WorldWideScience

Sample records for staging system imaging

  1. MR imaging for staging of cervical carcinoma: Update

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk; Kim, Dong Won [Dong A University Hospital, Busan(Korea, Republic of)

    2017-08-15

    Uterine cervical cancer is globally the third most common cancer among women, and shows high mortality with invasive cervical carcinoma. Early detection of the disease, its correct staging, and treatment are therefore of great importance. The staging system updated in 2009 by the International Federation of Gynecology and Obstetrics (FIGO), is commonly used for planning the treatment. However, there are significant inaccuracies in the FIGO staging system. Accurate tumor staging is very important to decide the treatment strategy. Although not included in the staging system, magnetic resonance (MR) imaging is a valuable tool for local staging of the disease, and is useful in assessing the spread of the tumor and metastatic lymph nodes, thereby becoming a more accurate substitute for clinical staging of cervical carcinoma. In addition, it is capable of assessing the disease response to surgery or chemoradiation. This review briefly describes the role of MR imaging and the basic MR scanning protocol in evaluating cervical carcinoma. The MR findings with staging, and MR evaluation of treatment response, are further addressed.

  2. Imaging and staging of haemophilic arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Jelbert, A.; Vaidya, S. [Radiology Department, Barts and The London NHS trust, London (United Kingdom); Fotiadis, N., E-mail: nicos.fotiadis@bartsandthelondon.nhs.u [Radiology Department, Barts and The London NHS trust, London (United Kingdom)

    2009-11-15

    Arthropathy is one of the most disabling consequences of haemophilia. The management of this condition has been revolutionized by the introduction of prophylactic treatment with clotting factor replacements. In order for benefits of this treatment to be monitored, the severity of any joint disease needs to be accurately assessed. Diagnostic imaging is used to objectively evaluate haemophilic arthropathy (HA). There are several established scoring systems for grading HA based on conventional radiography and magnetic resonance imaging (MRI). In this review the role of the different imaging methods in the evaluation of HA are discussed, the established staging systems are presented, and an explanation of why MRI is becoming the primary method of joint imaging in HA is provided.

  3. Imaging and staging of haemophilic arthropathy

    International Nuclear Information System (INIS)

    Jelbert, A.; Vaidya, S.; Fotiadis, N.

    2009-01-01

    Arthropathy is one of the most disabling consequences of haemophilia. The management of this condition has been revolutionized by the introduction of prophylactic treatment with clotting factor replacements. In order for benefits of this treatment to be monitored, the severity of any joint disease needs to be accurately assessed. Diagnostic imaging is used to objectively evaluate haemophilic arthropathy (HA). There are several established scoring systems for grading HA based on conventional radiography and magnetic resonance imaging (MRI). In this review the role of the different imaging methods in the evaluation of HA are discussed, the established staging systems are presented, and an explanation of why MRI is becoming the primary method of joint imaging in HA is provided.

  4. Diagnostic imaging in the staging of gynecologic cancers

    International Nuclear Information System (INIS)

    Forstner, R.; Graf, A.

    1999-01-01

    The prognosis in patients with gynecologic cancers depends not only on the stage but also on a wide spectrum of other findings. Cross-sectional imaging modalities, including sonography, CT and MRI, have increasingly been used for optimal treatment planning in gynecologic cancers. Their staging criteria are based on the well-established FIGO staging system. CT and MRI compete with sonography, which plays a pivotal role in the valuation of the female pelvis. This paper reviews the role of sonography, CT and MRI in the staging of gynecologic malignancies. It puts the emphasis on MRI, which has been established as imaging modality of choice in the preoperative evaluation of cervical and endometrial cancer, and which seems slightly superior to CT in the staging of ovarian cancer. (orig.) [de

  5. Avascular necrosis of the femoral head; Staging by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Takatori, Yoshio; Ninomiya, Setsuo; Sasaki, Yasuhito [Tokyo Univ. (Japan). Faculty of Medicine

    1993-03-01

    Magnetic resonance (MR) images and conventional radiographs were compared in 142 hips with avascular necrosis, and a staging system for the disease based on MR imaging was developed. MR images were classified into three patterns: a band of low signal intensity (class I); an area of low signal intensity with internal spot(s) of high signal (class II); and an area of low signal intensity without internal spots of high signal (class III). Most MR class I lesions were in radiographic stage I (normal) or II (sclerotic or cystic changes without collapse). Most MR class II lesions were in radiographic stage III (segmental collapse), and most MR class III lesions were in stage III or IV (secondary degenerative changes). The MR image classification was closely correlated with radiographic staging (p<0.01, using [chi] square test). We considered that this classification closely reflected the different stages of the disease according to the histopathology of the bone marrow. (author).

  6. Multi-Stage System for Automatic Target Recognition

    Science.gov (United States)

    Chao, Tien-Hsin; Lu, Thomas T.; Ye, David; Edens, Weston; Johnson, Oliver

    2010-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feedforward back-propagation neural network (NN) is then trained to classify each feature vector and to remove false positives. The system parameter optimizations process has been developed to adapt to various targets and datasets. The objective was to design an efficient computer vision system that can learn to detect multiple targets in large images with unknown backgrounds. Because the target size is small relative to the image size in this problem, there are many regions of the image that could potentially contain the target. A cursory analysis of every region can be computationally efficient, but may yield too many false positives. On the other hand, a detailed analysis of every region can yield better results, but may be computationally inefficient. The multi-stage ATR system was designed to achieve an optimal balance between accuracy and computational efficiency by incorporating both models. The detection stage first identifies potential ROIs where the target may be present by performing a fast Fourier domain OT-MACH filter-based correlation. Because threshold for this stage is chosen with the goal of detecting all true positives, a number of false positives are also detected as ROIs. The verification stage then transforms the regions of interest into feature space, and eliminates false positives using an

  7. Design of nonimaging concentrators as second stages in tandem with image-forming first-stage concentrators

    Science.gov (United States)

    Winston, R.; Welford, W. T.

    1980-02-01

    The paper discusses the paraboloidal mirror as a tracking solar concentrator, fitting a nonimaging second stage to the paraboloidal mirror, other image-forming systems as first stages, and tracking systems in two-dimensional geometry. Because of inherent aberrations, the paraboloidal mirror cannot achieve the thermodynamic limit. It is shown how paraboloidal mirrors of short focal ratio and similar systems can have their flux concentration enhanced to near the thermodynamic limit by the addition of nonimaging compound elliptical concentrators.

  8. Design of nonimaging concentrators as second stages in tandem with image-forming first-stage concentrators

    Science.gov (United States)

    Winston, R.; Welford, W. T.

    1980-01-01

    The paper discusses the paraboloidal mirror as a tracking solar concentrator, fitting a nonimaging second stage to the paraboloidal mirror, other image-forming systems as first stages, and tracking systems in two-dimensional geometry. Because of inherent aberrations, the paraboloidal mirror cannot achieve the thermodynamic limit. It is shown how paraboloidal mirrors of short focal ratio and similar systems can have their flux concentration enhanced to near the thermodynamic limit by the addition of nonimaging compound elliptical concentrators.

  9. Breast cancer staging with MR imaging

    International Nuclear Information System (INIS)

    Smathers, R.L.; D'Amelio, F.; Stockdale, F.

    1989-01-01

    Forty-three patients with biopsy-proved breast cancer underwent MR staging of the cervicothoracic spine, lumbosacral spine, liver, and thorax. In all cases, these findings have been compared with the results of clinical staging, laboratory tests, chest radiography, and radionuclide bone scanning. MR imaging was a valuable staging tool for patients with more than minimal breast cancer and indications for radionuclide bone scanning. MR imaging had the greatest clinical importance when it identified thoracic soft-tissue abnormalities, including axillary., lateral thoracic, supraclavicular, and mediastinal lymphadenopathy. The coronal and sagittal views were very valuable for detection of chest wall invasion, sternal involvement, and internal mammary adenopathy. Negative MR staging clinically reassured patients that aggressive local therapy bad curative potential. Positive MR staging avoided inappropriate aggressive local therapy and mastectomy. MR imaging can be recommended for improved breast cancer staging in patients with newly diagnosed breast cancer who have more than minimal disease

  10. Design of an Image-Servo Mask Alignment System Using Dual CCDs with an XXY Stage

    Directory of Open Access Journals (Sweden)

    Chih-Jer Lin

    2016-02-01

    Full Text Available Mask alignment of photolithography technology is used in many applications, such as micro electro mechanical systems’ semiconductor process, printed circuits board, and flat panel display. As the dimensions of the product are getting smaller and smaller, the automatic mask alignment of photolithography is becoming more and more important. The traditional stacked XY-Θz stage is heavy and it has cumulative flatness errors due to its stacked assembly mechanism. The XXY stage has smaller cumulative error due to its coplanar design and it can move faster than the traditional XY-Θz stage. However, the relationship between the XXY stage’s movement and the commands of the three motors is difficult to compute, because the movements of the three motors on the same plane are coupling. Therefore, an artificial neural network is studied to establish a nonlinear mapping from the desired position and orientation of the stage to three motors’ commands. Further, this paper proposes an image-servo automatic mask alignment system, which consists of a coplanar XXY stage, dual GIGA-E CCDs with lens and a programmable automatic controller (PAC. Before preforming the compensation, a self-developed visual-servo provides the positioning information which is obtained from the image processing and pattern recognition according to the specified fiducial marks. To obtain better precision, two methods including the center of gravity method and the generalize Hough Transformation are studied to correct the shift positioning error.

  11. Magnetic resonance imaging in the staging of renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kishi, Hiroichi; Umeda, Takashi; Niijima, Tadao; Yashiro, Naobumi; Kawabe, Kazuki

    1987-07-01

    Eighteen patients with renal neoplasm underwent magnetic resonance imaging (MRI) using a 1.5 Tesla superconducting magnetic system and spin echo images were obtained by quick scan technique under holding breath. MR images were interpreted independently of the computerized tomography (CT) findings. The preoperative stagings of the 18 renal carcinomas, as judged by MRI, were compared with those obtained at laparotomy. The anatomic staging was correctly performed by MRI in 13 patients (72 %). In the patients who had intrarenal small tumor with normal renal contour, MRI demonstrated a solid mass clearly distinguishable from surrounding renal parenchyma using the paramagnetic contrast agent (gadolinium-DTPA). When compared with results of evaluation by CT in staging, MRI appeared to have several advantages in determination of whole mass; the detection of tumor thrombus into renal vein and inferior vena cava; and the evaluation of direct tumor invasion of adjacent organs. MRI should play an important role in the staging of renal cell carcinoma.

  12. Magnetic resonance imaging in the staging of renal cell carcinoma

    International Nuclear Information System (INIS)

    Kishi, Hiroichi; Umeda, Takashi; Niijima, Tadao; Yashiro, Naobumi; Kawabe, Kazuki

    1987-01-01

    Eighteen patients with renal neoplasm underwent magnetic resonance imaging (MRI) using a 1.5 Tesla superconducting magnetic system and spin echo images were obtained by quick scan technique under holding breath. MR images were interpreted independently of the computerized tomography (CT) findings. The preoperative stagings of the 18 renal carcinomas, as judged by MRI, were compared with those obtained at laparotomy. The anatomic staging was correctly performed by MRI in 13 patients (72 %). In the patients who had intrarenal small tumor with normal renal contour, MRI demonstrated a solid mass clearly distinguishable from surrounding renal parenchyma using the paramagnetic contrast agent (gadolinium-DTPA). When compared with results of evaluation by CT in staging, MRI appeared to have several advantages in determination of whole mass; the detection of tumor thrombus into renal vein and inferior vena cava; and the evaluation of direct tumor invasion of adjacent organs. MRI should play an important role in the staging of renal cell carcinoma. (author)

  13. Magnetic Resonance Imaging Features of the Nigrostriatal System: Biomarkers of Parkinson’s Disease Stages?

    Science.gov (United States)

    Hopes, Lucie; Grolez, Guillaume; Moreau, Caroline; Lopes, Renaud; Ryckewaert, Gilles; Carrière, Nicolas; Auger, Florent; Laloux, Charlotte; Petrault, Maud; Devedjian, Jean-Christophe; Bordet, Regis; Defebvre, Luc; Jissendi, Patrice; Delmaire, Christine; Devos, David

    2016-01-01

    Introduction Magnetic resonance imaging (MRI) can be used to identify biomarkers in Parkinson’s disease (PD); R2* values reflect iron content related to high levels of oxidative stress, whereas volume and/or shape changes reflect neuronal death. We sought to assess iron overload in the nigrostriatal system and characterize its relationship with focal and overall atrophy of the striatum in the pivotal stages of PD. Methods Twenty controls and 70 PD patients at different disease stages (untreated de novo patients, treated early-stage patients and advanced-stage patients with L-dopa-related motor complications) were included in the study. We determined the R2* values in the substantia nigra, putamen and caudate nucleus, together with striatal volume and shape analysis. We also measured R2* in an acute MPTP mouse model and in a longitudinal follow-up two years later in the early-stage PD patients. Results The R2* values in the substantia nigra, putamen and caudate nucleus were significantly higher in de novo PD patients than in controls. Early-stage patients displayed significantly higher R2* values in the substantia nigra (with changes in striatal shape), relative to de novo patients. Measurements after a two-year follow-up in early-stage patients and characterization of the acute MPTP mouse model confirmed that R2* changed rapidly with disease progression. Advanced-stage patients displayed significant atrophy of striatum, relative to earlier disease stages. Conclusion Each pivotal stage in PD appears to be characterized by putative nigrostriatal MRI biomarkers: iron overload at the de novo stage, striatal shape changes at early-stage disease and generalized striatal atrophy at advanced disease. PMID:27035571

  14. MR staging of pelvic endometriosis. Role of fat-suppression T1-weighted images

    International Nuclear Information System (INIS)

    Oishi-Tanaka, Yumiko; Itai, Yuji; Anno, Izumi; Matsumoto, Kunihiko; Ebihara, Reiko; Nishida, Masato

    1996-01-01

    We examined whether MR can determine the stage of endometriosis according to the scoring system established and revised by the American Fertility Society (r-AFS), a system which is widely used by gynecologists. We also studied the utility of fat suppression T 1 -weighted images in improving accuracy. Seventeen patients with endometriosis examined by conventional MR were included in this study. All the patients had surgically proved stage III or IV disease. We determined the stage by MR using the following criteria according to the r-AFS system: adnexal masses without normal ovarian tissue were considered deep ovarian lesions, while those with normal tissue were considered superficial. A lack of fat between the lesion and surrounding structures was considered a dense adhesion, and hyperintense spots were considered peritoneal implants. The MR scores of patients with and without fat suppression were correlated with the surgical scores. MR staging corresponded to surgical staging in 15 of the 17 patients. In eight patients, peritoneal implants of less than 1.5 cm were depicted only by fat-suppression images. However, these lesions did not change the score significantly. MR imaging could determine the stage in advanced endometriosis. Fat-suppression could highlight smaller implants. These tiny lesions had little clinical meaning in these advanced cases; however, the clinical value of this technique should be evaluated in milder disease. (author)

  15. Uterine cervical cancer. Preoperative staging with magnetic resonance imaging; Zervixkarzinom. Praeoperatives Staging mittels Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Hamm, B. [Charite-Universitaetsmedizin Berlin, Campus Charite Mitte, Klinik fuer Radiologie, Berlin (Germany)

    2011-07-15

    The treatment of uterine cervical carcinoma is largely dependent on the tumor stage. Despite significant inaccuracies in the clinical examination, uterine cervical cancer remains the only gynecological form of cancer still largely staged according to clinical findings. Although imaging is still not included in the staging the recently published revised FIGO (Federation International de Gynecologie et d'Obstetrique) system encourages the use of modern cross-sectional imaging (magnetic resonance imaging MRI and computed tomography CT). Due to its high soft tissue contrast MRI allows excellent non-invasive assessment of the cervix with direct tumor delineation as well as assessment of the prognosis based on morphological factors. Studies in the literature report an accuracy of 93% for MRI in the preoperative assessment of tumor size and in the differentiation of operable from advanced cervical cancer. Therefore MRI is considered to be the optimal modality for diagnostic evaluation starting from FIGO stage IB1, for radiation therapy planning, and for exclusion of recurrence in follow-up. In this paper we give an overview of the role of magnetic resonance imaging in preoperative staging of uterine cervical cancer. (orig.) [German] Die Therapieplanung beim Zervixkarzinom ist weitgehend von der Stadieneinteilung nach FIGO (Federation International de Gynecologie et d'Obstetrique) abhaengig, die trotz erheblicher Ungenauigkeiten bei der klinischen Stadieneinteilung weiterhin aufgrund klinischer Untersuchungsbefunde erfolgt. Obwohl bildgebende Verfahren nach wie vor fuer die Stadieneinteilung nicht vorgesehen sind, wird im kuerzlich erschienen revidierten Stagingsystem der FIGO zum ersten Mal die Verwendung moderner Schnittbilddiagnostik (MRT und CT) befuerwortet. Die MRT ermoeglicht dank ihres hohen Weichteilkontrasts ein ausgezeichnetes nichtinvasives Staging des Zervixkarzinoms mit direkter Tumordarstellung sowie einer Prognoseabschaetzung anhand

  16. MR staging of pelvic endometriosis. Role of fat-suppression T{sub 1}-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Oishi-Tanaka, Yumiko; Itai, Yuji; Anno, Izumi; Matsumoto, Kunihiko; Ebihara, Reiko; Nishida, Masato [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1996-05-01

    We examined whether MR can determine the stage of endometriosis according to the scoring system established and revised by the American Fertility Society (r-AFS), a system which is widely used by gynecologists. We also studied the utility of fat suppression T{sub 1}-weighted images in improving accuracy. Seventeen patients with endometriosis examined by conventional MR were included in this study. All the patients had surgically proved stage III or IV disease. We determined the stage by MR using the following criteria according to the r-AFS system: adnexal masses without normal ovarian tissue were considered deep ovarian lesions, while those with normal tissue were considered superficial. A lack of fat between the lesion and surrounding structures was considered a dense adhesion, and hyperintense spots were considered peritoneal implants. The MR scores of patients with and without fat suppression were correlated with the surgical scores. MR staging corresponded to surgical staging in 15 of the 17 patients. In eight patients, peritoneal implants of less than 1.5 cm were depicted only by fat-suppression images. However, these lesions did not change the score significantly. MR imaging could determine the stage in advanced endometriosis. Fat-suppression could highlight smaller implants. These tiny lesions had little clinical meaning in these advanced cases; however, the clinical value of this technique should be evaluated in milder disease. (author)

  17. Prognostic factors of nasopharynx tumors investigated by MR imaging and the value of MR imaging in the newly published TNM staging

    International Nuclear Information System (INIS)

    Sakata, Koh-ichi; Hareyama, Masato; Tamakawa, Mituharu; Oouchi, Atushi; Sido, Mitsuo; Nagakura, Hisayasu; Akiba, Hidenari; Koito, Kazumitsu; Himi, Tetsuo; Asakura, Kohji

    1999-01-01

    Purpose: To examine the usefulness of MR imaging for predicting local control of nasopharyngeal carcinoma (NPC) and the value of MR imaging in the newly published fifth edition of the TNM classification. Methods and Materials: We studied 29 patients with NPC with MR imaging and CT before and after treatment. Staging was done according to the fourth and newly published fifth editions of the International Union Against Cancer (UICC) staging system. The radiotherapy protocol was designed to deliver 66 to 68 Gy to the primary tumor and clinically involved nodes. Results: MR proved better than CT at identifying obliteration of the pharyngobasilar fascia, invasion of the sinus of Morgagni, through which the cartilaginous portion of the eustachian tube and the levator veli palatini muscle pass, invasion of the skull base, and metastases to lymph nodes in the carotid and retropharyngeal spaces. All seven patients without invasion of the pharyngobasilar fascia had local control. The local control rates of patients with invasion of the skull base were not good (60 to 73%). There was no apparent relationship between tumor volume determined by T1-weighted MR images and local control when the tumor volume was more than 20 cc. The newly published N staging system appears to successfully identify the high-risk group for distant metastasis as N3. In our series, four of five patients with N3 disease developed distant metastases. Conclusion: Deep infiltration of the tumor is a more important prognostic factor in NPC than tumor volume. Since the newly published T staging system requires a search for tumor invasion into soft tissue such as parapharyngeal space and bony structures, MR imaging may be indispensable for the newly published NPC staging system

  18. Imaging and detection of early stage dental caries with an all-optical photoacoustic microscope

    International Nuclear Information System (INIS)

    Hughes, D A; Kirk, K J; Sampathkumar, A; Longbottom, C

    2015-01-01

    Tooth decay, at its earliest stages, manifests itself as small, white, subsurface lesions in the enamel. Current methods for detection in the dental clinic are visual and tactile investigations, and bite-wing X-ray radiographs. These techniques suffer from poor sensitivity and specificity at the earliest (and reversible) stages of the disease due to the small size (<100μm) of the lesion. A fine-resolution (600 nm) ultra-broadband (200 MHz) all-optical photoacoustic microscopy system was is used to image the early signs of tooth decay. Ex-vivo tooth samples exhibiting white spot lesions were scanned and were found to generate a larger (one order of magnitude) photoacoustic (PA) signal in the lesion regions compared to healthy enamel. The high contrast in the PA images potentially allows lesions to be imaged and measured at a much earlier stage than current clinical techniques allow. PA images were cross referenced with histology photographs to validate our experimental results. Our PA system provides a noncontact method for early detection of white-spot lesions with a high detection bandwidth that offers advantages over previously demonstrated ultrasound methods. The technique provides the sensing depth of an ultrasound system, but with the spatial resolution of an optical system

  19. Magnetic resonance imaging of the active second stage of labour: Proof of principle

    International Nuclear Information System (INIS)

    Guettler, F.V.; Heinrich, A.; Rump, J.; Bucourt, M. de; Hamm, B.; Teichgraeber, U.K.; Schnackenburg, B.; Bamberg, C.

    2012-01-01

    To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible. Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging. To monitor the birth status during image acquisition, an MR-compatible wireless cardiotocography (CTG) system was built. Single-shot sequence parameters were optimised to compensate motion artefacts during labour. Safety requirements to monitor the birth process under real-time MR imaging were met. High-resolution MR images were acquired immediately before and after delivery. In one patient, TSE single-shot cinematic sequences of the active second stage of labour were obtained. All sequences were adapted to tolerate movement of the mother and infant, as well as residual noise from the CTG. Furthermore, the MR imaging during labour showed only minor image artefacts. CTG-monitored acquisition of MRI series during the active second stage of delivery is feasible. Image quality should allow various further studies to improve models for birth simulation as well as potential investigation of obstructed labour and obstetric complications. (orig.)

  20. Clinical stage T1c prostate cancer: evaluation with endorectal MR imaging and MR spectroscopic imaging.

    Science.gov (United States)

    Zhang, Jingbo; Hricak, Hedvig; Shukla-Dave, Amita; Akin, Oguz; Ishill, Nicole M; Carlino, Lauren J; Reuter, Victor E; Eastham, James A

    2009-11-01

    To assess the diagnostic accuracy of endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for prediction of the pathologic stage of prostate cancer and the presence of clinically nonimportant disease in patients with clinical stage T1c prostate cancer. The institutional review board approved-and waived the informed patient consent requirement for-this HIPAA-compliant study involving 158 patients (median age, 58 years; age range, 40-76 years) who had clinical stage T1c prostate cancer, had not been treated preoperatively, and underwent combined 1.5-T endorectal MR imaging-MR spectroscopic imaging between January 2003 and March 2004 before undergoing radical prostatectomy. On the MR images and combined endorectal MR-MR spectroscopic images, two radiologists retrospectively and independently rated the likelihood of cancer in 12 prostate regions and the likelihoods of extracapsular extension (ECE), seminal vesicle invasion (SVI), and adjacent organ invasion by using a five-point scale, and they determined the probability of clinically nonimportant prostate cancer by using a four-point scale. Whole-mount step-section pathology maps were used for imaging-pathologic analysis correlation. Receiver operating characteristic curves were constructed and areas under the curves (AUCs) were estimated nonparametrically for assessment of reader accuracy. At surgical-pathologic analysis, one (0.6%) patient had no cancer; 124 (78%) patients, organ-confined (stage pT2) disease; 29 (18%) patients, ECE (stage pT3a); two (1%) patients, SVI (stage pT3b); and two (1%) patients, bladder neck invasion (stage pT4). Forty-six (29%) patients had a total tumor volume of less than 0.5 cm(3). With combined MR imaging-MR spectroscopic imaging, the two readers achieved 80% accuracy in disease staging and AUCs of 0.62 and 0.71 for the prediction of clinically nonimportant cancer. Clinical stage T1c prostate cancers are heterogeneous in pathologic stage and volume. MR imaging may

  1. Imaging and detection of early stage dental caries with an all-optical photoacoustic microscope

    Science.gov (United States)

    Hughes, D. A.; Sampathkumar, A.; Longbottom, C.; Kirk, K. J.

    2015-01-01

    Tooth decay, at its earliest stages, manifests itself as small, white, subsurface lesions in the enamel. Current methods for detection in the dental clinic are visual and tactile investigations, and bite-wing X-ray radiographs. These techniques suffer from poor sensitivity and specificity at the earliest (and reversible) stages of the disease due to the small size (tooth decay. Ex-vivo tooth samples exhibiting white spot lesions were scanned and were found to generate a larger (one order of magnitude) photoacoustic (PA) signal in the lesion regions compared to healthy enamel. The high contrast in the PA images potentially allows lesions to be imaged and measured at a much earlier stage than current clinical techniques allow. PA images were cross referenced with histology photographs to validate our experimental results. Our PA system provides a noncontact method for early detection of white-spot lesions with a high detection bandwidth that offers advantages over previously demonstrated ultrasound methods. The technique provides the sensing depth of an ultrasound system, but with the spatial resolution of an optical system.

  2. Invasive cervical carcinoma (stage IB-IIB): assessment with MR imaging

    International Nuclear Information System (INIS)

    Sironi, S.; Del Maschio, A.; Belloni, C.; Taccagni, L.

    1990-01-01

    In patients with cervical carcinoma the selection of the optimal therapy depends on the precise preoperative assessment of the extent of disease. Currently, decisions regarding the management of these patients are made on the basis of clinical (FIGO) staging that has 50% mean error rate. To investigate the value of MR imaging in staging patients with invasive cervical cancer, we performed 25 MR examinations on 23 patients with histologic diagnosis of cervical cancer. All patients were clinically considered as having stage IB or IIB disease and underwent radical hysterectomy, providing specimens for pathologic correlation. The overall accuracy of MR imaging in staging cervical carcinoma (stage IB-IIB) was 78.1%. MR imaging seems to be the most reliable preoperative modality for staging invasive cervical cancer

  3. Scanning Terahertz Heterodyne Imaging Systems

    Science.gov (United States)

    Siegel, Peter; Dengler, Robert

    2007-01-01

    Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

  4. Dual modality CT/PET imaging in lung cancer staging

    International Nuclear Information System (INIS)

    Diaz, Gabriel A.

    2005-01-01

    Purpose: To compare the diagnostic capability of PET-HCT image fusion and helical computed tomography (HCT) for nodal and distant metastases detection in patients with lung cancer. Material and methods: Between February, 2003 and March, 2004 sixty-six consecutive lung cancer patients (45 men and 21 women, mean ages: 63 years old, range: 38 to 96 years old) who underwent HCT and PET-HCT fusion imaging were evaluated retrospectively. All patients had histological confirmation of lung cancer and a definitive diagnosis established on the basis of pathology results and/or clinical follow-up. Results: For global nodal staging (hilar and mediastinal) HCT showed a sensitivity, specificity, positive predictive value and negative predictive value of 72%, 47%, 62% and 58% respectively, versus 94%, 77%, 83% and 92% corresponding to PET-HCT examination. For assessment of advanced nodal stage (N3) PET-HCT showed values of 92%, 100%, 100% and 98% respectively. For detection of distant metastasis, HCT alone had values of 67%, 93%, 84% and 83% respectively versus 100%, 98%, 96% and 100% for the PET-HCT fusion imaging. In 20 (30%) patients under-staged or over-staged on the basis of HCT results, PET-HCT allowed accurate staging. Conclusions: PET-HCT fusion imaging was more effective than HCT alone for nodal and distant metastasis detection and oncology staging. (author)

  5. Magnetic resonance imaging of urinary bladder carcinoma: tumor staging and gadolinium contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Doringer, E.; Joos, H.; Forstner, R.; Schmoller, H.

    1992-01-01

    Forty-nine patients with urinary bladder carcinomas underwent pre-operative examinations using magnetic resonance (MR) imaging. The results of the MR examinations were correlated with the clinical-pathological findings following transurethral resection (TUR) and bimanual palpation (n = 47) or radical cystectomy (n = 2). The results of pre-contrast MR tumor staging (T1, T2), viewing stages Tis-T2 collectively, and subsequent to separate assessments of stages T3b-T4b, were correct 76.6% of the time. Gadolinium-DTPA (Gd-DTPA) contrast-enhanced examinations (pre-contrast T1 and after Gd-DTPA) showed a staging accuracy rate of 85.7%. T2-weighted images did not indicate any advantage when compared to T1-weighted images following Gd-DTPA. The signal intensity ratios of tumor/fat and tumor/muscle tissue were measured on T1-weighted pre-contrast images and following Gd-DTPA and then evaluated statistically, whereby the increased tumor signal intensity was statistically significant (Wilcoxon test, P < 0.01). Due to the relatively short examination time needed for T1-weighted images and the specific tumor enhancement, the administration of Gd-DTPA proves valuable in the diagnosis of bladder carcinomas. T2-weighted images are not necessary. (orig.)

  6. Hyperspectral imaging system for disease scanning on banana plants

    Science.gov (United States)

    Ochoa, Daniel; Cevallos, Juan; Vargas, German; Criollo, Ronald; Romero, Dennis; Castro, Rodrigo; Bayona, Oswaldo

    2016-05-01

    Black Sigatoka (BS) is a banana plant disease caused by the fungus Mycosphaerella fijiensis. BS symptoms can be observed at late infection stages. By that time, BS has probably spread to other plants. In this paper, we present our current work on building an hyper-spectral (HS) imaging system aimed at in-vivo detection of BS pre-symptomatic responses in banana leaves. The proposed imaging system comprises a motorized stage, a high-sensitivity VIS-NIR camera and an optical spectrograph. To capture images of the banana leaf, the stage's speed and camera's frame rate must be computed to reduce motion blur and to obtain the same resolution along both spatial dimensions of the resulting HS cube. Our continuous leaf scanning approach allows imaging leaves of arbitrary length with minimum frame loss. Once the images are captured, a denoising step is performed to improve HS image quality and spectral profile extraction.

  7. Vision Servo Motion Control and Error Analysis of a Coplanar XXY Stage for Image Alignment Motion

    Directory of Open Access Journals (Sweden)

    Hau-Wei Lee

    2013-01-01

    Full Text Available In recent years, as there is demand for smart mobile phones with touch panels, the alignment/compensation system of alignment stage with vision servo control has also increased. Due to the fact that the traditional stacked-type XYθ stage has cumulative errors of assembly and it is heavy, it has been gradually replaced by the coplanar stage characterized by three actuators on the same plane with three degrees of freedom. The simplest image alignment mode uses two cameras as the equipments for feedback control, and the work piece is placed on the working stage. The work piece is usually engraved/marked. After the cameras capture images and when the position of the mark in the camera is obtained by image processing, the mark can be moved to the designated position in the camera by moving the stage and using alignment algorithm. This study used a coplanar XXY stage with 1 μm positioning resolution. Due to the fact that the resolution of the camera is about 3.75 μm per pixel, thus a subpixel technology is used, and the linear and angular alignment repeatability of the alignment system can achieve 1 μm and 5 arcsec, respectively. The visual servo motion control for alignment motion is completed within 1 second using the coplanar XXY stage.

  8. Histogram analysis of diffusion kurtosis imaging of nasopharyngeal carcinoma: Correlation between quantitative parameters and clinical stage.

    Science.gov (United States)

    Xu, Xiao-Quan; Ma, Gao; Wang, Yan-Jun; Hu, Hao; Su, Guo-Yi; Shi, Hai-Bin; Wu, Fei-Yun

    2017-07-18

    To evaluate the correlation between histogram parameters derived from diffusion-kurtosis (DK) imaging and the clinical stage of nasopharyngeal carcinoma (NPC). High T-stage (T3/4) NPC showed significantly higher Kapp-mean (P = 0.018), Kapp-median (P = 0.029) and Kapp-90th (P = 0.003) than low T-stage (T1/2) NPC. High N-stage NPC (N2/3) showed significantly lower Dapp-mean (P = 0.002), Dapp-median (P = 0.002) and Dapp-10th (P Histogram parameters, including mean, median, 10th, 90th percentiles, skewness and kurtosis of Dapp and Kapp were calculated. Patients were divided into low and high T, N and clinical stage based on American Joint Committee on Cancer (AJCC) staging system. Differences of histogram parameters between low and high T, N and AJCC stages were compared using t test. Multiple receiver operating characteristic (ROC) curves were used to determine and compare the value of significant parameters in predicting high T, N and AJCC stage, respectively. DK imaging-derived parameters correlated well with clinical stage of NPC, therefore could serve as an adjunctive imaging technique for evaluating NPC.

  9. Multipurpose Hyperspectral Imaging System

    Science.gov (United States)

    Mao, Chengye; Smith, David; Lanoue, Mark A.; Poole, Gavin H.; Heitschmidt, Jerry; Martinez, Luis; Windham, William A.; Lawrence, Kurt C.; Park, Bosoon

    2005-01-01

    A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

  10. Expandable image compression system: A modular approach

    International Nuclear Information System (INIS)

    Ho, B.K.T.; Lo, S.C.; Huang, H.K.

    1986-01-01

    The full-frame bit-allocation algorithm for radiological image compression can achieve an acceptable compression ratio as high as 30:1. It involves two stages of operation: a two-dimensional discrete cosine transform and pixel quantization in the transformed space with pixel depth kept accountable by a bit-allocation table. The cosine transform hardware design took an expandable modular approach based on the VME bus system with a maximum data transfer rate of 48 Mbytes/sec and a microprocessor (Motorola 68000 family). The modules are cascadable and microprogrammable to perform 1,024-point butterfly operations. A total of 18 stages would be required for transforming a 1,000 x 1,000 image. Multiplicative constants and addressing sequences are to be software loaded into the parameter buffers of each stage prior to streaming data through the processor stages. The compression rate for 1K x 1K images is expected to be faster than one image per sec

  11. Diagnosis and staging of breast cancer by SPECT images fused with CT images

    International Nuclear Information System (INIS)

    Li Yanjing; Zhu Qiaomei

    2007-01-01

    Objective: To evaluate the TNM staging value of 99mTc-MIBI scintimammotraphy with SPECT-CT images fusing for the diagnosis of breast cancer. Methods: 10 patients with breast cancer underwent scintimammography with 99mTc-MIBI, and SPECT images were fused with CT images. Images were compared with final diagnosis confirmed by histopathology. Results: Of the 19 breast cancer patients, one case of invasive ductal carcinoma showed false-negative. Among 18 cases of positive lesions, axillary metastases were involved in 10, supraclavicular nodes were also defined in 3, para-sternum nodes were involved in 2, 2 were missed and 1 cases without metastatic node. The axillary lymph nodes were divided into three levels with respect to their position relative to the pectoralis minor muscle by fused images. Conclusion: 99mTc-MIBI scintimammotraphy combined with SPECT-CT images fusing is of some clinical value in TNM staging of breast cancer. (authors)

  12. Spectral-domain optical coherence tomography staging and autofluorescence imaging in achromatopsia.

    Science.gov (United States)

    Greenberg, Jonathan P; Sherman, Jerome; Zweifel, Sandrine A; Chen, Royce W S; Duncker, Tobias; Kohl, Susanne; Baumann, Britta; Wissinger, Bernd; Yannuzzi, Lawrence A; Tsang, Stephen H

    2014-04-01

    IMPORTANCE Evidence is mounting that achromatopsia is a progressive retinal degeneration, and treatments for this condition are on the horizon. OBJECTIVES To categorize achromatopsia into clinically identifiable stages using spectral-domain optical coherence tomography and to describe fundus autofluorescence imaging in this condition. DESIGN, SETTING, AND PARTICIPANTS A prospective observational study was performed between 2010 and 2012 at the Edward S. Harkness Eye Institute, New York-Presbyterian Hospital. Participants included 17 patients (aged 10-62 years) with full-field electroretinography-confirmed achromatopsia. MAIN OUTCOMES AND MEASURES Spectral-domain optical coherence tomography features and staging system, fundus autofluorescence and near-infrared reflectance features and their correlation to optical coherence tomography, and genetic mutations served as the outcomes and measures. RESULTS Achromatopsia was categorized into 5 stages on spectral-domain optical coherence tomography: stage 1 (2 patients [12%]), intact outer retina; stage 2 (2 patients [12%]), inner segment ellipsoid line disruption; stage 3 (5 patients [29%]), presence of an optically empty space; stage 4 (5 patients [29%]), optically empty space with partial retinal pigment epithelium disruption; and stage 5 (3 patients [18%]), complete retinal pigment epithelium disruption and/or loss of the outer nuclear layer. Stage 1 patients showed isolated hyperreflectivity of the external limiting membrane in the fovea, and the external limiting membrane was hyperreflective above each optically empty space. On near infrared reflectance imaging, the fovea was normal, hyporeflective, or showed both hyporeflective and hyperreflective features. All patients demonstrated autofluorescence abnormalities in the fovea and/or parafovea: 9 participants (53%) had reduced or absent autofluorescence surrounded by increased autofluorescence, 4 individuals (24%) showed only reduced or absent autofluorescence, 3

  13. Images of gastric cancer stages

    International Nuclear Information System (INIS)

    Castro Aragon, I.M.

    1999-01-01

    The present work has the objective to review the importance of the images in the preoperating stage of the gastric cancer. It has been emphasized in the modalities of transabdominal ultrasound as much as endoscopic and TAC since they are most valuable in the stage. Certainly the importance of conventional radiology (gastroduodenal series) is also valuable in the stage of the tumor, specially in considering the depth of the same one. In order to make this overhaul, the recent bibliography was consulted but, specially the published one by Japaneses since they follow a classification and methodology different from the used one in most of the countries that belong to the World-wide Organization of the Health. They made an overhaul of approximately 200 cases of patients who have been diagnosed and treated in the Center of Detection of Gastric Cancer of Cartago. In each case review the file, radiological, sonographic and pathological studies, and the cases were chosen that better illustrated the exposed subjects. (Author) [es

  14. Operational Automatic Remote Sensing Image Understanding Systems: Beyond Geographic Object-Based and Object-Oriented Image Analysis (GEOBIA/GEOOIA. Part 2: Novel system Architecture, Information/Knowledge Representation, Algorithm Design and Implementation

    Directory of Open Access Journals (Sweden)

    Luigi Boschetti

    2012-09-01

    Full Text Available According to literature and despite their commercial success, state-of-the-art two-stage non-iterative geographic object-based image analysis (GEOBIA systems and three-stage iterative geographic object-oriented image analysis (GEOOIA systems, where GEOOIA/GEOBIA, remain affected by a lack of productivity, general consensus and research. To outperform the Quality Indexes of Operativeness (OQIs of existing GEOBIA/GEOOIA systems in compliance with the Quality Assurance Framework for Earth Observation (QA4EO guidelines, this methodological work is split into two parts. Based on an original multi-disciplinary Strengths, Weaknesses, Opportunities and Threats (SWOT analysis of the GEOBIA/GEOOIA approaches, the first part of this work promotes a shift of learning paradigm in the pre-attentive vision first stage of a remote sensing (RS image understanding system (RS-IUS, from sub-symbolic statistical model-based (inductive image segmentation to symbolic physical model-based (deductive image preliminary classification capable of accomplishing image sub-symbolic segmentation and image symbolic pre-classification simultaneously. In the present second part of this work, a novel hybrid (combined deductive and inductive RS-IUS architecture featuring a symbolic deductive pre-attentive vision first stage is proposed and discussed in terms of: (a computational theory (system design, (b information/knowledge representation, (c algorithm design and (d implementation. As proof-of-concept of symbolic physical model-based pre-attentive vision first stage, the spectral knowledge-based, operational, near real-time, multi-sensor, multi-resolution, application-independent Satellite Image Automatic Mapper™ (SIAM™ is selected from existing literature. To the best of these authors’ knowledge, this is the first time a symbolic syntactic inference system, like SIAM™, is made available to the RS community for operational use in a RS-IUS pre-attentive vision first stage

  15. Proposal for a new staging system for osteoradionecrosis of the mandible

    NARCIS (Netherlands)

    Karagozoglu, K.H.; Dekker, H.A.; Rietveld, D.; de Bree, R.; Schulten, E.A.J.M.; Kantola, S.; Forouzanfar, T.; van der Waal, I.

    2014-01-01

    A new staging system for osteoradionecrosis of the mandible has been retrospectively applied to a group of 31 patients. In this system clinicoradiographic signs and symptoms are incorporated in a simplified manner. For imaging purposes the use of plain radiographs such as periapical films and

  16. MRI imaging and staging of atlantodental lesions in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kuroda, Mana

    1992-01-01

    Sixty-five patients with a 3 year or more history of rheumatoid arthritis (RA) underwent magentic resonance (MR) imaging to determine the atlantodental interval (ADI), space available for the spinal cord (SAC), intensity of dens, dense erosion, periodontoid masses, and atlantodental subluxation. These MR findings were classified into stages 0 to IV. Stenbroker stage, disease duration, clinical symptoms, and ADI were compared with MR stages. Gd-DTPA enhanced MR images of the craniovertebral junction were also obtained in 16 patients with obvious periodontal pannus to examine a relationship between uptake of Gd-DTPA and quantitative C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and the joint score as the marker of the activity. Steinbroker stage, disease duration, and clinical symptoms were not correlaed with MR stage of craniovertebral junction. MR imaging was capable of detecting periodontoid lesion even in the early stage. It was also superior to conventional plain film and tomography in depicting the retrodental pannus without ADI dilatation. Pannus having noticeable contrast enhancement was associated with an extremely increased CRP and ESR. When it had no increase in signal intensity, laboratory findings were various. MR enhancement pattern seemed to correlate with RA activity. The present MR classification of atlantodental lesions would contribute to the therapeutic decision and evaluation of treatment outcome. (N.K.)

  17. MRI imaging and staging of atlantodental lesions in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Mana (Tokyo Medical Coll. (Japan))

    1992-03-01

    Sixty-five patients with a 3 year or more history of rheumatoid arthritis (RA) underwent magentic resonance (MR) imaging to determine the atlantodental interval (ADI), space available for the spinal cord (SAC), intensity of dens, dense erosion, periodontoid masses, and atlantodental subluxation. These MR findings were classified into stages 0 to IV. Stenbroker stage, disease duration, clinical symptoms, and ADI were compared with MR stages. Gd-DTPA enhanced MR images of the craniovertebral junction were also obtained in 16 patients with obvious periodontal pannus to examine a relationship between uptake of Gd-DTPA and quantitative C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and the joint score as the marker of the activity. Steinbroker stage, disease duration, and clinical symptoms were not correlaed with MR stage of craniovertebral junction. MR imaging was capable of detecting periodontoid lesion even in the early stage. It was also superior to conventional plain film and tomography in depicting the retrodental pannus without ADI dilatation. Pannus having noticeable contrast enhancement was associated with an extremely increased CRP and ESR. When it had no increase in signal intensity, laboratory findings were various. MR enhancement pattern seemed to correlate with RA activity. The present MR classification of atlantodental lesions would contribute to the therapeutic decision and evaluation of treatment outcome. (N.K.).

  18. [Retrospective analysis of 47 cases with hilar cholangiocarcinoma using T-staging system].

    Science.gov (United States)

    Peng, Cheng-hong; Zhao, Zhi-ming; Peng, Shu-you; Liu, Ying-bin; Wu, Yü-lian; Fang, He-qing; Jiang, Xian-chuan

    2005-01-01

    To evaluate the clinical value of T-staging system for hilar cholangiocarcinoma which was adopted in memorial Sloan-Kettering cancer center of New York. The image data of these 47 patients were analyzed retrospectively from December 1997 to December 2002 whose data were according with our demand, and they were staged into three-stage according to the criteria of the T-staging system. The difference of respectability, ratio of tumor-free resection margin and actuarial survival rate were analyzed for different T-staging. And the coincident ratio of three different kinds of imaging methods was also analyzed. Twenty patients had T(1) tumors, twenty three had T(2) tumors and four had T(3) tumors. The resectability of the three stage was 60%, 39% and 0% respectively, and the difference was significant (P = 0.013). The likelihood of achieving tumor-free margin decreased progressively with increasing T stage (P = 0.018). The cumulative 1-year survival rates of T(1), T(2) and T(3) patients were 60%, 39% and 0% respectively, and the cumulative 3-year survival rate was 35%, 9% and 0% respectively, the survival of different stage patients differed markedly (P = 0.0103). The coincident ratio of combined using MRCP and color Doppler-ultrasonography was higher than that of combined using MRCP and B-ultrasonography or combined using CT/SCT and color Doppler-ultrasonography (P = 0.007). The T-staging system has a better value for preoperative assessment, and can be used to judge resectability and survival of hilar cholangiocarcinoma. It will be helpful to use MRCP and color Doppler-Ultrasonography combined to verdict the coverage of the tumor and the T-staging preoperatively.

  19. Staging of nasopharyngeal carcinoma investigated by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lu Jincheng; Wei Baoqing; Chen Wenzhan; Qian Pudong; Zhang Yiqin; Wei Qing; Cha Wenwu; Li Feng; Ni Ming

    2006-01-01

    Background and purpose: To investigate the American Joint Commission on Cancer (AJCC) sixth edition staging system of nasopharyngeal carcinoma (NPC) by Magnetic Resonance Imaging (MRI). Patients and methods: One hundred and fifty-nine non-disseminated biopsy-proven NPC patients were studied with MRI before treatment. Retrieval of MRI information enabled us to restage all patients accurately according to the sixth edition of the AJCC staging system. Splitting the respective T and N stages by the significant defining factors identified, the cancer death hazard ratios were modeled by the Cox model in SPSS 10.0 for windows (SPSS Inc, Chicago, IL). Results: Single site of skull base abnormality (HR=3.91, 95% CI: 0.74-20.56) has a superior result to others involved in T3 (HR=5.83, 95% CI: 1.24-27.29). Involvement of either anterior or posterior cranial nerves solely (HR=6.02, 95% CI: 1.55-35.60) was not found to be as a poor prognostic indicator as others involved in T4 (HR=7.81, 95% CI: 1.81-33.63). Less than or equal to 3 cm of N1 (HR=4.01, 95% CI: 0.48-33.83) and N2 (HR=4.72, 95% CI: 0.62-35.78) have a better result than >3 cm of N1 (HR=8.09, 95% CI: 0.95-68.97) and N2 (HR=10.58, 95% CI: 1.32-84.62), respectively. Conclusions: Perhaps, it is better to down-stage single site of skull base abnormality from T3 to T2, and involvement of either anterior or posterior cranial nerves solely from T4 to T3, meanwhile, ≤3 cm of N2 down-stage to N1, >3 cm of N1 up-stage to N2

  20. The positive impact of radiologic imaging on high-stage cutaneous squamous cell carcinoma management.

    Science.gov (United States)

    Ruiz, Emily Stamell; Karia, Pritesh S; Morgan, Frederick C; Schmults, Chrysalyne D

    2017-02-01

    There is limited evidence on the utility of radiologic imaging for prognostic staging of cutaneous squamous cell carcinoma (CSCC). Review utilization of radiologic imaging of high-stage CSCCs to evaluate whether imaging impacted management and outcomes. Tumors classified as Brigham and Women's Hospital (BWH) tumor (T) stage T2B or T3 over a 13-year period were reviewed to identify whether imaging was performed and whether results affected treatment. Disease-related outcomes (DRO: local recurrence, nodal metastasis, death from disease) were compared between patients by type of imaging used. 108 high-stage CSCCs in 98 patients were included. Imaging (mostly computed tomography, 79%) was utilized in 45 (46%) patients and management was altered in 16 (33%) patients who underwent imaging. Patients that received no imaging were at higher risk of developing nodal metastases (nonimaging, 30%; imaging, 13%; P = .041) and any DRO (nonimaging, 42%; imaging, 20%; P = .028) compared to the imaging group. Imaging was associated with a lower risk for DRO (subhazard ratio, 0.5; 95% CI 0.2-0.9; P = .046) adjusted for BWH T stage, sex, and location. Single institution retrospective design and changes in technology overtime. Radiologic imaging of high-stage CSCC may influence management and appears to positively impact outcomes. Further prospective studies are needed to establish which patients benefit from imaging. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Operational Automatic Remote Sensing Image Understanding Systems: Beyond Geographic Object-Based and Object-Oriented Image Analysis (GEOBIA/GEOOIA. Part 1: Introduction

    Directory of Open Access Journals (Sweden)

    Andrea Baraldi

    2012-09-01

    Full Text Available According to existing literature and despite their commercial success, state-of-the-art two-stage non-iterative geographic object-based image analysis (GEOBIA systems and three-stage iterative geographic object-oriented image analysis (GEOOIA systems, where GEOOIA/GEOBIA, remain affected by a lack of productivity, general consensus and research. To outperform the degree of automation, accuracy, efficiency, robustness, scalability and timeliness of existing GEOBIA/GEOOIA systems in compliance with the Quality Assurance Framework for Earth Observation (QA4EO guidelines, this methodological work is split into two parts. The present first paper provides a multi-disciplinary Strengths, Weaknesses, Opportunities and Threats (SWOT analysis of the GEOBIA/GEOOIA approaches that augments similar analyses proposed in recent years. In line with constraints stemming from human vision, this SWOT analysis promotes a shift of learning paradigm in the pre-attentive vision first stage of a remote sensing (RS image understanding system (RS-IUS, from sub-symbolic statistical model-based (inductive image segmentation to symbolic physical model-based (deductive image preliminary classification. Hence, a symbolic deductive pre-attentive vision first stage accomplishes image sub-symbolic segmentation and image symbolic pre-classification simultaneously. In the second part of this work a novel hybrid (combined deductive and inductive RS-IUS architecture featuring a symbolic deductive pre-attentive vision first stage is proposed and discussed in terms of: (a computational theory (system design; (b information/knowledge representation; (c algorithm design; and (d implementation. As proof-of-concept of symbolic physical model-based pre-attentive vision first stage, the spectral knowledge-based, operational, near real-time Satellite Image Automatic Mapper™ (SIAM™ is selected from existing literature. To the best of these authors’ knowledge, this is the first time a

  2. Magnetic resonance imaging in the acute stage of cerebrovascular disease

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Sakai, Tsuneo; Fujishima, Ichiro; Yamamoto, Takamichi; Uemura, Kenichi; Teramura, Atsushi.

    1988-01-01

    Thirty patients with acute cerebrovascular disease were evaluated by both computed tomography (CT) and magnetic resonance (MR) imaging. The 17 patients with cerebral infarction (CI) were evaluated within 24 hours and the 13 with intracerebral hemorrhage (ICH) within 6 hours of the onset of symptoms. All ICHs were detected in T2-weighted images and appeared as perifocal, ring-like areas of high signal intensity. T2-weighted images also demonstrated a ruptured aneurysm and an arteriovenous malformation. In T1-weighted images, all ICHs displayed high signal intensity, which paralleled the CT images and is characteristic of MR imaging with an ultra-low magnetic filed. These findings were obtained as early as 90 minutes from the onset of symptoms. In cases of CI, T2-weighted images obtained 3 - 7 hours after onset demonstrated the pathology more clearly than did CT. This study proved MR imaging useful in the evaluation of both ICH and CI in the acute stage. In addition, it was possible to differentiate ICH from CI in the acute stage by T2-weighted images alone. (author)

  3. Two-stage image denoising considering interscale and intrascale dependencies

    Science.gov (United States)

    Shahdoosti, Hamid Reza

    2017-11-01

    A solution to the problem of reducing the noise of grayscale images is presented. To consider the intrascale and interscale dependencies, this study makes use of a model. It is shown that the dependency between a wavelet coefficient and its predecessors can be modeled by the first-order Markov chain, which means that the parent conveys all of the information necessary for efficient estimation. Using this fact, the proposed method employs the Kalman filter in the wavelet domain for image denoising. The proposed method has two stages. The first stage employs a simple denoising algorithm to provide the noise-free image, by which the parameters of the model such as state transition matrix, variance of the process noise, the observation model, and the covariance of the observation noise are estimated. In the second stage, the Kalman filter is applied to the wavelet coefficients of the noisy image to estimate the noise-free coefficients. In fact, the Kalman filter is used to estimate the coefficients of high-frequency subbands from the coefficients of coarser scales and noisy observations of neighboring coefficients. In this way, both the interscale and intrascale dependencies are taken into account. Results are presented and discussed on a set of standard 8-bit grayscale images. The experimental results demonstrate that the proposed method achieves performances competitive with the state-of-the-art denoising methods in terms of both peak-signal-to-noise ratio and subjective visual quality.

  4. An automated image processing method for classification of diabetic retinopathy stages from conjunctival microvasculature images

    Science.gov (United States)

    Khansari, Maziyar M.; O'Neill, William; Penn, Richard; Blair, Norman P.; Chau, Felix; Shahidi, Mahnaz

    2017-03-01

    The conjunctiva is a densely vascularized tissue of the eye that provides an opportunity for imaging of human microcirculation. In the current study, automated fine structure analysis of conjunctival microvasculature images was performed to discriminate stages of diabetic retinopathy (DR). The study population consisted of one group of nondiabetic control subjects (NC) and 3 groups of diabetic subjects, with no clinical DR (NDR), non-proliferative DR (NPDR), or proliferative DR (PDR). Ordinary least square regression and Fisher linear discriminant analyses were performed to automatically discriminate images between group pairs of subjects. Human observers who were masked to the grouping of subjects performed image discrimination between group pairs. Over 80% and 70% of images of subjects with clinical and non-clinical DR were correctly discriminated by the automated method, respectively. The discrimination rates of the automated method were higher than human observers. The fine structure analysis of conjunctival microvasculature images provided discrimination of DR stages and can be potentially useful for DR screening and monitoring.

  5. Multimodal imaging evaluation in staging of rectal cancer

    Science.gov (United States)

    Heo, Suk Hee; Kim, Jin Woong; Shin, Sang Soo; Jeong, Yong Yeon; Kang, Heoung-Keun

    2014-01-01

    Rectal cancer is a common cancer and a major cause of mortality in Western countries. Accurate staging is essential for determining the optimal treatment strategies and planning appropriate surgical procedures to control rectal cancer. Endorectal ultrasonography (EUS) is suitable for assessing the extent of tumor invasion, particularly in early-stage or superficial rectal cancer cases. In advanced cases with distant metastases, computed tomography (CT) is the primary approach used to evaluate the disease. Magnetic resonance imaging (MRI) is often used to assess preoperative staging and the circumferential resection margin involvement, which assists in evaluating a patient’s risk of recurrence and their optimal therapeutic strategy. Positron emission tomography (PET)-CT may be useful in detecting occult synchronous tumors or metastases at the time of initial presentation. Restaging after neoadjuvant chemoradiotherapy (CRT) remains a challenge with all modalities because it is difficult to reliably differentiate between the tumor mass and other radiation-induced changes in the images. EUS does not appear to have a useful role in post-therapeutic response assessments. Although CT is most commonly used to evaluate treatment responses, its utility for identifying and following-up metastatic lesions is limited. Preoperative high-resolution MRI in combination with diffusion-weighted imaging, and/or PET-CT could provide valuable prognostic information for rectal cancer patients with locally advanced disease receiving preoperative CRT. Based on these results, we conclude that a combination of multimodal imaging methods should be used to precisely assess the restaging of rectal cancer following CRT. PMID:24764662

  6. Hepatic imaging in stage IV-S neuroblastoma

    International Nuclear Information System (INIS)

    Franken, E.A. Jr.; Smith, W.L.; Iowa Univ., Iowa City; Cohen, M.D.; Kisker, C.T.; Platz, C.E.

    1986-01-01

    Stage IV-S neuroblastoma describes a group of infants with tumor spread limited to liver, skin, or bone marrow. Such patients, who constitute about 25% of affected infants with neuroblastoma, may expect spontaneous tumor remission. We report 18 infants with Stage IV-S neuroblastoma, 83% of whom had liver involvement. Imaging investigations included Technetium 99m sulfur colloid scan, ultrasound, and CT. Two patterns of liver metastasis were noted: ill-defined nodules or diffuse tumor throughout the liver. Distinction of normal and abnormal liver with diffuse type metastasis could be quite difficult, particularly with liver scans. We conclude that patients with Stage IV-S neuroblastoma have ultrasound or CT examination as an initial workup, with nuclear medicine scans reserved for followup studies. (orig.)

  7. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  8. Noncausal two-stage image filtration at presence of observations with anomalous errors

    OpenAIRE

    S. V. Vishnevyy; S. Ya. Zhuk; A. N. Pavliuchenkova

    2013-01-01

    Introduction. It is necessary to develop adaptive algorithms, which allow to detect such regions and to apply filter with respective parameters for suppression of anomalous noises for the purposes of image filtration, which consist of regions with anomalous errors. Development of adaptive algorithm for non-causal two-stage images filtration at pres-ence of observations with anomalous errors. The adaptive algorithm for noncausal two-stage filtration is developed. On the first stage the adaptiv...

  9. The usefulness of multiplanar reconstruction images in preoperative t-staging of advanced gastric cancer

    International Nuclear Information System (INIS)

    Koo, Young Baek; Kim, Suk; Lee, Jun Woo; Kim, Soo Jin; Choo, Ki Seok; Lee, Tae Hong; Moon, Tae Yong; Lee, Suk Hong; Jeon, Tae Yong

    2004-01-01

    The purpose of this study was to evaluate the performance of multidetector-row CT (MDCT) in the preoperative T-staging of patients with advanced gastric cancer. A total of 65 patients with an established diagnosis of advanced gastric cancer (T2 or more) were evaluated with MDCT. The protocol of MDCT consisted of high-quality (HQ) mode helical scanning with a slice thickness of 2.5 mm. The axial CT images were reconstructed with a slice thickness of 5 mm. MPR images were reconstructed from the raw axial data with a slice thickness of 5 mm. A comparison between the standard axial and axial MPR images was performed by two radiologists with regard to the evaluation of the tumor location and T-stage. These findings were compared with the pathologic and surgical findings. T-staging of the advanced stomach cancer was correct in 89% (58/65) and 69% (45/65) of the MPR images and axial images, respectively. The MPR images improved the detection rate (5 lesions) of the tumors and increased the accuracy of the T-staging (13 lesions) in comparison with the axial images. The MPR images are of greater diagnostic value for the evaluation of omental seeding (5 lesions: axial images, 9 lesions: MPR images), tumor location and extension. Multiplanar reconstruction (MPR) images provide increased confidence in the location and T-staging of certain cases of advanced gastric cancer, such as those in locations where CT images are susceptible to be affected by the difficulties associated with partial volume averaging. In this study, the MPR images provided more precise information about the tumor location and T-staging than the standard axial images in the preoperative evaluation of advanced gastric cancer

  10. Carcinoma of the cervix: Staging with MR imaging

    International Nuclear Information System (INIS)

    Waggenspack, G.A.; Amparo, E.G.; Fagan, C.J.; Hannigan, E.V.

    1986-01-01

    Forty MR imaging examinations in 38 patients with newly diagnosed or recurrent squamous cell carcinoma of the cervix were retrospectively evaluated and compared with clinical and surgical findings for staging. There was poor correlation between loss of fat planes and extension of tumor into the rectum or bladder, and it was impossible to differentiate bladder edema from direct invasion. MR imaging underestimated parametrial and pelvic sidewall extension when compared with physical exam under anesthesia. MR imaging was useful in the direct demonstration of a cervical mass and in detecting enlarged pelvic nodes

  11. A stage is a stage is a stage: a direct comparison of two scoring systems.

    Science.gov (United States)

    Dawson, Theo L

    2003-09-01

    L. Kohlberg (1969) argued that his moral stages captured a developmental sequence specific to the moral domain. To explore that contention, the author compared stage assignments obtained with the Standard Issue Scoring System (A. Colby & L. Kohlberg, 1987a, 1987b) and those obtained with a generalized content-independent stage-scoring system called the Hierarchical Complexity Scoring System (T. L. Dawson, 2002a), on 637 moral judgment interviews (participants' ages ranged from 5 to 86 years). The correlation between stage scores produced with the 2 systems was .88. Although standard issue scoring and hierarchical complexity scoring often awarded different scores up to Kohlberg's Moral Stage 2/3, from his Moral Stage 3 onward, scores awarded with the two systems predominantly agreed. The author explores the implications for developmental research.

  12. Forensic age estimation based on magnetic resonance imaging of third molars: converting 2D staging into 3D staging.

    Science.gov (United States)

    De Tobel, Jannick; Hillewig, Elke; Verstraete, Koenraad

    2017-03-01

    Established methods to stage development of third molars for forensic age estimation are based on the evaluation of radiographs, which show a 2D projection. It has not been investigated whether these methods require any adjustments in order to apply them to stage third molars on magnetic resonance imaging (MRI), which shows 3D information. To prospectively study root stage assessment of third molars in age estimation using 3 Tesla MRI and to compare this with panoramic radiographs, in order to provide considerations for converting 2D staging into 3D staging and to determine the decisive root. All third molars were evaluated in 52 healthy participants aged 14-26 years using MRI in three planes. Three staging methods were investigated by two observers. In sixteen of the participants, MRI findings were compared with findings on panoramic radiographs. Decisive roots were palatal in upper third molars and distal in lower third molars. Fifty-seven per cent of upper third molars were not assessable on the radiograph, while 96.9% were on MRI. Upper third molars were more difficult to evaluate on radiographs than on MRI (p third molars were equally assessable on both imaging techniques (93.8% MRI, 98.4% radiograph), with no difference in level of difficulty (p = .375). Inter- and intra-observer agreement for evaluation was higher in MRI than in radiographs. In both imaging techniques lower third molars showed greater inter- and intra-observer agreement compared to upper third molars. MR images in the sagittal plane proved to be essential for staging. In age estimation, 3T MRI of third molars could be valuable. Some considerations are, however, necessary to transfer known staging methods to this 3D technique.

  13. Optimization of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Alberto Izquierdo Fuente

    2014-01-01

    Full Text Available On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced.

  14. Optimization of a Biometric System Based on Acoustic Images

    Science.gov (United States)

    Izquierdo Fuente, Alberto; Del Val Puente, Lara; Villacorta Calvo, Juan J.; Raboso Mateos, Mariano

    2014-01-01

    On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced. PMID:24616643

  15. Breast imaging with the SoftVue imaging system: first results

    Science.gov (United States)

    Duric, Neb; Littrup, Peter; Schmidt, Steven; Li, Cuiping; Roy, Olivier; Bey-Knight, Lisa; Janer, Roman; Kunz, Dave; Chen, Xiaoyang; Goll, Jeffrey; Wallen, Andrea; Zafar, Fouzaan; Allada, Veerendra; West, Erik; Jovanovic, Ivana; Li, Kuo; Greenway, William

    2013-03-01

    For women with dense breast tissue, who are at much higher risk for developing breast cancer, the performance of mammography is at its worst. Consequently, many early cancers go undetected when they are the most treatable. Improved cancer detection for women with dense breasts would decrease the proportion of breast cancers diagnosed at later stages, which would significantly lower the mortality rate. The emergence of whole breast ultrasound provides good performance for women with dense breast tissue, and may eliminate the current trade-off between the cost effectiveness of mammography and the imaging performance of more expensive systems such as magnetic resonance imaging. We report on the performance of SoftVue, a whole breast ultrasound imaging system, based on the principles of ultrasound tomography. SoftVue was developed by Delphinus Medical Technologies and builds on an early prototype developed at the Karmanos Cancer Institute. We present results from preliminary testing of the SoftVue system, performed both in the lab and in the clinic. These tests aimed to validate the expected improvements in image performance. Initial qualitative analyses showed major improvements in image quality, thereby validating the new imaging system design. Specifically, SoftVue's imaging performance was consistent across all breast density categories and had much better resolution and contrast. The implications of these results for clinical breast imaging are discussed and future work is described.

  16. All-optical photoacoustic imaging and detection of early-stage dental caries

    Science.gov (United States)

    Sampathkumar, Ashwin; Hughes, David A.; Longbottom, Chris; Kirk, Katherine J.

    2015-02-01

    Dental caries remain one of the most common oral diseases in the world. Current detection methods, such as dental explorer and X-ray radiography, suffer from poor sensitivity and specificity at the earliest (and reversible) stages of the disease because of the small size (tooth decay. This AOPAI system provides a non-contact, non-invasive and non-ionizing means of detecting early-stage dental caries. Ex-vivo teeth exhibiting early-stage, white-spot lesions were imaged using AOPAI. Experimental scans targeted each early-stage lesion and a reference healthy enamel region. Photoacoustic (PA) signals were generated in the tooth using a 532-nm pulsed laser and the light-induced broadband ultrasound signal was detected at the surface of the tooth with an optical path-stabilized Michelson interferometer operating at 532 nm. The measured time-domain signal was spatially resolved and back-projected to form 2D and 3D maps of the lesion using k-wave reconstruction methods. Experimental data collected from areas of healthy and diseased enamel indicate that the lesion generated a larger PA response compared to healthy enamel. The PA-signal amplitude alone was able to detect a lesion on the surface of the tooth. However, time- reversal reconstructions of the PA scans also quantitatively depicted the depth of the lesion. 3D PA reconstruction of the diseased tooth indicated a sub-surface lesion at a depth of 0.6 mm, in addition to the surface lesion. These results suggest that our AOPAI system is well suited for rapid clinical assessment of early-stage dental caries. An overview of the AOPAI system, fine-resolution PA and histology results of diseased and healthy teeth will be presented.

  17. Development and applications of a two-dimensional tip-tilting stage system with nanoradian-level positioning resolution

    Energy Technology Data Exchange (ETDEWEB)

    Shu Deming, E-mail: shu@aps.anl.gov [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Lee, Wah-Keat; Liu, Wenjun [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Ice, Gene E. [MST Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6132 (United States); Shvyd' ko, Yuri; Kim, Kwang-Je [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2011-09-01

    In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

  18. Advanced imaging of skeletal manifestations of systemic mastocytosis

    International Nuclear Information System (INIS)

    Fritz, J.; Fishman, E.K.; Carrino, J.A.; Horger, M.S.

    2012-01-01

    Systemic mastocytosis comprises a group of clonal disorders of the mast cell that most commonly involves the skeletal system. Imaging can be helpful in the detection and characterization of the osseous manifestations of this disease. While radiography and bone scans are frequently used for this assessment, low-dose multidetector computed tomography and magnetic resonance imaging can be more sensitive for the detection of marrow involvement and for the demonstration of the various disease patterns. In this article, we review the pathophysiological and clinical features of systemic mastocytosis, discuss the role of imaging for staging and management, and illustrate the various cross-sectional imaging appearances. Awareness and knowledge of the imaging features of this disorder will increase the accuracy of image interpretation and can contribute important information for management decisions. (orig.)

  19. Advanced imaging of skeletal manifestations of systemic mastocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Fishman, E.K.; Carrino, J.A. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Horger, M.S. [Eberhard-Karls-University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2012-08-15

    Systemic mastocytosis comprises a group of clonal disorders of the mast cell that most commonly involves the skeletal system. Imaging can be helpful in the detection and characterization of the osseous manifestations of this disease. While radiography and bone scans are frequently used for this assessment, low-dose multidetector computed tomography and magnetic resonance imaging can be more sensitive for the detection of marrow involvement and for the demonstration of the various disease patterns. In this article, we review the pathophysiological and clinical features of systemic mastocytosis, discuss the role of imaging for staging and management, and illustrate the various cross-sectional imaging appearances. Awareness and knowledge of the imaging features of this disorder will increase the accuracy of image interpretation and can contribute important information for management decisions. (orig.)

