WorldWideScience

Sample records for stack instrumental methods

  1. Laser pulse stacking method

    Science.gov (United States)

    Moses, E.I.

    1992-12-01

    A laser pulse stacking method is disclosed. A problem with the prior art has been the generation of a series of laser beam pulses where the outer and inner regions of the beams are generated so as to form radially non-synchronous pulses. Such pulses thus have a non-uniform cross-sectional area with respect to the outer and inner edges of the pulses. The present invention provides a solution by combining the temporally non-uniform pulses in a stacking effect to thus provide a more uniform temporal synchronism over the beam diameter. 2 figs.

  2. Method for monitoring stack gases for uranium activity

    International Nuclear Information System (INIS)

    Beverly, C.R.; Ernstberger, H.G.

    1988-01-01

    A method for sampling stack gases emanating from the purge cascade of a gaseous diffusion cascade system utilized to enrich uranium for determining the presence and extent of uranium in the stack gases in the form of gaseous uranium hexafluoride, is described comprising the steps of removing a side stream of gases from the stack gases, contacting the side stream of the stack gases with a stream of air sufficiently saturated with moisture for reacting with and converting any gaseous uranium hexafluroide contracted thereby in the side stream of stack gases to particulate uranyl fluoride. Thereafter contacting the side stream of stack gases containing the particulate uranyl fluoride with moving filter means for continuously intercepting and conveying the intercepted particulate uranyl fluoride away from the side stream of stack gases, and continually scanning the moving filter means with radiation monitoring means for sensing the presence and extent of particulate uranyl fluoride on the moving filter means which is indicative of the extent of particulate uranyl fluoride in the side stream of stack gases which in turn is indicative of the presence and extent of uranium hexafluoride in the stack gases

  3. Continued SOFC cell and stack technology and improved production methods

    Energy Technology Data Exchange (ETDEWEB)

    Wandel, M.; Brodersen, K.; Phair, J. (and others)

    2009-05-15

    Within this project significant results are obtained on a number of very diverse areas ranging from development of cell production, metallic creep in interconnect to assembling and test of stacks with foot print larger than 500 cm2. Out of 38 milestones 28 have been fulfilled and 10 have been partly fulfilled. This project has focused on three main areas: 1) The continued cell development and optimization of manufacturing processes aiming at production of large foot-print cells, improving cell performance and development environmentally more benign production methods. 2) Stack technology - especially stacks with large foot print and improving the stack design with respect to flow geometry and gas leakages. 3) Development of stack components with emphasis on sealing (for 2G as well as 3G), interconnect (coat, architecture and creep) and test development. Production of cells with a foot print larger than 500 cm2 is very difficult due to the brittleness of the cells and great effort has been put into this topic. Eight cells were successfully produced making it possible to assemble and test a real stack thereby giving valuable results on the prospects of stacks with large foot print. However, the yield rate is very low and a significant development to increase this yield lies ahead. Several lessons were learned on the stack level regarding 'large foot print' stacks. Modelling studies showed that the width of the cell primarily is limited by production and handling of the cell whereas the length (in the flow direction) is limited by e.g. pressure drop and necessary manifolding. The optimal cell size in the flow direction was calculated to be between approx20 cm and < 30 cm. From an economical point of view the production yield is crucial and stacks with large foot print cell area are only feasible if the cell production yield is significantly enhanced. Co-casting has been pursued as a production technique due to the possibilities in large scale production

  4. Luminescence techniques: Instrumentation and methods

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    1997-01-01

    This paper describes techniques, instruments and methods used in luminescence dating and environmental dosimetry in many laboratories around the world. These techniques are based on two phenomena - thermally stimulated luminescence and optically stimulated luminescence. The most commonly used...... luminescence stimulation and detection techniques are reviewed and information is given on recent developments in instrument design and on the stale of the art in luminescence measurements and analysis. (C) 1998 Elsevier Science Ltd. All rights reserved....

  5. Improved exact method for the double TSP with multiple stacks

    DEFF Research Database (Denmark)

    Lusby, Richard Martin; Larsen, Jesper

    2011-01-01

    The Double TSP with Multiple Stacks is a logistics problem where one must, using a container, transport a given number of orders from a set of pickup customers to a set of delivery customers at minimum cost. Each order corresponds to the movement of one pallet, all pickups must be completed before...... the first delivery, and the container cannot be repacked once packed. In this paper we improve the previously proposed exact method of Lusby et al. (Int Trans Oper Res 17 (2010), 637–652) through an additional preprocessing technique that uses the longest common subsequence between the respective pickup...... and delivery problems. The results suggest an impressive improvement, and we report, for the first time, optimal solutions to several unsolved instances from the literature containing 18 customers. Instances with 28 customers are also shown to be solvable within a few percent of optimality. © 2011 Wiley...

  6. A new method for beam stacking in storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, C.M.; /Fermilab

    2008-06-01

    Recently, I developed a new beam stacking scheme for synchrotron storage rings called 'longitudinal phase-space coating' (LPSC). This scheme has been convincingly validated by multi-particle beam dynamics simulations and has been demonstrated with beam experiments at the Fermilab Recycler. Here, I present the results from both simulations and experiments. The beam stacking scheme presented here is the first of its kind.

  7. Very Weak Signals (VWS detected by stacking method according to different astronomical periodicities (HiCum

    Directory of Open Access Journals (Sweden)

    M. van Ruymbeke

    2007-11-01

    Full Text Available A stacking method to detect very weak signals is introduced in this paper. This method is to stack observed data in different well known periodicities according to the astronomical clock since majority geophysical observations are time based. We validated this method by applying it in four different cases. Interactions behind the observed parameters become obviously after it is stacked in two diurnal and semidiurnal tidal periodical waves. Amplitude and phase variations will be also measurable when a sliding windows stacking is used. This could be an important reference to find precursors before some earthquakes and volcanic events, corresponding to attenuations of medium patterns.

  8. Volume 1: Instrumentation and Methods

    CERN Document Server

    Luysberg, Martina; Weirich, Thomas; EMC 2008 14th European Microscopy Congress

    2008-01-01

    Proceedings of the14th European Microscopy Congress, held in Aachen, Germany, 1-5 September 2008. Jointly organised by the European Microscopy Society (EMS), the German Society for Electron Microscopy (DGE) and the local microscopists from RWTH Aachen University and the Research Centre Jülich, the congress brings together scientists from Europe and from all over the world. The scientific programme covers all recent developments in the three major areas of instrumentation and methods, materials science and life science.

  9. A method of measuring stacked objects volume based on laser sensing

    Science.gov (United States)

    Zhao, Qijie; Wu, Yijing; Li, Xianfa; Xu, Jiao; Meng, Qingxu

    2017-10-01

    Stacked objects volume measurement is now widely used in the fields of enterprise material management. It is significant to improve the efficiency of enterprise management and to reduce the cost of management and operation. The method based on laser sensing is one of the key methods to measure the stacked objects volume. This paper presents a laser sensing measurement method of stacked objects based on bottom plane extraction and real-time calibration. A calibration method for a laser scanning sensor and inertial measurement sensor is proposed. Three-dimensional reconstructions of stacked objects and volume calculations are carried out after acquisition and processing of point clouds. Volume measurement experiments of the single box and stacked boxes have been conducted respectively. Experimental results show that the measurement method is feasible and valid with good accuracy.

  10. An Exact Method for the Double TSP with Multiple Stacks

    DEFF Research Database (Denmark)

    Larsen, Jesper; Lusby, Richard Martin; Ehrgott, Matthias

    The double travelling salesman problem with multiple stacks (DTSPMS) is a pickup and delivery problem in which all pickups must be completed before any deliveries can be made. The problem originates from a real-life application where a 40 foot container (configured as 3 columns of 11 rows) is used...

  11. An Exact Method for the Double TSP with Multiple Stacks

    DEFF Research Database (Denmark)

    Lusby, Richard Martin; Larsen, Jesper; Ehrgott, Matthias

    2010-01-01

    The double travelling salesman problem with multiple stacks (DTSPMS) is a pickup and delivery problem in which all pickups must be completed before any deliveries can be made. The problem originates from a real-life application where a 40 foot container (configured as 3 columns of 11 rows) is used...

  12. Development of a Three Dimensional Neural Sensing Device by a Stacking Method

    Directory of Open Access Journals (Sweden)

    Chih-Wei Chang

    2010-04-01

    Full Text Available This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interconnection for 3-D signal transmission, low structure strength and large implantable opening. By applying the proposed stacking method, the previous techniques could be replaced by 2-D wire bonding. In this way, supporting platforms with slots and vertical spacers were no longer needed. Furthermore, ASIC chips can be substituted for the spacers in the stacked arrays to achieve system integration, design flexibility and volume usage efficiency. To avoid overflow of the adhesive fluid during assembly, an anti-overflow design which made use of capillary action force was applied in the stacking method as well. Moreover, presented stacking procedure consumes only 35 minutes in average for a 4 × 4 3-D microprobe array without requiring other specially made assembly tools. To summarize, the advantages of the proposed stacking method for 3-D array assembly include simplified assembly process, high structure strength, smaller opening area and integration ability with active circuits. This stacking assembly technique allows an alternative method to create 3-D structures from planar components.

  13. Bubble measuring instrument and method

    Science.gov (United States)

    Kline-Schoder, Robert (Inventor); Magari, Patrick J. (Inventor)

    2003-01-01

    Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

  14. A new method to determine earthquake depth: stacking multiple-station autocorrelogram

    Science.gov (United States)

    Zhang, M.; Tian, D.; Wen, L.

    2013-12-01

    Accurate determination of source depth of the earthquakes in the crust is still challenging, because of our imperfect knowledge of velocity structure and unclear depth phase of the earthquakes. We develop a new method to determine earthquake source depth, based on stacking multiple-station autocorrelogram (SMAC). We determine source depth using both direct SH wave and its coda. In coda wave interferometry, the stacking of the cross-correlograms of two earthquake coda can be treated as the Green's function from one earthquake to the other. The stacking of the autocorrelograms of an earthquake coda can thus be treated as the Green's function from the earthquake to itself. By stacking autocorrelograms of SH wave coda recorded at each station, we retrieve the surface reflection from the source and back to the source, which is used to determine the source depth. In the stacking of direct wave autocorrelograms, the time difference between the surface reflection and the main wave would depend on source depth, Moho depth and epicentral distance. We derive travel time difference between the surface reflection and the main SH wave by grid-searching those parameters. The autocorrelograms are stacked along the theoretical travel times predicted based on each source depth, Moho depth and epicentral distance. The source depth in the set of the parameters that gives the most prominent stacking energy is regarded as the best-fitting source depth. We demonstrate the validity of SMAC in both synthetics and actual data for an earthquake occurring in Japan Island.

  15. Frequency domain method for the stack of seismic and radar data

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, H.; Sato, M. [Tohoku University, Sendai (Japan); Xu, S.

    1997-10-22

    With relation to the stacking method of elastic wave and radar wave, the frequency domain stacking method using the Fourier conversion was proposed as a method for automatically removing errors in time correction leaving advantages of the conventional horizontal stacking method. Concerning an example of wave motion with the same wave form and time difference, as a result of the analysis conducted by this method, it was found that not only effects are kept of suppressing random noise and regular noise in the conventional horizontal stacking method, but the resolution in the original wave motion data is kept. In the example, amplitude of the noise was a half of the wave motion signal, but if it is more than 0.85 times of the wave motion signal, favorable result cannot be obtained in this method. In the analysis in the area where time correction is very difficult and the correction cannot be made completely, it is useful also for the time domain stacking method to acquire data on high resolution of elastic wave and radar wave. 4 refs., 2 figs.

  16. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  17. Pixe method as microanalytical instrument

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1986-02-01

    The PIXE method (Particle Induced X-Ray Emission) as analytical method presenting the evolution, the theoretical fundaments, the detection limit, the optimization for operational conditions is evaluated. The applications of the method to air pollution control and aerosol studies in regions such as Antartic, Amazon and other regions are analysed. (M.C.K.) [pt

  18. A Force Sensorless Method for CFRP/Ti Stack Interface Detection during Robotic Orbital Drilling Operations

    Directory of Open Access Journals (Sweden)

    Qiang Fang

    2015-01-01

    Full Text Available Drilling carbon fiber reinforced plastics and titanium (CFRP/Ti stacks is one of the most important activities in aircraft assembly. It is favorable to use different drilling parameters for each layer due to their dissimilar machining properties. However, large aircraft parts with changing profiles lead to variation of thickness along the profiles, which makes it challenging to adapt the cutting parameters for different materials being drilled. This paper proposes a force sensorless method based on cutting force observer for monitoring the thrust force and identifying the drilling material during the drilling process. The cutting force observer, which is the combination of an adaptive disturbance observer and friction force model, is used to estimate the thrust force. An in-process algorithm is developed to monitor the variation of the thrust force for detecting the stack interface between the CFRP and titanium materials. Robotic orbital drilling experiments have been conducted on CFRP/Ti stacks. The estimate error of the cutting force observer was less than 13%, and the stack interface was detected in 0.25 s (or 0.05 mm before or after the tool transited it. The results show that the proposed method can successfully detect the CFRP/Ti stack interface for the cutting parameters adaptation.

  19. A stacked sequential learning method for investigator name recognition from web-based medical articles

    Science.gov (United States)

    Zhang, Xiaoli; Zou, Jie; Le, Daniel X.; Thoma, George

    2010-01-01

    "Investigator Names" is a newly required field in MEDLINE citations. It consists of personal names listed as members of corporate organizations in an article. Extracting investigator names automatically is necessary because of the increasing volume of articles reporting collaborative biomedical research in which a large number of investigators participate. In this paper, we present an SVM-based stacked sequential learning method in a novel application - recognizing named entities such as the first and last names of investigators from online medical journal articles. Stacked sequential learning is a meta-learning algorithm which can boost any base learner. It exploits contextual information by adding the predicted labels of the surrounding tokens as features. We apply this method to tag words in text paragraphs containing investigator names, and demonstrate that stacked sequential learning improves the performance of a nonsequential base learner such as an SVM classifier.

  20. Application of Stacking Technique in ANA: Method and Practice with PKU Seismological Array

    Science.gov (United States)

    Liu, J.; Tang, Y.; Ning, J.; Chen, Y. J.

    2010-12-01

    Cross correlation of ambient noise records is now routinely used to get dispersion curve and then do seismic tomography; however little attention has been paid to array techniques. We will present a spacial-stacking method to get high resolution dispersion curves and show practices with the observation data of PKU seismological array. Experiential Green Functions are generally obtained by correlation between two stations, and then the dispersion curves are obtained from the analysis of FTAN. Popular method to get high resolution dispersion curves is using long time records. At the same time, if we want to get effectual signal, the distance between the two stations must be at least 3 times of the longest wavelength. So we need both long time records and appropriate spaced stations. Now we use a new method, special-stacking, which allows shorter observation period and utilizes observations of a group of closely distributed stations to get fine dispersion curves. We correlate observations of every station in the station group with those of a far station, and then stack them together. However we cannot just simply stack them unless the stations in the station group at a circle, of which the center is the far station owing to dispersion characteristics of the Rayleigh waves. Thus we do antidispersion on the observation data of every station in the array, then do stacking. We test the method using the theoretical seismic surface wave records which obtained by qseis06 compiled by Rongjiang Wang both with and without noise. For the cases of three imaginary stations (distance is 1 degree) have the same underground structure and without noise, result is that the center station had the same dispersion with and without spacial-stacking. Then we add noise to the theoretical records. The center station's dispersion curves obtained by our method are much closer to the dispersion curve without noise than contaminated ones. We can see that our method has improved the resolution of

  1. A new method for earthquake depth determination: stacking multiple-station autocorrelograms

    Science.gov (United States)

    Zhang, Miao; Tian, Dongdong; Wen, Lianxing

    2014-05-01

    Accurate determination of earthquake depth is important, but particularly challenging. We develop a new method to determine the earthquake source depth by stacking multiple-station autocorrelograms (SMAC) of seismic data. The basic concept of SMAC method is to enhance the coherent surface reflected energy by autocorrelation and stacking, and uses the surface reflected energy to determine the source depth. Autocorrelation effectively enhances the energy of the seismic phases related to the source depth, while stacking the autocorrelograms of array data further improves the signal-to-noise ratio of the energy. The procedures are applied using both the main SH waves and the coda. Using coda waves, the method extracts the two-way traveltime between the source and the surface by stacking the coda wave autocorrelations over an array of seismic observations. Using the main SH waves, SMAC explores the interference of the down-going Moho reflected SmS wave and up-going surface bounced Moho reflected sSmS wave by autocorrelation. The autocorrelograms are then stacked along theoretical differential sSmS-SmS traveltime predicted for all potential source depths, and the source depth is determined to be the one that produces the maximum stacking energy. Synthetic tests demonstrate the validity of the SMAC procedures. As an example of application, we apply the SMAC method to determine the source depth of an earthquake occurring in Japan Island. The procedures of using both main SH waves and their coda waves yield robust surface reflected energy and a consistent source depth. The error of the depth estimation is less than 1 km assuming an uncertainty of 10 per cent in the averaged crust velocity.

  2. Digital processing method for monitoring the radioactivity of stack releases

    International Nuclear Information System (INIS)

    Vialettes, H.; Leblanc, P.; Perotin, J.P.; Lazou, J.P.

    1978-01-01

    The digital processing method proposed is adapted for data supplied by a fixed-filter detector normally used for analogue processing (integrator system). On the basis of the raw data (pulses) from the detector, the technique makes it possible to determine the rate of activity released whereas analogue processing gives only the released activity. Furthermore, the method can be used to develop alarm systems on the basis of a possible exposure rate at the point of fall-out, and by including in the program a coefficient which allows for atmospheric diffusion conditions at any given time one can improve the accuracy of the results. In order to test the digital processing method and demonstrate its advantages over analogue processing, various atmospheric contamination situations were simulated in a glove-box and analysed simultaneously, using both systems, from the pulses transmitted by the same sampling and fixed-filter detection unit. The experimental results confirm the advantages foreseen in the theoretical research. (author)

  3. Element stacking method for topology optimization with material-dependent boundary and loading conditions

    DEFF Research Database (Denmark)

    Yoon, Gil Ho; Park, Y.K.; Kim, Y.Y.

    2007-01-01

    A new topology optimization scheme, called the element stacking method, is developed to better handle design optimization involving material-dependent boundary conditions and selection of elements of different types. If these problems are solved by existing standard approaches, complicated finite...

  4. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ...) to calculate emission levels at 7 percent oxygen (or an equivalent carbon dioxide basis), the percent... subpart. (c) Obtain an oxygen (or carbon dioxide) measurement at the same time as your pollutant... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack...

  5. 40 CFR 62.15245 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... emission limits in tables 2 and 4 of this subpart. (c) Obtain an oxygen (or carbon dioxide) measurement at... equivalent carbon dioxide basis), the percent reduction in potential hydrogen chloride emissions, and the... 40 Protection of Environment 8 2010-07-01 2010-07-01 false What test methods must I use to stack...

  6. Bacteria detection instrument and method

    Science.gov (United States)

    Renner, W.; Fealey, R. D. (Inventor)

    1972-01-01

    A method and apparatus for screening a sample fluid for bacterial presence are disclosed wherein the fluid sample is mixed with culture media of sufficient quantity to permit bacterial growth in order to obtain a test solution. The concentration of oxygen dissolved in the test solution is then monitored using the potential difference between a reference electrode and a noble metal electrode which are in contact with the test solution. The change in oxygen concentration which occurs during a period of time as indicated by the electrode potential difference is compared with a detection criterion which exceeds the change which would occur absent bacteria.

  7. Computerized method and system for designing an aerodynamic focusing lens stack

    Science.gov (United States)

    Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA

    2011-11-22

    A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.

  8. Comparative Analysis of Direct and Indirect 131I Measurement Methods from the Stack to Outdoor

    Directory of Open Access Journals (Sweden)

    G. Suhariyono

    2017-11-01

    Full Text Available The radioisotope production facility at PUSPIPTEK Serpong produces and processes 131I that can disperse to the settlements (community and the environment around the Serpong Nuclear Area (SNA. 131I is produced routinely for medical uses in hospitals and pharmacies, for both domestic uses and export. 131I is a beta and gamma emitting radioactive material and can cause thyroid cancer. The problem was that there was so far no research and in-depth assessment of the aerial dispersion of 131I radioactivity emitted from the radioisotope production stack to the environment at actual conditions. The research was conducted through simultaneous measurement of 131I radioactivity in the stack of the 131I radioisotope production facility, Serpong, and outdoor in house courtyards around SNA in normal condition (no accident based on the variations of the distance and wind direction. Direct measurements were carried out with a portable in-situ NaI(Tl detector at outdoor, and with a LaBr3 detector in the stack. Indirect measurements were carried out by using charcoal filter and vacuum pump in the stack and outdoor. The direct measurement method has many advantages over the indirect measurement. The direct measurement method was found to be more accurate, less expensive, easier to operate, needing just one operator in its implementation, portable, and can be operated continuously and for long durations. The overall activity concentrations of 131I on average obtained by either direct or indirect method were still below the upper limit of 131I activity concentration in the air (530 Bq/m3 stipulated by the Regulation of the Chairman of BAPETEN (Perka BAPETEN No. 7/2013. 

  9. Scaling of Engineered Vascular Grafts Using 3D Printed Guides and the Ring Stacking Method.

    Science.gov (United States)

    Pinnock, Cameron B; Xu, Zhengfan; Lam, Mai T

    2017-03-27

    Coronary artery disease remains a leading cause of death, affecting millions of Americans. With the lack of autologous vascular grafts available, engineered grafts offer great potential for patient treatment. However, engineered vascular grafts are generally not easily scalable, requiring manufacture of custom molds or polymer tubes in order to customize to different sizes, constituting a time-consuming and costly practice. Human arteries range in lumen diameter from about 2.0-38 mm and in wall thickness from about 0.5-2.5 mm. We have created a method, termed the "Ring Stacking Method," in which variable size rings of tissue of the desired cell type, demonstrated here with vascular smooth muscle cells (SMCs), can be created using guides of center posts to control lumen diameter and outer shells to dictate vessel wall thickness. These tissue rings are then stacked to create a tubular construct, mimicking the natural form of a blood vessel. The vessel length can be tailored by simply stacking the number of rings required to constitute the length needed. With our technique, tissues of tubular forms, similar to a blood vessel, can be readily manufactured in a variety of dimensions and lengths to meet the needs of the clinic and patient.

  10. Intelligent inversion method for pre-stack seismic big data based on MapReduce

    Science.gov (United States)

    Yan, Xuesong; Zhu, Zhixin; Wu, Qinghua

    2018-01-01

    Seismic exploration is a method of oil exploration that uses seismic information; that is, according to the inversion of seismic information, the useful information of the reservoir parameters can be obtained to carry out exploration effectively. Pre-stack data are characterised by a large amount of data, abundant information, and so on, and according to its inversion, the abundant information of the reservoir parameters can be obtained. Owing to the large amount of pre-stack seismic data, existing single-machine environments have not been able to meet the computational needs of the huge amount of data; thus, the development of a method with a high efficiency and the speed to solve the inversion problem of pre-stack seismic data is urgently needed. The optimisation of the elastic parameters by using a genetic algorithm easily falls into a local optimum, which results in a non-obvious inversion effect, especially for the optimisation effect of the density. Therefore, an intelligent optimisation algorithm is proposed in this paper and used for the elastic parameter inversion of pre-stack seismic data. This algorithm improves the population initialisation strategy by using the Gardner formula and the genetic operation of the algorithm, and the improved algorithm obtains better inversion results when carrying out a model test with logging data. All of the elastic parameters obtained by inversion and the logging curve of theoretical model are fitted well, which effectively improves the inversion precision of the density. This algorithm was implemented with a MapReduce model to solve the seismic big data inversion problem. The experimental results show that the parallel model can effectively reduce the running time of the algorithm.

  11. Monitoring Mining Subsidence Using A Combination of Phase-Stacking and Offset-Tracking Methods

    OpenAIRE

    Fan, Hongdong; Gao, Xiaoxiong; Yang, Junkai; Deng, Kazhong; Yu, Yang

    2015-01-01

    An approach to study the mechanism of mining-induced subsidence, using a combination of phase-stacking and sub-pixel offset-tracking methods, is reported. In this method, land subsidence with a small deformation gradient was calculated using time-series differential interferometric synthetic aperture radar (D-InSAR) data, whereas areas with greater subsidence were calculated by a sub-pixel offset-tracking method. With this approach, time-series data for mining subsidence were derived in Yuli...

  12. On-line and real-time diagnosis method for proton membrane fuel cell (PEMFC) stack by the superposition principle

    Science.gov (United States)

    Lee, Young-Hyun; Kim, Jonghyeon; Yoo, Seungyeol

    2016-09-01

    The critical cell voltage drop in a stack can be followed by stack defect. A method of detecting defective cell is the cell voltage monitoring. The other methods are based on the nonlinear frequency response. In this paper, the superposition principle for the diagnosis of PEMFC stack is introduced. If critical cell voltage drops exist, the stack behaves as a nonlinear system. This nonlinearity can explicitly appear in the ohmic overpotential region of a voltage-current curve. To detect the critical cell voltage drop, a stack is excited by two input direct test-currents which have smaller amplitude than an operating stack current and have an equal distance value from the operating current. If the difference between one voltage excited by a test current and the voltage excited by a load current is not equal to the difference between the other voltage response and the voltage excited by the load current, the stack system acts as a nonlinear system. This means that there is a critical cell voltage drop. The deviation from the value zero of the difference reflects the grade of the system nonlinearity. A simulation model for the stack diagnosis is developed based on the SPP, and experimentally validated.

  13. Instruments and method of air navigation

    Science.gov (United States)

    1977-01-01

    Topics discussed include magnetic and astronavigation instruments; flight beyond ground visibility; aircraft radio navigation instruments and communication radio sets; instrument landing systems; and ground controlled landing systems.

  14. Analytic Method for Computing Instrument Pointing Jitter

    Science.gov (United States)

    Bayard, David

    2003-01-01

    A new method of calculating the root-mean-square (rms) pointing jitter of a scientific instrument (e.g., a camera, radar antenna, or telescope) is introduced based on a state-space concept. In comparison with the prior method of calculating the rms pointing jitter, the present method involves significantly less computation. The rms pointing jitter of an instrument (the square root of the jitter variance shown in the figure) is an important physical quantity which impacts the design of the instrument, its actuators, controls, sensory components, and sensor- output-sampling circuitry. Using the Sirlin, San Martin, and Lucke definition of pointing jitter, the prior method of computing the rms pointing jitter involves a frequency-domain integral of a rational polynomial multiplied by a transcendental weighting function, necessitating the use of numerical-integration techniques. In practice, numerical integration complicates the problem of calculating the rms pointing error. In contrast, the state-space method provides exact analytic expressions that can be evaluated without numerical integration.

  15. Imaging, cutting, and collecting instrument and method

    Science.gov (United States)

    Tench, R.J.; Siekhaus, W.J.; Balooch, M.; Balhorn, R.L.; Allen, M.J.

    1995-10-31

    Instrumentation and techniques are described to image small objects, such as but not limited to individual human chromosomes, with nanometer resolution. This instrument and method are also used to cut-off identified parts of objects, to move around and manipulate the cut-off parts on the substrate on which they are being imaged to predetermined locations on the substrate, and to remove the cut-off parts from the substrate. This is accomplished using an atomic force microscope (AFM) and by modification of the conventional cantilever stylus assembly of an AFM. The plural cantilevers are used with either sharp-tips or knife-edges. In addition, the invention can be utilized for measuring the hardness of materials. 10 figs.

  16. Instrumentation and quantitative methods of evaluation

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1991-01-01

    This report summarizes goals and accomplishments of the research program entitled Instrumentation and Quantitative Methods of Evaluation, during the period January 15, 1989 through July 15, 1991. This program is very closely integrated with the radiopharmaceutical program entitled Quantitative Studies in Radiopharmaceutical Science. Together, they constitute the PROGRAM OF NUCLEAR MEDICINE AND QUANTITATIVE IMAGING RESEARCH within The Franklin McLean Memorial Research Institute (FMI). The program addresses problems involving the basic science and technology that underlie the physical and conceptual tools of radiotracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 234 refs., 11 figs., 2 tabs

  17. The Methods of Design and Implementation of Stack Filters for Image Processing

    Directory of Open Access Journals (Sweden)

    S. Marchevsky

    1995-04-01

    Full Text Available This paper deals with a large class of nonlinear digital filters, the stack filters, which contain all combinations and compositions of rank order operators within a finite window. Attention is given to design and effective hardware implementation of an optimal stack filter for image processing. Presented simulation results confirm robustness of stack filters in the image restoration corrupted by impulsive noise.

  18. Detection of Small Sized GEO Debris Using FPGA Based Stacking Method

    Science.gov (United States)

    Yanagisawa, Toshifumi; Hanada, Toshiya; Kurosaki, Hirohisa; Kitazawa, Yukihito; Uetsuhara, Masahiko; Kinoshita, Daisuke

    2012-07-01

    In order to detect faint moving objects such as space debris, asteroids and comet, a FPGA based analysis method has been developed. The original stacking method, which uses multiple images to improve signal-to-noise ratio and runs as a software on PC, has a disadvantage of taking enormous time to analyze. A new algorithm and its installation into a FPGA board solved the problem by reducing analysis time about one thousandth. A collaborative observation between Japan and Taiwan was conducted to search for undiscovered debris fragments generated from a breakup event of US Titan IIIC Transtage. A lot of fragments that may be related to the breakup were discovered by analyzing with the method which verifies the effectiveness of the method.

  19. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  20. A method enabling height-control of chips for edge-emitting laser stacking

    Science.gov (United States)

    Thanh Tung, Bui; Ma, Laina; Amano, Takeru; Kikuchi, Katsuya; Mori, Masahiko; Aoyagi, Masahiro

    2015-04-01

    In this paper we present a stacking method that enables the mounting of edge-emitting laser (EEL) devices at compulsory positions for feeding a coupling waveguide at a low temperature, i.e., 110 °C. Bonding laser chips are integrated to an interposer with embedded waveguides using an electrically conductive adhesive (ECA), i.e., silver-filled epoxy resin that relied on the surface tension phenomenon. A simple dispensing technique based on the capillary effect was used to generate adhesive droplets for bonding purposes. The ability to control the bonding height from 3 to 25 µm was demonstrated. While the post-bond in-plane offsets of the bonding EEL chip are determined by the accuracy of the bonder (i.e., within 2 µm range), the bonding height can be engineered, with a deviation within 1 µm, by balancing the external bonding forces with the surface tension of a certain adhesive volume. The reliability of the bond, i.e., bond strength of 106 gf, and heat dissipation function of the ECA, were also validated. The results obtained in this work imply that the use of this low-temperature, height-controllable approach for the stacking of EEL continues to look highly promising.

  1. Maximizing power production in a stack of microbial fuel cells using multiunit optimization method.

    Science.gov (United States)

    Woodward, Lyne; Perrier, Michel; Srinivasan, Bala; Tartakovsky, Boris

    2009-01-01

    This study demonstrates real-time maximization of power production in a stack of two continuous flow microbial fuel cells (MFCs). To maximize power output, external resistances of two air-cathode membraneless MFCs were controlled by a multiunit optimization algorithm. Multiunit optimization is a recently proposed method that uses multiple similar units to optimize process performance. The experiment demonstrated fast convergence toward optimal external resistance and algorithm stability during external perturbations (e.g., temperature variations). Rate of the algorithm convergence was much faster than in traditional maximum power point tracking algorithms (MPPT), which are based on temporal perturbations. A power output of 81-84 mW/L(A) (A = anode volume) was achieved in each MFC. 2009 American Institute of Chemical Engineers

  2. Method for disclosing invisible physical properties in metal-ferroelectric-insulator-semiconductor gate stacks

    Science.gov (United States)

    Sakai, Shigeki; Zhang, Wei; Takahashi, Mitsue

    2017-04-01

    In metal-ferroelectric-insulator-semiconductor gate stacks of ferroelectric-gate field effect transistors (FeFETs), it is impossible to directly obtain curves of polarization versus electric field (P f-E f) in the ferroelectric layer. The P f-E f behavior is not simple, i.e. the P f-E f curves are hysteretic and nonlinear, and the hysteresis curve width depends on the electric field scan amplitude. Unless the P f-E f relation is known, the field E f strength cannot be solved when the voltage is applied between the gate meal and the semiconductor substrate, and thus P f-E f cannot be obtained after all. In this paper, the method for disclosing the relationships among the polarization peak-to-peak amplitude (2P mm_av), the electric field peak-to-peak amplitude (2E mm_av), and the memory window (E w) in units of the electric field is presented. To get P mm_av versus E mm_av, FeFETs with different ferroelectric-layer thicknesses should be prepared. Knowing such essential physical parameters is helpful and in many cases enough to quantitatively understand the behavior of FeFETs. The method is applied to three groups. The first one consists of SrBi2Ta2O9-based FeFETs. The second and third ones consist of Ca x Sr1-x Bi2Ta2O9-based FeFETs made by two kinds of annealing. The method can clearly differentiate the characters of the three groups. By applying the method, ferroelectric relationships among P mm_av, E mm_av, and E w are well classified in the three groups according to the difference of the material kinds and the annealing conditions. The method also evaluates equivalent oxide thickness (EOT) of a dual layer of a deposited high-k insulator and a thermally-grown SiO2-like interfacial layer (IL). The IL thickness calculated by the method is consistent with cross-sectional image of the FeFETs observed by a transmission electron microscope. The method successfully discloses individual characteristics of the ferroelectric and the insulator layers hidden in the gate stack

  3. A Novel Multimodal Biometrics Recognition Model Based on Stacked ELM and CCA Methods

    Directory of Open Access Journals (Sweden)

    Jucheng Yang

    2018-04-01

    Full Text Available Multimodal biometrics combine a variety of biological features to have a significant impact on identification performance, which is a newly developed trend in biometrics identification technology. This study proposes a novel multimodal biometrics recognition model based on the stacked extreme learning machines (ELMs and canonical correlation analysis (CCA methods. The model, which has a symmetric structure, is found to have high potential for multimodal biometrics. The model works as follows. First, it learns the hidden-layer representation of biological images using extreme learning machines layer by layer. Second, the canonical correlation analysis method is applied to map the representation to a feature space, which is used to reconstruct the multimodal image feature representation. Third, the reconstructed features are used as the input of a classifier for supervised training and output. To verify the validity and efficiency of the method, we adopt it for new hybrid datasets obtained from typical face image datasets and finger-vein image datasets. Our experimental results demonstrate that our model performs better than traditional methods.

  4. Classifier Subset Selection for the Stacked Generalization Method Applied to Emotion Recognition in Speech

    Science.gov (United States)

    Álvarez, Aitor; Sierra, Basilio; Arruti, Andoni; López-Gil, Juan-Miguel; Garay-Vitoria, Nestor

    2015-01-01

    In this paper, a new supervised classification paradigm, called classifier subset selection for stacked generalization (CSS stacking), is presented to deal with speech emotion recognition. The new approach consists of an improvement of a bi-level multi-classifier system known as stacking generalization by means of an integration of an estimation of distribution algorithm (EDA) in the first layer to select the optimal subset from the standard base classifiers. The good performance of the proposed new paradigm was demonstrated over different configurations and datasets. First, several CSS stacking classifiers were constructed on the RekEmozio dataset, using some specific standard base classifiers and a total of 123 spectral, quality and prosodic features computed using in-house feature extraction algorithms. These initial CSS stacking classifiers were compared to other multi-classifier systems and the employed standard classifiers built on the same set of speech features. Then, new CSS stacking classifiers were built on RekEmozio using a different set of both acoustic parameters (extended version of the Geneva Minimalistic Acoustic Parameter Set (eGeMAPS)) and standard classifiers and employing the best meta-classifier of the initial experiments. The performance of these two CSS stacking classifiers was evaluated and compared. Finally, the new paradigm was tested on the well-known Berlin Emotional Speech database. We compared the performance of single, standard stacking and CSS stacking systems using the same parametrization of the second phase. All of the classifications were performed at the categorical level, including the six primary emotions plus the neutral one. PMID:26712757

  5. Methods and instruments for materials testing

    Science.gov (United States)

    Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)

    2011-01-01

    Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.

  6. Astronomical optical interferometry, I: Methods and instrumentation

    Directory of Open Access Journals (Sweden)

    Jankov S.

    2010-01-01

    Full Text Available Previous decade has seen an achievement of large interferometric projects including 8-10m telescopes and 100m class baselines. Modern computer and control technology has enabled the interferometric combination of light from separate telescopes also in the visible and infrared regimes. Imaging with milli-arcsecond (mas resolution and astrometry with micro-arcsecond (µas precision have thus become reality. Here, I review the methods and instrumentation corresponding to the current state in the field of astronomical optical interferometry. First, this review summarizes the development from the pioneering works of Fizeau and Michelson. Next, the fundamental observables are described, followed by the discussion of the basic design principles of modern interferometers. The basic interferometric techniques such as speckle and aperture masking interferometry, aperture synthesis and nulling interferometry are discussed as well. Using the experience of past and existing facilities to illustrate important points, I consider particularly the new generation of large interferometers that has been recently commissioned (most notably, the CHARA, Keck, VLT and LBT Interferometers. Finally, I discuss the longer-term future of optical interferometry, including the possibilities of new large-scale ground-based projects and prospects for space interferometry.

  7. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  8. A simplified technique for polymethyl methacrylate cranioplasty: combined cotton stacking and finger fracture method.

    Science.gov (United States)

    Kung, Woon-Man; Lin, Muh-Shi

    2012-01-01

    Polymethyl methacrylate (PMMA) is one of the most frequently used cranioplasty materials. However, limitations exist with PMMA cranioplasty including longer operative time, greater blood loss and a higher infection rate. To reduce these disadvantages, it is proposed to introduce a new surgical method for PMMA cranioplasty. Retrospective review of nine patients who received nine PMMA implants using combined cotton stacking and finger fracture method from January 2008 to July 2011. The definitive height of skull defect was quantified by computer-based image analysis of computed tomography (CT) scans. Aesthetic outcomes as measured by post-reduction radiographs and cranial index of symmetry (CIS), cranial nerve V and VII function and complications (wound infection, hardware extrusions, meningitis, osteomyelitis and brain abscess) were evaluated. The mean operation time for implant moulding was 24.56 ± 4.6 minutes and 178.0 ± 53 minutes for skin-to-skin. Average blood loss was 169 mL. All post-operative radiographs revealed excellent reduction. The mean CIS score was 95.86 ± 1.36%, indicating excellent symmetry. These results indicate the safety, practicability, excellent cosmesis, craniofacial symmetry and stability of this new surgical technique.

  9. Monitoring Mining Subsidence Using A Combination of Phase-Stacking and Offset-Tracking Methods

    Directory of Open Access Journals (Sweden)

    Hongdong Fan

    2015-07-01

    Full Text Available An approach to study the mechanism of mining-induced subsidence, using a combination of phase-stacking and sub-pixel offset-tracking methods, is reported. In this method, land subsidence with a small deformation gradient was calculated using time-series differential interferometric synthetic aperture radar (D-InSAR data, whereas areas with greater subsidence were calculated by a sub-pixel offset-tracking method. With this approach, time-series data for mining subsidence were derived in Yulin area using 11 TerraSAR-X (TSX scenes from 13 December 2012 to 2 April 2013. The maximum mining subsidence and velocity values were 4.478 m and 40 mm/day, respectively, which were beyond the monitoring capabilities of D-InSAR and advanced InSAR. The results were compared with the GPS field survey data, and the root mean square errors (RMSE of the results in the strike and dip directions were 0.16 m and 0.11 m, respectively. Four important results were obtained from the time-series subsidence in this mining area: (1 the mining-induced subsidence entered the residual deformation stage within about 44 days; (2 the advance angle of influence changed from 75.6° to 80.7°; (3 the prediction parameters of mining subsidence; (4 three-dimensional deformation. This method could be used to predict the occurrence of mining accidents and to help in the restoration of the ecological environment after mining activities have ended.

  10. A new method for the characterisation and quantitative speciation of base metal smelter stack particulates.

    Science.gov (United States)

    Skeaff, James M; Thibault, Yves; Hardy, David J

    2011-06-01

    Base metal smelters may be a source of particulates containing metals of environmental concern released to the atmosphere. Knowledge of the quantitative chemical speciation of particulate releases from base metal smelters will be of value in smelter emission fingerprinting, site-specific risk assessments, predictions of the behaviour of smelter stack particulates released to the environment and in resolving liability issues related to current and historic releases. Accordingly, we have developed an innovative approach comprising bulk chemical analysis, a leaching procedure, X-ray diffraction analysis and scanning electron microscopy/electron probe microanalysis characterisation in a step-wise apportioning procedure to derive the quantitative speciation of particulate samples from the stacks of three copper smelters designated as A, B and C. For the A smelter stack particulates, the major calculated percentages were 29 CuSO(4), 20 ZnSO(4).H(2)O, 13 (Cu(0.94)Zn(0.06))(2)(AsO(4))(OH), 11 PbSO(4) and four As(2)O(3). For the B smelter stack particulates, the primary calculated percentages were 20 ZnSO(4).H(2)O, 20 PbSO(4), 12 CuSO(4) and nine As(2)O(3). Finally, we calculated that the C smelter stack particulates mostly comprised 34 ZnSO(4).H(2)O, 19 (Cu(0.84)Zn(0.16))(AsO(3)OH), 11 PbSO(4), 10 As(2)O(3) and nine Zn(3)(AsO(4))(2). Between 56% and 67% by weight of the smelter stack particulates, including the As, was soluble in water. For these and other operations, the data and approach may be useful in estimating metals partitioning among water, soil and sediment, as well as predictions of the effects of the stack particulates released to the environment.

  11. Surface Imaging Skin Friction Instrument and Method

    Science.gov (United States)

    Brown, James L. (Inventor); Naughton, Jonathan W. (Inventor)

    1999-01-01

    A surface imaging skin friction instrument allowing 2D resolution of spatial image by a 2D Hilbert transform and 2D inverse thin-oil film solver, providing an innovation over prior art single point approaches. Incoherent, monochromatic light source can be used. The invention provides accurate, easy to use, economical measurement of larger regions of surface shear stress in a single test.

  12. Parallel processing and maintaining adequate alignment between instruments and methods.

    Science.gov (United States)

    Calleja, John

    2008-08-01

    Parallel processing of laboratory tests across more than one instrument platform: permits dealing with increasing workloads; but broadens uncertainty of measurement; minimising measurement uncertainty means keeping assay performances continuously aligned. Important questions are: Why is there the need to demonstrate "acceptable alignment" between methods/instruments? What methods/tools can be used to test method/instrument alignment and how adjustments can be made? What is an "acceptable" alignment? How often should alignments be checked and what is the reasoning for this?

  13. A pulse stacking method of particle counting applied to position sensitive detection

    International Nuclear Information System (INIS)

    Basilier, E.

    1976-03-01

    A position sensitive particle counting system is described. A cyclic readout imaging device serves as an intermediate information buffer. Pulses are allowed to stack in the imager at very high counting rates. Imager noise is completely discriminated to provide very wide dynamic range. The system has been applied to a detector using cascaded microchannel plates. Pulse height spread produced by the plates causes some loss of information. The loss is comparable to the input loss of the plates. The improvement in maximum counting rate is several hundred times over previous systems that do not permit pulse stacking. (Auth.)

  14. Purging Musical Instrument Sample Databases Using Automatic Musical Instrument Recognition Methods

    OpenAIRE

    Livshin , Arie; Rodet , Xavier

    2009-01-01

    cote interne IRCAM: Livshin09a; None / None; National audience; Compilation of musical instrument sample databases requires careful elimination of badly recorded samples and validation of sample classification into correct categories. This paper introduces algorithms for automatic removal of bad instrument samples using Automatic Musical Instrument Recognition and Outlier Detection techniques. Best evaluation results on a methodically contaminated sound database are achieved using the introdu...

  15. Method of detecting stacks with leaky fuel elements in liquid-metal-cooled reactor and apparatus for effecting same

    International Nuclear Information System (INIS)

    Aristarkhov, N.N.; Efimov, I.A.; Zaistev, B.I.; Peters, I.G.; Tymosh, B.S.

    1976-01-01

    Described is a method of detecting stacks with leaky fuel elements in a liquid-metal-cooled reactor, consisting in that prior to withdrawing a coolant sample, gas is accumulated in the coolant of the stack being controlled, the reactor being shut down, separated from the sample by means of an inert carrier gas, and the radioactivity of the separated gas is measured. An apparatus for carrying out said method comprises a sampler in the form of a tube parallel to the reactor axis in the hole of a rotating plug and adapted to move along the reactor axis. Made in the top portion of the tube are holes for the introduction of the inert carrier gas and the removal thereof together with the gases evolved from the coolant, while the bottom portion of the tube is provided with a sealing member

  16. Three-dimensional stacked structured ASIC devices and methods of fabrication thereof

    Science.gov (United States)

    Shinde, Subhash L.; Teifel, John; Flores, Richard S.; Jarecki Jr., Robert L.; Bauer, Todd

    2015-11-19

    A 3D stacked sASIC is provided that includes a plurality of 2D reconfigurable structured structured ASIC (sASIC) levels interconnected through hard-wired arrays of 3D vias. The 2D sASIC levels may contain logic, memory, analog functions, and device input/output pad circuitry. During fabrication, these 2D sASIC levels are stacked on top of each other and fused together with 3D metal vias. Such 3D vias may be fabricated as through-silicon vias (TSVs). They may connect to the back-side of the 2D sASIC level, or they may be connected to top metal pads on the front-side of the 2D sASIC level.

  17. Instrument design optimization with computational methods

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Michael H. [Old Dominion Univ., Norfolk, VA (United States)

    2017-08-01

    Using Finite Element Analysis to approximate the solution of differential equations, two different instruments in experimental Hall C at the Thomas Jefferson National Accelerator Facility are analyzed. The time dependence of density uctuations from the liquid hydrogen (LH2) target used in the Qweak experiment (2011-2012) are studied with Computational Fluid Dynamics (CFD) and the simulation results compared to data from the experiment. The 2.5 kW liquid hydrogen target was the highest power LH2 target in the world and the first to be designed with CFD at Jefferson Lab. The first complete magnetic field simulation of the Super High Momentum Spectrometer (SHMS) is presented with a focus on primary electron beam deflection downstream of the target. The SHMS consists of a superconducting horizontal bending magnet (HB) and three superconducting quadrupole magnets. The HB allows particles scattered at an angle of 5:5 deg to the beam line to be steered into the quadrupole magnets which make up the optics of the spectrometer. Without mitigation, remnant fields from the SHMS may steer the unscattered beam outside of the acceptable envelope on the beam dump and limit beam operations at small scattering angles. A solution is proposed using optimal placement of a minimal amount of shielding iron around the beam line.

  18. Improved GLR method to instrument failure detection

    International Nuclear Information System (INIS)

    Jeong, Hak Yeoung; Chang, Soon Heung

    1985-01-01

    The generalized likehood radio(GLR) method performs statistical tests on the innovations sequence of a Kalman-Buchy filter state estimator for system failure detection and its identification. However, the major drawback of the convensional GLR is to hypothesize particular failure type in each case. In this paper, a method to solve this drawback is proposed. The improved GLR method is applied to a PWR pressurizer and gives successful results in detection and identification of any failure. Furthmore, some benefit on the processing time per each cycle of failure detection and its identification can be accompanied. (Author)

  19. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  20. Application of Instrumented Charpy Method in Characterisation of Materials

    OpenAIRE

    Alar, Željko; Mandić, Davor; Dugorepec, Andrija; Sakoman, Matija

    2015-01-01

    Testing of absorbed impact energy according to the Charpy method is carried out to determine the behaviour of a material under the impact load. Instrumented Charpy method allows getting the force displacement curve through the entire test, That curve can be related to force-displacement curve which is obtained by the static tensile test. The purpose of this study was to compare the results of forces obtained by the static tensile test with the forces obtained by the instrumented Charpy method...

  1. Evaluation of two gas-dilution methods for instrument calibration

    Science.gov (United States)

    Evans, A., Jr.

    1977-01-01

    Two gas dilution methods were evaluated for use in the calibration of analytical instruments used in air pollution studies. A dual isotope fluorescence carbon monoxide analyzer was used as the transfer standard. The methods are not new but some modifications are described. The rotary injection gas dilution method was found to be more accurate than the closed loop method. Results by the two methods differed by 5 percent. This could not be accounted for by the random errors in the measurements. The methods avoid the problems associated with pressurized cylinders. Both methods have merit and have found a place in instrument calibration work.

  2. Fast and sensitive method to determine parabens by capillary electrophoresis using automatic reverse electrode polarity stacking mode: application to hair samples.

    Science.gov (United States)

    Sako, Alysson V F; Dolzan, Maressa D; Micke, Gustavo Amadeu

    2015-09-01

    This paper describes a fast and sensitive method for the determination of methyl, ethyl, propyl, and butylparaben in hair samples by capillary electrophoresis using automatic reverse electrode polarity stacking mode. In the proposed method, solutions are injected using the flush command of the analysis software (940 mbar) and the polarity switching is carried out automatically immediately after the sample injection. The advantages compared with conventional stacking methods are the increased analytical frequency, repeatability, and inter-day precision. All analyses were performed in a fused silica capillary (50 cm, 41.5 cm in effective length, 50 μm i.d.), and the background electrolyte was composed of 20 mmol L(-1) sodium tetraborate in 10 % of methanol, pH 9.3. For the reverse polarity, -25 kV/35 s was applied followed by application of +30 kV for the electrophoretic run. Temperature was set at 20 °C, and all analytes were monitored at 297 nm. The method showed acceptable linearity (r (2) > 0.997) in the studied range of 0.1-5.0 mg L(-1), limits of detection below 0.017 mg L(-1), and inter-day, intra-day, and instrumental precision better than 6.2, 3.6, and 4.6 %, respectively. Considering parabens is widely used as a preservative in many products and the reported possibility of damage to the hair and also to human health caused by these compounds, the proposed method was applied to evaluate the adsorption of parabens in hair samples. The results indicate that there is a greater adsorption of methylparaben compared to the other parabens tested and also dyed hairs had a greater adsorption capacity for parabens than natural hairs.

  3. Turbidity threshold sampling: Methods and instrumentation

    Science.gov (United States)

    Rand Eads; Jack Lewis

    2001-01-01

    Traditional methods for determining the frequency of suspended sediment sample collection often rely on measurements, such as water discharge, that are not well correlated to sediment concentration. Stream power is generally not a good predictor of sediment concentration for rivers that transport the bulk of their load as fines, due to the highly variable routing of...

  4. Methods and instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Mandelkern, M.A.; Phelps, M.E.

    1988-01-01

    This paper reports on positron emission tomography (PET), a technique for the noninvasive measurement of local tissue concentrations of injected radioactive tracers. Tracer kinetics techniques can be applied to this information to quantify physiologic function in human tissue. In the tracer method, a pharmaceutical is labeled by a radioactive atom. When introduced into the subject that molecule follows a physiologic pathway. The space- and time-dependent distribution of the radionuclide is obtained via an imaging technique. If the radiopharmaceutical is sufficiently analogous to a natural substrate or other substance of interest, a quantitative image can be translated into a physiologic measurement

  5. A method to estimate emission rates from industrial stacks based on neural networks.

    Science.gov (United States)

    Olcese, Luis E; Toselli, Beatriz M

    2004-11-01

    This paper presents a technique based on artificial neural networks (ANN) to estimate pollutant rates of emission from industrial stacks, on the basis of pollutant concentrations measured on the ground. The ANN is trained on data generated by the ISCST3 model, widely accepted for evaluation of dispersion of primary pollutants as a part of an environmental impact study. Simulations using theoretical values and comparison with field data are done, obtaining good results in both cases at predicting emission rates. The application of this technique would allow the local environment authority to control emissions from industrial plants without need of performing direct measurements inside the plant. copyright 2004 Elsevier Ltd.

  6. Fault Localization Method by Partitioning Memory Using Memory Map and the Stack for Automotive ECU Software Testing

    Directory of Open Access Journals (Sweden)

    Kwanhyo Kim

    2016-09-01

    Full Text Available Recently, the usage of the automotive Electronic Control Unit (ECU and its software in cars is increasing. Therefore, as the functional complexity of such software increases, so does the likelihood of software-related faults. Therefore, it is important to ensure the reliability of ECU software in order to ensure automobile safety. For this reason, systematic testing methods are required that can guarantee software quality. However, it is difficult to locate a fault during testing with the current ECU development system because a tester performs the black-box testing using a Hardware-in-the-Loop (HiL simulator. Consequently, developers consume a large amount of money and time for debugging because they perform debugging without any information about the location of the fault. In this paper, we propose a method for localizing the fault utilizing memory information during black-box testing. This is likely to be of use to developers who debug automotive software. In order to observe whether symbols stored in the memory have been updated, the memory is partitioned by a memory map and the stack, thus the fault candidate region is reduced. A memory map method has the advantage of being able to finely partition the memory, and the stack method can partition the memory without a memory map. We validated these methods by applying these to HiL testing of the ECU for a body control system. The preliminary results indicate that a memory map and the stack reduce the possible fault locations to 22% and 19% of the updated memory, respectively.

  7. Method to deterministically study photonic nanostructures in different experimental instruments

    NARCIS (Netherlands)

    Husken, B.H.; Woldering, L.A.; Blum, Christian; Tjerkstra, R.W.; Vos, Willem L.

