WorldWideScience

Sample records for stabilized helium-neon laser

  1. Helium-neon laser stabilized by saturated absorption in iodine at 612 nm.

    Science.gov (United States)

    Cérez, P; Bennett, S J

    1979-04-01

    Hyperfine structure of iodine has been studied at 612 nm by the technique of saturated absorption in an iodine cell placed in a He-Ne laser modified to operate at this wavelength. The most interesting feature of the laser is the existence of strong inverted Lamb dips at a very low vapor pressure, which provides very good short term frequency stability. Some factors which limit the reproducibility of the device are also investigated.

  2. Helium Neon laser therapy for post mastectomy lymphedema and ...

    African Journals Online (AJOL)

    The aim of this work was to evaluate the efficacy of Helium Neon (He–Ne) laser therapy on post mastectomy lymphedema and shoulder mobility. Thirty female patients with axillary lymph node dissection (ALND), with or without radiotherapy had been participated in this study. The patients were randomly divided into two ...

  3. Molecular Iodine Fluorescence Using a Green Helium-Neon Laser

    Science.gov (United States)

    Williamson, J. Charles

    2011-01-01

    Excitation of molecular iodine vapor with a green (543.4 nm) helium-neon laser produces a fluorescence spectrum that is well suited for the upper-level undergraduate physical chemistry laboratory. Application of standard evaluation techniques to the spectrum yields ground electronic-state molecular parameters in good agreement with literature…

  4. Photobiological effects of helium neon laser on hematologic and biochemical factors of rabbit blood

    Directory of Open Access Journals (Sweden)

    J Rahmani Kahnamoei

    2008-11-01

    Full Text Available Low-level helium neon laser has many applications due to its photobiostimulatory effects. Although the therapeutic effects of low-level laser radiation of different wavelengths and doses are well known, but the exact mechanism of action of the laser radiation on living cells is not yet determined. The present study is designed to evaluate the photobiological effects of 2 mw helium neon laser with wavelength of 632.8 nm on hematologic and biochemical factors of rabbit blood for this purpose, 30 male New Zealand white rabbits with the body weight of 1/5-2 kg were randomly allocated into two groups of control and laser treatment. Animals of both groups were anesthetized and those of laser treatment group were subjected to irradiation with helium neon laser at a                        wavelength of 632.8 nm and output 2 mw for 30 minutes. Finally blood samples were collected from all animals and the biochemical and hematologic factors evaluated. Significant difference (p

  5. Results of presowing helium-neon-laser irradiation of sunflower seeds

    International Nuclear Information System (INIS)

    Tsvetanova, K.

    1989-01-01

    In the period of 1983-1985 under non-irrigation, on calcareous chernozem a trial was carried out with the Start hybrid through single-, double-and triple irradiation of the seeds being stored for 1.8 and 16 days prior to sowing. It is found that the presowing helium-neon-laser irradiation of the sunflower seeds of the Start hybrid exerts a negative effect on the seed yield. Laser use does not stimulate the following: emerged seeds and percentage of the plants being in blossom in the beginning of the phase and after 7 days, seed moisture in harvesting and oil content in them

  6. Experimental study of the effects of helium-neon laser radiation on repair of injured tendon

    Science.gov (United States)

    Xu, Yong-Qing; Li, Zhu-Yi; Weng, Long-Jiang; An, Mei; Li, Kai-Yun; Chen, Shao-Rong; Wang, Jian-Xin; Lu, Yu

    1993-03-01

    Despite extensive research into the biology of tendon healing, predictably restoring normal function to a digit after a flexor tendon laceration remains one of the most difficult problems facing the hand surgeon. The challenge of simultaneously achieving tendon healing while minimizing the peritendinous scar formation, which limits tendon gliding, has captured the attention of investigators for many years. It has been said that low-power density helium-neon laser radiation had effects on anti-inflammation, detumescence, progressive wound healing, and reducing intestinal adhesions. This experimental study aims at whether helium-neon laser can reduce injured tendon adhesions and improve functional recovery of the injured tendon. Fifty white Leghorn hens were used. Ten were randomly assigned as a normal control group, the other forty were used in the operation. After anesthetizing them with Amytal, a half of the profundus tendons of the second and third foretoes on both sides of the feet were cut. Postoperatively, the hens moved freely in the cages. One side of the toes operated on were randomly chosen as a treatment group, the other side served as an untreated control group. The injured tendon toes in the treatment group were irradiated for twenty minutes daily with a fiber light needle of helium-neon laser therapeutic apparatus (wavelength, 6328 angstroms) at a constant power density of 12.74 mW/cm2, the first exposure taking place 24 hours after the operation. The longest course of treatment was 3 weeks. The control group was not irradiated. At 3 days, 1, 2, 3, and 5 weeks after surgery, 8 hens were sacrificed and their tendons were examined. The experimental results: (1) active, passive flexion and tendon gliding functional recovery were significantly better in the treatment group (p < 0.01); (2) width and thickness of the tendon at the cut site were significantly smaller in the treatment group (p < 0.01); (3) degrees of tendon adhesions were significantly lighter

  7. Photobiomodulation by helium neon and diode lasers in an excisional wound model: A single blinded trial

    Directory of Open Access Journals (Sweden)

    Snehil Dixit

    2012-01-01

    Full Text Available Background: Application of different kinds of lasers in clinical and experimental studies causes photobiomodulation that works at localized cellular and humoral level on various biological systems. Increased numbers of fibroblasts, myofibroblast, and degranulation of mast cells have been the observed benefits post-irradiation. Objective: Was to find out the effect of irradiation with energy densities of 3.38 J/cm 2 , 8 J/cm 2 , and 18 J/cm 2 on animal tissue (albino wistar rats in an excisional wound model and to assess changes in biochemical (hydroxyproline and histopathological levels in excisional wound model. Materials and Methods: The animals were divided into 4 groups, which were labeled as L1, diode laser (18 J/cm 2 , L2 Helium-neon (He-Ne, 8 J/cm 2 , L3 diode laser (3.38 J/cm 2 , and sham treatment for control was depicted by C, respectively. Histological and hydroxyproline analysis was performed on 7, 14, 21 days of post-wounding. One-way analysis of variance, ANOVA and Bonferroni′s multiple comparison tests were done for tissue hydroxyproline levels. Results: There was no significant increase in the hydroxyproline content (P < 0.005 when observed in study group and compared to controls. Whereas significant epithelizations was seen in group treated with He-Ne laser of intensity of 8 J/cm 2 . Conclusion: The experimental observations suggest that low intensity helium-neon laser of 8 J/cm 2 intensity facilitated photo stimulation by tissue repair, but failed to show significant tissue hydroxyproline levels in excisional wound model.

  8. Prospects For The Helium-Neon Laser Through The End Of The Century

    Science.gov (United States)

    Knollenberg, Robert G.

    1987-04-01

    The He-Ne laser has seen a developmental renaissance in recent years. Whereas ten years ago technologists had predicted its extinction by today, it has in fact become all the more ubiquitous and survived strong threats from solid state sources, unfolded a broad rainbow of new lines, and reformed itself into more useful envelopes. Today, the He-Ne laser appears to be well entrenched to survive and proliferate into the 1990's and the end of the second millennium. The historical development of the He-Ne laser is revisited emphasizing critical techno-logical paths enroute to today's device. Hard-sealing introduced during the last decade has been the primary factor extending tube life into the tens of thousands of hours range. The availability of higher quality optics has been critical to the construction of resona-tors capable of sustaining the low-gain green (543nm), yellow (594nm), and orange (612nm) lines at useful powers. An overview of multiline, infrared, and color selectable (tunable) devices is presented. New applications for He-Ne lasers, especially the non-red wavelengths, are discussed. Particular focus is given to 633nm resonator cavity structures which have come to dominate airborne particle size measurements and ring laser gyros (RLG). The close proximity of the green (543nm) and yellow (594nm) lines to excitation of prominent fluorescent dyes is seen to potentially open numerous medical markets. Other applications in photochemistry, micro-surgery, photolithography, and the visual arts are also emerging. When combined with several new infrared He-Ne lines, there promises to be a strong future for tomorrow's He-Ne laser.

  9. [Evaluation of macular functional capacity by helium-neon laser interferometry].

    Science.gov (United States)

    Schraub, M; Flament, J; Sahel, J; Bronner, A

    1985-01-01

    We describe the principles of the measure of visual acuity by using the laser interference retinometer. Interference fringes are projected on the retina, with variation of direction and thickness varied, to study the functional capacity of the macula. This method is particularly useful in patients with cataracts, because it is much less influenced by the clarity of the media than Snellen chart listing. We give the results of a series of 122 eyes with cataract, comparing pre-operative laser acuity and post-operative Snellen visual acuity. The pre-operative interfermometric measure is possible in 77% of the cases, but in most cases of mature cataract or dense posterior subcapsular opacities, the patients do not discern any interference fringes. In immature cataracts according to other results of the literature, post-operative Snellen visual acuity reaches preoperative laser acuity in 60% of the cases, and is better in 29% of the cases. Clinical conditions such as macular degeneration, cystoid macular oedema, amblyopia, visual field cuts through fixation or myopic choroïdopathy, may make the interferometer test unreliable.

  10. Low-level laser therapy with helium-neon laser improved viability of osteoporotic bone marrow-derived mesenchymal stem cells from ovariectomy-induced osteoporotic rats

    Science.gov (United States)

    Fallahnezhad, Somaye; Piryaei, Abbas; Tabeie, Faraj; Nazarian, Hamid; Darbandi, Hasan; Amini, Abdoldllah; Mostafavinia, Ataroalsadat; Ghorishi, Seyed Kamran; Jalalifirouzkouhi, Ali; Bayat, Mohammad

    2016-09-01

    The purpose of this study was to evaluate the influences of helium-neon (He-Ne) and infrared (IR) lasers on the viability and proliferation rate of healthy and ovariectomy-induced osteoporotic (OVX) bone marrow mesenchymal stem cells (BMMSCs) in vitro. MSCs harvested from the BM of healthy and OVX rats were culture expanded. He-Ne and IR lasers were applied three times at energy densities of 0.6, 1.2, and 2.4 J/cm2 for BMMSCs. BMMSCs viability and proliferation rate were evaluated by MTT assay on days 2, 4, 6, 14, and 21. The results showed that healthy BMMSCs responded optimally to 0.6 J/cm2 using an IR laser after three times of laser radiation. Moreover, it was found that OVX-BMMSCs responded optimally to 0.6 J/cm2 with He-Ne laser and one-time laser radiation. It is concluded that the low-level laser therapy (LLLT) effect depends on the physiological state of the BMMSCs, type of the laser, wavelength, and number of laser sessions. The biostimulation efficiency of LLLT also depends on the delivered energy density. LLLT can enhance the viability and proliferation rate of healthy and especially osteoporotic autologous BMMSCs, which could be very useful in regenerative medicine.

  11. Effect of single-dose low-level helium-neon laser irradiation on orthodontic pain: a split-mouth single-blind placebo-controlled randomized clinical trial

    OpenAIRE

    Sobouti, Farhad; Khatami, Maziar; Chiniforush, Nasim; Rakhshan, Vahid; Shariati, Mahsa

    2015-01-01

    Background Pain is the most common complication of orthodontic treatment. Low-level laser therapy (LLLT) has been suggested as a new analgesic treatment free of the adverse effects of analgesic medications. However, it is not studied thoroughly, and the available studies are quite controversial. Moreover, helium neon (He-Ne) laser has not been assessed before. Methods This split-mouth placebo-controlled randomized clinical trial was performed on 16 male and 14 female orthodontic patients requ...

  12. Formation of long-lived reactive species of blood serum proteins induced by low-intensity irradiation of helium-neon laser and their involvement in the generation of reactive oxygen species.

    Science.gov (United States)

    Ivanov, Vladimir E; Usacheva, Anna M; Chernikov, Anatoly V; Bruskov, Vadim I; Gudkov, Sergey V

    2017-11-01

    It was demonstrated that low-intensity radiation of helium-neon (He-Ne) laser at 632.8nm, which leads to the transition of oxygen to a singlet state, causes the formation of reactive oxygen species (ROS) - hydrogen peroxide, hydroxyl and superoxide (hydroperoxide) radicals - in aqueous solutions. The oxygen effect - dependence of hydrogen peroxide formation on the concentration of molecular oxygen - was shown, and the participation of singlet oxygen, hydroxyl radicals and superoxide (hydroperoxide) radicals in this process was testified. Laser radiation-induced ROS in solutions of blood serum proteins, bovine serum albumin and bovine gamma-globulin, cause the formation of long-lived reactive protein species (LRPS) with a half-life of about 4h. The generation of LRPS caused by laser irradiation results in prolonged several-hour generation of ROS - hydrogen peroxide, hydroxyl and superoxide radicals. As affected by LRPS, coupled radical reactions lead to conversion of dissolved molecular oxygen to hydrogen peroxide. Irradiation with light sources away from the oxygen absorption band is not attended by formation of ROS and LRPS. A consideration is provided for the possible molecular mechanisms of ROS formation under the influence of He-Ne laser irradiation, the role of proteins in their generation and the biological significance of these processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Effect of single-dose low-level helium-neon laser irradiation on orthodontic pain: a split-mouth single-blind placebo-controlled randomized clinical trial.

    Science.gov (United States)

    Sobouti, Farhad; Khatami, Maziar; Chiniforush, Nasim; Rakhshan, Vahid; Shariati, Mahsa

    2015-01-01

    Pain is the most common complication of orthodontic treatment. Low-level laser therapy (LLLT) has been suggested as a new analgesic treatment free of the adverse effects of analgesic medications. However, it is not studied thoroughly, and the available studies are quite controversial. Moreover, helium neon (He-Ne) laser has not been assessed before. This split-mouth placebo-controlled randomized clinical trial was performed on 16 male and 14 female orthodontic patients requiring bilateral upper canine retraction. The study was performed at a private clinic in Sari, Iran, in 2014. It was single blind: patients, orthodontist, and personnel were blinded of the allocations, but the laser operator (periodontist) was not blinded. Once canine retractor was activated, a randomly selected maxillary quarter received a single dose of He-Ne laser irradiation (632.8 nm, 10 mw, 6 j/cm(2) density). The other quarter served as the placebo side, treated by the same device but powered off. In the first, second, fourth, and seventh days, blinded patients rated their pain sensed on each side at home using visual analog scale (VAS) questionnaires. There was no harm identified during or after the study. Pain changes were analyzed using two- and one-way repeated-measures ANOVA, Bonferroni, and t-test (α = 0.01, β > 0.99). This trial was not registered. It was self-funded by the authors. Sixteen males and 11 females remained in the study (aged 12-21). Average pain scores sensed in all 4 intervals on control and laser sides were 4.06 ± 2.85 and 2.35 ± 1.77, respectively (t-test P laser therapy might reduce orthodontic pain caused by retracting maxillary canines.

  14. Photo-stimulatory effect of low energy helium-neon laser irradiation on excisional diabetic wound healing dynamics in wistar rats

    Directory of Open Access Journals (Sweden)

    Maiya Arun

    2009-01-01

    Full Text Available Background: Generally, the significances of laser photo stimulation are now accepted, but the laser light facilitates wound healing and tissue repair remains poorly understood. Aims: We have examined the hypothesis that the laser photo stimulation can enhance the collagen production in diabetic wounds using the excision wound model in the Wistar rat model. Methods: The circular wounds were created on the dorsum of the back of the animals. The animals were divided into two groups. The study group (N = 24 wound was treated with 632.8 nm He-Ne laser at a dose of 3-9J/cm 2 for 5 days a week until the wounds healed completely. The control group was sham irradiated. Result: A significant increase in the hydroxyproline content and reduction in the wound size were observed in the study group. The pro-healing actions seem to be due to increased collagen deposition as well as better alignment and maturation. Conclusion: The biochemical analysis and clinical observation suggested that 3-6 J/cm 2 laser photo stimulation facilitates the tissue repair process by accelerating collagen production in diabetic wound healing.

  15. Láser helio-neón combinado con clorhexidina al 0,2 %.: Efectos clínicos y microbiológicos en el tratamiento de la gingivitis crónica Helium-neon laser combined with 0.2% chlorhexidine: Clinical and microbiological effects in the treatment of chronic gingivitis.

    Directory of Open Access Journals (Sweden)

    Tatiana Peña Ruiz

    2007-09-01

    Full Text Available La gingivitis crónica constituye una de las formas más frecuentes de enfermedad periodontal, caracterizada por la inflamación crónica de la encías, tumefacción, enrojecimiento y sangramiento. Su principal factor de riesgo lo constituye la microbiota del surco gingival, que resulta necesario, pero no suficiente para desencadenarla. Se realizó un ensayo clínico-terapéutico fase II, controlado, aleatorizado y a simple ciegas, para evaluar los efectos clínicos y microbiológicos del tratamiento combinado de la radiación láser helio-neón (He-Ne con la clorhexidina al 0,2 %. Todos los pacientes recibieron tratamiento inicial; al mes de finalizado este, se distribuyeron aleatoriamente en 2 grupos: un grupo estudio que recibió la combinación láser-neón y clorhexidina al 0,2 % y otro grupo control que solo recibió clorhexidina al 0,2 %. Se realizó una evaluación a los 15, 30 y 45 días, con criterios de eficacia clínicos y microbiológicos. Los resultados clínicos fueron satisfactorios en el grupo estudio con predominio de los morfotipos I, caracterizados por cocos gramnegativos y positivos, compatibles con un periodonto sano. Los eventos adversos detectados con esta terapéutica fueron mínimos, todos relacionados con la somnolencia.Chronic gingivitis is one of the most common periodontal diseases that is characterized by chronic inflammation, tumefaction, redness and bleeding. The main risk factor is gingival sulcus microbiota that is essential but not enough to unleash it. A phase II controlled randomized blind clinical/therapeutical assay was conducted to evaluate the clinical and microbiological effects of the combined treatment based on helium-neon laser (He-Ne with 0.2% chlorhexidine. All the patients were initially treated; after a month, they were randomly distributed into two groups, that is, the study group received a helium-neon laser plus 0.2% chlorhexidine combination and the control group was treated with 0

  16. A linewidth-narrowed and frequency-stabilized dye laser for application in laser cooling of molecules.

    Science.gov (United States)

    Dai, D P; Xia, Y; Yin, Y N; Yang, X X; Fang, Y F; Li, X J; Yin, J P

    2014-11-17

    We demonstrate a robust and versatile solution for locking the continuous-wave dye laser for applications in laser cooling of molecules which need linewidth-narrowed and frequency-stabilized lasers. The dye laser is first stabilized with respect to a reference cavity by Pound-Drever-Hall (PDH) technique which results in a single frequency with the linewidth 200 kHz and short-term stabilization, by stabilizing the length of the reference cavity to a stabilized helium-neon laser we simultaneously transfer the ± 2 MHz absolute frequency stability of the helium-neon laser to the dye laser with long-term stabilization. This allows the dye laser to be frequency chirped with the maximum 60 GHz scan range while its frequency remains locked. It also offers the advantages of locking at arbitrary dye laser frequencies, having a larger locking capture range and frequency scanning range to be implemented via software. This laser has been developed for the purpose of laser cooling a molecular magnesium fluoride beam.

  17. Os efeitos do laser hélio-neônio de baixa intensidade na cicatrização de lesões cutâneas induzidas em ratos Effects of low-level helium-neon laser on induced wound healing in rats

    Directory of Open Access Journals (Sweden)

    Viviane L. Busnardo

    2010-02-01

    Full Text Available OBJETIVO: Avaliar os efeitos do laser de baixa potência hélio e neônio (HeNe na cicatrização de feridas cutâneas de ratos. MÉTODOS: Sessenta ratos Wistar foram divididos em grupos controle e experimento. Utilizou-se ferida incisional, longitudinal, dorso-mediana, suturada com pontos separados simples. No grupo experimento, as feridas foram irradiadas diariamente com aparelho de laser de HeNe com potência contínua máxima de 5mW, comprimento de onda de 632,8 nm, visível com densidade de energia de 4J/cm², área de raio do laser de 0,015cm², durante 36 segundos, em três pontos da lesão. As feridas foram avaliadas no 3º, no 7º e no 14º dia de pós-operatório. Cortes histológicos foram corados com hematoxilina-eosina (H&E e avaliados segundo protocolo de Vizzotto et al. (2003* para identificar o tipo de reação inflamatória e com Picrosirius para identificar os colágenos I e III e o índice de maturidade da cicatriz (IMaC. Utilizou-se imunoistoquímica com anti-CD45-LCA para o reconhecimento das células inflamatórias. RESULTADOS: Ambos os grupos mostraram o mesmo padrão inflamatório. No grupo experimento, observaram-se menos células inflamatórias nos três tempos estudados (pOBJECTIVE: To evaluate the effects of low-level helium-neon (HeNe laser on cutaneous wound healing in rats. METHODS: Sixty Wistar rats were divided into control group and experimental group. A sutured longitudinal, dorsal-medial incision was made, with simple separate stitches. The experimental group was irradiated daily in three areas of the wound with HeNe laser (5mW maximum continuous power, 632.8 nm wavelength, 4 J/cm² energy density and 0.015 cm² laser beam area for 36 seconds. The areas were evaluated on the third, seventh and fourteenth days postoperative. Histological sections were stained with hematoxylin-eosin to determine the type of inflammatory reaction according to the protocol by Vizzotto et al. (2003* and with Picrosirius to identify

  18. Helium Neon laser therapy for post mastectomy lymphedema and ...

    African Journals Online (AJOL)

    Mohamed M. Khalaf

    2012-12-08

    Dec 8, 2012 ... Institute who had modified radical mastectomy and had lymph- edema of the upper limb secondary to breast cancer surgery were included in the study. Their ages ranged from 45 to. 55 years. They were examined carefully by the physician before the study procedures. All patients were free from any other.

  19. Ab initio calculation of the interaction potentials of helium, neon, and methane as well as theoretical studies on their thermophysical properties and those of water vapor

    International Nuclear Information System (INIS)

    Hellmann, Robert

    2009-01-01

    Thermophysical properties of the pure gases helium, neon, methane and water vapor were calculated for low densities over wide temperature ranges. Statistical thermodynamics was used for the determination of the pressure virial coefficients. The kinetic theory of gases was utilized for the calculation of the transport and relaxation properties. So far kinetic theory was limited to linear molecules and has now been extended to molecules of arbitrary geometry to enable calculations on methane and water vapor. The interaction potentials, which are needed for all computations, were determined for helium, neon and methane from the supermolecular approach using quantum chemical ab initio methods. For water the interaction potentials were taken from the literature. The calculated values of the thermophysical properties for the four gases show very good agreement with the best experimental data. At very low and very high temperatures the theoretical values are more accurate than experimental data. (orig.)

  20. Ab initio calculation of the interaction potentials of helium, neon, and methane as well as theoretical studies on their thermophysical properties and those of water vapor; Ab initio-Berechnung der Wechselwirkungspotentiale von Helium, Neon und Methan sowie theoretische Untersuchungen zu ihren thermophysikalischen Eigenschaften und denen von Wasserdampf

    Energy Technology Data Exchange (ETDEWEB)

    Hellmann, Robert

    2009-06-16

    Thermophysical properties of the pure gases helium, neon, methane and water vapor were calculated for low densities over wide temperature ranges. Statistical thermodynamics was used for the determination of the pressure virial coefficients. The kinetic theory of gases was utilized for the calculation of the transport and relaxation properties. So far kinetic theory was limited to linear molecules and has now been extended to molecules of arbitrary geometry to enable calculations on methane and water vapor. The interaction potentials, which are needed for all computations, were determined for helium, neon and methane from the supermolecular approach using quantum chemical ab initio methods. For water the interaction potentials were taken from the literature. The calculated values of the thermophysical properties for the four gases show very good agreement with the best experimental data. At very low and very high temperatures the theoretical values are more accurate than experimental data. (orig.)

  1. Laser Stabilization with Laser Cooled Strontium

    DEFF Research Database (Denmark)

    Christensen, Bjarke Takashi Røjle

    the nonlinear effects from coupling of an optical cavity to laser cooled atoms having a narrow transition linewidth. Here, we have realized such a system where a thermal sample of laser cooled strontium-88 atoms are coupled to an optical cavity. The strontium-88 atoms were probed on the narrow 1S0-3P1 inter......-combination line at 689 nm in a strongly saturated regime. The dynamics of the atomic induced phase shift and absorption of the probe light were experimentally studied in details with the purpose of applications to laser stabilization. The atomic sample temperature was in the mK range which brought this system out....... The studies presented in this work open novel possibilities for alternative and simple strategies for surpassing the state-of-the-art laser stabilization and for realizing active light sources involving collective emission from narrow-line atoms....

  2. Polarization feedback laser stabilization

    Science.gov (United States)

    Esherick, P.; Owyoung, A.

    1987-09-28

    A system for locking two Nd:YAG laser oscillators includes an optical path for feeding the output of one laser into the other with different polarizations. Elliptical polarization is incorporated into the optical path so that the change in polarization that occurs when the frequencies coincide may be detected to provide a feedback signal to control one laser relative to the other. 4 figs.

  3. Molecular laser stabilization for LISA

    Science.gov (United States)

    Halloin, Hubert; Acef, Ouali; Argence, Berengere; Jeannin, Olivier; Prat, Pierre; de Vismes, Eden; Plagnol, Eric; Brillet, Alain; Mondin, Linda; Berthon, Jacques; Turazza, Oscar

    2017-11-01

    The expected performance of LISA relies on two main technical challenges: the ability for the spacecrafts to precisely follow the free-flying masses and the outstanding precision of the phase shift measurement. This latter constraint requires frequency stabilized lasers and efficient numerical algorithms to account for the redundant, delayed noise propagation, thus cancelling laser phase noise by many orders of magnitude (TDI methods). Recently involved in the technical developments for LISA, the goal of our team at APC (France) is to contribute on these two subjects: frequency reference for laser stabilization and benchtop simulation of the interferometer. In the present design of LISA, two stages of laser stabilization are used (not accounting for the "post-processed" TDI algorithm): laser pre-stabilization on a frequency reference and lock on the ultra stable distance between spacecrafts (arm-locking). While the foreseen (and deeply studied) laser reference consists of a Fabry-Perot cavity, other techniques may be suitable for LISA or future metrology missions. In particular, locking to a molecular reference (namely iodine in the case of the LISA Nd:YAG laser) is an interesting alternative. It offers the required performance with very good long-term stability (absolute frequency reference) though the reference can be slightly tuned to account for arm-locking. This technique is currently being investigated by our team and optimized for LISA (compactness, vacuum compatibility, ease of use and initialization, etc.). A collaboration with a French laboratory (the SYRTE) had been started aiming to study a second improved technique consisting in inserting the iodine cell in a Fabry-Perot cavity. Ongoing results and prospects to increase the performance of the system are presented in the present article.

  4. Low power laser irradiation does not affect the generation of signals in a sensory receptor

    Energy Technology Data Exchange (ETDEWEB)

    Lundeberg, T.; Zhou, J.

    1989-01-01

    The effect of low power Helium-Neon (He-Ne) and Gallium-Arsenide (Ga-As) laser on the slowly adapting crustacean stretch receptor was studied. The results showed that low power laser irradiation did not affect the membrane potential of the stretch receptor. These results are discussed in relation to the use of low power laser irradiation on the skin overlaying acupuncture points in treatment of pain syndrome.

  5. Laser treatment of otitis media in children

    Energy Technology Data Exchange (ETDEWEB)

    Podoynitsyna, L.F.

    1984-08-01

    Clinical trials were conducted with the helium-neon LG-75 laser (632.8 nm, 0.1 W/cm/sup 2/) in the management of 50 children with acute and chronic otitis media. The sessions consisted of 30 sec irradiation directed at the middle ear through the external meatus for a period of 5 days. Positive results were obtained in 45 of the patients with cessation of discharge on the 2nd or 3rd day, and return of hearing by the end of the week. The remission was not permanent in one patient with recurrent otitis media. These observations indicate that the anti-inflammatory effects of helium-neon irradiation constitute an effective treatment modality in children with otitis media. 6 references.

  6. Orthogonal polarization in lasers physical phenomena and engineering applications

    CERN Document Server

    Zhang, Shulian

    2013-01-01

    This practical book summarizes the latest research results of orthogonally polarized lasers, birefringence laser cavities, and their applications. Coverage ranges from basic principles and technologies to the characteristics of different cavities and lasers to various measurement techniques. A number of figures, experimental designs, and measurement curves are included, helping readers gain a thorough understanding of the many applications in modern engineering and start their own projects. Many types of relevant lasers (Helium/Neon lasers, Nd:YAG lasers, laser diodes, etc.) are also discussed

  7. Bibliography of Soviet Laser Developments, Number 76, March - April 1985.

    Science.gov (United States)

    1986-06-01

    Abramov , V.P.; Mazan’ko, I.P.1 Manoshkin, Yu.V.; Ulanov, Ye.A. ). Radial distribution of the gain in a helium-neon plasma at 0.63 um under a lateral...Samsonova, I.Ye.; Freyfert, K.M. (GOI). Study on optical stability of silicate fiber lightguides. OPMPA, no. 3, 1985, 9-10. 349. Abramov , A.A.; Borkina

  8. Semiconductor lasers stability, instability and chaos

    CERN Document Server

    Ohtsubo, Junji

    2017-01-01

    This book describes the fascinating recent advances made concerning the chaos, stability and instability of semiconductor lasers, and discusses their applications and future prospects in detail. It emphasizes the dynamics in semiconductor lasers by optical and electronic feedback, optical injection, and injection current modulation. Applications of semiconductor laser chaos, control and noise, and semiconductor lasers are also demonstrated. Semiconductor lasers with new structures, such as vertical-cavity surface-emitting lasers and broad-area semiconductor lasers, are intriguing and promising devices. Current topics include fast physical number generation using chaotic semiconductor lasers for secure communication, development of chaos, quantum-dot semiconductor lasers and quantum-cascade semiconductor lasers, and vertical-cavity surface-emitting lasers. This fourth edition has been significantly expanded to reflect the latest developments. The fundamental theory of laser chaos and the chaotic dynamics in se...

  9. GASP: A computer code for calculating the thermodynamic and transport properties for ten fluids: Parahydrogen, helium, neon, methane, nitrogen, carbon monoxide, oxygen, fluorine, argon, and carbon dioxide. [enthalpy, entropy, thermal conductivity, and specific heat

    Science.gov (United States)

    Hendricks, R. C.; Baron, A. K.; Peller, I. C.

    1975-01-01

    A FORTRAN IV subprogram called GASP is discussed which calculates the thermodynamic and transport properties for 10 pure fluids: parahydrogen, helium, neon, methane, nitrogen, carbon monoxide, oxygen, fluorine, argon, and carbon dioxide. The pressure range is generally from 0.1 to 400 atmospheres (to 100 atm for helium and to 1000 atm for hydrogen). The temperature ranges are from the triple point to 300 K for neon; to 500 K for carbon monoxide, oxygen, and fluorine; to 600 K for methane and nitrogen; to 1000 K for argon and carbon dioxide; to 2000 K for hydrogen; and from 6 to 500 K for helium. GASP accepts any two of pressure, temperature and density as input conditions along with pressure, and either entropy or enthalpy. The properties available in any combination as output include temperature, density, pressure, entropy, enthalpy, specific heats, sonic velocity, viscosity, thermal conductivity, and surface tension. The subprogram design is modular so that the user can choose only those subroutines necessary to the calculations.

  10. Laser oscillator with a wavelength stabilizing device

    International Nuclear Information System (INIS)

    Terada, T.; Yamaguchi, I.

    1975-01-01

    The laser tube constantly maintains a desired uniform wavelength of the laser beam. At least one of the two mirror members of the laser tube is movable, and is coupled magnetically with an electromagnetic stabilizing mechanism. The magnetic power of the electromagnetic mechanism is adjustable so that the distance between the two mirror members can be maintained constant irrespective of temperature changes and the like. As a result, a laser beam having a constant desired uniform wavelength is obtained. (auth)

  11. Semiconductor Lasers Stability, Instability and Chaos

    CERN Document Server

    Ohtsubo, Junji

    2013-01-01

    This third edition of “Semiconductor Lasers, Stability, Instability and Chaos” was significantly extended.  In the previous edition, the dynamics and characteristics of chaos in semiconductor lasers after the introduction of the fundamental theory of laser chaos and chaotic dynamics induced by self-optical feedback and optical injection was discussed. Semiconductor lasers with new device structures, such as vertical-cavity surface-emitting lasers and broad-area semiconductor lasers, are interesting devices from the viewpoint of chaotic dynamics since they essentially involve chaotic dynamics even in their free-running oscillations. These topics are also treated with respect to the new developments in the current edition. Also the control of such instabilities and chaos control are critical issues for applications. Another interesting and important issue of semiconductor laser chaos in this third edition is chaos synchronization between two lasers and the application to optical secure communication. One o...

  12. Semiconductor Lasers Stability, Instability and Chaos

    CERN Document Server

    Ohtsubo, Junji

    2008-01-01

    This monograph describes fascinating recent progress in the field of chaos, stability and instability of semiconductor lasers. Applications and future prospects are discussed in detail. The book emphasizes the various dynamics induced in semiconductor lasers by optical and electronic feedback, optical injection, and injection current modulation. Recent results of both theoretical and experimental investigations are presented. Demonstrating applications of semiconductor laser chaos, control and noise, Semiconductor Lasers describes suppression and chaotic secure communications. For those who are interested in optics but not familiar with nonlinear systems, a brief introduction to chaos analysis is presented.

  13. Low power lasers on genomic stability.

    Science.gov (United States)

    Trajano, Larissa Alexsandra da Silva Neto; Sergio, Luiz Philippe da Silva; Stumbo, Ana Carolina; Mencalha, Andre Luiz; Fonseca, Adenilson de Souza da

    2018-03-01

    Exposure of cells to genotoxic agents causes modifications in DNA, resulting to alterations in the genome. To reduce genomic instability, cells have DNA damage responses in which DNA repair proteins remove these lesions. Excessive free radicals cause DNA damages, repaired by base excision repair and nucleotide excision repair pathways. When non-oxidative lesions occur, genomic stability is maintained through checkpoints in which the cell cycle stops and DNA repair occurs. Telomere shortening is related to the development of various diseases, such as cancer. Low power lasers are used for treatment of a number of diseases, but they are also suggested to cause DNA damages at sub-lethal levels and alter transcript levels from DNA repair genes. This review focuses on genomic and telomere stabilization modulation as possible targets to improve therapeutic protocols based on low power lasers. Several studies have been carried out to evaluate the laser-induced effects on genome and telomere stabilization suggesting that exposure to these lasers modulates DNA repair mechanisms, telomere maintenance and genomic stabilization. Although the mechanisms are not well understood yet, low power lasers could be effective against DNA harmful agents by induction of DNA repair mechanisms and modulation of telomere maintenance and genomic stability. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Power stabilized CO2 gas transport laser

    International Nuclear Information System (INIS)

    Foster, J.D.; Kirk, R.F.; Moreno, F.E.; Ahmed, S.A.

    1975-01-01

    The output power of a high power (1 kW or more) CO 2 gas transport laser is stabilized by flowing the gas mixture over copper plated baffles in the gas channel during operation of the laser. Several other metals may be used instead of copper, for example, nickel, manganese, palladium, platinum, silver and gold. The presence of copper in the laser gas circuit stabilizes output power by what is believed to be a compensation of the chemical changes in the gas due to the cracking action of the electrical discharge which has the effect of diminishing the capactiy of the carbon dioxide gas mixture to maintain the rated power output of the laser. (U.S.)

  15. Robust laser frequency stabilization by serrodyne modulation.

    Science.gov (United States)

    Kohlhaas, Ralf; Vanderbruggen, Thomas; Bernon, Simon; Bertoldi, Andrea; Landragin, Arnaud; Bouyer, Philippe

    2012-03-15

    We report the relative frequency stabilization of a distributed feedback erbium-doped fiber laser on an optical cavity by serrodyne frequency shifting. A correction bandwidth of 2.3 MHz and a dynamic range of 220 MHz are achieved, which leads to a strong robustness against large disturbances up to high frequencies. We demonstrate that serrodyne frequency shifting reaches a higher correction bandwidth and lower relative frequency noise level compared to a standard acousto-optical modulator based scheme. Our results allow us to consider promising applications in the absolute frequency stabilization of lasers on optical cavities.

  16. Stabilized lasers for advanced gravitational wave detectors

    International Nuclear Information System (INIS)

    Willke, B; Danzmann, K; Kwee, P; Seifert, F; Frede, M; Kracht, D; Puncken, O; Schulz, B; Veltkamp, C; Wagner, S; Wessels, P; Winkelmann, L; King, P; Savage, R L Jr

    2008-01-01

    Second generation gravitational wave detectors require high power lasers with more than 100 W of output power and with very low temporal and spatial fluctuations. To achieve the demanding stability levels required, low noise techniques and adequate control actuators have to be part of the high power laser design. In addition feedback control and passive noise filtering is used to reduce the fluctuations in the so-called prestabilized laser system (PSL). In this paper, we discuss the design of a 200 W PSL which is under development for the Advanced LIGO gravitational wave detector and will present the first results. The PSL noise requirements for advanced gravitational wave detectors will be discussed in general and the stabilization scheme proposed for the Advanced LIGO PSL will be described

  17. Towards a solid-state ring laser gyroscope

    Science.gov (United States)

    El Badaoui, Noad; Morbieu, Bertrand; Martin, Philippe; Rouchon, Pierre; Pocholle, Jean-Paul; Gutty, François; Feugnet, Gilles; Schwartz, Sylvain

    2014-12-01

    In this paper, we report our recent progress towards a solid-state ring laser gyroscope (RLG), where mode competition is circumvented by active control of differential losses, and nonlinear effects are mitigated by longitudinal vibration of the gain medium. The resulting dynamics is significantly different from that of a classical helium-neon RLG, owing in particular to parametric resonances that occur when the Sagnac frequency is an integer multiple of the crystal vibration frequency. We describe the main experimental and theoretical results obtained so far, and the prospects of practical applications in the near future. xml:lang="fr"

  18. State of some peripheral organs during laser puncture correction of ovarian functional deficiency

    Science.gov (United States)

    Vylegzhanina, T. A.; Kuznetsova, Tatiana I.; Maneeva, O.; Ryzhkovskaya, E. L.; Yemelianova, A.

    2001-01-01

    The findings from studies on structural and functional parameters of the adrenal, thyroid, and pineal glands in conditions of ovarian hypofunction and after its correction by laser puncture are presented. An experimentally induced hypofunction of the ovaries was shown to be accompanied by a decreased hormonal synthesis in the cortical fascicular zone. The epiphysis showed ultra structural signs of increased functional activity. Application of a helium-neon laser to biologically active points of the ovarian reflexogenic zone induced normalization of the ovarian cycle, potentiating of the adrenal functional state, and a decreased thyroid hormone production and abolished the activatory effect of the dark regime on the functional state of the pineal gland.

  19. Frequency-comb-referenced tunable diode laser spectroscopy and laser stabilization applied to laser cooling.

    Science.gov (United States)

    Fordell, Thomas; Wallin, Anders E; Lindvall, Thomas; Vainio, Markku; Merimaa, Mikko

    2014-11-01

    Laser cooling of trapped atoms and ions in optical clocks demands stable light sources with precisely known absolute frequencies. Since a frequency comb is a vital part of any optical clock, the comb lines can be used for stabilizing tunable, user-friendly diode lasers. Here, a light source for laser cooling of trapped strontium ions is described. The megahertz-level stability and absolute frequency required are realized by stabilizing a distributed-feedback semiconductor laser to a frequency comb. Simple electronics is used to lock and scan the laser across the comb lines, and comb mode number ambiguities are resolved by using a separate, saturated absorption cell that exhibits easily distinguishable hyperfine absorption lines with known frequencies. Due to the simplicity, speed, and wide tuning range it offers, the employed technique could find wider use in precision spectroscopy.

  20. Atomic stabilization in superintense laser fields

    International Nuclear Information System (INIS)

    Gavrila, Mihai

    2002-01-01

    Atomic stabilization is a highlight of superintense laser-atom physics. A wealth of information has been gathered on it; established physical concepts have been revised in the process; points of contention have been debated. Recent technological breakthroughs are opening exciting perspectives of experimental study. With this in mind, we present a comprehensive overview of the phenomenon. We discuss the two forms of atomic stabilization identified theoretically. The first one, 'quasistationary (adiabatic) stabilization' (QS), refers to the limiting case of plane-wave monochromatic radiation. QS characterizes the fact that ionization rates, as calculated from single-state Floquet theory, decrease with intensity (possibly in an oscillatory manner) at high values of the field. We present predictions for QS from various forms of Floquet theory: high frequency (that has led to its discovery and offers the best physical insight), complex scaling, Sturmian, radiative close coupling and R-matrix. These predictions all agree quantitatively, and high-accuracy numerical results have been obtained for hydrogen. Predictions from non-Floquet theories are also discussed. Thereafter, we analyse the physical origin of QS. The alternative form of stabilization, 'dynamic stabilization' (DS), is presented next. This expresses the fact that the ionization probability at the end of a laser pulse of fixed shape and duration does not approach unity as the peak intensity is increased, but either starts decreasing with the intensity (possibly in an oscillatory manner), or flattens out at a value smaller than unity. We review the extensive research done on one-dimensional models, that has provided valuable insights into the phenomenon; two- and three-dimensional models are also considered. Full three-dimensional Coulomb calculations have encountered severe numerical handicaps in the past, and it is only recently that a comprehensive mapping of DS could be made for hydrogen. An adiabatic

  1. A transportable methane stabilized He-Ne laser

    Science.gov (United States)

    Akimoto, Yoshiaki

    1987-06-01

    The performance of a transportable methane stabilized He-Ne laser system, developed for a wavelength-optical frequency standard according to the 1983 Comite Consultatif pour la Definition du Metier, is discussed. An offset-locked laser system using a phase comparison technique is described which is used to evaluate the stabilized laser system. A frequency stability of 2.5 x 10 to the -12th tau exp -1/2, and a resettability of 1 x 10 to the -11th, are estimated for the stabilized laser system.

  2. Laser signals' nonlinear change in fatty acids

    CERN Document Server

    Ghelmez-Dumitru, M; Piscureanu, M; Sterian, A

    2003-01-01

    Previous works showed that thin layers of fatty acids and fatty acid-cholesterol mixtures behaved as optical liquid crystals, even at low incident laser power. The paper presents an experimental and computer study of laser signals, emergent from such samples, in presence of fluctuations. The optical emergent laser beams' features at different incident parameters were experimentally determined for different type (c.w. and pulsed) lasers, as for example helium-neon and Nd sup 3 sup + glass lasers. The results were correlated with the amount of cholesterol in mixtures and with their response in external electric field. These measurements are in all cases affected by fluctuations. We developed some computer-based procedures, by using the TableCurve3D from Jandel Scientific software and equations Runge-Kutta in MATLAB for taking into account these fluctuations.

  3. Laser frequency stabilization and large detuning by Doppler-free ...

    Indian Academy of Sciences (India)

    We present results of a study of frequency stabilization of a diode laser ( = 780 nm) using the Doppler-free dichroic lock (DFDL) technique and its use for laser cooling of atoms. Quantitative measurements of frequency stability were performed and the Allan variance was found to be 6.9 × 10−11 for an averaging time of 10 ...

  4. Fully digital frequency stabilization of IR fiber-coupled laser

    Czech Academy of Sciences Publication Activity Database

    Jedlička, Petr; Lazar, Josef; Číp, Ondřej

    2006-01-01

    Roč. 77, č. 6 (2006), 063111:1-5 ISSN 0034-6748 R&D Projects: GA AV ČR IAA200650504; GA MŠk(CZ) LC06007 Institutional research plan: CEZ:AV0Z20650511 Keywords : DFB laser * laser stabilization * dissociated iodine * linear absorption Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.541, year: 2006

  5. Laser scanning of experimental solar cells

    Science.gov (United States)

    Plunkett, B. C.; Lasswell, P. G.

    1980-01-01

    A description is presented of a laser scanning instrument which makes it possible to display and measure the spatial response of a solar cell. Examples are presented to illustrate the use of generated micrographs in the isolation of flaws and features of the cell. The laser scanner system uses a 4 mW, CW helium-neon laser, operating a wavelength of 0.633 micrometers. The beam is deflected by two mirror galvanometers arranged to scan in orthogonal directions. After being focused on the solar cell by the beam focusing lens, the moving light spot raster scans the specimen. The current output of the photovoltaic device under test, as a function of the scan dot position, can be displayed in several modes. The laser scanner has proved to be a very useful diagnostic tool in optimizing the process design of transparent metal film photovoltaic devices on Zn3P2, a relatively new photovoltaic material.

  6. Laser puncture therapy of nervous system disorders

    Energy Technology Data Exchange (ETDEWEB)

    Anishchenko, G.; Kochetkov, V.

    1984-08-29

    The authors discuss experience with treatment of nervous system disorders by means of laser-puncture therapy. Commenting on the background of the selection of this type of treatment, they explain that once researchers determined the biological action of laser light on specific nerve receptors of the skin, development of laser apparatus capable of concentrating the beam in the millimeter band was undertaken. The devices that are being used for laser-puncture are said to operate in the red helium-neon band of light. The authors identify beam parameters that have been selected for different groups of acupuncture points of the skin, and the courses of treatment (in seconds of radiation) and their time intervals. They go on to discuss the results of treatment of over 800 patients categorized in a group with disorders of the peripheral nervous system and a second group with disorders of the central nervous system.

  7. Active stabilization of a diode laser injection lock.

    Science.gov (United States)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-06-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  8. A High Reliability Frequency Stabilized Semiconductor Laser Source Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs high stability laser source of 1W output power for Lidar applications. Princeton Optronics has developed ultra-stable, narrow linewidth diode pumped solid...

  9. Simplified laser frequency stabilization using spatial-mode interference

    Data.gov (United States)

    National Aeronautics and Space Administration — We will demonstrate a laser frequency stabilization technique based on spatial-mode interference that promises reductions in complexity, mass and power consumption...

  10. Iodine Stabilized Seed Laser for Space Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of this SBIR effort is development of a space qualifiable, compact, frequency stabilized seed laser with low SWaP for routine use in NASA LaRC's...

  11. Laser amplitude stabilization for advanced interferometric gravitational wave detectors

    International Nuclear Information System (INIS)

    Barr, B W; Strain, K A; Killow, C J

    2005-01-01

    We present results of experiments into the stabilization of the amplitude of Nd:YAG lasers for use in advanced gravitational wave detectors. By feeding back directly to the pump-diode driving current we achieved shot-noise-limited stabilization at frequencies up to several kHz with some residual noise at lower frequencies (sub ∼100 Hz). The method used is applicable to higher powered laser systems planned for advanced interferometric gravitational wave detectors

  12. Laser frequency stabilization and large detuning by Doppler-free ...

    Indian Academy of Sciences (India)

    method for frequency stabilization of these lasers is based on saturated absorption spectroscopy (SAS) [3]. The laser frequency is locked either at the center or at the side of a narrow peak in the Doppler-free high-resolution saturated absorp- tion spectrum of the atom. Locking at the side of the peak is straightforward and.

  13. Stabilized High Power Laser for Advanced Gravitational Wave Detectors

    International Nuclear Information System (INIS)

    Willke, B; Danzmann, K; Fallnich, C; Frede, M; Heurs, M; King, P; Kracht, D; Kwee, P; Savage, R; Seifert, F; Wilhelm, R

    2006-01-01

    Second generation gravitational wave detectors require high power lasers with several 100W of output power and with very low temporal and spatial fluctuations. In this paper we discuss possible setups to achieve high laser power and describe a 200W prestabilized laser system (PSL). The PSL noise requirements for advanced gravitational wave detectors will be discussed in general and the stabilization scheme proposed for the Advanced LIGO PSL will be described. Special emphasis will be given to the most demanding power stabilization requirements and new results (RIN ≤ 4x10 -9 /√Hz) will be presented

  14. Mathematical modelling and linear stability analysis of laser fusion cutting

    International Nuclear Information System (INIS)

    Hermanns, Torsten; Schulz, Wolfgang; Vossen, Georg; Thombansen, Ulrich

    2016-01-01

    A model for laser fusion cutting is presented and investigated by linear stability analysis in order to study the tendency for dynamic behavior and subsequent ripple formation. The result is a so called stability function that describes the correlation of the setting values of the process and the process’ amount of dynamic behavior.

  15. Active stabilization of a diode laser injection lock

    Energy Technology Data Exchange (ETDEWEB)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep [Department of Physics, University of Washington, P.O. Box 351560, Seattle, Washington 98195-1560 (United States)

    2016-06-15

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  16. Investigation of frequency stability and design criteria of ring lasers

    DEFF Research Database (Denmark)

    Pedersen, Christian; Lichtenberg Hansen, P.; Buchhave, Preben

    1996-01-01

    We present a comprehensive Jones matrix analysis of two commonly used ring laser resonators. Different aspects on how to obtain low loss eigenmodes and/or high loss difference between the two directions of the cavity, and thus high frequency stability, are investigated. Also different approximati...... approximations are evaluated. Since the theory has been kept general, the derived results can be applied to a large class of ring laser designs. Finally the influence of backscattered light on the stability is considered. Experimental results on two ring lasers are discussed.......We present a comprehensive Jones matrix analysis of two commonly used ring laser resonators. Different aspects on how to obtain low loss eigenmodes and/or high loss difference between the two directions of the cavity, and thus high frequency stability, are investigated. Also different...

  17. Active stabilization of a diode laser injection lock

    International Nuclear Information System (INIS)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  18. Laser frequency stabilization and shifting by using modulation transfer spectroscopy

    Science.gov (United States)

    Cheng, Bing; Wang, Zhao-Ying; Wu, Bin; Xu, Ao-Peng; Wang, Qi-Yu; Xu, Yun-Fei; Lin, Qiang

    2014-10-01

    The stabilizing and shifting of laser frequency are very important for the interaction between the laser and atoms. The modulation transfer spectroscopy for the 87Rb atom with D2 line transition F = 2 → F' = 3 is used for stabilizing and shifting the frequency of the external cavity grating feedback diode laser. The resonant phase modulator with electro—optical effect is used to generate frequency sideband to lock the laser frequency. In the locking scheme, circularly polarized pump- and probe-beams are used. By optimizing the temperature of the vapor, the pump- and probe-beam intensity, the laser linewidth of 280 kHz is obtained. Furthermore, the magnetic field generated by a solenoid is added into the system. Therefore the system can achieve the frequency locking at any point in a range of hundreds of megahertz frequency shifting with very low power loss.

  19. Wavelength stabilized multi-kW diode laser systems

    Science.gov (United States)

    Köhler, Bernd; Unger, Andreas; Kindervater, Tobias; Drovs, Simon; Wolf, Paul; Hubrich, Ralf; Beczkowiak, Anna; Auch, Stefan; Müntz, Holger; Biesenbach, Jens

    2015-03-01

    We report on wavelength stabilized high-power diode laser systems with enhanced spectral brightness by means of Volume Holographic Gratings. High-power diode laser modules typically have a relatively broad spectral width of about 3 to 6 nm. In addition the center wavelength shifts by changing the temperature and the driving current, which is obstructive for pumping applications with small absorption bandwidths. Wavelength stabilization of high-power diode laser systems is an important method to increase the efficiency of diode pumped solid-state lasers. It also enables power scaling by dense wavelength multiplexing. To ensure a wide locking range and efficient wavelength stabilization the parameters of the Volume Holographic Grating and the parameters of the diode laser bar have to be adapted carefully. Important parameters are the reflectivity of the Volume Holographic Grating, the reflectivity of the diode laser bar as well as its angular and spectral emission characteristics. In this paper we present detailed data on wavelength stabilized diode laser systems with and without fiber coupling in the spectral range from 634 nm up to 1533 nm. The maximum output power of 2.7 kW was measured for a fiber coupled system (1000 μm, NA 0.22), which was stabilized at a wavelength of 969 nm with a spectral width of only 0.6 nm (90% value). Another example is a narrow line-width diode laser stack, which was stabilized at a wavelength of 1533 nm with a spectral bandwidth below 1 nm and an output power of 835 W.

  20. FROM THE HISTORY OF LASER CREATION

    Directory of Open Access Journals (Sweden)

    I.M. Belousova

    2014-03-01

    Full Text Available The paper briefly describes the history of formation of a new science direction - quantum electronics, associated with the discovery of masers and lasers by scientists from the USA (Ch. Townes and the USSR (N.G. Basov and A. M. Prokhorov. The world's first ruby laser designed by T. Maiman is described. Some historical events devoted to creation and research of lasers are given in which the author of the paper as well as research workers from Vavilov State Optical Institute, ITMO University and LOMO have taken direct part in the development of solid-state and gas lasers (helium-neon, photodissociation, CO2-lasers and laser optical systems. Contribution of researchers from Vavilov State Optical Institute, LOMO and ITMO University to large-scale programs on development of lasers for laser nuclear fusion, laser weapons and “Phobos” program is shown. The paper deals in brief with new issues of development and application of lasers, mainly, within the project of laser orbital space station of the future, for the conversion of solar energy into laser radiation. Description of idea of solar energy transformation by fullerene-oxygen laser is presented. The patent for it has been taken out by Vavilov State Optical Institute. Developed fullerene-oxygen-iodine laser and laser structure models for industrial applications and solar energy conversion into laser radiation are described. Parameters for hypothetical laser-optical system of the future space station are given.

  1. Method of stabilizing a laser apparatus with wavelength converter

    DEFF Research Database (Denmark)

    2013-01-01

    A method of controlling beam quality and stability of a laser apparatus, the laser apparatus comprising, a diode laser (10) providing first radiation of at least a first wavelength, and a frequency conversion unit (12) configured to frequency-convert the first radiation from the diode laser......) into the first section (222), a second contact (221) for injecting a second current (I2) into the second section (223), and means for controlling a temperature of the diode laser; wherein the method comprises monitoring a first parameter indicative of the power content of a dominant lobe of the first radiation...... and to output the frequency-converted radiation (213), the frequency-converted radiation having at least a second wavelength different from the first wavelength, the diode laser (10) comprising at least a first and a second section (222,223), a first contact (220) for injecting a first current (I1...

  2. Solid-state ring laser gyro for aerospace applications

    Science.gov (United States)

    Schwartz, Sylvain; Gutty, François; Feugnet, Gilles; Pocholle, Jean-Paul; Desilles, Gaël.

    2017-11-01

    We report on the development of a prototype solidstate ring laser gyro based on a diode-pumped neodymium-doped yttrium aluminum garnet crystal as the gain medium. We describe in this paper how we circumvent mode competition between the counter-propagating modes using a feedback loop acting on the differential losses. We then show how the non-linear frequency response can be significantly improved by vibrating the gain medium along the laser axis, leading to a behavior similar as a typical Helium-Neon ring laser gyro. We finally discuss the undergoing improvements for achieving high inertial performance with this device, with significant potential benefits in terms of cost and robustness as compared to other highperformance gyro technologies.

  3. Programmable current source for diode lasers stabilized optical fiber

    International Nuclear Information System (INIS)

    Gomez, J.; Camas, J.; Garcia, L.

    2012-01-01

    In this paper, we present the electronic design of a programmable stabilized current source. User can access to the source through a password, which, it has a database with the current and voltage operating points. This source was successfully used as current source in laser diode in optical fiber sensors. Variations in the laser current were carried out by a monitoring system and a control of the Direct Current (DC), which flowing through a How land source with amplifier. The laser current can be stabilized with an error percent of ± 1 μA from the threshold current (Ith) to its maximum operation current (Imax) in DC mode. The proposed design is reliable, cheap, and its output signal of stabilized current has high quality. (Author)

  4. High stability lasers for lidar and remote sensing

    Science.gov (United States)

    Heine, Frank; Lange, Robert; Seel, Stefan; Smutny, Berry

    2017-11-01

    Tesat-Spacecom is currently building a set flight models of frequency stabilized lasers for the ESA Missions AEOLUS and LTP. Lasers with low intensity noise in the kHz region and analogue tuning capabilities for frequency and output power are developed for the on board metrology of the LTP project, the precursor mission for LISA. This type of laser is internally stabilized by precise temperature control, approaching an ALLAN variance of 10-9 for 100 sec. It can be easily locked to external frequency references with LIDAR) is used as the master frequency reference and is stabilized internally by a optical cavity. It shows a 3* 10-11 Allan variance from time intervals 1 sec - 1000 sec. Furthermore it is step-tunable for calibration of the receiver instrument with a speed of GHz / sec by a digital command interface. Performance and environmental test results will be presented.

  5. Active Stabilization of a Diode Laser Injection Lock

    OpenAIRE

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudde...

  6. A Laser Stabilization System for Rydberg Atom Physics

    Science.gov (United States)

    2015-09-06

    that is generated in a multi-pass frequency doubling cavity. In addition, the master laser wavelengths of 1020 nm and 960 nm lie in the near infra - red ...U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 laser stabilization, precision measurement REPORT DOCUMENTATION...Field Measurements Using Cs Rydberg Atoms in Vapor Cells,” H. Fan, S. Kumar and J.P. Shaffer, DAMOP, Columbus, OH (2015). “Interacting Rydberg Atoms

  7. Absolute frequency shifts of iodine cells for laser stabilization

    Czech Academy of Sciences Publication Activity Database

    Lazar, Josef; Hrabina, Jan; Jedlička, Petr; Číp, Ondřej

    2009-01-01

    Roč. 46, č. 5 (2009), s. 450-456 ISSN 0026-1394 R&D Projects: GA AV ČR IAA200650504; GA MŠk(CZ) LC06007; GA MŠk 2C06012; GA AV ČR KAN311610701; GA MPO 2A-1TP1/127; GA MPO FT-TA3/133 Institutional research plan: CEZ:AV0Z20650511 Keywords : laser stabilization * Nd :YAG laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.634, year: 2009

  8. High stability space frame for a large fusion laser

    International Nuclear Information System (INIS)

    Hurley, C.A.; Myall, J.O.