  20. The International Neuroblastoma Risk Group (INRG) staging system: an INRG Task Force report.

    Science.gov (United States)

    Monclair, Tom; Brodeur, Garrett M; Ambros, Peter F; Brisse, Hervé J; Cecchetto, Giovanni; Holmes, Keith; Kaneko, Michio; London, Wendy B; Matthay, Katherine K; Nuchtern, Jed G; von Schweinitz, Dietrich; Simon, Thorsten; Cohn, Susan L; Pearson, Andrew D J

    2009-01-10

    The International Neuroblastoma Risk Group (INRG) classification system was developed to establish a consensus approach for pretreatment risk stratification. Because the International Neuroblastoma Staging System (INSS) is a postsurgical staging system, a new clinical staging system was required for the INRG pretreatment risk classification system. To stage patients before any treatment, the INRG Task Force, consisting of neuroblastoma experts from Australia/New Zealand, China, Europe, Japan, and North America, developed a new INRG staging system (INRGSS) based on clinical criteria and image-defined risk factors (IDRFs). To investigate the impact of IDRFs on outcome, survival analyses were performed on 661 European patients with INSS stages 1, 2, or 3 disease for whom IDRFs were known. In the INGRSS, locoregional tumors are staged L1 or L2 based on the absence or presence of one or more of 20 IDRFs, respectively. Metastatic tumors are defined as stage M, except for stage MS, in which metastases are confined to the skin, liver, and/or bone marrow in children younger than 18 months of age. Within the 661-patient cohort, IDRFs were present (ie, stage L2) in 21% of patients with stage 1, 45% of patients with stage 2, and 94% of patients with stage 3 disease. Patients with INRGSS stage L2 disease had significantly lower 5-year event-free survival than those with INRGSS stage L1 disease (78% +/- 4% v 90% +/- 3%; P = .0010). Use of the new staging (INRGSS) and risk classification (INRG) of neuroblastoma will greatly facilitate the comparison of risk-based clinical trials conducted in different regions of the world.

  1. Use of posttreatment imaging and biomarkers in survivors of early-stage breast cancer: Inappropriate surveillance or necessary care?

    Science.gov (United States)

    Hahn, Erin E; Tang, Tania; Lee, Janet S; Munoz-Plaza, Corrine E; Shen, Ernest; Rowley, Braden; Maeda, Jared L; Mosen, David M; Ruckdeschel, John C; Gould, Michael K

    2016-03-15

    Advanced imaging and serum biomarkers are commonly used for surveillance in patients with early-stage breast cancer, despite recommendations against this practice. Incentives to perform such low-value testing may be less prominent in integrated health care delivery systems. The purpose of the current study was to evaluate and compare the use of these services within 2 integrated systems: Kaiser Permanente (KP) and Intermountain Healthcare (IH). The authors also sought to distinguish the indication for testing: diagnostic purposes or routine surveillance. Patients with American Joint Committee on Cancer stage 0 to II breast cancer diagnosed between 2009 and 2010 were identified and the use of imaging and biomarker tests over an 18-month period were quantified, starting at 1 year after diagnosis. Chart abstraction was performed on a random sample of patients who received testing to identify the indication for testing. Multivariate regression was used to explore associations with the use of nonrecommended care. A total of 6585 patients were identified; 22% had stage 0 disease, 44% had stage I disease, and 34% had stage II disease. Overall, 24% of patients received at least 1 imaging test (25% at KP vs 22% at IH; P = .009) and 28% of patients received at least 1 biomarker (36% at KP vs 13% at IH; Ptests were performed to evaluate symptoms or signs. Virtually all biomarkers were ordered for routine surveillance. Stage of disease, medical center that provided the services, and provider experience were found to be significantly associated with the use of biomarkers. Advanced imaging was most often performed for appropriate indications, but biomarkers were used for nonrecommended surveillance. Distinguishing between inappropriate use for surveillance and appropriate diagnostic testing is essential when evaluating adherence to recommendations. © 2015 American Cancer Society.

  2. Comparative study on developmental stages of the clavicle by postmortem MRI and CT imaging

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels; Jensen, K.E.

    2013-01-01

    Objectives: The developmental stages of the clavicles are important for forensic age estimation purposes in adolescents. This study compares the 4-stage system to evaluate the ossification of the medial end of the clavicle as visualized by magnetic resonance imaging (MRI) and computed tomography...... (CT). As several forensic institutes routinely perform CT scans, the large amount of available data may serve as reference sample for MRI in specific cases. Material and methods: This prospective study included an MRI and CT scan of 47 autopsy cases performed prior to medico-legal autopsy (age range...

  3. Area Determination of Diabetic Foot Ulcer Images Using a Cascaded Two-Stage SVM-Based Classification.

    Science.gov (United States)

    Wang, Lei; Pedersen, Peder C; Agu, Emmanuel; Strong, Diane M; Tulu, Bengisu

    2017-09-01

    The standard chronic wound assessment method based on visual examination is potentially inaccurate and also represents a significant clinical workload. Hence, computer-based systems providing quantitative wound assessment may be valuable for accurately monitoring wound healing status, with the wound area the best suited for automated analysis. Here, we present a novel approach, using support vector machines (SVM) to determine the wound boundaries on foot ulcer images captured with an image capture box, which provides controlled lighting and range. After superpixel segmentation, a cascaded two-stage classifier operates as follows: in the first stage, a set of k binary SVM classifiers are trained and applied to different subsets of the entire training images dataset, and incorrectly classified instances are collected. In the second stage, another binary SVM classifier is trained on the incorrectly classified set. We extracted various color and texture descriptors from superpixels that are used as input for each stage in the classifier training. Specifically, color and bag-of-word representations of local dense scale invariant feature transformation features are descriptors for ruling out irrelevant regions, and color and wavelet-based features are descriptors for distinguishing healthy tissue from wound regions. Finally, the detected wound boundary is refined by applying the conditional random field method. We have implemented the wound classification on a Nexus 5 smartphone platform, except for training which was done offline. Results are compared with other classifiers and show that our approach provides high global performance rates (average sensitivity = 73.3%, specificity = 94.6%) and is sufficiently efficient for a smartphone-based image analysis.

  4. Use of infrared imaging to predict the developmental stages and differences in chicken embryos exposed to different photoperiods

    Science.gov (United States)

    Frederick, Rebecca A.; Hsieh, Sheng-Jen; Palomares, Benjamin Giron

    2012-06-01

    Monitoring development of chicken embryos allows determination of when an egg is not developing and when eggs are close to hatching for more efficient production. Research has been conducted on the effects of temperature fluctuations and light exposure on embryo development; similarities between chicken and mammal embryos; and the use of MRI, tomography, and ultrasound to view specific areas and processes within the embryo. However, there has been little exploration of the use of infrared imaging as a non-destructive method for analyzing and predicting embryonic development. In this study, we built an automated loading system for image acquisition. Pilot experiments were conducted to determine the overall scanning time and scanning frequency. A batch of fertilized eggs was scanned each day as the embryos continued to grow. The captured images were analyzed and categorized into three stages: Stage 1 (days 1 to 7), Stage 2 (days 8 to 14), and Stage 3 (days 15 to 21). The temperature data abstracted from the captured images were divided into two groups. Group 1, consisting of two-thirds of the data, was used to construct a model. Group 2, consisting of one-third of the data, was used to evaluate the predictive accuracy of the model. A three-layer artificial neural network model was developed to predict embryo development stage given a temperature profile. Results suggest that the neural network model is sufficient to predict embryo development stage with good accuracy of 75%. Accuracy can likely be improved if more data sets for each development stage are available.

  5. Synthetic aperture flow imaging using dual stage beamforming

    DEFF Research Database (Denmark)

    Li, Ye; Jensen, Jørgen Arendt

    2013-01-01

    A method for synthetic aperture flow imaging using dual stage beamforming has been developed. The main motivation is to increase the frame rate and still maintain a beamforming quality sufficient for flow estimation that is possible to implement in a commercial scanner. This method can generate...

  6. Classification of Diabetic Macular Edema and Its Stages Using Color Fundus Image

    Institute of Scientific and Technical Information of China (English)

    Muhammad Zubair; Shoab A. Khan; Ubaid Ullah Yasin

    2014-01-01

    Diabetic macular edema (DME) is a retinal thickening involving the center of the macula. It is one of the serious eye diseases which affects the central vision and can lead to partial or even complete visual loss. The only cure is timely diagnosis, prevention, and treatment of the disease. This paper presents an automated system for the diagnosis and classification of DME using color fundus image. In the proposed technique, first the optic disc is removed by applying some preprocessing steps. The preprocessed image is then passed through a classifier for segmentation of the image to detect exudates. The classifier uses dynamic thresholding technique by using some input parameters of the image. The stage classification is done on the basis of anearly treatment diabetic retinopathy study (ETDRS) given criteria to assess the severity of disease. The proposed technique gives a sensitivity, specificity, and accuracy of 98.27%, 96.58%, and 96.54%, respectively on publically available database.

  7. OLGA- and OLGIM-based staging of gastritis using narrow-band imaging magnifying endoscopy.

    Science.gov (United States)

    Saka, Akiko; Yagi, Kazuyoshi; Nimura, Satoshi

    2015-11-01

    As atrophic gastritis and intestinal metaplasia as a result of Helicobacter pylori are considered risk factors for gastric cancer, it is important to assess their severity. In the West, the operative link for gastritis assessment (OLGA) and operative link for gastric intestinal metaplasia assessment (OLGIM) staging systems based on biopsy have been widely adopted. In Japan, however, narrow-band imaging (NBI)-magnifying endoscopic diagnosis of gastric mucosal inflammation, atrophy, and intestinal metaplasia has been reported to be fairly accurate. Therefore, we investigated the practicality of NBI-magnifying endoscopy (NBI-ME) for gastritis staging. We enrolled 55 patients, in whom NBI-ME was used to score the lesser curvature of the antrum (antrum) and the lesser curvature of the lower body (corpus). The NBI-ME score classification was established from images obtained beforehand, and then biopsy specimens taken from the observed areas were scored according to histological findings. The NBI-ME and histology scores were then compared. Furthermore, we assessed the NBI-ME and histology stages using a combination of scores for the antrum and corpus, and divided the stages into two risk groups: low and high. The degree to which the stage assessed by NBI-ME approximated that assessed by histology was then ascertained. Degree of correspondence between the NBI-ME and histology scores was 69.1% for the antrum and 72.7% for the corpus, and that between the high- and low-risk groups was 89.1%. Staging of gastritis using NBI-ME approximates that based on histology, and would be a practical alternative to the latter. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  8. Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.O.; Orton, M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Morgan, B. [Univ. of Leicester, College of Medicine, Biological Sciences and Psychology, Leicester (United Kingdom); Tofts, P.S. [Brighton and Sussex Medical School, Univ. of Sussex, Clinical Imaging Sciences Centre, Sussex (United Kingdom); Buckley, D.L. [University of Leeds, Division of Medical Physics, Leeds (United Kingdom); Huang, W. [Oregon Health and Science Univ., Advanced Imaging Research Centre, Portland, OR (United States); Horsfield, M.A. [Medical Physics Section, Leicester Royal Infirmary, Dept. of Cardiovascular Sciences, Leicester (United Kingdom); Chenevert, T.L. [Univ. of Michigan Health System, Ann Arbor, MI (United States); Collins, D.J. [Royal Marsden Hospital NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Jackson, A. [Univ. of Manchester, Wolfson Molecular Imaging Centre, Withington, Manchester, M20 3LJ (United Kingdom); Lomas, D. [Univ. of Cambridge, Dept. of Radiology, Cambridge (United Kingdom); Whitcher, B. [Unit 2 Greenways Business Park, Mango Solutions, Chippenham (United Kingdom); Clarke, L. [Cancer Imaging Program, Imaging Technology Development Branch, Rockville, MD (United States); Plummer, R. [Univ. of Newcastle Upon Tyne, The Medical School, Medical Oncology, Northern Inst. for Cancer Research, Newcastle Upon Tyne (United Kingdom); Judson, I. [Royal Marsden Hospital, Sutton, Surrey (United Kingdom); Jones, R. [Beatson West of Scotland Cancer Centre, Glasgow (United Kingdom); Alonzi, R. [Mount Vernon Cancer Centre, Northwood (United Kingdom); Brunner, T. [Gray Inst. for Radiation, Oncology and Biology, Oxford (United Kingdom); Koh, D.M. [Royal Marsden NHS Foundation Trust, Diagnostic Radiology, Sutton, Surrey (United Kingdom)] [and others

    2012-07-15

    Many therapeutic approaches to cancer affect the tumour vasculature, either indirectly or as a direct target. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important means of investigating this action, both pre-clinically and in early stage clinical trials. For such trials, it is essential that the measurement process (i.e. image acquisition and analysis) can be performed effectively and with consistency among contributing centres. As the technique continues to develop in order to provide potential improvements in sensitivity and physiological relevance, there is considerable scope for between-centre variation in techniques. A workshop was convened by the Imaging Committee of the Experimental Cancer Medicine Centres (ECMC) to review the current status of DCE-MRI and to provide recommendations on how the technique can best be used for early stage trials. This review and the consequent recommendations are summarised here. (orig.)

  9. Bladder cancer staging in CT urography: effect of stage labels on statistical modeling of a decision support system

    Science.gov (United States)

    Gandikota, Dhanuj; Hadjiiski, Lubomir; Cha, Kenny H.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon; Alva, Ajjai; Paramagul, Chintana; Wei, Jun; Zhou, Chuan

    2018-02-01

    In bladder cancer, stage T2 is an important threshold in the decision of administering neoadjuvant chemotherapy. Our long-term goal is to develop a quantitative computerized decision support system (CDSS-S) to aid clinicians in accurate staging. In this study, we examined the effect of stage labels of the training samples on modeling such a system. We used a data set of 84 bladder cancers imaged with CT Urography (CTU). At clinical staging prior to treatment, 43 lesions were staged as below stage T2 and 41 were stage T2 or above. After cystectomy and pathological staging that is considered the gold standard, 10 of the lesions were upstaged to stage T2 or above. After correcting the stage labels, 33 lesions were below stage T2, and 51 were stage T2 or above. For the CDSS-S, the lesions were segmented using our AI-CALS method and radiomic features were extracted. We trained a linear discriminant analysis (LDA) classifier with leave-one-case-out cross validation to distinguish between bladder lesions of stage T2 or above and those below stage T2. The CDSS-S was trained and tested with the corrected post-cystectomy labels, and as a comparison, CDSS-S was also trained with understaged pre-treatment labels and tested on lesions with corrected labels. The test AUC for the CDSS-S trained with corrected labels was 0.89 +/- 0.04. For the CDSS-S trained with understaged pre-treatment labels and tested on the lesions with corrected labels, the test AUC was 0.86 +/- 0.04. The likelihood of stage T2 or above for 9 out of the 10 understaged lesions was correctly increased for the CDSS-S trained with corrected labels. The CDSS-S is sensitive to the accuracy of stage labeling. The CDSS-S trained with correct labels shows promise in prediction of the bladder cancer stage.

  10. The correlation of preoperative CT, MR imaging, and clinical staging (FIGO) with histopathology findings in primary cervical carcinoma

    International Nuclear Information System (INIS)

    Oezsarlak, Oe.; Schepens, E.; Corthouts, B.; Beeck, B.O. de; Parizel, P.M.; De Schepper, A.M.; Tjalma, W.; Marck, E. van

    2003-01-01

    The aim of this study was to compare the preoperative findings of abdominal/pelvic CT and MRI with the preoperative clinical International Federation of Obstetrics and Gynecology (FIGO) staging and postoperative pathology report in patients with primary cancer of the cervix. Thirty-six patients with surgical-pathological proven primary cancer of the cervix were retrospectively studied for preoperative staging by clinical examination, CT, and MR imaging. Studied parameters for preoperative staging were the presence of tumor, tumor extension into the parametrial tissue, pelvic wall, adjacent organs, and lymph nodes. The CT was performed in 32 patients and MRI (T1- and T2-weighted images) in 29 patients. The CT and MR staging were based on the FIGO staging system. Results were compared with histological findings. The group is consisted of stage 0 (in situ):1, Ia:1, Ib:8, IIa:2, IIb:12, IIIa:4, IVa:6, and IVb:2 patients. The overall accuracy of staging for clinical examination, CT, and MRI was 47, 53, and 86%, respectively. The MRI incorrectly staged 2 patients and did not visualize only two tumors; one was an in situ (stage-0) and one stage-Ia (microscopic) disease. The MRI is more accurate than CT and they are both superior to clinical examination in evaluating the locoregional extension and preoperative staging of primary cancer of the cervix. (orig.)

  11. Operation of staged membrane oxidation reactor systems

    Science.gov (United States)

    Repasky, John Michael

    2012-10-16

    A method of operating a multi-stage ion transport membrane oxidation system. The method comprises providing a multi-stage ion transport membrane oxidation system with at least a first membrane oxidation stage and a second membrane oxidation stage, operating the ion transport membrane oxidation system at operating conditions including a characteristic temperature of the first membrane oxidation stage and a characteristic temperature of the second membrane oxidation stage; and controlling the production capacity and/or the product quality by changing the characteristic temperature of the first membrane oxidation stage and/or changing the characteristic temperature of the second membrane oxidation stage.

  12. An adaptive optics imaging system designed for clinical use

    Science.gov (United States)

    Zhang, Jie; Yang, Qiang; Saito, Kenichi; Nozato, Koji; Williams, David R.; Rossi, Ethan A.

    2015-01-01

    Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2–3 arc minutes, (arcmin) 2) ~0.5–0.8 arcmin and, 3) ~0.05–0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3–5 arcmin, 2) ~0.7–1.1 arcmin and 3) ~0.07–0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing. PMID:26114033

  13. Development of a nomogram combining clinical staging with 18F-FDG PET/CT image features in non-small-cell lung cancer stage I-III

    International Nuclear Information System (INIS)

    Desseroit, Marie-Charlotte; Visvikis, Dimitris; Majdoub, Mohamed; Hatt, Mathieu; Tixier, Florent; Perdrisot, Remy; Cheze Le Rest, Catherine; Guillevin, Remy

    2016-01-01

    Our goal was to develop a nomogram by exploiting intratumour heterogeneity on CT and PET images from routine 18 F-FDG PET/CT acquisitions to identify patients with the poorest prognosis. This retrospective study included 116 patients with NSCLC stage I, II or III and with staging 18 F-FDG PET/CT imaging. Primary tumour volumes were delineated using the FLAB algorithm and 3D Slicer trademark on PET and CT images, respectively. PET and CT heterogeneities were quantified using texture analysis. The reproducibility of the CT features was assessed on a separate test-retest dataset. The stratification power of the PET/CT features was evaluated using the Kaplan-Meier method and the log-rank test. The best standard metric (functional volume) was combined with the least redundant and most prognostic PET/CT heterogeneity features to build the nomogram. PET entropy and CT zone percentage had the highest complementary values with clinical stage and functional volume. The nomogram improved stratification amongst patients with stage II and III disease, allowing identification of patients with the poorest prognosis (clinical stage III, large tumour volume, high PET heterogeneity and low CT heterogeneity). Intratumour heterogeneity quantified using textural features on both CT and PET images from routine staging 18 F-FDG PET/CT acquisitions can be used to create a nomogram with higher stratification power than staging alone. (orig.)

  14. Improvement of the image quality of a high-temperature vision system

    International Nuclear Information System (INIS)

    Fabijańska, Anna; Sankowski, Dominik

    2009-01-01

    In this paper, the issues of controlling and improving the image quality of a high-temperature vision system are considered. The image quality improvement is needed to measure the surface properties of metals and alloys. Two levels of image quality control and improvement are defined in the system. The first level in hardware aims at adjusting the system configuration to obtain the highest contrast and weakest aura images. When optimal configuration is obtained, the second level in software is applied. In this stage, image enhancement algorithms are applied which have been developed with consideration of distortions arising from the vision system components and specificity of images acquired during the measurement process. The developed algorithms have been applied in the vision system to images. The influence on the accuracy of wetting angles and surface tension determination are considered

  15. Nondestructive Imaging of an Object Using the Compact Continuous-Wave Sub-Terahertz Imaging System

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Seok; Kwon, Il Bub; Yoon, Dong Jin; Seo, Dae Cheol [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2010-08-15

    This paper presented compact CW sub-THz imaging system using the terahertz transmitter(Tx) that generating 0.34 THz electromagnetic wave on based electronic device. Using 0.34 THz electromagnetic wave generated by Tx, we transmitted to sample by point by point scan method and measured transmitting terahertz wave magnitude and phase information respectively with terahertz receiver(Rx) based on sub harmonic mixer. This paper measured and compared images of several samples to obtain better imaging results by changing time delay and step distance of scanning stage which affect image resolution. Also, through the imaging measurement of various samples, we were able to assure possibility of application of terahertz wave

  16. Nondestructive Imaging of an Object Using the Compact Continuous-Wave Sub-Terahertz Imaging System

    International Nuclear Information System (INIS)

    Jang, Jin Seok; Kwon, Il Bub; Yoon, Dong Jin; Seo, Dae Cheol

    2010-01-01

    This paper presented compact CW sub-THz imaging system using the terahertz transmitter(Tx) that generating 0.34 THz electromagnetic wave on based electronic device. Using 0.34 THz electromagnetic wave generated by Tx, we transmitted to sample by point by point scan method and measured transmitting terahertz wave magnitude and phase information respectively with terahertz receiver(Rx) based on sub harmonic mixer. This paper measured and compared images of several samples to obtain better imaging results by changing time delay and step distance of scanning stage which affect image resolution. Also, through the imaging measurement of various samples, we were able to assure possibility of application of terahertz wave

  17. COOLING STAGES OF CRYOGENIC SYSTEMS

    OpenAIRE

    Троценко, А. В.

    2011-01-01

    The formalized definition for cooling stage of low temperature system is done. Based on existing information about the known cryogenic unit cycles the possible types of cooling stages are single out. From analyses of these stages their classification by various characteristics is suggested. The results of thermodynamic optimization of final throttle stage of cooling, which are used as working fluids helium, hydrogen and nitrogen, are shown.

  18. Detection and preoperative staging of carcinoma of the cervix: Comparison between MR imaging and CT

    International Nuclear Information System (INIS)

    Mayr, B.; Schmidt, H.; Baieri, P.; Scheidel, P.; Meier, W.; Schramm, T.

    1986-01-01

    Twenty-four patients with carcinoma of the cervix were examined preoperatively by MR imaging and CT. In all patients histopathologic confirmation was available for specimens obtained either by radical hysterectomy or at staging laparotomy. MR imaging was equivalent to contrast CT in the detection and evaluation of tumor extension in the cervix. Tumor extension to the parametria and pelvic wall was difficult to evaluate on both modalities, as neither had a higher accuracy than pelvic examination conducted under anesthesia. Nodal staging was nearly equivalent on MR imaging and CT. In the detection and staging of carcinoma of the cervix, MR imaged proved to be as good as CT with contrast agent enhancement

  19. High-speed cell recognition algorithm for ultrafast flow cytometer imaging system

    Science.gov (United States)

    Zhao, Wanyue; Wang, Chao; Chen, Hongwei; Chen, Minghua; Yang, Sigang

    2018-04-01

    An optical time-stretch flow imaging system enables high-throughput examination of cells/particles with unprecedented high speed and resolution. A significant amount of raw image data is produced. A high-speed cell recognition algorithm is, therefore, highly demanded to analyze large amounts of data efficiently. A high-speed cell recognition algorithm consisting of two-stage cascaded detection and Gaussian mixture model (GMM) classification is proposed. The first stage of detection extracts cell regions. The second stage integrates distance transform and the watershed algorithm to separate clustered cells. Finally, the cells detected are classified by GMM. We compared the performance of our algorithm with support vector machine. Results show that our algorithm increases the running speed by over 150% without sacrificing the recognition accuracy. This algorithm provides a promising solution for high-throughput and automated cell imaging and classification in the ultrafast flow cytometer imaging platform.

  20. MR staging accuracy for endometrial cancer based on the new FIGO stage

    International Nuclear Information System (INIS)

    Shin, Kyung Eun; Park, Byung Kwan; Kim, Chan Kyo; Bae, Duk Soo; Song, Sang Yong; Kim, Bohyun

    2011-01-01

    Background: Magnetic resonance imaging (MRI) has been frequently used to determine a preoperative treatment plan for gynecologic cancers. However, the MR accuracy for staging an endometrial cancer is not satisfactory based on the old FIGO staging system. Purpose: To evaluate MR accuracy for staging endometrial cancer using the new FIGO staging system. Material and Methods: Between January 2005 and May 2009, 199 women underwent surgery due to endometrial cancer. In each patient, an endometrial cancer was staged using MR findings based on the old FIGO staging system and then repeated according to the new FIGO staging system for comparison. Histopathologic findings were used as a standard of reference. Results: The accuracy of MRI in the staging of endometrial carcinoma stage I, II, III, and IV using the old FIGO staging system were 80% (159/199), 89% (178/199), 90% (179/199), and 99% (198/199), respectively, compared to 87% (174/199), 97% (193/199), 90% (179/199), and 99% (198/199), respectively, when using the new FIGO staging criteria. The overall MR accuracy of the old and new staging systems were 51% (101/199) and 81% (161/199), respectively. Conclusion: MRI has become a more useful tool in the preoperative staging of endometrial cancers using the new FIGO staging system compared to the old one with increased accuracy

  1. Differential diagnosis and staging of urological tumors by magnetic resonance imaging compared with computed tomography

    International Nuclear Information System (INIS)

    Nishimura, Kazuo; Okada, Yusaku; Takeuchi, Hideo; Miyakawa, Mieko; Okada, Kenichiro; Yoshida, Osamu; Nishimura, Kazumasa

    1987-01-01

    Magnetic resonance imaging (MRI) was performed on 49 urological tumors (11 renal cell carcinomas, 3 renal pelvic cancers, 2 renal angiomyolipomas, 1 renal leiomyosarcoma, 1 large renal cvst, 4 adrenal tumors, 11 bladder cancers, 2 bone metastasis from bladder cancer, 10 prostatic cancers, 1 prostatic sarcoma, 1 urethral cancer, 1 penile cancer and 1 perivesical granuloma) since October 1985 to September 1986. MRI was performed using a Signa (G.E.) with a 1.5 T superconductive magnet and 3 images, including T1 weighted image, T2 weighted image, and proton density image, were obtained. In conclusion MRI is a noninvasive examination and gives more information than computed tomography despite its high cost. In renal cell carcinoma, the chemical shift in MRI and clear visualization of tumor thrombus enable accurate staging. Differential diagnosis from other renal mass lesions may be possible by the T2 weighted image. In adrenal disease, most of the adrenal masses can be differentiated, but in some cases it is impossible. In bladder cancer, wall invasion of tumor may be evaluated in T2 weighted image, and MRI is suitable for staging of locally advanced tumor. In prostatic cancer, visualization of periprostatic plexus and differentiation between internal and external gland may enable local staging and identification of low stage tumors. (author)

  2. Effectiveness of a Staged US and Unenhanced MR Imaging Algorithm in the Diagnosis of Pediatric Appendicitis.

    Science.gov (United States)

    Dibble, Elizabeth H; Swenson, David W; Cartagena, Claudia; Baird, Grayson L; Herliczek, Thaddeus W

    2018-03-01

    Purpose To establish, in a large cohort, the diagnostic performance of a staged algorithm involving ultrasonography (US) followed by conditional unenhanced magnetic resonance (MR) imaging for the imaging work-up of pediatric appendicitis. Materials and Methods A staged imaging algorithm in which US and unenhanced MR imaging were performed in pediatric patients suspected of having appendicitis was implemented at the authors' institution on January 1, 2011, with US as the initial modality followed by unenhanced MR imaging when US findings were equivocal. A search of the radiology database revealed 2180 pediatric patients who had undergone imaging for suspected appendicitis from January 1, 2011, through December 31, 2012. Of the 2180 patients, 1982 (90.9%) were evaluated according to the algorithm. The authors reviewed the electronic medical records and imaging reports for all patients. Imaging reports were reviewed and classified as positive, negative, or equivocal for appendicitis and correlated with surgical and pathology reports. Results The frequency of appendicitis was 20.5% (407 of 1982 patients). US alone was performed in 1905 of the 1982 patients (96.1%), yielding a sensitivity of 98.7% (386 of 391 patients) and specificity of 97.1% (1470 of 1514 patients) for appendicitis. Seventy-seven patients underwent unenhanced MR imaging after equivocal US findings, yielding an overall algorithm sensitivity of 98.2% (400 of 407 patients) and specificity of 97.1% (1530 of 1575 patients). Seven of the 1982 patients (0.4%) had false-negative results with the staged algorithm. The negative predictive value of the staged algorithm was 99.5% (1530 of 1537 patients). Conclusion A staged algorithm of US and unenhanced MR imaging for pediatric appendicitis appears to be effective. The results of this study demonstrate that this staged algorithm is 98.2% sensitive and 97.1% specific for the diagnosis of appendicitis in pediatric patients. © RSNA, 2017.

  3. Imaging Features of Helical Computed Tomography Suggesting Advanced Urothelial Carcinoma Arising from the Pelvocalyceal System

    International Nuclear Information System (INIS)

    Kwak, Kyung Won; Park, Byung Kwan; Kim, Chan Kyo; Lee, Hyun Moo; Choi, Han Y ong

    2008-01-01

    Background: Urothelial carcinoma is the most common malignant tumor arising from the pelvocalyceal system. Helical computed tomography (CT) is probably the best preoperative-stage modality for the determination of treatment plan and prognosis. Purpose: To obtain helical CT imaging features suggesting advanced pelvocalyceal urothelial carcinoma. Material and Methods: Preoperative CT images in 44 patients with pelvocalyceal urothelial carcinoma were retrospectively reviewed and correlated with the pathological examination to determine imaging features suggesting stage III or IV of the disease. Results: Pathological stages revealed stage I in 16, stage II in three, stage III in 17, and stage IV in eight patients. Seven patients had metastatic lymph nodes. CT imaging showed that renal parenchymal invasion, sinus fat invasion, and lymph node metastasis were highly suggestive of advanced urothelial cell carcinoma (P<0.05). Helical CT sensitivity, specificity, and accuracy for advanced pelvocalyceal urothelial carcinoma were 76% (19/25), 84% (16/19), and 80% (35/44), respectively. Conclusion: Preoperative helical CT may suggest imaging features of advanced urothelial carcinoma, influencing treatment plan and patient prognosis, even though its accuracy is not so high

  4. FDG-PET imaging for the staging and follow-up of small cell lung cancer

    International Nuclear Information System (INIS)

    Schumacher, T.; Brink, I.; Mix, M.; Reinhardt, M.; Moser, E.; Nitzsche, E.; Herget, G.; Digel, W.; Henke, M.

    2001-01-01

    The staging procedures for small cell lung cancer do not differ appreciably from those for other forms of lung cancer. For practical purposes, the TNM stages are usually collapsed into a simple binary classification: limited disease and extensive disease. This study was performed to answer the question of whether fluorine-18 labelled 2-deoxy-2-D-glucose positron emission tomography (FDG-PET) imaging permits appropriate work-up (including both primary and follow-up staging) of patients presenting with small cell lung cancer, as compared with currently recommended staging procedures. Thirty-six FDG-PET examinations were performed in 30 patients with histologically proven small cell lung cancer. Twenty-four patients were examined for primary staging while four were imaged for therapy follow-up only. Two patients underwent both primary staging and up to four examinations for therapy follow-up. Static PET imaging was performed according to a standard protocol. Image reconstruction was based on an ordered subset expectation maximization algorithm including post-injection segmented attenuation correction. Results of FDG-PET were compared with those of the sum of other staging procedures. Identical results from FDG-PET and the sum of the other staging procedures were obtained in 23 of 36 examinations (6 x limited disease, 12 x extensive disease, 5 x no evidence of disease). In contrast to the results of conventional staging, FDG-PET indicated extensive disease resulting in an up-staging in seven patients. In one patient in whom there was no evidence for tumour on conventional investigations following treatment, FDG-PET was suggestive of residual viability of the primary tumour. Furthermore, discordant results were observed in five patients with respect to lung, bone, liver and adrenal gland findings, although in these cases the results did not affect staging as limited or extensive disease. Moreover, FDG-PET appeared to be more sensitive for the detection of metastatic

  5. MR imaging features and staging of neuroendocrine carcinomas of the uterine cervix with pathological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Xiaohui; Zhang, Xiang; Hu, Huijun; Li, Guozhao; Wang, Dongye; Zhang, Fang; Shen, Jun [Sun Yat-Sen University, Department of Radiology, Sun Yat-Sen Memorial Hospital, Guangzhou (China); Ban, Xiaohua [Sun Yat-Sen University, Medical Imaging and Minimally Invasive Interventional Center and State Key Laboratory of Oncology in Southern China, Cancer Center, Guangzhou, Guangdong (China); Wang, Charles Qian [Sun Yat-Sen University, Department of Radiology, Sun Yat-Sen Memorial Hospital, Guangzhou (China); University of New South Wales, JMO, Westmead Hospital, Sydney (Australia)

    2016-12-15

    To determine MR imaging features and staging accuracy of neuroendocrine carcinomas (NECs) of the uterine cervix with pathological correlations. Twenty-six patients with histologically proven NECs, 60 patients with squamous cell carcinomas (SCCs), and 30 patients with adenocarcinomas of the uterine cervix were included. The clinical data, pathological findings, and MRI findings were reviewed retrospectively. MRI features of cervical NECs, SCCs, and adenocarcinomas were compared, and MRI staging of cervical NECs was compared with the pathological staging. Cervical NECs showed a higher tendency toward a homogeneous signal intensity on T2-weighted imaging and a homogeneous enhancement pattern, as well as a lower ADC value of tumour and a higher incidence of lymphadenopathy, compared with SCCs and adenocarcinomas (P < 0.05). An ADC value cutoff of 0.90 x 10{sup -3} mm{sup 2}/s was robust for differentiation between cervical NECs and other cervical cancers, with a sensitivity of 63.3 % and a specificity of 95 %. In 21 patients who underwent radical hysterectomy and lymphadenectomy, the overall accuracy of tumour staging by MR imaging was 85.7 % with reference to pathology staging. Homogeneous lesion texture and low ADC value are likely suggestive features of cervical NECs and MR imaging is reliable for the staging of cervical NECs. (orig.)

  6. Evaluation of carcinoma cervix using magnetic resonance imaging: correlation with clinical FIGO staging and impact on management

    International Nuclear Information System (INIS)

    Dhoot, Nilu Malpani; Bhuyan, Utpal; Kumar, Vinay; Shinagare, Atul; Kataki, Amal Chandra; Barmon, Debabrata

    2012-01-01

    To evaluate carcinoma of the cervix using magnetic resonance imaging (MRI), correlate with clinical approach of International Federation of Gynecology and Obstetrics (FIGO) staging system and to study the impact of MRI findings on patient management. Pathologically confirmed, 75 cases of carcinoma cervix referred to our institute from April 2007 to March 2008 were prospectively studied. Clinical FIGO stage was assigned to each patient by gynaecologists blinded to MRI findings. MRI stage (based on FIGO and TNM) was allotted by radiologists blinded to clinicopathological details. For patients who were operated, histopathological stage was taken as gold standard. For patients who were not operated, gynaecologists decided on a gold standard stage based on all available clinical and imaging data. MR staging was correlated with FIGO staging, with focus on significant alterations in treatment strategy caused due to MRI findings. MRI staging had an accuracy of 89.3% (67/75), while clinical FIGO staging had 61.3% (46/75) accuracy. MRI staging and FIGO staging concurred in 65.6% of the patients and differed in 34.4% of the patients. In about 30.6% (23/75) of the patients, there were relevant additional MRI findings not suspected clinically. The common significant MRI findings were detection of pelvic lymphadenopathy and clinically unsuspected bowel/bladder invasion. The management protocol was significantly altered in 86.9% (20/23) of the patients with additional MRI findings constituting 26.6% (20/75) of the total population. MRI is highly accurate in evaluating carcinoma of the cervix. MRI findings significantly altered therapeutic decisions in 26.6% of the patients. MRI should be considered prior to treatment planning in every patient.

  7. Detecting early stage pressure ulcer on dark skin using multispectral imager

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua; Sprigle, Stephen; Wang, Fengtao; Wang, Chao; Liu, Fuhan; Adibi, Ali; Tummala, Rao

    2010-02-01

    We are developing a handheld multispectral imaging device to non-invasively inspect stage I pressure ulcers in dark pigmented skins without the need of touching the patient's skin. This paper reports some preliminary test results of using a proof-of-concept prototype. It also talks about the innovation's impact to traditional multispectral imaging technologies and the fields that will potentially benefit from it.

  8. Robust algebraic image enhancement for intelligent control systems

    Science.gov (United States)

    Lerner, Bao-Ting; Morrelli, Michael

    1993-01-01

    Robust vision capability for intelligent control systems has been an elusive goal in image processing. The computationally intensive techniques a necessary for conventional image processing make real-time applications, such as object tracking and collision avoidance difficult. In order to endow an intelligent control system with the needed vision robustness, an adequate image enhancement subsystem capable of compensating for the wide variety of real-world degradations, must exist between the image capturing and the object recognition subsystems. This enhancement stage must be adaptive and must operate with consistency in the presence of both statistical and shape-based noise. To deal with this problem, we have developed an innovative algebraic approach which provides a sound mathematical framework for image representation and manipulation. Our image model provides a natural platform from which to pursue dynamic scene analysis, and its incorporation into a vision system would serve as the front-end to an intelligent control system. We have developed a unique polynomial representation of gray level imagery and applied this representation to develop polynomial operators on complex gray level scenes. This approach is highly advantageous since polynomials can be manipulated very easily, and are readily understood, thus providing a very convenient environment for image processing. Our model presents a highly structured and compact algebraic representation of grey-level images which can be viewed as fuzzy sets.

  9. Ovarian chocolate cysts. Staging with relaxation time in MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sugimura, Kazuro; Ishida, Tetsuya; Takemori, Masayuki; Kitagaki, Hajime; Tanaka, Yutaka; Yamasaki, Katsuhito; Shimizu, Tadafumi; Kono, Michio

    1988-10-01

    Accurate preoperative staging of ovarian chocolate cysts is very important because recent hormonal therapy has been effective in low stage patients. However, it has been difficult to assess the preoperative stage of ovarian chocolate cysts. We evaluated the diagnostic potential of MRI in preoperative staging of 15 overian chocolate cysts. It was well known that the older the ovarian chocolate cyst was the more iron content it had. We examined the iron contents effect on T1 and T2 relaxation times in surgically confirmed chocolate cysts (stage II: 3 cases, stage III: 3 cases and stage IV: 9 cases by AFS classification, 1985) employing the 0.15-T MR system and 200 MHz spectrometer. There was a positive linear relation between T1 of the lesion using the MR system (T1) and T1 of the resected contents using the spectrometer (sp-T1); r = 0.93. The same relation was revealed between T2 and sp-T2; r = 0.87. It was indicated that T1 and T2 using the MR system was accurate. There was a negative linear relation between T1 and the iron contents ( r = -0.81) but no relation between T2 and the iron contents. T1 was 412 +- 91 msec for stage II, 356 +- 126 msec for stage III and 208 +- 30 msec for stage IV. T1 for stage IV was shorter than that for stage II and III, statistically significant differences were noted (p < 0.05). Thus, T1 was useful in differentiating a fresh from an old ovarian chocolate cyst. We concluded that T1 relaxation time using the MR system was useful for the staging of an ovarian chocolate cyst without surgery.

  10. Comparative study of nasopharyngeal carcinoma staging system between the chinese 2008 and '92 Fuzhou

    International Nuclear Information System (INIS)

    Zong Jingfeng; Lin Shaojun; Zhang Yu; Chen Yunbin; Guo Qiaojuan; Pan Jianji

    2010-01-01

    Objective: To carry out a comparative study between the Chinese 2008 and '92 staging system of nasopharyngeal carcinoma (NPC). Methods: A total of 777 patients presented with untreated non disseminated NPC who had received MRI scan of nasopharynx and neck were studied retrospectively. The clinical materials and information of imaging were collected. All patients were restaged according to the Chinese 2008 and 92 staging system of nasopharyngeal carcinoma. Distribution of T, N stage, survival and prognostic value were compared. 513 patients of the 777 cases were treated with conventional radiotherapy, 264 cases with intensity modulated radiation therapy. Results: The 3-year follow-up rate was 97.6%. The consistency of T stages was 95.0%. T, N and clinical stage distributions in two systems were similar ( Kappa = 0.93, P = 0.000; Kappa = 0.58, P = 0.000; Kappa = 0.74, P = 0.000). Local failure-free survival and disease specific survival were also similar. There was no difference of distant metastasis between N 0 and N 1 (χ 2 = 1.94, P=0. 164), and a marginal difference between N 1 and N 2 (χ 2 =3.83, P=0.051) in the Chinese '92 staging system. However, although there was also no difference of distant metastasis-free survival between N 0 and N 1a (χ 2 =0.07, P =0.797), ) the difference of overall survival among N 1b , N 2 , and N 3 were significant (χ 2 = 4.95, P = 0.026; χ 2 = 6.74, P = 0.009) in the Chinese 2008 staging system. Conventional radiotherapy or intensity modulated radiation therapy was not a prognostic factor for survival (χ 2 = 3.60, P =0.058). It is reasonable for the Chinese 2008 staging system integrated lymph node characteristics such as laterality, level and extra nodal neoplastic spread into the N staging criteria (χ 2 = 6.59, P = 0.010; χ 2 =4.78, P=0. 029; χ 2 =9.32, P=0.002). Conclusions: For the Chinese 2008 staging system, it was reasonable to simplify the previous T stage. The N stage showed a better predictive role of distant

  11. Staging of pancreatic ductal adenocarcinoma using dynamic MR imaging

    International Nuclear Information System (INIS)

    Murakami, Kouji; Nawano, Shigeru; Moriyama, Noriyuki; Sekiguchi, Ryuzou; Satake, Mituo; Iwata, Ryouko; Hayashi, Takayuki; Nemoto, Kazuhisa.

    1997-01-01

    Single breath-hold gradient echo images were obtained before and immediately after bolus intravenous administration of Gd-DTPA (dynamic MR imaging) in the study of the pancreas. Of 37 patients with pathologically proved pancreatic ductal adenocarcinoma, seventeen patients who underwent both dynamic MR imaging studies and curative surgery were included in this study. Correlations between histologic findings in the resected specimens and MR images were analyzed as to tumor extension and staging according to the General Rules for the Study of Pancreatic Cancer (4th Edition) published by the Japan Pancreas Society. In comparison with conventional MR images, dynamic MR imaging improved the detectability of pancreatic carcinoma and delineation of the vasculature by clarifying the margin of the tumor and the vessels. Nonenhanced T1-weighted imaging is the best sequence to estimate peripancreatic tumor extension, because the contrast between the tumor and peripancreatic fat deteriorates with the use of contrast material. There is a tendency to overestimate vascular invasion on MR images, the reason for which is considered to be the contractive nature of fibrotic change induced by pancreatic carcinoma. The diagnostic efficacy of lymph node metastasis remains insufficient on MR images because some cases show no enlargement of lymph nodes in spite of the existence of pathological metastasis. Our results suggest that dynamic MR imaging has the advantage of improving the conspicuity of the tumor and the vasculature. (author)

  12. Experimental image alignment system

    Science.gov (United States)

    Moyer, A. L.; Kowel, S. T.; Kornreich, P. G.

    1980-01-01

    A microcomputer-based instrument for image alignment with respect to a reference image is described which uses the DEFT sensor (Direct Electronic Fourier Transform) for image sensing and preprocessing. The instrument alignment algorithm which uses the two-dimensional Fourier transform as input is also described. It generates signals used to steer the stage carrying the test image into the correct orientation. This algorithm has computational advantages over algorithms which use image intensity data as input and is suitable for a microcomputer-based instrument since the two-dimensional Fourier transform is provided by the DEFT sensor.

  13. Development of CCD Imaging System Using Thermoelectric Cooling Method

    Directory of Open Access Journals (Sweden)

    Youngsik Park

    2000-06-01

    Full Text Available We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E (768x512 pixels CCD chip,thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of -25deg. We employed an Uniblitz VS25S shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of -10deg, a linearity 99.9+/-0.1%, gain 4.24e-adu, and system noise is 25.3e- (rms. For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry (+/-0.01mag even though the CCD is not at 'conventional' cryogenic temperatures (140K. The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  14. Implementation of webcam-based hyperspectral imaging system

    Science.gov (United States)

    Balooch, Ali; Nazeri, Majid; Abbasi, Hamed

    2018-02-01

    In the present work, a hyperspectral imaging system (imaging spectrometer) using a commercial webcam has been designed and developed. This system was able to capture two-dimensional spectra (in emission, transmission and reflection modes) directly from the scene in the desired wavelengths. Imaging of the object is done directly by linear sweep (pushbroom method). To do so, the spectrometer is equipped with a suitable collecting lens and a linear travel stage. A 1920 x 1080 pixel CMOS webcam was used as a detector. The spectrometer has been calibrated by the reference spectral lines of standard lamps. The spectral resolution of this system was about 2nm and its spatial resolution was about 1 mm for a 10 cm long object. The hardware solution is based on data acquisition working on the USB platform and controlled by a LabVIEW program. In this system, the initial output was a three-dimensional matrix in which two dimensions of the matrix were related to the spatial information of the object and the third dimension was the spectrum of any point of the object. Finally, the images in different wavelengths were created by reforming the data of the matrix. The free spectral range (FSR) of the system was 400 to 1100 nm. The system was successfully tested for some applications, such as plasma diagnosis as well as applications in food and agriculture sciences.

  15. {sup 18}F-FDG-PET/CT for systemic staging of newly diagnosed triple-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ulaner, Gary A.; Castillo, Raychel; Riedl, Christopher C.; Jochelson, Maxine S. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Goldman, Debra A.; Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Wills, Jonathan [Memorial Sloan Kettering Cancer Center, Department of Information Systems, New York, NY (United States); Pinker-Domenig, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States)

    2016-10-15

    National Comprehensive Cancer Network guidelines recommend {sup 18}F-FDG-PET/CT, in addition to standard staging procedures, for systemic staging of newly diagnosed stage III breast cancer patients. However, factors in addition to stage may influence PET/CT utility. As breast cancers that are negative for estrogen receptor, progesterone receptor, and human epidermal growth factor receptor (triple-negative breast cancer, or TNBC) are more aggressive and metastasize earlier than other breast cancers, we hypothesized that receptor expression may be one such factor. This study assesses {sup 18}F-FDG-PET/CT for systemic staging of newly diagnosed TNBC. In this Institutional Review Board-approved retrospective study, our Healthcare Information System was screened for patients with TNBC who underwent {sup 18}F-FDG-PET/CT in 2007-2013 prior to systemic or radiation therapy. Initial stage was determined from mammography, ultrasound, magnetic resonance imaging, and/or surgery, if performed prior to {sup 18}F-FDG-PET/CT. {sup 18}F-FDG-PET/CT was evaluated to identify unsuspected extra-axillary regional nodal and distant metastases, as well as unsuspected synchronous malignancies. Kaplan Meier survival estimates were calculated for initial stage IIB patients stratified by whether or not stage 4 disease was detected by {sup 18}F-FDG-PET/CT. A total of 232 patients with TNBC met inclusion criteria. {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 30 (13 %): 0/23 initial stage I, 4/82 (5 %) stage IIA, 13/87 (15 %) stage IIB, 4/23 (17 %) stage IIIA, 8/14 (57 %) stage IIIB, and 1/3 (33 %) stage IIIC. Twenty-six of 30 patients upstaged to IV by {sup 18}F-FDG-PET/CT were confirmed by pathology, with the remaining four patients confirmed by follow-up imaging. In addition, seven unsuspected synchronous malignancies were identified in six patients. Initial stage 2B patients who were upstaged to 4 by {sup 18}F-FDG-PET/CT had significantly shorter survival compared to

  16. Myometrial invasion and overall staging of endometrial carcinoma: assessment using fusion of T2-weighted magnetic resonance imaging and diffusion-weighted magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Guo Y

    2017-12-01

    Full Text Available Yu Guo,1,2 Ping Wang,2 Penghui Wang,2 Wei Gao,1 Fenge Li,3 Xueling Yang,1 Hongyan Ni,2 Wen Shen,2 Zhi Guo1 1Department of Interventional Therapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin’s Clinical Research Center for Cancer, Tianjin, 2Department of Radiology, Tianjin First Center Hospital, The First Central Clinical College of Tianjin Medical University, Tianjin, 3Department of Gynecology, Tianjin First Center Hospital, Tianjin, People’s Republic of China Background: The age of onset of endometrial carcinoma has been decreasing in recent years. In endometrial carcinoma, it is important to accurately assess invasion depth and preoperative staging. Fusion of T2-weighted magnetic resonance imaging (T2WI and diffusion-weighted magnetic resonance imaging (DWI may contribute to the improvement of anatomical localization of lesions.Materials and methods: In our study, a total of 58 endometrial carcinoma cases were included. Based on the revised 2009 International Federation of Gynecology and Obstetrics staging system, a fusion of T2WI and DWI was utilized for the evaluation of invasion depth and determination of the overall stage. Postoperative pathologic assessment was considered as the reference standard. The consistency of T2WI image staging and pathologic staging, and the consistency of fused T2WI and DWI and pathologic staging were all analyzed using Kappa statistics.Results: Compared with the T2WI group, a significantly higher diagnostic accuracy was observed for myometrial invasion with fusion of T2WI and DWI (77.6% for T2WI; 94.8% for T2WI-DWI. For the identification of deep invasion, we calculated values for diagnostic sensitivity (69.2% for T2WI; 92.3% for T2WI-DWI, specificity (80% for T2WI; 95.6% for T2WI-DWI, positive predictive value (50% for T2WI; 85.7% for T2WI-DWI, and negative predictive value (90% for

  17. MR staging of endometrial carcinoma

    International Nuclear Information System (INIS)

    Innocenti, P.; Agostini, S.; Erroi, C.; Ambrogetti, D.; Cellerini, A.; Nori, J.

    1991-01-01

    Biopsy is the technique of choice for the definitive diagnosis of endometrial carcinoma. Since lymphatic tumor spread has been demonstrated to depend on the degree of myometrial involvement, the definition of the latter with imaging techniques may significantly affect both pfognosis and therapy. We investigated, by means of MR imaging at 0.5 T, 14 patients with endometrial carcinoma, to assess both tumor stage and myometrial involvement. FIGO staging system was employed, and M parameter evaluated (M0= no myometrial involvement; M1involvement confined to the inner third; M2= Involvement confined to the middle third; M3= involvement of the whole myometrium). Another parameter was the characteristic high signal of the tumor on PD and T2W images. The patients were then operated and MR information was correlated with surgical findings. Overall diagnostic accuracy of MR imaging was 85.7% in tumor staging, and 92.2% in defining M parameter. Tumor spread into adnexa and into cervical canal was poorly demonstrated by MR imaging

  18. Passive millimeter wave imaging and spectroscopy system for terrestrial remote sensing

    Science.gov (United States)

    Gopalsami, Nachappa; Liao, Shaolin; Koehl, Eugene R.; Elmer, Thomas W.; Heifetz, Alexander; Chien, Hual-Te; Raptis, Apostolos C.

    2010-04-01

    We have built a passive millimeter wave imaging and spectroscopy system with a 15-channel filter bank in the 146-154 GHz band for terrestrial remote sensing. We had built the spectroscopy system first and have now retrofitted an imaging element to it as a single pixel imager. The imaging element consisted of a 15-cm-diameter imaging lens fed to a corrugated scalar horn. Image acquisition is carried out by scanning the lens with a 2-axis translation stage. A LabVIEW-based software program integrates the imaging and spectroscopy systems with online display of spectroscopic information while the system scans each pixel position. The software also allows for integrating the image intensity of all 15 channels to increase the signal-to-noise ratio by a factor of ~4 relative to single channel image. The integrated imaging and spectroscopy system produces essentially 4-D data in which spatial data are along 2 dimensions, spectral data are in the 3rd dimension, and time is the 4th dimension. The system performance was tested by collecting imaging and spectral data with a 7.5-cm-diameter and 1m long gas cell in which test chemicals were introduced against a liquid nitrogen background.

  19. Magnetic resonance imaging in acute stage of cerebral ischemia

    International Nuclear Information System (INIS)

    Yamagata, Sen; Kikuchi, Haruhiko; Ihara, Ikuo

    1986-01-01

    The value of the nuclear magnetic resonance image (MRI) was investigated in the acute stage of experimental cerebral ischemia. The MRI system employed was designed for clinical use, and the superconducting magnet was operated at a field strength of 1.5 tesla. Ischemic insult was made by transorbital occlusion of the middle cerebral artery (MCA) permanently in 4 cats and temporarily in 2 cats. After MCA occlusion the regional cerebral blood flow (rCBF) was measured on the affected cortex, and 5 cats with rCBF below 10 ml/100 g/min and one with rCBF over 15 ml/100 g/min were studied. In the permanent occlusion group, MRI was performed every 2 hours from 4 to 12 hours after MCA occlusion and another MRI was carried out 20 min after gadolinium-diethylenetriamine-pentaacetic acid (Gd-DTPA) intravenous administration. The earliest changes were found 6 to 8 hours after MCA occlusion on the spin echo image (repetition time = 1.4 sec, echo time = 70 msec) in 3 cats with severe ischemia. It was postulated that the ischemic lesion could be depicted less than 6 hours on more T 2 -weighted images. The increased intensity area was markedly enhanced with Gd-DTPA 12 hours after occlusion. In the recirculation group, the increased intensity area was observed on enhanced MRI in a cat with recirculation as early as one hour after MCA occlusion, although it was not found on the plain MRI. In the other cat with recirculation after 2 hours' occlusion, definite lesion was found in all parameter images without enhancement. The results suggest that changes in cerebral ischemia can be obtained on the MRI earlier than X-ray computed tomography, and that it may be possible to determine the severity of the ischemic brain injury by the MRI findings. (author)

  20. Staged membrane oxidation reactor system

    Science.gov (United States)

    Repasky, John Michael; Carolan, Michael Francis; Stein, VanEric Edward; Chen, Christopher Ming-Poh

    2012-09-11

    Ion transport membrane oxidation system comprising (a) two or more membrane oxidation stages, each stage comprising a reactant zone, an oxidant zone, one or more ion transport membranes separating the reactant zone from the oxidant zone, a reactant gas inlet region, a reactant gas outlet region, an oxidant gas inlet region, and an oxidant gas outlet region; (b) an interstage reactant gas flow path disposed between each pair of membrane oxidation stages and adapted to place the reactant gas outlet region of a first stage of the pair in flow communication with the reactant gas inlet region of a second stage of the pair; and (c) one or more reactant interstage feed gas lines, each line being in flow communication with any interstage reactant gas flow path or with the reactant zone of any membrane oxidation stage receiving interstage reactant gas.

  1. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  2. Application of multispectral imaging to determine quality attributes and ripeness stage in strawberry fruit.

    Directory of Open Access Journals (Sweden)

    Changhong Liu

    Full Text Available Multispectral imaging with 19 wavelengths in the range of 405-970 nm has been evaluated for nondestructive determination of firmness, total soluble solids (TSS content and ripeness stage in strawberry fruit. Several analysis approaches, including partial least squares (PLS, support vector machine (SVM and back propagation neural network (BPNN, were applied to develop theoretical models for predicting the firmness and TSS of intact strawberry fruit. Compared with PLS and SVM, BPNN considerably improved the performance of multispectral imaging for predicting firmness and total soluble solids content with the correlation coefficient (r of 0.94 and 0.83, SEP of 0.375 and 0.573, and bias of 0.035 and 0.056, respectively. Subsequently, the ability of multispectral imaging technology to classify fruit based on ripeness stage was tested using SVM and principal component analysis-back propagation neural network (PCA-BPNN models. The higher classification accuracy of 100% was achieved using SVM model. Moreover, the results of all these models demonstrated that the VIS parts of the spectra were the main contributor to the determination of firmness, TSS content estimation and classification of ripeness stage in strawberry fruit. These results suggest that multispectral imaging, together with suitable analysis model, is a promising technology for rapid estimation of quality attributes and classification of ripeness stage in strawberry fruit.

  3. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  4. How I report breast magnetic resonance imaging studies for breast cancer staging and screening.

    Science.gov (United States)

    Vinnicombe, Sarah

    2016-07-25

    Magnetic resonance imaging (MRI) of the breast is the most sensitive imaging technique for the diagnosis and local staging of primary breast cancer and yet, despite the fact that it has been in use for 20 years, there is little evidence that its widespread uncritical adoption has had a positive impact on patient-related outcomes.This has been attributed previously to the low specificity that might be expected with such a sensitive modality, but with modern techniques and protocols, the specificity and positive predictive value for malignancy can exceed that of breast ultrasound and mammography. A more likely explanation is that historically, clinicians have acted on MRI findings and altered surgical plans without prior histological confirmation. Furthermore, modern adjuvant therapy for breast cancer has improved so much that it has become a very tall order to show a an improvement in outcomes such as local recurrence rates.In order to obtain clinically useful information, it is necessary to understand the strengths and weaknesses of the technique and the physiological processes reflected in breast MRI. An appropriate indication for the scan, proper patient preparation and good scan technique, with rigorous quality assurance, are all essential prerequisites for a diagnostically relevant study.The use of recognised descriptors from a standardised lexicon is helpful, since assessment can then dictate subsequent recommendations for management, as in the American College of Radiology BI-RADS (Breast Imaging Reporting and Data System) lexicon (Morris et al., ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System, 2013). It also enables audit of the service. However, perhaps the most critical factor in the generation of a meaningful report is for the reporting radiologist to have a thorough understanding of the clinical question and of the findings that will influence management. This has never been more important than at present, when we are in the throes of a

  5. Lock-in thermal imaging for the early-stage detection of cutaneous melanoma: a feasibility study.

    Science.gov (United States)

    Bonmarin, Mathias; Le Gal, Frédérique-Anne

    2014-04-01

    This paper theoretically evaluates lock-in thermal imaging for the early-stage detection of cutaneous melanoma. Lock-in thermal imaging is based on the periodic thermal excitation of the specimen under test. Resulting surface temperature oscillations are recorded with an infrared camera and allow the detection of variations of the sample's thermophysical properties under the surface. In this paper, the steady-state and transient skin surface temperatures are numerically derived for a different stage of development of the melanoma lesion using a two-dimensional axisymmetric multilayer heat-transfer model. The transient skin surface temperature signals are demodulated according to the digital lock-in principle to compute both a phase and an amplitude image of the lesions. The phase image can be advantageously used to accurately detect cutaneous melanoma at an early stage of development while the maximal phase shift can give precious information about the lesion invasion depth. The ability of lock-in thermal imaging to suppress disturbing subcutaneous thermal signals is demonstrated. The method is compared with the previously proposed pulse-based approaches, and the influence of the modulation frequency is further discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Suppression of fixed pattern noise for infrared image system

    Science.gov (United States)

    Park, Changhan; Han, Jungsoo; Bae, Kyung-Hoon

    2008-04-01

    In this paper, we propose suppression of fixed pattern noise (FPN) and compensation of soft defect for improvement of object tracking in cooled staring infrared focal plane array (IRFPA) imaging system. FPN appears an observable image which applies to non-uniformity compensation (NUC) by temperature. Soft defect appears glittering black and white point by characteristics of non-uniformity for IR detector by time. This problem is very important because it happen serious problem for object tracking as well as degradation for image quality. Signal processing architecture in cooled staring IRFPA imaging system consists of three tables: low, normal, high temperature for reference gain and offset values. Proposed method operates two offset tables for each table. This is method which operates six term of temperature on the whole. Proposed method of soft defect compensation consists of three stages: (1) separates sub-image for an image, (2) decides a motion distribution of object between each sub-image, (3) analyzes for statistical characteristic from each stationary fixed pixel. Based on experimental results, the proposed method shows an improved image which suppresses FPN by change of temperature distribution from an observational image in real-time.

  7. A high-resolution optical imaging system for obtaining the serial transverse section images of biologic tissue

    Science.gov (United States)

    Wu, Li; Zhang, Bin; Wu, Ping; Liu, Qian; Gong, Hui

    2007-05-01

    A high-resolution optical imaging system was designed and developed to obtain the serial transverse section images of the biologic tissue, such as the mouse brain, in which new knife-edge imaging technology, high-speed and high-sensitive line-scan CCD and linear air bearing stages were adopted and incorporated with an OLYMPUS microscope. The section images on the tip of the knife-edge were synchronously captured by the reflection imaging in the microscope while cutting the biologic tissue. The biologic tissue can be sectioned at interval of 250 nm with the same resolution of the transverse section images obtained in x and y plane. And the cutting job can be automatically finished based on the control program wrote specially in advance, so we save the mass labor of the registration of the vast images data. In addition, by using this system a larger sample can be cut than conventional ultramicrotome so as to avoid the loss of the tissue structure information because of splitting the tissue sample to meet the size request of the ultramicrotome.

  8. Computerized breast cancer analysis system using three stage semi-supervised learning method.

    Science.gov (United States)

    Sun, Wenqing; Tseng, Tzu-Liang Bill; Zhang, Jianying; Qian, Wei

    2016-10-01

    A large number of labeled medical image data is usually a requirement to train a well-performed computer-aided detection (CAD) system. But the process of data labeling is time consuming, and potential ethical and logistical problems may also present complications. As a result, incorporating unlabeled data into CAD system can be a feasible way to combat these obstacles. In this study we developed a three stage semi-supervised learning (SSL) scheme that combines a small amount of labeled data and larger amount of unlabeled data. The scheme was modified on our existing CAD system using the following three stages: data weighing, feature selection, and newly proposed dividing co-training data labeling algorithm. Global density asymmetry features were incorporated to the feature pool to reduce the false positive rate. Area under the curve (AUC) and accuracy were computed using 10 fold cross validation method to evaluate the performance of our CAD system. The image dataset includes mammograms from 400 women who underwent routine screening examinations, and each pair contains either two cranio-caudal (CC) or two mediolateral-oblique (MLO) view mammograms from the right and the left breasts. From these mammograms 512 regions were extracted and used in this study, and among them 90 regions were treated as labeled while the rest were treated as unlabeled. Using our proposed scheme, the highest AUC observed in our research was 0.841, which included the 90 labeled data and all the unlabeled data. It was 7.4% higher than using labeled data only. With the increasing amount of labeled data, AUC difference between using mixed data and using labeled data only reached its peak when the amount of labeled data was around 60. This study demonstrated that our proposed three stage semi-supervised learning can improve the CAD performance by incorporating unlabeled data. Using unlabeled data is promising in computerized cancer research and may have a significant impact for future CAD system

  9. Urinary bladder cancer T-staging from T2-weighted MR images using an optimal biomarker approach

    Science.gov (United States)

    Wang, Chuang; Udupa, Jayaram K.; Tong, Yubing; Chen, Jerry; Venigalla, Sriram; Odhner, Dewey; Guzzo, Thomas J.; Christodouleas, John; Torigian, Drew A.

    2018-02-01

    Magnetic resonance imaging (MRI) is often used in clinical practice to stage patients with bladder cancer to help plan treatment. However, qualitative assessment of MR images is prone to inaccuracies, adversely affecting patient outcomes. In this paper, T2-weighted MR image-based quantitative features were extracted from the bladder wall in 65 patients with bladder cancer to classify them into two primary tumor (T) stage groups: group 1 - T stage T2, with primary tumor locally confined to the bladder, and group 2 - T stage T2, with primary tumor locally extending beyond the bladder. The bladder was divided into 8 sectors in the axial plane, where each sector has a corresponding reference standard T stage that is based on expert radiology qualitative MR image review and histopathologic results. The performance of the classification for correct assignment of T stage grouping was then evaluated at both the patient level and the sector level. Each bladder sector was divided into 3 shells (inner, middle, and outer), and 15,834 features including intensity features and texture features from local binary pattern and gray-level co-occurrence matrix were extracted from the 3 shells of each sector. An optimal feature set was selected from all features using an optimal biomarker approach. Nine optimal biomarker features were derived based on texture properties from the middle shell, with an area under the ROC curve of AUC value at the sector and patient level of 0.813 and 0.806, respectively.

  10. Health economics evaluation of magnetic resonance imaging for the staging of prostate cancer for Austria and Germany

    International Nuclear Information System (INIS)

    Stadlbauer, A.; Erlangen-Nuernberg Univ., Erlangen; Bernt, R.; Salomonowitz, E.; Plas, E.; Strunk, G.; Eberhardt, K.

    2012-01-01

    Purpose: The aim of this study was the health economics analysis of MR imaging in the preoperative staging of patients with prostate carcinoma (PCa). Materials and Methods: The health economics analysis consisted of the following steps: modeling, determination of probabilities and parameters based on a detailed literature search, evaluation using the averages of the parameters, and sensitivity analyses of the results over the ranges of values. We performed a cost-utility analysis from health insurance's perspective for Austria and Germany. The population under investigation included patients with confirmed PCa. The alternative was a decision for therapy with or without staging using MR imaging. A localized PCa was treated by prostatectomy and locally advanced PCa by radiation/hormone therapy. The result parameters were quality adjusted life years (QALYs) and costs per patient. Results: The evaluation showed that MR imaging is useful regarding costs and utilities prior to radical prostatectomy which is expensive and may be associated with serious clinical consequences. The costs per patient were lower by Euro 2635 and the utilities were higher by 0.099 QALYs. The strategy without MR imaging for staging was dominated by the strategy using MR imaging for staging in the evaluation using the base values and in almost all sensitivity analyses. Conclusion: For the parameters used and almost all scenarios of the sensitivity analysis, our decision-analytic model revealed a higher cost-utility ratio for the strategy using MR imaging for the staging of PCa. (orig.)

  11. Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performance.

    NARCIS (Netherlands)

    Heijmink, S.W.T.P.J.; Futterer, J.J.; Hambrock, T.; Takahashi, S.; Scheenen, T.W.J.; Huisman, H.J.; Hulsbergen-van de Kaa, C.A.; Knipscheer, B.C.; Kiemeney, L.A.L.M.; Witjes, J.A.; Barentsz, J.O.

    2007-01-01

    PURPOSE: To prospectively compare image quality and accuracy of prostate cancer localization and staging with body-array coil (BAC) versus endorectal coil (ERC) T2-weighted magnetic resonance (MR) imaging at 3 T, with histopathologic findings as the reference standard. MATERIALS AND METHODS: After

  12. A small animal image guided irradiation system study using 3D dosimeters

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Admovics, John

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies

  13. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  14. TRIO Platform: A novel low profile in vivo imaging support and restraint system for mice

    Directory of Open Access Journals (Sweden)

    Vladislav eVoziyanov

    2016-04-01

    Full Text Available High resolution, in vivo optical imaging of the mouse brain over time often requires anesthesia, which necessitates maintaining the animal's body temperature and level of anesthesia, as well as securing the head in an optimal, stable position. Controlling each parameter usually requires using multiple systems. Assembling multiple components into the small space on a standard microscope stage can be difficult and some commercially available parts simply do not fit. Furthermore, it is time-consuming to position an animal in the identical position over multiple imaging sessions for longitudinal studies. This is especially true when using an implanted gradient index (GRIN lens for deep brain imaging. The multiphoton laser beam must be parallel with the shaft of the lens because even a slight tilt of the lens can degrade image quality. In response to these challenges, we have designed a compact, integrated in vivo imaging support system to overcome the problems created by using separate systems during optical imaging in mice. It is a single platform that provides (1 sturdy head fixation, (2 an integrated gas anesthesia mask, and (3 safe warm water heating. This THREE-IN-ONE (TRIO Platform has a small footprint and a low profile that positions a mouse’s head only 20 mm above the microscope stage. This height is about one half to one third the height of most commercially available immobilization devices. We have successfully employed this system, using isoflurane in over 40 imaging sessions with an average of 2 h per session with no leaks or other malfunctions. Due to its smaller size, the TRIO Platform can be used with a wider range of upright microscopes and stages. Most of the components were designed in SOLIDWORKS® and fabricated using a 3D printer. This additive manufacturing approach also readily permits size modifications for creating systems for other small animals.