    2009-01-01

    We describe an experimental method to recover a single, deterministically fabricated nanostructure in various experimental instruments without the use of artificially fabricated markers, with the aim to study photonic structures. Therefore, a detailed map of the spatial surroundings of the

  8. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  9. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  10. Astronomical Optical Interferometry. I. Methods and Instrumentation

    Directory of Open Access Journals (Sweden)

    Jankov, S.

    2010-12-01

    Full Text Available Previous decade has seen an achievement of large interferometricprojects including 8-10m telescopes and 100m class baselines. Modern computerand control technology has enabled the interferometric combination of lightfrom separate telescopes also in the visible and infrared regimes. Imagingwith milli-arcsecond (mas resolution and astrometry with micro-arcsecond($mu$as precision have thus become reality. Here, I review the methods andinstrumentation corresponding to the current state in the field ofastronomical optical interferometry. First, this review summarizes thedevelopment from the pioneering works of Fizeau and Michelson. Next, thefundamental observables are described, followed by the discussion of the basicdesign principles of modern interferometers. The basic interferometrictechniques such as speckle and aperture masking interferometry, aperture synthesisand nulling interferometry are disscused as well. Using the experience ofpast and existing facilities to illustrate important points, I considerparticularly the new generation of large interferometers that has beenrecently commissioned (most notably, the CHARA, Keck, VLT and LBTInterferometers. Finally, I discuss the longer-term future of opticalinterferometry, including the possibilities of new large-scale ground-based projects and prospects for space interferometry.

  11. Methods and Instruments for Fast Neutron Detection

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Reeder, Paul L.; Cooper, Matthew W.; McCormick, Kathleen R.; Peurrung, Anthony J.; Warren, Glen A.

    2005-05-01

    Pacific Northwest National Laboratory evaluated the performance of a large-area (~0.7 m2) plastic scintillator time-of-flight (TOF) sensor for direct detection of fast neutrons. This type of sensor is a readily area-scalable technology that provides broad-area geometrical coverage at a reasonably low cost. It can yield intrinsic detection efficiencies that compare favorably with moderator-based detection methods. The timing resolution achievable should permit substantially more precise time windowing of return neutron flux than would otherwise be possible with moderated detectors. The energy-deposition threshold imposed on each scintillator contributing to the event-definition trigger in a TOF system can be set to blind the sensor to direct emission from the neutron generator. The primary technical challenge addressed in the project was to understand the capabilities of a neutron TOF sensor in the limit of large scintillator area and small scintillator separation, a size regime in which the neutral particle’s flight path between the two scintillators is not tightly constrained.

  12. Algebraic stacks

    Indian Academy of Sciences (India)

    generally, any fiber product) is not uniquely defined: it is only defined up to unique isomorphism. ..... Fiber product. Given two morphisms f1 : F1 ! G, f2 : F2 ! G, we define a new stack. F1 آG F2 (with projections to F1 and F2) as follows. The objects are triples ًX1; X2; ق ..... In fact, any Artin stack F can be defined in this fashion.

  13. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  14. Method of applying a mirror reflecting layer to instrument parts

    Science.gov (United States)

    Alkhanov, L. G.; Danilova, I. A.; Delektorskiy, G. V.

    1974-01-01

    A method follows for applying a mirror reflecting layer to the surfaces of parts, instruments, apparatus, and so on. A brief analysis is presented of the existing methods of obtaining the mirror surface and the advantages of the new method of obtaining the mirror surface by polymer casting mold are indicated.

  15. An Examination of Secondary Wind Instrument Methods Courses

    Science.gov (United States)

    Wagoner, Cynthia L.; Juchniewicz, Jay

    2017-01-01

    The purpose of this study was to investigate current secondary woodwind, brass, and combined wind instrument methods courses for preservice music teachers across the United States. Two-hundred eleven (N = 211) wind methods course instructors from National Association of Schools of Music-accredited institutions completed an online survey that…

  16. A Mixed Methods Portrait of Urban Instrumental Music Teaching

    Science.gov (United States)

    Fitzpatrick, Kate R.

    2011-01-01

    The purpose of this mixed methods study was to learn about the ways that instrumental music teachers in Chicago navigated the urban landscape. The design of the study most closely resembles Creswell and Plano Clark's (2007) two-part Triangulation Convergence Mixed Methods Design, with the addition of an initial exploratory focus group component.…

  17. Application of Instrumented Charpy Method in Characterisation of Materials

    Directory of Open Access Journals (Sweden)

    Željko Alar

    2015-07-01

    Full Text Available Testing of absorbed impact energy according to the Charpy method is carried out to determine the behaviour of a material under the impact load. Instrumented Charpy method allows getting the force displacement curve through the entire test, That curve can be related to force-displacement curve which is obtained by the static tensile test. The purpose of this study was to compare the results of forces obtained by the static tensile test with the forces obtained by the instrumented Charpy method. Experimental part of the work contains testing of the mechanical properties of S275J0 steel by the static tensile test and Impact test on instrumented Charpy pendulum.

  18. Interface reactions at TiN/HfSiON gate stacks: Dependence on the electrode structure and deposition method

    Directory of Open Access Journals (Sweden)

    Shiniti Yoshida et al

    2007-01-01

    Full Text Available We systematically investigated intrinsic and extrinsic thermal reactions at TiN/HfSiON gate stacks. The formation of an ultrathin TiO2 interlayer was found to be an intrinsic reaction at the metal/insulator interface, but growth of SiO2 underlayers between HfSiON and Si substrates, which determines the electrical thickness of metal-oxide-semiconductor (MOS devices, depends on the structure and deposition method of the gate electrodes. Physical vapor deposition (PVD grown TiN electrodes covered with W overlayers exhibited excellent thermal stability at up to 1000 °C. Formation of ultrathin TiO2 interlayers reduced gate leakage current (Ig, and growth of the oxide underlayer was suppressed by less than a few angstroms even for 1000 °C annealing. In contrast, we found that halogen impurities within CVD-grown metal electrodes enhance interface SiO2 growth, resulting in deterioration of equivalent oxide thickness (EOT versus Ig characteristics of the gate stacks.

  19. Algebraic stacks

    Indian Academy of Sciences (India)

    truct the 'moduli stack', that captures all the information that we would like in a fine moduli space. ..... the fine moduli space), it has the property that for any family W of vector bundles (i.e. W is a vector bundle over B ...... the etale topology is finer: V is a 'small enough open subset' because the square root can be defined on it.

  20. Methods and instruments for ensemble particle sizing by light scattering

    International Nuclear Information System (INIS)

    Bayvel, L.P.

    1986-01-01

    The instruments for ensemble analysis are based on two methods. The first method involves the approximation of the relationship between intensity scattered or transmitted by a particle and its size. This method enables one to compute the number or volume particle size distributions by finding a solution to a Fredholm integral if the scattering patern is measured. An alternative method is by expressing the angle dependent intensity of scattered light, the particle size distribution and the scattering coefficients for individual particles in a matrix equation. This method exploits the Mie scattering theory. All the instruments are based on the Fraunhofer diffraction theory. The solid particle is normally illuminated by a beam from a low-power helium-neon laser. A variation of detector assemblies is used to detect the scattered light. Instruments which are used for particle size measurements measure the extinction coefficients for different wavelenghts and scattering at 90 degrees by recording light intensity in two orthogonal planes of polarisation for each of three wavelenghts. Correction factors to take multiple scattering in account are also discussed

  1. Exhaled breath analysis: physical methods, instruments, and medical diagnostics

    International Nuclear Information System (INIS)

    Vaks, V L; Domracheva, E G; Sobakinskaya, E A; Chernyaeva, M B

    2014-01-01

    This paper reviews the analysis of exhaled breath, a rapidly growing field in noninvasive medical diagnostics that lies at the intersection of physics, chemistry, and medicine. Current data are presented on gas markers in human breath and their relation to human diseases. Various physical methods for breath analysis are described. It is shown how measurement precision and data volume requirements have stimulated technological developments and identified the problems that have to be solved to put this method into clinical practice. (instruments and methods of investigation)

  2. Standard test method for instrumented impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard establishes the requirements for performing instrumented Charpy V-Notch (CVN) and instrumented Miniaturized Charpy V-Notch (MCVN) impact tests on metallic materials. This method, which is based on experience developed testing steels, provides further information (in addition to the total absorbed energy) on the fracture behavior of the tested materials. Minimum requirements are given for measurement and recording equipment such that similar sensitivity and comparable total absorbed energy measurements to those obtained in Test Methods E 23 and E 2248 are achieved. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Hybrid Instruments and the Indirect Credit Method - Does it work?

    OpenAIRE

    Wiedermann-Ondrej, Nadine

    2007-01-01

    This paper analyses the possibility of double non-taxation of hybrid instruments in cross border transactions where the country of the investor has implemented the indirect credit method for mitigation or elimination of double taxation. From an isolated perspective a double non-taxation cannot be obtained because typically no taxes are paid in the foreign country due to the classification as debt and therefore even in the case of a classification as a dividend in the country of the investor n...

  4. A spectroscopic method for calibration of solar extreme ultraviolet instrumentation

    Science.gov (United States)

    Neupert, W. M.; Kastner, S. O.

    1983-01-01

    A method of calibrating solar extreme ultraviolet spectrographs in space using coronal emission lines of known relative intensity is presented and demonstrated. This approach is useful for recalibrating orbiting instruments that may be subject to degradation during extended periods of operation. The calibration results are insensitive to the physical distribution of emitting plasma in any likely solar coronal source. It is suggested that this technique may be useful for calibration of spectrographs used in the study of laboratory plasmas.

  5. The Determination of Total Nitrogen Oxides in Stack Gases. Phenoldisulfonic Acid Method.

    Science.gov (United States)

    Thorpe, Charles J. D.

    The well known Saltzman method for oxides of nitrogen is intended for the determination of these constituents in the ambient atmosphere in the range of a few parts per billion to about 5ppm. However, when sulfur dioxide is present in the gas to be sampled and/or the concentration range of the oxides of nitrogen is from five to several thousand…

  6. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  7. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  8. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  9. Pressurized electrolysis stack with thermal expansion capability

    Science.gov (United States)

    Bourgeois, Richard Scott

    2015-07-14

    The present techniques provide systems and methods for mounting an electrolyzer stack in an outer shell so as to allow for differential thermal expansion of the electrolyzer stack and shell. Generally, an electrolyzer stack may be formed from a material with a high coefficient of thermal expansion, while the shell may be formed from a material having a lower coefficient of thermal expansion. The differences between the coefficients of thermal expansion may lead to damage to the electrolyzer stack as the shell may restrain the thermal expansion of the electrolyzer stack. To allow for the differences in thermal expansion, the electrolyzer stack may be mounted within the shell leaving a space between the electrolyzer stack and shell. The space between the electrolyzer stack and the shell may be filled with a non-conductive fluid to further equalize pressure inside and outside of the electrolyzer stack.

  10. Standoff Stack Emissions Monitoring Using Short Range Lidar

    Science.gov (United States)

    Gravel, Jean-Francois Y.; Babin, Francois; Allard, Martin

    2016-06-01

    There are well documented methods for stack emissions monitoring. These are all based on stack sampling through sampling ports in well defined conditions. Once sampled, the molecules are quantified in instruments that often use optical techniques. Unfortunately sampling ports are not found on all stacks/ducts or the use of the sampling ports cannot be planned efficiently because of operational constraints or the emissions monitoring equipment cannot be driven to a remote stack/duct. Emissions monitoring using many of the same optical techniques, but at a standoff distance, through the atmosphere, using short range high spatial resolution lidar techniques was thus attempted. Standoff absorption and Raman will be discussed and results from a field campaign will be presented along with short descriptions of the apparatus. In the first phase of these tests, the molecules that were targeted were NO and O2. Spatially resolved optical measurements allow for standoff identification and quantification of molecules, much like the standardized methods, except for the fact that it is not done in the stack, but in the plume formed by the emissions from the stack. The pros and cons will also be discussed, and in particular the problem of mass emission estimates that require the knowledge of the flow rate and the distribution of molecular concentration in the plane of measurement.

  11. Standoff Stack Emissions Monitoring Using Short Range Lidar

    Directory of Open Access Journals (Sweden)

    Gravel Jean-Francois Y.

    2016-01-01

    Full Text Available There are well documented methods for stack emissions monitoring. These are all based on stack sampling through sampling ports in well defined conditions. Once sampled, the molecules are quantified in instruments that often use optical techniques. Unfortunately sampling ports are not found on all stacks/ducts or the use of the sampling ports cannot be planned efficiently because of operational constraints or the emissions monitoring equipment cannot be driven to a remote stack/duct. Emissions monitoring using many of the same optical techniques, but at a standoff distance, through the atmosphere, using short range high spatial resolution lidar techniques was thus attempted. Standoff absorption and Raman will be discussed and results from a field campaign will be presented along with short descriptions of the apparatus. In the first phase of these tests, the molecules that were targeted were NO and O2. Spatially resolved optical measurements allow for standoff identification and quantification of molecules, much like the standardized methods, except for the fact that it is not done in the stack, but in the plume formed by the emissions from the stack. The pros and cons will also be discussed, and in particular the problem of mass emission estimates that require the knowledge of the flow rate and the distribution of molecular concentration in the plane of measurement.

  12. A hybrid MBE-based growth method for large-area synthesis of stacked hexagonal boron nitride/graphene heterostructures

    Science.gov (United States)

    Wofford, Joseph M.; Nakhaie, Siamak; Krause, Thilo; Liu, Xianjie; Ramsteiner, Manfred; Hanke, Michael; Riechert, Henning; J. Lopes, J. Marcelo

    2017-01-01

    Van der Waals heterostructures combining hexagonal boron nitride (h-BN) and graphene offer many potential advantages, but remain difficult to produce as continuous films over large areas. In particular, the growth of h-BN on graphene has proven to be challenging due to the inertness of the graphene surface. Here we exploit a scalable molecular beam epitaxy based method to allow both the h-BN and graphene to form in a stacked heterostructure in the favorable growth environment provided by a Ni(111) substrate. This involves first saturating a Ni film on MgO(111) with C, growing h-BN on the exposed metal surface, and precipitating the C back to the h-BN/Ni interface to form graphene. The resulting laterally continuous heterostructure is composed of a top layer of few-layer thick h-BN on an intermediate few-layer thick graphene, lying on top of Ni/MgO(111). Examinations by synchrotron-based grazing incidence diffraction, X-ray photoemission spectroscopy, and UV-Raman spectroscopy reveal that while the h-BN is relaxed, the lattice constant of graphene is significantly reduced, likely due to nitrogen doping. These results illustrate a different pathway for the production of h-BN/graphene heterostructures, and open a new perspective for the large-area preparation of heterosystems combining graphene and other 2D or 3D materials. PMID:28240323

  13. Extending the frontiers of mass spectrometric instrumentation and methods

    Energy Technology Data Exchange (ETDEWEB)

    Schieffer, Gregg Martin [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imaging plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a

  14. Inter-instrumental method transfer of chiral capillary electrophoretic methods using robustness test information.

    Science.gov (United States)

    De Cock, Bart; Borsuk, Agnieszka; Dejaegher, Bieke; Stiens, Johan; Mangelings, Debby; Vander Heyden, Yvan

    2014-08-01

    Capillary electrophoresis (CE) is an electrodriven separation technique that is often used for the separation of chiral molecules. Advantages of CE are its flexibility, low cost and efficiency. On the other hand, the precision and transfer of CE methods are well-known problems of the technique. Reasons for the more complicated method transfer are the more diverse instrumental differences, such as total capillary lengths and capillary cooling systems; and the higher response variability of CE methods compared to other techniques, such as liquid chromatography (HPLC). Therefore, a larger systematic change in peak resolutions, migration times and peak areas, with a loss of separation and efficiency may be seen when a CE method is transferred to another laboratory or another type of instrument. A swift and successful method transfer is required because development and routine use of analytical methods are usually not performed in the same laboratory and/or on the same type of equipment. The aim of our study was to develop transfer rules to facilitate CE method transfers between different laboratories and instruments. In our case study, three β-blockers were chirally separated and inter-instrumental transfers were performed. The first step of our study was to optimise the precision of the chiral CE method. Next, a robustness test was performed to identify the instrumental and experimental parameters that were most influencing the considered responses. The precision- and the robustness study results were used to adapt instrumental and/or method settings to improve the transfer between different instruments. Finally, the comparison of adapted and non-adapted transfers allowed deriving some rules to facilitate CE method transfers. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  16. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  17. Automated Aqueous Sample Concentration Methods for in situ Astrobiological Instrumentation

    Science.gov (United States)

    Aubrey, A. D.; Grunthaner, F. J.

    2009-12-01

    The era of wet chemical experiments for in situ planetary science investigations is upon us, as evidenced by recent results from the surface of Mars by Phoenix’s microscopy, electrochemistry, and conductivity analyzer, MECA [1]. Studies suggest that traditional thermal volatilization methods for planetary science in situ investigations induce organic degradation during sample processing [2], an effect that is enhanced in the presence of oxidants [3]. Recent developments have trended towards adaptation of non-destructive aqueous extraction and analytical methods for future astrobiological instrumentation. Wet chemical extraction techniques under investigation include subcritical water extraction, SCWE [4], aqueous microwave assisted extraction, MAE, and organic solvent extraction [5]. Similarly, development of miniaturized analytical space flight instruments that require aqueous extracts include microfluidic capillary electrophoresis chips, μCE [6], liquid-chromatography mass-spectrometrometers, LC-MS [7], and life marker chips, LMC [8]. If organics are present on the surface of Mars, they are expected to be present at extremely low concentrations (parts-per-billion), orders of magnitude below the sensitivities of most flight instrument technologies. Therefore, it becomes necessary to develop and integrate concentration mechanisms for in situ sample processing before delivery to analytical flight instrumentation. We present preliminary results of automated solid-phase-extraction (SPE) sample purification and concentration methods for the treatment of highly saline aqueous soil extracts. These methods take advantage of the affinity of low molecular weight organic compounds with natural and synthetic scavenger materials. These interactions allow for the separation of target organic analytes from unfavorable background species (i.e. salts) during inline treatment, and a clever method for selective desorption is utilized to obtain concentrated solutions on the order

  18. New methods of magnet-based instrumentation for NOTES.

    Science.gov (United States)

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  19. Operating state distinction and operation control methods of the fuel cell stack; Nenryo denchi sutakku no unten jotai hanbetsu hoho oyobi unten seigyo hoho

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, M.; Nakajima, H.; Shiraishi, K. [Equosu Resarch Co. Ltd., Tokyo (Japan)

    1997-09-19

    In the operation of the fuel cell stack, output decrease is caused by surplus or deficient water content in part or whole of the fuel cell stack. The purpose of the invention is to provide operating state distinction and operation control methods, whereby the output abnormality is discovered in the early stage, and is quickly adjusted to the normal state. In accordance with the invention, time course voltage patterns of the cell block, composed of one or plural unit cells in the fuel cell stack that has solid oxide films as electrolytes, are classified by various operation conditions of the fuel cell, and stored in the memory in advance. Time course voltage patterns are measured by one unit cell or by the cell block; operation conditions are judged, compared and calculated while the measured time course voltage patterns and the patterns in the memory are compared; proper setting of operation conditions is selected; and command for adjusting to the setting is delivered to the unit cell or cell block in the fuel cell stack. 6 figs.

  20. Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-12-31

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs.

  1. Preparation and characterization of porphyrin-polythiophene stacked films as prepared by electrochemical method under stirring condition

    International Nuclear Information System (INIS)

    Sugawa, Kosuke; Akiyama, Tsuyoshi; Yamada, Sunao

    2008-01-01

    Porphyrin-polythiophene (pTh) stacked films consisting of meso-tetrathienylporphyrin (TThP) and bithiophene (BiTh) were prepared on transparent indium-tin-oxide (ITO) electrodes by sequential electrochemical scanning of applied potential between 0 and + 2 V vs Ag wire in the electrolyte solution of BiTh and TThP under stirring condition. First, the pTh films were prepared by electrochemical polymerization and then TThP was incorporated into the as-prepared pTh film by subsequent electrochemical scanning as described above in the TThP solution. The operation of solution stirring during electrochemical scanning achieved the formation of robust stacked films. UV/Vis and fluorescence spectra confirmed that the amount of TThP moiety increased with increasing the number of electrochemical scanning cycles in the TThP solution. In order to evaluate the incorporation profile of TThP, surface analyses and depth profiles of stacked films were carried out by XPS spectroscopy. The results suggested that all films formed porphyrin-polythiophene stacked structure precisely, and that TThP was exclusively incorporated around the outermost region of the pTh film

  2. Experimental and numerical investigations of oscillations in extracted material parameters for finite Bragg stacks using the NRW method

    DEFF Research Database (Denmark)

    Clausen, Niels Christian Jerichau; Arslanagic, Samel; Breinbjerg, Olav

    2012-01-01

    A 1D dielectric finite Bragg stack situated in a rectangular waveguide and illuminated by the fundamental TE10 mode is examined analytically, numerically, and experimentally. Calculated as well as measured scattering parameters are used to extract the effective/equivalent material parameters for ...

  3. Processing of CdTe thin films by the stacked elemental layer method. Compound formation and physical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, L.R. [Departamento de Engenharia, Macanica e de Materiais, Instituto Militar de Engenharia, Praca General Tiburcio, 80, Urca, 22290-270 RJ Rio de Janeiro (Brazil); Matson, R. [National Renewable Energy Laboratory, 1617 Cole Boulevard, 80401 Golden, CO (United States); De Avillez, R.R. [Pontificia Universidade Catolica, Rua Marques de Sao Vicente, 225, Gavea, 22543-900 RJ Rio de Janeiro (Brazil)

    2001-01-01

    Cadmium telluride (CdTe) thin films have been deposited using the stacked elemental layer (SEL) technique. This process consists of sequentially depositing tellurium and cadmium layers and then annealing the stacks in order to synthesize the compound. The films were characterized using X-ray diffraction (XRD), optical transmittance and reflectance, scanning electron microscopy (SEM) and atomic force microscopy (AFM). The evolution of the thin film reaction and compound formation were studied using X-ray data. The results show that the growth is diffusion-controlled and the activation energy is (82{+-}2) kJ/mol. The effect of the conventional post-synthesis CdCl{sub 2} heat treatment on the physical properties of the films produced is also reported.

  4. Congener-specific determination of ultratrace levels of chlorinated and brominated polycyclic aromatic hydrocarbons in atmosphere and industrial stack gas by isotopic dilution gas chromatography/high resolution mass spectrometry method.

    Science.gov (United States)

    Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang

    2017-08-04

    Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.

    Science.gov (United States)

    Miyake, Yuichi; Tokumura, Masahiro; Iwazaki, Yuta; Wang, Qi; Amagai, Takashi; Horii, Yuichi; Otsuka, Hideyuki; Tanikawa, Noboru; Kobayashi, Takeshi; Oguchi, Masahiro

    2017-06-16

    An ion chromatography with post-column derivatization with 1,5-diphenylcarbazide (IC-DPC) analytical method was modified to enable measurement of trace-level hexavalent chromium (Cr(VI)) in air. One of the difficulties in determining trace levels of Cr(VI) in air with conventional IC-DPC methods is co-elution of the solvent and ion peaks due to high concentrations of ionic compounds in the extract. However, by using gradient elution rather than isocratic elution we were able to fully resolve the Cr(VI) ion peak from the solvent peak without the need for diluting the extract, which would have reduced the minimum quantifiable level of the method. With this method, we were able to detect Cr(VI) in air at concentrations of 5.3ng/m 3 (assuming a sampling volume of 1m 3 and a final solution volume of 10mL). Recovery tests at three different concentrations of Cr(VI) (50, 250, 1000ng) were performed with or without fly ash; recovery rates at all the concentrations of Cr(VI), with or without fly ash, ranged from 68% to 110% (mean±relative standard deviation, 96%±11%), and there were no differences in recovery rates with respect to the presence or absence of fly ash. Finally, we used the developed method to determine the concentration of Cr(VI) in stack gases collected from eight industrial waste incinerators located in Japan. The concentration of Cr(VI) in the stack gases ranged from below the method quantification limit to 3100ng/m 3 . The highest concentrations of Cr(VI) detected in the stack gases were two to three orders of magnitude higher than that in ambient air in Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Instrumental performance of an etude after three methods of practice.

    Science.gov (United States)

    Vanden Ark, S

    1997-12-01

    For 80 fifth-grade students three practice conditions (mental, mental with physical simulation, and physical with singing) produced significant mean differences in instrumental performance of an etude. No significant differences were found for traditional, physical practice.

  7. METHODS FOR DESCRIPTION OF EDUCATION AND SCIENTIFIC SERVICES IN INFORMATION AND EDUCATION ON THE BASIS OF INTEROPERABILITY STACK EIF

    Directory of Open Access Journals (Sweden)

    Ekaterina V. Pavlova

    2015-01-01

    Full Text Available The article deals with methodology for description of scientifi c and educational services in education and information on the basis of interoperability stack EIF (European Interoperability Framework. The passage describes operation factors to depict services on every level of the methodology, tools used to describe the services and the content. We also provide the link between methodology of description with the life span of the service. The article presents an example of service description according to the methodology considering the current education and professional standards, ITIL recommendations, ontology on the OWL basis and WSDL-description. 

  8. Spectrometric methods used in the calibration of radiodiagnostic measuring instruments

    Energy Technology Data Exchange (ETDEWEB)

    De Vries, W. [Rijksuniversiteit Utrecht (Netherlands)

    1995-12-01

    Recently a set of parameters for checking the quality of radiation for use in diagnostic radiology was established at the calibration facility of Nederlands Meetinstituut (NMI). The establishment of the radiation quality required re-evaluation of the correction factors for the primary air-kerma standards. Free-air ionisation chambers require several correction factors to measure air-kerma according to its definition. These correction factors were calculated for the NMi free-air chamber by Monte Carlo simulations for monoenergetic photons in the energy range from 10 keV to 320 keV. The actual correction factors follow from weighting these mono-energetic correction factors with the air-kerma spectrum of the photon beam. This paper describes the determination of the photon spectra of the X-ray qualities used for the calibration of dosimetric instruments used in radiodiagnostics. The detector used for these measurements is a planar HPGe-detector, placed in the direct beam of the X-ray machine. To convert the measured pulse height spectrum to the actual photon spectrum corrections must be made for fluorescent photon escape, single and multiple compton scattering inside the detector, and detector efficiency. From the calculated photon spectra a number of parameters of the X-ray beam can be calculated. The calculated first and second half value layer in aluminum and copper are compared with the measured values of these parameters to validate the method of spectrum reconstruction. Moreover the spectrum measurements offer the possibility to calibrate the X-ray generator in terms of maximum high voltage. The maximum photon energy in the spectrum is used as a standard for calibration of kVp-meters.

  9. Instruments and methods to search for extraterrestrial life

    Science.gov (United States)

    Hoover, Richard B.

    2015-09-01

    Is Life restricted to the Planet Earth? or Does life exist elsewhere in the Cosmos? The existence of extraterrestrial life is the fundamental question of Astrobiology. Detecting evidence for living organisms beyond our planet is even more difficult than finding fossilized remains of ancient organisms. Microbiological investigations during the past century have established the fundamental physical and chemical requirements and limits for life on Earth. It is now known that life requires only water, a source of energy, and a small suite of biogenic elements under a surprisingly wide range of environmental conditions. The discovery that microbial extremophiles live and grow over a very broad span of temperature, pH, salinity, pressure and radiation levels has greatly enhanced the possibility that life may be present on many bodies of our Solar System. Recent discoveries by Space Missions and Rovers have invalidated many long held paradigms regarding the distribution of water, organic chemicals and the possibility of life elsewhere in the Cosmos. This paper considers the discovery of water, ice and organics on distant planets, moons and comets and evidence for fossil organisms on Mars and in SNC and carbonaceous meteorites. Instruments and methods are considered for spectroscopy and fluorescence of biomolecules (e.g., photosynthetic pigments) for remote detection of conclusive evidence for extraterrestrial life. Optical Video Microscopy is discussed as a direct means for detecting extraterrestrial life using small visible light/UV video microscopes, with ample magnification to record motile bacteria and other living organisms in samples collected by Rovers or Landers. Locomotion of living cells of bacteria and other microbes requires great expenditure of energy and motile cells can be distinguished by video microscopy from the physico-chemical movements (by Brownian Motion, Diffusion or Current Drift) of dead cells, dust particles and abiotic mineral grains.

  10. Development of a method to measure the concentration of 14C in the stack air of nuclear power plants by accelerator mass spectrometry (AMS)

    International Nuclear Information System (INIS)

    Stenstroem, K.; Erlandsson, B.; Hellborg, R.; Haakansson, K.; Wiebert, A.; Skog, G.

    1993-04-01

    C-14, a pure low-energetic beta-emitter, is produced through various nuclear reactions in nuclear power plants. Some of this C-14 is air-borne and is transported via the ventilation system through the stack of the power station and is integrated in living matter in the surroundings of the plant. The long half-life of the isotope (T1/2=5730 years) and the biological importance of carbon may lead to a not negligible contribution of the radiation dose for those living in the neighbourhood of nuclear power plants. C-14 has earlier been measured radiometrically with mainly two different methods, using proportional counters or liquid scintillators. In this report a new method is described, using an accelerator based technique. accelerator mass spectrometry (AMS). This technique has at least three advantages over the radiometrical methods. It requires only a few litres of gas per sample, which is 100-1000 times less compared to the radiometrical methods. It is insensitive to the beta and gamma rays from other radioactive isotopes in the stack air. The measuring time with AMS, about 20 minutes per sample, is considerably shorter compared to the radiometrical methods, which demand several hours per sample. The integrity of the AMS method is high and it might be convenient for regulatory supervision. (22 refs.)

  11. Multiple Segmentation of Image Stacks

    DEFF Research Database (Denmark)

    Smets, Jonathan; Jaeger, Manfred

    2014-01-01

    We propose a method for the simultaneous construction of multiple image segmentations by combining a recently proposed “convolution of mixtures of Gaussians” model with a multi-layer hidden Markov random field structure. The resulting method constructs for a single image several, alternative...... segmentations that capture different structural elements of the image. We also apply the method to collections of images with identical pixel dimensions, which we call image stacks. Here it turns out that the method is able to both identify groups of similar images in the stack, and to provide segmentations...

  12. GMI Instrument Spin Balance Method, Optimization, Calibration, and Test

    Science.gov (United States)

    Ayari, Laoucet; Kubitschek, Michael; Ashton, Gunnar; Johnston, Steve; Debevec, Dave; Newell, David; Pellicciotti, Joseph

    2014-01-01

    The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3 year mission life. Therefore, GMI must be very precisely balanced about the spin axis and CG to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

  13. Métodos simplificados para o problema de minimização de pilhas abertas Simplified methods for the minimization of open stacks problem

    Directory of Open Access Journals (Sweden)

    Marco Antonio Moreira de Carvalho

    2011-01-01

    Full Text Available Este trabalho apresenta dois métodos para a solução do Problema de Minimização de Pilhas Abertas (ou MOSP, de Minimization of Open Stacks Problem, um problema de sequenciamento de padrões oriundo do contexto de produção de peças, cuja aplicação industrial é direta. O primeiro é relativo a uma heurística baseada em teoria de grafos e critérios gulosos, enquanto o segundo é relativo a um método de programação dinâmica. Os resultados do experimento realizado comprovam a eficácia das simplificações propostas quando comparadas com os métodos da literatura.This paper presents two methods for solving the minimization of open stack problem (MOSP, a pattern sequencing problem found in production systems with direct industrial application. The first method refers to a heuristic based on graph theory and greedy criteria, while the second refers to the dynamic programming method. The results show the effectiveness of the proposed simplifications compared to the methods reported in the literature.

  14. An unsupervised machine learning method for delineating stratum corneum in reflectance confocal microscopy stacks of human skin in vivo

    Science.gov (United States)

    Bozkurt, Alican; Kose, Kivanc; Fox, Christi A.; Dy, Jennifer; Brooks, Dana H.; Rajadhyaksha, Milind

    2016-02-01

    Study of the stratum corneum (SC) in human skin is important for research in barrier structure and function, drug delivery, and water permeability of skin. The optical sectioning and high resolution of reflectance confocal microscopy (RCM) allows visual examination of SC non-invasively. Here, we present an unsupervised segmentation algorithm that can automatically delineate thickness of the SC in RCM images of human skin in-vivo. We mimic clinicians visual process by applying complex wavelet transform over non-overlapping local regions of size 16 x 16 μm called tiles, and analyze the textural changes in between consecutive tiles in axial (depth) direction. We use dual-tree complex wavelet transform to represent textural structures in each tile. This transform is almost shift-invariant, and directionally selective, which makes it highly efficient in texture representation. Using DT-CWT, we decompose each tile into 6 directional sub-bands with orientations in +/-15, 45, and 75 degrees and a low-pass band, which is the decimated version of the input. We apply 3 scales of decomposition by recursively transforming the low-pass bands and obtain 18 bands of different directionality at different scales. We then calculate mean and variance of each band resulting in a feature vector of 36 entries. Feature vectors obtained for each stack of tiles in axial direction are then clustered using spectral clustering in order to detect the textural changes in depth direction. Testing on a set of 15 RCM stacks produced a mean error of 5.45+/-1.32 μm, compared to the "ground truth" segmentation provided by a clinical expert reader.

  15. Optical Methods and Instrumentation in Brain Imaging and Therapy

    CERN Document Server

    2013-01-01

    This book provides a comprehensive up-to-date review of optical approaches used in brain imaging and therapy. It covers a variety of imaging techniques including diffuse optical imaging, laser speckle imaging, photoacoustic imaging and optical coherence tomography. A number of laser-based therapeutic approaches are reviewed, including photodynamic therapy, fluorescence guided resection and photothermal therapy. Fundamental principles and instrumentation are discussed for each imaging and therapeutic technique. Represents the first publication dedicated solely to optical diagnostics and therapeutics in the brain Provides a comprehensive review of the principles of each imaging/therapeutic modality Reviews the latest advances in instrumentation for optical diagnostics in the brain Discusses new optical-based therapeutic approaches for brain diseases

  16. Sample size importantly limits the usefulness of instrumental variable methods, depending on instrument strength and level of confounding.

    Science.gov (United States)

    Boef, Anna G C; Dekkers, Olaf M; Vandenbroucke, Jan P; le Cessie, Saskia

    2014-11-01

    Instrumental variable (IV) analysis is promising for estimation of therapeutic effects from observational data as it can circumvent unmeasured confounding. However, even if IV assumptions hold, IV analyses will not necessarily provide an estimate closer to the true effect than conventional analyses as this depends on the estimates' bias and variance. We investigated how estimates from standard regression (ordinary least squares [OLS]) and IV (two-stage least squares) regression compare on mean squared error (MSE). We derived an equation for approximation of the threshold sample size, above which IV estimates have a smaller MSE than OLS estimates. Next, we performed simulations, varying sample size, instrument strength, and level of unmeasured confounding. IV assumptions were fulfilled by design. Although biased, OLS estimates were closer on average to the true effect than IV estimates at small sample sizes because of their smaller variance. The threshold sample size above which IV analysis outperforms OLS regression depends on instrument strength and strength of unmeasured confounding but will usually be large given the typical moderate instrument strength in medical research. IV methods are of most value in large studies if considerable unmeasured confounding is likely and a strong and plausible instrument is available. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Stacking Analysis of Binary Systems with HAWC

    Science.gov (United States)

    Brisbois, Chad; HAWC Collaboration

    2017-01-01

    Detecting binary systems at TeV energies is an important problem because only a handful of such systems are currently known. The nature of such systems is typically thought to be composed of a compact object and a massive star. The TeV emission from these systems does not obviously correspond to emission in GeV or X-ray, where many binary systems have previously been found. This study focuses on a stacking method to detect TeV emission from LS 5039, a known TeV binary, to test its efficacy in HAWC data. Stacking is a widely employed method for increasing signal to noise ratio in optical astronomy, but has never been attempted previously with HAWC. HAWC is an ideal instrument to search for TeV binaries, because of its wide field of view and high uptime. Applying this method to the entire sky may allow HAWC to detect binary sources of very short or very long periods not sensitive to current analyses. NSF, DOE, Los Alamos, Michigan Tech, CONACyt, UNAM, BUAP.

  18. Hydrogen Embrittlement And Stacking-Fault Energies

    Science.gov (United States)

    Parr, R. A.; Johnson, M. H.; Davis, J. H.; Oh, T. K.

    1988-01-01

    Embrittlement in Ni/Cu alloys appears related to stacking-fault porbabilities. Report describes attempt to show a correlation between stacking-fault energy of different Ni/Cu alloys and susceptibility to hydrogen embrittlement. Correlation could lead to more fundamental understanding and method of predicting susceptibility of given Ni/Cu alloy form stacking-fault energies calculated from X-ray diffraction measurements.

  19. High-throughput computer method for 3D neuronal structure reconstruction from the image stack of the Drosophila brain and its applications.

    Directory of Open Access Journals (Sweden)

    Ping-Chang Lee

    Full Text Available Drosophila melanogaster is a well-studied model organism, especially in the field of neurophysiology and neural circuits. The brain of the Drosophila is small but complex, and the image of a single neuron in the brain can be acquired using confocal microscopy. Analyzing the Drosophila brain is an ideal start to understanding the neural structure. The most fundamental task in studying the neural network of Drosophila is to reconstruct neuronal structures from image stacks. Although the fruit fly brain is small, it contains approximately 100,000 neurons. It is impossible to trace all the neurons manually. This study presents a high-throughput algorithm for reconstructing the neuronal structures from 3D image stacks collected by a laser scanning confocal microscope. The proposed method reconstructs the neuronal structure by applying the shortest path graph algorithm. The vertices in the graph are certain points on the 2D skeletons of the neuron in the slices. These points are close to the 3D centerlines of the neuron branches. The accuracy of the algorithm was verified using the DIADEM data set. This method has been adopted as part of the protocol of the FlyCircuit Database, and was successfully applied to process more than 16,000 neurons. This study also shows that further analysis based on the reconstruction results can be performed to gather more information on the neural network.

  20. Tritium instrumentation for a fusion reactor power plant

    International Nuclear Information System (INIS)

    Shank, K.E.; Easterly, C.E.

    1976-09-01

    A review of tritium instrumentation is presented. This includes a discussion of currently available in-plant instrumentation and methods required for sampling stacks, monitoring process streams and reactor coolants, analyzing occupational work areas for air and surface contamination, and personnel monitoring. Off-site instrumentation and collection techniques are also presented. Conclusions are made concerning the adequacy of existing instrumentation in relation to the monitoring needs for fusion reactors

  1. A Geometrical Method for Sound-Hole Size and Location Enhancement in Lute Family Musical Instruments: The Golden Method

    Directory of Open Access Journals (Sweden)

    Soheil Jafari

    2017-11-01

    Full Text Available This paper presents a new analytical approach, the Golden Method, to enhance sound-hole size and location in musical instruments of the lute family in order to obtain better sound damping characteristics based on the concept of the golden ratio and the instrument geometry. The main objective of the paper is to increase the capability of lute family musical instruments in keeping a note for a certain time at a certain level to enhance the instruments’ orchestral characteristics. For this purpose, a geometry-based analytical method, the Golden Method is first described in detail in an itemized feature. A new musical instrument is then developed and tested to confirm the ability of the Golden Method in optimizing the acoustical characteristics of musical instruments from a damping point of view by designing the modified sound-hole. Finally, the new-developed instrument is tested, and the obtained results are compared with those of two well-known instruments to confirm the effectiveness of the proposed method. The experimental results show that the suggested method is able to increase the sound damping time by at least 2.4% without affecting the frequency response function and other acoustic characteristics of the instrument. This methodology could be used as the first step in future studies on design, optimization and evaluation of musical instruments of the lute family (e.g., lute, oud, barbat, mandolin, setar, and etc..

  2. Instrumental and statistical methods for the comparison of class evidence

    Science.gov (United States)

    Liszewski, Elisa Anne

    Trace evidence is a major field within forensic science. Association of trace evidence samples can be problematic due to sample heterogeneity and a lack of quantitative criteria for comparing spectra or chromatograms. The aim of this study is to evaluate different types of instrumentation for their ability to discriminate among samples of various types of trace evidence. Chemometric analysis, including techniques such as Agglomerative Hierarchical Clustering, Principal Components Analysis, and Discriminant Analysis, was employed to evaluate instrumental data. First, automotive clear coats were analyzed by using microspectrophotometry to collect UV absorption data. In total, 71 samples were analyzed with classification accuracy of 91.61%. An external validation was performed, resulting in a prediction accuracy of 81.11%. Next, fiber dyes were analyzed using UV-Visible microspectrophotometry. While several physical characteristics of cotton fiber can be identified and compared, fiber color is considered to be an excellent source of variation, and thus was examined in this study. Twelve dyes were employed, some being visually indistinguishable. Several different analyses and comparisons were done, including an inter-laboratory comparison and external validations. Lastly, common plastic samples and other polymers were analyzed using pyrolysis-gas chromatography/mass spectrometry, and their pyrolysis products were then analyzed using multivariate statistics. The classification accuracy varied dependent upon the number of classes chosen, but the plastics were grouped based on composition. The polymers were used as an external validation and misclassifications occurred with chlorinated samples all being placed into the category containing PVC.

  3. Geology Structure Identification Using Pre-Stack Depth Migration (PSDM Method of Tomography Result in North West Java Basin

    Directory of Open Access Journals (Sweden)

    Sudra Irawan

    2017-06-01

    Full Text Available North West Java Basin is a tertiary sedimentary basin which is located in the right of the western part of the Java island. North West Java Basin is geodynamic where currently located at the rear position of the path of the volcanic arc of Java that is the result of the India-Australia plate subduction to the south towards the Eurasian plate (Explanation of Sunda in the north. Geology structure observation is difficult to be conducted at Quaternary volcanicfield due to the classical problem at tropical region. In the study interpretation of fault structures can be done on a cross-section of Pre-Stack Depth Migration (PSDM used prayer namely Hardware Key Device, ie Central Processing Unit: RedHat Enterprise Linux AS 5.0, prayer Monitor 24-inch pieces, Server: SGI altix 450/SuSe Linux Enterprise Server 9.0, 32 GB, 32 X 2,6 GHz Procesor, network: Gigabyte 1 Gb/s, and the software used is paradigm, product: Seismic Processing and Imaging. The third fault obtained in this study in accordance with the geological information derived from previous research conducted by geologists. The second general direction is northwest-southeast direction represented by Baribis fault, fault-fault in the Valley Cimandiri and Gunung Walat. This direction is often known as the directions Meratus (Meratus Trend. Meratus directions interpreted as directions that follow the pattern of continuous arc Cretaceous age to Meratus in Kalimantan.

  4. Asymmetric Flexible Supercapacitor Stack

    Directory of Open Access Journals (Sweden)

    Leela Mohana Reddy A

    2008-01-01

    Full Text Available AbstractElectrical double layer supercapacitor is very significant in the field of electrical energy storage which can be the solution for the current revolution in the electronic devices like mobile phones, camera flashes which needs flexible and miniaturized energy storage device with all non-aqueous components. The multiwalled carbon nanotubes (MWNTs have been synthesized by catalytic chemical vapor deposition technique over hydrogen decrepitated Mischmetal (Mm based AB3alloy hydride. The polymer dispersed MWNTs have been obtained by insitu polymerization and the metal oxide/MWNTs were synthesized by sol-gel method. Morphological characterizations of polymer dispersed MWNTs have been carried out using scanning electron microscopy (SEM, transmission electron microscopy (TEM and HRTEM. An assymetric double supercapacitor stack has been fabricated using polymer/MWNTs and metal oxide/MWNTs coated over flexible carbon fabric as electrodes and nafion®membrane as a solid electrolyte. Electrochemical performance of the supercapacitor stack has been investigated using cyclic voltammetry, galvanostatic charge-discharge, and electrochemical impedance spectroscopy.

  5. A review of sensory and instrumental methods used to evaluate the texture of fish muscle

    DEFF Research Database (Denmark)

    Hyldig, Grethe; Nielsen, Durita

    2001-01-01

    in the mouth, until it is completely masticated. This makes texture difficult to describe and evaluate. In addition the muscle structure of fish is not homogenous, and this has important implications on texture measurements by instrumental means. Numerous instrumental and sensory methods have been used...... to evaluate the texture of fish and fish fillets, with varying results and there exists no universal recommended method....

  6. Methods For Calculating Thyroid Doses to The Residents Of Ozersk Due to 131I Releases From The Stacks of The Mayak Production Association

    Energy Technology Data Exchange (ETDEWEB)

    Rovny, Sergey I.; Mokrov, Y.; Stukalov, Pavel M.; Beregich, D. A.; Teplyakov, I. I.; Anspaugh, L. R.; Napier, Bruce A.

    2009-10-23

    The Mayak Production Association (MPA) was established in the late 1940s in accordance with a special Decree of the USSR Government for the production of nuclear weapons. In early years of MPA operation, due to the lack of experience and absence of effective methods of RW management, the enterprise had extensive routine (designed) and non-routine (accidental) releases of gaseous radioactive wastes to the atmosphere. These practices resulted in additional technogenic radiation exposure of residents inhabiting populated areas near the MPA. The primary objective of ongoing studies under JCCRER Project 1.4 is to estimate doses to the residents of Ozersk due to releases of radioactive substances from the stacks of MPA. Preliminary scoping studies have demonstrated that releases of radioactive iodine (131I) from the stacks of the Mayak Radiochemical Plant represented the major contribution to the dose to residents of Ozersk and of other nearby populated areas. The behavior of 131I in the environment and of 131I migration through biological food chains (vegetation-cows-milk-humans) indicated a need for use of special mathematical models to perform the estimation of radiation doses to the population. The goal of this work is to select an appropriate model of the iodine migration in biological food chains and to justify numerical values of the model parameters.

  7. Deploying OpenStack

    CERN Document Server

    Pepple, Ken

    2011-01-01

    OpenStack was created with the audacious goal of being the ubiquitous software choice for building public and private cloud infrastructures. In just over a year, it's become the most talked-about project in open source. This concise book introduces OpenStack's general design and primary software components in detail, and shows you how to start using it to build cloud infrastructures. If you're a developer, technologist, or system administrator familiar with cloud offerings such as Rackspace Cloud or Amazon Web Services, Deploying OpenStack shows you how to obtain and deploy OpenStack softwar

  8. A Workshop on Methods for Neutron Scattering Instrument Design. Introduction and Summary

    International Nuclear Information System (INIS)

    Hjelm, Rex P.

    1996-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop on ''Methods for Neutron Scattering Instrument Design'' September 23-25 at the E.O. Lawrence Berkeley National Laboratory. These proceedings are a collection of a portion of the invited and contributed presentations

  9. 3D position estimation of flexible instruments: marker-less and marker-based methods

    NARCIS (Netherlands)

    Reilink, Rob; Stramigioli, Stefano; Misra, Sarthak

    2013-01-01

    Purpose Endoscopic images can be used to allow accurate flexible endoscopic instrument control. This can be implemented using a pose estimation algorithm, which estimates the actual instrument pose from the endoscopic images. Methods In this paper, two pose estimation algorithms are compared: a

  10. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  11. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  12. Applying lean methods to improve quality and safety in surgical sterile instrument processing.

    Science.gov (United States)

    Blackmore, C Craig; Bishop, Robbi; Luker, Samuel; Williams, Barbara L

    2013-03-01

    Surgical instrument processing is critical to safe, high-quality surgical care but has received little attention in the medical literature. Typical hospitals have inventories in the tens of thousands of surgical instruments organized into thousands of instrument sets. The use of these instruments for multiple procedures per day leads to millions of instrument sets being reprocessed yearly in a single hospital. Errors in the processing of sterile instruments may lead to increased operative times and costs, as well as potentially contributing to surgical infections and perioperative morbidity. At Virginia Mason Medical Center (Seattle), a quality monitoring approach was developed to identify and categorize errors in sterile instrument processing, through use of a daily defect sheet. Lean methods were used to improve the quality of surgical instrument processing through redefining operator roles, alteration of the workspace, mistake-proofing, quality monitoring, staff training, and continuous feedback. To study the effectiveness of the quality improvement project, a before/after comparison of prospectively collected sterile processing error rates during a 37-month time frame was performed. Before the intervention, instrument processing errors occurred in 3.0% of surgical cases, decreasing to 1.5% at the final follow-up (p instrument processing errors are a barrier to the highest quality and safety in surgical care but are amenable to substantial improvement using Lean techniques.

  13. Magnetic characterisation of recording materials: design, instrumentation and experimental methods

    NARCIS (Netherlands)

    Samwel, E.O.

    1995-01-01

    The progress being made in the field of magnetic recording is extremely fast. The need to keep this progress going, leads to new types of recording materials which require advanced measurement systems and measurement procedures. Furthermore, the existing measurement methods need to be reviewed as

  14. OpenStack essentials

    CERN Document Server

    Radez, Dan

    2015-01-01

    If you need to get started with OpenStack or want to learn more, then this book is your perfect companion. If you're comfortable with the Linux command line, you'll gain confidence in using OpenStack.

  15. Mastering OpenStack

    CERN Document Server

    Khedher, Omar

    2015-01-01

    This book is intended for system administrators, cloud engineers, and system architects who want to deploy a cloud based on OpenStack in a mid- to large-sized IT infrastructure. If you have a fundamental understanding of cloud computing and OpenStack and want to expand your knowledge, then this book is an excellent checkpoint to move forward.

  16. Microfabricated instruments and methods to treat recurrent corneal erosions

    Science.gov (United States)

    Britton, Jr., Charles L.; D'urso, Brian R.; Chaum, Edward; Simpson, John T.; Baba, Justin S.; Ericson, M. Nance; Warmack, Robert J.

    2015-06-02

    In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman's layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman's layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.

  17. Microfabricated instruments and methods to treat recurrent corneal erosions

    Energy Technology Data Exchange (ETDEWEB)

    Britton, Jr., Charles L.; D' urso, Brian R.; Chaum, Edward; Simpson, John T.; Baba, Justin S.; Ericson, M. Nance; Warmack, Robert J.

    2015-06-02

    In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman's layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman's layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.

  18. Microfabricated instruments and methods to treat recurrent corneal erosion

    Science.gov (United States)

    Britton, Charles L; D& #x27; Urso, Brian R; Chaum, Edward; Simpson, John T; Baba, Justin S; Ericson, M. Nance; Warmack, Robert J

    2013-11-26

    In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman's layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman's layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.

  19. Method of charging instruments into liquid metal coolant

    International Nuclear Information System (INIS)

    Yamazaki, Hiroshi

    1980-01-01

    Purpose: To alleviate the thermal shock of a reactor charging machine when charging the machine into liquid metal coolant after the machine is preheated in cover gas. Method: When a reactor fueling machine reaches at the lowermost portion the position immediately above liquid metal coolant surface level, the machine is stopped moving down. The reactor fueling machine is heated at the lowermost portion by thermal radiation from the surface of the liquid metal coolant. After the machine is thus preheated in cover gas, it is again steadily moved down by a winch and charged into the liquid metal coolant. Therefore, the thermal shock of the machine becomes low when charging the machine into the liquid metal coolant to eliminate the damage and deformation at the machine. (Yoshihara, H.)

  20. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

    Science.gov (United States)

    Gambarini, Gianluca; Grande, Nicola Maria; Plotino, Gianluca; Somma, Francesco; Garala, Manish; De Luca, Massimo; Testarelli, Luca

    2008-08-01

    The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

  1. Investigation of chemometric instrumental transfer methods for high-resolution NMR.

    Science.gov (United States)

    Alam, Todd M; Alam, M Kathleen; McIntyre, Sarah K; Volk, David E; Neerathilingam, Muniasamy; Luxon, Bruce A

    2009-06-01

    The implementation of direct standardization (DS), piecewise direct standardization (PDS), and double-window piecewise direct standardization (DWPDS) instrumental transfer techniques for high-resolution (1)H NMR spectral data was explored. The ability to transfer a multivariate calibration model developed for a "master or target" NMR instrument configuration to seven different ("secondary") NMR instrument configurations was measured. Partial least-squares (PLS) calibration of glucose, glycine, and citrate metabolite relative concentrations in model mixtures following mapping of the secondary instrumental configurations using DS, PDS, or DWPDS instrumental transfer allowed the performance of the different transfer methods to be assessed. Results from these studies suggest that DS and PDS transfer techniques produce similar improvements in the error of prediction compared to each other and provide a significant improvement over standard spectral preprocessing techniques including reference deconvolution and spectral binning. The DS instrumental transfer method produced the largest percent improvement in the predictions of concentrations for these model mixtures but, in general, required that additional transfer calibration standards be used. Limitations of the different instrumental transfer methods with respect to sample subset selection are also discussed.

  2. Notes on G-theory of Deligne-Mumford stacks

    OpenAIRE

    Toen, B.

    1999-01-01

    Based on the methods used by the author to prove the Riemann-Roch formula for algebraic stacks, this paper contains a description of the rationnal G-theory of Deligne-Mumford stacks over general bases. We will use these results to study equivariant K-theory, and also to define new filtrations on K-theory of algebraic stacks.

  3. DEVS Models of Palletized Ground Stacking in Storeyed Grain Warehouse

    Directory of Open Access Journals (Sweden)

    Hou Shu-Yi

    2016-01-01

    Full Text Available Processed grain stored in storeyed warehouse is generally stacked on the ground without pallets. However, in order to improve the storing way, we developed a new stacking method, palletized ground stacking. Simulation should be used to present this new storing way. DEVS provides a formalized way to describe the system model. In this paper, DEVS models of palletized ground stacking in storeyed grain warehouse are given and a simulation model is developed by AutoMod.