    1975-01-01

    The Shiva laser system is a large neodymium glass laser target irradiation facility being constructed at LLL to perform laser fusion experiments. A frame is being constructed to support the large number of laser components that make up the Shiva system. Twenty laser chains composed of amplifiers, spatial filters, polarizers, rotators, and mirrors will be arranged in an optimum geometry so that each beam arrives at the target simultaneously and within alignment tolerances. This frame is capable of supporting approximately 600 individual component assemblies and maintaining a tolerance of +-4-μrad rotation between any two points over a period of 100 s. Consideration has been given to the positional stability and support of the components, the geometrical array of stacked beams with respect to the oscillator and target, the flow of utilities (e.g., power cables and cooling gas pipes), good accessibility for operation and maintenance, and adaptability for change and growth

  9. Intensity and frequency stabilization of a laser diode by simultaneously controlling its temperature and current

    Science.gov (United States)

    Mu, Weiwei; Hu, Zhaohui; Wang, Jing; Zhou, Binquan

    2017-10-01

    Nuclear magnetic resonance gyroscope (NMRG) detects the angular velocity of the vehicle utilizing the interaction between the laser beam and the alkali metal atoms along with the noble gas atoms in the alkali vapor cell. In order to reach high precision inertial measurement target, semiconductor laser in NMRG should have good intensity and frequency stability. Generally, laser intensity and frequency are stabilized separately. In this paper, a new method to stabilize laser intensity and frequency simultaneously with double-loop feedback control is presented. Laser intensity is stabilized to the setpoint value by feedback control of laser diode's temperature. Laser frequency is stabilized to the Doppler absorption peak by feedback control of laser diode's current. The feedback control of current is a quick loop, hence the laser frequency stabilize quickly. The feedback control of temperature is a slow loop, hence the laser intensity stabilize slowly. With the feedback control of current and temperature, the laser intensity and frequency are stabilized finally. Additionally, the dependence of laser intensity and frequency on laser diode's current and temperature are analyzed, which contributes to choose suitable operating range for the laser diode. The advantage of our method is that the alkali vapor cell used for stabilizing laser frequency is the same one as the cell used for NMRG to operate, which helps to miniaturize the size of NMRG prototype. In an 8-hour continuous measurement, the long-term stability of laser intensity and frequency increased by two orders of magnitude and one order of magnitude respectively.

  10. Laser biostimulation (Ne-He and Ga-As) effects as compared to the conventional therapy in several pelvic inflammatory diseases

    Science.gov (United States)

    Antipa, Ciprian; Dona, Dumitru; Podoleanu, Adrian Gh.; Crisan, Nicolae; Constantinescu, Camelia

    1993-05-01

    We studied the effects of the very low-power Gallium-Arsenic infrared semiconductor laser and low-power Helium-Neon laser irradiation, single or in combination, compared to the placebo and conventional therapy on the recovery of 118 female patients from our hospital with the diagnosis of chronic pelvic inflammatory disorders. Laser biostimulation therapy proved to be significantly more efficient as compared with placebo or conventional therapy. The most efficient of all kinds of irradiations was the combination between He-Ne and Ga-As (laserpuncture and scanning). After laser treatments we didn't find any significant local genital changes both at the bimanual examination (except provoked pain), and at the echographical examination. Soft and very low-power laser therapy can be a useful alternative to the conventional treatments for pelvic inflammatory diseases.

  11. Laser frequency stabilization using linear magneto-optics

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Budker, Dmitry; Davis, John R.

    2000-01-01

    The design of a diode laser frequency stabilization system using the Zeeman effect is described. Various regimes of operation are analyzed using the Jones matrix approach. The system is different from the original Joint Institute for Laboratory Astrophysics design in that the magnetic fields are fully contained and thus it can be used in proximity of magnetically sensitive instruments. (c) 2000 American Institute of Physics

  12. Nanowire Lasers of Formamidinium Lead Halide Perovskites and Their Stabilized Alloys with Improved Stability.

    Science.gov (United States)

    Fu, Yongping; Zhu, Haiming; Schrader, Alex W; Liang, Dong; Ding, Qi; Joshi, Prakriti; Hwang, Leekyoung; Zhu, X-Y; Jin, Song

    2016-02-10

    The excellent intrinsic optoelectronic properties of methylammonium lead halide perovskites (MAPbX3, X = Br, I), such as high photoluminescence quantum efficiency, long carrier lifetime, and high gain coupled with the facile solution growth of nanowires make them promising new materials for ultralow-threshold nanowire lasers. However, their photo and thermal stabilities need to be improved for practical applications. Herein, we report a low-temperature solution growth of single crystal nanowires of formamidinium lead halide perovskites (FAPbX3) that feature red-shifted emission and better thermal stability compared to MAPbX3. We demonstrate optically pumped room-temperature near-infrared (∼820 nm) and green lasing (∼560 nm) from FAPbI3 (and MABr-stabilized FAPbI3) and FAPbBr3 nanowires with low lasing thresholds of several microjoules per square centimeter and high quality factors of about 1500-2300. More remarkably, the FAPbI3 and MABr-stabilized FAPbI3 nanowires display durable room-temperature lasing under ∼10(8) shots of sustained illumination of 402 nm pulsed laser excitation (150 fs, 250 kHz), substantially exceeding the stability of MAPbI3 (∼10(7) laser shots). We further demonstrate tunable nanowire lasers in wider wavelength region from FA-based lead halide perovskite alloys (FA,MA)PbI3 and (FA,MA)Pb(I,Br)3 through cation and anion substitutions. The results suggest that formamidinium lead halide perovskite nanostructures could be more promising and stable materials for the development of light-emitting diodes and continuous-wave lasers.

  13. Stabilization effect of Weibel modes in relativistic laser fusion plasma

    Energy Technology Data Exchange (ETDEWEB)

    Belghit, Slimen, E-mail: Belghit.slimen@gmail.com; Sid, Abdelaziz, E-mail: Sid-abdelaziz@hotmail.com [Laboratoire de Physique des rayonnements et de leurs interactions avec la matière (PRIMALAB), département de Physique, faculté des Sciences de la Matière, Université de Batna 1, 05000DZ, Batna (Algeria)

    2016-06-15

    In this work, the Weibel instability (WI) due to inverse bremsstrahlung (IB) absorption in a laser fusion plasma has been investigated. The stabilization effect due to the coupling of the self-generated magnetic field by WI with the laser wave field is explicitly shown. In this study, the relativistic effects are taken into account. Here, the basic equation is the relativistic Fokker-Planck (F-P) equation. The main obtained result is that the coupling of self-generated magnetic field with the laser wave causes a stabilizing effect of excited Weibel modes. We found a decrease in the spectral range of Weibel unstable modes. This decreasing is accompanied by a reduction of two orders in the growth rate of instable Weibel modes or even stabilization of these modes. It has been shown that the previous analysis of the Weibel instability due to IB has overestimated the values of the generated magnetic fields. Therefore, the generation of magnetic fields by the WI due to IB should not affect the experiences of an inertial confinement fusion.

  14. Laser stabilization with a frequency-to-voltage chip for narrow-line laser cooling.

    Science.gov (United States)

    McFerran, J J

    2018-04-01

    We use integrated circuit-based frequency-to-voltage conversion of a frequency comb beat signal as the means for laser frequency stabilization that is suitable for narrow-line laser cooling. The method is compared to an atomic beam lock where the laser frequency instability for the new scheme shows an improvement of 2 orders of magnitude at sub-1 s and grants a lock-capture range that is approximately 30 times greater. We employ the locking method on a 1111.6 nm laser that is frequency doubled and used in a dual-wavelength magneto-optical trap for Yb171 atoms, producing atomic cloud temperatures of ∼20  μK.

  15. Dither-free stabilization of CO2 lasers for far infrared pumping: A photoacoustic approach

    Science.gov (United States)

    Bennett, C. A., Jr.; Hutchinson, D. P.

    1986-02-01

    A method based on the photoacoustic technique is described for dither-free frequency stabilization of the optical pump in a CH3OH laser operating at 119 (MU)m. Heterodyne measurements on two independently locked far infrared radiation (FIR) lasers indicate excellent long term frequency and power stability. This stabilization scheme should be applicable to all optially pumped FIR lasants.

  16. Induratio penis plastica (IPP) and laser: a review

    Science.gov (United States)

    Longo, Leonardo; Mancini, S.; Postiglione, M. G.

    2002-10-01

    The first employments of Laser therapy for I.P.P. came from back to more than twenty years ago. At the beginning it was employed only in the acute forms as analgesic laser laser was used also as anti-inflammatory following the doses of Low Level Laser Therapy. Than the science tried to use the laser effect remodelling phase of the scars, to make the fibrosis regrade in the chronic forms. Tunable laser in small optical fiber was used for ablation of calcified zones with very good results. For the slight forms were used diode laser 660 and 904 nm, alone ir coupling with CO2 laser with large spot. At first some Author used helium-Neon laser 632. Some of these lasers were combined wtih microiontophoresis and ultrasounds therapy in teh same treatment. Now we use 810 nm surgical diode laser in almost all induratio forms. The immediate results and follow up will be discussed. Thanks to these results we could conclude that IPP laser therapy can be effective in most of the clinic forms. Although the used procedure is subject to improvement.

  17. Correction of biochemical and functional disorders in brain ischaemia with laser therapy

    Science.gov (United States)

    Musienko, Julia I.; Nechipurenko, Natalia I.; Vasilevskaya, Ludmila A.

    2005-08-01

    Application of intravenous laser irradiation of blood (ILIB) is considered to be the most effective method of laser therapy and its application is expedient pathogenetically in the ischemic disturbances. The aim of this study is to investigate ILIB influence with red helium-neon laser (HNL) with 630 nm wavelength and different powers on blood oxygen transport (BOT), cerebral and dermal microhaemodynamics (MGD), hydro-ion balance in normal rabbits and after modeling of local ischemia of brain (LIB). Experimental cerebral ischemia is characterized by development of BOT disturbance, ionic disbalance and edema in the ischemic brain region. Microcirculation disturbances with worsening of the cerebral and dermal MHD were revealed. ILIB with HNL radiation of 2.5 and 4.5 mW powers provokes dehydratation of brain structure alone with the K+, Na+ concentration decreasing and hemoglobin-oxygen affinity increasing in intact group of animals. There was not revealed marked changes of cerebral MHD condition here. Using of ILIB in rabbits after LIB contributes for improving function of BOT, normalizing of water content in all cerebral structures compared to operated animals. Preventive ILIB provoked improvement of speckl-optical parameters and marked protective effect on microhaemodynamics processes in superficial brain structures. HNL radiation with 1.0 mW power results in worsening of oxygen transport, cerebral and skin MHD, hydro-ion homeostasis in animals with LIB modeling. Thus, laser haemotherapy contributes for improving of hydro-ion status, blood oxygen transport and cerebral microcirculation in brain ischemia, what allows considering that helium-neon radiation with the pointed regimen is substantiated pathogenetically in brain ischaemia.

  18. Stability of a Light Sail Riding on a Laser Beam

    Energy Technology Data Exchange (ETDEWEB)

    Manchester, Zachary [John A. Paulson School of Engineering and Applied Science, Harvard University, 60 Oxford St., Cambridge, MA 02138 (United States); Loeb, Abraham, E-mail: zmanchester@seas.harvard.edu [Astronomy Department, Harvard University, 60 Garden St., Cambridge, MA 02138 (United States)

    2017-03-10

    The stability of a light sail riding on a laser beam is analyzed both analytically and numerically. Conical sails on Gaussian beams, which have been studied in the past, are shown to be unstable without active control or additional mechanical modifications. A new architecture for a passively stable sail-and-beam configuration is proposed. The novel spherical shell design for the sail is capable of “beam riding” without the need for active feedback control. Full three-dimensional ray-tracing simulations are performed to verify our analytical results.

  19. Endodontic applications of short pulsed FR Nd:YAG dental laser: treatment of dystrophic calcification: a clinical trial report

    Science.gov (United States)

    Gregg, Robert H., II

    1992-06-01

    Formation of dystrophic calcification deposits within the root canal of a tooth, have historically been difficult clinical endodontic complications. Presently, removal of such tissue, mineralized through the deposition of calcareous materials in a root canal (a 'calcified canal'), remains resistant to conventional endodontic techniques. The subsequent treatment primarily involves undesirable surgical procedures and/or loss of the tooth. Described in this clinical trial is a technique using free running (RF) pulsed, Nd:YAG laser energy to ablate hard calcified tissue which obstructed mechanical access of the root canal and root apex--a technique employed after conventional endodontic methods failed. This paper discusses the 'plasma' effect, 'spallation', canal illumination and transillumination using the helium-neon (HeNe) aiming beam. A free running pulsed, FR Nd:YAG dental laser was successfully used at 20 pulses per second and 1.75 watts to photovaporize and photodisrupt enough calcified tissue obstruction, to allow a conventional endodontic file to pass the canal blockage, and access the root apex. This clinical trial achieved the immediate, short term objective of endodontic hard tissue removal via photovaporization and photodisruption. The pulsed FR Nd:YAG dental laser used as described in this clinical report appears to be a very safe and very effective technique; offers a treatment alternative to traditional therapy that suggests high patient acceptance; and is significantly less stressful for the doctor and staff than traditional treatment options. Long-term, controlled scientific and clinical studies are necessary to establish the safety and efficacy of both the helium-neon energy for visualization and the low- watt pulsed FR Nd:YAG energy for photovaporization and photodisruption of hard calcified tissue within the root canal. Research is especially needed to understand the effects of low- watt, pulsed FR, Nd:YAG laser on the activity of osteoclasts and

  20. [Effects of laser radiation on the periodontium. An animal model approach. Effects of usual radiation dosage].

    Science.gov (United States)

    Noguerol Rodriguez, B; Alandez Chamorro, J; Cañizares Garcia, J; Campos Muñoz, A; Sicilia Felechosa, A

    1989-05-01

    Twenty four albino mice of forty days old were selected. Twelve forty days old albino mice were irradiated with a Helium-Neon laser source, dose of 10.50566 Jul/cm2. They were divided in two groups according to time of animal sacrifice (immediately after irradiation and ten days after). As control were used twelve mice using the same time as the experimental groups, but without radiation. T.E.M. ultrathin sections showed alteration only in the conjunctiva and in the bone tissues, but not in the epithelial tissue. The bone showed two osteocyte population according to their response to irradiation. The first population showed characteristic comparable with the controls, and the second showed alterations suggestive of a degenerative process. The connective tissue also showed two fibroblasts populations, the first showed signs of a big synthesizing activity, and the second, degenerative signs. The first fibroblast population appeared in the animals sacrificed immediately after irradiation.

  1. Gas laser having an integral optical resonator with external stabilizing means

    International Nuclear Information System (INIS)

    Hensolt, R.A.; Dowley, M.W.

    1975-01-01

    A gaseous laser having an internal optical resonator is provided with external stabilizing means for maintaining alignment of mirrors forming the optical resonator. Means are also provided for allowing expansion of the remainder of the gas-confining envelope relative to the stabilized resonator mirrors during the operation of the laser. (U.S.)

  2. Heat transfer modelling and stability analysis of selective laser melting

    International Nuclear Information System (INIS)

    Gusarov, A.V.; Yadroitsev, I.; Bertrand, Ph.; Smurov, I.

    2007-01-01

    The process of direct manufacturing by selective laser melting basically consists of laser beam scanning over a thin powder layer deposited on a dense substrate. Complete remelting of the powder in the scanned zone and its good adhesion to the substrate ensure obtaining functional parts with improved mechanical properties. Experiments with single-line scanning indicate, that an interval of scanning velocities exists where the remelted tracks are uniform. The tracks become broken if the scanning velocity is outside this interval. This is extremely undesirable and referred to as the 'balling' effect. A numerical model of coupled radiation and heat transfer is proposed to analyse the observed instability. The 'balling' effect at high scanning velocities (above ∼20 cm/s for the present conditions) can be explained by the Plateau-Rayleigh capillary instability of the melt pool. Two factors stabilize the process with decreasing the scanning velocity: reducing the length-to-width ratio of the melt pool and increasing the width of its contact with the substrate

  3. Magnetoelectric confinement and stabilization of Z pinch in a soft-x-ray Ar(+8) laser.

    Science.gov (United States)

    Szasz, J; Kiss, M; Santa, I; Szatmari, S; Kukhlevsky, S V

    2013-05-03

    Magnetoelectric confinement and stabilization of the plasma column in a soft-x-ray Ar(+8) laser, which is excited by a capillary Z pinch, via the combined magnetic and electric fields of the gliding surface discharge is experimentally demonstrated. Unlike soft-x-ray lasers excited by the conventional capillary Z pinches, the magnetoelectric confinement and stabilization of plasma do provide the laser operation without using any external preionization circuit.

  4. Stabilized high-power laser system for the gravitational wave detector advanced LIGO.

    Science.gov (United States)

    Kwee, P; Bogan, C; Danzmann, K; Frede, M; Kim, H; King, P; Pöld, J; Puncken, O; Savage, R L; Seifert, F; Wessels, P; Winkelmann, L; Willke, B

    2012-05-07

    An ultra-stable, high-power cw Nd:YAG laser system, developed for the ground-based gravitational wave detector Advanced LIGO (Laser Interferometer Gravitational-Wave Observatory), was comprehensively characterized. Laser power, frequency, beam pointing and beam quality were simultaneously stabilized using different active and passive schemes. The output beam, the performance of the stabilization, and the cross-coupling between different stabilization feedback control loops were characterized and found to fulfill most design requirements. The employed stabilization schemes and the achieved performance are of relevance to many high-precision optical experiments.

  5. A diode laser stabilization scheme for 40Ca+ single-ion spectroscopy

    Science.gov (United States)

    Rohde, F.; Almendros, M.; Schuck, C.; Huwer, J.; Hennrich, M.; Eschner, J.

    2010-06-01

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D2 line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in 40Ca+. The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D1 line. This stability is confirmed by the comparison of an excitation spectrum of a single 40Ca+ ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10-11 between 1 and 100 s.

  6. A diode laser stabilization scheme for 40Ca+ single-ion spectroscopy

    International Nuclear Information System (INIS)

    Rohde, F; Almendros, M; Schuck, C; Huwer, J; Hennrich, M; Eschner, J

    2010-01-01

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D 2 line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in 40 Ca + . The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D 1 line. This stability is confirmed by the comparison of an excitation spectrum of a single 40 Ca + ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10 -11 between 1 and 100 s.

  7. Frequency stabilization of multiple lasers on a single medium-finesse cavity

    Science.gov (United States)

    Han, Chengyin; Zhou, Min; Gao, Qi; Li, Shangyan; Zhang, Shuang; Qiao, Hao; Ai, Di; Zhang, Mengya; Lou, Ge; Luo, Limeng; Xu, Xinye

    2018-04-01

    We present a simple, compact, and robust frequency stabilization system of three lasers operating at 649, 759, and 770 nm, respectively. These lasers are applied in experiments on ytterbium optical lattice clocks, for which each laser needs to have a linewidth of a few hundred or tens of kilohertz while maintaining a favorable long-term stability. Here, a single medium-finesse cavity is adopted as the frequency reference and the standard Pound-Drever-Hall technique is used to stabilize the laser frequencies. Based on the independent phase modulation, multiple-laser locking is demonstrated without mutual intervention. The locked lasers are measured to have a linewidth of 100 kHz and the residual frequency drift is about 78.5 Hz s-1. This kind of setup provides a construction that is much simpler than that in previous work.

  8. Improvement of Laser Frequency Stabilization for the Optical Pumping Cesium Beam Standard

    International Nuclear Information System (INIS)

    Wang Qing; Duan Jun; Qi Xiang-Hui; Zhang Yin; Chen Xu-Zong

    2015-01-01

    A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an important factor that limits the long-term frequency stability. We minimize the drift of the light angle by using a fiber-coupled output, and lock the frequency of a distributed-feedback diode laser to the fluorescence spectrum of the atomic beam. The measured frequency stability is about 3.5 × 10 −11 at 1 s and reaches 1.5 × 10 −12 at 2000 s. The Allan variance keeps going down for up to thousands of seconds, indicating that the medium- and long-term stability of the laser frequency is significantly improved and perfectly fulfills the requirement for the optical pumping cesium clock. (paper)

  9. Channeling and stability of laser pulses in plasmas

    International Nuclear Information System (INIS)

    Sprangle, P.; Krall, J.; Esarey, E.

    1995-01-01

    A laser pulse propagating in a plasma is found to undergo a combination of hose and modulation instabilities. The coupled equations for the laser beam envelope and centroid are derived and solved for a laser pulse of finite length propagating through either a uniform plasma or preformed plasma density channel. The laser envelope equation describes the pulse self-focusing and optical guiding in plasmas and is used to analyze the self-modulation instability. The laser centroid equation describes the transverse motion of the laser pulse (hosing) in plasmas. Significant coupling between the centroid and envelope motion as well as harmonic generation in the envelope can occur. In addition, the transverse profile of the generated wake field is strongly affected by the laser hose instability. Methods to reduce the laser hose instability are demonstrated. copyright 1995 American Institute of Physics

  10. Laser speckle imaging of atherosclerotic plaques through optical fiber bundles

    Science.gov (United States)

    Nadkarni, Seemantini K.; Bouma, Brett E.; Yelin, Dvir; Gulati, Amneet; Tearney, Guillermo J.

    2009-01-01

    Laser speckle imaging (LSI), a new technique that measures an index of plaque viscoelasticity, has been investigated recently to characterize atherosclerotic plaques. These prior studies demonstrated the diagnostic potential of LSI for detecting high-risk plaques and were conducted ex vivo. To conduct intracoronary LSI in vivo, the laser speckle pattern must be transmitted from the coronary wall to the image detector in the presence of cardiac motion. Small-diameter, flexible optical fiber bundles, similar to those used in coronary angioscopy, may be incorporated into an intravascular catheter for this purpose. A key challenge is that laser speckle is influenced by inter-fiber leakage of light, which may be exacerbated during bundle motion. In this study, we tested the capability of optical fiber bundles to transmit laser speckle patterns obtained from atherosclerotic plaques and evaluated the influence of motion on the diagnostic accuracy of fiber bundle-based LSI. Time-varying helium-neon laser speckle images of aortic plaques were obtained while cyclically moving the flexible length of the bundle to mimic coronary motion. Our results show that leached fiber bundles may reliably transmit laser speckle images in the presence of cardiac motion, providing a viable option to conduct intracoronary LSI. PMID:19021396

  11. Space-Qualifiable High Reliability Frequency-Stabilized CW Laser Source Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the SBIR Phase II effort to develop and space-qualify a 1.06 micron high reliability frequency-stabilized CW laser source that fully satisfies the...

  12. Stabilization of the Absolute Frequency and Phase of a Compact, Low Jitter Modelocked Semiconductor Diode Laser

    National Research Council Canada - National Science Library

    Delfyett, Peter J., Jr

    2005-01-01

    .... To achieve this, an intracavity Pound-Drever-Hall technique was used on a 10 GHz harmonically mode-locked semiconductor ring laser and obtained a simultaneous optical frequency comb stabilization...

  13. Space-Qualifiable High Reliability Frequency-Stabilized CW Laser Source Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development and space qualification of a high reliability frequency-stabilized CW laser source at 1064 nm wavelength region to satisfy the...

  14. Constructing a Laser Stabilization System for a Parity Non-Conservation Experiment with Francium

    Science.gov (United States)

    Dehart, A. C.; Gwinner, Gerald; Kossin, Michael; Behr, John; Gorelov, Alexandre; Kalita, Mukut; Pearson, Matthew; Aubin, Seth; Gomez Garcia, Eduardo; Orozco, Luis

    2017-04-01

    We are developing an experiment at TRIUMF to test the Standard model at low energies by measuring Parity Non-Conservation (PNC) effects in francium. Current efforts include preparations to study the 7s - 8s electric dipole (E1) forbidden transition in francium at 507 nm under the influence of an electric field. Fr has no stable isotope; therefore to frequency-stabilize our laser at 507 nm, we are developing a laser stabilization system by using the Pound-Drever-Hall technique with a Fabry-Perot cavity made of Ultra Low Expansion Glass (ULE) as our stable frequency reference. The system will stabilize a 1014 nm laser, which will be frequency doubled to 507 nm, before sending the light to our cold and trapped francium sample. We will report on our recent experiences with the laser stabilization system. Supported by NSERC, NRC/TRIUMF, DOE, NSF, CONACYT, Fulbright, and U. of Manitoba.

  15. Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Barry, Matthew; /Auburn U.

    2015-08-19

    This presentation covers data collected on two commercial laser stabilization systems, Guidestar-II and MRC, and two optical imaging systems. Additionally, general information about LCLS-II and how to go about continuing-testing is covered.

  16. Development of laser technology (Development of the wavelength tuning and the output stabilization technology)

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Hyung Ki; Kim, Sung Ho; Cha, Byung Hun; Rhee, Yong Joo; Lim, Chang Hwan; Yoo, Byung Duk; Song, Kyu Seok; Choe, An Seong; Baik, Dae Hyun; Kim, Jung Bog; Jeong, Do Young; Jung, Euo Chang; Han, Jae Min; Ko, Do Kyeong; Lee, Byung Cheol; Kim, Sun Kook; Nam, Sung Mo; Rho, Si Pyo; Yi, Jong Hoon; Choi, Hwa Rim; Lee, Yong Bum; Kim, Woong Ki

    1992-12-01

    Various types of the dye laser are developed and investigated for the wavelength tuning and the output stabilization. And a Ti:sapphire laser system was developed to expand the lasing frequency and the injection seeding was executed in this Ti:sapphire laser. New frequency tuning mechanism using a wedge prism was developed and it was proved that better fine frequency tuning can be achieved by rotating the wedge prism instead of the tuning mirror. Efficiency and the parameters of the high power dye laser amplifier system were calculated by the computer simulation. The characteristics of the dye nozzle were examined for the stabilization of the high power, high repetition rate dye laser system and the output characteristics of the dye laser using the nozzle are investigated. (Author)

  17. Improvement of temperature-stability in a quantum well laser with asymmetric barrier layers

    DEFF Research Database (Denmark)

    Zhukov, Alexey E.; Kryzhanovskaya, Natalia V.; Zubov, Fedor I.

    2012-01-01

    We fabricated and tested a quantum well laser with asymmetric barrier layers. Such a laser has been proposed earlier to suppress bipolar carrier population in the optical confinement layer and thus to improve temperature-stability of the threshold current. As compared to the conventional reference...

  18. A High Power CH3OH Laser System Using Stark Stabilized CO2 Pump Lasers

    Science.gov (United States)

    Hutchinson, D. P.; Bennett, C. A.; Lee, J.; Fl etcher, L. K.; Ma, C. H.; Vander Sluis, K. L.

    1988-11-01

    A dual channel, 119μm wavelength laser system has been constructed for the ATF experiment at Oak Ridge. The pump lasers utilize external Stark cells for locking the CO2 laser to the absorption frequency of the CH3OH lasers. Stark plates have also been attached to the dielectric waveguide resonators of the FIR lasers to affect precise tuning of the 119 μm lasers.

  19. A digital frequency stabilization system of external cavity diode laser based on LabVIEW FPGA

    Science.gov (United States)

    Liu, Zhuohuan; Hu, Zhaohui; Qi, Lu; Wang, Tao

    2015-10-01

    Frequency stabilization for external cavity diode laser has played an important role in physics research. Many laser frequency locking solutions have been proposed by researchers. Traditionally, the locking process was accomplished by analog system, which has fast feedback control response speed. However, analog system is susceptible to the effects of environment. In order to improve the automation level and reliability of the frequency stabilization system, we take a grating-feedback external cavity diode laser as the laser source and set up a digital frequency stabilization system based on National Instrument's FPGA (NI FPGA). The system consists of a saturated absorption frequency stabilization of beam path, a differential photoelectric detector, a NI FPGA board and a host computer. Many functions, such as piezoelectric transducer (PZT) sweeping, atomic saturation absorption signal acquisition, signal peak identification, error signal obtaining and laser PZT voltage feedback controlling, are totally completed by LabVIEW FPGA program. Compared with the analog system, the system built by the logic gate circuits, performs stable and reliable. User interface programmed by LabVIEW is friendly. Besides, benefited from the characteristics of reconfiguration, the LabVIEW program is good at transplanting in other NI FPGA boards. Most of all, the system periodically checks the error signal. Once the abnormal error signal is detected, FPGA will restart frequency stabilization process without manual control. Through detecting the fluctuation of error signal of the atomic saturation absorption spectrum line in the frequency locking state, we can infer that the laser frequency stability can reach 1MHz.

  20. Long-term frequency stabilized and linewidth-narrowed cw-laser system for excitation of lithium Rydberg states

    Science.gov (United States)

    Saakyan, S. A.; Sautenkov, V. A.; Zelener, B. B.

    2018-01-01

    We transfer the frequency stability from a diode laser, which was locked to Doppler-free saturation absorption resonance in lithium vapor cell, to a tunable Ti-sapphire laser. We get the laser linewidth stability ±0.5 MHz. The uv laser system which included the stabilized Ti-sapphire laser and frequency doubler has output optical beam with power near 100 mW and wavelength 350 nm. This uv laser system will be used for excitation and study of Rydberg states in lithium atoms.

  1. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  2. Realization and characterization of a stabilized power supply for a laser diode

    International Nuclear Information System (INIS)

    Houji, Imen

    2010-01-01

    This final project study is entitled realization and characterization of a stabilized power supply for a diode laser. It was developed at the National Center for Nuclear Sciences and Technology at Sidi Thabet. In a first step, we are interested on the physics of lasers and its applications in different fields. We have also focused on the electronic manufacturing of diode lasers. In a second part, we have presented in detail the current stabilized power supply and the detailed description of the various blocks of this electronic schema. Before the experimental realization, we simulated the electronic schema using the commercial software P roteus 7 . Finally we presented the practical realization of various cards.

  3. Dynamics of bad-cavity-enhanced interaction with cold Sr atoms for laser stabilization

    DEFF Research Database (Denmark)

    Schäffer, S. A.; Christensen, B. T.R.; Henriksen, M. R.

    2017-01-01

    Hybrid systems of cold atoms and optical cavities are promising systems for increasing the stability of laser oscillators used in quantum metrology and atomic clocks. In this paper we map out the atom-cavity dynamics in such a system and demonstrate limitations as well as robustness of the approa...... transfer function relating input field to output field. The cavity dynamics is shown to have only little influence on the prospects for laser stabilization, making the system robust towards cavity fluctuations and ideal for the improvement of future narrow linewidth lasers....

  4. Kilohertz linewidth from frequency-stabilized mid-infrared quantum cascade lasers

    International Nuclear Information System (INIS)

    Williams, Richard M.; Kelly, James F.; Hartman, John S.; Sharpe, Steven W.; Taubman, Matthew S.; Hall, John L.; Capasso, Federico; Gmachl, Claire; Sivco, Deborah L.; Baillargeon, James N.

    1999-01-01

    Frequency stabilization of mid-IR quantum cascade (QC) lasers to the kilohertz level has been accomplished by use of electronic servo techniques. With this active feedback, an 8.5-μm QC distributed-feedback laser is locked to the side of a rovibrational resonance of nitrous oxide (N 2 O) at 1176.61 cm -1 . A stabilized frequency-noise spectral density of 42 Hz/√(Hz) has been measured at 100 kHz; the calculated laser linewidth is 12 kHz. (c) 1999 Optical Society of America

  5. Frequency and amplitude stabilized terahertz quantum cascade laser as local oscillator

    NARCIS (Netherlands)

    Ren, Y.; Hayton, D.J.; Hovenier, J.N.; Cui, M.; Gao, J.R.; Klapwijk, T.M.; Shi, S.C.; Kao, T.Y.; Hu, Q.; Reno, J.L.

    2012-01-01

    We demonstrate an experimental scheme to simultaneously stabilize the frequency and amplitude of a 3.5 THz third-order distributed feedback quantum cascade laser as a local oscillator. The frequency stabilization has been realized using a methanol absorption line, a power detector, and a

  6. Towards passive and active laser stabilization using cavity-enhanced atomic interaction

    DEFF Research Database (Denmark)

    Schäffer, Stefan Alaric; Christensen, Bjarke Takashi Røjle; Rathmann, Stefan Mossor

    2017-01-01

    Ultra stable frequency references such as the ones used in optical atomic clocks and for quantum metrology may be obtained by stabilizing a laser to an optical cavity that is stable over time. State-of-the-art frequency references are constructed in this way, but their stabilities are currently...... experimental efforts derived from these proposals, to use cavity-enhanced interaction with atomic 88Sr samples as a frequency reference for laser stabilization. Such systems can be realized using both passive and active approaches where either the atomic phase response is used as an error signal, or the narrow...... atomic transition itself is used as a source for a spectrally pure laser. Both approaches shows the promise of being able to compete with the current state of the art in stable lasers and have similar limitations on their ultimately achievable linewidths [1, 2]....

  7. The study of the structural stability of the spiral laser beams propagation through inhomogeneous phase medium

    Science.gov (United States)

    Zinchik, Alexander A.; Muzychenko, Yana B.

    2015-06-01

    This paper discusses theoretical and experimental results of the investigation of light beams that retain their intensity structure during propagation and focusing. Spiral laser beams are a family of laser beams that preserve the structural stability up to scale and rotation with the propagation. Properties of spiral beams are of practical interest for laser technology, medicine and biotechnology. Researchers use a spiral beams for movement and manipulation of microparticles. Functionality laser manipulators can be significantly enhanced by using spiral beams whose intensity remains invariable. It is well known, that these beams has non-zero orbital angular momentum. Spiral beams have a complicated phase distribution in cross section. In this paper we investigate the structural stability of the laser beams having a spiral phase structure by passing them through an inhomogeneous phase medium. Laser beam is passed through a medium is characterized by a random distribution of phase in the range 0..2π. The modeling was performed using VirtualLab 5.0 (manufacturer LightTrans GmbH). Compared the intensity distribution of the spiral and ordinary laser beam after the passage of the inhomogeneous medium. It is shown that the spiral beams exhibit a significantly better structural stability during the passage phase heterogeneous environments than conventional laser beams. The results obtained in the simulation are tested experimentally. Experimental results show good agreement with the theoretical results.

  8. Report on the Power and Detector Stability Measurements for the QC Laser Alignment System

    Energy Technology Data Exchange (ETDEWEB)

    Myers, Tanya L.; Bonebrake, Christopher A.; Cannon, Bret D.; Suarez, Reynold; Stewart, Timothy L.; Hatchell, Brian K.

    2003-12-15

    This report summarizes the preliminary tests that PNNL has performed to date for the Quantum Cascade (QC) Laser Alignment System that is being developed for the Using Client for a classified application. PNNL is designing, fabricating, assembling, and testing the QC Laser Alignment System and has a subcontract with Maxion Technologies, Inc. for development and production of the QC laser devices to be used in this system. The QC lasers furnished by Maxion will be incorporated into the QC Laser Alignment System by PNNL. The QC Laser Alignment System consists of five Alignment Source Assemblies (ASAs) and a computer control system with graphical user interface (GUI). Each ASA has two QC lasers along with a temperature sensor. The system design also includes an optical detector for each QC laser to measure the output power of the rear facet for additional stabilization. The system will monitor the voltage across the QC laser, the temperature, the current, and the signal from the optical detectors to ensure the system is within the tolerances specified in the System Specifications. The System Specifications require that the relative power between lasers on the same ASA be maintained at {+-}1% and among the lasers on different ASAs at {+-}2.5%. For the tests reported here, we attempted to examine the power stability of the QC laser as well as the variability of the optical detectors to ensure the system will adhere to these specifications. These preliminary tests did not incorporate the actual ASA mounting scheme or the QC lasers that are being fabricated by Maxion to operate at the specified temperature of -50 C. Thus, we expect the performance from these results to differ from the actual results that can be achieved in the QC Laser Alignment System. Current limitations with the mounting scheme created problems with the power stability due to thermal cycling. Short-term power stability where thermal cycling was not a problem showed power fluctuations within the 1

  9. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz....

  10. Stabilizing operation point technique based on the tunable distributed feedback laser for interferometric sensors

    Science.gov (United States)

    Mao, Xuefeng; Zhou, Xinlei; Yu, Qingxu

    2016-02-01

    We describe a stabilizing operation point technique based on the tunable Distributed Feedback (DFB) laser for quadrature demodulation of interferometric sensors. By introducing automatic lock quadrature point and wavelength periodically tuning compensation into an interferometric system, the operation point of interferometric system is stabilized when the system suffers various environmental perturbations. To demonstrate the feasibility of this stabilizing operation point technique, experiments have been performed using a tunable-DFB-laser as light source to interrogate an extrinsic Fabry-Perot interferometric vibration sensor and a diaphragm-based acoustic sensor. Experimental results show that good tracing of Q-point was effectively realized.

  11. Stability of the mode-locking regime in tapered quantum-dot lasers

    Science.gov (United States)

    Bardella, P.; Drzewietzki, L.; Rossetti, M.; Weber, C.; Breuer, S.

    2018-02-01

    We study numerically and experimentally the role of the injection current and reverse bias voltage on the pulse stability of tapered, passively mode-locked, Quantum Dot (QD) lasers. By using a multi-section delayed differential equation and introducing in the model the QD inhomogenous broadening, we are able to predict the onset of leading and trailing edge instabilities in the emitted pulse trains and to identify specific trends of stability in dependence on the laser biasing conditions. The numerical results are confirmed experimentally trough amplitude and timing stability analysis of the pulses.

  12. Chasing the thermodynamical noise limit in whispering-gallery-mode resonators for ultrastable laser frequency stabilization.

    Science.gov (United States)

    Lim, Jinkang; Savchenkov, Anatoliy A; Dale, Elijah; Liang, Wei; Eliyahu, Danny; Ilchenko, Vladimir; Matsko, Andrey B; Maleki, Lute; Wong, Chee Wei

    2017-03-31

    Ultrastable high-spectral-purity lasers have served as the cornerstone behind optical atomic clocks, quantum measurements, precision optical microwave generation, high-resolution optical spectroscopy, and sensing. Hertz-level lasers stabilized to high-finesse Fabry-Pérot cavities are typically used for these studies, which are large and fragile and remain laboratory instruments. There is a clear demand for rugged miniaturized lasers with stabilities comparable to those of bulk lasers. Over the past decade, ultrahigh-Q optical whispering-gallery-mode resonators have served as a platform for low-noise microlasers but have not yet reached the stabilities defined by their fundamental noise. Here, we show the noise characteristics of whispering-gallery-mode resonators and demonstrate a resonator-stabilized laser at this limit by compensating the intrinsic thermal expansion, allowing a sub-25 Hz linewidth and a 32 Hz Allan deviation. We also reveal the environmental sensitivities of the resonator at the thermodynamical noise limit and long-term frequency drifts governed by random-walk-noise statistics.High-quality optical resonators have the potential to provide a miniaturized frequency reference for metrology and sensing but they often lack stability. Here, Lim et al. experimentally characterize the stability of whispering-gallery resonators at their fundamental noise limits.

  13. High stability laser for next generation gravity missions

    Science.gov (United States)

    Nicklaus, K.; Herding, M.; Wang, X.; Beller, N.; Fitzau, O.; Giesberts, M.; Herper, M.; Barwood, G. P.; Williams, R. A.; Gill, P.; Koegel, H.; Webster, S. A.; Gohlke, M.

    2017-11-01

    With GRACE (launched 2002) and GOCE (launched 2009) two very successful missions to measure earth's gravity field have been in orbit, both leading to a large number of publications. For a potential Next Generation Gravity Mission (NGGM) from ESA a satellite-to-satellite tracking (SST) scheme, similar to GRACE is under discussion, with a laser ranging interferometer instead of a Ka-Band link to enable much lower measurement noise. Of key importance for such a laser interferometer is a single frequency laser source with a linewidth collaboration the JPL contributions are the instrument electronics, the reference cavity and the single frequency laser, while STI as the German industry prime is responsible for the optical bench and the retroreflector. In preparation of NGGM an all European instrument development is the goal.

  14. Iodine Stabilized Seed Laser for Space Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I effort proposes to establish the feasibility of leveraging advances in compact laser technology with integration of space qualified techniques into...

  15. Emission characteristics and stability of laser ion sources

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Velyhan, Andriy; Krouský, Eduard; Láska, Leoš; Rohlena, Karel; Jungwirth, Karel; Ullschmied, Jiří; Lorusso, A.; Velardi, L.; Nassisi, V.; Czarnecka, A.; Ryc, L.; Parys, P.; Wolowski, J.

    2010-01-01

    Roč. 85, č. 5 (2010), s. 617-621 ISSN 0042-207X R&D Projects: GA AV ČR IAA100100715 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : laser ion sources * ion emission reproducibility * thermal and fast ions * ion temperature * centre-of-mass velocity Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.048, year: 2010

  16. A diode laser stabilization scheme for {sup 40}Ca{sup +} single-ion spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rohde, F; Almendros, M; Schuck, C; Huwer, J; Hennrich, M; Eschner, J, E-mail: felix.rohde@icfo.e [ICFO-Institut de Ciencies Fotoniques, Mediterranean Technology Park, E-08860 Castelldefels, Barcelona (Spain)

    2010-06-14

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D{sub 2} line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in {sup 40}Ca{sup +}. The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D{sub 1} line. This stability is confirmed by the comparison of an excitation spectrum of a single {sup 40}Ca{sup +} ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10{sup -11} between 1 and 100 s.

  17. Three-Dimensional Numerical Analysis for Posture Stability of Laser Propulsion Vehicle

    Science.gov (United States)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2011-11-01

    We have developed a three-dimensional hydrodynamics code coupling equation of motion of a rigid body for analyzing posture stability of laser propulsion vehicle through numerical simulations of flowfield interacting with unsteady motion of the vehicle. Asymmetric energy distribution is initially added around the focal spot (ring) in order to examine posture stability against an asymmetric blast wave resulting from a laser offset for a lightcraft-type vehicle. The vehicle moves to cancel out the offset from initial offset. However, the Euler angle grows and never returns to zero in a time scale of laser pulse. Also, we found that the vehicle moves to cancel tipping angle when the laser is irradiated to the vehicle with initial tipping angle over the wide angle range, through the vehicle cannot get sufficient restoring force in particular angle, and the tipping angle does not decrease from the initial value for that case.

  18. Frequency stabilization of internal-mirror He-Ne lasers by air cooling.

    Science.gov (United States)

    Qian, Jin; Liu, Zhongyou; Shi, Chunying; Liu, Xiuying; Wang, Jianbo; Yin, Cong; Cai, Shan

    2012-09-01

    Instead of the traditional heating method, the cavity length of an internal-mirror He-Ne laser is controlled by air cooling which is implemented by a mini cooling fan. The responsive property of the cooling fan and the thermal expansion of the internal-mirror laser tube are investigated. According to these investigations, a controlling system is designed to drive the cooling fan controlling the cavity length of the laser. Then the frequency is stabilized by comparing the light intensities of two operating longitudinal modes. The results of beating with an iodine stabilized He-Ne laser show that a relative uncertainty (Δf/f-) of 4.3×10(-9) in 5 months, a frequency fluctuation of <1.4 MHz, and an Allan deviation of 6×10(-11) (τ=10,000 s) in 20 h are obtained.

  19. Stability of the single-mode output of a laser diode array with phase conjugate feedback

    DEFF Research Database (Denmark)

    Juul Jensen, S.; Løbel, M.; Petersen, P.M.

    2000-01-01

    . The output power and the center wavelength are found to be extremely stable in a 100 h stability measurement. External feedback of the output beam into the laser is seen to decrease both the spatial and the temporal coherence of the output significantly. We outline an approach to obtain a stable single......The stability of the output of a single-mode laser diode array with frequency selective phase conjugate feedback has been investigated experimentally. Both the long-term stability of the laser output and the sensitivity to feedback generated by external reflection of the output beam are examined......-mode output when external feedback is present using spatial filtering in the path of the output beam. (C) 2000 American Institute of Physics....

  20. Spectroscopic investigations of novel pharmaceuticals: Stability and resonant interaction with laser beam

    Science.gov (United States)

    Smarandache, Adriana; Boni, Mihai; Andrei, Ionut Relu; Handzlik, Jadwiga; Kiec-Kononowicz, Katarzyna; Staicu, Angela; Pascu, Mihail-Lucian

    2017-09-01

    This paper presents data about photophysics of two novel thio-hydantoins that exhibit promising pharmaceutical properties in multidrug resistance control. Time stability studies are necessary to establish the proper use of these compounds in different applications. As for their administration as drugs, it is imperative to know their shelf life, as well as storage conditions. At the same time, laser induced modified properties of the two new compounds are valuable to further investigate their specific interactions with other materials, including biological targets. The two new thio-hydantoins under generic names SZ-2 and SZ-7 were prepared as solutions in dimethyl sulfoxide at different concentrations, as well as in deionised water. For the stability assay they were kept in various light/temperature conditions up to 60 days. The stability was estimates based on UV-vis absorption measurements. The samples in bulk shape were exposed different time intervals to laser radiation emitted at 266 nm as the fourth harmonic of a Nd:YAG laser. The resonant interaction of the studied compounds with laser beams was analysed through spectroscopic methods UV-vis and FTIR absorption, as well as laser induced fluorescence spectroscopy. As for stability assay, only solutions kept in dark at 4 °C have preserved the absorption characteristics, considering the cumulated measuring errors, less than one week. The vibrational changes that occur in their FTIR and modified fluorescence spectra upon laser beam exposure are also discussed. A result of the experimental analysis is that modifications are induced in molecular structures of the investigated compounds by resonant interaction with laser radiation. This fact evidences that the molecules are photoreactive and their characteristics might be shaped through controlled laser radiation exposure using appropriate protocols. This conclusion opens many opportunities both in the biomedical field, but also in other industrial activities

  1. Evaluation of laser therapy and routine treatment modalities in the management of myofascial pain dysfunction syndrome

    Directory of Open Access Journals (Sweden)

    Smriti B Jagdhari

    2015-01-01

    Full Text Available Objective: To evaluate the efficacy of laser as a monotherapy and in combination with exercise therapy in comparison to only exercise in the treatment of Myofascial Pain Dysfunction Syndrome (MPDS or Temporomandibular Myofascial Pain. Materials and Methods: A total of 60 patients with MPDS were included in the study and were randomly divided into three groups: exercise, laser, and the combination of both (exercise and laser. Results: Significant reduction in pain at rest and pain on movement was observed with all three types of treatment modalities. Pain reduction was more in those patients who received combination of exercise and laser therapy. Similarly, decrease in the muscle tenderness was more when combination of exercise and laser therapy was used. Conclusion: The ideal therapy should be fast, cheap, and have a long-term effect. Laser (Helium Neon as monotherapy or in combination with exercise had shown promising results and can be used as an effective treatment modality for the treatment of MPDS.

  2. In vivo and in vitro HeNe laser effects on phagocyte functions

    Energy Technology Data Exchange (ETDEWEB)

    Ricevuti, G.; Mazzone, A.; Monaia, C.; Fratino, P.; Degiulio, R.; Dell' Acqua, R.; Leonardi, G.; Jucci, A.; Sacchi, S. (Univ. of Pavia (Italy))

    1989-10-01

    The goal of this work was to evaluate the effect of helium-neon (HeNe) laser irradiation on immunocompetent cells. We used the in vivo skin window method and in vitro granulocyte function tests. The study of cellular migration showed a marked decrease in vitro and in vivo in a dose-independent manner. Superoxide release was not modified by laser irradiation. The granulocyte's aggregation, when using PHA and PMA, presented a reduction that was statistically very significant, not as a subordinate dose. An increase of the release of ATP was demonstrated only at 4 joules and precedes granulocyte aggregation. When using Ca2+ ionophore A23187 as stimulus, laser irradiation at 1, 2 or 4J did not show any modification of granulocyte aggregation. The monoclonal antibody 60.1, which identifies a membrane antigen fundamental for aggregation and chemotaxis, is expressed in normal amounts on granulocyte membranes both before and after irradiation with a HeNe laser. In fact, laser irradiation preferentially attacks the area of the cellular centrosome that determines a modification of cellular morphology. The electron microscope and immunofluorescence study with a monoclonal antibody have pointed out a disorganization of the microtubules. The alteration of some of the granulocyte functions is correlated to the damage in the centrioles. The granulocyte mitochondrial system and surface membrane remain intact, and this explains the normal production and release of free radicals. Further experiments are necessary to evaluate the clinical application of lasers in various diseases with immunophagocytic pathogenesis.

  3. Characterization of Atherosclerotic Plaques by Laser Speckle Imaging

    Science.gov (United States)

    Nadkarni, Seemantini K.; Bouma, Brett E.; Helg, Tina; Chan, Raymond; Halpern, Elkan; Chau, Alexandra; Minsky, Milan Singh; Motz, Jason T.; Houser, Stuart L.; Tearney, Guillermo J.

    2010-01-01

    Background A method capable of determining atherosclerotic plaque composition and measuring plaque viscoelasticity can provide valuable insight into intrinsic features associated with plaque rupture and can enable the identification of high-risk lesions. In this article, we describe a new optical technique, laser speckle imaging (LSI), that measures an index of plaque viscoelasticity. We evaluate the potential of LSI for characterizing atherosclerotic plaque. Methods and Results Time-varying helium-neon laser speckle images were acquired from 118 aortic plaque specimens from 14 human cadavers under static and deforming conditions (0 to 200 μm/s). Temporal fluctuations in the speckle patterns were quantified by exponential fitting of the normalized cross-correlation of sequential frames in each image series of speckle patterns to obtain the exponential decay time constant, τ. The decorrelation time constants of thin-cap fibroatheromas (TCFA) (τ=47.5±19.2 ms) were significantly lower than those of other atherosclerotic lesions (P90%. Speckle decorrelation time constants demonstrated strong correlation with histological measurements of plaque collagen (R=0.73, P0.05). Conclusions The measurement of speckle decorrelation time constant from laser speckle images provides an index of plaque viscoelasticity and facilitates the characterization of plaque type. Our results demonstrate that LSI is a highly sensitive technique for characterizing plaque and identifying thin-cap fibroatheromas. PMID:16061738

  4. Studies on the influence of laser beams on wound granulation

    International Nuclear Information System (INIS)

    Brunner, R.

    1982-01-01

    The influence of laser light of law energy on wound healing was tested on 204 rats in a blind study. The growth of granulation tissue in a polyvinylchloride cylinder implanted on the backs of the animals served as parameter for wound healing. Irradiation was carried out with a helium-neon laser (wavelength 632.8 nm) at daily doses of 0.5 J/cm 2 , 1.5 J/cm 2 , 4 J/cm 2 , 10 J/cm 2 and 20 J/cm 2 , and with incoherent non-linear polarized red light (wavelength 630 nm) with a daily dose of 4 J/cm 2 . This was repeated 8 times. Laser irradiation caused a statistically significant increase in wet and dry granulation tissue weight of 25% in the dose range 1.5 J/cm 2 to 20 J/cm 2 . At 0.5 J/cm 2 the effect was less, but the least effect was achieved by non-linear polarized incoherent red light. Bacteriological evaluation of wound germ counts revealed a marginally lower presence of high germ cell densities. In irradiated animals, histological and enzyme cytochemical findings revealed, in addition to a significant findings revealed, in addition to a significant increase in mast cells, a smaller increase in fibroblast count and a slight decrease in granulocytic and histiocytic elements. The biochemical evaluation of granulation tissue revealed no differences in collagen content between irradiated and unirradiated animals. (orig.) [de

  5. Shot-noise-limited laser power stabilization with a high-power photodiode array.

    Science.gov (United States)

    Kwee, Patrick; Willke, Benno; Danzmann, Karsten

    2009-10-01

    The output power of a cw Nd:YAG laser was stabilized in a dc-coupled feedback loop with a low-noise multiphotodiode detector and an electro-optic amplitude modulator in the frequency band from 1 Hz to 1 kHz. For the first time, to our knowledge, an independently measured relative power noise of 2.4 x 10(-9) Hz(-1/2) at 10 Hz was achieved, fulfilling the power stability requirements of the Advanced LIGO (Laser Interferometer Gravitational-Wave Observatory) gravitational wave detector.

  6. Motion Stabilization by Using Laser Distance Sensor for Biped Walking Robot with Flexible Ankle Joints

    Science.gov (United States)

    Ito, Masanori; Oda, Naoki

    This paper describes an approach to motion stabilization by using laser distance sensors for biped robots with flexible ankle joints. To avoid the vibrated zero moment point (ZMP) behavior caused by mechanical resonance, a vibration control method is proposed in the paper. In our approach, the deformation of the ankle joint is measured by using laser distance sensors, and the detected deformation is translated into the equivalent reaction force at the center of gravity. The feedback of the reaction force enables the stabilization of the walking motion in a manner similar to resonance ratio control. The validity of the proposed method is evaluated by several experimental results.

  7. In situ optoacoustic measurement of the pointing stability of femtosecond laser beams

    Science.gov (United States)

    Pushkarev, D.; Mitina, E.; Uryupina, D.; Volkov, R.; Karabytov, A.; Savel'ev, A.

    2018-02-01

    A new method for the in situ acoustic measurement of the beam pointing stability (BPS) of powerful pulsed lasers is tested. A broadband (~6 MHz) piezoelectric transducer placed a few millimeters from the laser spark produces an electric pulse. We show that variation in time of the position of this pulse can be used to assess the BPS down to 1 µrad in a few hundred laser shots. The estimated value coincides well with the BPS estimated using standard measurement in the far field.

  8. Pulsed laser deposition of yttria-stabilized zirconium dioxide with a high repetition rate picosecond fiber laser

    International Nuclear Information System (INIS)

    Salminen, Turkka; Hahtala, Mikko; Seppaelae, Ilkka; Niemi, Tapio; Pessa, Markus

    2010-01-01

    We report the use of a mode-locked fiber laser in pulsed laser deposition (PLD) of yttria-stabilized zirconium oxide. The fiber laser produces picosecond pulses with megahertz repetition rates at the wavelength of 1060 nm. We have investigated the effects of the time delay and the physical overlapping of the consecutive pulses on the ablation thresholds and the properties of the deposited films. Our results show existence of two distinct evaporation modes: (1) a single pulse evaporation mode observed for low overlapping and long time delays between the pulses and (2) a high repetition rate evaporation mode for high overlapping with short delays. The first mode is characterized by evaporation of nanoparticles and clusters and yields structured films with high surface area. The second mode yields smooth films, with evaporation characteristics closer to those of thermal evaporation than traditional PLD. (orig.)

  9. Stabilization of the quasi-periodic motion of a Q-switched Nd:YAG laser

    International Nuclear Information System (INIS)

    Kim, Chil-Min; Rim, Sunghwan; Kye, Won-Ho; Kim, Jeong-Moog; Lee, Kang-Soo

    2004-01-01

    We have developed a stabilization method of quasi-periodicity based on a return map. The method is explained in the forced Van der Pol oscillator, and applied experimentally to a quasi-periodic output of a Q-switched Nd:YAG laser. Even though the attractors have no unstable periodic orbit, we were able to stabilize them to an arbitrarily chosen orbit by targeting the trajectory into it

  10. The theory of stability, bistability, and instability in three-mode class-A lasers

    International Nuclear Information System (INIS)

    Jahanpanah, J; Rahdar, A A

    2014-01-01

    Instability is an inevitable and common problem in all different kinds of lasers when they are oscillating in both single-and multi-mode states. Here, the stability conditions are investigated for a three-mode class-A laser. A set of linear equations is derived for the stable oscillation of the cavity central mode together with its left and right adjacent longitudinal modes. The coefficient determinant of stability equations is Hermitian and equal to zero for the roots of two diagonal arrays. In other words, the novelty of our work is to expand the stability coefficient determinant in terms of main diagonal arrays rather than for one row or one column. These diagonal roots lead to two lower and upper boundary curves in the form of a bifurcation. The lower boundary curve mimics the single-mode laser and delimits the instability region (with no above-threshold oscillating mode) from the bistability region (with two above-threshold oscillating modes). The upper boundary curve mimics the two-mode laser and delimits the bistability region from the stability region, in which all three-longitudinal modes are simultaneously oscillating in the above-threshold state. (paper)

  11. Ultrastable offset-locked frequency-stabilized heterodyne laser source with water cooling.

    Science.gov (United States)

    Yang, Hongxing; Yang, Ruitao; Hu, Pengcheng; Tan, Jiubin

    2017-11-20

    An ultrastable frequency-stabilized He-Ne laser with a water-cooling structure has been developed for a high-speed and high-accuracy heterodyne interferometer. To achieve high frequency stability and reproducibility, a two-mode He-Ne laser was offset locked to an iodine-stabilized laser. An improved synchronous multi-cycle offset frequency-measurement method with a gate time of an integer multiple of the modulation period was employed to remove the frequency-modulation effect on the offset-frequency counter. A water-cooling structure based on the double-helix structure was established to provide a stable and low-temperature working environment. This structure can remarkably reduce the frequency instability arising from the environmental temperature variation and the thermal pollution released from the laser to the environment. The experimental results indicate that the frequency stability according to the Allen variance is better than 2.3×10 -11 (τ=10  s) and the frequency reproducibility is better than 4.5×10 -10 .

  12. Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Barry, Matthew [Auburn Univ., AL (United States)

    2015-08-20

    By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

  13. Scheme for improving laser stability via feedback control of intracavity nonlinear loss.

    Science.gov (United States)

    Jin, Pixian; Lu, Huadong; Su, Jing; Peng, Kunchi

    2016-05-01

    We present a novel and efficient scheme to enhance the stability of laser output via feedback control to a nonlinear loss deliberately introduced to the laser resonator. By means of the feedback control to the intracavity nonlinear loss of an all-solid-state continuous-wave single-frequency laser with high output power at 1064 nm, its intensity and frequency stabilities are significantly improved. A lithium triborate crystal is deliberately placed inside the laser resonator to be an element of the nonlinear loss, and the temperature of the crystal is feedback controlled by an electronic loop. The control signal is generated by distinguishing the deviation of the output power and used for manipulating the intracavity nonlinear loss to compensate the deviation of the laser power actively. With the feedback-control loop, the intensity and frequency fluctuations of the output laser at 1064 nm are reduced from ±0.59% and 21.82 MHz without the feedback to ±0.26% and 9.84 MHz, respectively.

  14. Experiments of Laser Pointing Stability in Air and in Vacuum to Validate Micrometric Positioning Sensor

    CERN Document Server

    Stern, G; Piedigrossi, D; Sandomierski, J; Sosin, M; Geiger, A; Guillaume, S

    2014-01-01

    Aligning accelerator components over 200m with 10 μm accuracy is a challenging task within the Compact Linear Collider (CLIC) study. A solution based on laser beam in vacuum as straight line reference is proposed. The positions of the accelerator’s components are measured with respect to the laser beam by sensors made of camera/shutter assemblies. To validate these sensors, laser pointing stability has to be studied over 200m. We perform experiments in air and in vacuum in order to know how laser pointing stability varies with the distance of propagation and with the environment. The experiments show that the standard deviations of the laser spot coordinates increase with the distance of propagation. They also show that the standard deviations are much smaller in vacuum (8 μm at 35m) than in air (2000 μm at 200m). Our experiment validates the concept of laser beam in vacuum with camera/shutter assembly for micrometric positioning over 35m. It also gives an estimation of the achievable precision.

  15. Phase stability of photoreceivers in intersatellite laser interferometers.

    Science.gov (United States)

    Barranco, Germán Fernández; Gerberding, Oliver; Schwarze, Thomas S; Sheard, Benjamin S; Dahl, Christian; Zender, Bernd; Heinzel, Gerhard

    2017-04-03

    A photoreceiver (PR) is required for the opto-electrical conversion of signals in intersatellite laser interferometers. Noise sources that originate or couple in the PR reduce the system carrier-to-noise-density, which is often represented by its phase noise density. In this work, we analyze the common noise sources in a PR used for space-based interferometry. Additionally, we present the results from the characterization of the PRs in GRACE-FO, a mission which will pioneer intersatellite laser interferometry. The estimated phase noise is shot-noise limited at 10-4 rad/Hz1/2 down to 10-2 Hz, almost 4 orders of magnitude below the instrument top level requirement (0.5 rad/Hz1/2). Below 10-2 Hz, the PR finite phase response noise dominates but the levels still comply with the instrument requirement. The sub-mHz noise levels and the PR electronic noise have been identified as key design factors for the LISA PR.