  15. TRIO Platform: A Novel Low Profile In vivo Imaging Support and Restraint System for Mice.

    Science.gov (United States)

    Voziyanov, Vladislav; Kemp, Benjamin S; Dressel, Chelsea A; Ponder, Kayla; Murray, Teresa A

    2016-01-01

    High resolution, in vivo optical imaging of the mouse brain over time often requires anesthesia, which necessitates maintaining the animal's body temperature and level of anesthesia, as well as securing the head in an optimal, stable position. Controlling each parameter usually requires using multiple systems. Assembling multiple components into the small space on a standard microscope stage can be difficult and some commercially available parts simply do not fit. Furthermore, it is time-consuming to position an animal in the identical position over multiple imaging sessions for longitudinal studies. This is especially true when using an implanted gradient index (GRIN) lens for deep brain imaging. The multiphoton laser beam must be parallel with the shaft of the lens because even a slight tilt of the lens can degrade image quality. In response to these challenges, we have designed a compact, integrated in vivo imaging support system to overcome the problems created by using separate systems during optical imaging in mice. It is a single platform that provides (1) sturdy head fixation, (2) an integrated gas anesthesia mask, and (3) safe warm water heating. This THREE-IN-ONE (TRIO) Platform has a small footprint and a low profile that positions a mouse's head only 20 mm above the microscope stage. This height is about one half to one third the height of most commercially available immobilization devices. We have successfully employed this system, using isoflurane in over 40 imaging sessions with an average of 2 h per session with no leaks or other malfunctions. Due to its smaller size, the TRIO Platform can be used with a wider range of upright microscopes and stages. Most of the components were designed in SOLIDWORKS® and fabricated using a 3D printer. This additive manufacturing approach also readily permits size modifications for creating systems for other small animals.

  16. Diversity of imaging and pathological features at different stages of primary central nervous system lymphoma

    Directory of Open Access Journals (Sweden)

    Jing LIU

    2018-01-01

    Full Text Available Objective The clinical, imaging and pathological manifestations of one patient at different stages of primary central nervous system lymphoma (PCNSL have been analyzed to disclose its pathogenesis. Methods and Results A 29-year-old female patient showed recurrent onsets. On the first onset, the main clinical manifestation was blurred vision and visual field defect. Cranial MRI showed a patchy lesion in the right parietal and occipital lobes without obvious occupying sign. T1WI showed slight low-intensity sign, T2WI and FLAIR showed high-intensity signs. Enhanced scanning showed heterogeneous punctate enhancement. The lesion disappeared gradually after glucocorticoid impact therapy. Headache, vomiting and left limb paralysis were the main clinical manifestations on the second onset, and MRI showed a lesion in the right frontal and parietal lobes with obvious occupying sign and solid enhancement, low-intensity on T1WI, high-intensity on T2WI and FLAIR. The tumor was totally removed under microscope. Histological findings showed large tumor cells, rich cytoplasm, nuclei with various sizes and shapes, conspicuous mitosis, patchy necrosis, and interstitial small vessel hyperplasia. Immunohistochemical staining showed that membrane of tumor cells was positive for CD20, and nuclei were positive for paired box gene 5 (PAX5 and multiple myeloma oncogene 1 (MUM1. In a few tumor cells, membrane was positive for CD10 and CD30, and nuclei were positive for cyclin D1. Besides, tumor cells were negative for CD3, anaplastic lymphoma kinase (ALK and glial fibrillary acidic protein (GFAP. Ki?67 labeling index was about 80%. EBER in situ hybridization (ISH assay showed that mRNA coded by Epstein?Barr (EB virus was negative. The tumor showed angiotropic characteristics, and the walls of involved blood vessels were wrapped and destructed. The final diagnosis was confirmed as diffuse large B cell lymphoma. Conclusions PCNSL has various imaging features, revealing as

  17. Expandable image compression system: A modular approach

    International Nuclear Information System (INIS)

    Ho, B.K.T.; Chan, K.K.; Ishimitsu, Y.; Lo, S.C.; Huang, H.K.

    1987-01-01

    The full-frame bit allocation algorithm for radiological image compression developed in the authors' laboratory can achieve compression ratios as high as 30:1. The software development and clinical evaluation of this algorithm has been completed. It involves two stages of operations: a two-dimensional discrete cosine transform and pixel quantization in the transform space with pixel depth kept accountable by a bit allocation table. Their design took an expandable modular approach based on the VME bus system which has a maximum data transfer rate of 48 Mbytes per second and a Motorola 68020 microprocessor as the master controller. The transform modules are based on advanced digital signal processor (DSP) chips microprogrammed to perform fast cosine transforms. Four DSP's built into a single-board transform module can process an 1K x 1K image in 1.7 seconds. Additional transform modules working in parallel can be added if even greater speeds are desired. The flexibility inherent in the microcode extends the capabilities of the system to incorporate images of variable sizes. Their design allows for a maximum image size of 2K x 2K

  18. Image-based fingerprint verification system using LabVIEW

    Directory of Open Access Journals (Sweden)

    Sunil K. Singla

    2008-09-01

    Full Text Available Biometric-based identification/verification systems provide a solution to the security concerns in the modern world where machine is replacing human in every aspect of life. Fingerprints, because of their uniqueness, are the most widely used and highly accepted biometrics. Fingerprint biometric systems are either minutiae-based or pattern learning (image based. The minutiae-based algorithm depends upon the local discontinuities in the ridge flow pattern and are used when template size is important while image-based matching algorithm uses both the micro and macro feature of a fingerprint and is used if fast response is required. In the present paper an image-based fingerprint verification system is discussed. The proposed method uses a learning phase, which is not present in conventional image-based systems. The learning phase uses pseudo random sub-sampling, which reduces the number of comparisons needed in the matching stage. This system has been developed using LabVIEW (Laboratory Virtual Instrument Engineering Workbench toolbox version 6i. The availability of datalog files in LabVIEW makes it one of the most promising candidates for its usage as a database. Datalog files can access and manipulate data and complex data structures quickly and easily. It makes writing and reading much faster. After extensive experimentation involving a large number of samples and different learning sizes, high accuracy with learning image size of 100 100 and a threshold value of 700 (1000 being the perfect match has been achieved.

  19. Directional synthetic aperture flow imaging using a dual stage beamformer approach

    DEFF Research Database (Denmark)

    Li, Ye; Jensen, Jørgen Arendt

    2011-01-01

    . The new method has been studied using the Field II simulations and experimental flow rig measurements. A linear array transducer with 7 MHz center frequency is used, and 64 elements are active to transmit and receive signals. The data is processed in two stages. The first stage has a fixed focus point......A new method for directional synthetic aperture flow imaging using a dual stage beamformer approach is presented. The velocity estimation is angle independent and the amount of calculations is reduced compared to full synthetic aperture, but still maintains all the advantages at the same time....... In the second stage, focal points are considered as virtual sources and data is beamformed along the flow direction. Then the velocities are estimated by finding the spatial shift between two signals. In the experimental measurements the angle between the transmit beam and flow vessel was 70 and a laminar flow...

  20. Picture archiving and communications systems in radiation oncology (PACSRO): tools for a physician-based digital image review system

    International Nuclear Information System (INIS)

    McGee, K.P.; Das, I.J.; Fein, D.A.; Martin, E.E.; Schultheiss, T.E.; Hanks, G.E.

    1995-01-01

    Digital imaging is becoming more and more important in the diagnosis, staging, and treatment of patients in radiation oncology. In order to facilitate the most efficient interface of this technology to physicians and other users of this information, a medical image display system (MID) has been developed at the Fox Chase Cancer Center (FCCC). The system runs on 20 personal computers situated in physicians offices as well as a modified system located in the radiation oncology conference room. Access to CT, MRI, and EPID information is achieved through an Ethernet connection to the hospital picture archiving and communications system (PACS). Over a 1-year period a total of 503 patients and 3845 images have been stored on the system. Physician approval using the MID system (without conventional films) was performed on 106 patients. Of these, 22%, 16%, 11%, 10%, and 9% consisted of breast, prostate, pelvic, lung, and head and neck patients, respectively. Digital images sent from a variety of image sources to the MID system take up to 15 s to process and format while image access and display can take 2-5 s, dependent upon image size and speed of the host computer

  1. MR imaging of urinary bladder cancer for T-staging: a review and a pictorial essay of diffusion-weighted imaging.

    Science.gov (United States)

    Takeuchi, Mitsuru; Sasaki, Shigeru; Naiki, Taku; Kawai, Noriyasu; Kohri, Kenjiro; Hara, Masaki; Shibamoto, Yuta

    2013-12-01

    Treatment decisions for bladder cancer patients are mainly based on the depth of bladder wall invasion by the tumor. In this article, we review the conventional MRI and exhibit a recently emerged diffusion-weighted imaging (DWI) of urinary bladder cancer for T-staging. We discuss limitations of conventional MRI, scanning protocols of DWI, normal pelvic findings on DWI, determination of T-stage using DWI, and pitfalls of DWI. DWI provides high contrast between bladder cancer and background tissue because the cancer shows markedly high SI. DWI has high sensitivity for detecting the stalk seen in stage Ta or T1. An inflammatory change or fibrosis surrounding the tumor mimics the invasion of bladder cancer on T2-weighted imaging or enhanced MRI and could lead to over-staging, but DWI could differentiate them clearly because these benign changes do not show high SI on DWI. DWI is also useful for detecting ureteral, urethral, and prostatic extension by means of the urethra. DWI provides more accurate information on the extent of bladder cancer and contributes to determination of the treatment strategy. Copyright © 2013 Wiley Periodicals, Inc.

  2. Wide-bandwidth bilateral control using two-stage actuator system

    International Nuclear Information System (INIS)

    Kokuryu, Saori; Izutsu, Masaki; Kamamichi, Norihiro; Ishikawa, Jun

    2015-01-01

    This paper proposes a two-stage actuator system that consists of a coarse actuator driven by a ball screw with an AC motor (the first stage) and a fine actuator driven by a voice coil motor (the second stage). The proposed two-stage actuator system is applied to make a wide-bandwidth bilateral control system without needing expensive high-performance actuators. In the proposed system, the first stage has a wide moving range with a narrow control bandwidth, and the second stage has a narrow moving range with a wide control bandwidth. By consolidating these two inexpensive actuators with different control bandwidths in a complementary manner, a wide bandwidth bilateral control system can be constructed based on a mechanical impedance control. To show the validity of the proposed method, a prototype of the two-stage actuator system has been developed and basic performance was evaluated by experiment. The experimental results showed that a light mechanical impedance with a mass of 10 g and a damping coefficient of 2.5 N/(m/s) that is an important factor to establish good transparency in bilateral control has been successfully achieved and also showed that a better force and position responses between a master and slave is achieved by using the proposed two-stage actuator system compared with a narrow bandwidth case using a single ball screw system. (author)

  3. Health economics evaluation of magnetic resonance imaging for the staging of prostate cancer for Austria and Germany; Gesundheitsoekonomische Evaluation der Magnetresonanzbildgebung im Staging von Prostatakarzinomen fuer Oesterreich und Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, A. [Landesklinikum St. Poelten (Germany). Zentrales Inst. fuer Radiologie, Diagnostik und Interventionelle Therapie; Erlangen-Nuernberg Univ., Erlangen (Germany). Neurochirurgische Klinik; Bernt, R. [Hanusch Krankenhaus, Vienna (Austria). Zentralroentgeninstitut; Salomonowitz, E. [Landesklinikum St. Poelten (Germany). Zentrales Inst. fuer Radiologie, Diagnostik und Interventionelle Therapie; Plas, E. [Hanusch Krankenhaus, Vienna (Austria). Abt. fuer Urologie; Strunk, G. [Technische Univ. Dortmund (Germany). Wirtschaftwissenschaft und Oekonomische Bildung; Eberhardt, K. [Krankenhaus Schloss Werneck (Germany). MRT-Kompetenzzentrum

    2012-06-15

    Purpose: The aim of this study was the health economics analysis of MR imaging in the preoperative staging of patients with prostate carcinoma (PCa). Materials and Methods: The health economics analysis consisted of the following steps: modeling, determination of probabilities and parameters based on a detailed literature search, evaluation using the averages of the parameters, and sensitivity analyses of the results over the ranges of values. We performed a cost-utility analysis from health insurance's perspective for Austria and Germany. The population under investigation included patients with confirmed PCa. The alternative was a decision for therapy with or without staging using MR imaging. A localized PCa was treated by prostatectomy and locally advanced PCa by radiation/hormone therapy. The result parameters were quality adjusted life years (QALYs) and costs per patient. Results: The evaluation showed that MR imaging is useful regarding costs and utilities prior to radical prostatectomy which is expensive and may be associated with serious clinical consequences. The costs per patient were lower by Euro 2635 and the utilities were higher by 0.099 QALYs. The strategy without MR imaging for staging was dominated by the strategy using MR imaging for staging in the evaluation using the base values and in almost all sensitivity analyses. Conclusion: For the parameters used and almost all scenarios of the sensitivity analysis, our decision-analytic model revealed a higher cost-utility ratio for the strategy using MR imaging for the staging of PCa. (orig.)

  4. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V [Wayland, MA

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  5. A real-time dynamic imaging system for centrifugal microflow platforms

    International Nuclear Information System (INIS)

    Chang, Hsing-Cheng; Tsou, Chingfu; Lai, Chi-Chih; Wun, Guo-Hong

    2008-01-01

    Based on the operational concept of quasi-static state and optoelectronic measurement technology, this research develops a real-time dynamic imaging system for centrifugal microfluidic platforms. Unlike the conventional centrifugal inspection system, which can only be used for examination of the final steady stage in microflow analysis, the developed system with a multi-speed controller and object tracking design is fabricated with low cost to recognize dynamic microflow patterns for different kinds of compact disc-type centrifugal microstructures. The characteristics of rotational control efficiency and image acquisition quality are obtained from fluidic microvalve experiments that are achieved in measuring microflow dynamic responses and in visualizing transient microflow patterns. A man–machine interface was connected with a computer to perform the control and alignment adjustments to catch exact image data for following analysis. The rotation stability of the system has been evaluated, and the rotation speed up to 4500 rpm with vertical vibration less than ±0.2 mm is achieved measured at radial distance of 5 cm. The image acquisition is transferred via USB 2.0 at a speed of up to 30 images per second to the display and memory module

  6. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Directory of Open Access Journals (Sweden)

    Jin Woo Choi

    Full Text Available The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN. A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of

  7. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong; Kim, Hee Chan

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  8. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  9. Two-stage atlas subset selection in multi-atlas based image segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Tingting, E-mail: tingtingzhao@mednet.ucla.edu; Ruan, Dan, E-mail: druan@mednet.ucla.edu [The Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States)

    2015-06-15

    Purpose: Fast growing access to large databases and cloud stored data presents a unique opportunity for multi-atlas based image segmentation and also presents challenges in heterogeneous atlas quality and computation burden. This work aims to develop a novel two-stage method tailored to the special needs in the face of large atlas collection with varied quality, so that high-accuracy segmentation can be achieved with low computational cost. Methods: An atlas subset selection scheme is proposed to substitute a significant portion of the computationally expensive full-fledged registration in the conventional scheme with a low-cost alternative. More specifically, the authors introduce a two-stage atlas subset selection method. In the first stage, an augmented subset is obtained based on a low-cost registration configuration and a preliminary relevance metric; in the second stage, the subset is further narrowed down to a fusion set of desired size, based on full-fledged registration and a refined relevance metric. An inference model is developed to characterize the relationship between the preliminary and refined relevance metrics, and a proper augmented subset size is derived to ensure that the desired atlases survive the preliminary selection with high probability. Results: The performance of the proposed scheme has been assessed with cross validation based on two clinical datasets consisting of manually segmented prostate and brain magnetic resonance images, respectively. The proposed scheme demonstrates comparable end-to-end segmentation performance as the conventional single-stage selection method, but with significant computation reduction. Compared with the alternative computation reduction method, their scheme improves the mean and medium Dice similarity coefficient value from (0.74, 0.78) to (0.83, 0.85) and from (0.82, 0.84) to (0.95, 0.95) for prostate and corpus callosum segmentation, respectively, with statistical significance. Conclusions: The authors

  10. Two-stage atlas subset selection in multi-atlas based image segmentation.

    Science.gov (United States)

    Zhao, Tingting; Ruan, Dan

    2015-06-01

    Fast growing access to large databases and cloud stored data presents a unique opportunity for multi-atlas based image segmentation and also presents challenges in heterogeneous atlas quality and computation burden. This work aims to develop a novel two-stage method tailored to the special needs in the face of large atlas collection with varied quality, so that high-accuracy segmentation can be achieved with low computational cost. An atlas subset selection scheme is proposed to substitute a significant portion of the computationally expensive full-fledged registration in the conventional scheme with a low-cost alternative. More specifically, the authors introduce a two-stage atlas subset selection method. In the first stage, an augmented subset is obtained based on a low-cost registration configuration and a preliminary relevance metric; in the second stage, the subset is further narrowed down to a fusion set of desired size, based on full-fledged registration and a refined relevance metric. An inference model is developed to characterize the relationship between the preliminary and refined relevance metrics, and a proper augmented subset size is derived to ensure that the desired atlases survive the preliminary selection with high probability. The performance of the proposed scheme has been assessed with cross validation based on two clinical datasets consisting of manually segmented prostate and brain magnetic resonance images, respectively. The proposed scheme demonstrates comparable end-to-end segmentation performance as the conventional single-stage selection method, but with significant computation reduction. Compared with the alternative computation reduction method, their scheme improves the mean and medium Dice similarity coefficient value from (0.74, 0.78) to (0.83, 0.85) and from (0.82, 0.84) to (0.95, 0.95) for prostate and corpus callosum segmentation, respectively, with statistical significance. The authors have developed a novel two-stage atlas

  11. Two-stage atlas subset selection in multi-atlas based image segmentation

    International Nuclear Information System (INIS)

    Zhao, Tingting; Ruan, Dan

    2015-01-01

    Purpose: Fast growing access to large databases and cloud stored data presents a unique opportunity for multi-atlas based image segmentation and also presents challenges in heterogeneous atlas quality and computation burden. This work aims to develop a novel two-stage method tailored to the special needs in the face of large atlas collection with varied quality, so that high-accuracy segmentation can be achieved with low computational cost. Methods: An atlas subset selection scheme is proposed to substitute a significant portion of the computationally expensive full-fledged registration in the conventional scheme with a low-cost alternative. More specifically, the authors introduce a two-stage atlas subset selection method. In the first stage, an augmented subset is obtained based on a low-cost registration configuration and a preliminary relevance metric; in the second stage, the subset is further narrowed down to a fusion set of desired size, based on full-fledged registration and a refined relevance metric. An inference model is developed to characterize the relationship between the preliminary and refined relevance metrics, and a proper augmented subset size is derived to ensure that the desired atlases survive the preliminary selection with high probability. Results: The performance of the proposed scheme has been assessed with cross validation based on two clinical datasets consisting of manually segmented prostate and brain magnetic resonance images, respectively. The proposed scheme demonstrates comparable end-to-end segmentation performance as the conventional single-stage selection method, but with significant computation reduction. Compared with the alternative computation reduction method, their scheme improves the mean and medium Dice similarity coefficient value from (0.74, 0.78) to (0.83, 0.85) and from (0.82, 0.84) to (0.95, 0.95) for prostate and corpus callosum segmentation, respectively, with statistical significance. Conclusions: The authors

  12. Fiducial-Based Translational Localization Accuracy of Electromagnetic Tracking System and On-Board Kilovoltage Imaging System

    International Nuclear Information System (INIS)

    Santanam, Lakshmi; Malinowski, Kathleen; Hubenshmidt, James; Dimmer, Steve; Mayse, Martin L.; Bradley, Jeffrey; Chaudhari, Amir; Lechleiter, Kirsten; Goddu, Sree Krishna Murty; Esthappan, Jacqueline; Mutic, Sasa; Low, Daniel A.; Parikh, Parag

    2008-01-01

    Purpose: The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. Methods and Materials: The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. Results: The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. Conclusion: The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently

  13. Two-Stage Variable Sample-Rate Conversion System

    Science.gov (United States)

    Tkacenko, Andre

    2009-01-01

    A two-stage variable sample-rate conversion (SRC) system has been pro posed as part of a digital signal-processing system in a digital com munication radio receiver that utilizes a variety of data rates. The proposed system would be used as an interface between (1) an analog- todigital converter used in the front end of the receiver to sample an intermediatefrequency signal at a fixed input rate and (2) digita lly implemented tracking loops in subsequent stages that operate at v arious sample rates that are generally lower than the input sample r ate. This Two-Stage System would be capable of converting from an input sample rate to a desired lower output sample rate that could be var iable and not necessarily a rational fraction of the input rate.

  14. 4D atlas of the mouse embryo for precise morphological staging.

    Science.gov (United States)

    Wong, Michael D; van Eede, Matthijs C; Spring, Shoshana; Jevtic, Stefan; Boughner, Julia C; Lerch, Jason P; Henkelman, R Mark

    2015-10-15

    After more than a century of research, the mouse remains the gold-standard model system, for it recapitulates human development and disease and is quickly and highly tractable to genetic manipulations. Fundamental to the power and success of using a mouse model is the ability to stage embryonic mouse development accurately. Past staging systems were limited by the technologies of the day, such that only surface features, visible with a light microscope, could be recognized and used to define stages. With the advent of high-throughput 3D imaging tools that capture embryo morphology in microscopic detail, we now present the first 4D atlas staging system for mouse embryonic development using optical projection tomography and image registration methods. By tracking 3D trajectories of every anatomical point in the mouse embryo from E11.5 to E14.0, we established the first 4D atlas compiled from ex vivo 3D mouse embryo reference images. The resulting 4D atlas comprises 51 interpolated 3D images in this gestational range, resulting in a temporal resolution of 72 min. From this 4D atlas, any mouse embryo image can be subsequently compared and staged at the global, voxel and/or structural level. Assigning an embryonic stage to each point in anatomy allows for unprecedented quantitative analysis of developmental asynchrony among different anatomical structures in the same mouse embryo. This comprehensive developmental data set offers developmental biologists a new, powerful staging system that can identify and compare differences in developmental timing in wild-type embryos and shows promise for localizing deviations in mutant development. © 2015. Published by The Company of Biologists Ltd.

  15. Grating exchange system of independent mirror supported by floating rotary stage

    Science.gov (United States)

    Zhang, Jianhuan; Tao, Jin; Liu, Yan; Nan, Yan

    2015-10-01

    The performance of The Grating Exchange System can satisfy the Thirty Meter Telescope - TMT for astronomical observation WFOS index requirements and satisfy the requirement of accuracy in the grating exchange. It is used to install in the MOBIE and a key device of MOBIE. The Wide Field Optical Spectrograph (WFOS) is one of the three first-light observing capabilities selected by the TMT Science Advisory Committee. The Multi-Object Broadband Imaging Echellette (MOBIE) instrument design concept has been developed to address the WFOS requirements as described in the TMT Science-Based Requirements Document (SRD). The Grating Exchange System uses a new type of separate movement way of three grating devices and a mirror device. Three grating devices with a mirror are able to achieve independence movement. This kind of grating exchange system can effectively solve the problem that the volume of the grating change system is too large and that the installed space of MOBIE instruments is too limit. This system adopts the good stability, high precision of rotary stage - a kind of using air bearing (Air bearing is famous for its ultra-high precision, and can meet the optical accuracy requirement) and rotation positioning feedback gauge turntable to support grating device. And with a kind of device which can carry greater weight bracket fixed on the MOBIE instrument, with two sets of servo motor control rotary stage and the mirror device respectively. And we use the control program to realize the need of exercising of the grating device and the mirror device. Using the stress strain analysis software--SolidWorks for stress and strain analysis of this structure. And then checking the structure of the rationality and feasibility. And prove that this system can realize the positioning precision under different working conditions can meet the requirements of imaging optical grating diffraction efficiency and error by the calculation and optical performance analysis.

  16. Staged fluidized-bed combustion and filter system

    International Nuclear Information System (INIS)

    Mei, J.S.; Halow, J.S.

    1994-01-01

    A staged fluidized-bed combustion and filter system are described for substantially reducing the quantity of waste through the complete combustion into ash-type solids and gaseous products. The device has two fluidized-bed portions, the first primarily as a combustor/pyrolyzer bed, and the second as a combustor/filter bed. The two portions each have internal baffles to define stages so that material moving therein as fluidized beds travel in an extended route through those stages. Fluidization and movement is achieved by the introduction of gases into each stage through a directional nozzle. Gases produced in the combustor/pyrolyzer bed are permitted to travel into corresponding stages of the combustor/filter bed through screen filters that permit gas flow but inhibit solids flow. Any catalyst used in the combustor/filter bed is recycled. The two beds share a common wall to minimize total volume of the system. A slightly modified embodiment can be used for hot gas desulfurization and sorbent regeneration. Either side-by-side rectangular beds or concentric beds can be used. The system is particularly suited to the processing of radioactive and chemically hazardous waste. 10 figures

  17. Staging of intestinal- and diffuse-type gastric cancers with the OLGA and OLGIM staging systems.

    Science.gov (United States)

    Cho, S-J; Choi, I J; Kook, M-C; Nam, B-H; Kim, C G; Lee, J Y; Ryu, K W; Kim, Y-W

    2013-11-01

    Operative link on gastritis assessment (OLGA) and Operative link on gastric intestinal metaplasia assessment (OLGIM) staging systems have been proposed for gastric cancer (GC) risk estimation. To validate the OLGA and OLGIM staging systems in a region with high risk of GC. This retrospective study included 474 GC patients and age- and sex-matched health screening control persons in a cancer centre hospital. We classified gastritis patterns according to the OLGA and OLGIM systems using the histological database that a pathologist prospectively evaluated using the updated Sydney system. GC risk according to the OLGA and OLGIM stages was evaluated using logistic regression analysis. More GC patients had OLGA stages III-IV (46.2%) than controls (26.6%, P diffuse-type GCs (30.9%). OLGA stages III and IV were significantly associated with increased risk of GC [odds ratios (ORs), 2.09; P = 0.008 and 2.04; P = 0.014 respectively] in multivariate analysis. The association was more significant for intestinal-type (ORs, 4.76; P = 0.001 and 4.19; P = 0.002 respectively), but not diffuse-type GC. OLGIM stages from I to IV were significantly associated with increased risk of both intestinal-type (ORs, 3.64, 5.15, 7.89 and 13.20 respectively) and diffuse-type GC (ORs, 1.84, 2.59, 5.08 and 6.32 respectively) with a significantly increasing trend. As high OLGA and OLGIM stages are independent risk factors for gastric cancer, the staging systems may be useful for risk assessment in high-risk regions, especially for intestinal-type gastric cancer. © 2013 John Wiley & Sons Ltd.

  18. Development of computer-controlled ultrasonic image processing system for severe accidents research

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Kang, Kyung Ho; Kim, Jong Tai; Kim, Jong Whan; Cho, Young Ro; Ha, Kwang Soon; Park, Rae Jun; Kim, Sang Baik; Kim, Hee Dong; Sim, Chul Moo

    2000-07-01

    In order to verify in-vessel corium cooling mechanism, LAVA(Lower-plenum Arrested Vessel Attack) experiment is being performed as a first stage proof of principle test. The aims of this study are to find a gap formation between corium melt and reactor lower head vessel, to verify the principle of the gap formation and to analyze the effect of the gap formation on the thermal behavior of corium melt and the lower plenum. This report aims at developing a computer controlled image signal processing system which is able to improve visualization and to measure the gap distribution with 3-dimensional planar image using a time domain signal analysis method as a part of the ultrasonic pulse echo methods and a computerized position control system. An image signal processing system is developed by independently developing an ultrasonic image signal processing technique and a PC controlled position control system and then combining both systems

  19. Development of computer-controlled ultrasonic image processing system for severe accidents research

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kil Mo; Kang, Kyung Ho; Kim, Jong Tai; Kim, Jong Whan; Cho, Young Ro; Ha, Kwang Soon; Park, Rae Jun; Kim, Sang Baik; Kim, Hee Dong; Sim, Chul Moo

    2000-07-01

    In order to verify in-vessel corium cooling mechanism, LAVA(Lower-plenum Arrested Vessel Attack) experiment is being performed as a first stage proof of principle test. The aims of this study are to find a gap formation between corium melt and reactor lower head vessel, to verify the principle of the gap formation and to analyze the effect of the gap formation on the thermal behavior of corium melt and the lower plenum. This report aims at developing a computer controlled image signal processing system which is able to improve visualization and to measure the gap distribution with 3-dimensional planar image using a time domain signal analysis method as a part of the ultrasonic pulse echo methods and a computerized position control system. An image signal processing system is developed by independently developing an ultrasonic image signal processing technique and a PC controlled position control system and then combining both systems.

  20. Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging.

    Science.gov (United States)

    Mozaffarzadeh, Moein; Mahloojifar, Ali; Orooji, Mahdi; Adabi, Saba; Nasiriavanaki, Mohammadreza

    2018-01-01

    Photoacoustic imaging (PAI) is an emerging medical imaging modality capable of providing high spatial resolution of Ultrasound (US) imaging and high contrast of optical imaging. Delay-and-Sum (DAS) is the most common beamforming algorithm in PAI. However, using DAS beamformer leads to low resolution images and considerable contribution of off-axis signals. A new paradigm namely delay-multiply-and-sum (DMAS), which was originally used as a reconstruction algorithm in confocal microwave imaging, was introduced to overcome the challenges in DAS. DMAS was used in PAI systems and it was shown that this algorithm results in resolution improvement and sidelobe degrading. However, DMAS is still sensitive to high levels of noise, and resolution improvement is not satisfying. Here, we propose a novel algorithm based on DAS algebra inside DMAS formula expansion, double stage DMAS (DS-DMAS), which improves the image resolution and levels of sidelobe, and is much less sensitive to high level of noise compared to DMAS. The performance of DS-DMAS algorithm is evaluated numerically and experimentally. The resulted images are evaluated qualitatively and quantitatively using established quality metrics including signal-to-noise ratio (SNR), full-width-half-maximum (FWHM) and contrast ratio (CR). It is shown that DS-DMAS outperforms DAS and DMAS at the expense of higher computational load. DS-DMAS reduces the lateral valley for about 15 dB and improves the SNR and FWHM better than 13% and 30%, respectively. Moreover, the levels of sidelobe are reduced for about 10 dB in comparison with those in DMAS.

  1. Planning pesticides usage for herbal and animal pests based on intelligent classification system with image processing and neural networks

    Directory of Open Access Journals (Sweden)

    Dimililer Kamil

    2018-01-01

    Full Text Available Pests are divided into two as herbal and animal pests in agriculture, and detection and use of minimum pesticides are quite challenging task. Last three decades, researchers have been improving their studies on these manners. Therefore, effective, efficient, and as well as intelligent systems are designed and modelled. In this paper, an intelligent classification system is designed for detecting pests as herbal or animal to use of proper pesticides accordingly. The designed system suggests two main stages. Firstly, images are processed using different image processing techniques that images have specific distinguishing geometric patterns. The second stage is neural network phase for classification. A backpropagation neural network is used for training and testing with processed images. System is tested, and experiment results show efficiency and effective classification rate. Autonomy and time efficiency within the pesticide usage are also discussed.

  2. Comparison of renal dynamic imaging and modified MDRD equation in determining the stage of chronic kidney disease patients

    International Nuclear Information System (INIS)

    Xie Peng; Liu Xiaomei; Huang Jianmin; Zhang Fang; Pan Liping; Wu Weijie; Gao Jianqing

    2013-01-01

    Objective: To compare the accuracy of 99 Tc m -diethylene triamine pentaacetic acid ( 99 Tc m -DTPA) renal dynamic imaging and modified modification of diet in renal disease trail (MDRD) equation in determining the stage of the chronic kidney disease (CKD) patients in clinical practice. Methods: A total of 169 patients were enrolled whose glomerular filtration rate (GFR) were determined simultaneously by 3 methods: dual plasma sample clearance method, renal dynamic imaging and modified MDRD equation. The dual plasma sample clearance method was employed as the reference method. The accuracy of the other methods in determining the stage of CKD patients was compared and the comparison was repeated based on the different stages. Results: The accuracy of renal dynamic imaging and modified MDRD equation was 56.80% and 68.64%, respectively (P=0.019<0.05). And only in the stage of uremia, the difference of the above-mentioned two method reached statistical significance (P=0.012<0.05), while in other stages they showed similar performance (P=0.180, 0.424, 0.629 and 0.754, all P>0.05). Conclusion: Modified MDRD equation showed better performance than renal dynamic imaging or as good as the second one in determining the stage of CKD patients and the former one should be the first choice in clinical practice because of its simplicity and economy. (authors)

  3. The role of medical imaging in staging and followup of primary lung cancers

    International Nuclear Information System (INIS)

    Bragg, D.G.

    1986-01-01

    There has been a significant improvement in the rate of resectability of lung cancers, a situation that has resulted from improved preoperative staging. A large measure of this improvement has resulted from the application of CT and more recently, magnetic resonance imaging in this pre-surgical staging process. The application and evaluation of these imaging procedures has resulted in significant controversy. The size criteria of lymph nodes chosen in defining the abnormal mediastinal lymph node is responsible for part of the controversy. If the lymph node size is set below 2.0 cm, a higher false-positive rate must be accepted. In addition, chest wall extension is often inaccurately assessed with CT as is mediastinal invasion. The status of CT and MRI in staging the patient with lung cancer prior to surgery will be discussed in detail. It should be remembered that the ultimate goal of radiographic procedures in this staging process should be in determining which patients need mediastinoscopy prior to surgery and not in attempting to exclude patients from surgery. The appropriate formula for the application of CT and MRI will also be included. Finally, a recommendation for the post-treatment followup of the patient with lung cancer will also be presented. (Author)

  4. FDG-PET/CT imaging for staging and target volume delineation in conformal radiotherapy of anal carcinoma

    International Nuclear Information System (INIS)

    Krengli, Marco; Inglese, Eugenio; Milia, Maria E; Turri, Lucia; Mones, Eleonora; Bassi, Maria C; Cannillo, Barbara; Deantonio, Letizia; Sacchetti, Gianmauro; Brambilla, Marco

    2010-01-01

    FDG-PET/CT imaging has an emerging role in staging and treatment planning of various tumor locations and a number of literature studies show that also the carcinoma of the anal canal may benefit from this diagnostic approach. We analyzed the potential impact of FDG-PET/CT in stage definition and target volume delineation of patients affected by carcinoma of the anal canal and candidates for curative radiotherapy. Twenty seven patients with biopsy proven anal carcinoma were enrolled. Pathology was squamous cell carcinoma in 20 cases, cloacogenic carcinoma in 3, adenocarcinoma in 2, and basal cell carcinoma in 2. Simulation was performed by PET/CT imaging with patient in treatment position. Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) were drawn on CT and on PET/CT fused images. PET-GTV and PET-CTV were respectively compared to CT-GTV and CT-CTV by Wilcoxon rank test for paired data. PET/CT fused images led to change the stage in 5/27 cases (18.5%): 3 cases from N0 to N2 and 2 from M0 to M1 leading to change the treatment intent from curative to palliative in a case. Based on PET/CT imaging, GTV and CTV contours changed in 15/27 (55.6%) and in 10/27 cases (37.0%) respectively. PET-GTV and PET-CTV resulted significantly smaller than CT-GTV (p = 1.2 × 10 -4 ) and CT-CTV (p = 2.9 × 10 -4 ). PET/CT-GTV and PET/CT-CTV, that were used for clinical purposes, were significantly greater than CT-GTV (p = 6 × 10 -5 ) and CT-CTV (p = 6 × 10 -5 ). FDG-PET/CT has a potential relevant impact in staging and target volume delineation of the carcinoma of the anal canal. Clinical stage variation occurred in 18.5% of cases with change of treatment intent in 3.7%. The GTV and the CTV changed in shape and in size based on PET/CT imaging

  5. Association between perception of body image and stages of behavioral changes among physical education university students

    Directory of Open Access Journals (Sweden)

    Elisa Pinheiro Ferrari

    2012-08-01

    The objective of this study was to evaluate the association between the percep­tion of body image and the stages of behavioral changes related to physical activity among Physical Education Students. Two hundred thirty six students were included. We measured the perception of body image (silhouettes scale, the stages of changes in behavior related to physical activity using a questionnaire developed by Marcus et al., and socio-demographic variables (gender, age, parental education, marital status, course, employment situation, housing, period of study and income. We used descriptive analysis, chi-square test, Fischer’s exact test, crude and adjusted multinomial regression to estimate the odds ratio (OR and 95% confidence intervals (95% CI. The prevalence of physically inactive behavior was 18.2% for males and 23.9% for females. Dissatisfaction with body image was associated with the stages of behavioral changes in females, with women with physically inactive behavior having greater odds of experiencing dissatisfaction with their body image, both for underweight (OR: 9.69; 95% CI: 1.05-89.30 and overweight (OR: 5.49; 95% CI: 1.07-28.11 when compared with women who were satisfied with their body image. We suggest the development of in­terventions aimed at the adoption of regular physical activity in order to promote greater satisfaction with body image.

  6. Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Chan, Sheng-Chieh; Yen, Tzu-Chen; Liu, Feng-Yuan; Chang, Joseph Tung-Chieh; Fan, Kang-Hsing; Liao, Chun-Ta; Ko, Sheung-Fat; Chin, Shu-Chyn; Hsu, Cheng-Lung

    2009-01-01

    We prospectively compared PET/CT and conventional imaging for initial staging of nasopharyngeal carcinoma (NPC). A total of 111 patients with histologically proven NPC were investigated with PET/CT and conventional imaging (head-and-neck MRI, chest X-ray, abdominal ultrasound, and bone scan) before treatment. The respective findings were reviewed independently and then compared with each other. With regard to T staging, PET/CT showed a discrepancy with head-and-neck MRI in 36 (32.4%) of the study subjects. With regard to N staging, PET/CT showed a discrepancy with head-and-neck MRI in 15 (13.5%) patients. Among the discordant cases, MRI was superior in demonstrating tumor involvement in the parapharyngeal space, skull base, intracranial area, sphenoid sinus, and retropharyngeal nodes while PET/CT was superior in demonstrating neck nodal metastasis. PET/CT disclosed 13 of 16 patients with distant malignancy compared with four patients disclosed by conventional imaging work-up. The false-positive rate of PET/CT was 18.8%. PET/CT correctly modified M staging in eight patients (7.2%) and disclosed a second primary lung malignancy in one patient (0.9%). In NPC patients, MRI appears to be superior to PET/CT for the assessment of locoregional invasion and retropharyngeal nodal metastasis. PET/CT is more accurate than MRI for determining cervical nodal metastasis and should be the better reference for the neck status. PET/CT has an acceptable diagnostic yield and a low false-positive rate for the detection of distant malignancy and can replace conventional work-up to this aim. PET/CT and head-and-neck MRI are suggested for the initial staging of NPC patients. (orig.)

  7. Use of multimodality imaging and artificial intelligence for diagnosis and prognosis of early stages of Alzheimer's disease.

    Science.gov (United States)

    Liu, Xiaonan; Chen, Kewei; Wu, Teresa; Weidman, David; Lure, Fleming; Li, Jing

    2018-04-01

    Alzheimer's disease (AD) is a major neurodegenerative disease and the most common cause of dementia. Currently, no treatment exists to slow down or stop the progression of AD. There is converging belief that disease-modifying treatments should focus on early stages of the disease, that is, the mild cognitive impairment (MCI) and preclinical stages. Making a diagnosis of AD and offering a prognosis (likelihood of converting to AD) at these early stages are challenging tasks but possible with the help of multimodality imaging, such as magnetic resonance imaging (MRI), fluorodeoxyglucose (FDG)-positron emission topography (PET), amyloid-PET, and recently introduced tau-PET, which provides different but complementary information. This article is a focused review of existing research in the recent decade that used statistical machine learning and artificial intelligence methods to perform quantitative analysis of multimodality image data for diagnosis and prognosis of AD at the MCI or preclinical stages. We review the existing work in 3 subareas: diagnosis, prognosis, and methods for handling modality-wise missing data-a commonly encountered problem when using multimodality imaging for prediction or classification. Factors contributing to missing data include lack of imaging equipment, cost, difficulty of obtaining patient consent, and patient drop-off (in longitudinal studies). Finally, we summarize our major findings and provide some recommendations for potential future research directions. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Automated Image Acquisition System for the Verification of Copper-Brass Seal Images

    International Nuclear Information System (INIS)

    Stringa, E.; Bergonzi, C.; Littmann, F.; ); Marszalek, Y.; Tempesta, S.; )

    2015-01-01

    This paper describes a system for the verification of copper-brass seals realized by JRC according to DG ENER requirements. DG ENER processes about 20,000 metal seals per year. The verification of metal seals consists in visually checking the identity of a removed seal. The identity of a copper-brass seal is defined by a random stain pattern realized by the seal producer together with random scratches engraved when the seals are initialized ('seal production'). In order to verify that the seal returned from the field is the expected one its pattern is compared with an image taken during seal production. Formerly, seal initialization and verification were very heavy tasks as seal pictures were acquired with a camera one by one both in the initialization and verification stages. During the initialization the Nuclear Safeguards technicians had to place one by one new seals under a camera and acquire the related reference images. During the verification, the technician had to take used seals and place them one by one under a camera to take new pictures. The new images were presented to the technicians without any preprocessing and the technicians had to recognize the seal. The new station described in this paper has an automated image acquisition system allowing to easily process seals in batches of 100 seals. To simplify the verification, a software automatically centres and rotates the newly acquired seal image in order to perfectly overlap with the reference image acquired during the production phase. The new system significantly speeds up seal production and helps particularly with the demanding task of seal verification. As a large part of the seals is dealt with by a joint Euratom-IAEA team, the IAEA directly profits from this development. The new tool has been in routine use since mid 2013. (author)

  9. An image-based automatic recognition method for the flowering stage of maize

    Science.gov (United States)

    Yu, Zhenghong; Zhou, Huabing; Li, Cuina

    2018-03-01

    In this paper, we proposed an image-based approach for automatic recognizing the flowering stage of maize. A modified HOG/SVM detection framework is first adopted to detect the ears of maize. Then, we use low-rank matrix recovery technology to precisely extract the ears at pixel level. At last, a new feature called color gradient histogram, as an indicator, is proposed to determine the flowering stage. Comparing experiment has been carried out to testify the validity of our method and the results indicate that our method can meet the demand for practical observation.

  10. [Helicobacter pylori gastritis: assessment of OLGA and OLGIM staging systems].

    Science.gov (United States)

    Ben Slama, Sana; Ben Ghachem, Dorra; Dhaoui, Amen; Jomni, Mohamed Taieb; Dougui, Mohamed Hédi; Bellil, Khadija

    2016-01-01

    Helicobacter pylori (H pylori) gastritis presents a risk of cancer related to atrophy and intestinal metaplasia. Two recent classifications OLGA (Operative Link on Gastritis Assessment) and OLGIM (Operative Link on Gastritic Intestinal Metaplasia assessment) have been proposed to identify high-risk forms (stages III and IV). The aim of this study is to evaluate the OLGA and OLGIM staging systems in H pylori gastritis. A descriptive study of 100 cases of chronic H pylori gastritis was performed. The revaluation of Sydney System parameters of atrophy and intestinal metaplasia, of gastric antrum and corpus, allowed identifying respectively the stages of OLGA and OLGIM systems. The progressive risk of our H pylori gastritis was 6% according to OLGA staging and 7% according to OLGIM staging. Significant correlation was revealed between age and OLGA staging. High-risk gastritis according to OLGIM staging was significantly associated with moderate to severe atrophy. High-risk forms according to OLGA staging were associated in 80% of the cases to intestinal metaplasia. OLGA and OLGIM systems showed a highly significant positive correlation between them with a mismatch at 5% for H pylori gastritis. The OLGA and OLGIM staging systems in addition to Sydney System, allow selection of high risk forms of chronic gastritis requiring accurate observation.

  11. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  12. A simplified staging system based on the radiological findings in different stages of ochronotic spondyloarthropathy

    International Nuclear Information System (INIS)

    Jebaraj, Isaac; Chacko, Binita Riya; Chiramel, George Koshy; Matthai, Thomas; Parameswaran, Apurve

    2013-01-01

    This study describes a group of 26 patients with ochronotic spondyloarthropathy who were on regular treatment and follow-up at a tertiary level hospital and proposes a simplified staging system for ochronotic spondyloarthropathy based on radiographic findings seen in the thoracolumbar spine. This proposed classification makes it easy to identify the stage of the disease and start the appropriate management at an early stage. Four progressive stages are described: an inflammatory stage (stage 1), the stage of early discal calcification (stage 2), the stage of fibrous ankylosis (stage 3), and the stage of bony ankylosis (stage 4). To our knowledge, this is the largest reported series of radiological description of spinal ochronosis, and emphasizes the contribution of the spine radiograph in the diagnosis and staging of the disease

  13. A simplified staging system based on the radiological findings in different stages of ochronotic spondyloarthropathy

    Directory of Open Access Journals (Sweden)

    Isaac Jebaraj

    2013-01-01

    Full Text Available This study describes a group of 26 patients with ochronotic spondyloarthropathy who were on regular treatment and follow-up at a tertiary level hospital and proposes a simplified staging system for ochronotic spondyloarthropathy based on radiographic findings seen in the thoracolumbar spine. This proposed classification makes it easy to identify the stage of the disease and start the appropriate management at an early stage. Four progressive stages are described: an inflammatory stage (stage 1, the stage of early discal calcification (stage 2, the stage of fibrous ankylosis (stage 3, and the stage of bony ankylosis (stage 4. To our knowledge, this is the largest reported series of radiological description of spinal ochronosis, and emphasizes the contribution of the spine radiograph in the diagnosis and staging of the disease.

  14. Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer

    Science.gov (United States)

    Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.

    2018-02-01

    Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.

  15. Hypo Activity of Cholinergic System in Patients with Early Stage of Alzheimer's Disease

    International Nuclear Information System (INIS)

    Davidescu, L.; Codorean, I.; Matei, C.; Barret, O.; Mazere, J.; Guyot, M.; Rimbu, A.; Allard, M.

    2006-01-01

    Full text: Objective A cholinergic dysfunction was documented in advanced stages of Alzheimer's disease. In order to specify the cholinergic involvement in early stages, we performed a presynaptic imaging study of the cholinergic system using a vesicular Acetylcholine transporter ligand labelled with iodine 123 ( 123 I-IBVM - Iodobenzovesamicol) Materials And Methods Eight patients (5 women and 3 men, 74-89 years, MMS>23) and 8 controls (6 women and 2 men, 72-80 years, MMS>30) have been evaluated using the neuropsychological tests; cerebral SPECT was performed 6 hours after intravenous injection of 218±19 MBq of 123 I - IBVM (30 min, 3 volume, 128x128) and the 3D MRI (T1 weighted images). Acquisition data were processed by filtered retroprojection (Butterworth 5.35) and analysed with SPM software. Each examination was co-registered with the MRI of the patient, normalised in the MNI template and smoothed (10mm). Results The analyse of the group (two sample T-test, p 123 I-IBVM has been detected in the patients group, compared to the control. Conclusions Our results indicate that cholinergic dysfunctions appear very early in the development of Alzheimer's disease and affect the cortical structures involved in the attention process. Some studies are in progress to analyze imaging data with cognitive impairments of each patient. (author)

  16. An image based information system - Architecture for correlating satellite and topological data bases

    Science.gov (United States)

    Bryant, N. A.; Zobrist, A. L.

    1978-01-01

    The paper describes the development of an image based information system and its use to process a Landsat thematic map showing land use or land cover in conjunction with a census tract polygon file to produce a tabulation of land use acreages per census tract. The system permits the efficient cross-tabulation of two or more geo-coded data sets, thereby setting the stage for the practical implementation of models of diffusion processes or cellular transformation. Characteristics of geographic information systems are considered, and functional requirements, such as data management, geocoding, image data management, and data analysis are discussed. The system is described, and the potentialities of its use are examined.

  17. Gadolinium-enhanced dynamic magnetic resonance imaging with endorectal coil for local staging of rectal cancer

    International Nuclear Information System (INIS)

    Tamakawa, Mitsuharu; Kawaai, Yuriko; Shirase, Ryuji

    2010-01-01

    The aim of this study was to evaluate the accuracy of dynamic gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) with endorectal coil for assessing tumor invasion based on simple classification criteria. A total of 58 patients with operable primary rectal cancer underwent preoperative MRI. An enhancement pattern in Gd-enhanced dynamic MRI with regard to tumor penetration was clarified. Retrospectively, two observers independently scored T2-weighted MRI and T2-weighted MRI combined with Gd-enhanced dynamic MRI for tumor penetration using the following criteria: With Gd-enhanced dynamic MRI, T1 tumors showed an early enhanced line around the tumor as rim enhancement; T2 tumors appeared as black lines or double layers, as the muscularis propria kept its integrity; T3 tumors showed partial discontinuity of the muscularis propria as a dotted line and a perforated area as an interrupted line. A confidence level scoring system was used, and receiver operating characteristic curves were generated. There were no significant differences at the T1 stage. There were significant differences for observer 1 (P=0.001 for observer 1) at the T2 stage. There were significant differences for both observers (P=0.001 for observer 1 and P=0.005 for observer 2) at the T3 stage. Our criteria for Gd-enhanced dynamic MRI were effective for T3 stage tumors. (author)

  18. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  19. The Application of Use Case Modeling in Designing Medical Imaging Information Systems

    International Nuclear Information System (INIS)

    Safdari, Reza; Farzi, Jebraeil; Ghazisaeidi, Marjan; Mirzaee, Mahboobeh; Goodini, Azadeh

    2013-01-01

    Introduction. The essay at hand is aimed at examining the application of use case modeling in analyzing and designing information systems to support Medical Imaging services. Methods. The application of use case modeling in analyzing and designing health information systems was examined using electronic databases (Pubmed, Google scholar) resources and the characteristics of the modeling system and its effect on the development and design of the health information systems were analyzed. Results. Analyzing the subject indicated that Provident modeling of health information systems should provide for quick access to many health data resources in a way that patients' data can be used in order to expand distant services and comprehensive Medical Imaging advices. Also these experiences show that progress in the infrastructure development stages through gradual and repeated evolution process of user requirements is stronger and this can lead to a decline in the cycle of requirements engineering process in the design of Medical Imaging information systems. Conclusion. Use case modeling approach can be effective in directing the problems of health and Medical Imaging information systems towards understanding, focusing on the start and analysis, better planning, repetition, and control

  20. Effect of Filmless Imaging on Utilization of Radiologic Services with a Two-stage, Hospital-Wide Implementation of a Picture Archiving and Communication System: Initial Experience of a Fee-for-Service Model

    Directory of Open Access Journals (Sweden)

    Yu-Ting Kuo

    2003-02-01

    Full Text Available A medium-sized general hospital using a fee-for-service model implemented a hospital-wide picture archiving and communication system (PACS in two stages. This study evaluated the reporting time with filmless operation and the effect of filmless imaging on referring physicians' use of the radiologic service before and after completion of the second stage of PACS implementation. The relationship between the total number of hospital patients and the number of radiologic department patients was also evaluated. All sample images were retrieved from the PACS. All corresponding reports except for one for a computerized tomography study were available. The median reporting time for different studies performed during working hours was less than 2 hours. There was a significantly positive and linear relationship (p < 0.01 between the total number of hospital patients and the number of radiologic department patients after hospital-wide implementation of PACS. We conclude that the fee-for-service model had no negative impact on referring physicians' use of radiologic services in a filmless hospital.

  1. Evaluation of 99Tcm-trodat-1 SPECT/CT imaging in the diagnosis of parkinson's disease in early stage

    International Nuclear Information System (INIS)

    Liu Xiaohua; Tai Jian; Zhang Fuhai; Xiao Qian; Jia Qiang; Dong Feng

    2004-01-01

    Parkinson's disease is a progressive neurodegenerative disorder characterized by a selective loss of dopamine in the striatum with age. At present, the diagnosis of Parkinson's disease is mainly remained in clinical standard. According to the clinical symptoms and the response to DOPA treatment, it is not difficult to diagnose typical PD. But it is difficult to diagnose early stage PD, which lacks the typical clinical symptoms and signs. A 99Tcm -labeled tropane derivative that binds to dopamine transporter with high selectivity is [2- [ [2- [ [ [3- (4-chlorophenyl)- 8-methyl- 8-azabicyclo [3,2,1 ] oct-2-yl]methyl] (2-mercaptoethyl)amino] eth yl]amino]ethanethiolato(3-)-N2,N2',S2,S2'] oxo-[1R-(exo-exo)] (TRODAT-1). Objective: The purpose of this study is to evaluate the clinical application of 99Tcm-TRODAT-1 SPECT/CT imaging in the diagnosis of Parkinson's disease (PD) in early stage. Methods: Twenty-four patients with early-stage idiopathic Parkinson's disease were recruited. For all patients, the severity was assessed by the Hoehnand Yahrscale. Twenty-four early stage PD patients (15 Hoehn Yahr stage I and 9 Hoehn Yahr stage II), eight advanced PD patients and ten healthy volunteers (five men, five women) were studied by 99Tcm-TRODAT-1 SPECT/CT imaging. 99Tcm-TRODAT-1 was prepared from a lyophilized kit. Brain SPECT imaging was performed 2 hours after injection, using GE Discovery VH equipped with FanBeam collimators. Data were obtained using energy window of 20% centered on 140 KEV for 99Tcm. The brain SPECT data were acquired after Hawkeye CT acquisition. Regions of interest were delineated over the striata and the cerebella, and the ratios of striatum-to-cerebellum (ST/CB) were calculated. Specific uptake in the striatum and its subregions, including the putamen and caudate nucleus, was calculated and compared with that of the other side as well as that of healthy volunteers. Results: Dopamine transporter (DAT) imaging of the 10 healthy volunteers showed

  2. A multi-stage noise adaptive switching filter for extremely corrupted images

    Science.gov (United States)

    Dinh, Hai; Adhami, Reza; Wang, Yi

    2015-07-01

    A multi-stage noise adaptive switching filter (MSNASF) is proposed for the restoration of images extremely corrupted by impulse and impulse-like noise. The filter consists of two steps: noise detection and noise removal. The proposed extrema-based noise detection scheme utilizes the false contouring effect to get better over detection rate at low noise density. It is adaptive and will detect not only impulse but also impulse-like noise. In the noise removal step, a novel multi-stage filtering scheme is proposed. It replaces corrupted pixel with the nearest uncorrupted median to preserve details. When compared with other methods, MSNASF provides better peak signal to noise ratio (PSNR) and structure similarity index (SSIM). A subjective evaluation carried out online also demonstrates that MSNASF yields higher fidelity.

  3. Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non–small-cell lung cancer

    OpenAIRE

    Tan, Zhibo; Liu, Chuanyao; Zhou, Ying; Shen, Weixi

    2017-01-01

    Abstract In this study, we compared the registration effectiveness of 4D cone-beam computed tomography (CBCT) and 3D-CBCT for image-guided radiotherapy in 20 Stage IA non–small-cell lung cancer (NSCLC) patients. Patients underwent 4D-CBCT and 3D-CBCT immediately before radiotherapy, and the X-ray Volume Imaging software system was used for image registration. We performed automatic bone registration and soft tissue registration between 4D-CBCT or 3D-CBCT and 4D-CT images; the regions of inter...

  4. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head.

    Science.gov (United States)

    Meier, Reinhard; Kraus, Tobias M; Schaeffeler, Christoph; Torka, Sebastian; Schlitter, Anna Melissa; Specht, Katja; Haller, Bernhard; Waldt, Simone; Rechl, Hans; Rummeny, Ernst J; Woertler, Klaus

    2014-09-01

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53% women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51%) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49%) cases were classified as ARCO stage 2. However, in all 37/37 (100%) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. BME on MRI in AVN of femoral head indicates a subchondral fracture. BME in AVN of the femoral head represents ARCO stage 3/4 disease. CT identifies subchondral fractures and femoral head collapse better than MR imaging. This knowledge helps to avoid understaging and to trigger adequate treatment.

  5. Image reconstruction of dynamic infrared single-pixel imaging system

    Science.gov (United States)

    Tong, Qi; Jiang, Yilin; Wang, Haiyan; Guo, Limin

    2018-03-01

    Single-pixel imaging technique has recently received much attention. Most of the current single-pixel imaging is aimed at relatively static targets or the imaging system is fixed, which is limited by the number of measurements received through the single detector. In this paper, we proposed a novel dynamic compressive imaging method to solve the imaging problem, where exists imaging system motion behavior, for the infrared (IR) rosette scanning system. The relationship between adjacent target images and scene is analyzed under different system movement scenarios. These relationships are used to build dynamic compressive imaging models. Simulation results demonstrate that the proposed method can improve the reconstruction quality of IR image and enhance the contrast between the target and the background in the presence of system movement.

  6. Attainability and minimum energy of multiple-stage cascade membrane Systems

    KAUST Repository

    Alshehri, Ali

    2015-08-12

    Process design and simulation of multi-stage membrane systems have been widely studied in many gas separation systems. However, general guidelines have not been developed yet for the attainability and the minimum energy consumption of a multi-stage membrane system. Such information is important for conceptual process design and thus it is the topic of this work. Using a well-mixed membrane model, it was determined that the attainability curve of multi-stage systems is defined by the pressure ratio and membrane selectivity. Using the constant recycle ratio scheme, the recycle ratio can shift the attainability behavior between single-stage and multi-stage membrane systems. When the recycle ratio is zero, all of the multi-stage membrane processes will decay to a single-stage membrane process. When the recycle ratio approaches infinity, the required selectivity and pressure ratio reach their absolute minimum values, which have a simple relationship with that of a single-stage membrane process, as follows: View the MathML sourceSn=S1, View the MathML sourceγn=γ1, where n is the number of stages. The minimum energy consumption of a multi-stage membrane process is primarily determined by the membrane selectivity and recycle ratio. A low recycle ratio can significantly reduce the required membrane selectivity without substantial energy penalty. The energy envelope curve can provide a guideline from an energy perspective to determine the minimum required membrane selectivity in membrane process designs to compete with conventional separation processes, such as distillation.

  7. A Two-Stage Framework for 3D Face Reconstruction from RGBD Images.

    Science.gov (United States)

    Wang, Kangkan; Wang, Xianwang; Pan, Zhigeng; Liu, Kai

    2014-08-01

    This paper proposes a new approach for 3D face reconstruction with RGBD images from an inexpensive commodity sensor. The challenges we face are: 1) substantial random noise and corruption are present in low-resolution depth maps; and 2) there is high degree of variability in pose and face expression. We develop a novel two-stage algorithm that effectively maps low-quality depth maps to realistic face models. Each stage is targeted toward a certain type of noise. The first stage extracts sparse errors from depth patches through the data-driven local sparse coding, while the second stage smooths noise on the boundaries between patches and reconstructs the global shape by combining local shapes using our template-based surface refinement. Our approach does not require any markers or user interaction. We perform quantitative and qualitative evaluations on both synthetic and real test sets. Experimental results show that the proposed approach is able to produce high-resolution 3D face models with high accuracy, even if inputs are of low quality, and have large variations in viewpoint and face expression.

  8. CT and MRI findings of Creutzfeldt-Jakob disease in the early stage. The usefulness of diffusion-weighted images

    International Nuclear Information System (INIS)

    Ukisu, Ryutaro; Kushihashi, Tamio; Gokan, Takehiko

    2001-01-01

    To detect subtle CT and MRI features of Creutzfeldt-Jacob disease (CJD) in the early stage is important to prevent a human-to-human transmission. This study included 10 patients of CJD who underwent CT and/or MRI in its early stage. CT, T1- and T2-weighted MRI, DWI, and FLAIR images were obtained in 10, 6, 4, and 2 patients respectively. On DWI, abnormal hyperintensities were observed in both cerebral cortex, and in basal ganglia in all patients. On FLAIR images, abnormal hyperintensies were observed in one patient. Detection of abnormal intensities may be possible in the early stage of CJD using MRI, particularly with DWI. (author)

  9. CT and MRI findings of Creutzfeldt-Jakob disease in the early stage. The usefulness of diffusion-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Ukisu, Ryutaro; Kushihashi, Tamio; Gokan, Takehiko [Showa Univ., Tokyo (Japan). School of Medicine] [and others

    2001-02-01

    To detect subtle CT and MRI features of Creutzfeldt-Jacob disease (CJD) in the early stage is important to prevent a human-to-human transmission. This study included 10 patients of CJD who underwent CT and/or MRI in its early stage. CT, T1- and T2-weighted MRI, DWI, and FLAIR images were obtained in 10, 6, 4, and 2 patients respectively. On DWI, abnormal hyperintensities were observed in both cerebral cortex, and in basal ganglia in all patients. On FLAIR images, abnormal hyperintensies were observed in one patient. Detection of abnormal intensities may be possible in the early stage of CJD using MRI, particularly with DWI. (author)

  10. Revised National Pressure Ulcer Advisory Panel Pressure Injury Staging System: Revised Pressure Injury Staging System.

    Science.gov (United States)

    Edsberg, Laura E; Black, Joyce M; Goldberg, Margaret; McNichol, Laurie; Moore, Lynn; Sieggreen, Mary

    Our understanding of pressure injury etiology and development has grown in recent years through research, clinical expertise, and global interdisciplinary expert collaboration. Therefore, the National Pressure Ulcer Advisory Panel (NPUAP) has revised the definition and stages of pressure injury. The revision was undertaken to incorporate the current understanding of the etiology of pressure injuries, as well as to clarify the anatomical features present or absent in each stage of injury. An NPUAP-appointed Task Force reviewed the literature and created drafts of definitions, which were then reviewed by stakeholders and the public, including clinicians, educators, and researchers around the world. Using a consensus-building methodology, these revised definitions were the focus of a multidisciplinary consensus conference held in April 2016. As a result of stakeholder and public input, along with the consensus conference, important changes were made and incorporated into the new staging definitions. The revised staging system uses the term injury instead of ulcer and denotes stages using Arabic numerals rather than Roman numerals. The revised definition of a pressure injury now describes the injuries as usually occurring over a bony prominence or under a medical or other device. The revised definition of a Stage 2 pressure injury seeks to clarify the difference between moisture-associated skin damage and injury caused by pressure and/or shear. The term suspected has been removed from the Deep Tissue Pressure Injury diagnostic label. Each definition now describes the extent of tissue loss present and the anatomical features that may or may not be present in the stage of injury. These important revisions reflect the methodical and collaborative approach used to examine the available evidence and incorporate current interdisciplinary clinical expertise into better defining the important phenomenon of pressure injury etiology and development.

  11. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  12. A translating stage system for µ-PIV measurements surrounding the tip of a migrating semi-infinite bubble.

    Science.gov (United States)

    Smith, B J; Yamaguchi, E; Gaver, D P

    2010-01-01

    We have designed, fabricated and evaluated a novel translating stage system (TSS) that augments a conventional micro particle image velocimetry (µ-PIV) system. The TSS has been used to enhance the ability to measure flow fields surrounding the tip of a migrating semi-infinite bubble in a glass capillary tube under both steady and pulsatile reopening conditions. With conventional µ-PIV systems, observations near the bubble tip are challenging because the forward progress of the bubble rapidly sweeps the air-liquid interface across the microscopic field of view. The translating stage mechanically cancels the mean bubble tip velocity, keeping the interface within the microscope field of view and providing a tenfold increase in data collection efficiency compared to fixed-stage techniques. This dramatic improvement allows nearly continuous observation of the flow field over long propagation distances. A large (136-frame) ensemble-averaged velocity field recorded with the TSS near the tip of a steadily migrating bubble is shown to compare well with fixed-stage results under identical flow conditions. Use of the TSS allows the ensemble-averaged measurement of pulsatile bubble propagation flow fields, which would be practically impossible using conventional fixed-stage techniques. We demonstrate our ability to analyze these time-dependent two-phase flows using the ensemble-averaged flow field at four points in the oscillatory cycle.

  13. Thresholding: A Pixel-Level Image Processing Methodology Preprocessing Technique for an OCR System for the Brahmi Script

    Directory of Open Access Journals (Sweden)

    H. K. Anasuya Devi

    2006-12-01

    Full Text Available In this paper we study the methodology employed for preprocessing the archaeological images. We present the various algorithms used in the low-level processing stage of image analysis for Optical Character Recognition System for Brahmi Script. The image preprocessing technique covered in this paper is thresholding. We also try to analyze the results obtained by the pixel-level processing algorithms.

  14. MR imaging of the various stages of normal myelination during the first year of life

    International Nuclear Information System (INIS)

    Knaap, M.S. van der; Valk, J.

    1990-01-01

    The normal process of myelination of the brain mainly occurs during the first year of life. This process as known from histology can be visualized by MRI. Because of the very long T1 and T2 of immature brain tissue it is necessary to use adjusted pulse sequences with a long TR in order to obtain sufficient tissue contrast. With long TR SE images five stages can be recognized in the process of normal myelination and brain maturation. During the first month of life long TR short TE SE images show what are believed to be myelinated structures by correlation with published histological studies with a high signal intensity, unmyelinated white matter with a low signal intensity and gray matter with an intermediate signal intensity. The signal intensity of unmyelinated and myelinated white matter is reversed on long TR long TE SE images. In the course of a few weeks the signal intensity of unmyelinated white matter becomes high and the signal intensity of myelinated white matter becomes low also on long TR short TE SE images. These changes are believed to be caused by a loss of water and a change in chemical composition of brain tissue just prior to the onset of a wave of myelination. With progression of myelination the signal intensity of white matter changes from high to intermediate to low. These changes result in stages of isointensity, first in the central parts of the brain, later in the lobar parts. At the end of the first year the adult contrast pattern is reached in all parts of the brain. IR images are also able to depict the progress of myelination, but appear to be less sensitive to subtle changes in the degree of myelination. The precise normal values for the five stages depend on the magnetic field strength and the pulse sequences used. (orig.)

  15. UTILIZATION OF FUNDUS AUTOFLUORESCENCE, SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY, AND ENHANCED DEPTH IMAGING IN THE CHARACTERIZATION OF BIETTI CRYSTALLINE DYSTROPHY IN DIFFERENT STAGES.

    Science.gov (United States)

    Li, Qian; Li, Yang; Zhang, Xiaohui; Xu, Zhangxing; Zhu, Xiaoqing; Ma, Kai; She, Haicheng; Peng, Xiaoyan

    2015-10-01

    To characterize Bietti crystalline dystrophy (BCD) in different stages using multiple imaging modalities. Sixteen participants clinically diagnosed as BCD were included in the retrospective study and were categorized into 3 stages according to fundus photography. Eleven patients were genetically confirmed. Fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging features of BCD were analyzed. On fundus autofluorescence, the abnormal autofluorescence was shown to enlarge in area and decrease in intensity with stages. Using spectral domain optical coherence tomography, the abnormalities in Stage 1 were observed to localize in outer retinal layers, whereas in Stage 2 and Stage 3, more extensive retinal atrophy was seen. In enhanced depth imaging, the subfoveal choroidal layers were delineated clearly in Stage 1; in Stage 2, destructions were primarily found in the choriocapillaris with associated alterations in the outer vessels; Stage 3 BCD displayed severe choroidal thinning. Choroidal neovascularization and macular edema were exhibited with high incidence. IVS6-8del17bp/inGC of the CYP4V2 gene was the most common mutant allele. Noninvasive fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging may help to characterize the chorioretinal pathology of BCD at different degrees, and therefore, we propose staging of BCD depending on those methods. Physicians should be cautious of the vision-threatening complications of the disease.

  16. Imaging system design and image interpolation based on CMOS image sensor

    Science.gov (United States)

    Li, Yu-feng; Liang, Fei; Guo, Rui

    2009-11-01

    An image acquisition system is introduced, which consists of a color CMOS image sensor (OV9620), SRAM (CY62148), CPLD (EPM7128AE) and DSP (TMS320VC5509A). The CPLD implements the logic and timing control to the system. SRAM stores the image data, and DSP controls the image acquisition system through the SCCB (Omni Vision Serial Camera Control Bus). The timing sequence of the CMOS image sensor OV9620 is analyzed. The imaging part and the high speed image data memory unit are designed. The hardware and software design of the image acquisition and processing system is given. CMOS digital cameras use color filter arrays to sample different spectral components, such as red, green, and blue. At the location of each pixel only one color sample is taken, and the other colors must be interpolated from neighboring samples. We use the edge-oriented adaptive interpolation algorithm for the edge pixels and bilinear interpolation algorithm for the non-edge pixels to improve the visual quality of the interpolated images. This method can get high processing speed, decrease the computational complexity, and effectively preserve the image edges.