  4. Method of operating a molten carbonate fuel cell, a fuel cell, a fuel cell stack and an apparatus provided therewith

    NARCIS (Netherlands)

    Hemmes, K.; Dijkema, G.P.J.

    1998-01-01

    A method of operating a molten carbonate fuel cell having an anode and a cathode and in between a matrix comprising molten carbonate. Carbon dioxide is introduced into the matrix at a distance from the cathode. This greatly reduces the cathode's deterioration and in the system design increases the

  5. A method for the deliberate and deliberative selection of policy instrument mixes for climate change adaptation

    Directory of Open Access Journals (Sweden)

    Heleen L. P. Mees

    2014-06-01

    Full Text Available Policy instruments can help put climate adaptation plans into action. Here, we propose a method for the systematic assessment and selection of policy instruments for stimulating adaptation action. The multi-disciplinary set of six assessment criteria is derived from economics, policy, and legal studies. These criteria are specified for the purpose of climate adaptation by taking into account four challenges to the governance of climate adaptation: uncertainty, spatial diversity, controversy, and social complexity. The six criteria and four challenges are integrated into a step-wise method that enables the selection of instruments starting from a generic assessment and ending with a specific assessment of policy instrument mixes for the stimulation of a specific adaptation measure. We then apply the method to three examples of adaptation measures. The method's merits lie in enabling deliberate choices through a holistic and comprehensive set of adaptation specific criteria, as well as deliberative choices by offering a stepwise method that structures an informed dialog on instrument selection. Although the method was created and applied by scientific experts, policy-makers can also use the method.

  6. Tundish Cover Flux Thickness Measurement Method and Instrumentation Based on Computer Vision in Continuous Casting Tundish

    Directory of Open Access Journals (Sweden)

    Meng Lu

    2013-01-01

    Full Text Available Thickness of tundish cover flux (TCF plays an important role in continuous casting (CC steelmaking process. Traditional measurement method of TCF thickness is single/double wire methods, which have several problems such as personal security, easily affected by operators, and poor repeatability. To solve all these problems, in this paper, we specifically designed and built an instrumentation and presented a novel method to measure the TCF thickness. The instrumentation was composed of a measurement bar, a mechanical device, a high-definition industrial camera, a Siemens S7-200 programmable logic controller (PLC, and a computer. Our measurement method was based on the computer vision algorithms, including image denoising method, monocular range measurement method, scale invariant feature transform (SIFT, and image gray gradient detection method. Using the present instrumentation and method, images in the CC tundish can be collected by camera and transferred to computer to do imaging processing. Experiments showed that our instrumentation and method worked well at scene of steel plants, can accurately measure the thickness of TCF, and overcome the disadvantages of traditional measurement methods, or even replace the traditional ones.

  7. Vibrational sensitivity of a measuring instrument and methods of increasing the accuracy of its determinations

    Science.gov (United States)

    Mironov, Y. S.

    1973-01-01

    The properties and peculiarities of two groups of measuring systems reacting to vibrations are discussed. Specifically, results of the action of a three dimensional, cophasal, monoharmonic vibration on the linear system of a measuring instrument was analyzed. Data are also given on the connection between vibration sensitivity and vibration resistance for instruments, methods for estimating vibration resistance, and formulas for expressing test results of vibration resistance. Experimental data are also given for decreasing errors in nonlinear systems during vibrations.

  8. THE REGULATION OF MONEY CIRCULATION ON THE BASIS OF USING METHODS AND INSTRUMENTS OF MONETARY POLICY

    Directory of Open Access Journals (Sweden)

    S. Mishchenko

    2013-05-01

    Full Text Available In the article it was researched the instruments and mechanism of safeguarding stability of money market on the basis of implementing the optimal monetary policy regime. It was determined the main directions of appliance the monetary policy methods and instruments to guiding money market stability and it was also investigated the influence of transmission mechanism on providing the soundness of money circulations.

  9. Tunable electro-optic filter stack

    Energy Technology Data Exchange (ETDEWEB)

    Fontecchio, Adam K.; Shriyan, Sameet K.; Bellingham, Alyssa

    2017-09-05

    A holographic polymer dispersed liquid crystal (HPDLC) tunable filter exhibits switching times of no more than 20 microseconds. The HPDLC tunable filter can be utilized in a variety of applications. An HPDLC tunable filter stack can be utilized in a hyperspectral imaging system capable of spectrally multiplexing hyperspectral imaging data acquired while the hyperspectral imaging system is airborne. HPDLC tunable filter stacks can be utilized in high speed switchable optical shielding systems, for example as a coating for a visor or an aircraft canopy. These HPDLC tunable filter stacks can be fabricated using a spin coating apparatus and associated fabrication methods.

  10. Research on data analysis method of non-destructive assay radioactive waste measurement instrument

    International Nuclear Information System (INIS)

    Zhou Zhibo; He Lixia; Shao Jiewen; Sui Hongzhi; Gan Lin

    2008-01-01

    The research concerns in the data analysis and detection efficiency calculation based on Monte-Carlo method for non-destructive assay radioactive waste measurement instrument. The rationality of the methods was experimentally tested, and the tested result shows that the relative deviation between calculated and nominal 235 U content is within 10%. (authors)

  11. 30 CFR 75.1719-3 - Methods of measurement; light measuring instruments.

    Science.gov (United States)

    2010-07-01

    ... being measured and a sufficient distance from the surface to allow the light sensing element in the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methods of measurement; light measuring... § 75.1719-3 Methods of measurement; light measuring instruments. (a) Compliance with § 75.1719-1(d...

  12. Method of case hardening depth testing by using multifunctional ultrasonic testing instrument

    International Nuclear Information System (INIS)

    Salchak, Y A; Sednev, D A; Ardashkin, I B; Kroening, M

    2015-01-01

    The paper describes usability of ultrasonic case hardening depth control applying standard instrument of ultrasonic inspections. The ultrasonic method of measuring the depth of the hardened layer is proposed. Experimental series within the specified and multifunctional ultrasonic equipment are performed. The obtained results are compared with the results of a referent method of analysis. (paper)

  13. Device application of AgGa0.5In0.5Se2 thin films deposited by thermal sequential stacked layer method

    Science.gov (United States)

    Coşkun, E.; Güllü, H. H.; Parlak, M.

    2014-12-01

    An In/n-AgGa0.5In0.5Se2/p-Si/Al heterostructure was produced by thermal sequential stacked layer deposition method and the device characteristics were investigated. The compositional analysis showed that the depositions of the intended stoichiometric composition of AgGa0.5In0.5Se2 structure were obtainable by controlling and providing the necessary deposition conditions during the deposition processes. By means of the room temperature Hall effect and transmission measurements, the carrier concentration and optical band gap values were determined as 9× {{10}15} cm-3 and 1.65 eV, respectively. In addition, temperature-dependent current-voltage (I-V) and the room temperature capacitance-voltage (C-V) measurements of this heterostructure were carried out. The rectification factor was obtained as about 104 at 1.20 V for all sample temperatures. Depending on the change in the temperature, the series and shunt resistances were calculated as 101 and 106 Ω, respectively. The studies on the current transport mechanisms showed that there were two different mechanisms at two different voltage regions: tunneling enhanced recombination mechanism in the voltage range of 0.08 and 0.30 V and the space charge limited current mechanism in the voltage range of 0.30 and 0.60 V. The barrier height, built-in potential and interface states density of the deposited heterostructure were also calculated and discussed.

  14. Neutron monitoring systems including gamma thermometers and methods of calibrating nuclear instruments using gamma thermometers

    Science.gov (United States)

    Moen, Stephan Craig; Meyers, Craig Glenn; Petzen, John Alexander; Foard, Adam Muhling

    2012-08-07

    A method of calibrating a nuclear instrument using a gamma thermometer may include: measuring, in the instrument, local neutron flux; generating, from the instrument, a first signal proportional to the neutron flux; measuring, in the gamma thermometer, local gamma flux; generating, from the gamma thermometer, a second signal proportional to the gamma flux; compensating the second signal; and calibrating a gain of the instrument based on the compensated second signal. Compensating the second signal may include: calculating selected yield fractions for specific groups of delayed gamma sources; calculating time constants for the specific groups; calculating a third signal that corresponds to delayed local gamma flux based on the selected yield fractions and time constants; and calculating the compensated second signal by subtracting the third signal from the second signal. The specific groups may have decay time constants greater than 5.times.10.sup.-1 seconds and less than 5.times.10.sup.5 seconds.

  15. A review of sensory and instrumental methods used to evaluate the texture of fish muscle

    DEFF Research Database (Denmark)

    Hyldig, Grethe; Nielsen, Durita

    2001-01-01

    The texture of fish muscle is an important quality attribute that depends on several parameters, both intrinsic and extrinsic. Its evaluation by sensory means is the result of a combination of several parameters that cover every impression from when the fish first comes into contact with a surface...... in the mouth, until it is completely masticated. This makes texture difficult to describe and evaluate. In addition the muscle structure of fish is not homogenous, and this has important implications on texture measurements by instrumental means. Numerous instrumental and sensory methods have been used...... to evaluate the texture of fish and fish fillets, with varying results and there exists no universal recommended method....

  16. Evaluation of hydrogen embrittlement and temper embrittlement by key curve method in instrumented Charpy test

    Directory of Open Access Journals (Sweden)

    Makita A.

    2010-06-01

    Full Text Available Instrumented Charpy test was conducted on small sized specimen of 21/4Cr-1Mo steel. In the test the single specimen key curve method was applied to determine the value of fracture toughness for the initiation of crack extension with hydrogen free, KIC, and for hydrogen embrittlement cracking, KIH. Also the tearing modulus as a parameter for resistance to crack extension was determined. The role of these parameters was discussed at an upper shelf temperature and at a transition temperature. Then the key curve method combined with instrumented Charpy test was proven to be used to evaluate not only temper embrittlement but also hydrogen embrittlement.

  17. Calibration method based on direct radioactivity measurement for radioactive gas monitoring instruments

    International Nuclear Information System (INIS)

    Yoshida, Makoto; Ohi, Yoshihiro; Chida, Tohru; Wu, Youyang.

    1993-01-01

    A calibration method for radioactive gas monitoring instruments was studied. In the method, gaseous radioactivity standards were provided on the basis of the direct radioactivity measurement by the diffusion-in long proportional counter method (DLPC method). The radioactivity concentration of the gas mixture through a monitoring instrument was determined by sampling the known volume of the gas mixture into the proportional counter used for the DLPC method. Since oxygen in the gas mixture decreased the counting efficiency in a proportional counter, the influence on calibration was experimentally estimated. It was not serious and able to be easily corrected. By the present method, the relation between radioactivity concentration and ionization current was determined for a gas-flow ionization chamber with 1.5 l effective volume. It showed good agreement with the results in other works. (author)

  18. Factor analysis methods and validity evidence: a review of instrument development across the medical education continuum.

    Science.gov (United States)

    Wetzel, Angela P

    2012-08-01

    Instrument development consistent with best practices is necessary for effective assessment and evaluation of learners and programs across the medical education continuum. The author explored the extent to which current factor analytic methods and other techniques for establishing validity are consistent with best practices. The author conducted electronic and hand searches of the English-language medical education literature published January 2006 through December 2010. To describe and assess current practices, she systematically abstracted reliability and validity evidence as well as factor analysis methods, data analysis, and reported evidence from instrument development articles reporting the application of exploratory factor analysis and principal component analysis. Sixty-two articles met eligibility criteria. They described 64 instruments and 95 factor analyses. Most studies provided at least one source of evidence based on test content. Almost all reported internal consistency, providing evidence based on internal structure. Evidence based on response process and relationships with other variables was reported less often, and evidence based on consequences of testing was not identified. Factor analysis findings suggest common method selection errors and critical omissions in reporting. Given the limited reliability and validity evidence provided for the reviewed instruments, educators should carefully consider the available supporting evidence before adopting and applying published instruments. Researchers should design for, test, and report additional evidence to strengthen the argument for reliability and validity of these measures for research and practice.

  19. Instruments and methods for measuring radon/thoron and their progeny: calibrations, intercomparisons, and particle size

    International Nuclear Information System (INIS)

    George, A.C.; Esposito, J.Z.; Bredhoff, N.A.

    1998-01-01

    Indoor measurements of the concentrations of radon/thoron and their decay products were intensified worldwide in the last 13 years for the assessment of the radiation dose to workers and the general public. Measurements of particle size have been limited to a small group of universities and government agencies due to their complexity and high cost. A variety and plethora of instruments and methods have been developed using different principles of detection for different measurement applications. Overall, the instruments and method used today depend on whether radon, thoron or radon and thoron decay products are being measured, the type of radiation being detected, the duration of the measurement, portability, convenience, reliability and cost considerations. The instruments of interest to most of us, use the following detection systems: pulse, current and electret ionization chambers, scintillation detectors with zinc sulfide, alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, registration of nuclear tracks in solid state materials, and gamma ray spectrometry and alpha and beta liquid scintillation spectrometry with NaI(Tl) scintillation crystals or germanium lithium (GeLi) semiconductors and liquid scintillation spectrometry systems. An overview of particle sizing instruments and methods will be presented. The advantages and disadvantages, field applicability and cost of the different instruments will be discussed so the researcher or tester can select the proper one for his or her use. (author)

  20. Pre-validation methods for developing a patient reported outcome instrument

    Directory of Open Access Journals (Sweden)

    Castillo Mayret M

    2011-08-01

    Full Text Available Abstract Background Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology. Methods The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ. The five steps are: 1 Generation of a pool of items; 2 Item de-duplication (three phases; 3 Item reduction (two phases; 4 Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF; and 5 qualitative exploration of the target populations' views of the new instrument and the items it contains. Results The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items. Conclusions This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped

  1. An overview of methods and instruments for the assessment of occupational exposure to nanoparticles

    Directory of Open Access Journals (Sweden)

    Vahideh Abolhasannejad

    2015-09-01

    Full Text Available Background & objective:: In recent years, there has been a dramatic increase in the application of nanotechnology in industries and the number of workers occupied in different processes of research on and construction, production and residue disposal of products containing nanoparticles. Despite this growth, however, there is still a dearth of information on the risk of occupational exposure to these materials. Due to the growing application of nanoparticles in the workplace, selecting suitable sampling and characterization techniques and instruments as well as investigating their efficiency for the evaluation of occupational exposure is very important. Methods: The present review study was conducted to introduce the methods and instruments used for evaluating occupational exposure to nanoparticles with an emphasis on the results of the existing literature on methods and instruments of evaluating occupational exposure to nanoparticles and the different contributing factors and conditions through library resources. Results: The results of this study demonstrate that, in spite of the wide application of nanotechnology in the workplace, a reliable, international and standard method for evaluating occupational exposure to nanoparticles is still lacking. This study also shows that occupational exposure to nanoparticles can be evaluated through modern instruments that identify and characterize nanoparticles in terms of their number, mass concentration and surface area. The Scanning Mobility Particle Sizer (SMPS was the most widely-used instrument for measuring the number and size distribution of particles. Conclusion: The accuracy and precision of the methods and instruments used for evaluating the exposure to nanoparticles can be investigated in future research as a way of establishing a suitable and reliable evaluative standard.

  2. Stack filter classifiers

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Reid B [Los Alamos National Laboratory; Hush, Don [Los Alamos National Laboratory

    2009-01-01

    Just as linear models generalize the sample mean and weighted average, weighted order statistic models generalize the sample median and weighted median. This analogy can be continued informally to generalized additive modeels in the case of the mean, and Stack Filters in the case of the median. Both of these model classes have been extensively studied for signal and image processing but it is surprising to find that for pattern classification, their treatment has been significantly one sided. Generalized additive models are now a major tool in pattern classification and many different learning algorithms have been developed to fit model parameters to finite data. However Stack Filters remain largely confined to signal and image processing and learning algorithms for classification are yet to be seen. This paper is a step towards Stack Filter Classifiers and it shows that the approach is interesting from both a theoretical and a practical perspective.

  3. A new method for the radiation representation of musical instruments in auralizations

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    A new method for the representation of sound sources that vary their directivity in time in auralizations is introduced. A recording method with multi-channel anechoic recordings is proposed in connection with the use of a multiple virtual source reproduction system in auralizations. Listening ex...... to be significant. Further applications of the method are considered for ensembles within room auralizations as well as in the field of studio recording techniques for large instruments....

  4. USAGE OF PICTOGRAMS TO INTRODUCE MUSICAL INSTRUMENTS TO EDUCABLE MENTALLY RETARDED CHILDREN AS AN ALTERNATIVE METHOD

    Directory of Open Access Journals (Sweden)

    Gunsu YILMA

    2014-01-01

    Full Text Available The purpose of this research is to examine and investigate the perception ability of musical instruments of educable mentally retarded children with the support of visual elements. The research is conducted for every children individually in a special education and rehabilitation centre. The problematic of this research is the level of perception ability of musical instruments with visual support on mild mentally retarded children. In this research, perception ability of defining pictograms by music is introduced as an alternative method. It is researched that how educable mentally retarded children perceive pictograms by music tools. In this case, it is aimed to introduce musical instruments to educable mentally retarded children by pictograms with music. The research is applied with a qualitative approach. Data were obtained with the recorder, then they were turned into texts and analyzed with content analysis method.

  5. On Stack Reconstruction Problem

    Directory of Open Access Journals (Sweden)

    V. D. Аkeliev

    2009-01-01

    Full Text Available The paper describes analytical investigations that study relation of fuel combustion regimes with concentration values of sulphur anhydride in flue gases and acid dew point. Coefficients of convective heat transfer at internal and external surfaces of stacks have been determined in the paper. The paper reveals the possibility to reconstruct stacks while using gas discharging channel made of composite material on the basis of glass-reinforced plastic which permits to reduce thermo-stressed actions on reinforced concrete and increase volume of released gases due to practically two-fold reduction of gas-dynamic pressure losses along the pipe length.

  6. Wearable solar cells by stacking textile electrodes.

    Science.gov (United States)

    Pan, Shaowu; Yang, Zhibin; Chen, Peining; Deng, Jue; Li, Houpu; Peng, Huisheng

    2014-06-10

    A new and general method to produce flexible, wearable dye-sensitized solar cell (DSC) textiles by the stacking of two textile electrodes has been developed. A metal-textile electrode that was made from micrometer-sized metal wires was used as a working electrode, while the textile counter electrode was woven from highly aligned carbon nanotube fibers with high mechanical strengths and electrical conductivities. The resulting DSC textile exhibited a high energy conversion efficiency that was well maintained under bending. Compared with the woven DSC textiles that are based on wire-shaped devices, this stacked DSC textile unexpectedly exhibited a unique deformation from a rectangle to a parallelogram, which is highly desired in portable electronics. This lightweight and wearable stacked DSC textile is superior to conventional planar DSCs because the energy conversion efficiency of the stacked DSC textile was independent of the angle of incident light. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Method and instrumentation for detection of rail defects, in particular rail top defects

    NARCIS (Netherlands)

    Li, Z.; Molodova, M.

    2011-01-01

    A method and instrumentation for detection of rail defects, in particular rail top defects, in a railway-track by measuring an axle box acceleration signal of a rail vehicle, wherein a longitudinal axle box acceleration signal is used as a measure to detect the occurrence of said rail defects, in

  8. Instrumental research method of qualitative composition of landfill gas in the surface layer of landfills

    Science.gov (United States)

    Gilmanshin, I. R.; Kashapov, N. F.; Gilmanshina, S. I.; Galeeva, A. I.

    2017-09-01

    The article analyzes the practice of waste management in Russia. The system of target indicators of the efficient landfills functioning is formalized. The method of instrumental analysis of concentration and qualitative composition of landfill gas in the surface layer of the Samosyrovo landfill is presented.

  9. Applying the Mixed Methods Instrument Development and Construct Validation Process: the Transformative Experience Questionnaire

    Science.gov (United States)

    Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.

    2018-01-01

    Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…

  10. Field astrobiology research instruments and methods in moon-mars analogue site.

    NARCIS (Netherlands)

    Foing, B.H.; Stoker, C.; Zavaleta, J.; Ehrenfreund, P.; Sarrazin, P.; Blake, D.; Page, J.; Pletser, V.; Hendrikse, J.; Oliveira Lebre Direito, M.S.; Kotler, M.; Martins, Z.; Orzechowska, G.; Thiel, C.S.; Clarke, J.; Gross, J.; Wendt, L.; Borst, A.; Peters, S.; Wilhelm, M.-B.; Davies, G.R.; EuroGeoMars 2009 Team, ILEWG

    2011-01-01

    We describe the field demonstration of astrobiology instruments and research methods conducted in and from the Mars Desert Research Station (MDRS) in Utah during the EuroGeoMars campaign 2009 coordinated by ILEWG, ESA/ESTEC and NASA Ames, with the contribution of academic partners. We discuss the

  11. Using a method based on Potts Model to segment a micro-CT image stack of trabecular bones of femoral region

    International Nuclear Information System (INIS)

    Andrade, Pedro H.A. de; Cabral, Manuela O.M.; Lima, Fernando R. De A.

    2015-01-01

    Exposure Computational Models are composed basically of an anthropomorphic phantom, a Monte Carlo (MC) code, and an algorithm simulator of the radioactive source. Tomographic phantoms are developed from medical images and must be pre-processed and segmented before being coupled to a MC code (which simulates the interaction of radiation with matter). This work presents a methodology used for treatment of micro-CT images stack of a femur, obtained from a 30 year old female skeleton provided by the Imaging Laboratory for Anthropology of the University of Bristol, UK. These images contain resolution of 60 micrometers and from these a block containing only 160 x 60 x 160 pixels of trabecular tissues and bone marrow was cut and saved as ⁎.sgi file (header + ⁎.raw file). The Grupo de Dosimetria Numerica (Recife-PE, Brazil) developed a software named Digital Image Processing (DIP), in which a method for segmentation based on a physical model for particle interaction known as Potts Model (or q-Ising) was implemented. This model analyzes the statistical dependence between sites in a network. In Potts Model, when the values of spin variables at neighboring sites are identical, it is assigned an 'energy of interaction' between them. Otherwise, it is said that the sites do not interact. Making an analogy between network sites and the pixels of a digital image and, moreover, between the spins variables and the intensity of the gray scale, it was possible to apply this model to obtain texture descriptors and segment the image. (author)

  12. Using a method based on Potts Model to segment a micro-CT image stack of trabecular bones of femoral region

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Pedro H.A. de; Cabral, Manuela O.M., E-mail: andrade.pha@gmail.com [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Engenharia Nuclear; Vieira, Jose W.; Correia, Filipe L. de B., E-mail: jose.wilson59@uol.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Lima, Fernando R. De A., E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (brazil)

    2015-07-01

    Exposure Computational Models are composed basically of an anthropomorphic phantom, a Monte Carlo (MC) code, and an algorithm simulator of the radioactive source. Tomographic phantoms are developed from medical images and must be pre-processed and segmented before being coupled to a MC code (which simulates the interaction of radiation with matter). This work presents a methodology used for treatment of micro-CT images stack of a femur, obtained from a 30 year old female skeleton provided by the Imaging Laboratory for Anthropology of the University of Bristol, UK. These images contain resolution of 60 micrometers and from these a block containing only 160 x 60 x 160 pixels of trabecular tissues and bone marrow was cut and saved as ⁎.sgi file (header + ⁎.raw file). The Grupo de Dosimetria Numerica (Recife-PE, Brazil) developed a software named Digital Image Processing (DIP), in which a method for segmentation based on a physical model for particle interaction known as Potts Model (or q-Ising) was implemented. This model analyzes the statistical dependence between sites in a network. In Potts Model, when the values of spin variables at neighboring sites are identical, it is assigned an 'energy of interaction' between them. Otherwise, it is said that the sites do not interact. Making an analogy between network sites and the pixels of a digital image and, moreover, between the spins variables and the intensity of the gray scale, it was possible to apply this model to obtain texture descriptors and segment the image. (author)

  13. Comparison between the Classic Sensor Embedding Method and the Monitoring Patch Embedding Method for Composites Instrumentation

    Science.gov (United States)

    Torres, M.; Collombet, F.; Douchin, B.; Crouzeix, L.; Grunevald, Y.-H.

    2014-10-01

    In this paper, the classic embedding technique, with bared sensors, and a recent proposal, the monitoring patch, are compared with the aim to improve the composites in-core instrumentation. The monitoring patch emerges with the need to industrialize sensors integration inside composite structures; thus, a complete evaluation of its mechanical performance has to be done. Numerical and experimental campaigns are carried out on elementary carbon-epoxy coupons to evaluate the benefits and disadvantages of this procedure compared with the typical interlayer sensor embedding. The results show that the use of monitoring patch does not affect significantly the mechanical performance of instrumented coupons. An instrumentation transfer function (ITF) is proposed to link the information that electronic devices can detect, the mechanical phenomena around these electronic devices and the measurements data acquired by global or local techniques (DIC, FEM, gauges). A good correlation between the strain data acquired and the strain values calculated by FEM confirms the approach of the ITF to evaluate the influence of the monitoring patch on the measured signal.

  14. po_stack_movie

    DEFF Research Database (Denmark)

    2009-01-01

    po_stack® er et reolsystem, hvis enkle elementer giver stor flexibilitet, variation og skulpturel virkning. Elementerne stables og forskydes frit, så reolens rum kan vendes til begge sider, være åbne eller lukkede og farvekombineres ubegrænset. Reolen kan let ombygges, udvides eller opdeles, når ...

  15. Learning SaltStack

    CERN Document Server

    Myers, Colton

    2015-01-01

    If you are a system administrator who manages multiple servers, then you know how difficult it is to keep your infrastructure in line. If you've been searching for an easier way, this book is for you. No prior experience with SaltStack is required.

  16. A review of modern instrumental methods of elemental analysis of petroleum related material. Part 2

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1991-01-01

    In this paper a review is presented of the state of the art in elemental analysis of petroleum-related materials (crude oil, gasoline, additives, and lubricants) using modern instrumental analysis techniques. The major instrumental techniques used for elemental analysis of petroleum products include atomic absorption spectrometry (both with flame and with graphite furnace atomizer), inductively coupled plasma atomic emission spectrometry, ion chromatography, microelemental methods, neutron activation, spark source mass spectrometry, and x-ray fluorescence. Each of these techniques is compared for its advantages, disadvantages, and typical applications in the petroleum field

  17. Determination of the stacking fault energies of face centured cubic metals and alloys by X-rays diffraction

    International Nuclear Information System (INIS)

    Borges, J.F.A.; Padilha, A.F.; Imakuma, K.

    1988-03-01

    An X-rays diffraction method was applied to measure the Stacking Fault Energies (SFE) of the AISI 304, AISI 316, AISI 347 and DIN-WERKSTOFF 1.4970 Austenitic Stainless Steels. The SFE determination plays an important role in the research of the mecanichal behaviour of the Metal and Alloys, their deformation mechanisms, stability of micro-structure and electronic configuration. The method is based on the relationship between the SFE and the ratio of the Mean Square Strains to the Stacking-Fault probability. The Mean Square Strain was evaluated by Fourier Analysis of X-rays Diffaction profiles, corrected to reduce instrumental effects, followed by the application of the Warren-Averbach method to the Fourier Coefficients. The Stacking-Fault probabilities were derived from the changes of peak separations between cold-worked and annealed specimens. (author) [pt

  18. Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

    Science.gov (United States)

    Davila, Pamela S.; Bolcar, Matthew R.; Boss, B.; Dean, B.; Hapogian, J.; Howard, J.; Unger, B.; Wilson, M.

    2006-01-01

    The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

  19. DEVELOPMENT AND VALIDATION OF 2P2S INSTRUMENT BY MIX METHODS

    Directory of Open Access Journals (Sweden)

    Nancy Ng Yut Kuan

    2017-12-01

    Full Text Available Lack of pedagogical content knowledge in questioning skills and how they were observed, lack of co-operation and not diversified teaching methods that can stimulate the cognitive, psychomotor and affective domains in students, making all of these gaps in the research literature. Thus, the researchers makes the development and validation of instruments for identifying Mathematics teachers perception about knowledge, simulation models, clinical observation and synergy (2P2S in Professional Learning Community: Lesson Study. The population is consist of primary and secondary schools in three districts as known Beluran, Telupid and Sandakan, in the such eastern part of Sabah. The samples were the 30 primary Mathematics teachers who were non randomly and purposive selected who have been teaching at least more than 1 year. In mix methods, researchers can analyzed and used the model IDCV which contains 10 detailed and interactive phases to develop quantitative instrument optimally. The revised 2P2S instrument validation phase of quantitative analysis involves Rasch measurement model. This instrument has good person reliability at 0.90 and an excellent item realibility at 0.92. This instrument has a Standard Error of Measurement (SE which is low, ± 0.19 logit. Both Infit MNSQ and the z-std are close to ideal value of 1 and 0 [(Infit MNSQ Person = 0.97; z-std = -0.1, (Infit MNSQ Item = 0.98; z-std = 0.0] which is you can imagine the suitability of instruments to measure what should be measured based on the underlying theorems.

  20. Atomic absorption spectrometry and other instrumental methods for quantitative measurements of arsenic

    International Nuclear Information System (INIS)

    Brooks, R.R.; Ryan, D.E.; Zhang, H.

    1981-01-01

    Progress in instrumental methods for quantification of arsenic during the past decade is reviewed. Particular emphasis is placed on atomic absorption spectrometry, where major progress has been made in flame methods in conjunction with hydride generation procedures and in electrothermal methods with the graphite furnace. Specific materials in which arsenic is quantified by atomic absorption techniques are also listed. Progress in the application of neutron activation-γ-spectrometry, emission spectrometry, electrometric methods, X-ray procedures and atomic fluorescence spectrometry is also reviewed. The limits of detection and time requirements of all the techniques are compared. (Auth.)

  1. Detailed Electrochemical Characterisation of Large SOFC Stacks

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2012-01-01

    As solid oxide fuel cell (SOFC) technology is moving closer to a commercial break through, lifetime limiting factors, determination of the limits of safe operation and methods to measure the “state-of-health” of operating cells and stacks are becoming of increasing interest. This requires applica...... out at a range of ac perturbation amplitudes in order to investigate linearity of the response and the signal-to-noise ratio. Separation of the measured impedance into series and polarisation resistances was possible....... to analyse in detail. Today one is forced to use mathematical modelling to extract information about existing gradients and cell resistances in operating stacks, as mature techniques for local probing are not available. This type of spatially resolved information is essential for model refinement...... and validation, and helps to further the technological stack development. Further, more detailed information obtained from operating stacks is essential for developing appropriate process monitoring and control protocols for stack and system developers. An experimental stack with low ohmic resistance from Topsoe...

  2. Systems and methods for managing shared-path instrumentation and irradiation targets in a nuclear reactor

    Science.gov (United States)

    Heinold, Mark R.; Berger, John F.; Loper, Milton H.; Runkle, Gary A.

    2015-12-29

    Systems and methods permit discriminate access to nuclear reactors. Systems provide penetration pathways to irradiation target loading and offloading systems, instrumentation systems, and other external systems at desired times, while limiting such access during undesired times. Systems use selection mechanisms that can be strategically positioned for space sharing to connect only desired systems to a reactor. Selection mechanisms include distinct paths, forks, diverters, turntables, and other types of selectors. Management methods with such systems permits use of the nuclear reactor and penetration pathways between different systems and functions, simultaneously and at only distinct desired times. Existing TIP drives and other known instrumentation and plant systems are useable with access management systems and methods, which can be used in any nuclear plant with access restrictions.

  3. Mixed-methods study to develop a patient complexity assessment instrument for district nurses.

    Science.gov (United States)

    Thomas, Susan J; Wallace, Carolyn; Jarvis, Paul; Davis, Ruth Elizabeth

    2016-03-01

    There is increasing reference to complex patient needs in health care. However, little is known about how to measure patient complexity or the relationship between it and district nursing activity. To illustrate the use of group concept mapping (GCM) to conceptualise and develop items for a patient complexity assessment instrument to be used by district nurses. The first phase of this research used GCM conceptualisation and consensus methodology to identify items for a community-based patient complexity instrument. GCM helped to provide a conceptual understanding of community-based patient complexity through focused exploration of the term. indicated that a number of environmental, sociological, psychological, behavioural, physical and organisational factors needed to be included. This, in turn, showed that an existing taxonomy did not contain the relevant items. Consequently, amendments were made and a new instrument developed. GCM is a suitable consensus method for use in nursing theory and developing instruments. It proved successful in achieving consensus with no loss of participants' views. GCM is a suitable method for nurses to use in research or practice development activities as it is based on a facilitative and engagement-led approach.

  4. An ergonomics based design research method for the arrangement of helicopter flight instrument panels.

    Science.gov (United States)

    Alppay, Cem; Bayazit, Nigan

    2015-11-01

    In this paper, we study the arrangement of displays in flight instrument panels of multi-purpose civil helicopters following a user-centered design method based on ergonomics principles. Our methodology can also be described as a user-interface arrangement methodology based on user opinions and preferences. This study can be outlined as gathering user-centered data using two different research methods and then analyzing and integrating the collected data to come up with an optimal instrument panel design. An interview with helicopter pilots formed the first step of our research. In that interview, pilots were asked to provide a quantitative evaluation of basic interface arrangement principles. In the second phase of the research, a paper prototyping study was conducted with same pilots. The final phase of the study entailed synthesizing the findings from interviews and observational studies to formulate an optimal flight instrument arrangement methodology. The primary results that we present in our paper are the methodology that we developed and three new interface arrangement concepts, namely relationship of inseparability, integrated value and locational value. An optimum instrument panel arrangement is also proposed by the researchers. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  5. Intercomparison of two comparative reactivity method instruments inf the Mediterranean basin during summer 2013

    Science.gov (United States)

    Zannoni, N.; Dusanter, S.; Gros, V.; Sarda Esteve, R.; Michoud, V.; Sinha, V.; Locoge, N.; Bonsang, B.

    2015-09-01

    The hydroxyl radical (OH) plays a key role in the atmosphere, as it initiates most of the oxidation processes of volatile organic compounds (VOCs), and can ultimately lead to the formation of ozone and secondary organic aerosols (SOAs). There are still uncertainties associated with the OH budget assessed using current models of atmospheric chemistry and direct measurements of OH sources and sinks have proved to be valuable tools to improve our understanding of the OH chemistry. The total first order loss rate of OH, or total OH reactivity, can be directly measured using three different methods, such as the following: total OH loss rate measurement, laser-induced pump and probe technique and comparative reactivity method. Observations of total OH reactivity are usually coupled to individual measurements of reactive compounds in the gas phase, which are used to calculate the OH reactivity. Studies using the three methods have highlighted that a significant fraction of OH reactivity is often not explained by individually measured reactive compounds and could be associated to unmeasured or unknown chemical species. Therefore accurate and reproducible measurements of OH reactivity are required. The comparative reactivity method (CRM) has demonstrated to be an advantageous technique with an extensive range of applications, and for this reason it has been adopted by several research groups since its development. However, this method also requires careful corrections to derive ambient OH reactivity. Herein we present an intercomparison exercise of two CRM instruments, CRM-LSCE (Laboratoire des Sciences du Climat et de l'Environnement) and CRM-MD (Mines Douai), conducted during July 2013 at the Mediterranean site of Ersa, Cape Corsica, France. The intercomparison exercise included tests to assess the corrections needed by the two instruments to process the raw data sets as well as OH reactivity observations. The observation was divided in three parts: 2 days of plant

  6. Energy Expenditure of Sport Stacking

    Science.gov (United States)

    Murray, Steven R.; Udermann, Brian E.; Reineke, David M.; Battista, Rebecca A.

    2009-01-01

    Sport stacking is an activity taught in many physical education programs. The activity, although very popular, has been studied minimally, and the energy expenditure for sport stacking is unknown. Therefore, the purposes of this study were to determine the energy expenditure of sport stacking in elementary school children and to compare that value…

  7. OpenStack cloud security

    CERN Document Server

    Locati, Fabio Alessandro

    2015-01-01

    If you are an OpenStack administrator or developer, or wish to build solutions to protect your OpenStack environment, then this book is for you. Experience of Linux administration and familiarity with different OpenStack components is assumed.

  8. A multi-criteria evaluation method for climate change mitigation policy instruments

    International Nuclear Information System (INIS)

    Konidari, Popi; Mavrakis, Dimitrios

    2007-01-01

    This paper presents an integrated multi-criteria analysis method for the quantitative evaluation of climate change mitigation policy instruments. The method consists of: (i) a set of criteria supported by sub-criteria, all of which describe the complex framework under which these instruments are selected by policy makers and implemented, (ii) an Analytical Hierarchy Process (AHP) process for defining weight coefficients for criteria and sub-criteria according to the preferences of three stakeholders groups and (iii) a Multi-Attribute Theory (MAUT)/Simple Multi-Attribute Ranking Technique (SMART) process for assigning grades to each instrument that is evaluated for its performance under a specific sub-criterion. Arguments for the selected combination of these standard methods and definitions for criteria/sub-criteria are quoted. Consistency and robustness tests are performed. The functionality of the proposed method is tested by assessing the aggregate performances of the EU emission trading scheme at Denmark, Germany, Greece, Italy, Netherlands, Portugal, Sweden and United Kingdom. Conclusions are discussed

  9. TRIANGULATION OF INSTRUMENTATION AND DATA SOURCE: A STRONGER METHOD IN ASSESSING ENGLISH LANGUAGE NEEDS

    Directory of Open Access Journals (Sweden)

    Meedy Nugraha

    2002-01-01

    Full Text Available This paper proposes the importance of multiple instrumentation and data source (triangulation in a needs analysis. Various data gathering methods developed in assessing learners' English language needs are reviewed. The justification of employing more than a single data gathering method and data source in a needs analysis is also presented by examining the strengths and weaknesses of each method and evaluating previous needs analyses carried out in some Asian countries. Highlights are then given to the methodology mostly implemented in assessing English needs in Indonesia and a recommendation is addressed to further studies on learners's needs in Indonesia

  10. Bayesian methods for meta-analysis of causal relationships estimated using genetic instrumental variables

    DEFF Research Database (Denmark)

    Burgess, Stephen; Thompson, Simon G; Thompson, Grahame

    2010-01-01

    Genetic markers can be used as instrumental variables, in an analogous way to randomization in a clinical trial, to estimate the causal relationship between a phenotype and an outcome variable. Our purpose is to extend the existing methods for such Mendelian randomization studies to the context...... an overall estimate of the causal relationship between the phenotype and the outcome, and an assessment of its heterogeneity across studies. As an example, we estimate the causal relationship of blood concentrations of C-reactive protein on fibrinogen levels using data from 11 studies. These methods provide...... a flexible framework for efficient estimation of causal relationships derived from multiple studies. Issues discussed include weak instrument bias, analysis of binary outcome data such as disease risk, missing genetic data, and the use of haplotypes....

  11. Precision of GNSS instruments by static method comparing in real time

    Directory of Open Access Journals (Sweden)

    Slavomír Labant

    2009-09-01

    Full Text Available Tablet paper describes comparison of measuring accuracy two apparatus from the firm Leica. One of them recieve signals onlyfrom GPS satelites and another instrument is working with GPS and also with GLONASS satelites. Measuring is carry out by RTK staticmethod with 2 minutes observations. Measurement processing is separated to X, Y (position and h (heigh. Adjustment of directobservations is used as a adjusting method.

  12. Evaluation of hydrogen embrittlement and temper embrittlement by key curve method in instrumented Charpy test

    OpenAIRE

    Makita A.; Shindo Y.; Ohtsuka N.

    2010-01-01

    Instrumented Charpy test was conducted on small sized specimen of 21/4Cr-1Mo steel. In the test the single specimen key curve method was applied to determine the value of fracture toughness for the initiation of crack extension with hydrogen free, KIC, and for hydrogen embrittlement cracking, KIH. Also the tearing modulus as a parameter for resistance to crack extension was determined. The role of these parameters was discussed at an upper shelf temperature and at a transition temperat...

  13. INSTRUMENTS AND METHODS OF INVESTIGATION: Invisible cloaking of material bodies using the wave flow method

    Science.gov (United States)

    Dubinov, Alexander E.; Mytareva, Lyubov'A.

    2010-08-01

    The current knowledge of the physics of electromagnetic cloaking of material objects by the wave flow method is reviewed. Experiments demonstrating the feasibility of this cloaking method are described. Some aspects of calculating cloak profiles are examined, and achievements and unsolved problems in the theory of the interaction of electromagnetic waves with shells are considered. Prospects for developing the cloaking method for waves of other physical nature (acoustic and probability density waves) are discussed.

  14. Contemporary sample stacking in analytical electrophoresis.

    Science.gov (United States)

    Malá, Zdena; Šlampová, Andrea; Křivánková, Ludmila; Gebauer, Petr; Boček, Petr

    2015-01-01

    This contribution is a methodological review of the publications about the topic from the last 2 years. Therefore, it is primarily organized according to the methods and procedures used in surveyed papers and the origin and type of sample and specification of analytes form the secondary structure. The introductory part about navigation in the architecture of stacking brings a brief characterization of the various stacking methods, with the description of mutual links to each other and important differences among them. The main body of the article brings a survey of publications organized according to main principles of stacking and then according to the origin and type of the sample. Provided that the paper cited gave explicitly the relevant data, information about the BGE(s) used, procedure, detector employed, and reached LOD and/or concentration effect is given. The papers where the procedure used is a combination of diverse fragments and parts of various stacking techniques are mentioned in a special section on combined techniques. The concluding remarks in the final part of the review evaluate present state of art and the trends of sample stacking in CE. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Stack Caching Using Split Data Caches

    DEFF Research Database (Denmark)

    Nielsen, Carsten; Schoeberl, Martin

    2015-01-01

    In most embedded and general purpose architectures, stack data and non-stack data is cached together, meaning that writing to or loading from the stack may expel non-stack data from the data cache. Manipulation of the stack has a different memory access pattern than that of non-stack data, showing...... higher temporal and spatial locality. We propose caching stack and non-stack data separately and develop four different stack caches that allow this separation without requiring compiler support. These are the simple, window, and prefilling with and without tag stack caches. The performance of the stack...

  16. Unexpected but Most Welcome: Mixed Methods for the Validation and Revision of the Participatory Evaluation Measurement Instrument

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve

    2014-01-01

    Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…

  17. A method for automating calibration and records management for instrumentation and dosimetry

    International Nuclear Information System (INIS)

    O'Brien, J.M. Jr.; Rushton, R.O.; Burns, R.E. Jr.

    1993-01-01

    Current industry requirements are becoming more stringent on quality assurance records and documentation for calibration of instruments and dosimetry. A novel method is presented here that will allow a progressive automation scheme to be used in pursuit of that goal. This concept is based on computer-controlled irradiators that can act as stand-alone devices or be interfaced to other components via a computer local area network. In this way, complete systems can be built with modules to create a records management system to meet the needs of small laboratories or large multi-building calibration groups. Different database engines or formats can be used simply by replacing a module. Modules for temperature and pressure monitoring or shipping and receiving can be added, as well as equipment modules for direct IEEE-488 interface to electrometers and other instrumentation

  18. Reliability of the input admittance of bowed-string instruments measured by the hammer method.

    Science.gov (United States)

    Zhang, Ailin; Woodhouse, Jim

    2014-12-01

    The input admittance at the bridge, measured by hammer testing, is often regarded as the most useful and convenient measurement of the vibrational behavior of a bowed string instrument. However, this method has been questioned, due especially to differences between human bowing and hammer impact. The goal of the research presented here is to investigate the reliability and accuracy of this classic hammer method. Experimental studies were carried out on cellos, with three different driving conditions and three different boundary conditions. Results suggest that there is nothing fundamentally different about the hammer method, compared to other kinds of excitation. The third series of experiments offers an opportunity to explore the difference between the input admittance measuring from one bridge corner to another and that of single strings. The classic measurement is found to give a reasonable approximation to that of all four strings. Some possible differences between the hammer method and normal bowing and implications of the acoustical results are also discussed.

  19. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  20. Forced Air-Breathing PEMFC Stacks

    Directory of Open Access Journals (Sweden)

    K. S. Dhathathreyan

    2012-01-01

    Full Text Available Air-breathing fuel cells have a great potential as power sources for various electronic devices. They differ from conventional fuel cells in which the cells take up oxygen from ambient air by active or passive methods. The air flow occurs through the channels due to concentration and temperature gradient between the cell and the ambient conditions. However developing a stack is very difficult as the individual cell performance may not be uniform. In order to make such a system more realistic, an open-cathode forced air-breathing stacks were developed by making appropriate channel dimensions for the air flow for uniform performance in a stack. At CFCT-ARCI (Centre for Fuel Cell Technology-ARC International we have developed forced air-breathing fuel cell stacks with varying capacity ranging from 50 watts to 1500 watts. The performance of the stack was analysed based on the air flow, humidity, stability, and so forth, The major advantage of the system is the reduced number of bipolar plates and thereby reduction in volume and weight. However, the thermal management is a challenge due to the non-availability of sufficient air flow to remove the heat from the system during continuous operation. These results will be discussed in this paper.

  1. Instrumental methods and techniques for structural and physicochemical characterization of biomaterials and bone tissue: A review.

    Science.gov (United States)

    Mitić, Žarko; Stolić, Aleksandra; Stojanović, Sanja; Najman, Stevo; Ignjatović, Nenad; Nikolić, Goran; Trajanović, Miroslav

    2017-10-01

    A review of recent advances in instrumental methods and techniques for structural and physicochemical characterization of biomaterials and bone tissue is presented in this paper. In recent years, biomaterials attracted great attention primarily because of the wide range of biomedical applications. This paper focuses on the practical aspects of instrumental methods and techniques that were most often applied (X-ray methods, vibrational spectroscopy (IR and Raman), magnetic-resonance spectroscopy (NMR and ESR), mass spectrometry (MS), atomic absorption spectrometry (AAS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES), thermogravimetry (TG), differential thermal analysis (DTA) and differential scanning calorimetry (DSC), scanning electron microscopy (SEM), transmission electron microscopy (TEM)) in the structural investigation and physicochemical characterization of biomaterials and bone tissue. The application of some other physicochemical methods was also discussed. Hands-on information is provided about these valuable research tools, emphasizing practical aspects such as typical measurement conditions, their limitations and advantages, interpretation of results and practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A postprocessing method in the HMC framework for predicting gene function based on biological instrumental data

    Science.gov (United States)

    Feng, Shou; Fu, Ping; Zheng, Wenbin

    2018-03-01

    Predicting gene function based on biological instrumental data is a complicated and challenging hierarchical multi-label classification (HMC) problem. When using local approach methods to solve this problem, a preliminary results processing method is usually needed. This paper proposed a novel preliminary results processing method called the nodes interaction method. The nodes interaction method revises the preliminary results and guarantees that the predictions are consistent with the hierarchy constraint. This method exploits the label dependency and considers the hierarchical interaction between nodes when making decisions based on the Bayesian network in its first phase. In the second phase, this method further adjusts the results according to the hierarchy constraint. Implementing the nodes interaction method in the HMC framework also enhances the HMC performance for solving the gene function prediction problem based on the Gene Ontology (GO), the hierarchy of which is a directed acyclic graph that is more difficult to tackle. The experimental results validate the promising performance of the proposed method compared to state-of-the-art methods on eight benchmark yeast data sets annotated by the GO.

  3. Passive stack ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, J.; Parkins, L.; Shaw, P.; Watkins, R. [Databuild, Birmingham (United Kingdom)

    1994-12-31

    The adequate ventilation of houses is essential for both the occupants and the building fabric. As air-tightness standards increase, background infiltration levels decrease and extra ventilation has to be designed into the building. Passive stack ventilation has many advantages - particularly when employed in low cost housing schemes -but it is essential that it performs satisfactorily. This paper give the results from monitoring two passive stack ventilation schemes. One scheme was a retrofit into refurbished local authority houses in which a package of energy efficiency measures had been taken and condensation had been a problem. The other series of tests were conducted on a new installation in a Housing Association development. Nine houses were monitored each of which had at least two passive vents. The results show air flow rates by the passive ducts equivalent to approximately 1 room air change per hour. The air flow in the ducts was influenced by both, internal to external temperature difference and wind speed and direction. (author)

  4. Using qualitative methods to develop a contextually tailored instrument: Lessons learned.

    Science.gov (United States)

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C

    2015-01-01

    To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations.

  5. Evaluation of Beeswax Influence on Physical Properties of Lipstick Using Instrumental and Sensory Methods

    Directory of Open Access Journals (Sweden)

    Giedre Kasparaviciene

    2016-01-01

    Full Text Available The aim of this study was to optimize the lipsticks formulation according to the physical properties and sensory attributes and investigate the relationship between instrumental and sensory analyses and evaluate the influence of the main ingredients, beeswax and oil, with analysis of lipsticks properties. Central composite design was used to optimize the mixture of oils and beeswax and cocoa butter for formulation of lipsticks. Antioxidant activity was evaluated by DPPH free radical scavenging method spectrophotometrically. Physical properties of lipsticks melting point were determined in a glass tube; the hardness was investigated with texture analyzer. Sensory analysis was performed with untrained volunteers. The optimized mixture of sea buckthorn oil and grapeseed oil mixture ratio 13.96 : 6.18 showed the highest antioxidative activity (70±0.84% and was chosen for lipstick formulation. According to the sensory and instrumental analysis results, optimal ingredients amounts for the lipstick were calculated: 57.67% mixture of oils, 19.58% beeswax, and 22.75% cocoa butter. Experimentally designed and optimized lipstick formulation had good physical properties and high scored sensory evaluation. Correlation analysis showed a significant relationship between sensory and instrumental evaluations.

  6. Improved retrieval of cloud base heights from ceilometer using a non-standard instrument method

    Science.gov (United States)

    Wang, Yang; Zhao, Chuanfeng; Dong, Zipeng; Li, Zhanqing; Hu, Shuzhen; Chen, Tianmeng; Tao, Fa; Wang, Yuzhao

    2018-04-01

    Cloud-base height (CBH) is a basic cloud parameter but has not been measured accurately, especially under polluted conditions due to the interference of aerosol. Taking advantage of a comprehensive field experiment in northern China in which a variety of advanced cloud probing instruments were operated, different methods of detecting CBH are assessed. The Micro-Pulse Lidar (MPL) and the Vaisala ceilometer (CL51) provided two types of backscattered profiles. The latter has been employed widely as a standard means of measuring CBH using the manufacturer's operational algorithm to generate standard CBH products (CL51 MAN) whose quality is rigorously assessed here, in comparison with a research algorithm that we developed named value distribution equalization (VDE) algorithm. It was applied to both the profiles of lidar backscattering data from the two instruments. The VDE algorithm is found to produce more accurate estimates of CBH for both instruments and can cope with heavy aerosol loading conditions well. By contrast, CL51 MAN overestimates CBH by 400 m and misses many low level clouds under such conditions. These findings are important given that CL51 has been adopted operationally by many meteorological stations in China.

  7. Evaluation of Beeswax Influence on Physical Properties of Lipstick Using Instrumental and Sensory Methods.

    Science.gov (United States)

    Kasparaviciene, Giedre; Savickas, Arunas; Kalveniene, Zenona; Velziene, Saule; Kubiliene, Loreta; Bernatoniene, Jurga

    2016-01-01

    The aim of this study was to optimize the lipsticks formulation according to the physical properties and sensory attributes and investigate the relationship between instrumental and sensory analyses and evaluate the influence of the main ingredients, beeswax and oil, with analysis of lipsticks properties. Central composite design was used to optimize the mixture of oils and beeswax and cocoa butter for formulation of lipsticks. Antioxidant activity was evaluated by DPPH free radical scavenging method spectrophotometrically. Physical properties of lipsticks melting point were determined in a glass tube; the hardness was investigated with texture analyzer. Sensory analysis was performed with untrained volunteers. The optimized mixture of sea buckthorn oil and grapeseed oil mixture ratio 13.96 : 6.18 showed the highest antioxidative activity (70 ± 0.84%) and was chosen for lipstick formulation. According to the sensory and instrumental analysis results, optimal ingredients amounts for the lipstick were calculated: 57.67% mixture of oils, 19.58% beeswax, and 22.75% cocoa butter. Experimentally designed and optimized lipstick formulation had good physical properties and high scored sensory evaluation. Correlation analysis showed a significant relationship between sensory and instrumental evaluations.

  8. An algorithm for a valved brass instrument synthesis environment using finite-difference time-domain methods with performance optimisation

    OpenAIRE

    Harrison, Reginald L.; Bilbao, Stefan; Perry, James

    2015-01-01

    This paper presents a physical modelling sound synthesis environment for the production of valved brass instrument sounds. The governing equations of the system are solved using finite-difference time-domain (FDTD) methods and the environment is implemented in the C programming language. Users of the environment can create their own custom instruments and are able to control player parameters such as lip frequency, mouth pressure and valve openings through the use of instrument and score file...

  9. Instrumental method for determination of nitrogen and fluorine in plutonium using (α, pγ) reaction

    International Nuclear Information System (INIS)

    Ovechkin, V.V.; Melent'ev, V.I.; Gorbunov, V.F.