  16. Laser driven thermal reactor for hazardous waste stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Nazarian, A. [SAIC, Germantown, MD (United States)

    1996-12-31

    Increasing attention is being paid to treatment of hazardous waste through stabilization and possible solidification. Among the preferred technologies are thermal processes that detoxify and reduce the volume of hazardous wastes by exposing them to appropriate thermal regimes. However, as with any technology, there are potential problems which may detract from the application of the technology. Environmental pollution from particulate matter and off-gases can occur. Therefore, it is important to develop the technology of hazardous waste stabilization on a strong research base and to determine parameters and conditions of appropriate thermal processes. The purpose of the present work was to determine phenomenological parameters that characterize the processes of hazardous waste stabilization during thermal treatment. These methods can be used for any kind of liquid, solid and multiphase (liquid/solid and gas/solid) hazardous wastes. The method presented herein has been used to find corresponding parameters and conditions in the following applications: decomposition of ozone and nitrocompounds absorbed by activated carbon; sulphur compounds in heavy fuel oil; and appraisals of the explosion hazards involved in coal mining.

  17. Effects of low-level laser therapy on mast cell number and degranulation in third-degree burns of rats.

    Science.gov (United States)

    Bayat, Mohammad; Vasheghani, Mohammad Mehdi; Razavie, Naser; Jalili, Mohammad Reza

    2008-01-01

    Mast cells have been shown to participate in the wound healing process. We investigated the effects of low-level laser therapy (LLLT) on mast cell number in the inflammation, proliferation, and remodeling phases of the wound healing process of experimental burns. Sixty rats subjected to third-degree burns were divided into four groups: two laser-treated, one control, and one nitrofurazone-treated group. In the two laser-treated groups, burned areas received LLLT with a helium-neon laser at energy densities of 38.2 J/cm(2) and 76.4 J/cm(2), respectively. The effects on mast cell number and degranulation were assessed 7, 16, and 30 days postburn (inflammation, proliferation, and remodeling phases of wound healing, respectively). Intact and degranulated mast cells were counted. Five rats with no burns were used for baseline studies. On day 7 in the first laser group, the total number of mast cells was significantly higher than in the other groups. On day 16 in the nitrofurazone-treated group, the total number of mast cells was significantly higher than in the control, first laser, and normal groups. LLLT on the experimental third-degree burns significantly increased the total number of mast cells during the inflammation phase of wound healing; also, topical application of 0.2% nitrofurazone ointment on the same burns significantly increased the total number of mast cells during the proliferation phase of burn healing.

  18. Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Cavity Length

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Radek; Číp, Ondřej; Čížek, Martin; Mikel, Břetislav; Lazar, Josef

    2010-01-01

    Roč. 57, č. 3 (2010), s. 636-640 ISSN 0885-3010 R&D Projects: GA ČR GA102/09/1276; GA MŠk(CZ) LC06007; GA MŠk 2C06012; GA MPO 2A-1TP1/127; GA MPO FT-TA3/133; GA MPO 2A-3TP1/113; GA ČR GA102/07/1179 Institutional research plan: CEZ:AV0Z20650511 Keywords : laser * Fabry-Perot * interferometer * length etalon Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.460, year: 2010

  19. Stability diagrams for continuous wide-range control of two mutually delay-coupled semiconductor lasers

    Science.gov (United States)

    Junges, Leandro; Gallas, Jason A. C.

    2015-05-01

    The dynamics of two mutually delay-coupled semiconductor lasers has been frequently studied experimentally, numerically, and analytically either for weak or strong detuning between the lasers. Here, we present a systematic numerical investigation spanning all detuning ranges. We report high-resolution stability diagrams for wide ranges of the main control parameters of the laser, as described by the Lang-Kobayashi model. In particular, we detail the parameter influence on dynamical performance and map the distribution of chaotic pulsations and self-generated periodic spiking with arbitrary periodicity. Special attention is given to the unfolding of regular pulse packages for both symmetric and non-symmetric configurations with respect to detuning. The influence of the delay -time on the self-organization of periodic and chaotic laser phases as a function of the coupling and detuning is also described in detail.

  20. Experiment of Laser Pointing Stability on Different Surfaces to validate Micrometric Positioning Sensor

    CERN Document Server

    AUTHOR|(SzGeCERN)721924; Mainaud Durand, Helene; Piedigrossi, Didier; Sandomierski, Jacek; Sosin, Mateusz; Geiger, Alain; Guillaume, Sebastien

    2014-01-01

    CLIC requires 10 μm precision and accuracy over 200m for the pre-alignment of beam related components. A solution based on laser beam as straight line reference is being studied at CERN. It involves camera/shutter assemblies as micrometric positioning sensors. To validate the sensors, it is necessary to determine an appropriate material for the shutter in terms of laser pointing stability. Experiments are carried out with paper, metal and ceramic surfaces. This paper presents the standard deviations of the laser spot coordinates obtained on the different surfaces, as well as the measurement error. Our experiments validate the choice of paper and ceramic for the shutter of the micrometric positioning sensor. It also provides an estimate of the achievable precision and accuracy of the determination of the laser spot centre with respect to the shutter coordinate system defined by reference targets.

  1. Stability of a short Rayleigh length laser resonator

    Directory of Open Access Journals (Sweden)

    P. P. Crooker

    2005-04-01

    Full Text Available Motivated by the prospect of constructing a short Rayleigh length free-electron laser in a high-vibration environment, we demonstrate the use of a collection of rays to study the effect of mirror vibration and distortion on the behavior of the fundamental optical mode of a cold-cavity resonator. We find that the ray collection accurately describes both on-axis and off-axis optical beams. We show that a tilt or transverse shift of a mirror causes the optical mode to rock about the original resonator axis, while a longitudinal mirror shift or a change in the mirror’s radius of curvature causes the beam diameter at a mirror to successively dilate and contract on the mirror. Results are in excellent agreement with analytic calculations and wave front propagation simulations as long as the mirrors remain large with respect to the beam diameter.

  2. Stabilized diode seed laser for flight and space-based remote lidar sensing applications

    Science.gov (United States)

    McNeil, Shirley; Pandit, Pushkar; Battle, Philip; Rudd, Joe; Hovis, Floyd

    2017-08-01

    AdvR, through support of the NASA SBIR program, has developed fiber-based components and sub-systems that are routinely used on NASA's airborne missions, and is now developing an environmentally hardened, diode-based, locked wavelength, seed laser for future space-based high spectral resolution lidar applications. The seed laser source utilizes a fiber-coupled diode laser, a fiber-coupled, calibrated iodine reference module to provide an absolute wavelength reference, and an integrated, dual-element, nonlinear optical waveguide component for second harmonic generation, spectral formatting and wavelength locking. The diode laser operates over a range close to 1064.5 nm, provides for stabilization of the seed to the desired iodine transition and allows for a highly-efficient, fully-integrated seed source that is well-suited for use in airborne and space-based environments. A summary of component level environmental testing and spectral purity measurements with a seeded Nd:YAG laser will be presented. A direct-diode, wavelength-locked seed laser will reduce the overall size weight and power (SWaP) requirements of the laser transmitter, thus directly addressing the need for developing compact, efficient, lidar component technologies for use in airborne and space-based environments.

  3. High power conversion efficiency and wavelength-stabilized narrow bandwidth 975nm diode laser pumps

    Science.gov (United States)

    Kanskar, M.; Cai, J.; Galstad, C.; He, Y.; Macomber, S. H.; Stiers, E.; Tatavarti-Bharatam, S. R.; Botez, D.; Mawst, L. J.

    2006-05-01

    We report on improvement from 50% to 70% power conversion efficiency on a 5-bar stack with 500 W of CW power at 25C coolant temperature resulting from a multi-pronged optimization approach. We also report on wavelength stabilization (0.07 nm/C) and emission bandwidth narrowing (0.3 nm at FWHM) of diode laser pump sources for precision pumping the upper transition levels of lasers that require narrow and stable pump sources such as Er/Yb co-doped or Yb:YAG lasers. These results have been achieved by integration of a Bragg grating inside a semiconductor laser cavity forming a low-loss, weak distributed feedback (DFB) laser, which results in record 53% wall-plug efficiency at 3 W CW operation and 25°C heatsink temperature from a 100-μm aperture diode laser and 45 W of wavelength-locked CW power from a 20% fill factor bar. This technique can be readily applied to diode laser structures for other strategic pump wavelengths.

  4. Stability study for matching in laser driven plasma acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, A.R., E-mail: andrea.rossi@mi.infn.it [INFN - MI, via Celoria 16, 20133 Milan (Italy); Anania, M.P. [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Bacci, A. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Belleveglia, M.; Bisesto, F.G.; Chiadroni, E. [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Cianchi, A. [Tor Vergata University, Physics Department, via della Ricerca Scientifica 1, 00133 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Curcio, A.; Gallo, A.; Di Giovenale, D.; Di Pirro, G.; Ferrario, M. [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Marocchino, A.; Massimo, F. [La Sapienza University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); Mostacci, A. [La Sapienza University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Petrarca, M. [La Sapienza University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); Pompili, R. [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Serafini, L. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Tomassini, P. [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); Vaccarezza, C. [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); and others

    2016-09-01

    In a recent paper [14], a scheme for inserting and extracting high brightness electron beams to/from a plasma based acceleration stage was presented and proved to be effective with an ideal bi-Gaussian beam, as could be delivered by a conventional photo-injector. In this paper, we extend that study, assessing the method stability against some jitters in the properties of the injected beam. We find that the effects of jitters in Twiss parameters are not symmetric in results; we find a promising configuration that yields better performances than the setting proposed in [14]. Moreover we show and interpret what happens when the beam charge profiles are modified.

  5. Edge-emitting InGaAs/GaAs laser with high temperature stability of wavelength and threshold current

    International Nuclear Information System (INIS)

    Gordeev, N Yu; Novikov, I I; Chunareva, A V; Il'inskaya, N D; Shernyakov, Yu M; Maximov, M V; Kalyuzhnyy, N A; Mintairov, S A; Lantratov, V M; Payusov, A S; Shchukin, V A; Ledentsov, N N

    2010-01-01

    We have investigated an edge-emitting tilted wave laser (TWL) with the active region based on GaInAs/GaAs quantum wells. In the TWL the wavelength stabilization is based on the coupling of the laser active waveguide cavity to a specially introduced thick epitaxial layer and the emission wavelength is defined by the combined cavity mode preferably by a single dominating mode. The TWL wafer has been grown by metal-organic chemical vapour deposition. Laser parameters have been investigated both in pulsed and CW mode in the temperature range of 15–60 °C. In the temperature window of 20–50 °C under CW excitation the lasers have shown high wavelength temperature stability with the temperature shift of 0.05 nm K −1 and threshold current stability with the characteristic temperature of 500 K. The data obtained prove the concept of thermal stability in tilted wave lasers

  6. Cryogenic Yb:YAG laser pumped by VBG-stabilized narrowband laser diode at 969 nm

    Czech Academy of Sciences Publication Activity Database

    Jambunathan, Venkatesan; Horáčková, Lucie; Navrátil, Petr; Lucianetti, Antonio; Mocek, Tomáš

    2016-01-01

    Roč. 128, č. 12 (2016), s. 1328-1331 ISSN 1041-1135 R&D Projects: GA MŠk EE2.3.20.0143; GA ČR GA14-01660S Grant - others:HILASE(XE) CZ.1.05/2.1.00/01.0027; HILASE(XE) CZ.1.05/2.1.00/01.0027; OP VK 6(XE) CZ.1.07/2.3.00/20.0143 Institutional support: RVO:68378271 Keywords : Diode-pumped * cryogenic * volume Bragg grating * Yb doped * solid state lasers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.375, year: 2016

  7. Edge-emitting lasers based on coupled large optical cavity with high beam stability

    Science.gov (United States)

    Serin, A.; Gordeev, N.; Payusov, A.; Shernyakov, Y.; Kalyuzhnyy, y.; Mintairov, S.; Maximov, M.

    2017-11-01

    In this paper we present a study on temperature and current stability of far-field patterns of lasers based on the coupled large optical cavity (CLOC) concept. Previously it has been shown that the CLOC structures allows effective suppressing of high-order mode lasing in broadened waveguides. For the first time we report on transverse single-mode emission from the CLOC lasers with 4.8 μm thick waveguide. Using broadened waveguide allowed us to reduce the divergence of the far-field patterns down to 14° in continuous-wave (CW) regime. Far-field patterns proved to be insensitive to current and temperature changes.

  8. Contribution of thermal noise to frequency stability of rigid optical cavity via Hertz-linewidth lasers

    International Nuclear Information System (INIS)

    Notcutt, Mark; Ma, L.-S.; Ludlow, Andrew D.; Foreman, Seth M.; Ye Jun; Hall, John L.

    2006-01-01

    We perform detailed studies of state-of-the-art laser stabilization to high finesse optical cavities, revealing fundamental mechanical thermal noise-related length fluctuations. We compare the frequency noise of lasers tightly locked to the resonances of a variety of rigid Fabry-Perot cavities of differing lengths and mirror substrate materials. The results are in agreement with the theoretical model proposed in K. Numata, A. Kemery, and J. Camp [Phys. Rev. Lett. 93, 250602 (2004)]. The results presented here on the fundamental limits of FP references will impact planning and construction of next generation ultrastable optical cavities

  9. Changes in Cell Viability of Wounded Fibroblasts following Laser Irradiation in Broad-Spectrum or Infrared Light

    International Nuclear Information System (INIS)

    Hawkins, D.; Abrahamse, H.

    2007-01-01

    Objective. This study aimed to establish if broad-spectrum or infrared (IR) light in combination with laser therapy can assist phototherapy to improve the cell function of wounded cells. Background. The effect of laser light may be partly or completely reduced by broad-spectrum light. Methods. Wounded human skin fibroblasts were irradiated with 5 J/cm2 using a helium-neon laser, a diode laser, or an Nd:YAG laser in the dark, in the light, or in IR. Changes in cell viability were evaluated by cell morphology, ATP cell viability, LDH membrane integrity, and caspase 3/7 as an early marker of apoptosis. Results. Wounded cells exposed to 5 J/cm2 using 632.8 nm in the dark or 830 nm in the light or 1064 nm in the dark showed an increase in ATP viability, an increase in cytokine expression, and a decrease in LDH cytotoxicity indicating that the metabolic activity of the wounded cells was stimulated. Conclusion. Wounded cells irradiated in IR light showed an undesirable thermal effect that was proportional to the duration of exposure.

  10. Laser source for dimensional metrology: investigation of an iodine stabilized system based on narrow linewidth 633 nm DBR diode

    Czech Academy of Sciences Publication Activity Database

    Řeřucha, Šimon; Yacoot, A.; Pham, Minh Tuan; Čížek, Martin; Hucl, Václav; Lazar, Josef; Číp, Ondřej

    2017-01-01

    Roč. 28, č. 4 (2017), s. 1-11, č. článku 045204. ISSN 0957-0233 R&D Projects: GA ČR GB14-36681G; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA TA ČR TE01020233 Institutional support: RVO:68081731 Keywords : optical metrology * DBR laser diode * frequency stabilization * laser interferometry * dimensional metrology * iodine stabilization * displacement measurement Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.585, year: 2016

  11. Performance of resonator fiber optic gyroscope using external-cavity laser stabilization and optical filtering

    Science.gov (United States)

    Qiu, Tiequn; Wu, Jianfeng; Strandjord, Lee K.; Sanders, Glen A.

    2014-05-01

    A bench-top resonator fiber optic gyroscope (RFOG) was assembled and tested, showing encouraging progress toward navigation grade performance. The gyro employed a fiber length of 19 meters of polarizing fiber for the sensing coil which was wound on an 11.5 cm diameter PZT cylinder. A bias stability of approximately 0.1 deg/hr was observed over a 2 hour timeframe, which is the best bias stability reported to date in an RFOG to our knowledge. Special care was taken to minimize laser phase noise, including stabilization to an optical cavity which was also used for optical filtering, giving angle random walk (ARW) values in the range of 0.008 deg/rt-hr. The ARW performance and bias stability are within 2x and 10x, respectively, of many civil inertial navigation grade requirements.

  12. Study of fuzzy adaptive PID controller on thermal frequency stabilizing laser with double longitudinal modes

    Science.gov (United States)

    Mo, Qingkai; Zhang, Tao; Yan, Yining

    2016-10-01

    There are contradictions among speediness, anti-disturbance performance, and steady-state accuracy caused by traditional PID controller in the existing light source systems of thermal frequency stabilizing laser with double longitudinal modes. In this paper, a new kind of fuzzy adaptive PID controller was designed by combining fuzzy PID control technology and expert system to make frequency stabilizing system obtain the optimal performance. The experiments show that the frequency stability of the designed PID controller is similar to the existing PID controller (the magnitude of frequency stability is less than 10-9 in constant temperature and 10-7 in open air). But the preheating time is shortened obviously (from 10 minutes to 5 minutes) and the anti-disturbance capability is improved significantly (the recovery time needed after strong interference is reduced from 1 minute to 10 seconds).

  13. Thermal stability of multi-longitudinal mode laser beating frequencies in hybrid semiconductor-fiber ring lasers

    Science.gov (United States)

    Shebl, Ahmed; Hassan, Khaled; Al-Arifi, Fares; Al-Otaibi, Mohammed; Sabry, Yasser; Khalil, Diaa

    2015-03-01

    The temperature dependence of the beating frequencies in multi-longitudinal mode hybrid semiconductor-fiber based ring lasers is studied theoretically and experimentally. The variation of the beating frequency with temperature is found to be smaller for larger cavity length and lower beating order. Measured frequency variation as low as -0.24 Hz/°C is obtained for cavity length of 2.7 km. The stability of the frequency is evaluated using the Allan variance technique. The measurement is carried out for different beating frequency orders. The lowest order beating frequency has about 20x better long-term frequency stability than the beating frequency of the 100th order.

  14. Characterization of Environmental Stability of Pulsed Laser Deposited Oxide Ceramic Coatings

    Energy Technology Data Exchange (ETDEWEB)

    ADAMS, THADM

    2004-03-02

    A systematic investigation of candidate hydrogen permeation materials applied to a substrate using Pulsed Laser Deposition has been performed. The investigation focused on application of leading permeation-resistant materials types (oxide, carbides, and metals) on a stainless steel substrate. and evaluation of the stability of the applied coatings. Type 304L stainless steel substrates were coated with aluminum oxide, chromium oxide, and aluminum. Characterization of the coating-substrate system adhesion was performed using scratch adhesion testing and microindentation. Coating stability and environmental susceptibility were evaluated for two conditions-air at 350 degrees Celsius and Ar-H2 at 350 degrees Celsius for up to 100 hours. Results from this study have shown the pulsed laser deposition process to be an extremely versatile technology that is capable of producing a sound coating/substrate system for a wide variety of coating materials.

  15. High passive-stability diode-laser design for use in atomic-physics experiments

    Science.gov (United States)

    Cook, Eryn C.; Martin, Paul J.; Brown-Heft, Tobias L.; Garman, Jeffrey C.; Steck, Daniel A.

    2012-04-01

    We present the design and performance characterization of an external-cavity diode-laser system optimized for high stability, low passive spectral linewidth, low cost, and ease of in-house assembly. The main cavity body is machined from a single aluminum block for robustness to temperature changes and mechanical vibrations, and features a stiff and light diffraction-grating arm to suppress low-frequency mechanical resonances. The cavity is vacuum sealed, and a custom-molded silicone external housing further isolates the system from acoustic noise and temperature fluctuations. Beam shaping, optical isolation, and fiber coupling are integrated, and the design is easily adapted to many commonly used wavelengths. Resonance data, passive-linewidth data, and passive stability characterization of the new design demonstrate that its performance exceeds published specifications for commercial precision diode-laser systems. The design is fully documented and freely available.

  16. Aeolus high energy UV Laser wavelength measurement and frequency stability analysis

    Science.gov (United States)

    Mondin, Linda; Bravetti, Paolo

    2017-11-01

    The Aeolus mission is part of ESA's Earth Explorer program. The goal of the mission is to determine the first global wind data set in near real time to improve numerical weather prediction models. The only instrument on board Aeolus, Aladin, is a backscatter wind LIDAR in the ultraviolet (UV) frequency domain. Aeolus is a frequency limited mission, inasmuch as it relies on the measure of the backscattered signal frequency shift in order to deduce the wind velocity. As such the frequency stability of the LIDAR laser source is a key parameter for this mission. In the following, the characterization of the laser frequency stability, reproducibility and agility in vacuum shall be reported and compared to the mission requirements.

  17. Increased stability in laser metal wire deposition through feedback from optical measurements

    Science.gov (United States)

    Heralić, Almir; Christiansson, Anna-Karin; Ottosson, Mattias; Lennartson, Bengt

    2010-04-01

    Robotized laser metal-wire deposition is a fairly new technique being developed at University West in cooperation with Swedish industry for solid freeform fabrication of fully densed metal structures. It is developed around a standard welding cell and uses robotized fiber laser welding and wire filler material together with a layered manufacturing method to create metal structures. In this work a monitoring system, comprising two cameras and a projected laser line, is developed for on-line control of the deposition process. The controller is a combination of a PI-controller for the bead width and a feed-forward compensator for the bead height. It is evaluated through deposition of single-bead walls, and the results show that the process stability is improved when the proposed controller is used.

  18. Michelson mode selector for spectral range stabilization in a self-sweeping fiber laser.

    Science.gov (United States)

    Tkachenko, A Yu; Vladimirskaya, A D; Lobach, I A; Kablukov, S I

    2018-04-01

    We report on spectral range stabilization in a self-sweeping laser by adding a narrowband fiber Bragg grating (FBG) to the output mirror in the Michelson configuration. The effects of FBG reflectivity and optical path difference in the Michelson interferometer on the laser spectral dynamics are investigated. Optimization of the interferometer allows us to demonstrate broadband (over 16 nm) self-sweeping operation and reduction of the start and stop wavelength fluctuations by two orders and one order of magnitude (∼100 and 15 times) for start and stop bounds, respectively (down to several picometers). The proposed approaches significantly improve quality of the spectral dynamics and facilitate application of the self-sweeping lasers.

  19. A stabilized optical frequency comb based on an Er-doped fiber femtosecond laser

    Science.gov (United States)

    Xia, Chuanqing; Wu, Tengfei; Zhao, Chunbo; Xing, Shuai

    2018-03-01

    An optical frequency comb based on a 250 MHz home-made Er-doped fiber femtosecond laser is presented in this paper. The Er-doped fiber laser has a ring cavity and operates mode-locked in femtosecond regime with the technique of nonlinear polarization rotation. The pulse duration is 118 fs and the spectral width is 30 nm. A part of the femtosecond laser is amplified in Er-doped fiber amplifier before propagating through a piece of highly nonlinear fiber for expanding the spectrum. The carrier-envelope offset frequency of the comb which has a signal-to-noise ratio more than 35 dB is extracted by means of f-2f beating. It demonstrates that both carrier-envelope offset frequency and repetition frequency keep phase locked to a Rubidium atomic clock simultaneously for 2 hours. The frequency stabilized fiber combs will be increasingly applied in optical metrology, attosecond pulse generation, and absolute distance measurement.

  20. A laser scanner for imaging fluorophore labeled molecules in electrophoretic gels

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, D.J.; Sutherland, J.C. [Brookhaven National Lab., Upton, NY (United States). Biology Dept.

    1995-08-01

    A laser scanner for imaging electrophoretic gels was constructed and tested. The scanner incorporates a green helium-neon (HeNe) laser (543.5nm wavelength) and can achieve a spatial resolution of 19{micro}m. The instrument can function in two modes : snap-shot and finish-line. In snapshot mode, all samples are electrophoresed for the same time and the gel is scanned after completion of electrophoresis, while in finish-line mode, fluorophore labeled samples are electrophoresed for a constant distance and the image is formed as the samples pass under the detector. The resolving power of the finish-line mode of imaging is found to be greater than that of the snapshot mode of imaging. This laser scanner is also compared with a Charge Coupled Device (CCD) camera and in terms of resolving power is found to be superior. Sensitivity of the instrument is presented in terms of the minimum amount of DNA that can be detected verses its molecular length.

  1. Evaluation of the tear film stability after laser in situ keratomileusis using the tear film stability analysis system.

    Science.gov (United States)

    Goto, Tomoko; Zheng, Xiaodong; Klyce, Stephen D; Kataoka, Hisashi; Uno, Toshihiko; Yamaguchi, Masahiko; Karon, Mike; Hirano, Sumie; Okamoto, Shigeki; Ohashi, Yuichi

    2004-01-01

    To evaluate the tear film stability of patients before and after laser in situ keratomileusis (LASIK) using the tear film stability analysis system (TSAS). Prospective observational case series. New videokeratography software for a topographic modeling system (TMS-2N) was developed that can automatically capture consecutive corneal surface images every second for 10 seconds. Thirty-four subjects (64 eyes) who underwent myopia LASIK were enrolled in this study. All subjects were examined with the new system before LASIK and at 1 week, 1 month, 3 months, and 6 months after the surgery. Corneal topographs were analyzed for tear breakup time (TMS breakup time) and breakup area (TMS breakup area). Based on pre-LASIK TSAS analysis, subjects were separated into normal and abnormal TSAS value groups. The criteria for the normal group were either TMS breakup time more than 5 seconds or TMS breakup area less than 0.2. The percentage of the occurrence of superficial punctuate keratitis was compared between the two groups with regard to subject's dry eye signs and symptoms. Tear film stability decreased significantly during the early period after LASIK, as indexed by decreased TMS breakup time and increased TMS breakup area. Tear film instability resolved at 6 months after surgery. Before LASIK, 22 subjects (43 eyes) had normal TSAS evaluation and 12 subjects (21 eyes) were abnormal. After LASIK, among normal TSAS value eyes, 8 of 43 (18.6%) eyes developed superficial punctuate keratitis. In sharp contrast, 14 of 21 (66.7%) eyes in the abnormal group displayed superficial punctuate keratitis, correlating well with the patients' dry eye symptoms. The difference in the presence of superficial punctuate keratitis after LASIK between normal and abnormal TSAS value groups was statistically significant (P <.001). Subjects with abnormal TSAS evaluation also displayed resistance to dry eye treatment and had extended period of recovery. Tear film stability analysis can be a useful

  2. Frequency stabilization of ambience-isolated internal-mirror He-Ne lasers by thermoelectric-cooling thermal compensation

    Science.gov (United States)

    Shirvani-Mahdavi, Hamidreza; Narges, Yaghoubi

    2016-12-01

    An approach for frequency stabilization of an ambience-isolated internal-mirror He-Ne laser (632.8 nm) utilizing temperature control of the laser tube with Peltier thermoelectric coolers is demonstrated. Measurements indicate that there are an optimal temperature (23 °C) and an optimal discharge current (5.5 mA) of laser tube for which the laser light power is separately maximized. To prevent the effect of fluctuation of discharge current on the laser stability, an adjustable current source is designed and fabricated so that the current is set to be optimal (5.50 ± 0.01 mA). To isolate the laser tube from the environment, the laser metallic box connected to two Peltier thermoelectric coolers is surrounded by two thermal and acoustic insulator shells. The laser has two longitudinal modes very often. Any change in the frequency of longitudinal modes at the optimal temperature is monitored by sampling the difference of longitudinal modes' intensities. Therefore, using a feedback mechanism, the current of thermoelectric coolers is so controlled that the frequency of modes stays constant on the gain profile of the laser. The frequency stability is measured equal to 1.17 × 10-9 (˜2700×) for less than 1 min and 2.57 × 10-9 (˜1200×) for more than 1 h.

  3. Reliable Operation for 14500 h of a Wavelength-Stabilized Diode Laser System on a Microoptical Bench at 671 nm

    DEFF Research Database (Denmark)

    Sumpf, Bernd; Maiwald, Martin; Müller, André

    2012-01-01

    Reliability tests for wavelength-stabilized compact diode laser systems emitting at 671 nm are presented. The devices were mounted on microoptical benches with the dimensions of 13 mm $\\times\\,$4 mm. Reflecting Bragg gratings were used for wavelength stabilization and emission width narrowing...

  4. Inducing myoblast re-entry into the cell cycle: a potential mechanism for laser-enhanced skeletal muscle regeneration

    Science.gov (United States)

    Liu, T.; Fang, Y.; Zhang, C. P.; Chen, P.; Wang, C. Z.; Kang, H. X.; Shen, B. J.; Liang, J.; Fu, X. B.

    2014-09-01

    This study investigated the effect of low-level laser irradiation (LLLI) on the cell cycle and proliferative activity of cultured myoblasts, and sought to elucidate the possible cellular mechanism by which LLLI promotes the regeneration of skeletal muscle in vivo. Primary myoblasts isolated from rat hindlegs were irradiated with helium-neon laser light at different energy densities. Distributions of cell-cycle subpopulations and the expression of cell-cycle regulatory proteins in myoblasts were assessed using flow cytometric analysis and western blot assay. It was found that laser irradiation stimulated cell-cycle entry; induced the expression of cyclin A and cyclin D; and increased cell proliferation index and bromodeoxyuridine incorporation as compared to the unirradiated control cells, indicating LLLI augmented the number of proliferative myoblasts in the S phase and G2/M phase of the cell cycle. These results suggest that LLLI at certain fluxes and wavelengths could activate quiescent myoblasts, leading to cell division and facilitating new myofiber formation. This could contribute to the improvement of skeletal muscle regeneration following trauma and myopathic diseases.

  5. THE DETERMINATION OF A CRITICAL VALUE FOR DYNAMIC STABILITY OF SEMICONDUCTOR LASER DIODE WITH EXTERNAL OPTICAL FEEDBACK

    Directory of Open Access Journals (Sweden)

    Remzi YILDIRIM

    1998-01-01

    Full Text Available In this study, dynamic stability analysis of semiconductor laser diodes with external optical feedback has been realized. In the analysis the frequency response of the transfer function of laser diode H jw( , the transfer m function of laser diode with external optical feedback TF jw( , and optical feedback transfer function m K jw( obtained from small signal equations has been m accomplished using Nyquist stability analysis in complex domain. The effect of optical feedback on the stability of the system has been introduced and to bring the laser diode to stable condition the working critical boundary range of dampig frequency and reflection power constant (R has been determined. In the study the reflection power has been taken as ( .

  6. Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS).

    Science.gov (United States)

    Hardin, Robert A; Liu, Yun; Long, Cary; Aleksandrov, Alexander; Blokland, Willem

    2011-02-14

    A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 μrad (horizontal) to 4 μrad (vertical), corresponding to beam drifts of only 0.5 mm × 1 mm at the furthest measurement station located 250 meters away from the light source.

  7. Laser beam pointing and stabilization by fractional-order PID control: Tuning rule and experiments

    KAUST Repository

    Al-Alwan, Asem Ibrahim Alwan

    2017-10-24

    This paper studies the problem of high-precision positioning of laser beams by using a robust Fractional-Order Proportional-Integral-Derivative (FOPID) controller. The control problem addressed in laser beams aims to maintain the position of the laser beam on a Position Sensing Device (PSD) despite the effects of noise and active disturbances. The FOPID controller is well known for its simplicity with better tuning flexibility along with robustness to noise and output disturbance rejections. Thus, a control strategy based on FOPID to achieve the control objectives has been proposed. The FOPID gains and differentiation orders are optimally tuned in order to fulfill the robustness design specifications by solving a nonlinear optimization problem. A comparison to the conventional Proportional-Integral-Derivative (PID) and robust PID is also provided from simulation and experiment set-up. Due to sensor noise, practical PID controllers that filter the position signal before taking the derivative have been also proposed. Experimental results show that the requirements are totally met for the laser beam platform to be stabilized.

  8. Laser aided direct metal deposition of Inconel 625 superalloy: Microstructural evolution and thermal stability

    International Nuclear Information System (INIS)

    Dinda, G.P.; Dasgupta, A.K.; Mazumder, J.

    2009-01-01

    Direct metal deposition technology is an emerging laser aided manufacturing technology based on a new additive manufacturing principle, which combines laser cladding with rapid prototyping into a solid freeform fabrication process that can be used to manufacture near net shape components from their CAD files. In the present study, direct metal deposition technology was successfully used to fabricate a series of samples of the Ni-based superalloy Inconel 625. A high power CO 2 laser was used to create a molten pool on the Inconel 625 substrate into which an Inconel 625 powder stream was delivered to create a 3D object. The structure and properties of the deposits were investigated using optical and scanning electron microscopy, X-ray diffraction and microhardness test. The microstructure has been found to be columnar dendritic in nature, which grew epitaxially from the substrate. The thermal stability of the dendritic morphology was investigated in the temperature range 800-1200 deg. C. These studies demonstrate that Inconel 625 is an attractive material for laser deposition as all samples produced in this study are free from relevant defects such as cracks, bonding error and porosity.

  9. Resonator stability and higher-order modes in free-electron laser oscillators

    Directory of Open Access Journals (Sweden)

    Abhishek Pathak

    2014-08-01

    Full Text Available Three-dimensional simulation codes genesis and opc are used to investigate the dependence of the resonator stability of free-electron laser (FEL oscillators on the stability parameter, laser wavelength, outcoupling hole size and mirror tilt. We find that to have stable lasing over a wide range of wavelengths, the FEL cavity configuration should be carefully chosen. Broadly, the concentric configuration gives near-Gaussian modes and the best performance. At intermediate configurations the dominant mode often switches to a higher-order mode, which kills lasing. For the same reason, the outcoupled power can also be less. We have constructed a simple analytic model to study resonator stability which gives results that are in excellent agreement with the simulations. This suggests that modes in FEL oscillators are determined more by the cavity configuration and radiation propagation than by the details of the FEL interaction. We find (as in experiments at the CLIO FEL that tilting the mirror can, for some configurations, lead to more outcoupled power than a perfectly aligned mirror because the mode is now a more compact higher-order mode, which may have implications for the mode quality for user experiments. Finally, we show that the higher-order mode obtained is usually a single Gauss-Laguerre mode, and therefore it should be possible to filter out the mode using suitable intracavity elements, leading to better FEL performance.

  10. On the way to stabilized laser-driven GeV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Shao-wei; Weineisen, Tobias; Fuchs, Matthias; Popp, Antonia; Major, Zsuzsanna; Weingartner, Raphael; Ahmad, Izhar; Schmid, Karl; Marx, Benjamin; Krausz, Ferenc; Gruener, Florian; Karsch, Stefan [Max-Planck Institute of Quantum Optics, Munich (Germany); Ludwig-Maximilians University, Munich (Germany); Osterhoff, Jens [LOASIS Program, Lawrence Livermore National Laboratory, Livermore (United States); Schroeder, Hartmut; Haas, Harald [Max-Planck Institute of Quantum Optics, Munich (Germany); Rowlands-Rees, Tom; Hooker, Simon [University of Oxford, Oxford (United Kingdom)

    2010-07-01

    Laser-driven-wakefield electron accelerators have shown electron beams with energies of up to 1 GeV from a centimeter-scale plasma accelerator. In order to achieve higher electron energies, these acceleration distances need to be increased. This can be realized with a discharge capillary. However, a discharge typically introduces instabilities on both pointing and energy of the generated electrons. In order to improve the stability, we demonstrate a preliminary test of a modified discharge which includes a pre-pulse circuit before the firing of the main pulse. We also show gas density shaping by a laser- machined nozzle which should be able to make a more precise injection in the capillary accelerator thus reducing the energy instability.

  11. Beam stability and warm-up effects of Nd:YAG lasers used in particle image velocimetry

    International Nuclear Information System (INIS)

    Grayson, K; De Silva, C M; Hutchins, N; Marusic, I

    2017-01-01

    The characteristics and causes of Nd:YAG laser warm-up transients and steady state beam stability effects are investigated in this study. Dynamic laser performance has a particularly noticeable impact on particle image velocimetry (PIV) and other laser-based flow visualisation techniques, where changes in beam pointing can influence the overlap between laser light sheets and thereby degrade the correlation of PIV image pairs. Despite anecdotal knowledge or experience of laser warm-up effects, they have not been formally documented or quantified to date for PIV applications. In this study, the nature of these laser transients are analysed and compared among a selection of typical PIV laser equipment. An investigation into the cause of these transients during the laser warm-up sequence is also presented. Furthermore, the degree of dual cavity transient coupling within a PIV laser system is analysed to determine a practical limit to the laser light sheet overlap that can be expected from PIV experiments. Finally, the results from this study inform a series of recommendations for PIV best practice, which aim to minimise the impact of laser transients on experimental data. (paper)

  12. Aqueous starch as a stabilizer in zinc oxide nanoparticle synthesis via laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Zamiri, Reza; Zakaria, Azmi [Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor (Malaysia); Ahangar, Hossein Abbastabar [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor (Malaysia); Darroudi, Majid [Advanced Materials and Nanotechnology Laboratory, Institute of Advanced Technology (ITMA), Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor (Malaysia); Zak, Ali Khorsand [Low Dimensional Material Research Center, Department of Physics, University of Malaya, Kuala Lumpur 50603 (Malaysia); Drummen, Gregor P.C., E-mail: gpcdrummen@bionano-solutions.de [Bionanoscience and Bio-Imaging Program, Cellular Stress and Ageing Program, Bio and Nano-Solutions, D-40472 Duesseldorf (Germany)

    2012-03-05

    Highlights: Black-Right-Pointing-Pointer Zinc oxide nanoparticles were synthesized via LASiS in aqueous starch solution. Black-Right-Pointing-Pointer Nanoparticles of {+-}15 nm are produced with a narrow size distribution. Black-Right-Pointing-Pointer Starch can be used as a template to control nanoparticle size. Black-Right-Pointing-Pointer Starch stabilizes zinc oxide nanoparticles in solution through steric hindrance. - Abstract: Zinc oxide is a semiconductor with exceptional thermal, luminescent and electrical properties, even compared with other semiconducting nanoparticles. Its potential for advanced applications in lasers and light emitting diodes, as bio-imaging agent, in biosensors and as drug delivery vehicles, in ointments, coatings and pigments has pulled zinc oxide into the focus of various scientific and engineering research fields. Recently we started investigating if nanoparticle synthesis via laser ablation in the presence of natural stabilizers allows control over size and shape and constitutes a useful, uncomplicated alternative over conventional synthesis methods. In the current paper, we determined the ability of natural starch to act as a size controller and stabilizer in the preparation of zinc oxide nanoparticles via ablation of a ZnO plate in a starch solution with a nanosecond Q-Switched Nd:YAG pulsed laser at its original wavelength ({lambda} = 1064 nm). Our results show that the particle diameter decreases with increasing laser irradiation time to a mean nanoparticle size of approximately 15 nm with a narrow size distribution. Furthermore, the obtained particle size in starch solution is considerably smaller compared with analogous ZnO nanoparticle synthesis in distilled water. The synthesized and capped nanoparticles retained their photoluminescent properties, but showed blue emission rather than the often reported green luminescence. Evaluation of old preparations compared with freshly made samples showed no agglomeration or

  13. Laser beam uniformity and stability using homogenizer-based fiber optic launch method: square core fiber delivery

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.

  14. Feedback-stabilized fractional fringe laser interferometer for plasma density measurements

    International Nuclear Information System (INIS)

    Schneider, J.; Robertson, S.

    1979-01-01

    A feedback stabilization technique is described for a fractional fringe interferometer measuring plasma electron densities. Using this technique, a CO 2 laser Michelson interferometer with a pyroelectric detector exhibited a sensitivity of 3.4 x 10 -4 fringe on a 1-ms time scale and, due to acoustic pickup, 1.8 x 10 -2 fringe on a 10-ms time scale. The rise time is 45 μs. Stabilization against slow drifts in mirror distances is achieved by an electromechanically translated mirror driven by a servo system having a 0.2-s response time. A mechanical chopper in one of the two beam paths generates the signal which drives the servo system

  15. Laser surface modification of Yttria Stabilized Zirconia (YSZ) thermal barrier coating on AISI H13 tool steel substrate

    Science.gov (United States)

    Reza, M. S.; Aqida, S. N.; Ismail, I.

    2018-03-01

    This paper presents laser surface modification of plasma sprayed yttria stabilized zirconia (YSZ) coating to seal porosity defect. Laser surface modification on plasma sprayed YSZ was conducted using 300W JK300HPS Nd: YAG laser at different operating parameters. Parameters varied were laser power and pulse frequency with constant residence time. The coating thickness was measured using IM7000 inverted optical microscope and surface roughness was analysed using two-dimensional Mitutoyo Surface Roughness Tester. Surface roughness of laser surface modification of YSZ H-13 tool steel decreased significantly with increasing laser power and decreasing pulse frequency. The re-melted YSZ coating showed higher hardness properties compared to as-sprayed coating surface. These findings were significant to enhance thermal barrier coating surface integrity for dies in semi-solid processing.

  16. Thermal stability of pulsed laser deposited iridium oxide thin films at low oxygen atmosphere

    Science.gov (United States)

    Gong, Yansheng; Wang, Chuanbin; Shen, Qiang; Zhang, Lianmeng

    2013-11-01

    Iridium oxide (IrO2) thin films have been regarded as a leading candidate for bottom electrode and diffusion barrier of ferroelectric capacitors, some process related issues need to be considered before integrating ferroelectric capacitors into memory cells. This paper presents the thermal stability of pulsed laser deposited IrO2 thin films at low oxygen atmosphere. Emphasis was given on the effect of post-deposition annealing temperature at different oxygen pressure (PO2) on the crystal structure, surface morphology, electrical resistivity, carrier concentration and mobility of IrO2 thin films. The results showed that the thermal stability of IrO2 thin films was strongly dependent on the oxygen pressure and annealing temperature. IrO2 thin films can stably exist below 923 K at PO2 = 1 Pa, which had a higher stability than the previous reported results. The surface morphology of IrO2 thin films depended on PO2 and annealing temperature, showing a flat and uniform surface for the annealed films. Electrical properties were found to be sensitive to both the annealing temperature and oxygen pressure. The room-temperature resistivity of IrO2 thin films with a value of 49-58 μΩ cm increased with annealing temperature at PO2 = 1 Pa. The thermal stability of IrO2 thin films as a function of oxygen pressure and annealing temperature was almost consistent with thermodynamic calculation.

  17. Process stability during fiber laser-arc hybrid welding of thick steel plates

    Science.gov (United States)

    Bunaziv, Ivan; Frostevarg, Jan; Akselsen, Odd M.; Kaplan, Alexander F. H.

    2018-03-01

    Thick steel plates are frequently used in shipbuilding, pipelines and other related heavy industries, and are usually joined by arc welding. Deep penetration laser-arc hybrid welding could increase productivity but has not been thoroughly investigated, and is therefore usually limited to applications with medium thickness (5-15 mm) sections. A major concern is process stability, especially when using modern welding consumables such as metal-cored wire and advanced welding equipment. High speed imaging allows direct observation of the process so that process behavior and phenomena can be studied. In this paper, 45 mm thick high strength steel was welded (butt joint double-sided) using the fiber laser-MAG hybrid process utilizing a metal-cored wire without pre-heating. Process stability was monitored under a wide range of welding parameters. It was found that the technique can be used successfully to weld thick sections with appropriate quality when the parameters are optimized. When comparing conventional pulsed and the more advanced cold metal transfer pulse (CMT+P) arc modes, it was found that both can provide high quality welds. CMT+P arc mode can provide more stable droplet transfer over a limited range of travel speeds. At higher travel speeds, an unstable metal transfer mechanism was observed. Comparing leading arc and trailing arc arrangements, the leading arc configuration can provide higher quality welds and more stable processing at longer inter-distances between the heat sources.

  18. Time resolved studies of H{sub 2}{sup +} dissociation with phase-stabilized laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Bettina

    2010-06-23

    In the course of this thesis, experimental studies on the dissociation of H{sub 2}{sup +}(H{sub 2}{sup +}{yields}p+H) in ultrashort laser pulses with a stabilized carrier-envelope phase (CEP) were carried out. In single-pulse measurements, the ability to control the emission direction of low energetic protons, i.e. the localization of the bound electron at one of the nuclei after dissociation, by the CEP was demonstrated. The coincident detection of the emitted protons and electrons and the measurement of their three-dimensional momentum vectors with a reaction microscope allowed to clarify the localization mechanism. Further control was achieved by a pump-control scheme with two timedelayed CEP-stabilized laser pulses. Here the neutral H{sub 2} molecule was ionized in the first pulse and dissociation was induced by the second pulse. Electron localization was shown to depend on the properties of the bound nuclear wave packet in H{sub 2}{sup +} at the time the control pulse is applied, demonstrating the ability to use the shape and dynamics of the nuclear wave packet as control parameters. Wave packet simulations were performed reproducing qualitatively the experimental results of the single and the two-pulse measurements. For both control schemes, intuitive models are presented, which qualitatively explain the main features of the obtained results. (orig.)

  19. Beam shaping diffuser based fiber injection for increasing stability of industrial robotic laser applications

    Science.gov (United States)

    Lizotte, Todd E.; Dickey, Fred M.

    2013-09-01

    This paper documents the investigation of a diffuser based fiber injection system and its successful implementation and experimental testing in a robotic industrial process. This is a new concept based on the idea that a diffuser that has the angular radiation pattern matching the NA of the fiber can be used to approximate the field pattern at the face of a mode filled fiber. The research considered two approaches to this problem. The two related approaches to the problem were developed conceptually and analytically for two predominant wavelengths of interest, 1030 nm and 532 nm. The first is an implementation that would consist of illuminating the diffuser with a uniform spot having the same shape as the fiber core and imaging the illuminated spot onto the fiber face. The other approach is the use of a far-field (Fourier transform) diffractive element with a transform lens. This paper will provide an overview of the analytics and testing of the later concept (Fourier transform) and the experimental implementation of the design to a laser fiber coupling system to launch a 532 nm pulsed laser beam into a square core fiber optical beam delivery system. Further detail will be shared with the experimental performance of the design when integrated within a multi-axis robotic arm, which has six degrees of freedom. These results will include how the fiber injection system improved laser beam stability during process operations, in comparison to traditional simple lens injection methods.

  20. Yb-doped aluminophosphosilicate ternary fiber with high efficiency and excellent laser stability

    Science.gov (United States)

    Li, Yuwei; Peng, Kun; Zhan, Huan; Liu, Shuang; Ni, Li; Wang, Yuying; Yu, Juan; Wang, Xiaolong; Wang, Jianjun; Jing, Feng; Lin, Aoxiang

    2018-03-01

    By using chelate precursor doping technique and traditional modified chemical vapor deposition system, we fabricated Yb-doped aluminophosphosilicate (Al2O3-P2O5-SiO2, ternary Yb-APS) large-mode-area fiber and reported on its laser performance. The fiber preform was doped with Al, P and Yb with concentration of ∼8000 ppm, ∼1700 ppm and ∼400 ppm in molar percent, respectively. Tested with master oscillator power amplifier system, the home-made Yb-APS fiber was found to present 1.02 kW at 1061.1 nm with a high slope efficiency of 81.2% and excellent laser stability with power fluctuation less than ±1.1% for over 10 h. Compared with Yb-doped aluminosilicate (Al2O3-SiO2, binary Yb-AS) fiber, the introduction of P2O5 effectively suppressed photodarkening effect even the P/Al ratio is much less than 1, indicating that Yb-APS fiber is a better candidate for high power fiber lasers.

  1. Study of reverse Brayton cryocooler with Helium-Neon mixture for HTS cable

    Science.gov (United States)

    Dhillon, A. K.; Ghosh, P.

    2017-12-01

    As observed in the earlier studies, helium is more efficient than neon as a refrigerant in a reverse Brayton cryocooler (RBC) from the thermodynamic point of view. However, the lower molecular weight of helium leads to higher refrigerant inventory as compared to neon. Thus, helium is suitable to realize the high thermodynamic efficiency of RBC whereas neon is appropriate for the compactness of the RBC. A binary mixture of helium and neon can be used to achieve high thermodynamic efficiency in the compact reverse Brayton cycle (RBC) based cryocooler. In this paper, an attempt has been made to analyze the thermodynamic performance of the RBC with a binary mixture of helium and neon as the working fluid to provide 1 kW cooling load for high temperature superconductor (HTS) power cables working with a temperature range of 50 K to 70 K. The basic RBC is simulated using Aspen HYSYS V8.6®, a commercial process simulator. Sizing of each component based on the optimized process parameters for each refrigerant is performed based on a computer code developed using Engineering Equation Solver (EES-V9.1). The recommendation is provided for the optimum mixture composition of the refrigerant based on the trade-off factors like thermodynamic efficiency such as the exergy efficiency and equipment considerations. The outcome of this study may be useful for recommending a suitable refrigerant for the RBC operating at a temperature level of 50 K to 70 K.

  2. Self-focusing, self modulation and stability properties of laser beam propagating in plasma: A variational approach

    International Nuclear Information System (INIS)

    Kaur, Ravinder; Gill, Tarsem Singh; Mahajan, Ranju

    2010-01-01

    Laboratory as well as Particle in cell (PIC) simulation experiments reveal the strong flow of energetic electrons co-moving with laser beam in laser plasma interaction. Equation governing the evolution of complex envelope in slowly varying envelope approximation is nonlinear parabolic equation. A Lagrangian for the problem is set up and assuming a trial Gaussian profile, we solve the reduced Lagrangian problem for beam width and curvature. Besides self-focusing and self-modulation of laser beam, we observe that stability properties of such plasma system are studied about equilibrium values using this variational approach. We obtained an eigen value equation, which is cubic in nature and investigated the criterion for stability using Hurwitz conditions for laser beam plasma system.

  3. Effect of Low Power Laser Irradiation on the Ability of Cell Growth and Myogenic Differentiation of Myoblasts Cultured In Vitro

    Directory of Open Access Journals (Sweden)

    Cui-Ping Zhang

    2014-01-01

    Full Text Available As a therapeutic modality, low power laser irradiation (LPLI has been used clinically in the treatment of skeletal muscle injuries and other myopathic conditions, but the cellular and molecular mechanisms attributed to this therapy were still unclear. Myoblasts are a type of myogenic stem cells quiescence in mature skeletal muscle fibers and are considered as the source cells during the regenerating process. The purpose of this paper was to investigate the effects of LPLI on the proliferation and myogenic differentiation of the cultured myoblasts and to find out the major candidates responsible for LPLI-induced muscle regeneration in vivo. In this study, primary rat myoblasts were exposed to helium-neon (He-Ne laser. Cell proliferation, differentiation, and the cellular responses to LPLI were monitored by using morphological observation and molecular biological methods. It was found that LPLI at a certain fluence could increase the cell growth potential for myoblasts and further induce more cells entering into S phase of the mitotic cycle as indicated by high levels of bromodeoxyuridine (BrdU incorporation, while at the same time inhibiting their in vitro differentiation and decreasing the expression of myogenic regulatory genes to a certain extent. Taken together, these results provide experimental evidence for the clinical applications of LPLI in regenerating skeletal muscle.

  4. Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators.

    Science.gov (United States)

    Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi; Minoshima, Kaoru

    2013-09-01

    A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

  5. Analysis of feature stability for laser-based determination of tissue thickness

    Science.gov (United States)

    Ernst, Floris; Schweikard, Achim; Stüber, Patrick; Bruder, Ralf; Wagner, Benjamin; Wissel, Tobias

    2015-03-01

    Localisation of the cranium is necessary for accurate stereotactic radiotherapy of malign lesions in the brain. This is achieved by immobilizing the patient's head (typically by using thermoplastic masks, bite blocks or combinations thereof) and x-ray imaging to determine the actual position of the patient with respect to the treatment device. In previous work we have developed a novel method for marker-less and non-invasive tracking of the skull using a combination of laser-based surface triangulation and the analysis of backscattered feature patterns of a tightly collimated NIR laser beam scanned over the patient's forehead. An HDR camera is coupled into the beam path of the laser scanning system to acquire one image per projected laser point. We have demonstrated that this setup is capable of accurately determining the tissue thickness for each triangulation point and consequently allows detecting the surface of the cranial bone with sub-millimetre accuracy. Typical clinical settings (treatment times of 15-90 min) require feature stability over time, since the determination of tissue thickness is achieved by machine learning methods trained on initial feature scans. We have collected initial scans of the forehead as well as long-term backscatter data (20 images per seconds over 30 min) from five subjects and extracted the relevant tissue features from the image streams. Based on the knowledge of the relationship between the tissue feature values and the tissue thickness, the analysis of the long-term data showed that the noise level is low enough to allow robust discrimination of tissue thicknesses of 0.5 mm.

  6. Developing Stabilized Lasers, Measuring their Frequencies, demoting the Metre, inventing the Comb, and further consequences

    Science.gov (United States)

    Hall, John L.

    2010-02-01

    Michelson's 1907 proposal to define the SI Metre in terms of an optical wavelength was realized only in 1960, based on a ^86Krypton discharge lamp. The same year saw the cw HeNe laser arrive and a future redefinition based on laser technology assured. Separation in the late 60's of the laser's gain and spectral-reference-gas functions led to unprecedented levels of laser frequency stability and reproducibility. In addition to HeNe:CH4 system at 3392 nm and HeNe:I2 at 633 nm, systems at 514 nm and 10600 nm were studied. Absolute frequency measurement became the holy grail and some NBS team experiences will be shared. We measured both frequency and wavelength in 1972, and so obtained a speed of light value, improved 100-fold in accuracy. During the next decade, the NBS value of c was confirmed by other national labs, and frequency metrology was extended to the 473 THz (633 nm) Iodine-based wavelength standard. This frequency to ˜10 digit accuracy was obtained in 1983, thus setting the stage for redefining the SI Metre. By consensus choice the value 299 792 458 m/s was adopted for the speed of light, effectively reducing the Metre to a derived SI quantity. Knowledge of the frequency of the particular laser being utilized was controlled by International intercomparisons, but the need for a fast and accurate means to make these laser frequency measurements was obvious. Creative proposals by H"ansch and by Chebotayev were to use ultra-fast repetitive pulses to create an ``Optical Comb,'' but it was years before any technical basis existed to implement their Fourier dreams. Finally, in 1999 the last needed capability was demonstrated -- continuum production at 100 MHz rates and non-destructive power levels. By May 2000 phase-locked combs were operational in both Garching and Boulder, substantially accelerated by their collaborative interactions. Within 18 months all the known proposed ``optical frequency standards'' had been accurately measured via Comb techniques. )

  7. Soft-tissue injuries from sports activities and traffic accidents--treatment with low-level laser therapy: a multicenter double-blind placebo-controlled clinical study on 132 patients

    Science.gov (United States)

    Simunovic, Zlatko; Trobonjaca, Tatjana

    2000-06-01

    The aim of current multicenter clinical study was to assess the efficacy of low energy-level laser therapy (LLLT) in the treatment of soft tissue injuries compared to the placebo and classical phyiotherapeutic procedures. This clinical study was conducted in two centers located in Locarno, Switzerland and Opatija, Croatia. Two types of irradiation techniques were used: (1) direct, skin contact technique for treatment of trigger points where IR diode laser 830 nm continuous wave was applied; and (2) scanning technique for irradiation of larger surface area with use of Helium Neon laser 632.8 nm combined with IR diode laser 904 nm pulsed wave. Results were evaluated according to clinical parameters like: hematoma, swelling, heat, pan and loss of function. The findings were statistically analyzed via chi- square test. Results have demonstrated that the recovery process was accelerated in 85 percent of patients treated with LLLT compared to the control group of patients. The results and advantages obtained proved once again the efficacy of LLLT as a new and successful way to treat soft tissue injuries.

  8. Monolithic stabilized Yb-fiber All-PM laser directly delivering nJ-level femtosecond pulses

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Liu, Xiaomin; Lægsgaard, Jesper

    2008-01-01

    We present a monolithic, self-starting, all-PM, stabilized Yb-fiber laser, pulse-compressed in a hollow-core PM photonic crystal fiber, providing the 370 fs pulses of 4 nJ energy with high mode quality.......We present a monolithic, self-starting, all-PM, stabilized Yb-fiber laser, pulse-compressed in a hollow-core PM photonic crystal fiber, providing the 370 fs pulses of 4 nJ energy with high mode quality....

  9. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    DEFF Research Database (Denmark)

    Pryds, N.; Christensen, Bo Toftmann; Bilde-Sørensen, Jørgen

    2006-01-01

    Films of yuria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive Xray spectrome......Films of yuria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive Xray...

  10. Stabilization of the Rayleigh - Taylor instability with convection in an ablatively accelerated laser plasma

    International Nuclear Information System (INIS)

    Bud'ko, A.B.; Liberman, M.A.

    1992-01-01

    In the framework of WKB approximation the problem is studied of stabilizing the Rayleigh - Taylor instability with unhomogeneous convective flow, developing in the ablation zone during the ablative acceleration of the laser target plasma. The eigenvalue (instability growth rates) problem is reduced to solving an algebraic equation with the coefficients depending on the unperturbed profile structure of hydrodynamic variables. For the important case of the incompressible plasma subsonic flow, the instability growth rates is shown to vanish at k=k 0 =max(2(g|∇ ln p|) 1/2 /ν). The consistency condition of the model consists in the smallness of the local Froude number in the region of instability development. However, as seen from the comparison with the numerical calculations, the model is well appicable also for the case of the sufficiently abrupt density gradient provided the Froude number is of order of unity

  11. Alignment-stabilized interference filter-tuned external-cavity quantum cascade laser.

    Science.gov (United States)

    Kischkat, Jan; Semtsiv, Mykhaylo P; Elagin, Mikaela; Monastyrskyi, Grygorii; Flores, Yuri; Kurlov, Sergii; Peters, Sven; Masselink, W Ted

    2014-12-01

    A passively alignment-stabilized external cavity quantum cascade laser (EC-QCL) employing a "cat's eye"-type retroreflector and an ultra-narrowband transmissive interference filter for wavelength selection is demonstrated and experimentally investigated. Compared with conventional grating-tuned ECQCLs, the setup is nearly two orders of magnitude more stable against misalignment of the components, and spectral fluctuation is reduced by one order of magnitude, allowing for a simultaneously lightweight and fail-safe construction, suitable for applications outdoors and in space. It also allows for a substantially greater level of miniaturization and cost reduction. These advantages fit in well with the general properties of modern QCLs in the promise to deliver useful and affordable mid-infrared-light sources for a variety of spectroscopic and imaging applications.

  12. Stabilization of Rayleigh-Taylor instability due to the spontaneous magnetic field in laser produced plasma

    International Nuclear Information System (INIS)

    Ogasawara, Masatada; Takita, Masami.

