study examines how the decline in housing wealth affected the psychological and physical health and health-related behaviors of 4007 U.S. households who were homeowners in 2007. We focus on two mechanisms that could account for how the drop in housing wealth affects health: increase in stress and negative changes in health-related behaviors. Controlling for the changes in non-housing wealth and employment status during the recession, the decline in housing wealth is associated with a small but statistically significant increase in psychological distress. Psychological health deteriorates more as the housing wealth relative to total wealth decreases. Finally, homeowners who have difficulties with mortgage payments report substantial increases in psychological distress and have higher rates of depression. These findings, combined with limited evidence of the change in health-related behaviors, suggest that the increase in stress is the main cause of the adverse health outcomes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Unit costs for house spraying and bednet impregnation with residual insecticides in Colombia: a management tool for the control of vector-borne disease.

    Science.gov (United States)

    Kroeger, A; Ayala, C; Medina Lara, A

    2002-06-01

    A study of unit costs and cost components of two malaria-control strategies (house spraying and bednet impregnation with residual insecticides) was undertaken in 11 malaria-endemic states (departamentos) of Colombia, using data provided by control staff on self-administered questionnaires. The accuracy of the data was verified by personal visits, telephone conversations and complementary information from 10 other states. Allthe financial-cost components of the malaria-control operations carried out in the previous 6 months and the results of the control operations themselves (including the numbers of houses sprayed and numbers of bednets impregnated/day) were recorded. The information was stratified according to whether the target communities were 'near' or 'far away' from an operational base, the far-away communities being those that needed overnight stays by the control staff. The main variables analysed were unit costs/house treated, and annual cost/person protected. The results show that house spraying was generally more expensive for the health services than bednet impregnation. This is particularly the case in 'nearby' communities, where most of those at-risk live. In such communities, spraying one house was 7.2 times more expensive than impregnating one bednet. Even if only those sleeping under an impregnated net were assumed to be protected, the unit costs/person protected in a 'nearby' community were twice as high for house spraying than for bednet impregnation. In 'nearby' communities, where technicians could return to the operational base each evening, insecticides made up 80% of the total spraying costs and 42% of the costs of bednet impregnation. In 'far-away' communities, however, salaries and 'per diems' were the most important cost components, representing, respectively, 23% and 22% of the costs of spraying, and 34% plus 27% of the costs of impregnation. Insecticide wastage and non-use of discounts on insecticide prices (available through the

  11. Delivery Strategies to Enhance the Sustainability of Training: Lessons from the Food and Agriculture Organization of the United Nations

    Science.gov (United States)

    de Rosa, Cecilia; Nadeau, Andrew; Hernandez, Emilio; Kafeero, Fred; Zahiga, Jacques

    2016-01-01

    The Food and Agriculture Organization of the United Nations (FAO) utilizes training as a major component of the support it provides to its member countries in Africa. In the past, stand-alone training events targeting individual actors were the norm. However, an external evaluation indicated that this type of training scores low in terms of…

  12. Public Housing Agency (PHA) Inventory

    Data.gov (United States)

    Department of Housing and Urban Development — The dataset contains current data on low rent and Section 8 units in PHA's administered by HUD. The Section 8 Rental Voucher Program increases affordable housing...

  13. Civil rights as determinants of public health and racial and ethnic health equity: Health care, education, employment, and housing in the United States.

    Science.gov (United States)

    Hahn, R A; Truman, B I; Williams, D R

    2018-04-01

    This essay examines how civil rights and their implementation have affected and continue to affect the health of racial and ethnic minority populations in the United States. Civil rights are characterized as social determinants of health. A brief review of US history indicates that, particularly for Blacks, Hispanics, and American Indians, the longstanding lack of civil rights is linked with persistent health inequities. Civil rights history since 1950 is explored in four domains-health care, education, employment, and housing. The first three domains show substantial benefits when civil rights are enforced. Discrimination and segregation in housing persist because anti-discrimination civil rights laws have not been well enforced. Enforcement is an essential component for the success of civil rights law. Civil rights and their enforcement may be considered a powerful arena for public health theorizing, research, policy, and action.

  14. Convergence of metropolitan house prices in South Africa: a re-examination using efficient unit root tests

    CSIR Research Space (South Africa)

    Das, Sonali

    2010-01-01

    Full Text Available This paper analyzes whether the Law of One Price (LOOP) holds in the housing market of five metropolitan areas of South Africa, namely Cape Town, Durban, Greater Johannesburg, Port Elizabeth/Uitenhage and Pretoria. The authors test the existence...

  15. Views of United States Physicians and Members of the American Medical Association House of Delegates on Physician-assisted Suicide.

    Science.gov (United States)

    Whitney, Simon N.; Brown, Byron W.; Brody, Howard; Alcser, Kirsten H.; Bachman, Jerald G.; Greely, Henry T.

    2001-01-01

    Ascertained the views of physicians and physician leaders toward legalization of physician-assisted suicide. Results indicated members of AMA House of Delegates strongly oppose physician-assisted suicide, but rank-and-file physicians show no consensus either for or against its legalization. Although the debate is adversarial, most physicians are…

  16. Modelling process integration and its management – case of a public housing delivery organization in United Arab Emirates

    Directory of Open Access Journals (Sweden)

    Venkatachalam Senthilkumar

    2017-01-01

    Full Text Available Huge volume of project information are generated during the life cycle of an AEC projects. These project information are categorized in to technical and administrative information and managed through appropriate processes. There are many tools such as Document Management Systems, Building Information Modeling (BIM available to manage and integrate the technical information. However, the administrative information and its related processes such as the payment, status, authorization, approval etc. are not effectively managed. The current study aims to explore the administrative information management process of a local housing delivery public agency. This agency manages more than 2000 housing projects at any time of a year. The administrative processesare characterized withdelivery inconsistencies among various project participants. Though there are many commercially available process management systems, there exist limitations on the customization of the modules/ systems. Hence there is a need to develop an information management system which can integrates and manage these housing projects processes effectively. This requires the modeling of administrative processes and its interfaces among the various stakeholder processes. Hence this study aims to model the administrative processes and its related information during the life cycle of the project using IDEF0 and IDEF1X modeling. The captured processes and information interfaces are analyzed and appropriate process integration is suggested to avoid the delay in their project delivery processes. Further, the resultant model can be used for effectively managing the housing delivery projects.

  17. Perceptions of 24/7 In-house Attending Coverage on Fellow Education and Autonomy in a Pediatric Cardiothoracic Intensive Care Unit.

    Science.gov (United States)

    Owens, Sonal T; Owens, Gabe E; Rajput, Shaili H; Charpie, John R; Kidwell, Kelley M; Mullan, Patricia B

    2015-01-01

    The 24/7 in-house attending coverage is emerging as the standard of care in intensive care units. Implementation costs, workforce feasibility, and patient outcomes resulting from changes in physician staffing are widely debated topics. Understanding the impact of staffing models on the learning environment for medical trainees and faculty is equally warranted, particularly with respect to trainee education and autonomy. This study aims to elicit the perceptions of pediatric cardiology fellows and attendings toward 24/7 in-house attending coverage and its effect on fellow education and autonomy. We surveyed pediatric cardiology fellows and attendings practicing in the pediatric cardiothoracic intensive care unit (PCTU) of a large, university-affiliated medical center, using structured Likert response items and open-ended questions, prior to and following the transition to 24/7 in-house attending coverage. All (100%) trainees and faculty completed all surveys. Both prior to and following transition to 24/7 in-house attending coverage, all fellows, and the majority of attendings agreed that the overnight call experience benefited fellow education. At baseline, trainees identified limited circumstances in which on-site attending coverage would be critical. Preimplementation concerns that 24/7 in-house attending coverage would negatively affect the education of fellows were not reflected following actual implementation of the new staffing policy. However, based upon open-ended questions, fellow autonomy was affected by the new paradigm, with fellows and attendings reporting decreased "appropriateness" of autonomy after implementation. Our prospective study, showing initial concerns about limiting the learning environment in transitioning to 24/7 in-house attending coverage did not result in diminished perceptions of the educational experience for our fellows but revealed an expected decrease in fellow autonomy. The study indirectly facilitated open discussions about

  18. Housing, income support and mental health: Points of disconnection

    Directory of Open Access Journals (Sweden)

    Csiernik Rick

    2007-12-01

    Full Text Available Abstract There exists a disconnection between evolving policies in the policy arenas of mental health, housing, and income support in Canada. One of the complexities associated with analysing the intersection of these policies is that federal, provincial, and municipal level policies are involved. Canada is one of the few developed countries without a national mental health policy and because of the federal policy reforms of the 1970s, the provincial governments now oversee the process of deinstitutionalization from the hospital to the community level. During this same period the availability of affordable housing has decreased as responsibility for social housing has been transfered from the federal government to the provincial and/or municipal levels of government. Canada also stands alone in terms of being a developed nation without national housing policy instead what is considered "affordable" housing is partially dependant upon individuals' personal economic resources. As well, over the past decade rates of income supports have also been reduced. Psychiatric survivors have long been identified as being at risk for homelessness, with the disconnection existing between housing, income and mental health policies and the lack of a national policy in any of these policies areas further contributing to this risk.

  19. Modern Housing Retrofit: Assessment of Upgrade Packages to EnerPHit Standard for 1940–1960 State Houses in Auckland

    Directory of Open Access Journals (Sweden)

    Paola Leardini

    2015-03-01

    Full Text Available New Zealand state housing includes a significant portion of problematic buildings constructed after the public housing scheme launched in 1936. Most of these houses are still uninsulated, thus, cold, draughty, mouldy, and progressively decaying; however, as they are fundamental elements of the country’s culture, society, and environment, and are built with good quality materials and sound construction, they are suitable candidates for effective energy upgrades. This paper presents findings of a study on problems and opportunities of retrofitting the state houses built between 1940 and 1960 in the Auckland region. It advocates strategic national policies and initiatives for retrofitting, based on more challenging performance thresholds. The research defines and virtually implements an incremental intervention strategy including different retrofit packages for a typical 1950s stand-alone house. Indoor and outdoor environmental parameters were monitored over a year, and data used to establish a base case for thermal simulation. The upgrade packages were then modelled to assess their impact on the house’s thermal performance, comparing heating requirements and comfort of various insulation and ventilation options. The paper reports on effective ways of preserving the integrity of such a house, while improving its thermal performance to the EnerPHit standard, and discusses the benefits of introducing this holistic approach into New Zealand retrofit practice.

  20. Housing culture

    DEFF Research Database (Denmark)

    Roesdahl, Else; Scholkmann, Barbara

    2007-01-01

    On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies.......On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies....

  1. A variation of the housing unit method for estimating the age and gender distribution of small, rural areas: A case study of the local expert procedure

    International Nuclear Information System (INIS)

    Carlson, J.F.; Roe, L.K.; Williams, C.A.; Swanson, D.A.

    1993-01-01

    This paper describes the methodologies used in the development of a demographic data base established in support of the Yucca Mountain Site Characterization Project Radiological Monitoring Plan (RadMP). It also examines the suitability of a survey-based procedure for estimating population in small, rural areas. The procedure is a variation of the Housing Unit Method. It employs the use of local experts enlisted to provide information about the demographic characteristics of households randomly selected from residential units sample frames developed from utility records. The procedure is nonintrusive and less costly than traditional survey data collection efforts. Because the procedure is based on random sampling, confidence intervals can be constructed around the population estimated by the technique. The results of a case study are provided in which the total population, and age and gender of the population, is estimated for three unincorporated communities in rural, southern Nevada

  2. Data acquisition and meter unit based in wifi communication protocol

    Directory of Open Access Journals (Sweden)

    Gerardo Cázarez Ayala

    2012-05-01

    Full Text Available Without doubt, the competitive fast rhythm of the industries is one of the main causes helped bring to the accelerated growth of the electronic technology and the communication. The need to develop new products with a best quality, cheaper and faster as assure and increase the quality of the products in the international markets, requires of new technologies to the metering, monitoring and control of their production processes, of which finality is to improve the processes to guaranteed their products in the market in the less time possible, the best quality and low cost for the final consumer. This work is based in the design and implementation of a Wireless Data Acquisition Unit based in WiFi protocol, which is oriented to meter, monitoring and the control of processes in the industry, commercial and the home automation applications, using one of the wirelessprotocols with the biggest acceptance in the market, with the main objective of to take advantage of the installed physical infrastructure in the place of the application, like industry, company or house. The Unit is based in the RN-131G, a Roving Network company module, which is able to work in stand-alone mode with ultralow power consummation and supporting the IEEE 802.11b/g protocols, in which is possible to achieve transfer rates of up to 11 Mbps and 54 Mbps in /b & /g specifications respectively. Whit this unit is possible to meter up to 5 analogs signals with 14 bits precision and has include a temperature and relative humidity sensors. This unit can meter two digital signals and act mean two digitals outputs, and gas include an USB port for communication and programming tasks.

  3. Assisted Housing - Low Income Housing Tax Credit Properties - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The Low-Income Housing Tax Credit (LIHTC) is the primary Federal program for creating affordable housing in the United States. The LIHTC database, created by HUD and...

  4. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...... on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C...

  5. 7 CFR 3560.104 - Fair housing.

    Science.gov (United States)

    2010-01-01

    ... DIRECT MULTI-FAMILY HOUSING LOANS AND GRANTS Borrower Management and Operations Responsibilities § 3560... Housing Marketing Plan. (1) Borrowers with housing projects that have four or more rental units must prepare and maintain an Affirmative Fair Housing Marketing Plan (AFHMP) as defined in 24 CFR part 200...

  6. House of Generations

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2017-01-01

    only the benefits of living close to the family. The Aarhus Municipality project "House of Generations" is a vision for creating a framework for relationships across all generations, for meaningful encounters and for rewarding neighbourliness. Three of Aarhus Municipality's magistrate departments...... participate in the project: Health and Care, Children and Youth, and Social Conditions and Employment. A public housing association that provides student dorms also participates in the project. The physical framework will be a building with a total area of approx. 25,000 m², located at Pier 4, at Aarhus......' harbour areas. The building will be a multi-generational house comprising a mixture of flexible public housing units for students, the elderly and residents who require care (elderly disabled people and people with acquired brain injuries). The building will be connected with common areas located in close...

  7. Clay Houses

    Science.gov (United States)

    Pedro, Cathy

    2011-01-01

    In this article, the author describes a project designed for fourth-graders that involves making clay relief sculptures of houses. Knowing the clay houses will become a family heirloom makes this lesson even more worth the time. It takes three classes to plan and form the clay, and another two to underglaze and glaze the final products.

  8. Environmental Health Disparities in Housing

    Science.gov (United States)

    2011-01-01

    The physical infrastructure and housing make human interaction possible and provide shelter. How well that infrastructure performs and which groups it serves have important implications for social equity and health. Populations in inadequate housing are more likely to have environmental diseases and injuries. Substantial disparities in housing have remained largely unchanged. Approximately 2.6 million (7.5%) non-Hispanic Blacks and 5.9 million Whites (2.8%) live in substandard housing. Segregation, lack of housing mobility, and homelessness are all associated with adverse health outcomes. Yet the experience with childhood lead poisoning in the United States has shown that housing-related disparities can be reduced. Effective interventions should be implemented to reduce environmental health disparities related to housing. PMID:21551378

  9. Pathology of mass housing projects in Iran (Mehr Housing Plan ...

    African Journals Online (AJOL)

    Mass housing in construction industry is known as projects that mass production methods are used to construct residential units in it. Mass housing is a model of construction that has high economic, technical and managerial feasibility and should optimize three areas of quality, time and cost. But it should be noted that in ...

  10. Tech House

    Science.gov (United States)

    1978-01-01

    The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, loatedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

  11. CDBG Housing Activity

    Data.gov (United States)

    Department of Housing and Urban Development — CDBG activity related to housing, including multifamily rehab, housing services, code enforcement, operation and repair of foreclosed property and public housing...

  12. White House

    Science.gov (United States)

    ... content Jump to navigation the WHITE HOUSE President Donald J. Trump Get in Touch Home Briefing Room From the ... For All Americans The Administration The Administration President Donald J. Trump Vice President Mike Pence First Lady Melania Trump ...