    1976-01-01

    The instrumental method of determining nitrogen and fluorine in 239 Pu has been developed which is based on measuring the areas of peaks of γ-radiation with energy 871 keV (for nitrogen) and 1275 KeV (for fluorine) with respect to the peak areas of 239 Pu γ-self-radiation. The lower limits for nitrogen and fluorine detection equal to 5.10 -3 and 3x10 -3 wt.%, respectively, have been attained when analysing 5g plutonium sample for 2 hours with the help of γ-spectrometer

  10. Design and manufacturing methods for the integral field unit of the nirspec instrument on JWST

    Science.gov (United States)

    Lobb, Dan; Robertson, David

    2017-11-01

    An integral field unit, to be used with the near-IR spectrometer instrument of the James Webb Space Telescope (JWST), is currently under development by SSTL and CfAI. Special problems in design and manufacture of the optical system are outlined, and manufacturing methods for critical optical elements are discussed. The optical system is complex, requiring a total of 95 mirrors to produce 30 output channels. Emphasis is placed on the advantages of free-form machining in aluminium. These include: resistance to launch stress, insensitivity to temperature variations from ambient to cryogenic, and the possibility of relatively complex mirror surface shapes.

  11. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  12. A Method of Separation Assurance for Instrument Flight Procedures at Non-Radar Airports

    Science.gov (United States)

    Conway, Sheila R.; Consiglio, Maria

    2002-01-01

    A method to provide automated air traffic separation assurance services during approach to or departure from a non-radar, non-towered airport environment is described. The method is constrained by provision of these services without radical changes or ambitious investments in current ground-based technologies. The proposed procedures are designed to grant access to a large number of airfields that currently have no or very limited access under Instrument Flight Rules (IFR), thus increasing mobility with minimal infrastructure investment. This paper primarily addresses a low-cost option for airport and instrument approach infrastructure, but is designed to be an architecture from which a more efficient, albeit more complex, system may be developed. A functional description of the capabilities in the current NAS infrastructure is provided. Automated terminal operations and procedures are introduced. Rules of engagement and the operations are defined. Results of preliminary simulation testing are presented. Finally, application of the method to more terminal-like operations, and major research areas, including necessary piloted studies, are discussed.

  13. [Study on a new method for instrumental line shape measurement of spatial heterodyne interference spectrometer].

    Science.gov (United States)

    Xiong, Wei; Shi, Hai-liang; Yu, Neng-hai

    2015-01-01

    Spatial heterodyne spectroscopy(SHS)is a novel method for hyper-spectral analysis, and instrument line shape function is one of the basic performance parameters, which should be precisely characterized. Based on the analysis of the influence factors(apodization, limited angle, abaxial detector element) and special requirement for measuring method and source, the present paper put forward a new method for measuring with tunable monochromatic light source, and designed experimental equipment with tunable laser and integrating sphere eliminating speckle. Selecting typical spectral range within band range for high spectral resolution scanning (0. 1nm step), the energy distribution of spectrum was obtained according to error correction, spectral reconstruction and normalization. In addition, rule curve for FWHM and wavelength was obtained by the full spectral range scanning interferogram. Finally, theoretical spectrum, ILS convolution simulated spectrum (LBL calculated), and measured carbon dioxide absorption spectrum by ground-based experiment are in good agreement. The result shows that the instrument line shape function exhibits high accuracy.

  14. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  15. A quality control method for nuclear instrumentation and control systems based on software safety prediction

    Science.gov (United States)

    Son, Han Seong; Seong, Poong Hyun

    2000-04-01

    In the case of safety-related applications like nuclear instrumentation and control (NI&C), safety-oriented quality control is required. The objective of this paper is to present a software safety classification method as a safety-oriented quality control tool. Based on this method, we predict the risk (and thus safety) of software items that are at the core of NI&C systems. Then we classify the software items according to the degree of the risk. The method can be used earlier than at the detailed design phase. Furthermore, the method can also be used in all the development phases without major changes. The proposed method seeks to utilize the measures that can be obtained from the safety analysis and requirements analysis. Using the measures proved to be desirable in a few aspects. The authors have introduced fuzzy approximate reasoning to the classification method because experts' knowledge covers the vague frontiers between good quality and bad quality with linguistic uncertainty and fuzziness. Fuzzy Colored Petri Net (FCPN) is introduced in order to offer a formal framework for the classification method and facilitate the knowledge representation, modification, or verification. Through the proposed quality control method, high-quality NI&C systems can be developed effectively and used safely.

  16. Reflector imaging by diffraction stacking with stacking velocity analysis; Jugo sokudo kaiseki wo tomonau sanran jugoho ni yoru hanshamen imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, J.; Rokugawa, S.; Kato, Y. [The University of Tokyo, Tokyo (Japan). Faculty of Engineering; Yokota, T. [Japan National Oil Corp., Tokyo (Japan); Miyazaki, T. [Geological Survey of Japan, Tsukuba (Japan)

    1997-10-22

    Concerning seismic reflection survey for geometrical arrangement between pits, the scattering stacking method with stacking velocity analysis is compared with the CDP (common depth point horizontal stacking method). The advantages of the CDP supposedly include the following. Since it presumes an average velocity field, it can determine velocities having stacking effects. The method presumes stratification and, since such enables the division of huge quantities of observed data into smaller groups, more data can be calculated in a shorter time period. The method has disadvantages, attributable to its presuming an average velocity field, that accuracy in processing is lower when the velocity field contrast is higher, that accuracy in processing is low unless stratification is employed, and that velocities obtained from stacking velocity analysis are affected by dipped structures. Such shortcomings may be remedied in the scattering stacking method with stacking velocity analysis. Possibilities are that, as far as the horizontal reflection plane is concerned, it may yield stack records higher in S/N ratio than the CDP. Findings relative to dipped reflection planes will be introduced at the presentation. 6 refs., 12 figs.

  17. Calculation of AC losses in large HTS stacks and coils

    DEFF Research Database (Denmark)

    Zermeno, Victor; Abrahamsen, Asger Bech; Mijatovic, Nenad

    2012-01-01

    In this work, we present a homogenization method to model a stack of HTS tapes under AC applied transport current or magnetic field. The idea is to find an anisotropic bulk equivalent for the stack of tapes, where the internal alternating structures of insulating, metallic, superconducting and su...

  18. A method for retrieving endodontic or atypical nonendodontic separated instruments from the root canal: a report of two cases.

    Science.gov (United States)

    Monteiro, Jardel Camilo do Carmo; Kuga, Milton Carlos; Dantas, Andrea Abi Rached; Jordão-Basso, Keren Cristina Fagundes; Keine, Katia Cristina; Ruchaya, Prashant Jay; Faria, Gisele; Leonardo, Renato de Toledo

    2014-11-01

    This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

  19. Optical Testing and Verification Methods for the James Webb Space Telescope Integrated Science Instrument Module Element

    Science.gov (United States)

    Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.; hide

    2016-01-01

    NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (40K). The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) that contains four science instruments (SI) and the fine guider. The SIs are mounted to a composite metering structure. The SI and guider units were integrated to the ISIM structure and optically tested at the NASA Goddard Space Flight Center as a suite using the Optical Telescope Element SIMulator (OSIM). OSIM is a full field, cryogenic JWST telescope simulator. SI performance, including alignment and wave front error, were evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.

  20. A method of estimating GPS instrumental biases with a convolution algorithm

    Science.gov (United States)

    Li, Qi; Ma, Guanyi; Lu, Weijun; Wan, Qingtao; Fan, Jiangtao; Wang, Xiaolan; Li, Jinghua; Li, Changhua

    2018-03-01

    This paper presents a method of deriving the instrumental differential code biases (DCBs) of GPS satellites and dual frequency receivers. Considering that the total electron content (TEC) varies smoothly over a small area, one ionospheric pierce point (IPP) and four more nearby IPPs were selected to build an equation with a convolution algorithm. In addition, unknown DCB parameters were arranged into a set of equations with GPS observations in a day unit by assuming that DCBs do not vary within a day. Then, the DCBs of satellites and receivers were determined by solving the equation set with the least-squares fitting technique. The performance of this method is examined by applying it to 361 days in 2014 using the observation data from 1311 GPS Earth Observation Network (GEONET) receivers. The result was crosswise-compared with the DCB estimated by the mesh method and the IONEX products from the Center for Orbit Determination in Europe (CODE). The DCB values derived by this method agree with those of the mesh method and the CODE products, with biases of 0.091 ns and 0.321 ns, respectively. The convolution method's accuracy and stability were quite good and showed improvements over the mesh method.

  1. Instant BlueStacks

    CERN Document Server

    Judge, Gary

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A fast-paced, example-based approach guide for learning BlueStacks.This book is for anyone with a Mac or PC who wants to run Android apps on their computer. Whether you want to play games that are freely available for Android but not your computer, or you want to try apps before you install them on a physical device or use it as a development tool, this book will show you how. No previous experience is needed as this is written in plain English

  2. An adaptive and fully automatic method for estimating the 3D position of bendable instruments using endoscopic images.

    Science.gov (United States)

    Cabras, Paolo; Nageotte, Florent; Zanne, Philippe; Doignon, Christophe

    2017-12-01

    Flexible bendable instruments are key tools for performing surgical endoscopy. Being able to measure the 3D position of such instruments can be useful for various tasks, such as controlling automatically robotized instruments and analyzing motions. An automatic method is proposed to infer the 3D pose of a single bending section instrument, using only the images provided by a monocular camera embedded at the tip of the endoscope. The proposed method relies on colored markers attached onto the bending section. The image of the instrument is segmented using a graph-based method and the corners of the markers are extracted by detecting the color transitions along Bézier curves fitted on edge points. These features are accurately located and then used to estimate the 3D pose of the instrument using an adaptive model that takes into account the mechanical play between the instrument and its housing channel. The feature extraction method provides good localization of marker corners with images of the in vivo environment despite sensor saturation due to strong lighting. The RMS error on estimation of the tip position of the instrument for laboratory experiments was 2.1, 1.96, and 3.18 mm in the x, y and z directions, respectively. Qualitative analysis in the case of in vivo images shows the ability to correctly estimate the 3D position of the instrument tip during real motions. The proposed method provides an automatic and accurate estimation of the 3D position of the tip of a bendable instrument in realistic conditions, where standard approaches fail. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Workshop on future instruments for nuclear and particle physics and methods at the FRM-II

    International Nuclear Information System (INIS)

    Neuhaus, J.

    2002-01-01

    Conference report: The 'Workshop on Future Instruments for Nuclear and Particle Physics and Methods' at the FRM-II took place on April 12th, 2002 in Garching. The scope of the workshop was to bring together different groups of interest in the field of nuclear and particle physics as well as nuclear methods in view of the future experimental facilities at the new German neutron source FRM-II. Besides the conventional neutron sources, the FRM-II will provide new sources for neutron rich fission fragments, positrons and ultra cold neutrons. They will extend intensities from existing sources by orders of magnitude. Throughout the workshop the speakers pointed out the urgent need to start the operation of the FRM-II immediately in order not to lose this unique advantage. (orig.)

  4. A novel single-step, multipoint calibration method for instrumented Lab-on-Chip systems

    DEFF Research Database (Denmark)

    Pfreundt, Andrea; Patou, François; Zulfiqar, Azeem

    2014-01-01

    Despite recent and substantial advances in biosensing, information and communication, and Lab-on-Chip (LoC) technologies, the success of Point-of-Care (PoC) diagnostics and monitoring systems is still challenged by stringent requirements for robustness, cost-effectiveness, and system integration....... The pitfalls of PoC system adoption can be addressed early in the system design phase. They require a multidisciplinary design approach supported by systems engineering tools and methods. Considering this, we here present both a model and an implementation of a simple and rapid calibration scheme...... for instrument-based PoC blood biomarker analysis systems. Motivated by the complexity of associating high-accuracy biosensing using silicon nanowire field effect transistors with ease of use for the PoC system user, we propose a novel one-step, multipoint calibration method for LoC-based systems. Our approach...

  5. A comparison of different methods for improving flux and resolution on SANS instruments

    International Nuclear Information System (INIS)

    Littrell, K.C.

    2004-01-01

    Small-angle neutron scattering (SANS) is one of the most popular and oversubscribed techniques at every user facility for neutron scattering studies of condensed matter that offers it. The limiting features in SANS experiment design are the length of time required to make a measurement and the minimum momentum transfer Q that can be measured, and the resolution. In the traditional pinhole-camera geometry, these two constraints are inextricably linked, forcing tradeoffs. However, a number of methods have been developed for reducing this linkage, thus allowing higher throughput while retaining high resolution and a low minimum Q. These methods include using multiple confocal pinhole apertures, lenses, and focusing mirrors. We compare and contrast these options and discuss their suitability for use on instruments at pulsed neutron sources

  6. SANS contrast variation method applied in experiments on ferrofluids at MURN instrument of IBR-2 reactor

    Science.gov (United States)

    Balasoiu, Maria; Kuklin, Alexander

    2012-03-01

    Separate determination of the nuclear and magnetic contributions to the scattering intensity by means of a contrast variation method applied in a small angle neutron scattering experiment of nonpolarized neutrons in ferrofluids in early 90 's at the MURN instrument is reviewed. The nuclear scattering contribution gives the features of the colloidal particle dimensions, surfactant shell structure and the solvent degree penetration to the macromolecular layer. The magnetic scattering part is compatible to the models where is supposed that the particle surface has a nonmagnetic layer. Details on experimental "Grabcev method" in obtaining separate nuclear and magnetic contributions to the small angle neutron scattering intensity of unpolarized neutrons are emphasized for the case of a high quality ultrastabile benzene-based ferrofluid with magnetite nanoparticles.

  7. SANS contrast variation method applied in experiments on ferrofluids at MURN instrument of IBR-2 reactor

    International Nuclear Information System (INIS)

    Balasoiu, Maria; Kuklin, Alexander

    2012-01-01

    Separate determination of the nuclear and magnetic contributions to the scattering intensity by means of a contrast variation method applied in a small angle neutron scattering experiment of nonpolarized neutrons in ferrofluids in early 90 's at the MURN instrument is reviewed. The nuclear scattering contribution gives the features of the colloidal particle dimensions, surfactant shell structure and the solvent degree penetration to the macromolecular layer. The magnetic scattering part is compatible to the models where is supposed that the particle surface has a nonmagnetic layer. Details on experimental 'Grabcev method' in obtaining separate nuclear and magnetic contributions to the small angle neutron scattering intensity of unpolarized neutrons are emphasized for the case of a high quality ultrastabile benzene-based ferrofluid with magnetite nanoparticles.

  8. A new method for the radiation representation of musical instruments in auralizations

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    A new method for the representation of sound sources that vary their directivity in time in auralizations is introduced. A recording method with multi-channel anechoic recordings is proposed in connection with the use of a multiple virtual source reproduction system in auralizations. Listening ex...... to be significant. Further applications of the method are considered for ensembles within room auralizations as well as in the field of studio recording techniques for large instruments.......A new method for the representation of sound sources that vary their directivity in time in auralizations is introduced. A recording method with multi-channel anechoic recordings is proposed in connection with the use of a multiple virtual source reproduction system in auralizations. Listening...... experiments designed to validate the quality of the reproduction method compared with a fixed directivity representation have showed that there is a clear improvement in the timbral quality of the sound reproduced. The improvement represented by the system regarding the spaciousness of sound did not prove...

  9. Comparison of neutron activation analysis with other instrumental methods for elemental analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Regge, P. de; Lievens, F.; Delespaul, I.; Monsecour, M.

    1976-01-01

    A comparison of instrumental methods, including neutron activation analysis, X-ray fluorescence spectrometry, atomic absorption spectrometry and emission spectrometry, for the analysis of heavy metals in airborne particulate matter is described. The merits and drawbacks of each method for the routine analysis of a large number of samples are discussed. The sample preparation technique, calibration and statistical data relevant to each method are given. Concordant results are obtained by the different methods for Co, Cu, Ni, Pb and Zn. Less good agreement is obtained for Fe, Mn and V. The results are not in agreement for the elements Cd and Cr. Using data obtained on the dust sample distributed by Euratom-ISPRA within the framework of an interlaboratory comparison, the accuracy of each method for the various elements is estimated. Neutron activation analysis was found to be the most sensitive and accurate of the non-destructive analysis methods. Only atomic absorption spectrometry has a comparable sensitivity, but requires considerable preparation work. X-ray fluorescence spectrometry is less sensitive and shows biases for Cr and V. Automatic emission spectrometry with simultaneous measurement of the beam intensities by photomultipliers is the fastest and most economical technique, though at the expense of some precision and sensitivity. (author)

  10. Assessing Elementary Algebra with STACK

    Science.gov (United States)

    Sangwin, Christopher J.

    2007-01-01

    This paper concerns computer aided assessment (CAA) of mathematics in which a computer algebra system (CAS) is used to help assess students' responses to elementary algebra questions. Using a methodology of documentary analysis, we examine what is taught in elementary algebra. The STACK CAA system, http://www.stack.bham.ac.uk/, which uses the CAS…

  11. HPC Software Stack Testing Framework

    Energy Technology Data Exchange (ETDEWEB)

    2017-07-27

    The HPC Software stack testing framework (hpcswtest) is used in the INL Scientific Computing Department to test the basic sanity and integrity of the HPC Software stack (Compilers, MPI, Numerical libraries and Applications) and to quickly discover hard failures, and as a by-product it will indirectly check the HPC infrastructure (network, PBS and licensing servers).

  12. Using method triangulation to validate a new instrument (CPWQ-com) assessing cancer patients' satisfaction with communication

    DEFF Research Database (Denmark)

    Ross, Lone; Lundstrøm, Louise Hyldborg; Petersen, Morten Aagaard

    2012-01-01

    Patients' perceptions of care including the communication with health care staff is recognized as an important aspect of the quality of cancer care. Using mixed methods, we developed and validated a short instrument assessing this communication....

  13. On the measurement of the stacking-fault energies of face centered cubic metal and austenitic stainless steels by X-ray diffraction

    International Nuclear Information System (INIS)

    Borges, J.F.A.

    1985-01-01

    An X-rays diffraction method was applied to measure the Stacking-Fault Energies (SFE) of the AISI 304, AISI 316, AISI 347 and DIN-WERKSTOFF 1.4970 Austenitic Stainless Steels. The SFE determination plays an important role in the research of the mechanical behaviour of the Metal and Alloys, their deformation mechanisms, stability of microstructure amd electronic configuration. The method is based on the relationship between the SFE and the ratio of the Mean Square Strain to the Stacking-Fault probability. The Mean Square Strain was evaluated by Fourier Analysis of X-rays Diffraction profiles, corrected to reduce instrumental effects, followed by the application of the Warren-Averbach method to the Fourier Coefficients. The Stacking-Fault probabilities were derived from the changes of peak separations between cold-worked and annealed specimens. (author) [pt

  14. Detailed characterizations of a Comparative Reactivity Method (CRM) instrument: experiments vs. modelling

    Science.gov (United States)

    Michoud, V.; Hansen, R. F.; Locoge, N.; Stevens, P. S.; Dusanter, S.

    2015-04-01

    The Hydroxyl radical (OH) is an important oxidant in the daytime troposphere that controls the lifetime of most trace gases, whose oxidation leads to the formation of harmful secondary pollutants such as ozone (O3) and Secondary Organic Aerosols (SOA). In spite of the importance of OH, uncertainties remain concerning its atmospheric budget and integrated measurements of the total sink of OH can help reducing these uncertainties. In this context, several methods have been developed to measure the first-order loss rate of ambient OH, called total OH reactivity. Among these techniques, the Comparative Reactivity Method (CRM) is promising and has already been widely used in the field and in atmospheric simulation chambers. This technique relies on monitoring competitive OH reactions between a reference molecule (pyrrole) and compounds present in ambient air inside a sampling reactor. However, artefacts and interferences exist for this method and a thorough characterization of the CRM technique is needed. In this study, we present a detailed characterization of a CRM instrument, assessing the corrections that need to be applied on ambient measurements. The main corrections are, in the order of their integration in the data processing: (1) a correction for a change in relative humidity between zero air and ambient air, (2) a correction for the formation of spurious OH when artificially produced HO2 react with NO in the sampling reactor, and (3) a correction for a deviation from pseudo first-order kinetics. The dependences of these artefacts to various measurable parameters, such as the pyrrole-to-OH ratio or the bimolecular reaction rate constants of ambient trace gases with OH are also studied. From these dependences, parameterizations are proposed to correct the OH reactivity measurements from the abovementioned artefacts. A comparison of experimental and simulation results is then discussed. The simulations were performed using a 0-D box model including either (1) a

  15. Methods and instrumentation for investigating Hall sensors during their irradiation in nuclear research reactors

    International Nuclear Information System (INIS)

    Bolshakova, I.; Holyaka, R.; Makido, E.; Marusenkov, A.; Shurygin, F.; Yerashok, V.; Moreau, P. J.; Vayakis, G.; Duran, I.; Stockel, J.; Chekanov, V.; Konopleva, R.; Nazarkin, I.; Kulikov, S.; Leroy, C.

    2009-01-01

    Present work discusses the issues of creating the instrumentation for testing the semiconductor magnetic field sensors during their irradiation with neutrons in nuclear reactors up to fluences similar to neutron fluences in steady-state sensor locations in ITER. The novelty of the work consists in Hall sensor parameters being investigated: first, directly during the irradiation (in real time), and, second, at high irradiation levels (fast neutron fluence > 10 18 n/cm 2 ). Developed instrumentation has been successfully tested and applied in the research experiments on radiation stability of magnetic sensors in IBR-2 (JINR, Dubna) and VVR-M (PNPI, Saint-Petersburg) reactors. The 'Remote-Rad' bench consists of 2 heads (head 1 and head 2) bearing investigated sensors put in a ceramic setting, of electronic unit, of personal computer and of signal lines. Each head contains 6 Hall sensors and a coil for generating test magnetic field. Moreover head 1 contains thermocouples for temperature measurement while the temperature of head 2 is measured by thermo-resistive method. The heads are placed in the reactor channel

  16. Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators

    Science.gov (United States)

    Trolinger, James; Lal, Amit; Jo, Joshua; Kupiec, Stephen

    2012-01-01

    For many aspheric and freeform optical components, existing interferometric solutions require a custom computer-generated hologram (CGH) to characterize the part. The overall objective of this research is to develop hardware and a procedure to produce a combined, dynamic, Hartmann/ Digital Holographic interferometry inspection system for a wide range of advanced optical components, including aspheric and freeform optics. This new instrument would have greater versatility and dynamic range than currently available measurement systems. The method uses a spatial light modulator to pre-condition wavefronts for imaging, interferometry, and data processing to improve the resolution and versatility of an optical inspection instrument. Existing interferometers and Hartmann inspection systems have either too small a dynamic range or insufficient resolution to characterize conveniently unusual optical surfaces like aspherical and freeform optics. For interferometers, a specially produced, computer-generated holographic optical element is needed to transform the wavefront to within the range of the interferometer. A new hybrid wavefront sensor employs newly available spatial light modulators (SLMs) as programmable holographic optical elements (HOEs). The HOE is programmed to enable the same instrument to inspect an optical element in stages, first by a Hartmann measurement, which has a very large dynamic range but less resolution. The first measurement provides the information required to precondition a reference wave that avails the measurement process to the more precise phase shifting interferometry. The SLM preconditions a wavefront before it is used to inspect an optical component. This adds important features to an optical inspection system, enabling not just wavefront conditioning for null testing and dynamic range extension, but also the creation of hybrid measurement procedures. This, for example, allows the combination of dynamic digital holography and Hartmann

  17. MODERN INSTRUMENTAL METHODS TO CONTROL THE SEED QUALITY IN ROOT VEGETABLES

    Directory of Open Access Journals (Sweden)

    F. B. Musaev

    2017-01-01

    Full Text Available The standard methods of analysis don’t meet all modern requirements to determine the seed a quality. These methods can’t unveil inner deficiencies that are very important to control seed viability. The capabilities of new instrumental method to analyze the seed quality of root vegetables were regarded in the article. The method of micro-focus radiography is distinguished from other existing methods by more sensitivity, rapidity and easiness to be performed. Based on practical importance the visualization of inner seed structure, it allows determining far before seed germination the degree of endosperm development and embryo; the presence of inner damages and infections, occupation and damage caused by pests. The use of micro-focus radiography enables to detect the degree of seed quality difference for some traits such as monogermity and self-fertilization that are economically valuable for breeding program in red beet. With the aid of the method the level of seed development, damage and inner deficiencies in carrot and parsnip can be revealed. In X-ray projection seeds of inbred lines of radish significantly differed from variety population ones for their underdevelopment in the inner structure. The advantage of the method is that seeds rest undamaged after quality analyzing and both can be used for further examination with the use of other methods or be sown; that is quite important for breeders, when handling with small quantity or collectable plant breeding material. The results radiography analyses can be saved and archived that enables to watch for seed qualities in dynamic; this data can be also used at possible arbitration cases. 

  18. A fully Bayesian method for jointly fitting instrumental calibration and X-ray spectral models

    International Nuclear Information System (INIS)

    Xu, Jin; Yu, Yaming; Van Dyk, David A.; Kashyap, Vinay L.; Siemiginowska, Aneta; Drake, Jeremy; Ratzlaff, Pete; Connors, Alanna; Meng, Xiao-Li

    2014-01-01

    Owing to a lack of robust principled methods, systematic instrumental uncertainties have generally been ignored in astrophysical data analysis despite wide recognition of the importance of including them. Ignoring calibration uncertainty can cause bias in the estimation of source model parameters and can lead to underestimation of the variance of these estimates. We previously introduced a pragmatic Bayesian method to address this problem. The method is 'pragmatic' in that it introduced an ad hoc technique that simplified computation by neglecting the potential information in the data for narrowing the uncertainty for the calibration product. Following that work, we use a principal component analysis to efficiently represent the uncertainty of the effective area of an X-ray (or γ-ray) telescope. Here, however, we leverage this representation to enable a principled, fully Bayesian method that coherently accounts for the calibration uncertainty in high-energy spectral analysis. In this setting, the method is compared with standard analysis techniques and the pragmatic Bayesian method. The advantage of the fully Bayesian method is that it allows the data to provide information not only for estimation of the source parameters but also for the calibration product—here the effective area, conditional on the adopted spectral model. In this way, it can yield more accurate and efficient estimates of the source parameters along with valid estimates of their uncertainty. Provided that the source spectrum can be accurately described by a parameterized model, this method allows rigorous inference about the effective area by quantifying which possible curves are most consistent with the data.

  19. Calibrating system errors of large scale three-dimensional profile measurement instruments by subaperture stitching method.

    Science.gov (United States)

    Dong, Zhichao; Cheng, Haobo; Feng, Yunpeng; Su, Jingshi; Wu, Hengyu; Tam, Hon-Yuen

    2015-07-01

    This study presents a subaperture stitching method to calibrate system errors of several ∼2  m large scale 3D profile measurement instruments (PMIs). The calibration process was carried out by measuring a Φ460  mm standard flat sample multiple times at different sites of the PMI with a length gauge; then the subaperture data were stitched together using a sequential or simultaneous stitching algorithm that minimizes the inconsistency (i.e., difference) of the discrete data in the overlapped areas. The system error can be used to compensate the measurement results of not only large flats, but also spheres and aspheres. The feasibility of the calibration was validated by measuring a Φ1070  mm aspheric mirror, which can raise the measurement accuracy of PMIs and provide more reliable 3D surface profiles for guiding grinding, lapping, and even initial polishing processes.

  20. Bayesian methods for meta-analysis of causal relationships estimated using genetic instrumental variables

    DEFF Research Database (Denmark)

    Burgess, Stephen; Thompson, Simon G; Thompson, Grahame

    2010-01-01

    Genetic markers can be used as instrumental variables, in an analogous way to randomization in a clinical trial, to estimate the causal relationship between a phenotype and an outcome variable. Our purpose is to extend the existing methods for such Mendelian randomization studies to the context...... of multiple genetic markers measured in multiple studies, based on the analysis of individual participant data. First, for a single genetic marker in one study, we show that the usual ratio of coefficients approach can be reformulated as a regression with heterogeneous error in the explanatory variable....... This can be implemented using a Bayesian approach, which is next extended to include multiple genetic markers. We then propose a hierarchical model for undertaking a meta-analysis of multiple studies, in which it is not necessary that the same genetic markers are measured in each study. This provides...

  1. The behaviour of stacking fault energy upon interstitial alloying.

    Science.gov (United States)

    Lee, Jee-Yong; Koo, Yang Mo; Lu, Song; Vitos, Levente; Kwon, Se Kyun

    2017-09-11

    Stacking fault energy is one of key parameters for understanding the mechanical properties of face-centered cubic materials. It is well known that the plastic deformation mechanism is closely related to the size of stacking fault energy. Although alloying is a conventional method to modify the physical parameter, the underlying microscopic mechanisms are not yet clearly established. Here, we propose a simple model for determining the effect of interstitial alloying on the stacking fault energy. We derive a volumetric behaviour of stacking fault energy from the harmonic approximation to the energy-lattice curve and relate it to the contents of interstitials. The stacking fault energy is found to change linearly with the interstitial content in the usual low concentration domain. This is in good agreement with previously reported experimental and theoretical data.

  2. Eddy Covariance Method for CO2 Emission Measurements: CCS Applications, Principles, Instrumentation and Software

    Science.gov (United States)

    Burba, George; Madsen, Rod; Feese, Kristin

    2013-04-01

    The Eddy Covariance method is a micrometeorological technique for direct high-speed measurements of the transport of gases, heat, and momentum between the earth's surface and the atmosphere. Gas fluxes, emission and exchange rates are carefully characterized from single-point in-situ measurements using permanent or mobile towers, or moving platforms such as automobiles, helicopters, airplanes, etc. Since the early 1990s, this technique has been widely used by micrometeorologists across the globe for quantifying CO2 emission rates from various natural, urban and agricultural ecosystems [1,2], including areas of agricultural carbon sequestration. Presently, over 600 eddy covariance stations are in operation in over 120 countries. In the last 3-5 years, advancements in instrumentation and software have reached the point when they can be effectively used outside the area of micrometeorology, and can prove valuable for geological carbon capture and sequestration, landfill emission measurements, high-precision agriculture and other non-micrometeorological industrial and regulatory applications. In the field of geological carbon capture and sequestration, the magnitude of CO2 seepage fluxes depends on a variety of factors. Emerging projects utilize eddy covariance measurement to monitor large areas where CO2 may escape from the subsurface, to detect and quantify CO2 leakage, and to assure the efficiency of CO2 geological storage [3,4,5,6,7,8]. Although Eddy Covariance is one of the most direct and defensible ways to measure and calculate turbulent fluxes, the method is mathematically complex, and requires careful setup, execution and data processing tailor-fit to a specific site and a project. With this in mind, step-by-step instructions were created to introduce a novice to the conventional Eddy Covariance technique [9], and to assist in further understanding the method through more advanced references such as graduate-level textbooks, flux networks guidelines, journals

  3. Environmental assessment of phosphogypsum stacks

    International Nuclear Information System (INIS)

    Odat, M.; Al-Attar, L.; Raja, G.; Abdul Ghany, B.

    2008-03-01

    Phosphogypsum is one of the most important by-products of phosphate fertilizer industry. It is kept in large stacks to the west of Homs city. Storing Phosphogypsum as open stacks exposed to various environmental effects, wind and rain, may cause pollution of the surrounding ecosystem (soil, plant, water and air). This study was carried out in order to assess the environmental impact of Phosphogypsum stacks on the surrounding ecosystem. The obtained results show that Phosphogypsum stacks did not increase the concentration of radionuclides, i.e. Radon-222 and Radium-226, the external exposed dose of gamma rays, as well as the concentration of heavy metals in the components of the ecosystem, soil, plant, water and air, as their concentrations did not exceed the permissible limits. However, the concentration of fluorine in the upper layer of soil, located to the east of the Phosphogypsum stacks, increased sufficiently, especially in the dry period of the year. Also, the concentration of fluoride in plants growing up near-by the Phosphogypsum stacks was too high, exceeded the permissible levels. This was reflected in poising plants and animals, feeding on the plants. Consequently, increasing the concentration of fluoride in soil and plants is the main impact of Phosphogypsum stacks on the surrounding ecosystem. Minimising this effect could be achieved by establishing a 50 meter wide protection zone surrounding the Phosphogypsum stacks, which has to be planted with non palatable trees, such as pine and cypress, forming wind barriers. Increasing the concentrations of heavy metals and fluoride in infiltrated water around the stacks was high; hence cautions must be taken to prevent its usage in any application or disposal in adjacent rivers and leaks.(author)

  4. Method and apparatus for reducing spacecraft instrument induced jitter via multifrequency cancellation

    Science.gov (United States)

    Liu, Ketao (Inventor); Uetrecht, David S. (Inventor)

    2002-01-01

    A method, apparatus, article of manufacture, and a memory structure for compensating for instrument induced spacecraft jitter is disclosed. The apparatus comprises a spacecraft control processor for producing an actuator command signal, a signal generator, for producing a cancellation signal having at least one harmonic having a frequency and an amplitude substantially equal to that of a disturbance harmonic interacting with a spacecraft structural resonance and a phase substantially out of phase with the disturbance harmonic interacting with the spacecraft structural resonance, and at least one spacecraft control actuator, communicatively coupled to the spacecraft control processor and the signal generator for inducing satellite motion according to the actuator command signal and the cancellation signal. The method comprises the steps of generating a cancellation signal having at least one harmonic having a frequency and an amplitude substantially equal to that of a disturbance harmonic interacting with a spacecraft structural resonance and a phase substantially out of phase with the disturbance harmonic interacting with the spacecraft structural resonance, and providing the cancellation signal to a spacecraft control actuator. The apparatus comprises a storage device tangibly embodying the method steps described above.

  5. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  6. PieceStack: Toward Better Understanding of Stacked Graphs.

    Science.gov (United States)

    Wu, Tongshuang; Wu, Yingcai; Shi, Conglei; Qu, Huamin; Cui, Weiwei

    2016-02-24

    Stacked graphs have been widely adopted in various fields, because they are capable of hierarchically visualizing a set of temporal sequences as well as their aggregation. However, because of visual illusion issues, connections between overly-detailed individual layers and overly-generalized aggregation are intercepted. Consequently, information in this area has yet to be fully excavated. Thus, we present PieceStack in this paper, to reveal the relevance of stacked graphs in understanding intrinsic details of their displayed shapes. This new visual analytic design interprets the ways through which aggregations are generated with individual layers by interactively splitting and re-constructing the stacked graphs. A clustering algorithm is designed to partition stacked graphs into sub-aggregated pieces based on trend similarities of layers. We then visualize the pieces with augmented encoding to help analysts decompose and explore the graphs with respect to their interests. Case studies and a user study are conducted to demonstrate the usefulness of our technique in understanding the formation of stacked graphs.

  7. Electronic structure of the rotation twin stacking fault in β-ZnS

    International Nuclear Information System (INIS)

    Northrup, J.E.; Cohen, M.L.

    1981-01-01

    The electronic structure of the rotation twin stacking fault in β-ZnS is calculated with the self-consistent pseudopotential method. The stacking fault creates a potential barrier of approx.0.07 eV and induces the localization of stacking-fault resonances near the top of the valence band. Stacking-fault states are also predicted to exist in the various gaps in the projected valence-band structure

  8. A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression

    OpenAIRE

    Carolina Brum Medeiros; Marcelo M. Wanderley

    2014-01-01

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The ...

  9. Retrieval methods of effective cloud cover from the GOME instrument: an intercomparison

    Directory of Open Access Journals (Sweden)

    O. N. E. Tuinder

    2004-01-01

    Full Text Available The radiative scattering by clouds leads to errors in the retrieval of column densities and concentration profiles of atmospheric trace gas species from satellites. Moreover, the presence of clouds changes the UV actinic flux and the photo-dissociation rates of various species significantly. The Global Ozone Monitoring Experiment (GOME instrument on the ERS-2 satellite, principally designed to retrieve trace gases in the atmosphere, is also capable of detecting clouds. Four cloud fraction retrieval methods for GOME data that have been developed are discussed in this paper (the Initial Cloud Fitting Algorithm, the PMD Cloud Recognition Algorithm, the Optical Cloud Recognition Algorithm (an in-house version and the official implementation and the Fast Retrieval Scheme for Clouds from the Oxygen A-band. Their results of cloud fraction retrieval are compared to each-other and also to synoptic surface observations. It is shown that all studied retrieval methods calculate an effective cloud fraction that is related to a cloud with a high optical thickness. Generally, we found ICFA to produce the lowest cloud fractions, followed by our in-house OCRA implementation, FRESCO, PC2K and finally the official OCRA implementation along four processed tracks (+2%, +10%, +15% and +25% compared to ICFA respectively. Synoptical surface observations gave the highest absolute cloud fraction when compared with individual PMD sub-pixels of roughly the same size.

  10. Proceedings of a workshop on methods for neutron scattering instrumentation design

    International Nuclear Information System (INIS)

    Hjelm, R.P.

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database

  11. Cluster cosmological analysis with X ray instrumental observables: introduction and testing of AsPIX method

    International Nuclear Information System (INIS)

    Valotti, Andrea

    2016-01-01

    Cosmology is one of the fundamental pillars of astrophysics, as such it contains many unsolved puzzles. To investigate some of those puzzles, we analyze X-ray surveys of galaxy clusters. These surveys are possible thanks to the bremsstrahlung emission of the intra-cluster medium. The simultaneous fit of cluster counts as a function of mass and distance provides an independent measure of cosmological parameters such as Ω_m, σ_s, and the dark energy equation of state w0. A novel approach to cosmological analysis using galaxy cluster data, called top-down, was developed in N. Clerc et al. (2012). This top-down approach is based purely on instrumental observables that are considered in a two-dimensional X-ray color-magnitude diagram. The method self-consistently includes selection effects and scaling relationships. It also provides a means of bypassing the computation of individual cluster masses. My work presents an extension of the top-down method by introducing the apparent size of the cluster, creating a three-dimensional X-ray cluster diagram. The size of a cluster is sensitive to both the cluster mass and its angular diameter, so it must also be included in the assessment of selection effects. The performance of this new method is investigated using a Fisher analysis. In parallel, I have studied the effects of the intrinsic scatter in the cluster size scaling relation on the sample selection as well as on the obtained cosmological parameters. To validate the method, I estimate uncertainties of cosmological parameters with MCMC method Amoeba minimization routine and using two simulated XMM surveys that have an increasing level of complexity. The first simulated survey is a set of toy catalogues of 100 and 10000 deg"2, whereas the second is a 1000 deg"2 catalogue that was generated using an Aardvark semi-analytical N-body simulation. This comparison corroborates the conclusions of the Fisher analysis. In conclusion, I find that a cluster diagram that accounts for

  12. Preliminary study on rotary ultrasonic machining of CFRP/Ti stacks.

    Science.gov (United States)

    Cong, W L; Pei, Z J; Treadwell, C

    2014-08-01

    Reported drilling methods for CFRP/Ti stacks include twist drilling, end milling, core grinding, and their derived methods. The literature does not have any report on drilling of CFRP/Ti stacks using rotary ultrasonic machining (RUM). This paper, for the first time, reports a study on drilling of CFRP/Ti stacks using RUM. It also compares results on drilling of CFRP/Ti stacks using RUM with reported results on drilling of CFRP/Ti stacks using other methods. When drilling CFRP/Ti stacks using RUM, cutting force, torque, and CFRP surface roughness were lower, hole size variation was smaller, CFRP groove depth was smaller, tool life was longer, and there was no obvious Ti exit burr and CFRP entrance delamination. Ti surface roughness when drilling of CFRP/Ti stacks using RUM was about the same as those when using other methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Multi-instrument Method to Map Spatial and Temporal Patterns of Snowmelt Infiltration

    Science.gov (United States)

    Hyde, K.; Beverly, D.; Thayer, D.; Speckman, H. N.; Parsekian, A.; Kelleners, T.

    2015-12-01

    Mapping spatial patterns of relative soil moisture over time may improve understanding of snowmelt infiltration processes in heterogeneous systems. Conventional soil water measurement methods disturb soil properties and rocky materials generally limit installation of monitoring instruments to shallow depths in mountainous landscapes with snowmelt dominated hydrology. Modifications to existing technology combined with low impact installation methods provide high temporal and spatial resolution of relative soil moisture as well as a temperature profile and water table level. Closely spaced (10cm) electrical resistance pads are combined in a small diameter (2.54 cm) tube with temperature probes each 50cm, a pressure transducer, and a tube to extract groundwater for stable isotope analysis. This vertical probe array (VPA) extends 3.2m and is installed in a small diameter (4 cm) bore using a backpack drill limiting soil disturbance. Two VPAs are installed in the Snowy Range of Wyoming, one in a forested mountainous environment impacted by mortality by insects and disease and the other (limited to resistance pads only) in recently burned sagelands. Each VPA is co-located with meteorological stations. Eddy-covariance, sap flux, electrical resistivity, snowpack survey, and other hillslope eco-hydrology measurements accompany the fully instrumented VPA. Data are sampled and recorded at 5 or 15 minute intervals starting in December 2014. Over the winter both sites exhibit highly variable patterns of relatively dry soils with steady increase in wetness. Abrupt increases in relative wetness occurred with short periods of warming temperatures in Spring. Following a temperature increase in the forested site the relative moisture dramatically increased over a period of several hours at all depths as water level rose 1m within 8 hours. In contrast, following snowmelt relative moisture in the sageland site increased gradually and systematically with depth over a period of two weeks

  14. Fast principal component analysis for stacking seismic data

    Science.gov (United States)

    Wu, Juan; Bai, Min

    2018-04-01

    Stacking seismic data plays an indispensable role in many steps of the seismic data processing and imaging workflow. Optimal stacking of seismic data can help mitigate seismic noise and enhance the principal components to a great extent. Traditional average-based seismic stacking methods cannot obtain optimal performance when the ambient noise is extremely strong. We propose a principal component analysis (PCA) algorithm for stacking seismic data without being sensitive to noise level. Considering the computational bottleneck of the classic PCA algorithm in processing massive seismic data, we propose an efficient PCA algorithm to make the proposed method readily applicable for industrial applications. Two numerically designed examples and one real seismic data are used to demonstrate the performance of the presented method.

  15. Stacking by electroinjection with discontinuous buffers in capillary zone electrophoresis.

    Science.gov (United States)

    Shihabi, Zak K

    2002-08-01

    The work presented here demonstrates that electroinjection can be performed using discontinuous buffers, which can result in better stacking than that obtained by hydrodynamic injection. The sample can be concentrated at the tip of the capillary leaving practically the whole capillary for sample separation. This results in several advantages, such as better sample concentration, higher plate number and shorter time of stacking. However, sample introduction by electromigration is suited for samples free or low in salt content. Samples, which are high in salt content, are better introduced by the hydrodynamic injection for stacking by the discontinuous buffers. Different simple methods to introduce the discontinuity in the buffer for electroinjection are discussed.

  16. Assessing learning outcomes in middle-division classical mechanics: The Colorado Classical Mechanics and Math Methods Instrument

    Directory of Open Access Journals (Sweden)

    Marcos D. Caballero

    2017-04-01

    Full Text Available Reliable and validated assessments of introductory physics have been instrumental in driving curricular and pedagogical reforms that lead to improved student learning. As part of an effort to systematically improve our sophomore-level classical mechanics and math methods course (CM 1 at CU Boulder, we have developed a tool to assess student learning of CM 1 concepts in the upper division. The Colorado Classical Mechanics and Math Methods Instrument (CCMI builds on faculty consensus learning goals and systematic observations of student difficulties. The result is a 9-question open-ended post test that probes student learning in the first half of a two-semester classical mechanics and math methods sequence. In this paper, we describe the design and development of this instrument, its validation, and measurements made in classes at CU Boulder and elsewhere.

  17. Assessing learning outcomes in middle-division classical mechanics: The Colorado Classical Mechanics and Math Methods Instrument

    Science.gov (United States)

    Caballero, Marcos D.; Doughty, Leanne; Turnbull, Anna M.; Pepper, Rachel E.; Pollock, Steven J.

    2017-06-01

    Reliable and validated assessments of introductory physics have been instrumental in driving curricular and pedagogical reforms that lead to improved student learning. As part of an effort to systematically improve our sophomore-level classical mechanics and math methods course (CM 1) at CU Boulder, we have developed a tool to assess student learning of CM 1 concepts in the upper division. The Colorado Classical Mechanics and Math Methods Instrument (CCMI) builds on faculty consensus learning goals and systematic observations of student difficulties. The result is a 9-question open-ended post test that probes student learning in the first half of a two-semester classical mechanics and math methods sequence. In this paper, we describe the design and development of this instrument, its validation, and measurements made in classes at CU Boulder and elsewhere.

  18. Non-destructive multielement analysis of airborne particulates by means of instrumental neutron activation method

    International Nuclear Information System (INIS)

    Mamuro, T.

    1981-04-01

    Suspended particles released from various sources, such as iron and steel works, small facilities (metal melting furnaces, heat treatment furnaces), various boilers using different kinds of fuel, and glass manufactures were subjected to multi-element analysis by means of instrumental neutron activation methods and energy dispersive X-ray fluorescence spectrometry. Elemental concentrations of the suspended particles were naturally quite varied. The contribution of various aerosol generating sources to the urban atmosphere was estimated, considering seven main source components, namely soil particles of local and global origin, marine aerosols, suspended particles from iron- and steel industries, refuse incineration, fuel oil combustion and gasoline engine automobiles. Taking seven elements, such as Na, Al, K, Se, V, Un and Pb as index elements, their predicted atmospheric concentrations agreed with the observed ones for major elements within a factor of 1.5. Seasonal variations of atmospheric concentrations of various elements over some areas in Japan were observed. It was found that the concentration of global aerosol originating from the continental soil becomes high in spring, resulting in high concentrations of lithoidal elements, such as Al and Sc. Contrary to this, the concentration of elements originating mainly from human activities becomes high around November and December

  19. Trace elements determination in silicon and ferrosilicon reference materials by instrumental neutron activation analysis method

    International Nuclear Information System (INIS)

    Moreira, Edson Goncalves; Vasconcellos, Marina Beatriz Agostini; Saiki, Mitiko; Iamashita, Celia Omine

    2002-01-01

    The use of certified reference materials, CRM, is of uppermost importance in the rastreability realization of the measurement process. At times, CRM use is restricted by the non existence of a suitable CRM with similarity to the sample in respect to matrix composition or with element levels in different orders of magnitude. IPT Chemical Division launched a project to prepare a metallic silicon CRM, due to the requirements of the industries in this field. To characterize this new CRM, IPEN Nuclear Reactor Center is able to perform instrumental neutron activation analysis, INAA, a very suitable method for silicon matrix samples because they produce basically the short lived radionuclide 3 1 Si under thermal neutrons flux, which after radioactive decay, does not interfere in the determination of other elements. In this paper, it is presented the determination of As, Br, Co, Cr, K, Eu, Fe, La, Mn, Na Nb, Sb, Sm, Sc, Th, Tb, U, V, W and Yb in silicon CRM NBS SRM 57; ferrosilicon CRM IPT 56; IPT 70; NBS SRM 58a; NBS SRM 59a and silicon RM under preparation IPT 132. From the results, the accuracy and the precision of the process were assessed. (author)

  20. Waste minimization methods for treating analytical instrumentation effluents at the source

    International Nuclear Information System (INIS)

    Ritter, J.A.; Barnhart, C.

    1995-01-01

    The primary goal of this project was to reduce the amount of hazardous waste being generated by the Savannah River Siste Defense Waste Processing Technology-analytical Laboratory (DWPT-AL). A detailed characterization study was performed on 12 of the liquid effluent streams generated within the DWPT-AL. Two of the streams were not hazardous, and are now being collected separately from the 10 hazardous streams. A secondary goal of the project was to develop in-line methods using primarily adsorption/ion exchange columns to treat liquid effluent as it emerges from the analytical instrument as a slow, dripping flow. Samples from the 10 hazardous streams were treated by adsorption in an experimental apparatus that resembled an in-line or at source column apparatus. The layered adsorbent bed contained activated carbon and ion exchange resin. The column technique did not work on the first three samples of the spectroscopy waste stream, but worked well on the next three samples which were treated in a different column. It was determined that an unusual form of mercury was present in the first three samples. Similarly, two samples of a combined waste stream were rendered nonhazardous, but the last two samples contained acetylnitrile that prevented analysis. The characteristics of these streams changed from the initial characterization study; therefore, continual, in-deptch stream characterization is the key to making this project successful

  1. Creation of an Australian Osteotomy Knee Registry Datasheet Instrument using a Modified Delphi Method

    Science.gov (United States)

    Vertullo, Christopher J.

    2017-01-01

    Background: In 2015, the Australian Knee Society(AKS) agreed to initiate and fund an Australian Knee Osteotomy Registry (AKOR) in 2015 in conjunction with the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). A concise and robust dataset was required to proceed to AKOR preliminary site trialing. Study Design: Modified Delphi consensus building. Methods: Seven participants who were orthopaedic surgeons, AKS members and AKOR working group members performed a four round modified Delphi consensus building electronic non-blinded questionnaires using Google Sheets, a cloud-based spreadsheet. Round 1 involved the attribute rating using 0-10 of surgeon assessed utility of 41 initial datasheet instrument questions with 168 stem options. Surgeons could comment on each question or stem, giving comments on their rating and or proposing new variations or additions. Round 1 questions were based on the Swedish HTO Registry dataset with additional questions from surgeon interview. Questions and or stems with a mean utility rating of less than 2 were excluded. Questions and or stems with a mean utility raking of 8 or greater were accepted. Questions and or stem with a mean utility ranking of between 8 and 2 were included in subsequent rounds. Surgeons comments and votes were non-blinded. New or alternative questions or stems could be proposed by any surgeon during the process and voted on in the next round. This process was repeated until dataset consensus was achieved. Results: A final dataset of 32 questions was created after 4 rounds. Consensus was reached on the following items; patients demographics, hospital, state, surgeon’s code, date, primary or re-operation, diagnosis at primary procedure, diagnosis at re-operation, type of primary osteotomy, type of re-operation, form of fixation, bone graft, coincidental surgery, approach to correction calculation, pre-operative status of ACL, pre-operative status of PCL, previous knee surgery

  2. Learning algorithms for stack filter classifiers

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Reid B [Los Alamos National Laboratory; Hush, Don [Los Alamos National Laboratory; Zimmer, Beate G [TEXAS A& M

    2009-01-01

    Stack Filters define a large class of increasing filter that is used widely in image and signal processing. The motivations for using an increasing filter instead of an unconstrained filter have been described as: (1) fast and efficient implementation, (2) the relationship to mathematical morphology and (3) more precise estimation with finite sample data. This last motivation is related to methods developed in machine learning and the relationship was explored in an earlier paper. In this paper we investigate this relationship by applying Stack Filters directly to classification problems. This provides a new perspective on how monotonicity constraints can help control estimation and approximation errors, and also suggests several new learning algorithms for Boolean function classifiers when they are applied to real-valued inputs.

  3. Industrial stacks design; Diseno de chimeneas industriales

    Energy Technology Data Exchange (ETDEWEB)

    Cacheux, Luis [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1986-12-31

    The Instituto de Investigaciones Electricas (IIE) though its Civil Works Department, develops, under contract with CFE`s Gerencia de Proyectos Termoelectricos (Management of Fossil Power Plant Projects), a series of methods for the design of stacks, which pretends to solve the a present day problem: the stack design of the fossil power plants that will go into operation during the next coming years in the country. [Espanol] El Instituto de Investigaciones Electricas (IIE), a traves del Departamento de Ingenieria Civil, desarrolla, bajo contrato con la Gerencia de Proyectos Termoelectricos, de la Comision Federal de Electricidad (CFE), un conjunto de metodos para el diseno de chimeneas, con el que se pretende resolver un problema inmediato: el diseno de las chimeneas de las centrales termoelectricas que entraran en operacion durante los proximos anos, en el pais.

  4. Multistage Force Amplification of Piezoelectric Stacks

    Science.gov (United States)

    Xu, Tian-Bing (Inventor); Siochi, Emilie J. (Inventor); Zuo, Lei (Inventor); Jiang, Xiaoning (Inventor); Kang, Jin Ho (Inventor)

    2015-01-01

    Embodiments of the disclosure include an apparatus and methods for using a piezoelectric device, that includes an outer flextensional casing, a first cell and a last cell serially coupled to each other and coupled to the outer flextensional casing such that each cell having a flextensional cell structure and each cell receives an input force and provides an output force that is amplified based on the input force. The apparatus further includes a piezoelectric stack coupled to each cell such that the piezoelectric stack of each cell provides piezoelectric energy based on the output force for each cell. Further, the last cell receives an input force that is the output force from the first cell and the last cell provides an output apparatus force In addition, the piezoelectric energy harvested is based on the output apparatus force. Moreover, the apparatus provides displacement based on the output apparatus force.

  5. Extrapolation method of the elimination of instrumental broadening of diffraction lines

    Czech Academy of Sciences Publication Activity Database

    Čerňanský, Marian

    2000-01-01

    Roč. 7, č. 1 (2000), s. 3-5 ISSN 1211-5894 Institutional research plan: CEZ:AV0Z1010914 Keywords : XRD line brodening * instrumental broadening * powder diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism

  6. AC impedance diagnosis of a 500 W PEM fuel cell stack . Part I: Stack impedance

    Science.gov (United States)

    Yuan, Xiaozi; Sun, Jian Colin; Blanco, Mauricio; Wang, Haijiang; Zhang, Jiujun; Wilkinson, David P.