  17. The relationships between memory systems and sleep stages.

    Science.gov (United States)

    Rauchs, Géraldine; Desgranges, Béatrice; Foret, Jean; Eustache, Francis

    2005-06-01

    Sleep function remains elusive despite our rapidly increasing comprehension of the processes generating and maintaining the different sleep stages. Several lines of evidence support the hypothesis that sleep is involved in the off-line reprocessing of recently-acquired memories. In this review, we summarize the main results obtained in the field of sleep and memory consolidation in both animals and humans, and try to connect sleep stages with the different memory systems. To this end, we have collated data obtained using several methodological approaches, including electrophysiological recordings of neuronal ensembles, post-training modifications of sleep architecture, sleep deprivation and functional neuroimaging studies. Broadly speaking, all the various studies emphasize the fact that the four long-term memory systems (procedural memory, perceptual representation system, semantic and episodic memory, according to Tulving's SPI model; Tulving, 1995) benefit either from non-rapid eye movement (NREM) (not just SWS) or rapid eye movement (REM) sleep, or from both sleep stages. Tulving's classification of memory systems appears more pertinent than the declarative/non-declarative dichotomy when it comes to understanding the role of sleep in memory. Indeed, this model allows us to resolve several contradictions, notably the fact that episodic and semantic memory (the two memory systems encompassed in declarative memory) appear to rely on different sleep stages. Likewise, this model provides an explanation for why the acquisition of various types of skills (perceptual-motor, sensory-perceptual and cognitive skills) and priming effects, subserved by different brain structures but all designated by the generic term of implicit or non-declarative memory, may not benefit from the same sleep stages.

  18. Stage III nasopharyngeal angiofibroma: Improving results with endoscopic-assisted midfacial degloving and modification to the Fisch staging system.

    Science.gov (United States)

    Shah, Saurin R; Keshri, Amit; Patadia, Simple; Sahu, Rabi Narayan; Srivastava, Arun Kumar; Behari, Sanjay

    2015-10-01

    To study outcomes with endoscopic-assisted midfacial degloving for Fisch stage III nasopharyngeal angiofibroma and propose a new staging system. Retrospective study of patients with Fisch stage III juvenile nasopharyngeal angiofibroma (JNA) including preoperative angiography, intraoperative blood loss and residue/recurrence following surgery. Tertiary care superspecialty referral center. Fifteen consecutive patients with Fisch stage III JNA undergoing operations over a period of 18 months. Preoperative angiography details, intraoperative blood loss, residue/recurrence, complications of surgery. Transarterial embolization with particulate agents followed by endoscopic-assisted midfacial degloving provides excellent outcomes with Fisch stage III JNAs. The modified Fisch staging system proposed would allow better preoperative evaluation and comparison of outcomes with different treatment options for stage III JNAs. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  20. Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Cen [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); First Affiliated Hospital of Soochow University, Department of Radiology, Suzhou (China); Zhang, Huan; Du, Lianjun; Pan, Zilai; Yan, Fuhua [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Yan, Jing [Siemens Medical System, Shanghai (China); Wang, Baisong [Shanghai Jiao Tong University School of Medicine, Department of Biological Statistics, Shanghai (China)

    2017-02-15

    To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). 31 EGC patients (19 men, 12 women; age range, 38-81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated. AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC. (orig.)

  1. Fluorescence background subtraction technique for hybrid fluorescence molecular tomography/x-ray computed tomography imaging of a mouse model of early stage lung cancer.

    Science.gov (United States)

    Ale, Angelique; Ermolayev, Vladimir; Deliolanis, Nikolaos C; Ntziachristos, Vasilis

    2013-05-01

    The ability to visualize early stage lung cancer is important in the study of biomarkers and targeting agents that could lead to earlier diagnosis. The recent development of hybrid free-space 360-deg fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) imaging yields a superior optical imaging modality for three-dimensional small animal fluorescence imaging over stand-alone optical systems. Imaging accuracy was improved by using XCT information in the fluorescence reconstruction method. Despite this progress, the detection sensitivity of targeted fluorescence agents remains limited by nonspecific background accumulation of the fluorochrome employed, which complicates early detection of murine cancers. Therefore we examine whether x-ray CT information and bulk fluorescence detection can be combined to increase detection sensitivity. Correspondingly, we research the performance of a data-driven fluorescence background estimator employed for subtraction of background fluorescence from acquisition data. Using mice containing known fluorochromes ex vivo, we demonstrate the reduction of background signals from reconstructed images and sensitivity improvements. Finally, by applying the method to in vivo data from K-ras transgenic mice developing lung cancer, we find small tumors at an early stage compared with reconstructions performed using raw data. We conclude with the benefits of employing fluorescence subtraction in hybrid FMT-XCT for early detection studies.

  2. Imaging efficacy of a targeted imaging agent for fluorescence endoscopy

    Science.gov (United States)

    Healey, A. J.; Bendiksen, R.; Attramadal, T.; Bjerke, R.; Waagene, S.; Hvoslef, A. M.; Johannesen, E.

    2008-02-01

    Colorectal cancer is a major cause of cancer death. A significant unmet clinical need exists in the area of screening for earlier and more accurate diagnosis and treatment. We have identified a fluorescence imaging agent targeted to an early stage molecular marker for colorectal cancer. The agent is administered intravenously and imaged in a far red imaging channel as an adjunct to white light endoscopy. There is experimental evidence of preclinical proof of mechanism for the agent. In order to assess potential clinical efficacy, imaging was performed with a prototype fluorescence endoscope system designed to produce clinically relevant images. A clinical laparoscope system was modified for fluorescence imaging. The system was optimised for sensitivity. Images were recorded at settings matching those expected with a clinical endoscope implementation (at video frame rate operation). The animal model was comprised of a HCT-15 xenograft tumour expressing the target at concentration levels expected in early stage colorectal cancer. Tumours were grown subcutaneously. The imaging agent was administered intravenously at a dose of 50nmol/kg body weight. The animals were killed 2 hours post administration and prepared for imaging. A 3-4mm diameter, 1.6mm thick slice of viable tumour was placed over the opened colon and imaged with the laparoscope system. A receiver operator characteristic analysis was applied to imaging results. An area under the curve of 0.98 and a sensitivity of 87% [73, 96] and specificity of 100% [93, 100] were obtained.

  3. Advances in the staging of renal cell carcinoma with high-resolution imaging; Fortschritte im Staging des Nierenzellkarzinoms mittels hochaufloesender Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hallscheidt, P.; Noeldge, G.; Schawo, S.; Kauffmann, G.; Palmowski, M. [Abt. Radiodiagnostik, Radiologische Klinik, Univ. Heidelberg (Germany); Bartling, S. [Medizinische Physik, DKFZ Heidelberg (Germany); Pfitzenmaier, J. [Urologische Klinik, Univ. Heidelberg (Germany)

    2007-12-15

    Modern imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI) allow high-resolution imaging of the abdomen. Modern scanners made high temporal as well as high spatial resolution available. Therapeutic approaches to the treatment of renal cell carcinoma have been improved over the recent years. Besides conventional and open laparoscopic tumor nephrectomy and nephron sparing, surgical approaches such as local tumor cryotherapy and radiofrequency ablation (RF) are ablative modalities and are used increasingly. Improved anesthesiological methods and new surgical approaches also allow curative treatment in extended tumors. Prerequisites for preoperative imaging modalities include visualization of the kidney tumor as well as its staging. Tumor-related infiltration of the renal pelvis or invasion of the perinephric fat and the renal hilus has to be excluded prior to nephron sparing surgery. In cases with extended tumors with infiltration of the inferior vena cava, it is necessary to visualize the exact extension of the tumor growth towards the right atrium in the vena cava. The radiologist should be informed about the diagnostic possibilities and limitations of the imaging modalities of CT and MRI in order to support the urologist in the planning and performance of surgical therapeutical approaches. (orig.)

  4. Comparison of PET-CT and magnetic resonance diffusion weighted imaging with body suppression (DWIBS) for initial staging of malignant lymphomas

    Energy Technology Data Exchange (ETDEWEB)

    Stéphane, Velasco, E-mail: stephane.velasco@chu-poitiers.fr [Department of Radiology, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Samuel, Burg, E-mail: s.burg@chu-poitiers.fr [Department of Nuclear Medicine, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Department of Nuclear Medicine, Saint-Louis Hospital, Paris CHU Saint Louis, 40 rue de Bichat, 75 010 Paris (France); Vincent, Delwail, E-mail: v.delwail@chu-poitiers.fr [Department of Hematology, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Joelle, Guilhot, E-mail: j.guilhot@chu-poitiers.fr [Department of Hematology, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Remy, Perdrisot, E-mail: r.perdrisot@chu-poitiers.fr [Department of Nuclear Medicine, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Francois, Guilhot Gaudeffroy, E-mail: f.guilhot-gaudeffroy@chu-poitiers.fr [Department of Hematology, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France); Jean-Pierre, Tasu, E-mail: j.p.tasu@chu-poitiers.fr [Department of Radiology, CHU de Poitiers, rue de la milétrie, 86000 Poitiers (France)

    2013-11-01

    Objective: To evaluate the clinical impact of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in staging of malignant lymphoma. Methods: Twenty-three patients with proven malignant lymphomas were prospectively enrolled. DWIBS (b = 0, 1000 s/mm{sup 2}) examinations and PET-CT were performed respectively on an Intera 1.5 T unit and a Gyroscan PET-CT scan (Philips Medical system, Best, the Netherland). The criteria for positive node involvement were a size over 10 mm or an apparent diffusion coefficient (ADC) value under 0.75 10{sup −3} mm{sup 2}/s for nodes under 10 mm. For extranodal analysis, a high or heterogeneous signal on DWIBS was considered as positive. In cases of discordance, the reference standard for each region or organ was established at 6 months after the diagnosis according to all available clinical, biological information, as well as histological evidence or follow-up to prove or disprove the presence of disease. Results: DWIBS and PET-CT results were congruent in 333 node regions on the 345 areas analyzed, with excellent agreement (κ = 0.97, P < 0.0001). From 433 organs analyzed (one patient had splenectomy) extranodal disease was detected in 22 organs on DWIBS. The two imaging techniques agreed on 430 organs (κ = 0.99, P < 0.0001). Finally, Ann Arbor stages based on DWIBS and those of PET/CT were in agreement for 23 patients. Conclusions: For malignant lymphoma in a pre-therapeutic context, agreement between diffusion-weighted whole-body imaging and PET/CT is high for Ann Arbor staging.

  5. Comparison of PET-CT and magnetic resonance diffusion weighted imaging with body suppression (DWIBS) for initial staging of malignant lymphomas

    International Nuclear Information System (INIS)

    Stéphane, Velasco; Samuel, Burg; Vincent, Delwail; Joelle, Guilhot; Remy, Perdrisot; Francois, Guilhot Gaudeffroy; Jean-Pierre, Tasu

    2013-01-01

    Objective: To evaluate the clinical impact of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in staging of malignant lymphoma. Methods: Twenty-three patients with proven malignant lymphomas were prospectively enrolled. DWIBS (b = 0, 1000 s/mm 2 ) examinations and PET-CT were performed respectively on an Intera 1.5 T unit and a Gyroscan PET-CT scan (Philips Medical system, Best, the Netherland). The criteria for positive node involvement were a size over 10 mm or an apparent diffusion coefficient (ADC) value under 0.75 10 −3 mm 2 /s for nodes under 10 mm. For extranodal analysis, a high or heterogeneous signal on DWIBS was considered as positive. In cases of discordance, the reference standard for each region or organ was established at 6 months after the diagnosis according to all available clinical, biological information, as well as histological evidence or follow-up to prove or disprove the presence of disease. Results: DWIBS and PET-CT results were congruent in 333 node regions on the 345 areas analyzed, with excellent agreement (κ = 0.97, P < 0.0001). From 433 organs analyzed (one patient had splenectomy) extranodal disease was detected in 22 organs on DWIBS. The two imaging techniques agreed on 430 organs (κ = 0.99, P < 0.0001). Finally, Ann Arbor stages based on DWIBS and those of PET/CT were in agreement for 23 patients. Conclusions: For malignant lymphoma in a pre-therapeutic context, agreement between diffusion-weighted whole-body imaging and PET/CT is high for Ann Arbor staging

  6. Image quality of digital mammography images produced using wet and dry laser imaging systems

    International Nuclear Information System (INIS)

    Al Khalifah, K.; Brindhaban, A.; AlArfaj, R.; Jassim, O.

    2006-01-01

    Introduction: A study was carried out to compare the quality of digital mammographic images printed or processed by a wet laser imaging system and a dedicated mammographic dry laser imaging system. Material and methods: Digital images of a tissue equivalent breast phantom were obtained using a GE Senographe 2000D digital mammography system and different target/filter combinations of the X-ray tube. These images were printed on films using the Fuji FL-IM D wet laser imaging system and the Kodak DryView 8600 dry laser imaging system. The quality of images was assessed in terms of detectability of microcalcifications and simulated tumour masses by five radiologists. In addition, the contrast index and speed index of the two systems were measured using the step wedge in the phantom. The unpaired, unequal variance t-test was used to test any statistically significant differences. Results: There were no significant (p < 0.05) differences between the images printed using the two systems in terms of microcalcification and tumour mass detectability. The wet system resulted in slightly higher contrast index while the dry system showed significantly higher speed index. Conclusion: Both wet and dry laser imaging systems can produce mammography images of good quality on which 0.2 mm microcalcifications and 2 mm tumour masses can be detected. Dry systems are preferable due to the absence of wet chemical processing and solid or liquid chemical waste. The wet laser imaging systems, however, still represent a useful alternative to dry laser imaging systems for mammography studies

  7. Advances in the staging of renal cell carcinoma with high-resolution imaging

    International Nuclear Information System (INIS)

    Hallscheidt, P.; Noeldge, G.; Schawo, S.; Kauffmann, G.; Palmowski, M.; Bartling, S.; Pfitzenmaier, J.

    2007-01-01

    Modern imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI) allow high-resolution imaging of the abdomen. Modern scanners made high temporal as well as high spatial resolution available. Therapeutic approaches to the treatment of renal cell carcinoma have been improved over the recent years. Besides conventional and open laparoscopic tumor nephrectomy and nephron sparing, surgical approaches such as local tumor cryotherapy and radiofrequency ablation (RF) are ablative modalities and are used increasingly. Improved anesthesiological methods and new surgical approaches also allow curative treatment in extended tumors. Prerequisites for preoperative imaging modalities include visualization of the kidney tumor as well as its staging. Tumor-related infiltration of the renal pelvis or invasion of the perinephric fat and the renal hilus has to be excluded prior to nephron sparing surgery. In cases with extended tumors with infiltration of the inferior vena cava, it is necessary to visualize the exact extension of the tumor growth towards the right atrium in the vena cava. The radiologist should be informed about the diagnostic possibilities and limitations of the imaging modalities of CT and MRI in order to support the urologist in the planning and performance of surgical therapeutical approaches. (orig.)

  8. Textural features of pretreatment 18F-FDG PET/CT images: prognostic significance in patients with advanced T-stage oropharyngeal squamous cell carcinoma.

    Science.gov (United States)

    Cheng, Nai-Ming; Fang, Yu-Hua Dean; Chang, Joseph Tung-Chieh; Huang, Chung-Guei; Tsan, Din-Li; Ng, Shu-Hang; Wang, Hung-Ming; Lin, Chien-Yu; Liao, Chun-Ta; Yen, Tzu-Chen

    2013-10-01

    Previous studies have shown that total lesion glycolysis (TLG) may serve as a prognostic indicator in oropharyngeal squamous cell carcinoma (OPSCC). We sought to investigate whether the textural features of pretreatment (18)F-FDG PET/CT images can provide any additional prognostic information over TLG and clinical staging in patients with advanced T-stage OPSCC. We retrospectively analyzed the pretreatment (18)F-FDG PET/CT images of 70 patients with advanced T-stage OPSCC who had completed concurrent chemoradiotherapy, bioradiotherapy, or radiotherapy with curative intent. All of the patients had data on human papillomavirus (HPV) infection and were followed up for at least 24 mo or until death. A standardized uptake value (SUV) of 2.5 was taken as a cutoff for tumor boundary. The textural features of pretreatment (18)F-FDG PET/CT images were extracted from histogram analysis (SUV variance and SUV entropy), normalized gray-level cooccurrence matrix (uniformity, entropy, dissimilarity, contrast, homogeneity, inverse different moment, and correlation), and neighborhood gray-tone difference matrix (coarseness, contrast, busyness, complexity, and strength). Receiver-operating-characteristic curves were used to identify the optimal cutoff values for the textural features and TLG. Thirteen patients were HPV-positive. Multivariate Cox regression analysis showed that age, tumor TLG, and uniformity were independently associated with progression-free survival (PFS) and disease-specific survival (DSS). TLG, uniformity, and HPV positivity were significantly associated with overall survival (OS). A prognostic scoring system based on TLG and uniformity was derived. Patients who presented with TLG > 121.9 g and uniformity ≤ 0.138 experienced significantly worse PFS, DSS, and OS rates than those without (P 121.9 g or uniformity ≤ 0.138 were further divided according to age, and different PFS and DSS were observed. Uniformity extracted from the normalized gray

  9. GRANITE- A steroscopic imaging Chernkov telescope system

    International Nuclear Information System (INIS)

    Shubnell, M.; Akerlof, C.W.; Cawley, M.F.; Chantell, M.; Fegan, D.J.; Fennell, S.; O'Flaherty, K.S.; Freeman, S.; Frishman, D.; Gaidos, J.A.; Hagan, J.; Harris, K.; Hillas, A.M.; Kerrick, A.D.; Lamb, R.C.; Lappin, T.; Lawrence, M.A.; Levy, H.; Lewis, D.A.; Meyer, D.I.; Mohanty, G.; Punch, M.; Reynolds, P.T.; Rovero, A.C.; Sembroski, G.; Weaverdyck, C.; Weekes, T.C.; Whitaker, T.; Wilson, C.

    1993-01-01

    A second 10 meter class imaging telescope was constructed on Mt. Hopkins, Arizona, the site of the original 10 meter Whipple Cherenkov telescope. The twin telescope system with a 140 meter base line will allow both a reduction in the energy threshold and an improvement in the rejection of the hardonic background. The new telescope started operation in December 1991. With the final completion of the first installation stage (GRANITE I) during spring 92, it is now operating simultaneously with the orginal reflector. We describe in this paper design and construction of the new instrument and demonstrate the capability of the experiment to record coincident events

  10. Role of imaging in the staging and response assessment of lymphoma

    DEFF Research Database (Denmark)

    Barrington, Sally F; Mikhaeel, N George; Kostakoglu, Lale

    2014-01-01

    emission tomography (PET)–computed tomography (CT). Progress in imaging is influencing trial design and affecting clinical practice. In particular, a five-point scale to grade response using PET-CT, which can be adapted to suit requirements for early- and late-response assessment with good interobserver....... CONCLUSION: This article comprises the consensus reached to update guidance on the use of PET-CT for staging and response assessment for [18F]fluorodeoxyglucose-avid lymphomas in clinical practice and late-phase trials....

  11. Prospective, blinded trial of whole-body magnetic resonance imaging versus computed tomography positron emission tomography in staging primary and recurrent cancer of the head and neck.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    OBJECTIVES: To compare the use of computed tomography - positron emission tomography and whole-body magnetic resonance imaging for the staging of head and neck cancer. PATIENTS AND METHODS: From January to July 2009, 15 consecutive head and neck cancer patients (11 men and four women; mean age 59 years; age range 19 to 81 years) underwent computed tomography - positron emission tomography and whole-body magnetic resonance imaging for pre-therapeutic evaluation. All scans were staged, as per the American Joint Committee on Cancer tumour-node-metastasis classification, by two blinded consultant radiologists, in two sittings. Diagnoses were confirmed by histopathological examination of endoscopic biopsies, and in some cases whole surgical specimens. RESULTS: Tumour staging showed a 74 per cent concordance, node staging an 80 per cent concordance and metastasis staging a 100 per cent concordance, comparing the two imaging modalities. CONCLUSION: This study found radiological staging discordance between the two imaging modalities. Whole-body magnetic resonance imaging is an emerging staging modality with superior visualisation of metastatic disease, which does not require exposure to ionising radiation.

  12. Staging of endometrial cancer with MRI: Guidelines of the European Society of Urogenital Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinkel, K. [Geneva University Hospital and Institut de Radiologie, Clinique des Grangettes, Chene-Bougeries/Geneva (Switzerland); Clinique des Grangettes, Institut de radiologie, Chene-Bougerie/Geneva (Switzerland); Forstner, R. [LandesklinikenSalzburg, Zentralroentgeninstitut, Salzburg (Austria); Danza, F.M. [Universita Cattolica del S. Cuore, Dipartimento di Bioimmagini e scienze radiologiche, Rome (Italy); Oleaga, L. [Hospital Clinic, Radiology Department, Barcelona (Spain); Cunha, T.M. [Instituto Portugues de Oncologia de Lisboa Francisco Gentil, Department of Radiology, Lisboa Codex (Portugal); Bergman, A. [Uppsala University Hospital, Department of Radiology, Uppsala (Sweden); Barentsz, J.O. [Radboud University Nijmegen Medical Center, Department of Radiology, Nijmegen (Netherlands); Balleyguier, C. [Institut de Cancerologie Gustave Roussy, Department of Radiology, Villejuif Cedex (France); Brkljacic, B. [University Hospital ' ' Dubrava' ' , Department of Diagnostic and Interventional Radiology, Zagreb (Croatia); University of Zagreb, Medical School, Zagreb (Croatia); Spencer, J.A. [St James' s Institute of Oncology, Department of Clinical Radiology, Leeds (United Kingdom)

    2009-07-15

    The purpose of this study was to define guidelines for endometrial cancer staging with MRI. The technique included critical review and expert consensus of MRI protocols by the female imaging subcommittee of the European Society of Urogenital Radiology, from ten European institutions, and published literature between 1999 and 2008. The results indicated that high field MRI should include at least two T2-weighted sequences in sagittal, axial oblique or coronal oblique orientation (short and long axis of the uterine body) of the pelvic content. High-resolution post-contrast images acquired at 2 min {+-} 30 s after intravenous contrast injection are suggested to be optimal for the diagnosis of myometrial invasion. If cervical invasion is suspected, additional slice orientation perpendicular to the axis of the endocervical channel is recommended. Due to the limited sensitivity of MRI to detect lymph node metastasis without lymph node-specific contrast agents, retroperitoneal lymph node screening with pre-contrast sequences up to the level of the kidneys is optional. The likelihood of lymph node invasion and the need for staging lymphadenectomy are also indicated by high-grade histology at endometrial tissue sampling and by deep myometrial or cervical invasion detected by MRI. In conclusion, expert consensus and literature review lead to an optimized MRI protocol to stage endometrial cancer. (orig.)

  13. Perspectives in Molecular Imaging Using Staging Biomarkers and Immunotherapies in Alzheimer’s Disease

    Directory of Open Access Journals (Sweden)

    Benoît Leclerc

    2013-01-01

    Full Text Available Sporadic Alzheimer’s disease (AD is an emerging chronic illness characterized by a progressive pleiotropic pathophysiological mode of actions triggered during the senescence process and affecting the elderly worldwide. The complex molecular mechanisms of AD not only are supported by cholinergic, beta-amyloid, and tau theories but also have a genetic basis that accounts for the difference in symptomatology processes activation among human population which will evolve into divergent neuropathological features underlying cognitive and behaviour alterations. Distinct immune system tolerance could also influence divergent responses among AD patients treated by immunotherapy. The complexity in nature increases when taken together the genetic/immune tolerance with the patient’s brain reserve and with neuropathological evolution from early till advance AD clinical stages. The most promising diagnostic strategies in today’s world would consist in performing high diagnostic accuracy of combined modality imaging technologies using beta-amyloid 42 peptide-cerebrospinal fluid (CSF positron emission tomography (PET, Pittsburgh compound B-PET, fluorodeoxyglucose-PET, total and phosphorylated tau-CSF, and volumetric magnetic resonance imaging hippocampus biomarkers for criteria evaluation and validation. Early diagnosis is the challenge task that needs to look first at plausible mechanisms of actions behind therapies, and combining them would allow for the development of efficient AD treatment in a near future.

  14. Overview of current multiparametric magnetic resonance imaging approach in the diagnosis and staging of prostate cancer

    Directory of Open Access Journals (Sweden)

    Hasan Aydın

    2015-04-01

    Full Text Available This article is primarily based on the utility and validity of multiparametric magnetic resonance imaging in the diagnosis and staging of prostate gland tumors. Multiparametric magnetic resonance imaging is an emerging, useful approach for evaluating and detecting prostate cancers. It also aids in the management of a tumor and improve the care and follow-up of patients.

  15. Improved Interactive Medical-Imaging System

    Science.gov (United States)

    Ross, Muriel D.; Twombly, Ian A.; Senger, Steven

    2003-01-01

    An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

  16. Staging of Klatskin tumours (hilar cholangiocarcinomas): comparison of MR cholangiography, MR imaging, and endoscopic retrograde cholangiography

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Schwarz, Wolfram O.; Heller, Matthias; Herzog, Christopher; Zangos, Stephan; Hammerstingl, Renate M.; Hintze, Rainer E.; Neuhaus, Peter

    2006-01-01

    The aim of the study was to compare prospectively magnetic resonance cholangiography (MRC) and magnetic resonance imaging (MRI) with endoscopic retrograde cholangiography (ERC) in the diagnosis and staging of Klatskin tumours of the biliary tree (hilar cholangiocarcinomas). Forty-six patients with suspected Klatskin tumours of the biliary tract underwent MRI and heavily T2-weighted, non-breathhold, respiratory-triggered fast spin-echo MRC. Forty-two patients underwent ERC within 24 h; in four patients, ERC was not feasible, and percutaneous trans-hepatic cholangiography (PTC) was carried out instead. Two independent investigators evaluated imaging results for the presence of tumour, bile duct dilatation, and stenosis. Clinical and histopathological correlation revealed Klatskin tumours in 33 patients. MRI revealed a slightly hyperintense signal of infiltrated bile ducts in T2-weighted fast spin-echo sequences. The malignant lesion was regularly visualized as a hypointense area in T1-weighted gradient-echo sequences with substantial contrast enhancement along the involved bile duct walls. MRC revealed the location and extension of the tumour in 31 of 33 cases correctly (sensitivity 94%, specificity 100%, diagnostic accuracy 95%). In 27 of 31 cases, ERC enabled accurate staging and diagnosis of Klatskin tumours with a sensitivity of 87%. ERC and PTC combined yielded a sensitivity of 84% and a specificity of 97%. Tumours were grouped according to the Bismuth classification, with MRC allowing correct identification of type I tumour in seven patients, type II tumour in four patients, type III tumour in 12 patients, and type IV tumour in ten patients. MRC provided superior visualization of completely obstructed peripheral systems. MRC in combination with MRI is a reliable non-invasive diagnostic method for the pre-therapeutic staging of Klatskin tumours. (orig.)

  17. Evaluation of the AJCC 8th Edition Staging System for Pathologically Versus Clinically Staged Intrahepatic Cholangiocarcinoma (iCCA): a Time to Revisit a Dogma? A Surveillance, Epidemiology, and End Results (SEER) Analysis.

    Science.gov (United States)

    Kamarajah, Sivesh K

    2018-03-07

    Recently, the AJCC has released its 8th edition changes to the staging system for intrahepatic cholangiocarcinoma (iCCA). This study sought to validate the proposed changes to the 8th edition of AJCC system for T and N classification of iCCA using a population-based data set. Using the Surveillance, Epidemiology, and End Results (SEER) database (1998-2013), patients undergoing resection or non-surgical management for non-metastatic iCCA were identified. Overall survival was estimated using the Kaplan-Meier method and compared using log-rank tests. Concordance indices (c-indices) calculated from Cox proportional hazards models were calculated to evaluate discriminatory power. The study included 2630 patients resected (37%) or non-surgically managed (63%) for iCCA. Nodal staging was performed in 56%, of whom 31% had positive nodes. For all patients with iCCA, the median 5-year survival by AJCC T classification for T1a, T1b, T2, T3, and T4 was 32, 21, 14, 10, and 10 months, respectively (p < 0.001). The concordance index for the staging system was 0.57 for all patients, 0.62 for those who underwent resection, and 0.54 for patients who did not undergo resection. In summary, the new AJCC 8th edition staging system is comparable to the 7th edition and valid in stratifying patients with iCCA. However, the performance of the staging system is better in patients undergoing surgical resection than those undergoing non-surgical management. These findings further highlight the need for improved accuracy of radiological imaging in clinically staging patients to guide prognosis.

  18. Clinical-pathologic correlation in early cervical carcinoma: CT-MR imaging comparison for effect on staging and treatment choices

    International Nuclear Information System (INIS)

    Rubens, D.; Thornbury, J.R.; Weiss, S.L.; Lerner, R.M.; Angel, C.; Beecham, J.; Stoler, M.H.

    1986-01-01

    A group of patients with clinical stage I or II squamous cell cervical carcinoma have been examined using a 1.5-T magnet. Of these, six have had radical hysterectomy (by April 1986), providing specimens for pathologic correlation. In this preliminary group of patients, MR imaging gave a more accurate assessment of primary tumor extent than did clinical staging. In three of six patients, the disease was underestimated clinically at examination under anesthesia. These patients would have been managed with preoperative radiation rather than surgery alone if the investigative MR imaging information had been used in treatment planning. CT examinations of these patients did not contribute useful information for patient management. Preoperative MR imaging has the potential to alter patient treatment in early cervical carcinoma

  19. Preoperative CT prediction for Masaoka staging of thymic epithelial tumor

    International Nuclear Information System (INIS)

    Feng Zhan; Huang Zhen; Zhang Liang

    2013-01-01

    Objective: To discuss the value of CT prognosis on the Masaoka staging system of thymic epithelial tumors (TET) before surgical resection. Methods: The CT images of 102 patients with TET proved by surgery and pathology were reviewed retrospectively. The TET were reclassified according to Masaoka stage system. The size, homogeneity, sharp, contour, infiltration of surrounding tissue, and metastasis on CT were analyzed with Logistic analysis. The diagnostic value was also evaluated with a ROC curve. Results: Masaoka pathologic stages were stage Ⅰ for 36 (35.3 %), stage Ⅱ for 27 (26.5 %), stage Ⅲ for 30 (29.4 %), and stage Ⅳ for 9 (8.8 %). A multivariable Logistic regression model showed that TET with larger size of tumor (20/35, P = 0.0371, OR = 4.539), irregular or lobulated tumor contour (26/42, P = 0.0230, OR = 4.870), heterogeneous (21/33, P = 0.0154, OR = 6.020), infiltration of surrounding fat (25/32, P = 0.0019, OR = 14.005), and pleural seeding (11/11, P = 0.0032, OR = 36.153) were more likely to have stage Ⅲ or Ⅳ disease. The area under ROC curve was 0.940. Conclusions: The tumor CT imaging features can differentiate between stage Ⅰ, Ⅱ and stage Ⅲ, Ⅳ disease. This helps identified patients more likely to benefit from neoadjuvant therapy. (authors)

  20. Comparison of five systems for staging lymph node metastasis in gastric cancer.

    Science.gov (United States)

    Yu, W; Choi, G S; Whang, I; Suh, I S

    1997-09-01

    There are several systems for staging lymph node metastasis in gastric cancer. Their relative merits are not clear. In this retrospective analysis, the nodal status was classified according to the Union Internacional Contra la Cancrum (UICC) and Japanese staging systems, the number and frequency of lymph node metastasis, and the level of involved nodes. Each staging system was scored as good (+1), fair (0) or poor (-1) with respect to prognostic value, theoretical value, convenience, reproducibility and surgical applicability. There were no differences between the five staging systems in predicting survival. The Japanese staging system was most arbitrary owing to the complexity of the system, although it had an advantage in surgical application. The same disadvantage was found in the UICC system and the level system. Determination of the number and frequency of involved nodes was convenient and reproducible, but the number of lymph nodes dissected must be considered when the number of positive nodes is used for staging. The classification of metastasis to the regional lymph nodes as N0 (no nodal metastasis), N1 (metastasis in 1-25 per cent of dissected nodes) and N2 (metastasis in more than 25 per cent of dissected nodes) would be a simple, convenient, reproducible staging system with an ability to predict surgical results.

  1. A semi-symmetric image encryption scheme based on the function projective synchronization of two hyperchaotic systems.

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Di

    Full Text Available Both symmetric and asymmetric color image encryption have advantages and disadvantages. In order to combine their advantages and try to overcome their disadvantages, chaos synchronization is used to avoid the key transmission for the proposed semi-symmetric image encryption scheme. Our scheme is a hybrid chaotic encryption algorithm, and it consists of a scrambling stage and a diffusion stage. The control law and the update rule of function projective synchronization between the 3-cell quantum cellular neural networks (QCNN response system and the 6th-order cellular neural network (CNN drive system are formulated. Since the function projective synchronization is used to synchronize the response system and drive system, Alice and Bob got the key by two different chaotic systems independently and avoid the key transmission by some extra security links, which prevents security key leakage during the transmission. Both numerical simulations and security analyses such as information entropy analysis, differential attack are conducted to verify the feasibility, security, and efficiency of the proposed scheme.

  2. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    International Nuclear Information System (INIS)

    Rollven, Erik; Blomqvist, Lennart; Holm, Torbjorn; Glimelius, Bengt; Loerinc, Esther

    2013-01-01

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion

  3. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rollven, Erik; Blomqvist, Lennart [Dept. of Diagnostic Radiology, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden)], e-mail: erik.rollven@ki.se; Holm, Torbjorn [Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden); Dept. of Surgery, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Glimelius, Bengt [Dept. of Radiology, Oncology and Radiation Science, Uppsala Univ., Uppsala (Sweden); Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Loerinc, Esther [Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Dept. of Pathology, Karolinska Univ. Hospital, Solna, Sweden (Sweden)

    2013-09-15

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion.

  4. NP-59 SPECT/CT Imaging in Stage 1 Hypertensive and Atypical Primary Aldosteronism: A 5-Year Retrospective Analysis of Clinicolaboratory and Imaging Features

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chen

    2013-01-01

    Full Text Available Objective. We retrospectively analyzed all primary aldosteronism (PA patients undergoing NP-59 SPECT/CT imaging with regard to their clinicolaboratory and imaging features, investigation, and outcomes. Material and Methods. 11 PA patients who presented to our hospital for NP-59 SPECT/CT imaging between April 2007 and March 2012 and managed here were analyzed. Results. Among 11 PA patients, eight (73% had stage 1 hypertension, three (27% stage 2 hypertension, four (36% normal plasma aldosterone concentration, nine (82% nonsuppressed plasma renin activity (PRA, six (55% normal aldosterone-renin-ratio (ARR, eight (73% serum potassium ≧3 mEq/L, seven (64% subclinical presentation, seven (64% negative confirmatory testing, and four (36% inconclusive results on CT scan and seven (64% on planar NP-59 scan. All 11 (100% patients had positive results on NP-59 SPECT/CT scan. Two (18% met typical triad and nine (82% atypical triad. Among nine atypical PA patients, three (33% had clinical presentation, six (67% subclinical presentation, six (67% negative confirmatory testing, and four (44% inconclusive results on CT scan and six (67% on planar NP-59 scan. All patients had improved outcomes. Significant differences between typical and atypical PA existed in PRA and ARR. Conclusions. NP-59 SPECT/CT may provide diagnostic potential in stage 1 hypertensive and atypical PA.

  5. Development of a screening tool for staging of diabetic retinopathy in fundus images

    Science.gov (United States)

    Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Bency, Mayur Joseph; Rangayyan, Rangaraj M.; Bansal, Reema; Gupta, Amod

    2015-03-01

    Diabetic retinopathy is a condition of the eye of diabetic patients where the retina is damaged because of long-term diabetes. The condition deteriorates towards irreversible blindness in extreme cases of diabetic retinopathy. Hence, early detection of diabetic retinopathy is important to prevent blindness. Regular screening of fundus images of diabetic patients could be helpful in preventing blindness caused by diabetic retinopathy. In this paper, we propose techniques for staging of diabetic retinopathy in fundus images using several shape and texture features computed from detected microaneurysms, exudates, and hemorrhages. The classification accuracy is reported in terms of the area (Az) under the receiver operating characteristic curve using 200 fundus images from the MESSIDOR database. The value of Az for classifying normal images versus mild, moderate, and severe nonproliferative diabetic retinopathy (NPDR) is 0:9106. The value of Az for classification of mild NPDR versus moderate and severe NPDR is 0:8372. The Az value for classification of moderate NPDR and severe NPDR is 0:9750.

  6. Effective System for Automatic Bundle Block Adjustment and Ortho Image Generation from Multi Sensor Satellite Imagery

    Science.gov (United States)

    Akilan, A.; Nagasubramanian, V.; Chaudhry, A.; Reddy, D. Rajesh; Sudheer Reddy, D.; Usha Devi, R.; Tirupati, T.; Radhadevi, P. V.; Varadan, G.

    2014-11-01

    Block Adjustment is a technique for large area mapping for images obtained from different remote sensingsatellites.The challenge in this process is to handle huge number of satellite imageries from different sources with different resolution and accuracies at the system level. This paper explains a system with various tools and techniques to effectively handle the end-to-end chain in large area mapping and production with good level of automation and the provisions for intuitive analysis of final results in 3D and 2D environment. In addition, the interface for using open source ortho and DEM references viz., ETM, SRTM etc. and displaying ESRI shapes for the image foot-prints are explained. Rigorous theory, mathematical modelling, workflow automation and sophisticated software engineering tools are included to ensure high photogrammetric accuracy and productivity. Major building blocks like Georeferencing, Geo-capturing and Geo-Modelling tools included in the block adjustment solution are explained in this paper. To provide optimal bundle block adjustment solution with high precision results, the system has been optimized in many stages to exploit the full utilization of hardware resources. The robustness of the system is ensured by handling failure in automatic procedure and saving the process state in every stage for subsequent restoration from the point of interruption. The results obtained from various stages of the system are presented in the paper.

  7. The stages of the international drug control system.

    Science.gov (United States)

    Carstairs, Catherine

    2005-01-01

    This paper argues that the history of the international drug control system of the League of Nations/United Nations can be divided into three cumulative stages. The first stage, the supply stage, dates back to early part of the 20th century, and aimed to reduce the supply of drugs through careful monitoring and trade regulations. This has remained the dominant control strategy. In the middle of the century, demand control, in the form of treatment and criminalization of the individual user, began to appear. This was the least successful stage. Finally, in the 1980s, the dangers of the drug traffic assumed an important place on the international agenda and measures to reduce drug-related organized crime were enacted. To date, this has been a process of proliferation of regulatory strategies. Recently, new challenges to the international drug control system have emerged, including well-funded non-governmental organizations critical of the war on drugs, and the adoption of harm reduction measures in national policies around the world.

  8. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Reinhard; Schaeffeler, Christoph; Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Kraus, Tobias M. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany); Berufsgenossenschaftliche Unfallklinik Tuebingen, Department of Trauma and Orthopaedics, Tuebingen (Germany); Torka, Sebastian [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany); Berufsgenossenschaftliche Unfallklinik Murnau, Department of Trauma and Orthopaedics, Murnau (Germany); Schlitter, Anna Melissa; Specht, Katja [Klinikum rechts der Isar, Technische Universitaet Muenchen, Institute of Pathology, Munich (Germany); Haller, Bernhard [Klinikum rechts der Isar, Technische Universitaet Muenchen, Institute of Medical Statistics and Epidemiology, Munich (Germany); Rechl, Hans [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany)

    2014-09-15

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53 % women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51 %) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49 %) cases were classified as ARCO stage 2. However, in all 37/37 (100 %) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P < 0.05). Histopathological analysis confirmed bone necrosis and subchondral fractures. In patients with AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. circle BME on MRI in AVN of femoral head indicates a subchondral fracture. (orig.)

  9. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head

    International Nuclear Information System (INIS)

    Meier, Reinhard; Schaeffeler, Christoph; Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus; Kraus, Tobias M.; Torka, Sebastian; Schlitter, Anna Melissa; Specht, Katja; Haller, Bernhard; Rechl, Hans

    2014-01-01

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53 % women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51 %) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49 %) cases were classified as ARCO stage 2. However, in all 37/37 (100 %) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P < 0.05). Histopathological analysis confirmed bone necrosis and subchondral fractures. In patients with AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. circle BME on MRI in AVN of femoral head indicates a subchondral fracture. (orig.)

  10. Intestinal diffuse large B-cell lymphoma: an evaluation of different staging systems.

    Science.gov (United States)

    Hwang, Hee Sang; Yoon, Dok Hyun; Suh, Cheolwon; Park, Chan-Sik; Huh, Jooryung

    2014-01-01

    The gastrointestinal tract is the most common primary extranodal site for diffuse large B-cell lymphoma (DLBCL). However, there is no consensus on the most appropriate staging system for intestinal DLBCL. We evaluated the utility of the modified Ann Arbor system, the Lugano system, and the Paris staging system (a modification of the Tumor, Node, Metastases [TNM] staging for epithelial tumors) in 66 cases of resected intestinal DLBCL. The cases were treated with surgery, plus either cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) chemotherapy alone (n=26) or with the addition of rituximab immunotherapy (n=40). Median follow-up time was 40.4 months (range, 2.1-171.6 months). Fifty-six patients (84.8%) achieved complete remission. The overall 5-yr survival rate was 86.4% (57/66). Of the stage categories defined for each staging system, only the T stage of the Paris classification showed prognostic significance for overall survival by univariate analysis. However, none of the stage parameters was significantly correlated with patient survival on multivariate analysis. In conclusion, the results suggest that the T stage of the Paris classification system may be a prognostic indicator in intestinal DLBCL. The results also imply that in surgically resected intestinal DLBCL, the addition of rituximab to the CHOP regimen does not confer significant survival advantage.

  11. Multi-stage 3D-2D registration for correction of anatomical deformation in image-guided spine surgery

    Science.gov (United States)

    Ketcha, M. D.; De Silva, T.; Uneri, A.; Jacobson, M. W.; Goerres, J.; Kleinszig, G.; Vogt, S.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2017-06-01

    A multi-stage image-based 3D-2D registration method is presented that maps annotations in a 3D image (e.g. point labels annotating individual vertebrae in preoperative CT) to an intraoperative radiograph in which the patient has undergone non-rigid anatomical deformation due to changes in patient positioning or due to the intervention itself. The proposed method (termed msLevelCheck) extends a previous rigid registration solution (LevelCheck) to provide an accurate mapping of vertebral labels in the presence of spinal deformation. The method employs a multi-stage series of rigid 3D-2D registrations performed on sets of automatically determined and increasingly localized sub-images, with the final stage achieving a rigid mapping for each label to yield a locally rigid yet globally deformable solution. The method was evaluated first in a phantom study in which a CT image of the spine was acquired followed by a series of 7 mobile radiographs with increasing degree of deformation applied. Second, the method was validated using a clinical data set of patients exhibiting strong spinal deformation during thoracolumbar spine surgery. Registration accuracy was assessed using projection distance error (PDE) and failure rate (PDE  >  20 mm—i.e. label registered outside vertebra). The msLevelCheck method was able to register all vertebrae accurately for all cases of deformation in the phantom study, improving the maximum PDE of the rigid method from 22.4 mm to 3.9 mm. The clinical study demonstrated the feasibility of the approach in real patient data by accurately registering all vertebral labels in each case, eliminating all instances of failure encountered in the conventional rigid method. The multi-stage approach demonstrated accurate mapping of vertebral labels in the presence of strong spinal deformation. The msLevelCheck method maintains other advantageous aspects of the original LevelCheck method (e.g. compatibility with standard clinical workflow, large

  12. A new computerized moving stage for optical microscopes

    Science.gov (United States)

    Hatiboglu, Can Ulas; Akin, Serhat

    2004-06-01

    Measurements of microscope stage movements in the x and y directions are of importance for some stereological methods. Traditionally, the length of stage movements is measured with differing precision and accuracy using a suitable motorized stage, a microscope and software. Such equipment is generally expensive and not readily available in many laboratories. One other challenging problem is the adaptability to available microscope systems which weakens the possibility of the equipment to be used with any kind of light microscope. This paper describes a simple and cheap programmable moving stage that can be used with the available microscopes in the market. The movements of the stage are controlled by two servo-motors and a controller chip via a Java-based image processing software. With the developed motorized stage and a microscope equipped with a CCD camera, the software allows complete coverage of the specimens with minimum overlap, eliminating the optical strain associated with counting hundreds of images through an eyepiece, in a quick and precise fashion. The uses and the accuracy of the developed stage are demonstrated using thin sections obtained from a limestone core plug.

  13. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  14. Staging of cervical endometrial carcinoma using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Vela, A. C.; Oleaga, L.; Cura del, J. L.; Grande, J.; Grande, D.

    1999-01-01

    To demonstrate the benefits of magnetic resonance imaging (MRI) for the staging of endometrial carcinoma and to compare the results of the spin echo (SE) sequence in T2 with the results of the pos gadolinium intravenous study. We have studied 51 women diagnosed with endometrial carcinoma by means of a D and C and confirmed surgically using T1 equipment. All of them have had SE T1 axial sequences, SE in protonic density (PD) and T'' on an axial and sagittal plane carried out on them and 32 cases were studied after the administration of gadolinium intravenously (i. V.). We have valued the depth of the myometrial infiltration and the cervical invasion. The positive predictive value (PPV) and the negative predictive value (VPV) of the MRI to value the deep infiltration of the endometrium were 87.9% and 77.8% respectively. In the 32 cases where we administered gadolinium we obtained a PPV of 90% and a NPV of 83.8%, in both the SE T2 study and the contrast study. In the diagnosis of the cervical invasion we have obtained PPV and NPV values of 75% and 88.1% respectively. In the group of the 32 cases that had the contrast agent administered, we have obtained the same results in both the series: PPV of 80% and NPV of 85.2%. We have found a high correlation index between the staging using MRI and pathological anatomy, especially in stages I and II of the IFGO (International Federation of Gynecology and Obstretics) classification. The use of gadolinium has not varied the results obtained with the SE T2 series. (Author) 18 refs

  15. New image-stabilizing system

    Science.gov (United States)

    Zhao, Yuejin

    1996-06-01

    In this paper, a new method for image stabilization with a three-axis image- stabilizing reflecting prism assembly is presented, and the principle of image stabilization in this prism assembly, formulae for image stabilization and working formulae with an approximation up to the third power are given in detail. In this image-stabilizing system, a single chip microcomputer is used to calculate value of compensating angles and thus to control the prism assembly. Two gyroscopes act as sensors from which information of angular perturbation is obtained, three stepping motors drive the prism assembly to compensate for the movement of image produced by angular perturbation. The image-stabilizing device so established is a multifold system which involves optics, mechanics, electronics and computer.

  16. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  17. Comparison of the diagnostic value of MR imaging and ophthalmoscopy for the staging of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Aman; Wan, Wenshuai; Yeom, Kristen [Stanford University, Department of Radiology, Stanford, CA (United States); Eisenhut, Christina A. [Technical University of Munich, Department of Radiology, Munich (Germany); Ebrahimi, Katayoon B. [Johns Hopkins University, Department of Ocular Oncology, Baltimore, MD (United States); Patel, Chirag [University of California Davis, Department of Radiology, Davis, CA (United States); O' Brien, Joan M. [University of Pennsylvania, Department of Ophthalmology, Philadelphia, PA (United States); Daldrup-Link, Heike E. [Stanford University, Department of Radiology, Stanford, CA (United States); Stanford University, Department of Radiology, Pediatric Radiology Section, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2013-05-15

    To compare the diagnostic value of magnetic resonance (MR) imaging and ophthalmoscopy for staging of retinoblastoma. MR and ophthalmoscopic images of 36 patients who underwent enucleation were evaluated retrospectively following institutional review board approval. Histopathology being the standard of reference, the sensitivity and specificity of both diagnostic modalities were compared regarding growth pattern, iris neoangiogenesis, retinal detachment, vitreous seeds and optic nerve invasion. Data were analysed via McNemar's test. Both investigations showed no significant difference in accuracy for the detection of different tumour growth patterns (P = 0.80). Vitreous seeding detection was superior by ophthalmoscopy (P < 0.001). For prelaminar optic nerve invasion, MR imaging showed similar sensitivity as ophthalmoscopy but increased specificity of 40 % (CI 0.12-0.74) vs. 20 % (0.03-0.56). MR detected optic nerve involvement past the lamina cribrosa with a sensitivity of 80 % (0.28-0.99) and a specificity of 74 % (0.55-0.88). The absence of optic nerve enhancement excluded histopathological infiltration, but the presence of optic nerve enhancement included a high number of false positives (22-24 %). Ophthalmoscopy remains the method of choice for determining extent within the globe while MR imaging is useful for evaluating extraocular tumour extension. Thus, both have their own strengths and contribute uniquely to the staging of retinoblastoma. (orig.)

  18. End-Stage Renal Disease Prospective Payment System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This final rule implements a case-mix adjusted bundled prospective payment system (PPS) for Medicare outpatient end-stage renal disease (ESRD) dialysis facilities...

  19. Staging of endometrial cancer with MRI: Guidelines of the European Society of Urogenital Imaging

    International Nuclear Information System (INIS)

    Kinkel, K.; Forstner, R.; Danza, F.M.; Oleaga, L.; Cunha, T.M.; Bergman, A.; Barentsz, J.O.; Balleyguier, C.; Brkljacic, B.; Spencer, J.A.

    2009-01-01

    The purpose of this study was to define guidelines for endometrial cancer staging with MRI. The technique included critical review and expert consensus of MRI protocols by the female imaging subcommittee of the European Society of Urogenital Radiology, from ten European institutions, and published literature between 1999 and 2008. The results indicated that high field MRI should include at least two T2-weighted sequences in sagittal, axial oblique or coronal oblique orientation (short and long axis of the uterine body) of the pelvic content. High-resolution post-contrast images acquired at 2 min ± 30 s after intravenous contrast injection are suggested to be optimal for the diagnosis of myometrial invasion. If cervical invasion is suspected, additional slice orientation perpendicular to the axis of the endocervical channel is recommended. Due to the limited sensitivity of MRI to detect lymph node metastasis without lymph node-specific contrast agents, retroperitoneal lymph node screening with pre-contrast sequences up to the level of the kidneys is optional. The likelihood of lymph node invasion and the need for staging lymphadenectomy are also indicated by high-grade histology at endometrial tissue sampling and by deep myometrial or cervical invasion detected by MRI. In conclusion, expert consensus and literature review lead to an optimized MRI protocol to stage endometrial cancer. (orig.)

  20. Army medical imaging system: ARMIS

    International Nuclear Information System (INIS)

    Siedband, M.P.; Kramp, D.C.

    1987-01-01

    Recent advances of stimulable phosphor screens, data cards using optical storage means, and new personal computers with image processing capability have made possible the design of economical filmless medical imaging systems. The addition of communication links means that remote interpretation of images is also possible. The Army Medical Imaging System uses stimulable phosphor screens, digital readout, a small computer, an optical digital data card device, and a DIN/PACS link. Up to 200 images can be stored in the computer hard disk for rapid recall and reading by the radiologist. The computer permits image processing, annotation, insertion of text, and control of the system. Each device contains an image storage RAM and communicates with the computer via the small computer systems interface. Data compression is used to reduce the required storage capacity and transmission times of the 1-mB images. The credit card-size optical data cards replace film and can store 12 or more images. The data cards can be read on an independent viewer. The research is supported by the U.S. Army Biomedical Research and Development Laboratory

  1. Analysis of multi-stage open shop processing systems

    NARCIS (Netherlands)

    Eggermont, C.E.J.; Schrijver, A.; Woeginger, G.J.; Schwentick, T.; Dürr, C.

    2011-01-01

    We study algorithmic problems in multi-stage open shop processing systems that are centered around reachability and deadlock detection questions. We characterize safe and unsafe system states. We show that it is easy to recognize system states that can be reached from the initial state (where the

  2. Design of low noise imaging system

    Science.gov (United States)

    Hu, Bo; Chen, Xiaolai

    2017-10-01

    In order to meet the needs of engineering applications for low noise imaging system under the mode of global shutter, a complete imaging system is designed based on the SCMOS (Scientific CMOS) image sensor CIS2521F. The paper introduces hardware circuit and software system design. Based on the analysis of key indexes and technologies about the imaging system, the paper makes chips selection and decides SCMOS + FPGA+ DDRII+ Camera Link as processing architecture. Then it introduces the entire system workflow and power supply and distribution unit design. As for the software system, which consists of the SCMOS control module, image acquisition module, data cache control module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The imaging experimental results show that the imaging system exhibits a 2560*2160 pixel resolution, has a maximum frame frequency of 50 fps. The imaging quality of the system satisfies the requirement of the index.

  3. The global stability of a delayed predator-prey system with two stage-structure

    International Nuclear Information System (INIS)

    Wang Fengyan; Pang Guoping

    2009-01-01

    Based on the classical delayed stage-structured model and Lotka-Volterra predator-prey model, we introduce and study a delayed predator-prey system, where prey and predator have two stages, an immature stage and a mature stage. The time delays are the time lengths between the immature's birth and maturity of prey and predator species. Results on global asymptotic stability of nonnegative equilibria of the delay system are given, which generalize and suggest that good continuity exists between the predator-prey system and its corresponding stage-structured system.

  4. Artificial intelligence and medical imaging. Expert systems and image analysis

    International Nuclear Information System (INIS)

    Wackenheim, A.; Zoellner, G.; Horviller, S.; Jacqmain, T.

    1987-01-01

    This paper gives an overview on the existing systems for automated image analysis and interpretation in medical imaging, especially in radiology. The example of ORFEVRE, the system for the analysis of CAT-scan images of the cervical triplet (c3-c5) by image analysis and subsequent expert-system is given and discussed in detail. Possible extensions are described [fr

  5. Preliminary results of endorectal surface coil magnetic resonance imaging for local staging of prostate cancer

    NARCIS (Netherlands)

    Jager, G. J.; Barentsz, J. O.; de la Rosette, J. J.; Rosenbusch, G.

    1994-01-01

    To evaluate the effectiveness of endorectal surface coil (ERC) magnetic resonance imaging (MRI) in the local staging of adenocarcinoma of the prostate (ACP). A total of 23 patients who were considered candidates for radical prostatectomy because of clinically localized ACP were examined by ERC-MRI.

  6. Highly integrated image sensors enable low-cost imaging systems

    Science.gov (United States)

    Gallagher, Paul K.; Lake, Don; Chalmers, David; Hurwitz, J. E. D.

    1997-09-01

    The highest barriers to wide scale implementation of vision systems have been cost. This is closely followed by the level of difficulty of putting a complete imaging system together. As anyone who has every been in the position of creating a vision system knows, the various bits and pieces supplied by the many vendors are not under any type of standardization control. In short, unless you are an expert in imaging, electrical interfacing, computers, digital signal processing, and high speed storage techniques, you will likely spend more money trying to do it yourself rather than to buy the exceedingly expensive systems available. Another alternative is making headway into the imaging market however. The growing investment in highly integrated CMOS based imagers is addressing both the cost and the system integration difficulties. This paper discusses the benefits gained from CMOS based imaging, and how these benefits are already being applied.

  7. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  8. Semiautomated analysis of embryoscope images: Using localized variance of image intensity to detect embryo developmental stages.

    Science.gov (United States)

    Mölder, Anna; Drury, Sarah; Costen, Nicholas; Hartshorne, Geraldine M; Czanner, Silvester

    2015-02-01

    Embryo selection in in vitro fertilization (IVF) treatment has traditionally been done manually using microscopy at intermittent time points during embryo development. Novel technique has made it possible to monitor embryos using time lapse for long periods of time and together with the reduced cost of data storage, this has opened the door to long-term time-lapse monitoring, and large amounts of image material is now routinely gathered. However, the analysis is still to a large extent performed manually, and images are mostly used as qualitative reference. To make full use of the increased amount of microscopic image material, (semi)automated computer-aided tools are needed. An additional benefit of automation is the establishment of standardization tools for embryo selection and transfer, making decisions more transparent and less subjective. Another is the possibility to gather and analyze data in a high-throughput manner, gathering data from multiple clinics and increasing our knowledge of early human embryo development. In this study, the extraction of data to automatically select and track spatio-temporal events and features from sets of embryo images has been achieved using localized variance based on the distribution of image grey scale levels. A retrospective cohort study was performed using time-lapse imaging data derived from 39 human embryos from seven couples, covering the time from fertilization up to 6.3 days. The profile of localized variance has been used to characterize syngamy, mitotic division and stages of cleavage, compaction, and blastocoel formation. Prior to analysis, focal plane and embryo location were automatically detected, limiting precomputational user interaction to a calibration step and usable for automatic detection of region of interest (ROI) regardless of the method of analysis. The results were validated against the opinion of clinical experts. © 2015 International Society for Advancement of Cytometry. © 2015 International

  9. Protocol images for staging of gastric cancer in radiology Hospital San Vicente de Paul

    International Nuclear Information System (INIS)

    Jarquin Salvatierra, Estibaliz

    2010-01-01

    The realization of a protocol for the evaluation of imaging in the radiology service of Hospital San Vicente de Paul in the province of Heredia is considered a useful tool that allows a clear and simple communication with the rest of the interdisciplinary team that serves patients with gastric cancer. The adequate management of this disease is important for an assessment and standardized reporting of images to facilitate preoperative planning; because the number of diagnostic studies that should be performed for the detection once obtained the histological diagnosis to establish the staging. Prior knowledge of stage according to TNM (Tumor/Nodes/Metastasis) classification is essential. The initial assessment for radiological detection of gastric cancer was performed with gastroduodenal series with double contrast medium and fluoroscopic control. The establishment of a study effects required for routine is important and avoid underdiagnosis.The new Hospital San Vicente de Paul will have the tomographic assessment and trans abdominal ultrasound (USTA) essential to assess the presence of metastasis to peritoneum and solid organs, in addition to the adenomegaly suggesting neoplastic infiltration. (author) [es

  10. [Comparison of differentiated thyroid carcinoma staging systems in a Spanish population].

    Science.gov (United States)

    Andía Melero, Víctor Manuel; Martín de Santa-Olalla Llanes, María; Sambo Salas, Marcel; Percovich Hualpa, Juan Carlos; Motilla de la Cámara, Marta; Collado Yurrita, Luis

    2015-04-01

    Differentiated thyroid carcinoma staging is increasingly important due to the current trends to a less intensive therapy in low-risk patients. The TNM system is most widely used, but other systems based on follow-up of several patient cohorts have been developed. When these systems have been applied to other populations, results have been discordant. Our study evaluates the suitability of several differentiated thyroid carcinoma staging systems in a Spanish population. 729 patients with differentiated thyroid carcinoma and staging data available were enrolled. Mean follow-up time was 10.8 years. The TNM, EORTC, AMES, Clinical class, MACIS, Ohio, NTCTCS, and Spanish systems were applied to all histological types. The Kaplan-Meier survival curves for each system were analyzed, and compared using the proportion of explained variation (PEV). The demographic and clinical characteristics of our population were similar to those of other Spanish and international cohorts reported. The best systems were NTCTCS, with 74.7% PEV, and TNM (68.3%), followed by the Ohio, MACIS, EORTC, and AMES systems with minimal differences between them, while the least adequate were the Spanish (55.2%) and Clinical class (47.1%) systems. The NTCTCS staging system was found to be better than TNM in our population but, because of its simplicity and greater dissemination, the TNM appears to be recommended for staging of patients with differentiated thyroid carcinoma. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  11. Imaging system

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.

    1987-01-01

    A moving object such as a container on a conveyor belt is imaged by an optical system onto a charge coupled device array in which the lines of the array are arranged perpendicular to the direction of motion of the object. The speed of movement of the object is sensed to generate electrical signals which are processed to provide shift signals enabling the shifting of data row to row in the array in synchronism with the movement of the container. The electrical charge associated with a given point on the array is transferred from one line to the other until it appears at the last line of the array, from which it is read out in known manner in conjunction with all other electrical charges associated with the row of charge coupled devices in the last line of the array. Due to the integrating effect achieved, the aperture of the imaging system can be much smaller than otherwise would be required, and/or the level of light illumination can be reduced. The imaging system can be applied to X-ray inspection devices, aerial surveillance or scanning of moving documents in copying processes. (author)

  12. Handheld microwave bomb-detecting imaging system

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo

    2017-05-01

    Proposed novel imaging technique will provide all weather high-resolution imaging and recognition capability for RF/Microwave signals with good penetration through highly scattered media: fog, snow, dust, smoke, even foliage, camouflage, walls and ground. Image resolution in proposed imaging system is not limited by diffraction and will be determined by processor and sampling frequency. Proposed imaging system can simultaneously cover wide field of view, detect multiple targets and can be multi-frequency, multi-function. Directional antennas in imaging system can be close positioned and installed in cell phone size handheld device, on small aircraft or distributed around protected border or object. Non-scanning monopulse system allows dramatically decrease in transmitting power and at the same time provides increased imaging range by integrating 2-3 orders more signals than regular scanning imaging systems.

  13. Staging N0 Oral Cancer: Lymphoscintigraphy and Conventional Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, J.B.; Soerensen, J.A.; Grupe, P.; Karstoft, J.; Krogdahl, A. [Odense Univ. Hospital (Denmark). Depts. of Plastic and Reconstructive Surgery, Nuclear Medicine, Radiology, and Pathology

    2005-08-01

    PURPOSE: To compare sentinel lymph node biopsy, magnetic resonance imaging (MRI), Doppler ultrasonography, and palpation as staging tools in patients with T1/T2 N0 cancer of the oral cavity. MATERIAL AND METHODS: Forty consecutive patients were enrolled (17 F and 23 M, aged 32-90 years), 24 T1 and 16 T2 cN0 squamous cell carcinoma of the oral cavity. Palpation was carried out by two observers prior to inclusion. MRI, gray-scale and Doppler ultrasonography were performed. Lymphoscintigraphies were done after peritumoral injections of 99mTc labelled rheniumsulphide nanocolloid, followed by sentinel lymph node biopsy guided by a gamma probe and Patent Blue. Palpation, Doppler ultrasonography, MRI, and sentinel lymph node biopsy were compared to a combination of histopathology and follow-up. Diagnostic testing was performed using the x2 test. RESULTS: Histopathological examination revealed metastatic spread to the neck in 14 of 40 patients. One patient had bilateral neck disease. Sentinel lymph node biopsy and ultrasonography were performed in 80 neck sides of 40 patients and MRI in 70 neck sides (5 patients were claustrophobic). SN revealed suspicious lymph nodes in 12 necks, ultrasonography in 23 necks, and MRI in 9 necks. The positive predictive value of sentinel lymph node biopsy was 100%, ultrasonography 57%, and MRI 56%. The respective negative predictive values were 96%, 96%, and 85%. The sensitivity of sentinel lymph node biopsy 80% was comparable to ultrasonography 87%, but the sensitivity of MRI 36% was low. The specificities were 100%, 85%, and 93%, respectively. By combined sentinel lymph node biopsy and ultrasonography the overall sensitivity could have been 100%. CONCLUSION: Sentinel lymph node biopsy improved staging of patients with small N0 oral cancers. Combined sentinel lymph node biopsy and Doppler ultrasonography may further improve staging. MRI and simple palpation results were poor.

  14. Enhancement MRI evaluation of neuroblastoma staging in children

    International Nuclear Information System (INIS)

    Li Xin; Wang Chunxiang; Zhao Bin; Liu Peifang

    2002-01-01

    Objective: To evaluate the value and limitation of Gd-DTPA enhanced MRI for neuroblastoma staging in children. Methods: Twelve cases of neuroblastoma proved by operation or bone marrow aspiration were examined by gadolinium-enhanced MRI. The age ranged from seven months to five years, mean 3.7 years. Eight tumors originated from adrenal, and four from posterior mediastinum. Conventional sequences, double dose gadolinium-enhanced MRI, and 3D CEMRA were used in all patients. Six cases were examined by CT in same time. Imaging staging on surgic-histopathological-based International Neuroblastoma Staging System (INSS) was performed. Results: Six patients were staged by CT, including stage I-II in 2 cases, stage III in 4 cases, and stage IV in none. Twelve patients were staged by conventional MRI, including stage I-II in 2 cases, stage III in 9 cases, and stage IV in 1 case. Twelve patients were staged by double dose gadolinium-enhanced MRI, including stage I-II in 1 case, stage III in 1 case, and stage IV in 10 cases. Conclusion: Gadolinium-enhanced MRI was a single best imaging modality for neuroblastoma, most useful for distal to diaphragm metastasis, dumbbell tumor intraspinal extension, and bone marrow metastasis that was not detected by aspirate examination. Enhancement MRI was important in evaluating the therapy and was also helpful in assessing the therapeutic efficacy and relapse. 3D CEMRA helps demonstrate large vascular encasement and tumor erosion into important organs, and it is useful in assessing the respectability. Long examination time and lack in showing the characteristic calcium were the limitations

  15. The interrater and intrarater reliability of the Philpott-Javer staging system based on level of training.

    Science.gov (United States)

    Parhar, Harman S; Thamboo, Andrew; Habib, Al-Rahim; Chang, Brent; Gan, Eng Cern; Javer, Amin R

    2014-04-01

    The Philpott-Javer postoperative endoscopic mucosal staging system for allergic fungal rhinosinusitis has previously demonstrated acceptable interrater reliability among rhinologists. There are, however, numerous learners involved in patient care at tertiary centers. This study aims to analyze the interrater and intrarater reliability of this system among learners in otolaryngology at different stages in training. A prospective analysis of retrospectively collected endoscopic photographs. A tertiary care teaching hospital (January 2013). Fifty patients undergoing routine follow-up. Three photographs from each of 50 patients undergoing routine postsurgical nasoendoscopy were reviewed. Images were played twice, 1 week apart, in 2 differently randomized cycles and scored according to Philpott-Javer criteria by a rhinologist, a rhinology fellow, a senior otolaryngology resident, a junior otolaryngology resident, and a medical student. Interobserver reliability was assessed using the intraclass correlation coefficient, while intrarater reliability was assessed by Shrout-Fleiss κ values. Agreement between each learner and the rhinologist was also assessed using κ values. The interclass correlation among the 5 raters was 0.7600 (95% confidence interval, 0.6917-0.8161) for the Philpott-Javer scoring system, suggesting substantial reliability. Intrarater data showed substantial to almost-perfect reliability (κ values between 0.668 and 0.815) among all raters using this system. There was also moderate to substantial agreement between the learners and the rhinologist (κ values between 0.534 and 0.710). Results suggest that the Philpott-Javer staging system has acceptable intrarater and interrater reliability among learners of differing levels of clinical experience and is suitable for evaluating progress following surgery.

  16. Intelligent Image Recognition System for Marine Fouling Using Softmax Transfer Learning and Deep Convolutional Neural Networks

    Directory of Open Access Journals (Sweden)

    C. S. Chin

    2017-01-01

    Full Text Available The control of biofouling on marine vessels is challenging and costly. Early detection before hull performance is significantly affected is desirable, especially if “grooming” is an option. Here, a system is described to detect marine fouling at an early stage of development. In this study, an image of fouling can be transferred wirelessly via a mobile network for analysis. The proposed system utilizes transfer learning and deep convolutional neural network (CNN to perform image recognition on the fouling image by classifying the detected fouling species and the density of fouling on the surface. Transfer learning using Google’s Inception V3 model with Softmax at last layer was carried out on a fouling database of 10 categories and 1825 images. Experimental results gave acceptable accuracies for fouling detection and recognition.

  17. Contrast-enhanced dynamic and diffusion-weighted magnetic resonance imaging at 3.0 T to assess early-stage nasopharyngeal carcinoma.

    Science.gov (United States)

    Ni, Liangping; Liu, Ying

    2018-04-01

    The present study aimed to assess early-stage nasopharyngeal carcinoma (NPC) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) at 3.0 T. A total of 44 patients newly diagnosed with NPC were included in the present study. All patients underwent MR examination at 3.0 T using DCE-MRI and DWI. The volume transfer constant ( K trans ), flux rate constant between extravascular extracellular space and plasma ( K ep ), the volume of extravascular extracellular space per unit volume of tissue ( V e ) and the apparent diffusion coefficient (ADC) of tumours were investigated. Furthermore, the correlation between clinical stages and ADC value and K trans were analysed. The diagnostic accuracy of K trans and ADC were estimated using receiver operating characteristic curves. NPC stage correlated positively with K trans and negatively with ADC values. Additionally, tumour K trans negatively correlated with ADC value. The sensitivity and accuracy of combined K trans and ADC in distinguishing between stage II and stage III and stage III and IV were higher than the values of either measurement used separately. The present study suggested that K trans and ADC derived from DCE-MRI and DWI may be useful to detect stage early NPC accurately. K trans and ADC in combination were superior than either alone.