  13. Conformal house

    DEFF Research Database (Denmark)

    Ryttov, Thomas Aaby; Sannino, Francesco

    2010-01-01

    fixed point. As a consistency check we recover the previously investigated bounds of the conformal windows when restricting to a single matter representation. The earlier conformal windows can be imagined to be part now of the new conformal house. We predict the nonperturbative anomalous dimensions...... at the infrared fixed points. We further investigate the effects of adding mass terms to the condensates on the conformal house chiral dynamics and construct the simplest instanton induced effective Lagrangian terms...

  14. Housing and child health.

    Science.gov (United States)

    Weitzman, Michael; Baten, Ahmareen; Rosenthal, David G; Hoshino, Risa; Tohn, Ellen; Jacobs, David E

    2013-09-01

    The connection between housing and health is well established. Physical, chemical, and biological aspects of the child's home, such as cleanliness, moisture, pests, noise, accessibility, injury risks, and other forms of housing environmental quality, all have the potential to influence multiple aspects of the health and development of children. Basic sanitation, reduced household crowding, other improvements in housing and expanded, and improved housing regulations have led to advances in children's health. For example, lead poisoning prevention policies have profoundly reduced childhood lead exposure in the United States. This and many other successes highlight the health benefits for families, particularly children, by targeting interventions that reduce or eliminate harmful exposures in the home. Additionally, parental mental health problems, food insecurity, domestic violence, and the presence of guns in children's homes all are largely experienced by children in their homes, which are not as yet considered part of the Healthy Homes agenda. There is a large movement and now a regulatory structure being put in place for healthy housing, which is becoming closely wedded with environmental health, public health, and the practice of pediatrics. The importance of homes in children's lives, history of healthy homes, asthma, and exposures to lead, carbon monoxide, secondhand/thirdhand smoke, radon, allergy triggers is discussed, as well as how changes in ambient temperature, increased humidity, poor ventilation, water quality, infectious diseases, housing structure, guns, electronic media, family structure, and domestic violence all affect children's health. Copyright © 2013 Mosby, Inc. All rights reserved.

  15. Population and Housing Unit Estimates

    Science.gov (United States)

    Employment and Payroll Survey of Business Owners Work from Home Our statistics highlight trends in household statistics from multiple surveys. Data Tools & Apps Main American FactFinder Census Business Builder My Classification Codes (i.e., NAICS) Economic Census Economic Indicators Economic Studies Industry Statistics

  16. A programmable electronic Microplex Driver Unit for readout of silicon strip detectors

    International Nuclear Information System (INIS)

    Bairstow, R.

    1990-08-01

    The unit provides the necessary signals to drive arrays of Microplex devices used to readout silicon strip Vertex detectors as used in DELPHI and OPAL at CERN. The unit has a CAMAC interface allowing operation of the unit by computer in a Remote-control mode. The computer can control all the essential parameters of the drive signals, together with the operational characteristics of the system. Alternatively, the unit can be used in a stand-alone Local-control mode. In this case the front panel controls and displays enable the user to set up the unit. (author)

  17. Allegheny County Poor Housing Conditions

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This estimate of the percent of distressed housing units in each Census Tract was prepared using data from the American Community Survey and the Allegheny County...

  18. Malaysian Affordability Housing Policies Revisited

    Directory of Open Access Journals (Sweden)

    Samad Diwa

    2016-01-01

    Full Text Available Housing has always been a significant aspiration of family expression and distinctly priciest investment by household. It plays a momentous role in the country’s economy and so central to the societal well-being that is emplaced in the United Nation Universal declaration of Human rights. Yet in developed and developing world alike, cities struggle to provide decent housing for lower and middle income population. The provision of affordable housing is a major policy concern around the world with Malaysia being no exception; rising income hardly keep pace with price hike of housing unit and housing interventions has majorly concentrated on demand side leading to a non-responsive supply sector. Therefore, this paper highlights affordable housing issues pertaining Malaysia. It formulates Malaysian Map of affordability and conducts an evaluation of global housing schemes to better identify policy priorities for Malaysia. It’s significant to harmonize supply and demand side factors in the housing market to ensure that housing supply fits the needs of citizens based on the location, price and target group. In case of Malaysia supply oriented initiative are of urgency in short and medium run. This must be supported by long term demand side schemes in parallel. Convergence of these two factors is essential for a balanced equilibrium and obtaining affordability.

  19. 24/7 in-house intensivist coverage and fellowship education: a cross-sectional survey of academic medical centers in the United States.

    Science.gov (United States)

    Diaz-Guzman, Enrique; Colbert, Colleen Y; Mannino, David M; Davenport, Daniel L; Arroliga, Alejandro C

    2012-04-01

    The objectives of this study were to determine the current staffing models of practice and the frequency of 24/7 coverage in academic medical centers in the United States and to assess the perceptions of critical care trainees and program directors toward these models. A cross-sectional national survey was conducted using an Internet-based survey platform. The survey was distributed to fellows and program directors of 374 critical care training programs in US academic medical centers. We received 518 responses: 138 from program directors (PDs) (37% of 374 programs) and 380 fellow responses. Coverage by a board-certified or board-eligible intensivist physician 24/7 was reported by 33% of PD respondents and was more common among pediatric and surgical critical care programs. Mandatory in-house call for critical care trainees was reported by 48% of the PDs. Mandatory call was also more common among pediatric-critical care programs compared with the rest (P 24/7 coverage would be associated with better patient care in the ICU and improved education for the fellows, although 65% of them believed this model would have a negative impact on trainees' autonomy. Intensivist coverage 24/7 was not commonly used in US academic centers responding to our survey. Significant differences in coverage models among critical care medicine specialties appear to exist. Program director and trainee respondents believed that 24/7 coverage was associated with better outcomes and education but also expressed concerns about the impact of this model on fellows' autonomy.

  20. White House Office of the Vice President Announces New Memorandum of Understanding in Clinical Proteogenomics Between the United States and Australia | Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    The White House Office of the Vice President has announced the signing of three Memoranda of Understanding (MOUs) that will make available an unprecedented international dataset to advance cancer research and care.

  1. Active house

    DEFF Research Database (Denmark)

    Eriksen, Kurt Emil; Olesen, Gitte Gylling Hammershøj

    Formålet med dette abstrakt er at illustrere, at huse kan være konstrueret til at basere sig udelukkende på vedvarende energikilder og samtidig være CO2-neutrale og producere mere energi end de forbruger. Active House Visionen undersøger disse muligheder i otte demonstration huse i fem forskellige...

  2. Smart Houses

    Science.gov (United States)

    1987-01-01

    GWS takes plans for a new home and subjects them to intensive computerized analysis that does 10,000 calculations relative to expected heat loss and heat gain, then provides specifications designed specifically for each structure as to heating, cooling, ventilation and insulation. As construction progresses, GWS inspects the work of the electrical, plumbing and insulation contractors and installs its own Smart House Radiant Barrier. On completion of the home, GWS technicians use a machine that creates a vacuum in the house and enables computer calculation of the air exchanged, a measure of energy efficiency. Key factor is the radiant barrier, borrowed from the Apollo program. This is an adaptation of a highly effective aluminized heat shield as a radiation barrier holding in or keeping out heat, cold air and water vapor.

  3. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  4. House price responsiveness of housing investments across major European economies

    OpenAIRE

    Gattini, Luca; Ganoulis, Ioannis

    2012-01-01

    In comparison with the large literature on house prices, housing investments have been studied far less. This paper investigates the behaviour of private residential investments for the six largest European economies, namely: Germany, France, Italy, Spain, the Netherlands and the United Kingdom. It employs a common modelling structure based on an error correction approach and country specific models. First, co-integration among the parsimoniously specified set of fundamental variables is dete...

  5. Elder Abuse; Joint Hearing Before the Special Committee on Aging, United States Senate and the Select Committee on Aging, House of Representatives, Ninety-Sixth Congress, Second Session.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. Senate Special Committee on Aging.

    This report of a joint hearing before the Senate and House Committees on Aging examines elder abuse as a growing problem in America. The testimony considers the benefits of community-based services for the elderly living with relatives, explores other forms of long-term care, and investigates ways to aid victims of elder abuse. An overview of the…

  6. Determinants of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in house dust samples from four areas of the United States

    NARCIS (Netherlands)

    Deziel, N.C.; Nuckols, J.R.; Colt, J.S.; Roos, A.J. de; Pronk, A.; Gourley, C.; Severson, R.K.; Cozen, W.; Cerhan, J.R.; Hartge, P.; Ward, M.H.

    2012-01-01

    Determinants of levels of polychlorinated dibenzo- p-dioxins and polychlorinated dibenzofurans (PCDD/F) in dust in U.S. homes are not well characterized. We conducted a pilot study to evaluate the relationship between concentrations of PCDD/F in house dust and residential proximity to known sources,

  7. Sydney Opera House Rise

    DEFF Research Database (Denmark)

    2013-01-01

    Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House".......Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House"....

  8. 24 CFR 982.615 - Shared housing: Occupancy.

    Science.gov (United States)

    2010-04-01

    ... DEVELOPMENT SECTION 8 TENANT BASED ASSISTANCE: HOUSING CHOICE VOUCHER PROGRAM Special Housing Types Shared Housing § 982.615 Shared housing: Occupancy. (a) Sharing a unit. An assisted family may reside in shared...? (1) If approved by the HA, a live-in aide may reside with the family to care for a person with...

  9. 24 CFR 1006.101 - Housing plan requirements.

    Science.gov (United States)

    2010-04-01

    ... assistance provided by the United States, including loans, grants, and mortgage insurance; (iv) A description... State of Hawaii, including the availability of housing from other public sources and private market... period covered by the plan, including transitional housing; homeless housing; college housing; and...

  10. 24 CFR 200.929a - Fair Housing Accessibility Guidelines.

    Science.gov (United States)

    2010-04-01

    ... Guidelines. 200.929a Section 200.929a Housing and Urban Development Regulations Relating to Housing and Urban... Fair Housing Accessibility Guidelines. Builders and developers may use the Department's Fair Housing Accessibility Guideline when designing or constructing covered multifamily dwelling units in order to comply...

  11. Stirling micro cogeneration unit for single-family houses. Compact and assembly-friendly; Stirling-Mikro-BHKW fuer den Einsatz im Einfamilienhaus. Kompakt und montagefreundlich

    Energy Technology Data Exchange (ETDEWEB)

    Gimsa, Andreas [Enerlyt Technik GmbH, Potsdam (Germany)

    2010-07-01

    Enerlyt of Potsdam is a manufacturer working on a micro cogeneration unit based on a Stirling engine whose thermodynamic cycle has lower losses, e.g. by making the expansion pistons bigger than the compression pistons. The unit can be operated with various fuels. The author describes the function and state of development of the unit. (orig.)

  12. Housing markets and housing policies in India

    OpenAIRE

    Tiwari, Piyush; Rao, Jyoti

    2016-01-01

    Issues of housing in India are synonymous with ignorance of housing in active government involvement at the policy and program formulation levels. They are also due to the problems that unplanned urbanization, income disparity, poverty, illiteracy, and unemployment brought. These issues extenuated the housing problem, causing a housing shortage of 51 million in 2011. Though India has a long history of establishing policies, programs, and institutions to cater to housing, without allocating ad...

  13. Housing Programs for Homeless Individuals With Mental Illness: Effects on Housing and Mental Health Outcomes.

    Science.gov (United States)

    Benston, Elizabeth A

    2015-08-01

    This systematic review analyzed the best available research in the United States on permanent supportive housing programs for homeless individuals with mental illness and the effect of these programs on housing status and mental health. It updates older and broader reviews that included weaker studies or those that did not analyze permanent housing as an input and housing and mental health as primary outcomes. The literature search (1980-2013) yielded 14 studies (randomized controlled trials and quasi-experimental studies). The studies found that a majority of participants placed in experimental housing programs with case management support remained in housing for at least one year or experienced more days housed than homeless relative to a comparison group. Although this finding is in line with previous literature reviews on permanent supportive housing, this analysis found limitations in each of the 14 reviewed studies, such as attrition, selection and response bias, imprecise definitions and implementation of housing programs, and a lack of appropriate controls. Only three of the reviewed studies reported using a housing fidelity assessment tool to test whether the housing intervention was faithful to theoretical standards, and conceptions and implementation of housing varied widely across studies, threatening internal and external validity. Pitfalls in the best available studies on permanent supportive housing programs in the United States limit the ability of research to inform the policy goal of ending chronic homelessness and demonstrate a need for further experimental research upon which to make funding and policy decisions, especially in light of prioritized federal funds.

  14. Multifamily Housing Rehabilitation Process Improvements

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, Marshall L. [Partnership for Home Innovation, Upper Marlboro, MD (United States); Francisco, Abby [Partnership for Home Innovation, Upper Marlboro, MD (United States); Roberts, Sydney G. [Partnership for Home Innovation, Upper Marlboro, MD (United States)

    2016-03-01

    Rea Ventures Group, LLC (Rea Ventures) partnered with Southface Energy Institute (Southface)—a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team—to rehabilitate 418 low-income multifamily rental apartments located at 14 properties in Georgia (International Energy Conservation Code Climate Zones 2–4). These 22-year-old units with individual utility meters were arranged in row house or townhouse style. Rehabilitation plans were developed using a process prescribed by the U.S. Department of Agriculture (USDA) Rural Development program, which partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide; this housing includes more than 14,000 existing multifamily housing developments. In 2012, more than $100 million in grants and loans were allocated for that purpose.

  15. Rethinking Affordable Housing Delivery: An Analytical Insight

    Directory of Open Access Journals (Sweden)

    Olanrewaju Abdullateef

    2016-01-01

    Full Text Available Malaysia currently has a housing shortage of 12 million units. Towards the year 2020, this would require an annual supply of a minimum of 2 million homes. With the current production rate, the deficits will remain over the next 100 years. The crisis will lead to poor standards of living, un-affordable rental price, high mortgage payment, abandonment, and dilapidation of the existing housing stock. Lack of affordable housing is already a source of concern among many Malaysians. The middle and lower income earners spend more than 30% of their income on rent or for mortgage payment. Housing rent or mortgage is a basic need like foods, education, clothing and health. The government has introduced various measures to address the housing deficit. Despite these measures, the housing supply and distribution gaps continue to grow. To better understand the issues, there is a need to examine how the procurement planning in the affordable housing delivery supply chain and market is formulated, explore how cost of affordable housing would be reduced, identify the user value systems in affordable housing, and identify the criteria in the current regulatory framework? For these purposes, this paper reviews the relevant literature to reach preliminary findings on the stated issues. Among the factors found accounting for housing shortages, the overwhelming factors were that of poor policies, strategies, practice, management, and finance. The findings are meaningful in framing an affordable housing delivery model. It could also be useful to stakeholders involved in affordable housing delivery in Malaysia and elsewhere.

  16. TARP Monthly Housing Scorecard

    Data.gov (United States)

    Department of the Treasury — Treasury and the U.S. Department of Housing and Urban Development (HUD) jointly produce a Monthly Housing Scorecard on the health of the nation’s housing market. The...

  17. EnviroAtlas - Housing in the Conterminous U.S. Web Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas web service includes maps that illustrate the number and density of housing units. Housing density and the proximity of housing to employment can...

  18. 24 CFR 791.402 - Determination of low-income housing needs.

    Science.gov (United States)

    2010-04-01

    ... ASSISTANCE PROGRAMS AND PUBLIC AND INDIAN HOUSING PROGRAMS) ALLOCATIONS OF HOUSING ASSISTANCE FUNDS... housing units that would be required to maintain vacancies at levels typical of balanced market conditions...