    1981-08-01

    Spontaneous magnetic fields due to the temperature gradient nabla T 0 produced by a focussed laser beam on one point of a pellet are taken into account in deriving the dispersion relation of Rayleigh-Taylor instability. Growth rate γ decreases with time. Density fluctuation with wavelength shorter than 1.5(R/L sub(T)) x (n sub(s)/n 0 )sup(1/2) μm is remarkably stabilized, where R, L sub(T), n sub(s) and n 0 are the radius of a pellet, L sub(T)sup(-1) = + nabla T 0 /T 0 + , number densities of solid and the pellet. Validity condition of the theory is γt 0 >> 1 or in another form R >> L, where t 0 is the time of thermal expansion of a pellet and L -1 = + nabla n 0 /n 0 + . (author)

  13. arXiv Mechanical stability of the CMS strip tracker measured with a laser alignment system

    CERN Document Server

    Sirunyan, Albert M; Adam, Wolfgang; Aşılar, Ece; Bergauer, Thomas; Brandstetter, Johannes; Brondolin, Erica; Dragicevic, Marko; Erö, Janos; Flechl, Martin; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hartl, Christian; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; König, Axel; Krätschmer, Ilse; Liko, Dietrich; Matsushita, Takashi; Mikulec, Ivan; Rabady, Dinyar; Rad, Navid; Rahbaran, Babak; Rohringer, Herbert; Schieck, Jochen; Strauss, Josef; Waltenberger, Wolfgang; Wulz, Claudia-Elisabeth; Dvornikov, Oleg; Makarenko, Vladimir; Mossolov, Vladimir; Suarez Gonzalez, Juan; Zykunov, Vladimir; Shumeiko, Nikolai; Alderweireldt, Sara; De Wolf, Eddi A; Janssen, Xavier; Lauwers, Jasper; Van De Klundert, Merijn; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Abu Zeid, Shimaa; Blekman, Freya; D'Hondt, Jorgen; Daci, Nadir; De Bruyn, Isabelle; Deroover, Kevin; Lowette, Steven; Moortgat, Seth; Moreels, Lieselotte; Olbrechts, Annik; Python, Quentin; Skovpen, Kirill; Tavernier, Stefaan; Van Doninck, Walter; Van Mulders, Petra; Van Parijs, Isis; Brun, Hugues; Clerbaux, Barbara; De Lentdecker, Gilles; Delannoy, Hugo; Fasanella, Giuseppe; Favart, Laurent; Goldouzian, Reza; Grebenyuk, Anastasia; Karapostoli, Georgia; Lenzi, Thomas; Léonard, Alexandre; Luetic, Jelena; Maerschalk, Thierry; Marinov, Andrey; Randle-conde, Aidan; Seva, Tomislav; Vander Velde, Catherine; Vanlaer, Pascal; Vannerom, David; Yonamine, Ryo; Zenoni, Florian; Zhang, Fengwangdong; Cimmino, Anna; Cornelis, Tom; Dobur, Didar; Fagot, Alexis; Gul, Muhammad; Khvastunov, Illia; Poyraz, Deniz; Salva Diblen, Sinem; Schöfbeck, Robert; Tytgat, Michael; Van Driessche, Ward; Yazgan, Efe; Zaganidis, Nicolas; Bakhshiansohi, Hamed; Beluffi, Camille; Bondu, Olivier; Brochet, Sébastien; Bruno, Giacomo; Caudron, Adrien; De Visscher, Simon; Delaere, Christophe; Delcourt, Martin; Francois, Brieuc; Giammanco, Andrea; Jafari, Abideh; Komm, Matthias; Krintiras, Georgios; Lemaitre, Vincent; Magitteri, Alessio; Mertens, Alexandre; Musich, Marco; Piotrzkowski, Krzysztof; Quertenmont, Loic; Selvaggi, Michele; Vidal Marono, Miguel; Wertz, Sébastien; Beliy, Nikita; Aldá Júnior, Walter Luiz; Alves, Fábio Lúcio; Alves, Gilvan; Brito, Lucas; Hensel, Carsten; Moraes, Arthur; Pol, Maria Elena; Rebello Teles, Patricia; Belchior Batista Das Chagas, Ewerton; Carvalho, Wagner; Chinellato, Jose; Custódio, Analu; Melo Da Costa, Eliza; Da Silveira, Gustavo Gil; De Jesus Damiao, Dilson; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Huertas Guativa, Lina Milena; Malbouisson, Helena; Matos Figueiredo, Diego; Mora Herrera, Clemencia; Mundim, Luiz; Nogima, Helio; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Sznajder, Andre; Tonelli Manganote, Edmilson José; Torres Da Silva De Araujo, Felipe; Vilela Pereira, Antonio; Ahuja, Sudha; Bernardes, Cesar Augusto; Dogra, Sunil; Tomei, Thiago; De Moraes Gregores, Eduardo; Mercadante, Pedro G; Moon, Chang-Seong; Novaes, Sergio F; Padula, Sandra; Romero Abad, David; Ruiz Vargas, José Cupertino; Aleksandrov, Aleksandar; Hadjiiska, Roumyana; Iaydjiev, Plamen; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Vutova, Mariana; Dimitrov, Anton; Glushkov, Ivan; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Fang, Wenxing; Ahmad, Muhammad; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Chen, Mingshui; Chen, Ye; Cheng, Tongguang; Jiang, Chun-Hua; Leggat, Duncan; Liu, Zhenan; Romeo, Francesco; Ruan, Manqi; Shaheen, Sarmad Masood; Spiezia, Aniello; Tao, Junquan; Wang, Chunjie; Wang, Zheng; Zhang, Huaqiao; Zhao, Jingzhou; Ban, Yong; Chen, Geng; Li, Qiang; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Wang, Dayong; Xu, Zijun; Avila, Carlos; Cabrera, Andrés; Chaparro Sierra, Luisa Fernanda; Florez, Carlos; Gomez, Juan Pablo; González Hernández, Carlos Felipe; Ruiz Alvarez, José David; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Puljak, Ivica; Ribeiro Cipriano, Pedro M; Sculac, Toni; Antunovic, Zeljko; Kovac, Marko; Brigljevic, Vuko; Ferencek, Dinko; Kadija, Kreso; Mesic, Benjamin; Susa, Tatjana; Attikis, Alexandros; Mavromanolakis, Georgios; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Rykaczewski, Hans; Tsiakkouri, Demetra; Finger, Miroslav; Finger Jr, Michael; Carrera Jarrin, Edgar; Ellithi Kamel, Ali; Mahmoud, Mohammed; Radi, Amr; Kadastik, Mario; Perrini, Lucia; Raidal, Martti; Tiko, Andres; Veelken, Christian; Eerola, Paula; Pekkanen, Juska; Voutilainen, Mikko; Härkönen, Jaakko; Jarvinen, Terhi; Karimäki, Veikko; Kinnunen, Ritva; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Tuominiemi, Jorma; Tuovinen, Esa; Wendland, Lauri; Talvitie, Joonas; Tuuva, Tuure; Besancon, Marc; Couderc, Fabrice; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Favaro, Carlotta; Ferri, Federico; Ganjour, Serguei; Ghosh, Saranya; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Kucher, Inna; Locci, Elizabeth; Machet, Martina; Malcles, Julie; Rander, John; Rosowsky, André; Titov, Maksym; Abdulsalam, Abdulla; Antropov, Iurii; Baffioni, Stephanie; Beaudette, Florian; Busson, Philippe; Cadamuro, Luca; Chapon, Emilien; Charlot, Claude; Davignon, Olivier; Granier de Cassagnac, Raphael; Jo, Mihee; Lisniak, Stanislav; Miné, Philippe; Nguyen, Matthew; Ochando, Christophe; Ortona, Giacomo; Paganini, Pascal; Pigard, Philipp; Regnard, Simon; Salerno, Roberto; Sirois, Yves; Strebler, Thomas; Yilmaz, Yetkin; Zabi, Alexandre; Zghiche, Amina; Agram, Jean-Laurent; Andrea, Jeremy; Aubin, Alexandre; Bloch, Daniel; Brom, Jean-Marie; Buttignol, Michael; Chabert, Eric Christian; Chanon, Nicolas; Collard, Caroline; Conte, Eric; Coubez, Xavier; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Le Bihan, Anne-Catherine; Van Hove, Pierre; Gadrat, Sébastien; Beauceron, Stephanie; Bernet, Colin; Boudoul, Gaelle; Carrillo Montoya, Camilo Andres; Chierici, Roberto; Contardo, Didier; Courbon, Benoit; Depasse, Pierre; El Mamouni, Houmani; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Grenier, Gérald; Ille, Bernard; Lagarde, Francois; Laktineh, Imad Baptiste; Lethuillier, Morgan; Mirabito, Laurent; Pequegnot, Anne-Laure; Perries, Stephane; Popov, Andrey; Sabes, David; Sordini, Viola; Vander Donckt, Muriel; Verdier, Patrice; Viret, Sébastien; Toriashvili, Tengizi; Lomidze, David; Autermann, Christian; Beranek, Sarah; Feld, Lutz; Kiesel, Maximilian Knut; Klein, Katja; Lipinski, Martin; Preuten, Marius; Schomakers, Christian; Schulz, Johannes; Verlage, Tobias; Albert, Andreas; Brodski, Michael; Dietz-Laursonn, Erik; Duchardt, Deborah; Endres, Matthias; Erdmann, Martin; Erdweg, Sören; Esch, Thomas; Fischer, Robert; Güth, Andreas; Hamer, Matthias; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Knutzen, Simon; Merschmeyer, Markus; Meyer, Arnd; Millet, Philipp; Mukherjee, Swagata; Olschewski, Mark; Padeken, Klaas; Pook, Tobias; Radziej, Markus; Reithler, Hans; Rieger, Marcel; Scheuch, Florian; Sonnenschein, Lars; Teyssier, Daniel; Thüer, Sebastian; Cherepanov, Vladimir; Flügge, Günter; Kargoll, Bastian; Kress, Thomas; Künsken, Andreas; Lingemann, Joschka; Müller, Thomas; Nehrkorn, Alexander; Nowack, Andreas; Pistone, Claudia; Pooth, Oliver; Stahl, Achim; Aldaya Martin, Maria; Arndt, Till; Asawatangtrakuldee, Chayanit; Beernaert, Kelly; Behnke, Olaf; Behrens, Ulf; Bin Anuar, Afiq Aizuddin; Borras, Kerstin; Campbell, Alan; Connor, Patrick; Contreras-Campana, Christian; Costanza, Francesco; Diez Pardos, Carmen; Dolinska, Ganna; Eckerlin, Guenter; Eckstein, Doris; Eichhorn, Thomas; Eren, Engin; Gallo, Elisabetta; Garay Garcia, Jasone; Geiser, Achim; Gizhko, Andrii; Grados Luyando, Juan Manuel; Grohsjean, Alexander; Gunnellini, Paolo; Harb, Ali; Hauk, Johannes; Hempel, Maria; Jung, Hannes; Kalogeropoulos, Alexis; Karacheban, Olena; Kasemann, Matthias; Keaveney, James; Kleinwort, Claus; Korol, Ievgen; Krücker, Dirk; Lange, Wolfgang; Lelek, Aleksandra; Lenz, Teresa; Leonard, Jessica; Lipka, Katerina; Lobanov, Artur; Lohmann, Wolfgang; Mankel, Rainer; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mittag, Gregor; Mnich, Joachim; Mussgiller, Andreas; Pitzl, Daniel; Placakyte, Ringaile; Raspereza, Alexei; Roland, Benoit; Sahin, Mehmet Özgür; Saxena, Pooja; Schoerner-Sadenius, Thomas; Spannagel, Simon; Stefaniuk, Nazar; Van Onsem, Gerrit Patrick; Walsh, Roberval; Wissing, Christoph; Blobel, Volker; Centis Vignali, Matteo; Draeger, Arne-Rasmus; Dreyer, Torben; Garutti, Erika; Gonzalez, Daniel; Haller, Johannes; Hoffmann, Malte; Junkes, Alexandra; Klanner, Robert; Kogler, Roman; Kovalchuk, Nataliia; Lapsien, Tobias; Marchesini, Ivan; Marconi, Daniele; Meyer, Mareike; Niedziela, Marek; Nowatschin, Dominik; Pantaleo, Felice; Peiffer, Thomas; Perieanu, Adrian; Poehlsen, Jennifer; Scharf, Christian; Schleper, Peter; Schmidt, Alexander; Schumann, Svenja; Schwandt, Joern; Stadie, Hartmut; Steinbrück, Georg; Stober, Fred-Markus Helmut; Stöver, Marc; Tholen, Heiner; Troendle, Daniel; Usai, Emanuele; Vanelderen, Lukas; Vanhoefer, Annika; Vormwald, Benedikt; Akbiyik, Melike; Barth, Christian; Baur, Sebastian; Baus, Colin; Berger, Joram; Butz, Erik; Caspart, René; Chwalek, Thorsten; Colombo, Fabio; De Boer, Wim; Dierlamm, Alexander; Fink, Simon; Freund, Benedikt; Friese, Raphael; Giffels, Manuel; Gilbert, Andrew; Goldenzweig, Pablo; Haitz, Dominik; Hartmann, Frank; Heindl, Stefan Michael; Husemann, Ulrich; Katkov, Igor; Kudella, Simon; Mildner, Hannes; Mozer, Matthias Ulrich; Müller, Thomas; Plagge, Michael; Quast, Gunter; Rabbertz, Klaus; Röcker, Steffen; Roscher, Frank; Schröder, Matthias; Shvetsov, Ivan; Sieber, Georg; Simonis, Hans-Jürgen; Ulrich, Ralf; Wayand, Stefan; Weber, Marc; Weiler, Thomas; Williamson, Shawn; Wöhrmann, Clemens; Wolf, Roger; Anagnostou, Georgios; Daskalakis, Georgios; Geralis, Theodoros; Giakoumopoulou, Viktoria Athina; Kyriakis, Aristotelis; Loukas, Demetrios; Topsis-Giotis, Iasonas; Kesisoglou, Stilianos; Panagiotou, Apostolos; Saoulidou, Niki; Tziaferi, Eirini; Evangelou, Ioannis; Flouris, Giannis; Foudas, Costas; Kokkas, Panagiotis; Loukas, Nikitas; Manthos, Nikolaos; Papadopoulos, Ioannis; Paradas, Evangelos; Filipovic, Nicolas; Pasztor, Gabriella; Bencze, Gyorgy; Hajdu, Csaba; Horvath, Dezso; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Zsigmond, Anna Julia; Beni, Noemi; Czellar, Sandor; Karancsi, János; Makovec, Alajos; Molnar, Jozsef; Szillasi, Zoltan; Bartók, Márton; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Komaragiri, Jyothsna Rani; Bahinipati, Seema; Bhowmik, Sandeep; Choudhury, Somnath; Mal, Prolay; Mandal, Koushik; Nayak, Aruna; Sahoo, Deepak Kumar; Sahoo, Niladribihari; Swain, Sanjay Kumar; Bansal, Sunil; Beri, Suman Bala; Bhatnagar, Vipin; Chawla, Ridhi; Bhawandeep, Bhawandeep; Kalsi, Amandeep Kaur; Kaur, Anterpreet; Kaur, Manjit; Kumar, Ramandeep; Kumari, Priyanka; Mehta, Ankita; Mittal, Monika; Singh, Jasbir; Walia, Genius; Kumar, Ashok; Bhardwaj, Ashutosh; Choudhary, Brajesh C; Garg, Rocky Bala; Keshri, Sumit; Malhotra, Shivali; Naimuddin, Md; Ranjan, Kirti; Sharma, Ramkrishna; Sharma, Varun; Bhattacharya, Rajarshi; Bhattacharya, Satyaki; Chatterjee, Kalyanmoy; Dey, Sourav; Dutt, Suneel; Dutta, Suchandra; Ghosh, Shamik; Majumdar, Nayana; Modak, Atanu; Mondal, Kuntal; Mukhopadhyay, Supratik; Nandan, Saswati; Purohit, Arnab; Roy, Ashim; Roy, Debarati; Roy Chowdhury, Suvankar; Sarkar, Subir; Sharan, Manoj; Thakur, Shalini; Behera, Prafulla Kumar; Chudasama, Ruchi; Dutta, Dipanwita; Jha, Vishwajeet; Kumar, Vineet; Mohanty, Ajit Kumar; Netrakanti, Pawan Kumar; Pant, Lalit Mohan; Shukla, Prashant; Topkar, Anita; Aziz, Tariq; Dugad, Shashikant; Kole, Gouranga; Mahakud, Bibhuprasad; Mitra, Soureek; Mohanty, Gagan Bihari; Parida, Bibhuti; Sur, Nairit; Sutar, Bajrang; Banerjee, Sudeshna; Dewanjee, Ram Krishna; Ganguly, Sanmay; Guchait, Monoranjan; Jain, Sandhya; Kumar, Sanjeev; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Sarkar, Tanmay; Wickramage, Nadeesha; Chauhan, Shubhanshu; Dube, Sourabh; Hegde, Vinay; Kapoor, Anshul; Kothekar, Kunal; Pandey, Shubham; Rane, Aditee; Sharma, Seema; Chenarani, Shirin; Eskandari Tadavani, Esmaeel; Etesami, Seyed Mohsen; Khakzad, Mohsen; Mohammadi Najafabadi, Mojtaba; Naseri, Mohsen; Paktinat Mehdiabadi, Saeid; Rezaei Hosseinabadi, Ferdos; Safarzadeh, Batool; Zeinali, Maryam; Felcini, Marta; Grunewald, Martin; Abbrescia, Marcello; Calabria, Cesare; Caputo, Claudio; Colaleo, Anna; Creanza, Donato; Cristella, Leonardo; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Maggi, Giorgio; Maggi, Marcello; Miniello, Giorgia; My, Salvatore; Nuzzo, Salvatore; Pompili, Alexis; Pugliese, Gabriella; Radogna, Raffaella; Ranieri, Antonio; Selvaggi, Giovanna; Sharma, Archana; Silvestris, Lucia; Venditti, Rosamaria; Verwilligen, Piet; Abbiendi, Giovanni; Battilana, Carlo; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Campanini, Renato; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Chhibra, Simranjit Singh; Codispoti, Giuseppe; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Guiducci, Luigi; Marcellini, Stefano; Masetti, Gianni; Montanari, Alessandro; Navarria, Francesco; Perrotta, Andrea; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gian Piero; Tosi, Nicolò; Albergo, Sebastiano; Costa, Salvatore; Di Mattia, Alessandro; Giordano, Ferdinando; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Russo, Lorenzo; Sguazzoni, Giacomo; Strom, Derek; Viliani, Lorenzo; Benussi, Luigi; Bianco, Stefano; Fabbri, Franco; Piccolo, Davide; Primavera, Federica; Calvelli, Valerio; Ferro, Fabrizio; Monge, Maria Roberta; Robutti, Enrico; Tosi, Silvano; Brianza, Luca; Brivio, Francesco; Ciriolo, Vincenzo; Dinardo, Mauro Emanuele; Fiorendi, Sara; Gennai, Simone; Ghezzi, Alessio; Govoni, Pietro; Malberti, Martina; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Pigazzini, Simone; Ragazzi, Stefano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Cavallo, Nicola; De Nardo, Guglielmo; Di Guida, Salvatore; Esposito, Marco; Fabozzi, Francesco; Fienga, Francesco; Iorio, Alberto Orso Maria; Lanza, Giuseppe; Lista, Luca; Meola, Sabino; Paolucci, Pierluigi; Sciacca, Crisostomo; Thyssen, Filip; Azzi, Patrizia; Bacchetta, Nicola; Benato, Lisa; Bisello, Dario; Boletti, Alessio; Carlin, Roberto; Checchia, Paolo; Dall'Osso, Martino; De Castro Manzano, Pablo; Dorigo, Tommaso; Dosselli, Umberto; Gasparini, Fabrizio; Lacaprara, Stefano; Margoni, Martino; Maron, Gaetano; Meneguzzo, Anna Teresa; Michelotto, Michele; Montecassiano, Fabio; Pazzini, Jacopo; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Zanetti, Marco; Zotto, Pierluigi; Zumerle, Gianni; Braghieri, Alessandro; Fallavollita, Francesco; Magnani, Alice; Montagna, Paolo; Ratti, Sergio P; Re, Valerio; Riccardi, Cristina; Salvini, Paola; Vai, Ilaria; Vitulo, Paolo; Alunni Solestizi, Luisa; Bilei, Gian Mario; Ciangottini, Diego; Fanò, Livio; Lariccia, Paolo; Leonardi, Roberto; Mantovani, Giancarlo; Menichelli, Mauro; Saha, Anirban; Santocchia, Attilio; Androsov, Konstantin; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Castaldi, Rino; Ciocci, Maria Agnese; Dell'Orso, Roberto; Donato, Silvio; Fedi, Giacomo; Giassi, Alessandro; Grippo, Maria Teresa; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Rizzi, Andrea; Savoy-Navarro, Aurore; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Cipriani, Marco; Del Re, Daniele; Diemoz, Marcella; Gelli, Simone; Longo, Egidio; Margaroli, Fabrizio; Marzocchi, Badder; Meridiani, Paolo; Organtini, Giovanni; Paramatti, Riccardo; Preiato, Federico; Rahatlou, Shahram; Rovelli, Chiara; Santanastasio, Francesco; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Bartosik, Nazar; Bellan, Riccardo; Biino, Cristina; Cartiglia, Nicolo; Cenna, Francesca; Costa, Marco; Covarelli, Roberto; Degano, Alessandro; Demaria, Natale; Finco, Linda; Kiani, Bilal; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Monteil, Ennio; Monteno, Marco; Obertino, Maria Margherita; Pacher, Luca; Pastrone, Nadia; Pelliccioni, Mario; Pinna Angioni, Gian Luca; Ravera, Fabio; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Shchelina, Ksenia; Sola, Valentina; Solano, Ada; Staiano, Amedeo; Traczyk, Piotr; Belforte, Stefano; Casarsa, Massimo; Cossutti, Fabio; Della Ricca, Giuseppe; Zanetti, Anna; Kim, Dong Hee; Kim, Gui Nyun; Kim, Min Suk; Lee, Sangeun; Lee, Seh Wook; Oh, Young Do; Sekmen, Sezen; Son, Dong-Chul; Yang, Yu Chul; Lee, Ari; Kim, Hyunchul; Brochero Cifuentes, Javier Andres; Kim, Tae Jeong; Cho, Sungwoong; Choi, Suyong; Go, Yeonju; Gyun, Dooyeon; Ha, Seungkyu; Hong, Byung-Sik; Jo, Youngkwon; Kim, Yongsun; Lee, Kisoo; Lee, Kyong Sei; Lee, Songkyo; Lim, Jaehoon; Park, Sung Keun; Roh, Youn; Almond, John; Kim, Junho; Lee, Haneol; Oh, Sung Bin; Radburn-Smith, Benjamin Charles; Seo, Seon-hee; Yang, Unki; Yoo, Hwi Dong; Yu, Geum Bong; Choi, Minkyoo; Kim, Hyunyong; Kim, Ji Hyun; Lee, Jason Sang Hun; Park, Inkyu; Ryu, Geonmo; Ryu, Min Sang; Choi, Young-Il; Goh, Junghwan; Hwang, Chanwook; Lee, Jongseok; Yu, Intae; Dudenas, Vytautas; Juodagalvis, Andrius; Vaitkus, Juozas; Ahmed, Ijaz; Ibrahim, Zainol Abidin; Md Ali, Mohd Adli Bin; Mohamad Idris, Faridah; Wan Abdullah, Wan Ahmad Tajuddin; Yusli, Mohd Nizam; Zolkapli, Zukhaimira; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-De La Cruz, Ivan; Hernandez-Almada, Alberto; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Mejia Guisao, Jhovanny; Sánchez Hernández, Alberto; Carrillo Moreno, Salvador; Oropeza Barrera, Cristina; Vazquez Valencia, Fabiola; Carpinteyro, Severiano; Pedraza, Isabel; Salazar Ibarguen, Humberto Antonio; Uribe Estrada, Cecilia; Morelos Pineda, Antonio; Krofcheck, David; Butler, Philip H; Ahmad, Ashfaq; Ahmad, Muhammad; Hassan, Qamar; Hoorani, Hafeez R; Khan, Wajid Ali; Saddique, Asif; Shah, Mehar Ali; Shoaib, Muhammad; Waqas, Muhammad; Bialkowska, Helena; Bluj, Michal; Boimska, Bożena; Frueboes, Tomasz; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Zalewski, Piotr; Bunkowski, Karol; Byszuk, Adrian; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Misiura, Maciej; Olszewski, Michal; Walczak, Marek; Bargassa, Pedrame; Beirão Da Cruz E Silva, Cristóvão; Calpas, Betty; Di Francesco, Agostino; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Hollar, Jonathan; Leonardo, Nuno; Lloret Iglesias, Lara; Nemallapudi, Mythra Varun; Rodrigues Antunes, Joao; Seixas, Joao; Toldaiev, Oleksii; Vadruccio, Daniele; Varela, Joao; Vischia, Pietro; Afanasiev, Serguei; Bunin, Pavel; Gavrilenko, Mikhail; Golutvin, Igor; Gorbunov, Ilya; Kamenev, Alexey; Karjavin, Vladimir; Lanev, Alexander; Malakhov, Alexander; Matveev, Viktor; Palichik, Vladimir; Perelygin, Victor; Shmatov, Sergey; Shulha, Siarhei; Skatchkov, Nikolai; Smirnov, Vitaly; Voytishin, Nikolay; Zarubin, Anatoli; Chtchipounov, Leonid; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Kuznetsova, Ekaterina; Murzin, Victor; Oreshkin, Vadim; Sulimov, Valentin; Vorobyev, Alexey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Karneyeu, Anton; Kirsanov, Mikhail; Krasnikov, Nikolai; Pashenkov, Anatoli; Tlisov, Danila; Toropin, Alexander; Epshteyn, Vladimir; Gavrilov, Vladimir; Lychkovskaya, Natalia; Popov, Vladimir; Pozdnyakov, Ivan; Safronov, Grigory; Spiridonov, Alexander; Toms, Maria; Vlasov, Evgueni; Zhokin, Alexander; Bylinkin, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Terkulov, Adel; Baskakov, Alexey; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Kaminskiy, Alexandre; Klyukhin, Vyacheslav; Kodolova, Olga; Lokhtin, Igor; Miagkov, Igor; Obraztsov, Stepan; Petrushanko, Sergey; Savrin, Viktor; Blinov, Vladimir; Skovpen, Yuri; Shtol, Dmitry; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Elumakhov, Dmitry; Kachanov, Vassili; Kalinin, Alexey; Konstantinov, Dmitri; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Cirkovic, Predrag; Devetak, Damir; Dordevic, Milos; Milosevic, Jovan; Rekovic, Vladimir; Alcaraz Maestre, Juan; Barrio Luna, Mar; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Escalante Del Valle, Alberto; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Navarro De Martino, Eduardo; Pérez-Calero Yzquierdo, Antonio María; Puerta Pelayo, Jesus; Quintario Olmeda, Adrián; Redondo, Ignacio; Romero, Luciano; Senghi Soares, Mara; de Trocóniz, Jorge F; Missiroli, Marino; Moran, Dermot; Cuevas, Javier; Fernandez Menendez, Javier; Gonzalez Caballero, Isidro; González Fernández, Juan Rodrigo; Palencia Cortezon, Enrique; Sanchez Cruz, Sergio; Suárez Andrés, Ignacio; Vizan Garcia, Jesus Manuel; Cabrillo, Iban Jose; Calderon, Alicia; Curras, Esteban; Fernandez, Marcos; Garcia-Ferrero, Juan; Gomez, Gervasio; Lopez Virto, Amparo; Marco, Jesus; Martinez Rivero, Celso; Matorras, Francisco; Piedra Gomez, Jonatan; Rodrigo, Teresa; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Trevisani, Nicolò; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bloch, Philippe; Bocci, Andrea; Botta, Cristina; Camporesi, Tiziano; Castello, Roberto; Cepeda, Maria; Cerminara, Gianluca; Chen, Yi; D'Enterria, David; Dabrowski, Anne; Daponte, Vincenzo; David Tinoco Mendes, Andre; De Gruttola, Michele; De Roeck, Albert; Di Marco, Emanuele; Dobson, Marc; Dorney, Brian; Du Pree, Tristan; Duggan, Daniel; Dünser, Marc; Dupont, Niels; Elliott-Peisert, Anna; Everaerts, Pieter; Fartoukh, Stephane; Franzoni, Giovanni; Fulcher, Jonathan; Funk, Wolfgang; Gigi, Dominique; Gill, Karl; Girone, Maria; Glege, Frank; Gulhan, Doga; Gundacker, Stefan; Guthoff, Moritz; Harris, Philip; Hegeman, Jeroen; Innocente, Vincenzo; Janot, Patrick; Kieseler, Jan; Kirschenmann, Henning; Knünz, Valentin; Kornmayer, Andreas; Kortelainen, Matti J; Kousouris, Konstantinos; Krammer, Manfred; Lange, Clemens; Lecoq, Paul; Lourenco, Carlos; Lucchini, Marco Toliman; Malgeri, Luca; Mannelli, Marcello; Martelli, Arabella; Meijers, Frans; Merlin, Jeremie Alexandre; Mersi, Stefano; Meschi, Emilio; Milenovic, Predrag; Moortgat, Filip; Morovic, Srecko; Mulders, Martijn; Neugebauer, Hannes; Orfanelli, Styliani; Orsini, Luciano; Pape, Luc; Perez, Emmanuel; Peruzzi, Marco; Petrilli, Achille; Petrucciani, Giovanni; Pfeiffer, Andreas; Pierini, Maurizio; Racz, Attila; Reis, Thomas; Rolandi, Gigi; Rovere, Marco; Sakulin, Hannes; Sauvan, Jean-Baptiste; Schäfer, Christoph; Schwick, Christoph; Seidel, Markus; Sharma, Archana; Silva, Pedro; Sphicas, Paraskevas; Steggemann, Jan; Stoye, Markus; Takahashi, Yuta; Tosi, Mia; Treille, Daniel; Triossi, Andrea; Tsirou, Andromachi; Veckalns, Viesturs; Veres, Gabor Istvan; Verweij, Marta; Wardle, Nicholas; Wöhri, Hermine Katharina; Zagoździńska, Agnieszka; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; Kotlinski, Danek; Langenegger, Urs; Rohe, Tilman; Bachmair, Felix; Bäni, Lukas; Bianchini, Lorenzo; Casal, Bruno; Dissertori, Günther; Dittmar, Michael; Donegà, Mauro; Grab, Christoph; Heidegger, Constantin; Hits, Dmitry; Hoss, Jan; Kasieczka, Gregor; Lustermann, Werner; Mangano, Boris; Marionneau, Matthieu; Martinez Ruiz del Arbol, Pablo; Masciovecchio, Mario; Meinhard, Maren Tabea; Meister, Daniel; Micheli, Francesco; Musella, Pasquale; Nessi-Tedaldi, Francesca; Pandolfi, Francesco; Pata, Joosep; Pauss, Felicitas; Perrin, Gaël; Perrozzi, Luca; Quittnat, Milena; Rossini, Marco; Schönenberger, Myriam; Starodumov, Andrei; Tavolaro, Vittorio Raoul; Theofilatos, Konstantinos; Wallny, Rainer; Aarrestad, Thea Klaeboe; Amsler, Claude; Caminada, Lea; Canelli, Maria Florencia; De Cosa, Annapaola; Galloni, Camilla; Hinzmann, Andreas; Hreus, Tomas; Kilminster, Benjamin; Ngadiuba, Jennifer; Pinna, Deborah; Rauco, Giorgia; Robmann, Peter; Salerno, Daniel; Seitz, Claudia; Yang, Yong; Zucchetta, Alberto; Candelise, Vieri; Doan, Thi Hien; Jain, Shilpi; Khurana, Raman; Konyushikhin, Maxim; Kuo, Chia-Ming; Lin, Willis; Pozdnyakov, Andrey; Yu, Shin-Shan; Kumar, Arun; Chang, Paoti; Chang, You-Hao; Chao, Yuan; Chen, Kai-Feng; Chen, Po-Hsun; Fiori, Francesco; Hou, George Wei-Shu; Hsiung, Yee; Liu, Yueh-Feng; Lu, Rong-Shyang; Miñano Moya, Mercedes; Paganis, Efstathios; Psallidas, Andreas; Tsai, Jui-fa; Asavapibhop, Burin; Singh, Gurpreet; Srimanobhas, Norraphat; Suwonjandee, Narumon; Adiguzel, Aytul; Cerci, Salim; Damarseckin, Serdal; Demiroglu, Zuhal Seyma; Dozen, Candan; Dumanoglu, Isa; Girgis, Semiray; Gokbulut, Gul; Guler, Yalcin; Hos, Ilknur; Kangal, Evrim Ersin; Kara, Ozgun; Kayis Topaksu, Aysel; Kiminsu, Ugur; Oglakci, Mehmet; Onengut, Gulsen; Ozdemir, Kadri; Sunar Cerci, Deniz; Tali, Bayram; Turkcapar, Semra; Zorbakir, Ibrahim Soner; Zorbilmez, Caglar; Bilin, Bugra; Bilmis, Selcuk; Isildak, Bora; Karapinar, Guler; Yalvac, Metin; Zeyrek, Mehmet; Gülmez, Erhan; Kaya, Mithat; Kaya, Ozlem; Yetkin, Elif Asli; Yetkin, Taylan; Cakir, Altan; Cankocak, Kerem; Sen, Sercan; Grynyov, Boris; Levchuk, Leonid; Sorokin, Pavel; Aggleton, Robin; Ball, Fionn; Beck, Lana; Brooke, James John; Burns, Douglas; Clement, Emyr; Cussans, David; Flacher, Henning; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Jacob, Jeson; Kreczko, Lukasz; Lucas, Chris; Newbold, Dave M; Paramesvaran, Sudarshan; Poll, Anthony; Sakuma, Tai; Seif El Nasr-storey, Sarah; Smith, Dominic; Smith, Vincent J; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Calligaris, Luigi; Cieri, Davide; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Olaiya, Emmanuel; Petyt, David; Shepherd-Themistocleous, Claire; Thea, Alessandro; Tomalin, Ian R; Williams, Thomas; Baber, Mark; Bainbridge, Robert; Buchmuller, Oliver; Bundock, Aaron; Burton, Darren; Casasso, Stefano; Citron, Matthew; Colling, David; Corpe, Louie; Dauncey, Paul; Davies, Gavin; De Wit, Adinda; Della Negra, Michel; Di Maria, Riccardo; Dunne, Patrick; Elwood, Adam; Futyan, David; Haddad, Yacine; Hall, Geoffrey; Iles, Gregory; James, Thomas; Lane, Rebecca; Laner, Christian; Lucas, Robyn; Lyons, Louis; Magnan, Anne-Marie; Malik, Sarah; Mastrolorenzo, Luca; Nash, Jordan; Nikitenko, Alexander; Pela, Joao; Penning, Bjoern; Pesaresi, Mark; Raymond, David Mark; Richards, Alexander; Rose, Andrew; Scott, Edward; Seez, Christopher; Summers, Sioni; Tapper, Alexander; Uchida, Kirika; Vazquez Acosta, Monica; Virdee, Tejinder; Wright, Jack; Zenz, Seth Conrad; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Borzou, Ahmad; Call, Kenneth; Dittmann, Jay; Hatakeyama, Kenichi; Liu, Hongxuan; Pastika, Nathaniel; Bartek, Rachel; Dominguez, Aaron; Buccilli, Andrew; Cooper, Seth; Henderson, Conor; Rumerio, Paolo; West, Christopher; Arcaro, Daniel; Avetisyan, Aram; Bose, Tulika; Gastler, Daniel; Rankin, Dylan; Richardson, Clint; Rohlf, James; Sulak, Lawrence; Zou, David; Benelli, Gabriele; Cutts, David; Garabedian, Alex; Hakala, John; Heintz, Ulrich; Hogan, Julie Managan; Jesus, Orduna; Kwok, Ka Hei Martin; Laird, Edward; Landsberg, Greg; Mao, Zaixing; Narain, Meenakshi; Piperov, Stefan; Sagir, Sinan; Spencer, Eric; Syarif, Rizki; Breedon, Richard; Burns, Dustin; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Erbacher, Robin; Flores, Chad; Funk, Garrett; Gardner, Michael; Ko, Winston; Lander, Richard; Mclean, Christine; Mulhearn, Michael; Pellett, Dave; Pilot, Justin; Shalhout, Shalhout; Shi, Mengyao; Smith, John; Squires, Michael; Stolp, Dustin; Tos, Kyle; Tripathi, Mani; Bachtis, Michail; Bravo, Cameron; Cousins, Robert; Dasgupta, Abhigyan; Florent, Alice; Hauser, Jay; Ignatenko, Mikhail; Mccoll, Nickolas; Saltzberg, David; Schnaible, Christian; Valuev, Vyacheslav; Weber, Matthias; Bouvier, Elvire; Burt, Kira; Clare, Robert; Ellison, John Anthony; Gary, J William; Ghiasi Shirazi, Seyyed Mohammad Amin; Hanson, Gail; Heilman, Jesse; Jandir, Pawandeep; Kennedy, Elizabeth; Lacroix, Florent; Long, Owen Rosser; Olmedo Negrete, Manuel; Paneva, Mirena Ivova; Shrinivas, Amithabh; Si, Weinan; Wei, Hua; Wimpenny, Stephen; Yates, Brent; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; Derdzinski, Mark; Gerosa, Raffaele; Holzner, André; Klein, Daniel; Krutelyov, Vyacheslav; Letts, James; Macneill, Ian; Olivito, Dominick; Padhi, Sanjay; Pieri, Marco; Sani, Matteo; Sharma, Vivek; Simon, Sean; Tadel, Matevz; Vartak, Adish; Wasserbaech, Steven; Welke, Charles; Wood, John; Würthwein, Frank; Yagil, Avraham; Zevi Della Porta, Giovanni; Amin, Nick; Bhandari, Rohan; Bradmiller-Feld, John; Campagnari, Claudio; Dishaw, Adam; Dutta, Valentina; Franco Sevilla, Manuel; George, Christopher; Golf, Frank; Gouskos, Loukas; Gran, Jason; Heller, Ryan; Incandela, Joe; Mullin, Sam Daniel; Ovcharova, Ana; Qu, Huilin; Richman, Jeffrey; Stuart, David; Suarez, Indara; Yoo, Jaehyeok; Anderson, Dustin; Bendavid, Joshua; Bornheim, Adolf; Bunn, Julian; Duarte, Javier; Lawhorn, Jay Mathew; Mott, Alexander; Newman, Harvey B; Pena, Cristian; Spiropulu, Maria; Vlimant, Jean-Roch; Xie, Si; Zhu, Ren-Yuan; Andrews, Michael Benjamin; Ferguson, Thomas; Paulini, Manfred; Russ, James; Sun, Menglei; Vogel, Helmut; Vorobiev, Igor; Weinberg, Marc; Cumalat, John Perry; Ford, William T; Jensen, Frank; Johnson, Andrew; Krohn, Michael; Leontsinis, Stefanos; Mulholland, Troy; Stenson, Kevin; Wagner, Stephen Robert; Alexander, James; Chaves, Jorge; Chu, Jennifer; Dittmer, Susan; Mcdermott, Kevin; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Rinkevicius, Aurelijus; Ryd, Anders; Skinnari, Louise; Soffi, Livia; Tan, Shao Min; Tao, Zhengcheng; Thom, Julia; Tucker, Jordan; Wittich, Peter; Zientek, Margaret; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Apollinari, Giorgio; Apresyan, Artur; Banerjee, Sunanda; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bolla, Gino; Burkett, Kevin; Butler, Joel Nathan; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Cremonesi, Matteo; Elvira, Victor Daniel; Fisk, Ian; Freeman, Jim; Gottschalk, Erik; Gray, Lindsey; Green, Dan; Grünendahl, Stefan; Gutsche, Oliver; Hare, Daryl; Harris, Robert M; Hasegawa, Satoshi; Hirschauer, James; Hu, Zhen; Jayatilaka, Bodhitha; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Klima, Boaz; Kreis, Benjamin; Lammel, Stephan; Linacre, Jacob; Lincoln, Don; Lipton, Ron; Liu, Miaoyuan; Liu, Tiehui; Lopes De Sá, Rafael; Lykken, Joseph; Maeshima, Kaori; Magini, Nicolo; Marraffino, John Michael; Maruyama, Sho; Mason, David; McBride, Patricia; Merkel, Petra; Mrenna, Stephen; Nahn, Steve; O'Dell, Vivian; Pedro, Kevin; Prokofyev, Oleg; Rakness, Gregory; Ristori, Luciano; Sexton-Kennedy, Elizabeth; Soha, Aron; Spalding, William J; Spiegel, Leonard; Stoynev, Stoyan; Strait, James; Strobbe, Nadja; Taylor, Lucas; Tkaczyk, Slawek; Tran, Nhan Viet; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vernieri, Caterina; Verzocchi, Marco; Vidal, Richard; Wang, Michael; Weber, Hannsjoerg Artur; Whitbeck, Andrew; Wu, Yujun; Acosta, Darin; Avery, Paul; Bortignon, Pierluigi; Bourilkov, Dimitri; Brinkerhoff, Andrew; Carnes, Andrew; Carver, Matthew; Curry, David; Das, Souvik; Field, Richard D; Furic, Ivan-Kresimir; Konigsberg, Jacobo; Korytov, Andrey; Low, Jia Fu; Ma, Peisen; Matchev, Konstantin; Mei, Hualin; Mitselmakher, Guenakh; Rank, Douglas; Shchutska, Lesya; Sperka, David; Thomas, Laurent; Wang, Jian; Wang, Sean-Jiun; Yelton, John; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Ackert, Andrew; Adams, Todd; Askew, Andrew; Bein, Samuel; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Prosper, Harrison; Santra, Arka; Yohay, Rachel; Baarmand, Marc M; Bhopatkar, Vallary; Colafranceschi, Stefano; Hohlmann, Marcus; Noonan, Daniel; Roy, Titas; Yumiceva, Francisco; Adams, Mark Raymond; Apanasevich, Leonard; Berry, Douglas; Betts, Russell Richard; Bucinskaite, Inga; Cavanaugh, Richard; Evdokimov, Olga; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Jung, Kurt; Sandoval Gonzalez, Irving Daniel; Varelas, Nikos; Wang, Hui; Wu, Zhenbin; Zakaria, Mohammed; Zhang, Jingyu; Bilki, Burak; Clarida, Warren; Dilsiz, Kamuran; Durgut, Süleyman; Gandrajula, Reddy Pratap; Haytmyradov, Maksat; Khristenko, Viktor; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Ogul, Hasan; Onel, Yasar; Ozok, Ferhat; Penzo, Aldo; Snyder, Christina; Tiras, Emrah; Wetzel, James; Yi, Kai; Anderson, Ian; Blumenfeld, Barry; Cocoros, Alice; Eminizer, Nicholas; Fehling, David; Feng, Lei; Gritsan, Andrei; Maksimovic, Petar; Roskes, Jeffrey; Sarica, Ulascan; Swartz, Morris; Xiao, Meng; Xin, Yongjie; You, Can; Al-bataineh, Ayman; Baringer, Philip; Bean, Alice; Boren, Samuel; Bowen, James; Castle, James; Forthomme, Laurent; Kenny III, Raymond Patrick; Khalil, Sadia; Kropivnitskaya, Anna; Majumder, Devdatta; Mcbrayer, William; Murray, Michael; Sanders, Stephen; Stringer, Robert; Tapia Takaki, Daniel; Wang, Quan; Ivanov, Andrew; Kaadze, Ketino; Maravin, Yurii; Mohammadi, Abdollah; Saini, Lovedeep Kaur; Skhirtladze, Nikoloz; Toda, Sachiko; Rebassoo, Finn; Wright, Douglas; Anelli, Christopher; Baden, Drew; Baron, Owen; Belloni, Alberto; Calvert, Brian; Eno, Sarah Catherine; Ferraioli, Charles; Gomez, Jaime; Hadley, Nicholas John; Jabeen, Shabnam; Jeng, Geng-Yuan; Kellogg, Richard G; Kolberg, Ted; Kunkle, Joshua; Mignerey, Alice; Ricci-Tam, Francesca; Shin, Young Ho; Skuja, Andris; Tonjes, Marguerite; Tonwar, Suresh C; Abercrombie, Daniel; Allen, Brandon; Apyan, Aram; Azzolini, Virginia; Barbieri, Richard; Baty, Austin; Bi, Ran; Bierwagen, Katharina; Brandt, Stephanie; Busza, Wit; Cali, Ivan Amos; D'Alfonso, Mariarosaria; Demiragli, Zeynep; Di Matteo, Leonardo; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hsu, Dylan; Iiyama, Yutaro; Innocenti, Gian Michele; Klute, Markus; Kovalskyi, Dmytro; Krajczar, Krisztian; Lai, Yue Shi; Lee, Yen-Jie; Levin, Andrew; Luckey, Paul David; Maier, Benedikt; Marini, Andrea Carlo; Mcginn, Christopher; Mironov, Camelia; Narayanan, Siddharth; Niu, Xinmei; Paus, Christoph; Roland, Christof; Roland, Gunther; Salfeld-Nebgen, Jakob; Stephans, George; Tatar, Kaya; Varma, Mukund; Velicanu, Dragos; Veverka, Jan; Wang, Jing; Wang, Ta-Wei; Wyslouch, Bolek; Yang, Mingming; Benvenuti, Alberto; Chatterjee, Rajdeep Mohan; Evans, Andrew; Hansen, Peter; Kalafut, Sean; Kao, Shih-Chuan; Kubota, Yuichi; Lesko, Zachary; Mans, Jeremy; Nourbakhsh, Shervin; Ruckstuhl, Nicole; Rusack, Roger; Tambe, Norbert; Turkewitz, Jared; Acosta, John Gabriel; Oliveros, Sandra; Avdeeva, Ekaterina; Bloom, Kenneth; Claes, Daniel R; Fangmeier, Caleb; Gonzalez Suarez, Rebeca; Kamalieddin, Rami; Kravchenko, Ilya; Malta Rodrigues, Alan; Monroy, Jose; Siado, Joaquin Emilo; Snow, Gregory R; Stieger, Benjamin; Alyari, Maral; Dolen, James; Godshalk, Andrew; Harrington, Charles; Iashvili, Ia; Kaisen, Josh; Nguyen, Duong; Parker, Ashley; Rappoccio, Salvatore; Roozbahani, Bahareh; Alverson, George; Barberis, Emanuela; Hortiangtham, Apichart; Massironi, Andrea; Morse, David Michael; Nash, David; Orimoto, Toyoko; Teixeira De Lima, Rafael; Trocino, Daniele; Wang, Ren-Jie; Wood, Darien; Bhattacharya, Saptaparna; Charaf, Otman; Hahn, Kristan Allan; Kumar, Ajay; Mucia, Nicholas; Odell, Nathaniel; Pollack, Brian; Schmitt, Michael Henry; Sung, Kevin; Trovato, Marco; Velasco, Mayda; Dev, Nabarun; Hildreth, Michael; Hurtado Anampa, Kenyi; Jessop, Colin; Karmgard, Daniel John; Kellams, Nathan; Lannon, Kevin; Marinelli, Nancy; Meng, Fanbo; Mueller, Charles; Musienko, Yuri; Planer, Michael; Reinsvold, Allison; Ruchti, Randy; Rupprecht, Nathaniel; Smith, Geoffrey; Taroni, Silvia; Wayne, Mitchell; Wolf, Matthias; Woodard, Anna; Alimena, Juliette; Antonelli, Louis; Bylsma, Ben; Durkin, Lloyd Stanley; Flowers, Sean; Francis, Brian; Hart, Andrew; Hill, Christopher; Hughes, Richard; Ji, Weifeng; Liu, Bingxuan; Luo, Wuming; Puigh, Darren; Winer, Brian L; Wulsin, Howard Wells; Cooperstein, Stephane; Driga, Olga; Elmer, Peter; Hardenbrook, Joshua; Hebda, Philip; Lange, David; Luo, Jingyu; Marlow, Daniel; Medvedeva, Tatiana; Mei, Kelvin; Ojalvo, Isabel; Olsen, James; Palmer, Christopher; Piroué, Pierre; Stickland, David; Svyatkovskiy, Alexey; Tully, Christopher; Malik, Sudhir; Barker, Anthony; Barnes, Virgil E; Folgueras, Santiago; Gutay, Laszlo; Jha, Manoj; Jones, Matthew; Jung, Andreas Werner; Khatiwada, Ajeeta; Miller, David Harry; Neumeister, Norbert; Schulte, Jan-Frederik; Shi, Xin; Sun, Jian; Wang, Fuqiang; Xie, Wei; Parashar, Neeti; Stupak, John; Adair, Antony; Akgun, Bora; Chen, Zhenyu; Ecklund, Karl Matthew; Geurts, Frank JM; Guilbaud, Maxime; Li, Wei; Michlin, Benjamin; Northup, Michael; Padley, Brian Paul; Roberts, Jay; Rorie, Jamal; Tu, Zhoudunming; Zabel, James; Betchart, Burton; Bodek, Arie; de Barbaro, Pawel; Demina, Regina; Duh, Yi-ting; Ferbel, Thomas; Galanti, Mario; Garcia-Bellido, Aran; Han, Jiyeon; Hindrichs, Otto; Khukhunaishvili, Aleko; Lo, Kin Ho; Tan, Ping; Verzetti, Mauro; Agapitos, Antonis; Chou, John Paul; Gershtein, Yuri; Gómez Espinosa, Tirso Alejandro; Halkiadakis, Eva; Heindl, Maximilian; Hughes, Elliot; Kaplan, Steven; Kunnawalkam Elayavalli, Raghav; Kyriacou, Savvas; Lath, Amitabh; Nash, Kevin; Osherson, Marc; Saka, Halil; Salur, Sevil; Schnetzer, Steve; Sheffield, David; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Thomassen, Peter; Walker, Matthew; Delannoy, Andrés G; Foerster, Mark; Heideman, Joseph; Riley, Grant; Rose, Keith; Spanier, Stefan; Thapa, Krishna; Bouhali, Othmane; Celik, Ali; Dalchenko, Mykhailo; De Mattia, Marco; Delgado, Andrea; Dildick, Sven; Eusebi, Ricardo; Gilmore, Jason; Huang, Tao; Juska, Evaldas; Kamon, Teruki; Mueller, Ryan; Pakhotin, Yuriy; Patel, Rishi; Perloff, Alexx; Perniè, Luca; Rathjens, Denis; Safonov, Alexei; Tatarinov, Aysen; Ulmer, Keith; Akchurin, Nural; Cowden, Christopher; Damgov, Jordan; De Guio, Federico; Dragoiu, Cosmin; Dudero, Phillip Russell; Faulkner, James; Gurpinar, Emine; Kunori, Shuichi; Lamichhane, Kamal; Lee, Sung Won; Libeiro, Terence; Peltola, Timo; Undleeb, Sonaina; Volobouev, Igor; Wang, Zhixing; Greene, Senta; Gurrola, Alfredo; Janjam, Ravi; Johns, Willard; Maguire, Charles; Melo, Andrew; Ni, Hong; Sheldon, Paul; Tuo, Shengquan; Velkovska, Julia; Xu, Qiao; Arenton, Michael Wayne; Barria, Patrizia; Cox, Bradley; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Li, Hengne; Neu, Christopher; Sinthuprasith, Tutanon; Sun, Xin; Wang, Yanchu; Wolfe, Evan; Xia, Fan; Clarke, Christopher; Harr, Robert; Karchin, Paul Edmund; Sturdy, Jared; Belknap, Donald; Buchanan, James; Caillol, Cécile; Dasu, Sridhara; Dodd, Laura; Duric, Senka; Gomber, Bhawna; Grothe, Monika; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Lanaro, Armando; Levine, Aaron; Long, Kenneth; Loveless, Richard; Perry, Thomas; Pierro, Giuseppe Antonio; Polese, Giovanni; Ruggles, Tyler; Savin, Alexander; Smith, Nicholas; Smith, Wesley H; Taylor, Devin; Woods, Nathaniel

    2017-04-21

    The CMS tracker consists of 206 m$^2$ of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from $-25$ to $+25^\\circ$C. The mechanical stability of tracker components during physics operation was monitored with a few $\\mu$m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30$ \\mu$m. In addition, temperature variations were found to cause displacements of tracker structures of about 2$\\mu$m/$^\\circ$C, which largely revert to their initial positions when the temperature is restored to its original value.

  14. Frequency tracking and stabilization of a tunable dual-wavelength external-cavity diode laser

    Science.gov (United States)

    Hsu, L.; Chi, L. C.; Wang, S. C.; Pan, Ci-Ling

    1999-09-01

    We show a unique dual-wavelength external-cavity laser diode with frequency tracking capability and obtain a stable beat frequency between the dual-wavelength output. By using a Fabry-Perot interferometer as the frequency discriminator and the time-gating technique in a servo loop, the peak-to-peak frequency fluctuations were stabilized, with respect to the Fabry-Perot cavity, to 86 kHz in the dual-wavelength output at 802.5 and 804.5 nm, and to 17 kHz in their 0.9 THz beat signal. Similar performance was achieved for tuning of the dual wavelength separation ranging from 0.2 to 4 nm.

  15. Intraoperative laser speckle contrast imaging improves the stability of rodent middle cerebral artery occlusion model

    Science.gov (United States)

    Yuan, Lu; Li, Yao; Li, Hangdao; Lu, Hongyang; Tong, Shanbao

    2015-09-01

    Rodent middle cerebral artery occlusion (MCAO) model is commonly used in stroke research. Creating a stable infarct volume has always been challenging for technicians due to the variances of animal anatomy and surgical operations. The depth of filament suture advancement strongly influences the infarct volume as well. We investigated the cerebral blood flow (CBF) changes in the affected cortex using laser speckle contrast imaging when advancing suture during MCAO surgery. The relative CBF drop area (CBF50, i.e., the percentage area with CBF less than 50% of the baseline) showed an increase from 20.9% to 69.1% when the insertion depth increased from 1.6 to 1.8 cm. Using the real-time CBF50 marker to guide suture insertion during the surgery, our animal experiments showed that intraoperative CBF-guided surgery could significantly improve the stability of MCAO with a more consistent infarct volume and less mortality.

  16. Thermal stability of amorphous carbon films grown by pulsed laser deposition

    Science.gov (United States)

    Friedmann, T. A.; McCarty, K. F.; Barbour, J. C.; Siegal, M. P.; Dibble, Dean C.

    1996-03-01

    The thermal stability in vacuum of amorphous tetrahedrally coordinated carbon (a-tC) films grown on Si has been assessed by in situ Raman spectroscopy. Films were grown in vacuum on room-temperature substrates using laser fluences of 12, 22, and 45 J/cm2 and in a background gas of either hydrogen or nitrogen using a laser fluence of 45 J/cm2. The films grown in vacuum at high fluence (≳20J/cm2) show little change in the a-tC Raman spectra with temperature up to 800 °C. Above this temperature the films convert to glassy carbon (nanocrystalline graphite). Samples grown in vacuum at lower fluence or in a background gas (H2 or N2) at high fluence are not nearly as stable. For all samples, the Raman signal from the Si substrate (observed through the a-tC film) decreases in intensity with annealing temperature indicating that the transparency of the a-tC films is decreasing with temperature. These changes in transparency begin at much lower temperatures (˜200 °C) than the changes in the a-tC Raman band shape and indicate that subtle changes are occurring in the a-tC films at lower temperatures.

  17. SUNLITE program. Sub-Hertz relative frequency stabilization of two diode laser pumped Nd:YAG lasers locked to a Fabry-Perot interferometer

    Science.gov (United States)

    Byer, R. L.

    1990-01-01

    Two laser pumped Nd:YAG lasers were frequency stabilized to a commercial 6.327 GHz free spectral range Fabry-Perot interferometer yielding a best case beatnote linewidth of 330 MHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27,500 was built, and when it was substituted in place of the commercial interferometer, it produced a robust and easily repeatable beatnote linewidth of 700 MHz.

  18. Sub-hertz relative frequency stabilization of two-diode laser-pumped Nd:YAG lasers locked to a Fabry-Perot interferometer

    Science.gov (United States)

    Day, Timothy; Gustafson, Eric K.; Byer, Robert L.

    1992-01-01

    Two-diode laser-pumped Nd:YAG lasers have been frequency stabilized to a commercial 6.327-GHz free spectral range Fabry-Perot interferometer yielding a best-case beatnote linewidth of 330 mHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27,500 has been built, and when substituted in place of the commercial interferometer produced a robust and easily repeatable beatnote linewidth of 700 MHz.

  19. Investigations of repetition rate stability of a mode-locked quantum dot semiconductor laser in an auxiliary optical fiber cavity

    DEFF Research Database (Denmark)

    Breuer, Stefan; Elsässer, Wolfgang; McInerney, J.G.

    2010-01-01

    We have investigated experimentally the pulse train (mode beating) stability of a monolithic mode-locked multi-section quantum-dot laser with an added passive auxiliary optical fiber cavity. Addition of the weakly coupled (¿ -24dB) cavity reduces the current-induced shift d¿/dI of the principal...

  20. Active frequency stabilization of a 1.062-micron, Nd:GGG, diode-laser-pumped nonplanar ring oscillator to less than 3 Hz of relative linewidth

    Science.gov (United States)

    Day, T.; Gustafson, E. K.; Byer, R. L.

    1990-01-01

    Results are presented on the frequency stabilization of two diode-laser-pumped ring lasers that are independently locked to the same high-finesse interferometer. The relative frequency stability is measured by locking the lasers one free spectral range apart and observing the heterodyne beat note. The resultant beat note width of 2.9 Hz is consistent with the theoretical system noise-limited linewidth and is approximately 20 times that expected for shot-noise-limited performance.

  1. Note: Space qualified photon counting detector for laser time transfer with picosecond precision and stability.

    Science.gov (United States)

    Prochazka, Ivan; Kodet, Jan; Blazej, Josef

    2016-05-01

    The laser time transfer link is under construction for the European Space Agency in the frame of Atomic Clock Ensemble in Space. We have developed and tested the flying unit of the photon counting detector optimized for this space mission. The results are summarized in this Note. An extreme challenge was to build a detector package, which is rugged, small and which provides long term detection delay stability on picosecond level. The device passed successfully all the tests required for space missions on the low Earth orbits. The detector is extremely rugged and compact. Its long term detection delay stability is excellent, it is better than ±1 ps/day, in a sense of time deviation it is better than 0.5 ps for averaging times of 2000 s to several hours. The device is capable to operate in a temperature range of -55 °C up to +60 °C, the change of the detection delay with temperature is +0.5 ps/K. The device is ready for integration into the space structure now.

  2. Multielectron effects in the photoelectron momentum distribution of noble-gas atoms driven by visible-to-infrared-frequency laser pulses: A time-dependent density-functional-theory approach

    Science.gov (United States)

    Murakami, Mitsuko; Zhang, G. P.; Chu, Shih-I.