  18. Proposal for a new staging system for osteoradionecrosis of the mandible

    NARCIS (Netherlands)

    Karagozoglu, K.H.; Dekker, H.; Rietveld, D.H.F.; de Bree, R.; Schulten, E.A.J.M.; Kantola, S.; Forouzanfar, T.; van der Waal, I.

    2014-01-01

    The presented staging system seems well reproducible, facilitating the comparison of study groups dealing with the various issues of osteoradionecrosis of the mandible. It is yet to be evaluated whether the presently proposed staging system is useful for management purposes.

  19. SU-E-J-128: Two-Stage Atlas Selection in Multi-Atlas-Based Image Segmentation

    International Nuclear Information System (INIS)

    Zhao, T; Ruan, D

    2015-01-01

    Purpose: In the new era of big data, multi-atlas-based image segmentation is challenged by heterogeneous atlas quality and high computation burden from extensive atlas collection, demanding efficient identification of the most relevant atlases. This study aims to develop a two-stage atlas selection scheme to achieve computational economy with performance guarantee. Methods: We develop a low-cost fusion set selection scheme by introducing a preliminary selection to trim full atlas collection into an augmented subset, alleviating the need for extensive full-fledged registrations. More specifically, fusion set selection is performed in two successive steps: preliminary selection and refinement. An augmented subset is first roughly selected from the whole atlas collection with a simple registration scheme and the corresponding preliminary relevance metric; the augmented subset is further refined into the desired fusion set size, using full-fledged registration and the associated relevance metric. The main novelty of this work is the introduction of an inference model to relate the preliminary and refined relevance metrics, based on which the augmented subset size is rigorously derived to ensure the desired atlases survive the preliminary selection with high probability. Results: The performance and complexity of the proposed two-stage atlas selection method were assessed using a collection of 30 prostate MR images. It achieved comparable segmentation accuracy as the conventional one-stage method with full-fledged registration, but significantly reduced computation time to 1/3 (from 30.82 to 11.04 min per segmentation). Compared with alternative one-stage cost-saving approach, the proposed scheme yielded superior performance with mean and medium DSC of (0.83, 0.85) compared to (0.74, 0.78). Conclusion: This work has developed a model-guided two-stage atlas selection scheme to achieve significant cost reduction while guaranteeing high segmentation accuracy. The benefit

  20. SLS Block 1-B and Exploration Upper Stage Navigation System Design

    Science.gov (United States)

    Oliver, T. Emerson; Park, Thomas B.; Smith, Austin; Anzalone, Evan; Bernard, Bill; Strickland, Dennis; Geohagan, Kevin; Green, Melissa; Leggett, Jarred

    2018-01-01

    The SLS Block 1B vehicle is planned to extend NASA's heavy lift capability beyond the initial SLS Block 1 vehicle. The most noticeable change for this vehicle from SLS Block 1 is the swapping of the upper stage from the Interim Cryogenic Propulsion stage (ICPS), a modified Delta IV upper stage, to the more capable Exploration Upper Stage (EUS). As the vehicle evolves to provide greater lift capability and execute more demanding missions so must the SLS Integrated Navigation System to support those missions. The SLS Block 1 vehicle carries two independent navigation systems. The responsibility of the two systems is delineated between ascent and upper stage flight. The Block 1 navigation system is responsible for the phase of flight between the launch pad and insertion into Low-Earth Orbit (LEO). The upper stage system assumes the mission from LEO to payload separation. For the Block 1B vehicle, the two functions are combined into a single system intended to navigate from ground to payload insertion. Both are responsible for self-disposal once payload delivery is achieved. The evolution of the navigation hardware and algorithms from an inertial-only navigation system for Block 1 ascent flight to a tightly coupled GPS-aided inertial navigation system for Block 1-B is described. The Block 1 GN&C system has been designed to meet a LEO insertion target with a specified accuracy. The Block 1-B vehicle navigation system is designed to support the Block 1 LEO target accuracy as well as trans-lunar or trans-planetary injection accuracy. This is measured in terms of payload impact and stage disposal requirements. Additionally, the Block 1-B vehicle is designed to support human exploration and thus is designed to minimize the probability of Loss of Crew (LOC) through high-quality inertial instruments and Fault Detection, Isolation, and Recovery (FDIR) logic. The preliminary Block 1B integrated navigation system design is presented along with the challenges associated with

  1. IDAPS (Image Data Automated Processing System) System Description

    Science.gov (United States)

    1988-06-24

    This document describes the physical configuration and components used in the image processing system referred to as IDAPS (Image Data Automated ... Processing System). This system was developed by the Environmental Research Institute of Michigan (ERIM) for Eglin Air Force Base. The system is designed

  2. A Lymph Node Staging System for Gastric Cancer: A Hybrid Type Based on Topographic and Numeric Systems.

    Directory of Open Access Journals (Sweden)

    Yoon Young Choi

    Full Text Available Although changing a lymph node staging system from an anatomically based system to a numerically based system in gastric cancer offers better prognostic performance, several problems can arise: it does not offer information on the anatomical extent of disease and cannot represent the extent of lymph node dissection. The purpose of this study was to discover an alternative lymph node staging system for gastric cancer. Data from 6025 patients who underwent gastrectomy for primary gastric cancer between January 2000 and December 2010 were reviewed. The lymph node groups were reclassified into lesser-curvature, greater-curvature, and extra-perigastric groups. Presence of any metastatic lymph node in one group was considered positive. Lymph node groups were further stratified into four (new N0-new N3 according to the number of positive lymph node groups. Survival outcomes with this new N staging were compared with those of the current TNM system. For validation, two centers in Japan (large center, n = 3443; medium center, n = 560 were invited. Even among the same pN stages, the more advanced new N stage showed worse prognosis, indicating that the anatomical extent of metastatic lymph nodes is important. The prognostic performance of the new staging system was as good as that of the current TNM system for overall advanced gastric cancer as well as lymph node-positive gastric cancer (Harrell C-index was 0.799, 0.726, and 0.703 in current TNM and 0.799, 0.727, and 0.703 in new TNM stage. Validation sets supported these outcomes. The new N staging system demonstrated prognostic performance equal to that of the current TNM system and could thus be used as an alternative.

  3. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.; Tsui, B.

    1981-01-01

    A general computer code to simulate the imaging properties of existing and hypothetical imaging systems viewing realistic source distributions within non-uniform media. Such a code allows comparative evaluations of existing and hypothetical systems, and optimization of critical parameters of system design by maximizing the signal-to-noise ratio. To be most useful, such a code allows simulation of conventional scintillation scanners and cameras as well as single-photon and position tomographic systems

  4. Analysis of image plane's Illumination in Image-forming System

    International Nuclear Information System (INIS)

    Duan Lihua; Zeng Yan'an; Zhang Nanyangsheng; Wang Zhiguo; Yin Shiliang

    2011-01-01

    In the detection of optical radiation, the detecting accuracy is affected by optic power distribution of the detector's surface to a large extent. In addition, in the image-forming system, the quality of the image is greatly determined by the uniformity of the image's illumination distribution. However, in the practical optical system, affected by the factors such as field of view, false light and off axis and so on, the distribution of the image's illumination tends to be non uniform, so it is necessary to discuss the image plane's illumination in image-forming systems. In order to analyze the characteristics of the image-forming system at a full range, on the basis of photometry, the formulas to calculate the illumination of the imaging plane have been summarized by the numbers. Moreover, the relationship between the horizontal offset of the light source and the illumination of the image has been discussed in detail. After that, the influence of some key factors such as aperture angle, off-axis distance and horizontal offset on illumination of the image has been brought forward. Through numerical simulation, various theoretical curves of those key factors have been given. The results of the numerical simulation show that it is recommended to aggrandize the diameter of the exit pupil to increase the illumination of the image. The angle of view plays a negative role in the illumination distribution of the image, that is, the uniformity of the illumination distribution can be enhanced by compressing the angle of view. Lastly, it is proved that telecentric optical design is an effective way to advance the uniformity of the illumination distribution.

  5. Quantitative luminescence imaging system

    Science.gov (United States)

    Erwin, David N.; Kiel, Johnathan L.; Batishko, Charles R.; Stahl, Kurt A.

    1990-01-01

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopie imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber.

  6. Primary staging of laryngeal and hypopharyngeal cancer: CT, MR imaging and dual-energy CT

    International Nuclear Information System (INIS)

    Kuno, Hirofumi; Onaya, Hiroaki; Fujii, Satoshi; Ojiri, Hiroya; Otani, Katharina; Satake, Mitsuo

    2014-01-01

    Laryngeal and hypopharyngeal cancer, in particular T4a disease associated with cartilage invasion and extralaryngeal spread, needs to be evaluated accurately because treatment can impact heavily on a patient's quality of life. Reliable imaging tools are therefore indispensible. CT offers high spatial and temporal resolution and remains the preferred imaging modality. Although cartilage invasion can be diagnosed with acceptable accuracy by applying defined criteria for combinations of erosion, lysis and transmural extralaryngeal spread, iodine-enhanced tumors and non-ossified cartilage are sometimes difficult to distinguish. MR offers high contrast resolution for images without motion artifacts, although inflammatory changes in cartilage sometimes resemble cartilage invasion. With dual-energy CT, combined iodine overlay images and weighted average images can be used for evaluation of cartilage invasion, since iodine enhancement is evident in tumor tissue but not in cartilage. Extralaryngeal spread can be evaluated from CT, MR or dual-energy CT images and the routes of tumor spread into the extralaryngeal soft tissue must be considered; (1) via the thyrohyoid membrane along the superior laryngeal neurovascular bundle, (2) via the inferior pharyngeal constrictor muscle, and (3) via the cricothyroid membrane. Radiologists need to understand the advantages and limitations of each imaging modality for staging of laryngeal and hypopharyngeal cancer

  7. Double-Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging.

    Science.gov (United States)

    Mozaffarzadeh, Moein; Sadeghi, Masume; Mahloojifar, Ali; Orooji, Mahdi

    2018-03-01

    In ultrasound (US) imaging, delay and sum (DAS) is the most common beamformer, but it leads to low-quality images. Delay multiply and sum (DMAS) was introduced to address this problem. However, the reconstructed images using DMAS still suffer from the level of side lobes and low noise suppression. Here, a novel beamforming algorithm is introduced based on expansion of the DMAS formula. We found that there is a DAS algebra inside the expansion, and we proposed use of the DMAS instead of the DAS algebra. The introduced method, namely double-stage DMAS (DS-DMAS), is evaluated numerically and experimentally. The quantitative results indicate that DS-DMAS results in an approximately 25% lower level of side lobes compared with DMAS. Moreover, the introduced method leads to 23%, 22% and 43% improvement in signal-to-noise ratio, full width at half-maximum and contrast ratio, respectively, compared with the DMAS beamformer. Copyright © 2018. Published by Elsevier Inc.

  8. Preoperative staging of rectal cancer; Praeoperatives Staging des Rektumkarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, A.O.; Baumann, T.; Pache, G.; Langer, M. [Abt. Roentgendiagnostik, Radiologische Universitaetsklinik Freiburg, Freiburg im Breisgau (Germany); Wiech, T. [Inst. fuer Pathologie, Universitaetsklinik Freiburg, Freiburg (Germany)

    2007-07-15

    Accurate preoperative staging of rectal cancer is crucial for therapeutic decision making, as local tumor extent, nodal status, and patterns of metastatic spread are directly associated with different treatment strategies. Recently, treatment approaches have been widely standardized according to large studies and consensus guidelines. Introduced by Heald, total mesorectal excision (TME) is widely accepted as the surgical procedure of choice to remove the rectum together with its enveloping tissues and the mesorectal fascia. Neoadjuvant radiochemotherapy also plays a key role in the treatment of locally advanced stages, while the use of new drugs will lead to a further improvement in oncological outcome. Visualization of the circumferential resection margin is the hallmark of any preoperative imaging and a prerequisite for high-quality TME surgery. The aim of this article is to present an overview on current cross-sectional imaging with emphasis on magnetic resonance imaging. Future perspectives in rectal cancer imaging are addressed. (orig.)

  9. Staging Hemodynamic Failure With Blood Oxygen-Level-Dependent Functional Magnetic Resonance Imaging Cerebrovascular Reactivity: A Comparison Versus Gold Standard (15O-)H2O-Positron Emission Tomography.

    Science.gov (United States)

    Fierstra, Jorn; van Niftrik, Christiaan; Warnock, Geoffrey; Wegener, Susanne; Piccirelli, Marco; Pangalu, Athina; Esposito, Giuseppe; Valavanis, Antonios; Buck, Alfred; Luft, Andreas; Bozinov, Oliver; Regli, Luca

    2018-03-01

    Increased stroke risk correlates with hemodynamic failure, which can be assessed with ( 15 O-)H 2 O positron emission tomography (PET) cerebral blood flow (CBF) measurements. This gold standard technique, however, is not established for routine clinical imaging. Standardized blood oxygen-level-dependent (BOLD) functional magnetic resonance imaging+CO 2 is a noninvasive and potentially widely applicable tool to assess whole-brain quantitative cerebrovascular reactivity (CVR). We examined the agreement between the 2 imaging modalities and hypothesized that quantitative CVR can be a surrogate imaging marker to assess hemodynamic failure. Nineteen data sets of subjects with chronic cerebrovascular steno-occlusive disease (age, 60±11 years; 4 women) and unilaterally impaired perfusion reserve on Diamox-challenged ( 15 O-)H 2 O PET were studied and compared with a standardized BOLD functional magnetic resonance imaging+CO 2 examination within 6 weeks (8±19 days). Agreement between quantitative CBF- and CVR-based perfusion reserve was assessed. Hemodynamic failure was staged according to PET findings: stage 0: normal CBF, normal perfusion reserve; stage I: normal CBF, decreased perfusion reserve; and stage II: decreased CBF, decreased perfusion reserve. The BOLD CVR data set of the same subjects was then matched to the corresponding stage of hemodynamic failure. PET-based stage I versus stage II could also be clearly separated with BOLD CVR measurements (CVR for stage I 0.11 versus CVR for stage II -0.03; P the affected hemisphere and middle cerebral artery territory ( P the affected hemisphere and middle cerebral artery territory and for identifying hemodynamic failure stage II. BOLD CVR may, therefore, be considered for prospective studies assessing stroke risk in patients with chronic cerebrovascular steno-occlusive disease, in particular because it can potentially be implemented in routine clinical imaging. © 2018 American Heart Association, Inc.

  10. Objective analysis of image quality of video image capture systems

    Science.gov (United States)

    Rowberg, Alan H.

    1990-07-01

    As Picture Archiving and Communication System (PACS) technology has matured, video image capture has become a common way of capturing digital images from many modalities. While digital interfaces, such as those which use the ACR/NEMA standard, will become more common in the future, and are preferred because of the accuracy of image transfer, video image capture will be the dominant method in the short term, and may continue to be used for some time because of the low cost and high speed often associated with such devices. Currently, virtually all installed systems use methods of digitizing the video signal that is produced for display on the scanner viewing console itself. A series of digital test images have been developed for display on either a GE CT9800 or a GE Signa MRI scanner. These images have been captured with each of five commercially available image capture systems, and the resultant images digitally transferred on floppy disk to a PC1286 computer containing Optimast' image analysis software. Here the images can be displayed in a comparative manner for visual evaluation, in addition to being analyzed statistically. Each of the images have been designed to support certain tests, including noise, accuracy, linearity, gray scale range, stability, slew rate, and pixel alignment. These image capture systems vary widely in these characteristics, in addition to the presence or absence of other artifacts, such as shading and moire pattern. Other accessories such as video distribution amplifiers and noise filters can also add or modify artifacts seen in the captured images, often giving unusual results. Each image is described, together with the tests which were performed using them. One image contains alternating black and white lines, each one pixel wide, after equilibration strips ten pixels wide. While some systems have a slew rate fast enough to track this correctly, others blur it to an average shade of gray, and do not resolve the lines, or give

  11. Creating a Magnetic Imaging System for Diagnosing Infant Brain Activity Based on NI PXI and LabVIEW

    Directory of Open Access Journals (Sweden)

    Christopher G. Atwood

    2006-11-01

    Full Text Available Developing a noninvasive magnetic imaging system to spatially and temporally map the magnetic fields generated by brain activity in infants at severe risk of developing cerebral palsy and epilepsy, so that medical doctors can intervene at an early stage.

  12. Self-tuning in master-slave synchronization of high-precision stage systems

    NARCIS (Netherlands)

    Heertjes, M.F.; Temizer, B.; Schneiders, M.G.E.

    2013-01-01

    For synchronization of high-precision stage systems, in particular the synchronization between a wafer and a reticle stage system of a wafer scanner, a master–slave controller design is presented. The design consists of a synchronization controller based on FIR filters and a data-driven self-tuning

  13. Parachute systems for the atmospheric reentry of launcher upper stages

    Directory of Open Access Journals (Sweden)

    Bogdan DOBRESCU

    2017-03-01

    Full Text Available Parachute systems can be used to control the reentry trajectory of launcher upper stages, in order to lower the risks to the population or facilitate the retrieval of the stage. Several types of parachutes deployed at subsonic, supersonic and hypersonic speeds are analyzed, modeled as single and multistage systems. The performance of deceleration parachutes depends on their drag area and deployment conditions, while gliding parachutes are configured to achieve stable flight with a high glide ratio. Gliding parachutes can be autonomously guided to a low risk landing area. Sizing the canopy is shown to be an effective method to reduce parachute sensitivity to wind. The reentry trajectory of a launcher upper stage is simulated for each parachute system configuration and the results are compared to the nominal reentry case.

  14. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    Science.gov (United States)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  15. Analysis of factors responsible for the image in early stage emphysema and research concerning the diagnosis

    International Nuclear Information System (INIS)

    Nakanishi, Hirotaka

    1998-01-01

    To clarify the utility of the CT image to a clinical diagnosis of the early stage emphysema, the relation of CT value to the level of the lung destruction, the change in the lung density and pulmonary function was examined. Experimental pulmonary emphysema model in canine was produced by inhalation of aerosolized papain solution. In this model, the relationship between the destruction in lung tissues and the analysis of CT images was investigated. Changes in the alveolar surface area per unit lung volume well reflected those in mean CT value in the lung parenchyma. Also, it was clarified that the degree of the lung destruction in this model corresponded to that in patients with the early stage emphysema. Mean CT value in the area that formed lowest 5th percentile of the CT value histogram (mCT (5%ile)) was developed to analyze CT images in emphysema. To develop this study, changes of the mCT (5%ile) at the respiratory level from 5% to 95% inspiratory vital capacity (mCT (5%ile (5-95%VC))) was examined. In experimental studies, there was statistical significance between control and emphysema model. In clinical study using 14 patients with emphysema, the mCT (5%ile (5-95%VC)) reflected well the values of pulmonary function tests which indicated air flow limitation such as %pred. FEV 1.0 and MMF. The present studies demonstrated that it might be useful to detect the pathological and functional impairment in the early stage emphysema by using mCT (5%ile (5-95%VC)). (author)

  16. Treatment outcome, body image, and sexual functioning after orchiectomy and radiotherapy for Stage I-II testicular seminoma

    International Nuclear Information System (INIS)

    Incrocci, Luca; Hop, Wim C.J.; Wijnmaalen, Arendjan; Slob, A. Koos

    2002-01-01

    Purpose: Orchiectomy followed by infradiaphragmatic irradiation is the standard treatment for Stage I-II testicular seminoma in The Netherlands. Because body image and sexual functioning can be affected by treatment, a retrospective study was carried out to assess treatment outcome, body image, and changes in sexuality after orchiectomy and radiotherapy. Methods and Materials: The medical charts of 166 patients with Stage I-II testicular seminoma were reviewed. A questionnaire on body image and current sexual functioning regarding the frequency and quality of erections, sexual activity, significance of sex, and changes in sexuality was sent to 157 patients (at a mean of 51 months after treatment). Results: Seventy-eight percent (n=123, mean age 42 years) completed the questionnaire. During irradiation, almost half of patients experienced nausea and 19% nausea and vomiting. Only 3 patients had disease relapse. After treatment, about 20% reported less interest and pleasure in sex and less sexual activity. Interest in sex, erectile difficulties, and satisfaction with sexual life did not differ from age-matched healthy controls. At the time of the survey, 17% of patients had erectile difficulties, a figure that was significantly higher than before treatment, but which correlated also with age. Twenty percent expressed concerns about fertility, and 52% found their body had changed after treatment. Cancer treatment had negatively influenced sexual life in 32% of the patients. Conclusions: Orchiectomy with radiotherapy is an effective and well-tolerated treatment for Stage I-II testicular seminoma. Treatment-induced changes in body image and concerns about fertility were detected, but the sexual problems encountered did not seem to differ from those of healthy controls, although baseline data are lacking

  17. Mechanical design of ultraprecision weak-link stages for nanometer-scale x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shu, D [APS Engineering Support Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Maser, J, E-mail: shu@aps.anl.go [Center for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2009-09-01

    A nanopositioning diagnostic setup has been built to support the Argonne Center for Nanoscale Materials (CNM) nanoprobe instrument commissioning process at the APS. Its laser Doppler interferometer system provides subnanometer positioning diagnostic resolution with large dynamic range. A set of original APS designed ultraprecision PZT-driven weak-link stages with high-stiffness motor-driven stages has been tested with this diagnostic setup. In this paper we present a preliminary test result of the ultraprecision weak-link stage system developed for the CNM hard x-ray nanoprobe instrument at APS sector 26. A test result for a novel laminar weak-link mechanism with sub-centimeter travel range and sub-nanometer positioning resolution is also introduced in this paper as a future work.

  18. Clinical utility of simultaneous whole-body 18F-FDG PET/MRI as a single-step imaging modality in the staging of primary nasopharyngeal carcinoma.

    Science.gov (United States)

    Chan, Sheng-Chieh; Yeh, Chih-Hua; Yen, Tzu-Chen; Ng, Shu-Hang; Chang, Joseph Tung-Chieh; Lin, Chien-Yu; Yen-Ming, Tsang; Fan, Kang-Hsing; Huang, Bing-Shen; Hsu, Cheng-Lung; Chang, Kai-Ping; Wang, Hung-Ming; Liao, Chun-Ta

    2018-03-03

    Both head and neck magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) play a crucial role in the staging of primary nasopharyngeal carcinoma (NPC). In this study, we sought to prospectively investigate the clinical utility of simultaneous whole-body 18F-FDG PET/MRI for primary staging of NPC patients. We examined 113 patients with histologically confirmed NPC who underwent pretreatment, simultaneous whole-body PET/MRI and PET/CT for primary tumor staging. The images obtained with the different imaging modalities were interpreted independently and compared with each other. PET/MRI increased the accuracy of head and neck MRI for assessment of primary tumor extent in four patients via addition of FDG uptake information to increase the conspicuity of morphologically subtle lesions. PET/MR images were more discernible than PET/CT images for mapping tumor extension, especially intracranial invasion. Regarding the N staging assessment, the sensitivity of PET/MRI (99.5%) was higher than that of head and neck MRI (94.2%) and PET/CT (90.9%). PET/MRI was particularly useful for distinguishing retropharyngeal nodal metastasis from adjacent nasopharyngeal tumors. For distant metastasis evaluation, PET/MRI exhibited a similar sensitivity (90% vs. 86.7% vs. 83.3%), but higher positive predictive value (93.1% vs. 78.8% vs. 83.3%) than whole-body MRI and PET/CT, respectively. For tumor staging of NPC, simultaneous whole-body PET/MRI was more accurate than head and neck MRI and PET/CT, and may serve as a single-step staging modality.

  19. The NxStage System One.

    Science.gov (United States)

    Clark, William R; Turk, Joseph E

    2004-01-01

    Given the results of recent randomized controlled trials as well as staffing and budget challenges that today face many institutions across North America, a novel therapeutic approach is likely necessary to enable improvements in clinical outcomes for renal failure patients. The NxStage System One was developed to address these challenges. The system is an innovative, flexible device that delivers hemodialysis, hemofiltration, and/or ultrafiltration therapies to patients with renal failure or fluid overload. The unique characteristics of this system include a highly automated system design with a drop-in cartridge to facilitate training and simple operation; portable size and independence from dedicated infrastructure to minimize practical barriers to where therapy may be administered; use of high-quality premixed treatment fluids to enable capture of the potential clinical benefits of fluid purity without the hassles of local water treatment; and wide operating ranges to allow clinician flexibility in patient therapy prescriptions. In both the chronic and acute care environments, the System One presents clinicians with a new platform for delivering patient therapy improvements within real-world constraints.

  20. Evaluation of the utility of 99m Tc-MDP bone scintigraphy versus MIBG scintigraphy and cross-sectional imaging for staging patients with neuroblastoma.

    Science.gov (United States)

    Gauguet, Jean-Marc; Pace-Emerson, Tamara; Grant, Frederick D; Shusterman, Suzanne; DuBois, Steven G; Frazier, A Lindsay; Voss, Stephan D

    2017-11-01

    Accurate staging of neuroblastoma requires multiple imaging examinations. The purpose of this study was to determine the relative contribution of 99m Tc-methylene diphosphonate (MDP) bone scintigraphy (bone scan) versus metaiodobenzylguanidine scintigraphy (MIBG scan) for accurate staging of neuroblastoma. A medical record search by the identified patients with neuroblastoma from 1993 to 2012 who underwent both MIBG and bone scan for disease staging. Cross-sectional imaging was used to corroborate the scintigraphy results. Clinical records were used to correlate imaging findings with clinical staging and patient management. One hundred thirty-two patients underwent both MIBG and bone scan for diagnosis. All stage 1 (n = 12), 2 (n = 8), and 4S (n = 4) patients had a normal bone scan with no skeletal MIBG uptake. Six of 30 stage 3 patients had false (+) bone scans. In the 78 stage 4 patients, 58/78 (74%) were both skeletal MIBG(+)/bone scan (+). In 56 of the 58 cases, skeletal involvement detected with MIBG was equal to or greater than that detected by bone scan. Only 3/78 had (-) skeletal MIBG uptake and (+) bone scans; all 3 had other sites of metastatic disease. Five of 78 had (+) skeletal MIBG with a (-) bone scan, while 12/78 had no skeletal involvement by either MIBG or bone scan. In no case did a positive bone scan alone determine a stage 4 designation. In the staging of neuroblastoma, 99m Tc-MDP bone scintigraphy does not identify unique sites of disease that affect disease stage or clinical management, and in the majority of cases bone scans can be omitted from the routine neuroblastoma staging algorithm. © 2017 Wiley Periodicals, Inc.

  1. The central nervous system of the fetus in pregnant women after organ-preserving treatment of precancer and early stages of cervical cancer

    International Nuclear Information System (INIS)

    Egorov, O.O.

    2015-01-01

    Magnetic resonance imaging is a promising method of research in tocology. The use of MRI for the first time with high precision anatomical interpretation to diagnose the state of the Central nervous system of the fetus in pregnant women after organ-preserving treatment of precancerous cervical disease and early stages of cervical cancer

  2. Wind Solar Hybrid System Rectifier Stage Topology Simulation

    OpenAIRE

    Anup M. Gakare; Subhash Kamdi

    2014-01-01

    This paper presents power-control strategies of a grid-connected hybrid generation system with versatile power transfer. The hybrid system allows maximum utilization of freely available renewable sources like wind and photovoltaic energies. This paper presents a new system configuration of the multi input rectifier stage for a hybrid wind and photovoltaic energy system. This configuration allows the two sources to supply the load simultaneously depending on the availability of...

  3. Evaluation of the 8th AJCC staging system for pathologically versus clinically staged pancreatic adenocarcinoma: A time to revisit a dogma?

    Science.gov (United States)

    Abdel-Rahman, Omar

    2018-02-01

    The 8th edition of the American Joint Committee on Cancer (AJCC) staging system for pancreatic exocrine adenocarcinoma has been released. The current study seeks to assess the 7th and 8th editions among patients registered within the surveillance, epidemiology and end results (SEER) database. SEER database (2010-2013) has been accessed through SEER*Stat program and AJCC 8th edition stages were reconstructed utilizing the collaborative stage descriptions. Kaplan-Meier analysis of overall survival and pancreatic cancer-specific survival analyses (according to both 7th and 8th editions and according to whether pathological or clinical staging were conducted) has been performed. Multivariate analysis of factors affecting pancreatic cancer-specific survival was also conducted through a Cox proportional hazard model. A total of 18  948 patients with pancreatic adenocarcinoma were identified in the period from 2010-2013. Pancreatic cancer-specific survival among pathologically staged patients and according to the 8th edition showed significant differences for all pair wise comparisons among different stages (P < 0.0001) except for the comparison between stage IA and stage IB (P = 0.307) and the comparison between stage IB and stage IIA (P = 0.116). Moreover, P value for stage IA vs IIA was 0.014; while pancreatic cancer-specific survival according to the 7th edition among pathologically staged patients showed significant differences for all pair wise comparisons among different stages (P < 0.0001) except for the comparison between IA and IB (P = 0.072), the comparison between stage IIA and stage IIB (P = 0.065), the comparison between stage IIA and stage III (P = 0.059) and the comparison between IIB and III (P = 0.595). Among clinically staged patients (i.e. those who did not undergo initial radical surgery), the prognostic performance of both 7th and 8th stages for both overall survival and pancreatic cancer-specific survival was

  4. Multispectral system for medical fluorescence imaging

    International Nuclear Information System (INIS)

    Andersson, P.S.; Montan, S.; Svanberg, S.

    1987-01-01

    The principles of a powerful multicolor imaging system for tissue fluorescence diagnostics are discussed. Four individually spectrally filtered images are formed on a matrix detector by means of a split-mirror arrangement. The four images are processed in a computer, pixel by pixel, by means of mathematical operations, leading to an optimized contrast image, which enhances a selected feature. The system is being developed primarily for medical fluorescence imaging, but has wide applications in fluorescence, reflectance, and transmission monitoring related to a wide range of industrial and environmental problems. The system operation is described for the case of linear imaging on a diode array detector. Laser-induced fluorescence is used for cancer tumor and arteriosclerotic plaque demarcation using the contrast enhancement capabilities of this imaging system. Further examples of applications include fluorescing minerals and flames

  5. A Thermoelectric Generation System and Its Power Electronics Stage

    DEFF Research Database (Denmark)

    Gao, Junling; Sun, Kai; Ni, Longxian

    2012-01-01

    stage and signal-conditioning circuits of the load, including DC–DC conversion, the maximum power point tracking (MPPT) controller, and other power management controllers. In this paper, a survey of existing power electronics designs for TEG systems is presented first. Second, a flat, wall-like TEG...... system consisting of 32 modules is experimentally optimized, and the improved power parameters are tested. Power-conditioning circuitry based on an interleaved boost DC–DC converter is then developed for the TEG system in terms of the tested power specification. The power electronics design features...... a combined control scheme with an MPPT and a constant output voltage as well as the low-voltage and high-current output characteristics of the TEG system. The experimental results of the TEG system with the power electronics stage and with purely resistive loads are compared. The comparisons verify...

  6. New procedures. Comprehensive staging of lung cancer by MRI; Neue Verfahren. Umfassendes Staging des Lungenkarzinoms mit der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Hintze, C. [Universitaetsklinikum Schleswig-Holstein, Campus Kiel, Klinik fuer Diagnostische Radiologie, Kiel (Germany); Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Dinkel, J. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Biederer, J. [Universitaetsklinikum Schleswig-Holstein, Campus Kiel, Klinik fuer Diagnostische Radiologie, Kiel (Germany); Heussel, C.P. [Thoraxklinik Heidelberg, Abteilung Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Puderbach, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Thoraxklinik Heidelberg, Abteilung Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2010-08-15

    Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [German] Das Staging des Lungenkarzinoms nach dem TNM-System basiert auf der morphologischen Einschaetzung des Primarius, der Lymphknoten und Metastasen. Alle Aspekte dieser onkologisch wichtigen Beurteilung lassen sich mit der MRT erfassen. Pulmonale Rundherde sind ab der klinisch relevanten Groesse von 4-5 mm Durchmesser sicher erkennbar. Die Groesse der mediastinalen, hilaeren und supraklavikulaeren Lymphknoten kann in einem Untersuchungsgang bestimmt werden. In der koronaren Schichtfuehrung der dedizierten MRT der Lunge werden die Bereiche der bevorzugten Metastasierung in Nebennieren und weite Teile der Wirbelsaeule miterfasst. Durch eine gezielte Ganzkoerper-MRT als Suchmethode wird der letzte Teil des Stagings erfuellt. Die MRT bietet vielfaeltige Moeglichkeiten, zusaetzliche funktionelle, klinisch relevante Informationen innerhalb einer Untersuchung zu erheben. Im onkologischen Kontext sind die Perfusionsbildgebung der Lunge und die Bewegungsabschaetzung der Tumoren am bedeutendsten. Die funktionelle MRT der

  7. Liver-inherent immune system: its role in blood-stage malaria.

    Science.gov (United States)

    Wunderlich, Frank; Al-Quraishy, Saleh; Dkhil, Mohamed A

    2014-01-01

    The liver is well known as that organ which is obligately required for the intrahepatocyte development of the pre-erythrocytic stages of the malaria-causative agent Plasmodium. However, largely neglected is the fact that the liver is also a central player of the host defense against the morbidity- and mortality-causing blood stages of the malaria parasites. Indeed, the liver is equipped with a unique immune system that acts locally, however, with systemic impact. Its main "antipodal" functions are to recognize and to generate effective immunoreactivity against pathogens on the one hand, and to generate tolerance to avoid immunoreactivity with "self" and harmless substances as dietary compounds on the other hand. This review provides an introductory survey of the liver-inherent immune system: its pathogen recognition receptors including Toll-like receptors (TLRs) and its major cell constituents with their different facilities to fight and eliminate pathogens. Then, evidence is presented that the liver is also an essential organ to overcome blood-stage malaria. Finally, we discuss effector responses of the liver-inherent immune system directed against blood-stage malaria: activation of TLRs, acute phase response, phagocytic activity, cytokine-mediated pro- and anti-inflammatory responses, generation of "protective" autoimmunity by extrathymic T cells and B-1 cells, and T cell-mediated repair of liver injuries mainly produced by malaria-induced overreactions of the liver-inherent immune system.

  8. Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y.R. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of); The Catholic University of Korea, Department of Radiology, Incheon St. Mary' s Hospital, College of Medicine, Bupyeong 6-dong, Bupyeong-gu, Incheon (Korea, Republic of); Rha, S.E.; Choi, B.G.; Oh, S.N.; Park, M.Y.; Byun, J.Y. [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, 222, Banpo-daero, Seocho-gu, Seoul (Korea, Republic of)

    2013-04-15

    To compare three-dimensional (3D) T2-weighted turbo spin-echo (TSE) with multiplanar two-dimensional (2D) T2-weighted TSE for the evaluation of invasive cervical carcinoma. Seventy-five patients with cervical carcinoma underwent MRI of the pelvis at 3.0 T, using both 5-mm-thick multiplanar 2D (total acquisition time = 12 min 25 s) and 1-mm-thick coronal 3D T2-weighted TSE sequences (7 min 20 s). Quantitative analysis of signal-to-noise ratio (SNR) and qualitative analysis of image quality were performed. Local-regional staging was performed in 45 patients who underwent radical hysterectomy. The estimated SNR of cervical carcinoma and the relative tumour contrast were significantly higher on 3D imaging (P < 0.0001). Tumour conspicuity was better with the 3D sequence, but the sharpness of tumour margin was better with the 2D sequence. No significant difference in overall image quality was noted between the two sequences (P = 0.38). There were no significant differences in terms of the diagnostic accuracy, sensitivity, and specificity of parametrial invasion, vaginal invasion, and lymph node metastases. Multiplanar reconstruction 3D T2-weighted imaging is largely equivalent to 2D T2-weighted imaging for overall image quality and staging accuracy of cervical carcinoma with a shorter MR data acquisition, but has limitations with regard to the sharpness of the tumour margin. circle 3D T2-weighted MR sequence is equivalent to 2D for cervical carcinoma staging. (orig.)

  9. Effectiveness of interim stage filter in the exhaust system of glove boxes

    International Nuclear Information System (INIS)

    Patre, D.K.; Vangara, H.; Thanamani, S.; Gopalakrishnan, R.K.; Mhatre, Amol M.

    2018-01-01

    All operations in radiochemical laboratories are carried out in containment systems like Glove boxes and Fume hoods. For controlling air contamination two separate air cleaning systems are incorporated. Laboratory has general ventilation system and glove boxes are provided with a negative pressure system (NPS). Glove box exhaust air is passed through three stage filtration systems: in situ, interim and final before discharging to the atmosphere. In addition to the individual HEPA filters of each glove box, there is an interim HEPA filter bank introduced at the laboratory end. This was introduced to reduce a load on main exhaust filter system. Finally the exhaust air is discharged through the final stage HEPA filter located in the filter house through the Stack. The interim HEPA filter bank provides additional protection for the release of particulate activity and reduces load on the final stage filters. In the present work efforts have been put to validate the interim stage filter, which has been introduced, to limit the environmental release

  10. Preliminary results of endorectal surface coil magnetic resonance imaging for local staging of prostate cancer

    International Nuclear Information System (INIS)

    Jager, G.H.; Barentsz, J.O.; Rosette, J.J.M.C.H. de la; Rosenbusch, G.

    1994-01-01

    Objective: To evaluate the effectiveness of endorectal surface coil (ERC) magnetic resonance imaging (MRI) in the local staging of adenocarcinoma of the prostate (ACP). Materials and methods: A total of 23 patients who were considered candidates for radical prostatectomy because of clinically localized ACP were examined by ERC-MRI. All patients underwent laparoscopic or open lymph-node dissection prior to surgery. Four patients had positive lymph nodes at operation. A total of 19 underwant radical prostatectomy, allowing comparison of the MRI data with the surgical pathologic findings. Results: Twelve patients had extraglandular spread of ACP (T3) and 7 had locally confined ACP (T2). ERC-MRI predicted correctly a T3 tumor in 10 of 12 cases and a T2 tumor in 4 of 7 cases. ERC-MRI was 74% accurate in differentiating T2 from T3 tumor. Three cases of overestimation were in studies with poor image quality because of bowel movement motion artifacts. Conclusion: ERC-MRI was found to be a sensitive modality in staging clinically localized ACP. (orig.) [de

  11. New managing system of a large amount of images on Tore Supra

    International Nuclear Information System (INIS)

    Buravand, Y.; Ducobu, L.; Guilhem, D.; Roche, H.; Signoret, J.; Travere, J.M.; Utzel, N.

    2004-01-01

    After a major replacement of all internal components (terminated in 2002), Tore Supra has restarted operation with a new set of actively cooled components. The safety of these components relies on infrared (IR) thermography. Up to twelve IR cameras will be used to survey nearly all the high flux target zones which are essentially the 360 deg C toroidal pump limiter and the 5 power injection HF antennas. The high data rate produced by each camera ( ∼ 8 Mbytes/sec.) led us to implement a multi stages system: during experimentations, images are stored where they are acquired then, each night they are compressed using a lossy standard image compression algorithm (JPEG) and stored on a specialized IR data server. Between shots, acquisition systems act as servers and physicists can read data using a dedicated analysis software. For post-analysis purposes, all compressed images are read from the IR data server using the same analysis software or for in-depth analysis, physicists can use the Matlab interface we have developed. (authors)

  12. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  13. Dynamic MR imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Shah, A.S.; Hylton, H.; Hentz, V.R.; Schattner, P.

    1991-01-01

    This paper reports on dynamic MR imaging which is an MR technique that allows imaging of the musculoskeletal system in motion. Current methods for observing the articulation of muscles and joints are limited to acquisition of stationary images at different spatial orientations. These images are then replayed from computer memory to simulate motion. Unlike stationary acquisition, dynamic MR imaging allows the volume of interest to be subjected to motion and dynamic stress, which is important for detecting stress-induced pathology. To demonstrate the utility of dynamic MR imaging, a system for imaging a moving wrist has been developed. The system consists of apparatus capable of providing simultaneous radialulnar deviation and flexion-extension, and hardware for system control and acquisition gating. The apparatus is mounted on the patient bed and is transferable to a variety of standard clinical MR imaging systems. Images were obtained during motion, and the ability of dynamic MR imaging to accurately image the moving wrist with very little motion artifact was demonstrated

  14. Bone marrow abnormality associated with painful osteoarthritis of the knee. A cross-sectional study of magnetic resonance imaging findings with the radiographic stage and clinical findings

    International Nuclear Information System (INIS)

    Kubota, Mitsuaki; Kurosawa, Hisashi; Ikeda, Hiroshi; Takazawa, Yuji; Kawasaki, Takayuki; Ishijima, Muneaki; Kim, Song-Gon; Seto, Hiroaki

    2009-01-01

    Bone marrow abnormalities (BMAs) are frequently found in osteoarthritis (OA) of the knee with magnetic resonance imaging (MRI). Some reports have suggested BMA was correlated with the X-ray stage of OA and also with knee pain, but the reports depended on two-dimensional images without considering the spatial expansion of BMAs. To determine whether three-dimensional expansion of a BMA with MRI in patient with medial-type OA of the knee is correlated with the radiographic stage of OA and clinical findings using a semi-quantitative method. Cross-sectional study. This study enrolled 238 patients with medial-type OA. Radiography and MRI of the knee were taken in all participants. X-rays were graded using the Kellgren-Lawrence (K/L) grade (1-4). T2-weighted fat-suppressed MRI images were used to score the size of the BMA according to the whole-organ MRI score (WORMS). A new scoring system defined as the spatial BMA score (s-score), which specifically addressed the spatial expansion of BMAs, was examined to assess the size of the BMA. BMA frequency was examined in subdivisions of the articular surfaces of the knee according to the X-ray stages of the K/L grade and the correlation of the s-score to the clinical findings. BMA frequency in the medial femorotibial joint (MFTJ; 74%) was significantly higher than in the lateral femorotibial joint (LFTJ; 14%) and patellofemoral joint (PFJ; 14%; P<0.01). The s-score of the MFTJ was strongly correlated with the X-ray stage assessed by the K/L grade. The s-score of the MFTJ was also correlated with the clinical findings. The frequency and spatial expansion of BMAs in the MFTJ are strongly correlated with the X-ray stage of medial-type OA as well as the clinical findings. (author)

  15. End-stage kidney disease

    Science.gov (United States)

    ... stage; Kidney failure - end stage; ESRD; ESKD Images Kidney anatomy References Fogarty DG, Taal MW. A stepped care approach to the management of chronic kidney disease. In: Skorecki K, Chertow GM, Marsden PA, ...

  16. Alternatives generation and analysis for phase I intermediate waste feed staging system design requirements

    Energy Technology Data Exchange (ETDEWEB)

    Britton, M.D.

    1996-10-02

    This document provides; a decision analysis summary; problem statement; constraints, requirements, and assumptions; decision criteria; intermediate waste feed staging system options and alternatives generation and screening; intermediate waste feed staging system design concepts; intermediate waste feed staging system alternative evaluation and analysis; and open issues and actions.

  17. FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

    International Nuclear Information System (INIS)

    Bassi, Maria Chiara; Turri, Lucia; Sacchetti, Gianmauro; Loi, Gianfranco; Cannillo, Barbara; La Mattina, Pierdaniele; Brambilla, Marco; Inglese, Eugenio; Krengli, Marco

    2008-01-01

    Purpose: To investigate the potential impact of using 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively

  18. A Gas-Spring-Loaded X-Y-Z Stage System for X-ray Microdiffraction Sample Manipulation

    International Nuclear Information System (INIS)

    Shu Deming; Cai Zhonghou; Lai, Barry

    2007-01-01

    We have designed and constructed a gas-spring-loaded x-y-z stage system for x-ray microdiffraction sample manipulation at the Advanced Photon Source XOR 2-ID-D station. The stage system includes three DC-motor-driven linear stages and a gas-spring-based heavy preloading structure, which provides antigravity forces to ensure that the stage system keeps high-positioning performance under variable goniometer orientation. Microdiffraction experiments with this new stage system showed significant sample manipulation performance improvement

  19. A Three-Stage Optimal Approach for Power System Economic Dispatch Considering Microgrids

    Directory of Open Access Journals (Sweden)

    Wei-Tzer Huang

    2016-11-01

    Full Text Available The inclusion of microgrids (MGs in power systems, especially distribution-substation-level MGs, significantly affects power systems because of the large volumes of import and export power flows. Consequently, power dispatch has become complicated, and finding an optimal solution is difficult. In this study, a three-stage optimal power dispatch model is proposed to solve such dispatch problems. In the proposed model, the entire power system is divided into two parts, namely, the main power grid and MGs. The optimal power dispatch problem is resolved on the basis of multi-area concepts. In stage I, the main power system economic dispatch (ED problem is solved by sensitive factors. In stage II, the optimal power dispatches of the local MGs are addressed via an improved direct search method. In stage III, the incremental linear models for the entire power system can be established on the basis of the solutions of the previous two stages and can be subjected to linear programming to determine the optimal reschedules from the original dispatch solutions. The proposed method is coded using Matlab and tested by utilizing an IEEE 14-bus test system to verify its feasibility and accuracy. Results demonstrated that the proposed approach can be used for the ED of power systems with MGs as virtual power plants.

  20. Staging of lung cancer.

    Science.gov (United States)

    de Groot, Patricia M; Carter, Brett W; Betancourt Cuellar, Sonia L; Erasmus, Jeremy J

    2015-06-01

    Primary lung cancer is the leading cause of cancer mortality in the world. Thorough clinical staging of patients with lung cancer is important, because therapeutic options and management are to a considerable degree dependent on stage at presentation. Radiologic imaging is an essential component of clinical staging, including chest radiography in some cases, computed tomography, MRI, and PET. Multiplanar imaging modalities allow assessment of features that are important for surgical, oncologic, and radiation therapy planning, including size of the primary tumor, location and relationship to normal anatomic structures in the thorax, and existence of nodal and/or metastatic disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Management of severe subarachnoid hemorrhage (SAH) with diffusion-weighted imaging in acute stage

    International Nuclear Information System (INIS)

    Shamoto, Hiroshi; Shimizu, Hiroaki; Matsumoto, Yasushi; Fujiwara, Satoru; Tominaga, Teiji

    2007-01-01

    Determining the treatment strategy of severe subarachnoid hemorrhage (SAH) (Hunt and Kosnik Grade 4 and 5) requires objective evaluation to represent severity. In the present study, we investigated the role of diffusion-weighted imaging (DWI) in the acute stage as an objective tool. DWI was performed within 48 hours after the onset and preoperatively in 36 patients who fulfilled following the inclusion criteria: admission Hunt and Kosnik Grade 4 or 5, and Fischer Group 3. Twelve of 14 patients without abnormal findings in DWI underwent surgery in the acute stage. Although 2 of 14 patients with high age were supposed to undergo surgery in the chronic stage, 1 patient died in aneurysmal re-rupture. Glasgow outcome scales (GOS) were good recovery (GR) in 5, moderate disability (MD) in 6, standard deviation (SD) in 1 and D in 2 patients. Thirteen of 22 patients with DWI abnormality had small lesions less than 10 mm in diameter. Twelve of 13 patients underwent surgery in the acute stage, and 1 died of aneurysmal re-rupture while waiting for surgery in the chronic stage. GOS were GR in 3, MD in 4, SD in 3 and D in 3 patients. Although 5 patients with diffuse DWI lesions underwent surgery in the acute stage, 2 were SD and 3 were D. Four patients were supposed to undergo delayed surgery. However, 2 of them died of recurrent hemorrhage while waiting. GOS were SD in 2 and D in 2 patients. The present study indicates that DWI may provide objective evaluation of brain damage in severe SAH. However, since there were varieties of DWI findings and clinical courses, careful decisions must be taken in management of severe SAH patients. (author)

  2. Reassessing the NTCTCS Staging Systems for Differentiated Thyroid Cancer, Including Age at Diagnosis.

    Science.gov (United States)

    McLeod, Donald S A; Jonklaas, Jacqueline; Brierley, James D; Ain, Kenneth B; Cooper, David S; Fein, Henry G; Haugen, Bryan R; Ladenson, Paul W; Magner, James; Ross, Douglas S; Skarulis, Monica C; Steward, David L; Xing, Mingzhao; Litofsky, Danielle R; Maxon, Harry R; Sherman, Steven I

    2015-10-01

    Thyroid cancer is unique for having age as a staging variable. Recently, the commonly used age cut-point of 45 years has been questioned. This study assessed alternate staging systems on the outcome of overall survival, and compared these with current National Thyroid Cancer Treatment Cooperative Study (NTCTCS) staging systems for papillary and follicular thyroid cancer. A total of 4721 patients with differentiated thyroid cancer were assessed. Five potential alternate staging systems were generated at age cut-points in five-year increments from 35 to 70 years, and tested for model discrimination (Harrell's C-statistic) and calibration (R(2)). The best five models for papillary and follicular cancer were further tested with bootstrap resampling and significance testing for discrimination. The best five alternate papillary cancer systems had age cut-points of 45-50 years, with the highest scoring model using 50 years. No significant difference in C-statistic was found between the best alternate and current NTCTCS systems (p = 0.200). The best five alternate follicular cancer systems had age cut-points of 50-55 years, with the highest scoring model using 50 years. All five best alternate staging systems performed better compared with the current system (p = 0.003-0.035). There was no significant difference in discrimination between the best alternate system (cut-point age 50 years) and the best system of cut-point age 45 years (p = 0.197). No alternate papillary cancer systems assessed were significantly better than the current system. New alternate staging systems for follicular cancer appear to be better than the current NTCTCS system, although they require external validation.

  3. Reassessing the NTCTCS Staging Systems for Differentiated Thyroid Cancer, Including Age at Diagnosis

    Science.gov (United States)

    McLeod, Donald S.A.; Jonklaas, Jacqueline; Brierley, James D.; Ain, Kenneth B.; Cooper, David S.; Fein, Henry G.; Haugen, Bryan R.; Ladenson, Paul W.; Magner, James; Ross, Douglas S.; Skarulis, Monica C.; Steward, David L.; Xing, Mingzhao; Litofsky, Danielle R.; Maxon, Harry R.

    2015-01-01

    Background: Thyroid cancer is unique for having age as a staging variable. Recently, the commonly used age cut-point of 45 years has been questioned. Objective: This study assessed alternate staging systems on the outcome of overall survival, and compared these with current National Thyroid Cancer Treatment Cooperative Study (NTCTCS) staging systems for papillary and follicular thyroid cancer. Methods: A total of 4721 patients with differentiated thyroid cancer were assessed. Five potential alternate staging systems were generated at age cut-points in five-year increments from 35 to 70 years, and tested for model discrimination (Harrell's C-statistic) and calibration (R2). The best five models for papillary and follicular cancer were further tested with bootstrap resampling and significance testing for discrimination. Results: The best five alternate papillary cancer systems had age cut-points of 45–50 years, with the highest scoring model using 50 years. No significant difference in C-statistic was found between the best alternate and current NTCTCS systems (p = 0.200). The best five alternate follicular cancer systems had age cut-points of 50–55 years, with the highest scoring model using 50 years. All five best alternate staging systems performed better compared with the current system (p = 0.003–0.035). There was no significant difference in discrimination between the best alternate system (cut-point age 50 years) and the best system of cut-point age 45 years (p = 0.197). Conclusions: No alternate papillary cancer systems assessed were significantly better than the current system. New alternate staging systems for follicular cancer appear to be better than the current NTCTCS system, although they require external validation. PMID:26203804

  4. A Multi-stage Method to Extract Road from High Resolution Satellite Image

    International Nuclear Information System (INIS)

    Zhijian, Huang; Zhang, Jinfang; Xu, Fanjiang

    2014-01-01

    Extracting road information from high-resolution satellite images is complex and hardly achieves by exploiting only one or two modules. This paper presents a multi-stage method, consisting of automatic information extraction and semi-automatic post-processing. The Multi-scale Enhancement algorithm enlarges the contrast of human-made structures with the background. The Statistical Region Merging segments images into regions, whose skeletons are extracted and pruned according to geometry shape information. Setting the start and the end skeleton points, the shortest skeleton path is constructed as a road centre line. The Bidirectional Adaptive Smoothing technique smoothens the road centre line and adjusts it to right position. With the smoothed line and its average width, a Buffer algorithm reconstructs the road region easily. Seen from the last results, the proposed method eliminates redundant non-road regions, repairs incomplete occlusions, jumps over complete occlusions, and reserves accurate road centre lines and neat road regions. During the whole process, only a few interactions are needed

  5. Mechanics of bioinspired imaging systems

    Directory of Open Access Journals (Sweden)

    Zhengwei Li

    2016-01-01

    Full Text Available Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics. Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates.

  6. Forensic age estimation based on development of third molars: a staging technique for magnetic resonance imaging.

    Science.gov (United States)

    De Tobel, J; Phlypo, I; Fieuws, S; Politis, C; Verstraete, K L; Thevissen, P W

    2017-12-01

    The development of third molars can be evaluated with medical imaging to estimate age in subadults. The appearance of third molars on magnetic resonance imaging (MRI) differs greatly from that on radiographs. Therefore a specific staging technique is necessary to classify third molar development on MRI and to apply it for age estimation. To develop a specific staging technique to register third molar development on MRI and to evaluate its performance for age estimation in subadults. Using 3T MRI in three planes, all third molars were evaluated in 309 healthy Caucasian participants from 14 to 26 years old. According to the appearance of the developing third molars on MRI, descriptive criteria and schematic representations were established to define a specific staging technique. Two observers, with different levels of experience, staged all third molars independently with the developed technique. Intra- and inter-observer agreement were calculated. The data were imported in a Bayesian model for age estimation as described by Fieuws et al. (2016). This approach adequately handles correlation between age indicators and missing age indicators. It was used to calculate a point estimate and a prediction interval of the estimated age. Observed age minus predicted age was calculated, reflecting the error of the estimate. One-hundred and sixty-six third molars were agenetic. Five percent (51/1096) of upper third molars and 7% (70/1044) of lower third molars were not assessable. Kappa for inter-observer agreement ranged from 0.76 to 0.80. For intra-observer agreement kappa ranged from 0.80 to 0.89. However, two stage differences between observers or between staging sessions occurred in up to 2.2% (20/899) of assessments, probably due to a learning effect. Using the Bayesian model for age estimation, a mean absolute error of 2.0 years in females and 1.7 years in males was obtained. Root mean squared error equalled 2.38 years and 2.06 years respectively. The performance to

  7. High sensitivity optical molecular imaging system

    Science.gov (United States)

    An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie

    2018-02-01

    Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.

  8. Image processing of integrated video image obtained with a charged-particle imaging video monitor system

    International Nuclear Information System (INIS)

    Iida, Takao; Nakajima, Takehiro

    1988-01-01

    A new type of charged-particle imaging video monitor system was constructed for video imaging of the distributions of alpha-emitting and low-energy beta-emitting nuclides. The system can display not only the scintillation image due to radiation on the video monitor but also the integrated video image becoming gradually clearer on another video monitor. The distortion of the image is about 5% and the spatial resolution is about 2 line pairs (lp)mm -1 . The integrated image is transferred to a personal computer and image processing is performed qualitatively and quantitatively. (author)

  9. Understanding X-ray cargo imaging

    International Nuclear Information System (INIS)

    Chen Gongyin

    2005-01-01

    Cargo imaging is the field of imaging large objects, usually cargo containers, trains, trucks or boats. Transmission imaging with photons, especially X-rays of up to 9 MV is the dominant current technique, providing compelling details of the contents of objects this large. This paper discusses the physics aspects of a good X-ray cargo imaging system. The basic performance requirements, such as penetration, contrast and resolution and the components of a cargo imaging system are introduced. The imaging process is divided in this paper into three stages: forming information (probing the object), recording information and presenting information (image display). Their impact on performance is analyzed

  10. Stereoscopic medical imaging collaboration system

    Science.gov (United States)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  11. A New Method Based on Two-Stage Detection Mechanism for Detecting Ships in High-Resolution SAR Images

    Directory of Open Access Journals (Sweden)

    Xu Yongli

    2017-01-01

    Full Text Available Ship detection in synthetic aperture radar (SAR remote sensing images, being a fundamental but challenging problem in the field of satellite image analysis, plays an important role for a wide range of applications and is receiving significant attention in recent years. Aiming at the requirements of ship detection in high-resolution SAR images, the accuracy, the intelligent level, a better real-time operation and processing efficiency, The characteristics of ocean background and ship target in high-resolution SAR images were analyzed, we put forward a ship detection algorithm in high-resolution SAR images. The algorithm consists of two detection stages: The first step designs a pre-training classifier based on improved spectral residual visual model to obtain the visual salient regions containing ship targets quickly, then achieve the purpose of probably detection of ships. In the second stage, considering the Bayesian theory of binary hypothesis detection, a local maximum posterior probability (MAP classifier is designed for the classification of pixels. After the parameter estimation and judgment criterion, the classification of pixels are carried out in the target areas to achieve the classification of two types of pixels in the salient regions. In the paper, several types of satellite image data, such as TerraSAR-X (TS-X, Radarsat-2, are used to evaluate the performance of detection methods. Comparing with classical CFAR detection algorithms, experimental results show that the algorithm can achieve a better effect of suppressing false alarms, which caused by the speckle noise and ocean clutter background inhomogeneity. At the same time, the detection speed is increased by 25% to 45%.

  12. Revised FIGO staging system for cancer of the ovary, fallopian tube, and peritoneum: important implications for radiologists.

    Science.gov (United States)

    Saida, Tsukasa; Tanaka, Yumiko Oishi; Matsumoto, Koji; Satoh, Toyomi; Yoshikawa, Hiroyuki; Minami, Manabu

    2016-02-01

    Ovarian cancer is the seventh most common cancer diagnosis among women worldwide. The International Federation of Gynecology and Obstetrics recently significantly revised staging criteria for cancer of the ovary. The latest revision was based on the concept that high-grade serous tubal intraepithelial carcinoma (STIC) may be the origin of some high-grade serous carcinomas of the ovary and peritoneum. Therefore, staging criteria for the ovary, fallopian tube, and peritoneum have been unified. Understanding this background and other important revised points are essential for radiologists concerned with imaging diagnosis in gynecologic oncology. Through this review, we introduce the STIC theory and show examples of diseases in accordance with the new staging criteria based on magnetic resonance imaging (MRI) and computed tomography (CT) results.

  13. New procedures. Comprehensive staging of lung cancer by MRI

    International Nuclear Information System (INIS)

    Hintze, C.; Dinkel, J.; Biederer, J.; Heussel, C.P.; Puderbach, M.

    2010-01-01

    Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [de

  14. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  15. Imaging modalities for staging esophageal carcinoma

    International Nuclear Information System (INIS)

    Mattioli, S.; Pezzi, A.; Brusori, S.; Brusori, G.; Di Simone, M.P.; Gozzetti, G.; Gigli, F.

    1991-01-01

    Forty-four patients affected with thoracic esophageal carcinoma underwent preoperative CT to evaluate the value of this method in both staging and assessing the resectability of esophageal tumors. The authors compared the CTfindings with intraoperative macroscopei ones, pathologic, and bronchoscopic results in mid-high neoplasms. CT staging criteria were drawn from a careful review of literature and from personal experience. thirty-nine patients were submitted to surgery, and esophagectomy was possible in 34 of them. CT diagnostic accuracy was higher in proximal esophageal tumors than in sub-bronchial ones; as for the surgical choice, CT provided fundamental guidelines,especially if the choice was a blunt esophagectomy where it is important to exclude tumoral involvement of the airways (accuracy: 82.6%) or of the aorta (accuracy: 89.7%). CT staging accuracy was limited by the low sensitivity of the method in detecting lymphatic ( local: 66.6%, distant: 64.2%) and hepatic metastates. Combined thoraco-abdominal CT, tracheo-bronchoscopy and liver US, besides MR imgaging and endoscopic US, allow a better preoperative evaluation of esophageal carcinomas

  16. Automated imaging system for single molecules

    Science.gov (United States)

    Schwartz, David Charles; Runnheim, Rodney; Forrest, Daniel

    2012-09-18

    There is provided a high throughput automated single molecule image collection and processing system that requires minimal initial user input. The unique features embodied in the present disclosure allow automated collection and initial processing of optical images of single molecules and their assemblies. Correct focus may be automatically maintained while images are collected. Uneven illumination in fluorescence microscopy is accounted for, and an overall robust imaging operation is provided yielding individual images prepared for further processing in external systems. Embodiments described herein are useful in studies of any macromolecules such as DNA, RNA, peptides and proteins. The automated image collection and processing system and method of same may be implemented and deployed over a computer network, and may be ergonomically optimized to facilitate user interaction.

  17. Digital image information systems in radiology

    International Nuclear Information System (INIS)

    Greinacher, C.F.C.; Luetke, B.; Seufert, G.

    1987-01-01

    About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de

  18. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    Science.gov (United States)

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  19. Scorpion image segmentation system

    Science.gov (United States)

    Joseph, E.; Aibinu, A. M.; Sadiq, B. A.; Bello Salau, H.; Salami, M. J. E.

    2013-12-01

    Death as a result of scorpion sting has been a major public health problem in developing countries. Despite the high rate of death as a result of scorpion sting, little report exists in literature of intelligent device and system for automatic detection of scorpion. This paper proposed a digital image processing approach based on the floresencing characteristics of Scorpion under Ultra-violet (UV) light for automatic detection and identification of scorpion. The acquired UV-based images undergo pre-processing to equalize uneven illumination and colour space channel separation. The extracted channels are then segmented into two non-overlapping classes. It has been observed that simple thresholding of the green channel of the acquired RGB UV-based image is sufficient for segmenting Scorpion from other background components in the acquired image. Two approaches to image segmentation have also been proposed in this work, namely, the simple average segmentation technique and K-means image segmentation. The proposed algorithm has been tested on over 40 UV scorpion images obtained from different part of the world and results obtained show an average accuracy of 97.7% in correctly classifying the pixel into two non-overlapping clusters. The proposed 1system will eliminate the problem associated with some of the existing manual approaches presently in use for scorpion detection.

  20. Configuration of management accounting information system for multi-stage manufacturing

    Science.gov (United States)

    Mkrtychev, S. V.; Ochepovsky, A. V.; Enik, O. A.

    2018-05-01

    The article presents an approach to configuration of a management accounting information system (MAIS) that provides automated calculations and the registration of normative production losses in multi-stage manufacturing. The use of MAIS with the proposed configuration at the enterprises of textile and woodworking industries made it possible to increase the accuracy of calculations for normative production losses and to organize accounting thereof with the reference to individual stages of the technological process. Thus, high efficiency of multi-stage manufacturing control is achieved.

  1. Compression-Based Tools for Navigation with an Image Database

    Directory of Open Access Journals (Sweden)

    Giovanni Motta

    2012-01-01

    Full Text Available We present tools that can be used within a larger system referred to as a passive assistant. The system receives information from a mobile device, as well as information from an image database such as Google Street View, and employs image processing to provide useful information about a local urban environment to a user who is visually impaired. The first stage acquires and computes accurate location information, the second stage performs texture and color analysis of a scene, and the third stage provides specific object recognition and navigation information. These second and third stages rely on compression-based tools (dimensionality reduction, vector quantization, and coding that are enhanced by knowledge of (approximate location of objects.

  2. Underwater laser imaging system (UWLIS)

    Energy Technology Data Exchange (ETDEWEB)

    DeLong, M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Practical limitations with underwater imaging systems area reached when the noise in the back scattered radiation generated in the water between the imaging system and the target obscures the spatial contrast and resolution necessary for target discovery and identification. The advent of high power lasers operating in the blue-green portion of the visible spectrum (oceanic transmission window) has led to improved experimental illumination systems for underwater imaging. Range-gated and synchronously scanned devices take advantage of the unique temporal and spatial coherence properties of laser radiation, respectively, to overcome the deleterious effects of common volume back scatter.

  3. Two-stage model of development of heterogeneous uranium-lead systems in zircon

    International Nuclear Information System (INIS)

    Mel'nikov, N.N.; Zevchenkov, O.A.

    1985-01-01

    Behaviour of isotope systems of multiphase zircons at their two-stage distortion is considered. The results of calculations testify to the fact that linear correlations on the diagram with concordance can be explained including two-stage discovery of U-Pb systems of cogenetic zircons if zircon is considered physically heterogeneous and losing in its different part different ratios of accumulated radiogenic lead. ''Metamorphism ages'' obtained by these two-stage opening zircons are intermediate, and they not have geochronological significance while ''crystallization ages'' remain rather close to real ones. Two-stage opening zircons in some cases can be diagnosed by discordance of their crystal component

  4. Changes of endocrine and ultrasound markers as ovarian aging in modifying the Stages of Reproductive Aging Workshop (STRAW) staging system with subclassification of mid reproductive age stage.

    Science.gov (United States)

    Ding, Ting; Luo, Aiyue; Jiang, Jingjing; Du, Xiaofang; Yang, Shuhong; Lai, Zhiwen; Shen, Wei; Lu, Yunping; Ma, Ding; Wang, Shixuan

    2013-01-01

    To demonstrate the changes of ovarian aging markers across the Stages of Reproductive Aging Workshop (STRAW) stages and modify it with subclassification of mid reproductive age stage (MR). Healthy females were classified according to the STRAW system. Serum basal FSH, LH, E2, and anti-Müllerian hormone (AMH) were detected, FSH/LH ratio calculated, and antral follicle counts (AFCs) determined in follicular phase. Progression through the whole STRAW stages under MR stage subdivided is associated with elevations in FSH, LH, FSH/LH ratio and decreases in E2, AMH and AFCs (p age in MR stage. 0.982 ng/ml AMH and 3 antral follicles (low level of MR 25-30 years) were set as cutoffs to distinguish MR stage into early mid reproductive age (EMR) and late mid reproductive age (LMR) stages. The women in EMR stage compared with LMR could retrieve more oocytes in IVF treatment (p stage, demonstrating disparate reproductive aging period with reduced ovarian reserve in young age across the STRAW stages.

  5. Stokes image reconstruction for two-color microgrid polarization imaging systems.

    Science.gov (United States)

    Lemaster, Daniel A

    2011-07-18

    The Air Force Research Laboratory has developed a new microgrid polarization imaging system capable of simultaneously reconstructing linear Stokes parameter images in two colors on a single focal plane array. In this paper, an effective method for extracting Stokes images is presented for this type of camera system. It is also shown that correlations between the color bands can be exploited to significantly increase overall spatial resolution. Test data is used to show the advantages of this approach over bilinear interpolation. The bounds (in terms of available reconstruction bandwidth) on image resolution are also provided.

  6. Dual-mode photoacoustic and ultrasound system for real-time in-vivo ovarian cancer imaging

    Science.gov (United States)

    Mostafa, Atahar; Nandy, Sreyankar; Amidi, Eghbal; Zhu, Quing

    2018-02-01

    More than 80% of the ovarian cancers are diagnosed at late stages and the survival rate is less than 50%. Currently, there is no effective screening technique available and transvaginal US can only tell if the ovaries are enlarged or not. We have developed a new real-time co-registered US and photoacoustic system for in vivo imaging and characterization of ovaries. US is used to localize ovaries and photoacoustic imaging provides functional information about ovarian tissue angiogenesis and oxygenation saturation. The system consists of a tunable laser and a commercial US system from Alpinion Inc. The Alpinion system is cable of providing channel data for both US pulse-echo and photoacoustic imaging and can be programmed as a computer terminal for display US and photoacoustic images side by side or in coregistered mode. A transvaginal ultrasound probe of 6-MHz center frequency and bandwidth of 3-10 MHz is coupled with four optical fibers surrounded the US probe to deliver the light to tissue. The light from optical fibers is homogenized to ensure the power delivered to the tissue surface is below the FDA required limit. Physicians can easily navigate the probe and use US to look for ovaries and then turn on photoacoustic mode to provide real-time tumor vasculature and So2 saturation maps. With the optimized system, we have successfully imaged first group of 7 patients of malignant, abnormal and benign ovaries. The results have shown that both photoacoustic signal strength and spatial distribution are different between malignant and abnormal and benign ovaries.

  7. High dynamic range coding imaging system

    Science.gov (United States)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  8. A compact imaging spectroscopic system for biomolecular detections on plasmonic chips.