  19. Housing First or no housing? Housing and homelessness at the end of alcohol and drug treatment.

    Science.gov (United States)

    Dyb, Evelyn

    2016-10-01

    The rate of alcohol and drug dependency is high among homeless persons in Norway as well as in other Western societies. National homeless surveys also show a certain correlation between discharge from institutions and homelessness. However, the rate of homelessness versus the rate with fixed abode at the end of specialised alcohol and drug treatment has not been examined using quantitative methods. A cross-sectional survey was conducted in alcohol and drug treatment units in the national health services and private clinics. The survey investigates the housing outcome at the end of treatment compared to the situation at the start of treatment using an individual questionnaire for patients ending treatment in a specific time window. Housing outcome is measured by the odds ratio of having a fixed abode at the end of treatment in relation to main intoxicating substance, type of treatment (in- and outpatient), completing versus cutting short the treatment, housing situation at the start of treatment, socioeconomic capital, mental health problems, individual plan, medical assisted treatment, and a set of background variables. The housing versus homeless situation hardly changes during the treatment period. In both a bivariate analysis and a simple multivariate model, principal intoxicating substance is the strongest predictor of having a fixed abode both before and after treatment. However, a more sophisticated analysis indicates that socioeconomic resources and social capital play along with the preferred intoxicating substance as predictors of having permanent housing. After more than a decade of a housing-led national homeless policy, and wide embracement of Housing First approaches in the European Union, homeless persons entering specialised alcohol and drug treatment are likely to return to the streets and hostels at the end of treatment. Access to housing after treatment is very limited for those lacking resources to solve their housing problem without assistance

  20. 24 CFR 970.31 - Replacement units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Replacement units. 970.31 Section... PUBLIC HOUSING PROGRAM-DEMOLITION OR DISPOSITION OF PUBLIC HOUSING PROJECTS § 970.31 Replacement units. Notwithstanding any other provision of law, replacement public housing units may be built on the original public...

  1. HOUSING UNITS Units in Structure for Occupied Units NMSD 2000

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — The 2006 Second Edition TIGER/Line files are an extract of selected geographic and cartographic information from the Census TIGER database. The geographic coverage...

  2. HOUSING UNITS Units in Structure for Occupied Units NMHD 2000

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — The 2006 Second Edition TIGER/Line files are an extract of selected geographic and cartographic information from the Census TIGER database. The geographic coverage...

  3. White House Communications Agency

    National Research Council Canada - National Science Library

    Gimble, Thomas

    1995-01-01

    The Chairman, House Committee on Government Reform and Oversight; the Chairman, House Subcommittee on National Security, International Affairs, and Criminal Justice, Committee on Government Reform and Oversight...

  4. A dataset of housing market and self-attitudes towards housing location choices in Alexandria, Egypt.

    Science.gov (United States)

    Ibrahim, Mohamed R

    2017-04-01

    A survey, of sample size 224, is designed to include the different related-factors to housing location choice, such as; socioeconomic factors, housing characteristics, travel behavior, current self-selection factors, housing demand and future location preferences. It comprises 16 questions, categorized into three different sections; socioeconomic (5 Questions), current dwelling unit characteristics (7 Questions), and housing demand characteristics (4 Questions). The first part, socioeconomic, covers the basic information about the respondent, such as; age, gender, marital status, employment, and car ownership. While the second part, current dwelling unit characteristics, covers different aspect concerning the residential unit typology, financial aspects, and travel behavior of the respondent. It includes the tenure types of the residential unit, estimation of the unit price (in the case of ownership or renting), housing typologies, the main reason for choosing the unit, in case of working, the modes of travel to work, and time to reach it, residential mobility in the last decade, and the ownership of any other residential units. The last part, housing demand characteristics, covers the size of the demand for a residential unit, preference in living in a certain area and the reason to choose it, and the preference of residential unit׳s tenure. This survey is a representative sample for the population in Alexandria, Egypt. The data in this article is represented in: How do people select their residential locations in Egypt? The case of Alexandria; JCIT1757.

  5. A dataset of housing market and self-attitudes towards housing location choices in Alexandria, Egypt

    Directory of Open Access Journals (Sweden)

    Mohamed R. Ibrahim

    2017-04-01

    Full Text Available A survey, of sample size 224, is designed to include the different related-factors to housing location choice, such as; socioeconomic factors, housing characteristics, travel behavior, current self-selection factors, housing demand and future location preferences. It comprises 16 questions, categorized into three different sections; socioeconomic (5 Questions, current dwelling unit characteristics (7 Questions, and housing demand characteristics (4 Questions. The first part, socioeconomic, covers the basic information about the respondent, such as; age, gender, marital status, employment, and car ownership. While the second part, current dwelling unit characteristics, covers different aspect concerning the residential unit typology, financial aspects, and travel behavior of the respondent. It includes the tenure types of the residential unit, estimation of the unit price (in the case of ownership or renting, housing typologies, the main reason for choosing the unit, in case of working, the modes of travel to work, and time to reach it, residential mobility in the last decade, and the ownership of any other residential units. The last part, housing demand characteristics, covers the size of the demand for a residential unit, preference in living in a certain area and the reason to choose it, and the preference of residential unit׳s tenure. This survey is a representative sample for the population in Alexandria, Egypt. The data in this article is represented in: How do people select their residential locations in Egypt? The case of Alexandria; JCIT1757.

  6. 24 CFR 982.616 - Shared housing: Lease and HAP contract.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Shared housing: Lease and HAP... Types Shared Housing § 982.616 Shared housing: Lease and HAP contract. For assistance in a shared housing unit, there is a separate HAP contract and lease for each assisted family. ...

  7. Family Open House

    Science.gov (United States)

    Search Family Open House Join us for an afternoon of science fun. The Fermilab Family Open House is a party for children of all ages to learn about the world of physics. The Open House is supported by Open House? Check out our YouTube video to learn more! Explore physics concepts with hands-on

  8. ENERGY STAR Unit Reports

    Data.gov (United States)

    Department of Housing and Urban Development — These quarterly Federal Fiscal Year performance reports track the ENERGY STAR qualified HOME units that Participating Jurisdictions record in HUD's Integrated...

  9. A centroid model of species distribution with applications to the Carolina wren Thryothorus ludovicianus and house finch Haemorhous mexicanus in the United States

    Science.gov (United States)

    Huang, Qiongyu; Sauer, John R.; Swatantran, Anu; Dubayah, Ralph

    2016-01-01

    Drastic shifts in species distributions are a cause of concern for ecologists. Such shifts pose great threat to biodiversity especially under unprecedented anthropogenic and natural disturbances. Many studies have documented recent shifts in species distributions. However, most of these studies are limited to regional scales, and do not consider the abundance structure within species ranges. Developing methods to detect systematic changes in species distributions over their full ranges is critical for understanding the impact of changing environments and for successful conservation planning. Here, we demonstrate a centroid model for range-wide analysis of distribution shifts using the North American Breeding Bird Survey. The centroid model is based on a hierarchical Bayesian framework which models population change within physiographic strata while accounting for several factors affecting species detectability. Yearly abundance-weighted range centroids are estimated. As case studies, we derive annual centroids for the Carolina wren and house finch in their ranges in the U.S. We further evaluate the first-difference correlation between species’ centroid movement and changes in winter severity, total population abundance. We also examined associations of change in centroids from sub-ranges. Change in full-range centroid movements of Carolina wren significantly correlate with snow cover days (r = −0.58). For both species, the full-range centroid shifts also have strong correlation with total abundance (r = 0.65, and 0.51 respectively). The movements of the full-range centroids of the two species are correlated strongly (up to r = 0.76) with that of the sub-ranges with more drastic population changes. Our study demonstrates the usefulness of centroids for analyzing distribution changes in a two-dimensional spatial context. Particularly it highlights applications that associate the centroid with factors such as environmental stressors, population characteristics

  10. Affordable housing as a niche product: The case of the Danish “SocialHousing Plus”

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole; Stensgaard, Anne Gro

    Establishing affordable housing is a growing demand in many larger cities there is however a number of challenges related to establishing affordable housing, as well as many different approaches. This paper presents a case-study of an affordable housing concept in the Danish social housing sector......, the “SocialHousing Plus” (“AlmenBolig+”) which is based on lowering production costs as well as operation costs including residential self-management, large-scale production of pre-fab housing units, low-energy solutions and other innovative approaches. The concept was developed in 2007, and has so far...... resulted in the production of more than 1.500 dwellings. The paper will discuss the results of the concept, and the various challenges related to it. Based on the theory of Technological Transition (Geels, 2002) it will discuss the options and limitations of providing affordable housing through developing...

  11. Innova House - Ottawa`s advanced house

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-31

    A pilot program was developed to provide the housing industry with a means to field test innovative technologies, products and building systems, and to evaluate their overall performance. Under Canada`s Advanced House Program, ten demonstration houses were designed, built and monitored. Ottawa`s Innova House, was one of the ten houses built for this program. The innovative energy saving features of the house included (1) air distribution with small diameter ducts and an electronically commutated motor, a 2.6 kW grid-connected photovoltaic system, (3) an energy recovery ventilator (ERV) with free-cooling mode, (4) a 94 per cent efficient integrated gas heating and hot water system, (5) airtight drywall construction, (6) CFC-free exterior insulation, (7) a natural-gas-engine heat pump for air conditioning, (8) a prototype sealed combustion gas range and clothes dryer, and (9) a manifold plumbing system to conserve water. It was designed to consume one half of the energy consumed in an R-2000 home and one third of the energy of a conventional house. Several of the mechanical elements did not perform at expected levels, (lower than expected efficiencies from the heating and cooling systems and a malfunctioning ERV), nevertheless, overall performance of the house was still very close to the targets. The construction and operation of the house was described. tabs., figs.

  12. Buying first or selling first in housing markets

    NARCIS (Netherlands)

    Moen, E.R.; Nenov, P.T.; Sniekers, F.

    2015-01-01

    Housing transactions by owner‐occupiers take two steps, purchase of a new property and sale of the old housing unit. This paper shows how the transaction sequence decision of owner‐occupiers depends on, and in turn, affects housing market conditions in an equilibrium search‐and‐matching model of the

  13. Overcrowding of Residential Houses in Ethiopia: A Study of ...

    African Journals Online (AJOL)

    Existing housing related evidences attest to the fact that many Ethiopians live in houses that are not conducive for healthy life. This article examines the nature of overcrowding of residential units in Ethiopia using the 2007 Population and Housing Census data supported by literature. Descriptive and multivariate statistical ...

  14. How Well Are We Housed? 2. Female-Headed Households.

    Science.gov (United States)

    Limmer, Ruth

    This summary of data on female-headed households indicates that most live in housing that is older and less adequate than that of the general population; the housing units are more often rented than owned; and women in this category must spend a greater proportion of their income on housing than does the general population. Data also show that if…

  15. The design and development of a solar tracking unit

    Science.gov (United States)

    Jones, I. W.; Miller, J. B.

    1984-01-01

    The solar tracking unit was developed to support the Laser Heterodyne Spectrometer (LHS) airborne instrument, but has application to a general class of airborne solar occultation research instruments. The unit consists of a mirror mounted on two gimbals, one of which is hollow. The mirror reflects a 7.6 cm (3.0 in.) diameter beam of sunlight through the hollow gimbal into the research instrument optical axis. A portion of the reflected sunlight is directed into a tracking telescope which uses a four quadrant silicon detector to produce the servo error signals. The colinearity of the tracker output beam and the research instrument optical axis is maintained to better than + or - 1 arc-minute. The unit is microcomputer controlled and is capable of stand alone operation, including automatic Sun acquisition or operation under the control of the research instrument.

  16. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    Science.gov (United States)

    Wang, Huijun; Qu, Zheng; Tang, Shaofei; Pang, Mingqi; Zhang, Mingju

    2017-08-01

    In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  17. environmental/climatic effect on stand-alone solar energy supply

    African Journals Online (AJOL)

    This paper investigates the climatic effects and environmental variations on the perfor- mance of a ... inter-connected arrays due to shades from clouds, tress and ... Modeling of Solar Module .... needs. The earth revolves around the sun in an.

  18. Letting Go of Stand-Alone Technology: How to Blend Technology into Literacy Stations

    Science.gov (United States)

    Calvert, Heather

    2015-01-01

    With the nationwide focus on increasing students understanding and use of technology, many teachers are beginning to incorporate a variety of technology into small group rotations. However, the use of technology during these rotations often does not require students to use higher level thinking or problem solving skills. By eliminating the…

  19. Sizing and economic analysis of stand alone photovoltaic system with hydrogen storage

    Science.gov (United States)

    Nordin, N. D.; Rahman, H. A.

    2017-11-01

    This paper proposes a design steps in sizing of standalone photovoltaic system with hydrogen storage using intuitive method. The main advantage of this method is it uses a direct mathematical approach to find system’s size based on daily load consumption and average irradiation data. The keys of system design are to satisfy a pre-determined load requirement and maintain hydrogen storage’s state of charge during low solar irradiation period. To test the effectiveness of the proposed method, a case study is conducted using Kuala Lumpur’s generated meteorological data and rural area’s typical daily load profile of 2.215 kWh. In addition, an economic analysis is performed to appraise the proposed system feasibility. The finding shows that the levelized cost of energy for proposed system is RM 1.98 kWh. However, based on sizing results obtained using a published method with AGM battery as back-up supply, the system cost is lower and more economically viable. The feasibility of PV system with hydrogen storage can be improved if the efficiency of hydrogen storage technologies significantly increases in the future. Hence, a sensitivity analysis is performed to verify the effect of electrolyzer and fuel cell efficiencies towards levelized cost of energy. Efficiencies of electrolyzer and fuel cell available in current market are validated using laboratory’s experimental data. This finding is needed to envisage the applicability of photovoltaic system with hydrogen storage as a future power supply source in Malaysia.

  20. Assessing Self-Regulation of Learning Dimensions in a Stand-alone MOOC Platform

    Directory of Open Access Journals (Sweden)

    Daniel Friday Owoichoche Onah

    2017-06-01

    Full Text Available A capacity for self-regulated learning (SRL has long been recognised as an important factor in successful studies. Although educational researchers have started to investigate the concept of SRL in the context of online education, very little is yet known about SRL in relation to massive open online courses (MOOCs or of appropriate strategies to foster SRL skills in MOOC learners. Self-regulation is particularly important in a MOOC-based study, which demands effective independent learning, and where widely acknowledged high dropout rates are observed. This study reports an investigation and assessment of the concept of SRL using a novel MOOC platform (eLDa by providing study options (either via a self-directed learning or instructor-led learning using a novel learning tool. In view of this, the research presents general description of self-regulated learning and explored the various existing dimensions used to expose the learners SRL skills. Drawing comparison of the online tool, the results and findings of the data were analysed. The study dis¬cusses how the various dimensions contributed to the knowledge representation of the self-regulated learning abilities shown by the learners. We present how these SRL dimensions captured using the measuring instrument contributes to our growing understanding of the distinctive features of the individual learner’s self-regulated learning. MOOCs success required a high performance of self-regulated learning abilities which at the moment very little has shown these degree of supporting SRL skills. This paper presents preliminary evaluation of a novel e-learning tool known, as ‘eLDa’ developed to implement this investi¬gation of self-regulation of learning. The research applied a modified online self-regulated learning questionnaire (OSLQ as the instrument to measure the SRL skills. The modified questionnaire known as MOOC OSLQ (MOSLQ was developed with a 19-item scale questions that exposes the six SRL dimensions used in this study.