    Diagnosis of stack performance is of importance to proton exchange membrane (PEM) fuel cell research. This paper presents the diagnostic testing results of a 500 W Ballard Mark V PEM fuel cell stack with an active area of 280 cm 2 by electrochemical impedance spectroscopy (EIS). The EIS was measured using a combination of a FuelCon test station, a TDI loadbank, and a Solartron 1260 Impedance/Gain-Phase Analyzer operating in the galvanostatic mode. The method described in this work can obtain the impedance spectra of fuel cells with a larger geometric surface area and power, which are normally difficult to measure due to the limitations on commercial load banks operating at high currents. By using this method, the effects of temperature, flow rate, and humidity on the stack impedance spectra were examined. The results of the electrochemical impedance analysis show that with increasing temperature, the charge transfer resistance decreases due to the slow oxygen reduction reaction (ORR) process at low temperature. If the stack is operated at a fixed air flow rate, a low frequency arc appears and grows with increasing current due to the shortage of air. The anode humidification cut-off does not affect the spectra compared to the cut-off for cathode humidification.

  7. A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression

    Science.gov (United States)

    Medeiros, Carolina Brum; Wanderley, Marcelo M.

    2014-01-01

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments. PMID:25068865

  8. A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression

    Directory of Open Access Journals (Sweden)

    Carolina Brum Medeiros

    2014-07-01

    Full Text Available Digital Musical Instruments (DMIs are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013. Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.

  9. A comprehensive review of sensors and instrumentation methods in devices for musical expression.

    Science.gov (United States)

    Medeiros, Carolina Brum; Wanderley, Marcelo M

    2014-07-25

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009-2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.

  10. Application of the Langley plot method to the calibration of the solar backscattered ultraviolet instrument on the Nimbus 7 satellite

    Science.gov (United States)

    Bhartia, P. K.; Taylor, S.; Mcpeters, R. D.; Wellemeyer, C.

    1995-01-01

    The concept of the well-known Langley plot technique, used for the calibration of ground-based instruments, has been generalized for application to satellite instruments. In polar regions, near summer solstice, the solar backscattered ultraviolet (SBUV) instrument on the Nimbus 7 satellite samples the same ozone field at widely different solar zenith angles. These measurements are compared to assess the long-term drift in the instrument calibration. Although the technique provides only a relative wavelength-to-wavelength calibration, it can be combined with existing techniques to determine the drift of the instrument at any wavelength. Using this technique, we have generated a 12-year data set of ozone vertical profiles from SBUV with an estimated accuracy of +/- 5% at 1 mbar and +/- 2% at 10 mbar (95% confidence) over 12 years. Since the method is insensitive to true changes in the atmospheric ozone profile, it can also be used to compare the calibrations of similar SBUV instruments launched without temporal overlap.

  11. Dose assessment for potential radionuclide emissions from stacks on the Hanford Site: NESHAP compliance

    International Nuclear Information System (INIS)

    Davis, W.E.; Barnett, J.M.; Kenoyer, J.L.

    1994-03-01

    The purpose of this document is to present the assessment results for the registered stacks on the Hanford Site for potential emissions, i.e. emissions with no control devices in place. Further, the document will identify those stacks requiring continuous monitoring, i.e. the effective dose equivalent from potential emissions >0.1 mrem/yr. The stack assessment of potential emissions was performed on 84 registered stacks on the Hanford Site. These emission sources represent individual point sources presently registered under Washington Administrative code 246-247 with the Washington Department of Health. The methods used in assessing the potential emissions from the stacks are described

  12. The Signal Validation method of Digital Process Instrumentation System on signal conditioner for SMART

    International Nuclear Information System (INIS)

    Moon, Hee Gun; Park, Sang Min; Kim, Jung Seon; Shon, Chang Ho; Park, Heui Youn; Koo, In Soo

    2005-01-01

    The function of PIS(Process Instrumentation System) for SMART is to acquire the process data from sensor or transmitter. The PIS consists of signal conditioner, A/D converter, DSP(Digital Signal Process) and NIC(Network Interface Card). So, It is fully digital system after A/D converter. The PI cabinet and PDAS(Plant Data Acquisition System) in commercial plant is responsible for data acquisition of the sensor or transmitter include RTD, TC, level, flow, pressure and so on. The PDAS has the software that processes each sensor data and PI cabinet has the signal conditioner, which is need for maintenance and test. The signal conditioner has the potentiometer to adjust the span and zero for test and maintenance. The PIS of SMART also has the signal conditioner which has the span and zero adjust same as the commercial plant because the signal conditioner perform the signal condition for AD converter such as 0∼10Vdc. But, To adjust span and zero is manual test and calibration. So, This paper presents the method of signal validation and calibration, which is used by digital feature in SMART. There are I/E(current to voltage), R/E(resistor to voltage), F/E(frequency to voltage), V/V(voltage to voltage). Etc. In this paper show only the signal validation and calibration about I/E converter that convert level, pressure, flow such as 4∼20mA into signal for AD conversion such as 0∼10Vdc

  13. Data Quality Control: Challenges, Methods, and Solutions from an Eco-Hydrologic Instrumentation Network

    Science.gov (United States)

    Eiriksson, D.; Jones, A. S.; Horsburgh, J. S.; Cox, C.; Dastrup, D.

    2017-12-01

    Over the past few decades, advances in electronic dataloggers and in situ sensor technology have revolutionized our ability to monitor air, soil, and water to address questions in the environmental sciences. The increased spatial and temporal resolution of in situ data is alluring. However, an often overlooked aspect of these advances are the challenges data managers and technicians face in performing quality control on millions of data points collected every year. While there is general agreement that high quantities of data offer little value unless the data are of high quality, it is commonly understood that despite efforts toward quality assurance, environmental data collection occasionally goes wrong. After identifying erroneous data, data managers and technicians must determine whether to flag, delete, leave unaltered, or retroactively correct suspect data. While individual instrumentation networks often develop their own QA/QC procedures, there is a scarcity of consensus and literature regarding specific solutions and methods for correcting data. This may be because back correction efforts are time consuming, so suspect data are often simply abandoned. Correction techniques are also rarely reported in the literature, likely because corrections are often performed by technicians rather than the researchers who write the scientific papers. Details of correction procedures are often glossed over as a minor component of data collection and processing. To help address this disconnect, we present case studies of quality control challenges, solutions, and lessons learned from a large scale, multi-watershed environmental observatory in Northern Utah that monitors Gradients Along Mountain to Urban Transitions (GAMUT). The GAMUT network consists of over 40 individual climate, water quality, and storm drain monitoring stations that have collected more than 200 million unique data points in four years of operation. In all of our examples, we emphasize that scientists

  14. Time-predictable Stack Caching

    DEFF Research Database (Denmark)

    Abbaspourseyedi, Sahar

    completely. Thus, in systems with hard deadlines the worst-case execution time (WCET) of the real-time software running on them needs to be bounded. Modern architectures use features such as pipelining and caches for improving the average performance. These features, however, make the WCET analysis more...... addresses, provides an opportunity to predict and tighten the WCET of accesses to data in caches. In this thesis, we introduce the time-predictable stack cache design and implementation within a time-predictable processor. We introduce several optimizations to our design for tightening the WCET while...... keeping the timepredictability of the design intact. Moreover, we provide a solution for reducing the cost of context switching in a system using the stack cache. In design of these caches, we use custom hardware and compiler support for delivering time-predictable stack data accesses. Furthermore...

  15. Glassy carbon based supercapacitor stacks

    Energy Technology Data Exchange (ETDEWEB)

    Baertsch, M.; Braun, A.; Koetz, R.; Haas, O. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    Considerable effort is being made to develop electrochemical double layer capacitors (EDLC) that store relatively large quantities of electrical energy and possess at the same time a high power density. Our previous work has shown that glassy carbon is suitable as a material for capacitor electrodes concerning low resistance and high capacity requirements. We present the development of bipolar electrochemical glassy carbon capacitor stacks of up to 3 V. Bipolar stacks are an efficient way to meet the high voltage and high power density requirements for traction applications. Impedance and cyclic voltammogram measurements are reported here and show the frequency response of a 1, 2, and 3 V stack. (author) 3 figs., 1 ref..

  16. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    Science.gov (United States)

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  17. Electrochemical Detection in Stacked Paper Networks.

    Science.gov (United States)

    Liu, Xiyuan; Lillehoj, Peter B

    2015-08-01

    Paper-based electrochemical biosensors are a promising technology that enables rapid, quantitative measurements on an inexpensive platform. However, the control of liquids in paper networks is generally limited to a single sample delivery step. Here, we propose a simple method to automate the loading and delivery of liquid samples to sensing electrodes on paper networks by stacking multiple layers of paper. Using these stacked paper devices (SPDs), we demonstrate a unique strategy to fully immerse planar electrodes by aqueous liquids via capillary flow. Amperometric measurements of xanthine oxidase revealed that electrochemical sensors on four-layer SPDs generated detection signals up to 75% higher compared with those on single-layer paper devices. Furthermore, measurements could be performed with minimal user involvement and completed within 30 min. Due to its simplicity, enhanced automation, and capability for quantitative measurements, stacked paper electrochemical biosensors can be useful tools for point-of-care testing in resource-limited settings. © 2015 Society for Laboratory Automation and Screening.

  18. Geography Teachers' Views on the Assessment and Evaluation Instruments and Methods Used in the Renewed Geography Curriculum

    Science.gov (United States)

    Pinar, Adnan

    2011-01-01

    The aim of this study is to reveal the teachers' views regarding the recommended instruments and methods of measuring assessment in Geography Course Curriculum that has been in practice in Turkey since 2005. In the qualitatively planned research, the data has been analysed from the discussions of 10 different geography teachers, 4 of them females,…

  19. Assessing Learning Outcomes in Middle-Division Classical Mechanics: The Colorado Classical Mechanics and Math Methods Instrument

    Science.gov (United States)

    Caballero, Marcos D.; Doughty, Leanne; Turnbull, Anna M.; Pepper, Rachel E.; Pollock, Steven J.

    2017-01-01

    Reliable and validated assessments of introductory physics have been instrumental in driving curricular and pedagogical reforms that lead to improved student learning. As part of an effort to systematically improve our sophomore-level classical mechanics and math methods course (CM 1) at CU Boulder, we have developed a tool to assess student…

  20. Qualitative to Quantitative and Spectrum to Report: An Instrument-Focused Research Methods Course for First-Year Students

    Science.gov (United States)

    Thomas, Alyssa C.; Boucher, Michelle A.; Pulliam, Curtis R.

    2015-01-01

    Our Introduction to Research Methods course is a first-year majors course built around the idea of helping students learn to work like chemists, write like chemists, and think like chemists. We have developed this course as a hybrid hands-on/ lecture experience built around instrumentation use and report preparation. We take the product from one…

  1. Simulating Small-Scale Object Stacking Using Stack Stability

    DEFF Research Database (Denmark)

    Kronborg Thomsen, Kasper; Kraus, Martin

    2015-01-01

    This paper presents an extension system to a closed-source, real-time physics engine for improving structured stacking behavior with small-scale objects such as wooden toy bricks. The proposed system was implemented and evaluated. The tests showed that the system is able to simulate several common...

  2. Improved methods for signal processing in measurements of mercury by Tekran® 2537A and 2537B instruments

    Science.gov (United States)

    Ambrose, Jesse L.

    2017-12-01

    Atmospheric Hg measurements are commonly carried out using Tekran® Instruments Corporation's model 2537 Hg vapor analyzers, which employ gold amalgamation preconcentration sampling and detection by thermal desorption (TD) and atomic fluorescence spectrometry (AFS). A generally overlooked and poorly characterized source of analytical uncertainty in those measurements is the method by which the raw Hg atomic fluorescence (AF) signal is processed. Here I describe new software-based methods for processing the raw signal from the Tekran® 2537 instruments, and I evaluate the performances of those methods together with the standard Tekran® internal signal processing method. For test datasets from two Tekran® instruments (one 2537A and one 2537B), I estimate that signal processing uncertainties in Hg loadings determined with the Tekran® method are within ±[1 % + 1.2 pg] and ±[6 % + 0.21 pg], respectively. I demonstrate that the Tekran® method can produce significant low biases (≥ 5 %) not only at low Hg sample loadings (mercury (GEM) and total mercury (THg) (˜ 1 to 2 ng m-3) under typical operating conditions (sample loadings of 5-10 pg). Signal processing uncertainties associated with the Tekran® method can therefore represent a significant unaccounted for addition to the overall ˜ 10 to 15 % uncertainty previously estimated for Tekran®-based GEM and THg measurements. Signal processing bias can also add significantly to uncertainties in Tekran®-based gaseous oxidized mercury (GOM) and particle-bound mercury (PBM) measurements, which often derive from Hg sample loadings Mercury limits of detection (LODs) decrease by 31 to 88 % when the new methods are used in place of the Tekran® method. I recommend that signal processing uncertainties be quantified in future applications of the Tekran® 2537 instruments.

  3. High-precision measurement of an involute artefact by a rolling method and comparison between measuring instruments

    International Nuclear Information System (INIS)

    Takeoka, Fumi; Komori, Masaharu; Kubo, Aizoh; Fujio, Hiroshige; Ito, Takehiro; Takatsuji, Toshiyuki; Osawa, Sonko; Sato, Osamu; Takeda, Ryohei

    2009-01-01

    The vibration of gears is a serious problem for machines. The characteristics of the vibration of gears are affected by tooth flank form deviation of submicrometre order. The quality of product gears is controlled by a gear-measuring instrument, which is calibrated by an involute artefact with high precision. A highly precise method for measuring the involute artefact by rolling has been proposed. However, this method does not yield sufficient accuracy. In this research, a novel rolling method for the involute artefact, a 'nonslip driving method', is proposed to achieve high accuracy. This method is compared with the conventional driving method by theoretical analysis of artefact motion. Moreover, its accuracy and effect are evaluated experimentally. The results show that this method is more stable on the basis of measurement results than the conventional driving method. Therefore, it is confirmed that the highly precise measurement of the involute artefact can be realized by incorporating the nonslip driving method into the rolling artefact method. In addition, measurement results for the involute artefact are compared among the proposed method and the methods involving the use of a coordinate measuring machine and a gear-measuring instrument

  4. The Direct FuelCell™ stack engineering

    Science.gov (United States)

    Doyon, J.; Farooque, M.; Maru, H.

    FuelCell Energy (FCE) has developed power plants in the size range of 300 kW to 3 MW for distributed power generation. Field-testing of the sub-megawatt plants is underway. The FCE power plants are based on its Direct FuelCell™ (DFC) technology. This is so named because of its ability to generate electricity directly from a hydrocarbon fuel, such as natural gas, by reforming it inside the fuel cell stack itself. All FCE products use identical 8000 cm 2 cell design, approximately 350-400 cells per stack, external gas manifolds, and similar stack compression systems. The difference lies in the packaging of the stacks inside the stack module. The sub-megawatt system stack module contains a single horizontal stack whereas the MW-class stack module houses four identical vertical stacks. The commonality of the design, internal reforming features, and atmospheric operation simplify the system design, reduce cost, improve efficiency, increase reliability and maintainability. The product building-block stack design has been advanced through three full-size stack operations at company's headquarters in Danbury, CT. The initial proof-of-concept of the full-size stack design was verified in 1999, followed by a 1.5 year of endurance verification in 2000-2001, and currently a value-engineered stack version is in operation. This paper discusses the design features, important engineering solutions implemented, and test results of FCE's full-size DFC stacks.

  5. On-site detection of stacked genetically modified soybean based on event-specific TM-LAMP and a DNAzyme-lateral flow biosensor.

    Science.gov (United States)

    Cheng, Nan; Shang, Ying; Xu, Yuancong; Zhang, Li; Luo, Yunbo; Huang, Kunlun; Xu, Wentao

    2017-05-15

    Stacked genetically modified organisms (GMO) are becoming popular for their enhanced production efficiency and improved functional properties, and on-site detection of stacked GMO is an urgent challenge to be solved. In this study, we developed a cascade system combining event-specific tag-labeled multiplex LAMP with a DNAzyme-lateral flow biosensor for reliable detection of stacked events (DP305423× GTS 40-3-2). Three primer sets, both event-specific and soybean species-specific, were newly designed for the tag-labeled multiplex LAMP system. A trident-like lateral flow biosensor displayed amplified products simultaneously without cross contamination, and DNAzyme enhancement improved the sensitivity effectively. After optimization, the limit of detection was approximately 0.1% (w/w) for stacked GM soybean, which is sensitive enough to detect genetically modified content up to a threshold value established by several countries for regulatory compliance. The entire detection process could be shortened to 120min without any large-scale instrumentation. This method may be useful for the in-field detection of DP305423× GTS 40-3-2 soybean on a single kernel basis and on-site screening tests of stacked GM soybean lines and individual parent GM soybean lines in highly processed foods. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. New instruments and methods for measuring the concentration of radioactive products in the atmosphere

    International Nuclear Information System (INIS)

    Jehanno, C.; Blanc, A.; Lallemant, C.; Roux, G.

    1959-01-01

    Different recorders for radioactive aerosols have been developed for measuring the pollution of the atmosphere in laboratories or the external atmosphere. EAR 600. - Allows continuous measurement, instantaneously and 3 to 10 hours after sampling, of concentrations of α or β emitting aerosols varying between some 10 -11 and some 10 -8 curie per cubic metre of air. EAR 800. - Allows continuous measurement of concentration of α emitting aerosols varying between 10 -11 and 10 -5 curie per cubic metre of air and concentration of β emitting aerosols from 10 -11 to 10 -1 curie per cubic metre of air. EAR Plutonium. - Allows detection after several minutes of 1000 MPD (2 x 10 -9 curie par cubic metre), and after 8 hours 1 MPD (2 x 10 -12 curie per cubic metre). Two methods are used to separate the activity due to plutonium from that due to the descendants of radon and thoron: a) by amplitude discrimination, b) by RaC-RaC' and ThC-ThC' (α β ) coincidences. SP4. This system, mounted on a jeep, allows the measurement of irradiation produced on the ground by the smoke from the piles. The sensitivity is 5μR/h. A.D.I.R. - This autonomous and portable instrument is designed for the instantaneous measurement of the radon content of the atmosphere in mines. It allows the measurement of contents in air varying between 0.4 and 400 x 10 -10 curie per litre of air (0.4 and 400 MPD). The measurement of radioactive fall-out is carried out after collection of this activity by a special rain gauge which comprises an adhesive surface and a tube containing ion exchange resins. The radioactivity of the fall-out varies between some 10 -9 and some 10 -7 curie per square metre per month. Concentrations in fission products of the atmosphere are measured after collecting on filter paper. Concentrations measured in air at ground level vary between 10 -13 and 10 -12 curie per cubic metre. (author) [fr

  7. Advanced Instrumentation and Control Methods for Small and Medium Reactors with IRIS Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    J. Wesley Hines; Belle R. Upadhyaya; J. Michael Doster; Robert M. Edwards; Kenneth D. Lewis; Paul Turinsky; Jamie Coble

    2011-05-31

    Development and deployment of small-scale nuclear power reactors and their maintenance, monitoring, and control are part of the mission under the Small Modular Reactor (SMR) program. The objectives of this NERI-consortium research project are to investigate, develop, and validate advanced methods for sensing, controlling, monitoring, diagnosis, and prognosis of these reactors, and to demonstrate the methods with application to one of the proposed integral pressurized water reactors (IPWR). For this project, the IPWR design by Westinghouse, the International Reactor Secure and Innovative (IRIS), has been used to demonstrate the techniques developed under this project. The research focuses on three topical areas with the following objectives. Objective 1 - Develop and apply simulation capabilities and sensitivity/uncertainty analysis methods to address sensor deployment analysis and small grid stability issues. Objective 2 - Develop and test an autonomous and fault-tolerant control architecture and apply to the IRIS system and an experimental flow control loop, with extensions to multiple reactor modules, nuclear desalination, and optimal sensor placement strategy. Objective 3 - Develop and test an integrated monitoring, diagnosis, and prognosis system for SMRs using the IRIS as a test platform, and integrate process and equipment monitoring (PEM) and process and equipment prognostics (PEP) toolboxes. The research tasks are focused on meeting the unique needs of reactors that may be deployed to remote locations or to developing countries with limited support infrastructure. These applications will require smaller, robust reactor designs with advanced technologies for sensors, instrumentation, and control. An excellent overview of SMRs is described in an article by Ingersoll (2009). The article refers to these as deliberately small reactors. Most of these have modular characteristics, with multiple units deployed at the same plant site. Additionally, the topics focus

  8. Stack semantics of type theory

    DEFF Research Database (Denmark)

    Coquand, Thierry; Mannaa, Bassel; Ruch, Fabian

    2017-01-01

    We give a model of dependent type theory with one univalent universe and propositional truncation interpreting a type as a stack, generalizing the groupoid model of type theory. As an application, we show that countable choice cannot be proved in dependent type theory with one univalent universe...

  9. Multilayer Piezoelectric Stack Actuator Characterization

    Science.gov (United States)

    Sherrit, Stewart; Jones, Christopher M.; Aldrich, Jack B.; Blodget, Chad; Bao, Xioaqi; Badescu, Mircea; Bar-Cohen, Yoseph

    2008-01-01

    Future NASA missions are increasingly seeking to use actuators for precision positioning to accuracies of the order of fractions of a nanometer. For this purpose, multilayer piezoelectric stacks are being considered as actuators for driving these precision mechanisms. In this study, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and extreme temperatures and voltages. AC signal testing included impedance, capacitance and dielectric loss factor of each actuator as a function of the small-signal driving sinusoidal frequency, and the ambient temperature. DC signal testing includes leakage current and displacement as a function of the applied DC voltage. The applied DC voltage was increased to over eight times the manufacturers' specifications to investigate the correlation between leakage current and breakdown voltage. Resonance characterization as a function of temperature was done over a temperature range of -180C to +200C which generally exceeded the manufacturers' specifications. In order to study the lifetime performance of these stacks, five actuators from one manufacturer were driven by a 60volt, 2 kHz sine-wave for ten billion cycles. The tests were performed using a Lab-View controlled automated data acquisition system that monitored the waveform of the stack electrical current and voltage. The measurements included the displacement, impedance, capacitance and leakage current and the analysis of the experimental results will be presented.

  10. Open stack thermal battery tests

    Energy Technology Data Exchange (ETDEWEB)

    Long, Kevin N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Roberts, Christine C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grillet, Anne M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Headley, Alexander J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fenton, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wong, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingersoll, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-04-17

    We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transverse to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.

  11. Adding large EM stack support

    KAUST Repository

    Holst, Glendon

    2016-12-01

    Serial section electron microscopy (SSEM) image stacks generated using high throughput microscopy techniques are an integral tool for investigating brain connectivity and cell morphology. FIB or 3View scanning electron microscopes easily generate gigabytes of data. In order to produce analyzable 3D dataset from the imaged volumes, efficient and reliable image segmentation is crucial. Classical manual approaches to segmentation are time consuming and labour intensive. Semiautomatic seeded watershed segmentation algorithms, such as those implemented by ilastik image processing software, are a very powerful alternative, substantially speeding up segmentation times. We have used ilastik effectively for small EM stacks – on a laptop, no less; however, ilastik was unable to carve the large EM stacks we needed to segment because its memory requirements grew too large – even for the biggest workstations we had available. For this reason, we refactored the carving module of ilastik to scale it up to large EM stacks on large workstations, and tested its efficiency. We modified the carving module, building on existing blockwise processing functionality to process data in manageable chunks that can fit within RAM (main memory). We review this refactoring work, highlighting the software architecture, design choices, modifications, and issues encountered.

  12. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation.

    Science.gov (United States)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker; Fredenslund, Anders M; Scheutz, Charlotte

    2018-04-04

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument and tracer gas combinations. Analytical instruments with a high detection frequency and good precision were established as the most suitable for successful TDM application. The application of an instrument with a poor precision could only to some extent be overcome by applying a higher tracer gas release rate. A sideward misplacement of the tracer gas release point of about 250m resulted in an emission rate comparable to those obtained using a tracer gas correctly simulating the methane emission. Conversely, an upwind misplacement of about 150m resulted in an emission rate overestimation of almost 50%, showing the importance of proper emission source simulation when applying the TDM. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Factor analysis methods and validity evidence: A systematic review of instrument development across the continuum of medical education

    Science.gov (United States)

    Wetzel, Angela Payne

    Previous systematic reviews indicate a lack of reporting of reliability and validity evidence in subsets of the medical education literature. Psychology and general education reviews of factor analysis also indicate gaps between current and best practices; yet, a comprehensive review of exploratory factor analysis in instrument development across the continuum of medical education had not been previously identified. Therefore, the purpose for this study was critical review of instrument development articles employing exploratory factor or principal component analysis published in medical education (2006--2010) to describe and assess the reporting of methods and validity evidence based on the Standards for Educational and Psychological Testing and factor analysis best practices. Data extraction of 64 articles measuring a variety of constructs that have been published throughout the peer-reviewed medical education literature indicate significant errors in the translation of exploratory factor analysis best practices to current practice. Further, techniques for establishing validity evidence tend to derive from a limited scope of methods including reliability statistics to support internal structure and support for test content. Instruments reviewed for this study lacked supporting evidence based on relationships with other variables and response process, and evidence based on consequences of testing was not evident. Findings suggest a need for further professional development within the medical education researcher community related to (1) appropriate factor analysis methodology and reporting and (2) the importance of pursuing multiple sources of reliability and validity evidence to construct a well-supported argument for the inferences made from the instrument. Medical education researchers and educators should be cautious in adopting instruments from the literature and carefully review available evidence. Finally, editors and reviewers are encouraged to recognize

  14. Report on the Verification of the Performance of MON 87708 and MON 89788 Event-specific PCR-based Methods Applied to DNA Extracted from GM Stack MON 87708 x MON 89788 Soybean

    OpenAIRE

    JACCHIA SARA; SACCO Maria-Grazia; MAZZARA Marco; KREYSA JOACHIM

    2014-01-01

    An application was submitted by Monsanto Company to request the authorisation of genetically modified stack (GM stack) MON 87708 × MON 89788 soybean (tolerant to dicamba and to glyphosate) and all sub-combinations of the individual events as present in the segregating progeny, for food and feed uses, and import and processing, in accordance with articles 5 and 17 of Regulation (EC) N° 1829/2003 GM Food and GM Feed. The unique identifier assigned to GM stack MON 87708 × MON 89788 soybean is MO...

  15. Modern Instrumental Methods to Investigate the Mechanism of Biological Decay in Wood Plastic Composites

    Science.gov (United States)

    Grace Sun; Rebecca Ibach; Marek Gnatowski; Jessie Glaeser; Mathew Leung; John. Haight

    2014-01-01

    Various instrumental techniques were used to study the fungal decay process in wood plastic composite (WPC) boards. Commercial boards exposed near Hilo, Hawaii (HI) for eight years in both sun and shadow locations were inspected and tested periodically. After eight years of exposure, both boards were evaluated using magnetic resonance imaging (MRI), while a selected...

  16. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Development of instrumentation, data aquisition software and processing methods

    NARCIS (Netherlands)

    Barbu, I.M.

    2008-01-01

    This thesis describes, the use of a Fourier Transform Ion Cyclotron (FTICR) mass spectrometer in the study of biological samples with, imaging mass spectrometry (MS). To achieve this goal experiments were performed on an in-house modified FTICR-MS instrument (for which special acquisition software

  17. On the relationship between the irregular reflector and the data processing by stacking; Hanshamen keijo to jugo shori ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, J.; Yokota, T.; Miyazaki, T. [Geological Survey of Japan, Tsukuba (Japan); Rokukawa, S. [The University of Tokyo, Tokyo (Japan). Faculty of Engineering

    1996-05-01

    An examination was made on the possibility of data processing by stacking with scattered waves assumed in a seismic exploration analysis (diffraction stacking method). In the examination, a CDP stacking method and the diffraction stacking method were compared through numerical experiments in the case of imaging a flat reflection surface and an irregular reflection surface. As a result, it was revealed that the CDP stacking method for stacking mirror reflection waves was merely a processing to raise S/N ratio while the diffraction stacking method for stacking with scattered waves assumed contained a migrational aspect as well as an aspect to raise S/N ratio. Consequently, it was shown that, if an oscillator was properly arranged, a structural imaging was possible not by the shape of a reflection surface but by the diffraction stacking method. Additionally, the diffraction stacking method revealed that the imaging effect varied by frequency with the stacking effect decreased at high frequencies, and that no stacking effect decreased at low frequencies but resolution lowered in horizontal direction. 4 refs., 8 figs.

  18. Detection of diethylene glycol adulteration in propylene glycol--method validation through a multi-instrument collaborative study.

    Science.gov (United States)

    Li, Xiang; Arzhantsev, Sergey; Kauffman, John F; Spencer, John A

    2011-04-05

    Four portable NIR instruments from the same manufacturer that were nominally identical were programmed with a PLS model for the detection of diethylene glycol (DEG) contamination in propylene glycol (PG)-water mixtures. The model was developed on one spectrometer and used on other units after a calibration transfer procedure that used piecewise direct standardization. Although quantitative results were produced, in practice the instrument interface was programmed to report in Pass/Fail mode. The Pass/Fail determinations were made within 10s and were based on a threshold that passed a blank sample with 95% confidence. The detection limit was then established as the concentration at which a sample would fail with 95% confidence. For a 1% DEG threshold one false negative (Type II) and eight false positive (Type I) errors were found in over 500 samples measured. A representative test set produced standard errors of less than 2%. Since the range of diethylene glycol for economically motivated adulteration (EMA) is expected to be above 1%, the sensitivity of field calibrated portable NIR instruments is sufficient to rapidly screen out potentially problematic materials. Following method development, the instruments were shipped to different sites around the country for a collaborative study with a fixed protocol to be carried out by different analysts. NIR spectra of replicate sets of calibration transfer, system suitability and test samples were all processed with the same chemometric model on multiple instruments to determine the overall analytical precision of the method. The combined results collected for all participants were statistically analyzed to determine a limit of detection (2.0% DEG) and limit of quantitation (6.5%) that can be expected for a method distributed to multiple field laboratories. Published by Elsevier B.V.

  19. Implementation of gamma-ray instrumentation for solid solar system bodies using neutron activation method

    International Nuclear Information System (INIS)

    Litvak, M.L.; Golovin, D.V.; Jun, I.; Kozyrev, A.S.; Mitrofanov, I.G.; Sanin, A.B.; Shvetsov, V.N.; Timoshenko, G.N.; Zontikov, A.

    2016-01-01

    In this paper we present the results of ground tests performed with a flight model and with industry prototypes of passive and active gamma ray spectrometers with the objective of understanding their capability to distinguish the elemental composition of planetary bodies in the solar system. The gamma instrumentation, which was developed for future space missions was used in the measurements at a special ground test facility where a simulant of planetary material was fabricated with a martian-like composition. In this study, a special attention was paid to the gamma lines from activation reaction products generated by a pulsed neutron generator. The instrumentation was able to detect and identify gamma lines attributed to O, Na, Mg, Al, Si, K, Ca and Fe.

  20. Solar EUV/FUV line polarimetry. I - Observational parameters and theoretical considerations. II - Instruments and methods

    Science.gov (United States)

    Fineschi, Silvano; Hoover, Richard B.; Fontenla, Juan M.; Walker, Arthur B. C., Jr.

    1991-01-01

    The paper discusses theoretical considerations and presents the observational parameters for the development of reflective FUV coronagraph/polarimeter and EUV imaging polarimeter instruments. New EUV/FUV polarimeter instrument concepts for solar research are described. One of these is a new coronagraph/polarimeter operating at 1215.6 A, which could observe the neutral hydrogen Ly-alpha line in the near solar corona and lead to the first direct measurements of both the strength and the direction of coronal magnetic fields. The other is a new multilayer EUV imaging polarimeter, operating at the wavelengths of strong He emission lines, which could observe impact polarization phenomena and provide information concerning the relative importance of thermal and nonthermal processes in solar flares.

  1. Turbulence study in the vicinity of piano key weir: relevance, instrumentation, parameters and methods

    Science.gov (United States)

    Tiwari, Harinarayan; Sharma, Nayan

    2017-05-01

    This research paper focuses on the need of turbulence, instruments reliable to capture turbulence, different turbulence parameters and some advance methodology which can decompose various turbulence structures at different levels near hydraulic structures. Small-scale turbulence research has valid prospects in open channel flow. The relevance of the study is amplified as we introduce any hydraulic structure in the channel which disturbs the natural flow and creates discontinuity. To recover this discontinuity, the piano key weir (PKW) might be used with sloped keys. Constraints of empirical results in the vicinity of PKW necessitate extensive laboratory experiments with fair and reliable instrumentation techniques. Acoustic Doppler velocimeter was established to be best suited within range of some limitations using principal component analysis. Wavelet analysis is proposed to decompose the underlying turbulence structure in a better way.

  2. A rapid instrumental neutron activation method for multielement content of some Egyptian phosphate minerals

    International Nuclear Information System (INIS)

    Guirguis, L.A.; Noweir, T.M.; El-Kady, A.A.

    1979-01-01

    An instrumental neutron activation analysis technique has been applied to some Egyptian phosphate minerals. The following 24 elements have been quantitatively determined. Sc, Cr, Fe, Co, As, Sr, Zr, Nb, Ag, Sn, Te, Ba, La, Ce, Nd, Eu, Tb, Ho, Yb, Lu, Hf, Ta, Ir and U. The observed distribution and abundance of some of the above elements could help in the proper evaluation of conditions of deposition and origin of their phosphate minerals

  3. Evaluation of Beeswax Influence on Physical Properties of Lipstick Using Instrumental and Sensory Methods

    OpenAIRE

    Kasparaviciene, Giedre; Savickas, Arunas; Kalveniene, Zenona; Velziene, Saule; Kubiliene, Loreta; Bernatoniene, Jurga

    2016-01-01

    The aim of this study was to optimize the lipsticks formulation according to the physical properties and sensory attributes and investigate the relationship between instrumental and sensory analyses and evaluate the influence of the main ingredients, beeswax and oil, with analysis of lipsticks properties. Central composite design was used to optimize the mixture of oils and beeswax and cocoa butter for formulation of lipsticks. Antioxidant activity was evaluated by DPPH free radical scavengin...

  4. Methods and Models of Market Risk Stress-Testing of the Portfolio of Financial Instruments

    Directory of Open Access Journals (Sweden)

    Alexander M. Karminsky

    2015-01-01

    Full Text Available Amid instability of financial markets and macroeconomic situation the necessity of improving bank risk-management instrument arises. New economic reality defines the need for searching for more advanced approaches of estimating banks vulnerability to exceptional, but plausible events. Stress-testing belongs to such instruments. The paper reviews and compares the models of market risk stress-testing of the portfolio of different financial instruments. These days the topic of the paper is highly acute due to the fact that now stress-testing is becoming an integral part of anticrisis risk-management amid macroeconomic instability and appearance of new risks together with close interest to the problem of risk-aggregation. The paper outlines the notion of stress-testing and gives coverage of goals, functions of stress-tests and main criteria for market risk stress-testing classification. The paper also stresses special aspects of scenario analysis. Novelty of the research is explained by elaborating the programme of aggregated complex multifactor stress-testing of the portfolio risk based on scenario analysis. The paper highlights modern Russian and foreign models of stress-testing both on solo-basis and complex. The paper lays emphasis on the results of stress-testing and revaluations of positions for all three complex models: methodology of the Central Bank of stress-testing portfolio risk, model relying on correlations analysis and copula model. The models of stress-testing on solo-basis are different for each financial instrument. Parametric StressVaR model is applicable to shares and options stress-testing;model based on "Grek" indicators is used for options; for euroobligation regional factor model is used. Finally some theoretical recommendations about managing market risk of the portfolio are given.

  5. [Development of methods and instruments for external quality assurance in inpatient parent-child rehabilitation and prevention].

    Science.gov (United States)

    Neuderth, S; Lukasczik, M; Musekamp, G; Gerlich, C; Saupe-Heide, M; Löbmann, R; Vogel, H

    2013-02-01

    There so far is no standardized program for external quality assurance in inpatient parent-child prevention and rehabilitation in Germany. Therefore, instruments and methods of external quality assurance were developed and evaluated on behalf of the federal-level health insurance institutions. On the level of structure quality, a modular questionnaire for assessing structural features of rehabilitation/prevention centers, basic and allocation criteria as well as a checklist for visitations were developed. Structural data were collected in a nationwide survey of parent-child prevention and rehabilitation centers. Process and outcome quality data were collected in n=38 centers. Process quality was assessed using multiple methods (process-related structural features, case-related routine documentation, and incident-related patient questionnaires). Outcome quality was measured via patient questionnaires (n=1 799 patients). We used a multi-level modelling approach by adjusting relevant confounders on institutional and patient levels. The methods, instruments and analyzing procedures developed for measuring quality on the level of structure, processes and outcomes were adjusted in cooperation with all relevant stakeholders. Results are exemplarily presented for all quality assurance tools. For most of the risk-adjusted outcome parameters, we found no significant differences between institutions. For the first time, a comprehensive, standardized and generally applicable set of methods and instruments for routine use in comparative quality measurement of inpatient parent-child prevention and rehabilitation is available. However, it should be considered that the very heterogeneous field of family-oriented measures can not be covered entirely by an external quality assurance program. Therefore, methods and instruments have to be adapted continuously to the specifics of this area of health care and to new developments. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Method for controlling a coolant liquid surface of cooling system instruments in an atomic power plant

    International Nuclear Information System (INIS)

    Monta, Kazuo.

    1974-01-01

    Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an overflow pipe in its inner cylindrical portion or down-comer, thereby minimizing variation in coolant inventory of the entire coolant due to loads thus minimizing variation in varied speed of the coolant. (Kamimura, M.)

  7. Development and durability of SOFC stacks

    Energy Technology Data Exchange (ETDEWEB)

    Beeaff, D.; Dinesen, A.R.; Mikkelsen, Lars; Nielsen, Karsten A.; Solvang, M.; Hendriksen, Peter V.

    2004-12-01

    The present project is a part of the Danish SOFC programme, which has the overall aim of establishing a Danish production of SOFC - cells, stacks and systems for economical and environmentally friendly power production. The aim of the present project was to develop and demonstrate (on a small scale, few cells, few thousand hours) a durable, thermally cyclable stack with high performance at 750 deg. C. Good progress towards this target has been made and demonstrated at the level of stack-elements (one cell between two interconnects) or small stacks (3 5 cells). Three different stacks or stack-elements have been operated for periods exceeding 3000 hr. The work has covered development of stack-components (seals, interconnects, coatings, contact layers), establishment of procedures for stack assembly and initiation, and detailed electrical characterisation with the aims of identifying performance limiting factors as well as long term durability. Further, post test investigations have been carried out to identify possible degradation mechanisms. (BA)

  8. Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

    Science.gov (United States)

    Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas

    2016-11-01

    This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real

  9. Is non-woven fabric a useful method of packaging instruments for operation theatres in resource constrained settings?

    OpenAIRE

    G S Devadiga; VMP Thomas; S Shetty; M S Setia

    2015-01-01

    Introduction: Studies have highlighted the advantages and disadvantages of woven and non-woven fabrics. The present study assessed the change in resterilisation proportion after introduction of non-woven fabric for packaging of instruments and to evaluate the cost-effectiveness of non-woven fabrics compared with woven fabrics. Materials and Methods: The present study is a secondary data analysis of resterilisation data collected from November 2009 to August 2013. We calculated the proportions...

  10. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  11. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  12. Cultural Heritage Digitalization on Traditional Sundanese Music Instrument Using Augmented Reality Markerless Marker Method

    Directory of Open Access Journals (Sweden)

    Budi Arifitama

    2017-07-01

    Full Text Available Research into cultural heritage which implements augmented reality technology is limited. Most recent research on cultural heritage are limited on storing data and information in the form of databases, this creates a disadvantage for people who wants to see and feel at the same moment on actual cultural heritage objects. This paper, proposes a solution which could merge the existing cultural object with people using augmented reality technology. This technology would preserve traditional instrument in the form of 3D object which can be digitally protected. The result showed that the use of augmented reality on preserving cultural heritage would benefit people who try to protect their culture.

  13. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  14. Dulce de Leche, a typical product of Latin America: characterisation by physicochemical, optical and instrumental methods.

    Science.gov (United States)

    Gaze, L V; Costa, M P; Monteiro, M L G; Lavorato, J A A; Conte Júnior, C A; Raices, R S L; Cruz, A G; Freitas, M Q

    2015-02-15

    The physicochemical profile of Dulce de Leche (DL) was determined by both routine analysis and others techniques (HPLC, GC-MS and ICP-OES). Seven Brazilian commercial brands were characterised for moisture content, protein, fat, ash, pH and titratable acidity, mineral content (sodium, potassium, calcium, and phosphorus), colour parameters and instrumental analysis (carbohydrates content and volatile compounds). Overall, extensive variability among all the parameters evaluated were observed, suggesting different operational procedures in the dairy factories along the DL processing. In this sense, an increase of intrinsic quality of DL is related closely the standardization of operational parameters using during the manufacture. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. A systematic review of statistical methods used to test for reliability of medical instruments measuring continuous variables.

    Science.gov (United States)

    Zaki, Rafdzah; Bulgiba, Awang; Nordin, Noorhaire; Azina Ismail, Noor

    2013-06-01

    Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice. In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. The Intra-class Correlation Coefficient (ICC) is the most popular method with 25 (60%) studies having used this method followed by the comparing means (8 or 19%). Out of 25 studies using the ICC, only 7 (28%) reported the confidence intervals and types of ICC used. Most studies (71%) also tested the agreement of instruments. This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  16. Cellulite: poor correlation between instrumental methods and photograph evaluation for severity classification.

    Science.gov (United States)

    Soares, J L M; Miot, H A; Sanudo, A; Bagatin, E

    2015-02-01

    Cellulite refers to skin relief alterations in women's thighs and buttocks, causing dissatisfaction and search for treatment. Its physiopathology is complex and not completely understood. Many therapeutic options have been reported with no scientific evidence about benefits. The majority of the studies are not controlled nor randomized; most efficacy endpoints are subjective, like not well-standardized photographs and investigator opinion. Objective measures could improve severity assessment. Our purpose was to correlate non-invasive instrumental measures and standardized clinical evaluation. Twenty six women presenting cellulite on buttocks, aged from 25 to 41, were evaluated by: body mass index; standardized photography analysis (10-point severity and 5-point photonumeric scales) by five dermatologists; cutometry and high-frequency ultrasonography (dermal density and dermis/hypodermis interface length). Quality of life impact was assessed. Correlations between clinical and instrumental parameters were performed. Good agreement among dermatologists and main investigator perceptions was detected. Positive correlations: body mass index and clinical scores; ultrasonographic measures. Negative correlation: cutometry and clinical scores. Quality of life score was correlated to dermal collagen density. Cellulite caused impact in quality of life. Poor correlation between objective measures and clinical evaluation was detected. Cellulite severity assessment is a challenge, and objective parameters should be optimized for clinical trials. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Two on-line methods for routine testing of neutron and temperature instrumentation of power reactors

    International Nuclear Information System (INIS)

    Edelmann, M.

    1976-07-01

    The testing procedures proposed and described use inherent fluctuations or modulations of the physical quantities being measured as dynamic test input to the whole signal channel. They can be applied therefore during normal reactor operation at power. Signal channel performance information is obtained from the fluctuations of the available signals only using simplified noise analysis techniques. Neutron instrumentation testing is based on the prompt jump in reactor power subsequent to single reactivity steps produced by the control system during normal operation to keep the power at the prescribed level. For testing of outlet temperature instrumentation (thermocouples) a different procedure is necessary. The relationship between temperature and power noise is used. It was found that the ratio of the maximum value of the cross correlation function between neutron and temperature noise signals normalized to the rms value of the neutron noise is a suitable quantity for monitoring. Monitoring with small and large averaging time constants simultaneously enables quick indication of suddenly occuring significant failure and detection of small changes of the response characteristics, respectively. (orig.) [de

  18. New methodical and instrumental developments in laser ablation inductively coupled plasma mass spectrometry1

    Science.gov (United States)

    Hoffmann, E.; Lüdke, C.; Skole, J.; Stephanowitz, H.; Wollbrandt, J.; Becker, W.

    2002-10-01

    Many tasks in bulk analysis, micro analysis and depth profile analysis can be solved advantageously by laser ablation inductively coupled plasma mass spectrometry (Laser ICP-MS) in particular, when both the chemical and elemental distributions in the sample are to be determined. However, the analyst has to take into account that the analytical precision and accuracy of the Laser ICP-MS is influenced decisively by signal standardization, the homogeneity of the samples as well as calibration standards and the mass-spectrometric measuring mode, which is usually sequential when performed with scanning mass spectrometers such as quadrupol- or sector-based instruments. Using the ablated mass as standard, an excellent level of the analytical precision and accuracy (relative standard deviation R.S.D.ASIC) was developed, which permits a time resolution of 1 ns. The analytical performance of the TOF when used in combination with an ICP is demonstrated in terms of resolution, ion extraction rate, detection limits and dynamic range. The determination of 39K + and 40Ca + at trace level can be realized in a cool plasma condition (high central gas flow) only with a small interference by 40Ar +. Detection limits of 23 elements were measured with typical values in the lower nanograms per liter range. The ion extraction rates, measured for a sample mass of 1 ng in terms of counts per second divided by the relative isotope abundance, are one order of magnitude higher than those obtained with a quadrupol-based instrument.

  19. A development and integration of the concentration database for relative method, k0 method and absolute method in instrumental neutron activation analysis using Microsoft Access

    International Nuclear Information System (INIS)

    Hoh Siew Sin

    2012-01-01

    Instrumental Neutron Activation Analysis (INAA) is offen used to determine and calculate the concentration of an element in the sample by the National University of Malaysia, especially students of Nuclear Science Program. The lack of a database service leads consumers to take longer time to calculate the concentration of an element in the sample. This is because we are more dependent on software that is developed by foreign researchers which are costly. To overcome this problem, a study has been carried out to build an INAA database software. The objective of this study is to build a database software that help the users of INAA in Relative Method and Absolute Method for calculating the element concentration in the sample using Microsoft Excel 2010 and Microsoft Access 2010. The study also integrates k 0 data, k 0 Concent and k 0 -Westcott to execute and complete the system. After the integration, a study was conducted to test the effectiveness of the database software by comparing the concentrations between the experiments and in the database. Triple Bare Monitor Zr-Au and Cr-Mo-Au were used in Abs-INAA as monitor to determine the thermal to epithermal neutron flux ratio (f). Calculations involved in determining the concentration are the net peak area (N p ), the measurement time (t m ), the irradiation time (t irr ), k-factor (k), thermal to epithermal neutron flux ratio (f), the parameters of the neutron flux distribution epithermal (α) and detection efficiency (ε p ). For Com-INAA databases, reference material IAEA-375 Soil was used to calculate the concentration of elements in the sample. CRM, SRM are also used in this database. After the INAA database integration, a verification process was to examine the effectiveness of the Abs-INAA was carried out by comparing the sample concentration between the in database and the experiment. The result of the experimental concentration value of INAA database software performed with high accuracy and precision. ICC

  20. Nuclear medicine and imaging research. Instrumentation and quantitative methods of evaluation. Progress report, January 15, 1984-January 14, 1985

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1984-09-01

    This program addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. Project I addresses problems associated with the quantitative imaging of single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures

  1. Lightweight Stacks of Direct Methanol Fuel Cells

    Science.gov (United States)

    Narayanan, Sekharipuram; Valdez, Thomas

    2004-01-01

    An improved design concept for direct methanol fuel cells makes it possible to construct fuel-cell stacks that can weigh as little as one-third as much as do conventional bipolar fuel-cell stacks of equal power. The structural-support components of the improved cells and stacks can be made of relatively inexpensive plastics. Moreover, in comparison with conventional bipolar fuel-cell stacks, the improved fuel-cell stacks can be assembled, disassembled, and diagnosed for malfunctions more easily. These improvements are expected to bring portable direct methanol fuel cells and stacks closer to commercialization. In a conventional bipolar fuel-cell stack, the cells are interspersed with bipolar plates (also called biplates), which are structural components that serve to interconnect the cells and distribute the reactants (methanol and air). The cells and biplates are sandwiched between metal end plates. Usually, the stack is held together under pressure by tie rods that clamp the end plates. The bipolar stack configuration offers the advantage of very low internal electrical resistance. However, when the power output of a stack is only a few watts, the very low internal resistance of a bipolar stack is not absolutely necessary for keeping the internal power loss acceptably low.

  2. Stacking fault growth of FCC crystal: The Monte-Carlo simulation approach

    International Nuclear Information System (INIS)

    Jian Jianmin; Ming Naiben

    1988-03-01

    The Monte-Carlo method has been used to simulate the growth of the FCC (111) crystal surface, on which is presented the outcrop of a stacking fault. The comparison of the growth rates has been made between the stacking fault containing surface and the perfect surface. The successive growth stages have been simulated. It is concluded that the outcrop of stacking fault on the crystal surface can act as a self-perpetuating step generating source. (author). 7 refs, 3 figs

  3. Microhardness with depth sensing indentation. Instruments methods and applications; Mesure de durete submicronique instrumentee. Methode et applications

    Energy Technology Data Exchange (ETDEWEB)

    Poissonnet, S

    1999-07-01

    The study of applied surface layer or modified layers lead to the development of depth sensing indentation instruments in which measurements of penetration depth replaces optical measurements of surface impressions and sub-micron hardness may be determined. Indentation curves, depth-load, of elastoplastic materials give informations about plasticity and elasticity. After a description of the micro-indentation techniques we show few applications. Irradiation effects are measured in different materials like hafnium diboride, stainless steel or kapton. Hardness in oxide formed on metal study give informations. All these examples show that the nano-indentation is a powerful mean in the physical studies of materials because of a good statistic may be obtained and we have access to thin samples and to small phases. (author)

  4. Solid Oxide Fuel Cell Stack Diagnostics

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Barfod, Rasmus Gottrup

    . An operating stack is subject to compositional gradients in the gaseous reactant streams, and temperature gradients across each cell and across the stack, which complicates detailed analysis. Several experimental stacks from Topsoe Fuel Cell A/S were characterized using Electrochemical Impedance Spectroscopy...... (EIS). The stack measurement geometry was optimized for EIS by careful selection of the placement of current feeds and voltage probes in order to minimize measurement errors. It was demonstrated that with the improved placement of current feeds and voltage probes it is possible to separate the loss...... in the hydrogen fuel gas supplied to the stack. EIS was used to examine the long-term behavior and monitor the evolution of the impedance of each of the repeating units and the whole stack. The observed impedance was analyzed in detail for one of the repeating units and the whole stack and the losses reported...

  5. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.

    2008-12-17

    This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

  6. Online calibration method for condition monitoring of nuclear reactor instrumentations based on electrical signature analysis

    International Nuclear Information System (INIS)

    Syaiful Bakhri

    2013-01-01

    Electrical signature analysis currently becomes an alternative in condition monitoring in nuclear power plants not only for stationary components such as sensors, measurement and instrumentation channels, and other components but also for dynamic components such as electric motors, pumps, generator or actuators. In order to guarantee the accuracy, the calibration of monitoring system is a necessary which practically is performed offline, under limited schedules and certain tight procedures. This research aims to introduce online calibration technique for electrical signature condition monitoring in order that the accuracy can be maintained continuously which in turn increases the reactor safety as a whole. The research was performed step by stepin detail from the conventional technique, online calibration using baseline information and online calibration using differential gain adjustment. Online calibration based on differential gain adjustment provides better results than other techniques even tough under extreme gain insertion as well as external disturbances such as supply voltages. (author)

  7. Generalized diffraction-stack migration and filtering of coherent noise

    KAUST Repository

    Zhan, Ge

    2014-01-27

    We reformulate the equation of reverse-time migration so that it can be interpreted as summing data along a series of hyperbola-like curves, each one representing a different type of event such as a reflection or multiple. This is a generalization of the familiar diffraction-stack migration algorithm where the migration image at a point is computed by the sum of trace amplitudes along an appropriate hyperbola-like curve. Instead of summing along the curve associated with the primary reflection, the sum is over all scattering events and so this method is named generalized diffraction-stack migration. This formulation leads to filters that can be applied to the generalized diffraction-stack migration operator to mitigate coherent migration artefacts due to, e.g., crosstalk and aliasing. Results with both synthetic and field data show that generalized diffraction-stack migration images have fewer artefacts than those computed by the standard reverse-time migration algorithm. The main drawback is that generalized diffraction-stack migration is much more memory intensive and I/O limited than the standard reverse-time migration method. © 2014 European Association of Geoscientists & Engineers.

  8. Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

    Science.gov (United States)

    Chipera, S. J.; Vaniman, D. T.; Bish, D. L.; Sarrazin, P.; Feldman, S.; Blake, D. F.; Bearman, G.; Bar-Cohen, Y.

    2004-01-01

    A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

  9. Stacked generalization: an introduction to super learning.

    Science.gov (United States)

    Naimi, Ashley I; Balzer, Laura B

    2018-04-10

    Stacked generalization is an ensemble method that allows researchers to combine several different prediction algorithms into one. Since its introduction in the early 1990s, the method has evolved several times into a host of methods among which is the "Super Learner". Super Learner uses V-fold cross-validation to build the optimal weighted combination of predictions from a library of candidate algorithms. Optimality is defined by a user-specified objective function, such as minimizing mean squared error or maximizing the area under the receiver operating characteristic curve. Although relatively simple in nature, use of Super Learner by epidemiologists has been hampered by limitations in understanding conceptual and technical details. We work step-by-step through two examples to illustrate concepts and address common concerns.

  10. Piezoelectric stack actuator parameter extraction with hysteresis compensation

    DEFF Research Database (Denmark)

    Zsurzsan, Tiberiu-Gabriel; Mangeot, Charles; Andersen, Michael A. E.