    2017-05-01

    We present the photoelectron momentum distributions (PMDs) of helium, neon, and argon atoms driven by a linearly polarized, visible (527-nm) or near-infrared (800-nm) laser pulse (20 optical cycles in duration) based on the time-dependent density-functional theory (TDDFT) under the local-density approximation with a self-interaction correction. A set of time-dependent Kohn-Sham equations for all electrons in an atom is numerically solved using the generalized pseudospectral method. An effect of the electron-electron interaction driven by a visible laser field is not recognizable in the helium and neon PMDs except for a reduction of the overall photoelectron yield, but there is a clear difference between the PMDs of an argon atom calculated with the frozen-core approximation and TDDFT, indicating an interference of its M -shell wave functions during the ionization. Furthermore, we find that the PMDs of degenerate p states are well separated in intensity when driven by a near-infrared laser field, so that the single-active-electron approximation can be adopted safely.

  3. Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

    Science.gov (United States)

    Goymen, Merve; Isman, Eren; Taner, Lale; Kurkcu, Mehmet

    2015-01-01

    The purpose of this study was to evaluate the effects of different laser dose and force levels on the stability of orthodontic mini screws used for anchorage, by histomorphometric analyses. Low-level laser therapy speeds up blood flow, improves the mechanism of the revitalization processes, reduces the risk of infection, boosts metabolic activities, and accelerates the healing of the damaged tissue. Although there are many research studies about low-level laser therapy applications in a variety of areas, no investigations were found concerning mini screw stability using various laser dose levels with different force level applications. Seventeen New Zealand white rabbits were used. A total of 68 cylindrical, self-drilling orthodontic mini screws were threaded at the fibula. Experimental subjects were divided into six groups; force application was not performed in the first three groups, whereas 150 g of force was applied via nickel-titanium closed-coil springs placed between two mini screws in the other three groups. Measurements of the initial torque values (10 Ncm) were manipulated by a digital portable torque gauge. Various low-level laser doses were applied to the groups during the postoperative 10 days. After 4 weeks, bone-to-implant contact and cortical bone thickness were histomorphometrically analyzed. In the 150 g force plus 20 J/cm(2) dosage group, the highest bone-to-implant contact values were observed. (p0.05). Low-level laser therapy was noticed to induce the mini screw-bone contact area. Low-level laser therapy may be a supplementary treatment method to increase the stability of the orthodontic mini screw.

  4. Efficacy of multiple exposure with low level He-Ne laser dose on acute wound healing: a pre-clinical study

    Science.gov (United States)

    Prabhu, Vijendra; Rao, Bola Sadashiva S.; Mahato, Krishna Kishore

    2014-02-01

    Investigations on the use of Low Level Laser Therapy (LLLT) for wound healing especially with the red laser light have demonstrated its pro-healing potential on a variety of pre-clinical and surgical wounds. However, until now, in LLLT the effect of multiple exposure of low dose laser irradiation on acute wound healing on well-designed pre-clinical model is not much explored. The present study aimed to investigate the effect of multiple exposure of low dose Helium Neon laser on healing progression of full thickness excision wounds in Swiss albino mice. Further, the efficacy of the multiple exposure of low dose laser irradiation was compared with the single exposure of optimum dose. Full thickness excision wounds (circular) of 15 mm diameter were created, and subsequently illuminated with the multiple exposures (1, 2, 3, 4 and 5 exposure/ week until healing) of He-Ne (632.8 nm, 4.02 mWcm-2) laser at 0.5 Jcm-2 along with single exposure of optimum laser dose (2 J/cm-2) and un-illuminated controls. Classical biophysical parameters such as contraction kinetics, area under the curve and the mean healing time were documented as the assessment parameters to examine the efficacy of multiple exposures with low level laser dose. Experimental findings substantiated that either single or multiple exposures of 0.5 J/cm2 failed to produce any detectable alterations on wound contraction, area under the curve and mean healing time compared to single exposure of optimum dose (2 Jcm-2) and un-illuminated controls. Single exposure of optimum, laser dose was found to be ideal for acute wound healing.

  5. Indirect high-bandwidth stabilization of carrier-envelope phase of a high-energy, low-repetition-rate laser.

    Science.gov (United States)

    Fu, Yuxi; Takahashi, Eiji J; Midorikawa, Katsumi

    2016-06-13

    We demonstrate a method of stabilizing the carrier-envelope phase (CEP) of low-repetition-rate, high-energy femtosecond laser systems such as TW-PW class lasers. A relatively weak high-repetition-rate (~1 kHz) reference pulse copropagates with a low-repetition-rate (10 Hz) high-energy pulse, which are s- and p-polarized, respectively. Using a Brewster angle window, the reference pulse is separated after the power amplifier and used for feedback to stabilize its CEP. The single-shot CEP of the high-energy pulse is indirectly stabilized to 550 mrad RMS, which is the highest CEP stability ever reported for a low-repetition-rate (10-Hz) high-energy laser system. In this novel method, the feedback frequency of the reference pulse from the front-end preamplifier can be almost preserved. Thus, higher CEP stability can be realized than for lower frequencies. Of course, a reference pulse with an even higher repetition rate (e.g., 10 kHz) can be easily employed to sample and feed back CEP jitter over a broader frequency bandwidth.

  6. Frequency stabilization of distributed-feedback laser diodes at 1572 nm for lidar measurements of atmospheric carbon dioxide.

    Science.gov (United States)

    Numata, Kenji; Chen, Jeffrey R; Wu, Stewart T; Abshire, James B; Krainak, Michael A

    2011-03-01

    We demonstrate a wavelength-locked laser source that rapidly steps through six wavelengths distributed across a 1572.335 nm carbon dioxide (CO(2)) absorption line to allow precise measurements of atmospheric CO(2) absorption. A distributed-feedback laser diode (DFB-LD) was frequency-locked to the CO(2) line center by using a frequency modulation technique, limiting its peak-to-peak frequency drift to 0.3 MHz at 0.8 s averaging time over 72 hours. Four online DFB-LDs were then offset locked to this laser using phase-locked loops, retaining virtually the same absolute frequency stability. These online and two offline DFB-LDs were subsequently amplitude switched and combined. This produced a precise wavelength-stepped laser pulse train, to be amplified for CO(2) measurements. © 2011 Optical Society of America

  7. Robust method for long-term energy and pointing stabilization of high energy, high average power solid state lasers.

    Science.gov (United States)

    Boge, Robert; Horáček, Jakub; Mazůrek, Petr; Naylon, Jack A; Green, Jonathan T; Hubka, Zbyněk; Šobr, Václav; Novák, Jakub; Batysta, František; Antipenkov, Roman; Bakule, Pavel; Rus, Bedřich

    2018-02-01

    A robust and simple method is presented for ensuring constant energy and pointing of a high average power solid state laser on a target. In addition to providing long-term stability, this scheme also eliminates any drifts in energy or pointing resulting from the initial warm-up after a cold start. This is achieved using two separate feedback loops: one loop stabilizes the pointing of the beam external to the amplifier cavity and the other locks the cavity mode to have optimum overlap with the pump spot on the active medium. The key idea of the cavity mode stabilization is to monitor the overlap of the cavity mode and the gain medium with a camera and control it with an actively controlled, intra-cavity mirror. While this method is demonstrated on a thin-disk regenerative amplifier, it can also be applied to a wide variety of solid state laser amplifiers.

  8. Robust method for long-term energy and pointing stabilization of high energy, high average power solid state lasers

    Science.gov (United States)

    Boge, Robert; Horáček, Jakub; Mazůrek, Petr; Naylon, Jack A.; Green, Jonathan T.; Hubka, Zbyněk; Šobr, Václav; Novák, Jakub; Batysta, František; Antipenkov, Roman; Bakule, Pavel; Rus, Bedřich

    2018-02-01

    A robust and simple method is presented for ensuring constant energy and pointing of a high average power solid state laser on a target. In addition to providing long-term stability, this scheme also eliminates any drifts in energy or pointing resulting from the initial warm-up after a cold start. This is achieved using two separate feedback loops: one loop stabilizes the pointing of the beam external to the amplifier cavity and the other locks the cavity mode to have optimum overlap with the pump spot on the active medium. The key idea of the cavity mode stabilization is to monitor the overlap of the cavity mode and the gain medium with a camera and control it with an actively controlled, intra-cavity mirror. While this method is demonstrated on a thin-disk regenerative amplifier, it can also be applied to a wide variety of solid state laser amplifiers.

  9. A novel method for soil aggregate stability measurement by laser granulometry with sonication

    Science.gov (United States)

    Rawlins, B. G.; Lark, R. M.; Wragg, J.

    2012-04-01

    Regulatory authorities need to establish rapid, cost-effective methods to measure soil physical indicators - such as aggregate stability - which can be applied to large numbers of soil samples to detect changes of soil quality through monitoring. Limitations of sieve-based methods to measure the stability of soil macro-aggregates include: i) the mass of stable aggregates is measured, only for a few, discrete sieve/size fractions, ii) no account is taken of the fundamental particle size distribution of the sub-sampled material, and iii) they are labour intensive. These limitations could be overcome by measurements with a Laser Granulometer (LG) instrument, but this technology has not been widely applied to the quantification of aggregate stability of soils. We present a novel method to quantify macro-aggregate (1-2 mm) stability. We measure the difference between the mean weight diameter (MWD; μm) of aggregates that are stable in circulating water of low ionic strength, and the MWD of the fundamental particles of the soil to which these aggregates are reduced by sonication. The suspension is circulated rapidly through a LG analytical cell from a connected vessel for ten seconds; during this period hydrodynamic forces associated with the circulating water lead to the destruction of unstable aggregates. The MWD of stable aggregates is then measured by LG. In the next step, the aggregates - which are kept in the vessel at a minimal water circulation speed - are subject to sonication (18W for ten minutes) so the vast majority of the sample is broken down into its fundamental particles. The suspension is then recirculated rapidly through the LG and the MWD measured again. We refer to the difference between these two measurements as disaggregation reduction (DR) - the reduction in MWD on disaggregation by sonication. Soil types with more stable aggregates have larger values of DR. The stable aggregates - which are resistant to both slaking and mechanical breakdown by the

  10. Stabilization of the Rayleigh-Taylor instability by convection in an ablatively accelerated laser plasma

    International Nuclear Information System (INIS)

    Bul'ko, A.B.; Liberman, M.A.

    1992-01-01

    The authors use the WKB-approximation to treat the problem of the stabilization by an inhomogeneous convective current of the Rayleigh-Taylor instability developing in the ablation zone when the plasma of laser targets is accelerated by ablation. The problem of the eigenvalues - the instability growth rates - is reduced to the solution of an algebraic equation with coefficients which depend on the structure of the unperturbed profiles of the hydrodynamic variables. They show for the practically important case of subsonic flow of an incompressible plasma that the instability growth rate vanishes for k = k o = max[2(g|∇lnρ|) 1/2 /v]. The condition for the self-consistency of the model is that the local Froude number be small in the region where the instability develops; however, comparison with numerical calculations shows that the model is also applicable in the case of rather steep density gradients when the Froude number is of order unity. 32 refs., 2 figs

  11. Preparation of Graphene Oxide Stabilized Nickel Nanoparticles with Thermal Effusivity Properties by Laser Ablation Method

    Directory of Open Access Journals (Sweden)

    Amir Reza Sadrolhosseini

    2013-01-01

    Full Text Available Nickel nanoparticles were dispersed uniformly in a graphene oxide solution, using a laser ablation technique with different ablation times that ranged from 5 to 20 minutes. The results indicate that the nickel nanoparticle sizes inside the graphene oxide decreased, and the volume fraction for the nickel nanoparticles in the graphene oxide increased with an increasing ablation time. Further, using Fourier Transform Infrared Spectroscopy, the nickel nanoparticles in the graphene oxide demonstrate greater stability from possible agglomeration when the nanoparticle was capped with oxygen from the carboxyl group of the graphene oxide. The thermal effusivity of the graphene oxide and nickel nanoparticle graphene oxide composite was measured using a photoacoustic technique. The concentration of graphene oxide shifted from 0.05 mg/L to 2 mg/L, and the thermal effusivity increased from 0.153 W·s1/2·cm−2·K−1 to 0.326 W·s1/2·cm−2·K−1. In addition, the thermal effusivity of the nickel nanoparticles graphene oxide composite increased with an increase in the volume fraction of nickel nanoparticles from 0.1612 W·s1/2·cm−2·K−1 to 0.228 W·s1/2·cm−2·K−1.

  12. Laser frequency stabilization and control of optical cavities with suspended mirrors for the VIRGO interferometric detector of gravitational waves

    International Nuclear Information System (INIS)

    Barsuglia, Matteo

    1999-01-01

    The VIRGO detector is an interferometer with 3 km Fabry-Perot cavities in the arms. It is aimed at the detection of gravitational radiation emitted by astrophysical sources. This thesis comprises two independent parts. The first part is devoted to the laser frequency stabilization. In the second one we present a study of a suspended cavity. We determine the impact of laser frequency fluctuations on the overall VIRGO sensitivity. We study the frequency stabilization of the interferometer considered as an ultra-stable standard and we evaluate the noise pertaining to different signals taken into consideration. A strategy of control is discussed. We then study the VIRGO mode-cleaner prototype, a 30 m suspended triangular cavity, for which we have developed a control in order to keep it locked. Finally, we characterize this cavity in terms of mode spectra, finesse and mechanical transfer functions. (author)

  13. Frequency stability and offset locking of a laser-diode-pumped Nd:YAG monolithic nonplanar ring oscillator

    Science.gov (United States)

    Kane, Thomas J.; Nilsson, Alan C.; Byer, Robert L.

    1987-01-01

    The frequency stability of laser-diode-pumped, monolithic Nd:YAG solid-state unidirectional nonplanar ring oscillators was studied by heterodyne measurements. CW single-axial- and transverse-mode power of 25 mW at 1064 nm was obtained at a slope efficiency of 19 percent. Two independent oscillators were offset-locked at 17 MHz with frequency fluctuations of less than + or - 40 kHz for periods of 8 min.

  14. Room temperature growth of biaxially aligned yttria-stabilized zirconia films on glass substrates by pulsed-laser deposition

    CERN Document Server

    Li Peng; Mazumder, J

    2003-01-01

    Room temperature deposition of biaxially textured yttria-stabilized zirconia (YSZ) films on amorphous glass substrates was successfully achieved by conventional pulsed-laser deposition. The influence of the surrounding gases, their pressure and the deposition time on the structure of the films was studied. A columnar growth process was revealed based on the experimental results. The grown biaxial texture appears as a kind of substrate independence, which makes it possible to fabricate in-plane aligned YSZ films on various substrates.

  15. A phase stabilized and pulse shaped Ti:Sapphire oscillator-amplifier laser system for the LCLS rf photoinjector

    International Nuclear Information System (INIS)

    Kotseroglou, T.; Alley, R.; Clendenin, J.; Fisher, A.; Frisch, J.

    1998-04-01

    The authors have designed a laser system for the Linac Coherent Light Source rf photoinjector consisting of a Ti:Sapphire oscillator and 2 amplifiers using Chirped Pulse Amplification. The output after tripling will be 0.5 mJ tunable UV pulses at 120 Hz, with wavelength around 260 nm, pulsewidth of 10 ps FWHM and 200 fs rise and fall times. Amplitude stability is expected to be 1% rms in the UV and timing jitter better than 500 fs rms

  16. 1.5 μm InAs/InGaAsP/InP quantum dot laser with improved temperature stability

    DEFF Research Database (Denmark)

    Zubov, F. I.; Gladii, S. P.; Shernyakov, Yu M.

    2016-01-01

    Temperature characteristics of InAs/InGaAsP quantum dot (QD) lasers synthesized on InP (001) substrate are presented. The lasers demonstrate high temperature stability: a threshold current characteristic temperature as high as 205 K in the temperature range between 20 to 50°C was measured. Lasing...

  17. Effect of laser radiation on the cultivation rate of the microalga Chlorella sorokiniana as a source of biofuel

    Science.gov (United States)

    Politaeva, N.; Smyatskaya, Y.; Slugin, V.; Toumi, A.; Bouabdelli, M.

    2018-01-01

    This article studies the influence of laser radiation on the growth of micro-algal biomass of Chlorella sorokiniana. The composition of nutrient medium and the effect the laser beam (2 and 5 cm diameter, 1, 5, 10, 15 and 20 minutes exposure time) for accelerated cultivation of microalgal biomass were studied. The source of laser radiation (LR) was a helium-neon laser with a nominal output power of 1.6 mW and a wavelength of 0.63 μm. The greatest increase in biomass was observed when LR was applied to a suspension of microalga Chlorella sorokiniana with a beam of 5 cm diameter for a time of 10, 15 and 20 minutes. The results of the microscopic study of the microalga cells show a significant increase in the number of cells after an exposure to LR with a beam diameter of 5 cm in diameter. These cells were characterized by a large vacuole, a thickened lipid shell and a large accumulation of metabolites prone to agglutination. This study proposed to obtain valuable components (lipids, carotenoids, and pectin) from the obtained biomass by extraction method and to use the residual biomass formed wastes, after the extraction of valuable components, as a co-substrate for anaerobic digestion to produce biogas. The composition of biogas consists mainly of methane and carbon dioxide. Methane is recommended to be used for economic needs in supplying the whole process with heat and electricity. The carbon dioxide formed during fermentation and after combustion of methane for energy production, is planned to be used as a carbon source in the cultivation of Chlorella sorokiniana for photoautotrophic biomass production.

  18. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Thorsten

    2017-05-15

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  19. Laser-to-RF phase detection with femtosecond precision for remote reference phase stabilization in particle accelerators

    International Nuclear Information System (INIS)

    Lamb, Thorsten

    2017-05-01

    The operation of modern free-electron lasers (FELs) requires the synchronization of different accelerator subsystems with femtosecond precision. A pulsed optical synchronization system is for this reason operated at the Free-Electron Laser in Hamburg (FLASH) and it is under construction for the upcoming European X-ray Free-Electron Laser (XFEL). Laser pulses from the optical master oscillator are transmitted by timing stabilized optical fiberlinks to dedicated end stations along the accelerator. Devices which cannot operate with optical synchronization signals are instead conventionally synchronized with radio frequency (RF) reference signals. These signals are distributed in the accelerator by coaxial cables. Especially the low -level radio frequency (LLRF) system requires RF reference signals with femtosecond stability in order to meet nowadays femtosecond demands. Due to cable drifts and the length of the accelerators, this level of stability cannot be provided by conventional RF transport. A laser-to-RF (L2RF) phase detector has been invented, which allows to measure with femtosecond precision the relative phase between a phase stable optical pulse train from an optical fiberlink and an RF signal. The L2RF phase detector is based on an integrated MACH-ZEHNDER modulator (MZM) in which the phase error between both signals is encoded in an amplitude modulation of the optical pulse train. Different configurations, based on single output and dual output MZMs have been evaluated for different operation scenarios. A full mathematical representation of the chosen configuration has been derived. The impact of multiple error sources has been investigated. It has been proven that most error sources have only second or higher order influence on the detection principle which is a significant advantage over existing schemes. The invented L2RF phase detector is for example balanced and in its working point insensitive to power variations of the optical reference pulse train

  20. AlGaAs/GaAs laser diode bars (λ = 808 nm) with improved thermal stability

    International Nuclear Information System (INIS)

    Marmalyuk, A A; Ladugin, M A; Andreev, A Yu; Telegin, K Yu; Yarotskaya, I V; Meshkov, A S; Konyaev, V P; Sapozhnikov, S M; Lebedeva, E I; Simakov, V A

    2013-01-01

    Two series of AlGaAs/GaAs laser heterostructures have been grown by metal-organic vapour phase epitaxy, and 808-nm laser diode bars fabricated from the heterostructures have been investigated. The heterostructures differed in waveguide thickness and quantum well depth. It is shown that increasing the barrier height for charge carriers in the active region has an advantageous effect on the output parameters of the laser sources in the case of the heterostructures with a narrow symmetric waveguide: the slope of their power – current characteristics increased from 0.9 to 1.05 W A -1 . Thus, the configuration with a narrow waveguide and deep quantum well is better suited for high-power laser diode bars under hindered heat removal conditions. (lasers)

  1. AlGaAs/GaAs laser diode bars (λ = 808 nm) with improved thermal stability

    Energy Technology Data Exchange (ETDEWEB)

    Marmalyuk, A A; Ladugin, M A; Andreev, A Yu; Telegin, K Yu; Yarotskaya, I V; Meshkov, A S; Konyaev, V P; Sapozhnikov, S M; Lebedeva, E I; Simakov, V A [Open Joint-Stock Company M.F. Stel' makh Polyus Research Institute, Moscow (Russian Federation)

    2013-10-31

    Two series of AlGaAs/GaAs laser heterostructures have been grown by metal-organic vapour phase epitaxy, and 808-nm laser diode bars fabricated from the heterostructures have been investigated. The heterostructures differed in waveguide thickness and quantum well depth. It is shown that increasing the barrier height for charge carriers in the active region has an advantageous effect on the output parameters of the laser sources in the case of the heterostructures with a narrow symmetric waveguide: the slope of their power – current characteristics increased from 0.9 to 1.05 W A{sup -1}. Thus, the configuration with a narrow waveguide and deep quantum well is better suited for high-power laser diode bars under hindered heat removal conditions. (lasers)

  2. Frequency Stabilization of DFB Laser Diodes at 1572 nm for Spaceborne Lidar Measurements of CO2

    Science.gov (United States)

    Numata, Kenji; Chen, Jeffrey R.; Wu, Stewart T.; Abshire, James B.; Krainak, Michael A.

    2010-01-01

    We report a fiber-based, pulsed laser seeder system that rapidly switches among 6 wavelengths across atmospheric carbon dioxide (CO2) absorption line near 1572.3 nm for measurements of global CO2 mixing ratios to 1-ppmv precision. One master DFB laser diode has been frequency-locked to the CO2 line center using a frequency modulation technique, suppressing its peak-to-peak frequency drifts to 0.3 MHz at 0.8 sec averaging time over 72 hours. Four online DFB laser diodes have been offset-locked to the master laser using phase locked loops, with virtually the same sub-MHz absolute accuracy. The 6 lasers were externally modulated and then combined to produce the measurement pulse train.

  3. Compensating microphonics in SRF cavities to ensure beam stability for future free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel

    2008-07-21

    In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02 in phase and up to 1.10{sup -4} in amplitude. For the planned BESSY-FEL it is envisaged to operate 144 superconducting 1.3 GHz cavities of the 2.3 GeV driver linac in continuous wave mode and at a low beam current. The cavity resonance comprises a very narrow bandwidth of the order of tens of Hertz. Such cavities have been characterized under accelerator like conditions in the HoBiCaT test facility. It was possible to measure the error sources affecting the field stability in continuous wave (CW) operation. Microphonics, the main error source for a mechanical detuning of the cavities, lead to an average fluctuation of the cavity resonance of 1-5 Hz rms. Furthermore, the static and dynamic Lorentz force detuning and the helium pressure dependance of the cavity resonance have been measured. Single cavity RF control and linac bunch-to-bunch longitudinal phase space modeling containing the measured properties showed, that it is advisable to find means to minimize the microphonics detuning by mechanical tuning. Thus, several fast tuning systems have been tested for CW operation. These tuners consist of a motor driven lever for slow and coarse tuning and a piezo that is integrated into the tuner support for fast and fine tuning. Regarding the analysis of the detuning spectrum an adaptive feedforward method based on the least-mean-square filter algorithm has been developed for fast cavity tuning. A detuning compensation between a factor of two and up to a factor of seven has been achieved. Modeling the complete system including the fast tuning scheme, showed that the requirements of the BESSY-FEL are attainable. (orig.)

  4. Preparation of submicron-sized spherical particles of gold using laser-induced melting in liquids and low-toxic stabilizing reagent

    International Nuclear Information System (INIS)

    Tsuji, T.; Higashi, Y.; Tsuji, M.; Ishikawa, Y.; Koshizaki, N.

    2015-01-01

    Highlights: • Submicron-sized spherical particles of gold were prepared using laser irradiation for the source gold nanoparticles stabilized by NaCl. • The source gold nanoparticles agglomeration was controlled both by the NaCl concentration of and by laser irradiation. • The formation process and the laser-fluence dependence of the particle size of gold nanoparticles in NaCl solutions differs from those in citrate solutions. • We revealed that properties of ligands are significantly important to prepare submicron-sized spherical particles and to control their size. - Abstract: Laser-induced melting in liquids (LIML) was applied to prepare spherical submicron-sized particles of gold (AuSMPs) from gold nanoparticles (AuNPs) stabilized using NaCl. Because undesirable byproducts, which might be generated when organic reagents such as citrate are used as the stabilizing reagent, are not generated from NaCl by laser irradiation, AuSMPs fabricated from AuNPs stabilized by NaCl will be low toxic. The AuSMPs were obtained by laser irradiation of the source AuNPs in NaCl solutions stabilized by NaCl at the proper concentration. Similar to the preparation of AuSMPs from AuNPs stabilized by citrate, the agglomeration of the source AuNPs, which is necessary to obtain AuSMPs, was controlled both by the NaCl concentration and by laser irradiation. However, the formation process and the laser-fluence dependence of the particle size of AuSMPs differed for various NaCl solutions and citrate solutions

  5. Endodontic applications of a short pulsed FR Nd:YAG dental laser: photovaporization of extruded pulpal tissue following traumatic fractures of two maxillary central incisors--a clinical trial repor

    Science.gov (United States)

    Gregg, Robert H., II

    1992-06-01

    Historically, many techniques have been attempted in the search for a satisfactory and consistent treatment of inflamed, painful, hyperemic pulpal tissue. Present techniques attempting to achieve profound local anesthesia in such tissue, have not been satisfactory. Local anesthesia techniques acceptable to the patient with painful hyperemic pulpal tissue, has eluded previous technology. The subsequent treatment of hyperemic tissue without sufficient anesthesia primarily involves undesirable invasive mechanical/surgical procedures. Described in this clinical trial is a technique using free running (FR) pulsed, Nd:YAG laser energy to ablate soft tooth pulpal tissue--a technique employed after conventional endodontic methods failed. A free running pulsed, FR Nd:YAG dental laser was successfully used at 20 pulses per second and 1.25 watts to photovaporize endodontic pulpal tissue (pulpectomy) to allow a conventional endodontic file to extirpate the remaining soft tissue remnants and access the root apex. Also described in this paper is the 'hot-tip' effect of contact fiber laser surgery. This clinical trial achieved the immediate, short term objective of endodontic soft tissue removal via photovaporization, without pain reported by the patient. The pulsed FR Nd:YAG dental laser used as described in this clinical report appears to be a very safe and very effective technique; offers a treatment alternative to traditional therapy that suggests high patient acceptance; and is significantly less stressful for the doctor and staff than traditional treatment options. Long-term, controlled scientific and clinical studies are necessary to establish the safety and efficacy of both the helium-neon energy for visualization and the low-watt pulsed FR Nd:YAG energy for photovaporization of soft endodontic pulpal tissue within the root canal. Research is especially needed to understand the effects of a low-watt, pulsed FR, Nd:YAG laser on the activity of osteoclasts and odontoclasts

  6. Low-loss smile-insensitive external frequency-stabilization of high power diode lasers enabled by vertical designs with extremely low divergence angle and high efficiency

    Science.gov (United States)

    Crump, Paul; Knigge, Steffen; Maaßdorf, Andre; Bugge, Frank; Hengesbach, Stefan; Witte, Ulrich; Hoffmann, Hans-Dieter; Köhler, Bernd; Hubrich, Ralf; Kissel, Heiko; Biesenbach, Jens; Erbert, Götz; Traenkle, Guenther

    2013-02-01

    Broad area lasers with narrow spectra are required for many pumping applications and for wavelength beam combination. Although monolithically stabilized lasers show high performance, some applications can only be addressed with external frequency stabilization, for example when very narrow spectra are required. When conventional diode lasers with vertical far field angle, ΘV 95% ~ 45° (95% power) are stabilized using volume holographic gratings (VHGs), optical losses are introduced, limiting both efficiency and reliable output power, with the presence of any bar smile compounding the challenge. Diode lasers with designs optimized for extremely low vertical divergence (ELOD lasers) directly address these challenges. The vertical far field angle in conventional laser designs is limited by the waveguiding of the active region itself. In ELOD designs, quantum barriers are used that have low refractive index, enabling the influence of the active region to be suppressed, leading to narrow far field operation from thin vertical structures, for minimal electrical resistance and maximum power conversion efficiency. We review the design process, and show that 975 nm diode lasers with 90 μm stripes that use ELOD designs operate with ΘV 95% = 26° and reach 58% power conversion efficiency at a CW output power of 10 W. We demonstrate directly that VHG stabilized ELOD lasers have significantly lower loss and larger operation windows than conventional lasers in the collimated feedback regimes, even in the presence of significant (≥ 1 μm) bar smile. We also discuss the potential influence of ELOD designs on reliable output power and options for further performance improvement.

  7. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  8. Stability and performance improvement of a polymer electrolyte membrane fuel cell stack by laser perforation of gas diffusion layers

    Energy Technology Data Exchange (ETDEWEB)

    Gerteisen, Dietmar; Sadeler, Christian [Fraunhofer Institute for Solar Energy Systems ISE, Department of Energy Technology, Heidenhofstrasse 2, 79110 Freiburg (Germany)

    2010-08-15

    The performance and stability of a hydrogen-driven polymer electrolyte membrane fuel cell stack (6-cell PEFC stack) are investigated with regard to pore flooding within the gas diffusion layers (GDLs). Two short stacks with various GDLs (Toray TGP-H-060 untreated and laser-perforated) were characterized at different operating conditions by several characterization techniques such as constant current load, polarization curve, chronoamperometry and chronovoltammetry. The experimental results reveal that the perforation of the cathode GDLs improves the water transport in the porous media and thus the performance as well as the stability of the operating stack in medium and high current density range. A reduced pore flooding is verified when using the customized laser-perforated GDLs. The GDL perforation has a huge potential to balance the inhomogeneous in-plane saturation conditions between the inlet and outlet area of the cell and to compensate to a certain degree the effects of temperature distribution within a stack regarding the water management. (author)

  9. Stability and performance improvement of a polymer electrolyte membrane fuel cell stack by laser perforation of gas diffusion layers

    Science.gov (United States)

    Gerteisen, Dietmar; Sadeler, Christian

    The performance and stability of a hydrogen-driven polymer electrolyte membrane fuel cell stack (6-cell PEFC stack) are investigated with regard to pore flooding within the gas diffusion layers (GDLs). Two short stacks with various GDLs (Toray TGP-H-060 untreated and laser-perforated) were characterized at different operating conditions by several characterization techniques such as constant current load, polarization curve, chronoamperometry and chronovoltammetry. The experimental results reveal that the perforation of the cathode GDLs improves the water transport in the porous media and thus the performance as well as the stability of the operating stack in medium and high current density range. A reduced pore flooding is verified when using the customized laser-perforated GDLs. The GDL perforation has a huge potential to balance the inhomogeneous in-plane saturation conditions between the inlet and outlet area of the cell and to compensate to a certain degree the effects of temperature distribution within a stack regarding the water management.

  10. Unified understanding of tunneling ionization and stabilization of atomic hydrogen in circularly and linearly polarized intense laser fields

    International Nuclear Information System (INIS)

    Miyagi, Haruhide; Someda, Kiyohiko

    2010-01-01

    On the basis of the Floquet formalism, the ionization mechanisms of atomic hydrogen in circularly and linearly polarized intense laser fields are discussed. By using the complex scaling method in the velocity gauge, the pole positions of the scattering-matrix on the complex quasienergy Riemann surface are calculated, and pole trajectories with respect to the variation of the laser intensity are obtained. In the low-frequency regime, the pole trajectory exhibits a smooth ponderomotive energy shift in the case of circular polarization. In contrast, the smoothness is lost in the case of linear polarization. In the high-frequency regime, the pole trajectories exhibit the stabilization phenomenon for both the types of polarization. These observations are elucidated by a unified picture based on the analysis of the adiabatic potentials for the radial motion of the electron in the acceleration gauge. The ionization in the case of circular polarization of the low-frequency regime is governed by the electron tunneling through a barrier of a single adiabatic potential. The stabilization in the high-frequency regime can be explained by the change in the avoided crossings among the adiabatic potential curves. The transition between the different frequency regimes is explicable by the change in the structure of the adiabatic potentials. The difference caused by the type of polarization is ascribable to the difference in the space-time symmetry.

  11. Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

    International Nuclear Information System (INIS)

    Masuda, Shin; Kanoh, Eiji; Irisawa, Akiyoshi; Niki, Shoji

    2009-01-01

    We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10 -8 (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

  12. A dye laser-cryogenic helium jet system and recoil-mass-separator for studies of nuclei far from stability

    CERN Document Server

    Clark, D L; Cormier, T M; Hermann, G; Lin, B S; Martin, A G; Nicolis, N G; Stwertka, P M

    1981-01-01

    Most of the recent applications of lasers to on-line measurements of hyperfine interactions and isotope shifts have been made using high energy proton beams to produce large fluxes of a wide range of unstable atoms. On-line mass separators select the atomic species of interest. At NSRL the authors have in the final stages of development an on-line laser spectroscopy system for the upgraded MP tandem. The system is based on the use of more selective heavy-ion reactions so that mass separation is not usually required, and very sensitive detection techniques so that measurements are possible with small fluxes of atoms. A recoil mass separator is also near completion and will be used for a variety of studies of nuclei far from stability, including providing, when necessary, mass separated reaction products for study using the laser system. The heavy ion beam energy available from the upgraded MP allows production of neutron deficient nuclei by means of fusion-evaporation reactions that is limited only by the onse...

  13. Lasers

    OpenAIRE

    Passeron, Thierry

    2012-01-01

    International audience; Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be succesfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-aulait macules should not b...

  14. Laser

    OpenAIRE

    Du, K.; Loosen, P.; Herziger, G.

    1991-01-01

    Laser, consisting of a beam path multiple-folded by means of two cavity end mirrors and having at least one reflector folding the laser beam retroreflectively, the axis of which is arranged offset in parallel to the axis of a further reflector. So that the laser exhibits an improved beam quality while retaining its comparatively low adjustment sensitivity, the beam path is folded at least twice by means of the retoreflective reflector.

  15. Stability of a laser cavity with non-parabolic phase transformation elements

    CSIR Research Space (South Africa)

    Litvin, IA

    2013-05-01

    Full Text Available aberration in high–power transversally pumped laser rods,” Opt. Commun. 259(1), 223–235 (2006). 14. A. G. Fox and T. Li, “Resonant Modes in a Maser Interferometer,” Bell Syst. Tech. J. 40, 453–488 (1961). 15. O. Svelto, Principles of Lasers, 3rd edition.... Consequently the intra-cavity implementation of any non-conventional phase transformation elements or taking into account the thermal lensing which in general has a non-parabolic phase transformation [13], leads to a solution of the complicated Fox...

  16. Efficiency and stability of a phosphor-conversion white light source using a blue laser diode

    Directory of Open Access Journals (Sweden)

    G. Ledru

    2014-10-01

    Full Text Available A white light source using direct phosphor-conversion excited by a blue laser diode is presented. In this preliminary study we have investigated the influence of phosphor’s thickness and operating current of the laser diode over the (x, y chromaticity coordinates, Correlated Color Temperature (CCT and Color Rendering Index (CRI. The best values found were 4000 K and 94. A 40 lm/W luminous efficacy was achieved together with a CRI close to 90 for an operating current of 0.8 A. Those values, to the best of our knowledge, were not previously reported in the literature.

  17. Stabilization of Au nanoparticles prepared by laser ablation in chloroform with free-base porphyrin molecules

    Czech Academy of Sciences Publication Activity Database

    Šišková, Karolína; Pfleger, Jiří; Procházka, M.

    2010-01-01

    Roč. 256, č. 9 (2010), s. 2979-2987 ISSN 0169-4332 R&D Projects: GA AV ČR KAN100500652; GA ČR GA203/07/0717 Institutional research plan: CEZ:AV0Z40500505 Keywords : Au nanoparticles * laser ablation * chloroform Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.795, year: 2010

  18. Flight-Like Optical Reference Cavity for GRACE Follow-On Laser Frequency Stabilization

    Science.gov (United States)

    Folkner, W. M.; deVine, G.; Klipstein, W. M.; McKenzie, K.; Spero, R.; Thompson, R.; Yu, N.; Stephens, M.; Leitch, J.; Pierce, R.; hide

    2011-01-01

    We describe a prototype optical cavity and associated optics that has been developed to provide a stable frequency reference for a future space-based laser ranging system. This instrument is being considered for inclusion as a technology demonstration on the recently announced GRACE follow-on mission, which will monitor variations in the Earth's gravity field.

  19. Foundations of a laser-accelerated plasma diagnostics and beam stabilization with miniaturized Rogowski coils

    Science.gov (United States)

    Gruenwald, J.; Kocoń, D.; Khikhlukha, D.

    2018-03-01

    In order to introduce spatially resolved measurements of the plasma density in a plasma accelerated by a laser, a novel concept is proposed in this work. We suggest the usage of an array of miniaturized Rogowski coils to measure the current contributions parallel to the laser beam with a spatial resolution in the sub-mm range. The principle of the experimental setup will be shown in 3-D CAD models. The coils are coaxial to the plasma channel (e.g. a hydrogen filled capillary, which is frequently used in laser-plasma acceleration experiments). This plasma diagnostics method is simple, robust and it is a passive measurement technique, which does not disturb the plasma itself. As such coils rely on a Biot-Savart inductivity, they allow to separate the contributions of the parallel from perpendicular currents (with respect to the laser beam). Rogowski coils do not have a ferromagnetic core. Hence, non-linear effects resulting from such a core are to be neglected, which increases the reliability of the obtained data. They also allow the diagnosis of transient signals that carry high currents (up to several hundred kA) on very short timescales. Within this paper some predictions about the time resolution of such coils will be presented along with simple theoretical considerations.

  20. Investigation of Atomic Physics and Frequency Stability with a Croygenic Hydrogen Laser

    National Research Council Canada - National Science Library

    Walsworth, Ronald

    1997-01-01

    .... The cryogenic hydrogen maser (CHM) operates at low temperatures, and may provide frequency stability that is one to three orders of magnitude better than a room temperature hydrogen maser because of greatly reduced thermal noise and larger signal power...

  1. Low-level laser irradiation alters mRNA expression from genes involved in DNA repair and genomic stabilization in myoblasts

    Science.gov (United States)

    Trajano, L. A. S. N.; Sergio, L. P. S.; Silva, C. L.; Carvalho, L.; Mencalha, A. L.; Stumbo, A. C.; Fonseca, A. S.

    2016-07-01

    Low-level lasers are used for the treatment of diseases in soft and bone tissues, but few data are available regarding their effects on genomic stability. In this study, we investigated mRNA expression from genes involved in DNA repair and genomic stabilization in myoblasts exposed to low-level infrared laser. C2C12 myoblast cultures in different fetal bovine serum concentrations were exposed to low-level infrared laser (10, 35 and 70 J cm-2), and collected for the evaluation of DNA repair gene expression. Laser exposure increased gene expression related to base excision repair (8-oxoguanine DNA glycosylase and apurinic/apyrimidinic endonuclease 1), nucleotide excision repair (excision repair cross-complementation group 1 and xeroderma pigmentosum C protein) and genomic stabilization (ATM serine/threonine kinase and tumor protein p53) in normal and low fetal bovine serum concentrations. Results suggest that genomic stability could be part of a biostimulation effect of low-level laser therapy in injured muscles.

  2. Stability of iodinated contrast media in UV-laser irradiation and toxicity of photoproducts

    International Nuclear Information System (INIS)

    Groenewaeller, E.F.; Kehlbach, R.; Claussen, C.D.; Duda, S.H.; Wahl, H.G.; Rodemann, H.P.

    1998-01-01

    Purpose: In XeCl-Excimer laser angioplasty, unintended and possibly harmful interaction of the UV-laser light and the contrast media may occur due to the high concentration of contrast medium proximal to the occlusion or subtotal stenosis. Methods: One ml of three nonionic monomeric contrast agents (iopromide, iomeprol, iopamidol), one nonionic dimetric (jotrolane), and one ionic monomeric (amidotrizoate) X-ray contrast agent were irradiated with a XeCl excimer laser (λ=308 nm, pulse duration 120 ns, 50 Hz) using a 9 French multifiber catheter (12 sectors). Up to 20 000 pulses (106 J) were applied. Using high performance liquid chromatography the amount of liberated iodide as well as the fraction of unchanged contrast media were measured. Cytotoxicity of the photoproducts was tested in a colony formation assay of human skin fibroblasts. The contrast agents were irradiated with 2000 pulses/ml (5.3 mJ/pulse; 10.6 J) and then added to the cell cultures for a period of three hours in a concentration of 10%. Results: Excimer laser irradiation induced iodide liberation of up to 3.3 mg iodide/ml. Up to 19% of the contrast agents changed their original molecular structure. Incubation of irradiated contrast agents resulted in a significantly decreased potential for colony formation (p values ranging from 0.0044 to 0.0102) with significantly higher toxicity of amidotrizoate and iomeprol in comparison to iopromide, iotrolan, and iopamidol. Discussion: Due to the cytotoxic photoproducts and the high level of liberated iodide, it is recommended to flush the artery with physiological saline solution before applying a pulsed excimer laser in human arterial obstructions in order to reduce the contrast agent concentration at the site of irradiation. (orig.) [de

  3. Role of diagnostic testing in identifying and resolving dimensional-stability problems in electroplated laser mirrors

    International Nuclear Information System (INIS)

    Cutler, R.L.; Hogan, B.

    1982-01-01

    The metal mirrors which are the subject of this discussion are to be used in the Antares inertial fusion laser system. Antares is a high-power (40 TW), high-energy (35 to 40 kJ), pulsed CO 2 laser system for the investigation of inertial confinement fusion. The system contains more than four hundred small and large diamond-turned and conventionally polished mirrors. The largest mirrors are trapezoidal in shape with the longest dimension being 16 to 18 inches. The substrates are type 2124 aluminum for most large mirrors, and aluminum bronze, oxygen-free copper or a copper-zirconium alloy for most of the smaller mirrors. The optical surface is electro-deposited copper 20 to 40 mils thick. After nondestructive testing and rough machining, the electroplated surface is single-point diamond machined or conventionally polished

  4. Preparation of Graphene Oxide Stabilized Nickel Nanoparticles with Thermal Effusivity Properties by Laser Ablation Method

    OpenAIRE

    Sadrolhosseini, Amir Reza; Noor, A. S. M.; Shameli, Kamyar; Kharazmi, Alireza; Huang, N. M.; Mahdi, M. A.

    2013-01-01

    Nickel nanoparticles were dispersed uniformly in a graphene oxide solution, using a laser ablation technique with different ablation times that ranged from 5 to 20 minutes. The results indicate that the nickel nanoparticle sizes inside the graphene oxide decreased, and the volume fraction for the nickel nanoparticles in the graphene oxide increased with an increasing ablation time. Further, using Fourier Transform Infrared Spectroscopy, the nickel nanoparticles in the graphene oxide demonstra...

  5. Laser welding of pre-functionalized glass substrates: a fabrication and chemical stability study

    Science.gov (United States)

    Carvalho, R. R.; Reuvekamp, S.; Zuilhof, H.; Blom, M. T.; Vrouwe, E. X.

    2018-01-01

    Low-temperature bonding of glass substrates is of great interest in the field of microfluidic-based biosensing, and we study how laser welding could be used for this. This technology allows for the modification of glass channels with temperature-sensitive materials prior to bonding. We study the effects of the welding process by investigation of the thermal degradation of a biotin monolayer and whether it retains the ability to conjugate with fluorescently-labelled streptavidin.

  6. Frequency and timing stability of an airborne injection-seeded Nd:YAG laser system for direct-detection wind lidar.

    Science.gov (United States)

    Lemmerz, Christian; Lux, Oliver; Reitebuch, Oliver; Witschas, Benjamin; Wührer, Christian

    2017-11-10

    We report on the design and performance of the laser deployed in the airborne demonstrator Doppler wind lidar for the Aeolus mission of the European Space Agency (ESA). The all-solid-state, diode-pumped and frequency-tripled Nd:YAG laser is realized as a master oscillator power amplifier (MOPA) system, generating 60 mJ of single-frequency pulses at 355 nm wavelength, 50 Hz repetition rate and 20 ns pulse duration. For the measurement of the Doppler frequency shift over several accumulated laser shots, the frequency stability of the laser is of crucial importance. Injection-seeding, in combination with an active cavity control based on the Ramp-Delay-Fire technique, provides a pulse-to-pulse frequency stability of 0.25 MHz measured at 1064 nm under laboratory conditions. This value increases to 0.31 MHz for airborne operation in a vibration environment that has been characterized by multiple acceleration sensors during different flight conditions. In addition, a pure Ramp-Fire setting was tested for comparison leading to a frequency stability of 0.16 MHz both in airborne operation and on ground. The laser cavity control electronics also have to provide a trigger signal for the lidar detection electronics, about 60 μs prior to the expected laser pulse emission and with high timing stability. An in-flight timing stability of below 100 ns was measured decreasing to 20 ns for a shorter pre-trigger time of 10 μs.

  7. Characterization of yttria-stabilized zirconia thin films grown by pulsed laser deposition (PLD) on various substrates

    International Nuclear Information System (INIS)

    Rodrigo, K.; Knudsen, J.; Pryds, N.; Schou, J.; Linderoth, S.

    2007-01-01

    Films of yttria-stabilized zirconia (YSZ) were deposited on substrates of various surface types by pulsed laser deposition (PLD). We have investigated formation of YSZ films by X-ray diffraction, focused ion beam and scanning electron microscopy. The deposited material grows with different morphologies such as columns or grains depending on the substrate used. We observed growth of grains only on the polycrystalline substrates, while on the single crystal columnar crystallites were seen. The YSZ coatings were porous, and nanochannels throughout film layers were observed in all YSZ deposits. Regardless of the type of substrate, all films exhibit a cubic phase of YSZ with the (1 1 1) crystallographic planes parallel to the surface as the major peak

  8. Absolute-frequency measurements with a stabilized near-infrared optical frequency comb from a Cr:forsterite laser

    Science.gov (United States)

    Corwin, K. L.; Thomann, I.; Dennis, T.; Fox, R. W.; Swann, W.; Curtis, E. A.; Oates, C. W.; Wilpers, G.; Bartels, A.; Gilbert, S. L.; Hollberg, L.; Newbury, N. R.; Diddams, S. A.; Nicholson, J. W.; Yan, M. F.

    2004-02-01

    A frequency comb is generated with a chromium-doped forsterite femtosecond laser, spectrally broadened in a dispersion-shifted highly nonlinear fiber, and stabilized. The resultant evenly spaced comb of frequencies ranges from 1.1 to beyond 1.8 μm. The frequency comb was referenced simultaneously to the National Institute of Standards and Technology's optical frequency standard based on neutral calcium and to a hydrogen maser that is calibrated by a cesium atomic fountain clock. With this comb we measured two frequency references in the telecommunications band: one half of the frequency of the d/f crossover transition in 87Rb at 780 nm, and the methane ν2 + 2ν3 R(8) line at 1315 nm.

  9. Thermal stability and spectroscopic properties of erbium-doped niobic-tungsten-tellurite glasses for laser and amplifier devices

    Energy Technology Data Exchange (ETDEWEB)

    Boetti, Nadia G., E-mail: nadia.boetti@polito.it [PhotonLab, Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Lousteau, Joris [PhotonLab, Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Chiasera, Alessandro; Ferrari, Maurizio [CNR-IFN, Istituto di Fotonica e Nanotecnologie, CSMFO Lab. via alla Cascata 56/C, Povo, 38123 Trento (Italy); Mura, Emanuele; Scarpignato, Gerardo C. [PhotonLab, Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Abrate, Silvio [PhotonLab, Istituto Superiore Mario Boella, Via P.C. Boggio, 61, 10138 Torino (Italy); Milanese, Daniel [PhotonLab, Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)

    2012-05-15

    Er{sup 3+} doped niobic-tungsten-tellurite glasses doped with concentration of Er{sup 3+} ion up to 3 wt% were fabricated. The effect of Er{sup 3+} doping concentration on thermal stability and optical properties was investigated in order to obtain the most suitable rare earth content for developing 1.5 {mu}m compact fiber amplifier pumped with a commercial telecom 980 nm laser diode. The maximum doping concentration allowed was found to be around 1.77 Multiplication-Sign 10{sup 20} ions/cm{sup 3}, for which a broad 1.5 {mu}m emission spectra of 65 nm FWHM and a lifetime of 3.4 ms for the {sup 4}I{sub 13/2} level was measured. - Highlights: Black-Right-Pointing-Pointer Thermal and optical properties of Er{sup 3+} doped niobic-tungsten-tellurite glasses. Black-Right-Pointing-Pointer Spectroscopic properties measured when pumped by commercial telecom 980 nm LD. Black-Right-Pointing-Pointer Investigation of the effect of Er{sup 3+}doping level on glass properties. Black-Right-Pointing-Pointer Present glass is a good candidate for efficient 1.5 {mu}m compact fiber amplifier or laser.

  10. Lasers.

    Science.gov (United States)

    Passeron, T

    2012-12-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  11. [Lasers].

    Science.gov (United States)

    Passeron, T

    2012-11-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. Frequency stabilization of a 2.05 μm laser using hollow-core fiber CO2 frequency reference cell

    Science.gov (United States)

    Meras, Patrick; Poberezhskiy, Ilya Y.; Chang, Daniel H.; Spiers, Gary D.

    2010-04-01

    We have designed and built a hollow-core fiber frequency reference cell, filled it with CO2, and used it to demonstrate frequency stabilization of a 2.05 μm Tm:Ho:YLF laser using frequency modulation (FM) spectroscopy technique. The frequency reference cell is housed in a compact and robust hermetic package that contains a several meter long hollow-core photonic crystal fiber optically coupled to index-guiding fibers with a fusion splice on one end and a mechanical splice on the other end. The package has connectorized fiber pigtails and a valve used to evacuate, refill it, or adjust the gas pressure. We have demonstrated laser frequency standard deviation decreasing from >450MHz (free-running) to laser wavelength is of particular interest for spectroscopic instruments due to the presence of many CO2 and H20 absorption lines in its vicinity. To our knowledge, this is the first reported demonstration of laser frequency stabilization at this wavelength using a hollow-core fiber reference cell. This approach enables all-fiber implementation of the optical portion of laser frequency stabilization system, thus making it dramatically more lightweight, compact, and robust than the traditional free-space version that utilizes glass or metal gas cells. It can also provide much longer interaction length of light with gas and does not require any alignment. The demonstrated frequency reference cell is particularly attractive for use in aircraft and space coherent lidar instruments for measuring atmospheric CO2 profile.

  13. A Preliminary In Vitro Study on the Efficacy of High-Power Photodynamic Therapy (HLLT): Comparison between Pulsed Diode Lasers and Superpulsed Diode Lasers and Impact of Hydrogen Peroxide with Controlled Stabilization.

    Science.gov (United States)

    Caccianiga, Gianluigi; Baldoni, Marco; Ghisalberti, Carlo Angelo; Paiusco, Alessio

    2016-01-01

    Aim. In periodontology lasers have been suggested for the photodynamic therapy (PDT): such therapy can be defined as the inactivation of cells, microorganisms, or molecules induced by light and not by heat. The aim of this study was to evaluate results of PDT using a 980 nm diode laser (Wiser Doctor Smile, Lambda SPA, Italy) combined with hydrogen peroxide, comparing a pulsed diode laser (LI) activity to a high-frequency superpulsed diode laser (LII). Materials and Methods. Primary fibroblasts and keratinocytes cell lines, isolated from human dermis, were irradiated every 48 h for 10 days using LI and LII combined with SiOxyL(+) ™ Solution (hydrogen peroxide (HP) stabilized with a glycerol phosphate complex). Two days after the last irradiation, the treated cultures were analyzed by flow cytofluorometry (FACS) and western blotting to quantify keratin 5 and keratin 8 with monoclonal antibodies reactive to cytokeratin 5 and cytokeratin 8. Antimicrobial activity was also evaluated. Results. Both experimental models show the superiority of LII against LI. In parallel, stabilized HP provided better results in the regeneration test in respect to common HP, while the biocidal activity remains comparable. Conclusion. The use of high-frequency lasers combined with stabilized hydrogen peroxide can provide optimal results for a substantial decrease of bacterial count combined with a maximal biostimulation induction of soft tissues and osteogenesis.

  14. Thermal stability of a laser-clad NiCrBSi coating hardened by frictional finishing

    Science.gov (United States)

    Makarov, A. V.; Soboleva, N. N.; Malygina, I. Yu.

    2017-12-01

    Frictional treatment decreases surface roughness of a NiCrBSi laser coating and increases its microhardness and abrasive wear resistance. Even after softening annealing at 900 °C, the coating subjected to frictional treatment preserves its advantage in hardness and wear resistance over the original clad coating. Annealing at 1000 °C after frictional treatment ensures less effective growth of the hardness and wear resistance of the coating as compared to annealing of the undeformed coating due to the limited precipitation of large Cr23C6 carbides on the deformed surface, which form a wear-resistant framework.

  15. Centroid stabilization for laser alignment to corner cubes: designing a matched filter

    Energy Technology Data Exchange (ETDEWEB)

    Awwal, Abdul A. S.; Bliss, Erlan; Brunton, Gordon; Kamm, Victoria Miller; Leach, Richard R.; Lowe-Webb, Roger; Roberts, Randy; Wilhelmsen, Karl

    2016-11-08

    Automation of image-based alignment of National Ignition Facility high energy laser beams is providing the capability of executing multiple target shots per day. One important alignment is beam centration through the second and third harmonic generating crystals in the final optics assembly (FOA), which employs two retroreflecting corner cubes as centering references for each beam. Beam-to-beam variations and systematic beam changes over time in the FOA corner cube images can lead to a reduction in accuracy as well as increased convergence durations for the template-based position detector. A systematic approach is described that maintains FOA corner cube templates and guarantees stable position estimation.

  16. Repetition rate stabilization of an erbium-doped all-fiber laser via opto-mechanical control of the intracavity group velocity

    International Nuclear Information System (INIS)

    Shen, Xuling; He, Boqu; Zhao, Jian; Liu, Yang; Bai, Dongbi; Wang, Chao; Liu, Geping; Luo, Daping; Liu, Fengjiang; Li, Wenxue; Zeng, Heping; Yang, Kangwen; Hao, Qiang

    2015-01-01

    We present a method for stabilizing the repetition rate of an erbium-doped all-fiber laser by inserting an electronic polarization controller (EPC) in the fiber laser cavity. The device exhibited good integration, low cost, and convenient operation. Such a repetition rate stabilization may facilitate an all-fiber laser comb system with high integration. The repetition rate was phase-locked to a Rb reference more than 72 h with a low feedback voltage applied to one channel of the EPC. The repetition rate was 74.6 MHz. The standard deviation and the repetition rate linewidth were 1.4 and 1.7 mHz, respectively

  17. Ultralow-jitter passive timing stabilization of a mode-locked Er-doped fiber laser by injection of an optical pulse train.

    Science.gov (United States)

    Yoshitomi, Dai; Kobayashi, Yohei; Kakehata, Masayuki; Takada, Hideyuki; Torizuka, Kenji; Onuma, Taketo; Yokoi, Hideki; Sekiguchi, Takuro; Nakamura, Shinki

    2006-11-15

    The pulse timing of a mode-locked Er-doped fiber laser was stabilized to a reference pulse train from a Cr:forsterite mode-locked laser by all-optical passive synchronization scheme. The reference pulses were injected into a ring cavity of the fiber laser by using a 1.3-1.5 mum wavelength-division multiplexer. The spectral shift induced by cross-phase modulation between copropagating two-color pulses realizes self-synchronization due to intracavity group-delay dispersion. The rms integration of timing jitter between the fiber laser pulse and the reference pulse was 3.7 fs in a Fourier frequency range from 1 Hz to 100 kHz.

  18. High Power Amplifiers Chain nonlinearity influence on the accelerating beam stability in free electron laser (FLASH)

    CERN Document Server

    Cichalewski, w

    2010-01-01

    The high power amplifiers transfer characteristics nonlinearities can have a negative influence on the overall system performance. This is also true for the TESLA superconducting cavities accelerating field parameters control systems. This Low Level Radio Frequency control systems uses microwave high power amplifiers (like 10 MW klystrons) as actuators in the mentioned feedback loops. The amplitude compression and phase deviations phenomena introduced to the control signals can reduce the feedback performance and cause electron beam energy instabilities. The transfer characteristics deviations in the Free Electron Laser in Hamburg experiment have been investigated. The outcome of this study together with the description of the developed linearization method based on the digital predistortion approach have been described in this paper. Additionally, the results from the linearization tool performance tests in the FLASH's RF systems have been placed.

  19. Low frequency noise fiber delay stabilized laser with reduced sensitivity to acceleration

    Science.gov (United States)

    Argence, B.; Clivati, C.; Dournaux, J.-L.; Holleville, D.; Faure, B.; Lemonde, P.; Santarelli, G.

    2017-11-01

    Lasers with sub-hertz line-width and fractional frequency instability around 1×10-15 for 0.1 s to 10 s averaging time are currently realized by locking onto an ultra-stable Fabry-Perot cavity using the Pound-Drever-Hall method. This powerful method requires tight alignment of free space optical components, precise polarization adjustment and spatial mode matching. To circumvent these issues, we use an all-fiber Michelson interferometer with a long fiber spool as a frequency reference and a heterodyne detection technique with a fibered acousto optical modulator (AOM)1. At low Fourier frequencies, the frequency noise of our system is mainly limited by mechanical vibrations, an issue that has already been explored in the field of optoelectronic oscillators.2,3,4

  20. Process stabilization by dual focus laser welding of aluminum alloys for car body

    Science.gov (United States)

    Shibata, Kimihiro; Iwase, Takakuni; Sakamoto, Hiroki; Dausinger, Friedrich H.; Hohenberger, Bernd; Mueller, Matthias; Matsunawa, Akira; Seto, Naoki

    2003-09-01

    Aluminum alloys were welded using dual focus beams formed with two Nd:YAG lasers with the aim of obtaining a stable welding process. The relationship between the configuration of the spot beams and the quality of the weld beads was investigated using X-ray and high-speed camera observations. The number of pores was clearly related to the ratio of the keyhole depth to the keyhole opening. A larger keyhole opening and/or a shallower keyhole depth resulted in a smaller number of pores caused by instability of the weld pool. Based on the investigation, a car body component was welded with a dual focus beam system. The results show that aluminum car body panels can be welded stably at high speed with little distortion under optimum conditions.

  1. Optoelectronic study and annealing stability of room temperature pulsed laser ablated ZnSe polycrystalline thin films

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Taj Muhammad, E-mail: tajakashne@gmail.com; Zakria, M.; Ahmad, Mushtaq; Shakoor, Rana I.