  1. Perancangan Photovoltaic Stand Alone Sebagai Catu Daya Pada Base Transceiver Station Telekomunikasi Di Pulau Nusa Penida

    Directory of Open Access Journals (Sweden)

    I P Eka Indrawan

    2013-06-01

    Full Text Available Salah satu perangkat dalam jaringan komunikasi seluler adalah BTS (Base Transceiver Station. BTS yang ada di pulau Nusa Penida adalah BTS Nusa Penida dengan alamat desa kutampi dengan luas 500 m2. Sistem kelistrikan BTS  Nusa Penida dipasok oleh PLN dan genset,  dimana pada saat terjadi pemadaman energi listrik pada umumnya mempergunakan genset sebagai sumber energi listrik. Penggunaan genset mengakibatkan biaya operasional sangat tinggi, untuk itu diperlukan sumber lain yang lebih efisien. Besarnya potensi insolasi sinar harian matahari di Nusa penida, bisa sebagai  alternatif lain untuk sumber energi listrik dimana energi matahari bisa sebagai energi terbarukan untuk catu daya tambahan di BTS Nusa Penida yang pada akhirnya dapat menjaga  kestabilan suplai energi listrik ke BTS dan akses masyarakat terhadap informasi melalui seluler menjadi tidak terganggu. PV (Photovoltaic merupakan salah satu energi terbarukan yang dapat digunakan sebagai energi terbarukan untuk catu daya tambahan di BTS. Sistem PV yang dikembangkan untuk mensuplai energi listrik di BTS direncanakan sebesar 25%, adalah sistem PV yang hybrid dengan suplai listrik PLN. Besar daya PV yang dibangkitkan untuk mensuplai energi listrik di BTS adalah 9 kWp, yang dihasilkan dari panel PV sebanyak 45 panel dengan kapasitas panel PV adalah 200Wp dan kapasitas baterai yang akan digunakan adalah 3.800 Ah dengan total baterai 16. Analisis kelayakan investasi PV tanpa baterai dan PV dengan baterai yang dilakukan dengan menggunakan NPV, PI dan DPP menunjukkan hasil bahwa investasi PV layak untuk dilaksanakan. Untuk nilai NPV dan PI didapatkan kedua hasil investasi (> 0. Sedangkan untuk DPP didapatkan kedua hasil investasi dihasilkan lebih kecil dari periode umur proyek yang sudah ditetapkan, yaitu selama 25 tahun.

  2. Transforming stand-alone expert system into a community of cooperating agents

    CERN Document Server

    Jennings, N R; Aarnts, R P; Fuchs, J; Skarek, Paul

    1993-01-01

    Distributed Artificial Intelligence (DAI) systems in which multiple problem solving agents cooperate to achieve a common objective is a rapidly emerging and promising technology. However, as yet, there have been relatively few reported cases of such systems being employed to tackle real-world problems in realistic domains. One of the reasons for this is that DAI researchers have given virtually no consideration to the process of incorporating pre-existing systems into a community of cooperating agents. Yet reuse is a primary consideration for any organisation with a large software base. To redress the balance, this paper reports on an experiment undertaken at the CERN laboratories, in which two pre-existing and standalone expert systems for diagnosing faults in a particle accelerator were transformed into a community of cooperating agents. The experiences and insights gained during this process provide a valuable first step towards satisfying the needs of potential users of DAI technology - identifying the ty...

  3. New Scheme for Seamless Operation for Stand-Alone Power Systems

    Directory of Open Access Journals (Sweden)

    Hyun-Jun Kim

    2016-06-01

    Full Text Available On remote islands photovoltaic (PV panels with battery energy storage systems (BESSs supply electric power to customers in parallel operation with engine generators (EGs to reduce fuel consumption and environmental burden. A BESS operates in voltage control mode when it supplies power to loads alone, while it operates in current control mode when it supplies power to loads in parallel with the EG. This paper proposes a smooth mode change of the BESS from current control to voltage control by using initial value at the output of integral part in the voltage controller, and a smooth mode change from voltage control to current control by tracking the EG output voltage to the BESS output voltage using a phase-locked loop (PLL. The feasibility of the proposed scheme was verified through computer simulations and experiments with a scaled prototype.

  4. Feedforward control strategy for the state-decoupling Stand-alone UPS with LC output filter

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    . In order to further increase the load current disturbance rejection capability of the state-decoupling in UPS system, a feedforward control strategy is proposed. In addition, the design principle for the current and voltage regulators are discussed. Simulation and experimental results are provided......In this paper, the disturbance rejection performance of the cascaded control strategy for UPS system is investigated. The comparison of closed loop system performance between conventional cascaded control (CCC) strategy and state-decoupling cascaded control (SDCC) strategy are further explored...

  5. APT - NASA ENHANCED VERSION OF AUTOMATICALLY PROGRAMMED TOOL SOFTWARE - STAND-ALONE VERSION

    Science.gov (United States)

    Premo, D. A.

    1994-01-01

    The APT code is one of the most widely used software tools for complex numerically controlled (N/C) machining. APT is an acronym for Automatically Programmed Tools and is used to denote both a language and the computer software that processes that language. Development of the APT language and software system was begun over twenty years ago as a U. S. government sponsored industry and university research effort. APT is a "problem oriented" language that was developed for the explicit purpose of aiding the N/C machine tools. Machine-tool instructions and geometry definitions are written in the APT language to constitute a "part program." The APT part program is processed by the APT software to produce a cutter location (CL) file. This CL file may then be processed by user supplied post processors to convert the CL data into a form suitable for a particular N/C machine tool. This June, 1989 offering of the APT system represents an adaptation, with enhancements, of the public domain version of APT IV/SSX8 to the DEC VAX-11/780 for use by the Engineering Services Division of the NASA Goddard Space Flight Center. Enhancements include the super pocket feature which allows concave and convex polygon shapes of up to 40 points including shapes that overlap, that leave islands of material within the pocket, and that have one or more arcs as part of the pocket boundary. Recent modifications to APT include a rework of the POCKET subroutine and correction of an error that prevented the use within a macro of a macro variable cutter move statement combined with macro variable double check surfaces. Former modifications included the expansion of array and buffer sizes to accommodate larger part programs, and the insertion of a few user friendly error messages. The APT system software on the DEC VAX-11/780 is organized into two separate programs: the load complex and the APT processor. The load complex handles the table initiation phase and is usually only run when changes to the APT processor capabilities are made. This phase initializes character recognition and syntax tables for the APT processor by creating FORTRAN block data programs. The APT processor consists of four components: the translator, the execution complex, the subroutine library, and the CL editor. The translator examines each APT statement in the part program for recognizable structure and generates a new statement, or series of statements, in an intermediate language. The execution complex processes all of the definition, motion, and related statements to generate cutter location coordinates. The subroutine library contains routines defining the algorithms required to process the sequenced list of intermediate language commands generated by the translator. The CL editor re-processes the cutter location coordinates according to user supplied commands to generate a final CL file. A sample post processor is also included which translates a CL file into a form for use with a Wales Strippit Fabramatic Model 30/30 sheet metal punch. The user should be able to readily develop post processors for other N/C machine tools. The APT language is a statement oriented, sequence dependent language. With the exception of such programming techniques as looping and macros, statements in an APT program are executed in a strict first-to-last sequence. In order to provide programming capability for the broadest possible range of parts and of machine tools, APT input (and output) is generalized, as represented by 3-dimensional geometry and tools, and arbitrarily uniform, as represented by the moving tool concept and output data in absolute coordinates. A command procedure allows the user to select the desired part program, ask for a graphics file of cutter motions in IGES format, and submit the procedure as a batch job, if desired. The APT system software is written in FORTRAN 77 for batch and interactive execution and has been implemented on a DEC VAX series computer under VMS 4.4. The enhancements for this version of APT were last updated in June, 1989. The NASA adaptation, with enhancements, of the public domain version of the APT IV/SSX8 software to the DEC VAX-11/780 is available by license for a period of ten (10) years to approved licensees. The licensed program product delivered includes the APT IV/SSX8 system source code, object code, executable images, and command procedures and one set of supporting documentation. Additional copies of the supporting documentation may be purchased at any time at the price indicated below.

  6. A high-performance stand-alone solar PV power system for LED lighting

    KAUST Repository

    Huang, B. J.

    2010-06-01

    The present study developed a high-performance solar PV power technology for the LED lighting of a solar home system. The nMPPO (near-Maximum-Power- Point- Operation) design is employed in system design to eliminate MPPT. A feedback control system using pulse width modulation (PWM) technique was developed for battery charging control which can increase the charging capacity by 78%. For high-efficiency lighting, the LED is directly driven by battery using a PWM discharge control to eliminate a DC/DC converter. Two solar-powered LED lighting systems (50W and 100W LED) were built. The long-term outdoor tests have shown that the loss of load probability for full-night lighting requirement is zero for 50W LED and 3.6% for 100W LED. © 2010 IEEE.

  7. A high-performance stand-alone solar PV power system for LED lighting

    KAUST Repository

    Huang, B. J.; Hsu, P. C.; Wu, M. S.; Chen, K.Y.

    2010-01-01

    The present study developed a high-performance solar PV power technology for the LED lighting of a solar home system. The nMPPO (near-Maximum-Power- Point- Operation) design is employed in system design to eliminate MPPT. A feedback control system

  8. Last Stand-alone Beam Test of the Hadronic End-cap Calorimeter (HEC) Finished.

    CERN Multimedia

    Oberlack, H

    One quarter of all 134 HEC modules are tested with electron, pion and muon beams: two "partial HEC wheels", three HEC1 modules and three HEC2 modules, are used in a standard setup using the HEC cryostat in the H6 beam line. The picture shows a view of the set-up in the cryostat during the installation. MC results show that in this setup the energy leakage is well under control - well below 5 %. In addition, the other three quarters of modules are tested in technical cold tests. Using calibration signals, a detailed test of the cabling, cold electronics, crosstalk and noise performance is being done. The beam tests started with four prototype modules per run in '97, when technological optimization was still the key issue. From '98 onwards, modules of the "module 0" type have been tested, typically in two run periods per year. Finally in '99 the series production has started, with first beam test of series modules in 2000. Since then 57 series modules have been cold tested, 24 of them actually in beam tests. T...

  9. Wind-driven stand-alone DFIG with battery and pumped hydro ...

    Indian Academy of Sciences (India)

    Renewable energy electric conversion system; induction generators; wind power generation; energy storage; power converters. ... converter, (ii) wide speed operation of wind-driven DFIG, (iii) reduced battery capacity, (iv) high energy storage using PHSP and (v) availability of continuous power to the isolated loads.

  10. Stand-alone Cosmic Muon Reconstruction Before Installation of the CMS Silicon Strip Tracker

    CERN Document Server

    Adam, W.; Dragicevic, M.; Friedl, M.; Fruhwirth, R.; Hansel, S.; Hrubec, J.; Krammer, M.; Oberegger, M.; Pernicka, M.; Schmid, S.; Stark, R.; Steininger, H.; Uhl, D.; Waltenberger, W.; Widl, E.; Van Mechelen, P.; Cardaci, M.; Beaumont, W.; de Langhe, E.; de Wolf, E.A.; Delmeire, E.; Hashemi, M.; Bouhali, O.; Charaf, O.; Clerbaux, B.; Dewulf, J.-P.; Elgammal, S.; Hammad, G.; de Lentdecker, G.; Marage, P.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Adler, V.; Devroede, O.; De Weirdt, S.; D'Hondt, J.; Goorens, R.; Heyninck, J.; Maes, J.; Mozer, Matthias Ulrich; Tavernier, S.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Bonnet, J.-L.; Bruno, G.; De Callatay, B.; Florins, B.; Giammanco, A.; Gregoire, G.; Keutgen, Th.; Kcira, D.; Lemaitre, V.; Michotte, D.; Militaru, O.; Piotrzkowski, K.; Quertermont, L.; Roberfroid, V.; Rouby, X.; Teyssier, D.; Daubie, E.; Anttila, E.; Czellar, S.; Engstrom, P.; Harkonen, J.; Karimaki, V.; Kostesmaa, J.; Kuronen, A.; Lampen, T.; Linden, T.; Luukka, P.-R.; Maenpaa, T.; Michal, S.; Tuominen, E.; Tuominiemi, J.; Ageron, M.; Baulieu, G.; Bonnevaux, A.; Boudoul, G.; Chabanat, E.; Chabert, E.; Chierici, R.; Contardo, D.; Della Negra, R.; Dupasquier, T.; Gelin, G.; Giraud, N.; Guillot, G.; Estre, N.; Haroutunian, R.; Lumb, N.; Perries, S.; Schirra, F.; Trocme, B.; Vanzetto, S.; Agram, J.-L.; Blaes, R.; Drouhin, F.; Ernenwein, J.-P.; Fontaine, J.-C.; Berst, J.-D.; Brom, J.-M.; Didierjean, F.; Goerlach, U.; Graehling, P.; Gross, L.; Hosselet, J.; Juillot, P.; Lounis, A.; Maazouzi, C.; Olivetto, C.; Strub, R.; Van Hove, P.; Anagnostou, G.; Brauer, R.; Esser, H.; Feld, L.; Karpinski, W.; Klein, K.; Kukulies, C.; Olzem, J.; Ostapchuk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schwering, G.; Sprenger, D.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Beissel, F.; Bock, E.; Flugge, G.; Gillissen, C.; Hermanns, T.; Heydhausen, D.; Jahn, D.; Kaussen, G.; Linn, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Stahl, A.; Zoeller, M.H.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R.; Hauk, J.; Klanner, R.; Pein, U.; Schleper, P.; Steinbruck, G.; Blum, P.; De Boer, W.; Dierlamm, A.; Dirkes, G.; Fahrer, M.; Frey, M.; Furgeri, A.; Hartmann, F.; Heier, S.; Hoffmann, K.-H.; Kaminski, J.; Ledermann, B.; Liamsuwan, T.; Muller, S.; Muller, Th.; Schilling, F.-P.; Simonis, H.-J.; Steck, P.; Zhukov, V.; Cariola, P.; De Robertis, G.; Ferorelli, R.; Fiore, L.; Preda, M.; Sala, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Creanza, D.; De Filippis, N.; De Palma, M.; Giordano, D.; Maggi, G.; Manna, N.; My, S.; Selvaggi, G.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M.A.; Sparti, V.; Sutera, C.; Tricomi, A.; Tuve, C.; Brianzi, M.; Civinini, C.; Maletta, F.; Manolescu, F.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Broccolo, B.; Ciulli, V.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Magini, N.; Parrini, G.; Scarlini, E.; Cerati, G.; Azzi, P.; Bacchetta, N.; Candelori, A.; Dorigo, T.; Kaminsky, A.; Karaevski, S.; Khomenkov, V.; Reznikov, S.; Tessaro, M.; Bisello, D.; De Mattia, M.; Giubilato, P.; Loreti, M.; Mattiazzo, S.; Nigro, M.; Paccagnella, A.; Pantano, D.; Pozzobon, N.; Tosi, M.; Bilei, G.M.; Checcucci, B.; Fano, L.; Servoli, L.; Ambroglini, F.; Babucci, E.; Benedetti, D.; Biasini, M.; Caponeri, B.; Covarelli, R.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Marcantonini, M.; Postolache, V.; Santocchia, A.; Spiga, D.; Bagliesi, G.; Balestri, G.; Berretta, L.; Bianucci, S.; Boccali, T.; Bosi, F.; Bracci, F.; Castaldi, R.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A .S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Lomtadze, T.; Lungu, G.A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Sentenac, D.; Serban, A.T.; Slav, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tolaini, S.; Venturi, A.; Verdini, P.G.; Vos, M.; Zaccarelli, L.; Avanzini, C.; Basti, A.; Benucci, L.; Bocci, A.; Cazzola, U.; Fiori, F.; Linari, S.; Massa, M.; Messineo, A.; Segneri, G.; Tonelli, G.; Azzurri, P.; Bernardini, J.; Borrello, L.; Calzolari, F.; Foa, L.; Gennai, S.; Ligabue, F.; Petrucciani, G.; Rizzi, A.; Yang, Z.; Benotto, F.; Demaria, N.; Dumitrache, F.; Farano, R.; Borgia, M.A.; Castello, R.; Costa, M.; Migliore, E.; Romero, A.; Abbaneo, D.; Abbas, M.; Ahmed, I.; Akhtar, I.; Albert, E.; Bloch, C.; Breuker, H.; Butt, S.; Buchmuller, O.; Cattai, A.; Delaere, C.; Delattre, M.; Edera, L.M.; Engstrom, P.; Eppard, M.; Gateau, M.; Gill, K.; Giolo-Nicollerat, A.-S.; Grabit, R.; Honma, A.; Huhtinen, M.; Kloukinas, K.; Kortesmaa, J.; Kottelat, L.J.; Kuronen, A.; Leonardo, N.; Ljuslin, C.; Mannelli, M.; Masetti, L.; Marchioro, A.; Mersi, S.; Michal, S.; Mirabito, L.; Muffat-Joly, J.; Onnela, A.; Paillard, C.; Pal, I.; Pernot, J.F.; Petagna, P.; Petit, P.; Piccut, C.; Pioppi, M.; Postema, H.; Ranieri, R.; Ricci, D.; Rolandi, G.; Ronga, F.; Sigaud, C.; Syed, A.; Siegrist, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vander Donckt, M.; Vasey, F.; Alagoz, E.; Amsler, Claude; Chiochia, V.; Regenfus, Christian; Robmann, P.; Rochet, J.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Wilke, L.; Church, I.; Cole, J.; Coughlan, J.; Gay, A.; Taghavi, S.; Tomalin, I.; Bainbridge, R.; Cripps, N.; Fulcher, J.; Hall, G.; Noy, M.; Pesaresi, M.; Radicci, V.; Raymond, D.M.; Sharp, P.; Stoye, M.; Wingham, M.; Zorba, O.; Goitom, I.; Hobson, P.R.; Reid, I.; Teodorescu, L.; Hanson, G.; Jeng, G.-Y.; Liu, H.; Pasztor, G.; Satpathy, A.; Stringer, R.; Mangano, B.; Affolder, K.; Affolder, T.; Allen, A.; Barge, D.; Burke, S.; Callahan, D.; Campagnari, C.; Crook, A.; D'Alfonso, M.; Dietch, J.; Garberson, Jeffrey Ford; Hale, D.; Incandela, H.; Incandela, J.; Jaditz, S.; Kalavase, P.; Kreyer, S.; Kyre, S.; Lamb, J.; Mc Guinness, C.; Mills, C.; Nguyen, H.; Nikolic, M.; Lowette, S.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rubinstein, N.; Sanhueza, S.; Shah, Y.; Simms, L.; Staszak, D.; Stoner, J.; Stuart, D.; Swain, S.; Vlimant, J.-R.; White, D.; Ulmer, K.A.; Wagner, S.R.; Bagby, L.; Bhat, P.C.; Burkett, K.; Cihangir, S.; Gutsche, O.; Jensen, H.; Johnson, M.; Luzhetskiy, N.; Mason, D.; Miao, T.; Moccia, S.; Noeding, C.; Ronzhin, A.; Skup, E.; Spalding, W.J.; Spiegel, L.; Tkaczyk, S.; Yumiceva, F.; Zatserklyaniy, A.; Zerev, E.; Anghel, I.; Bazterra, V.E.; Gerber, C.E.; Khalatian, S.; Shabalina, E.; Baringer, Philip S.; Bean, A.; Chen, J.; Hinchey, C.; Martin, C.; Moulik, T.; Robinson, R.; Gritsan, A.V.; Lae, C.K.; Tran, N.V.; Everaerts, P.; Hahn, K.A.; Harris, P.; Nahn, S.; Rudolph, M.; Sung, K.; Betchart, B.; Demina, R.; Gotra, Y.; Korjenevski, S.; Miner, D.; Orbaker, D.; Christofek, L.; Hooper, R.; Landsberg, G.; Nguyen, D.; Narain, M.; Speer, T.; Tsang, K.V.