    2014-01-01

    The Piezoelectric Actuator Drive (PAD) is a type of rotary motor that transforms the linear motion of piezoelectric stack actuators into a precise rotational motion. The very high stiffness of the actuators employed make this type of motor suited for open-loop control, but the inherent hysteresis...... exhibited by piezoelectric ceramics causes losses. Therefore, this paper presents a straightforward method to measure piezoelectric stack actuator equiv- alent parameters that includes nonlinearities. By folding the nonlinearities into a newly-defined cou- pling coefficient, the inherent hysteretic behavior...... of piezoelectric stack actuators can be greatly reduced through precompensation. Experimental results show a fitting accuracy of 98.8 % between the model and measurements and a peak absolute error reduction by a factor of 10 compared to the manufacturer- provided parameter. This method improves both the static...

  11. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-05-27

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

  12. Music Used for Parkinson’s Dancing Classes: Rationale and Validity or Instruments and Methods

    OpenAIRE

    Winifred A. Beevers; Meg E Morris; Janet McConville

    2015-01-01

    Music has the potential to motivate, support and improve exercise performance while reducing the perceptions of fatigue. The music used in exercise groups is rarely examined in detail. This article is an investigation into finding existing methods for analysing recorded music as used in exercise groups. No single method or tool was identified. Existing music analysis methods focus on music that is heard or performed in the therapy session, and are used to facilitate discussion and interpr...

  13. Generalized stacking fault energies of alloys.

    Science.gov (United States)

    Li, Wei; Lu, Song; Hu, Qing-Miao; Kwon, Se Kyun; Johansson, Börje; Vitos, Levente

    2014-07-02

    The generalized stacking fault energy (γ surface) provides fundamental physics for understanding the plastic deformation mechanisms. Using the ab initio exact muffin-tin orbitals method in combination with the coherent potential approximation, we calculate the γ surface for the disordered Cu-Al, Cu-Zn, Cu-Ga, Cu-Ni, Pd-Ag and Pd-Au alloys. Studying the effect of segregation of the solute to the stacking fault planes shows that only the local chemical composition affects the γ surface. The calculated alloying trends are discussed using the electronic band structure of the base and distorted alloys.Based on our γ surface results, we demonstrate that the previous revealed 'universal scaling law' between the intrinsic energy barriers (IEBs) is well obeyed in random solid solutions. This greatly simplifies the calculations of the twinning measure parameters or the critical twinning stress. Adopting two twinnability measure parameters derived from the IEBs, we find that in binary Cu alloys, Al, Zn and Ga increase the twinnability, while Ni decreases it. Aluminum and gallium yield similar effects on the twinnability.

  14. Instrumentation device at the outside of reactor and method of using the same

    International Nuclear Information System (INIS)

    Ichige, Masayuki.

    1997-01-01

    The present invention provides instrumentation device at the outside of a reactor capable of measuring conditions of inside of a reactor, such as the power of the reactor, distribution of voids or water level while considering hysteresis of neutrons or γ-rays from the inside to the outside of the reactor. Namely, a plurality of radiation detectors are disposed being elongated in vertical direction at a predetermined distance on the outer circumference of a reactor pressure vessel. The detectors detect intensity of radiation rays and the detection time at a plurality of positions of the outer side of the reactor. An amplifier amplifies the detected signals. A signal processing device determines the positions and the time of the emitted radiation rays based on the amplified detected signals. An analysis device analyzes spacial distribution and time distribution of the energy and the intensity of the radiation rays (neutron or γ-rays) based on the signals of predetermined radiation rays at the outer side of the reactor. Then, spacial and time variation components and the power distribution, water level, change of the water level, void distribution are calculated while considering decay of the radiation rays based on the distribution of material densities of incore structures. (I.S.)

  15. Portable dynamic light scattering instrument and method for the measurement of blood platelet suspensions

    International Nuclear Information System (INIS)

    Maurer-Spurej, Elisabeth; Brown, Keddie; Labrie, Audrey; Marziali, Andre; Glatter, Otto

    2006-01-01

    No routine test exists to determine the quality of blood platelet transfusions although every year millions of patients require platelet transfusions to survive cancer chemotherapy, surgery or trauma. A new, portable dynamic light scattering instrument is described that is suitable for the measurement of turbid solutions of large particles under temperature-controlled conditions. The challenges of small sample size, short light path through the sample and accurate temperature control have been solved with a specially designed temperature-controlled sample holder for small diameter, disposable capillaries. Efficient heating and cooling is achieved with Peltier elements in direct contact with the sample capillary. Focusing optical fibres are used for light delivery and collection of scattered light. The practical use of this new technique was shown by the reproducible measurement of latex microspheres and the temperature-induced morphological changes of human blood platelets. The measured parameters for platelet transfusions are platelet size, number of platelet-derived microparticles and the response of platelets to temperature changes. This three-dimensional analysis provides a high degree of confidence for the determination of platelet quality. The experimental data are compared to a matrix and facilitate automated, unbiased quality testing

  16. Preference-based disease-specific health-related quality of life instrument for glaucoma: a mixed methods study protocol.

    Science.gov (United States)

    Muratov, Sergei; Podbielski, Dominik W; Jack, Susan M; Ahmed, Iqbal Ike K; Mitchell, Levine A H; Baltaziak, Monika; Xie, Feng

    2016-11-08

    A primary objective of healthcare services is to improve patients' health and health-related quality of life (HRQoL). Glaucoma, which affects a substantial proportion of the world population, has a significant detrimental impact on HRQoL. Although there are a number of glaucoma-specific questionnaires to measure HRQoL, none is preference-based which prevent them from being used in health economic evaluation. The proposed study is aimed to develop a preference-based instrument that is capable of capturing important effects specific to glaucoma and treatments on HRQoL and is scored based on the patients' preferences. A sequential, exploratory mixed methods design will be used to guide the development and evaluation of the HRQoL instrument. The study consists of several stages to be implemented sequentially: item identification, item selection, validation and valuation. The instrument items will be identified and selected through a literature review and the conduct of a qualitative study. Validation will be conducted to establish psychometric properties of the instrument followed by a valuation exercise to derive utility scores for the health states described. This study has been approved by the Trillium Health Partners Research Ethics Board (ID number 753). All personal information will be de-identified with the identification code kept in a secured location including the rest of the study data. Only qualified and study-related personnel will be allowed to access the data. The results of the study will be distributed widely through peer-reviewed journals, conferences and internal meetings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. ZPEG: a hybrid DPCM-DCT based approach for compression of Z-stack images.

    Science.gov (United States)

    Khire, Sourabh; Cooper, Lee; Park, Yuna; Carter, Alexis; Jayant, Nikil; Saltz, Joel

    2012-01-01

    Modern imaging technology permits obtaining images at varying depths along the thickness, or the Z-axis of the sample being imaged. A stack of multiple such images is called a Z-stack image. The focus capability offered by Z-stack images is critical for many digital pathology applications. A single Z-stack image may result in several hundred gigabytes of data, and needs to be compressed for archival and distribution purposes. Currently, the existing methods for compression of Z-stack images such as JPEG and JPEG 2000 compress each focal plane independently, and do not take advantage of the Z-signal redundancy. It is possible to achieve additional compression efficiency over the existing methods, by exploiting the high Z-signal correlation during image compression. In this paper, we propose a novel algorithm for compression of Z-stack images, which we term as ZPEG. ZPEG extends the popular discrete-cosine transform (DCT) based image encoder to compress Z-stack images. This is achieved by decorrelating the neighboring layers of the Z-stack image using differential pulse-code modulation (DPCM). PSNR measurements, as well as subjective evaluations by experts indicate that ZPEG can encode Z-stack images at a higher quality as compared to JPEG, JPEG 2000 and JP3D at compression ratios below 50∶1.

  18. Using cognitive pre-testing methods in the development of a new evidenced-based pressure ulcer risk assessment instrument

    Directory of Open Access Journals (Sweden)

    S. Coleman

    2016-11-01

    Full Text Available Abstract Background Variation in development methods of Pressure Ulcer Risk Assessment Instruments has led to inconsistent inclusion of risk factors and concerns about content validity. A new evidenced-based Risk Assessment Instrument, the Pressure Ulcer Risk Primary Or Secondary Evaluation Tool - PURPOSE-T was developed as part of a National Institute for Health Research (NIHR funded Pressure Ulcer Research Programme (PURPOSE: RP-PG-0407-10056. This paper reports the pre-test phase to assess and improve PURPOSE-T acceptability, usability and confirm content validity. Methods A descriptive study incorporating cognitive pre-testing methods and integration of service user views was undertaken over 3 cycles comprising PURPOSE-T training, a focus group and one-to-one think-aloud interviews. Clinical nurses from 2 acute and 2 community NHS Trusts, were grouped according to job role. Focus group participants used 3 vignettes to complete PURPOSE-T assessments and then participated in the focus group. Think-aloud participants were interviewed during their completion of PURPOSE-T. After each pre-test cycle analysis was undertaken and adjustment/improvements made to PURPOSE-T in an iterative process. This incorporated the use of descriptive statistics for data completeness and decision rule compliance and directed content analysis for interview and focus group data. Data were collected April 2012-June 2012. Results Thirty-four nurses participated in 3 pre-test cycles. Data from 3 focus groups, 12 think-aloud interviews incorporating 101 PURPOSE-T assessments led to changes to improve instrument content and design, flow and format, decision support and item-specific wording. Acceptability and usability were demonstrated by improved data completion and appropriate risk pathway allocation. The pre-test also confirmed content validity with clinical nurses. Conclusions The pre-test was an important step in the development of the preliminary PURPOSE-T and the

  19. Characteristic and Competency Measurement Instrument Development for Maintenance Staff of Mechanical Expertise with SECI Method: A Case of Manufacturing Company

    Science.gov (United States)

    Mahatmavidya, P. A.; Soesanto, R. P.; Kurniawati, A.; Andrawina, L.

    2018-03-01

    Human resource is an important factor for a company to gain competitiveness, therefore competencies of each individual in a company is a basic characteristic that is taken into account. The increasing employee’s competency will affect directly to the company's performance. The purpose of this research is to improve the quality of human resources of maintenance staff in manufacturing company by designing competency measurement instrument that aims to assess the competency of employees. The focus of this research is the mechanical expertise of maintenance staff. SECI method is used in this research for managing knowledge that is held by senior employees regarding employee competence of mechanical expertise. The SECI method converts the knowledge of a person's tacit knowledge into an explicit knowledge so that the knowledge can be used by others. The knowledge that is gathered from SECI method is converted into a list of competence and break down into the detailed competency. Based on the results of this research, it is known that 11 general competencies, 17 distinctive competencies, 20 indicators, and 20 item list for assessing the competencies are developed. From the result of competency breakdown, the five-level instrument of measurement is designed which can assist in assessing employee’s competency for mechanical expertise.

  20. Vertically stacked nanocellulose tactile sensor.

    Science.gov (United States)

    Jung, Minhyun; Kim, Kyungkwan; Kim, Bumjin; Lee, Kwang-Jae; Kang, Jae-Wook; Jeon, Sanghun

    2017-11-16

    Paper-based electronic devices are attracting considerable attention, because the paper platform has unique attributes such as flexibility and eco-friendliness. Here we report on what is claimed to be the firstly fully integrated vertically-stacked nanocellulose-based tactile sensor, which is capable of simultaneously sensing temperature and pressure. The pressure and temperature sensors are operated using different principles and are stacked vertically, thereby minimizing the interference effect. For the pressure sensor, which utilizes the piezoresistance principle under pressure, the conducting electrode was inkjet printed on the TEMPO-oxidized-nanocellulose patterned with micro-sized pyramids, and the counter electrode was placed on the nanocellulose film. The pressure sensor has a high sensitivity over a wide range (500 Pa-3 kPa) and a high durability of 10 4 loading/unloading cycles. The temperature sensor combines various materials such as poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), silver nanoparticles (AgNPs) and carbon nanotubes (CNTs) to form a thermocouple on the upper nanocellulose layer. The thermoelectric-based temperature sensors generate a thermoelectric voltage output of 1.7 mV for a temperature difference of 125 K. Our 5 × 5 tactile sensor arrays show a fast response, negligible interference, and durable sensing performance.

  1. Generalized data stacking programming model with applications

    Directory of Open Access Journals (Sweden)

    Hala Samir Elhadidy

    2016-09-01

    Full Text Available Recent researches have shown that, everywhere in various sciences the systems are following stacked-based stored change behavior when subjected to events or varying environments “on and above” their normal situations. This paper presents a generalized data stack programming (GDSP model which is developed to describe the system changes under varying environment. These changes which are captured with different ways such as sensor reading are stored in matrices. Extraction algorithm and identification technique are proposed to extract the different layers between images and identify the stack class the object follows; respectively. The general multi-stacking network is presented including the interaction between various stack-based layering of some applications. The experiments prove that the concept of stack matrix gives average accuracy of 99.45%.

  2. Using cognitive pre-testing methods in the development of a new evidenced-based pressure ulcer risk assessment instrument.

    Science.gov (United States)

    Coleman, S; Nixon, J; Keen, J; Muir, D; Wilson, L; McGinnis, E; Stubbs, N; Dealey, C; Nelson, E A

    2016-11-16

    Variation in development methods of Pressure Ulcer Risk Assessment Instruments has led to inconsistent inclusion of risk factors and concerns about content validity. A new evidenced-based Risk Assessment Instrument, the Pressure Ulcer Risk Primary Or Secondary Evaluation Tool - PURPOSE-T was developed as part of a National Institute for Health Research (NIHR) funded Pressure Ulcer Research Programme (PURPOSE: RP-PG-0407-10056). This paper reports the pre-test phase to assess and improve PURPOSE-T acceptability, usability and confirm content validity. A descriptive study incorporating cognitive pre-testing methods and integration of service user views was undertaken over 3 cycles comprising PURPOSE-T training, a focus group and one-to-one think-aloud interviews. Clinical nurses from 2 acute and 2 community NHS Trusts, were grouped according to job role. Focus group participants used 3 vignettes to complete PURPOSE-T assessments and then participated in the focus group. Think-aloud participants were interviewed during their completion of PURPOSE-T. After each pre-test cycle analysis was undertaken and adjustment/improvements made to PURPOSE-T in an iterative process. This incorporated the use of descriptive statistics for data completeness and decision rule compliance and directed content analysis for interview and focus group data. Data were collected April 2012-June 2012. Thirty-four nurses participated in 3 pre-test cycles. Data from 3 focus groups, 12 think-aloud interviews incorporating 101 PURPOSE-T assessments led to changes to improve instrument content and design, flow and format, decision support and item-specific wording. Acceptability and usability were demonstrated by improved data completion and appropriate risk pathway allocation. The pre-test also confirmed content validity with clinical nurses. The pre-test was an important step in the development of the preliminary PURPOSE-T and the methods used may have wider instrument development application

  3. Aespoe Hard Rock Laboratory. Characterisation methods and instruments. Experiences from the construction phase

    International Nuclear Information System (INIS)

    Almen, Karl-Erik; Stenberg, Leif

    2005-12-01

    This report describes the different investigation methods used during the Aespoe HRL construction phase which commenced 1990 and ended 1995. The investigation methods are described with respect to performance, errors, uncertainty and usefulness in determined, analysed and/or calculated parameter values or other kind of geoscientific information. Moreover, other comments of the different methods, like those related to the practical performance of the measurements or tests are given. The practical performance is a major task as most of the investigations were conducted in parallel with the construction work. Much of the wide range of investigations carried out during the tunnelling work required special efforts of the personnel involved. Experiences and comments on these operations are presented in the report. The pre-investigation methods have been evaluated by comparing predictions based on pre-investigation models with data and results from the construction phase and updated geoscientific models. In 1997 a package of reports describe the general results of the pre-investigations. The investigation methods are in this report evaluated with respect to usefulness for underground characterisation of a rock volume, concerning geological, geohydrological, hydrochemical and rock mechanical properties. The report describes out opinion of the methods after the construction phase, i.e. the same platform of knowledge as for the package of reports of 1997. The evaluation of usefulness of the underground investigation methods are structured according to the key issues used for the preinvestigation modelling and predictions, i.e. Geological-structural model, Groundwater flow (hydrogeology), Groundwater chemistry (hydrochemistry), Transport of solutes and Mechanical stability models (or rock mechanics). The investigation methods selected for the different subjects for which the predictions were made are presented. Some of the subjects were slightly modified or adjusted during

  4. Aespoe Hard Rock Laboratory. Characterisation methods and instruments. Experiences from the construction phase

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    This report describes the different investigation methods used during the Aespoe HRL construction phase which commenced 1990 and ended 1995. The investigation methods are described with respect to performance, errors, uncertainty and usefulness in determined, analysed and/or calculated parameter values or other kind of geoscientific information. Moreover, other comments of the different methods, like those related to the practical performance of the measurements or tests are given. The practical performance is a major task as most of the investigations were conducted in parallel with the construction work. Much of the wide range of investigations carried out during the tunnelling work required special efforts of the personnel involved. Experiences and comments on these operations are presented in the report. The pre-investigation methods have been evaluated by comparing predictions based on pre-investigation models with data and results from the construction phase and updated geoscientific models. In 1997 a package of reports describe the general results of the pre-investigations. The investigation methods are in this report evaluated with respect to usefulness for underground characterisation of a rock volume, concerning geological, geohydrological, hydrochemical and rock mechanical properties. The report describes out opinion of the methods after the construction phase, i.e. the same platform of knowledge as for the package of reports of 1997. The evaluation of usefulness of the underground investigation methods are structured according to the key issues used for the preinvestigation modelling and predictions, i.e. Geological-structural model, Groundwater flow (hydrogeology), Groundwater chemistry (hydrochemistry), Transport of solutes and Mechanical stability models (or rock mechanics). The investigation methods selected for the different subjects for which the predictions were made are presented. Some of the subjects were slightly modified or adjusted during

  5. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  6. New teaching methods in use at UC Irvine's optical engineering and instrument design programs

    Science.gov (United States)

    Silberman, Donn M.; Rowe, T. Scott; Jo, Joshua; Dimas, David

    2012-10-01

    New teaching methods reach geographically dispersed students with advances in Distance Education. Capabilities include a new "Hybrid" teaching method with an instructor in a classroom and a live WebEx simulcast for remote students. Our Distance Education Geometric and Physical Optics courses include Hands-On Optics experiments. Low cost laboratory kits have been developed and YouTube type video recordings of the instructor using these tools guide the students through their labs. A weekly "Office Hour" has been developed using WebEx and a Live Webcam the instructor uses to display his live writings from his notebook for answering students' questions.

  7. Flexural characteristics of a stack leg

    International Nuclear Information System (INIS)

    Cook, J.

    1979-06-01

    A 30 MV tandem Van de Graaff accelerator is at present under construction at Daresbury Laboratory. The insulating stack of the machine is of modular construction, each module being 860 mm in length. Each live section stack module contains 8 insulating legs mounted between bulkhead rings. The design, fabrication (from glass discs bonded to stainless steel discs using an epoxy film adhesive) and testing of the stack legs is described. (U.K.)

  8. Use of instrumental nuclear activation methods in the study of particles from major air pollution sources

    International Nuclear Information System (INIS)

    Gordon, G.E.; Zoller, W.H.; Gladney, E.S.; Greenberg, R.R.

    1974-01-01

    Nuclear methods have been used effectively in the study of particles emitted by a coal-fired power plant and a municipal incinerator. In the coal-fired plant there is appreciable fractionation of only five of the observed elements. By contrast, particles from the incinerator are highly enriched in several trace elements

  9. Field instrumentation, monitoring of drilled shafts for landslide stabilization and development of pertinent design method.

    Science.gov (United States)

    2010-11-01

    The design method for using a single row, spaced drilled shafts, socketed into a firm rock strata, to stabilize : an unstable slope has been developed in this research. The soil arching due to the presence of spaced : drilled shafts in a slope was ob...

  10. Higuchi’s Method applied to detection of changes in timbre of digital sound synthesis of string instruments with the functional transformation method

    Science.gov (United States)

    Kanjanapen, Manorth; Kunsombat, Cherdsak; Chiangga, Surasak

    2017-09-01

    The functional transformation method (FTM) is a powerful tool for detailed investigation of digital sound synthesis by the physical modeling method, the resulting sound or measured vibrational characteristics at discretized points on real instruments directly solves the underlying physical effect of partial differential equation (PDE). In this paper, we present the Higuchi’s method to examine the difference between the timbre of tone and estimate fractal dimension of musical signals which contains information about their geometrical structure that synthesizes by FTM. With the Higuchi’s method we obtain the whole process is not complicated, fast processing, with the ease of analysis without expertise in the physics or virtuoso musicians and the easiest way for the common people can judge that sounds similarly presented.

  11. Nuclear medicine and imaging research. Instrumentation and quantitative methods of evaluation. Progress report, January 15, 1985-January 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This program of research addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation, and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. These developments are designed to meet the needs imposed by new radiopharmaceuticals developed to solve specific biomedical problems, as well as to meet the instrumentation needs associated with radiopharmaceutical production and quantitative clinical feasibility studies of the brain with PET VI. Project I addresses problems associated with the quantitative imaging of single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures. The original proposal covered work to be carried out over the three-year contract period. This report covers progress made during Year Three. 36 refs., 1 tab

  12. Model and Design of a Power Driver for Piezoelectric Stack Actuators

    Directory of Open Access Journals (Sweden)

    Chiaberge M

    2010-01-01

    Full Text Available A power driver has been developed to control piezoelectric stack actuators used in automotive application. An FEM model of the actuator has been implemented starting from experimental characterization of the stack and mechanical and piezoelectric parameters. Experimental results are reported to show a correct piezoelectric actuator driving method and the possibility to obtain a sensorless positioning control.

  13. A new instrumental method for the analysis of rare earth elements

    International Nuclear Information System (INIS)

    Santos, A.N. dos.

    1975-01-01

    A method for the simultaneous elemental analysis of the rare earths is proposed and empirically verified. It is based on the analysis of the escape peaks, generated by the characteristic X-rays of these elements in a xenon proportional counter. The peaks are well resolved and intense, in contrast to the photopeak which is lost in the background. The spectra are generated by a radioisotope such as Co 57 , and the equipment is simple, portable and low cost, although resolution challenges that of the best solid state detectors. Since X-rays are utilized, matrix, granulometric or mineralogical effects are minimal, and the method is rapid, sensitive, non-destructive and requires little or no sample preparation. The results are preliminary and an improvement in resolution of up to fourfold seems possible; precision is better than 0,1% in concentrated samples and sensitivity is about 20 μg

  14. INSTRUMENTS AND METHODS OF INVESTIGATION: Plasma isotope separation based on ion cyclotron resonance

    Science.gov (United States)

    Dolgolenko, Dmitrii A.; Muromkin, Yurii A.

    2009-04-01

    Experiments that have been conducted in the USA, France, and Russia to investigate isotopically selective ion cyclotron resonance (ICR) as a tool for plasma isotope separation are analyzed. Because this method runs into difficulties at low values of the relative isotope mass difference ΔM/M, for some elements (for gadolinium, as an example) isotope separation still remains a problem. There are ways to solve it, however, as experimental results and theoretical calculations suggest.

  15. The moderate resolution imaging spectrometer: An EOS facility instrument candidate for application of data compression methods

    Science.gov (United States)

    Salomonson, Vincent V.

    1991-01-01

    The Moderate Resolution Imaging Spectrometer (MODIS) observing facility will operate on the Earth Observing System (EOS) in the late 1990's. It is estimated that this observing facility will produce over 200 gigabytes of data per day requiring a storage capability of just over 300 gigabytes per day. Archiving, browsing, and distributing the data associated with MODIS represents a rich opportunity for testing and applying both lossless and lossy data compression methods.

  16. The SVM Method As An Instrument For The Classification Of Vertical Displacements

    Directory of Open Access Journals (Sweden)

    Mrówczyńska Maria

    2015-07-01

    Full Text Available The article presents the basic rules for constructing and training neural networks called the Support Vector Machine method as well as possible applications for this kind of network. SVM networks are mainly used for solving tasks of classifying linearly and non-linearly separable data and regression. However, in recent years more applications have been found for them. The networks also solve such problems as the recognition of signals and images as well as speech identification.

  17. SWATH-ID: An instrument method which combines identification and quantification in a single analysis.

    Science.gov (United States)

    Kang, Yang; Burton, Lyle; Lau, Adam; Tate, Stephen

    2017-04-07

    Data-independent acquisition (DIA) approaches, such as SWATH ® -MS, are showing great potential to reliably quantify significant numbers of peptides and proteins in an unbiased manner. These developments have enhanced interest in developing a single DIA method which integrates qualitative and quantitative analysis, eliminating the need of a pre-built library of peptide spectra which are created through data-dependent acquisition (DDA) methods or from public repositories. Here we introduce a new DIA approach, referred to as "SWATH-ID", which was developed to allow peptide identification as well as quantitation. The SWATH-ID method is composed of small Q1 windows, achieving better selectivity and thus significantly improving high-confidence peptide extractions from data files. Furthermore, the SWATH-ID approach transmits precursor ions without fragmentation as well as their fragments within the same SWATH acquisition period. This provides a single scan which includes all precursor ions within the isolation window as well as a record of all of their fragment ions, substantially negating the need for a survey scan. In this way all precursors present in a small Q1 window are associated with their fragment ions, improving the identification specificity and providing a more comprehensive and in-depth view of protein and peptide species in complex samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Thermal conductivity measurements in soil using an instrument based on the cylindrical probe method

    Science.gov (United States)

    Nicolas, J.; André, Ph.; Rivez, JF.; Debbaut, V.

    1993-03-01

    The article discusses the underlying hypothesis, the limits, the range of application, and the practical operation of a versatile thermal conductivity analyzer based on a transient cylindrical probe method. The best expected precision for the conductivity determination appears to be ˜±10%. A compact analyzer, integrating all the apparatus' components in the same unit, has been specifically designed for environmental research in the field. Calibration received special attention regarding thermal conductivity values in the range 0.1-3 W/mK. The analyzer was tested on seven materials, in field conditions, and discrepancies from published conductivity values did not exceed 9%. Several checks were performed in the laboratory to study the influence of experimental conditions, such as the probe insertion technique. The cylindrical probe method appears well suited to powdered materials, but may also be applied to viscous liquids and solid matter. As an application, the cylindrical probe was used to characterize nine soils from the Belgian Lorraine. After soil analysis in the dry state, thermal conductivity of each sample was determined at different moisture contents. The transient cylindrical probe method proved to be quick and easy, whether in situ or on samples in the laboratory. It is a powerful tool which can map a country's soil thermal properties.

  19. An instrument-free method based on visible chemical waves for quantifying the ethanol content in alcoholic beverages.

    Science.gov (United States)

    Somboon, Titikan; Sansuk, Sira

    2018-07-01

    An alternative approach using visible chemical waves for ethanol determination is presented. The method is based on the dynamic change of chemical waves in the Belousov-Zhabotinsky (BZ) reaction by perturbation with ethanol. The observablepropagating waves, generatedina Petri dish, can be recorded by using a smartphone camera. The propagating distances are measured from photographic images and then plotted as a function of time to attain the wave velocity. It is found that wave velocities are inversely proportional to ethanol concentrations. By using this linear relationship, the ethanol content can be efficiently quantified with good intra-day and inter-day precision (vodka samples. Hence, this new method provides an alternative practical strategy for simple quantitative detection of ethanol without the need for instruments. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Stacks of SPS Dipole Magnets

    CERN Multimedia

    1974-01-01

    Stacks of SPS Dipole Magnets ready for installation in the tunnel. The SPS uses a separated function lattice with dipoles for bending and quadrupoles for focusing. The 6.2 m long normal conducting dipoles are of H-type with coils that are bent-up at the ends. There are two types, B1 (total of 360) and B2 (384). Both are for a maximum field of 1.8 Tesla and have the same outer dimensions (450x800 mm2 vxh) but with different gaps (B1: 39x129 mm2, B2: 52x92 mm2) tailored to the beam size. The yoke, made of 1.5 mm thick laminations, consists of an upper and a lower half joined together in the median plane once the coils have been inserted.

  1. California dreaming?[PEM stacks

    Energy Technology Data Exchange (ETDEWEB)

    Crosse, J.

    2002-06-01

    Hyundai's Santa Fe FCEV will be on sale by the end of 2002. Hyundai uses PEM stacks that are manufactured by International Fuel Cells (IFC), a division of United Technologies. Santa Fe is equipped with a 65 kW electric powertrain of Enova systems and Shell's new gasoline reformer called Hydrogen Source. Eugene Jang, Senior Engineer - Fuel Cell and Materials at Hyundai stated that the compressor related losses on IFC system are below 3%. The maximum speed offered by the vehicle is estimated as 123km/hr while the petrol equivalent fuel consumption is quoted between 5.6L/100 km and 4.8L/100 km. Santa Fe is a compact vehicle offering better steering response and a pleasant drive. (author)

  2. Stacked-Bloch-wave electron diffraction simulations using GPU acceleration

    International Nuclear Information System (INIS)

    Pennington, Robert S.; Wang, Feng; Koch, Christoph T.

    2014-01-01

    In this paper, we discuss the advantages for Bloch-wave simulations performed using graphics processing units (GPUs), based on approximating the matrix exponential directly instead of performing a matrix diagonalization. Our direct matrix-exponential algorithm yields a functionally identical electron scattering matrix to that generated with matrix diagonalization. Using the matrix-exponential scaling-and-squaring method with a Padé approximation, direct GPU-based matrix-exponential double-precision calculations are up to 20× faster than CPU-based calculations and up to approximately 70× faster than matrix diagonalization. We compare precision and runtime of scaling and squaring methods with either the Padé approximation or a Taylor expansion. We also discuss the stacked-Bloch-wave method, and show that our stacked-Bloch-wave implementation yields the same electron scattering matrix as traditional Bloch-wave matrix diagonalization. - Highlights: • Bloch-wave and stacked-Bloch-wave calculations can be accelerated with GPUs. • Direct approximation of the matrix exponential can be faster than diagonalization. • GPU-based direct approximation can be ≈70× faster than CPU diagonalization. • Larger matrices benefit more from this approach than smaller ones. • Stacked-Bloch-wave scattering results are functionally identical to diagonalization

  3. The use of instrumental neutron activation analysis method in bio-sorption determination

    International Nuclear Information System (INIS)

    Khamidova, Kh.M.; Mutavalieva, Z.S.; Muchamedshina, N.M.; Mirzagatova, A.A.

    2005-01-01

    Full text: Recently, much attention is paid to the research and development of effective metal remediation methods. In industry, for the removal of metals from the industrial solutions and wastes, the expensive ion-exchange resin method of metal sorption is used today. The microbiological methods are much less expensive, are available and provide its application in natural conditions. The search for molybdenum bio sorbent was performed amongst Actinomyces strains. The 18 of Streptomyces strains were used. The data showed that all investigated strains uptake the molybdenum from the solution in various degrees. The molybdenum determination was performed using neutron activation analysis technique. In a nuclear reactor, the samples were treated with a steady flow of neutrons (5.1·10 13 ) n·cm -2 sec -1 in 20 hours. The samples were stored for 6-7 days before analysis. The Actinomyces biomass uptake capacity was up to 94.5 %. The 8 cultures have the most high uptake capacity that varied from 87.4 to 94.5 %. Streptomyces sp. 39 and Streptomyces sp.32 have the lowest bio-sorption capacity amongst studied strains, which was 46.6% and 40 % respectively, whereas the bio sorption capacity of other cultures varied from 55.8 to 64.1%. The influence of some physical and chemical parameters (culture age, pH, temperature) on molybdenum bio-sorption was studied. Data showed that the change in pH, temperature and cultivation period lead to the increase of bio-sorption capacity

  4. Measurement of stain removal in vitro: a comparison of two instrumental methods.

    Science.gov (United States)

    Lath, D L; Johnson, C; Smith, R N; Brook, A H

    2006-08-01

    The aim of this study was to compare an established spectrophotometrical approach for the measurement of stain removal in vitro with a new digital image analysis system. Eighteen acrylic blocks were stained by cycling them through human saliva (2 min), chlorhexidine (2 min) and tea (1 h), rinsed with deionized water and left to air dry. The absorbance of each block was then measured at 395 nm using a single-beam spectrophotometer. The lightness (L-value) of the stained blocks (after a baseline correction) was measured using digital image analysis. Image acquisition and L-values were obtained using Adobe Photoshop software. The stain removal ability of two whitening toothpastes and deionized water was tested by immersing each stained block in a test slurry (15 g paste/60 ml deionized water) for 1 min, rinsing and finally left to air dry. This cycle was repeated until the blocks had 5 min exposure to the slurry. Absorbance values from spectrophotometry and L-values by image analysis were obtained after each cycle. Fleiss' coefficient of reliability for intra-operator repeatability of the image analysis system and spectrophotometry was 0.999 for both methods which shows excellent reliability. Pearson's correlation coefficients for the two methods (stain build-up) were 0.976. Test products A, B and C gave correlations of 0.962, 0.998 and 0.817 respectively (stain removal), significant at the 0.01 level. The image system is a reliable alternative measurement method validated here against spectrophotometry for stain removal in vitro, and can provide full colour measurement.

  5. [The quality indices of the Quick method using thromboplastin reagents performed manually and instrumentally].

    Science.gov (United States)

    Tarasova, L N; Vladimirova, S G; Savinykh, E Iu; Platonov, G K; Rechkin, O I

    2000-03-01

    The reproduction and results of Quick's method with tissue thromboplastin (Kirov Institute of Hematology and Blood Transfusion--KIHBT) and Excel and Excel S simplastins (Organon Teknika, Netherlands) in the tube and automated versions were compared. Semiautomated coagulometer COAG-A-MATE XM and automated COAG-A-MATE RA-4 of the same firm were used. Three Verifi plasmas (Organon Teknika) with different activities of factors II, VII, IX, and X were used. Tests with thromboplastin manufactured by KIHBT were well reproduced both in the tube and automated modifications (CV Quick's test, which recommends the use of these device-reagent combinations for evaluation of PI.

  6. Lossless compression of AVIRIS data: Comparison of methods and instrument constraints

    Science.gov (United States)

    Roger, R. E.; Arnold, J. F.; Cavenor, M. C.; Richards, J. A.

    1992-01-01

    A family of lossless compression methods, allowing exact image reconstruction, are evaluated for compressing Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) image data. The methods are used on Differential Pulse Code Modulation (DPCM). The compressed data have an entropy of order 6 bits/pixel. A theoretical model indicates that significantly better lossless compression is unlikely to be achieved because of limits caused by the noise in the AVIRIS channels. AVIRIS data differ from data produced by other visible/near-infrared sensors, such as LANDSAT-TM or SPOT, in several ways. Firstly, the data are recorded at a greater resolution (12 bits, though packed into 16-bit words). Secondly, the spectral channels are relatively narrow and provide continuous coverage of the spectrum so that the data in adjacent channels are generally highly correlated. Thirdly, the noise characteristics of the AVIRIS are defined by the channels' Noise Equivalent Radiances (NER's), and these NER's show that, at some wavelengths, the least significant 5 or 6 bits of data are essentially noise.

  7. A direct method for calculating instrument noise levels in side-by-side seismometer evaluations

    Science.gov (United States)

    Holcomb, L. Gary

    1989-01-01

    The subject of determining the inherent system noise levels present in modem broadband closed loop seismic sensors has been an evolving topic ever since closed loop systems became available. Closed loop systems are unique in that the system noise can not be determined via a blocked mass test as in older conventional open loop seismic sensors. Instead, most investigators have resorted to performing measurements on two or more systems operating in close proximity to one another and to analyzing the outputs of these systems with respect to one another to ascertain their relative noise levels.The analysis of side-by-side relative performance is inherently dependent on the accuracy of the mathematical modeling of the test configuration. This report presents a direct approach to extracting the system noise levels of two linear systems with a common coherent input signal. The mathematical solution to the problem is incredibly simple; however the practical application of the method encounters some difficulties. Examples of expected accuracies are presented as derived by simulating real systems performance using computer generated random noise. In addition, examples of the performance of the method when applied to real experimental test data are shown.

  8. Utilizing global data to estimate analytical performance on the Sigma scale: A global comparative analysis of methods, instruments, and manufacturers through external quality assurance and proficiency testing programs.

    Science.gov (United States)

    Westgard, Sten A

    2016-06-01

    To assess the analytical performance of instruments and methods through external quality assessment and proficiency testing data on the Sigma scale. A representative report from five different EQA/PT programs around the world (2 US, 1 Canadian, 1 UK, and 1 Australasian) was accessed. The instrument group standard deviations were used as surrogate estimates of instrument imprecision. Performance specifications from the US CLIA proficiency testing criteria were used to establish a common quality goal. Then Sigma-metrics were calculated to grade the analytical performance. Different methods have different Sigma-metrics for each analyte reviewed. Summary Sigma-metrics estimate the percentage of the chemistry analytes that are expected to perform above Five Sigma, which is where optimized QC design can be implemented. The range of performance varies from 37% to 88%, exhibiting significant differentiation between instruments and manufacturers. Median Sigmas for the different manufacturers in three analytes (albumin, glucose, sodium) showed significant differentiation. Chemistry tests are not commodities. Quality varies significantly from manufacturer to manufacturer, instrument to instrument, and method to method. The Sigma-assessments from multiple EQA/PT programs provide more insight into the performance of methods and instruments than any single program by itself. It is possible to produce a ranking of performance by manufacturer, instrument and individual method. Laboratories seeking optimal instrumentation would do well to consult this data as part of their decision-making process. To confirm that these assessments are stable and reliable, a longer term study should be conducted that examines more results over a longer time period. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. INSTRUMENTS AND METHODS OF INVESTIGATION: Solid-solid thermal contact problems: current understanding

    Science.gov (United States)

    Mesnyankin, Sergei Yu; Vikulov, Aleksei G.; Vikulov, Dmitrii G.

    2009-09-01

    The past 40 years of theoretical and experimental research on contact heat transfer are reviewed. Thermophysical and mechanical processes involved in heat flow propagation through various kinds of solid-solid joints are considered. Analytical and semiempirical expressions are presented, which simulate these processes both under vacuum conditions and in the presence of a heat-conducting medium in gaps. Reasons for the experimentally examined heat flux rectification are explained. Studies on thermal contact under a nonstationary regime are covered, as is the possibility of applying classical heat conduction theory to describing the contact thermal properties. A thermodynamic interpretation of the thermal contact resistance is suggested and basic approaches to the study of contact phenomena are described. The heat conduction in nanosystems is briefly reviewed. Theoretical problems yet to be solved are pointed out and possible solution methods suggested.

  10. From Mars to Greenland: Charting gravity with space and airborne instruments - Fields, tides, methods, results

    Science.gov (United States)

    Colombo, Oscar L. (Editor)

    1992-01-01

    This symposium on space and airborne techniques for measuring gravity fields, and related theory, contains papers on gravity modeling of Mars and Venus at NASA/GSFC, an integrated laser Doppler method for measuring planetary gravity fields, observed temporal variations in the earth's gravity field from 16-year Starlette orbit analysis, high-resolution gravity models combining terrestrial and satellite data, the effect of water vapor corrections for satellite altimeter measurements of the geoid, and laboratory demonstrations of superconducting gravity and inertial sensors for space and airborne gravity measurements. Other papers are on airborne gravity measurements over the Kelvin Seamount; the accuracy of GPS-derived acceleration from moving platform tests; airborne gravimetry, altimetry, and GPS navigation errors; controlling common mode stabilization errors in airborne gravity gradiometry, GPS/INS gravity measurements in space and on a balloon, and Walsh-Fourier series expansion of the earth's gravitational potential.

  11. [Methods of process analysis, instruments of quality management. Successful implementation of quality projects].

    Science.gov (United States)

    Seyfarth-Metzger, I; Liebich, B; Volz, A

    2001-09-15

    Meaningful experience and knowledge--the prerequisite for the successful implementation of quality projects--are described in terms of their practical importance on the basis of the experience gained with quality management in the municipal hospital at München-Schwabing (HMS). Against the background of the process of quality assurance or PDCA (Plan Do Check Act), the approach to the selection of suitable themes (problem selection), the prioritization of projects, the appropriate composition of the project group, the description of the problem, and the organization of the project, are discussed. The authors describe the implementation of methods of process analysis such as flow diagrams and cause-and-effect diagrams. The importance of evaluation is justified, and pragmatic approaches are presented. The importance of project documentation and essential contents are discussed.

  12. Quantitative assessment of probability of failing safely for the safety instrumented system using reliability block diagram method

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Zhao, Shoutang; Hu, Bin

    2015-01-01

    Highlights: • Models of PFS for SIS were established by using the reliability block diagram. • The more accurate calculation of PFS for SIS can be acquired by using SL. • Degraded operation of complex SIS does not affect the availability of SIS. • The safe undetected failure is the largest contribution to the PFS of SIS. - Abstract: The spurious trip of safety instrumented system (SIS) brings great economic losses to production. How to ensure the safety instrumented system is reliable and available has been put on the schedule. But the existing models on spurious trip rate (STR) or probability of failing safely (PFS) are too simplified and not accurate, in-depth studies of availability to obtain more accurate PFS for SIS are required. Based on the analysis of factors that influence the PFS for the SIS, using reliability block diagram method (RBD), the quantitative study of PFS for the SIS is carried out, and gives some application examples. The results show that, the common cause failure will increase the PFS; degraded operation does not affect the availability of the SIS; if the equipment was tested and repaired one by one, the unavailability of the SIS can be ignored; the corresponding occurrence time of independent safe undetected failure should be the system lifecycle (SL) rather than the proof test interval and the independent safe undetected failure is the largest contribution to the PFS for the SIS

  13. Radar Target Recognition Based on Stacked Denoising Sparse Autoencoder

    Directory of Open Access Journals (Sweden)

    Zhao Feixiang

    2017-04-01

    Full Text Available Feature extraction is a key step in radar target recognition. The quality of the extracted features determines the performance of target recognition. However, obtaining the deep nature of the data is difficult using the traditional method. The autoencoder can learn features by making use of data and can obtain feature expressions at different levels of data. To eliminate the influence of noise, the method of radar target recognition based on stacked denoising sparse autoencoder is proposed in this paper. This method can extract features directly and efficiently by setting different hidden layers and numbers of iterations. Experimental results show that the proposed method is superior to the K-nearest neighbor method and the traditional stacked autoencoder.

  14. In-core Instrument Subcritical Verification (INCISV) - Core Design Verification Method - 358

    International Nuclear Information System (INIS)

    Prible, M.C.; Heibel, M.D.; Conner, S.L.; Sebastiani, P.J.; Kistler, D.P.

    2010-01-01

    According to the standard on reload startup physics testing, ANSI/ANS 19.6.1, a plant must verify that the constructed core behaves sufficiently close to the designed core to confirm that the various safety analyses bound the actual behavior of the plant. A large portion of this verification must occur before the reactor operates at power. The INCISV Core Design Verification Method uses the unique characteristics of a Westinghouse Electric Company fixed in-core self powered detector design to perform core design verification after a core reload before power operation. A Vanadium self powered detector that spans the length of the active fuel region is capable of confirming the required core characteristics prior to power ascension; reactivity balance, shutdown margin, temperature coefficient and power distribution. Using a detector element that spans the length of the active fuel region inside the core provides a signal of total integrated flux. Measuring the integrated flux distributions and changes at various rodded conditions and plant temperatures, and comparing them to predicted flux levels, validates all core necessary core design characteristics. INCISV eliminates the dependence on various corrections and assumptions between the ex-core detectors and the core for traditional physics testing programs. This program also eliminates the need for special rod maneuvers which are infrequently performed by plant operators during typical core design verification testing and allows for safer startup activities. (authors)

  15. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 3, Inorganic instrumental methods

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    The methods cover: C in solutions, F (electrode), elements by atomic emission spectrometry, inorganic anions by ion chromatography, Hg in water/solids/sludges, As, Se, Bi, Pb, data calculations for SST (single shell tank?) samples, Sb, Tl, Ag, Pu, O/M ratio, ignition weight loss, pH value, ammonia (N), Cr(VI), alkalinity, U, C sepn. from soil/sediment/sludge, Pu purif., total N, water, C and S, surface Cl/F, leachable Cl/F, outgassing of Ge detector dewars, gas mixing, gas isotopic analysis, XRF of metals/alloys/compounds, H in Zircaloy, H/O in metals, inpurity extraction, reduced/total Fe in glass, free acid in U/Pu solns, density of solns, Kr/Xe isotopes in FFTF cover gas, H by combustion, MS of Li and Cs isotopes, MS of lanthanide isotopes, GC operation, total Na on filters, XRF spectroscopy QC, multichannel analyzer operation, total cyanide in water/solid/sludge, free cyanide in water/leachate, hydrazine conc., ICP-MS, {sup 99}Tc, U conc./isotopes, microprobe analysis of solids, gas analysis, total cyanide, H/N{sub 2}O in air, and pH in soil.

  16. Stacking technology for a space constrained microsystem

    DEFF Research Database (Denmark)

    Heschel, Matthias; Kuhmann, Jochen Friedrich; Bouwstra, Siebe

    1998-01-01

    In this paper we present a stacking technology for an integrated packaging of an intelligent transducer which is formed by a micromachined silicon transducer and an integrated circuit chip. Transducer and circuitry are stacked on top of each other with an intermediate chip in between. The bonding...

  17. Vector Fields and Flows on Differentiable Stacks

    DEFF Research Database (Denmark)

    A. Hepworth, Richard

    2009-01-01

    This paper introduces the notions of vector field and flow on a general differentiable stack. Our main theorem states that the flow of a vector field on a compact proper differentiable stack exists and is unique up to a uniquely determined 2-cell. This extends the usual result on the existence...... of vector fields....

  18. 40 CFR 61.44 - Stack sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.44 Section 61.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Firing § 61.44 Stack sampling. (a) Sources subject to § 61.42(b) shall be continuously sampled, during...

  19. Learning OpenStack networking (Neutron)

    CERN Document Server

    Denton, James

    2014-01-01

    If you are an OpenStack-based cloud operator with experience in OpenStack Compute and nova-network but are new to Neutron networking, then this book is for you. Some networking experience is recommended, and a physical network infrastructure is required to provide connectivity to instances and other network resources configured in the book.

  20. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  1. On the "stacking fault" in copper

    NARCIS (Netherlands)

    Fransens, J.R.; Pleiter, F

    2003-01-01

    The results of a perturbed gamma-gamma angular correlations experiment on In-111 implanted into a properly cut single crystal of copper show that the defect known in the literature as "stacking fault" is not a planar faulted loop but a stacking fault tetrahedron with a size of 10-50 Angstrom.

  2. Proposal of stack Effect technology for predicted future years

    Science.gov (United States)

    Teddy Badai Samodra, FX; Adi Indrawan, Iwan

    2017-12-01

    Recently, stack effect is a general problem solver in providing vertical ventilation for urban environmental issues. However, study on resilient technology of stack effect for future years as predicted by climate trend should be conducted. Therefore, this research proposes a design of new technology on operable and adaptable vertical ventilation to the environmental change. The research method is conducted by comprehensive simulation of Ecotect Analysis, ANSYS Fluent and Matlab. Urban environment of Surabaya, as the research location, is the representative of tropical region. The results showed that the stack effect height and area could be modified instantly adjusting the environmental condition time by time in the future years. With 1.8 m of stack width, the proposed technology could capture 40 m3 of vertical air flow which is useful for physiological cooling and its dimension could be modified depending on the environmental condition. By providing resilient technology, predictable and sustainable ventilation method is offered to anticipate an unpredicted global warming and environmental change.

  3. D.P.M. METHOD - A PERFORMANCE ANALYSIS INSTRUMENT OF A STRATEGIC BUSINESS UNIT

    Directory of Open Access Journals (Sweden)

    Ionescu Florin Tudor

    2012-12-01

    Full Text Available Considering the uncertain economic conditions, the market dynamics, the fundamental changes in the attitudes and aspirations of the consumers along with the strong growth of the political role and interventions in the economy, currently characterizing both Romania and other countries of the world, it can be said that the need for strategic planning was never so acute as now. The strategic planning process is an ongoing organizational activity by which managers can make decisions about their present and future position. A number of analytical portfolio tools exist to aid managers in the formulation of the strategy. The use of these tools within the broader context of the overall strategic planning process allows managers to determine the obstacles and opportunities existing in the company’s environment and to define and pursue appropriate strategies for growth and profitability. The present paper aims to highlight from a theoretical standpoint the D.P.M. method, its strategic consequences, advantages and disadvantages. After conducting this analysis I have found that restricting the business portfolio analysis to the D.P.M. matrix is not a very wise decision. The D.P.M. matrix among with other marketing tools of business portfolio analysis have some advantages and disadvantages and is trying to provide, at a time, a specific diagnosis of a company’s business portfolio. Therefore, the recommendation for the Romanian managers consists in a combined use of a wide range of tools and techniques for business portfolio analysis. This leads to a better understanding of the whole mix of product markets, included in portfolio analysis, the strategic position held by each business within a market, the performance potential of business portfolio and the financial aspects related to the resource allocation process for the businesses within the portfolio. It should also be noted that the tools and techniques specific to business portfolio

  4. Status of MCFC stack technology at IHI

    Energy Technology Data Exchange (ETDEWEB)

    Hosaka, M.; Morita, T.; Matsuyama, T.; Otsubo, M. [Ishikawajima-Harima Heavy Industries Co., Ltd., Tokyo (Japan)

    1996-12-31

    The molten carbonate fuel cell (MCFC) is a promising option for highly efficient power generation possible to enlarge. IHI has been studying parallel flow MCFC stacks with internal manifolds that have a large electrode area of 1m{sup 2}. IHI will make two 250 kW stacks for MW plant, and has begun to make cell components for the plant. To improve the stability of stack, soft corrugated plate used in the separator has been developed, and a way of gathering current from stacks has been studied. The DC output potential of the plant being very high, the design of electric insulation will be very important. A 20 kW short stack test was conducted in 1995 FY to certificate some of the improvements and components of the MW plant. These activities are presented below.

  5. Study of Material Moisture Measurement Method and Instrument by the Combination of Fast Neutron Absorption and γ Absorption

    International Nuclear Information System (INIS)

    Hou Chaoqin; Gong Yalin; Zhang Wei; Shang Qingmin; Li Yanfeng; Gou Qiangyuan; Yin Deyou

    2010-01-01

    To solve the problem of on-line sinter moisture measurement in the iron making plant, we developed material moisture measurement method and instrument by the combination of fast neutron absorption and y-absorption. It overcomes the present existed problems of other moisture meters for the sinter. Compare with microwave moisture meter, the measurement dose not affected by conductance and magnetism of material; to infrared moisture meter, the measurement result dose not influenced by colour and light-reflect performance of material surface, dose not influenced by changes of material kind; to slow neutron scatter moisture meter, the measurement dose not affected by density of material and thickness of hopper wall; to the moisture measurement meter which combined by slow neutron penetrate through and y-absorption, there are definite math model and good linear relation between the measurement values, and the measurement dose not affected by material thickness, changes of material form and component. (authors)

  6. The extended wedge method: atomic force microscope friction calibration for improved tolerance to instrument misalignments, tip offset, and blunt probes.

    Science.gov (United States)

    Khare, H S; Burris, D L

    2013-05-01

    One of the major challenges in understanding and controlling friction is the difficulty in bridging the length and time scales of macroscale contacts and those of the single asperity interactions they comprise. While the atomic force microscope (AFM) offers a unique ability to probe tribological surfaces in a wear-free single-asperity contact, instrument calibration challenges have limited the usefulness of this technique for quantitative nanotribological studies. A number of lateral force calibration techniques have been proposed and used, but none has gained universal acceptance due to practical considerations, configuration limitations, or sensitivities to unknowable error sources. This paper describes a simple extension of the classic wedge method of AFM lateral force calibration which: (1) allows simultaneous calibration and measurement on any substrate, thus eliminating prior tip damage and confounding effects of instrument setup adjustments; (2) is insensitive to adhesion, PSD cross-talk, transducer/piezo-tube axis misalignment, and shear-center offset; (3) is applicable to integrated tips and colloidal probes; and (4) is generally applicable to any reciprocating friction coefficient measurement. The method was applied to AFM measurements of polished carbon (99.999% graphite) and single crystal MoS2 to demonstrate the technique. Carbon and single crystal MoS2 had friction coefficients of μ = 0.20 ± 0.04 and μ = 0.006 ± 0.001, respectively, against an integrated Si probe. Against a glass colloidal sphere, MoS2 had a friction coefficient of μ = 0.005 ± 0.001. Generally, the measurement uncertainties ranged from 10%-20% and were driven by the effect of actual frictional variation on the calibration rather than calibration error itself (i.e., due to misalignment, tip-offset, or probe radius).

  7. A Contribution To The Development And Analysis Of A Combined Current-Voltage Instrument Transformer By Using Modern CAD Methods

    International Nuclear Information System (INIS)

    Chundeva-Blajer, Marija M.