    2014-03-15

    In principal, we described stability of the room temperature ZnSe thin films with thermal annealing deposited onto glass by pulsed laser deposition technique using third harmonic 355 nm of Nd: YAG laser beam. Optoelectronic analysis and stability with thermal annealing was described in terms of structural and optical properties. These properties were investigated via X-ray diffraction, atomic force microscope, scanning electron microscope, Raman, Fourier transform infrared and photoluminescence spectroscopies. From the strong reflection corresponding to the (1 1 1) plane (2θ=27.48°) and the longitudinal optical “LO” phonon modes at 250 cm{sup −1} and 500 cm{sup −1} in the X-ray diffraction and Raman spectra, a polycrystalline zincblende structure of the film was established. At 300 and 350 °C annealing temperatures, the film crystallites were preferentially oriented with the (1 1 1) plane parallel to the substrate and became amorphous at 400 °C. Atomic force microscopic images showed that the morphologies of ZnSe films became smooth with root mean squared roughness 9.86 nm after annealing at 300 and 350 °C while a rougher surface was observed for the amorphous film at 400 °C. Fourier transform infrared study illustrated the chemical nature and Zn–Se bonding in the deposited films. For the as-deposited and annealed samples at 300 and 350 °C, scanning electron micrographs revealed mono-dispersed indistinguishable ZnSe grains and smooth morphological structure which changed to a cracking and bumpy surface after annealing at 400 °C. The physical phenomenon of annealing induced morphological changes could be explained in terms of “structure zone model”. Excitonic emission at 456 nm was observed for both as-deposited and annealed film at 350 °C. The transmission spectrum shows oscillatory behavior because of the thin film interference and exhibited a high degree of transparency down to a wavelength ∼500 nm in the IR region. Energy band-gap was

  2. A single-longitudinal-mode Brillouin fiber laser passively stabilized at the pump resonance frequency with a dynamic population inversion grating

    International Nuclear Information System (INIS)

    Spirin, V V; López-Mercado, C A; Kinet, D; Mégret, P; Fotiadi, A A; Zolotovskiy, I O

    2013-01-01

    We demonstrate a single-longitudinal-mode Brillouin ring fiber laser passively stabilized at the resonance frequency with a 1.7 m section that is an unpumped polarization-maintaining erbium-doped fiber. The two coupled all-fiber Fabry–Perot interferometers that comprise the cavity, in combination with the dynamical population inversion gratings self-induced in the active fiber, provide adaptive pump-mode selection and Stokes wave generation at the same time. The laser is shown to emit a single-frequency Stokes wave with a linewidth narrower than 100 Hz. (letter)

  3. LASER EMISSIONS FROM CO2 VIBRATIONAL TRANSITIONS IN A LOW TEMPERATURE SUPERSONIC FLOW EXCITED BY A PULSED ELECTRON BEAM STABILIZED DISCHARGE

    OpenAIRE

    Fontaine, B.; Forestier, B.; Gross, P.; Koudriavtsev, E.

    1980-01-01

    High power long pulse infrared laser emission has been achieved on CO2 molecule with the high density and very low temperature supersonic flow-electron beam-stabilized discharge excitation device developped at I.M.F.M. ([MATH] [MATH] 2 amagats, T [MATH] 70 - 150 K). Laser emission at [MATH] = 10.6 µ has been achieved for a resonant cavity set at the discharge location and also 3 cm downstream of the discharge location. With Ar/CO2, Ar/CO2/H2, He/CO2, and He/CO2/N2 mixtures, lasing energy and ...

  4. Structure of a swirl-stabilized spray flame by imaging, laser Doppler velocimetry, and phase Doppler anemometry

    Science.gov (United States)

    Edwards, C. F.; Rudoff, R. C.

    1991-01-01

    Data are presented which describe the mean structure of a steady, swirl-stabilized, kerosene spray flame in the near-injector region of a research furnace. The data presented include ensemble-averaged results of schlieren, luminosity, and extinction imaging, measurement of the gas phase velocity field by laser Doppler velocimetry, and characterization of the condensed phase velocity by phase Doppler anemometry. The results of these studies define six key regions in the flame: the dense spray region; the rich, two-phase, fuel jet; the main air jet; the internal product recirculation zone; the external product recirculation zone; and the gaseous diffusion flame zone. The first five of these regions form a conical mixing layer which prepares the air and fuel for combustion. The air and fuel jets comprise the central portion of this mixing layer and are bounded on either side by the hot product gases of the internal and external recirculation zones. Entrainment of these product gases into the air/fuel streams provides the energy required to evaporate the fuel spray and initiate combustion. Intermittency of the internal recirculation and spray jet flows accounts for unexpected behavior observed in the aerodynamics of the two phases. The data reported herein are part of the database being accumulated on this spray flame for the purpose of detailed comparison with numerical modeling.

  5. Laser frequency stabilization and stray light issues for LISA and other future multi-spacecraft missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — "The Laser Interferometer Space Antenna (LISA) is a joint NASA/ESA project which will use laser interferometry between drag-free proof masses to measure...

  6. Intensity-Stabilized Fast-Scanned Direct Absorption Spectroscopy Instrumentation Based on a Distributed Feedback Laser with Detection Sensitivity down to 4 × 10−6

    Directory of Open Access Journals (Sweden)

    Gang Zhao

    2016-09-01

    Full Text Available A novel, intensity-stabilized, fast-scanned, direct absorption spectroscopy (IS-FS-DAS instrumentation, based on a distributed feedback (DFB diode laser, is developed. A fiber-coupled polarization rotator and a fiber-coupled polarizer are used to stabilize the intensity of the laser, which significantly reduces its relative intensity noise (RIN. The influence of white noise is reduced by fast scanning over the spectral feature (at 1 kHz, followed by averaging. By combining these two noise-reducing techniques, it is demonstrated that direct absorption spectroscopy (DAS can be swiftly performed down to a limit of detection (LOD (1σ of 4 × 10−6, which opens up a number of new applications.

  7. High-pulse energy-stabilized passively mode-locked external cavity inverse bow-tie 980nm laser diode for space applications

    Science.gov (United States)

    Krakowski, M.; Resneau, P.; Garcia, M.; Vinet, E.; Robert, Y.; Lecomte, M.; Parillaud, O.; Gerard, B.; Kundermann, S.; Torcheboeuf, N.; Boiko, D. L.

    2018-02-01

    We report on multi-section inverse bow-tie laser producing mode-locked pulses of 90 pJ energy and 6.5 ps width (895 fs after compression) at 1.3 GHz pulse repetition frequency (PRF) and consuming 2.9 W of electric power. The laser operates in an 80 mm long external cavity. By translation of the output coupling mirror, the PRF was continuously tuned over 37 MHz range without additional adjustments. Active stabilization with a phase lock loop actuating on the driving current has allowed us to reach the PRF relative stability at a 2·10-10 level on 10 s intervals, as required by the European Space Agency (ESA) for inter-satellite long distance measurements.

  8. Adaptive shaping system for both spatial and temporal profiles of a highly stabilized UV laser light source for a photocathode RF gun

    Science.gov (United States)

    Tomizawa, H.; Dewa, H.; Taniuchi, T.; Mizuno, A.; Asaka, T.; Yanagida, K.; Suzuki, S.; Kobayashi, T.; Hanaki, H.; Matsui, F.

    2006-02-01

    We have been developing a stable and highly qualified ultraviolet (UV) laser pulse as a light source of an RF gun for an injector candidate of future light sources. Our gun cavity is a single-cell pillbox, and the copper inner wall is used as a photocathode. The chirped pulse amplification (CPA) Ti:sapphire laser system is operated at a repetition rate of 10 Hz. At the third harmonic generation (central wavelength—263 nm), the laser pulse energy after a 45 cm silica rod is up to 850 μJ/pulse. In its present status, the laser's pulse energy stability has been improved down to 0.2˜0.3% at the fundamental, and 0.7-1.4% (rms; 10 pps; 33,818 shots) at the third harmonic generation, respectively. This stability has been held for 1 month continuously, 24 h a day. The improvements we had passively implemented were to stabilize the laser system as well as the environmental conditions. We introduced a humidity-control system kept at 50-60% in a clean room to reduce damage to the optics. In addition, we prepared a deformable mirror for spatial shaping and a spatial light modulator based on fused-silica plates for temporal shaping. We are applying both the adaptive optics to automatic optimization of the electron beam bunch to produce lower emittance with the feedback routine. Before the improvements, the electron beam produced from a cathode suffered inhomogeneous distribution caused by the quantum efficiency effect, and some pulse distortions caused by its response time. However, we can now freely form any arbitrary electron beam distribution on the surface of the cathode.

  9. Performance tests of the 5 TW, 1 kHz, passively CEP-stabilized ELI-ALPS SYLOS few-cycle laser system (Conference Presentation)

    Science.gov (United States)

    Stanislauskas, Tomas; Budriūnas, Rimantas; Veitas, Gediminas; Gadonas, Darius; Adamonis, Jonas; Aleknavičius, Aidas; Masian, Gžegož; Kuprionis, Zenonas; Hoff, Dominik; Paulus, Gerhard G.; Börzsönyi, Ádám.; Toth, Szabolcs; Kovacs, Mate; Csontos, János; López-Martens, Rodrigo; Osvay, Károly

    2017-05-01

    ELI-ALPS in Hungary, one of the three pillars of the Extreme Light Infrastructure, aims at providing diverse light sources, including energetic attosecond pulses at the highest possible repetition rates. One of the main laser systems for driving plasma and gas-based HHG stages, is a state-of-the-art 1 kHz few-cycle laser called SYLOS. Targeted pulse parameters are an energy of 100 mJ and a duration shorter than two optical cycles (stability as well as high spatiotemporal quality. The first phase of the laser system has already set a new standard in kHz laser system engineering and technology. The performance and reliability of the SYLOS laser have been consistently tested over the course of a six-month trial period. During this time the system was running at least 8 hours a day at full power for more than 5 months. The current output parameters are 5 TW peak power, 45 mJ pulse energy with 9 fs duration and 300 mrad CEP stability, while the spectrum spans over 300 nm around 840 nm central wavelength. The layout follows the general scheme NOPCPA architecture with a passively CEP-stabilized front-end. The pulses are negatively chirped for the amplification process and compressed by a combination of large aperture bulk glass blocks and positively chirped mirrors under vacuum conditions at the output. During the trial period, the laser system demonstrated outstanding reliability. Daily startup and shutdown procedures take only a few minutes, and the command-control system enables pulse parameters to be modified instantly. Controlling the delays of individual NOPCPA stages makes it possible to tailor the output spectrum of the pulses and tune the central wavelength between 770 nm and 940 nm. We performed several experimental tests to find out the pulse characteristics. Pulse duration was verified with Wizzler, chirp-scan, autocorrelation methods and a stereo-ATI independently. All of them confirmed the sub-9 fs pulse duration. We recorded the long-term waveform and

  10. Mutation breeding of Bacillus subtilis YTB4 with high yield of ...

    African Journals Online (AJOL)

    DR TONUKARI NYEROVWO

    2012-07-17

    Jul 17, 2012 ... Helium-neon (He-Ne) laser irradiation is a highly efficient mutation breeding technology and is widely applied to various fields of biological science. Using Bacillus subtilis YTB4 with high yield of multienzyme complex as original strain, mutation breeding was carried out by He-Ne laser irradiation in.

  11. Mutation breeding of Bacillus subtilis YTB4 with high yield of ...

    African Journals Online (AJOL)

    Helium-neon (He-Ne) laser irradiation is a highly efficient mutation breeding technology and is widely applied to various fields of biological science. Using Bacillus subtilis YTB4 with high yield of multienzyme complex as original strain, mutation breeding was carried out by He-Ne laser irradiation in this study. Based on the ...

  12. Fundamental transverse mode selection and self-stabilization in large optical cavity diode lasers under high injection current densities

    Science.gov (United States)

    Avrutin, Eugene A.; Ryvkin, Boris S.; Payusov, Alexey S.; Serin, Artem A.; Gordeev, Nikita Yu

    2015-11-01

    It is shown that in high-power, large optical cavity laser diodes at high injection currents, the optical losses due to nonuniform carrier accumulation in the optical confinement layer can ensure the laser operation in the fundamental transverse mode. An experimental demonstration of switching from second order mode to fundamental mode in large optical cavity lasers with current and/or temperature increase is reported and explained, with the calculated values for the switching current and temperature in good agreement with the measurements. The results experimentally prove the nonuniform nature of carrier accumulation in the confinement layer and may aid laser design for optimizing the output.

  13. Fabrication and stability of fiber bragg gratings for WDM applications using a 266 nm cw-laser

    DEFF Research Database (Denmark)

    Deyerl, Hans-Jürgen; Sørensen, Henrik Rokkjær; Jensen, Jesper Bo Damm

    2003-01-01

    Diode pumped continuous wave all solid state UV-lasers operating at 266 nm offer an interesting alternative to frequency doubled argon ion lasers. We compare photosensitivity, UV-writing of Bragg gratings and thermal decay at 244, 257 and 266 nm....

  14. Relation between size-distribution of Si nanoparticles and oscillation-stabilization time of the mixed region produced during laser ablation

    International Nuclear Information System (INIS)

    Wang Yinglong; Li Yanli; Fu Guangsheng

    2006-01-01

    Assuming Si particles and ambient atoms are elastic hard-spheres, the transportation in ambient gas of Si particles obtained by single-pulsed laser ablation is numerically simulated via Monte Carlo method to investigate the influence of the ambient species and the target-to-substrate distance on the oscillation-stabilization time (OST) of the mixed region. It is found that the ambient gas whose atomic weight is close to that of Si atom can induce the shortest OST; with increasing of the target-to-substrate distance, the OST at first decreases to its minimum, and then begins to increase. Incorporating with some experimental results on size-consistency of Si nanoparticles in pulsed laser ablation, it may be concluded that the shorter the OST of the mixed region, the more uniform the as-formed Si nanoparticles in size

  15. Programming of the Wavelength Stabilization for a Titanium:Sapphire Laser using LabVIEW and Implementation into the CERN ISOLDE RILIS Measurement System

    CERN Document Server

    Rossel, Ralf Erik; Wendt, K; Rothe, S

    In the context of this work the foundation for the commissioning of a comprehensive environmental and operational data acquisition system was established. This development was performed for the Resonance Ionization Laser Ion Source (RILIS) at the ISOLDE radioactive ion beam facility within the European Organization for Nuclear Research CERN. As an essential step towards long-term automated operation, a remote control and wavelength stabilization system for the RILIS titanium:sapphire lasers was put into operation. This required the installation of a data recording infrastructure to work with a distributed sensor network. After operational data within the CERN technical computing network was collected and analyzed, the required wavelength adjustment was automatically performed by a stepper motor-driven correction system. The configuration of the hardware for acquisition and control and the integration of the dedicated system modules was performed using the graphical and data flow oriented programming language ...

  16. Investigation of the Stability of a Two-Span Bridge with the use of a High-Precision Laser Displacement Sensors

    Science.gov (United States)

    Poddaeva, O.; Churin, P.; Fedosova, A.; Truhanov, S.

    2018-03-01

    Studies of aerodynamics of bridge structures are an actual problem. Such attention is paid to the study of wind influence on bridge structures not at all by chance; a large number of cases of loss of stability of such structures are known under the influence of wind up to their complete destruction. The development of non-contact systems of measuring equipment allows solving this problem with a high level of accuracy and reliability. This article presents the results of experimental studies of wind impact on a two-span bridge using specialized measuring system based on high-precision laser displacement sensors.

  17. Room-temperature ferromagnetism in Ca and Mg stabilized cubic zirconia bulk samples and thin films prepared by pulsed laser deposition

    Science.gov (United States)

    Dimri, M. Chandra; Khanduri, H.; Kooskora, H.; Kodu, M.; Jaaniso, R.; Heinmaa, I.; Mere, A.; Krustok, J.; Stern, R.

    2012-11-01

    We report room-temperature ferromagnetism in Ca and Mg stabilized zirconia bulk samples and thin films. Powders were prepared by the citrate-combustion route, and thin films grown on silicon substrates by the pulsed laser deposition technique. X-ray diffractograms and Raman spectra at room temperature reveal the formation of cubic phase zirconia. The observed ferromagnetism is robust at room temperature in both bulk as well as in thin film samples, although it is weaker in thin films. The origin of the ferromagnetism can be related to oxygen vacancies created due to divalent (calcium and magnesium) substitution for tetravalent zirconium ions.

  18. Theoretical Study of an Actively Mode-Locked Fiber Laser Stabilized by an Intracavity Fabry-Perot Etalon: Linear Regime

    Science.gov (United States)

    2007-07-01

    competition without a significant ncrease in the pulse duration. . MATHEMATICAL MODEL FOR THE ASER ur mathematical model of the laser is similar to...to he case 1=0. The increase in the parameter P̂ yields an ncrease in the pulse duration by a factor of approxi- ately 10. It is possible to...etalon and it increases as the finesse of the etalon ncreases . Therefore, in a laser with an etalon, the total ispersion is determined by the parameter D̂

  19. Effect of environmental dust particles on laser textured yttria-stabilized zirconia surface in humid air ambient

    Science.gov (United States)

    Yilbas, B. S.; Ali, H.; Al-Sharafi, A.; Al-Sulaiman, F.; Karatas, C.

    2018-05-01

    Zirconium nitride is used as a selective surface for concentrated solar heating applications and one of the methods to form a zirconium nitride is texturing of zirconia surface by a high intensity laser beam under high pressure nitrogen gas environment. Laser texturing also provides hydrophobic surface characteristics via forming micro/nano pillars at the surface; however, environmental dust settlement on textured surface influences the surface characteristics significantly. In the present study, laser texturing of zirconia surface and effects of the dust particles on the textured surface in a humid air ambient are investigated. Analytical tools are used to assess the morphological changes on the laser textured surface prior and after the dust settlement in the humid air ambient. It is found that laser textured surface has hydrophobic characteristics. The mud formed during condensate of water on the dust particles alters the characteristics of the laser textured surface. The tangential force required to remove the dry mud from the textured surface remains high; in which case, the dried liquid solution at the mud-textured surface interface is responsible for the strong adhesion of the dry mud on the textured surface. The textured surface becomes hydrophilic after the dry mud was removed from the surface by a desalinated water jet.

  20. Low-level laser therapy enhances the stability of orthodontic mini-implants via bone formation related to BMP-2 expression in a rat model.

    Science.gov (United States)

    Omasa, Saori; Motoyoshi, Mitsuru; Arai, Yoshinori; Ejima, Ken-Ichiro; Shimizu, Noriyoshi

    2012-05-01

    The aim of this study was to investigate the stimulatory effects of low-level laser therapy (LLLT) on the stability of mini-implants in rat tibiae. In adolescent patients, loosening is a notable complication of mini-implants used to provide anchorage in orthodontic treatments. Previously, the stimulatory effects of LLLT on bone formation were reported; here, it was examined whether LLLT enhanced the stability of mini-implants via peri-implant bone formation. Seventy-eight titanium mini-implants were placed into both tibiae of 6-week-old male rats. The mini-implants in the right tibia were subjected to LLLT of gallium-aluminium-arsenide laser (830 nm) once a day during 7 days, and the mini-implants in the left tibia served as nonirradiated controls. At 7 and 35 days after implantation, the stability of the mini-implants was investigated using the diagnostic tool (Periotest). New bone volume around the mini-implants was measured on days 3, 5, and 7 by in vivo microfocus CT. The gene expression of bone morphogenetic protein (BMP)-2 in bone around the mini-implants was also analyzed using real-time reverse-transcription polymerase chain reaction assays. The data were statistically analyzed using Student's t test. Periotest values were significantly lower (0.79- to 0.65-fold) and the volume of newly formed bone was significantly higher (1.53-fold) in the LLLT group. LLLT also stimulated significant BMP-2 gene expression in peri-implant bone (1.92-fold). LLLT enhanced the stability of mini-implants placed in rat tibiae and accelerated peri-implant bone formation by increasing the gene expression of BMP-2 in surrounding cells.

  1. Influence of the overlap parameter on the convergence of the ptychographical iterative engine

    International Nuclear Information System (INIS)

    Bunk, Oliver; Dierolf, Martin; Kynde, Soren; Johnson, Ian; Marti, Othmar; Pfeiffer, Franz

    2008-01-01

    The ptychographical iterative engine (PIE) algorithm is examined with both simulated and experimental scanning coherent-diffraction microscopy data. The optimum overlap in terms of image quality, dose on the sample and time of measurements is determined using simulated diffraction data. The validity of the results is supported by experimental helium-neon laser light diffraction data

  2. JPRS Report, China

    Science.gov (United States)

    1991-02-25

    strengthen the procurement the blockade sooner, come to grief by doing so late, and and sales of local products in an attempt to protect the suffer...a multi-purpose electromag- netic valve, a helium neon laser acupuncture instrument, [Article by staff reporters Chen Xiaowei (7115 2556 and a

  3. Maritime Adaptive Optics Beam Control

    Science.gov (United States)

    2010-09-01

    Griot Helium Neon Class II laser with output power of 0.5 mW, operating at a wavelength of 633 nm. The science camera is an IDS uEye-2210SE CCD camera...produced by Edmund Optics, Newport/New Focus, Thor Labs, and CVI Melles Griot . Two computer controllers are used for the full experimental system. The

  4. Apparatus Notes

    Science.gov (United States)

    Eaton, Bruce G., Ed.

    1977-01-01

    Describes a low-cost wave analyzer; how to convert an incandescant light bulb to an x-ray tube; how to use an electric toothbrush to generate waves; the use of a light-emitting diode as a point light source; how to rejuvenate helium-neon lasers; and calibration of an ammeter. (MLH)

  5. and for the detection complexes An evaluation of nephelometry ...

    African Journals Online (AJOL)

    saline and tested for spontaneous light scattering in a helium- neon laser nephelometer (Behring). Light scattei-ing was expressed as volts displayed on a digital meter. Sera, in 0,2 ml volumes, were transferred into cuvettes of low background reading (LN cuvettes, Behring) and measured for turbidity causing scattering.

  6. Simple Ultra-Low-Cost Undergraduate Holography Using a Modified Michelson Interferometer.

    Science.gov (United States)

    Rudmin, J. W.; And Others

    1980-01-01

    A technique is presented for producing holograms using equipment which is already in the possesion of the majority of college physics departments, which includes a slightly modified Michelson interferometer, a helium-neon laser, and a long focal-length lens. Production of high quality holograms has been achieved by inexperienced undergraduates…

  7. Stability of contamination-free gold and silver nanoparticles produced by nanosecond laser ablation of solid targets in water

    Energy Technology Data Exchange (ETDEWEB)

    Nikov, R.G., E-mail: rosen_nikov@abv.bg [Institute of Electronics, Bulgarian Academy of Sciences, Tzarigradsko shousse 72, Sofia 1784 (Bulgaria); Nikolov, A.S.; Nedyalkov, N.N. [Institute of Electronics, Bulgarian Academy of Sciences, Tzarigradsko shousse 72, Sofia 1784 (Bulgaria); Dimitrov, I.G. [Institute of Electronics, Bulgarian Academy of Sciences, Tzarigradsko shousse 72, Sofia 1784 (Bulgaria); Institute of Experimental Pathology and Parasitology, Bulgarian Academy of Sciences, G. Bonchev Street, bl. 25, Sofia 1113 (Bulgaria); Atanasov, P.A. [Institute of Electronics, Bulgarian Academy of Sciences, Tzarigradsko shousse 72, Sofia 1784 (Bulgaria); Alexandrov, M.T. [Institute of Experimental Pathology and Parasitology, Bulgarian Academy of Sciences, G. Bonchev Street, bl. 25, Sofia 1113 (Bulgaria)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Au and Ag colloids were prepared by nanosecond laser ablation of solids in water. Black-Right-Pointing-Pointer The alteration of the produced colloids during one month was investigated. Black-Right-Pointing-Pointer Optical transmission spectra of the samples were measured from 350 to 800 nm. Black-Right-Pointing-Pointer TEM measurements were made of as-prepared colloids and on the 30-th day. Black-Right-Pointing-Pointer Zeta potential measurements were performed of as-prepared samples. - Abstract: Preparation of noble metal nanoparticle (NPs) colloids using pulsed laser ablation in water has an inherent advantage compared to the different chemical methods used, especially when biological applications of the colloids are considered. The fabrication method is simple and the NPs prepared in this way are contamination free. The method of laser ablation of a solid target in water is applied in the present work in order to obtain gold and silver NP colloids. The experiment was preformed by using the fundamental wavelength (1064 nm) of a Nd:YAG laser system. The target immersed in double distilled water was irradiated for 20 min by laser pulses with duration of 15 ns and repetition rate of 10 Hz. The sedimentation and aggregation of NPs in the colloids, stored at constant temperature, as a function of the time after preparation were investigated. The analyses are based on optical transmission spectroscopy in UV and vis regions. The change of the plasmon resonance wavelength as a function of time was studied. Zeta potential measurement was also utilized to measure the charge of the NPs in the colloids. The size distribution of the NPs and its change in time was determined by transmission electron microscopy (TEM). On the basis of the results obtained, the optimal conditions of post fabrication manipulation with gold and silver colloids are defined in view of producing stable NPs with a narrow size distribution.

  8. Flight and Stability of a Laser Inertial Fusion Energy Target in the Drift Region between Injection and the Reaction Chamber with Computational Fluid Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Mitori, T. [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States)

    2013-12-01

    A Laser Inertial Fusion Energy (LIFE) target’s flight through a low Reynolds number and high Mach number regime was analyzed with computational fluid dynamics software. This regime consisted of xenon gas at 1,050 K and approximately 6,670 Pa. Simulations with similar flow conditions were performed with a sphere and compared with experimental data and published correlations for validation purposes. Transient considerations of the developing flow around the target were explored. Simulations of the target at different velocities were used to determine correlations for the drag coefficient and Nusselt number as functions of the Reynolds number. Simulations with different angles of attack were used to determine the aerodynamic coefficients of drag, lift, Magnus moment, and overturning moment as well as target stability. The drag force, lift force, and overturning moment changed minimally with spin. Above an angle of attack of 15°, the overturning moment would be destabilizing. At low angles of attack (less than 15°), the overturning moment would tend to decrease the target’s angle of attack, indicating the lack of a need for spin for stability at small angles. This stabilizing moment would cause the target to move in a mildly damped oscillation about the axis parallel to the free-stream velocity vector through the target’s center of gravity.

  9. Monolithic all-PM femtosecond Yb-fiber laser stabilized with a narrow-band fiber Bragg grating and pulse-compressed in a hollow-core photonic crystal fiber

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Liu, Xiaomin; Lægsgaard, Jesper

    2008-01-01

    We report on an environmentally stable self-starting monolithic (i.e. without any free-space coupling) all-polarization-maintaining (PM) femtosecond Yb-fiber laser, stabilized against Q-switching by a narrow-band fiber Bragg grating and modelocked using a semiconductor saturable absorber mirror....... The laser output is compressed in a spliced-on hollow-core PM photonic crystal fiber, thus providing direct end-of-the-fiber delivery of pulses of around 370 fs duration and 4 nJ energy with high mode quality. Tuning the pump power of the end amplifier of the laser allows for the control of output pulse...

  10. Disturbance of visual functions as a result of temporary blinding from low power lasers

    Science.gov (United States)

    Reidenbach, Hans-Dieter

    2010-04-01

    Although it is well-known that dazzle, flash-blindness and afterimages may be caused by bright optical radiation, only sparse quantitative data are available with regard to the effects arising from low power laser products. Indirect effects like temporary blinding might result in serious incidents or even accidents due to the alteration of visual functions like visual acuity, contrast sensitivity and color discrimination. In order to determine the degree and duration of impairment resulting from dazzle, flash-blindness and afterimages, caused by a laser beam, an investigation has been performed with the goal to improve the current knowledge as far as especially the visual acuity recovery duration is concerned. Two different test set-ups were designed and applied in order to determine the afterimage duration and the recovery time for visual acuity after temporary blinding from a laser, respectively. In order to get the desired information a helium-neon laser was mounted on a movable assembly where the respective beam position and direction could be set up on a semicircle. In addition the mount could be inclined in a vertical plane in order to increase the variability of feasible settings. The power was adjusted in several steps in order to investigate the respective dependence of the afterimage. The investigations were relatively time consuming, since re-adaptation of about half an hour was necessary after every exposure in order not to falsify the results. The trials have been done with several volunteers in the laboratory. After the experimental mapping of the local afterimage duration for the various sites on the retina the foveal afterimage duration taf,fv produced by a red laser beam was determined. The investigations have shown a strong dependence on the angle between the line of sight and the beam direction. Besides a maximum of 300 s the dose relationship taf,fv/s ~ 50.6•ln[(P•texp)/μJ] - 13.4 for laser output powers P between 10 μW and 30 μW with

  11. PHYSICAL PROCESSES IN LASER MEDIA: Mechanism of population inversion in He(Ne,Ar)-NF3 mixtures pumped by a self-sustained discharge

    Science.gov (United States)

    Lomaev, Mikhail I.; Tarasenko, Viktor F.

    1992-02-01

    Studies of spontaneous radiation and lasing, measurements of the electron density and temperature, and also an analysis of the rates of various processes in mixtures of helium, neon, and argon with NF3 (pumped by a self-sustained discharge) were used to show that, under conditions of lasing due to atomic transitions in rare gases, the upper active level is filled by electronic excitation processes and the lasing pulse duration in the afterglow is limited by ion-ion recombination.

  12. Derivative effect of laser cladding on interface stability of YSZ@Ni coating on GH4169 alloy: An experimental and theoretical study

    Science.gov (United States)

    Zheng, Haizhong; Li, Bingtian; Tan, Yong; Li, Guifa; Shu, Xiaoyong; Peng, Ping

    2018-01-01

    Yttria-stabilized zirconia YSZ@Ni core-shell nanoparticles were used to prepare a thermal barrier coating (TBC) on a GH4169 alloy by laser cladding. Microstructural analysis showed that the TBC was composed of two parts: a ceramic and a bonding layer. In places where the ZrO2/Al2O3 eutectic structure was present in the ceramic layer, the Ni atoms diffused into the bonding layer, as confirmed by energy-dispersive X-ray spectroscopy (EDS). The derivative effect of laser cladding results in the original YSZ@Ni core-shell nanoparticles being translated into the Al2O3 crystal, activating the YSZ. The mechanism of ceramic/metal interface cohesion was studied in depth via first-principles and molecular dynamics simulation. The results show that the trend in the diffusion coefficients of Ni, Fe, Al, and Ti is DNi > DFe > DTi > DAl in the melting or solidification process of the material. The enthalpy of formation for Al2O3 is less than that of TiO2, resulting in a thermally grown oxide (TGO) Al2O3 phase transformation. With regard to the electronic structure, the trend in Mulliken population is QO-Ni > QZr-O > QO-Al. Although the bonding is slightly weakened between ZrO2/Al2O3 (QZr-O = 0.158 matrix. Thus, by comparing the connective and diffusive processes, our findings lay the groundwork for detailed and comprehensive studies of the laser cladding process for the production of composite materials.

  13. X-ray comb generation from nuclear-resonance-stabilized x-ray free-electron laser oscillator for fundamental physics and precision metrology

    Directory of Open Access Journals (Sweden)

    B. W. Adams

    2015-03-01

    Full Text Available An x-ray free-electron laser oscillator (XFELO is a next-generation x-ray source, similar to free-electron laser oscillators at VUV and longer wavelengths but using crystals as high-reflectivity x-ray mirrors. Each output pulse from an XFELO is fully coherent with high spectral purity. The temporal coherence length can further be increased drastically, from picoseconds to microseconds or even longer, by phase-locking successive XFELO output pulses, using the narrow nuclear resonance lines of nuclei such as ^{57}Fe as a reference. We show that the phase fluctuation due to the seismic activities is controllable and that due to spontaneous emission is small. The fluctuation of electron-bunch spacing contributes mainly to the envelope fluctuation but not to the phase fluctuation. By counting the number of standing-wave maxima formed by the output of the nuclear-resonance-stabilized (NRS XFELO over an optically known length, the wavelength of the nuclear resonance can be accurately measured, possibly leading to a new length or frequency standard at x-ray wavelengths. A NRS-XFELO will be an ideal source for experimental x-ray quantum optics as well as other fundamental physics. The technique can be refined for other, narrower resonances such as ^{181}Ta or ^{45}Sc.

  14. Gas-Phase Stability of Negatively Charged Organophosphate Metabolites Produced by Electrospray Ionization and Matrix-Assisted Laser Desorption/Ionization

    Science.gov (United States)

    Asakawa, Daiki; Mizuno, Hajime; Toyo'oka, Toshimasa

    2017-12-01

    The formation mechanisms of singly and multiply charged organophosphate metabolites by electrospray ionization (ESI) and their gas phase stabilities were investigated. Metabolites containing multiple phosphate groups, such as adenosine 5'-diphosphate (ADP), adenosine 5'-triphosphate (ATP), and D- myo-inositol-1,4,5-triphosphate (IP3) were observed as doubly deprotonated ions by negative-ion ESI mass spectrometry. Organophosphates with multiple negative charges were found to be unstable and often underwent loss of PO3 -, although singly deprotonated analytes were stable. The presence of fragments due to the loss of PO3 - in the negative-ion ESI mass spectra could result in the misinterpretation of analytical results. In contrast to ESI, matrix-assisted laser desorption ionization (MALDI) produced singly charged organophosphate metabolites with no associated fragmentation, since the singly charged anions are stable. The stability of an organophosphate metabolite in the gas phase strongly depends on its charge state. The fragmentations of multiply charged organophosphates were also investigated in detail through density functional theory calculations. [Figure not available: see fulltext.

  15. Effect of low-level laser irradiation on the rate and short-term stability of rotational tooth movement in dogs.

    Science.gov (United States)

    Salehi, Parisa; Heidari, Somayeh; Tanideh, Nader; Torkan, Sepideh

    2015-05-01

    Low-level laser therapy (LLLT) has many biostimulative effects such as acceleration of mesiodistal orthodontic tooth movement. However, its effects on the extent and short-term stability of rotational tooth movement have not been researched. The purpose of this study was to investigate the effect of low-level laser irradiation during rotational tooth movement on the rate of movement and the amount of relapse in dogs. In this interventional study, fixed orthodontic appliances were used to rotate both mandibular lateral incisors in 8 dogs. Sixteen teeth were divided into 2 groups: the experimental group with LLLT during orthodontic force application, and a control group with orthodontic couple force application only. In the first group, the gallium-aluminum-arsenide diode laser (810 nm, 200 mw, 10 seconds, 2 J/session, 32 J/cm(2)/point) was emitted on 2 points at the buccal side of the roots on days 0, 1, 2, 3, 4, 7, 14, 21, and 28 during 4 weeks of movement, and the amount of relapse was then observed for 3 months. The extent of rotational movement was measured on dental casts, and the statistical analysis was carried out with t tests. There was no significant difference between the LLLT group and the control group on the amount of rotational tooth movement (P = 0.66). The mean percentages of relapse after 1 week, 1 month, and 3 months were 33.02%, 53.44%, and 60.64% in the LLLT group and 54.22%, 68.74%, and 73.92% in the control group, respectively. This demonstrates significant differences between these groups at all studied times (P ≤0.05). This difference was greatest in the first week and then decreased until the end of the third month. The greatest percentage of relapse in both groups was registered in the first week after tooth movement. The total energy dose of the laser used in this study could not accelerate rotational tooth movement, but it did effectively reduce the relapse tendency in teeth rotated by orthodontic movements. Copyright © 2015 American

  16. Radiation-Resistant Photon-Counting Detector Package Providing Sub-ps Stability for Laser Time Transfer in Space

    Science.gov (United States)

    Prochzaka, Ivan; Kodat, Jan; Blazej, Josef; Sun, Xiaoli (Editor)

    2015-01-01

    We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.

  17. Improving the Reliability and Modal Stability of High Power 870 nm AlGaAs CSP Laser Diodes for Applications to Free Space Communication Systems

    Science.gov (United States)

    Connolly, J. C.; Alphonse, G. A.; Carlin, D. B.; Ettenberg, M.

    1991-01-01

    The operating characteristics (power-current, beam divergence, etc.) and reliability assessment of high-power CSP lasers is discussed. The emission wavelength of these lasers was optimized at 860 to 880 nm. The operational characteristics of a new laser, the inverse channel substrate planar (ICSP) laser, grown by metalorganic chemical vapor deposition (MOCVD), is discussed and the reliability assessment of this laser is reported. The highlights of this study include a reduction in the threshold current value for the laser to 15 mA and a degradation rate of less than 2 kW/hr for the lasers operating at 60 mW of peak output power.

  18. Stabilization of sialic acids in N-linked oligosaccharides and gangliosides for analysis by positive ion matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Powell, A K; Harvey, D J

    1996-01-01

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of oligosaccharides and gangliosides normally causes loss of sialic acid, particularly when alpha-cyano-4-hydroxycinnamic acid is used as the matrix. In addition, the potential signal is split because both positive and, to a greater extent, negative ions are formed while signals are frequently complicated as the result of partial alkali-salt formation. In order to stabilize the sialic acid moieties under MALDI conditions and to divert all of the signal into the positive-ion mode, a method involving their conversion into methyl esters has been developed. The method is relatively rapid and produces strong positive-ion signals from N-linked oligosaccharides containing sialic acid and from gangliosides. The latter compounds are stable, even in the presence of alpha-cyano-4-hydroxycinnamic acid. They give abundant molecular (MNa+) ions, but with sufficient residual in-source fragmentation to allow the sequence of the sugar chain to be determined. The sialic acid residue is stable after methylation, irrespective of its linkage to the parent molecule.

  19. Laser frequency stabilization and control of optical cavities with suspended mirrors for the VIRGO interferometric detector of gravitational waves; Stabilisation en frequence du laser et controle de cavites optiques a miroirs suspendus pour le detecteur interferometrique d'ondes gravitationnelles VIRGO

    Energy Technology Data Exchange (ETDEWEB)

    Barsuglia, Matteo [Paris-11 Univ., 91 Orsay (France)

    1999-05-17

    The VIRGO detector is an interferometer with 3 km Fabry-Perot cavities in the arms. It is aimed at the detection of gravitational radiation emitted by astrophysical sources. This thesis comprises two independent parts. The first part is devoted to the laser frequency stabilization. In the second one we present a study of a suspended cavity. We determine the impact of laser frequency fluctuations on the overall VIRGO sensitivity. We study the frequency stabilization of the interferometer considered as an ultra-stable standard and we evaluate the noise pertaining to different signals taken into consideration. A strategy of control is discussed. We then study the VIRGO mode-cleaner prototype, a 30 m suspended triangular cavity, for which we have developed a control in order to keep it locked. Finally, we characterize this cavity in terms of mode spectra, finesse and mechanical transfer functions. (author)

  20. Space laser components reliability

    OpenAIRE

    Riede, Wolfgang; Schroeder, Helmut

    2015-01-01

    Space environment presents unique challenges for operation of optics and optical coatings as part of laser systems. Besides testing components and sub-systems on the component qualification level, the extended testing of complete laser systems like flight modules under acceptance level conditions is an effective way to determine the reliability and long term stability, mitigating the mission risk. Hence, optics as part of high power space laser systems have to be extensively tested in view...

  1. Low-timing-jitter, stretched-pulse passively mode-locked fiber laser with tunable repetition rate and high operation stability

    International Nuclear Information System (INIS)

    Liu, Yuanshan; Zhang, Jian-Guo; Chen, Guofu; Zhao, Wei; Bai, Jing

    2010-01-01

    We design a low-timing-jitter, repetition-rate-tunable, stretched-pulse passively mode-locked fiber laser by using a nonlinear amplifying loop mirror (NALM), a semiconductor saturable absorber mirror (SESAM), and a tunable optical delay line in the laser configuration. Low-timing-jitter optical pulses are stably produced when a SESAM and a 0.16 m dispersion compensation fiber are employed in the laser cavity. By inserting a tunable optical delay line between NALM and SESAM, the variable repetition-rate operation of a self-starting, passively mode-locked fiber laser is successfully demonstrated over a range from 49.65 to 50.47 MHz. The experimental results show that the newly designed fiber laser can maintain the mode locking at the pumping power of 160 mW to stably generate periodic optical pulses with width less than 170 fs and timing jitter lower than 75 fs in the 1.55 µm wavelength region, when the fundamental repetition rate of the laser is continuously tuned between 49.65 and 50.47 MHz. Moreover, this fiber laser has a feature of turn-key operation with high repeatability of its fundamental repetition rate in practice

  2. Coupled optical resonance laser locking

    CSIR Research Space (South Africa)

    Burd, CC

    2014-10-01

    Full Text Available We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different...

  3. Assessment of the influence of Laser phototherapy on the bone repair process of complete fractures in tibiae of rabbits stabilized with semi-rigid internal fixation treated with or without MTA graft: a histological study

    Science.gov (United States)

    Soares, Luiz G. P.; Silva, Aline C. P.; Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Santos, Nicole R. S.; dos Santos, Jean N.; Pinheiro, Antonio L. B.

    2016-03-01

    Beside biomaterials, Laser phototherapy has shown positive effects as auxiliary therapy in bone repair process, especially when involving large bone losses. The aim of this histological study was to evaluate, by light microscopy, the influence of laser phototherapy on the repair of complete tibial fractures in rabbits treated or not with semi-rigid internal fixation and Mineral Trioxide Aggregate - MTA graft. Twelve Rabbits were randomly divided into four groups with three animals each. After general anesthesia, complete fractures were created in one tibia with a carborundum disk. All animals (groups I-IV) had the fracture stabilized with semi-rigid fixation (wire osteosynthesis - WO). Group I was routinely fixed with WO; groups II and IV fracture was filled by blood clot and MTA implant. In Groups III and IV fracture was filled by blood clot and further irradiated with laser (λ780 nm, 70 mW, CW, Φ = 0.04 cm2, 20.4 J/cm2, per session, t = 300s, 142.8 J/cm2 per treatment). The phototherapy protocol was applied immediately after the surgery and repeated each 48 hours during 15 days. Animal death occurred on the 30th postoperative day. After removal of the specimens, the samples were routinely processed, stained with HE and evaluated by light microscopy. Histologically, the group treated with MTA graft and irradiated with laser showed the fracture filled by a more organized and mature trabecular bone, when compared with all other groups. From the results of the present study, it may be concluded that the association of Laser phototherapy + MTA graft in fractures treated with WO improved bone repair when compared with fractures treated only with WO.

  4. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  5. Coherent Polariton Laser

    Science.gov (United States)

    Kim, Seonghoon; Zhang, Bo; Wang, Zhaorong; Fischer, Julian; Brodbeck, Sebastian; Kamp, Martin; Schneider, Christian; Höfling, Sven; Deng, Hui

    2016-01-01

    The semiconductor polariton laser promises a new source of coherent light, which, compared to conventional semiconductor photon lasers, has input-energy threshold orders of magnitude lower. However, intensity stability, a defining feature of a coherent state, has remained poor. Intensity noise many times the shot noise of a coherent state has persisted, attributed to multiple mechanisms that are difficult to separate in conventional polariton systems. The large intensity noise, in turn, limits the phase coherence. Thus, the capability of the polariton laser as a source of coherence light is limited. Here, we demonstrate a polariton laser with shot-noise-limited intensity stability, as expected from a fully coherent state. This stability is achieved by using an optical cavity with high mode selectivity to enforce single-mode lasing, suppress condensate depletion, and establish gain saturation. Moreover, the absence of spurious intensity fluctuations enables the measurement of a transition from exponential to Gaussian decay of the phase coherence of the polariton laser. It suggests large self-interaction energies in the polariton condensate, exceeding the laser bandwidth. Such strong interactions are unique to matter-wave lasers and important for nonlinear polariton devices. The results will guide future development of polariton lasers and nonlinear polariton devices.

  6. Coherent Polariton Laser

    Directory of Open Access Journals (Sweden)

    Seonghoon Kim

    2016-03-01

    Full Text Available The semiconductor polariton laser promises a new source of coherent light, which, compared to conventional semiconductor photon lasers, has input-energy threshold orders of magnitude lower. However, intensity stability, a defining feature of a coherent state, has remained poor. Intensity noise many times the shot noise of a coherent state has persisted, attributed to multiple mechanisms that are difficult to separate in conventional polariton systems. The large intensity noise, in turn, limits the phase coherence. Thus, the capability of the polariton laser as a source of coherence light is limited. Here, we demonstrate a polariton laser with shot-noise-limited intensity stability, as expected from a fully coherent state. This stability is achieved by using an optical cavity with high mode selectivity to enforce single-mode lasing, suppress condensate depletion, and establish gain saturation. Moreover, the absence of spurious intensity fluctuations enables the measurement of a transition from exponential to Gaussian decay of the phase coherence of the polariton laser. It suggests large self-interaction energies in the polariton condensate, exceeding the laser bandwidth. Such strong interactions are unique to matter-wave lasers and important for nonlinear polariton devices. The results will guide future development of polariton lasers and nonlinear polariton devices.

  7. The ring laser gyro

    Science.gov (United States)

    Chow, W. W.; Gea-Banacloche, J.; Pedrotti, L. M.; Sanders, V. E.; Schleich, W.; Scully, M. O.

    1985-01-01

    This paper presents a review of both active and passive ring laser devices. The operating principles of the ring laser are developed and discussed, with special emphasis given to the problems associated with the achievement of greater sensitivity and stability. First-principle treatments of the nature of quantum noise in the ring laser gyro and various methods designed to avoid low-rotation-rate lock-in are presented. Descriptions of state-of-the-art devices and current and proposed applications (including a proposed test of metric theories of gravity using a passive cavity ring laser) are given.

  8. CO2Laser Direct Written MOF-Based Metal-Decorated and Heteroatom-Doped Porous Graphene for Flexible All-Solid-State Microsupercapacitor with Extremely High Cycling Stability.

    Science.gov (United States)

    Basu, Aniruddha; Roy, Kingshuk; Sharma, Neha; Nandi, Shyamapada; Vaidhyanathan, Ramanathan; Rane, Sunit; Rode, Chandrashekhar; Ogale, Satishchandra

    2016-11-23

    Over the past decade, flexible and wearable microelectronic devices and systems have gained significant importance. Because portable power source is an essential need of such wearable devices, currently there is considerable research emphasis on the development of planar interdigitated micro energy -torage devices by employing diverse precursor materials to obtain functional materials (functional carbon, oxides, etc.) with the desirable set of properties. Herein we report for the first time the use of metal organic framework (MOF) and zeolitic imidazolate framework (ZIF-67) for high-wavelength photothermal laser direct writing of metal-decorated, heteroatom-doped, porous few-layer graphene electrodes for microsupercapacitor application. We argue that the specific attributes of MOF as a precursor and the high-wavelength laser writing approach (which creates extremely high localized and transient temperature (>2500 °C) due to strong absorption by lattice vibrations) are together responsible for the peculiar interesting properties of the carbon material thus synthesized, thereby rendering extremely high cycling stability to the corresponding microsupercapacitor device. Our device exhibits near 100% retention after 200 000 cycles as well as stability under 150° bending.

  9. Elemental researches on the critical issue of laser fusion reactor KOYO-F. Formation of aerosols, protection of beam port and flow stability

    International Nuclear Information System (INIS)

    Norimatsu, T.; Oshige, T.; Mima, K.; Shimada, Y.; Furukawa, H.; Kunugi, T.; Nakajima, H.; Kajimura, Y.

    2008-10-01

    Critical issues on laser fusion reactor with a liquid wall are discussed. Formation of aerosols after laser shot was studied experimentally and theoretically. Our simulation results for formation of aerosols agreed with experimental results obtained with electric discharge through a thin lead membrane. Formation of micro particles is discussed basing on experimental results obtained by backside irradiation of a lead membrane. Protection of beam ports of the laser fusion reactor with a liquid first wall is described. A magnetic field generated with a pulse current successfully shielded the tip of beam ports from alpha particles. A continuous protective liquid LiPb flow controlled with cascade scheme was formed as the protective first wall of KOYO-F. (author)

  10. Thermal effects on cavity stability of chromium- and neodymium-doped gadolinium scandium gallium garnet laser under solar-simulator pumping

    Science.gov (United States)

    Kim, Kyong H.; Venable, Demetrius D.; Brown, Lamarr A.; Lee, Ja H.

    1991-01-01

    Results are presented on testing a Cr- and Nd-codoped Gd-Sc-Ga-garnet (Cr:Nd:GSGG) crystal and a Nd:YAG crystal (both of 3.2 mm diam and 76-mm long) for pulsed and CW laser operations using a flashlamp and solar simulator as pumping sources. Results from experiments with the flashlamp show that, at pulse lengths of 0.11, 0.28, and 0.90 ms, the slope efficiency of the Cd:Nd:GSGG crystal was higher than that of the Nd:YAG crystal and increased with pulse width. With the solar simulator, however, the CW laser operation of the Cr:Nd:GSGG crystal was limited to intensities not greater than 1500 solar constants, while the Nd:YAG laser successfully performed for all pump beam intensities available. It was found that the exposure for several minutes of the Cr:Nd:GSGG crystal to pump beam intensity of 3000 solar constants led to its damage by thermal cracking, indicating that a better solar-pumped CW laser performance may be difficult to realize with rod geometry.

  11. Methods of laser spectroscopy

    International Nuclear Information System (INIS)

    Prior, Y.; Ben-Reuven, A.; Rosenbluh, M.

    1986-01-01

    This book presents information on the following topics: the one-atom maser and cavity quantum electrodynamics; Rydberg atoms and radiation; investigation of nonthermal population distributions with femtosecond optical pulses; intra- and intermolecular energy transfer of large molecules in solution after picosecond excitation; new techniques of time-resolved infrared and Raman spectroscopy using ultrashort laser pulses; spectral linewidth of semiconductor lasers; the hydrogen atom in a new light; laser frequency division and stabilization; modified optical Bloch equations for solids; CARS spectroscopy of transient species; off resonant laser induced ring emission; UV laser ionization spectroscopy and ion photochemistry; laser spectroscopy of proton-transfer in microsolvent clusters; recent advances in intramolecular electronic energy transfer; and photoionization and dissociation of the H 2 molecule near the ionization threshold

  12. Single frequency semiconductor lasers

    CERN Document Server

    Fang, Zujie; Chen, Gaoting; Qu, Ronghui

    2017-01-01

    This book systematically introduces the single frequency semiconductor laser, which is widely used in many vital advanced technologies, such as the laser cooling of atoms and atomic clock, high-precision measurements and spectroscopy, coherent optical communications, and advanced optical sensors. It presents both the fundamentals and characteristics of semiconductor lasers, including basic F-P structure and monolithic integrated structures; interprets laser noises and their measurements; and explains mechanisms and technologies relating to the main aspects of single frequency lasers, including external cavity lasers, frequency stabilization technologies, frequency sweeping, optical phase locked loops, and so on. It paints a clear, physical picture of related technologies and reviews new developments in the field as well. It will be a useful reference to graduate students, researchers, and engineers in the field.

  13. The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths.

    Science.gov (United States)

    Karadas, Muhammet; Çağlar, İpek

    2017-07-01

    The aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. The deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S 3 Bond was applied to each group's dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. The data were analyzed using a univariate analysis of variance and Tukey's test (p  0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. The stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. In conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.

  14. Laser Technology.

    Science.gov (United States)

    Gauger, Robert

    1993-01-01

    Describes lasers and indicates that learning about laser technology and creating laser technology activities are among the teacher enhancement processes needed to strengthen technology education. (JOW)

  15. Megawatt Laser Photolysis of Trimethyl(vinyloxy)silane: Formation of Nano-sized Cross-linked Polyoxocarbosilane with Superior Thermal Stability

    Czech Academy of Sciences Publication Activity Database

    Pola, Josef; Tomovska, R.; Bakardjieva, Snejana; Galíková, Anna; Vacek, Karel; Galík, Aftanas

    2003-01-01

    Roč. 328, 1-3 (2003), s. 227-236 ISSN 0022-3093 R&D Projects: GA MŠk OC 523.60 Institutional research plan: CEZ:AV0Z4032918; CEZ:AV0Z4072921 Keywords : polyoxocarbosilane * laser chemical vapour deposition * trimethyl(vinyloxy) silane Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.563, year: 2003

  16. Luminescence process, refractory stabilities, and new novel electronic states: scanning chemical reactions and novel products for laser induced isotope separation. Progress report, December 1, 1975--July 15, 1976

    International Nuclear Information System (INIS)

    Gole, J.L.

    1976-08-01

    The formulation, development, and use of versatile oven systems for high temperature metal vaporization at temperatures in excess of 2000 0 C are discussed. Refinements of an apparatus appropriate for the production and study of small metal aggregates M/sub n/(2 less than or equal to n less than or equal to 6) are discussed at length. Improvements in the argon ion and nitrogen pumped dye laser systems, and necessary additions for effective interfacing of these dye lasers to the aggregates apparatus are described. Internal calibration standards are discussed. Progress on the production of carbon vapor and the reaction of this vapor with metal atoms and metal dimers to form metal carbides is outlined. Metal sulfide chemistry is discussed. Several specific studies of the luminescence process are outlined. Included in these studies are completed work on aluminum oxidation. Studies of germanium and silicon oxidation are outlined, and new investigations of inorganic hydride oxidation are presented. The status of our efforts to form new and novel surfaces via aggregate deposition is outlined. Quantum chemical calculations on small metal aggregates are discussed. The first applications of dynamic laser induced fluorescence to the AlO molecule are presented

  17. NASA Space Laser Technology

    Science.gov (United States)

    Krainak, Michael A.

    2015-01-01

    Over the next two decades, the number of space based laser missions for mapping, spectroscopy, remote sensing and other scientific investigations will increase several fold. The demand for high wall-plug efficiency, low noise, narrow linewidth laser systems to meet different systems requirements that can reliably operate over the life of a mission will be high. The general trends will be for spatial quality very close to the diffraction limit, improved spectral performance, increased wall-plug efficiency and multi-beam processing. Improved spectral performance will include narrower spectral width (very near the transform limit), increased wavelength stability and or tuning (depending on application) and lasers reaching a wider range of wavelengths stretching into the mid-infrared and the near ultraviolet. We are actively developing high efficiency laser transmitter and high-sensitivity laser receiver systems that are suitable for spaceborne applications.

  18. Influence of the dynamic Stark effect on long-term frequency stability of a self-oscillating magnetometer with laser-pumped alkali atoms

    Science.gov (United States)

    Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.

    2017-11-01

    This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.

  19. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  20. Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

    Science.gov (United States)

    Zmuidzinas, J. S. (Inventor)

    1978-01-01

    A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

  1. 5. Laser plasma interaction

    International Nuclear Information System (INIS)

    Labaune, C.; Fuchs, J.; Bandulet, H.

    2002-01-01

    Imprint elimination, smoothing and preheat control are considerable problems in inertial fusion and their possible solution can be achieved by using low-density porous materials as a buffer in target design. The articles gathered in this document present various aspects of the laser-plasma interaction, among which we have noticed: -) numerical algorithmic improvements of the Vlasov solver toward the simulation of the laser-plasma interaction are proposed, -) the dependence of radiation temperatures and X-ray conversion efficiencies of hohlraum on the target structures and laser irradiation conditions are investigated, -) a study of laser interaction with ultra low-density (0,5 - 20 mg/cm 3 ) porous media analyzing backscattered light at incident laser frequency ω 0 and its harmonics 3*ω 0 /2 and 2*ω 0 is presented, -) investigations of laser interaction with solid targets and crater formation are carried out with the objective to determine the ablation loading efficiency, -) a self organization in an intense laser-driven plasma and the measure of the relative degree of order of the states in an open system based on the S-theorem are investigated, and -) the existence and stability of electromagnetic solitons generated in a relativistic interaction of an intense laser light with uniform under-dense cold plasma are studied

  2. High resolution measurement of earthquake impacts on rock slope stability and damage using pre- and post-earthquake terrestrial laser scans

    Science.gov (United States)

    Hutchinson, Lauren; Stead, Doug; Rosser, Nick

    2017-04-01

    Understanding the behaviour of rock slopes in response to earthquake shaking is instrumental in response and relief efforts following large earthquakes as well as to ongoing risk management in earthquake affected areas. Assessment of the effects of seismic shaking on rock slope kinematics requires detailed surveys of the pre- and post-earthquake condition of the slope; however, at present, there is a lack of high resolution monitoring data from pre- and post-earthquake to facilitate characterization of seismically induced slope damage and validate models used to back-analyze rock slope behaviour during and following earthquake shaking. Therefore, there is a need for additional research where pre- and post- earthquake monitoring data is available. This paper presents the results of a direct comparison between terrestrial laser scans (TLS) collected in 2014, the year prior to the 2015 earthquake sequence, with that collected 18 months after the earthquakes and two monsoon cycles. The two datasets were collected using Riegl VZ-1000 and VZ-4000 full waveform laser scanners with high resolution (c. 0.1 m point spacing as a minimum). The scans cover the full landslide affected slope from the toe to the crest. The slope is located in Sindhupalchok District, Central Nepal which experienced some of the highest co-seismic and post-seismic landslide intensities across Nepal due to the proximity to the epicenters (<20 km) of both of the main aftershocks on April 26, 2015 (M 6.7) and May 12, 2015 (M7.3). During the 2015 earthquakes and subsequent 2015 and 2016 monsoons, the slope experienced rockfall and debris flows which are evident in satellite imagery and field photographs. Fracturing of the rock mass associated with the seismic shaking is also evident at scales not accessible through satellite and field observations. The results of change detection between the TLS datasets with an emphasis on quantification of seismically-induced slope damage is presented. Patterns in the

  3. Beam experiments with state selected Ne (3P0, 3P2) metastable atoms

    International Nuclear Information System (INIS)

    Verheijen, M.J.

    1984-01-01

    Metastable rare gas atoms play an important role in all types of plasmas and gas discharges, e.g. in fluorescent lamps and in laser discharges (helium-neon laser or excimer lasers). In this thesis, the metastable states of NeI are studied. First, the theory of excited neon atoms and diatomic molecules is introduced, as well as Penning ionisation. Next, some experimental facilities are described (e.g. the dye laser system). With these instruments, natural lifetime measurements of the 2p fine structure states of NeI are carried out. Results are reported. Finally, total Penning ionisation cross sections are calculated using the optical potential model. (Auth.)

  4. Far infrared submillimeter spectroscopy with an optically pumped laser

    International Nuclear Information System (INIS)

    Bean, B.L.; Perkowitz, S.

    1979-01-01

    The pumped laser theory of operation is discussed along with the availability of submillimeter lines and media. Spectroscopic systems are described including a pump laser, far infrared laser, and system electronics for laser stabilization and FIR detection. Emphasis is placed on system performance and spectroscopic applications

  5. Cable Stability

    CERN Document Server

    Bottura, L

    2014-01-01

    Superconductor stability is at the core of the design of any successful cable and magnet application. This chapter reviews the initial understanding of the stability mechanism, and reviews matters of importance for stability such as the nature and magnitude of the perturbation spectrum and the cooling mechanisms. Various stability strategies are studied, providing criteria that depend on the desired design and operating conditions.