    2009-01-01

    The subsystems of the CMS silicon strip tracker were integrated and commissioned at the Tracker Integration Facility (TIF) in the period from November 2006 to July 2007. As part of the commissioning, large samples of cosmic ray data were recorded under various running conditions in the absence of a magnetic field. Cosmic rays detected by scintillation counters were used to trigger the readout of up to 15% of the final silicon strip detector, and over 4.7 million events were recorded. This document describes the cosmic track reconstruction and presents results on the performance of track and hit reconstruction as from dedicated analyses.

  11. Alignment of the CMS Silicon Strip Tracker during stand-alone Commissioning

    CERN Document Server

    Adam, W.; Dragicevic, M.; Friedl, M.; Fruhwirth, R.; Hansel, S.; Hrubec, J.; Krammer, M.; Oberegger, M.; Pernicka, M.; Schmid, S.; Stark, R.; Steininger, H.; Uhl, D.; Waltenberger, W.; Widl, E.; Van Mechelen, P.; Cardaci, M.; Beaumont, W.; de Langhe, E.; de Wolf, E.A.; Delmeire, E.; Hashemi, M.; Bouhali, O.; Charaf, O.; Clerbaux, B.; Dewulf, J.-P.; Elgammal, S.; Hammad, G.; de Lentdecker, G.; Marage, P.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Adler, V.; Devroede, O.; De Weirdt, S.; D'Hondt, J.; Goorens, R.; Heyninck, J.; Maes, J.; Mozer, Matthias Ulrich; Tavernier, S.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Bonnet, J.-L.; Bruno, G.; De Callatay, B.; Florins, B.; Giammanco, A.; Gregoire, G.; Keutgen, Th.; Kcira, D.; Lemaitre, V.; Michotte, D.; Militaru, O.; Piotrzkowski, K.; Quertermont, L.; Roberfroid, V.; Rouby, X.; Teyssier, D.; daubie, E.; Anttila, E.; Czellar, S.; Engstrom, P.; Harkonen, J.; Karimaki, V.; Kostesmaa, J.; Kuronen, A.; Lampen, T.; Linden, T.; Luukka, P.-R.; Maenaa, T.; Michal, S.; Tuominen, E.; Tuominiemi, J.; Ageron, M.; Baulieu, G.; Bonnevaux, A.; Boudoul, G.; Chabanat, E.; Chabert, E.; Chierici, R.; Contardo, D.; Della Negra, R.; Dupasquier, T.; Gelin, G.; Giraud, N.; Guillot, G.; Estre, N.; Haroutunian, R.; Lumb, N.; Perries, S.; Schirra, F.; Trocme, B.; Vanzetto, S.; Agram, J.-L.; Blaes, R.; Drouhin, F.; Ernenwein, J.-P.; Fontaine, J.-C.; Berst, J.-D.; Brom, J.-M.; Didierjean, F.; Goerlach, U.; Graehling, P.; Gross, L.; Hosselet, J.; Juillot, P.; Lounis, A.; Maazouzi, C.; Olivetto, C.; Strub, R.; Van Hove, P.; Anagnostou, G.; Brauer, R.; Esser, H.; Feld, L.; Karpinski, W.; Klein, K.; Kukulies, C.; Olzem, J.; Ostapchuk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schwering, G.; Sprenger, D.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Beissel, F.; Bock, E.; Flugge, G.; Gillissen, C.; Hermanns, T.; Heydhausen, D.; Jahn, D.; Kaussen, G.; Linn, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Stahl, A.; Zoeller, M.H.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R.; Hauk, J.; Klanner, R.; Pein, U.; Schleper, P.; Steinbruck, G.; Blum, P.; De Boer, W.; Dierlamm, A.; Dirkes, G.; Fahrer, M.; Frey, M.; Furgeri, A.; Hartmann, F.; Heier, S.; Hoffmann, K.-H.; Kaminski, J.; Ledermann, B.; Liamsuwan, T.; Muller, S.; Muller, Th.; Schilling, F.-P.; Simonis, H.-J.; Steck, P.; Zhukov, V.; Cariola, P.; De Robertis, G.; Ferorelli, R.; Fiore, L.; Preda, M.; Sala, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Creanza, D.; De Filippis, N.; De Palma, M.; Giordano, D.; Maggi, G.; Manna, N.; My, S.; Selvaggi, G.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M.A.; Sparti, V.; Sutera, C.; Tricomi, A.; Tuve, C.; Brianzi, M.; Civinini, C.; Maletta, F.; Manolescu, F.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Broccolo, B.; Ciulli, V.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Magini, N.; Parrini, G.; Scarlini, E.; Cerati, G.; Azzi, P.; Bacchetta, N.; Candelori, A.; Dorigo, T.; Kaminsky, A.; Karaevski, S.; Khomenkov, V.; Reznikov, S.; Tessaro, M.; Bisello, D.; De Mattia, M.; Giubilato, P.; Loreti, M.; Mattiazzo, S.; Nigro, M.; Paccagnella, A.; Pantano, D.; Pozzobon, N.; Tosi, M.; Bilei, G.M.; Checcucci, B.; Fano, L.; Servoli, L.; Ambroglini, F.; Babucci, E.; Benedetti, D.; Biasini, M.; Caponeri, B.; Covarelli, R.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Marcantonini, M.; Postolache, V.; Santocchia, A.; Spiga, D.; Bagliesi, G.; Balestri, G.; Berretta, L.; Bianucci, S.; Boccali, T.; Bosi, F.; Bracci, F.; Castaldi, R.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A.S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Lomtadze, T.; Lungu, G.A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Sentenac, D.; Serban, A.T.; Slav, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tolaini, S.; Venturi, A.; Verdini, P.G.; Vos, M.; Zaccarelli, L.; Avanzini, C.; Basti, A.; Benucci, L.; Bocci, A.; Cazzola, U.; Fiori, F.; Linari, S.; Massa, M.; Messineo, A.; Segneri, G.; Tonelli, G.; Azzurri, P.; Bernardini, J.; Borrello, L.; Calzolari, F.; Foa, L.; Gennai, S.; Ligabue, F.; Petrucciani, G.; Rizzi, A.; Yang, Z.; Benotto, F.; Demaria, N.; Dumitrache, F.; Farano, R.; Borgia, M.A.; Castello, R.; Costa, M.; Migliore, E.; Romero, A.; Abbaneo, D.; Abbas, M.; Ahmed, I.; Akhtar, I.; Albert, E.; Bloch, C.; Breuker, H.; Butt, S.; Buchmuller, O.; Cattai, A.; Delaere, C.; Delattre, M.; Edera, L.M.; Engstrom, P.; Eppard, M.; Gateau, M.; Gill, K.; Giolo-Nicollerat, A.-S.; Grabit, R.; Honma, A.; Huhtinen, M.; Kloukinas, K.; Kortesmaa, J.; Kottelat, L.J.; Kuronen, A.; Leonardo, N.; Ljuslin, C.; Mannelli, M.; Masetti, L.; Marchioro, A.; Mersi, S.; Michal, S.; Mirabito, L.; Muffat-Joly, J.; Onnela, A.; Paillard, C.; Pal, I.; Pernot, J.F.; Petagna, P.; Petit, P.; Piccut, C.; Pioppi, M.; Postema, H.; Ranieri, R.; Ricci, D.; Rolandi, G.; Ronga, F.; Sigaud, C.; Syed, A.; Siegrist, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vander Donckt, M.; Vasey, F.; Alagoz, E.; Amsler, Claude; Chiochia, V.; Regenfus, Christian; Robmann, P.; Rochet, J.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Wilke, L.; Church, I.; Cole, J.; Coughlan, J.; Gay, A.; Taghavi, S.; Tomalin, I.; Bainbridge, R.; Cripps, N.; Fulcher, J.; Hall, G.; Noy, M.; Pesaresi, M.; Radicci, V.; Raymond, D.M.; Sharp, P.; Stoye, M.; Wingham, M.; Zorba, O.; Goitom, I.; Hobson, P.R.; Reid, I.; Teodorescu, L.; Hanson, G.; Jeng, G.-Y.; Liu, H.; Pasztor, G.; Satpathy, A.; Stringer, R.; Mangano, B.; Affolder, K.; Affolder, T.; Allen, A.; Barge, D.; Burke, S.; Callahan, D.; Campagnari, C.; Crook, A.; D'Alfonso, M.; Dietch, J.; Garberson, Jeffrey Ford; Hale, D.; Incandela, H.; Incandela, J.; Jaditz, S.; Kalavase, P.; Kreyer, S.; Kyre, S.; Lamb, J.; Mc Guinnessr, C.; Mills, C.; Nguyen, H.; Nikolic, M.; Lowette, S.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rubinstein, N.; Sanhueza, S.; Shah, Y.; Simms, L.; Staszak, D.; Stoner, J.; Stuart, D.; Swain, S.; Vlimant, J.-R.; White, D.; Ulmer, K.A.; Wagner, S.R.; Bagby, L.; Bhat, P.C.; Burkett, K.; Cihangir, S.; Gutsche, O.; Jensen, H.; Johnson, M.; Luzhetskiy, N.; Mason, D.; Miao, T.; Moccia, S.; Noeding, C.; Ronzhin, A.; Skup, E.; Spalding, W.J.; Spiegel, L.; Tkaczyk, S.; Yumiceva, F.; Zatserklyaniy, A.; Zerev, E.; Anghel, I.; Bazterra, V.E.; Gerber, C.E.; Khalatian, S.; Shabalina, E.; Baringer, Philip S.; Bean, A.; Chen, J.; Hinchey, C.; Martin, C.; Moulik, T.; Robinson, R.; Gritsan, A.V.; Lae, C.K.; Tran, N.V.; Everaerts, P.; Hahn, K.A.; Harris, P.; Nahn, S.; Rudolph, M.; Sung, K.; Betchart, B.; Demina, R.; Gotra, Y.; Korjenevski, S.; Miner, D.; Orbaker, D.; Christofek, L.; Hooper, R.; Landsberg, G.; Nguyen, D.; Narain, M.; Speer, T.; Tsang, K.V.

    2009-01-01

    The results of the CMS tracker alignment analysis are presented using the data from cosmic tracks, optical survey information, and the laser alignment system at the Tracker Integration Facility at CERN. During several months of operation in the spring and summer of 2007, about five million cosmic track events were collected with a partially active CMS Tracker. This allowed us to perform first alignment of the active silicon modules with the cosmic tracks using three different statistical approaches; validate the survey and laser alignment system performance; and test the stability of Tracker structures under various stresses and temperatures ranging from +15C to -15C. Comparison with simulation shows that the achieved alignment precision in the barrel part of the tracker leads to residual distributions similar to those obtained with a random misalignment of 50 (80) microns in the outer (inner) part of the barrel.

  12. A Voltage and Frequency Control Strategy for Stand-Alone Full Converter Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Andrés Peña Asensio

    2018-02-01

    Full Text Available This paper addresses the design and analysis of a voltage and frequency control (VFC strategy for full converter (FC-based wind energy conversion systems (WECSs and its applicability for the supply of an isolated load. When supplying an isolated load, the role of the back-to-back converters in the FC must change with respect to a grid-connected application. Voltage and frequency are established by the FC line side converter (LSC, while the generator side converter (GSC is responsible for maintaining constant voltage in the DC link. Thus, the roles of the converters in the WECS are inverted. Under such control strategies, the LSC will automatically supply the load power and hence, in order to maintain a stable operation of the WECS, the wind turbine (WT power must also be controlled in a load-following strategy. The proposed VFC is fully modelled and a stability analysis is performed. Then, the operation of the WECS under the proposed VFC is simulated and tested on a real-time test bench, demonstrating the performance of the VFC for the isolated operation of the WECS.

  13. PV LED ENGINE characterization lab for stand alone light-to-light systems

    DEFF Research Database (Denmark)

    Poulsen, Peter Behrensdorff; Thorsteinsson, Sune; Lindén, Johannes

    2015-01-01

    dimming functions for reliable lighting. A barrier for exploiting use of standalone solar lighting for the urban environment seem to be lack of knowledge and lack of available tools for proper dimensioning. In this work the development of powerful dimensioning tool is described and initial measurements...... are presented. Furthermore, a laboratory has been build to characterize these systems up to 200 Wp from “nose to tail” in great details to support improvement of the systems and to make accurate field performance predictions by the dimensioning tool....

  14. Investigation of heating and cooling in a stand-alone high temperature PEM fuel cell system

    International Nuclear Information System (INIS)

    Zhang, Caizhi; Yu, Tao; Yi, Jun; Liu, Zhitao; Raj, Kamal Abdul Rasheedj; Xia, Lingchao; Tu, Zhengkai; Chan, Siew Hwa

    2016-01-01

    Highlights: • Heating-up and cooling-down processes of HT-PEMFC are the mainly interested topics. • Dynamic behaviours, power and energy demand of the heating and cooling was studied. • Hybrid system based on LiFeYPO_4 battery for heating and cooling is built and tested. • The concept of combining different heating sources together is recommended. - Abstract: One key issue pertaining to the cold-start of High temperature PEM fuel cell (HT-PEMFC) is the requirement of high amount of thermal energy for heating up the stack to a temperature of 120 °C or above before it can generate electricity. Furthermore, cooling down the stack to a certain temperature (e.g. 50 °C) is necessary before stopping. In this study, the dynamic behaviours, power and energy demand of a 6 kW liquid cooled HT-PEMFC stack during heating-up, operation and cooling-down were investigated experimentally. The dynamic behaviours of fuel cell under heating-up and cooling-down processes are the mainly interested topics. Then a hybridisation of HT-PEMFC with Li-ion battery to demonstrate the synergistic effect on dynamic behaviour was conducted and validated for its feasibility. At last, the concept of combining different heating sources together is analysed to reduce the heating time of the HT-PEMFC as well.