    Science.gov (United States)

    Lo, Shu-Cheng; Lin, En-Hung; Wei, Pei-Kuen; Tsai, Wan-Shao

    2016-10-17

    In this study, we demonstrate a compact imaging spectroscopic system for high-throughput detection of biomolecular interactions on plasmonic chips, based on a curved grating as the key element of light diffraction and light focusing. Both the curved grating and the plasmonic chips are fabricated on flexible plastic substrates using a gas-assisted thermal-embossing method. A fiber-coupled broadband light source and a camera are included in the system. Spectral resolution within 1 nm is achieved in sensing environmental index solutions and protein bindings. The detected sensitivities of the plasmonic chip are comparable with a commercial spectrometer. An extra one-dimensional scanning stage enables high-throughput detection of protein binding on a designed plasmonic chip consisting of several nanoslit arrays with different periods. The detected resonance wavelengths match well with the grating equation under an air environment. Wavelength shifts between 1 and 9 nm are detected for antigens of various concentrations binding with antibodies. A simple, mass-productive and cost-effective method has been demonstrated on the imaging spectroscopic system for real-time, label-free, highly sensitive and high-throughput screening of biomolecular interactions.

  9. Imaging system

    International Nuclear Information System (INIS)

    Froggatt, R.J.

    1981-01-01

    The invention provides a two dimensional imaging system in which a pattern of radiation falling on the system is detected to give electrical signals for each of a plurality of strips across the pattern. The detection is repeated for different orientations of the strips and the whole processed by compensated back projection. For a shadow x-ray system a plurality of strip x-ray detectors are rotated on a turntable. For lower frequencies the pattern may be rotated with a Dove prism and the strips condensed to suit smaller detectors with a cylindrical lens. (author)

  10. Comparison of four staging systems of lymph node metastasis in gastric cancer.

    Science.gov (United States)

    Zhang, Ming; Zhu, Guanyu; Ma, Yan; Xue, Yingwei

    2009-11-01

    The classification of lymph node metastasis in patients with gastric cancer is still controversial. Our aim was to evaluate the relative merits of four staging systems of lymph node metastasis. In our study, the nodal status was classified according to the 5th edition of the tumor node metastasis (TNM) system, the Japanese Classification of Gastric Carcinoma (JCGC), the ratio of metastatic lymph nodes, and the size of the largest metastatic lymph node. Each staging system was scored as good (+2), fair (+1), or poor (0) with respect to the theoretical value (extent of the anatomical lymphatic tumor spread), convenience (simplicity), surgical applicability (extent of lymph node dissection), and prognostic value (ability to predict survival rate). In the multivariate analysis including the four staging systems and other potential prognostic factors, stepwise Cox regression revealed that the ratio of metastatic lymph nodes was the most independent prognostic factor. The TNM, ratio, and size systems were convenient because they had no consideration for the location of the tumor and lymph node. Although the JCGC system had advantages in theoretical value and surgical application, it was most optional due to the complexity of the system. Although all different staging systems are comparable, the metastatic lymph node ratio system is convenient, reproducible, and has the highest ability to predict survival.

  11. Multi-stage robust scheme for citrus identification from high resolution airborne images

    Science.gov (United States)

    Amorós-López, Julia; Izquierdo Verdiguier, Emma; Gómez-Chova, Luis; Muñoz-Marí, Jordi; Zoilo Rodríguez-Barreiro, Jorge; Camps-Valls, Gustavo; Calpe-Maravilla, Javier

    2008-10-01

    Identification of land cover types is one of the most critical activities in remote sensing. Nowadays, managing land resources by using remote sensing techniques is becoming a common procedure to speed up the process while reducing costs. However, data analysis procedures should satisfy the accuracy figures demanded by institutions and governments for further administrative actions. This paper presents a methodological scheme to update the citrus Geographical Information Systems (GIS) of the Comunidad Valenciana autonomous region, Spain). The proposed approach introduces a multi-stage automatic scheme to reduce visual photointerpretation and ground validation tasks. First, an object-oriented feature extraction process is carried out for each cadastral parcel from very high spatial resolution (VHR) images (0.5m) acquired in the visible and near infrared. Next, several automatic classifiers (decision trees, multilayer perceptron, and support vector machines) are trained and combined to improve the final accuracy of the results. The proposed strategy fulfills the high accuracy demanded by policy makers by means of combining automatic classification methods with visual photointerpretation available resources. A level of confidence based on the agreement between classifiers allows us an effective management by fixing the quantity of parcels to be reviewed. The proposed methodology can be applied to similar problems and applications.

  12. {sup 18}F-FDG-PET/CT for systemic staging of patients with newly diagnosed ER-positive and HER2-positive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ulaner, Gary A.; Castillo, Raychel [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Wills, Jonathan [Memorial Sloan Kettering Cancer Center, Department of Information Systems, New York, NY (United States); Goenen, Mithat; Goldman, Debra A. [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States)

    2017-08-15

    This study assesses {sup 18}F-FDG-PET/CT for patients with newly diagnosed estrogen receptor-positive/human epidermal growth factor receptor-negative (ER+/HER2-) and human epidermal growth factor receptor-positive (HER2+) breast cancer. In this Institutional Review Board-approved retrospective study, our Healthcare Information System was screened for patients with ER+/HER2- and HER2+ breast cancer who underwent {sup 18}F-FDG-PET/CT prior to systemic or radiation therapy. The initial stage was determined from mammography, ultrasound, magnetic resonance imaging, and/or surgery.{sup 18}F-FDG-PET/CT was evaluated to identify unsuspected extra-axillary regional nodal and distant metastases. The proportion of patients upstaged overall and stratified by stage and receptor phenotypes was calculated along with confidence intervals (CI). A total of 238 patients with ER+/HER2- and 245 patients with HER2+ who met inclusion criteria were evaluated. For patients with ER+/HER2-breast cancer, {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 3/71 (4%) initial stage IIA, 13/95 (14%) stage IIB, and 15/57 (26%) stage III. For patients with HER2+ breast cancer, {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 3/72 (4%) initial stage IIA, 13/93 (14%) stage IIB, and 13/59 (22%) stage III. The overall upstaging rate for IIB was 14% (95% confidence interval (CI): 9-20%). {sup 18}F-FDG-PET/CT revealed distant metastases in 14% (95% CI: 9-20%) of patients with stage IIB ER+/HER2- and HER2+ breast cancer, which is similar to upstaging rates previously seen in patients with stage IIB triple-negative breast cancer (15%, 95% CI: 9-24%). The detection of unsuspected distant metastases in these patients alters treatment and prognosis. NCCN guidelines should consider adding patients with stage IIB breast cancer for consideration of systemic staging with {sup 18}F-FDG-PET/CT at the time of initial diagnosis. (orig.)

  13. Image registration for a UV-Visible dual-band imaging system

    Science.gov (United States)

    Chen, Tao; Yuan, Shuang; Li, Jianping; Xing, Sheng; Zhang, Honglong; Dong, Yuming; Chen, Liangpei; Liu, Peng; Jiao, Guohua

    2018-06-01

    The detection of corona discharge is an effective way for early fault diagnosis of power equipment. UV-Visible dual-band imaging can detect and locate corona discharge spot at all-weather condition. In this study, we introduce an image registration protocol for this dual-band imaging system. The protocol consists of UV image denoising and affine transformation model establishment. We report the algorithm details of UV image preprocessing, affine transformation model establishment and relevant experiments for verification of their feasibility. The denoising algorithm was based on a correlation operation between raw UV images, a continuous mask and the transformation model was established by using corner feature and a statistical method. Finally, an image fusion test was carried out to verify the accuracy of affine transformation model. It has proved the average position displacement error between corona discharge and equipment fault at different distances in a 2.5m-20 m range are 1.34 mm and 1.92 mm in the horizontal and vertical directions, respectively, which are precise enough for most industrial applications. The resultant protocol is not only expected to improve the efficiency and accuracy of such imaging system for locating corona discharge spot, but also supposed to provide a more generalized reference for the calibration of various dual-band imaging systems in practice.

  14. An Ibm PC/AT-Based Image Acquisition And Processing System For Quantitative Image Analysis

    Science.gov (United States)

    Kim, Yongmin; Alexander, Thomas

    1986-06-01

    In recent years, a large number of applications have been developed for image processing systems in the area of biological imaging. We have already finished the development of a dedicated microcomputer-based image processing and analysis system for quantitative microscopy. The system's primary function has been to facilitate and ultimately automate quantitative image analysis tasks such as the measurement of cellular DNA contents. We have recognized from this development experience, and interaction with system users, biologists and technicians, that the increasingly widespread use of image processing systems, and the development and application of new techniques for utilizing the capabilities of such systems, would generate a need for some kind of inexpensive general purpose image acquisition and processing system specially tailored for the needs of the medical community. We are currently engaged in the development and testing of hardware and software for a fairly high-performance image processing computer system based on a popular personal computer. In this paper, we describe the design and development of this system. Biological image processing computer systems have now reached a level of hardware and software refinement where they could become convenient image analysis tools for biologists. The development of a general purpose image processing system for quantitative image analysis that is inexpensive, flexible, and easy-to-use represents a significant step towards making the microscopic digital image processing techniques more widely applicable not only in a research environment as a biologist's workstation, but also in clinical environments as a diagnostic tool.

  15. Multispectral imaging for biometrics

    Science.gov (United States)

    Rowe, Robert K.; Corcoran, Stephen P.; Nixon, Kristin A.; Ostrom, Robert E.

    2005-03-01

    Automated identification systems based on fingerprint images are subject to two significant types of error: an incorrect decision about the identity of a person due to a poor quality fingerprint image and incorrectly accepting a fingerprint image generated from an artificial sample or altered finger. This paper discusses the use of multispectral sensing as a means to collect additional information about a finger that significantly augments the information collected using a conventional fingerprint imager based on total internal reflectance. In the context of this paper, "multispectral sensing" is used broadly to denote a collection of images taken under different polarization conditions and illumination configurations, as well as using multiple wavelengths. Background information is provided on conventional fingerprint imaging. A multispectral imager for fingerprint imaging is then described and a means to combine the two imaging systems into a single unit is discussed. Results from an early-stage prototype of such a system are shown.

  16. 11C-acetate for positron emission tomography imaging of clinical stage IA lung adenocarcinoma. Comparison with 18F-fluorodeoxyglucose for imaging and evaluation of tumor aggressiveness

    International Nuclear Information System (INIS)

    Shibata, Hidekatsu; Nomori, Hiroaki; Uno, Kimiichi

    2009-01-01

    To determine the usefulness of positron emission tomography (PET) with 11 C-acetate (AC) for imaging lung adenocarcinoma and evaluating its tumor aggressiveness, AC- and 18 F-fluorodeoxyglucose (FDG)-PET were compared. One hundred and sixty-nine adenocarcinomas with clinical stage IA and 53 benign nodules were examined by both AC- and FDG-PET before surgery. The sensitivity and specificity for discriminating benign/adenocarcinoma were compared between AC- and FDG-PET. The AC and FDG uptakes were examined to determine the relationship with tumor aggressiveness, id est (i.e.), pathological tumor stage, lymphatic, vascular, or pleural involvement, and proliferative activity determined by Ki-67 staining score. While the sensitivity of AC-PET was significantly higher than FDG-PET for bronchioloalveolar carcinoma (BAC) and well-differentiated (W/D) adenocarcinoma (p<0.001 and 0.006, respectively), there was no significant difference for moderately or poorly differentiated adenocarcinoma. The specificity was not different between them. While FDG uptakes were significantly higher in tumors with pathological advanced stages or those with lymphatic, vascular and/or pleural involvements than in tumors with pathological stage IA or those without these tumor involvements (p=0.04 to p<0.001), AC uptake did not show significant differences between the respective sub-groups except according to the tumor stage. While both AC and FDG uptakes showed a significant correlation with Ki-67 staining scores (p=0.03 and p<0.001, respectively), the correlation coefficient of former was lower than that of latter (p=0.07). While AC-PET can image BAC and W/D adenocarcinoma with a higher sensitivity than FDG-PET, it cannot evaluate tumor aggressiveness of clinical stage IA lung adenocarcinoma as well as FDG-PET. (author)

  17. Raster images vectorization system

    OpenAIRE

    Genytė, Jurgita

    2006-01-01

    The problem of raster images vectorization was analyzed and researched in this work. Existing vectorization systems are quite expensive, the results are inaccurate, and the manual vectorization of a large number of drafts is impossible. That‘s why our goal was to design and develop a new raster images vectorization system using our suggested automatic vectorization algorithm and the way to record results in a new universal vectorial file format. The work consists of these main parts: analysis...

  18. Stages in the energetics of baroclinic systems

    Science.gov (United States)

    Orlanski, Isidoro; Sheldon, John P.

    1995-10-01

    The results from several idealized and case studies are drawn together to form a comprehensive picture of "downstream baroclinic evolution" using local energetics. This new viewpoint offers a complementary alternative to the more conventional descriptions of cyclone development. These additional insights are made possible largely because the local energetics approach permits one to define an energy flux vector which accurately describes the direction of energy dispersion and quantifies the role of neighboring systems in local development. In this view, the development of a system's energetics is divided into three stages. In Stage 1, a pre-existing disturbance well upstream of an incipient trough loses energy via ageostrophic geopotential fluxes directed downstream through the intervening ridge, generating a new energy center there. In Stage 2, this new energy center grows vigorously, at first due to the convergence of these fluxes, and later by baroclinic conversion as well. As the center matures, it begins to export energy via geopotential fluxes to the eastern side of the trough, initiating yet another energy center. In Stage 3, this new energy center continues to grow while that on the western side of the trough decays due to a dwinding supply of energy via fluxes from the older upstream system and also as a consequence of its own export of energy downstream. As the eastern energy center matures, it exports energy further downstream, and the sequence begins anew. The USA "Blizzard of'93" is used as a new case study to test the limits to which this conceptual sequence might apply, as well as to augment the current limited set of case studies. It is shown that, despite the extraordinary magnitude of the event, the evolution of the trough associated with the Blizzard fits the conceptual picture of downstream baroclinic evolution quite well, with geopotential fluxes playing a critical rôle in three respects. First, fluxes from an old, decaying system in the

  19. Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on-board imager and electronic portal imaging device imaging systems.

    Science.gov (United States)

    Gao, Song; Du, Weiliang; Balter, Peter; Munro, Peter; Jeung, Andrew

    2014-05-08

    The purpose of this study is to evaluate the accuracy and reproducibility of the IsoCal geometric calibration system for kilovoltage (kV) and megavoltage (MV) imagers on Varian C-series linear accelerators (linacs). IsoCal calibration starts by imaging a phantom and collimator plate using MV images with different collimator angles, as well as MV and kV images at different gantry angles. The software then identifies objects on the collimator plate and in the phantom to determine the location of the treatment isocenter and its relation to the MV and kV imager centers. It calculates offsets between the positions of the imaging panels and the treatment isocenter as a function of gantry angle and writes a correction file that can be applied to MV and kV systems to correct for those offsets in the position of the panels. We performed IsoCal calibration three times on each of five Varian C-series linacs, each time with an independent setup. We then compared the IsoCal calibrations with a simplified Winston-Lutz (WL)-based system and with a Varian cubic phantom (VC)-based system. The maximum IsoCal corrections ranged from 0.7 mm to 1.5 mm for MV and 0.9 mm to 1.8 mm for kV imagers across the five linacs. The variations in the three calibrations for each linac were less than 0.2 mm. Without IsoCal correction, the WL results showed discrepancies between the treatment isocenter and the imager center of 0.9 mm to 1.6 mm (for the MV imager) and 0.5 mm to 1.1 mm (for the kV imager); with IsoCal corrections applied, the differences were reduced to 0.2 mm to 0.6 mm (MV) and 0.3 mm to 0.6 mm (kV) across the five linacs. The VC system was not as precise as the WL system, but showed similar results, with discrepancies of less than 1.0 mm when the IsoCal corrections were applied. We conclude that IsoCal is an accurate and consistent method for calibration and periodic quality assurance of MV and kV imaging systems.

  20. A web-based Tamsui River flood early-warning system with correction of real-time water stage using monitoring data

    Science.gov (United States)

    Liao, H. Y.; Lin, Y. J.; Chang, H. K.; Shang, R. K.; Kuo, H. C.; Lai, J. S.; Tan, Y. C.

    2017-12-01

    Taiwan encounters heavy rainfalls frequently. There are three to four typhoons striking Taiwan every year. To provide lead time for reducing flood damage, this study attempt to build a flood early-warning system (FEWS) in Tanshui River using time series correction techniques. The predicted rainfall is used as the input for the rainfall-runoff model. Then, the discharges calculated by the rainfall-runoff model is converted to the 1-D river routing model. The 1-D river routing model will output the simulating water stages in 487 cross sections for the future 48-hr. The downstream water stage at the estuary in 1-D river routing model is provided by storm surge simulation. Next, the water stages of 487 cross sections are corrected by time series model such as autoregressive (AR) model using real-time water stage measurements to improve the predicted accuracy. The results of simulated water stages are displayed on a web-based platform. In addition, the models can be performed remotely by any users with web browsers through a user interface. The on-line video surveillance images, real-time monitoring water stages, and rainfalls can also be shown on this platform. If the simulated water stage exceeds the embankments of Tanshui River, the alerting lights of FEWS will be flashing on the screen. This platform runs periodically and automatically to generate the simulation graphic data of flood water stages for flood disaster prevention and decision making.

  1. Nasopharyngeal carcinoma: comparison of diffusion and perfusion characteristics between different tumour stages using intravoxel incoherent motion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Vincent; Li, Xiao; Huang, Bingsheng; Khong, Pek Lan [University of Hong Kong, Queen Mary Hospital, Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, Hong Kong (China); Lee, Victor Ho Fun; Lam, Ka On [University of Hong Kong, Queen Mary Hospital, Department of Clinical Oncology, Li Ka Shing Faculty of Medicine, Hong Kong (China); Fong, Daniel Yee Tak [University of Hong Kong, School of Nursing, Li Ka Shing Faculty of Medicine, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong, New Territories (China)

    2014-01-15

    To explore intravoxel incoherent motion (IVIM) characteristics of nasopharyngeal carcinoma (NPC) and relationships with different tumour stages. We prospectively recruited 80 patients with newly diagnosed undifferentiated NPC. Diffusion-weighted MR imaging was performed and IVIM parameters (D, pure diffusion; f, perfusion fraction; D*, pseudodiffusion coefficient) were calculated. Patients were stratified into low and high tumour stage groups based on American Joint Committee on Cancer (AJCC) and TNM staging for determination of the predictive powers of IVIM parameters using t test, multiple logistic regression and ROC curve analyses. D, f and D* were all statistically significantly lower in high-stage groups in AJCC, T and N staging. D, f and D* were all independent predictors of AJCC staging, f and D* were independent predictors of T staging, and D was an independent predictor of N staging. D was most powerful for AJCC and N staging, whereas f was most powerful for T staging. Optimal cut-off values (area under the curve, sensitivity, specificity, positive likelihood ratio, negative likelihood ratio) were as follows: AJCC stage, D = 0.782 x 10{sup -3} mm{sup 2}/s (0.915, 93.3 %, 76.2 %, 3.92, 0.09); T staging, f = 0.133 (0.905, 80.5 %, 92.5 %, 10.73, 0.21); N staging, D = 0.761 x 10{sup -3} mm{sup 2}/s (0.848, 87.5 %, 66.7 %, 2.62, 0.19). Multivariate analysis showed no diagnostic improvement. Nasopharyngeal carcinoma has distinctive intravoxel incoherent motion characteristics parameters in different tumour staging, potentially helping pretreatment staging. (orig.)

  2. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  3. Hologlyphics: volumetric image synthesis performance system

    Science.gov (United States)

    Funk, Walter

    2008-02-01

    This paper describes a novel volumetric image synthesis system and artistic technique, which generate moving volumetric images in real-time, integrated with music. The system, called the Hologlyphic Funkalizer, is performance based, wherein the images and sound are controlled by a live performer, for the purposes of entertaining a live audience and creating a performance art form unique to volumetric and autostereoscopic images. While currently configured for a specific parallax barrier display, the Hologlyphic Funkalizer's architecture is completely adaptable to various volumetric and autostereoscopic display technologies. Sound is distributed through a multi-channel audio system; currently a quadraphonic speaker setup is implemented. The system controls volumetric image synthesis, production of music and spatial sound via acoustic analysis and human gestural control, using a dedicated control panel, motion sensors, and multiple musical keyboards. Music can be produced by external acoustic instruments, pre-recorded sounds or custom audio synthesis integrated with the volumetric image synthesis. Aspects of the sound can control the evolution of images and visa versa. Sounds can be associated and interact with images, for example voice synthesis can be combined with an animated volumetric mouth, where nuances of generated speech modulate the mouth's expressiveness. Different images can be sent to up to 4 separate displays. The system applies many novel volumetric special effects, and extends several film and video special effects into the volumetric realm. Extensive and various content has been developed and shown to live audiences by a live performer. Real world applications will be explored, with feedback on the human factors.

  4. 3D images and expert system

    International Nuclear Information System (INIS)

    Hasegawa, Jun-ichi

    1998-01-01

    This paper presents an expert system called 3D-IMPRESS for supporting applications of three dimensional (3D) image processing. This system can automatically construct a 3D image processing procedure based on a pictorial example of the goal given by a user. In the paper, to evaluate the performance of the system, it was applied to construction of procedures for extracting specific component figures from practical chest X-ray CT images. (author)

  5. Liver fibrosis detection and staging: a comparative study of T1ρ MR imaging and 2D real-time shear-wave elastography.

    Science.gov (United States)

    Li, Ruo-Kun; Ren, Xin-Pin; Yan, Fu-Hua; Qiang, Jin-Wei; Lin, Hui-Min; Tao Wang; Zhao, Hong-Fei; Chen, Wei-Bo

    2017-12-02

    To compare the results of T1ρ MR imaging and 2D real-time shear-wave elastography (SWE) for liver fibrosis detection and staging. Twenty-nine rabbit models of CCl 4 -induced liver fibrosis were established and six untreated rabbits served as controls. T1ρ MR imaging and 2D real-time SWE examination were performed at 2, 4, 6, 8, 10, and 12 weeks. T1ρ values and liver stiffness (LS) values were measured. Fibrosis was staged according to the METAVIR scoring system. Correlation test was performed among T1ρ values, LS values, and fibrosis stage. Receiver operating characteristic (ROC) analysis was performed for assessing diagnostic performance of T1ρ and SWE in detection of no fibrosis (F0), substantial fibrosis (≥ F2), severe fibrosis (≥ F3), and cirrhosis (F4). There was moderate positive correlation between fibrosis stage and T1ρ values (r = 0.566; 95% CI 0.291-0.754; P < 0.0001), and LS value (r = 0.726; 95% CI 0.521-0.851; P = 0.003). T1ρ values showed moderate positive correlations with LS values [r = 0.693; 95% confidence interval (CI) 0.472-0.832; P < 0.0001]. Areas Under ROC (AUROCs) were 0.861 (95% CI 0.705-0.953) for SWE and 0.856 (95% CI 0.698-0.950) for T1ρ (P = 0.940), 0.906 (95% CI 0.762-0.978) for SWE and 0.849 (95% CI 0.691-0.946) for T1ρ (P = 0.414), 0.870 (95% CI 0.716-0.958) for SWE and 0.799 (95% CI 0.632-0.913) for T1ρ (P = 0.422), and 0.846 (95% CI 0.687-0.944) for SWE and 0.692 (95% CI 0.517-0.835) for T1ρ (P = 0.137), when diagnosing liver fibrosis with ≥ F1, ≥ F2, ≥ F3, and F4, respectively. There was moderate positive correlation between inflammatory activity and T1ρ values (r = 0.520; 95% CI 0.158-0.807; P = 0.013). T1ρ imaging has potential for liver fibrosis detection and staging with good diagnostic capability similar to that of ultrasonography elastography.

  6. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  7. Characterization of lens based photoacoustic imaging system.

    Science.gov (United States)

    Francis, Kalloor Joseph; Chinni, Bhargava; Channappayya, Sumohana S; Pachamuthu, Rajalakshmi; Dogra, Vikram S; Rao, Navalgund

    2017-12-01

    Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  8. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    Science.gov (United States)

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  9. Musashi dynamic image processing system

    International Nuclear Information System (INIS)

    Murata, Yutaka; Mochiki, Koh-ichi; Taguchi, Akira

    1992-01-01

    In order to produce transmitted neutron dynamic images using neutron radiography, a real time system called Musashi dynamic image processing system (MDIPS) was developed to collect, process, display and record image data. The block diagram of the MDIPS is shown. The system consists of a highly sensitive, high resolution TV camera driven by a custom-made scanner, a TV camera deflection controller for optimal scanning, which adjusts to the luminous intensity and the moving speed of an object, a real-time corrector to perform the real time correction of dark current, shading distortion and field intensity fluctuation, a real time filter for increasing the image signal to noise ratio, a video recording unit and a pseudocolor monitor to realize recording in commercially available products and monitoring by means of the CRTs in standard TV scanning, respectively. The TV camera and the TV camera deflection controller utilized for producing still images can be applied to this case. The block diagram of the real-time corrector is shown. Its performance is explained. Linear filters and ranked order filters were developed. (K.I.)

  10. Design of a smartphone-camera-based fluorescence imaging system for the detection of oral cancer

    Science.gov (United States)

    Uthoff, Ross

    Shown is the design of the Smartphone Oral Cancer Detection System (SOCeeDS). The SOCeeDS attaches to a smartphone and utilizes its embedded imaging optics and sensors to capture images of the oral cavity to detect oral cancer. Violet illumination sources excite the oral tissues to induce fluorescence. Images are captured with the smartphone's onboard camera. Areas where the tissues of the oral cavity are darkened signify an absence of fluorescence signal, indicating breakdown in tissue structure brought by precancerous or cancerous conditions. With this data the patient can seek further testing and diagnosis as needed. Proliferation of this device will allow communities with limited access to healthcare professionals a tool to detect cancer in its early stages, increasing the likelihood of cancer reversal.

  11. Cyclops: single-pixel imaging lidar system based on compressive sensing

    Science.gov (United States)

    Magalhães, F.; Correia, M. V.; Farahi, F.; Pereira do Carmo, J.; Araújo, F. M.

    2017-11-01

    Mars and the Moon are envisaged as major destinations of future space exploration missions in the upcoming decades. Imaging LIDARs are seen as a key enabling technology in the support of autonomous guidance, navigation and control operations, as they can provide very accurate, wide range, high-resolution distance measurements as required for the exploration missions. Imaging LIDARs can be used at critical stages of these exploration missions, such as descent and selection of safe landing sites, rendezvous and docking manoeuvres, or robotic surface navigation and exploration. Despite these devices have been commercially available and used for long in diverse metrology and ranging applications, their size, mass and power consumption are still far from being suitable and attractive for space exploratory missions. Here, we describe a compact Single-Pixel Imaging LIDAR System that is based on a compressive sensing technique. The application of the compressive codes to a DMD array enables compression of the spatial information, while the collection of timing histograms correlated to the pulsed laser source ensures image reconstruction at the ranged distances. Single-pixel cameras have been compared with raster scanning and array based counterparts in terms of noise performance, and proved to be superior. Since a single photodetector is used, a better SNR and higher reliability is expected in contrast with systems using large format photodetector arrays. Furthermore, the event of failure of one or more micromirror elements in the DMD does not prevent full reconstruction of the images. This brings additional robustness to the proposed 3D imaging LIDAR. The prototype that was implemented has three modes of operation. Range Finder: outputs the average distance between the system and the area of the target under illumination; Attitude Meter: provides the slope of the target surface based on distance measurements in three areas of the target; 3D Imager: produces 3D ranged

  12. Influence of dispatching rules on average production lead time for multi-stage production systems.

    Science.gov (United States)

    Hübl, Alexander; Jodlbauer, Herbert; Altendorfer, Klaus

    2013-08-01

    In this paper the influence of different dispatching rules on the average production lead time is investigated. Two theorems based on covariance between processing time and production lead time are formulated and proved theoretically. Theorem 1 links the average production lead time to the "processing time weighted production lead time" for the multi-stage production systems analytically. The influence of different dispatching rules on average lead time, which is well known from simulation and empirical studies, can be proved theoretically in Theorem 2 for a single stage production system. A simulation study is conducted to gain more insight into the influence of dispatching rules on average production lead time in a multi-stage production system. We find that the "processing time weighted average production lead time" for a multi-stage production system is not invariant of the applied dispatching rule and can be used as a dispatching rule independent indicator for single-stage production systems.

  13. LOX/LH2 propulsion system for launch vehicle upper stage, test results

    Science.gov (United States)

    Ikeda, T.; Imachi, U.; Yuzawa, Y.; Kondo, Y.; Miyoshi, K.; Higashino, K.

    1984-01-01

    The test results of small LOX/LH2 engines for two propulsion systems, a pump fed system and a pressure fed system are reported. The pump fed system has the advantages of higher performances and higher mass fraction. The pressure fed system has the advantages of higher reliability and relative simplicity. Adoption of these cryogenic propulsion systems for upper stage of launch vehicle increases the payload capability with low cost. The 1,000 kg thrust class engine was selected for this cryogenic stage. A thrust chamber assembly for the pressure fed propulsion system was tested. It is indicated that it has good performance to meet system requirements.

  14. Stages as models of scene geometry.

    Science.gov (United States)

    Nedović, Vladimir; Smeulders, Arnold W M; Redert, André; Geusebroek, Jan-Mark

    2010-09-01

    Reconstruction of 3D scene geometry is an important element for scene understanding, autonomous vehicle and robot navigation, image retrieval, and 3D television. We propose accounting for the inherent structure of the visual world when trying to solve the scene reconstruction problem. Consequently, we identify geometric scene categorization as the first step toward robust and efficient depth estimation from single images. We introduce 15 typical 3D scene geometries called stages, each with a unique depth profile, which roughly correspond to a large majority of broadcast video frames. Stage information serves as a first approximation of global depth, narrowing down the search space in depth estimation and object localization. We propose different sets of low-level features for depth estimation, and perform stage classification on two diverse data sets of television broadcasts. Classification results demonstrate that stages can often be efficiently learned from low-dimensional image representations.

  15. The image acquisition system design of floor grinder

    Science.gov (United States)

    Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin

    2018-01-01

    Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.

  16. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  17. Confocal microlaparoscope for imaging the fallopian tube

    Science.gov (United States)

    Wu, Tzu-Yu; Rouse, Andrew R.; Chambers, Setsuko K.; Hatch, Kenneth D.; Gmitro, Arthur F.

    2014-11-01

    Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.

  18. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  19. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  20. AN ENSEMBLE TEMPLATE MATCHING AND CONTENT-BASED IMAGE RETRIEVAL SCHEME TOWARDS EARLY STAGE DETECTION OF MELANOMA

    Directory of Open Access Journals (Sweden)

    Spiros Kostopoulos

    2016-12-01

    Full Text Available Malignant melanoma represents the most dangerous type of skin cancer. In this study we present an ensemble classification scheme, employing the mutual information, the cross-correlation and the clustering based on proximity of image features methods, for early stage assessment of melanomas on plain photography images. The proposed scheme performs two main operations. First, it retrieves the most similar, to the unknown case, image samples from an available image database with verified benign moles and malignant melanoma cases. Second, it provides an automated estimation regarding the nature of the unknown image sample based on the majority of the most similar images retrieved from the available database. Clinical material comprised 75 melanoma and 75 benign plain photography images collected from publicly available dermatological atlases. Results showed that the ensemble scheme outperformed all other methods tested in terms of accuracy with 94.9±1.5%, following an external cross-validation evaluation methodology. The proposed scheme may benefit patients by providing a second opinion consultation during the self-skin examination process and the physician by providing a second opinion estimation regarding the nature of suspicious moles that may assist towards decision making especially for ambiguous cases, safeguarding, in this way from potential diagnostic misinterpretations.

  1. Noninvasive staging of lung cancer. Indications and limitations of gallium-67 citrate imaging

    International Nuclear Information System (INIS)

    Bekerman, C.; Caride, V.J.; Hoffer, P.B.; Boles, C.A.

    1990-01-01

    The results of evaluation of the hila and mediastinum with 67Ga scans are contradictory, as are the recommendations by different investigators on the use of 67Ga scintigraphy in the clinical evaluation of patients with primary lung carcinoma. Nevertheless, the economy and logistic simplicity of evaluating local and distant metastases with a single imaging procedure are attractive, especially because the symptoms may not enable the physician to make a correct identification of the organ systems affected by metastases. Neumann and Hoffer state that at present conventional Ga-67 scanning techniques cannot be recommended for preoperative staging of mediastinal lymph node metastases in lung cancer patients. According to Waxman, 67Ga scintigraphy, relative to other imaging modalities, is a sensitive indicator of hilar spread of a tumor. However, because of the normally high background activity within the sternum and spine, mediastinal abnormalities may be poorly detected. Since most pulmonary tumors metastasize via regional nodes to the pulmonary hilum and then to the mediastinum, the high sensitivity for the detection of pulmonary hilar abnormalities and the high specificity for detection of mediastinal lesions suggest that gallium scintigraphy is a valuable adjunctive test when used appropriately. The results obtained locally are probably the best guide for individual physicians in the selection of diagnostic tests for their patients. Gallium scans may thus be helpful in the clinical evaluation of patients with lung cancer. Although gallium scans identify mediastinal node involvement, there is considerable controversy over the relationship between the sensitivity and specificity of the method. By detecting distant extrathoracic metastases, the 67Ga scan may identify a small group of patients who can be spared a needless operation. 92 references

  2. Exploratory survey of image quality on CR digital mammography imaging systems in Mexico

    International Nuclear Information System (INIS)

    Gaona, E.; Rivera, T.; Arreola, M.; Franco, J.; Molina, N.; Alvarez, B.; Azorín, C.G.; Casian, G.

    2014-01-01

    The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation. - Highlights: • Radiation dose in CR digital mammography (CRDM) systems was determined. • Image quality related with dose in CR digital mammography (CRDM) systems was analysed. • Image processing artefacts were observed and correlated with dose. • Measured entrance dose by TL phosphors could be good parameter for radiation protection optimization in patient

  3. Developments of optical fast-gated imaging systems

    International Nuclear Information System (INIS)

    Koehler, H.A.; Kotecki, D.

    1984-08-01

    Several fast-gated imaging systems to measure ultra-fast single-transient data have been developed for time-resolved imaging of pulsed radiation sources. These systems were designed to achieve image recording times of 1 to 3 ms and dynamic ranges of >200:1 to produce large two-dimensional images (greater than or equal to 10 4 spatial points) of 1 to 2 ns exposure and small two-dimensional images (less than or equal to 200 spatial points) of less than or equal to 0.5 ns exposure. Both MCP intensified solid-state two-dimensional framing cameras and streak camera/solid-state camera systems were used; the framing camera system provides snap shots with high spatial resolution whereas the streak camera system provides for limited spatial points each with high temporal resolution. Applications of these systems include electron-beam, x-ray, gamma-ray, and neutron diagnostics. This report reviews the characteristics of the major components of fast-gated imaging systems developed at Lawrence Livermore National Laboratory. System performances are described in view of major experiments, and the diagnostic requirements of new experiments in atomic physics (x-ray lasers) and nuclear physics (fusion) are indicated

  4. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    Science.gov (United States)

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  5. MR diffusion weighted imaging experimental study on early stages of articular cartilage degeneration of knee

    International Nuclear Information System (INIS)

    Dai Jingru; Dai Shipeng; Pang Jun; Xu Xiaokun; Wang Yuexin; Zhang Zhigang

    2008-01-01

    Objective: To study the appearance of MR diffusion weighted imaging in early stages of cartilage degeneration and to detect its values. Methods: In 20 goat left knees, intra- articular injection of 5 units of papain was performed causing a loss of cartilage proteoglycan. Twenty right knees were used as control group. MR diffusion weighted imaging was performed at 24 hours after intra-articular injection of papain. ADC of each part of articular cartilage was measured and compared with each other. The proteoglycan content was measured biochemically and histochemically. Routine MRI and DWI were performed in 100 patients with osteoarthritis and 20 healthy people. The ADC of each interested part of articular cartilage was measured and compared with each other. Results: In experimental control group, the ADCav of articular cartilage was (14.2±2.3) x 10 -4 mm 2 /s. In early stages of cartilage degeneration group, the ADCav of articular cartilage was (17.5±4.2) x 10 -4 mm 2 /s. The ADCav of the control group was lower than that of the early stages of cartilage degeneration group (t=2.709; P=0.016). The proteloglycan content of articular cartilage was 4.22 x 10 6 μg/kg in control group, and 0.82 x 10 6 μg/kg in experimental group at 24 hours after injection of papain. The difference between control group and experimental group was significant (t=2.705, P=0.018). In healthy people, the ADCav of articular cartilage was (7.6±2.2) x 10 -4 mm 2 /s. In osteoarthritis group, the ADCav of articular cartilage was (10.3±4.2) x 10 -4 mm 2 /s. The ADCav in the healthy group was significantly lower than that in the osteoarthritis group (t=2.609,P=0.014). Conclusion: DWI is an useful method in detecting early stages of cartilage degeneration which can not be showed on routine sequences. (authors)

  6. Content Based Retrieval System for Magnetic Resonance Images

    International Nuclear Information System (INIS)

    Trojachanets, Katarina

    2010-01-01

    The amount of medical images is continuously increasing as a consequence of the constant growth and development of techniques for digital image acquisition. Manual annotation and description of each image is impractical, expensive and time consuming approach. Moreover, it is an imprecise and insufficient way for describing all information stored in medical images. This induces the necessity for developing efficient image storage, annotation and retrieval systems. Content based image retrieval (CBIR) emerges as an efficient approach for digital image retrieval from large databases. It includes two phases. In the first phase, the visual content of the image is analyzed and the feature extraction process is performed. An appropriate descriptor, namely, feature vector is then associated with each image. These descriptors are used in the second phase, i.e. the retrieval process. With the aim to improve the efficiency and precision of the content based image retrieval systems, feature extraction and automatic image annotation techniques are subject of continuous researches and development. Including the classification techniques in the retrieval process enables automatic image annotation in an existing CBIR system. It contributes to more efficient and easier image organization in the system.Applying content based retrieval in the field of magnetic resonance is a big challenge. Magnetic resonance imaging is an image based diagnostic technique which is widely used in medical environment. According to this, the number of magnetic resonance images is enormously growing. Magnetic resonance images provide plentiful medical information, high resolution and specific nature. Thus, the capability of CBIR systems for image retrieval from large database is of great importance for efficient analysis of this kind of images. The aim of this thesis is to propose content based retrieval system architecture for magnetic resonance images. To provide the system efficiency, feature

  7. NxStage dialysis system-associated thrombocytopenia: a report of two cases.

    Science.gov (United States)

    Sekkarie, Mohamed; Waldron, Michelle; Reynolds, Texas

    2016-01-01

    Thrombocytopenia in hemodialysis patients has recently been reported to be commonly caused by electron-beam sterilization of dialysis filters. We report the occurrence of thrombocytopenia in the first two patients of a newly established home hemodialysis program. The 2 patients switched from conventional hemodialysis using polysulfone electron-beam sterilized dialyzers to a NxStage system, which uses gamma sterilized polyehersulfone dialyzers incorporated into a drop-in cartridge. The thrombocytopenia resolved after return to conventional dialysis in both patients and recurred upon rechallenge in the patient who opted to retry NxStage. This is the first report of thrombocytopenia with the NxStage system according to the authors’ knowledge. Dialysis-associated thrombocytopenia pathophysiology and clinical significance are not well understood and warrant additional investigations.

  8. Musculoskeletal Imaging Findings of Hematologic Malignancies.

    Science.gov (United States)

    Navarro, Shannon M; Matcuk, George R; Patel, Dakshesh B; Skalski, Matthew; White, Eric A; Tomasian, Anderanik; Schein, Aaron J

    2017-01-01

    Hematologic malignancies comprise a set of prevalent yet clinically diverse diseases that can affect every organ system. Because blood components originate in bone marrow, it is no surprise that bone marrow is a common location for both primary and metastatic hematologic neoplasms. Findings of hematologic malignancy can be seen with most imaging modalities including radiography, computed tomography (CT), technetium 99m ( 99m Tc) methylene diphosphonate (MDP) bone scanning, fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, and magnetic resonance (MR) imaging. Because of the diversity of imaging appearances and clinical behavior of this spectrum of disease, diagnosis can be challenging, and profound understanding of the underlying pathophysiologic changes and current treatment modalities can be daunting. The appearance of normal bone marrow at MR imaging and FDG PET/CT is also varied due to dynamic compositional changes with normal aging and in response to hematologic demand or treatment, which can lead to false-positive interpretation of imaging studies. In this article, the authors review the normal maturation and imaging appearance of bone marrow. Focusing on lymphoma, leukemia, and multiple myeloma, they present the spectrum of imaging findings of hematologic malignancy affecting the musculoskeletal system and the current imaging tools available to the radiologist. They discuss the imaging findings of posttreatment bone marrow and review commonly used staging systems and consensus recommendations for appropriate imaging for staging, management, and assessment of clinical remission. © RSNA, 2017.

  9. Development of a secure and cost-effective infrastructure for the access of arbitrary web-based image distribution systems

    International Nuclear Information System (INIS)

    Hacklaender, T.; Demabre, N.; Cramer, B.M.; Kleber, K.; Schneider, H.

    2004-01-01

    Purpose: To build an infrastructure that enables radiologists on-call and external users a teleradiological access to the HTML-based image distribution system inside the hospital via internet. In addition, no investment costs should arise on the user side and the image data should be sent renamed using cryptographic techniques. Materials and Methods: A pure HTML-based system manages the image distribution inside the hospital, with an open source project extending this system through a secure gateway outside the firewall of the hospital. The gateway handles the communication between the external users and the HTML server within the network of the hospital. A second firewall is installed between the gateway and the external users and builds up a virtual private network (VPN). A connection between the gateway and the external user is only acknowledged if the computers involved authenticate each other via certificates and the external users authenticate via a multi-stage password system. All data are transferred encrypted. External users get only access to images that have been renamed to a pseudonym by means of automated processing before. Results: With an ADSL internet access, external users achieve an image load frequency of 0.4 CT images per second. More than 90% of the delay during image transfer results from security checks within the firewalls. Data passing the gateway induce no measurable delay. (orig.)

  10. Mapping the extent of disease by multislice computed tomography, magnetic resonance imaging and sentinel node evaluation in stage I and II cervical carcinoma

    Directory of Open Access Journals (Sweden)

    Rajaram S

    2010-01-01

    Full Text Available Aims: (1 To map the extent of disease in women with stage I and II carcinoma cervix by multislice spiral computed tomography (CT, magnetic resonance imaging (MRI and sentinel nodes. (2 To assess accuracy of each modality individually and in conjunction with FIGO clinical staging. Design and Setting: Prospective, single-blind study. Departments of Obstetrics and Gynaecology, Radiodiagnosis, and Pathology, UCMS and GTBH and Division of Radiological Imaging and Bioinformatics, INMAS, Delhi. Material and Method: The study was conducted on 25 women with cervical cancer FIGO stage I and II. Each woman underwent clinical staging, multislice spiral CT and MRI which was compared to the gold-standard histopathology/cytology. The overall accuracy of each modality and improvement of clinical staging by CT/MRI were noted. Sentinel nodes were evaluated by intracervical Patent Blue V dye injection. Statistical Analysis: Sensitivity, specificity, positive and negative predictive values were calculated by 2Χ2 contingency tables. Results: The accuracy of staging by FIGO, CT and MRI was 68%, 52% and 80%, respectively. MRI and CT improved the overall accuracy of FIGO staging to 96% and 80%, respectively. Sentinel nodes were identified in 89% of patients with 91% accuracy. Conclusion: MRI emerges as the most valuable stand-alone modality improving accuracy of FIGO staging to 96%. Sentinel lymph-node evaluation appears promising in evaluating spread beyond cervix.

  11. Flow imaging of the cardiovascular system using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Imai, Hitoshi; Sakakibara, Makoto; Sunami, Yuko

    1988-01-01

    Blood flow images by magnetic resonance imaging (MRI) using a 0.25 T unit were evaluated for nine normal volunteers and 108 subjects with a variety of cardiovascular abnormalities. Using the non-gated short-spin echo (SE) technique, blood flow in the cardiovascular systems was not imaged in the normal volunteers. Using end-systolic and end-diastolic SE techniques for the normal subjects, blood flow in the cardiac chambers was not clearly imaged. Blood flow in the ascending aorta and aortic arch often did not appear in the gated SE images of the normal subjects. However, blood flow in the descending aorta was often observed in the gated SE images. Blood flow imaging was demonstrated by both non-gated and gated SE techniques in regions where blood flow was relatively slow; for example, in the left atrium of mitral stenosis, in an aortic aneurysm, in a false lumen of an aortic dissection, and in the left ventricle having old myocardial infarction. Using the non-gated inversion recovery (IR) technique, no blood flow was imaged in the cardiovascular system except in the left atrium of one case with mitral stenosis. Using the non-gated short SE technique, there was good correlation between the thrombus formation and the presence of blood flow images in the left atria of 17 patients with mitral stenosis, and in the aneurysmal portions of the aorta or in the false lumens of aortic dissection of 18 patients. It was suggested that mural thrombi in such diseases were related to the relatively slow blood flow. Blood flow imaging easily distinguished stagnant blood flow from mural thrombi using non-gated short SE, end-systolic SE, and IR techniques. Thus, blood flow imaging using MRI should become an important means of evaluating the cardiovascular system. (author)

  12. Development of a hemispherical rotational modulation collimator system for imaging spatial distribution of radiation sources

    Science.gov (United States)

    Na, M.; Lee, S.; Kim, G.; Kim, H. S.; Rho, J.; Ok, J. G.

    2017-12-01

    Detecting and mapping the spatial distribution of radioactive materials is of great importance for environmental and security issues. We design and present a novel hemispherical rotational modulation collimator (H-RMC) system which can visualize the location of the radiation source by collecting signals from incident rays that go through collimator masks. The H-RMC system comprises a servo motor-controlled rotating module and a hollow heavy-metallic hemisphere with slits/slats equally spaced with the same angle subtended from the main axis. In addition, we also designed an auxiliary instrument to test the imaging performance of the H-RMC system, comprising a high-precision x- and y-axis staging station on which one can mount radiation sources of various shapes. We fabricated the H-RMC system which can be operated in a fully-automated fashion through the computer-based controller, and verify the accuracy and reproducibility of the system by measuring the rotational and linear positions with respect to the programmed values. Our H-RMC system may provide a pivotal tool for spatial radiation imaging with high reliability and accuracy.

  13. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  14. Concern about aspects of body image and adjustment to early stage breast cancer.

    Science.gov (United States)

    Carver, C S; Pozo-Kaderman, C; Price, A A; Noriega, V; Harris, S D; Derhagopian, R P; Robinson, D S; Moffat, F L

    1998-01-01

    Several authors have suggested that patients adjust more poorly to breast cancer if they are heavily invested in body image as a source of their sense of self-worth. This prospective study examined this possibility, looking at two aspects of concern about body image as predictors of several indices of adjustment over the first postoperative year. At diagnosis (and again a year later) 66 women with early stage breast cancer reported how much they valued a) a sense of body integrity (or intactness) and b) a good physical appearance. The day before surgery, a week afterward, and at 3-month, 6-month, and 12-month follow ups, they reported on their mood. At presurgery and at follow ups they also rated their attractiveness and sexual desirability and reported on frequency of sexual interaction. At follow-ups they also indicated how much their illness and treatment were interfering with social and recreational activities. Initial investment in appearance was related to distress across the postsurgical year. In contrast, investment in appearance made women more resilient against deterioration in their perceptions of attractiveness. Concern about body integrity did not strongly predict emotional distress, but it related to adverse impact on social and recreational activities in the follow-up period, to deterioration in feelings of sexual desirability, and to feelings of alienation from the self (feeling "not like yourself anymore"). Body image is often thought of in terms of physical appearance, but there is also a body image pertaining to integrity, wholeness, and normal functioning. People who are greatly concerned about either aspect of their body image are vulnerable to poorer psychosocial adjustment when confronting treatment for breast cancer. The poorer adjustment takes a different form, however, depending on the nature of the patient's body-image concern.

  15. Design and simulation of a totally digital image system for medical image applications

    International Nuclear Information System (INIS)

    Archwamety, C.

    1987-01-01

    The Totally Digital Imaging System (TDIS) is based on system requirements information from the Radiology Department, University of Arizona Health Science Center. This dissertation presents the design of this complex system, the TDIS specification, the system performance requirements, and the evaluation of the system using the computer-simulation programs. Discrete-event simulation models were developed for the TDIS subsystems, including an image network, imaging equipment, storage migration algorithm, data base archive system, and a control and management network. The simulation system uses empirical data generation and retrieval rates measured at the University Medical Center hospital. The entire TDIS system was simulated in Simscript II.5 using a VAX 8600 computer system. Simulation results show the fiber-optical-image network to be suitable; however, the optical-disk-storage system represents a performance bottleneck

  16. Vibration isolation and dual-stage actuation pointing system for space precision payloads

    Science.gov (United States)

    Kong, Yongfang; Huang, Hai

    2018-02-01

    Pointing and stability requirements for future space missions are becoming more and more stringent. This work follows the pointing control method which consists of a traditional spacecraft attitude control system and a payload active pointing loop, further proposing a vibration isolation and dual-stage actuation pointing system for space precision payloads based on a soft Stewart platform. Central to the concept is using the dual-stage actuator instead of the traditional voice coil motor single-stage actuator to improve the payload active pointing capability. Based on a specified payload, the corresponding platform was designed to be installed between the spacecraft bus and the payload. The performance of the proposed system is demonstrated by preliminary closed-loop control investigations in simulations. With the ordinary spacecraft bus, the line-of-sight pointing accuracy can be controlled to below a few milliarcseconds in tip and tilt. Meanwhile, utilizing the voice coil motor with the softening spring in parallel, which is a portion of the dual-stage actuator, the system effectively achieves low-frequency motion transmission and high-frequency vibration isolation along the other four degree-of-freedom directions.

  17. Developing stereo image based robot control system

    Energy Technology Data Exchange (ETDEWEB)

    Suprijadi,; Pambudi, I. R.; Woran, M.; Naa, C. F; Srigutomo, W. [Department of Physics, FMIPA, InstitutTeknologi Bandung Jl. Ganesha No. 10. Bandung 40132, Indonesia supri@fi.itb.ac.id (Indonesia)

    2015-04-16

    Application of image processing is developed in various field and purposes. In the last decade, image based system increase rapidly with the increasing of hardware and microprocessor performance. Many fields of science and technology were used this methods especially in medicine and instrumentation. New technique on stereovision to give a 3-dimension image or movie is very interesting, but not many applications in control system. Stereo image has pixel disparity information that is not existed in single image. In this research, we proposed a new method in wheel robot control system using stereovision. The result shows robot automatically moves based on stereovision captures.

  18. MRI in local staging of rectal cancer: an update

    Science.gov (United States)

    Tapan, Ümit; Özbayrak, Mustafa; Tatlı, Servet

    2014-01-01

    Preoperative imaging for staging of rectal cancer has become an important aspect of current approach to rectal cancer management, because it helps to select suitable patients for neoadjuvant chemoradiotherapy and determine the appropriate surgical technique. Imaging modalities such as endoscopic ultrasonography, computed tomography, and magnetic resonance imaging (MRI) play an important role in assessing the depth of tumor penetration, lymph node involvement, mesorectal fascia and anal sphincter invasion, and presence of distant metastatic diseases. Currently, there is no consensus on a preferred imaging technique for preoperative staging of rectal cancer. However, high-resolution phased-array MRI is recommended as a standard imaging modality for preoperative local staging of rectal cancer, with excellent soft tissue contrast, multiplanar capability, and absence of ionizing radiation. This review will mainly focus on the role of MRI in preoperative local staging of rectal cancer and discuss recent advancements in MRI technique such as diffusion-weighted imaging and dynamic contrast-enhanced MRI. PMID:25010367

  19. Formation of the image on the receiver of thermal radiation

    Science.gov (United States)

    Akimenko, Tatiana A.

    2018-04-01

    The formation of the thermal picture of the observed scene with the verification of the quality of the thermal images obtained is one of the important stages of the technological process that determine the quality of the thermal imaging observation system. In this article propose to consider a model for the formation of a thermal picture of a scene, which must take into account: the features of the object of observation as the source of the signal; signal transmission through the physical elements of the thermal imaging system that produce signal processing at the optical, photoelectronic and electronic stages, which determines the final parameters of the signal and its compliance with the requirements for thermal information and measurement systems.

  20. Information and Analysis System Stages of Family Welfare in District Balong

    Directory of Open Access Journals (Sweden)

    Eka Arynda Ayu

    2017-05-01

    Full Text Available Badan Kependudukan dan Keluarga Berencana Nasional (BKKBN is a family that formed due to legal marriage, is able to meet the needs of the spiritual and the material that is decent, devoted to God Almighty, have a relationship that is harmonious and balanced between members and between families with the community and the environment. Every year the government to collect data on the status of a prosperous family stage where the purpose of the data collection is in the framework of development and poverty alleviation programs. Data collection process in the District Balong is still done manually so that the risk of error in determining the status of a family stage could happen. Information and analysis system of status stages of family welfare is designed to make web-based officers in the input data and determine the status of a prosperous family stages based on selected indicators of the sheet R/1/KS. Sample of data from Bulukidul village and sub-district village of Balong Ngraket 2014. Results of the system in the form of data reports the results of process steps and the results can be viewed in graphical form. Comparison chart to show the status of the highest percentage of poor welfare families stages. Instead lowest percentage shows the stages of a prosperous family able or rich. 

  1. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  2. An image analysis system for near-infrared (NIR) fluorescence lymph imaging

    Science.gov (United States)

    Zhang, Jingdan; Zhou, Shaohua Kevin; Xiang, Xiaoyan; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2011-03-01

    Quantitative analysis of lymphatic function is crucial for understanding the lymphatic system and diagnosing the associated diseases. Recently, a near-infrared (NIR) fluorescence imaging system is developed for real-time imaging lymphatic propulsion by intradermal injection of microdose of a NIR fluorophore distal to the lymphatics of interest. However, the previous analysis software3, 4 is underdeveloped, requiring extensive time and effort to analyze a NIR image sequence. In this paper, we develop a number of image processing techniques to automate the data analysis workflow, including an object tracking algorithm to stabilize the subject and remove the motion artifacts, an image representation named flow map to characterize lymphatic flow more reliably, and an automatic algorithm to compute lymph velocity and frequency of propulsion. By integrating all these techniques to a system, the analysis workflow significantly reduces the amount of required user interaction and improves the reliability of the measurement.

  3. Image acquisition system for traffic monitoring applications

    Science.gov (United States)

    Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben

    1995-03-01

    An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic

  4. Image guided multibeam radiotherapy

    International Nuclear Information System (INIS)

    Freijo, J.L.

    2008-01-01

    This paper provides an outlook of the status of the first development stages for an updated design of radiotherapy conformal system based on tumor 3D images obtained as an output the last generation imaging machines as PET, CT and MR which offer a very valuable output in cancer diagnosis. Prospective evaluation of current software codes and acquisition of useful experience in surgical planning involves a multidisciplinary process as an initial and unavoidable stage to develop an expert software and user skills which assures the delivery of the radiation dose is done correctly in geometry and value in each voxel as a radiation protection basic condition. The validation of the images obtained has been done by the production of anatomical models of interest regions by rapid proto typing of the 3D segmented images and its evaluation by contrasting with the real regions during surgical procedures. (author)

  5. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    Science.gov (United States)

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  6. Application of multimedia image technology in engineering report demonstration system

    Science.gov (United States)

    Lili, Jiang

    2018-03-01

    With the rapid development of global economic integration, people’s strong desire for a wide range of global exchanges and interactions has been promoted, and there are more unprecedented convenient means for people to know the world and even to transform the world. At this stage, we realize that the traditional mode of work has become difficult to adapt to the changing trends of the world and informatization, multimedia, science and technology have become the mainstream of the times. Therefore, this paper will mainly analyze the present situation of the project report demonstration system and the key points of the work and put forward with pertinence specific application strategy of the integration with multimedia image technology.

  7. Influence of capacity- and time-constrained intermediate storage in two-stage food production systems

    DEFF Research Database (Denmark)

    Akkerman, Renzo; van Donk, Dirk Pieter; Gaalman, Gerard

    2007-01-01

    In food processing, two-stage production systems with a batch processor in the first stage and packaging lines in the second stage are common and mostly separated by capacity- and time-constrained intermediate storage. This combination of constraints is common in practice, but the literature hardly...... of systems like this. Contrary to the common sense in operations management, the LPT rule is able to maximize the total production volume per day. Furthermore, we show that adding one tank has considerable effects. Finally, we conclude that the optimal setup frequency for batches in the first stage...... pays any attention to this. In this paper, we show how various capacity and time constraints influence the performance of a specific two-stage system. We study the effects of several basic scheduling and sequencing rules in the presence of these constraints in order to learn the characteristics...

  8. Value of five-stage prognostic system in predicting short-term outcome of patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    TIAN Yan

    2015-03-01

    Full Text Available ObjectiveTo evaluate the clinical value of five-stage prognostic system in predicting the short-term outcome of patients with liver cirrhosis, and to compare it with the Child-Turcotte-Pugh (CTP and Model of End-Stage Liver Disease (MELD scores. MethodsTwo hundred and one hospitalized patients with liver cirrhosis in the Department of Gastroenterology in the First Affiliated Hospital of Anhui Medical University from January 2011 to January 2014 were enrolled in the study and followed up for at least six months. Patients were classified accorded to the five-stage prognostic system, and the mortality rate in each stage was measured. The receiver operating characteristic (ROC curve and the area under the ROC curve (AUC were used to assess the accuracy of the five-stage prognostic system in predicting the short-term death risk of cirrhotic patients, which was then compared with the CTP and MELD scores. Categorical data were analyzed by chi-square test. Comparison of AUC was made by normal distribution Z test. Spearman′s correlation analysis was used to investigate the correlation of the five-stage prognostic system with the CTP and MELD scores. ResultsThe study used the admission time as the starting point and the death of patients or study termination time as the endpoint. Among the 201 patients, 50 (24.9% died within six months. Based on the five-stage prognostic system, the mortality rates for stages 1 to 5 were 0(0/11, 0(0/18, 4.2%(2/48, 16.3% (7/43, and 50.6%(41/81, respectively. In patients with decompensated cirrhosis (stages 3, 4, and 5, the mortality increased with stage, and the differences in mortality between patients in stages 3 and 4, 3 and 5, and 4 and 5 were all significant (χ2=3.89, 35.33, and 13.96, respectively; P=0.049, 0.000, and 0.049, respectively. The AUC for the five-stage prognostic system, five-stage prognostic system combined with CTP and MELD score, and CTP score were 0820, 0.915, 0.888, and 0

  9. Consultation system for image diagnosis: Report formation support system

    International Nuclear Information System (INIS)

    Ikeda, M.; Sakuma, S.; Ishigaki, T.; Suzuki, K.; Oikawa, K.

    1987-01-01

    The authors developed a consultation system for image diagnosis, involving artificial intelligence ideas. In this system, the authors proposed a new report formation support system and implemented it in lymphangiography. This support system starts with the input of image interpretation. The input process is made mainly by selecting items. This system encodes the input findings into the semantic network, which is represented as a directed graph, and it reserves them into the knowledge database in the above structure. Finally, the output (report) is made in the near natural language, which corresponds to the input findings

  10. Digital radiology and digitally formatted image management systems

    International Nuclear Information System (INIS)

    Cox, G.G.; Dwyer, S.J. III; Templeton, A.W.

    1987-01-01

    The number of diagnostic examinations performed with digitally formatted imaging equipment is increasing. Digital general-purpose and fluoroscopic radiology systems are being clinically evaluated. Digitizing conventional x-ray films, such as mammograms, frequently improves the diagnostic quality of the images. The digitizing process with laser has also afforded the opportunity to document required spatial resolution for digital imaging and network systems. The use of digitally formatted image instrumentation imposes new requirements on the acquisition, display and manipulation, transmission, hard copy image recording, and archiving of diagnostic data. Networking of digitally formatted image data offers many advantages for managing digital information. This paper identifies and describes digital radiographic systems. Parameters required for designing and implementing a digital image management system are outlined. Spatial and contrast resolution requirements are identified. The key parameters include the amount of image data generated each working day, the retrieval rate of the generated data, the display hardware and software needed for interactive diagnosis display stations, the requirements for analog hard copy generation, and on-line and long-term archiving requirements. These image management systems are often called PACS (Picture Archiving and Communication Systems)

  11. TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, M. [Memorial Sloan-Kettering Cancer Center (United States)

    2015-06-15

    This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI

  12. Optimization of a Two Stage Pulse Tube Refrigerator for the Integrated Current Lead System

    Science.gov (United States)

    Maekawa, R.; Matsubara, Y.; Okada, A.; Takami, S.; Konno, M.; Tomioka, A.; Imayoshi, T.; Hayashi, H.; Mito, T.

    2008-03-01

    Implementation of a conventional current lead with a pulse tube refrigerator has been validated to be working as an Integrated Current Lead (ICL) system for the Superconducting Magnetic Energy Storage (SMES). Realization of the system is primarily accounted for the flexibility of a pulse tube refrigerator, which does not posses any mechanical piston and/or displacer. As for an ultimate version of the ICL system, a High Temperature Superconducting (HTS) lead links a superconducting coil with a conventional copper lead. To ensure the minimization of heat loads to the superconducting coil, a pulse tube refrigerator has been upgraded to have a second cooling stage. This arrangement reduces not only the heat loads to the superconducting coil but also the operating cost for a SMES system. A prototype two-stage pulse tube refrigerator, series connected arrangement, was designed and fabricated to satisfy the requirements for the ICL system. Operation of the first stage refrigerator is a four-valve mode, while the second stage utilizes a double inlet configuration to ensure its confined geometry. The paper discusses the optimization of second stage cooling to validate the conceptual design

  13. Low cost light-sheet microscopy for whole brain imaging

    Science.gov (United States)

    Kumar, Manish; Nasenbeny, Jordan; Kozorovitskiy, Yevgenia

    2018-02-01

    Light-sheet microscopy has evolved as an indispensable tool in imaging biological samples. It can image 3D samples at fast speed, with high-resolution optical sectioning, and with reduced photobleaching effects. These properties make light-sheet microscopy ideal for imaging fluorophores in a variety of biological samples and organisms, e.g. zebrafish, drosophila, cleared mouse brains, etc. While most commercial turnkey light-sheet systems are expensive, the existing lower cost implementations, e.g. OpenSPIM, are focused on achieving high-resolution imaging of small samples or organisms like zebrafish. In this work, we substantially reduce the cost of light-sheet microscope system while targeting to image much larger samples, i.e. cleared mouse brains, at single-cell resolution. The expensive components of a lightsheet system - excitation laser, water-immersion objectives, and translation stage - are replaced with an incoherent laser diode, dry objectives, and a custom-built Arduino-controlled translation stage. A low-cost CUBIC protocol is used to clear fixed mouse brain samples. The open-source platforms of μManager and Fiji support image acquisition, processing, and visualization. Our system can easily be extended to multi-color light-sheet microscopy.

  14. Diffusion-weighted MR imaging in comparison to integrated [18F]-FDG PET/CT for N-staging in patients with lung cancer

    International Nuclear Information System (INIS)

    Pauls, Sandra; Schmidt, Stefan A.; Juchems, Markus S.; Klass, Oliver; Luster, Markus; Reske, Sven Norbert; Brambs, Hans-Juergen; Feuerlein, Sebastian

    2012-01-01

    Purpose The purpose of this study was to prospectively determine the diagnostic accuracy of diffusion-weighted imaging (DWI) using MRI in the staging of thoracic lymph nodes in patients with lung cancer, and to compare the performance to that of PET/CT. Patients and Method 20 consecutive patients (pts) with histologically proven lung cancer were included in this study. In all pts FDG-PET/CT was routinely performed to stage lung carcinoma. Additionally, MRI (1.5 T) was performed including native T1w, T1w post contrast medium, T2w, and DWI sequences. Regarding the N stage based on the results of the PET/CT there were 5 patients with N0, 3 patients with N1, 5 patients with N2 and 7 patients with N3. Image analysis was performed by two radiologists (R1 and R2), respectively. The reviewers had to chose between 1 (at least one lymph node within a station is malignant) or 0 (no lymph nodes suspicious for malignancy). First the T1 post contrast sequence was analyzed. In a second step the DWI sequence (b = 800) was analyzed. Both steps were performed in a blinded fashion. Results MR imaging with or without DWI only agreed with the results of the PET/CT regarding the N stage in 80% of the patients—15% were understaged and 5% overstaged. There was excellent interobserver agreement; the N-staging result only differed in 1 patient for DWI, resulting in correlation coefficients of 0.98 for DWI and 1.0 for MRI. Compared to PET-CT MRI overstaged one and understaged 4 patients, while DWI overstaged one and understaged 3 patients. This resulted in correlation coefficients of 0.814 (R1 and R2) for MRI and 0.815 (R1) and 0.804 (R2) for DWI. Regarding the ADC values there were no significant differences between ipsilateral hilar (1.03 mm 2 /s ± 0.13), subcarinal (0.96 mm 2 /s ± 0.24), ipsilateral mediastinal (1.0 mm 2 /s ± 0.18), contralateral mediastinal (0.93 mm 2 /s ± 0.23) and supraclavicular (0.9 mm 2 /s ± 0.23) lymph nodes. Conclusion Diffusion-weighted imaging does not

  15. Multi-stage fuzzy PID power system automatic generation controller in deregulated environments

    International Nuclear Information System (INIS)

    Shayeghi, H.; Shayanfar, H.A.; Jalili, A.

    2006-01-01

    In this paper, a multi-stage fuzzy proportional integral derivative (PID) type controller is proposed to solve the automatic generation control (AGC) problem in a deregulated power system that operates under deregulation based on the bilateral policy scheme. In each control area, the effects of the possible contracts are treated as a set of new input signals in a modified traditional dynamical model. The multi-stage controller uses the fuzzy switch to blend a proportional derivative (PD) fuzzy logic controller with an integral fuzzy logic input. The proposed controller operates on fuzzy values passing the consequence of a prior stage on to the next stage as fact. The salient advantage of this strategy is its high insensitivity to large load changes and disturbances in the presence of plant parameter variations and system nonlinearities. This newly developed strategy leads to a flexible controller with simple structure that is easy to implement, and therefore, it can be useful for the real world power systems. The proposed method is tested on a three area power system with different contracted scenarios under various operating conditions. The results of the proposed controller are compared with those of the classical fuzzy PID type controller and classical PID controller through some performance indices to illustrate its robust performance

  16. Comparison of applied dose and image quality in staging CT of neuroendocrine tumor patients using standard filtered back projection and adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Böning, G; Schäfer, M; Grupp, U; Kaul, D; Kahn, J; Pavel, M; Maurer, M; Denecke, T; Hamm, B; Streitparth, F

    2015-08-01

    To investigate whether dose reduction via adaptive statistical iterative reconstruction (ASIR) affects image quality and diagnostic accuracy in neuroendocrine tumor (NET) staging. A total of 28 NET patients were enrolled in the study. Inclusion criteria were histologically proven NET and visible tumor in abdominal computed tomography (CT). In an intraindividual study design, the patients underwent a baseline CT (filtered back projection, FBP) and follow-up CT (ASIR 40%) using matched scan parameters. Image quality was assessed subjectively using a 5-grade scoring system and objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs). Applied volume computed tomography dose index (CTDIvol) of each scan was taken from the dose report. ASIR 40% significantly reduced CTDIvol (10.17±3.06mGy [FBP], 6.34±2.25mGy [ASIR] (pASIR]) (pASIR]) (pASIR]), visibility of suspicious lesion (4.8±0.5 [FBP], 4.8±0.5 [ASIR]) and artifacts (5.0±0 [FBP], 5.0±0 [ASIR]). ASIR 40% significantly decreased scores for noise (4.3±0.6 [FBP], 4.0±0.8 [ASIR]) (pASIR]) (pASIR]) (pASIR can be used to reduce radiation dose without sacrificing image quality and diagnostic confidence in staging CT of NET patients. This may be beneficial for patients with frequent follow-up and significant cumulative radiation exposure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Detection of nuclei in 4D Nomarski DIC microscope images of early Caenorhabditis elegans embryos using local image entropy and object tracking

    Directory of Open Access Journals (Sweden)

    Hamahashi Shugo

    2005-05-01

    Full Text Available Abstract Background The ability to detect nuclei in embryos is essential for studying the development of multicellular organisms. A system of automated nuclear detection has already been tested on a set of four-dimensional (4D Nomarski differential interference contrast (DIC microscope images of Caenorhabditis elegans embryos. However, the system needed laborious hand-tuning of its parameters every time a new image set was used. It could not detect nuclei in the process of cell division, and could detect nuclei only from the two- to eight-cell stages. Results We developed a system that automates the detection of nuclei in a set of 4D DIC microscope images of C. elegans embryos. Local image entropy is used to produce regions of the images that have the image texture of the nucleus. From these regions, those that actually detect nuclei are manually selected at the first and last time points of the image set, and an object-tracking algorithm then selects regions that detect nuclei in between the first and last time points. The use of local image entropy makes the system applicable to multiple image sets without the need to change its parameter values. The use of an object-tracking algorithm enables the system to detect nuclei in the process of cell division. The system detected nuclei with high sensitivity and specificity from the one- to 24-cell stages. Conclusion A combination of local image entropy and an object-tracking algorithm enabled highly objective and productive detection of nuclei in a set of 4D DIC microscope images of C. elegans embryos. The system will facilitate genomic and computational analyses of C. elegans embryos.