  6. Turbulent Non-Premixed Flames Stabilized on Double-Slit Curved Wall-Jet Burner with Simultaneous OH-Planar Laser-Induced Fluorescence and Particle Image Velocimetry Measurements

    KAUST Repository

    Mansour, Morkous S.

    2015-04-29

    A double-slit curved wall-jet (CWJ) burner utilizing a Coanda effect by supplying fuel and air as annular-inward jets over a curved surface was employed to investigate the stabilization characteristics and structure of propane/air turbulent non-premixed flames with varying global equivalence ratio and Reynolds number. Simultaneous time-resolved measurements of particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) of OH radicals were conducted. The burner showed a potential of stable and non-sooting operation for relatively large fuel loading and overall rich conditions. Mixing characteristics in cold flow were first examined using an acetone fluorescence technique, indicating substantial transport between the fuel and air by exhibiting appreciable premixing conditions. PIV measurements revealed that the flow field consisted of a wall-jet region leading to a recirculation zone through flow separation, an interaction jet region resulting from the collision of annular-inward jets, followed by a merged-jet region. The flames were stabilized in the recirculation zone and, in extreme cases, only a small flame seed remained in the recirculation zone. Together with the collision of the slit jets in the interaction jet region, the velocity gradients in the shear layers at the boundaries of the annular jets generate the turbulence. Turbulent mean and rms velocities were influenced by the presence of the flame, particularly in the recirculation zone. Flames with a high equivalence ratio were found to be more resistant to local extinction and exhibited a more corrugated and folded nature, particularly at high Reynolds numbers. For flames with a low equivalence ratio, local quenching and re-ignition processes maintained flames in the merged jet region, revealing a strong intermittency, which was substantiated by the increased principal strain rates for these flames. © 2015 Taylor & Francis Group, LLC.

  7. All-fiber interferometer-based repetition-rate stabilization of mode-locked lasers to 10-14-level frequency instability and 1-fs-level jitter over 1  s.

    Science.gov (United States)

    Kwon, Dohyeon; Kim, Jungwon

    2017-12-15

    We report on all-fiber Michelson interferometer-based repetition-rate stabilization of femtosecond mode-locked lasers down to 1.3×10 -14 frequency instability and 1.4 fs integrated jitter in a 1 s time scale. The use of a compactly packaged 10 km long single-mode fiber (SMF)-28 fiber link as a timing reference allows the scaling of phase noise at a 10 GHz carrier down to -80  dBc/Hz at 1 Hz Fourier frequency. We also tested a 500 m long low-thermal-sensitivity fiber as a reference and found that, compared to standard SMF-28 fiber, it can mitigate the phase noise divergence by ∼10  dB/dec in the 0.1-1 Hz Fourier frequency range. These results suggest that the use of a longer low-thermal-sensitivity fiber may achieve sub-femtosecond integrated timing jitter with sub-10 -14 -level frequency instability in repetition rate by a simple and robust all-fiber-photonic method.

  8. Delayed Higher-Order Optical Nonlinearities in Noble Gases

    Science.gov (United States)

    Tarazkar, Maryam; Romanov, Dmitri; Levis, Robert

    2014-05-01

    The role of higher-order Kerr effect (HOKE) in femtosecond laser filamentation is currently at the center of a controversy, as alleged crossover from positive to negative nonlinear refractive index at higher intensities was proposed to cause filament stabilization. Experimental evidence of HOKE crossover or lack thereof is being hotly debated. Motivated by this debate, we report the frequency-dependent nonlinear refractive index coefficients n2 and n4 for a series of atmospheric-pressure noble gases: helium, neon, argon, krypton, and xenon. The corresponding atomic hyperpolarizability coefficients are obtained via auxiliary static electric field approach developed on the basis of ab initio calculations implemented in Dalton program and performed at the CCSD level of theory with t-Aug-cc-PV5Z basis set. The n4 index is obtained using the relations between the degenerate six-wave mixing coefficient and some other frequency-dependent second hyperpolarizability coefficients, which can be calculated on the basis of n2via the auxiliary field approach. For all the investigated gases, the n4 indices are found to be positive over the wavelength range 300 nm-1500 nm. This result runs counter to the HOKE crossover hypothesis. The calculated n4 indices demonstrate considerable temporal dispersion, which progressively increases from helium to xenon. This feature implies delayed nonlinearity and calls for modifications in current theoretical models of filamentation process. We gratefully acknowledge financial support through AFOSR MURI Grant No. FA9550-10-1-0561.

  9. The Newest Laser Processing

    International Nuclear Information System (INIS)

    Lee, Baek Yeon

    2007-01-01

    This book mentions laser processing with laser principle, laser history, laser beam property, laser kinds, foundation of laser processing such as laser oscillation, characteristic of laser processing, laser for processing and its characteristic, processing of laser hole including conception of processing of laser hole and each material, and hole processing of metal material, cut of laser, reality of cut, laser welding, laser surface hardening, application case of special processing and safety measurement of laser.

  10. Lasers in clinical ophthalmology

    Science.gov (United States)

    Ribeiro, Paulo A.

    1992-03-01

    The clinical application of lasers in ophthalmology is schematized, showing for each anatomic eye structure, pathologies that may be treated through this procedure. In the cornea, the unusual laser practice for suture removals and the promising possibility of the excimer laser in refractive surgery are discussed. In the iris, the camerular angle, and the ciliary body, the laser application is essentially used to treat the glaucoma and other situations that are not so frequent. The capsulotomy with YAG LASER is used in the treatment of structures related with crystalline and, at least, the treatment of the retina and choroid pathology is expanded. A. A. explained the primordial interest and important of laser in the diabetic retinopathy treatment and some results in patients with more than 5 years of evolution are: 55 of the patients with proliferative diabetic retinopathy (RDP) treated for more than 5 years noticed their vision improved or stabilized; 5 years after treating patients with PDR, 49.3 had their vision stabilized or even improved, provided the diabetics had declared itself more than 20 years ago, versus 61.7 provided the diabetics had declared itself less than 20 years before; finally, 53.8 of the patients under 40-years-old when the diabetics was diagnosed, had their vision improved or at least stabilized 5 years after the beginning of the treatment. On the other side, when patients were over 40 years old when the diabetics was diagnosed percentage increased to 55.9. This study was established in the follow-up of 149 cases over 10 years.

  11. Optical pumping of Rb by Ti:Sa laser and high-power laser diode

    Czech Academy of Sciences Publication Activity Database

    Buchta, Zdeněk; Rychnovský, Jan; Lazar, Josef

    2006-01-01

    Roč. 8, č. 1 (2006), s. 350-354 ISSN 1454-4164 R&D Projects: GA AV ČR IAA1065303; GA ČR GA102/04/2109 Institutional research plan: CEZ:AV0Z20650511 Keywords : optical pumping * Ti:Sa laser * laser diode * emission linewidth * spectroscopy * laser frequency stabilization Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.106, year: 2006

  12. Laser modulator for LISA pathfinder

    Science.gov (United States)

    Voland, C.; Lund, G.; Coppoolse, W.; Crosby, P.; Stadler, M.; Kudielka, K.; Özkan, C.

    2017-11-01

    LISA Pathfinder is an ESA experiment to demonstrate the key technologies needed for the LISA mission to detect gravitational waves in space. The LISA Pathfinder spacecraft represents one arm of the LISA interferometer, containing an optical metrology system and two proof masses as inertial references for the drag-free control system. The LISA Pathfinder payload consists of two drag-free floating test masses located in the inertial sensors with their control electronics and an optical metrology subsystem. The optical metrology subsystem monitors the movement of both test masses relative to each other and to the spacecraft with very high sensitivity and resolution. This is achieved with a heterodyne Mach- Zehnder interferometer. This interferometer requires as input two coherent laser beams with a heterodyne frequency difference of a few kHz. To generate the two laser beams with a heterodyne frequency difference a Nd:YAG laser is used together with the Laser Modulator. The Nd:YAG laser generates a single coherent laser signal at a wavelength of 1064nm which is fibre coupled to the Laser Modulator. The Laser Modulator then generates the two optical beams with the required heterodyne frequency offset. In addition, the Laser Modulator is required to perform laser amplitude stabilization and optical path difference control for the two optical signals. The Laser Modulator consists of an optical unit - the LMU - and RF synthesiser, power amplification and control electronics. These electronics are all housed in the Laser Modulator Electronics (LME). The LMU has four primary functions: • Splitting of the input laser beam into two paths for later superposition in the interferometer. • Applying different frequency shifts to each of the beams. • Providing amplitude modulation control to each of the beams. • Providing active control of the optical path length difference between the two optical paths. The present paper describes the design and performance of the LMU

  13. Intrinsic Dynamics of Quantum-Dash Lasers

    KAUST Repository

    Chen, Cheng

    2011-10-01

    Temperature-dependent intrinsic modulation response of InAs/InAlGaAs quantum-dash lasers was investigated by using pulse optical injection modulation to minimize the effects of parasitics and self-heating. Compared to typical quantum-well lasers, the quantum-dash lasers were found to have comparable differential gain but approximately twice the gain compression factor, probably due to carrier heating by free-carrier absorption, as opposed to stimulated transition. Therefore, the narrower modulation bandwidth of the quantum-dash lasers than that of quantum-well lasers was attributed to their higher gain compression factor. In addition, as expected, quantum-dash lasers with relatively long and uniform dashes exhibit higher temperature stability than quantum-well lasers. However, the lasers with relatively short and nonuniform dashes exhibit stronger temperature dependence, probably due to their higher surface-to-volume ratio and nonuniform dash sizes. © 2011 IEEE.

  14. Development of Cr,Nd:GSGG laser as a pumping source of Ti:sapphire laser

    International Nuclear Information System (INIS)

    Tamura, Koji; Arisawa, Takashi

    1999-08-01

    Since efficiency of Cr,Nd doped gadolinium scandium gallium garnet (GSGG) laser is in principle higher than that of Nd:YAG laser, it can be a highly efficient pumping source for Ti:sapphire laser. We have made GSGG laser, and measured its oscillation properties. It was two times more efficient than Nd:YAG laser at free running mode operation. At Q-switched mode operation, fundamental output of 50 mJ and second harmonics output of 8 mJ were obtained. The developed laser had appropriate spatial profile, temporal duration, long time stability for solid laser pumping. Ti:sapphire laser oscillation was achieved by the second harmonics of GSGG laser. (author)

  15. Laser Therapy

    Science.gov (United States)

    ... for Every Season How to Choose the Best Skin Care Products In This Section Dermatologic Surgery What is dermatologic ... for Every Season How to Choose the Best Skin Care Products Laser Resurfacing Uses for Laser Resurfacing Learn more ...

  16. [On the treatment of gunshot wounds of extremities in the conditions of local military actions].

    Science.gov (United States)

    Agakhanian, N V; Ter-Avetikian, Z A; Mkrtchian, M E; Amirian, E G

    2009-04-01

    Together with the improvement of new types of weapons with more destroying effect, the treatment methods of gunshot wounds including laser therapy, extrafocal osteosynthesis, new antibacterial means are also developing. The application of these methods makes it possible to create optimal conditions for the treatment of different types of injuries of extremities with positive results in 88% cases. These results were received due to early and thorough first surgical processing of wounds by wide usage of helium-neon laser radiation as well as with the help of traumatologists who are the skilled in the new treatment methods including the extrafocal compressional osteosynthesis.

  17. Lasers technology

    International Nuclear Information System (INIS)

    2014-01-01

    The Laser Technology Program of IPEN is developed by the Center for Lasers and Applications (CLA) and is committed to the development of new lasers based on the research of new optical materials and new resonator technologies. Laser applications and research occur within several areas such as Nuclear, Medicine, Dentistry, Industry, Environment and Advanced Research. Additional goals of the Program are human resource development and innovation, in association with Brazilian Universities and commercial partners

  18. Superthin resonator dye laser with THz intermode frequency separation

    International Nuclear Information System (INIS)

    Rudych, P D; Surovtsev, N V

    2014-01-01

    Two-color laser irradiation is considered an effective way to pump THz excitations for numerous scientific and applied goals. We present a design for convenient laser source with THz intermode frequency separation. The setup is based on dye laser with superthin resonator pumped by a subnanosecond pulse laser. It was proven that the superthin resonator dye laser is useful, possesses high stability and high energy conversion, and generates narrow laser modes. The ability of this laser to pump CARS processes for THz vibrations is demonstrated. (letter)

  19. Laser beam riding artillery missiles guidance device is designed

    Science.gov (United States)

    Yan, Mingliang; Huo, Zhicheng; Chen, Wei

    2014-09-01

    Laser driving gun missile guidance type beam of laser information field formed by any link failure or reduced stability will directly lead to ballistic or miss out of control, and based on this, this paper designed the driving beam of laser guided missile guidance beam type forming device modulation and zoom mechanism, in order to make the missile can recognize its position in the laser beam, laser beam gun missile, by means of spatial encoding of the laser beam laser beam into information after forming device, a surface to achieve the purpose of precision guidance.

  20. Laser Dyes

    Indian Academy of Sciences (India)

    treatments, including port-wine stain and tattoo removal, diag- nostic measurements, lithotripsy, activation of photosensitive drugs for photodynamic therapy, etc. In the field of medical applications, dye lasers have potential advantages over other lasers. Dye lasers are unique sources of tunable coherent radiation, from the ...

  1. HF laser

    International Nuclear Information System (INIS)

    Suzuki, Kazuya; Iwasaki, Matae

    1977-01-01

    A review is made of the research and development of HF chemical laser and its related work. Many gaseous compounds are used as laser media successfully; reaction kinetics and technological problems are described. The hybrid chemical laser of HF-CO 2 system and the topics related to the isotope separation are also included. (auth.)

  2. Mirrorless lasers

    Indian Academy of Sciences (India)

    wavelength of operation thereby tuning the laser. Another way of ... of operation. Considering the crucial role of mirrors in a laser, the phrase 'mirrorless lasers' seems to be a paradoxical one. However, in what follows, we will see how one can indeed ..... A possible military application is to have a small area in a person's.

  3. Lasers (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Hal

    1969-01-01

    A laser is an instrument that produces an enormously intense pencil-thin beam of light. In this booklet we shall learn what there is about the laser that gives it so much promise. We shall investigate what it is, how it works, and the different kinds of lasers there are.

  4. Microchip Lasers

    Science.gov (United States)

    2016-10-31

    USA E-mail: zayhowski@ll.mit.edu Abstract Microchip lasers are a rich family of solid-state lasers defined by their small size, robust integration...reliability, and potential for low-cost mass production. Continuous-wave microchip lasers cover a wide range of wavelengths, often operate single

  5. DFB fiber laser as source for optical communication systems

    DEFF Research Database (Denmark)

    Varming, Poul; Hübner, Jörg; Kristensen, Martin

    1997-01-01

    The results demonstrate that DFB fiber lasers are an attractive alternative as sources in telecommunication systems. The lasers show excellent long-term stability with very high signal to noise ratio and a reasonable output power, combined with exceptional temperature stability and inherent fiber...

  6. Performance of the ATLAS Tile LaserII Calibration System

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00124895; The ATLAS collaboration

    2015-01-01

    The new laser calibration system of the ATLAS Tile hadron calorimeter is presented. The perfomances of the calibration and monitor tools internal to the laser system are given in terms of operation time stability. The use of the laser system in the normal Tile calibration procedures is also described.

  7. Laser photocoagulation - eye

    Science.gov (United States)

    Laser coagulation; Laser eye surgery; Photocoagulation; Laser photocoagulation - diabetic eye disease; Laser photocoagulation - diabetic retinopathy; Focal photocoagulation; Scatter (or pan retinal) photocoagulation; Proliferative ...

  8. Synthesis and stabilization of oxide-based colloidal suspensions in organic media: application in the preparation of hybrids organic-inorganic materials for very high laser damage threshold coatings

    International Nuclear Information System (INIS)

    Marchet, N.

    2008-02-01

    Multilayer coatings are widely used in optic and particular in the field of high power laser on the components of laser chains. The development of a highly reflective coating with a laser damage resistance requires the fine-tuning of a multilayer stack constituted by a succession alternated by materials with low and high refractive index. In order to limit the number of layers in the stack, refractive indexes must be optimized. To do it, an original approach consists in synthesizing new organic-inorganic hybrid materials satisfying the criteria of laser damage resistance and optimized refractive index. These hybrid materials are constituted by nano-particles of metal oxides synthesized by sol-gel process and dispersed in an organic polymer with high laser damage threshold. Nevertheless, this composite system requires returning both compatible phases between them by chemical grafting of alc-oxy-silanes or carboxylic acids. We showed that it was so possible to disperse in a homogeneous way these functionalized nano-particles in non-polar, aprotic solvent containing solubilized organic polymers, to obtain time-stable nano-composite solutions. From these organic-inorganic hybrid solutions, thin films with optical quality and high laser damage threshold were obtained. These promising results have permitted to realize highly reflective stacks, constituted by 7 pairs with optical properties in agreement with the theoretical models and high laser damage threshold. (author)

  9. Laser welding and collagen crosslinks

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, K.M.; Last, J.A. [California Univ., Davis, CA (United States). Dept. of Medicine; Small, W. IV; Maitland, D.J.; Heredia, N.J.; Da Silva, L.B.; Matthews, D.L. [Lawrence Livermore National Lab., CA (United States)

    1997-02-20

    Strength and stability of laser-welded tissue may be influenced, in part, by effects of laser exposure on collagen crosslinking. We therefore studied effects of diode laser exposure (805 nm, 1-8 watts, 30 seconds) + indocyanine green dye (ICG) on calf tail tendon collagen crosslinks. Effect of ICG dye alone on crosslink content prior to laser exposure was investigated; unexpectedly, we found that ICG-treated tissue had significantly increased DHLNL and OHP, but not HLNL. Laser exposure after ICG application reduced elevated DHLNL and OHP crosslink content down to their native levels. The monohydroxylated crosslink HLNL was inversely correlated with laser output (p<0.01 by linear regression analysis). DHLNL content was highly correlated with content of its maturational product, OHP, suggesting that precursor-product relations are maintained. We conclude that: (1)ICG alone induces DHLNL and OHP crosslink formation; (2)subsequent laser exposure reduces the ICG-induced crosslinks down to native levels; (3)excessive diode laser exposure destroys normally occurring HLNL crosslinks.

  10. Simple locking of infrared and ultraviolet diode lasers to a visible laser using a LabVIEW proportional-integral-derivative controller on a Fabry-Perot signal.

    Science.gov (United States)

    Kwolek, J M; Wells, J E; Goodman, D S; Smith, W W

    2016-05-01

    Simultaneous laser locking of infrared (IR) and ultraviolet lasers to a visible stabilized reference laser is demonstrated via a Fabry-Perot (FP) cavity. LabVIEW is used to analyze the input, and an internal proportional-integral-derivative algorithm converts the FP signal to an analog locking feedback signal. The locking program stabilized both lasers to a long term stability of better than 9 MHz, with a custom-built IR laser undergoing significant improvement in frequency stabilization. The results of this study demonstrate the viability of a simple, computer-controlled, non-temperature-stabilized FP locking scheme for our applications, laser cooling of Ca(+) ions, and its use in other applications with similar modest frequency stabilization requirements.

  11. The GPS Laser Retroreflector Array Project

    Science.gov (United States)

    Merkowitz, Stephen M.

    2012-01-01

    Systematic co-location in space through the precision orbit determination of GPS satellites via satellite laser ranging will contribute significantly towards improving the accuracy and stability of the international terrestrial reference frame. NASA recently formed the GPS Laser Retroreflector Array Project to develop and deliver retroreflectors for integration on the next generation of GPS satellites. These retroreflectors will be an important contributor to achieving a global accuracy of 1.0 mm and 0.1 mm/year stability in the international terrestrial reference frame. We report here the current status of the GPS Laser Retroreflector Array Project.

  12. Laser generated nanoparticles based photovoltaics.

    Science.gov (United States)

    Petridis, C; Savva, K; Kymakis, E; Stratakis, E

    2017-03-01

    The exploitation of nanoparticles (NP), synthesized via laser ablation in liquids, in photovoltaic devices is reviewed. In particular, the impact of NPs' incorporation into various building blocks within the solar cell architecture on the photovoltaic performance and stability is presented and analysed for the current state of the art photovoltaic technologies. Copyright © 2016. Published by Elsevier Inc.

  13. [Pigmentary lasers].

    Science.gov (United States)

    Passeron, Thierry; Toubel, Gérard

    2009-10-01

    The pigmentary disorders are a very heterogeneous group with a high therapeutic demand from the patients. The lasers have provided a major advance in the treatment of some pigmentary lesions. The indication and the optimal parameters are actually quite well defined. However, pigmentary lasers have limits and some dermatosis can even be worsened after laser treatment. Those limitations as well as the potential side effects have to clearly be explained to the patients that often seek for a miracle cure.

  14. Laser accelerator

    OpenAIRE

    Vigil, Ricardo

    2014-01-01

    Approved for public release; distribution is unlimited In 1979,W. B. Colson and S. K. Ride proposed a new kind of electron accelerator using a uniform magnetic field in combination with a circularly-polarized laser field. A key concept is to couple the oscillating electric field to the electron’s motion so that acceleration is sustained. This dissertation investigates the performance of the proposed laser accelerator using modern high powered lasers and mag-netic fields that are significan...

  15. FIR laser-development program. Final report

    International Nuclear Information System (INIS)

    Danielwicz, E.J.; Hodges, D.T.

    1980-01-01

    The important features for a source intended for use as a local oscillator in a low noise receiver have been tested on a developmental model of a cw FIR laser package. High output power (45 mW), good long term amplitude stability (+- 3%), high spectral purity and excellent frequency stability have all been demonstrated in the laboratory environment

  16. Laser fusion

    International Nuclear Information System (INIS)

    Eliezer, S.

    1982-02-01

    In this paper, the physics of laser fusion is described on an elementary level. The irradiated matter consists of a dense inner core surrounded by a less dense plasma corona. The laser radiation is mainly absorbed in the outer periphery of the plasma. The absorbed energy is transported inward to the ablation surface where plasma flow is created. Due to this plasma flow, a sequence of inward going shock waves and heat waves are created, resulting in the compression and heating of the core to high density and temperature. The interaction physics between laser and matter leading to thermonuclear burn is summarized by the following sequence of events: Laser absorption → Energy transport → Compression → Nuclear Fusion. This scenario is shown in particular for a Nd:laser with a wavelength of 1 μm. The wavelength scaling of the physical processes is also discussed. In addition to the laser-plasma physics, the Nd high power pulsed laser is described. We give a very brief description of the oscillator, the amplifiers, the spatial filters, the isolators and the diagnostics involved. Last, but not least, the concept of reactors for laser fusion and the necessary laser system are discussed. (author)

  17. Biocavity Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Gourley, P.L.; Gourley, M.F.

    2000-10-05

    Laser technology has advanced dramatically and is an integral part of today's healthcare delivery system. Lasers are used in the laboratory analysis of human blood samples and serve as surgical tools that kill, burn or cut tissue. Recent semiconductor microtechnology has reduced the size o f a laser to the size of a biological cell or even a virus particle. By integrating these ultra small lasers with biological systems, it is possible to create micro-electrical mechanical systems that may revolutionize health care delivery.

  18. Jet stability in the lithium fall reactor

    International Nuclear Information System (INIS)

    Kang, S.W.

    1978-01-01

    A preliminary analysis has been made of the various hydrodynamic aspects involved in the stability of a liquid-lithium jet in a laser-fusion reactor, which comprises a part of LLL's laser fusion power-generation concept. Various physical factors that may affect the jet breakup are delineated, and some approximate calculations are performed to determine their relative influences. Areas of uncertainty are pointed out, along with plans for experimental verification or further theoretical analysis

  19. High power lasers & systems

    OpenAIRE

    Chatwin, Chris; Young, Rupert; Birch, Philip

    2015-01-01

    Some laser history;\\ud Airborne Laser Testbed & Chemical Oxygen Iodine Laser (COIL);\\ud Laser modes and beam propagation;\\ud Fibre lasers and applications;\\ud US Navy Laser system – NRL 33kW fibre laser;\\ud Lockheed Martin 30kW fibre laser;\\ud Conclusions

  20. Improved Thermoelectrically Cooled Laser-Diode Assemblies

    Science.gov (United States)

    Glesne, Thomas R.; Schwemmer, Geary K.; Famiglietti, Joe

    1994-01-01

    Cooling decreases wavelength and increases efficiency and lifetime. Two improved thermoelectrically cooled laser-diode assemblies incorporate commercial laser diodes providing combination of both high wavelength stability and broad wavelength tuning which are broadly tunable, highly stable devices for injection seeding of pulsed, high-power tunable alexandrite lasers used in lidar remote sensing of water vapor at wavelengths in vicinity of 727 nanometers. Provide temperature control needed to take advantage of tunability of commercial AlGaAs laser diodes in present injection-seeding application.

  1. Accelerated rotation with orbital angular momentum modes

    CSIR Research Space (South Africa)

    Schulze, C

    2015-01-01

    Full Text Available ] and generalized recently in the context of radial self-acceleration [23]. Such beams have been experimentally investigated in great detail [24–32]. The intensity maxima of these fields gyrate around the optical axis, forming a solenoidal shape, which has been used...(z�)]2 . (13) III. EXPERIMENT In our experiment a linearly polarized, single wavelength (λ = 632.8 nm) helium-neon laser (Melles Griot) with a power of 10 mW was expanded and collimated by a telescope (fL1 = 15 mm and fL2 = 125 mm) to approximate a plane...

  2. Long-gauge length embedded fiber optic ultrasonic sensor for large-scale concrete structures

    Science.gov (United States)

    Yuan, Libo; Zhou, Limin; Jin, Wei

    2004-02-01

    A fiber optic ultrasonic sensor based on Fizeau interferometer has been developed and demonstrated. A helium-neon laser light source with wavelength 0.6328 μm is used in our experiment. A special feature is its Fizeau configuration, which enables one to eliminate much undesirable noise by combining both the reference arm and the sensing arm within the same length of fiber. The dynamic response model of photo-elastic effect of ultrasonic wave and optical fiber is established. The fiber optic ultrasonic sensor experimental results are obtained and compared with the convenient PZT transducer.

  3. Semiconductor laser diodes and the design of a D.C. powered laser diode drive unit

    OpenAIRE

    Cappuccio, Joseph C., Jr.

    1988-01-01

    Approved for public release; distribution is unlimited This thesis addresses the design, development and operational analysis of a D.C. powered semiconductor laser diode drive unit. A laser diode requires an extremely stable power supply since a picosecond spike of current or power supply switching transient could result in permanent damage. The design offers stability and various features for operational protection of the laser diode. The ability to intensity modulate (analog) and pulse m...

  4. Laser targets: introduction

    International Nuclear Information System (INIS)

    Rosen, M.D.

    1985-01-01

    The laser target design group was engaged in three main tasks in 1984: (1) analyzing Novette implosion and hohlraum-scaling data, (2) planning for the first experiments on Nova, and (3) designing laboratory x-ray laser targets and experiments. The Novette implosion and hohlraum scaling data are mostly classified and are therefore not discussed in detail here. The authors achieved average final/initial pusher pr ratios of about 50, some 3 times higher than the value achieved in the best Shiva shots. These pr values imply a fuel compression to 100 times liquid density, although this figure and other aspects of the experiments are subject to further interpretation because of detailed questions of target symmetry and stability. Their main long-term goal for Nova is to produce a so-called hydrodynamically equivalent target (HET) - that is, a target whose hydrodynamic behavior (implosion velocity, convergence ratio, symmetry and stability requirements, etc.) is very much like that of a high-gain target, but one that is scaled down in size to match the energy available from Nova and is too small to achieve enough hot-spot pr to ignite the cold, near-Fermi-degenerate fuel around it. Their goal for Nova's first year is to do experiments that will teach them how to achieve the symmetry and stability conditions required by an HET

  5. Mirrorless lasers

    Indian Academy of Sciences (India)

    conventional laser, the random laser had one partially reflecting mirror for providing an output port, and a surface or volume scatterer at the other end to provide non-resonant feedback. The volume scatterer was a suspension of chalk particles (about 20 microns di- ameter), in water and surface scatterer was a plate with a ...

  6. excimer laser

    Indian Academy of Sciences (India)

    2014-01-07

    Jan 7, 2014 ... is necessary to deposit one order higher input electric power into gas medium than those required for XeCl and KrF lasers. ... neon/helium at a pressure of a few bars was excited by transverse electric discharge. The. Figure 6. Laser pulse ... and also to drive discharge rapidly. The discharge chamber was ...

  7. Laser yellowing

    Indian Academy of Sciences (India)

    environmental degradation of surfaces. Pulsed lasers are generally used for ... sorb contamination very strongly while the underlying substrate is left untouched thus rendering the process self-limiting. ... contaminated with two different encrustations, using short free running Nd:YAG and long Q-switched Nd:YAG laser ...

  8. Stopping atoms with diode lasers

    International Nuclear Information System (INIS)

    Watts, R.N.; Wieman, C.E.

    1986-01-01

    The use of light pressure to cool and stop neutral atoms has been an area of considerable interest recently. Cooled neutral atoms are needed for a variety of interesting experiments involving neutral atom traps and ultrahigh-resolution spectroscopy. Laser cooling of sodium has previously been demonstrated using elegant but quite elaborate apparatus. These techniques employed stabilized dye lasers and a variety of additional sophisticated hardware. The authors have demonstrated that a frequency chirp technique can be implemented using inexpensive diode lasers and simple electronics. In this technique the atoms in an atomic beam scatter resonant photons from a counterpropagating laser beam. The momentum transfer from the photons slows the atoms. The primary difficulty is that as the atoms slow their Doppler shift changes, and so they are no longer in resonance with the incident photons. In the frequency chirp technique this is solved by rapidly changing the laser frequency so that the atoms remain in resonance. To achieve the necessary frequency sweep with a dye laser one must use an extremely sophisticated high-speed electrooptic modulator. With a diode laser, however, the frequency can be smoothly and rapidly varied over many gigahertz simply by changing the injection current

  9. Macroeconomic stability

    DEFF Research Database (Denmark)

    Jespersen, Jesper

    2004-01-01

    It is demonstrated that full employment and sustainable development not necessarily are conflicting goals. On the other hand macroeconomic stability cannot be obtained without a deliberate labour sharing policy and a shift in the composition of private consumption away from traditional material...

  10. Injection locking of a high power ultraviolet laser diode for laser cooling of ytterbium atoms.

    Science.gov (United States)

    Hosoya, Toshiyuki; Miranda, Martin; Inoue, Ryotaro; Kozuma, Mikio

    2015-07-01

    We developed a high-power laser system at a wavelength of 399 nm for laser cooling of ytterbium atoms with ultraviolet laser diodes. The system is composed of an external cavity laser diode providing frequency stabilized output at a power of 40 mW and another laser diode for amplifying the laser power up to 220 mW by injection locking. The systematic method for optimization of our injection locking can also be applied to high power light sources at any other wavelengths. Our system does not depend on complex nonlinear frequency-doubling and can be made compact, which will be useful for providing light sources for laser cooling experiments including transportable optical lattice clocks.

  11. Stabilization flyuorytopodibnoyi structure in oxide vacuum condensate

    Directory of Open Access Journals (Sweden)

    О.М. Заславський

    2006-01-01

    Full Text Available  The influence of the oxide-stabilizer content, M'-cation radius and film deposition temperature on the stabilization of the fluorite-like solid solutions in the zirconium and hafnium oxides-based vacuum condensates, obtained by Laser-evaporating method, was investigated. The optimum parameters of the coatication of the isotropic thermostable coverings was determined. This results were explained by using of the high-speed condensation in vacuum theory.

  12. Synthesis and stabilization of oxide-based colloidal suspensions in organic media: application in the preparation of hybrids organic-inorganic materials for very high laser damage threshold coatings; Synthese et stabilisation de suspensions colloidales d'oxydes en milieu organique: application a la preparation de materiaux hybrides organiques-inorganiques pour des revetements a tres haute tenue au flux laser

    Energy Technology Data Exchange (ETDEWEB)

    Marchet, N.

    2008-02-15

    Multilayer coatings are widely used in optic and particular in the field of high power laser on the components of laser chains. The development of a highly reflective coating with a laser damage resistance requires the fine-tuning of a multilayer stack constituted by a succession alternated by materials with low and high refractive index. In order to limit the number of layers in the stack, refractive indexes must be optimized. To do it, an original approach consists in synthesizing new organic-inorganic hybrid materials satisfying the criteria of laser damage resistance and optimized refractive index. These hybrid materials are constituted by nano-particles of metal oxides synthesized by sol-gel process and dispersed in an organic polymer with high laser damage threshold. Nevertheless, this composite system requires returning both compatible phases between them by chemical grafting of alc-oxy-silanes or carboxylic acids. We showed that it was so possible to disperse in a homogeneous way these functionalized nano-particles in non-polar, aprotic solvent containing solubilized organic polymers, to obtain time-stable nano-composite solutions. From these organic-inorganic hybrid solutions, thin films with optical quality and high laser damage threshold were obtained. These promising results have permitted to realize highly reflective stacks, constituted by 7 pairs with optical properties in agreement with the theoretical models and high laser damage threshold. (author)

  13. Laser spectroscopy

    CERN Document Server

    Demtröder, Wolfgang

    Keeping abreast of the latest techniques and applications, this new edition of the standard reference and graduate text on laser spectroscopy has been completely revised and expanded. While the general concept is unchanged, the new edition features a broad array of new material, e.g., ultrafast lasers (atto- and femto-second lasers) and parametric oscillators, coherent matter waves, Doppler-free Fourier spectroscopy with optical frequency combs, interference spectroscopy, quantum optics, the interferometric detection of gravitational waves and still more applications in chemical analysis, medical diagnostics, and engineering.

  14. Laser spectroscopy

    CERN Document Server

    Demtröder, Wolfgang

    2008-01-01

    Keeping abreast of the latest techniques and applications, this new edition of the standard reference and graduate text on laser spectroscopy has been completely revised and expanded. While the general concept is unchanged, the new edition features a broad array of new material, e.g., frequency doubling in external cavities, reliable cw-parametric oscillators, tunable narrow-band UV sources, more sensitive detection techniques, tunable femtosecond and sub-femtosecond lasers (X-ray region and the attosecond range), control of atomic and molecular excitations, frequency combs able to synchronize independent femtosecond lasers, coherent matter waves, and still more applications in chemical analysis, medical diagnostics, and engineering.

  15. Stabilization effect of Weibel modes due to inverse bremsstrahlung ...

    Indian Academy of Sciences (India)

    2016-11-04

    Nov 4, 2016 ... Abstract. In this work, the Weibel instability due to inverse bremsstrahlung absorption in laser fusion plasma has been investigated. The stabilization effect due to the coupling of the self-generated magnetic field by Weibel instability with the laser wave field is explicitly showed. The main result obtained in ...

  16. Stabilization effect of Weibel modes due to inverse bremsstrahlung ...

    Indian Academy of Sciences (India)

    In this work, the Weibel instability due to inverse bremsstrahlung absorption in laser fusion plasma has been investigated. The stabilization effect due to the coupling of the self-generated magnetic field by Weibel instability with the laser wave field is explicitly showed. The main result obtained in this work is that the inclusion ...

  17. The role of defects in laser damage of multilayer coatings

    International Nuclear Information System (INIS)

    Kozlowski, M.R.; Chow, R.

    1993-01-01

    Laser induced damage to optical coatings is generally a localized phenomenon associated with coating defects. The most common of the defect types are the well-known nodule defect. This paper reviews the use of experiments and modeling to understand the formation of these defects and their interaction with laser light. Of particular interest are efforts to identify which defects are most susceptible to laser damage. Also discussed are possible methods for stabilizing these defects (laser conditioning) or preventing their initiation (source stabilization, spatter particle trapping)

  18. Laser Refractography

    CERN Document Server

    Rinkevichyus, B.S; Raskovskaya, I.L

    2010-01-01

    This book describes the basic principles of laser refractography, a flexible new diagnostic tool for measuring optically inhomogeneous media and flows. Laser refractography is based on digital imaging and computer processing of structured laser beam refraction (SLR) in inhomogeneous transparent media. Laser refractograms provide both qualitative and quantitative measurements and can be used for the study of fast and transient processes. In this book, the theoretical basis of refractography is explored in some detail, and experimental setups are described for measurement of transparent media using either 2D (passed radiation) or 3D (scattered radiation) refractograms. Specific examples and applications are discussed, including visualization of the boundary layer near a hot or cold metallic ball in water, and observation of edge effects and microlayers in liquids and gases. As the first book to describe this new and exciting technique, this monograph has broad cross-disciplinary appeal and will be of interest t...

  19. Laser Dentistry

    Science.gov (United States)

    ... a Better Job? Start by Visiting the Dentist Pacifiers Have Negative and Positive Effects Temporomandibular Joint Disorder ... speed up tooth whitening procedures. What are the benefits of using dental lasers? There are several advantages. ...

  20. Laser accelerators

    International Nuclear Information System (INIS)

    Willis, W.J.

    1977-01-01

    A brief discussion is given on the feasibility of using lasers to accelerate particle beams. A rough theory of operation is developed, and numerical results are obtained for an example equivalent to the Fermilab Accelerator

  1. Laser endoscopy.

    Science.gov (United States)

    McElvein, R B

    1981-11-01

    A carbon dioxide laser operating in the invisible infrared range (10.6 mu) generates a beam of energy that is almost completely absorbed by biological tissue with release of intense heat and rapid destruction. A laser attached to a rigid bronchoscope has been used in 18 patients ranging in age from 21 to 62 years to treat a variety of causes of airway obstruction. These include tracheal stenosis and granulation tissue (6 patients), adenoma (1), web (2), and carcinoma (9). The results were good in 15 and poor in 3 patients. However, all patients had an improved airway after laser treatment with the best results occurring in patients with benign, inflammatory disease. The advantages of the laser are a lack of bleeding, minimal edema after treatment, and minimal scar formation. The disadvantages are the expense of the machine, and the need for general anesthesia and direct visualization of the lesion.

  2. Il laser

    CERN Document Server

    Smith, William V

    1974-01-01

    Verso il 1960, il laser era ancora "una soluzione alla ricerca di un problema", ma fin dagli anni immediatamente successivi si è rivelato uno strumento insostituibile per le applicazioni più svariate.

  3. Laser bronchoscopy.

    Science.gov (United States)

    Duhamel, D R; Harrell, J H

    2001-11-01

    Because the lung cancer epidemic shows no signs of abating, little doubt exists that the need for interventional bronchoscopists will persist for many years to come. The Nd:YAG laser and the rigid bronchoscope remain crucial weapons in the fight against lung cancer. With more than 4000 published interventions pertaining to it, this combination is ideal for treating central airways obstruction. The safety and efficacy of laser bronchoscopy has been well established, and the reported incidence of complications is impressively low. If complications were to arise, a skilled bronchoscopist can manage them easily by using the beneficial attributes of the rigid bronchoscope. Many complications can be avoided by implementing the established safety procedures and techniques. A solid understanding of laser physics and tissue interactions is a necessity to anyone performing laser surgery. The team approach, relying on communication among the bronchoscopist, anesthesiologist, laser technician, and nurses, leads to a safer and more successful procedure. It is important to remember, however, that this is typically a palliative procedure, and therefore the focus should be on alleviating symptoms and improving quality of life. Unfortunately, because not every patient is a candidate for laser bronchoscopy, there are specific characteristics of endobronchial lesions that make them more or less amenable to resection. Each year a promising new technology is being developed, such as argon plasma coagulation, cryotherapy, and endobronchial electrosurgery. Although it is unclear what role these technologies will have, prospective controlled studies must be done to help clarify this question. The future may lay in combining these various technologies along with Nd:YAG laser bronchoscopy to maximize the therapeutic, palliative, and possibly even curative effect. As the experience of the medical community with Nd:YAG laser bronchoscopy continues to grow and as more health-care professionals

  4. Green lasers

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin

    2010-01-01

    Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range......Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range...

  5. Note: Digital laser frequency auto-locking for inter-satellite laser ranging.

    Science.gov (United States)

    Luo, Yingxin; Li, Hongyin; Yeh, Hsien-Chi

    2016-05-01

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  6. Note: Digital laser frequency auto-locking for inter-satellite laser ranging

    International Nuclear Information System (INIS)

    Luo, Yingxin; Yeh, Hsien-Chi; Li, Hongyin

    2016-01-01

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  7. Note: Digital laser frequency auto-locking for inter-satellite laser ranging

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Yingxin; Yeh, Hsien-Chi, E-mail: yexianji@mail.hust.edu.cn [MOE Key Laboratory of Fundamental Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China); Li, Hongyin [MOE Key Laboratory of Fundamental Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Automation, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2016-05-15

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  8. Chinese marketplace of lasers and laser materials

    Science.gov (United States)

    Zhu, Huanan

    1992-05-01

    Today I want to introduce the subject of laser materials in China. I will discuss the general background of lasers and laser materials in China. Second, I want to show you some recent rapid development of lasers and laser materials in China. Third, I want to give you an overview of key R&D centers and manufacturers of lasers and laser materials. Fourth, I want to analyze some important export trends from China. Finally, I want to say something about the active international cooperation in the field of lasers and laser materials.

  9. Robust Frequency Combs and Lasers for Optical Clocks and Sensing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Optical frequency combs are the key enabling technology that enabled the immense fractional stability of highly-stabilized lasers in the optical regime to be...

  10. Quantifying Stability in Complex Networks: From Linear to Basin Stability

    Science.gov (United States)

    Kurths, Jürgen

    The human brain, power grids, arrays of coupled lasers and the Amazon rainforest are all characterized by multistability. The likelihood that these systems will remain in the most desirable of their many stable states depends on their stability against significant perturbations, particularly in a state space populated by undesirable states. Here we claim that the traditional linearization-based approach to stability is in several cases too local to adequately assess how stable a state is. Instead, we quantify it in terms of basin stability, a new measure related to the volume of the basin of attraction. Basin stability is non-local, nonlinear and easily applicable, even to high-dimensional systems. It provides a long-sought-after explanation for the surprisingly regular topologies of neural networks and power grids, which have eluded theoretical description based solely on linear stability. Specifically, we employ a component-wise version of basin stability, a nonlinear inspection scheme, to investigate how a grid's degree of stability is influenced by certain patterns in the wiring topology. Various statistics from our ensemble simulations all support one main finding: The widespread and cheapest of all connection schemes, namely dead ends and dead trees, strongly diminish stability. For the Northern European power system we demonstrate that the inverse is also true: `Healing' dead ends by addition of transmission lines substantially enhances stability. This indicates a crucial smart-design principle for tomorrow's sustainable power grids: add just a few more lines to avoid dead ends. Further, we analyse the particular function of certain network motifs to promote the stability of the system. Here we uncover the impact of so-called detour motifs on the appearance of nodes with a poor stability score and discuss the implications for power grid design. Moreover, it will be shown that basin stability enables uncovering the mechanism for explosive synchronization and

  11. Tracking frequency laser distance gauge

    International Nuclear Information System (INIS)

    Phillips, J.D.; Reasenberg, R.D.

    2005-01-01

    Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require laser distance gauges of substantially improved performance. We describe a laser gauge, based on Pound-Drever-Hall locking, in which the optical frequency is adjusted to maintain an interferometer's null condition. This technique has been demonstrated with pm performance. Automatic fringe hopping allows it to track arbitrary distance changes. The instrument is intrinsically free of the nm-scale cyclic bias present in traditional (heterodyne) high-precision laser gauges. The output is a radio frequency, readily measured to sufficient accuracy. The laser gauge has operated in a resonant cavity, which improves precision, can suppress the effects of misalignments, and makes possible precise automatic alignment. The measurement of absolute distance requires little or no additional hardware, and has also been demonstrated. The proof-of-concept version, based on a stabilized HeNe laser and operating on a 0.5 m path, has achieved 10 pm precision with 0.1 s integration time, and 0.1 mm absolute distance accuracy. This version has also followed substantial distance changes as fast as 16 mm/s. We show that, if the precision in optical frequency is a fixed fraction of the linewidth, both incremental and absolute distance precision are independent of the distance measured. We discuss systematic error sources, and present plans for a new version of the gauge based on semiconductor lasers and fiber-coupled components

  12. D2O laser pumped by an injection-locked CO2 laser for ion-temperature measurements

    International Nuclear Information System (INIS)

    Okada, Tatsuo; Ohga, Tetsuaki; Yokoo, Masakazu; Muraoka, Katsunori; Akazaki, Masanori.

    1986-01-01

    The cooperative Thomson scattering method is one of the various new techniques proposed for measuring the temperature of ions in nuclear fusion critical plasma, for which a high-performance FIR laser pumped by an injection-locked CO 2 laser is required. This report deals with D 2 O laser with a wavelength of 385 μm which is pumped by injection-locked single-mole TEA CO 2 laser composed of a driver laser and an output-stage laser. A small-sized automatic pre-ionization type laser is employed for the driver. The resonator of the driver laser consists of a plane grating of littrow arrangement and ZnSe plane output mirrors with reflection factor of 50 %. An aperture and ZnSe etalon are inserted in the resonator to produce single transverse- and longitudinal-mode oscillation, respectively. The output-stage laser is also of the automatic pre-ionization type. Theoretically, an injection power of 0.1 pW/mm 3 is required for a CO 2 laser. Single-mode oscillation of several hundred nW/mm 3 can be produced by the CO 2 laser used in this study. Tuning of the output-stage laser is easily controlled by the driver laser. High stability of the injection-locked operation is demonstrated. CO 2 laser beam is introduced into the D 2 O laser through a KCl window to excite D 2 O laser beam in the axial direction. Input and output characteristics of the D 2 O laser are shown. Also presented are typical pulse shapes from the D 2 O laser pumped by a free-running CO 2 laser pulse or by an injection-locked single-mode CO 2 laser pulse. (Nogami, K.)

  13. Femtosecond laser technologies for linear collider designs

    CERN Document Server

    Kobayashi, K

    2001-01-01

    A highly stabilized high-energy femtosecond laser system was developed for Compton X-ray experiments. The laser system is based on the chirped pulse amplification, and each component is actively or passively stabilized. A master oscillator with less than 100 fs timing jitter, two independent oscillators with 300 fs relative timing lag, a new measurement technique of timing fluctuation of low-repetition amplified pulse, and a special designed regenerative amplifier with high quality beam were developed. New technical options for linear collider are proposed based on these expertises. The options are temporally square pulse for low emittance electron generation, a timing stabilized seeder for CO sub 2 amplifier, and multi-pulse high-energy lasers for gamma-gamma collision and for multi-bunch electron generation.

  14. Laser material processing

    CERN Document Server

    Steen, William

    2010-01-01

    This text moves from the basics of laser physics to detailed treatments of all major materials processing techniques for which lasers are now essential. New chapters cover laser physics, drilling, micro- and nanomanufacturing and biomedical laser processing.

  15. Femtosecond laser additive manufacturing of YSZ

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jian; Bai, Shuang [PolarOnyx, Inc., San Jose, CA (United States)

    2017-04-15

    Laser additive manufacturing (LAM) of Yttria-Stabilized Zirconia (YSZ) is investigated using femtosecond (fs) fiber lasers. Various processing conditions are studied, which leads to desired characteristics in terms of morphology, porosity, hardness, microstructural and mechanical properties of the processed components. High-density (>99%) YSZ part with refined grain and increased hardness was obtained. Microstructure features of fabricated specimens were studied with SEM, EDX, the measured micro hardness is achieved as high as 18.84 GPa. (orig.)

  16. An auto-locked diode laser system for precision metrology

    Science.gov (United States)

    Beica, H. C.; Carew, A.; Vorozcovs, A.; Dowling, P.; Pouliot, A.; Barron, B.; Kumarakrishnan, A.

    2017-05-01

    We present a unique external cavity diode laser system that can be auto-locked with reference to atomic and molecular spectra. The vacuum-sealed laser head design uses an interchangeable base-plate comprised of a laser diode and optical elements that can be selected for desired wavelength ranges. The feedback light to the laser diode is provided by a narrow-band interference filter, which can be tuned from outside the laser cavity to fineadjust the output wavelength in vacuum. To stabilize the laser frequency, the digital laser controller relies either on a pattern-matching algorithm stored in memory, or on first or third derivative feedback. We have used the laser systems to perform spectroscopic studies in rubidium at 780 nm, and in iodine at 633 nm. The linewidth of the 780-nm laser system was measured to be ˜500 kHz, and we present Allan deviation measurements of the beat note and the lock stability. Furthermore, we show that the laser system can be the basis for a new class of lidar transmitters in which a temperature-stabilized fiber-Bragg grating is used to generate frequency references for on-line points of the transmitter. We show that the fiber-Bragg grating spectra can be calibrated with reference to atomic transitions.

  17. Laser-Vorrichtung

    OpenAIRE

    Klein, J.

    1992-01-01

    The laser device has a laser oscillator and a downstream laser amplifier which has an entry zone for the laser beam, which comes from the laser oscillator before it is amplified, and an exit for the amplified laser beam. The laser amplifier also has a convolutional mirror which is opposite the entry zone for the laser beam to be amplified. The laser device is designed so that the amplifying medium in the laser amplifier can be optimally utilized if the laser device has a compact design. To th...

  18. PHARAO space atomic clock: new developments on the laser source

    Science.gov (United States)

    Saccoccio, Muriel; Loesel, Jacques; Coatantiec, Claude; Simon, Eric; Laurent, Philippe; Lemonde, Pierre; Maksimovic, I.; Abgrall, M.

    2017-11-01

    The PHARAO project purpose is to open the way for a new atomic clock generation in space, where laser cooling techniques and microgravity allow high frequency stability and accuracy. The French space agency, CNES is funding and managing the clock construction. The French SYRTE and LKB laboratories are scientific and technical advisers for the clock requirements and the follow-up of subsystem development in industrial companies. EADS SODERN is developing two main subsystems of the PHARAO clock: the Laser Source and the Cesium Tube where atoms are cooled, launched, selected and detected by laser beams. The Laser Source includes an optical bench and electronic devices to generate the laser beams required. This paper describes PHARAO and the role laser beams play in its principle of operation. Then we present the Laser Source design, the technologies involved, and the status of development. Lastly, we focus of a key equipment to reach the performances expected, which is the Extended Cavity Laser Diode.

  19. Laser deposition of HTSC films

    International Nuclear Information System (INIS)

    Sobol', Eh.N.; Bagratashvili, V.N.; Zherikhin, A.N.; Sviridov, A.P.

    1990-01-01

    Studies of the high-temperature superconducting (HTSC) films fabrication by the laser deposition are reviewed. Physical and chemical processes taking place during laser deposition are considered, such as the target evaporation, the material transport from the target to the substrate, the film growth on the substrate, thermochemical reactions and mass transfer within the HTSC films and their stability. The experimental results on the laser deposition of different HTSC ceramics and their properties investigations are given. The major technological issues are discussed including the deposition schemes, the oxygen supply, the target compositions and structure, the substrates and interface layers selection, the deposition regimes and their impact on the HTSC films properties. 169 refs.; 6 figs.; 2 tabs

  20. Single mode operation of a tea CO2 laser by a CW CO2 laser radiation injection

    International Nuclear Information System (INIS)

    Silakhori, K.; Soltanmoradi, F.; Behjat, A.; Montazerghaem, M.; Sadr, R.

    2005-01-01

    In this research work, single mode operation based on injection of a CW laser beam into TEA CO 2 laser cavity has been demonstrated. The technique has vast applications in research programs for laser spectroscopy and optical pumping. The observed smooth pulse shapes indicated that the system is operating in a single mode of operation, where no additional PZT mounted elements or other cavity stabilizing devices have been used. In addition, it have been observed that the output energy has not been reduced when the laser was operating in a single mode of operation, compared with the case when the laser is operating in the multi-mode regime

  1. Stabilized Optical Fiber Links for the XFEL

    CERN Document Server

    Winter, Axel; Grawert, Felix J; Ilday, Fatih O; Kaertner, Franz X; Kim, Jung-Won; Schlarb, Holger; Schmidt, Bernhard

    2005-01-01

    The timing synchronization scheme for the European X-Ray free electron laser facility (XFEL) is based on the generation and distribution of sub-picosecond laser pulses with actively stabilized repetition rate which are used to synchronize local RF oscillators. An integral part of the scheme is the distribution of the optical pulse stream to parts of the facility via optical fiber links. The optical path length of the fiber has to be stabilized against short-term and long-term timing jitter due to environmental effects, such as temperature drifts and acoustic vibrations, to better than 10 fs for distances ranging from tens of meters to several kilometers. In this paper, we present first experimental results for signal transmission through a km-long fiber link with femtosecond stability.

  2. Miniature Laser Magnetometer

    Science.gov (United States)

    Slocum, Robert; Brown, Andy

    2011-01-01

    A conceptual design has been developed for a miniature laser magnetometer (MLM) that will measure the scalar magnitude and vector components of near-Earth magnetic fields. The MLM incorporates a number of technical innovations to achieve high-accuracy and high-resolution performance while significantly reducing the size of the laser-pumped helium magnetometer for use on small satellites and unmanned aerial vehicles (UAVs). and electronics sections that has the capability of measuring both the scalar magnetic field magnitude and the vector magnetic field components. Further more, the high-accuracy scalar measurements are used to calibrate and correct the vector component measurements in order to achieve superior vector accuracy and stability. The correction algorithm applied to the vector components for calibration and the same cell for vector and scalar measurements are major innovations. The separate sensor and electronics section of the MLM instrument allow the sensor to be installed on a boom or otherwise located away from electronics and other noisy magnetic components. The MLM s miniaturization will be accomplished through the use of advanced miniaturized components and packaging methods for the MLM sensor and electronics. The MLM conceptual design includes three key innovations. The first is a new non-magnetic laser package that will allow the placement of the laser pump source near the helium cell sensing elements. The second innovation is the design of compact, nested, triaxial Braunbek coils used in the vector measurements that reduce the coil size by a factor of two compared to existing Helmholtz coils with similar field-generation performance. The third innovation is a compact sensor design that reduces the sensor volume by a factor of eight compared to MLM s predecessor.

  3. The Shipboard Employment of a Free Electron Laser Weapon System

    National Research Council Canada - National Science Library

    Allgaier, Gregory

    2003-01-01

    .... Considerations for this weapon system include employment, design, and stability. In order to reach a MW class laser, system parameters must be optimized and the high power optical beam must be appropriately managed...

  4. Thermal tuning On narrow linewidth fiber laser

    Science.gov (United States)

    Han, Peiqi; Liu, Tianshan; Gao, Xincun; Ren, Shiwei

    2010-10-01

    At present, people have been dedicated to high-speed and large-capacity optical fiber communication system. Studies have been shown that optical wavelength division multiplexing (WDM) technology is an effective means of communication to increase the channel capacity. Tunable lasers have very important applications in high-speed, largecapacity optical communications, and distributed sensing, it can provide narrow linewidth and tunable laser for highspeed optical communication. As the erbium-doped fiber amplifier has a large gain bandwidth, the erbium-doped fiber laser can be achieved lasing wavelength tunable by adding a tunable filter components, so tunable filter device is the key components in tunable fiber laser.At present, fiber laser wavelength is tuned by PZT, if thermal wavelength tuning is combined with PZT, a broader range of wavelength tuning is appearance . Erbium-doped fiber laser is used in the experiments,the main research is the physical characteristics of fiber grating temperature-dependent relationship and the fiber grating laser wavelength effects. It is found that the fiber laser wavelength changes continuously with temperature, tracking several temperature points observed the self-heterodyne spectrum and found that the changes in spectra of the 3dB bandwidth of less than 1kHz, and therefore the fiber laser with election-mode fiber Bragg grating shows excellent spectral properties and wavelength stability.

  5. Laser Heterodyning

    CERN Document Server

    Protopopov, Vladimir V

    2009-01-01

    Laser heterodyning is now a widespread optical technique, based on interference of two waves with slightly different frequencies within the sensitive area of a photo-detector. Its unique feature – preserving phase information about optical wave in the electrical signal of the photo-detector – finds numerous applications in various domains of applied optics and optoelectronics: in spectroscopy, polarimetry, radiometry, laser radars and Lidars, microscopy and other areas. The reader may be surprised by a variety of disciplines that this book covers and satisfied by detailed explanation of the phenomena. Very well illustrated, this book will be helpful for researches, postgraduates and students, working in applied optics.

  6. Laser beam diagnostics for metalworking applications

    International Nuclear Information System (INIS)

    Ramos, T.J.; Lingenfelter, A.C.

    1984-01-01

    The Materials Fabrication Division of Lawrence Livermore National Laboratory (LLNL) has three pulsed Nd-YAG lasers dedicated to metalworking. The units are used in a job shop primarily for welding. They also have a number of applications requiring cutting and drilling capability. Each of these metalworking operations requires somewhat different laser beam characteristics. As most investigators have found, the mode of the laser beam and the mode stability are the key variables which must be controlled if optimum results are to be achieved. The authors use several techniques to observe and measure these variables, i.e. Charge Couple Device (CCD) Camera, Thermal Image Plate and thermal-sensitive paper

  7. Multi-terawatt fusion laser systems

    International Nuclear Information System (INIS)

    Holzrichter, J.F.

    1993-01-01

    The evolution of laser fusion systems started with a description of the basic principles of the laser in 1959, then a physical demonstration showing 1000 Watts of peak optical power in 1961 to the present systems that deliver 10 14 watts of peak optical power, are presented. Physical limits to large systems are reviewed: thermal limits, material stress limits, structural limits and stability, parasitic coupling, measurement precision and diagnostics. The various steps of the fusion laser-system development process are then discussed through an historical presentation. 3 figs., 8 refs

  8. Laser Cooled Atomic Clocks in Space

    Science.gov (United States)

    Thompson, R. J.; Kohel, J.; Klipstein, W. M.; Seidel, D. J.; Maleki, L.

    2000-01-01

    The goals of the Glovebox Laser-cooled Atomic Clock Experiment (GLACE) are: (1) first utilization of tunable, frequency-stabilized lasers in space, (2) demonstrate laser cooling and trapping in microgravity, (3) demonstrate longest 'perturbation-free' interaction time for a precision measurement on neutral atoms, (4) Resolve Ramsey fringes 2-10 times narrower than achievable on Earth. The approach taken is: the use of COTS components, and the utilization of prototype hardware from LCAP flight definition experiments. The launch date is scheduled for Oct. 2002. The Microgravity Science Glovebox (MSG) specifications are reviewed, and a picture of the MSG is shown.