  15. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huijun, E-mail: huijun024@gmail.com [School of Instrumentation Science and Opto-electronics Engineering, Beihang University (China); Qu, Zheng; Tang, Shaofei; Pang, Mingqi [School of Instrumentation Science and Opto-electronics Engineering, Beihang University (China); Zhang, Mingju [Shanghai Aerospace Control Technology Institute, Shanghai (China)

    2017-08-15

    Highlights: • One novel permanent magnet generator structure has been proposed to reduce voltage regulation ratio. • Finite element method and equivalent circuit methods are both employed to realize rapid generator design. • Design of experiment (DOE) method is used to optimize permanent magnet shape for reduce voltage waveform distortion. • The obtained analysis and experiment results verify the proposed design methods. - Abstract: In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  16. Fuzzy Secondary Controller for Autonomous Stand-alone and Grid-connected AC Microgrid

    DEFF Research Database (Denmark)

    Neves, Rodolpho V. A.; Machado, Ricardo Q.; Oliveira, Vilma A.

    2016-01-01

    The present paper adresses the AC microgrid control issue using the hierarchical control structure and droop controllers for load sharing. Once the droop controllers impose an operation with frequency and voltage deviations, depending on the load and droop parameters, a hierarchical control...... structure must be added to change the droop controller operating points. The hierarchical controllers operate with local measurements and shared signals from communication links among the distributed generation systems connected to the microgrid. Depending on the geographical size of the microgrid......, the communication links can be economically unviable. This paper thus proposes a fuzzy secondary controller for AC microgrids to reduce the link communication dependency by using only local measurements. The simulation results show that the deviations as happened with the conventional secondary controllers can...

  17. Simulation of a stand-alone renewable hydrogen system for residential supply

    Directory of Open Access Journals (Sweden)

    Martín Hervello

    2014-01-01

    Full Text Available La simulación por ordenador es un primer paso lógico previo a la realización de un proyecto de una construcción física además de ser una herramienta para el diseño de redes de energía. Los sistemas combinados son una solución para mejorar la disponibilidad de la energía suministrada con medios renovables. El principal inconveniente de las fuentes de energías renovables es su naturaleza altamente estacional, con grandes variaciones en el tiempo que pueden impedir el uso como base de consumo y limitar las horas de máxima demanda. El objetivo de este trabajo es realizar simulaciones para comprobar la autosuficiencia energética de una vivienda unifamiliar en base a energías renovables (eólica, solar-fotovoltaica utilizando como medio de almacenamiento un sistema híbrido de baterías e hidrógeno. Para ello se ha utilizado el programa Simulink®-Matlab® teniendo en cuenta los datos meteorológicos proporcionados por METEO-Galicia. El modelo puede ser aplicado para determinar la viabilidad de implementar una red energética en regiones específicas, y predecir el flujo de energía y el comportamiento del sistema durante todo el año.

  18. Photovoltaic OLED Driver for Low-Power Stand-Alone Light-to-Light Systems

    DEFF Research Database (Denmark)

    Ploug, Rasmus Overgaard; Knott, Arnold

    2016-01-01

    of a three-port-converter for this purpose optimized for the specifications for driving an Organic Light Emitting Diode (OLED) panel intended for lighting purposes. By using a three-port-converter, featuring shared components for each conversion mode, the converter reaches 97 % efficiency at 1.8 W during...... conversion from photovoltaic panel to the battery, and 97 % in the area 1.4 W to 2 W for power delivery to the OLED....

  19. Stand-alone core sensitivity and uncertainty analysis of ALFRED from Monte Carlo simulations

    International Nuclear Information System (INIS)

    Pérez-Valseca, A.-D.; Espinosa-Paredes, G.; François, J.L.; Vázquez Rodríguez, A.; Martín-del-Campo, C.

    2017-01-01

    Highlights: • Methodology based on Monte Carlo simulation. • Sensitivity analysis of Lead Fast Reactor (LFR). • Uncertainty and regression analysis of LFR. • 10% change in the core inlet flow, the response in thermal power change is 0.58%. • 2.5% change in the inlet lead temperature the response is 1.87% in power. - Abstract: The aim of this paper is the sensitivity and uncertainty analysis of a Lead-Cooled Fast Reactor (LFR) based on Monte Carlo simulation of sizes up to 2000. The methodology developed in this work considers the uncertainty of sensitivities and uncertainty of output variables due to a single-input-variable variation. The Advanced Lead fast Reactor European Demonstrator (ALFRED) is analyzed to determine the behavior of the essential parameters due to effects of mass flow and temperature of liquid lead. The ALFRED core mathematical model developed in this work is fully transient, which takes into account the heat transfer in an annular fuel pellet design, the thermo-fluid in the core, and the neutronic processes, which are modeled with point kinetic with feedback fuel temperature and expansion effects. The sensitivity evaluated in terms of the relative standard deviation (RSD) showed that for 10% change in the core inlet flow, the response in thermal power change is 0.58%, and for 2.5% change in the inlet lead temperature is 1.87%. The regression analysis with mass flow rate as the predictor variable showed statistically valid cubic correlations for neutron flux and linear relationship neutron flux as a function of the lead temperature. No statistically valid correlation was observed for the reactivity as a function of the mass flow rate and for the lead temperature. These correlations are useful for the study, analysis, and design of any LFR.

  20. Development of a stand-alone microcomputer based DOE contractor generic radiation worker safety course

    International Nuclear Information System (INIS)

    Klos, D.B.; Gardner, P.R.

    1985-01-01

    Westinghouse Hanford Company (WHC) has developed Computer Based Training (CBT) materials for radiation and industrial safety. First released for general Fast Flux Test Facility in November, 1984. This course has now been taken by nearly 350 people. Completion times for new personnel average around eight hours. The next project undertaken was construction of a Radiation Worker Safety course generic enough for use by all contractors at the Hanford site. The design process of the Hanford site course indicated that the quantity of ''DOE common material'' may be sufficient to warrant consideration of a larger target population. Specifically, the course will be designed to run on an IBM-PC or compatible computer having 256K RAM, a standard IBM color graphics card or equivalent, a color graphics monitor, and two floppy disk drives or one hard disk. The target student population includes those who routinely work in Radiation Areas, especially crafts people. We are not targeting Health Physics personnel, except, possibly, for introductory training, nor are we directing the course toward ''casual'' or escorted workers

  1. The children left to stand alone | Roalkvam | African Journal of AIDS ...

    African Journals Online (AJOL)

    Drawing upon ethnographic fieldwork in Seke, a semi-rural area outside Harare, Zimbabwe, this paper explores the social mechanism behind the seeming invisibility of children left on their own and how this form of 'invisibility' challenges established notions of childhood, parenthood, kinship, and community. It argues that ...

  2. Comparing Memory-Efficient Genome Assemblers on Stand-Alone and Cloud Infrastructures

    KAUST Repository

    Kleftogiannis, Dimitrios A.; Kalnis, Panos; Bajic, Vladimir B.

    2013-01-01

    methodologies, we propose two general assembly strategies that can improve short-read assembly approaches and result in reduction of the memory footprint. Finally, we discuss the possibility of utilizing cloud infrastructures for genome assembly and we comment

  3. An ArcGIS analysis of Stand-alone GPS quality for Road Pricing

    DEFF Research Database (Denmark)

    Zabic, Martina

    2006-01-01

    The paper presents the methods and some of the result maps from a study of GPS quality in relation to road pricing in a dense urban area. Data from 500 cars were colleted over a two-year period in the Copenhagen region (Denmark). The data was analyzed in ArcGIS in order to determine whether the GPS...... quality and reliability is adequate for implementation of a road pricing system. The GPS log files was imported into ArcGIS and analyzed in relation to the digital road network and the density of the high rise areas in order to examine where the high buildings and narrow street canyons causes too many...

  4. Kajian Pemanfaatan Stand Alone Photovoltaic System Untuk Penerangan Jalan Umum Di Pulau Nusa Penida

    Directory of Open Access Journals (Sweden)

    I.W. Yudi Martha Wiguna

    2012-12-01

    Full Text Available   Nusa Penida merupakan sebuah pulau di tenggara pulau Bali dengan jumlah penduduk 47.448 jiwa. Ketersediaan daya pembangkit PLN di pulau Nusa Penida adalah sebesar 3200 kW. Dengan beban puncak sebesar 2530 kW maka cadangan listrik saat ini hanya sebesar 670 kW. Hal itu menyebabkan krisis listrik sangat terasa bagi masyarakat di daerah terpencil seperti di Pulau Nusa Penida. Saat ini salah satu solusi yang memungkinkan adalah mengembangkan sumber energi terbarukan. Di Pulau Nusa Penida sudah dikembangkan PLTS. Bahkan PLTS di Pulau Nusa Penida dikembangkan juga pada sistem penerangan jalan umum. Pada penelitian ini dilakukan analisa teknis dan biaya untuk mengetahui kelayakan Sistem PJU-TS tersebut. Pada analisa teknis dilakukan pengukuran output tegangan dan arus dari PV Panel ke Charger Controller, dari Charger Controller ke baterai dan ke beban. Analisa teknis menghasilkan bahwa penyebab kerusakan baterai karena kapasitas pembangkitan tidak sebanding dengan kebutuhan kapasitas beban PJU-TS. Dengan kapasitas baterai yang terus kecil akan menyebabkan kerusakan pada baterai. Selain itu karena usia baterai yang sudah lama. Analisa biaya dilakukan dengan 3 skenario dengan tingkat IRR yang ingin dicapai sebesar 10, 11, dan 12 %. Dihasilkan harga jual yang pantas untuk energi listrik PJU-TS Nusa Penida berkisar antara Rp.29.194,00 s/d Rp.31.585,00 per kWh.

  5. SAMAC program: the computer support for a stand-alone monitoring and control system

    International Nuclear Information System (INIS)

    Logg, C.A.

    1979-12-01

    The high energy physics experiments at SLAC require constant monitoring and control of the numerous components contained in the particle detection apparatus. This paper describes a basic hardware configuration and operating system which have been designed and implemented to satisfy the monitoring and control requirements of the many different setups used in these high energy physics experiments. It is based on the LSI-11 microprocessor with up to one million words of RAM and EPROM which are interchangeably mappable into the normal LSI-11 RAM/EPROM address space of 28K words. The entire system is modular in hardware and software so that it can easily be tailored to an individual experiment. The human interface is such that little training is required for effective use of the system

  6. Stand-alone and Interdisciplinary Course Design for Engineering Education for Sustainable Development

    DEFF Research Database (Denmark)

    Arsat, M.; Holgaard, Jette Egelund; de Graaff, Erik

    discipline or to fit across programmes. At Aalborg University (AAU), Denmark, which has a long tradition of problem based learning (PBL), a comprehensive sustainability course has been introduced to fit all students not at least across programmes but also across faculties of engineering, humanities...

  7. Battery Storage Technologies for Electrical Applications: Impact in Stand-Alone Photovoltaic Systems

    OpenAIRE

    Daniel Akinyele; Juri Belikov; Yoash Levron

    2017-01-01

    Batteries are promising storage technologies for stationary applications because of their maturity, and the ease with which they are designed and installed compared to other technologies. However, they pose threats to the environment and human health. Several studies have discussed the various battery technologies and applications, but evaluating the environmental impact of batteries in electrical systems remains a gap that requires concerted research efforts. This study first presents an ove...

  8. Analysis and optimization of hybrid excitation permanent magnet synchronous generator for stand-alone power system

    International Nuclear Information System (INIS)

    Wang, Huijun; Qu, Zheng; Tang, Shaofei; Pang, Mingqi; Zhang, Mingju

    2017-01-01

    Highlights: • One novel permanent magnet generator structure has been proposed to reduce voltage regulation ratio. • Finite element method and equivalent circuit methods are both employed to realize rapid generator design. • Design of experiment (DOE) method is used to optimize permanent magnet shape for reduce voltage waveform distortion. • The obtained analysis and experiment results verify the proposed design methods. - Abstract: In this paper, electromagnetic design and permanent magnet shape optimization for permanent magnet synchronous generator with hybrid excitation are investigated. Based on generator structure and principle, design outline is presented for obtaining high efficiency and low voltage fluctuation. In order to realize rapid design, equivalent magnetic circuits for permanent magnet and iron poles are developed. At the same time, finite element analysis is employed. Furthermore, by means of design of experiment (DOE) method, permanent magnet is optimized to reduce voltage waveform distortion. Finally, the validity of proposed design methods is validated by the analytical and experimental results.

  9. X-ray microbeam stand-alone facility for cultured cells irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Sebastian, E-mail: sebastian.bozek@yahoo.com [Jagiellonian University Medical College, Department of Pharmaceutical Biophysics, Krakow (Poland); Bielecki, Jakub; Wiecheć, Anna; Lekki, Janusz; Stachura, Zbigniew; Pogoda, Katarzyna; Lipiec, Ewelina; Tkocz, Konrad; Kwiatek, Wojciech M. [Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow (Poland)

    2017-03-01

    Highlights: • An X-ray microbeam line for irradiation of living cultured cells was constructed. • A step by step explanation of working principles with engineering details, procedures and calculations is presented. • A model of beam and cell interaction is presented. • A method of uniform irradiation of living cells with an exact dose per a cell is presented. • Results of preliminary experiments are presented. - Abstract: The article describes an X-ray microbeam standalone facility dedicated for irradiation of living cultured cells. The article can serve as an advice for such facilities construction, as it begins from engineering details, through mathematical modeling and experimental procedures, ending up with preliminary experimental results and conclusions. The presented system consists of an open type X-ray tube with microfocusing down to about 2 μm, an X-ray focusing system with optical elements arranged in the nested Kirckpatrick-Baez (or Montel) geometry, a sample stand and an optical microscope with a scientific digital CCD camera. For the beam visualisation an X-ray sensitive CCD camera and a spectral detector are used, as well as a scintillator screen combined with the microscope. A method of precise one by one irradiation of previously chosen cells is presented, as well as a fast method of uniform irradiation of a chosen sample area. Mathematical models of beam and cell with calculations of kerma and dose are presented. The experiments on dose-effect relationship, kinetics of DNA double strand breaks repair, as well as micronuclei observation were performed on PC-3 (Prostate Cancer) cultured cells. The cells were seeded and irradiated on Mylar foil, which covered a hole drilled in the Petri dish. DNA lesions were visualised with γ-H2AX marker combined with Alexa Fluor 488 fluorescent dye.

  10. The Small, Stand-Alone Early College: Impact on High School Outcomes

    Science.gov (United States)

    Glennie, Elizabeth; Unlu, Fatih; Furey, Jane

    2016-01-01

    North Carolina's Early College model is the subject of an IES-funded eleven-year longitudinal experimental study that utilized a lottery process to assign early college applicants to either treatment or control groups. This paper presents findings related to high school outcomes. The primary goal of the early college model is to increase the…

  11. The Small, Stand-Alone Early College: Impact on Postsecondary Outcomes

    Science.gov (United States)

    Unlu, Fatih; Furey, Jane

    2016-01-01

    This paper presents results from the longitudinal experimental study conducted on North Carolina's early college model described in an earlier paper. The primary purpose of this paper is to present the impact of the early college model on outcomes related to postsecondary enrollment. The specific research questions driving this study include: (1)…

  12. Stand-alone error characterisation of microwave satellite soil moisture using a Fourier method

    Science.gov (United States)

    Error characterisation of satellite-retrieved soil moisture (SM) is crucial for maximizing their utility in research and applications in hydro-meteorology and climatology. Error characteristics can provide insights for retrieval development and validation, and inform suitable strategies for data fus...