    2004-01-01

    The principle aim and task of the thesis is the analysis and development of 20 kV combined current-voltage instrument transformer (CCVIT) by using modern CAD techniques. CCVIT is a complex electromagnetic system comprising of four windings and two magnetic cores in one insulation housing for simultaneous transformation of high voltages and currents to measurable signal values by standard instruments. The analytical design methods can be applied on simple electromagnetic configurations, which is not the case with the CCVIT. There is mutual electromagnetic influence between the voltage measurement core (VMC) and the current measurement core (CMC). After the analytical CCVIT design had been done, exact determination of its metrological characteristics has been accomplished by using the numerical finite element method implemented in the FEM-3D program package. The FEM-3D calculation is made in 19 cross-sectional layers of the z-axis of the CCVIT three-dimensional domain. By FEM-3D application the three-dimensional CCVIT magnetic field distribution is derived. This is the basis for calculation of the initial metrological characteristics of the CCVIT (VMC is accuracy class 3 and CMC is accuracy class 1). By using the stochastic optimization technique based on genetic algorithm the CCVIT optimal design is achieved. The objective function is the minimum of the metrological parameters (VIM voltage error and CMC current error). There are I I independent input variables during the optimization process by which the optimal project is derived. The optimal project is adapted for realization of a prototype and the optimized project is derived. Full comparative analysis of the metrological and the electromagnetic characteristics of the three projects is accomplished. By application of the program package MATLAB/SIMULINK the CCVIT transient phenomena is analyzed for different regimes in the three design projects. In the Instrument Transformer Factory of EMO A. D.-Ohrid a CCVIT

  8. Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

    Science.gov (United States)

    Allen, W. A.; Richardson, A. J.

    1971-01-01

    Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

  9. Leir beam instrumentation

    CERN Document Server

    Bal, C; Burger, S; Dutriat, C; Gasior, M; Lefèvre, T; Lenardon, F; Odier, P; Raich, U; Soby, L; Tan, J; Tranquille, G; Vuitton, C

    2005-01-01

    The Low Energy Ion Ring (LEIR) is central to the “Ions for LHC” project. Its role is to transform a serie of long low intensity ion pulses from Linac 3, into short high density pulses, which will be further accelerated in the PS and SPS rings, before injection into LHC. To do so the injected pulses are stacked and phase space cooled using electron cooling, before acceleration to the ejection energy of 72 MEV/u. This note describes different types of instruments which will be installed in the LEIR ring and transfer lines.

  10. Geometric Patterns for Neighboring Bases Near the Stacked State in Nucleic Acid Strands.

    Science.gov (United States)

    Sedova, Ada; Banavali, Nilesh K

    2017-03-14

    Structural variation in base stacking has been analyzed frequently in isolated double helical contexts for nucleic acids, but not as often in nonhelical geometries or in complex biomolecular environments. In this study, conformations of two neighboring bases near their stacked state in any environment are comprehensively characterized for single-strand dinucleotide (SSD) nucleic acid crystal structure conformations. An ensemble clustering method is used to identify a reduced set of representative stacking geometries based on pairwise distances between select atoms in consecutive bases, with multiple separable conformational clusters obtained for categories divided by nucleic acid type (DNA/RNA), SSD sequence, stacking face orientation, and the presence or absence of a protein environment. For both DNA and RNA, SSD conformations are observed that are either close to the A-form, or close to the B-form, or intermediate between the two forms, or further away from either form, illustrating the local structural heterogeneity near the stacked state. Among this large variety of distinct conformations, several common stacking patterns are observed between DNA and RNA, and between nucleic acids in isolation or in complex with proteins, suggesting that these might be stable stacking orientations. Noncanonical face/face orientations of the two bases are also observed for neighboring bases in the same strand, but their frequency is much lower, with multiple SSD sequences across categories showing no occurrences of such unusual stacked conformations. The resulting reduced set of stacking geometries is directly useful for stacking-energy comparisons between empirical force fields, prediction of plausible localized variations in single-strand structures near their canonical states, and identification of analogous stacking patterns in newly solved nucleic acid containing structures.

  11. The impact of stack geometry and mean pressure on cold end temperature of stack in thermoacoustic refrigeration systems

    Science.gov (United States)

    Wantha, Channarong

    2018-02-01

    This paper reports on the experimental and simulation studies of the influence of stack geometries and different mean pressures on the cold end temperature of the stack in the thermoacoustic refrigeration system. The stack geometry was tested, including spiral stack, circular pore stack and pin array stack. The results of this study show that the mean pressure of the gas in the system has a significant impact on the cold end temperature of the stack. The mean pressure of the gas in the system corresponds to thermal penetration depth, which results in a better cold end temperature of the stack. The results also show that the cold end temperature of the pin array stack decreases more than that of the spiral stack and circular pore stack geometry by approximately 63% and 70%, respectively. In addition, the thermal area and viscous area of the stack are analyzed to explain the results of such temperatures of thermoacoustic stacks.

  12. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  13. Method for the Analysis of Temporal Change of Physical Structure in the Instrumentation and Control Life-Cycle

    International Nuclear Information System (INIS)

    Goering, Markus; Fay, Alexander

    2013-01-01

    The design of computer-based instrumentation and control (I and C) systems is determined by the allocation of I and C functions to I and C systems and components. Due to the characteristics of computer-based technology, component failures can negatively affect several I and C functions, so that the reliability proof of the I and C systems requires the accomplishment of I and C system design analyses throughout the I and C life-cycle. On one hand, this paper proposes the restructuring of the sequential IEC 61513 I and C life-cycle according to the V-model, so as to adequately integrate the concept of verification and validation. On the other hand, based on a meta model for the modeling of I and C systems, this paper introduces a method for the modeling and analysis of the effects with respect to the superposition of failure combinations and event sequences on the I and C system design, i.e. the temporal change of physical structure is analyzed. In the first step, the method is concerned with the modeling of the I and C systems. In the second step, the method considers the analysis of temporal change of physical structure, which integrates the concepts of the diversity and defense-in-depth analysis, fault tree analysis, event tree analysis, and failure mode and effects analysis

  14. Validation of an analytical method for determining halothane in urine as an instrument for evaluating occupational exposure

    International Nuclear Information System (INIS)

    Gonzalez Chamorro, Rita Maria; Jaime Novas, Arelis; Diaz Padron, Heliodora

    2010-01-01

    The occupational exposure to harmful substances may impose the apparition of determined significative changes in the normal physiology of the organism when the adequate security measures are not taken in time in a working place where the risk may be present. Among the chemical risks that may affect the workers' health are the inhalable anesthetic agents. With the objective to take the first steps for the introduction of an epidemiological surveillance system to this personnel, an analytical method for determining this anesthetic in urine was validated with the instrumental conditions created in our laboratory. To carry out this validation the following parameters were taken into account: specificity, lineament, precision, accuracy, detection limit and quantification limit, and the uncertainty of the method was calculated. In the validation procedure it was found that the technique is specific and precise, the detection limit was of 0,118 μg/L, and of the quantification limit of 0,354 μg/L. The global uncertainty was of 0,243, and the expanded of 0,486. The validated method, together with the posterior introduction of the biological exposure limits, will serve as an auxiliary means of diagnosis which will allow us a periodical control of the personnel exposure

  15. From the components to the stack. Developing and designing 5kW HT-PEFC stacks; Von der Komponente zum Stack. Entwicklung und Auslegung von HT-PEFC-Stacks der 5 kW-Klasse

    Energy Technology Data Exchange (ETDEWEB)

    Bendzulla, Anne

    2010-12-22

    The aim of the present project is to develop a stack design for a 5-kW HTPEFC system. First, the state of the art of potential materials and process designs will be discussed for each component. Then, using this as a basis, three potential stack designs with typical attributes will be developed and assessed in terms of practicality with the aid of a specially derived evaluation method. Two stack designs classified as promising will be discussed in detail, constructed and then characterized using short stack tests. Comparing the stack designs reveals that both designs are fundamentally suitable for application in a HT-PEFC system with on-board supply. However, some of the performance data differ significantly for the two stack designs. The preferred stack design for application in a HT-PEFC system is characterized by robust operating behaviour and reproducible high-level performance data. Moreover, in compact constructions (120 W/l at 60 W/kg), the stack design allows flexible cooling with thermal oil or air, which can be adapted to suit specific applications. Furthermore, a defined temperature gradient can be set during operation, allowing the CO tolerance to be increased by up to 10 mV. The short stack design developed within the scope of the present work therefore represents an ideal basis for developing a 5-kW HT-PEFC system. Topics for further research activities include improving the performance by reducing weight and/or volume, as well as optimizing the heat management. The results achieved within the framework of this work clearly show that HTPEFC stacks have the potential to play a decisive role in increasing efficiency in the future, particularly when combined with an on-board supply system. (orig.) [German] Ziel der vorliegenden Arbeit ist die Entwicklung eines Stackkonzeptes fuer ein 5 kW-HT-PEFC System. Dazu wird zunaechst fuer jede Komponente der Stand der Technik moeglicher Materialien und Prozesskonzepte diskutiert. Darauf aufbauend werden drei

  16. Seismic fragility of ventilation stack of nuclear power plant

    International Nuclear Information System (INIS)

    Nefedov, S.S.; Yugai, T.Z.; Kalinkin, I.V.; Vizir, P.L.

    2003-01-01

    Fragility study of safety related elements is necessary step in seismic PSA of nuclear power plant (NPP). In present work fragility was analyzed after the example of the ventilation stack of NPP. Ventilation stack, considered in present work, is a separately erected construction with height of 100 m made of cast-in-place reinforced concrete. In accordance with IAEA terminology fragility of element is defined as conditional probability of its failure at given level of seismic loading. Failure of a ventilation stack was considered as development of the plastic hinge in some section of a shaft. Seismic ground acceleration a, which corresponds to failure, could be defined as limit seismic acceleration of ventilation stack [a]. Limit seismic acceleration [a] was considered as random value. Sources of its variation are connected with stochastic nature of factors determining it (properties of construction materials, soils etc.), and also with uncertainties of existing analytical techniques. Random value [a] was assumed to be distributed lognormally. Median m[a] and logarithmically standard deviation β of this distribution were defined by 'scaling method' developed by R.P. Kennedy et al. Using this values fragility curves were plotted for different levels of confidence probability. (author)

  17. Development and Applications of a Stage Stacking Procedure

    Science.gov (United States)

    Kulkarni, Sameer; Celestina, Mark L.; Adamczyk, John J.

    2012-01-01

    The preliminary design of multistage axial compressors in gas turbine engines is typically accomplished with mean-line methods. These methods, which rely on empirical correlations, estimate compressor performance well near the design point, but may become less reliable off-design. For land-based applications of gas turbine engines, off-design performance estimates are becoming increasingly important, as turbine plant operators desire peaking or load-following capabilities and hot-day operability. The current work develops a one-dimensional stage stacking procedure, including a newly defined blockage term, which is used to estimate the off-design performance and operability range of a 13-stage axial compressor used in a power generating gas turbine engine. The new blockage term is defined to give mathematical closure on static pressure, and values of blockage are shown to collapse to curves as a function of stage inlet flow coefficient and corrected shaft speed. In addition to these blockage curves, the stage stacking procedure utilizes stage characteristics of ideal work coefficient and adiabatic efficiency. These curves are constructed using flow information extracted from computational fluid dynamics (CFD) simulations of groups of stages within the compressor. Performance estimates resulting from the stage stacking procedure are shown to match the results of CFD simulations of the entire compressor to within 1.6% in overall total pressure ratio and within 0.3 points in overall adiabatic efficiency. Utility of the stage stacking procedure is demonstrated by estimation of the minimum corrected speed which allows stable operation of the compressor. Further utility of the stage stacking procedure is demonstrated with a bleed sensitivity study, which estimates a bleed schedule to expand the compressors operating range.

  18. Application of k0-based internal mono standard instrumental neutron activation analysis method method for composition analysis of stainless steel clad sample

    International Nuclear Information System (INIS)

    Acharya, R.; Nair, A.G.C.; Reddy, A.V.R.; Goswami, A.

    2004-01-01

    The k 0 -based internal mono standard instrumental neutron activation analysis (INAA) method was used for the composition analysis of some irregular shape stainless steel (SS) samples of type SS 316M, which is used as fuel cladding in Indian fast breeder test reactor (FBTR). The method utilizes in situ relative detection efficiency using γ-rays of the activation products present in the sample for overcoming γ-ray self-attenuation. Samples were neutron activated using the thermal column as well as the core position of the reactor and the assay of radioactivity was carried out by high-resolution gamma ray spectrometry. The elements determined were Fe, Cr, Ni, Mo, Mn, Co, Cu, As and W. Since all the major elements (Fe, Cr, Ni, Mo and Mn) were amenable to NAA, the relative elemental concentrations with respect to Fe, obtained by this method, were converted to their absolute values by mass balance. The results were compared with specified compositions and found to be satisfactory. In order to validate these results obtained by the standard-less approach, sub samples of SS 316M in solution forms were analyzed by prevalent relative and k 0 methods of INAA, and results were found to be in good agreement. The accuracy of the internal mono standard INAA method has been evaluated by analyzing an alloy steel certified reference material, CRM 225/1 of British Chemical Standards (BCS)

  19. Nuclear reactor instrumentation method

    International Nuclear Information System (INIS)

    Handa, Hiroyuki; Hayashi, Katsumi; Nemesawa, Shigeki; Nemoto, Yuji; Ohashi, Masahisa.

    1993-01-01

    The present invention can appropriately monitor the state of a reactor core in an FBR type reactor which has a system of storing spent fuel assemblies in a reactor container while reducing the weight and making the structure compact in the reactor. That is, a fuel assembly having a shield lacking portion in upper axial shields is disposed. The shield lacking portion defines neutrons' leaking path from the reactor core. The leakage of neutrons from the path is detected by a neutron monitor disposed just above the fuel assembly. With such a constitution, influence of neutrons from stored spent fuel assemblies disposed to the out side of the radial shields can be reduced by a shielding effect of the existent radial shields around the reactor core. Further, if a shield lacking portion is locally disposed in the region of the upper axial shields just below the neutron monitor, neutrons from the reactor core can be monitored while suppressing excessive neutron leakage. As a result, it is unnecessary to dispose shields on the outer side of the spent fuel assembly disposed in the reactor core. (I.S.)

  20. Instrumental methods in electrochemistry

    CERN Document Server

    Pletcher, D; Peat, R

    2010-01-01

    Using 372 references and 211 illustrations, this book underlines the fundamentals of electrochemistry essential to the understanding of laboratory experiments. It treats not only the fundamental concepts of electrode reactions, but also covers the methodology and practical application of the many versatile electrochemical techniques available.Underlines the fundamentals of electrochemistry essential to the understanding of laboratory experimentsTreats the fundamental concepts of electrode reactionsCovers the methodology and practical application of the many ve

  1. Development of method for experimental determination of wheel–rail contact forces and contact point position by using instrumented wheelset

    International Nuclear Information System (INIS)

    Bižić, Milan B; Petrović, Dragan Z; Tomić, Miloš C; Djinović, Zoran V

    2017-01-01

    This paper presents the development of a unique method for experimental determination of wheel–rail contact forces and contact point position by using the instrumented wheelset (IWS). Solutions of key problems in the development of IWS are proposed, such as the determination of optimal locations, layout, number and way of connecting strain gauges as well as the development of an inverse identification algorithm (IIA). The base for the solution of these problems is the wheel model and results of FEM calculations, while IIA is based on the method of blind source separation using independent component analysis. In the first phase, the developed method was tested on a wheel model and a high accuracy was obtained (deviations of parameters obtained with IIA and really applied parameters in the model are less than 2%). In the second phase, experimental tests on the real object or IWS were carried out. The signal-to-noise ratio was identified as the main influential parameter on the measurement accuracy. Тhе obtained results have shown that the developed method enables measurement of vertical and lateral wheel–rail contact forces Q and Y and their ratio Y / Q with estimated errors of less than 10%, while the estimated measurement error of contact point position is less than 15%. At flange contact and higher values of ratio Y / Q or Y force, the measurement errors are reduced, which is extremely important for the reliability and quality of experimental tests of safety against derailment of railway vehicles according to the standards UIC 518 and EN 14363. The obtained results have shown that the proposed method can be successfully applied in solving the problem of high accuracy measurement of wheel–rail contact forces and contact point position using IWS. (paper)

  2. Characterisation and Modelling of a High Temperature PEM Fuel Cell Stack using Electrochemical Impedance Spectroscopy

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Jespersen, Jesper Lebæk; Schaltz, Erik

    2009-01-01

    temperature PEM (HTPEM) fuel cell stack. A Labview virtual instrument has been developed to perform the signal generation and data acquisition which is needed to perform EIS. The typical output of an EIS measurement on a fuel cell, is a Nyquist plot, which shows the imaginary and real part of the impedance...

  3. In-Core-Instrumentation Methods for 3-Dimensional Distribution Information of Reactor Core Temperatures and Melt-down

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yeong Cheol [KHNP, Daejeon (Korea, Republic of); Eun, Myoung; Kim, Sung Jun [Woojin Inc., Hwaseong (Korea, Republic of)

    2014-08-15

    temperature profile of the core rather than guesses and assumptions. Furthermore, this goal needs to be achieved economically and with minimal changes to current design of reactor and its instrumentation that has been proven and well established through many years of operation. In this paper, methods for a new ICI system to provide three-dimensional view of the reactor core temperatures and melt-down are introduced.

  4. Autoclave sterilization of instruments used on women with cervical neoplasia is an effective method of eradicating residual human papillomavirus DNA: a polymerase chain reaction-based evaluation.

    Science.gov (United States)

    Estes, Jacob M; Kirby, Tyler O; Huh, Warner K

    2007-01-01

    To determine whether autoclave sterilization eradicates human papillomavirus (HPV) DNA on specula and instruments used to treat women with cervical neoplasia. Specula and instruments used in two referral colposcopy clinics were evaluated to determine the PGMY9/11 primer system's ability to amplify residual HPV DNA. Each speculum and instrument was sampled with a Dacron swab and stored in PreservCyt solution (Cytyc Corporation, Marlborough, MA) at 4 degrees C. DNA amplification was performed under standard conditions with appropriate controls followed by HPV typing using the reverse line blot test (Roche Molecular Systems, Alameda, CA). Once validated, the same polymerase chain reaction method was used on autoclave-sterilized specula and biopsy instruments and heated glass bead- and Cidex bath (Johnson & Johnson, New Brunswick, NJ)-sterilized instruments. All results, with appropriate positive and negative controls, were confirmed in triplicate. A total of 140 instruments (70 used and 70 autoclaved) were sampled for residual HPV DNA. Five samples in the contaminated specula arm were excluded from analysis secondary to insufficient sampling. Of the remaining samples, 52.3% (34/65) of contaminated instruments-both specula and biopsy instruments-had detectable HPV DNA. Fifty-five percent of contaminated biopsy instruments (11/20) were positive and 51.1% of contaminated specula (23/45) were positive. All 70 autoclaved samples (50 specula and 20 biopsy instruments) were negative for residual HPV DNA or beta-globin. One instrument in the glass bead and Cidex group that was presumed sterile was positive for HPV 16 DNA. The PGMY9/11 primer system is an effective method to detect residual HPV DNA. Autoclave sterilization appears to eradicate HPV DNA to levels undetectable with this sensitive assay, whereas heated glass beads followed by Cidex bath appears to be inadequate methods. These results suggest that autoclave sterilization is effective when using nondisposable

  5. Design of measuring instrument with whole direct method for bed shear stress under two-dimensional water-flow co-action

    Science.gov (United States)

    Huang, Hai-long; Zuo, Qi-hua; Zhou, Yi-ren; Shen, Yu-sheng; Li, Lan-xi

    2016-12-01

    The present study aims at the design and making of measuring instrument of whole direct method for bed shear stress under two-dimensional water-flow co-action. The instrument combines the traditional strain gauge with a precise pressure gauge, and adopts the method directly measuring the difference between the lateral hydrodynamic pressure and different head pressures on both sides of the force plate. As a result, such an instrument solves a technical puzzle of the past strain gauge, i.e. the difficulty to set apart shear stress and lateral force. Static force test and sink test both prove that the instrument is precise, stable and applicable to the measurement of rough beds with different shear stresses.

  6. Density of oxidation-induced stacking faults in damaged silicon

    NARCIS (Netherlands)

    Kuper, F.G.; Hosson, J.Th.M. De; Verwey, J.F.

    1986-01-01

    A model for the relation between density and length of oxidation-induced stacking faults on damaged silicon surfaces is proposed, based on interactions of stacking faults with dislocations and neighboring stacking faults. The model agrees with experiments.

  7. Comparison of source moment tensor recovered by diffraction stacking migration and source time reversal imaging

    Science.gov (United States)

    Zhang, Q.; Zhang, W.

    2017-12-01

    Diffraction stacking migration is an automatic location methods and widely used in microseismic monitoring of the hydraulic fracturing. It utilizes the stacking of thousands waveform to enhance signal-to-noise ratio of weak events. For surface monitoring, the diffraction stacking method is suffered from polarity reverse among receivers due to radiation pattern of moment source. Joint determination of location and source mechanism has been proposed to overcome the polarity problem but needs significantly increased computational calculations. As an effective method to recover source moment tensor, time reversal imaging based on wave equation can locate microseismic event by using interferometry on the image to extract source position. However, the time reversal imaging is very time consuming compared to the diffraction stacking location because of wave-equation simulation.In this study, we compare the image from diffraction stacking and time reversal imaging to check if the diffraction stacking can obtain similar moment tensor as time reversal imaging. We found that image produced by taking the largest imaging value at each point along time axis does not exhibit the radiation pattern, while with the same level of calculation efficiency, the image produced for each trial origin time can generate radiation pattern similar to time reversal imaging procedure. Thus it is potential to locate the source position by the diffraction stacking method for general moment tensor sources.

  8. Assessment for potential radionuclide emissions from stacks and diffuse and fugitive sources on the Hanford Site

    International Nuclear Information System (INIS)

    Davis, W.E.; Schmidt, J.W.; Gleckler, B.P.; Rhoads, K.

    1995-06-01

    By using the six EPA-approved methods, instead of only the original back calculation method for assessing the 84 WHC registered stacks, the number of stacks requiring continuous monitoring was reduced from 32 to 19 stacks. The intercomparison between results showed that no correlation existed between back calculations and release fractions. Also the NDA, upstream air samples, and powder release fraction method results were at least three orders of magnitude lower then the back calculations results. The most surprising results of the assessment came from NDA. NDA was found to be an easy method for assessing potential emissions. For the nine stacks assessed by NDA, all nine of the stacks would have required continuous monitoring when assessed by back calculations. However, when NDA was applied all stacks had potential emissions that would cause an EDE below the > 0.1 mrem/y standard. Apparent DFs for the HEPA filter systems were calculated for eight nondesignated stacks with emissions above the detection limit. These apparent DFs ranged from 0.5 to 250. The EDE dose to the MEI was calculated to be 0.028 mrem/y for diffuse and fugitive emissions from the Hanford Sited. This is well below the > 0.1 mrem/y standard

  9. Remote Sensing Image Classification Based on Stacked Denoising Autoencoder

    Directory of Open Access Journals (Sweden)

    Peng Liang

    2017-12-01

    Full Text Available Focused on the issue that conventional remote sensing image classification methods have run into the bottlenecks in accuracy, a new remote sensing image classification method inspired by deep learning is proposed, which is based on Stacked Denoising Autoencoder. First, the deep network model is built through the stacked layers of Denoising Autoencoder. Then, with noised input, the unsupervised Greedy layer-wise training algorithm is used to train each layer in turn for more robust expressing, characteristics are obtained in supervised learning by Back Propagation (BP neural network, and the whole network is optimized by error back propagation. Finally, Gaofen-1 satellite (GF-1 remote sensing data are used for evaluation, and the total accuracy and kappa accuracy reach 95.7% and 0.955, respectively, which are higher than that of the Support Vector Machine and Back Propagation neural network. The experiment results show that the proposed method can effectively improve the accuracy of remote sensing image classification.

  10. Black Hole Spectroscopy with Coherent Mode Stacking.

    Science.gov (United States)

    Yang, Huan; Yagi, Kent; Blackman, Jonathan; Lehner, Luis; Paschalidis, Vasileios; Pretorius, Frans; Yunes, Nicolás

    2017-04-21

    The measurement of multiple ringdown modes in gravitational waves from binary black hole mergers will allow for testing the fundamental properties of black holes in general relativity and to constrain modified theories of gravity. To enhance the ability of Advanced LIGO/Virgo to perform such tasks, we propose a coherent mode stacking method to search for a chosen target mode within a collection of multiple merger events. We first rescale each signal so that the target mode in each of them has the same frequency and then sum the waveforms constructively. A crucial element to realize this coherent superposition is to make use of a priori information extracted from the inspiral-merger phase of each event. To illustrate the method, we perform a study with simulated events targeting the ℓ=m=3 ringdown mode of the remnant black holes. We show that this method can significantly boost the signal-to-noise ratio of the collective target mode compared to that of the single loudest event. Using current estimates of merger rates, we show that it is likely that advanced-era detectors can measure this collective ringdown mode with one year of coincident data gathered at design sensitivity.

  11. Tracking-by-detection of surgical instruments in minimally invasive surgery via the convolutional neural network deep learning-based method.

    Science.gov (United States)

    Zhao, Zijian; Voros, Sandrine; Weng, Ying; Chang, Faliang; Li, Ruijian

    2017-12-01

    Worldwide propagation of minimally invasive surgeries (MIS) is hindered by their drawback of indirect observation and manipulation, while monitoring of surgical instruments moving in the operated body required by surgeons is a challenging problem. Tracking of surgical instruments by vision-based methods is quite lucrative, due to its flexible implementation via software-based control with no need to modify instruments or surgical workflow. A MIS instrument is conventionally split into a shaft and end-effector portions, while a 2D/3D tracking-by-detection framework is proposed, which performs the shaft tracking followed by the end-effector one. The former portion is described by line features via the RANSAC scheme, while the latter is depicted by special image features based on deep learning through a well-trained convolutional neural network. The method verification in 2D and 3D formulation is performed through the experiments on ex-vivo video sequences, while qualitative validation on in-vivo video sequences is obtained. The proposed method provides robust and accurate tracking, which is confirmed by the experimental results: its 3D performance in ex-vivo video sequences exceeds those of the available state-of -the-art methods. Moreover, the experiments on in-vivo sequences demonstrate that the proposed method can tackle the difficult condition of tracking with unknown camera parameters. Further refinements of the method will refer to the occlusion and multi-instrumental MIS applications.

  12. Accurate Characterization of Winter Precipitation Using In-Situ Instrumentation, CSU-CHILL Radar, and Advanced Scattering Methods

    Science.gov (United States)

    Newman, A. J.; Notaros, B. M.; Bringi, V. N.; Kleinkort, C.; Huang, G. J.; Kennedy, P.; Thurai, M.

    2015-12-01

    We present a novel approach to remote sensing and characterization of winter precipitation and modeling of radar observables through a synergistic use of advanced in-situ instrumentation for microphysical and geometrical measurements of ice and snow particles, image processing methodology to reconstruct complex particle three-dimensional (3D) shapes, computational electromagnetics to analyze realistic precipitation scattering, and state-of-the-art polarimetric radar. Our in-situ measurement site at the Easton Valley View Airport, La Salle, Colorado, shown in the figure, consists of two advanced optical imaging disdrometers within a 2/3-scaled double fence intercomparison reference wind shield, and also includes PLUVIO snow measuring gauge, VAISALA weather station, and collocated NCAR GPS advanced upper-air system sounding system. Our primary radar is the CSU-CHILL radar, with a dual-offset Gregorian antenna featuring very high polarization purity and excellent side-lobe performance in any plane, and the in-situ instrumentation site being very conveniently located at a range of 12.92 km from the radar. A multi-angle snowflake camera (MASC) is used to capture multiple different high-resolution views of an ice particle in free-fall, along with its fall speed. We apply a visual hull geometrical method for reconstruction of 3D shapes of particles based on the images collected by the MASC, and convert these shapes into models for computational electromagnetic scattering analysis, using a higher order method of moments. A two-dimensional video disdrometer (2DVD), collocated with the MASC, provides 2D contours of a hydrometeor, along with the fall speed and other important parameters. We use the fall speed from the MASC and the 2DVD, along with state parameters measured at the Easton site, to estimate the particle mass (Böhm's method), and then the dielectric constant of particles, based on a Maxwell-Garnet formula. By calculation of the "particle-by-particle" scattering

  13. Dynamical stability of slip-stacking particles

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Jeffrey; Zwaska, Robert

    2014-09-01

    We study the stability of particles in slip-stacking configuration, used to nearly double proton beam intensity at Fermilab. We introduce universal area factors to calculate the available phase space area for any set of beam parameters without individual simulation. We find perturbative solutions for stable particle trajectories. We establish Booster beam quality requirements to achieve 97% slip-stacking efficiency. We show that slip-stacking dynamics directly correspond to the driven pendulum and to the system of two standing-wave traps moving with respect to each other.

  14. Comparative Assessment of the Heart's Functioning by Using the Akabane Test and Classical Methods of Instrumental Examination

    Directory of Open Access Journals (Sweden)

    Valery Muzhikov

    2017-06-01

    Full Text Available Acupuncture physicians have studied the application of reflexotherapy to cardiology. However, no one has investigated the connection of ancient Chinese diagnostic methods with modern tools. A total of 102 patients (54 men and 48 women with heart pathology, namely, sick-sinus syndrome, Wolff–Parkinson–White syndrome, and atrioventricular blockade, were studied using the usual instrumental methods (transesophageal electrophysiological study of the heart, echocardiography, after which they underwent Akabane thermopuncture testing as in traditional Chinese medicine. The results of cardio examination from one side of the Akabane test with that from the other side were compared by means of a multiple stepwise regression analysis. We revealed the effects on the characteristic pattern of acupuncture channel lesions inherent in a definite heart pathology, i.e., the most vulnerable acupuncture channel (AC, of such factors as disturbances of the contractile, conductive, or automatic heart functions, and changes in the chambers' size or circulation volume. Сhanges in the indices of the left and the right branches of these channels usually reflect the opposing natures of the changes in these indicators, which should be considered in reflexotherapy. The main value of the Akabane test along with the use of mathematical analysis lies in early, quick, and inexpensive detection of the above-mentioned heart disturbances.

  15. Research on testing instrument and method for correction of the uniformity of image intensifier fluorescence screen brightness

    Science.gov (United States)

    Qiu, YaFeng; Chang, BenKang; Qian, YunSheng; Fu, RongGuo

    2011-09-01

    To test the parameters of image intensifier screen is the precondition for researching and developing the third generation image intensifier. The picture of brightness uniformity of tested fluorescence screen shows bright in middle and dark at edge. It is not so direct to evaluate the performance of fluorescence screen. We analyze the energy and density distribution of the electrons, After correction, the image in computer is very uniform. So the uniformity of fluorescence screen brightness can be judged directly. It also shows the correction method is reasonable and close to ideal image. When the uniformity of image intensifier fluorescence screen brightness is corrected, the testing instrument is developed. In a vacuum environment of better than 1×10-4Pa, area source electron gun emits electrons. Going through the electric field to be accelerated, the high speed electrons bombard the screen and the screen luminize. By using testing equipment such as imaging luminance meter, fast storage photometer, optical power meter, current meter and photosensitive detectors, the screen brightness, the uniformity, light-emitting efficiency and afterglow can be tested respectively. System performance are explained. Testing method is established; Test results are given.

  16. Study on the polarity, solubility, and stacking characteristics of asphaltenes

    KAUST Repository

    Zhang, Long-li

    2014-07-01

    The structure and transformation of fused aromatic ring system in asphaltenes play an important role in the character of asphaltenes, and in step affect the properties of heavy oils. Polarity, solubility and structural characteristics of asphaltenes derived from Tahe atmospheric residue (THAR) and Tuo-826 heavy crude oil (Tuo-826) were analyzed for study of their internal relationship. A fractionation method was used to separate the asphaltenes into four sub-fractions, based on their solubility in the mixed solvent, for the study of different structural and physical-chemical properties, such as polarity, solubility, morphology, stacking characteristics, and mean structural parameters. Transmission electron microscope (TEM) observation can present the intuitive morphology of asphaltene molecules, and shows that the structure of asphaltenes is in local order as well as long range disorder. The analysis results showed that n-heptane asphaltenes of THAR and Tuo-826 had larger dipole moment values, larger fused aromatic ring systems, larger mean number of stacking layers, and less interlayer spacing between stacking layers than the corresponding n-pentane asphaltenes. The sub-fractions that were inclined to precipitate from the mixture of n-heptane and tetrahydrofuran had larger polarity and less solubility. From the first sub-fraction to the fourth sub-fraction, polarity, mean stacking numbers, and average layer size from the TEM images follow a gradual decrease. The structural parameters derived from TEM images could reflect the largest fused aromatic ring system in asphaltene molecule, yet the parameters derived from 1H NMR data reflected the mean message of poly-aromatic ring systems. The structural parameters derived from TEM images were more consistent with the polarity variation of sub-fractions than those derived from 1H NMR data, which indicates that the largest fused aromatic ring system will play a more important role in the stacking characteristics of

  17. Do Stacked Species Distribution Models Reflect Altitudinal Diversity Patterns?

    Science.gov (United States)

    Mateo, Rubén G.; Felicísimo, Ángel M.; Pottier, Julien; Guisan, Antoine; Muñoz, Jesús

    2012-01-01

    The objective of this study was to evaluate the performance of stacked species distribution models in predicting the alpha and gamma species diversity patterns of two important plant clades along elevation in the Andes. We modelled the distribution of the species in the Anthurium genus (53 species) and the Bromeliaceae family (89 species) using six modelling techniques. We combined all of the predictions for the same species in ensemble models based on two different criteria: the average of the rescaled predictions by all techniques and the average of the best techniques. The rescaled predictions were then reclassified into binary predictions (presence/absence). By stacking either the original predictions or binary predictions for both ensemble procedures, we obtained four different species richness models per taxa. The gamma and alpha diversity per elevation band (500 m) was also computed. To evaluate the prediction abilities for the four predictions of species richness and gamma diversity, the models were compared with the real data along an elevation gradient that was independently compiled by specialists. Finally, we also tested whether our richness models performed better than a null model of altitudinal changes of diversity based on the literature. Stacking of the ensemble prediction of the individual species models generated richness models that proved to be well correlated with the observed alpha diversity richness patterns along elevation and with the gamma diversity derived from the literature. Overall, these models tend to overpredict species richness. The use of the ensemble predictions from the species models built with different techniques seems very promising for modelling of species assemblages. Stacking of the binary models reduced the over-prediction, although more research is needed. The randomisation test proved to be a promising method for testing the performance of the stacked models, but other implementations may still be developed. PMID

  18. STACKING FAULT ENERGY IN HIGH MANGANESE ALLOYS

    Directory of Open Access Journals (Sweden)

    Eva Mazancová

    2009-04-01

    Full Text Available Stacking fault energy of high manganese alloys (marked as TWIP and TRIPLEX is an important parameter determining deformation mechanism type realized in above mentioned alloys. Stacking fault energy level can be asserted with a gliding of partial and/or full dislocations, b gliding mechanism and twinning deformation process in connection with increasing of fracture deformation level (deformation elongation and with increasing of simultaneously realized work hardening proces., c gliding mechanism and deformation induced e-martensite formation. In contribution calculated stacking fault energies are presented for various chemical compositions of high manganese alloys. Stacking fault energy dependences on manganese, carbon, iron and alluminium contents are presented. Results are confronted with some accessible papers.The aim of work is to deepen knowledge of presented data. The TWIP and TRIPLEX alloys can be held for promissing new automotive materials.

  19. Stack-Based Typed Assembly Language

    National Research Council Canada - National Science Library

    Morrisett, Greg

    1998-01-01

    .... This paper also formalizes the typing connection between CPS based compilation and stack based compilation and illustrates how STAL can formally model calling conventions by specifying them as formal translations of source function types to STAL types.

  20. Characterization of Piezoelectric Stacks for Space Applications

    Science.gov (United States)

    Sherrit, Stewart; Jones, Christopher; Aldrich, Jack; Blodget, Chad; Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph

    2008-01-01

    Future NASA missions are increasingly seeking to actuate mechanisms to precision levels in the nanometer range and below. Co-fired multilayer piezoelectric stacks offer the required actuation precision that is needed for such mechanisms. To obtain performance statistics and determine reliability for extended use, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and high temperatures and voltages. In order to study the lifetime performance of these stacks, five actuators were driven sinusoidally for up to ten billion cycles. An automated data acquisition system was developed and implemented to monitor each stack's electrical current and voltage waveforms over the life of the test. As part of the monitoring tests, the displacement, impedance, capacitance and leakage current were measured to assess the operation degradation. This paper presents some of the results of this effort.

  1. The stack on software and sovereignty

    CERN Document Server

    Bratton, Benjamin H

    2016-01-01

    A comprehensive political and design theory of planetary-scale computation proposing that The Stack -- an accidental megastructure -- is both a technological apparatus and a model for a new geopolitical architecture.

  2. STACKING ON COMMON REFLECTION SURFACE WITH MULTIPARAMETER TRAVELTIME

    Directory of Open Access Journals (Sweden)

    Montes V. Luis A.

    2006-12-01

    Full Text Available Commonly seismic images are displayed in time domain because the model in depth can be known only in well logs. To produce seismic sections, pre and post stack processing approaches use time or depth velocity models whereas the common reflection method does not, instead it requires a set of parameters established for the first layer. A set of synthetic data of an anticline model, with sources and receivers placed on a flat topography, was used to observe the performance of this method. As result, a better reflector recovering compared against conventional processing sequence was observed.
    The procedure was extended to real data, using a dataset acquired on a zone characterized by mild topography and quiet environment reflectors in the Eastern Colombia planes, observing an enhanced and a better continuity of the reflectors in the CRS stacked section.

  3. Stacking for Cosmic Magnetism with SKA Surveys

    OpenAIRE

    Stil, J. M.; Keller, B. W.

    2015-01-01

    Stacking polarized radio emission in SKA surveys provides statistical information on large samples that is not accessible otherwise due to limitations in sensitivity, source statistics in small fields, and averaging over frequency (including Faraday synthesis). Polarization is a special case because one obvious source of stacking targets is the Stokes I source catalog, possibly in combination with external catalogs, for example an SKA HI survey or a non-radio survey. We point out the signific...

  4. Environmental Modeling Framework using Stacked Gaussian Processes

    OpenAIRE

    Abdelfatah, Kareem; Bao, Junshu; Terejanu, Gabriel

    2016-01-01

    A network of independently trained Gaussian processes (StackedGP) is introduced to obtain predictions of quantities of interest with quantified uncertainties. The main applications of the StackedGP framework are to integrate different datasets through model composition, enhance predictions of quantities of interest through a cascade of intermediate predictions, and to propagate uncertainties through emulated dynamical systems driven by uncertain forcing variables. By using analytical first an...

  5. Generalized data stacking programming model with applications

    OpenAIRE

    Hala Samir Elhadidy; Rawya Yehia Rizk; Hassen Taher Dorrah

    2016-01-01

    Recent researches have shown that, everywhere in various sciences the systems are following stacked-based stored change behavior when subjected to events or varying environments “on and above” their normal situations. This paper presents a generalized data stack programming (GDSP) model which is developed to describe the system changes under varying environment. These changes which are captured with different ways such as sensor reading are stored in matrices. Extraction algorithm and identif...

  6. Representations of stack triangulations in the plane

    OpenAIRE

    Selig, Thomas

    2013-01-01

    Stack triangulations appear as natural objects when defining an increasing family of triangulations by successive additions of vertices. We consider two different probability distributions for such objects. We represent, or "draw" these random stack triangulations in the plane $\\R^2$ and study the asymptotic properties of these drawings, viewed as random compact metric spaces. We also look at the occupation measure of the vertices, and show that for these two distributions it converges to som...

  7. On the distinction between instrumented indentation technique and x-ray diffraction method in nondestructive or semi-nondestructive surface stress measurement

    International Nuclear Information System (INIS)

    Okano, Shigetaka; Kanamaru, Daisuke; Ihara, Ryohei; Mochizuki, Masahito

    2016-01-01

    In this study, the effect of machined surface layer on stress measurement by means of instrumented indentation technique and X-ray diffraction method was comparatively investigated through the use of three weld specimens of low-carbon austenitic stainless steel with different machined surface layers; as-cutout, mechanically-polished and electrolytically-polished specimens. Tensile and compressive stresses exist respectively in the machined surface layer of as-cutout and mechanically-polished specimens. Meanwhile, no stress and no machined surface layer exist in electrolytically-polished specimen. Tungsten Inert Gas (TIG) bead-on-plate welding was performed under the same welding heat input condition to introduce the residual stress into these three specimens. Against these three specimens, firstly the X-ray diffraction method was applied, then the instrumented indentation technique was applied and finally the stress relief technique was applied to measure the distributions of residual stress after welding. Based on a comparison between these stress measurement results, the instrumented indentation technique was in good agreement with the stress relief technique rather than the X-ray diffraction method, even though both machined surface layer and penetration of indenter had almost the same depths. That is why it can be considered that the instrumented indentation technique measures the residual stress in deeper areas of material surface than penetration depth of indenter. A distinction between the instrumented indentation technique and X-ray diffraction method in surface stress measurement was thus clarified from a viewpoint of measurement depth. (author)

  8. A Time-predictable Stack Cache

    DEFF Research Database (Denmark)

    Abbaspour, Sahar; Brandner, Florian; Schoeberl, Martin

    2013-01-01

    Real-time systems need time-predictable architectures to support static worst-case execution time (WCET) analysis. One architectural feature, the data cache, is hard to analyze when different data areas (e.g., heap allocated and stack allocated data) share the same cache. This sharing leads to le...... of a cache for stack allocated data. Our port of the LLVM C++ compiler supports the management of the stack cache. The combination of stack cache instructions and the hardware implementation of the stack cache is a further step towards timepredictable architectures.......Real-time systems need time-predictable architectures to support static worst-case execution time (WCET) analysis. One architectural feature, the data cache, is hard to analyze when different data areas (e.g., heap allocated and stack allocated data) share the same cache. This sharing leads to less...... precise results of the cache analysis part of the WCET analysis. Splitting the data cache for different data areas enables composable data cache analysis. The WCET analysis tool can analyze the accesses to these different data areas independently. In this paper we present the design and implementation...

  9. Re-fabrication and Instrumentation - resume and outlook

    International Nuclear Information System (INIS)

    Kleeman, Hans-Joerg; Oberlaender, Barbara C.

    2005-01-01

    The special technique ''re-fabrication and instrumentation'' applied at the Institute for Energy Technology (IFE) makes further testing and measuring of irradiated fuel rods in the Halden Boiling Water Reactor (HBWR) possible. Machines, necessary for such operations, were designed and produced at IFE in the years 1991-92. Hot Lab-operations called ''re-fabrication'' include all modifications necessary to load an irradiated fuel rod, commercial or experimental, into the Halden reactor for further testing. ''Instrumentation'' includes all operations necessary to fit instruments into an irradiated fuel rod segment to measure for instance the temperature in the centreline of the fuel stack, pressure increase in the fuel rod and/or changes of the rod length during reactor experiments. The machines used are referred to as: ''Cutting and Grinding Unit'' for machining of the canning; ''Freezing and Drilling Unit'' for drilling of the centreline thermocouple hole in the active fuel stack;''Welding and Drying Unit'' a TIG welding machine for the circumferential welds and the seal welding; and a hydraulic ''Encapsulation Bench''. The ''Welding and Drilling Unit'' includes also a ''He-leak test chamber'' and a ''Hydraulic Press''. In addition, different types of PIE methods are used in quality assurance and documenting of the work done with the fuel rod. For example neutron radiography, visual inspection, dimension measurement, free volume measurements, equipment to measure the flow capability through the fuel stack and different function tests of the measuring devices. This paper will give an overview of the work done so far with this equipment and give information about new equipment which will be installed soon to deal with even more complicated test fuel designs. (Author)

  10. Art, Meet Chemistry; Chemistry, Meet Art: Case Studies, Current Literature, and Instrumental Methods Combined to Create a Hands-On Experience for Nonmajors and Instrumental Analysis Students

    Science.gov (United States)

    Nivens, Delana A.; Padgett, Clifford W.; Chase, Jeffery M.; Verges, Katie J.; Jamieson, Deborah S.

    2010-01-01

    Case studies and current literature are combined with spectroscopic analysis to provide a unique chemistry experience for art history students and to provide a unique inquiry-based laboratory experiment for analytical chemistry students. The XRF analysis method was used to demonstrate to nonscience majors (art history students) a powerful…

  11. Is non-woven fabric a useful method of packaging instruments for operation theatres in resource constrained settings?

    Directory of Open Access Journals (Sweden)

    G S Devadiga

    2015-01-01

    Full Text Available Introduction: Studies have highlighted the advantages and disadvantages of woven and non-woven fabrics. The present study assessed the change in resterilisation proportion after introduction of non-woven fabric for packaging of instruments and to evaluate the cost-effectiveness of non-woven fabrics compared with woven fabrics. Materials and Methods: The present study is a secondary data analysis of resterilisation data collected from November 2009 to August 2013. We calculated the proportions (and their 95% confidence intervals of resterilisation done every month. The proportion over time was compared using a Chi-square test for trend. We used linear regression analysis to adjust for the number of surgeries performed every month. We also compared the cost of woven and non-woven fabrics. Results: Of the total 117,335 surgical packets prepared during the study period, 1900 were resterilised; thus, the overall proportion was 1.62% (95% CI: 1.55% to 1.69%. The resterilisation proportion was 8.95% (95% CI: 7.73% to 10.17% in November 2009 and was 0.38% (95% CI: 0.16% to 0.62% in August 2013 (P < 0.001. After adjusting for the total number of surgeries conducted every month, we found that the number of packets resterilised reduced every month (per month reduction: -1.97, 95% CI: -2.76 to -1.18. The total cost (initial preparation and resterilisation for 100 units of woven fabric is INR 6359.41 per month (confidence limit estimates: 6228.20 to 6430.62 and for non-woven fabric was INR 6208.50 (confidence limit estimate: INR 6194.90 to 6223.35 (P < 0.01. Conclusions: The introduction of non-woven spunbond-meltblown-spunbond fabrics did reduce the proportion of resterilisation of packaged instruments. The decline was sharp and sustained over time, even after accounting for the change in the number of procedures. Furthermore, though the switch from woven to non-woven fabric was cost-effective in our situation, it may not be directly translated to other

  12. Limestone/adipic acid FGD and stack opacity reduction pilot plant tests at Big Rivers

    Energy Technology Data Exchange (ETDEWEB)

    Laslo, D.; Bakke, E.; Chisholm, E.

    1984-01-01

    Big Rivers Electric Corporation (BREC) contracted Peabody Process Systems, Inc. (PPSI) to install a flue gas cleaning (FGC) pilot plant at the BREC R.D. Green Station Unit No. 2 located at Sebree, KY. A six month test program was completed demonstrating technology for: alternatives to using lime as an alkali; methods for improving cake dewatering; identification of the causes of high stack opacity; and methods for the reduction of high stack opacity. This paper presents highlights extracted from the reports submitted by PPSI to BREC on this test program. BREC was primarily interested in reduction of operating costs, if possible, by using an alkali less expensive than lime, and by improving the poor dewatering characteristic inherent in a dolomitic lime system. BREC was also within compliance for particulate emissions and opacity in the duct after the dry electrostatic precipitator, but not in compliance with the stack opacity regulation, and therefore wanted to investigate methods for stack opacity reduction.

  13. Segmentation of RGB-D indoor scenes by stacking random forests and conditional random fields

    DEFF Research Database (Denmark)

    Thøgersen, Mikkel; Guerrero, Sergio Escalera; Gonzàlez, Jordi

    2016-01-01

    on stacked classifiers; the benefits are two fold: on one hand, the system scales well to consider different types of complex features and, on the other hand, the use of stacked classifiers makes the performance of the proposed technique more accurate. The proposed method consists of a random forest using...... a stacked random forest which gives the final predictions. The model is tested on the renown NYU-v2 dataset and the recently available SUNRGBD dataset. The approach shows that simple multimodal features with the power of using multi-class multi-scale stacked sequential learners (MMSSL) can achieve slight...... better performance than state of the art methods on the same dataset. The results show an improvement of 2.3% over the base model by using MMSSL and displays that the method is effective in this problem domain....

  14. Structural color in porous, superhydrophilic, and self-cleaning SiO2/TiO2 Bragg stacks.

    Science.gov (United States)

    Wu, Zhizhong; Lee, Daeyeon; Rubner, Michael F; Cohen, Robert E

    2007-08-01

    Thin-film Bragg stacks exhibiting structural color have been fabricated by a layer-by-layer (LbL) deposition process involving the sequential adsorption of nanoparticles and polymers. High- and low-refractive-index regions of quarter-wave stacks were generated by calcining LbL-assembled multilayers containing TiO(2) and SiO(2) nanoparticles, respectively. The physical attributes of each region were characterized by a recently developed ellipsometric method. The structural color characteristics of the resultant nanoporous Bragg stacks could be precisely tuned in the visible region by varying the number of stacks and the thickness of the high- and low-refractive-index stacks. These Bragg stacks also exhibited potentially useful superhydrophilicity and self-cleaning properties.

  15. From Multi to Single Stack Automata

    Science.gov (United States)

    Atig, Mohamed Faouzi

    We investigate the issue of reducing the verification problem of multi-stack machines to the one for single-stack machines. For instance, elegant (and practically efficient) algorithms for bounded-context switch analysis of multi-pushdown systems have been recently defined based on reductions to the reachability problem of (single-stack) pushdown systems [10,18]. In this paper, we extend this view to both bounded-phase visibly pushdown automata (BVMPA) [16] and ordered multi-pushdown automata (OMPA) [1] by showing that each of their emptiness problem can be reduced to the one for a class of single-stack machines. For these reductions, we introduce effective generalized pushdown automata (EGPA) where operations on stacks are (1) pop the top symbol of the stack, and (2) push a word in some (effectively) given set of words L over the stack alphabet, assuming that L is in some class of languages for which checking whether L intersects regular languages is decidable. We show that the automata-based saturation procedure for computing the set of predecessors in standard pushdown automata can be extended to prove that for EGPA too the set of all predecessors of a regular set of configurations is an effectively constructible regular set. Our reductions from OMPA and BVMPA to EGPA, together with the reachability analysis procedure for EGPA, allow to provide conceptually simple algorithms for checking the emptiness problem for each of these models, and to significantly simplify the proofs for their 2ETIME upper bounds (matching their lower-bounds).

  16. Start-Stop Test Procedures on the PEMFC Stack Level

    DEFF Research Database (Denmark)

    Mitzel, Jens; Nygaard, Frederik; Veltzé, Sune

    The test is addressed to investigate the influence on stack durability of a long stop followed by a restart of a stack. Long stop should be defined as a stop in which the anodic compartment is fully filled by air due to stack leakages. In systems, leakage level of the stack is low and time to fil...

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. Spam comments prediction using stacking with ensemble learning

    Science.gov (United States)

    Mehmood, Arif; On, Byung-Won; Lee, Ingyu; Ashraf, Imran; Choi, Gyu Sang

    2018-01-01

    Illusive comments of product or services are misleading for people in decision making. The current methodologies to predict deceptive comments are concerned for feature designing with single training model. Indigenous features have ability to show some linguistic phenomena but are hard to reveal the latent semantic meaning of the comments. We propose a prediction model on general features of documents using stacking with ensemble learning. Term Frequency/Inverse Document Frequency (TF/IDF) features are inputs to stacking of Random Forest and Gradient Boosted Trees and the outputs of the base learners are encapsulated with decision tree to make final training of the model. The results exhibits that our approach gives the accuracy of 92.19% which outperform the state-of-the-art method.

  19. Calculated stacking-fault energies of elemental metals

    DEFF Research Database (Denmark)

    Rosengaard, N. M.; Skriver, Hans Lomholt

    1993-01-01

    We have performed ab initio calculations of twin, intrinsic, and extrinsic face-centered-cubic stacking faults for all the 3d, 4d, and 5d transition metals by means of a Green's-function technique, based on the linear-muffin-tin-orbitals method within the tight-binding and atomic-sphere approxima......We have performed ab initio calculations of twin, intrinsic, and extrinsic face-centered-cubic stacking faults for all the 3d, 4d, and 5d transition metals by means of a Green's-function technique, based on the linear-muffin-tin-orbitals method within the tight-binding and atomic......-sphere approximations. The results are in excellent agreement with recent layer Korringa-Kohn-Rostoker Green's-function calculations where stacking-fault energies for Ni, Cu, Rh, Pd, Ag, Ir, and Au were found by means of the the so-called force theorem. We find that the self-consistent fault energies for all the metals...... on the local atomic coordination are obeyed to a high degree of accuracy....

  20. EmuStack: An OpenStack-Based DTN Network Emulation Platform (Extended Version

    Directory of Open Access Journals (Sweden)

    Haifeng Li

    2016-01-01

    Full Text Available With the advancement of computing and network virtualization technology, the networking research community shows great interest in network emulation. Compared with network simulation, network emulation can provide more relevant and comprehensive details. In this paper, EmuStack, a large-scale real-time emulation platform for Delay Tolerant Network (DTN, is proposed. EmuStack aims at empowering network emulation to become as simple as network simulation. Based on OpenStack, distributed synchronous emulation modules are developed to enable EmuStack to implement synchronous and dynamic, precise, and real-time network emulation. Meanwhile, the lightweight approach of using Docker container technology and network namespaces allows EmuStack to support a (up to hundreds of nodes large-scale topology with only several physical nodes. In addition, EmuStack integrates the Linux Traffic Control (TC tools with OpenStack for managing and emulating the virtual link characteristics which include variable bandwidth, delay, loss, jitter, reordering, and duplication. Finally, experiences with our initial implementation suggest the ability to run and debug experimental network protocol in real time. EmuStack environment would bring qualitative change in network research works.