  18. Imaging defined risk factors in neuroblastoma -guidelines for optimising imaging interpretations

    International Nuclear Information System (INIS)

    Valchev, G.; Balev, B.

    2017-01-01

    Neuroblastoma is the most frequent extracranial tumor in children, arising from the primitive sympathetic cells and the adrenal medulla. Two separate mutually complementing staging systems exist - INSS and INRGSS - one is based on post-operative findings, the other - on pre-treatment imaging. INRGSS consists of a list of 20 separate imaging defined risk factors (IDRF), the presence of which could alter the treatment plan. Radiologists need to be aware of certain intricacies in interpreting the individual IDRFs in order to optimise clinical decision-making. Key words: neuroblastoma. imaging defined risk factors (IDRF). interpretation guidelines [bg

  19. An integral design strategy combining optical system and image processing to obtain high resolution images

    Science.gov (United States)

    Wang, Jiaoyang; Wang, Lin; Yang, Ying; Gong, Rui; Shao, Xiaopeng; Liang, Chao; Xu, Jun

    2016-05-01

    In this paper, an integral design that combines optical system with image processing is introduced to obtain high resolution images, and the performance is evaluated and demonstrated. Traditional imaging methods often separate the two technical procedures of optical system design and imaging processing, resulting in the failures in efficient cooperation between the optical and digital elements. Therefore, an innovative approach is presented to combine the merit function during optical design together with the constraint conditions of image processing algorithms. Specifically, an optical imaging system with low resolution is designed to collect the image signals which are indispensable for imaging processing, while the ultimate goal is to obtain high resolution images from the final system. In order to optimize the global performance, the optimization function of ZEMAX software is utilized and the number of optimization cycles is controlled. Then Wiener filter algorithm is adopted to process the image simulation and mean squared error (MSE) is taken as evaluation criterion. The results show that, although the optical figures of merit for the optical imaging systems is not the best, it can provide image signals that are more suitable for image processing. In conclusion. The integral design of optical system and image processing can search out the overall optimal solution which is missed by the traditional design methods. Especially, when designing some complex optical system, this integral design strategy has obvious advantages to simplify structure and reduce cost, as well as to gain high resolution images simultaneously, which has a promising perspective of industrial application.

  20. Cross-sectional imaging to evaluate the extent of regional nodal disease in breast cancer patients undergoing neoadjuvant systemic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Tara L., E-mail: anderson.tara@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Glazebrook, Katrina N., E-mail: glazebrook.katrina@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Murphy, Brittany L., E-mail: murphy.brittany@mayo.edu [Mayo Clinic, Department of Surgery, 200 First Street SW, Rochester, MN, 55905 (United States); Viers, Lyndsay D., E-mail: viers.lyndsay@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Hieken, Tina J, E-mail: hieken.tina@mayo.edu [Mayo Clinic, Department of Surgery, 200 First Street SW, Rochester, MN, 55905 (United States)

    2017-04-15

    Purpose: Cross-sectional imaging often is performed in breast cancer patients undergoing neoadjuvant systemic therapy (NST) and may identify level III axillary and extra-axillary nodal disease. Our aim was to investigate associations of radiologic nodal staging with pathological N (pN) stage at operation and to explore how this might aid surgical and radiotherapy treatment planning. Materials and methods: With IRB approval, we reviewed pre-treatment breast MRI, PET/CT, and CT imaging and clinicopathologic data on 348 breast cancer patients with imaging available for review undergoing NST followed by operation at our institution 1/2008-9/2013. We defined abnormal lymph node findings on MRI, CT, and PET/CT to include cortical thickening, FDG-avidity and loss of fatty hilum. Patients were assigned a radiologic nodal (rN) stage based on imaging findings. Statistical analysis was performed using JMP 10.1 software Results: Pre-NST imaging included axillary ultrasound in 338 patients (97%), breast MRI in 305 (88%) and PET/CT or CT in 215 (62%). 213 patients (61%) were biopsy-proven axillary lymph node-positive (LN+) pre-treatment. cT stage was T1 in 9%, T2 in 49%, T3 in 29%, T4 in 12%; median tumor size was 4 cm. Pre-treatment rN stage across all the patients was rN0 in 86 (25%), rN1 in 173 (50%), and rN3 in 89 (26%). rN3 disease included level III axillary, supraclavicular and suspicious internal mammary lymph nodes in 47 (53%), 32 (37%) and 45 (52%), respectively. Of patients LN+ at diagnosis, 78 (37%) were rN3. After NST, 162 patients (47%) were node-positive at operation with a median (mean) of 3 (5.9 ± 0.4) positive lymph nodes including 128 of 213 (60%) LN+ at diagnosis. Pre-NST rN stage correlated with the likelihood and extent of axillary disease at operation, p = 0.002. Fifty four of 89 rN3 patients (61%) were node-positive at operation with a median (mean) of 5 (8 ± 1) positive nodes. rN3 patients had larger nodal metastases (median 9 vs 6 mm) and more

  1. Cross-sectional imaging to evaluate the extent of regional nodal disease in breast cancer patients undergoing neoadjuvant systemic therapy

    International Nuclear Information System (INIS)

    Anderson, Tara L.; Glazebrook, Katrina N.; Murphy, Brittany L.; Viers, Lyndsay D.; Hieken, Tina J

    2017-01-01

    Purpose: Cross-sectional imaging often is performed in breast cancer patients undergoing neoadjuvant systemic therapy (NST) and may identify level III axillary and extra-axillary nodal disease. Our aim was to investigate associations of radiologic nodal staging with pathological N (pN) stage at operation and to explore how this might aid surgical and radiotherapy treatment planning. Materials and methods: With IRB approval, we reviewed pre-treatment breast MRI, PET/CT, and CT imaging and clinicopathologic data on 348 breast cancer patients with imaging available for review undergoing NST followed by operation at our institution 1/2008-9/2013. We defined abnormal lymph node findings on MRI, CT, and PET/CT to include cortical thickening, FDG-avidity and loss of fatty hilum. Patients were assigned a radiologic nodal (rN) stage based on imaging findings. Statistical analysis was performed using JMP 10.1 software Results: Pre-NST imaging included axillary ultrasound in 338 patients (97%), breast MRI in 305 (88%) and PET/CT or CT in 215 (62%). 213 patients (61%) were biopsy-proven axillary lymph node-positive (LN+) pre-treatment. cT stage was T1 in 9%, T2 in 49%, T3 in 29%, T4 in 12%; median tumor size was 4 cm. Pre-treatment rN stage across all the patients was rN0 in 86 (25%), rN1 in 173 (50%), and rN3 in 89 (26%). rN3 disease included level III axillary, supraclavicular and suspicious internal mammary lymph nodes in 47 (53%), 32 (37%) and 45 (52%), respectively. Of patients LN+ at diagnosis, 78 (37%) were rN3. After NST, 162 patients (47%) were node-positive at operation with a median (mean) of 3 (5.9 ± 0.4) positive lymph nodes including 128 of 213 (60%) LN+ at diagnosis. Pre-NST rN stage correlated with the likelihood and extent of axillary disease at operation, p = 0.002. Fifty four of 89 rN3 patients (61%) were node-positive at operation with a median (mean) of 5 (8 ± 1) positive nodes. rN3 patients had larger nodal metastases (median 9 vs 6 mm) and more

  2. Nuclear imaging system

    International Nuclear Information System (INIS)

    Barrett, H.H.; Horrigan, F.A.

    1975-01-01

    This invention relates to a nuclear imaging system for mapping the source of high energy nuclear particles from a living organ which has selectively absorbed a radioactive compound by spatially coding the energy from the source in a Fresnel pattern on a detector and decoding the detector output to prouce an image of the source. The coding is produced by a Fresnel zone plate interposed between the nuclear energy source and the detector whose position is adjustable with respect to the detector to focus the slices of the nuclear source on the detector. By adjusting the zone plate to a plurality of positions, data from a plurality of cross-sectional slices are produced from which a three-dimensional image of the nuclear source may be obtained. (Patent Office Record)

  3. Imaging quality evaluation method of pixel coupled electro-optical imaging system

    Science.gov (United States)

    He, Xu; Yuan, Li; Jin, Chunqi; Zhang, Xiaohui

    2017-09-01

    With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become ;flexible; with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated.

  4. Development of automatic radiographic inspection system using digital image processing and artificial intelligence

    International Nuclear Information System (INIS)

    Itoga, Kouyu; Sugimoto, Koji; Michiba, Koji; Kato, Yuhei; Sugita, Yuji; Onda, Katsuhiro.

    1991-01-01

    The application of computers to welding inspection is expanding rapidly. The classification of the application is the collection, analysis and processing of data, the graphic display of results, the distinction of the kinds of defects and the evaluation of the harmufulness of defects and the judgement of acceptance or rejection. The application of computer techniques to the automation of data collection was realized at the relatively early stage. Data processing and the graphic display of results are the techniques in progress now, and the application of artificial intelligence to the distinction of the kinds of defects and the evaluation of harmfulness is expected to expand rapidly. In order to computerize radiographic inspection, the abilities of image processing technology and knowledge engineering must be given to computers. The object of this system is the butt joints by arc welding of the steel materials of up to 30 mm thickness. The digitizing transformation of radiographs, the distinction and evaluation of transmissivity and gradation by image processing, and only as for those, of which the picture quality satisfies the standard, the extraction of defect images, their display, the distinction of the kinds and the final judgement are carried out. The techniques of image processing, the knowledge for distinguishing the kinds of defects and the concept of the practical system are reported. (K.I.)

  5. Computer simulation of a staging system for a theta-pinch reactor (RTPR)

    International Nuclear Information System (INIS)

    Crnkovich, P.G.

    1976-02-01

    To reduce excessive energy requirements for the implosion heating system of a theta-pinch reactor, two staging methods, the brute force and bucking field options, were proposed. A Marshall coil and a segmented coil were also considered. Calculations involved in coding these coil designs and staging options into a PL/I subprogram are described. A marked savings in the energy required for the IH system is realized with the bucking option and others

  6. A two-stage multi-view learning framework based computer-aided diagnosis of liver tumors with contrast enhanced ultrasound images.

    Science.gov (United States)

    Guo, Le-Hang; Wang, Dan; Qian, Yi-Yi; Zheng, Xiao; Zhao, Chong-Ke; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen; Zhang, Qi; Shi, Jun; Xu, Hui-Xiong

    2018-04-04

    With the fast development of artificial intelligence techniques, we proposed a novel two-stage multi-view learning framework for the contrast-enhanced ultrasound (CEUS) based computer-aided diagnosis for liver tumors, which adopted only three typical CEUS images selected from the arterial phase, portal venous phase and late phase. In the first stage, the deep canonical correlation analysis (DCCA) was performed on three image pairs between the arterial and portal venous phases, arterial and delayed phases, and portal venous and delayed phases respectively, which then generated total six-view features. While in the second stage, these multi-view features were then fed to a multiple kernel learning (MKL) based classifier to further promote the diagnosis result. Two MKL classification algorithms were evaluated in this MKL-based classification framework. We evaluated proposed DCCA-MKL framework on 93 lesions (47 malignant cancers vs. 46 benign tumors). The proposed DCCA-MKL framework achieved the mean classification accuracy, sensitivity, specificity, Youden index, false positive rate, and false negative rate of 90.41 ± 5.80%, 93.56 ± 5.90%, 86.89 ± 9.38%, 79.44 ± 11.83%, 13.11 ± 9.38% and 6.44 ± 5.90%, respectively, by soft margin MKL classifier. The experimental results indicate that the proposed DCCA-MKL framework achieves best performance for discriminating benign liver tumors from malignant liver cancers. Moreover, it is also proved that the three-phase CEUS image based CAD is feasible for liver tumors with the proposed DCCA-MKL framework.

  7. Development and validation of a surgical-pathologic staging and scoring system for cervical cancer.

    Science.gov (United States)

    Li, Shuang; Li, Xiong; Zhang, Yuan; Zhou, Hang; Tang, Fangxu; Jia, Yao; Hu, Ting; Sun, Haiying; Yang, Ru; Chen, Yile; Cheng, Xiaodong; Lv, Weiguo; Wu, Li; Zhou, Jin; Wang, Shaoshuai; Huang, Kecheng; Wang, Lin; Yao, Yuan; Yang, Qifeng; Yang, Xingsheng; Zhang, Qinghua; Han, Xiaobing; Lin, Zhongqiu; Xing, Hui; Qu, Pengpeng; Cai, Hongbing; Song, Xiaojie; Tian, Xiaoyu; Shen, Jian; Xi, Ling; Li, Kezhen; Deng, Dongrui; Wang, Hui; Wang, Changyu; Wu, Mingfu; Zhu, Tao; Chen, Gang; Gao, Qinglei; Wang, Shixuan; Hu, Junbo; Kong, Beihua; Xie, Xing; Ma, Ding

    2016-04-12

    Most cervical cancer patients worldwide receive surgical treatments, and yet the current International Federation of Gynecology and Obstetrics (FIGO) staging system do not consider surgical-pathologic data. We propose a more comprehensive and prognostically valuable surgical-pathologic staging and scoring system (SPSs). Records from 4,220 eligible cervical cancer cases (Cohort 1) were screened for surgical-pathologic risk factors. We constructed a surgical-pathologic staging and SPSs, which was subsequently validated in a prospective study of 1,104 cervical cancer patients (Cohort 2). In Cohort 1, seven independent risk factors were associated with patient outcome: lymph node metastasis (LNM), parametrial involvement, histological type, grade, tumor size, stromal invasion, and lymph-vascular space invasion (LVSI). The FIGO staging system was revised and expanded into a surgical-pathologic staging system by including additional criteria of LNM, stromal invasion, and LVSI. LNM was subdivided into three categories based on number and location of metastases. Inclusion of all seven prognostic risk factors improves practical applicability. Patients were stratified into three SPSs risk categories: zero-, low-, and high-score with scores of 0, 1 to 3, and ≥4 (P=1.08E-45; P=6.15E-55). In Cohort 2, 5-year overall survival (OS) and disease-free survival (DFS) outcomes decreased with increased SPSs scores (P=9.04E-15; P=3.23E-16), validating the approach. Surgical-pathologic staging and SPSs show greater homogeneity and discriminatory utility than FIGO staging. Surgical-pathologic staging and SPSs improve characterization of tumor severity and disease invasion, which may more accurately predict outcome and guide postoperative therapy.

  8. Scanned Image Projection System Employing Intermediate Image Plane

    Science.gov (United States)

    DeJong, Christian Dean (Inventor); Hudman, Joshua M. (Inventor)

    2014-01-01

    In imaging system, a spatial light modulator is configured to produce images by scanning a plurality light beams. A first optical element is configured to cause the plurality of light beams to converge along an optical path defined between the first optical element and the spatial light modulator. A second optical element is disposed between the spatial light modulator and a waveguide. The first optical element and the spatial light modulator are arranged such that an image plane is created between the spatial light modulator and the second optical element. The second optical element is configured to collect the diverging light from the image plane and collimate it. The second optical element then delivers the collimated light to a pupil at an input of the waveguide.

  9. Evaluation of transmitted images by teleradiology system

    International Nuclear Information System (INIS)

    Hoshikawa, Yoshikazu

    1993-01-01

    Teleradiology system is a combination of digital data networks and computer systems, which is the electric transmission of radiographs and/or radiologic images from local to center radiological system. The author evaluated reproducibility of transmitted images using Photophone (Image Data Corporation) as teleradiology system. Proven cases of abdominal free air (38 plain films, 15 CT), pneumothorax (24 plain films, 20 CT) and small bowel obstruction (30 plain films, 8 CT) were transmitted. Findings could be identified on non-magnified plain films in 75.6%, 83.3% and 96.7% respectively and on magnified CT in 100%, 100% and 100%. Transmitted images of 57 cases of abdominal trauma were read for positive findings and diagnosis by three radiologists. Average positive ratio was 47.3% on plain films and 70.9% on CT. Diagnosis was correct in 66.7% on CT. Specificity and sensitivity were 81.9% and 61.6% respectively on plain film and 88.6% and 93.9% on CT. The accuracy of transmitted images appears to be unsatisfactory on this study. It is suggested that the system is useful for consultation of already identified findings on the original images. (author)

  10. Evaluation of transmitted images by teleradiology system

    Energy Technology Data Exchange (ETDEWEB)

    Hoshikawa, Yoshikazu (St. Marianna Univ., Kawasaki (Japan). School of Medicine)

    1993-12-01

    Teleradiology system is a combination of digital data networks and computer systems, which is the electric transmission of radiographs and/or radiologic images from local to center radiological system. The author evaluated reproducibility of transmitted images using Photophone (Image Data Corporation) as teleradiology system. Proven cases of abdominal free air (38 plain films, 15 CT), pneumothorax (24 plain films, 20 CT) and small bowel obstruction (30 plain films, 8 CT) were transmitted. Findings could be identified on non-magnified plain films in 75.6%, 83.3% and 96.7% respectively and on magnified CT in 100%, 100% and 100%. Transmitted images of 57 cases of abdominal trauma were read for positive findings and diagnosis by three radiologists. Average positive ratio was 47.3% on plain films and 70.9% on CT. Diagnosis was correct in 66.7% on CT. Specificity and sensitivity were 81.9% and 61.6% respectively on plain film and 88.6% and 93.9% on CT. The accuracy of transmitted images appears to be unsatisfactory on this study. It is suggested that the system is useful for consultation of already identified findings on the original images. (author).

  11. Fill Rates of Single-Stage and Multistage Supply Systems

    OpenAIRE

    Matthew J. Sobel

    2004-01-01

    A supply system's fill rate is the fraction of demand that is met from on-hand inventory. This paper presents formulas for the fill rate of periodic review supply systems that use base-stock-level policies. The first part of the paper contains fill-rate formulas for a single-stage system and general distributions of demand. When demand is normally distributed, an exact expression uses only the standard normal distribution and density functions, and a good approximation uses only the standard ...

  12. The National Ignition Facility Neutron Imaging System

    International Nuclear Information System (INIS)

    Wilke, Mark D.; Batha, Steven H.; Bradley, Paul A.; Day, Robert D.; Clark, David D.; Fatherley, Valerie E.; Finch, Joshua P.; Gallegos, Robert A.; Garcia, Felix P.; Grim, Gary P.; Jaramillo, Steven A.; Montoya, Andrew J.; Morgan, George L.; Oertel, John A.; Ortiz, Thomas A.; Payton, Jeremy R.; Pazuchanics, Peter; Schmidt, Derek W.; Valdez, Adelaida C.; Wilde, Carl H.

    2008-01-01

    The National Ignition Facility (NIF) is scheduled to begin deuterium-tritium (DT) shots possibly in the next several years. One of the important diagnostics in understanding capsule behavior and to guide changes in Hohlraum illumination, capsule design, and geometry will be neutron imaging of both the primary 14 MeV neutrons and the lower-energy downscattered neutrons in the 6-13 MeV range. The neutron imaging system (NIS) described here, which we are currently building for use on NIF, uses a precisely aligned set of apertures near the target to form the neutron images on a segmented scintillator. The images are recorded on a gated, intensified charge coupled device. Although the aperture set may be as close as 20 cm to the target, the imaging camera system will be located at a distance of 28 m from the target. At 28 m the camera system is outside the NIF building. Because of the distance and shielding, the imager will be able to obtain images with little background noise. The imager will be capable of imaging downscattered neutrons from failed capsules with yields Y n >10 14 neutrons. The shielding will also permit the NIS to function at neutron yields >10 18 , which is in contrast to most other diagnostics that may not work at high neutron yields. The following describes the current NIF NIS design and compares the predicted performance with the NIF specifications that must be satisfied to generate images that can be interpreted to understand results of a particular shot. The current design, including the aperture, scintillator, camera system, and reconstruction methods, is briefly described. System modeling of the existing Omega NIS and comparison with the Omega data that guided the NIF design based on our Omega results is described. We will show NIS model calculations of the expected NIF images based on component evaluations at Omega. We will also compare the calculated NIF input images with those unfolded from the NIS images generated from our NIS numerical

  13. An integrated on-line irradiation and in situ live cell imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen, E-mail: gen.yang@pku.edu.cn; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO{sub 2}, O{sub 2} concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  14. An integrated on-line irradiation and in situ live cell imaging system

    International Nuclear Information System (INIS)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-01-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO 2 , O 2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia

  15. An integrated on-line irradiation and in situ live cell imaging system

    Science.gov (United States)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO2, O2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  16. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  17. Development and testing of a de novo clinical staging system for podoconiosis (endemic non-filarial elephantiasis).

    Science.gov (United States)

    Tekola, Fasil; Ayele, Zewdu; Mariam, Dereje Haile; Fuller, Claire; Davey, Gail

    2008-10-01

    To develop and test a robust clinical staging system for podoconiosis, a geochemical disease in individuals exposed to red clay soil. We adapted the Dreyer system for staging filarial lymphoedema and tested it in four re-iterative field tests conducted in an area of high-podoconiosis prevalence in Southern Ethiopia. The system has five stages according to proximal spread of disease and presence of dermal nodules, ridges and bands. We measured the 1-week repeatability and the inter-observer agreement of the final staging system. The five-stage system is readily understood by community workers with little health training. Kappa for 1-week repeatability was 0.88 (95% CI 0.80-0.96), for agreement between health professionals was 0.71 (95% CI 0.60-0.82), while that between health professionals and community podoconiosis agents without formal health training averaged 0.64 (95% CI 0.52-0.78). This simple staging system with good inter-observer agreement and repeatability can assist in the management and further study of podoconiosis.

  18. Magnetic resonance for T-staging of nasopharyngeal carcinoma. The most informative pair of sequences

    International Nuclear Information System (INIS)

    Lau, Kam Y.; Kan, Wai K.; Sze, Wai M.

    2004-01-01

    The objective of this study was to evaluate the most informative pair of sequences in magnetic resonance (MR) for T-staging of nasopharyngeal carcinoma (NPC). The MR images of 134 patients with newly diagnosed NRC, from 1996 to 2002, were retrospectively reviewed. All the patients were scanned using 1.5 Tesla MR systems. The images of the nasopharynx were reviewed by two qualified radiologists to determine the positive findings and the T-stage by Union Internationale Contre le Cancer (UICC) (6th edition) System, using each sequence separately. The T-stage derived from a single MR sequence was then compared with the T-stage based on the five selected sequences to assess the number and percentage of patients who were being understaged. Therefore, the overall percentage accuracy of each single sequence could be determined. A pair of sequences providing information to achieve almost 100% diagnostic accuracy was then derived. The overall percentage accuracy of five individual sequences of the nasopharynx is as follows: contrast-enhanced (CE) fat suppression (FS) axial T1 (94.8%), CE FS coronal T1 (88.1%), FS axial T2 (85.8%), non-contrast enhanced (NE) axial T1 (78.4%) and NE coronal T1 (77.6%). CE FS axial T1 has the best accuracy. All the structures that are missed in CE FS axial T1 which lead to apparent understaging, are appreciated in NE axial T1-weighted images. Individual sequences supplement each other in the NPC staging. CE FS axial T1 is the most informative individual sequence. Combination of CE FS axial T1 and NE axial T1 of the nasopharynx provides sufficient information to achieve almost 100% diagnostic accuracy in T-staging; therefore, both should be included in the MR-staging protocol. (author)

  19. A two-stage stochastic programming approach for operating multi-energy systems

    DEFF Research Database (Denmark)

    Zeng, Qing; Fang, Jiakun; Chen, Zhe

    2017-01-01

    This paper provides a two-stage stochastic programming approach for joint operating multi-energy systems under uncertainty. Simulation is carried out in a test system to demonstrate the feasibility and efficiency of the proposed approach. The test energy system includes a gas subsystem with a gas...

  20. Technical note: Stage and water width measurement of a mountain stream using a simple time-lapse camera

    Directory of Open Access Journals (Sweden)

    P. Leduc

    2018-01-01

    Full Text Available Remote sensing applied to river monitoring adds complementary information useful for understanding the system behaviour. In this paper, we present a method for visual stage gauging and water surface width measurement using a ground-based time-lapse camera and a fully automatic image analysis algorithm for flow monitoring at a river cross section of a steep, bouldery channel. The remote stage measurement was coupled with a water level logger (pressure transducer on site and shows that the image-based method gives a reliable estimate of the water height variation and daily flow record when validated against the pressure transducer (R = 0.91. From the remotely sensed pictures, we also extracted the water width and show that it is possible to correlate water surface width and stage. The images also provide valuable ancillary information for interpreting and understanding flow hydraulics and site weather conditions. This image-based gauging method is a reliable, informative and inexpensive alternative or adjunct to conventional stage measurement especially for remote sites.

  1. Development of a PET/Cerenkov-light hybrid imaging system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-01-01

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm 3 GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a 22 Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that 18 F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging

  2. New real-time image processing system for IRFPA

    Institute of Scientific and Technical Information of China (English)

    WANG Bing-jian; LIU Shang-qian; CHENG Yu-bao

    2006-01-01

    Influenced by detectors' material,manufacturing technology etc,every detector in infrared focal plane array (IRFPA) will output different voltages even if their input radiation flux is the same.And this is called non-uniformity of IRFPA.At the same time,the high background temperature,low temperature difference between targets and background and the low responsivity of IRFPA result in low contrast of infrared images.So non-uniformity correction and image enhancement are important techniques for IRFPA imaging system.This paper proposes a new real-time infrared image processing system based on Field Programmable Gate Array(FPGA).The system implements non-uniformity correction,image enhancement and video synthesization etc.By using parallel architecture and pipeline technique,the system processing speed is as high as 50Mx12bits per second.It is appropriate greatly to a large IRFPA and a high frame frequency IRFPA imaging system.The system is miniatured in one FPGA.

  3. Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.

    Science.gov (United States)

    Wei, Xiaobo; Liu, Mengjiao; Ding, Yun; Li, Qilin; Cheng, Changhai; Zong, Xian; Yin, Wenming; Chen, Jie; Gu, Wendong

    2018-05-08

    Breast-conserving surgery (BCS) plus postoperative radiotherapy has become the standard treatment for early-stage breast cancer. The aim of this study was to compare the setup accuracy of optical surface imaging by the Sentinel system with cone-beam computerized tomography (CBCT) imaging currently used in our clinic for patients received BCS. Two optical surface scans were acquired before and immediately after couch movement correction. The correlation between the setup errors as determined by the initial optical surface scan and CBCT was analyzed. The deviation of the second optical surface scan from the reference planning CT was considered an estimate for the residual errors for the new method for patient setup correction. The consequences in terms for necessary planning target volume (PTV) margins for treatment sessions without setup correction applied. We analyzed 145 scans in 27 patients treated for early stage breast cancer. The setup errors of skin marker based patient alignment by optical surface scan and CBCT were correlated, and the residual setup errors as determined by the optical surface scan after couch movement correction were reduced. Optical surface imaging provides a convenient method for improving the setup accuracy for breast cancer patient without unnecessary imaging dose.

  4. Radiographic imaging system

    International Nuclear Information System (INIS)

    Davis, L. Jr.; Barrett, H.H.

    1979-01-01

    This invention describes a system for imaging a subject, such as a human being, in which there has been injected a contrast agent which absorbs radiation of a predetermined frequency. The system utilizes a source of high energy radiation such as X or gamma radiation. The source is a composite of first and second radiating materials each of which is arranged in a predetermined pattern or code, each pattern having both luminous and dark regions. In one embodiment, the luminous regions of one pattern are in registration with the dark regions of the other pattern, these regions being spaced apart in an alternative embodiment. The characteristic frequencies of radiation emitted by the first and second materials are respectively lower and higher than the predetermined absorption frequency. A detector of radiation is positioned relative to the subject and the source such that radiation propagating through the subject is incident upon the detector. Since the absorption edge of the contrast agent lies between the two characteristic frequencies of radiation, radiation from the second material is preferentially absorbed by the contrast agent with the result that the contrast agent appears to be illuminated by a coded source while the remainder of the subject may be regarded as illuminated essentially by a uniform uncoded source. Imaging is accomplished by a decoding of a detected coded image. Substances within the subject having other absorption frequencies are not imaged since the radiations of both materials are essentially equally absorbed by the subject so that the source appears uncoded

  5. The experimental study of a two-stage photovoltaic thermal system based on solar trough concentration

    International Nuclear Information System (INIS)

    Tan, Lijun; Ji, Xu; Li, Ming; Leng, Congbin; Luo, Xi; Li, Haili

    2014-01-01

    Highlights: • A two-stage photovoltaic thermal system based on solar trough concentration. • Maximum cell efficiency of 5.21% with the mirror opening width of 57 cm. • With single cycle, maximum temperatures rise in the heating stage is 12.06 °C. • With 30 min multiple cycles, working medium temperature 62.8 °C, increased 28.7 °C. - Abstract: A two-stage photovoltaic thermal system based on solar trough concentration is proposed, in which the metal cavity heating stage is added on the basis of the PV/T stage, and thermal energy with higher temperature is output while electric energy is output. With the 1.8 m 2 mirror PV/T system, the characteristic parameters of the space solar cell under non-concentrating solar radiation and concentrating solar radiation are respectively tested experimentally, and the solar cell output characteristics at different opening widths of concentrating mirror of the PV/T stage under condensation are also tested experimentally. When the mirror opening width was 57 cm, the solar cell efficiency reached maximum value of 5.21%. The experimental platform of the two-stage photovoltaic thermal system was established, with a 1.8 m 2 mirror PV/T stage and a 15 m 2 mirror heating stage, or a 1.8 m 2 mirror PV/T stage and a 30 m 2 mirror heating stage. The results showed that with single cycle, the long metal cavity heating stage would bring lower thermal efficiency, but temperature rise of the working medium is higher, up to 12.06 °C with only single cycle. With 30 min closed multiple cycles, the temperature of the working medium in the water tank was 62.8 °C, with an increase of 28.7 °C, and thermal energy with higher temperature could be output

  6. Staging of gastric adenocarcinoma using two-phase spiral CT: correlation with pathologic staging

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won

    1998-01-01

    To correlate the preoperative staging of gastric adenocarcinoma using two-phase spiral CT with pathologic staging. One hundred and eighty patients with gastric cancers confirmed during surgery underwent two-phase spiral CT, and were evaluated retrospectively. CT scans were obtained in the prone position after ingestion of water. Scans were performed 35 and 80 seconds after the start of infusion of 120mL of non-ionic contrast material with the speed of 3mL/sec. Five mm collimation, 7mm/sec table feed and 5mm reconstruction interval were used. T-and N-stage were determined using spiral CT images, without knowledge of the pathologic results. Pathologic staging was later compared with CT staging. Pathologic T-stage was T1 in 70 cases(38.9%), T2 in 33(18.3%), T3 in 73(40.6%), and T4 in 4(2.2%). Type-I or IIa elevated lesions accouted for 10 of 70 T1 cases(14.3%) and flat or depressed lesions(type IIb, IIc, or III) for 60(85.7%). Pathologic N-stage was NO in 85 cases(47.2%), N1 in 42(23.3%), N2 in 31(17.2%), and N3 in 22(12,2%). The detection rate of early gastric cancer using two-phase spiral CT was 100.0%(10 of 10 cases) among elevated lesions and 78.3%(47 of 60 cases) among flat or depressed lesions. With regard to T-stage, there was good correlation between CT image and pathology in 86 of 180 cases(47.8%). Overstaging occurred in 23.3%(42 of 180 cases) and understaging in 28.9%(52 of 180 cases). With regard to N-stage, good correlation between CT image and pathology was noted in 94 of 180 cases(52.2%). The rate of understaging(31.7%, 57 of 180 cases) was higher than that of overstaging(16.1%, 29 of 180 cases)(p<0.001). The detection rate of early gastric cancer using two-phase spiral CT was 81.4%, and there was no significant difference in detectability between elevated and depressed lesions. Two-phase spiral CT for determing the T-and N-stage of gastric cancer was not effective;it was accurate in abont 50% of cases understaging tended to occur.=20

  7. Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

    OpenAIRE

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun; Yoo, Eun Sang

    2012-01-01

    Purpose Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Materials and Methods Between January 2005 and May 2010, 151 patients underwent radi...

  8. Detection rates in pediatric diagnostic imaging: a picture archive and communication system compared with a web-based imaging system

    International Nuclear Information System (INIS)

    McDonald, L.; Cramer, B.; Barrett, B.

    2006-01-01

    This prospective study assesses whether there are differences in accuracy of interpretation of diagnostic images among users of a picture archive and communication system (PACS) diagnostic workstation, compared with a less costly Web-based imaging system on a personal computer (PC) with a high resolution monitor. One hundred consecutive pediatric chest or abdomen and skeletal X-rays were selected from hospital inpatient and outpatient studies over a 5-month interval. They were classified as normal (n = 32), obviously abnormal (n = 33), or having subtle abnormal findings (n = 35) by 2 senior radiologists who reached a consensus for each individual case. Subsequently, 5 raters with varying degrees of experience independently viewed and interpreted the cases as normal or abnormal. Raters viewed each image 1 month apart on a PACS and on the Web-based PC imaging system. There was no relation between accuracy of detection and the system used to evaluate X-ray images (P = 0.92). The total percentage of incorrect interpretations on the Web-based PC imaging system was 23.2%, compared with 23.6% on the PACS (P = 0.92). For all raters combined, the overall difference in proportion assessed incorrectly on the PACS, compared with the PC system, was not significant at 0.4% (95%CI, -3.5% to 4.3%). The high-resolution Web-based imaging system via PC is an adequate alternative to a PACS clinical workstation. Accordingly, the provision of a more extensive network of workstations throughout the hospital setting could have potentially significant cost savings. (author)

  9. Accuracy of magnetic resonance imaging in the pre-operative staging of rectal adenocarcinoma: Experience from a regional Australian cancer center.

    Science.gov (United States)

    White, Rohen; Ung, Kim Ann; Mathlum, Maitham

    2013-12-01

    Selection of the optimal treatment pathway in patients with rectal adenocarcinoma relies on accurate locoregional staging. This study aims to assess the accuracy of staging with magnetic resonance imaging (MRI) and in particular, its accuracy in differentiating patients with early stage disease from those with more advanced disease who benefit from a different treatment approach. Patients who were staged with MRI and received surgery as the first line of treatment for biopsy-proven adenocarcinoma of the rectum were identified. Comparison was made between the clinical stage on MRI and the pathological stage of the surgical specimen. The sensitivity, specificity and overall accuracy of MRI was assessed. In all, 58 eligible patients were identified. In 31% of patients, the extent of disease was underrepresented on preoperative MRI. Sensitivity, specificity and overall accuracy of anorectal MRI in detecting stage II/III disease status in this cohort was 59, 71 and 62%, respectively. MRI underestimated the pathological stage in many patients in this series who may have benefited from the addition of neoadjuvant radiotherapy to their management. This study supports further refinement of preoperative staging and demonstrates that impressive results from highly controlled settings may be difficult to reproduce in community practice. © 2012 Wiley Publishing Asia Pty Ltd.

  10. Performance assessment and transient optimization of air precooling in multi-stage solid desiccant air conditioning systems

    International Nuclear Information System (INIS)

    Gadalla, Mohamed; Saghafifar, Mohammad

    2016-01-01

    Highlights: • Studying three two-stage solid desiccant cooling systems using Maisotsenko cooler. • Proposing precooling to improve two-stage desiccant systems’ COP for humid climates. • Performing transient analysis for a two-stage solid desiccant cooler in UAE. • Optimizing daily performance of a two-stage solid desiccant cooler for UAE. - Abstract: Renewable energy is one of the most promising solutions to both energy and global warming crisis. Energy consumption can be minimized considerably by utilizing solar energy in air conditioning systems operation. One of the popular solar air conditioning technologies is desiccant air conditioning. Nonetheless, conventional desiccant air conditioning systems have a relatively low coefficient of performance (COP). In consequence, two-stage desiccant air-conditioning systems are proposed to improve desiccant air conditioning systems’ COP. Moreover, a recently commercialized cooling method named Maisotsenko cooling cycle which is capable of cooling air near to its dew point temperature is considered to be integrated within the proposed multi-stage desiccant cooling systems. In this paper, three new two-stage desiccant air conditioning systems incorporating Maisotsenko cooling cycle are proposed and investigated in details for hot and humid climates such as UAE. Furthermore, air precooling is considered to improve two stage desiccant air conditioning systems’ COP. Moreover, full transient analysis and optimization are carried out in UAE within June–October. The proposed system can minimize the required solar heating during noon time as the ambient air dry bulb temperature rises. Average COP of the system during electricity load peak hours (10:00–14:00) for all five considered and combined months is 1.77. Average rate of heat input required to operate the system and average building cooling load are determined to be 100.3 kW and 46.2 kW, respectively. Therefore, system average COP is computed to be 0.46.

  11. Imaging in the diagnosis of chronic pancreatitis

    Directory of Open Access Journals (Sweden)

    Vasile D. Balaban

    2014-12-01

    Full Text Available Chronic pancreatitis is characterised by progressive and irreversible damage of the pancreatic parenchyma and ductal system, which leads to chronic pain, loss of endocrine and exocrine functions. Clinically, pancreatic exocrine insufficiency becomes apparent only after 90% of the parenchima has been lost. Despite the simple definition, diagnosing chronic pancreatitis remains a challenge, especially for early stage disease. Because pancreatic function tests can be normal until late stages and have significant limitations, there is an incresing interest in the role of imaging techniques for the diagnosis of chronic pancreatitis. In this article we review the utility and accuracy of different imaging methods in the diagnosis of chronic pancreatitis, focusing on the role of advanced imaging (magnetic resonance imaging, endoscopic retrograde cholangiopancreatography and endoscopic ultrasound.

  12. Reward, motivation, and emotion systems associated with early-stage intense romantic love.

    Science.gov (United States)

    Aron, Arthur; Fisher, Helen; Mashek, Debra J; Strong, Greg; Li, Haifang; Brown, Lucy L

    2005-07-01

    Early-stage romantic love can induce euphoria, is a cross-cultural phenomenon, and is possibly a developed form of a mammalian drive to pursue preferred mates. It has an important influence on social behaviors that have reproductive and genetic consequences. To determine which reward and motivation systems may be involved, we used functional magnetic resonance imaging and studied 10 women and 7 men who were intensely "in love" from 1 to 17 mo. Participants alternately viewed a photograph of their beloved and a photograph of a familiar individual, interspersed with a distraction-attention task. Group activation specific to the beloved under the two control conditions occurred in dopamine-rich areas associated with mammalian reward and motivation, namely the right ventral tegmental area and the right postero-dorsal body and medial caudate nucleus. Activation in the left ventral tegmental area was correlated with facial attractiveness scores. Activation in the right anteromedial caudate was correlated with questionnaire scores that quantified intensity of romantic passion. In the left insula-putamen-globus pallidus, activation correlated with trait affect intensity. The results suggest that romantic love uses subcortical reward and motivation systems to focus on a specific individual, that limbic cortical regions process individual emotion factors, and that there is localization heterogeneity for reward functions in the human brain.

  13. A two-stage stochastic programming model for the optimal design of distributed energy systems

    International Nuclear Information System (INIS)

    Zhou, Zhe; Zhang, Jianyun; Liu, Pei; Li, Zheng; Georgiadis, Michael C.; Pistikopoulos, Efstratios N.

    2013-01-01

    Highlights: ► The optimal design of distributed energy systems under uncertainty is studied. ► A stochastic model is developed using genetic algorithm and Monte Carlo method. ► The proposed system possesses inherent robustness under uncertainty. ► The inherent robustness is due to energy storage facilities and grid connection. -- Abstract: A distributed energy system is a multi-input and multi-output energy system with substantial energy, economic and environmental benefits. The optimal design of such a complex system under energy demand and supply uncertainty poses significant challenges in terms of both modelling and corresponding solution strategies. This paper proposes a two-stage stochastic programming model for the optimal design of distributed energy systems. A two-stage decomposition based solution strategy is used to solve the optimization problem with genetic algorithm performing the search on the first stage variables and a Monte Carlo method dealing with uncertainty in the second stage. The model is applied to the planning of a distributed energy system in a hotel. Detailed computational results are presented and compared with those generated by a deterministic model. The impacts of demand and supply uncertainty on the optimal design of distributed energy systems are systematically investigated using proposed modelling framework and solution approach.

  14. Comparison of single-stage and temperature-phased two-stage anaerobic digestion of oily food waste

    International Nuclear Information System (INIS)

    Wu, Li-Jie; Kobayashi, Takuro; Li, Yu-You; Xu, Kai-Qin

    2015-01-01

    Highlights: • A single-stage and two two-stage anaerobic systems were synchronously operated. • Similar methane production 0.44 L/g VS_a_d_d_e_d from oily food waste was achieved. • The first stage of the two-stage process became inefficient due to serious pH drop. • Recycle favored the hythan production in the two-stage digestion. • The conversion of unsaturated fatty acids was enhanced by recycle introduction. - Abstract: Anaerobic digestion is an effective technology to recover energy from oily food waste. A single-stage system and temperature-phased two-stage systems with and without recycle for anaerobic digestion of oily food waste were constructed to compare the operation performances. The synchronous operation indicated the similar ability to produce methane in the three systems, with a methane yield of 0.44 L/g VS_a_d_d_e_d. The pH drop to less than 4.0 in the first stage of two-stage system without recycle resulted in poor hydrolysis, and methane or hydrogen was not produced in this stage. Alkalinity supplement from the second stage of two-stage system with recycle improved pH in the first stage to 5.4. Consequently, 35.3% of the particulate COD in the influent was reduced in the first stage of two-stage system with recycle according to a COD mass balance, and hydrogen was produced with a percentage of 31.7%, accordingly. Similar solids and organic matter were removed in the single-stage system and two-stage system without recycle. More lipid degradation and the conversion of long-chain fatty acids were achieved in the single-stage system. Recycling was proved to be effective in promoting the conversion of unsaturated long-chain fatty acids into saturated fatty acids in the two-stage system.

  15. Multispectral Panoramic Imaging System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — International Electronic Machines Corporation, a leader in the design of precision imaging systems, will develop an innovative multispectral, panoramic imaging...

  16. Medical image information system 2001. Development of the medical image information system to risk management- Medical exposure management

    International Nuclear Information System (INIS)

    Kuranishi, Makoto; Kumagai, Michitomo; Shintani, Mitsuo

    2000-01-01

    This paper discusses the methods and systems for optimizing the following supplements 10 and 17 for national health and medical care. The supplements 10 and 17 of DICOM (digital imaging and communications in medicine) system, which is now under progress for the purpose to keep compatibility within medical image information system as an international standard, are important for making the cooperation between HIS (hospital information system)/RIS (radiation information system) and modality (imaging instruments). Supplement 10 concerns the system to send the information of patients and their orders through HIS/RIS to modality and 17, the information of modality performed procedure step (MPPS) to HIS/RIS. The latter defines to document patients' exposure, a part of which has not been recognized in Japan. Thus the medical information system can be useful for risk-management of medical exposure in future. (K.H.)

  17. Medical image information system 2001. Development of the medical image information system to risk management- Medical exposure management

    Energy Technology Data Exchange (ETDEWEB)

    Kuranishi, Makoto; Kumagai, Michitomo; Shintani, Mitsuo [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    2000-12-01

    This paper discusses the methods and systems for optimizing the following supplements 10 and 17 for national health and medical care. The supplements 10 and 17 of DICOM (digital imaging and communications in medicine) system, which is now under progress for the purpose to keep compatibility within medical image information system as an international standard, are important for making the cooperation between HIS (hospital information system)/RIS (radiation information system) and modality (imaging instruments). Supplement 10 concerns the system to send the information of patients and their orders through HIS/RIS to modality and 17, the information of modality performed procedure step (MPPS) to HIS/RIS. The latter defines to document patients' exposure, a part of which has not been recognized in Japan. Thus the medical information system can be useful for risk-management of medical exposure in future. (K.H.)

  18. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  19. Filtering and deconvolution for bioluminescence imaging of small animals

    International Nuclear Information System (INIS)

    Akkoul, S.

    2010-01-01

    This thesis is devoted to analysis of bioluminescence images applied to the small animal. This kind of imaging modality is used in cancerology studies. Nevertheless, some problems are related to the diffusion and the absorption of the tissues of the light of internal bioluminescent sources. In addition, system noise and the cosmic rays noise are present. This influences the quality of the images and makes it difficult to analyze. The purpose of this thesis is to overcome these disturbing effects. We first have proposed an image formation model for the bioluminescence images. The processing chain is constituted by a filtering stage followed by a deconvolution stage. We have proposed a new median filter to suppress the random value impulsive noise which corrupts the acquired images; this filter represents the first block of the proposed chain. For the deconvolution stage, we have performed a comparative study of various deconvolution algorithms. It allowed us to choose a blind deconvolution algorithm initialized with the estimated point spread function of the acquisition system. At first, we have validated our global approach by comparing our obtained results with the ground truth. Through various clinical tests, we have shown that the processing chain allows a significant improvement of the spatial resolution and a better distinction of very close tumor sources, what represents considerable contribution for the users of bioluminescence images. (author)

  20. ORIS: the Oak Ridge Imaging System program listings

    International Nuclear Information System (INIS)

    Bell, P.R.; Dougherty, J.M.

    1978-04-01

    The Oak Ridge Imaging System (ORIS) is a general purpose access, storage, processing and display system for nuclear medicine imaging with rectilinear scanner and gamma camera. This volume contains listings of the PDP-8/E version of ORIS Version 2. The system is designed to run under the Digital Equipment Corporation's OS/8 monitor in 16K or more words of core. System and image file mass storage is on RK8E disk; longer-time image file storage is provided on DECtape. Another version of this program exists for use with the RF08 disk, and a more limited version is for DECtape only. This latter version is intended for non-medical imaging

  1. Space-Ready Advanced Imaging System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II effort Toyon will increase the state-of-the-art for video/image systems. This will include digital image compression algorithms as well as system...

  2. Staging of fibrosis in experimental non-alcoholic steatohepatitis by quantitative molecular imaging in rat models

    International Nuclear Information System (INIS)

    Schnabl, Bernd; Farshchi-Heydari, Salman; Loomba, Rohit; Mattrey, Robert F.; Hoh, Carl K.; Sirlin, Claude B.; Brenner, David A.; Behling, Cynthia A.; Vera, David R.

    2016-01-01

    Objectives: The aim of this study was to test the ability of hepatocyte-specific functional imaging to stage fibrosis in experimental rat models of liver fibrosis and progressive NASH. Using ROC analysis we tested the ability of a functional imaging metric to discriminate early (F1) from moderate (F2) fibrosis in the absence and presence of non-alcoholic steatohepatitis, which has not been achieved by any modality other than biopsy. Methods: Galactosyl Human Serum Albumin (GSA) was radiolabeled with the positron-emitter, 68 Ga, and injected (i.v., 45–95 μCi, 1.5 pmol/g TBW) into 44 healthy, 19 DEN-, and 22 CDAA-treated male rats. Quantification of liver function was achieved by calculating T90, defined as the time for the liver to accumulate 90 percent of the [ 68 Ga]GSA plateau value. All livers were excised immediately after imaging and prepared for a “blinded” histologic examination, which included fibrosis and fat content scores. Two sets of fibrosis scores were recorded for all of animals. The dominant fibrosis stage was recorded as the “Dominant Pattern” score and the “Maximum Pattern” score was assigned if a smaller distinct region with a higher fibrosis score was observed. Results: Animals with Dominant Pattern F0–F1 liver fibrosis (D − = 39) demonstrated significantly (P < 0.0001) faster accumulation of [ 68 Ga]GSA (2.40 ± 0.52 min) than those with moderate to advanced Dominant Pattern fibrosis F2 and F4 (D + = 26) (3.48 ± 1.01 min). ROC analysis (F0–F1 vs F2–F4) produced an area under the binormal curve (AUC) of 0.867 ± 0.045. Twenty-seven of the 65 rats had small regions with higher fibrosis scores. Six of these Maximum Pattern scores reclassified the animals from D − to D + . ROC analysis of F0–F1 versus F2–F4 rats without liver fat produced AUCs of 0.881 ± 0.053 for the Dominant Pattern Score and 0.944 ± 0.035 for the Maximum Pattern Score. Conclusions: PET Functional Imaging of [ 68 Ga]GSA accurately discriminates

  3. An integrated compact airborne multispectral imaging system using embedded computer

    Science.gov (United States)

    Zhang, Yuedong; Wang, Li; Zhang, Xuguo

    2015-08-01

    An integrated compact airborne multispectral imaging system using embedded computer based control system was developed for small aircraft multispectral imaging application. The multispectral imaging system integrates CMOS camera, filter wheel with eight filters, two-axis stabilized platform, miniature POS (position and orientation system) and embedded computer. The embedded computer has excellent universality and expansibility, and has advantages in volume and weight for airborne platform, so it can meet the requirements of control system of the integrated airborne multispectral imaging system. The embedded computer controls the camera parameters setting, filter wheel and stabilized platform working, image and POS data acquisition, and stores the image and data. The airborne multispectral imaging system can connect peripheral device use the ports of the embedded computer, so the system operation and the stored image data management are easy. This airborne multispectral imaging system has advantages of small volume, multi-function, and good expansibility. The imaging experiment results show that this system has potential for multispectral remote sensing in applications such as resource investigation and environmental monitoring.

  4. Trus and MRI should not be used to stage patients with prostate cancer: an outcome based analysis

    International Nuclear Information System (INIS)

    Pinover, W. H.; Hanlon, A. L.; Kaplan, E. J.; Lee, W. R.; Hanks, G. E.

    1995-01-01

    , upstaging by TRUS/MRI does not separate patients into groups with different prognoses. The AJCC staging system should consider eliminating the recommendation to include imaging in staging. If stage is used as a prognostic indicator in comparing results this should be restricted to palpation stage and further emphasizes the need for a biochemical PSA level based staging system. Diagnostic imaging for staging localized prostate disease is not indicated and it's elimination would result in significant savings in healthcare costs

  5. Development of an integrated filing system for endoscopic images.

    Science.gov (United States)

    Fujino, M A; Ikeda, M; Yamamoto, Y; Kinose, T; Tachikawa, H; Morozumi, A; Sano, S; Kojima, Y; Nakamura, T; Kawai, T

    1991-01-01

    A new integrated filing system for endoscopic images has been developed, comprising a main image filing system and subsystems located at different stations. A hybrid filing system made up of both digital and analog filing devices was introduced to construct this system that combines the merits of the two filing methods. Each subsystem provided with a video processor, is equipped with a digital filing device, and routine images were recorded in the analog image filing device of the main system. The use of a multi-input adapter enabled simultaneous input of analog images from up to 8 video processors. Recorded magneto-optical disks make it possible to recall the digital images at any station in the hospital; the disks are copied without image degradation and also utilised for image processing. This system promises reliable storage and integrated, efficient management of endoscopic information. It also costs less to install than the so-called PACS (picture archiving and communication system), which connects all the stations of the hospital using optical fiber cables.

  6. Recent developments of MR imaging system and future trends

    International Nuclear Information System (INIS)

    Fujieda, Kunimi

    1996-01-01

    Because MR imaging technique has no limitation of slice direction, uses none of mechanically moving components and can employ electronic scanning method for data acquisition, the most advanced electronics and CPU techniques have been applied to develop MR imaging systems. Along with pursuance of better equipment performance as clinical diagnostic equipment, cost reduction, improvement of operability and safety, easy siting, comfortable examination and economical operation cost by remarkable reduction of running cost have become important factors in development of MR imaging system. From this viewpoint, MR imaging systems incorporating an open gantry with a relatively low field strength and of vertical field system have been developed recently and they are being accepted as clinically useful equipment. The vertical field, open gantry system has an optimum structure capable of performing interventional imaging, thus clinical application of the system have been actively attempted. Thanks to recent development of various MRI techniques, image quality quite acceptable for routine clinical diagnosis can now be obtained by using the systems with permanent magnet and resistive magnet. Thus, it is considered that evaluation of not only equipment performance but also the total performances of the MR imaging system as described above will become important. The MR imaging technique has a possibility to substitute itself for other conventional imaging modalities because the technique can visualize physiological and metabolic functions in addition to morphological imaging. It is expected that application of MR imaging modality will be further expanded by continuous investigation of applicable clinical fields and development of imaging technologies. (J.P.N.)

  7. A Two-stage DC-DC Converter for the Fuel Cell-Supercapacitor Hybrid System

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2009-01-01

    A wide input range multi-stage converter is proposed with the fuel cells and supercapacitors as a hybrid system. The front-end two-phase boost converter is used to optimize the output power and to reduce the current ripple of fuel cells. The supercapacitor power module is connected by push...... and designed. A 1kW prototype controlled by TMS320F2808 DSP is built in the lab. Simulation and experimental results confirm the feasibility of the proposed two stage dc-dc converter system.......-pull-forward half bridge (PPFHB) converter with coupled inductors in the second stage to handle the slow transient response of the fuel cells and realize the bidirectional power flow control. Moreover, this cascaded structure simplifies the power management. The control strategy for the whole system is analyzed...

  8. An integrated multimodality image-guided robot system for small-animal imaging research

    International Nuclear Information System (INIS)

    Hsu, Wen-Lin; Hsin Wu, Tung; Hsu, Shih-Ming; Chen, Chia-Lin; Lee, Jason J.S.; Huang, Yung-Hui

    2011-01-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO 2 probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153±0.042 mm of desired placement; the phantom simulation errors were within 0.693±0.128 mm. In small-animal studies, the pO 2 probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  9. Two-stage energy storage equalization system for lithium-ion battery pack

    Science.gov (United States)

    Chen, W.; Yang, Z. X.; Dong, G. Q.; Li, Y. B.; He, Q. Y.

    2017-11-01

    How to raise the efficiency of energy storage and maximize storage capacity is a core problem in current energy storage management. For that, two-stage energy storage equalization system which contains two-stage equalization topology and control strategy based on a symmetric multi-winding transformer and DC-DC (direct current-direct current) converter is proposed with bidirectional active equalization theory, in order to realize the objectives of consistent lithium-ion battery packs voltages and cells voltages inside packs by using a method of the Range. Modeling analysis demonstrates that the voltage dispersion of lithium-ion battery packs and cells inside packs can be kept within 2 percent during charging and discharging. Equalization time was 0.5 ms, which shortened equalization time of 33.3 percent compared with DC-DC converter. Therefore, the proposed two-stage lithium-ion battery equalization system can achieve maximum storage capacity between lithium-ion battery packs and cells inside packs, meanwhile efficiency of energy storage is significantly improved.

  10. Imaging mass spectrometry (IMS) of cortical lipids from preclinical to severe stages of Alzheimer's disease.

    Science.gov (United States)

    Gónzalez de San Román, E; Manuel, I; Giralt, M T; Ferrer, I; Rodríguez-Puertas, R

    2017-09-01

    Alzheimer's disease (AD) is a progressive neurodegenerative disease affecting millions of patients worldwide. Previous studies have demonstrated alterations in the lipid composition of lipid extracts from plasma and brain samples of AD patients. However, there is no consensus regarding the qualitative and quantitative changes of lipids in brains from AD patients. In addition, the recent developments in imaging mass spectrometry methods are leading to a new stage in the in situ analysis of lipid species in brain tissue slices from human postmortem samples. The present study uses the matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS), permitting the direct anatomical analysis of lipids in postmortem brain sections from AD patients, which are compared with the intensity of the lipid signal in samples from matched subjects with no neurological diseases. The frontal cortex samples from AD patients were classified in three groups based on Braak's histochemical criteria, ranging from non-cognitively impaired patients to those severely affected. The main results indicate a depletion of different sulfatide lipid species from the earliest stages of the disease in both white and gray matter areas of the frontal cortex. Therefore, the decrease in sulfatides in cortical areas could be considered as a marker of the disease, but may also indicate neurochemical modifications related to the pathogenesis of the disease. This article is part of a Special Issue entitled: Membrane Lipid Therapy: Drugs Targeting Biomembranes edited by Pablo V. Escribá. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Utility of CT after sonography for suspected appendicitis in children: integration of a clinical scoring system with a staged imaging protocol.

    Science.gov (United States)

    Srinivasan, Abhay; Servaes, Sabah; Peña, Andrès; Darge, Kassa

    2015-02-01

    To improve diagnosis of pediatric appendicitis, many institutions have implemented a staged imaging protocol utilizing ultrasonography (US) first and then computed tomography (CT). A substantial number of children with suspected appendicitis undergo CT after US, and the efficient and accurate diagnosis of pediatric appendicitis continues to be challenging. The objective of the study is to characterize the utility of CT following US for diagnosis of pediatric appendicitis, in conjunction with a clinical appendicitis score (AS). Imaging studies of children with suspected appendicitis who underwent CT after US in an imaging protocol were retrospectively reviewed by three radiologists in consensus. Chart review derived the AS (range 0-10) and obtained the patient diagnosis and disposition, and an AS was applied to each patient. Clinical and radiologic data were analyzed to assess the yield of CT after US. Studies of 211 children (mean age 11.3 years) were included. The positive threshold for AS was determined to be 6 out of 10. When AS and US were concordant (N = 140), the sensitivity and specificity of US were similar to CT. When AS and US were discordant (N = 71) and also when AS ≥ 6 (N = 84), subsequent CT showed superior sensitivity and specificity to US alone. In the subset where US showed neither the appendix nor inflammatory change in the right lower quadrant (126/211, 60 % of scans), when AS 6 (kg/year, P < 0.001) and after-hours (1700 -0730 hours) performance of US (P < 0.001). Results suggest that the appendicitis score has utility in guiding an imaging protocol and support the contention that non-visualization of the appendix on US is not intrinsically non-diagnostic. There was little benefit to additional CT when AS < 6 and US did not show the appendix or evidence of inflammation; this would have avoided CT in 140/211 (66 %) patients. CT demonstrated benefit when AS ≥ 6, suggesting that cases with AS ≥ 6 and

  12. Imaging system for creating 3D block-face cryo-images of whole mice

    Science.gov (United States)

    Roy, Debashish; Breen, Michael; Salvado, Olivier; Heinzel, Meredith; McKinley, Eliot; Wilson, David

    2006-03-01

    We developed a cryomicrotome/imaging system that provides high resolution, high sensitivity block-face images of whole mice or excised organs, and applied it to a variety of biological applications. With this cryo-imaging system, we sectioned cryo-preserved tissues at 2-40 μm thickness and acquired high resolution brightfield and fluorescence images with microscopic in-plane resolution (as good as 1.2 μm). Brightfield images of normal and pathological anatomy show exquisite detail, especially in the abdominal cavity. Multi-planar reformatting and 3D renderings allow one to interrogate 3D structures. In this report, we present brightfield images of mouse anatomy, as well as 3D renderings of organs. For BPK mice model of polycystic kidney disease, we compared brightfield cryo-images and kidney volumes to MRI. The color images provided greater contrast and resolution of cysts as compared to in vivo MRI. We note that color cryo-images are closer to what a researcher sees in dissection, making it easier for them to interpret image data. The combination of field of view, depth of field, ultra high resolution and color/fluorescence contrast enables cryo-image volumes to provide details that cannot be found through in vivo imaging or other ex vivo optical imaging approaches. We believe that this novel imaging system will have applications that include identification of mouse phenotypes, characterization of diseases like blood vessel disease, kidney disease, and cancer, assessment of drug and gene therapy delivery and efficacy and validation of other imaging modalities.

  13. Bladder cancer: Evaluation of staging accuracy using dynamic MRI

    International Nuclear Information System (INIS)

    Rajesh, A.; Sokhi, H.K.; Fung, R.; Mulcahy, K.A.; Bankart, M.J.G.

    2011-01-01

    Aim: To assess the accuracy of magnetic resonance imaging (MRI) in staging bladder cancer and to assess whether dynamic gadolinium-enhanced sequences have any added benefit in staging. Materials and methods: Over a 22 month period, the MRI findings of 100 consecutive patients with histologically proven transitional cell carcinoma (TCC) of the bladder were reviewed. The T stage was assessed independently on T2-weighted imaging alone and in combination with gadolinium-enhanced MRI. The final histological diagnosis was considered the reference standard. Statistical analysis was performed to ascertain stage-by-stage accuracy. Accuracy of MRI in differentiating superficial (≤T1) from invasive (≥T2) and in differentiating organ-confined (≤T2) from non-organ-confined (≥T3) disease was assessed. Results: On a stage-by-stage basis, tumours were correctly staged using MRI in 63% of patients (observed agreement = 0.63, weighted kappa = 0.57). The sensitivity and specificity of MRI to differentiate between superficial (≤T1) from invasive (≥T2) disease was 78.2 and 93.3%. The observed agreement for this group was 85% (kappa = 70%; p < 0.0001). The sensitivity and specificity of MRI to differentiate between organ-confined (≤T2) from non-organ confined (≥T3) disease was 90.5 and 60%. The observed agreement for this group was 89% (kappa = 30%; p < 0.01). Gadolinium-enhanced images improved staging in only three patients. Conclusion: In the present study MRI was found to be a moderately accurate tool in assessing the T stage. Agreement on a stage-by-stage basis was good. Agreement for differentiating between non-invasive versus muscle-invasive disease was good and that for organ-confined versus non-organ-confined disease was fair. Routine use of gadolinium-enhanced images is not routinely required.

  14. Bladder cancer: Evaluation of staging accuracy using dynamic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rajesh, A., E-mail: arajesh27@hotmail.com [Department of Radiology, University Hospitals of Leicester NHS Trust, Leicester General Hospital (United Kingdom); Sokhi, H.K.; Fung, R.; Mulcahy, K.A. [Department of Radiology, University Hospitals of Leicester NHS Trust, Leicester General Hospital (United Kingdom); Bankart, M.J.G. [Department of Health Sciences, University of Leicester, Leicester (United Kingdom)

    2011-12-15

    Aim: To assess the accuracy of magnetic resonance imaging (MRI) in staging bladder cancer and to assess whether dynamic gadolinium-enhanced sequences have any added benefit in staging. Materials and methods: Over a 22 month period, the MRI findings of 100 consecutive patients with histologically proven transitional cell carcinoma (TCC) of the bladder were reviewed. The T stage was assessed independently on T2-weighted imaging alone and in combination with gadolinium-enhanced MRI. The final histological diagnosis was considered the reference standard. Statistical analysis was performed to ascertain stage-by-stage accuracy. Accuracy of MRI in differentiating superficial ({<=}T1) from invasive ({>=}T2) and in differentiating organ-confined ({<=}T2) from non-organ-confined ({>=}T3) disease was assessed. Results: On a stage-by-stage basis, tumours were correctly staged using MRI in 63% of patients (observed agreement = 0.63, weighted kappa = 0.57). The sensitivity and specificity of MRI to differentiate between superficial ({<=}T1) from invasive ({>=}T2) disease was 78.2 and 93.3%. The observed agreement for this group was 85% (kappa = 70%; p < 0.0001). The sensitivity and specificity of MRI to differentiate between organ-confined ({<=}T2) from non-organ confined ({>=}T3) disease was 90.5 and 60%. The observed agreement for this group was 89% (kappa = 30%; p < 0.01). Gadolinium-enhanced images improved staging in only three patients. Conclusion: In the present study MRI was found to be a moderately accurate tool in assessing the T stage. Agreement on a stage-by-stage basis was good. Agreement for differentiating between non-invasive versus muscle-invasive disease was good and that for organ-confined versus non-organ-confined disease was fair. Routine use of gadolinium-enhanced images is not routinely required.

  15. Acute pancreatitis: staging with CT

    International Nuclear Information System (INIS)

    Gialeli, E.; Petrocheilou, G.; Georgaki, S.; Tzemailas, I.; Adraktas, A.; Charilas, G.; Patsiogiannis, V.

    2012-01-01

    Full text: Introduction: Computed Tomography (CT) is the imaging modality of choice for the diagnosis and staging of acute pancreatitis and its complications. Objectives and tasks: The purpose of this presentation is to demonstrate the findings in CT images which are useful for staging acute pancreatitis according to Balthazar, their significance and restrictions. Materials and methods: CT images from patients who were referred to our Department for an abdominal CT scan for the diagnosis or/and staging of acute pancreatitis were retrospectively studied. Results: In acute pancreatitis, CT helps to stage the severity of inflammatory process, to detect pancreatic necrosis and to depict local complications. CT severity index (CTSI), which was proposed by Balthazar et al, combines the grade of pancreatitis with the extent of pancreatic necrosis assigning points to the patients in order to find the severity index which scales from 0-10. More points are given for a higher grade of pancreatitis and for more extensive necrosis. Types of pancreatitis according to CTSI are: interstitial (Balthazar grade A-C), exudative (Balthazar grade D or E), necrotising (Balthazar grade E, CTSI:10) and central gland necrotising. Patients with pancreatitis but no collections or necrosis have an interstitial (mild) pancreatitis. In exudative pancreatitis there is normal enhancement of the entire pancreas associated with extensive peripancreatic collections. Necrotizing (severe) pancreatitis is characterized by protacted clinical course, high incidence of local complications and high mortality rate. Central gland necrosis is a subtype of necrotizing pancreatitis. Conclusions: The combination of CT imaging and clinical and laboratory evaluation allows the early diagnosis of acute pancreatitis. Acute pancreatitis may vary from a mild uneventful disease to a severe life-threatening illness with multisystemic organ failure. Thus, it is crucial to identify patients who are at high risk of severe

  16. Design of optically stable image reflector system.

    Science.gov (United States)

    Tsai, Chung-Yu

    2013-08-01

    The design of a partially optically stable (POS) reflector system, in which the exit ray direction and image pose are unchanged as the reflector system rotates about a specific directional vector, was presented in an earlier study by the current group [Appl. Phys. B100, 883-890 (2010)]. The present study further proposes an optically stable image (OSI) reflector system, in which not only is the optical stability property of the POS system retained, but the image position and total ray path length are also fixed. An analytical method is proposed for the design of OSI reflector systems comprising multiple reflectors. The validity of the proposed approach is demonstrated by means of two illustrative examples.

  17. Target tracking system based on preliminary and precise two-stage compound cameras

    Science.gov (United States)

    Shen, Yiyan; Hu, Ruolan; She, Jun; Luo, Yiming; Zhou, Jie

    2018-02-01

    Early detection of goals and high-precision of target tracking is two important performance indicators which need to be balanced in actual target search tracking system. This paper proposed a target tracking system with preliminary and precise two - stage compound. This system using a large field of view to achieve the target search. After the target was searched and confirmed, switch into a small field of view for two field of view target tracking. In this system, an appropriate filed switching strategy is the key to achieve tracking. At the same time, two groups PID parameters are add into the system to reduce tracking error. This combination way with preliminary and precise two-stage compound can extend the scope of the target and improve the target tracking accuracy and this method has practical value.