  13. A stand-alone track reconstruction algorithm for the scintillating fibre tracker at the LHCb upgrade

    CERN Multimedia

    Quagliani, Renato

    2017-01-01

    The LHCb upgrade detector project foresees the presence of a scintillating fiber tracker (SciFi) to be used during the LHC Run III, starting in 2020. The instantaneous luminosity will be increased up to $2\\times10^{33}$, five times larger than in Run II and a full software event reconstruction will be performed at the full bunch crossing rate by the trigger. The new running conditions, and the tighter timing constraints in the software trigger, represent a big challenge for track reconstruction. This poster presents the design and performance of a novel algorithm that has been developed to reconstruct track segments using solely hits from the SciFi. This algorithm is crucial for the reconstruction of tracks originating from long-lived particles such as $K_{S}^{0}$ and $\\Lambda$ and allows to greatly enhance the physics potential and capabilities of the LHCb upgrade when compared to its previous implementation.

  14. Comparing Memory-Efficient Genome Assemblers on Stand-Alone and Cloud Infrastructures

    KAUST Repository

    Kleftogiannis, Dimitrios A.

    2013-09-27

    A fundamental problem in bioinformatics is genome assembly. Next-generation sequencing (NGS) technologies produce large volumes of fragmented genome reads, which require large amounts of memory to assemble the complete genome efficiently. With recent improvements in DNA sequencing technologies, it is expected that the memory footprint required for the assembly process will increase dramatically and will emerge as a limiting factor in processing widely available NGS-generated reads. In this report, we compare current memory-efficient techniques for genome assembly with respect to quality, memory consumption and execution time. Our experiments prove that it is possible to generate draft assemblies of reasonable quality on conventional multi-purpose computers with very limited available memory by choosing suitable assembly methods. Our study reveals the minimum memory requirements for different assembly programs even when data volume exceeds memory capacity by orders of magnitude. By combining existing methodologies, we propose two general assembly strategies that can improve short-read assembly approaches and result in reduction of the memory footprint. Finally, we discuss the possibility of utilizing cloud infrastructures for genome assembly and we comment on some findings regarding suitable computational resources for assembly.

  15. Experimental stand-alone self-excited induction generator driven by a diesel motor

    Directory of Open Access Journals (Sweden)

    Mhamdi Taoufik

    2017-12-01

    Full Text Available This paper presents an experimental work to design and size a diesel generator (DG. The basic system is equipped with a 1.5 kW self-excited induction generator (SEIG, a diesel motor (DM, a static voltage compensator (SVC and controllers. A proportional integral controller is used to meet the requirement of the SEIG frequency regulation. A controlled voltage source is performed by using an SVC with a fuzzy controller, which adjusts voltage by varying the amount of the injected reactive power. An experimental set-up is used to identify the SEIG parameters and select the convenient bank of capacitors that minimize the SEIG starting up time and fix the convenient margin of voltage. The system has been tested by simulation using models implemented by Matlab/Simulink software. The simulation results confirm the efficiency of the proposed strategy of voltage regulation. Keywords: Diesel motor, SEIG, SVC, Voltage regulation, Frequency regulation

  16. SSTAR, a Stand-Alone Easy-To-Use Antimicrobial Resistance Gene Predictor.

    Science.gov (United States)

    de Man, Tom J B; Limbago, Brandi M

    2016-01-01

    We present the easy-to-use Sequence Search Tool for Antimicrobial Resistance, SSTAR. It combines a locally executed BLASTN search against a customizable database with an intuitive graphical user interface for identifying antimicrobial resistance (AR) genes from genomic data. Although the database is initially populated from a public repository of acquired resistance determinants (i.e., ARG-ANNOT), it can be customized for particular pathogen groups and resistance mechanisms. For instance, outer membrane porin sequences associated with carbapenem resistance phenotypes can be added, and known intrinsic mechanisms can be included. Unique about this tool is the ability to easily detect putative new alleles and truncated versions of existing AR genes. Variants and potential new alleles are brought to the attention of the user for further investigation. For instance, SSTAR is able to identify modified or truncated versions of porins, which may be of great importance in carbapenemase-negative carbapenem-resistant Enterobacteriaceae. SSTAR is written in Java and is therefore platform independent and compatible with both Windows and Unix operating systems. SSTAR and its manual, which includes a simple installation guide, are freely available from https://github.com/tomdeman-bio/Sequence-Search-Tool-for-Antimicrobial-Resistance-SSTAR-. IMPORTANCE Whole-genome sequencing (WGS) is quickly becoming a routine method for identifying genes associated with antimicrobial resistance (AR). However, for many microbiologists, the use and analysis of WGS data present a substantial challenge. We developed SSTAR, software with a graphical user interface that enables the identification of known AR genes from WGS and has the unique capacity to easily detect new variants of known AR genes, including truncated protein variants. Current software solutions do not notify the user when genes are truncated and, therefore, likely nonfunctional, which makes phenotype predictions less accurate. SSTAR users can apply any AR database of interest as a reference comparator and can manually add genes that impact resistance, even if such genes are not resistance determinants per se (e.g., porins and efflux pumps).

  17. Porous silicon with embedded tritium as a stand-alone prime power source for optoelectronic applications

    International Nuclear Information System (INIS)

    Tam, S.W.

    1997-01-01

    Disclosed is an illumination source comprising a porous silicon having a source of electrons on the surface and/or interstices thereof having a total porosity in the range of from about 50 v/o to about 90 v/o. Also disclosed are a tritiated porous silicon and a photovoltaic device and an illumination source of tritiated porous silicon. 1 fig

  18. Porous silicon with embedded tritium as a stand-alone prime power source for optoelectronic applications

    Science.gov (United States)

    Tam, Shiu-Wing

    1997-01-01

    An illumination source comprising a porous silicon having a source of electrons on the surface and/or interticies thereof having a total porosity in the range of from about 50 v/o to about 90 v/o. Also disclosed are a tritiated porous silicon and a photovoltaic device and an illumination source of tritiated porous silicon.

  19. The Politics of Education: Why Stand-Alone Youth Work Degrees Matter

    Science.gov (United States)

    Bessant, Judith

    2007-01-01

    While the demand in Australia for youth workers is growing, the education of youth workers in universities is being "rationalised" because these institutions have been fiscally squeezed by successive federal governments. What are the consequences for youth workers, young people and society as a whole if the move towards…

  20. Comparing memory-efficient genome assemblers on stand-alone and cloud infrastructures.

    Science.gov (United States)

    Kleftogiannis, Dimitrios; Kalnis, Panos; Bajic, Vladimir B

    2013-01-01

    A fundamental problem in bioinformatics is genome assembly. Next-generation sequencing (NGS) technologies produce large volumes of fragmented genome reads, which require large amounts of memory to assemble the complete genome efficiently. With recent improvements in DNA sequencing technologies, it is expected that the memory footprint required for the assembly process will increase dramatically and will emerge as a limiting factor in processing widely available NGS-generated reads. In this report, we compare current memory-efficient techniques for genome assembly with respect to quality, memory consumption and execution time. Our experiments prove that it is possible to generate draft assemblies of reasonable quality on conventional multi-purpose computers with very limited available memory by choosing suitable assembly methods. Our study reveals the minimum memory requirements for different assembly programs even when data volume exceeds memory capacity by orders of magnitude. By combining existing methodologies, we propose two general assembly strategies that can improve short-read assembly approaches and result in reduction of the memory footprint. Finally, we discuss the possibility of utilizing cloud infrastructures for genome assembly and we comment on some findings regarding suitable computational resources for assembly.

  1. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  2. Control aspects of the Schuchuli Village stand-alone photovoltaic power system

    Science.gov (United States)

    Groumpos, P. P.; Culler, J. E.; Delombard, R.

    1984-11-01

    A photovoltaic power system in an Arizona Indian village was installed. The control subsystem of this photovoltaic power system was analyzed. The four major functions of the control subsystem are: (1) voltage regulation; (2) load management; (3) water pump control; and (4) system protection. The control subsystem functions flowcharts for the control subsystem operation, and a computer program that models the control subsystem are presented.

  3. Bifacial PV cell with reflector for stand-alone mast for sensor powering purposes

    Science.gov (United States)

    Jakobsen, Michael L.; Thorsteinsson, Sune; Poulsen, Peter B.; Riedel, N.; Rødder, Peter M.; Rødder, Kristin

    2017-09-01

    Reflectors to bifacial PV-cells are simulated and prototyped in this work. The aim is to optimize the reflector to specific latitudes, and particularly northern latitudes. Specifically, by using minimum semiconductor area the reflector must be able to deliver the electrical power required at the condition of minimum solar travel above the horizon, worst weather condition etc. We will test a bifacial PV-module with a retroreflector, and compare the output with simulations combined with local solar data.

  4. Maximun power point tracker of photovoltaic s panels for stand alone systems

    International Nuclear Information System (INIS)

    Stoll, R; Manno, R

    2005-01-01

    The low energetic efficiency of photovoltaic s panels is known, in addition, due to the use of linear regulators, which dissipate an important bit of the generated energy, the efficiency of the photovoltaic systems is still smaller.Also, the I-V characteristic curve of the photovoltaic modules depends on the solar radiation and the own temperature; consequently, the maximum power point (Wp) changes permanently.In conclusion, to produce electricity with photovoltaic panels is very expensive. However due to preserve the environment this technology is widely used.With the purpose of optimizing the amount of energy produced by the photovoltaic system, two complementary methods are used.One is the Maximum Power Point Tracker (MPPT) system and the other one is the Solar Tracker system.The objective of this project is to reduce that cost increasing the amount of energy produced by the solar panels using a Maximum Power Point Tracker system.This device consists of a DC/DC buck converter of high performance, controlled by a PIC 16F873 micro controller; which carries out the conversions of the analogical signals of the solar array to digital signals (ADC), the PIC output digital signals to the PWM control of the power FET (DAC), and calculates the Duty Cycle (D) for the point of I-V curve where this product becomes maximum.Measurements for different loads and battery charges were made.With the obtained results, the comparisons with a conventional system were made, a greater cession of energy to the load is observed.The main conclusion of this work is: Using a MPPT device to making work the PV module during the greater possible time near the maximum power point, the efficiency of the photovoltaic systems can be increased

  5. Essays on Housing Markets

    DEFF Research Database (Denmark)

    Bäckman, Claes

    In Denmark and in many countries around the world, housing markets are of considerable importance for households and policy-makers alike. As the boom and bust in the US and Danish housing market so aptly demonstrated, disruptions in the housing market potentially have wide-ranging consequences...... for individual households and for the aggregate economy. Housing is important because we all have to live somewhere, but also because it serves as a considerable source of both wealth and debt. As such, housing market policy can not only create vast benefits for many, but can also have substantial negative...... impacts for all, and should therefore be a topic of major interest for economists and policy makers alike. This Ph.D. thesis, entitled “Essays on Housing Markets”, analyzes the Danish housing market during the 2000s, with a focus on how policy changes affected house prices and how changes in house prices...

  6. The bishops and housing.

    Science.gov (United States)

    Shellabarger, Thomas

    2005-01-01

    According to Catholic social teaching, housing is not a commodity but a human right. To ensure that all people--especially low-income elderly and other vulnerable populations--have access to affordable housing, the church has established a variety of programs, services, and advocacy efforts. Much of this work is based on key concepts: preserving existing housing stock, creating new programs to provide more options for the underserved, empowering residents and communities to deal with housing issues, establishing partnerships to make organizations' efforts more successful, making housing affordable, and ending discrimination in housing. Although church ministries, community groups, the private sector, and other players must work together to find solutions to the housing crisis, federal leadership is essential. Especially with the housing affordability gap growing and the U.S. population aging, the federal government must provide the resources, leadership, and direction for effective housing solutions.

  7. Performance of a reversible heat pump/organic Rankine cycle unit coupled with a passive house to get a positive energy building

    DEFF Research Database (Denmark)

    Dumont, Olivier; Carmo, Carolina; Fontaine, Valentin

    2016-01-01

    This paper presents an innovative technology that can be used to deliver more renewable electricity production than the total electrical consumption of a building while covering the heat demand on a yearly basis. The technology concept uses a heat pump (HP), slightly modified to revert its cycle...... and generate electricity, coupled to a solar thermal collector roof. This reversible HP/organic Rankine cycle unit presents three operating modes: direct heating, HP and organic Rankine cycle. This work focuses on describing the dynamic model of the multi-component system followed by a techno-economic analysis......Wh/year and total electrical consumption of 2318 kWh/year) with a 138.8 m2 solar roof in Denmark....

  8. Situation-Based Housing

    DEFF Research Database (Denmark)

    Duelund Mortensen, Peder

    2011-01-01

    Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen......Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen...

  9. House Price, House Quality and Economic Growth

    NARCIS (Netherlands)

    De Vries, P.; Boelhouwer, P.J.

    2010-01-01

    The literature on housing markets suggest that periods of economic growth are characterised by a demand for better housing quality and increasing prices. The basic principles of the theory are that the short-run price fluctuations occur due to market imperfection, while over the long term, causality

  10. Active house concept versus passive House

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    The passive house concept is the present trend in energy efficient sustainable dwellings. Within the passive house concept every effort is made to minimize the energy use. Substantial savings can be achieved by passive energy systems, especially natural ventilation, summer shading and winter solar

  11. Living in some of the first Danish Passive Houses

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla

    2012-01-01

    The pilot project, named Comfort Houses, aims to show the industry that it is possible to construct traditional Danish houses as passive houses and promote them as comfortable houses. For this to be a success in the future, it is necessary to fulfil the occupants’ wants and needs. This study aims...... to communicate how the occupants of the Comfort Houses experience living in a passive house and illustrate how their behaviour affect the performance of the house. This is done through qualitative interviews with the occupants compared with quantitative measurements of the performance of the Comfort Houses....... A total of 3 residential units have been examined and the results show that the occupants’ everyday lives have changed – some as a result of the architectural and structural solutions, others as a result of the technology integrated in the houses. The study determines the importance of considering...

  12. Financial analysis on the proposed renewable heat incentive for residential houses in the United Kingdom: A case study on the solar thermal system

    International Nuclear Information System (INIS)

    Abu-Bakar, Siti Hawa; Muhammad-Sukki, Firdaus; Ramirez-Iniguez, Roberto; Munir, Abu Bakar; Mohd Yasin, Siti Hajar; Mallick, Tapas Kumar; McLennan, Campbell; Abdul Rahim, Ruzairi

    2014-01-01

    This short communication paper focuses on the renewable heat incentive (RHI) scheme in the United Kingdom (UK); and in particular, on its implication on domestic installations of solar thermal systems (STSs). First, a short review on the STS in the UK is provided. Then, a detailed description of the RHI is discussed. A financial analysis is presented afterwards, analysing the impact of the RHI scheme on the applicants, in terms of the net present value and the internal rate of return. From the financial analysis it has been found that the RHI scheme for domestic installations is only attractive if a longer period of RHI payment, i.e. 17 years, or a higher RHI rate i.e. £0.32 per kW h is implemented. The current proposal from the UK government is not financially viable, and as a result, it may hinder the penetration of domestic solar thermal systems in the residential sector in the UK. - Highlights: • A short review on solar thermal system (STS) is presented. • The renewable heat incentive (RHI) scheme is discussed. • A financial analysis is evaluated under the RHI scheme in the UK. • The analysis indicates the current proposal is not desirable to consumers

  13. Housing Search and Consumption Adjustment,

    Science.gov (United States)

    1980-04-01

    bility have appeared in the literature (Speare et al., 1975; Hanushek and Quigley, 1978; Brummell, 1979). Although differing on specifics, these...divide into two types: formal models of the decision to move (Speare et al., 1975; Hanushek and Quigley, 1978) that recognize housing search as a trans...effort expended in searching for a new unit (Abt, 1978; Hanushek and Quigley, 1978; Cronin, 1978). Geographers refer to residential stress and resistance

  14. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  15. Allegheny County Older Housing

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Older housing can impact the quality of the occupant's health in a number of ways, including lead exposure, housing quality, and factors that may exacerbate...