  1. Electrochemical Characterization and Degradation Analysis of Large SOFC Stacks by Impedance Spectroscopy

    DEFF Research Database (Denmark)

    Mosbæk, Rasmus Rode; Hjelm, Johan; Barfod, R.

    2013-01-01

    As solid oxide fuel cell (SOFC) technology is moving closer to a commercial break through, lifetime limiting factors, and methods to measure the “state-of-health” of operating cells and stacks are becoming of increasing interest. This requires application of advanced methods for detailed electroc......As solid oxide fuel cell (SOFC) technology is moving closer to a commercial break through, lifetime limiting factors, and methods to measure the “state-of-health” of operating cells and stacks are becoming of increasing interest. This requires application of advanced methods for detailed...... electrochemical characterization during operation. An experimental stack with low ohmic resistance from Topsoe Fuel Cell A/S was characterized in detail using electrochemical impedance spectroscopy (EIS). An investigation of the optimal geometrical placement of the current feeds and voltage probes was carried out...... in order to minimize measurement errors caused by stray impedances. Three different stack geometries were investigated by impedance spectroscopy and the stack geometry with the minimum effect of stray impedances was selected. A 13-cell experimental SOFC stack was tested during 2,500 h of operation...

  2. Enhanced dynamical stability with harmonic slip stacking

    Directory of Open Access Journals (Sweden)

    Jeffrey Eldred

    2016-10-01

    Full Text Available We develop a configuration of radio-frequency (rf cavities to dramatically improve the performance of slip stacking. Slip stacking is an accumulation technique used at Fermilab to nearly double proton intensity by maintaining two beams of different momenta in the same storage ring. The two particle beams are longitudinally focused in the Recycler by two 53 MHz 100 kV rf cavities with a small frequency difference between them. We propose an additional 106 MHz 20 kV rf cavity with a frequency at the double the average of the upper and lower main rf frequencies. We show the harmonic rf cavity cancels out the resonances generated between the two main rf cavities and we derive the relationship between the harmonic rf voltage and the main rf voltage. We find the area factors that can be used to calculate the available phase space area for any set of beam parameters without individual simulation. We establish Booster beam quality requirements to achieve 99% slip stacking efficiency. We measure the longitudinal distribution of the Booster beam and use it to generate a realistic beam model for slip stacking simulation. We demonstrate that the harmonic rf cavity can not only reduce particle loss during slip stacking, but also reduce the final longitudinal emittance.

  3. Non-destructive determination of nitrogen in malting barleys by instrumental photon activation analysis and its comparison with the Dumas method

    Czech Academy of Sciences Publication Activity Database

    Krausová, Ivana; Mizera, Jiří; Dostálek, P.; Řanda, Zdeněk

    2018-01-01

    Roč. 124, č. 1 (2018), s. 4-8 ISSN 0046-9750 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : nitrogen * instrumental photon activation analysis * Dumas method * malting barley Subject RIV: GM - Food Processing OBOR OECD: Food and beverages Impact factor: 0.859, year: 2016

  4. Progress of MCFC stack technology at Toshiba

    Energy Technology Data Exchange (ETDEWEB)

    Hori, M.; Hayashi, T.; Shimizu, Y. [Toshiba Corp., Tokyo (Japan)

    1996-12-31

    Toshiba is working on the development of MCFC stack technology; improvement of cell characteristics, and establishment of separator technology. For the cell technology, Toshiba has concentrated on both the restraints of NiO cathode dissolution and electrolyte loss from cells, which are the critical issues to extend cell life in MCFC, and great progress has been made. On the other hand, recognizing that the separator is one of key elements in accomplishing reliable and cost-competitive MCFC stacks, Toshiba has been accelerating the technology establishment and verification of an advanced type separator. A sub-scale stack with such a separator was provided for an electric generating test, and has been operated for more than 10,000 hours. This paper presents several topics obtained through the technical activities in the MCFC field at Toshiba.

  5. Intercomparison and intercalibration of passive/active radon and active radon progeny instruments and methods in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng W.

    1993-06-01

    An intercomparison and intercalibration exercise for radon and radon progeny measurements made with active and passive instruments was held at EML from October 22--30,1992. Twenty-five participants submitted 96 passive integrating devices, eight active devices for radon, and seven integrating devices for potential alpha energy concentration (PAEC). In addition, 40 grab samples for radon progeny analysis were taken by five groups that participated in person during the intercomparison. The results reported to EML indicate that the majority of the participants (70%) obtained mean results within 10% of the EML reference value. Although the instruments used in this exercise are based on different principles of collection and detection, they all appear reliable. However, in some instances there seemed to be some minor problems with quality control and calibration bias. Also, the large counting errors for the PAEC experienced by some of the participants can be minimized by using higher sampling air flow rates without sacrificing instrument portability

  6. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  7. Multibands tunneling in AAA-stacked trilayer graphene

    Science.gov (United States)

    Redouani, Ilham; Jellal, Ahmed; Bahaoui, Abdelhadi; Bahlouli, Hocine

    2018-04-01

    We study the electronic transport through np and npn junctions for AAA-stacked trilayer graphene. Two kinds of gates are considered where the first is a single gate and the second is a double gate. After obtaining the solutions for the energy spectrum, we use the transfer matrix method to determine the three transmission probabilities for each individual cone τ = 0 , ± 1 . We show that the quasiparticles in AAA-stacked trilayer graphene are not only chiral but also labeled by an additional cone index τ. The obtained bands are composed of three Dirac cones that depend on the chirality indexes. We show that there is perfect transmission for normal or near normal incidence, which is a manifestation of the Klein tunneling effect. We analyze also the corresponding total conductance, which is defined as the sum of the conductance channels in each individual cone. Our results are numerically discussed and compared with those obtained for ABA- and ABC-stacked trilayer graphene.

  8. Using mixed methods to select optimal mode of administration for a patient-reported outcome instrument for people with pressure ulcers.

    Science.gov (United States)

    Rutherford, Claudia; Nixon, Jane; Brown, Julia M; Lamping, Donna L; Cano, Stefan J

    2014-02-12

    When developing new measuring instruments or deciding upon one for research, consideration of the 'best' method of administration for the target population should be made. Current evidence is inconsistent in differentiating superiority of any one method in terms of quantity and quality of response. We trialed a novel mixed methods approach in early scale development to determine the best administration method for a new patient-reported outcome instrument for people with pressure ulcers (the PU-QOL). Cognitive interviews were undertaken with 35 people with pressure ulcers to determine appropriateness of a self-completed version of the PU-QOL instrument. Quantitative analysis, including Rasch analysis, was carried out on PU-QOL data from 70 patients with pressure ulcers, randomised to self-completed or interview-administered groups, to examine data quality and differential item functioning (DIF). Cognitive interviews identified issues with PU-QOL self-completion. Quantitative analysis supported these findings with a large proportion of self-completed PU-QOLs returned with missing data. DIF analysis indicated administration methods did not impact the way patients from community care settings responded, supporting the equivalence of both administration versions. Obtaining the best possible health outcomes data requires use of appropriate methods to ensure high quality data with minimal bias. Mixed methods, with the inclusion of Rasch, provided valuable evidence to support selection of the 'best' administration method for people with PUs during early PRO instrument development. We consider our approach to be generic and widely applicable to other elderly or chronically ill populations or suitable for use in limited samples where recruitment to large field tests is often difficult.

  9. Protein standardization III: Method optimization basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry.

    Science.gov (United States)

    Blirup-Jensen, S

    2001-11-01

    Quantitative protein determinations in routine laboratories are today most often carried out using automated instruments. However, slight variations in the assay principle, in the programming of the instrument or in the reagents may lead to different results. This has led to the prerequisite of method optimization and standardization. The basic principles of turbidimetry and nephelometry are discussed. The different reading principles are illustrated and investigated. Various problems are identified and a suggestion is made for an integrated, fast and convenient test system for the determination of a number of different proteins on the same instrument. An optimized test system for turbidimetry and nephelometry should comprise high-quality antibodies, calibrators, controls, and buffers and a protocol with detailed parameter settings in order to program the instrument correctly. A good user program takes full advantage of the optimal reading principles for the different instruments. This implies--for all suitable instruments--sample preincubation followed by real sample blanking, which automatically corrects for initial turbidity in the sample. Likewise it is recommended to measure the reagent blank, which represents any turbidity caused by the antibody itself. By correcting all signals with these two blank values the best possible signal is obtained for the specific analyte. An optimized test system should preferably offer a wide measuring range combined with a wide security range, which for the user means few re-runs and maximum security against antigen excess. A non-linear calibration curve based on six standards is obtained using a suitable mathematical fitting model, which normally is part of the instrument software.

  10. Design Handbook for a Stack Foundation

    OpenAIRE

    Tuominen, Vilma

    2011-01-01

    This thesis was made for Citec Engineering Oy Ab as a handbook and as a design tool for concrete structure designers. Handbook is about the Wärtsilä Power Plant stack structure, which is a base for about 40 meters high stack pipe. The purpose is to make a calculation base to support the design work, which helps the designer to check the right dimensions of the structure. Thesis is about to be for the concrete designers and also other designers and authorities. As an example I have used an...

  11. Simple model of stacking-fault energies

    DEFF Research Database (Denmark)

    Stokbro, Kurt; Jacobsen, Lærke Wedel

    1993-01-01

    A simple model for the energetics of stacking faults in fcc metals is constructed. The model contains third-nearest-neighbor pairwise interactions and a term involving the fourth moment of the electronic density of states. The model is in excellent agreement with recently published local-density ......A simple model for the energetics of stacking faults in fcc metals is constructed. The model contains third-nearest-neighbor pairwise interactions and a term involving the fourth moment of the electronic density of states. The model is in excellent agreement with recently published local...

  12. A New Method for Endoscopic Sampling of Submucosal Tissue in the Gastrointestinal Tract: A Comparison of the Biopsy Forceps and a New Drill Instrument.

    Science.gov (United States)

    Walther, Charles; Jeremiasen, Martin; Rissler, Pehr; Johansson, Jan L M; Larsson, Marie S; Walther, Bruno S C S

    2016-12-01

    Background Sampling of submucosal lesions in the gastrointestinal tract through a flexible endoscope is a well-recognized clinical problem. One technique often used is endoscopic ultrasound-guided fine-needle aspiration, but it does not provide solid tissue biopsies with preserved architecture for histopathological evaluation. To obtain solid tissue biopsies from submucosal lesions, we have constructed a new endoscopic biopsy tool and compared it in a crossover study with the standard double cupped forceps. Methods Ten patients with endoscopically verified submucosal lesions were sampled. The endoscopist selected the position for the biopsies and used the instrument selected by randomization. After a biopsy was harvested, the endoscopist chose the next site for a biopsy and again used the instrument picked by randomization. A total of 6 biopsies, 3 with the forceps and 3 with the drill instrument, were collected in every patient. Results The drill instrument resulted in larger total size biopsies (mm 2 ; Mann-Whitney U test, P = .048) and larger submucosal part (%) of the biopsies (Mann-Whitney U test, P = .003) than the forceps. Two patients were observed because of chest pain and suspicion of bleeding in 24 hours. No therapeutic measures were necessary to be taken. Conclusion The new drill instrument for flexible endoscopy can safely deliver submucosal tissue samples from submucosal lesions in the upper gastrointestinal tract. © The Author(s) 2016.

  13. Detailed characterization of a Comparative Reactivity Method (CRM) instrument for ambient OH reactivity measurements: experiments vs. modeling

    Science.gov (United States)

    Michoud, Vincent; Locoge, Nadine; Dusanter, Sébastien

    2015-04-01

    The Hydroxyl radical (OH) is the main daytime oxidant in the troposphere, leading to the oxidation of Volatile Organic Compounds (VOCs) and the formation of harmful pollutants such as ozone (O3) and Secondary Organic Aerosols (SOA). While OH plays a key role in tropospheric chemistry, recent studies have highlighted that there are still uncertainties associated with the OH budget, i.e the identification of sources and sinks and the quantification of production and loss rates of this radical. It has been demonstrated that ambient measurements of the total OH loss rate (also called total OH reactivity) can be used to identify and reduce these uncertainties. In this context, the Comparative Reactivity Method (CRM), developed by Sinha et al. (ACP, 2008), is a promising technique to measure total OH reactivity in ambient air and has already been used during several field campaigns. This technique relies on monitoring competitive reactions of OH with ambient trace gases and a reference compound (pyrrole) in a sampling reactor to derive ambient OH reactivity. However, this technique requires a complex data processing chain that has yet to be carefully investigated in the laboratory. In this study, we present a detailed characterization of a CRM instrument developed at Mines Douai, France. Experiments have been performed to investigate the dependence of the CRM response on humidity, ambient NOx levels, and the pyrrole-to-OH ratio inside the sampling reactor. Box modelling of the chemistry occurring in the reactor has also been performed to assess our theoretical understanding of the CRM measurement. This work shows that the CRM response is sensitive to both humidity and NOx, which can be accounted for during data processing using parameterizations depending on the pyrrole-to-OH ratio. The agreement observed between laboratory studies and model results suggests a good understanding of the chemistry occurring in the sampling reactor and gives confidence in the CRM

  14. Advanced Instrumentation and Control Methods for Small and Medium Reactors with IRIS Demonstration. Final Report. Volume 1

    International Nuclear Information System (INIS)

    Hines, J. Wesley; Upadhyaya, Belle R.; Doster, J. Michael; Edwards, Robert M.; Lewis, Kenneth D.; Turinsky, Paul; Coble, Jamie

    2011-01-01

    Development and deployment of small-scale nuclear power reactors and their maintenance, monitoring, and control are part of the mission under the Small Modular Reactor (SMR) program. The objectives of this NERI-consortium research project are to investigate, develop, and validate advanced methods for sensing, controlling, monitoring, diagnosis, and prognosis of these reactors, and to demonstrate the methods with application to one of the proposed integral pressurized water reactors (IPWR). For this project, the IPWR design by Westinghouse, the International Reactor Secure and Innovative (IRIS), has been used to demonstrate the techniques developed under this project. The research focuses on three topical areas with the following objectives. Objective 1 - Develop and apply simulation capabilities and sensitivity/uncertainty analysis methods to address sensor deployment analysis and small grid stability issues. Objective 2 - Develop and test an autonomous and fault-tolerant control architecture and apply to the IRIS system and an experimental flow control loop, with extensions to multiple reactor modules, nuclear desalination, and optimal sensor placement strategy. Objective 3 - Develop and test an integrated monitoring, diagnosis, and prognosis system for SMRs using the IRIS as a test platform, and integrate process and equipment monitoring (PEM) and process and equipment prognostics (PEP) toolboxes. The research tasks are focused on meeting the unique needs of reactors that may be deployed to remote locations or to developing countries with limited support infrastructure. These applications will require smaller, robust reactor designs with advanced technologies for sensors, instrumentation, and control. An excellent overview of SMRs is described in an article by Ingersoll (2009). The article refers to these as deliberately small reactors. Most of these have modular characteristics, with multiple units deployed at the same plant site. Additionally, the topics focus

  15. Resistive switching mechanism of ZnO/ZrO2-stacked resistive random access memory device annealed at 300 °C by sol-gel method with forming-free operation

    Science.gov (United States)

    Jian, Wen-Yi; You, Hsin-Chiang; Wu, Cheng-Yen

    2018-01-01

    In this work, we used a sol-gel process to fabricate a ZnO-ZrO2-stacked resistive switching random access memory (ReRAM) device and investigated its switching mechanism. The Gibbs free energy in ZnO, which is higher than that in ZrO2, facilitates the oxidation and reduction reactions of filaments in the ZnO layer. The current-voltage (I-V) characteristics of the device revealed a forming-free operation because of nonlattice oxygen in the oxide layer. In addition, the device can operate under bipolar or unipolar conditions with a reset voltage of 0 to ±2 V, indicating that in this device, Joule heating dominates at reset and the electric field dominates in the set process. Furthermore, the characteristics reveal why the fabricated device exhibits a greater discrete distribution phenomenon for the set voltage than for the reset voltage. These results will enable the fabrication of future ReRAM devices with double-layer oxide structures with improved characteristics.

  16. ANIMMA 2009 - International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications - Compilation of slides

    International Nuclear Information System (INIS)

    Chabre, A.; Lyoussi, A.; Martin-Deidier, L.; Caverni, J.P.; Deconinck, F.; Cesarsky, C.; Kjems, J.; Spiro, M.; Abdallah, J.; Mandic, I.; Cindro, V.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Hartert, J.; Bronner, J.; Franz, S.; Minano, M.; Fleta, C.; Garcia, C.; Lacasta, C.; Lozano, M.; Marco, R.; Marti, I.; Garcia, S.; Pellegrini, G.; Soldevila, U.; Ullan, M.; Larsen, R.; Downing, R.; Saunders, C.; Pavlicek, V.; Jezynski, T.; Rehlich, K.; An Liu, Z.; Nomachi, M.; Le Du, P.; Benekos, N.; Cortes Gonzales, A.; Coggeshall, J.; Liss, A.M.; Baudot, J.; Barbier, R.; Brogna, A.; Chabanat, E.; Claus, G.; Colledani, C.; Depasse, P.; Degerli, Y.; De Masi, R.; Deveaux, M.; Dorokhov, A.; Doziere, G.; Dritsa, C.; Dulinski, W.; Estre, N.; Fang, X.C.; Fontaine, J.C.; Gelin, M.; Goffe, M.; Himmi, A.; Hu-Guo, C.; Jaaskelainen, K.; Minano, M.; Bruynseraede, Y.; Benekos, N.; Collazuol, G.M.; Baudot, J.; Hoffmann, D.; Alami, R.; Marie, F.; Fontana, A.; Duval, P.Y.; Rosca, A.; Copic, K.; Iracane, D.; Rempe, J.; Shippen, D.; Choo, K.N.; Breitkreutz, H.; Petry, W.; Itagaki, W.; Zaristkiy, S.; Jammes, C.; Imel, G.; Ritter, G.; Casoli, P.; Blaise, P.; Lecouey, J.L.; Rohrmoser, A.; Bignan, G.; Bruynseraede, Y.; March, R.; Janulyte, A.; Morichi, M.; Adams, J.; Popov, V.; Costley, A.; Moreau, P.; Sabot, R.; Leyrat, J.P.; Angelone, M.; Flament, O.; Thfoin, I.; Boullis, B.; Rouquerol, J.; Nonell, A.; Simon, A.C.; Lyoussi, A.; De Bruycker, A.; Ducros, G.; Katsuyama, K.; Barat, E.; Swinhoe, M.; Dogny, S.; Carrel, F.; Granier, G.; Raoux, A.C.; Pluquet, A.; Ahlen, S.; Butchins, L.; Porta, A.; Valkovic, V.; Dazeley, S.; Furuta, H.; Quiter, B.; Piccotti, A.; Swinhoe, M.; Bruggeman, M.; Ruddy, F.; El kanawati, W.; Cabrera-Palmer, B.; Sweet, M.; Parrat, D.; Cavedon, J.M.; Babu, C.; Baskaran, B.; Villard, J.F.; Buimistriuc, G.; Rosenkrantz, E.; Coulon, R.; Schyns, M.; Bronson, F.; Giraud, A.; Vuillemard, C.; Ait Abderrahim, H.; Marie, F.; Beeley, P.; Andre, J.; Turpin, L.; Waker, A.; Pafilis, C.; Townsend, D.; Chatal, J.F.; Gao, W.; Kawachi, N.; Townsend, D.; Le Foulher, F.; Magne, S.; Valkovic, V.; Rottner, B.; Lebrun, A.; Ianakiev, K.; Giot, M.; Flescher, H.

    2009-01-01

    The program of this conference is focused on instrumentation, but emphasizes the latest developments in all measurement stages: nuclear radiation detection and in-pile measurements, modelling, electronics, signal acquisition and analysis, radiotherapy, interpretation and associated training activities. This document is composed of the program of the conference and of the slides of about 102 presentations

  17. Effects of Different Learning Methods for Instrumental Activities of Daily Living in Patients With Alzheimer's Dementia: A Pilot Study

    NARCIS (Netherlands)

    Dechamps, A.A.; Fasotti, L.; Jungheim, J.H.E.; Leone, E.; Dood, E.T.F.; Allioux, A.; Robert, P.H.; Gervais, X.; Maubourguet, N.; Olde Rikkert, M.G.M.; Kessels, R.P.C.

    2011-01-01

    We examined whether errorless learning (EL) and learning by modeling (LM) were more advantageous than trial and error learning (TEL) in the acquisition of instrumental activities of daily living (IADL) in Alzheimer’s dementia (AD) patients (n = 14). Using a counterbalanced within-subject design,

  18. Scale Marking Method on the Circumference of Circle Elements for Astronomical Instruments in the Early Joseon Dynasty

    Directory of Open Access Journals (Sweden)

    Byeong-Hee Mihn

    2015-03-01

    Full Text Available During the reign of King Sejong (世宗, 1418-1450 in the Joseon Dynasty, there were lots of astronomical instruments, including miniaturized ones. Those instruments utilized the technical know-how acquired through building contemporary astronomical instruments previously developed in the Song(宋, Jin(金, and Yuan(元 dynasties of China. In those days, many astronomical instruments had circles, rings, and spheres carved with a scale of 365.25, 100, and 24 parts, respectively, on their circumference. These were called the celestial-circumference degree, hundred-interval (Baekgak, and 24 direction, respectively. These scales are marked by the angular distance, not by the angle. Therefore, these circles, rings, and spheres had to be optimized in size to accomodate proper scales. Assuming that the scale system is composed of integer multiples of unit length, we studied the sizes of circles by referring to old articles and investigating existing artifacts. We discovered that the star chart of Cheonsang yeolcha bunyajido was drawn with a royal standard ruler (周尺 based on the unit length of 207 mm. Interestingly, its circumference was marked by the unit scale of 3 puns per 1 du (or degree like Honsang (a celestial globe. We also found that Hyeonju ilgu (a equatorial sundial has a Baekgak disk on a scale of 1 pun per 1 gak (that is an interval of time similar to a quarter. This study contributes to the analysis of specifications of numerous circular elements from old Korean astronomical instruments.

  19. AIC-based diffraction stacking for local earthquake locations at the Sumatran Fault (Indonesia)

    Science.gov (United States)

    Hendriyana, Andri; Bauer, Klaus; Muksin, Umar; Weber, Michael

    2018-05-01

    We present a new workflow for the localization of seismic events which is based on a diffraction stacking approach. In order to address the effects from complex source radiation patterns, we suggest to compute diffraction stacking from a characteristic function (CF) instead of stacking the original waveform data. A new CF, which is called in the following mAIC (modified from Akaike Information Criterion) is proposed. We demonstrate that both P- and S-wave onsets can be detected accurately. To avoid cross-talk between P and S waves due to inaccurate velocity models, we separate the P and S waves from the mAIC function by making use of polarization attributes. Then, the final image function is represented by the largest eigenvalue as a result of the covariance analysis between P- and S-image functions. Results from synthetic experiments show that the proposed diffraction stacking provides reliable results. The workflow of the diffraction stacking method was finally applied to local earthquake data from Sumatra, Indonesia. Recordings from a temporary network of 42 stations deployed for nine months around the Tarutung pull-apart basin were analysed. The seismic event locations resulting from the diffraction stacking method align along a segment of the Sumatran Fault. A more complex distribution of seismicity is imaged within and around the Tarutung basin. Two lineaments striking N-S were found in the centre of the Tarutung basin which support independent results from structural geology.

  20. Safety Evaluation of Radioactive Material Transport Package under Stacking Test Condition

    International Nuclear Information System (INIS)

    Lee, Ju Chan; Seo, Ki Seog; Yoo, Seong Yeon

    2012-01-01

    Radioactive waste transport package was developed to transport eight drums of low and intermediate level waste(LILW) in accordance with the IAEA and domestic related regulations. The package is classified with industrial package IP-2. IP-2 package is required to undergo a free drop test and a stacking test. After free drop and stacking tests, it should prevent the loss or dispersal of radioactive contents, and loss of shielding integrity which would result in more than 20 % increase in the radiation level at any external surface of the package. The objective of this study is to establish the safety test method and procedure for stacking test and to prove the structural integrities of the IP-2 package. Stacking test and analysis were performed with a compressive load equal to five times the weight of the package for a period of 24 hours using a full scale model. Strains and displacements were measured at the corner fitting of the package during the stacking test. The measured strains and displacements were compared with the analysis results, and there were good agreements. It is very difficult to measure the deflection at the container base, so the maximum deflection of the container base was calculated by the analysis method. The maximum displacement at the corner fitting and deflection at the container base were less than their allowable values. Dimensions of the test model, thickness of shielding material and bolt torque were measured before and after the stacking test. Throughout the stacking test, it was found that there were no loss or dispersal of radioactive contents and no loss of shielding integrity. Thus, the package was shown to comply with the requirements to maintain structural integrity under the stacking condition.

  1. Graphene controlled H- and J-stacking of perylene dyes into highly stable supramolecular nanostructures for enhanced photocurrent generation

    DEFF Research Database (Denmark)

    Gan, Shiyu; Zhong, Lijie; Engelbrekt, Christian

    2014-01-01

    We report a new method for controlling H- and J-stacking in supramolecular self-assembly. Graphene nanosheets act as structure inducers to direct the self-assembly of a versatile organic dye, perylene into two distinct types of functional nanostructures, i.e. one-dimensional nanotubes via J-stack......-junction solar cells.......We report a new method for controlling H- and J-stacking in supramolecular self-assembly. Graphene nanosheets act as structure inducers to direct the self-assembly of a versatile organic dye, perylene into two distinct types of functional nanostructures, i.e. one-dimensional nanotubes via J......-stacking and two-dimensional branched nanobuds through H-stacking. Graphene integrated supramolecular nanocomposites are highly stable and show significant enhancement of photocurrent generation in these two configurations of photosensing devices, i.e. solid-state optoelectronic constructs and liquid...

  2. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Šlampová, Andrea; Malá, Zdeňka; Pantůčková, Pavla; Gebauer, Petr; Boček, Petr

    2013-01-01

    Roč. 34, č. 1 (2013), s. 3-18 ISSN 0173-0835 R&D Projects: GA ČR GAP206/10/1219 Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.161, year: 2013

  3. SRS reactor stack plume marking tests

    International Nuclear Information System (INIS)

    Petry, S.F.

    1992-03-01

    Tests performed in 105-K in 1987 and 1988 demonstrated that the stack plume can successfully be made visible (i.e., marked) by introducing smoke into the stack breech. The ultimate objective of these tests is to provide a means during an emergency evacuation so that an evacuee can readily identify the stack plume and evacuate in the opposite direction, thus minimizing the potential of severe radiation exposure. The EPA has also requested DOE to arrange for more tests to settle a technical question involving the correct calculation of stack downwash. New test canisters were received in 1988 designed to produce more smoke per unit time; however, these canisters have not been evaluated, because normal ventilation conditions have not been reestablished in K Area. Meanwhile, both the authorization and procedure to conduct the tests have expired. The tests can be performed during normal reactor operation. It is recommended that appropriate authorization and procedure approval be obtained to resume testing after K Area restart

  4. Testing of Electrodes, Cells and Short Stacks

    DEFF Research Database (Denmark)

    Hauch, Anne; Mogensen, Mogens Bjerg

    2017-01-01

    The present contribution describes the electrochemical testing and characterization of electrodes, cells, and short stacks. To achieve the maximum insight and results from testing of electrodes and cells, it is obviously necessary to have a good understanding of the fundamental principles...

  5. Stack Gas Scrubber Makes the Grade

    Science.gov (United States)

    Chemical and Engineering News, 1975

    1975-01-01

    Describes a year long test of successful sulfur dioxide removal from stack gas with a calcium oxide slurry. Sludge disposal problems are discussed. Cost is estimated at 0.6 mill per kwh not including sludge removal. A flow diagram and equations are included. (GH)

  6. OpenStack Object Storage (Swift) essentials

    CERN Document Server

    Kapadia, Amar; Varma, Sreedhar

    2015-01-01

    If you are an IT administrator and you want to enter the world of cloud storage using OpenStack Swift, then this book is ideal for you. Basic knowledge of Linux and server technology is beneficial to get the most out of the book.

  7. Stacked spheres and lower bound theorem

    Indian Academy of Sciences (India)

    BASUDEB DATTA

    2011-11-20

    Nov 20, 2011 ... Preliminaries. Lower bound theorem. On going work. Definitions. An n-simplex is a convex hull of n + 1 affinely independent points. (called vertices) in some Euclidean space R. N . Stacked spheres and lower bound theorem. Basudeb Datta. Indian Institute of Science. 2 / 27 ...

  8. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Malá, Zdeňka; Šlampová, Andrea; Křivánková, Ludmila; Gebauer, Petr; Boček, Petr

    2015-01-01

    Roč. 36, č. 1 (2015), s. 15-35 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.482, year: 2015

  9. The data type variety of stack algebras

    NARCIS (Netherlands)

    Bergstra, J.A.; Tucker, J.V.

    1995-01-01

    We define and study the class of all stack algebras as the class of all minimal algebras in a variety defined by an infinite recursively enumerable set of equations. Among a number of results, we show that the initial model of the variety is computable, that its equational theory is decidable,

  10. Photoswitchable Intramolecular H-Stacking of Perylenebisimide

    NARCIS (Netherlands)

    Wang, Jiaobing; Kulago, Artem; Browne, Wesley R.; Feringa, Ben L.

    2010-01-01

    Dynamic control over the formation of H- or J-type aggregates of chromophores is of fundamental importance for developing responsive organic optoelectronic materials. In this study, the first example of photoswitching between a nonstacked and an intramolecularly H-stacked arrangement of

  11. 40 CFR 61.53 - Stack sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.53 Section 61.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Mercury ore processing facility. (1) Unless a waiver of emission testing is obtained under...

  12. 40 CFR 61.33 - Stack sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...

  13. OpenStack cloud computing cookbook

    CERN Document Server

    Jackson, Kevin

    2013-01-01

    A Cookbook full of practical and applicable recipes that will enable you to use the full capabilities of OpenStack like never before.This book is aimed at system administrators and technical architects moving from a virtualized environment to cloud environments with familiarity of cloud computing platforms. Knowledge of virtualization and managing linux environments is expected.

  14. Methods and apparatus for cleaning objects in a chamber of an optical instrument by generating reactive ions using photon radiation

    Science.gov (United States)

    Klebanoff, Leonard E.; Delgado, Gildardo R.; Hollenshead, Jeromy T.; Umstadter, Karl R.; Starodub, Elena; Zhuang, Guorong V.

    2015-10-13

    An optical instrument, including a chamber, an object exposed to an interior of the chamber, a source of low-pressure gas, the gas comprising at least one of low-pressure molecular hydrogen gas, low-pressure molecular oxygen and a low-pressure noble gas, the source of low pressure gas being fluidly coupled to the chamber, a low voltage source electrically coupled between the object and a remaining portion of the instrument that is exposed to the interior of the chamber so as to maintain the object at a low voltage relative to the remaining portion, and an EUV/VUV light source adapted to direct EUV/VUV light through the low pressure gas in the chamber onto the object. In such a system, when the EUV/VUV light source is activated ions of the low-pressure gas are formed and directed to the object. The ions may be ions of Hydrogen, Oxygen or a noble gas.

  15. New Methods for Retrieval of Chlorophyll Red Fluorescence from Hyperspectral Satellite Instruments: Simulations and Application to GOME-2 and SCIAMACHY

    Science.gov (United States)

    Joiner, Joanna; Yoshida, Yasuko; Guanter, Luis; Middleton, Elizabeth M.

    2016-01-01

    Global satellite measurements of solar-induced fluorescence (SIF) from chlorophyll over land and ocean have proven useful for a number of different applications related to physiology, phenology, and productivity of plants and phytoplankton. Terrestrial chlorophyll fluorescence is emitted throughout the red and far-red spectrum, producing two broad peaks near 683 and 736nm. From ocean surfaces, phytoplankton fluorescence emissions are entirely from the red region (683nm peak). Studies using satellite-derived SIF over land have focused almost exclusively on measurements in the far red (wavelengths greater than 712nm), since those are the most easily obtained with existing instrumentation. Here, we examine new ways to use existing hyperspectral satellite data sets to retrieve red SIF (wavelengths less than 712nm) over both land and ocean. Red SIF is thought to provide complementary information to that from the far red for terrestrial vegetation. The satellite instruments that we use were designed to make atmospheric trace-gas measurements and are therefore not optimal for observing SIF; they have coarse spatial resolution and only moderate spectral resolution (0.5nm). Nevertheless, these instruments, the Global Ozone Monitoring Instrument 2 (GOME-2) and the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY), offer a unique opportunity to compare red and far-red terrestrial SIF at regional spatial scales. Terrestrial SIF has been estimated with ground-, aircraft-, or satellite-based instruments by measuring the filling-in of atmospheric andor solar absorption spectral features by SIF. Our approach makes use of the oxygen (O2) gamma band that is not affected by SIF. The SIF-free O2 gamma band helps to estimate absorption within the spectrally variable O2 B band, which is filled in by red SIF. SIF also fills in the spectrally stable solar Fraunhofer lines (SFLs) at wavelengths both inside and just outside the O2 B band, which further helps

  16. Analysing Protocol Stacks for Services

    DEFF Research Database (Denmark)

    Gao, Han; Nielson, Flemming; Nielson, Hanne Riis

    2011-01-01

    We show an approach, CaPiTo, to model service-oriented applications using process algebras such that, on the one hand, we can achieve a certain level of abstraction without being overwhelmed by the underlying implementation details and, on the other hand, we respect the concrete industrial...... standards used for implementing the service-oriented applications. By doing so, we will be able to not only reason about applications at different levels of abstractions, but also to build a bridge between the views of researchers on formal methods and developers in industry. We apply our approach...

  17. The computational optimization of heat exchange efficiency in stack chimneys

    Energy Technology Data Exchange (ETDEWEB)

    Van Goch, T.A.J.

    2012-02-15

    For many industrial processes, the chimney is the final step before hot fumes, with high thermal energy content, are discharged into the atmosphere. Tapping into this energy and utilizing it for heating or cooling applications, could improve sustainability, efficiency and/or reduce operational costs. Alternatively, an unused chimney, like the monumental chimney at the Eindhoven University of Technology, could serve as an 'energy channeler' once more; it can enhance free cooling by exploiting the stack effect. This study aims to identify design parameters that influence annual heat exchange in such stack chimney applications and optimize these parameters for specific scenarios to maximize the performance. Performance is defined by annual heat exchange, system efficiency and costs. The energy required for the water pump as compared to the energy exchanged, defines the system efficiency, which is expressed in an efficiency coefficient (EC). This study is an example of applying building performance simulation (BPS) tools for decision support in the early phase of the design process. In this study, BPS tools are used to provide design guidance, performance evaluation and optimization. A general method for optimization of simulation models will be studied, and applied in two case studies with different applications (heating/cooling), namely; (1) CERES case: 'Eindhoven University of Technology monumental stack chimney equipped with a heat exchanger, rejects heat to load the cold source of the aquifer system on the campus of the university and/or provides free cooling to the CERES building'; and (2) Industrial case: 'Heat exchanger in an industrial stack chimney, which recoups heat for use in e.g. absorption cooling'. The main research question, addressing the concerns of both cases, is expressed as follows: 'what is the optimal set of design parameters so heat exchange in stack chimneys is optimized annually for the cases in which a

  18. A method and instruments to identify the torque, the power and the efficiency of an internal combustion engine of a wheeled vehicle

    Science.gov (United States)

    Egorov, A. V.; Kozlov, K. E.; Belogusev, V. N.

    2018-01-01

    In this paper, we propose a new method and instruments to identify the torque, the power, and the efficiency of internal combustion engines in transient conditions. This method, in contrast to the commonly used non-demounting methods based on inertia and strain gauge dynamometers, allows controlling the main performance parameters of internal combustion engines in transient conditions without inaccuracy connected with the torque loss due to its transfer to the driving wheels, on which the torque is measured with existing methods. In addition, the proposed method is easy to create, and it does not use strain measurement instruments, the application of which does not allow identifying the variable values of the measured parameters with high measurement rate; and therefore the use of them leads to the impossibility of taking into account the actual parameters when engineering the wheeled vehicles. Thus the use of this method can greatly improve the measurement accuracy and reduce costs and laboriousness during testing of internal combustion engines. The results of experiments showed the applicability of the proposed method for identification of the internal combustion engines performance parameters. In this paper, it was determined the most preferred transmission ratio when using the proposed method.

  19. Fast static field CIPT mapping of unpatterned MRAM film stacks

    Science.gov (United States)

    Kjaer, Daniel; Hansen, Ole; Hartmann Henrichsen, Henrik; Chenchen, Jacob Wang; Noergaard, Kristian; Folmer Nielsen, Peter; Hjorth Petersen, Dirch

    2015-04-01

    While investigating uniformity of magnetic tunnel junction (MTJ) stacks we find experimentally and analytically that variation in the resistance area product (RA) is more important to monitor as compared to the tunnel magnetoresistance (TMR), which is less sensitive to MTJ variability. The standard Current In-Plane Tunneling (CIPT) method measures both RA and TMR, but the usefulness for uniformity mapping, e.g. for tool optimization, is limited by excessive measurement time. Thus, we develop and demonstrate a fast complementary static magnetic field method focused only on measurement of RA. We compare the static field method to the standard CIPT method and find perfect agreement between the extracted RA values and measurement repeatability while the static field method is several times faster. The static field CIPT method is demonstrated for 200 mm wafer mapping showing radial as well as asymmetrical variations related to the MTJ deposition conditions.

  20. Moving object detection in top-view aerial videos improved by image stacking

    Science.gov (United States)

    Teutsch, Michael; Krüger, Wolfgang; Beyerer, Jürgen

    2017-08-01

    Image stacking is a well-known method that is used to improve the quality of images in video data. A set of consecutive images is aligned by applying image registration and warping. In the resulting image stack, each pixel has redundant information about its intensity value. This redundant information can be used to suppress image noise, resharpen blurry images, or even enhance the spatial image resolution as done in super-resolution. Small moving objects in the videos usually get blurred or distorted by image stacking and thus need to be handled explicitly. We use image stacking in an innovative way: image registration is applied to small moving objects only, and image warping blurs the stationary background that surrounds the moving objects. Our video data are coming from a small fixed-wing unmanned aerial vehicle (UAV) that acquires top-view gray-value images of urban scenes. Moving objects are mainly cars but also other vehicles such as motorcycles. The resulting images, after applying our proposed image stacking approach, are used to improve baseline algorithms for vehicle detection and segmentation. We improve precision and recall by up to 0.011, which corresponds to a reduction of the number of false positive and false negative detections by more than 3 per second. Furthermore, we show how our proposed image stacking approach can be implemented efficiently.

  1. Reliability prediction of large fuel cell stack based on structure stress analysis

    Science.gov (United States)

    Liu, L. F.; Liu, B.; Wu, C. W.

    2017-09-01

    The aim of this paper is to improve the reliability of Proton Electrolyte Membrane Fuel Cell (PEMFC) stack by designing the clamping force and the thickness difference between the membrane electrode assembly (MEA) and the gasket. The stack reliability is directly determined by the component reliability, which is affected by the material property and contact stress. The component contact stress is a random variable because it is usually affected by many uncertain factors in the production and clamping process. We have investigated the influences of parameter variation coefficient on the probability distribution of contact stress using the equivalent stiffness model and the first-order second moment method. The optimal contact stress to make the component stay in the highest level reliability is obtained by the stress-strength interference model. To obtain the optimal contact stress between the contact components, the optimal thickness of the component and the stack clamping force are optimally designed. Finally, a detailed description is given how to design the MEA and gasket dimensions to obtain the highest stack reliability. This work can provide a valuable guidance in the design of stack structure for a high reliability of fuel cell stack.

  2. A New Method and Mass-Spectrometric Instrument for Extraterrestrial Microbial Life Detection Using the Elemental Composition Analyses of Martian Regolith and Permafrost/Ice.

    Science.gov (United States)

    Managadze, G G; Safronova, A A; Luchnikov, K A; Vorobyova, E A; Duxbury, N S; Wurz, P; Managadze, N G; Chumikov, A E; Khamizov, R Kh

    2017-05-01

    We propose a new technique for the detection of microorganisms by elemental composition analyses of a sample extracted from regolith, permafrost, and ice of extraterrestrial bodies. We also describe the design of the ABIMAS instrument, which consists of the onboard time-of-flight laser mass-reflectron (TOF LMR) and the sample preparation unit (SPU) for biomass extraction. This instrument was initially approved to fly on board the ExoMars 2020 lander mission. The instrument can be used to analyze the elemental composition of possible extraterrestrial microbial communities and compare it to that of terrestrial microorganisms. We have conducted numerous laboratory studies to confirm the possibility of biomass identification via the following biomarkers: P/S and Ca/K ratios, and C and N abundances. We underline that only the combination of these factors will allow one to discriminate microbial samples from geological ones. Our technique has been tested experimentally in numerous laboratory trials on cultures of microorganisms and polar permafrost samples as terrestrial analogues for martian polar soils. We discuss various methods of extracting microorganisms and sample preparation. The developed technique can be used to search for and identify microorganisms in different martian samples and in the subsurface of other planets, satellites, comets, and asteroids-in particular, Europa, Ganymede, and Enceladus. Key Words: Mass spectrometry-Life-detection instruments-Biomarkers-Earth Mars-Biomass spectra. Astrobiology 17, 448-458.

  3. Nanocomposite Materials of Alternately Stacked C60 Monolayer and Graphene

    International Nuclear Information System (INIS)

    Ishikawa, M.; Miura, K.; Kamiya, S.; Yoshimoto, S.; Suzuki, M.; Kuwahara, D.; Sasaki, N.

    2010-01-01

    We synthesized the novel nanocomposite consisting alternately of a stacked single graphene sheet and a C 60 monolayer by using the graphite intercalation technique in which alkylamine molecules help intercalate large C 60 molecules into the graphite. Moreover, it is found that the intercalated C 60 molecules can rotate in between single graphene sheets by using C 13 NMR measurements. This preparation method provides a general way for intercalating huge fullerene molecules into graphite, which will lead to promising materials with novel mechanical, physical, and electrical properties.

  4. Nanocomposite Materials of Alternately Stacked C60 Monolayer and Graphene

    Directory of Open Access Journals (Sweden)

    Makoto Ishikawa

    2010-01-01

    Full Text Available We synthesized the novel nanocomposite consisting alternately of a stacked single graphene sheet and a C60 monolayer by using the graphite intercalation technique in which alkylamine molecules help intercalate large C60 molecules into the graphite. Moreover, it is found that the intercalated C60 molecules can rotate in between single graphene sheets by using C13 NMR measurements. This preparation method provides a general way for intercalating huge fullerene molecules into graphite, which will lead to promising materials with novel mechanical, physical, and electrical properties.

  5. Project W-420 Stack Monitoring system upgrades conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    TUCK, J.A.

    1998-11-06

    This document describes the scope, justification, conceptual design, and performance of Project W-420 stack monitoring system upgrades on six NESHAP-designated, Hanford Tank Farms ventilation exhaust stacks.

  6. Heuristic Solution Approaches to the Double TSP with Multiple Stacks

    DEFF Research Database (Denmark)

    Petersen, Hanne Løhmann

    This paper introduces the Double Travelling Salesman Problem with Multiple Stacks and presents a three different metaheuristic approaches to its solution. The Double Travelling Salesman Problem with Multiple Stacks is concerned with finding the shortest route performing pickups and deliveries...

  7. Heuristic Solution Approaches to the Double TSP with Multiple Stacks

    DEFF Research Database (Denmark)

    Petersen, Hanne Løhmann

    2006-01-01

    This paper introduces the Double Travelling Salesman Problem with Multiple Stacks and presents a three different metaheuristic approaches to its solution. The Double Travelling Salesman Problem with Multiple Stacks is concerned with finding the shortest route performing pickups and deliveries...

  8. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  9. An Instrumented Macro-Indentation Method for Determining the Mechanical Properties of Coconut Shell (Coco Nucifera of Cameroon)

    OpenAIRE

    Njeugna, E.; Ganou, M.B.K.; Ndapeu, D.; Foba, J.N.T.; Sikame , N.R.T.; Huisken , P.W.M.

    2016-01-01

    International audience; An instrumented macro-indentation test was used to determine the viscoelastic parameters and hardness of the shell of Coco Nucifera from Cameroon in order to promote their use in the manufacture of abrasives. Samples measuring 10 mm x 10 mm x 3 mm were cut out from the bottom of the fruit, close to the natural indentations (the eye) of an approximately round-shaped fruit. The indentation load ranged from 50 to 500 N with an increment of 50 N. A comparator with digital ...

  10. [Detection of recombinant-DNA in foods from stacked genetically modified plants].

    Science.gov (United States)

    Sorokina, E Iu; Chernyshova, O N

    2012-01-01

    A quantitative real-time multiplex polymerase chain reaction method was applied to the detection and quantification of MON863 and MON810 in stacked genetically modified maize MON 810xMON 863. The limit of detection was approximately 0,1%. The accuracy of the quantification, measured as bias from the accepted value and the relative repeatability standard deviation, which measures the intra-laboratory variability, were within 25% at each GM-level. A method verification has demonstrated that the MON 863 and the MON810 methods can be equally applied in quantification of the respective events in stacked MON810xMON 863.

  11. Formation of stacking faults and the screw dislocation-driven growth: a case study of aluminum nitride nanowires.

    Science.gov (United States)

    Meng, Fei; Estruga, Marc; Forticaux, Audrey; Morin, Stephen A; Wu, Qiang; Hu, Zheng; Jin, Song

    2013-12-23

    Stacking faults are an important class of crystal defects commonly observed in nanostructures of close packed crystal structures. They can bridge the transition between hexagonal wurtzite (WZ) and cubic zinc blende (ZB) phases, with the most known example represented by the "nanowire (NW) twinning superlattice". Understanding the formation mechanisms of stacking faults is crucial to better control them and thus enhance the capability of tailoring physical properties of nanomaterials through defect engineering. Here we provide a different perspective to the formation of stacking faults associated with the screw dislocation-driven growth mechanism of nanomaterials. With the use of NWs of WZ aluminum nitride (AlN) grown by a high-temperature nitridation method as the model system, dislocation-driven growth was first confirmed by transmission electron microscopy (TEM). Meanwhile numerous stacking faults and associated partial dislocations were also observed and identified to be the Type I stacking faults and the Frank partial dislocations, respectively, using high-resolution TEM. In contrast, AlN NWs obtained by rapid quenching after growth displayed no stacking faults or partial dislocations; instead many of them had voids that were associated with the dislocation-driven growth. On the basis of these observations, we suggest a formation mechanism of stacking faults that originate from dislocation voids during the cooling process in the syntheses. Similar stacking fault features were also observed in other NWs with WZ structure, such as cadmium sulfide (CdS) and zinc oxide (ZnO).

  12. Sport stacking motor intervention programme for children with ...

    African Journals Online (AJOL)

    The purpose of this study was to explore sport stacking as an alternative intervention approach with typically developing children and in addition to improve DCD. Sport stacking consists of participants stacking and unstacking 12 specially designed plastic cups in predetermined sequences in as little time as possible.

  13. Annular feed air breathing fuel cell stack

    Science.gov (United States)

    Wilson, Mahlon S.

    1996-01-01

    A stack of polymer electrolyte fuel cells is formed from a plurality of unit cells where each unit cell includes fuel cell components defining a periphery and distributed along a common axis, where the fuel cell components include a polymer electrolyte membrane, an anode and a cathode contacting opposite sides of the membrane, and fuel and oxygen flow fields contacting the anode and the cathode, respectively, wherein the components define an annular region therethrough along the axis. A fuel distribution manifold within the annular region is connected to deliver fuel to the fuel flow field in each of the unit cells. In a particular embodiment, a single bolt through the annular region clamps the unit cells together. In another embodiment, separator plates between individual unit cells have an extended radial dimension to function as cooling fins for maintaining the operating temperature of the fuel cell stack.

  14. System for inspection of stacked cargo containers

    Science.gov (United States)

    Derenzo, Stephen [Pinole, CA

    2011-08-16

    The present invention relates to a system for inspection of stacked cargo containers. One embodiment of the invention generally comprises a plurality of stacked cargo containers arranged in rows or tiers, each container having a top, a bottom a first side, a second side, a front end, and a back end; a plurality of spacers arranged in rows or tiers; one or more mobile inspection devices for inspecting the cargo containers, wherein the one or more inspection devices are removeably disposed within the spacers, the inspection means configured to move through the spacers to detect radiation within the containers. The invented system can also be configured to inspect the cargo containers for a variety of other potentially hazardous materials including but not limited to explosive and chemical threats.

  15. Radiation-Tolerant Intelligent Memory Stack - RTIMS

    Science.gov (United States)

    Ng, Tak-kwong; Herath, Jeffrey A.

    2011-01-01

    This innovation provides reconfigurable circuitry and 2-Gb of error-corrected or 1-Gb of triple-redundant digital memory in a small package. RTIMS uses circuit stacking of heterogeneous components and radiation shielding technologies. A reprogrammable field-programmable gate array (FPGA), six synchronous dynamic random access memories, linear regulator, and the radiation mitigation circuits are stacked into a module of 42.7 42.7 13 mm. Triple module redundancy, current limiting, configuration scrubbing, and single- event function interrupt detection are employed to mitigate radiation effects. The novel self-scrubbing and single event functional interrupt (SEFI) detection allows a relatively soft FPGA to become radiation tolerant without external scrubbing and monitoring hardware

  16. Absorption spectra of AA-stacked graphite

    International Nuclear Information System (INIS)

    Chiu, C W; Lee, S H; Chen, S C; Lin, M F; Shyu, F L

    2010-01-01

    AA-stacked graphite shows strong anisotropy in geometric structures and velocity matrix elements. However, the absorption spectra are isotropic for the polarization vector on the graphene plane. The spectra exhibit one prominent plateau at middle energy and one shoulder structure at lower energy. These structures directly reflect the unique geometric and band structures and provide sufficient information for experimental fitting of the intralayer and interlayer atomic interactions. On the other hand, monolayer graphene shows a sharp absorption peak but no shoulder structure; AA-stacked bilayer graphene has two absorption peaks at middle energy and abruptly vanishes at lower energy. Furthermore, the isotropic features are expected to exist in other graphene-related systems. The calculated results and the predicted atomic interactions could be verified by optical measurements.

  17. Development of on-site PAFC stacks

    Energy Technology Data Exchange (ETDEWEB)

    Hotta, K.; Matsumoto, Y. [Kansai Electric Power Co., Amagasaki (Japan); Horiuchi, H.; Ohtani, T. [Mitsubishi Electric Corp., Kobe (Japan)

    1996-12-31

    PAFC (Phosphoric Acid Fuel Cell) has been researched for commercial use and demonstration plants have been installed in various sites. However, PAFC don`t have a enough stability yet, so more research and development must be required in the future. Especially, cell stack needs a proper state of three phases (liquid, gas and solid) interface. It is very difficult technology to keep this condition for a long time. In the small size cell with the electrode area of 100 cm{sup 2}, gas flow and temperature distributions show uniformity. But in the large size cell with the electrode area of 4000 cm{sup 2}, the temperature distributions show non-uniformity. These distributions would cause to be shorten the cell life. Because these distributions make hot-spot and gas poverty in limited parts. So we inserted thermocouples in short-stack for measuring three-dimensional temperature distributions and observed effects of current density and gas utilization on temperature.

  18. Hyperspectral anomaly detection based on stacked denoising autoencoders

    Science.gov (United States)

    Zhao, Chunhui; Li, Xueyuan; Zhu, Haifeng

    2017-10-01

    Hyperspectral anomaly detection (AD) is an important technique of unsupervised target detection and has significance in real situations. Due to the high dimensionality of hyperspectral data, AD will be influenced by noise, nonlinear correlation of band, or other factors that lead to the decline of detection accuracy. To overcome this problem, a method of hyperspectral AD based on stacked denoising autoencoders (AE) (HADSDA) is proposed. Simultaneously, two different feature detection models, spectral feature (SF) and fused feature by clustering (FFC), are constructed to verify the effectiveness of the proposed algorithm. The SF detection model uses the SF of each pixel. The FFC detection model uses a similar set of pixels constructed by clustering and then fuses the set of pixels by the stacked denoising autoencoders algorithm (SDA). The SDA is an algorithm that can automatically learn nonlinear deep features of the image. Compared with other linear or nonlinear feature extraction methods, the detection result of the proposed algorithm is greatly improved. Experiment results show that the proposed algorithm is an excellent feature learning method and can achieve higher detection performance.

  19. Nuclear medicine and image research: instrumentation and quantitative methods of evaluation. Comprehensive 3-year progress report, January 15, 1983-January 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This program of research addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation, and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. Project I addresses problems with the quantitative imaging a single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures

  20. Analysis for trace mercury concentration. I. Critical evaluation of current procedures. II. A proposed method for determination by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Litman, R.

    1975-01-01

    Current methods of sample pretreatments, digestion, lyophilization and extraction, have been found to lead to considerable loss of mercury, at an initial mercury concentration of 1 μg/g, and less. Storage of solutions of mercury at concentrations of less than 1 μg/ml, in glass, Teflon and polyethylene containers, leads to losses by adsorption. Electrochemical reduction of mercury to the metal, and subsequent volatilization, is postulated as the mechanism of loss from the samples studied during lyophilization. A method of instrumental neutron activation analysis, which obviates the above pretreatments, has been developed for mercury concentrations as low as 1 ng/ml