  18. Performance assessment of imaging plates for the JHR transfer Neutron Imaging System

    Science.gov (United States)

    Simon, E.; Guimbal, P. AB(; )

    2018-01-01

    The underwater Neutron Imaging System to be installed in the Jules Horowitz Reactor (JHR-NIS) is based on a transfer method using a neutron activated beta-emitter like Dysprosium. The information stored in the converter is to be offline transferred on a specific imaging system, still to be defined. Solutions are currently under investigation for the JHR-NIS in order to anticipate the disappearance of radiographic films commonly used in these applications. We report here the performance assessment of Computed Radiography imagers (Imaging Plates) performed at LLB/Orphée (CEA Saclay). Several imaging plate types are studied, in one hand in the configuration involving an intimate contact with an activated dysprosium foil converter: Fuji BAS-TR, Fuji UR-1 and Carestream Flex XL Blue imaging plates, and in the other hand by using a prototypal imaging plate doped with dysprosium and thus not needing any contact with a separate converter foil. The results for these imaging plates are compared with those obtained with gadolinium doped imaging plate used in direct neutron imaging (Fuji BAS-ND). The detection performances of the different imagers are compared regarding resolution and noise. The many advantages of using imaging plates over radiographic films (high sensitivity, linear response, high dynamic range) could palliate its lower intrinsic resolution.

  19. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.

    Science.gov (United States)

    Mao, Weihua; Speiser, Michael; Medin, Paul; Papiez, Lech; Solberg, Timothy; Xing, Lei

    2011-05-01

    Several linacs with integrated kilovoltage (kV) imaging have been developed for delivery of image guided radiation therapy (IGRT). High geometric accuracy and coincidence of kV imaging systems and megavoltage (MV) beam delivery are essential for successful image guidance. A geometric QA tool has been adapted for routine QA for evaluating and characterizing the geometric accuracy of kV and MV cone-beam imaging systems. The purpose of this work is to demonstrate the application of methodology to routine QA across three IGRT-dedicated linac platforms. It has been applied to a Varian Trilogy (Varian Medical Systems, Palo Alto, CA), an Elekta SynergyS (Elekta, Stockholm, Sweden), and a Brainlab Vero (Brainlab AG, Feldkirchen, Germany). Both the Trilogy and SynergyS linacs are equipped with a retractable kV x-ray tube and a flat panel detector. The Vero utilizes a rotating, rigid ring structure integrating a MV x-ray head mounted on orthogonal gimbals, an electronic portal imaging device (EPID), two kV x-ray tubes, and two fixed flat panel detectors. This dual kV imaging system provides orthogonal radiographs, CBCT images, and real-time fluoroscopic monitoring. Two QA phantoms were built to suit different field sizes. Projection images of a QA phantom were acquired using MV and kV imaging systems at a series of gantry angles. Software developed for this study was used to analyze the projection images and calculate nine geometric parameters for each projection. The Trilogy was characterized five times over one year, while the SynergyS was characterized four times and the Vero once. Over 6500 individual projections were acquired and analyzed. Quantitative geometric parameters of both MV and kV imaging systems, as well as the isocenter consistency of the imaging systems, were successfully evaluated. A geometric tool has been successfully implemented for calibration and QA of integrated kV and MV across a variety of radiotherapy platforms. X-ray source angle deviations up to

  20. Magnetic resonance imaging of the larynx

    International Nuclear Information System (INIS)

    Oleaga, L.

    2001-01-01

    Larynx and hypopharynx represent difficult anatomical structures to evaluate by imaging. Pathological processes inflammatory conditions and neoplasms are frequently found specially neoplasms. The most common tumor originating in this region is squamous cell carcinoma that represents 90%, of malignancies, magnetic Resonance Imaging (MRI) is used for staging of those tumors. In our study we evaluate the technique used for MRI studies as well as the anatomy of the larynx, hypopharynx and nodes and the different classification system used for neck nodes. We also analyze the different types of neoplasm that can be found being and malignant and the use of MRI for staging neoplasms. Clinical and laryngoscope staging of laryngeal tumors is not accurate if fails to demonstrate deep submucosal and laryngeal spaces invasion (pre-epi glottic. para laryngeal, para glottic, anterior commissures posterior commissure and sub glottis) as well as cartilage infiltration and extra laryngeal extension. We need accurate imaging diagnostic methods like MRI to evaluate the extension of tumors. (Author) 38 refs

  1. Experiments for Multi-Stage Processes

    DEFF Research Database (Denmark)

    Tyssedal, John; Kulahci, Murat

    2015-01-01

    Multi-stage processes are very common in both process and manufacturing industries. In this article we present a methodology for designing experiments for multi-stage processes. Typically in these situations the design is expected to involve many factors from different stages. To minimize...... the required number of experimental runs, we suggest using mirror image pairs of experiments at each stage following the first. As the design criterion, we consider their projectivity and mainly focus on projectivity 3 designs. We provide the methodology for generating these designs for processes with any...

  2. High-Resolution Imaging of Parafoveal Cones in Different Stages of Diabetic Retinopathy Using Adaptive Optics Fundus Camera.

    Directory of Open Access Journals (Sweden)

    Mohamed Kamel Soliman

    Full Text Available To assess cone density as a marker of early signs of retinopathy in patients with type II diabetes mellitus.An adaptive optics (AO retinal camera (rtx1™; Imagine Eyes, Orsay, France was used to acquire images of parafoveal cones from patients with type II diabetes mellitus with or without retinopathy and from healthy controls with no known systemic or ocular disease. Cone mosaic was captured at 0° and 2°eccentricities along the horizontal and vertical meridians. The density of the parafoveal cones was calculated within 100×100-μm squares located at 500-μm from the foveal center along the orthogonal meridians. Manual corrections of the automated counting were then performed by 2 masked graders. Cone density measurements were evaluated with ANOVA that consisted of one between-subjects factor, stage of retinopathy and the within-subject factors. The ANOVA model included a complex covariance structure to account for correlations between the levels of the within-subject factors.Ten healthy participants (20 eyes and 25 patients (29 eyes with type II diabetes mellitus were recruited in the study. The mean (± standard deviation [SD] age of the healthy participants (Control group, patients with diabetes without retinopathy (No DR group, and patients with diabetic retinopathy (DR group was 55 ± 8, 53 ± 8, and 52 ± 9 years, respectively. The cone density was significantly lower in the moderate nonproliferative diabetic retinopathy (NPDR and severe NPDR/proliferative DR groups compared to the Control, No DR, and mild NPDR groups (P < 0.05. No correlation was found between cone density and the level of hemoglobin A1c (HbA1c or the duration of diabetes.The extent of photoreceptor loss on AO imaging may correlate positively with severity of DR in patients with type II diabetes mellitus. Photoreceptor loss may be more pronounced among patients with advanced stages of DR due to higher risk of macular edema and its sequelae.

  3. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  4. Preoperative staging of rectal cancer

    International Nuclear Information System (INIS)

    Schaefer, A.O.; Baumann, T.; Pache, G.; Langer, M.; Wiech, T.

    2007-01-01

    Accurate preoperative staging of rectal cancer is crucial for therapeutic decision making, as local tumor extent, nodal status, and patterns of metastatic spread are directly associated with different treatment strategies. Recently, treatment approaches have been widely standardized according to large studies and consensus guidelines. Introduced by Heald, total mesorectal excision (TME) is widely accepted as the surgical procedure of choice to remove the rectum together with its enveloping tissues and the mesorectal fascia. Neoadjuvant radiochemotherapy also plays a key role in the treatment of locally advanced stages, while the use of new drugs will lead to a further improvement in oncological outcome. Visualization of the circumferential resection margin is the hallmark of any preoperative imaging and a prerequisite for high-quality TME surgery. The aim of this article is to present an overview on current cross-sectional imaging with emphasis on magnetic resonance imaging. Future perspectives in rectal cancer imaging are addressed. (orig.)

  5. A fractal-based image encryption system

    KAUST Repository

    Abd-El-Hafiz, S. K.

    2014-12-01

    This study introduces a novel image encryption system based on diffusion and confusion processes in which the image information is hidden inside the complex details of fractal images. A simplified encryption technique is, first, presented using a single-fractal image and statistical analysis is performed. A general encryption system utilising multiple fractal images is, then, introduced to improve the performance and increase the encryption key up to hundreds of bits. This improvement is achieved through several parameters: feedback delay, multiplexing and independent horizontal or vertical shifts. The effect of each parameter is studied separately and, then, they are combined to illustrate their influence on the encryption quality. The encryption quality is evaluated using different analysis techniques such as correlation coefficients, differential attack measures, histogram distributions, key sensitivity analysis and the National Institute of Standards and Technology (NIST) statistical test suite. The obtained results show great potential compared to other techniques.

  6. MRI in staging of rectal carcinoma

    International Nuclear Information System (INIS)

    Gourtsoyianni, S.

    2012-01-01

    Full text: MRI of the rectum is performed for initial local staging of primary rectal cancer in order to identify locally advanced rectal cancers and for assessment of treatment response after completion of neoadjuvant therapy. Introduction of new generation MRI scanners with optimal phased array body coils, resulting in improved contrast and spatial resolution images due to better signal to noise ratio, have contributed to production of high resolution images in which visualization of anatomical details such as the mesorectal fascia and the bowel wall layers are feasible. Pre-operative MRI of the rectum using mainly high resolution T2 weighted sequences has gained significant accreditation, especially after the introduction of total mesorectal excision (TME) surgery and neoadjuvant therapy in the treatment regimen of rectal cancer. MR Imaging is so far the only method that can preoperatively identify patients most likely to benefit from neoadjuvant therapy as well as demonstrate high risk patients for local recurrence. Regarding N stage besides of mesorectal lymph nodes which are removed during TME, especially in case of low lying rectal cancers, MRI may provide information regarding external/internal iliac lymph node involvement. High resolution MRI images may demonstrate lymph nodes with a diameter down to 2 mm, however these are still characterized based on their morphological features. Patients identified at initial MRI staging as having locally advanced rectal cancer undergo neoadjuvant chemoradiation therapy (CRT) in order for their tumor to be downsized and downstaged, especially in low rectal cancers so that sphincter sparing surgery may be performed. In 15-30% of patients complete pathological response is achieved. Reimaging with MRI at 6 weeks post treatment is of great importance for assessing tumor response. Conventional MRI has a reported moderate accuracy for prediction of mesorectal fascia (MF) involvement after CRT therapy, mainly due to its

  7. COMPUTER AIDED DIAGNOSIS FOR DETECTION AND STAGE IDENTIFICATION OF CERVICAL CANCER BY USING PAP SMEAR SCREENING TEST IMAGES

    Directory of Open Access Journals (Sweden)

    S. Athinarayanan

    2016-05-01

    Full Text Available The majority of the women of the world were affected by the disease of cervical cancer. As a result of this disease, their death rate was increase as hasty level. Hence so many number of research people was focused this notion as their research interest and also they have done so many number of solutions for finding this cancer by using some image processing technique and achieved a good results only in advanced and high cost techniques of LBC, biopsy or Colposcopy test Images. Therefore the reason, the authors have chosen this problem and also did not only to find whether the patient is affected by a cancer or not. In addition to the patient was affected by this cancer means and also to identify which severity stage of this disease the patient could be live. Then this work has done in based on the images of low cost pap smear screening test by using various image processing techniques with the help of Computerized Image Processing Software Interactive Data Language (IDL-Image Processing Language. Thus the final reports would be very useful to the pathologists for further analysis.

  8. Simulation of an image network in a medical image information system

    International Nuclear Information System (INIS)

    Massar, A.D.A.; De Valk, J.P.J.; Reijns, G.L.; Bakker, A.R.

    1985-01-01

    The desirability of an integrated (digital) communication system for medical images is widely accepted. In the USA and in Europe several experimental projects are in progress to realize (a part of) such a system. Among these is the IMAGIS project in the Netherlands. From the conclusions of the preliminary studies performed, some requirements can be formulated such a system should meet in order to be accepted by its users. For example, the storage resolution of the images should match the maximum resolution of the presently acquired digital images. This determines the amount of data and therefore the storage requirements. Further, the desired images should be there when needed. This time constraint determines the speed requirements to be imposed on the system. As compared to current standards, very large storage capacities and very fast communication media are needed to meet these requirements. By employing cacheing techniques and suitable data compression schemes for the storage and by carefully choosing the network protocols, bare capacity demands can be alleviated. A communication network is needed to make the imaging system available over a larger area. As the network is very likely to become a major bottleneck for system performance, effects of variation of various attributes have to be carefully studied and analysed. After interesting results had been obtained (although preliminary) using a simulation model for a layered storage structure, it was decided to apply simulation also to this problem. Effects of network topology, access protocols and buffering strategies will be tested. Changes in performance resulting from changes in various network parameters will be studied. Results of this study at its present state are presented

  9. Millimeter-wave Imaging Systems with Aperture Synthesis Techniques

    DEFF Research Database (Denmark)

    Löffler, Torsten; Krozer, Viktor; Zhurbenko, Vitaliy

    2010-01-01

    The paper describes development of a millimetre-wave imaging system using multi-element aperture filling techniques [1]. Such imaging systems are increasingly demonstrated for security applications and in particular standoff imaging of persons and bonding flaw and defect detection [2]. The major ...

  10. Coupling effect and control strategies of the maglev dual-stage inertially stabilization system based on frequency-domain analysis.

    Science.gov (United States)

    Lin, Zhuchong; Liu, Kun; Zhang, Li; Zeng, Delin

    2016-09-01

    Maglev dual-stage inertially stabilization (MDIS) system is a newly proposed system which combines a conventional two-axis gimbal assembly and a 5-DOF (degree of freedom) magnetic bearing with vernier tilting capacity to perform dual-stage stabilization for the LOS of the suspended optical instrument. Compared with traditional dual-stage system, maglev dual-stage system exhibits different characteristics due to the negative position stiffness of the magnetic forces, which introduces additional coupling in the dual stage control system. In this paper, the coupling effect on the system performance is addressed based on frequency-domain analysis, including disturbance rejection, fine stage saturation and coarse stage structural resonance suppression. The difference between various control strategies is also discussed, including pile-up(PU), stabilize-follow (SF) and stabilize-compensate (SC). A number of principles for the design of a maglev dual stage system are proposed. A general process is also suggested, which leads to a cost-effective design striking a balance between high performance and complexity. At last, a simulation example is presented to illustrate the arguments in the paper. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Production system and harvesting stage influence on nitrate content and quality of butterhead lettuce

    Directory of Open Access Journals (Sweden)

    Siti Fairuz Yosoff

    2015-01-01

    Full Text Available Leafy vegetables such as lettuce grown under different production systems may accumulate different concentrations of nitrate which may reach to the levels potentially toxic to humans. Moreover, nitrate accumulation varies in various plant parts and physiological age of the plant. Therefore, to determine the effect of production system and harvesting stage on nitrate accumulation and quality of butterhead lettuce, a study was conducted considering two lettuce production systems namely hydroponic and organic, and four different harvesting stages such as 35, 38, 41 and 44 days after transplanting (DAT. The experimental design was complete randomized design (CRD with four replications. Hydroponic and organic systems performed similar in terms of yield, quality and nitrate content of butterhead lettuce. Delaying harvesting can not only increase yield but also can minimize nitrate accumulation and health hazard risk as well. Delay in harvesting stage may result in quality deterioration of lettuce and increased production cost. Thus, a compromise is necessary to consider 41 DAT as the optimum stage to harvest butterhead lettuce with significantly higher reduction of nitrate content in both outer adult leaf blades and young leaves of hydroponic lettuce. Fresh weight, firmness and color of butterhead lettuce at this stage were still acceptable.

  12. Seventh edition (2010) of the AJCC/UICC staging system for gastric adenocarcinoma: is there room for improvement?

    Science.gov (United States)

    Patel, Manali I; Rhoads, Kim F; Ma, Yifei; Ford, James M; Visser, Brendan C; Kunz, Pamela L; Fisher, George A; Chang, Daniel T; Koong, Albert; Norton, Jeffrey A; Poultsides, George A

    2013-05-01

    The gastric cancer AJCC/UICC staging system recently underwent significant revisions, but studies on Asian patients have reported a lack of adequate discrimination between various consecutive stages. We sought to validate the new system on a U.S. population database. California Cancer Registry data linked to the Office of Statewide Health Planning and Development discharge abstracts were used to identify patients with gastric adenocarcinoma (esophagogastric junction and gastric cardia tumors excluded) who underwent curative-intent surgical resection in California from 2002 to 2006. AJCC/UICC stage was recalculated based on the latest seventh edition. Overall survival probabilities were calculated using the Kaplan-Meier method. Of 1905 patients analyzed, 54 % were males with a median age of 70 years. Median number of pathologically examined lymph nodes was 12 (range, 1-90); 40 % of patients received adjuvant chemotherapy, and 31 % received adjuvant radiotherapy. The seventh edition AJCC/UICC system did not distinguish outcome adequately between stages IB and IIA (P = 0.40), or IIB and IIIA (P = 0.34). By merging stage II into 1 category and moving T2N1 to stage IB and T2N2, T1N3 to stage IIIA, we propose a new grouping system with improved discriminatory ability In this first study validating the new seventh edition AJCC/UICC staging system for gastric cancer on a U.S. population with a relatively limited number of lymph nodes examined, we found stages IB and IIA, as well as IIB and IIIA to perform similarly. We propose a revised stage grouping for the AJCC/UICC staging system that better discriminates between outcomes.

  13. A novel approach to 32-channel peripheral nervous system myelin imaging in vivo, with single axon resolution.

    Science.gov (United States)

    Grochmal, Joey; Teo, Wulin; Gambhir, Hardeep; Kumar, Ranjan; Stratton, Jo Anne; Dhaliwal, Raveena; Brideau, Craig; Biernaskie, Jeff; Stys, Peter K; Midha, Rajiv

    2018-01-19

    OBJECTIVE Intravital spectral imaging of the large, deeply situated nerves in the rat peripheral nervous system (PNS) has not been well described. Here, the authors have developed a highly stable platform for performing imaging of the tibial nerve in live rodents, thus allowing the capture of high-resolution, high-magnification spectral images requiring long acquisition times. By further exploiting the qualities of the topically applied myelin dye Nile red, this technique is capable of visualizing the detailed microenvironment of peripheral nerve demyelination injury and recovery, while allowing us to obtain images of exogenous Schwann cell myelination in a living animal. METHODS The authors caused doxorubicin-induced focal demyelination in the tibial nerves of 25 Thy-1 GFP rats, of which 2 subsets (n = 10 each) received either BFP-labeled SKP-SCs or SCs to the zone of injury. Prior to acquiring images of myelin recovery in these nerves, a tibial nerve window was constructed using a silicone hemitube, a fast drying silicone polymer, and a small coverslip. This construct was then affixed to a 3D-printed nerve stage, which in turn was affixed to an external fixation/microscope stage device. Myelin visualization was facilitated by the topical application of Nile red. RESULTS The authors reliably demonstrated intravital peripheral nerve myelin imaging with micron-level resolution and magnification, and minimal movement artifact. The detailed microenvironment of nerve remyelination can be vividly observed, while exogenously applied Schwann cells and skin-derived precursor Schwann cells can be seen myelinating axons. CONCLUSIONS Topically applied Nile red enables intravital study of myelin in the living rat PNS. Furthermore, the use of a tibial nerve window facilitates stable intravital peripheral nerve imaging, making possible high-definition spectral imaging with long acquisition times.

  14. Embryonic staging using a 3D virtual reality system

    NARCIS (Netherlands)

    C.M. Verwoerd-Dikkeboom (Christine); A.H.J. Koning (Anton); P.J. van der Spek (Peter); N. Exalto (Niek); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractBACKGROUND: The aim of this study was to demonstrate that Carnegie Stages could be assigned to embryos visualized with a 3D virtual reality system. METHODS: We analysed 48 3D ultrasound scans of 19 IVF/ICSI pregnancies at 7-10 weeks' gestation. These datasets were visualized as 3D

  15. Micro-computed tomography newly developed for in vivo small animal imaging

    International Nuclear Information System (INIS)

    Arai, Yoshinori; Ninomiya, Tadashi; Kato, Takafumi; Masuda, Yuji

    2005-01-01

    The aim of this paper is to report a newly developed micro-computed tomography system for in vivo use. The system was composed of a micro-focus X-ray tube and an image intensifier (I.I.), both of which rotated around the object stage. A guinea pig and a rat were examined. The anesthetized animal was set on the secure object stage. Images of the head of the guinea pig and the tibia knee joint of the rat were taken. In addition, an image of the rat's tail was taken. The reconstruction and the image viewing were carried out using I-View software. The voxel matrix was 512 x 512 x 384. The voxel sizes ranged from 10 x 10 x 10 μm to 100 x 100 x 100 μm. The exposure time was 17 s, and the reconstruction time was 150 s. The head of the guinea pig and the tibia/knee joint of the rat were observed clearly under 100-μm and 30μm voxels, respectively. The trabecular bone of the tail was also observed clearly under a 10 μm voxel. The newly developed micro-computed tomography system makes it possible to obtain images of anesthetized animals set on a secure object stage. Clear bone images of the small animals could be obtained within a short time. (author)

  16. System for imaging plutonium through heavy shielding

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Cannon, T.M.; Fenimore, E.E.; Moss, C.E.; Nixon, K.V.

    1984-04-01

    A single pinhole can be used to image strong self-luminescent gamma-ray sources such as plutonium on gamma scintillation (Anger) cameras. However, if the source is weak or heavily shielded, a poor signal to noise ratio can prevent acquisition of the image. An imaging system designed and built at Los Alamos National Laboratory uses a coded aperture to image heavily shielded sources. The paper summarizes the mathematical techniques, based on the Fast Delta Hadamard transform, used to decode raw images. Practical design considerations such as the phase of the uniformly redundant aperture and the encoded image sampling are discussed. The imaging system consists of a custom designed m-sequence coded aperture, a Picker International Corporation gamma scintillation camera, a LeCroy 3500 data acquisition system, and custom imaging software. The paper considers two sources - 1.5 mCi 57 Co unshielded at a distance of 27 m and 220 g of bulk plutonium (11.8% 240 Pu) with 0.3 cm lead, 2.5 cm steel, and 10 cm of dense plastic material at a distance of 77.5 cm. Results show that the location and geometry of a source hidden in a large sealed package can be determined without having to open the package. 6 references, 4 figures

  17. Two-stage commercial evaluation of engineering systems production projects for high-rise buildings

    Science.gov (United States)

    Bril, Aleksander; Kalinina, Olga; Levina, Anastasia

    2018-03-01

    The paper is devoted to the current and debatable problem of methodology of choosing the effective innovative enterprises for venture financing. A two-stage system of commercial innovation evaluation based on the UNIDO methodology is proposed. Engineering systems account for 25 to 40% of the cost of high-rise residential buildings. This proportion increases with the use of new construction technologies. Analysis of the construction market in Russia showed that the production of internal engineering systems elements based on innovative technologies has a growth trend. The production of simple elements is organized in small enterprises on the basis of new technologies. The most attractive for development is the use of venture financing of small innovative business. To improve the efficiency of these operations, the paper proposes a methodology for a two-stage evaluation of small business development projects. A two-stage system of commercial evaluation of innovative projects allows creating an information base for informed and coordinated decision-making on venture financing of enterprises that produce engineering systems elements for the construction business.

  18. Two-stage commercial evaluation of engineering systems production projects for high-rise buildings

    Directory of Open Access Journals (Sweden)

    Bril Aleksander

    2018-01-01

    Full Text Available The paper is devoted to the current and debatable problem of methodology of choosing the effective innovative enterprises for venture financing. A two-stage system of commercial innovation evaluation based on the UNIDO methodology is proposed. Engineering systems account for 25 to 40% of the cost of high-rise residential buildings. This proportion increases with the use of new construction technologies. Analysis of the construction market in Russia showed that the production of internal engineering systems elements based on innovative technologies has a growth trend. The production of simple elements is organized in small enterprises on the basis of new technologies. The most attractive for development is the use of venture financing of small innovative business. To improve the efficiency of these operations, the paper proposes a methodology for a two-stage evaluation of small business development projects. A two-stage system of commercial evaluation of innovative projects allows creating an information base for informed and coordinated decision-making on venture financing of enterprises that produce engineering systems elements for the construction business.

  19. Prognostic value and molecular correlates of a CT image-based quantitative pleural contact index in early stage NSCLC

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juheon; Cui, Yi; Li, Bailiang; Wu, Jia; Gensheimer, Michael F. [Stanford University School of Medicine, Department of Radiation Oncology, Stanford, CA (United States); Sun, Xiaoli [First Affiliated Hospital of Zhejiang University, Radiotherapy Department, Hangzhou, Zhejiang (China); Li, Dengwang [Stanford University School of Medicine, Department of Radiation Oncology, Stanford, CA (United States); Shandong Normal University, Shandong Province Key Laboratory of Medical Physics and Image Processing Technology, Institute of Biomedical Sciences, School of Physics and Electronics, Jinan Shi (China); Loo, Billy W.; Li, Ruijiang [Stanford University School of Medicine, Department of Radiation Oncology, Stanford, CA (United States); Stanford University School of Medicine, Stanford Cancer Institute, Stanford, CA (United States); Diehn, Maximilian [Stanford University School of Medicine, Department of Radiation Oncology, Stanford, CA (United States); Stanford University School of Medicine, Stanford Cancer Institute, Stanford, CA (United States); Stanford University School of Medicine, Institute for Stem Cell Biology and Regenerative Medicine, Stanford, CA (United States)

    2018-02-15

    To evaluate the prognostic value and molecular basis of a CT-derived pleural contact index (PCI) in early stage non-small cell lung cancer (NSCLC). We retrospectively analysed seven NSCLC cohorts. A quantitative PCI was defined on CT as the length of tumour-pleura interface normalised by tumour diameter. We evaluated the prognostic value of PCI in a discovery cohort (n = 117) and tested in an external cohort (n = 88) of stage I NSCLC. Additionally, we identified the molecular correlates and built a gene expression-based surrogate of PCI using another cohort of 89 patients. To further evaluate the prognostic relevance, we used four datasets totalling 775 stage I patients with publically available gene expression data and linked survival information. At a cutoff of 0.8, PCI stratified patients for overall survival in both imaging cohorts (log-rank p = 0.0076, 0.0304). Extracellular matrix (ECM) remodelling was enriched among genes associated with PCI (p = 0.0003). The genomic surrogate of PCI remained an independent predictor of overall survival in the gene expression cohorts (hazard ratio: 1.46, p = 0.0007) adjusting for age, gender, and tumour stage. CT-derived pleural contact index is associated with ECM remodelling and may serve as a noninvasive prognostic marker in early stage NSCLC. (orig.)

  20. MIDAS - ESO's new image processing system

    Science.gov (United States)

    Banse, K.; Crane, P.; Grosbol, P.; Middleburg, F.; Ounnas, C.; Ponz, D.; Waldthausen, H.

    1983-03-01

    The Munich Image Data Analysis System (MIDAS) is an image processing system whose heart is a pair of VAX 11/780 computers linked together via DECnet. One of these computers, VAX-A, is equipped with 3.5 Mbytes of memory, 1.2 Gbytes of disk storage, and two tape drives with 800/1600 bpi density. The other computer, VAX-B, has 4.0 Mbytes of memory, 688 Mbytes of disk storage, and one tape drive with 1600/6250 bpi density. MIDAS is a command-driven system geared toward the interactive user. The type and number of parameters in a command depends on the unique parameter invoked. MIDAS is a highly modular system that provides building blocks for the undertaking of more sophisticated applications. Presently, 175 commands are available. These include the modification of the color-lookup table interactively, to enhance various image features, and the interactive extraction of subimages.

  1. Design of CMOS imaging system based on FPGA

    Science.gov (United States)

    Hu, Bo; Chen, Xiaolai

    2017-10-01

    In order to meet the needs of engineering applications for high dynamic range CMOS camera under the rolling shutter mode, a complete imaging system is designed based on the CMOS imaging sensor NSC1105. The paper decides CMOS+ADC+FPGA+Camera Link as processing architecture and introduces the design and implementation of the hardware system. As for camera software system, which consists of CMOS timing drive module, image acquisition module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The ISE 14.6 emulator ISim is used in the simulation of signals. The imaging experimental results show that the system exhibits a 1280*1024 pixel resolution, has a frame frequency of 25 fps and a dynamic range more than 120dB. The imaging quality of the system satisfies the requirement of the index.

  2. Focus on Merkel cell carcinoma: diagnosis and staging

    International Nuclear Information System (INIS)

    Grandhaye, Marion; Teixeira, Pedro Gondim; Blum, Alain; Henrot, Philippe; Morel, Olivier; Sirveaux, Francois; Verhaeghe, Jean-Luc

    2015-01-01

    Merkel cell carcinoma is a rare lymphophilic skin tumor of neuroendocrine origin with the potential for rapid progression. Small, localized lesions are diagnosed and treated clinically, but advanced tumors often undergo imaging evaluation. Due to its rarity, radiologists are unaware of evocative imaging features and usually do not consider Merkel cell carcinoma in the differential diagnosis of soft tissue tumors. Appropriate staging is important to determine appropriate treatment and has an impact on patient prognosis. Multimodality imaging is usually needed, and there is no consensus on the optimal imaging strategy. The purpose of this article is to review various aspects of Merkel cell carcinoma imaging and look in detail at how optimal multimodality staging should be carried out. (orig.)

  3. Focus on Merkel cell carcinoma: diagnosis and staging

    Energy Technology Data Exchange (ETDEWEB)

    Grandhaye, Marion; Teixeira, Pedro Gondim; Blum, Alain [Imagerie Guilloz CHU de Nancy Hopital Central, Nancy (France); Henrot, Philippe [Service de Radiologie Institut de Cancerologie de Lorraine, Vandoeuvre les Nancy (France); Morel, Olivier [Medecine Nucleaire CHU Nancy Hopital Brabois, Vancoeuvre les Nancy (France); Sirveaux, Francois [Service de Chirurgie Centre chirurgical Emile Galle, Nancy (France); Verhaeghe, Jean-Luc [Service de Chirurgie Institut de Cancerologie de Lorraine, Vandoeuvre les Nancy (France)

    2015-06-01

    Merkel cell carcinoma is a rare lymphophilic skin tumor of neuroendocrine origin with the potential for rapid progression. Small, localized lesions are diagnosed and treated clinically, but advanced tumors often undergo imaging evaluation. Due to its rarity, radiologists are unaware of evocative imaging features and usually do not consider Merkel cell carcinoma in the differential diagnosis of soft tissue tumors. Appropriate staging is important to determine appropriate treatment and has an impact on patient prognosis. Multimodality imaging is usually needed, and there is no consensus on the optimal imaging strategy. The purpose of this article is to review various aspects of Merkel cell carcinoma imaging and look in detail at how optimal multimodality staging should be carried out. (orig.)

  4. White matter abnormalities in treatment-naive adolescents at the earliest stages of Anorexia Nervosa: A diffusion tensor imaging study.

    Science.gov (United States)

    Gaudio, Santino; Quattrocchi, Carlo Cosimo; Piervincenzi, Claudia; Zobel, Bruno Beomonte; Montecchi, Francesca Romana; Dakanalis, Antonios; Riva, Giuseppe; Carducci, Filippo

    2017-08-30

    Few studies have examined white matter (WM) integrity in long-lasting Anorexia Nervosa (AN) patients using Diffusion Tensor Imaging (DTI). In this paper, we investigated WM integrity at the earliest stages of AN (i.e. less than 6 months duration). Fourteen treatment-naive female adolescents with AN restrictive type (AN-r) in its earliest stages and 15 age-matched healthy females received brain MRI. Fractional Anisotropy (FA), Axial Diffusivity (AD), Radial diffusivity (RD), and Mean Diffusivity (MD) maps were computed from DTI data using Tract-Based Spatial Statistics analysis. AN-r patients showed FA decreases compared to controls (p FWE < 0.05) mainly in left anterior and superior corona radiata and left superior longitudinal fasciculus. AN-r patients also showed decreased AD in superior longitudinal fasciculus bilaterally and left superior and anterior corona radiata, (p FWE < 0.05). No significant differences were found in RD and MD values between the two groups. FA and AD integrity appears to be specifically affected at the earliest stages of AN. Alterations in the microstructural properties of the above mentioned tracts, also involved in cognitive control and visual perception and processing, may be early mechanisms of vulnerability/resilience of WM in AN and sustain the key symptoms of AN, such as impaired cognitive flexibility and body image distortion. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  5. Lossy image compression for digital medical imaging systems

    Science.gov (United States)

    Wilhelm, Paul S.; Haynor, David R.; Kim, Yongmin; Nelson, Alan C.; Riskin, Eve A.

    1990-07-01

    Image compression at rates of 10:1 or greater could make PACS much more responsive and economically attractive. This paper describes a protocol for subjective and objective evaluation of the fidelity of compressed/decompressed images to the originals and presents the results ofits application to four representative and promising compression methods. The methods examined are predictive pruned tree-structured vector quantization, fractal compression, the discrete cosine transform with equal weighting of block bit allocation, and the discrete cosine transform with human visual system weighting of block bit allocation. Vector quantization is theoretically capable of producing the best compressed images, but has proven to be difficult to effectively implement. It has the advantage that it can reconstruct images quickly through a simple lookup table. Disadvantages are that codebook training is required, the method is computationally intensive, and achieving the optimum performance would require prohibitively long vector dimensions. Fractal compression is a relatively new compression technique, but has produced satisfactory results while being computationally simple. It is fast at both image compression and image reconstruction. Discrete cosine iransform techniques reproduce images well, but have traditionally been hampered by the need for intensive computing to compress and decompress images. A protocol was developed for side-by-side observer comparison of reconstructed images with originals. Three 1024 X 1024 CR (Computed Radiography) images and two 512 X 512 X-ray CT images were viewed at six bit rates (0.2, 0.4, 0.6, 0.9, 1.2, and 1.5 bpp for CR, and 1.0, 1.3, 1.6, 1.9, 2.2, 2.5 bpp for X-ray CT) by nine radiologists at the University of Washington Medical Center. The CR images were viewed on a Pixar II Megascan (2560 X 2048) monitor and the CT images on a Sony (1280 X 1024) monitor. The radiologists' subjective evaluations of image fidelity were compared to

  6. Validation of the Mayo Clinic Staging System in Determining Prognoses of Patients With Perihilar Cholangiocarcinoma

    NARCIS (Netherlands)

    Coelen, Robert J. S.; Gaspersz, Marcia P.; Labeur, Tim A.; van Vugt, Jeroen L. A.; van Dieren, Susan; Willemssen, François E. J. A.; Nio, Chung Y.; Ijzermans, Jan N. M.; Klümpen, Heinz-Josef; Groot Koerkamp, Bas; van Gulik, Thomas M.

    2017-01-01

    BACKGROUND & AIMS: Most systems for staging perihilar cholangiocarcinoma (PHC) have been developed for the minority of patients with resectable disease. The recently developed Mayo Clinic system for staging PHC requires only clinical and radiologic variables, but has not yet been validated. We

  7. Image Compression Based On Wavelet, Polynomial and Quadtree

    Directory of Open Access Journals (Sweden)

    Bushra A. SULTAN

    2011-01-01

    Full Text Available In this paper a simple and fast image compression scheme is proposed, it is based on using wavelet transform to decompose the image signal and then using polynomial approximation to prune the smoothing component of the image band. The architect of proposed coding scheme is high synthetic where the error produced due to polynomial approximation in addition to the detail sub-band data are coded using both quantization and Quadtree spatial coding. As a last stage of the encoding process shift encoding is used as a simple and efficient entropy encoder to compress the outcomes of the previous stage.The test results indicate that the proposed system can produce a promising compression performance while preserving the image quality level.

  8. Image BOSS: a biomedical object storage system

    Science.gov (United States)

    Stacy, Mahlon C.; Augustine, Kurt E.; Robb, Richard A.

    1997-05-01

    Researchers using biomedical images have data management needs which are oriented perpendicular to clinical PACS. The image BOSS system is designed to permit researchers to organize and select images based on research topic, image metadata, and a thumbnail of the image. Image information is captured from existing images in a Unix based filesystem, stored in an object oriented database, and presented to the user in a familiar laboratory notebook metaphor. In addition, the ImageBOSS is designed to provide an extensible infrastructure for future content-based queries directly on the images.

  9. An XCT image database system

    International Nuclear Information System (INIS)

    Komori, Masaru; Minato, Kotaro; Koide, Harutoshi; Hirakawa, Akina; Nakano, Yoshihisa; Itoh, Harumi; Torizuka, Kanji; Yamasaki, Tetsuo; Kuwahara, Michiyoshi.

    1984-01-01

    In this paper, an expansion of X-ray CT (XCT) examination history database to XCT image database is discussed. The XCT examination history database has been constructed and used for daily examination and investigation in our hospital. This database consists of alpha-numeric information (locations, diagnosis and so on) of more than 15,000 cases, and for some of them, we add tree structured image data which has a flexibility for various types of image data. This database system is written by MUMPS database manipulation language. (author)

  10. Using a web-based image quality assurance reporting system to improve image quality.

    Science.gov (United States)

    Czuczman, Gregory J; Pomerantz, Stuart R; Alkasab, Tarik K; Huang, Ambrose J

    2013-08-01

    The purpose of this study is to show the impact of a web-based image quality assurance reporting system on the rates of three common image quality errors at our institution. A web-based image quality assurance reporting system was developed and used beginning in April 2009. Image quality endpoints were assessed immediately before deployment (period 1), approximately 18 months after deployment of a prototype reporting system (period 2), and approximately 12 months after deployment of a subsequent upgraded department-wide reporting system (period 3). A total of 3067 axillary shoulder radiographs were reviewed for correct orientation, 355 shoulder CT scans were reviewed for correct reformatting of coronal and sagittal images, and 346 sacral MRI scans were reviewed for correct acquisition plane of axial images. Error rates for each review period were calculated and compared using the Fisher exact test. Error rates of axillary shoulder radiograph orientation were 35.9%, 7.2%, and 10.0%, respectively, for the three review periods. The decrease in error rate between periods 1 and 2 was statistically significant (p < 0.0001). Error rates of shoulder CT reformats were 9.8%, 2.7%, and 5.8%, respectively, for the three review periods. The decrease in error rate between periods 1 and 2 was statistically significant (p = 0.03). Error rates for sacral MRI axial sequences were 96.5%, 32.5%, and 3.4%, respectively, for the three review periods. The decrease in error rates between periods 1 and 2 and between periods 2 and 3 was statistically significant (p < 0.0001). A web-based system for reporting image quality errors may be effective for improving image quality.

  11. Staging for vulvar cancer.

    Science.gov (United States)

    Hacker, Neville F; Barlow, Ellen L

    2015-08-01

    Vulvar cancer has been staged by the International Federation of Gynaecology and Obstetrics (FIGO) since 1969, and the original staging system was based on clinical findings only. This system provided a very good spread of prognostic groupings. Because vulvar cancer is virtually always treated surgically, the status of the lymph nodes is the most important prognostic factor and this can only be determined with certainty by histological examination of resected lymph nodes, FIGO introduced a surgical staging system in 1988. This was modified in 1994 to include a category of microinvasive vulvar cancer (stage IA), because such patients have virtually no risk of lymph node metastases. This system did not give a reasonably even spread of prognostic groupings. In addition, patients with stage III disease were shown to be a heterogeneous group prognostically, and the number of positive nodes and the morphology of those nodes were not taken into account. A new surgical staging system for vulvar cancer was introduced by FIGO in 2009. Initial retrospective analyses have suggested that this new staging system has overcome the major deficiencies in the 1994 system. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  12. Development of an image intensifier-TV digital imaging system with a multiple-slit scanning x-ray beam

    International Nuclear Information System (INIS)

    Kume, Y.; Doi, K.

    1986-01-01

    The authors are developing a new digital x-ray imaging system employing a multiple-slit assembly (MSA) and an image intensifier (II)-TV digital system. The final image consisting of primary radiation is digitally reconstructed from multiple slit images obtained with the MSA. This system can significantly reduce the scattered radiation from an object and the veiling glare from II-TV system. The quality of the reconstructed image is related to many parameters, such as slit width, the number of image frames, and the image reconstruction algorithm. They present the effect of these various parameters on basic imaging properties and the practicability of the method in comparison with conventional wide beam imaging

  13. Image processing system for flow pattern measurements

    International Nuclear Information System (INIS)

    Ushijima, Satoru; Miyanaga, Yoichi; Takeda, Hirofumi

    1989-01-01

    This paper describes the development and application of an image processing system for measurements of flow patterns occuring in natural circulation water flows. In this method, the motions of particles scattered in the flow are visualized by a laser light slit and they are recorded on normal video tapes. These image data are converted to digital data with an image processor and then transfered to a large computer. The center points and pathlines of the particle images are numerically analized, and velocity vectors are obtained with these results. In this image processing system, velocity vectors in a vertical plane are measured simultaneously, so that the two dimensional behaviors of various eddies, with low velocity and complicated flow patterns usually observed in natural circulation flows, can be determined almost quantitatively. The measured flow patterns, which were obtained from natural circulation flow experiments, agreed with photographs of the particle movements, and the validity of this measuring system was confirmed in this study. (author)

  14. Extraction of latent images from printed media

    Science.gov (United States)

    Sergeyev, Vladislav; Fedoseev, Victor

    2015-12-01

    In this paper we propose an automatic technology for extraction of latent images from printed media such as documents, banknotes, financial securities, etc. This technology includes image processing by adaptively constructed Gabor filter bank for obtaining feature images, as well as subsequent stages of feature selection, grouping and multicomponent segmentation. The main advantage of the proposed technique is versatility: it allows to extract latent images made by different texture variations. Experimental results showing performance of the method over another known system for latent image extraction are given.

  15. Under sodium ultrasonic imaging system for PFBR

    International Nuclear Information System (INIS)

    Patankar, V.H.; Lalwani, S.K.; Agashe, A.A.

    2014-01-01

    Under Sodium UltraSonic Scanner (USUSS) has been developed to detect the growth and protrusion of fuel sub-assemblies of PFBR, submerged in liquid sodium by using the ultrasonic imaging technique during reactor shut-down when liquid sodium is at 180 ℃. The imaging is carried out prior to every Fuel handling operation. Electronics Division, BARC has designed and developed an 8-Channel Ultrasonic Imaging System (UIS) which consists of 4 downward viewing and 4 side viewing ultrasonic transducers alongwith pulser-receiver, signal processing electronics hardware and software. An automated mechanical scanner developed by IGCAR houses sodium immersible transducers to image the fuel sub assemblies. The system has been successfully tested with dummy protruding and grown FSAs, submerged under liquid sodium. Such ultrasonic imaging systems are not available to India from international market. The USUSS developed indigenously has all the features available in similar systems developed by other countries. After every imaging campaign, the mechanical scanner containing ultrasonic transducers is stored in the Argon filled storage-pit. Before every campaign of USUSS, it is necessary to check the healthiness of the sodium immersible and contaminated ultrasonic transducers, as the under-sodium scanner is decontaminated once in five years. For this purpose, a novel Non Contact Ultrasonic Inspection System (NCUIS) has been designed and developed by Electronics Division, BARC to check the functionality of the high-temperature and contaminated transducers of USUSS, using air-coupled ultrasonic technique. (author)

  16. Development and validation of a preoperative prediction model for colorectal cancer T-staging based on MDCT images and clinical information.

    Science.gov (United States)

    Sa, Sha; Li, Jing; Li, Xiaodong; Li, Yongrui; Liu, Xiaoming; Wang, Defeng; Zhang, Huimao; Fu, Yu

    2017-08-15

    This study aimed to establish and evaluate the efficacy of a prediction model for colorectal cancer T-staging. T-staging was positively correlated with the level of carcinoembryonic antigen (CEA), expression of carbohydrate antigen 19-9 (CA19-9), wall deformity, blurred outer edges, fat infiltration, infiltration into the surrounding tissue, tumor size and wall thickness. Age, location, enhancement rate and enhancement homogeneity were negatively correlated with T-staging. The predictive results of the model were consistent with the pathological gold standard, and the kappa value was 0.805. The total accuracy of staging improved from 51.04% to 86.98% with the proposed model. The clinical, imaging and pathological data of 611 patients with colorectal cancer (419 patients in the training group and 192 patients in the validation group) were collected. A spearman correlation analysis was used to validate the relationship among these factors and pathological T-staging. A prediction model was trained with the random forest algorithm. T staging of the patients in the validation group was predicted by both prediction model and traditional method. The consistency, accuracy, sensitivity, specificity and area under the curve (AUC) were used to compare the efficacy of the two methods. The newly established comprehensive model can improve the predictive efficiency of preoperative colorectal cancer T-staging.

  17. Application of two-stage biofilter system for the removal of odorous compounds.

    Science.gov (United States)

    Jeong, Gwi-Taek; Park, Don-Hee; Lee, Gwang-Yeon; Cha, Jin-Myeong

    2006-01-01

    Biofiltration is a biological process which is considered to be one of the more successful examples of biotechnological applications to environmental engineering, and is most commonly used in the removal of odoriferous compounds. In this study, we have attempted to assess the efficiency with which both single and complex odoriferous compounds could be removed, using one- or two-stage biofiltration systems. The tested single odor gases, limonene, alpha-pinene, and iso-butyl alcohol, were separately evaluated in the biofilters. Both limonene and alpha-pinene were removed by 90% or more EC (elimination capacity), 364 g/m3/h and 321 g/m3/h, respectively, at an input concentration of 50 ppm and a retention time of 30 s. The iso-butyl alcohol was maintained with an effective removal yield of more than 90% (EC 375 g/m3/h) at an input concentration of 100 ppm. The complex gas removal scheme was applied with a 200 ppm inlet concentration of ethanol, 70 ppm of acetaldehyde, and 70 ppm of toluene with residence time of 45 s in a one- or two-stage biofiltration system. The removal yield of toluene was determined to be lower than that of the other gases in the one-stage biofilter. Otherwise, the complex gases were sufficiently eliminated by the two-stage biofiltration system.

  18. A new remote-imaging diagnosis system at Komazawa University

    International Nuclear Information System (INIS)

    Shimada, Morio; Kohda, Eiichi; Yoshikawa, Kohki

    2007-01-01

    We developed a remote-imaging diagnosis system that links the highly experienced radiologists at Komazawa University with Fuji Electric Hospital, where no such radiologists are present. MRI or CT images from Fuji Electric hospital are transmitted to Komazawa University via private line (INS64). The radiologists at Komazawa University then read the MRI or CT images, and relay the results to Fuji Electric Hospital. We describe the advantages and disadvantages of this system. MRI or CT imaging data from 80 cases were used. The data were stored in the imaging system server at Fuji Electric Hospital and were evaluated by experienced radiologists at Komazawa University. The images were sent one by one to the diagnostic support system server at Komazawa University through the private INS64 line. We examined transmission time per case and the security of transmission. Transmission of MRI or CT images from the 80 cases required a mean duration of 63 minutes 30 seconds per image. The quality of all images was highly satisfactory. In addition, there was no evidence of weaknesses in security. A physician at Fuji Electric Hospital was able to readily explain to the patient the results of the images by referring to the findings written by a radiologist at Komazawa University. We were able to transmit MRI or CT images by using this system safely and readily. The primary disadvantage of this system was the slow transmission speed. This will be improved by upgrading to an optical fibers. (author)

  19. Spleen dynamic contrast-enhanced magnetic resonance imaging as a new method for staging liver fibrosis in a piglet model.

    Directory of Open Access Journals (Sweden)

    Li Zhou

    Full Text Available OBJECTIVE: To explore spleen hemodynamic alteration in liver fibrosis with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI, and to determine how to stage liver fibrosis with spleen DCE-MRI parameters. MATERIALS AND METHODS: Sixteen piglets were prospectively used to model liver fibrosis staged by liver biopsy, and underwent spleen DCE-MRI on 0, 5th, 9th, 16th and 21st weekend after modeling this disease. DCE-MRI parameters including time to peak (TTP, positive enhancement integral (PEI, maximum slope of increase (MSI and maximum slope of decrease (MSD of spleen were measured, and statistically analyzed to stage this disease. RESULTS: Spearman's rank correlation tests showed that TTP tended to increase with increasing stages of liver fibrosis (r = 0.647, P0.05, and decreased from stage 2 to 4 (P0.05. Mann-Whitney tests demonstrated that TTP and PEI could classify fibrosis between stage 0 and 1-4, between 0-1 and 2-4, between 0-2 and 3-4, or between 0-3 and 4 (all P<0.01. MSD could discriminate between 0-2 and 3-4 (P = 0.006, or between 0-3 and 4 (P = 0.012. MSI could not differentiate between any two stages. Receiver operating characteristic analysis illustrated that area under receiver operating characteristic curve (AUC of TTP was larger than of PEI for classifying stage ≥1 and ≥2 (AUC = 0.851 and 0.783, respectively. PEI could best classify stage ≥3 and 4 (AUC = 0.903 and 0.96, respectively. CONCLUSION: Spleen DCE-MRI has potential to monitor spleen hemodynamic alteration and classify liver fibrosis stages.

  20. Cerebral blood flow imaging in staging of dementia of Alzheimer type. A study using statistical parametric mapping (SPM)

    Energy Technology Data Exchange (ETDEWEB)

    Kawahata, Nobuya; Daitoh, Nobuyuki; Gotoh, Chiharu; Yokoyama, Sakura [Narita Memorial Hospital, Toyohashi, Aichi (Japan)

    2001-10-01

    One hundred twenty-two patients with dementia of Alzheimer type (DAT) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All fulfilled the NINCDS-ADRDA diagnostic criteria for probable Alzheimer's disease. Patients with DAT were subdivided on the results of their score on the Japanese version of Alzheimer's Disease Assessment Scale (ADAS-J cog.), into mild (score lower than or equal to 15, n=47), moderate (score 16 to 35, n=63), and severe (score greater than or equal to 36, n=12) groups. Seventy age-matched controls who had no signs or symptoms of dementia were recruited from the Memory Clinic. The reconstructed {sup 123}I-IMP-SPECT data were analyzed using a statistical parametric mapping technique. In mild stage of DAT, SPM analysis demonstrated that bilateral posterior parietal lobes, superior occipital lobes, and posterior cingulated gyri were significantly decreased in CBF as compared with the normal controls. In moderate stage of DAT, extension of the hypoperfusion to the frontal lobes was detected as compared with the mild stage of DAT. In severe stage of DAT, SPM image showed the diffuse hypoperfusion in bilateral hemispheres. The frequency of hypoperfusions in the DAT group was observed with the following: 15.0% in the mild stage, 34.9% in the moderate stage, and 66.7% in the severe stage. Our results indicate that the frequency and progression of the hypoperfusion in the temporoparietal regions and/or the other regions in DAT is related to the severity of the dementia. (author)

  1. Cerebral blood flow imaging in staging of dementia of Alzheimer type. A study using statistical parametric mapping (SPM)

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Daitoh, Nobuyuki; Gotoh, Chiharu; Yokoyama, Sakura

    2001-01-01

    One hundred twenty-two patients with dementia of Alzheimer type (DAT) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All fulfilled the NINCDS-ADRDA diagnostic criteria for probable Alzheimer's disease. Patients with DAT were subdivided on the results of their score on the Japanese version of Alzheimer's Disease Assessment Scale (ADAS-J cog.), into mild (score lower than or equal to 15, n=47), moderate (score 16 to 35, n=63), and severe (score greater than or equal to 36, n=12) groups. Seventy age-matched controls who had no signs or symptoms of dementia were recruited from the Memory Clinic. The reconstructed 123 I-IMP-SPECT data were analyzed using a statistical parametric mapping technique. In mild stage of DAT, SPM analysis demonstrated that bilateral posterior parietal lobes, superior occipital lobes, and posterior cingulated gyri were significantly decreased in CBF as compared with the normal controls. In moderate stage of DAT, extension of the hypoperfusion to the frontal lobes was detected as compared with the mild stage of DAT. In severe stage of DAT, SPM image showed the diffuse hypoperfusion in bilateral hemispheres. The frequency of hypoperfusions in the DAT group was observed with the following: 15.0% in the mild stage, 34.9% in the moderate stage, and 66.7% in the severe stage. Our results indicate that the frequency and progression of the hypoperfusion in the temporoparietal regions and/or the other regions in DAT is related to the severity of the dementia. (author)

  2. X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability

    International Nuclear Information System (INIS)

    Chun, In Kon; Cho, Myung Hye; Lee, Sang Chul; Cho, Min Hyoung; Lee, Soo Yeol

    2004-01-01

    Since a micro-tomography system capable of μm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm -1 suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies

  3. A fractal-based image encryption system

    KAUST Repository

    Abd-El-Hafiz, S. K.; Radwan, Ahmed Gomaa; Abdel Haleem, Sherif H.; Barakat, Mohamed L.

    2014-01-01

    single-fractal image and statistical analysis is performed. A general encryption system utilising multiple fractal images is, then, introduced to improve the performance and increase the encryption key up to hundreds of bits. This improvement is achieved

  4. Intellectual system for images restoration

    Science.gov (United States)

    Mardare, Igor

    2005-02-01

    Intelligence systems on basis of artificial neural networks and associative memory allow to solve effectively problems of recognition and restoration of images. However, within analytical technologies there are no dominating approaches of deciding of intellectual problems. Choice of the best technology depends on nature of problem, features of objects, volume of represented information about the object, number of classes of objects, etc. It is required to determine opportunities, preconditions and field of application of neural networks and associative memory for decision of problem of restoration of images and to use their supplementary benefits for further development of intelligence systems.

  5. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  6. Quantification of image persistence in a digital angiography system

    International Nuclear Information System (INIS)

    Okkalides, D.P.; Raptou, P.D.

    1993-01-01

    Image persistence, as a characteristic of video imaging systems affecting the quality of fast moving fluoroscopic images, is shown to vary considerably. A simple quantitative method for measuring image persistence in a digital angiography system is presented, together with a series of image intensifier exposure-response curves. For the Saticon tube, used with the Siemens 3VA Digitron, it was found that persistence increased for low exposure rates and may increase to 31% at a 120 ms interval. In addition, a sharp increase in image persistence, from 8.3% to 33%, was observed within 18 months from installation of the system. (author)

  7. Imaging of Myocardial Fibrosis in Patients with End-Stage Renal Disease: Current Limitations and Future Possibilities

    Directory of Open Access Journals (Sweden)

    M. P. M. Graham-Brown

    2017-01-01

    Full Text Available Cardiovascular disease in patients with end-stage renal disease (ESRD is driven by a different set of processes than in the general population. These processes lead to pathological changes in cardiac structure and function that include the development of left ventricular hypertrophy and left ventricular dilatation and the development of myocardial fibrosis. Reduction in left ventricular hypertrophy has been the established goal of many interventional trials in patients with chronic kidney disease, but a recent systematic review has questioned whether reduction of left ventricular hypertrophy improves cardiovascular mortality as previously thought. The development of novel imaging biomarkers that link to cardiovascular outcomes and that are specific to the disease processes in ESRD is therefore required. Postmortem studies of patients with ESRD on hemodialysis have shown that the extent of myocardial fibrosis is strongly linked to cardiovascular death and accurate imaging of myocardial fibrosis would be an attractive target as an imaging biomarker. In this article we will discuss the current imaging methods available to measure myocardial fibrosis in patients with ESRD, the reliability of the techniques, specific challenges and important limitations in patients with ESRD, and how to further develop the techniques we have so they are sufficiently robust for use in future clinical trials.

  8. Method and system for dual resolution translation stage

    Science.gov (United States)

    Halpin, John Michael

    2014-04-22

    A dual resolution translation stage includes a stage assembly operable to receive an optical element and a low resolution adjustment device mechanically coupled to the stage assembly. The dual resolution stage also includes an adjustable pivot block mechanically coupled to the stage assembly. The adjustable pivot block includes a pivot shaft. The dual resolution stage further includes a lever arm mechanically coupled to the adjustable pivot block. The lever arm is operable to pivot about the pivot shaft. The dual resolution stage additionally includes a high resolution adjustment device mechanically coupled to the lever arm and the stage assembly.

  9. A review of imaging techniques for systems biology

    Directory of Open Access Journals (Sweden)

    Po Ming J

    2008-08-01

    Full Text Available Abstract This paper presents a review of imaging techniques and of their utility in system biology. During the last decade systems biology has matured into a distinct field and imaging has been increasingly used to enable the interplay of experimental and theoretical biology. In this review, we describe and compare the roles of microscopy, ultrasound, CT (Computed Tomography, MRI (Magnetic Resonance Imaging, PET (Positron Emission Tomography, and molecular probes such as quantum dots and nanoshells in systems biology. As a unified application area among these different imaging techniques, examples in cancer targeting are highlighted.

  10. Whole-body CT for lymphoma staging: Feasibility of halving radiation dose and risk by iterative image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, M., E-mail: mathias.meyer@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Klein, S.A., E-mail: stefan.klein@umm.de [Department of Hematology and Oncology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Brix, G., E-mail: gbrix@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Neuherberg (Germany); Fink, C., E-mail: Christian.Fink@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Pilz, L., E-mail: lothar.pilz@medma.uni-heidelberg.de [Department of Biostatistics, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Jafarov, H., E-mail: Hashim.Jafarov@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Hofmann, W.K., E-mail: w.k.hofmann@umm.de [Department of Hematology and Oncology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoenberg, S.O., E-mail: Stefan.Schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); and others

    2014-02-15

    Objectives: Patients with lymphoma are at higher-risk of secondary malignancies mainly due to effects of cancer therapy as well as frequent radiological surveillance. We thus aimed to investigate the objective and subjective image quality as well as radiation exposure and risk of full-dose standard (FDS), full-dose iterative (FDI), and half-dose iterative (HDI) image reconstruction in patients with lymphoma. Material and methods: In 100 lymphoma patients, contrast-enhanced whole-body staging was performed on a dual-source CT. To acquire full-dose and half-dose CT data simultaneously, the total current-time product was equally distributed on both tubes operating at 120 kV. HDI reconstructions were calculated by using only data from one tube. Quantitative image quality was assessed by measuring image noise in different tissues of the neck, thorax, and abdomen. Overall diagnostic image quality was assessed using a 5-point Likert scale. Radiation doses and risks were estimated for a male and female reference person. Results: For all anatomical regions apart from the lungs image noise was significantly lower and the overall subjective image quality significantly better when using FDI and HDI instead of FDS reconstruction (p < 0.05). For the half-dose protocol, the risk to develop a radiation-induced cancer was estimated to be less than 0.11/0.19% for an adult male/female. Conclusions: Image quality of FDI and more importantly of HDI is superior to FDS reconstruction, thus enabling to halve radiation dose and risk to lymphoma patients.

  11. Deep learning for staging liver fibrosis on CT: a pilot study.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Kunimatsu, Akira; Abe, Osamu; Kiryu, Shigeru

    2018-05-14

    To investigate whether liver fibrosis can be staged by deep learning techniques based on CT images. This clinical retrospective study, approved by our institutional review board, included 496 CT examinations of 286 patients who underwent dynamic contrast-enhanced CT for evaluations of the liver and for whom histopathological information regarding liver fibrosis stage was available. The 396 portal phase images with age and sex data of patients (F0/F1/F2/F3/F4 = 113/36/56/66/125) were used for training a deep convolutional neural network (DCNN); the data for the other 100 (F0/F1/F2/F3/F4 = 29/9/14/16/32) were utilised for testing the trained network, with the histopathological fibrosis stage used as reference. To improve robustness, additional images for training data were generated by rotating or parallel shifting the images, or adding Gaussian noise. Supervised training was used to minimise the difference between the liver fibrosis stage and the fibrosis score obtained from deep learning based on CT images (F DLCT score) output by the model. Testing data were input into the trained DCNNs to evaluate their performance. The F DLCT scores showed a significant correlation with liver fibrosis stage (Spearman's correlation coefficient = 0.48, p deep learning model based on CT images, with moderate performance. • Liver fibrosis can be staged by a deep learning model based on magnified CT images including the liver surface, with moderate performance. • Scores from a trained deep learning model showed moderate correlation with histopathological liver fibrosis staging. • Further improvement are necessary before utilisation in clinical settings.

  12. Magnetic resonance imaging of central nervous system haemorrhage

    International Nuclear Information System (INIS)

    Silberstein, M.; Hennessy, O.

    1993-01-01

    The variable magnetic resonance imaging appearances of central nervous system haemorrhage, both intra- and extra-axial, are described. These will vary with the type of image contrast (T1 or T2 weighting), the nature of the imaging sequence (spin-echo or gradient-echo) and the time from onset of haemorrhage. Magnetic resonance imaging is a useful technique for imaging haemorrhage in the central nervous system as it yields temporal information about haematoma development, and it is the only non-invasive means of imaging intraspinal haemorrhage. However, in the imaging of haematomas within 24 h of onset and in subarachnoid haemorrhage computed tomography is the investigation of choice. 13 refs., 6 figs

  13. Enhancement system of nighttime infrared video image and visible video image

    Science.gov (United States)

    Wang, Yue; Piao, Yan

    2016-11-01

    Visibility of Nighttime video image has a great significance for military and medicine areas, but nighttime video image has so poor quality that we can't recognize the target and background. Thus we enhance the nighttime video image by fuse infrared video image and visible video image. According to the characteristics of infrared and visible images, we proposed improved sift algorithm andαβ weighted algorithm to fuse heterologous nighttime images. We would deduced a transfer matrix from improved sift algorithm. The transfer matrix would rapid register heterologous nighttime images. And theαβ weighted algorithm can be applied in any scene. In the video image fusion system, we used the transfer matrix to register every frame and then used αβ weighted method to fuse every frame, which reached the time requirement soft video. The fused video image not only retains the clear target information of infrared video image, but also retains the detail and color information of visible video image and the fused video image can fluency play.

  14. Parameter Optimization of Multi-Element Synthetic Aperture Imaging Systems

    Directory of Open Access Journals (Sweden)

    Vera Behar

    2007-03-01

    Full Text Available In conventional ultrasound imaging systems with phased arrays, the further improvement of lateral resolution requires enlarging of the number of array elements that in turn increases both, the complexity and the cost, of imaging systems. Multi-element synthetic aperture focusing (MSAF systems are a very good alternative to conventional systems with phased arrays. The benefit of the synthetic aperture is in reduction of the system complexity, cost and acquisition time. In a MSAF system considered in the paper, a group of elements transmit and receive signals simultaneously, and the transmit beam is defocused to emulate a single element response. The echo received at each element of a receive sub-aperture is recorded in the computer memory. The process of transmission/reception is repeated for all positions of a transmit sub-aperture. All the data recordings associated with each corresponding pair "transmit-receive sub-aperture" are then focused synthetically producing a low-resolution image. The final high-resolution image is formed by summing of the all low-resolution images associated with transmit/receive sub-apertures. A problem of parameter optimization of a MSAF system is considered in this paper. The quality of imaging (lateral resolution and contrast is expressed in terms of the beam characteristics - beam width and side lobe level. The comparison between the MSAF system described in the paper and an equivalent conventional phased array system shows that the MSAF system acquires images of equivalent quality much faster using only a small part of the power per image.

  15. Ultrasound Vector Flow Imaging: Part II: Parallel Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.

    2016-01-01

    The paper gives a review of the current state-of-theart in ultrasound parallel acquisition systems for flow imaging using spherical and plane waves emissions. The imaging methods are explained along with the advantages of using these very fast and sensitive velocity estimators. These experimental...... ultrasound imaging for studying brain function in animals. The paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed....

  16. Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

    International Nuclear Information System (INIS)

    Zhang, Ning; Yin, Shao-You; Zhang, Li-Zhi

    2016-01-01

    Graphical abstract: A heat pump driven, hollow fiber membrane-based two-stage liquid desiccant air dehumidification system. - Highlights: • A two-stage hollow fiber membrane based air dehumidification is proposed. • It is heat pump driven liquid desiccant system. • Performance is improved 20% upon single stage system. • The optimal first to second stage dehumidification area ratio is 1.4. - Abstract: A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi-isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286.

  17. Real-time beam profile imaging system for actinotherapy accelerator

    International Nuclear Information System (INIS)

    Lin Yong; Wang Jingjin; Song Zheng; Zheng Putang; Wang Jianguo

    2003-01-01

    This paper describes a real-time beam profile imaging system for actinotheraphy accelerator. With the flash X-ray imager and the technique of digital image processing, a real-time 3-dimension dosage image is created from the intensity profile of the accelerator beam in real time. This system helps to obtain all the physical characters of the beam in any section plane, such as FWHM, penumbra, peak value, symmetry and homogeneity. This system has been used to acquire a 3-dimension dosage distribution of dynamic wedge modulator and the transient process of beam dosage. The system configure and the tested beam profile images are also presented

  18. Nitrogen removal and microbial communities in a three-stage system simulating a riparian environment.

    Science.gov (United States)

    Wang, Ziyuan; Wang, Zhixin; Pei, Yuansheng

    2014-06-01

    The riparian zone is an active interface for nitrogen removal, in which nitrogen transformations by microorganisms have not been valued. In this study, a three-stage system was constructed to simulate the riparian zone environments, and nitrogen removal as well as the microbial community was investigated in this 'engineered riparian system'. The results demonstrated that stage 1 of this system accounted for 41-51 % of total nitrogen removal. Initial ammonium loading and redox potential significantly impacted the nitrogen removal performances. Stages 1 and 2 were both composed of an anoxic/oxic (A/O) zone and an anaerobic column. The A/O zone removed most of the ammonium load (6.8 g/m(2)/day), while the anaerobic column showed a significant nitrate removal rate (11.1 g/m(2)/day). Molecular biological analysis demonstrated that bacterial diversity was high in the A/O zones, where ammonium-oxidizing bacteria and nitrite-oxidizing bacteria accounted for 8.42 and 3.32 % of the bacterial population, respectively. The denitrifying bacteria Acidovorax sp. and the nitrifying bacteria Nitrosospira/Nitrosomonas were the predominant microorganisms in this engineered riparian system. This three-stage system was established to achieve favorable nitrogen removal and the microbial community in the system was also retained. This investigation should deepen our understanding of biological nitrogen removal in engineered riparian zones.

  19. Toward objective and quantitative evaluation of imaging systems using images of phantoms

    International Nuclear Information System (INIS)

    Gagne, Robert M.; Gallas, Brandon D.; Myers, Kyle J.

    2006-01-01

    The use of imaging phantoms is a common method of evaluating image quality in the clinical setting. These evaluations rely on a subjective decision by a human observer with respect to the faintest detectable signal(s) in the image. Because of the variable and subjective nature of the human-observer scores, the evaluations manifest a lack of precision and a potential for bias. The advent of digital imaging systems with their inherent digital data provides the opportunity to use techniques that do not rely on human-observer decisions and thresholds. Using the digital data, signal-detection theory (SDT) provides the basis for more objective and quantitative evaluations which are independent of a human-observer decision threshold. In a SDT framework, the evaluation of imaging phantoms represents a 'signal-known-exactly/background-known-exactly' ('SKE/BKE') detection task. In this study, we compute the performance of prewhitening and nonprewhitening model observers in terms of the observer signal-to-noise ratio (SNR) for these 'SKE/BKE' tasks. We apply the evaluation methods to a number of imaging systems. For example, we use data from a laboratory implementation of digital radiography and from a full-field digital mammography system in a clinical setting. In addition, we make a comparison of our methods to human-observer scoring of a set of digital images of the CDMAM phantom available from the internet (EUREF--European Reference Organization). In the latter case, we show a significant increase in the precision of the quantitative methods versus the variability in the scores from human observers on the same set of images. As regards bias, the performance of a model observer estimated from a finite data set is known to be biased. In this study, we minimize the bias and estimate the variance of the observer SNR using statistical resampling techniques, namely, 'bootstrapping' and 'shuffling' of the data sets. Our methods provide objective and quantitative evaluation of

  20. Portable remote sensing image processing system; Kahangata remote sensing gazo shori system

    Energy Technology Data Exchange (ETDEWEB)

    Fujikawa, S; Uchida, K; Tanaka, S; Jingo, H [Dowa Engineering Co. Ltd., Tokyo (Japan); Hato, M [Earth Remote Sensing Data Analysis Center, Tokyo (Japan)

    1997-10-22

    Recently, geological analysis using remote sensing data has been put into practice due to data with high spectral resolution and high spatial resolution. There has been a remarkable increase in both software and hardware of personal computer. Software is independent of hardware due to Windows. It has become easy to develop softwares. Under such situation, a portable remote sensing image processing system coping with Window 95 has been developed. Using this system, basic image processing can be conducted, and present location can be displayed on the image in real time by linking with GPS. Accordingly, it is not required to bring printed images for the field works of image processing. This system can be used instead of topographic maps for overseas surveys. Microsoft Visual C++ ver. 2.0 is used for the software. 1 fig.