  16. Housing of Hobson's Choice

    DEFF Research Database (Denmark)

    Vestergaard, Hedvig

    2010-01-01

    This paper looks at policies implemented to improve troubled housing estates during more than two decades. Based on evaluations of implemented programmes and case studies the paper provides a basis for discussing a number of questions: • Why do we have troubled housing estates? • What...... is the definition of troubled housing estates? • Who lives on troubled housing estates? • Who owns and manages the troubled housing estates? • What have been the reasons behind improvement programmes for troubled housing estates? • What kind of improvement programmes have been implemented and with what kind...... of results? • Have improvement programmes changed the position of the estates on the local housing markets? • What are the changes in policies and results? • What are the perspectives for policy initiatives in the field of troubled housing estates?...

  17. Do increases in subsidized housing reduce the incidence of homelessness? Vidence from the low-income housing tax credit

    OpenAIRE

    Jackson, Osborne; Kawano, Laura

    2015-01-01

    We examine the impact of subsidized housing on homelessness using the Low-Income Housing Tax Credit (LIHTC), the largest place-based housing program in the United States. To generate quasi-experimental variation in housing placements, we exploit a discontinuous increase in the amount of tax credits available to projects placed in certain high-poverty neighborhoods. Using data from the U.S. Census and HUD, we find that LIHTC project installation has no significant impact on neighborhood homele...

  18. Essays on local housing and real estate brokerage markets.:Essays on local housing and real estate brokerage markets.

    OpenAIRE

    Helgers, Roel

    2016-01-01

    As noted by the late housing economist John Quigley (1979), housing markets are characterized by a peculiar combination of features, such as durability, spatial fixity and multidimensional heterogeneity. The combination of these features differentiate it from other product markets and it has been shown that they have a non-negligible impact upon market outcomes in housing and real estate brokerage markets. The inherent spatial fixation and the multidimensional heterogeneity of housing units, ...

  19. Radon in houses

    International Nuclear Information System (INIS)

    Toohey, R.E.; Essling, M.A.; Markun, F.

    1985-01-01

    The purpose of this study is to determine the concentrations of 222 Rn and its short-lived daughter products in the air of single-family houses in the midwestern US. During the past year, more than 200 houses were added to the study, resulting in a total of more than 400 houses. So far, results are available for 270 of these houses, equally divided between the Chicago area and Bloomsburg, Pennsylvania. 6 refs

  20. Sea Training at Maritime Academies Oversight. Hearings Before the Ad Hoc Select Subcommittee on Maritime Education and Training of the Committee on Merchant Marine and Fisheries, House of Representatives, Ninety-Sixth Congress, Second Session on Sea Training of United States Merchant Marine Officers and Different Ways of Satisfying This Requirement at the Various Maritime Academies.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. House Committee on Merchant Marine and Fisheries.

    Recorded are minutes of hearings before the House Ad Hoc Select Subcommittee on Maritime Education and Training regarding the sea training of United States Merchant Marine officers. Examined are various approaches to meeting the sea training requirement, especially the options of maritime academy training vessels, sailing on U.S.-flag merchant…

  1. Social Housing in Denmark

    DEFF Research Database (Denmark)

    Vestergaard, Hedvig; Scanlon, Kath J

    2014-01-01

    Social housing is a cornerstone in the Danish welfare society and is accessible for all households. By law, social housing must be rented at cost rents, which are based on historical costs; rents do not respond to market forces. Social housing aims to provide good standard, secure and affordable...... as social initiatives in the existing stock....

  2. Smart Solar Housing Renovation

    NARCIS (Netherlands)

    Ham, M.; Bruijn, de D.M.P.; Vos, S.J.H.; Weijers, K.A.M.; Straver, M.C.W.; Scartezzini, J.L.

    2009-01-01

    After World War II, the demand for houses in the Netherlands was enormous. Large housing construction programs were established in the fifties, sixties and seventies. Nowadays, these houses are facing some societal, economic and technological problems. On the other hand, many of the occupants are

  3. Dutch house price fundamentals

    NARCIS (Netherlands)

    Haffner, M.E.A.; de Vries, P.

    2009-01-01

    This paper discusses house price developments in the Netherlands, specifically focussing on the question whether current house prices in the Dutch owner-occupied market are likely to decrease. We analyse three aspects of the question based on a literature review: (1) whether there is a house price

  4. Homelessness and Housing Insecurity Among Former Prisoners

    Directory of Open Access Journals (Sweden)

    Claire W. Herbert

    2015-11-01

    Full Text Available The United States has experienced dramatic increases in both incarceration rates and the population of insecurely housed or homeless persons since the 1980s. These marginalized populations have strong overlaps, with many people being poor, minority, and from an urban area. That a relationship between homelessness, housing insecurity, and incarceration exists is clear, but the extent and nature of this relationship is not yet adequately understood. We use longitudinal, administrative data on Michigan parolees released in 2003 to examine returning prisoners’ experiences with housing insecurity and homelessness. Our analysis finds relatively low rates of outright homelessness among former prisoners, but very high rates of housing insecurity, much of which is linked to features of community supervision, such as intermediate sanctions, returns to prison, and absconding. We identify risk factors for housing insecurity, including mental illness, substance use, prior incarceration, and homelessness, as well as protective “buffers” against insecurity and homelessness, including earnings and social supports.

  5. Carbon dioxide production in animal houses

    DEFF Research Database (Denmark)

    Pedersen, Søren; Blanes-Vidal, Victoria; Joergensen, H.

    2008-01-01

    cellars are emptied regularly in a four weeks interval. Due to a high and variable carbon dioxide production in deep straw litter houses and houses with indoor storage of manure longer than four weeks, we do not recommend to calculate the ventilation flow based on the carbon dioxide concentration......This article deals with carbon dioxide production from farm animals; more specifically, it addresses the possibilities of using the measured carbon dioxide concentration in animal houses as basis for estimation of ventilation flow (as the ventilation flow is a key parameter of aerial emissions from...... animal houses). The investigations include measurements in respiration chambers and in animal houses, mainly for growing pigs and broilers. Over the last decade a fixed carbon dioxide production of 185 litres per hour per heat production unit, hpu (i.e. 1000 W of the total animal heat production at 20o...

  6. Assisted Housing - Public Housing Authorities - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — Public Housing was established to provide decent and safe rental housing for eligible low-income families, the elderly, and persons with disabilities. Public housing...

  7. Housing and Health: The relationship between housing conditions ...

    African Journals Online (AJOL)

    okanlawon

    2011-10-22

    Oct 22, 2011 ... Housing and Health: The relationship between housing ... The authors in chapter one, deal extensively with historical context of housing and health chronologically ... Housing and Health: Time Again for Public Health Action.

  8. Herd-level risk factors for hock injuries in freestall-housed dairy cows in the northeastern United States and California.

    Science.gov (United States)

    Barrientos, A K; Chapinal, N; Weary, D M; Galo, E; von Keyserlingk, M A G

    2013-06-01

    The aim of this study was to investigate the associations between management and facility design factors and the prevalence of hock injuries in high-producing dairy cows in 76 freestall herds in the northeastern United States (NE-US; Vermont, New York, Pennsylvania) and California (CA). One group of high-production multiparous cows was monitored on each farm, and data on management, facility and stall design, and the conditions of the hocks were collected. Focal cows [n=38 ± 3 (mean ± standard deviation)] were evaluated for hock injuries using a 3-point scale (where 1=healthy and 3=evidently swollen or severe injury). Measures associated with the proportion (logit-transformed) of cows having injuries (score ≥ 2) or severe injuries (score=3) at the univariable level were submitted to multivariable general linear models. In NE-US, overall hock injuries increased with the percentage of stalls with fecal contamination [odds ratio (OR)=1.26; 95% confidence interval (CI)=1.02-1.54, for a 10% increase], and with the use of sawdust as bedding (OR=3.47; CI=1.14-10.62), and decreased with deep bedding (i.e., at least 10 cm depth of any type of bedding; OR=0.05; CI=0.02-0.14), use of sand as bedding (OR=0.06; CI=0.02-0.15), bedding dry matter (DM) ≥ 83.9% (OR=0.08; CI=0.03-0.20), and access to pasture during the dry period (OR=0.17; CI=0.05-0.53). When these variables were submitted to a multivariable model, the presence of deep bedding was the only factor that remained significant, explaining 54% of the variation in overall injuries. Severe hock injuries increased with the use of automatic scrapers (OR=2.29; CI=1.11-4.71) and the percentage of stalls with fecal contamination (OR=1.14; CI=1.00-1.31, for a 10% increase), and decreased with sand bedding (OR=0.22; CI=0.10-0.49), deep bedding (OR=0.24; CI=0.11-0.52), bedding DM ≥ 83.9% (OR=0.28; CI=0.14-0.58), and access to pasture during the dry period (OR=0.42; CI=0.18-0.97). The final multivariable model, which

  9. Inadequate housing in Ghana

    Directory of Open Access Journals (Sweden)

    Franklin Obeng-Odoom

    2011-01-01

    Full Text Available Two themes are evident in housing research in Ghana. One involves the study of how to increase the number of dwellings to correct the overall housing deficit, and the other focuses on how to improve housing for slum dwellers. Between these two extremes, there is relatively little research on why the existing buildings are poorly maintained. This paper is based on a review of existing studies on inadequate housing. It synthesises the evidence on the possible reasons for this neglect, makes a case for better maintenance and analyses possible ways of reversing the problem of inadequate housing.

  10. Moodulmaja Passion House = "Passion House" modular home

    Index Scriptorium Estoniae

    2015-01-01

    Moodulmaja Passion House. Arhitektuuri sihtkapitali innovatsioonipreemia 2013 kvaliteetse disaini ja perspektiivika arendustegevuse oskusliku sidumise eest. Arhitekt Eero Endjärv (Arhitekt11), sisearhitekt Hannelore Kääramees (Arhitekt11)

  11. Housing Data Base for Sustainable Housing Provision

    African Journals Online (AJOL)

    Sultan

    The research employed a mixed method approach by collecting both quantitative and qualitative data which were analysed using descriptive analysis in SPSS. The results are ... critical examination of mass housing design in. Nigeria will show ...

  12. DC Linked Hybrid Generation System with an Energy Storage Device including a Photo-Voltaic Generation and a Gas Engine Cogeneration for Residential Houses

    Science.gov (United States)

    Lung, Chienru; Miyake, Shota; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi; Momose, Toshinari; Hayakawa, Hideki

    For the past few years, a hybrid generation system including solar panel and gas cogeneration is being used for residential houses. Solar panels can generate electronic power at daytime; meanwhile, it cannot generate electronic power at night time. But the power consumption of residential houses usually peaks in the evening. The gas engine cogeneration system can generate electronic power without such a restriction, and it also can generate heat power to warm up house or to produce hot water. In this paper, we propose the solar panel and gas engine co-generation hybrid system with an energy storage device that is combined by dc bus. If a black out occurs, the system still can supply electronic power for special house loads. We propose the control scheme for the system which are related with the charging level of the energy storage device, the voltage of the utility grid which can be applied both grid connected and stand alone operation. Finally, we carried out some experiments to demonstrate the system operation and calculation for loss estimation.

  13. Homelessness and Housing Insecurity Among Former Prisoners.

    OpenAIRE

    Herbert, CW; Morenoff, JD; Harding, DJ

    2015-01-01

    The United States has experienced dramatic increases in both incarceration rates and the population of insecurely housed or homeless persons since the 1980s. These marginalized populations have strong overlaps, with many people being poor, minority, and from an urban area. That a relationship between homelessness, housing insecurity, and incarceration exists is clear, but the extent and nature of this relationship is not yet adequately understood. We use longitudinal, administrative data on M...

  14. Mexico Financial Sector Assessment Program : Housing Finance

    OpenAIRE

    World Bank Group; International Finance Corporation

    2016-01-01

    Housing needs are high in Mexico despite quantitative progress in the last 10 years.Global data hide mismatches between housing demand and supply. First, urban growth relied for a long time on a pattern of urban sprawl, with mass-scale developments of individual units were built outside cities where land is affordable, but far from jobs and services and with related high transportation cos...

  15. Housing Instability and Children's Health Insurance Gaps.

    Science.gov (United States)

    Carroll, Anne; Corman, Hope; Curtis, Marah A; Noonan, Kelly; Reichman, Nancy E

    To assess the extent to which housing instability is associated with gaps in health insurance coverage of preschool-age children. Secondary analysis of data from the Early Childhood Longitudinal Study-Birth Cohort, a nationally representative study of children born in the United States in 2001, was conducted to investigate associations between unstable housing-homelessness, multiple moves, or living with others and not paying rent-and children's subsequent health insurance gaps. Logistic regression was used to adjust for potentially confounding factors. Ten percent of children were unstably housed at age 2, and 11% had a gap in health insurance between ages 2 and 4. Unstably housed children were more likely to have gaps in insurance compared to stably housed children (16% vs 10%). Controlling for potentially confounding factors, the odds of a child insurance gap were significantly higher in unstably housed families than in stably housed families (adjusted odds ratio 1.27; 95% confidence interval 1.01-1.61). The association was similar in alternative model specifications. In a US nationally representative birth cohort, children who were unstably housed at age 2 were at higher risk, compared to their stably housed counterparts, of experiencing health insurance gaps between ages 2 and 4 years. The findings from this study suggest that policy efforts to delink health insurance renewal processes from mailing addresses, and potentially routine screenings for housing instability as well as referrals to appropriate resources by pediatricians, would help unstably housed children maintain health insurance. Copyright © 2017 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  16. 24 CFR 990.155 - Addition and deletion of units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Addition and deletion of units. 990.155 Section 990.155 Housing and Urban Development Regulations Relating to Housing and Urban...; Computation of Eligible Unit Months § 990.155 Addition and deletion of units. (a) Changes in public housing...

  17. 24 CFR 8.27 - Occupancy of accessible dwelling units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Occupancy of accessible dwelling units. 8.27 Section 8.27 Housing and Urban Development Office of the Secretary, Department of Housing... accessible dwelling units. (a) Owners and managers of multifamily housing projects having accessible units...

  18. Multifamily Housing Rehabilitation Process Improvements

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, Marshall L. [Partnership for Home Innovation, Upper Marlboro, MD (United States); Francisco, Abby [Partnership for Home Innovation, Upper Marlboro, MD (United States); Roberts, Sydney G. [Partnership for Home Innovation, Upper Marlboro, MD (United States)

    2016-03-01

    Rea Ventures Group, LLC, (Rea Ventures) partnered with Southface Energy Institute (Southface) on the rehabilitation of 418 low-income rental multifamily apartments located at 14 different properties in Georgia (Climate Zones 2-4). These 22-year old, individually-metered units were arranged in rowhouse or townhouse style units. Rehabilitation plans were developed using a process prescribed by the US Department of Agriculture (USDA) Rural Development program, who partially funded the building upgrades. The USDA is responsible for building, upgrading, and subsidizing housing in rural areas nationwide. In 2012, over $100 million was allocated in grants and loans. Due to the unique financing mechanism as well as long-term ownership requirements, property owners are especially motivated to invest in upgrades that will increase durability and tenant retention. These buildings represent a large stock of rural affordable housing that have the potential for significant energy and cost savings for property owners and tenants. Southface analyzed the energy upgrade potential of one stereotypical property in the Rea Ventures portfolio. This study will provide insight into the most cost-effective, implementable energy efficiency and durability upgrades for this age multifamily housing, having an enormous impact not only on the portfolio of Rea Ventures but on the vast USDA and larger Federal portfolio. Additionally, Southface will identify gaps in the current capital needs assessment process, examine available audit and simulation tools and protocols, and evaluate additional auditor training or certification needs.

  19. Social Impacts of the Marking Scheme in Public Housing in Hong Kong

    Science.gov (United States)

    Yau, Yung

    2012-01-01

    To improve environmental hygiene in public housing estates in Hong Kong, the Housing Department launched the Marking Scheme for Tenancy Enforcement in Public Housing Estates in 2003. The marking scheme operates as a penalty-point system where sitting tenants will be expelled from their public housing units if they receive penalty points up to a…

  20. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)