  9. The SwissFEL Experimental Laser facility.

    Science.gov (United States)

    Erny, Christian; Hauri, Christoph Peter

    2016-09-01

    The hard X-ray laser SwissFEL at the Paul Scherrer Institute is currently being commissioned and will soon become available for users. In the current article the laser facility is presented, an integral part of the user facility, as most time-resolved experiments will require a versatile optical laser infrastructure and precise information about the relative delay between the X-ray and optical pulse. The important key parameters are a high availability and long-term stability while providing advanced laser performance in the wavelength range from ultraviolet to terahertz. The concept of integrating a Ti:sapphire laser amplifier system with subsequent frequency conversion stages and drift compensation into the SwissFEL facility environment for successful 24 h/7 d user operation is described.

  10. An active interferometer-stabilization scheme with linear phase control

    DEFF Research Database (Denmark)

    Vardhan Krishnamachari, Vishnu; Andresen, Esben Ravn; Potma, Eric Olaf

    2006-01-01

    We report a simple and robust computer-based active interferometer stabilization scheme which does not require modulation of the interfering beams and relies on an error signal which is linearly related to the optical path difference. In this setup, a non-collinearly propagating reference laser...... beam stabilizes the interference output of the laser light propagating collinearly through the interferometer. This stabilization scheme enables adjustable phase control with 20 ms switching times in the range from 0.02π radians to 6π radians at 632.8 nm....

  11. Fuzzy logic control of a nitrogen laser

    Science.gov (United States)

    Tam, Siu Chung; Tan, Siong-Chai; Neo, Wah-Peng; Foong, Sze-Chern; Chan, Choon-Hao; Ho, Anthony T.; Chua, Hock-Chuan; Lee, Sing

    2001-02-01

    Traditionally, the stability of the output of a laser is controlled through scientific means or by a simple feedback loop. For multiinput multioutput control and for medium- to high-power lasers, however, these control schemes may break down. We report on the use of a fuzzy logic control scheme to improve the stability of a pulsed nitrogen laser. Specifically, the nitrogen laser is modeled as a two-input two-output system. The two input parameters are the discharge voltage (V) and nitrogen pressure (P), and the two output parameters are the pulse energy (E) and pulse width (PW). The performance of the fuzzy logic controller is compared with a decoupled two-channel PID (proportional+integral+derivative) controller. In our experiment, the long-term stabilities of the open-loop system are 1.82% root mean square (rms) for pulse energy and 4.58% rms for pulse width. The PID controller achieves better performance with long-term stabilities of 1.46% rms for pulse energy and 4.46% rms for pulse width. The fuzzy logic controller performs the best with long-term stabilities of 1.02% rms for pulse energy and 4.24% rms for pulse width, respectively.

  12. Design of directional prism resonator made DPL operate in TEM00 mode with thermal stability

    Science.gov (United States)

    Lu, Changyong; Wang, Xiaobing; Sun, Bin; Guo, Yanlong; Wang, Guchang; Lin, Yi; Wan, Qiang

    2005-01-01

    An alignment-free directional prism resonator that ensures the laser TEM00 mode with thermal stability in a certain range is designed by using g* parameter equivalent method. The output of all solid state laser is about of 150mJ, and the beam divergence is of 3mrad with 20Hz repetition rate, moreover, when the laser operates from 10 to 30Hz, the beam divergence is steady. This laser meets the needs of special engineering application.

  13. Thermal annealing of femtosecond laser written structures in silica glass

    NARCIS (Netherlands)

    Witcher, J.J.; Reichman, W.B.; Fletcher, L.B.; Troy, N.W.; Krol, D.M.

    2013-01-01

    We have investigated the thermal stability of femtosecond laser modification inside fused silica. Raman and FL spectroscopy show that fs-laser induced non-bridging oxygen hole center (NBOHC) defects completely disappear at 300 °C, whereas changes in Si-O ring structures only anneal out after heat

  14. Resonator fiber optic gyro employing a semiconductor laser.

    Science.gov (United States)

    Jin, Zhonghe; Yu, Xuhui; Ma, Huilian

    2012-05-20

    Resonator fiber optic gyro (RFOG) based on the Sagnac effect has the potential to achieve the inertial navigation system requirement with a short sensing coil. Semiconductor laser is one of the key elements for integration and miniaturization of the RFOG. In this paper, an RFOG employing a semiconductor laser is demonstrated. The model of the laser frequency noise induced error in the RFOG is described. To attenuate the laser frequency noise induced error, active frequency stabilization is applied. An online laser frequency noise observation is built, as a powerful optimum criterion for the loop parameters. Moreover, the laser frequency noise observation method is developed as a new measurement tool. With a fast digital proportional integrator based on a single field programmable gate array applied in the active stabilization loop, the laser frequency noise is reduced to 0.021 Hz (1σ). It is equivalent to a rotation rate of 0.07°/h, and close to the shot noise limit for the RFOG. As a result, a bias stability of open-loop gyro output is 9.5°/h (1σ) for the integration time 10 s in an hour observed in the RFOG. To the best of our knowledge, this result is the best long-term stability using the miniature semiconductor laser.

  15. Laser Dyes

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 15; Issue 9. Laser Dyes. G S Shankarling K J Jarag. General Article Volume 15 Issue 9 September ... Author Affiliations. G S Shankarling1 K J Jarag1. Dyestuff Technology, Department Institute of Chemical Technology, Matunga Mumbai 400 019, India.

  16. Laser heterodyning

    National Research Council Canada - National Science Library

    Protopopov, V. V

    2009-01-01

    ..., radiometry, laser radars and lidars, microscopy and other areas. Therefore, it is remarkable that such a widely used optical phenomenon has never before been comprehensively reviewed in a single work, as has been done many times for other subjects such as interferometry. I think there are several possible reasons for this. Perhap...

  17. Laser yellowing

    Indian Academy of Sciences (India)

    Author Affiliations. M B Sai Prasad1 Salvatore Siano2. Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai 400 085, India; CNR-IFAC, Polo Scientifico di Sesto Fiorentino, Via Madonna del Piano, 10, Sesto Fiorentino (FI)-50019, Italy ...

  18. Laser device

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention provides a light source for light circuits on a silicon platform. A vertical laser cavity is formed by a gain region arranged between a first mirror structure and a second mirror structure, both acting as mirrors, by forming a grating region including an active material...

  19. Mirrorless lasers

    Indian Academy of Sciences (India)

    Abstract. Experimental realization of mirrorless lasers in the last decade have resulted in hectic activity in this field, due to their novelty, simplicity and ruggedness and their great potential for application. In this article, I will review the various developments in this field in roughly chronological order, and discuss some possible ...

  20. Nanowire Lasers

    Directory of Open Access Journals (Sweden)

    Couteau C.

    2015-05-01

    Full Text Available We review principles and trends in the use of semiconductor nanowires as gain media for stimulated emission and lasing. Semiconductor nanowires have recently been widely studied for use in integrated optoelectronic devices, such as light-emitting diodes (LEDs, solar cells, and transistors. Intensive research has also been conducted in the use of nanowires for subwavelength laser systems that take advantage of their quasione- dimensional (1D nature, flexibility in material choice and combination, and intrinsic optoelectronic properties. First, we provide an overview on using quasi-1D nanowire systems to realize subwavelength lasers with efficient, directional, and low-threshold emission. We then describe the state of the art for nanowire lasers in terms of materials, geometry, andwavelength tunability.Next,we present the basics of lasing in semiconductor nanowires, define the key parameters for stimulated emission, and introduce the properties of nanowires. We then review advanced nanowire laser designs from the literature. Finally, we present interesting perspectives for low-threshold nanoscale light sources and optical interconnects. We intend to illustrate the potential of nanolasers inmany applications, such as nanophotonic devices that integrate electronics and photonics for next-generation optoelectronic devices. For instance, these building blocks for nanoscale photonics can be used for data storage and biomedical applications when coupled to on-chip characterization tools. These nanoscale monochromatic laser light sources promise breakthroughs in nanophotonics, as they can operate at room temperature, can potentially be electrically driven, and can yield a better understanding of intrinsic nanomaterial properties and surface-state effects in lowdimensional semiconductor systems.

  1. Single-frequency diode-pumped Nd:YAG prism laser with use of a composite laser crystal

    DEFF Research Database (Denmark)

    Pedersen, Christian; Hansen, P. L.; Buchhave, Preben

    1997-01-01

    A compact, stable, diode-pumped Nd:YAG laser suitable for high-power single-frequency operation is investigated theoretically as well as experimentally. Residual spatial hole burning has been eliminated with a unidirectional ring-laser design with a specially designed intracavity prism and a comp...... and a composite YAG laser crystal. A detailed Jones matrix analysis is performed, leading to design criteria for high loss difference and high-frequency stability....

  2. Direct Laser Cooling Al{}^{+} Ion Optical Clocks

    Science.gov (United States)

    Zhang, Jie; Deng, Ke; Luo, Jun; Lu, Ze-Huang

    2017-05-01

    The Al{}+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al{}+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al{}+ traps are utilized. The first trap is used to trap a large number of Al{}+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al{}+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach 9.0× {10}-17/\\sqrt{τ }. For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1× {10}-18. The proposed Al{}+ ion optical clock has the potential to become the most accurate and stable optical clock. Supported by the National Basic Research Program of China under Grant No 2012CB821300, the National Natural Science Foundation of China under Grant Nos 91336213, 11304109, 91536116 and 11174095, and the Program for New Century Excellent Talents by the Ministry of Education under Grant No NCET-11-0176.

  3. Effects of passive isolation on several optically pumped far-infrared laser lines

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, D.K.; Tesauro, G.J.; Johnson, L.C.; Semet, A.

    1981-05-01

    The effects of a recently introduced passive-isolation scheme for optically pumped far-infrared lasers have been investigated on several well-known far-infrared laser lines. In addition to increasing the laser output stability, the isolation scheme alters the pump-to-far-infrared power-conversion efficiency and the polarization state of the far-infrared output.

  4. All-fiber 7x1 signal combiner for incoherent laser beam combining

    DEFF Research Database (Denmark)

    Noordegraaf, Danny; Maack, Martin D.; Skovgaard, Peter M. W.

    2011-01-01

    We demonstrate an all-fiber 7x1 signal combiner for incoherent laser beam combining. This is a potential key component for reaching several kW of stabile laser output power. The combiner couples the output from 7 single-mode (SM) fiber lasers into a single multi-mode (MM) fiber. The input signal ...

  5. Excimer Laser Technology

    CERN Document Server

    Basting, Dirk

    2005-01-01

    This comprehensive survey on Excimer Lasers investigates the current range of the technology, applications and devices of this commonly used laser source, as well as the future of new technologies, such as F2 laser technology. Additional chapters on optics, devices and laser systems complete this compact handbook. A must read for laser technology students, process application researchers, engineers or anyone interested in excimer laser technology. An effective and understandable introduction to the current and future status of excimer laser technology.

  6. Experimental Performance of a Single-Mode Ytterbium-doped Fiber Ring Laser with Intracavity Modulator

    Science.gov (United States)

    Numata, Kenji; Camp, Jordan

    2012-01-01

    We have developed a linearly polarized Ytterbium-doped fiber ring laser with a single longitudinal mode output at 1064 run. A fiber-coupled intracavity phase modulator ensured mode-hop free operation and allowed fast frequency tuning. The fiber laser was locked with high stability to an iodine-stabilized laser, showing a frequency noise suppression of a factor approx 10 (exp 5) at 1 mHz

  7. Laser Division report 1986-89

    International Nuclear Information System (INIS)

    Monga, J.C.

    1995-01-01

    This report is a technical account of the scientific R and D activities pursued by the Laser Division of the Bhabha Atomic Research Centre during 1986-89. It covers in considerable detail, progress made in all the activities undertaken during that period in laser development and their application. The most important among them was the development of the 1 kJ glass laser. Studies of laser produced plasmas were pursued using a smaller 50 J chain and at different stages of development of the 1 kJ chain. Significant results of plasma instabilities and x-ray spectroscopic studies are reported. Several plasma diagnostic tools developed are also described which studied plasmas, radiation transport, and ablation induced shocks. Studies were also conducted on the performance of dye lasers during their development. Development of several CO 2 lasers, cw, pulsed, hybrid and wavelength turned/stabilized, have been described and their performance evaluated. Development and performance of a 16μ CF 4 laser is also given. An electron beam controlled CO 2 laser design is reported. (author). refs., figs., tabs

  8. Keck II laser guide star AO system and performance with the TOPTICA/MPBC laser

    Science.gov (United States)

    Chin, Jason C. Y.; Wizinowich, Peter; Wetherell, Ed; Lilley, Scott; Cetre, Sylvain; Ragland, Sam; Medeiros, Drew; Tsubota, Kevin; Doppmann, Greg; Otarola, Angel; Wei, Kai

    2016-07-01

    The Keck II Laser Guide Star (LGS) Adaptive Optics (AO) System was upgraded from a dye laser to a TOPTICA/MPBC Raman-Fibre Amplification (RFA) laser in December 2015. The W. M. Keck Observatory (WMKO) has been operating its AO system with a LGS for science since 2004 using a first generation 15 W dye laser. Using the latest diode pump laser technology, Raman amplification, and a well-tuned second harmonic generator (SHG), this Next Generation Laser (NGL) is able to produce a highly stable 589 nm laser beam with the required power, wavelength and mode quality. The beam's linear polarization and continuous wave format along with optical back pumping are designed to improve the sodium atom coupling efficiency over previously operated sodium-wavelength lasers. The efficiency and operability of the new laser has also been improved by reducing its required input power and cooling, size, and the manpower to operate and maintain it. The new laser has been implemented on the telescope's elevation ring with its electronics installed on a new Nasmyth sub-platform, with the capacity to support up to three laser systems for future upgrades. The laser is projected from behind the telescope's secondary mirror using the recently implemented center launch system (CLS) to reduce LGS spot size. We will present the new laser system and its performance with respect to power, stability, wavelength, spot size, optical repumping, polarization, efficiency, and its return with respect to pointing alignment to the magnetic field. Preliminary LGSAO performance is presented with the system returning to science operations. We will also provide an update on current and future upgrades at the WMKO.

  9. Laser Accelerator

    Science.gov (United States)

    2014-09-01

    Photocathode emitters eject electrons from the cathode by the photoelectric effect. A drive laser source shines light energy onto a metal or...synchronized so that the electrons ejected via the photoelectric effect are properly accelerated. 15 Figure 2.4: Cross-section of a triple spoke cavity, from...2.3: Available Pulsed Magnets at PFF LANL. SP = Short Pulse. MP = Mid-Pulse, after [19] Cell No. Magnet Pulse Duration (ms) Bore (mm) 1 50 T SP 25 24

  10. A 50 Mw Pulse-Forming Network with a Voltage Stability within 0.03-Percent

    NARCIS (Netherlands)

    Meddens, B. J. H.; Delmee, P. F. M.; van Amersfoort, P. W.

    1993-01-01

    Requirements on electron energy stability are extremely tight for operation of a free-electron laser. In case a radio-frequency field is used to accelerate the electrons, this leads to stringent requirements on the stability of the klystron output power and, hence, on the stability of the source

  11. Project LASER

    Science.gov (United States)

    1990-01-01

    NASA formally launched Project LASER (Learning About Science, Engineering and Research) in March 1990, a program designed to help teachers improve science and mathematics education and to provide 'hands on' experiences. It featured the first LASER Mobile Teacher Resource Center (MTRC), is designed to reach educators all over the nation. NASA hopes to operate several MTRCs with funds provided by private industry. The mobile unit is a 22-ton tractor-trailer stocked with NASA educational publications and outfitted with six work stations. Each work station, which can accommodate two teachers at a time, has a computer providing access to NASA Spacelink. Each also has video recorders and photocopy/photographic equipment for the teacher's use. MTRC is only one of the five major elements within LASER. The others are: a Space Technology Course, to promote integration of space science studies with traditional courses; the Volunteer Databank, in which NASA employees are encouraged to volunteer as tutors, instructors, etc; Mobile Discovery Laboratories that will carry simple laboratory equipment and computers to provide hands-on activities for students and demonstrations of classroom activities for teachers; and the Public Library Science Program which will present library based science and math programs.

  12. Thick tool steel coatings with laser cladding

    NARCIS (Netherlands)

    Ocelik, V.; de Oliveira, U.; De Hosson, J. Th. M.; DeHosson, JTM; Brebbia, CA; Nishida, SI

    2007-01-01

    This paper concentrates on thick and crack-free laser clad coatings (up to 3 mm). The coating material is a chromium-molybdenum-tungsten-vanadium alloyed high-speed steel that shows high wear resistance, high compressive strength, good toughness, very good dimensional stability on heat treatment and

  13. Pulsed laser excitation of phosphate stabilised silver nanoparticles

    Indian Academy of Sciences (India)

    Pulsed laser excitation; silver nanoparticles; surface plasmon band; sodium polyphosphate stabilizer. 1. ... are one of the most widely studied and well characterised metal systems due to the high stability of the silver ... processes occur by electron–phonon interactions and phonon cooling mechanism via phonon–solvent ...

  14. Laser power supply

    International Nuclear Information System (INIS)

    Bernstein, D.

    1975-01-01

    The laser power supply includes a regulator which has a high voltage control loop based on a linear approximation of a laser tube negative resistance characteristic. The regulator has independent control loops for laser current and power supply high voltage

  15. Laser therapy for cancer

    Science.gov (United States)

    ... Yag lasers. These lasers are used to treat cancer of the uterus, colon, and esophagus. The laser-emitting fibers are put inside a tumor to heat up and damage the cancer cells. This treatment has been used to shrink ...

  16. Laser fusion: an overview

    International Nuclear Information System (INIS)

    Boyer, K.

    1975-01-01

    The laser fusion concept is described along with developments in neodymium and carbon dioxide lasers. Fuel design and fabrication are reviewed. Some spin-offs of the laser fusion program are discussed. (U.S.)

  17. Laser therapy (image)

    Science.gov (United States)

    A laser is used for many medical purposes. Because the laser beam is so small and precise, it enables ... without injuring surrounding tissue. Some uses of the laser are retinal surgery, excision of lesions, and cauterization ...

  18. Laser Research Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Laser Research lab is thecenter for the development of new laser sources, nonlinear optical materials, frequency conversion processes and laser-based sensors for...

  19. Investigation of dye laser excitation of atomic systems

    International Nuclear Information System (INIS)

    Abate, J.A.

    1977-01-01

    A stabilized cw dye laser system and an optical pumping scheme for a sodium atomic beam were developed, and the improvements over previously existing systems are discussed. A method to stabilize both the output intensity and the frequency of the cw dye laser for periods of several hours is described. The fluctuation properties of this laser are investigated by photon counting and two-time correlation measurements. The results show significant departures from the usual single-mode laser theory in the region of threshold and below. The implications of the deviation from accepted theory are discussed. The atomic beam system that was constructed and tested is described. A method of preparing atomic sodium so that it behaves as a simple two-level atom is outlined, and the results of some experiments to study the resonant interaction between the atoms and the dye laser beam are presented

  20. Multi-longitudinal-mode micro-laser model

    Science.gov (United States)

    Staliunas, Kestutis

    2017-10-01

    We derive a convenient model for broad aperture micro-lasers, such as microchip lasers, broad area semiconductor lasers, or VCSELs, taking into account several longitudinal mode families. We provide linear stability analysis, and show characteristic spatio-temporal dynamics in such multi-longitudinal mode laser models. Moreover, we derive the coupled mode model in the presence of intracavity refraction index modulation (intracavity photonic crystal). Contribution to the Topical Issue "Theory and Applications of the Lugiato-Lefever Equation", edited by Yanne K. Chembo, Damia Gomila, Mustapha Tlidi, Curtis R. Menyuk.

  1. Arm Locking for the Laser Interferometer Space Antenna

    Science.gov (United States)

    Maghami, P. G.; Thorpe, J. I.; Livas, J.

    2009-01-01

    The Laser Interferometer Space Antenna (LISA) mission is a planned gravitational wave detector consisting of three spacecraft in heliocentric orbit. Laser interferometry is used to measure distance fluctuations between test masses aboard each spacecraft to the picometer level over a 5 million kilometer separation. Laser frequency fluctuations must be suppressed in order to meet the measurement requirements. Arm-locking, a technique that uses the constellation of spacecraft as a frequency reference, is a proposed method for stabilizing the laser frequency. We consider the problem of arm-locking using classical optimal control theory and find that our designs satisfy the LISA requirements.

  2. 280  GHz dark soliton fiber laser.

    Science.gov (United States)

    Song, Y F; Guo, J; Zhao, L M; Shen, D Y; Tang, D Y

    2014-06-15

    We report on an ultrahigh repetition rate dark soliton fiber laser. We show both numerically and experimentally that by taking advantage of the cavity self-induced modulation instability and the dark soliton formation in a net normal dispersion cavity fiber laser, stable ultrahigh repetition rate dark soliton trains can be formed in a dispersion-managed cavity fiber laser. Stable dark soliton trains with a repetition rate as high as ∼280  GHz have been generated in our experiment. Numerical simulations have shown that the effective gain bandwidth limitation plays an important role on the stabilization of the formed dark solitons in the laser.

  3. Studies on the separation of hydrogen isotopes and spin isomers by gas chromatography

    International Nuclear Information System (INIS)

    Pushpa, K.K.; Annaji Rao, K.

    2000-08-01

    Separation and analysis of mixture of hydrogen isotopes has gained considerable importance because of various applications needing different isotopes in lasers, nuclear reactions and tracer or labelled compounds. In the literature gas chromatographic methods are reported using columns packed with partly dehydrated or thoroughly dehydrated alumina/molecular sieve stationary phase at 77 deg K with helium, neon and even hydrogen or deuterium as carrier gas. In the present study an attempt is made to compare the chromatographic behaviour of these two stationary phases using virgin and Fe doped form in partly dehydrated and thoroughly dehydrated state, using helium, neon, hydrogen and deuterium as carrier gas. The results of this study show that helium or neon carrier gas behave similarly broad peaks with some tailing. Sharp symmetric peaks are obtained with hydrogen or deuterium carrier gas. This is attributed to large hold up capacity for H 2 or D 2 at 77 deg K in these materials as compared to helium or neon. Spin isomers of H 2 or D 2 are separated on Fe free stationary phases, though ortho H 2 and HD are not resolved. Using a combination of Fe doped short column and plain alumina column, both maintained in dehydrated form, the effect of Fe doping on thermal equilibrium of ortho/para forms at 77 deg K is clearly demonstrated. (author)

  4. Carbon in Fly Ash Analysis Using Photoacoustic Spectroscopy.

    Science.gov (United States)

    Dykstra, Jeffrey Raymond

    Photoacoustic absorption spectroscopy (PAS) was investigated as a method for on-line monitoring of carbon in fly ash from coal-fired boilers. PAS is based on the periodic heating of a gas when amplitude-modulated radiation is absorbed by the gas or by particles suspended in the gas. This periodic heating produces an acoustical wave that can be detected by a microphone. Because the PAS signal is based solely on the absorption of radiation (by carbon) and not scattering of radiation (by mineral matter), it has the potential for distinguishing unburned carbon from mineral matter suspended in the flue gas. Two radiation sources were studied: helium-neon laser and microwaves. The helium-neon source produces a large mass specific absorption coefficient for the carbon in the fly ash. Although the optical PAS system uses less than one forty thousandths of the power as the microwave system, it still has twice the sensitivity (D etam) and the microwave source (lambda = 12.24 cm). It may be possible to find a source that has all the positive characteristics with manageable drawbacks.

  5. Real-time monitoring of atom vapor concentration with laser absorption spectroscopy

    International Nuclear Information System (INIS)

    Fan Fengying; Gao Peng; Jiang Tao

    2012-01-01

    The technology of laser absorption spectroscopy was used for real-time monitoring of gadolinium atom vapor concentration measurement and the solid state laser pumped ring dye laser was used as optical source. The optical fiber was taken to improve the stability of laser transmission. The multi-pass absorption technology combined with reference optical signal avoided the influence of laser power fluctuation. The experiment result shows that the system based on this detection method has a standard error of 4%. It is proved that the monitoring system provides reliable data for atom vapor laser isotope separation process and the separation efficiency can be improved. (authors)

  6. Laser safety at high profile laser facilities

    International Nuclear Information System (INIS)

    Barat, K.

    2010-01-01

    Complete text of publication follows. Laser safety has been an active concern of laser users since the invention of the laser. Formal standards were developed in the early 1970's and still continue to be developed and refined. The goal of these standards is to give users guidance on the use of laser and consistent safety guidance and requirements for laser manufacturers. Laser safety in the typical research setting (government laboratory or university) is the greatest challenge to the laser user and laser safety officer. This is due to two factors. First, the very nature of research can put the user at risk; consider active manipulation of laser optics and beam paths, and user work with energized systems. Second, a laser safety culture that seems to accept laser injuries as part of the graduate student educational process. The fact is, laser safety at research settings, laboratories and universities still has long way to go. Major laser facilities have taken a more rigid and serious view of laser safety, its controls and procedures. Part of the rationale for this is that these facilities draw users from all around the world presenting the facility with a work force of users coming from a wide mix of laser safety cultures. Another factor is funding sources do not like bad publicity which can come from laser accidents and a poor safety record. The fact is that injuries, equipment damage and lost staff time slow down progress. Hence high profile/large laser projects need to adapt a higher safety regimen both from an engineering and administrative point of view. This presentation will discuss all these points and present examples. Acknowledgement. This work has been supported by the University of California, Director, Office of Science.

  7. Research of time fiducial and imaging VISAR laser for Shenguang-III laser facility

    Science.gov (United States)

    Zhang, Rui; Wang, Zhenguo; Tian, Xiaocheng; Zhou, Dandan; Zhu, Na; Wang, Jianjun; Li, Mingzhong; Xu, Dangpeng; Dang, Zhao; Hu, Dongxia; Zhu, Qihua; Zheng, Wanguo; Wang, Feng

    2015-10-01

    Time fiducial laser is an important tool for the precise measurement in high energy density physics experiments. The VISAR probe laser is also vital for shock wave diagnostics in ICF experiments. Here, time fiducial laser and VISAR light were generated from one source on SG-III laser facility. After generated from a 1064-nm DFB laser, the laser is modulated by an amplitude modulator driven by 10 GS/s arbitrary waveform generator. Using time division multiplexing technology, the ten-pulse time fiducial laser and the 20-ns VISAR pulse were split by a 1×2 multiplexer and then chosen by two acoustic optic modulators. Using the technique, cost of the system was reduced. The technologies adopted in the system also include pulse polarization stabilization, high precision fiber coupling and energy transmission. The time fiducial laser generated synchronized 12-beam 2ω and 4-beam 3ω laser, providing important reference marks for different detectors and making it convenient for the analysis of diagnostic data. After being amplified by fiber amplifiers and Nd:YAG rod amplifiers, the VISAR laser pulse was frequency-converted to 532-nm pulse by a thermally controlled LBO crystal with final output energy larger than 20 mJ. Finally, the green light was coupled into a 1-mm core diameter, multimode fused silica optical fiber and propagated to the imaging VISAR. The VISAR laser has been used in the VISAR diagnostic physics experiments. Shock wave loading and slowdown processes were measured. Function to measure velocity history of shock wave front movement in different kinds of materials was added to the SG-III laser facility.

  8. Resonant laser ionization of radioactive atoms

    CERN Document Server

    Köster, U; Mishin, V I

    2003-01-01

    Intense radioactive ion beams are produced by the isotope separation on-line method. The resonance ionization laser ion source (RILIS) can provide the chemical selectivity to separate beams with reduced isobaric contamination. The hot cavity RILIS at ISOLDE (CERN) uses copper vapor laser pumped dye lasers for the resonant transitions. Up to now 22 elements have been ionized with efficiencies of the order of 10%. Additional elements have been ionized with similar RILIS set- ups at the Institute of Spectroscopy (Troitsk), IRIS (Gatchina), Mainz University and TIARA (Takasaki). Ideas are discussed for future developments of this type of RILIS, which could further improve the efficiency, selectivity, rapidity of release and stability of the operation. The RILIS can also be applied for atomic spectroscopy studies of exotic radioactive isotopes, which are produced at rates of few atoms per second only. An interesting parallel is shown to the atomic vapor laser isotope separation (AVLIS), a large-scale application o...

  9. Laser satellite power systems

    Energy Technology Data Exchange (ETDEWEB)

    Walbridge, E.W.

    1980-01-01

    A laser satellite power system (SPS) converts solar power captured by earth-orbiting satellites into electrical power on the earth's surface, the satellite-to-ground transmission of power being effected by laser beam. The laser SPS may be an alternative to the microwave SPS. Microwaves easily penetrate clouds while laser radiation does not. Although there is this major disadvantage to a laser SPS, that system has four important advantages over the microwave alternative: (1) land requirements are much less, (2) radiation levels are low outside the laser ground stations, (3) laser beam sidelobes are not expected to interfere with electromagnetic systems, and (4) the laser system lends itself to small-scale demonstration. After describing lasers and how they work, the report discusses the five lasers that are candidates for application in a laser SPS: electric discharge lasers, direct and indirect solar pumped lasers, free electron lasers, and closed-cycle chemical lasers. The Lockheed laser SPS is examined in some detail. To determine whether a laser SPS will be worthy of future deployment, its capabilities need to be better understood and its attractiveness relative to other electric power options better assessed. First priority should be given to potential program stoppers, e.g., beam attenuation by clouds. If investigation shows these potential program stoppers to be resolvable, further research should investigate lasers that are particularly promising for SPS application.

  10. Semiconductor Laser Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Laser Measurements Laboratory is equipped to investigate and characterize the lasing properties of semiconductor diode lasers. Lasing features such...

  11. Laser Protection TIL

    Data.gov (United States)

    Federal Laboratory Consortium — The Laser Protection TIL conducts research and analysis of laser protection materials along with integration schemes. The lab's objectives are to limit energy coming...

  12. Laser calibration of the ATLAS Tile Calorimeter

    CERN Document Server

    Di Gregorio, Giulia; The ATLAS collaboration

    2017-01-01

    High performance stability of the ATLAS Tile calorimeter is achieved with a set of calibration procedures. One step of the calibrtion procedure is based on measurements of the response stability to laser excitation of the photomultipliers (PMTs) that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the test in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the resonse drifts seen with the PMT mounted on the Tile calorimeter in its normal operation during LHC run I and run II. A new statistical approach was developed to measure the drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to the data collected in the Pisa local laboratory. The preliminary results from these two studies are shown.

  13. Laser Calibration of the ATLAS Tile Calorimeter

    CERN Document Server

    Di Gregorio, Giulia; The ATLAS collaboration

    2017-01-01

    High performance stability of the ATLAS Tile Calorimeter is achieved with a set of calibration procedures. One step of the calibration procedure is based on measurements of the response stability to laser excitation of the PMTs that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the response drifts seen with the PMT mounted on the Tile calorimeter in its normal operating during LHC run I and run II. A new statistical approach was developed to measure drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to data collected in the Pisa local laboratory. The preliminary results from these two studies are shown.

  14. High power multiple wavelength diode laser stack for DPSSL application without temperature control

    Science.gov (United States)

    Hou, Dong; Yin, Xia; Wang, Jingwei; Chen, Shi; Zhan, Yun; Li, Xiaoning; Fan, Yingmin; Liu, Xingsheng

    2018-02-01

    High power diode laser stack is widely used in pumping solid-state laser for years. Normally an integrated temperature control module is required for stabilizing the output power of solid-state laser, as the output power of the solid-state laser highly depends on the emission wavelength and the wavelength shift of diode lasers according to the temperature changes. However the temperature control module is inconvenient for this application, due to its large dimension, high electric power consumption and extra adding a complicated controlling system. Furthermore, it takes dozens of seconds to stabilize the output power when the laser system is turned on. In this work, a compact hard soldered high power conduction cooled diode laser stack with multiple wavelengths is developed for stabilizing the output power of solid-state laser in a certain temperature range. The stack consists of 5 laser bars with the pitch of 0.43mm. The peak output power of each bar in the diode laser stack reaches as much as 557W and the combined lasing wavelength spectrum profile spans 15nm. The solidstate laser, structured with multiple wavelength diode laser stacks, allows the ambient temperature change of 65°C without suddenly degrading the optical performance.

  15. Fundamental Laser Welding Process Investigations

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    1998-01-01

    In a number of systematic laboratory investigations the fundamental behavior of the laser welding process was analyzed by the use of normal video (30 Hz), high speed video (100 and 400 Hz) and photo diodes. Sensors were positioned to monitor the welding process from both the top side and the rear...... side of the specimen.Special attention has been given to the dynamic nature of the laser welding process, especially during unstable welding conditions. In one series of experiments, the stability of the process has been varied by changing the gap distance in lap welding. In another series...... video pictures (400 Hz), a clear impact on the seam characteristics has been identified when a hump occurs.Finally, a clear correlation between the position of the focus point, the resultant process type and the corresponding signal intensity and signal variation has been found for sheets welded...

  16. Fundamental Laser Welding Process Investigations

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    1998-01-01

    In a number of systematic laboratory investigations the fundamental behavior of the laser welding process was analyzed by the use of normal video (30 Hz), high speed video (100 and 400 Hz) and photo diodes. Sensors were positioned to monitor the welding process from both the top side and the rear...... side of the specimen.Special attention has been given to the dynamic nature of the laser welding process, especially during unstable welding conditions. In one series of experiments, the stability of the process has been varied by changing the gap distance in lap welding. In another series...... of normal video and high speed video (100 Hz) can not reveal any instability in the process when humping occurs. Contrary to this, photo diode signals (sampled at 3 kHz) clearly indicate a characteristic signal when humps occur.When the seam area and seam width have manually been measured on high speed...

  17. FY 2005 Quantum Cascade Laser Alignment System Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Myers, Tanya L.; Cannon, Bret D.; Wojcik, Michael D.; Broocks, Bryan T.; Stewart, Timothy L.; Hatchell, Brian K.

    2006-01-11

    The Alignment Lasers Task of Pacific Northwest National Laboratory's (PNNL's) Remote Spectroscopy Project (Project PL211I) is a co-funded project between DOE NA-22 and a Classified Client. This project, which began in the second half of FY03, involved building and delivering a Quantum Cascade (QC) Laser Alignment System to be used for testing the pupil alignment of an infrared sensor by measuring the response from four pairs of diametrically opposed QC lasers. PNNL delivered the system in FY04 and provided technical assistance in FY05 culminating into a successful demonstration of the system. This project evolved from the Laser Development Task of PL211I, which is involved in developing novel laser technology to support development of advanced chemical sensors for detecting the proliferation of nuclear weapons. The laser systems are based on quantum cascade (QC) lasers, a new semiconductor source in the infrared. QC lasers can be tailored to emit light throughout the infrared region (3.5 ? 17 ?m) and have high output power and stability. Thus, these lasers provide an infrared source with superb power and spectral stability enabling them to be used for applications such as alignment and calibration in addition to chemical sensing.

  18. Laser technology (selected articles)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-09

    This paper presents high-energy CW HF/DF chemical lasers developed under the U.S. Navy Sealite program and the Alpha program of the DARPA Triad program, and a brief account of Soviet chemical lasers. Continuous wave HF/DF chemical lasers were developed starting in the late sixties as high-power lasers of consistent interest to military circles. These are lasers that have the most matured technology among present-day high-energy lasers. It is hoped that in the near future CW HF/DF chemical lasers can be developed into a space laser weapon to deal with ICBMs. CW HF/DF chemical lasers are an integration of technologies in gas dynamics, chemistry, fluid chemistry, optics, and lasers. By using the branching chain reaction of heat liberation, inversion of the population ratio is generated to obtain lasers.

  19. The Geoscience Laser Altimeter System Laser Transmitter

    Science.gov (United States)

    Afzal, R. S.; Dallas, J. L.; Yu, A. W.; Mamakos, W. A.; Lukemire, A.; Schroeder, B.; Malak, A.

    2000-01-01

    The Geoscience Laser Altimeter System (GLAS), scheduled to launch in 2001, is a laser altimeter and lidar for tile Earth Observing System's (EOS) ICESat mission. The laser transmitter requirements, design and qualification test results for this space- based remote sensing instrument are presented.

  20. Frequency stability measurement of pulsed superradiance from strontium

    Science.gov (United States)

    Norcia, Matthew; Cline, Julia; Robinson, John; Ye, Jun; Thompson, James

    2017-04-01

    Superradiant laser light from an ultra-narrow optical transition holds promise as a next-generation of active frequency references. We have recently demonstrated pulsed lasing on the milliHertz linewidth clock transition in strontium. Here, we present the first frequency comparisons between such a superradiant source and a state of the art stable laser system. We characterize the stability of the superradiant system, and demonstrate a reduction in sensitivity to cavity frequency fluctuations of nearly five orders of magnitude compared to a conventional laser. DARPA QUASAR, NIST, NSF PFC.

  1. Phase noise characterization of sub-hertz linewidth lasers via digital cross correlation.

    Science.gov (United States)

    Xie, Xiaopeng; Bouchand, Romain; Nicolodi, Daniele; Lours, Michel; Alexandre, Christophe; Le Coq, Yann

    2017-04-01

    Phase noise or frequency noise is a key metric to evaluate the short-term stability of a laser. This property is of great interest for the applications but delicate to characterize, especially for narrow linewidth lasers. In this Letter, we demonstrate a digital cross-correlation scheme to characterize the absolute phase noise of sub-hertz linewidth lasers. Three 1542 nm ultra-stable lasers are used in this approach. For each measurement, two lasers act as references to characterize a third one. Phase noise power spectral density from 0.5 Hz to 0.8 MHz Fourier frequencies can be derived for each laser by a mere change in the configuration of the lasers. To the best of our knowledge, this is the first time showing the phase noise of sub-hertz linewidth lasers with no reference limitation. We also present an analysis of the laser phase noise performance.

  2. Laser-based coatings removal

    International Nuclear Information System (INIS)

    Freiwald, J.G.; Freiwald, D.A.

    1995-01-01

    Over the years as building and equipment surfaces became contaminated with low levels of uranium or plutonium dust, coats of paint were applied to stabilize the contaminants in place. Most of the earlier paint used was lead-based paint. More recently, various non-lead-based paints, such as two-part epoxy, are used. For D ampersand D (decontamination and decommissioning), it is desirable to remove the paints or other coatings rather than having to tear down and dispose of the entire building. This report describes the use of pulse-repetetion laser systems for the removal of paints and coatings

  3. Laser safety and practice

    International Nuclear Information System (INIS)

    Low, K.S.

    1995-01-01

    Lasers are finding increasing routine applications in many areas of science, medicine and industry. Though laser radiation is non-ionizing in nature, the usage of high power lasers requires specific safety procedures. This paper briefly outlines the properties of laser beams and various safety procedures necessary in their handling and usage. (author)

  4. Visible Solid State Lasers

    NARCIS (Netherlands)

    Hikmet, R.A.M.

    2007-01-01

    Diode lasers can be found in various applications most notably in optical communication and optical storage. Visible lasers were until recently were all based on IR diode lasers. Using GaN, directly blue and violet emitting lasers have also been introduced to the market mainly in the area of optical

  5. Laser cladding with powder

    NARCIS (Netherlands)

    Schneider, M.F.; Schneider, Marcel Fredrik

    1998-01-01

    This thesis is directed to laser cladding with powder and a CO2 laser as heat source. The laser beam intensity profile turned out to be an important pa6 Summary rameter in laser cladding. A numerical model was developed that allows the prediction of the surface temperature distribution that is

  6. Laser EXAFS

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Schwenzel, R.E.; Campbell, B.E.

    1983-01-01

    Apparatus for obtaining EXAFS data of a material, comprising means for directing radiant energy from a laser onto a target in such manner as to produce X-rays at the target of a selected spectrum and intensity, suitable for obtaining the EXAFS spectrum of the material, means for directing X-rays from the target onto spectral dispersive means so located as to direct the spectrally resolved X-rays therefrom onto recording means, and means for positioning a sample of material in the optical path of the X-rays, the recording means providing a reference spectrum of X-rays not affected by the sample and absorption spectrum of X-rays modified by transmission through the sample

  7. Laser Microdissection.

    Science.gov (United States)

    Frost, Andra R; Eltoum, Isam-Eldin; Siegal, Gene P; Emmert-Buck, Michael R; Tangrea, Michael A

    2015-10-01

    Laser microdissection (LM) offers a relatively rapid and precise method of isolating and removing specified cells from complex tissues for subsequent analysis of their RNA, DNA, protein or metabolite content, thereby allowing assessment of the role of different cell types in the normal physiological or disease processes being studied. In this unit, protocols for the preparation of mammalian frozen tissues, fixed tissues, and cytologic specimens for LM, including tissue freezing, tissue processing and paraffin embedding, histologic sectioning, cell processing, hematoxylin and eosin staining, immunohistochemistry, and image-guided cell targeting are presented. Also provided are recipes for generating lysis buffers for the recovery of nucleic acids and proteins. The Commentary section addresses the types of specimens that can be utilized for LM and approaches to staining of specimens for cell visualization. Emphasis is placed on the preparation of tissue or cytologic specimens as this is critical to effective LM. Copyright © 2015 John Wiley & Sons, Inc.

  8. Current military laser applications

    Energy Technology Data Exchange (ETDEWEB)

    Flinchbaugh, D.E.

    1975-08-01

    Several important military applications with the predominant laser type used are reviewed. Most of these lasers are infrared lasers of one sort or another. Airborne tactical programs utilizing laser designator/illuminators are pictorially summarized, including range finding, target seeking, designation, tracking, reconnaissance, and surveillance. A typical designator optical system configuration is presented and discussed. Examples of operational laser systems are given. It is seen that many of the laser applications in the civilian community have either direct or indirect analogs in the military field. A self-contained HF/DF chemical laser weapon that recirculates its by-products is examined.

  9. Dynamics of a self-Q-switched fiber laser with a Rayleigh-stimulated Brillouin scattering ring mirror

    Science.gov (United States)

    Fotiadi, Andrei A.; Mégret, Patrice; Blondel, Michel

    2004-05-01

    Backward light scattering can cause passive Q switching in fiber lasers. We propose a self-consistent description of the laser dynamics. Our model quantitatively reproduces the temporal structure of pulsation and is also attractive for analysis of laser stability and statistics. The validity of the model is directly verified in an experiment.

  10. Multibeam Fibre Laser Cutting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove

    -laser cutting have until now limited its application in metal cutting. In this paper the first results of proof-of-principle studies applying a new approach (patent pending) for laser cutting with high brightness short wavelength lasers will be presented. In the approach, multi beam patterns are applied...... to control the melt flow out of the cut kerf resulting in improved cut quality in metal cutting. The beam patterns in this study are created by splitting up beams from 2 single mode fibre lasers and combining these beams into a pattern in the cut kerf. The results are obtained with a total of 550 W of single......The appearance of the high power high brilliance fibre laser has opened for new possibilities in laser materials processing. In laser cutting this laser has demonstrated high cutting performance compared to the dominating cutting laser, the CO2-laser. However, quality problems in fibre...

  11. A miniature frequency-stabilized VCSEL system emitting at 795 nm based on LTCC modules

    Science.gov (United States)

    Gruet, Florian; Vecchio, Fabrizio; Affolderbach, Christoph; Pétremand, Yves; de Rooij, Nico F.; Maeder, Thomas; Mileti, Gaetano

    2013-08-01

    We present a compact frequency-stabilized laser system locked to the Rubidium absorption line of a micro-fabricated reference cell. A printed circuit board (PCB) is used to carry all the components and part of the electronics, and low-temperature co-fired ceramic (LTCC) modules are used to temperature-stabilize the laser diode and the miniature Rubidium cell (cell inner dimensions: 5 mm diameter and 2 mm height). The measured frequency stability of the laser, in terms of Allan deviation, is ≤8×10-10 for integration times of 103-105s. The current overall dimensions of the system are 70×40×50 mm3, with good potential for realization of a frequency-stabilized laser module with few cm3 volume.

  12. Observation of wave packet dichotomy and adiabatic stabilization in an optical waveguide

    International Nuclear Information System (INIS)

    Longhi, S.; Marangoni, M.; Janner, D.; Ramponi, R.; Laporta, P.; Cianci, E.; Foglietti, V.

    2005-01-01

    We report on the first experimental observation of wave packet dichotomy and adiabatic stabilization of light in a periodically bent optical waveguide in analogy with similar behavior of atoms in high-frequency strong laser fields

  13. 303 nm continuous wave ultraviolet laser generated by intracavity frequency-doubling of diode-pumped Pr3+:LiYF4 laser

    Science.gov (United States)

    Zhu, Pengfei; Zhang, Chaomin; Zhu, Kun; Ping, Yunxia; Song, Pei; Sun, Xiaohui; Wang, Fuxin; Yao, Yi

    2018-03-01

    We demonstrate an efficient and compact ultraviolet laser at 303 nm generated by intracavity frequency doubling of a continuous wave (CW) laser diode-pumped Pr3+:YLiF4 laser at 607 nm. A cesium lithium borate (CLBO) crystal, cut for critical type I phase matching at room temperature, is used for second-harmonic generation (SHG) of the fundamental laser. By using an InGaN laser diode array emitting at 444.3 nm with a maximum incident power of 10 W, as high as 68 mW of CW output power at 303 nm is achieved. The output power stability in 4 h is better than 2.85%. To the best of our knowledge, this is high efficient UV laser generated by frequency doubling of an InGaN laser diode array pumped Pr3+:YLiF4 laser.

  14. Frequency locking of compact laser-diode modules at 633 nm

    Science.gov (United States)

    Nölleke, Christian; Leisching, Patrick; Blume, Gunnar; Jedrzejczyk, Daniel; Pohl, Johannes; Feise, David; Sahm, Alexander; Paschke, Katrin

    2018-02-01

    This work reports on a compact diode-laser module emitting at 633 nm. The emission frequency can be tuned with temperature and current, while optical feedback of an internal DBR grating ensures single-mode operation. The laser diode is integrated into a micro-fabricated package, which includes optics for beam shaping, a miniaturized optical isolator, and a vapor cell as frequency reference. The achieved absolute frequency stability is below 10-8 , while the output power can be more than 10 mW. This compact absolute frequency-stabilized laser system can replace gas lasers and may be integrated in future quantum technology devices.

  15. Laser ablation principles and applications

    CERN Document Server

    1994-01-01

    Laser Ablation provides a broad picture of the current understanding of laser ablation and its many applications, from the views of key contributors to the field. Discussed are in detail the electronic processes in laser ablation of semiconductors and insulators, the post-ionization of laser-desorbed biomolecules, Fourier-transform mass spectroscopy, the interaction of laser radiation with organic polymers, laser ablation and optical surface damage, laser desorption/ablation with laser detection, and laser ablation of superconducting thin films.

  16. Laser fusion research with GEKKO XII and PW laser system at Osaka

    International Nuclear Information System (INIS)

    Izawa, Y.; Mima, K.; Azechi, H.; Fujioka, S.; Fujita, H.; Fujimoto, Y.; Jitsuno, T.; Johzaki, Y.; Kitagawa, Y.; Kodama, R.; Kondo, K.; Miyanaga, N.; Nagai, K.; Nagatomo, H.; Nakai, M.; Nishihara, K.; Nishimura, H.; Norimatsu, T.; Shiraga, H.; Shigemori, K.; Sunahara, A.; Tanaka, K.A.; Tsubakimoto, K.; Nakao, Y.; Norreys, P.; Sakagami, H.

    2005-01-01

    Fast heating of the compressed core plasma up to 500eV has been successfully demonstrated by injecting a 400J/0.6ps PW laser into a compressed CD shell through a hollow gold cone. According to this result, we started the FIREX (Fast Ignition Realization Experiment) project toward demonstrating the ignition of the highly compressed DT fuel by the high energy PW laser heating. A new heating laser LFEX (Laser for Fast Ignition Experiment) is under construction. In this paper the progresses in the experimental studies on scientific issues related to fast ignition and the integrated code development toward the FIREX will be reported. Research results on implosion hydrodynamics, Rayleigh-Taylor instability growth and a new stabilization mechanism are also reported. (author)

  17. Technology of discharge and laser resonators for high power CO2 lasers. Koshutsuryoku CO2 laser ni tsukawareru hoden reiki laser kyoshinki gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Y.; Kuzumoto, M. (Mitsubishi Electric Corp., Tokyo (Japan))

    1994-03-20

    This paper describes discharge excitation technology and resonator technology as basic technologies for high power CO2 lasers. As a result of progress in high-frequency power element techniques, the discharge excitation technology now generally uses laser excitation using AC discharge of capacity coupling type. Its representative example is silent discharge (SD) excitation. This is a system to excite laser by applying high voltages with as high frequency as 100 kHz to 1 MHz across a pair of electrodes covered with a dielectric material. The system maintains stability in discharge even if power supply voltage amplitude is modulated, and easily provides pulse outputs. Discharge excitation for diffusion cooled type CO2 laser generates a discharge in a gap with a gap length of about 2 mm, and can perform gas cooling by means of thermal conduction of gas, whereas a compact resonator can be fabricated. A resonator for the diffusion cooled type CO2 laser eliminates gas circulation and cooling systems, hence the device can be made more compact. A report has been given that several of these compact resonators were combined, from which a laser output of 85W was obtained by using RF discharge of 2kW. 43 refs., 21 figs.

  18. Infrared laser system

    Science.gov (United States)

    Cantrell, Cyrus D.; Carbone, Robert J.; Cooper, Ralph S.

    1977-01-01

    An infrared laser system and method for isotope separation may comprise a molecular gas laser oscillator to produce a laser beam at a first wavelength, Raman spin flip means for shifting the laser to a second wavelength, a molecular gas laser amplifier to amplify said second wavelength laser beam to high power, and optical means for directing the second wavelength, high power laser beam against a desired isotope for selective excitation thereof in a mixture with other isotopes. The optical means may include a medium which shifts the second wavelength high power laser beam to a third wavelength, high power laser beam at a wavelength coincidental with a corresponding vibrational state of said isotope and which is different from vibrational states of other isotopes in the gas mixture.

  19. Laser-surface interactions

    CERN Document Server

    Ganeev, Rashid A

    2014-01-01

    This book is about the interaction of laser radiation with various surfaces at variable parameters of radiation. As a basic principle of classification we chose the energetic or intensity level of interaction of laser radiation with the surfaces. These two characteristics of laser radiation are the most important parameters defining entire spectrum of the processes occurring on the surfaces during interaction with electromagnetic waves. This is a first book containing a whole spectrum of the laser-surface interactions distinguished by the ranges of used laser intensity. It combines the surface response starting from extremely weak laser intensities (~1 W cm-2) up to the relativistic intensities (~1020 W cm-2 and higher). The book provides the basic information about lasers and acquaints the reader with both common applications of laser-surface interactions (laser-related printers, scanners, barcode readers, discs, material processing, military, holography, medicine, etc) and unusual uses of the processes on t...

  20. Infrared laser system

    International Nuclear Information System (INIS)

    Cantrell, C.D.; Carbone, R.J.

    1977-01-01

    An infrared laser system and method for isotope separation may comprise a molecular gas laser oscillator to produce a laser beam at a first wavelength, Raman spin flip means for shifting the laser to a second wavelength, a molecular gas laser amplifier to amplify said second wavelength laser beam to high power, and optical means for directing the second wavelength, high power laser beam against a desired isotope for selective excitation thereof in a mixture with other isotopes. The optical means may include a medium which shifts the second wavelength high power laser beam to a third wavelength, high power laser beam at a wavelength coincidental with a corresponding vibrational state of said isotope and which is different from vibrational states of other isotopes in the gas mixture

  1. Ceramic Laser Materials

    Science.gov (United States)

    Sanghera, Jasbinder; Kim, Woohong; Villalobos, Guillermo; Shaw, Brandon; Baker, Colin; Frantz, Jesse; Sadowski, Bryan; Aggarwal, Ishwar

    2012-01-01

    Ceramic laser materials have come a long way since the first demonstration of lasing in 1964. Improvements in powder synthesis and ceramic sintering as well as novel ideas have led to notable achievements. These include the first Nd:yttrium aluminum garnet (YAG) ceramic laser in 1995, breaking the 1 KW mark in 2002 and then the remarkable demonstration of more than 100 KW output power from a YAG ceramic laser system in 2009. Additional developments have included highly doped microchip lasers, ultrashort pulse lasers, novel materials such as sesquioxides, fluoride ceramic lasers, selenide ceramic lasers in the 2 to 3 μm region, composite ceramic lasers for better thermal management, and single crystal lasers derived from polycrystalline ceramics. This paper highlights some of these notable achievements. PMID:28817044

  2. Raman fiber lasers

    CERN Document Server

    2017-01-01

    This book serves as a comprehensive, up-to-date reference about this cutting-edge laser technology and its many new and interesting developments. Various aspects and trends of Raman fiber lasers are described in detail by experts in their fields. Raman fiber lasers have progressed quickly in the past decade, and have emerged as a versatile laser technology for generating high power light sources covering a spectral range from visible to mid-infrared. The technology is already being applied in the fields of telecommunication, astronomy, cold atom physics, laser spectroscopy, environmental sensing, and laser medicine. This book covers various topics relating to Raman fiber laser research, including power scaling, cladding and diode pumping, cascade Raman shifting, single frequency operation and power amplification, mid-infrared laser generation, specialty optical fibers, and random distributed feedback Raman fiber lasers. The book will appeal to scientists, students, and technicians seeking to understand the re...

  3. Laser resonators with several mirrors and lenses with the bow-tie laser resonator with compensation for astigmatism and thermal lens enects as an example

    DEFF Research Database (Denmark)

    Abitan, Haim; Skettrup, Torben

    2005-01-01

    Laser resonators with several mirrors (lenses) have been investigated in a systematic fashion. They have been grouped into classes according to their number n of mirrors/lenses. Stability polynomials, beam waist radii and locations have been obtained for each group up to n = 4. The bow-tie laser...

  4. Design of pulsed laser diode drive power for ZY3(02) laser altimeter

    Science.gov (United States)

    Feng, Wen; Li, Mingshan; Meng, Peibei; Yan, Fanjiang; Li, Xu; Wang, Chunhui

    2017-11-01

    Solid laser pumped by semiconductor laser has the large value in the area of space laser technology, because of the advantages of high efficiency, small volume and long life. As the indispensable component of laser, laser power is also very important. Combined with ZY3(02) laser altimeter project, a high voltage(0-300V), high current(0-80A), long pulse width(0-230us) and high precision temperature semiconductor laser power is developed. IGBT is applied in the driving circuit as the switch to provide a current pulse for LD. The heating or cooling capacity of TEC is controlled by PID compensation circuit quickly adjusts the duty cycle of the UC1637 PWM signal, to realize the high accuracy controlling of LD working temperature. The tests in the external ambient temperature of 5°C, 20°C, 30°C show that the LD current pulse is stable and the stability of LD working temperature up to +/-0.1°C around the set point temperature, which ensure the highly stable operation of DPL.

  5. Laser cooling of solids

    OpenAIRE

    Nemova, Galina

    2009-01-01

    Parallel to advances in laser cooling of atoms and ions in dilute gas phase, which has progressed immensely, resulting in physics Nobel prizes in 1997 and 2001, major progress has recently been made in laser cooling of solids. I compare the physical nature of the laser cooling of atoms and ions with that of the laser cooling of solids. I point out all advantages of this new and very promising area of laser physics. Laser cooling of solids (optical refrigeration) at the present time can be lar...

  6. Excimer laser applications

    International Nuclear Information System (INIS)

    Fantoni, R.

    1988-01-01

    This lecture deals with laser induced material photoprocessing, especially concerning those processes which are initiated by u.v. lasers (mostly excimer laser). Advantages of using the u.v. radiation emitted by excimer lasers, both in photophysical and photochemical processes of different materials, are discussed in detail. Applications concerning microelectronics are stressed with respect to other applications in different fields (organic chemistry, medicine). As further applications of excimer lasers, main spectroscopic techniques for ''on line'' diagnostics which employ excimer pumped dye lasers, emitting tunable radiation in the visible and near u.v. are reviewed

  7. Lasers in ophthalmology.

    Science.gov (United States)

    Gilmour, Margi A

    2002-05-01

    Laser technology continues to progress with the addition of new lasers, new delivery systems, and new applications. The introduction of lasers to veterinary ophthalmology has radically changed the level of care that we can provide to our patients. The development of the diode laser has particularly had an impact on veterinary ophthalmology. The diode's affordability, portability, and broad applications for veterinary patients have allowed laser surgery to become a routine part of veterinary ophthalmology practice. Educating the public and veterinary community in available laser techniques will generate improved ophthalmic care and provide more data on which to build future applications.

  8. Phospholipid stabilized gold nanorods: towards improved colloidal stability and biocompatibility.

    Science.gov (United States)

    Santhosh, Poornima Budime; Thomas, Neethu; Sudhakar, Swathi; Chadha, Anju; Mani, Ethayaraja

    2017-07-19

    Biocompatible and colloidally stable gold nanorods (GNRs) with well-defined plasmonic properties are essential for biomedical and theranostic applications. The as-synthesized GNRs using the seed-mediated method are stabilized by the surfactant, cetyltrimethylammonium bromide (CTAB), which is known for its cytotoxicity in many cell lines. Biocompatible GNRs synthesized using known protocols exhibit some extent of cytotoxicity and colloidal instability because of the incomplete removal of CTAB. We report a facile method for the efficient removal of CTAB molecules with 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) phospholipid molecules, which are naturally present in cell membranes. The kinetics of the ligand exchange process is studied using surface-enhanced Raman scattering (SERS) and corroborated with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. From colloidal stability studies using dynamic light scattering (DLS) and UV-Vis spectroscopy, the optimal lipid concentration and duration required for the successful ligand exchange of CTAB by DMPC are reported. Using thermogravimetric analysis, the surface concentration of DMPC on colloidally stable GNRs is found to be approximately 9 molecules per nm 2 . The 3-(4,5-dimethylthiozol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) and lactate dehydrogenase (LDH) assays show that the surface-modified DMPC-GNRs have significantly better biocompatibility than those of CTAB-GNRs. Studies on the ligand exchange, colloidal stability and biocompatibility of DMPC-GNRs with aspect ratios ranging from 2.2 to 4.2 demonstrate the robustness of the proposed method. The results provide insights into the important factors to be considered while designing biocompatible GNRs suitable for applications in nanomedicine.

  9. The laser-based calibration system of delta spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Malakhov, A.I. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Anisimov, Yu.S. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Gmuca, S. [Inst. of Physics, SAS, Bratislava (Slovakia); Kizka, V.A. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Kliman, J. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Inst. of Physics, SAS, Bratislava (Slovakia); Krasnov, V.A. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Kurepin, A.B. [Inst. for Nuclear Research RAS, Moscow (Russian Federation); Kuznetsov, S.N. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Livanov, A.N. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Matousek, V. [Inst. of Physics, SAS, Bratislava (Slovakia); Morhac, M. [Inst. of Physics, SAS, Bratislava (Slovakia)]. E-mail: Miroslav.Morhac@savba.sk; Turzo, I. [Inst. of Physics, SAS, Bratislava (Slovakia)

    2006-10-15

    We present a report on a laser calibration system of DELTA spectrometer that has been designed and developed in the Laboratory of High Energies, JINR, Dubna. The system is intended for monitoring and continuous stabilization of the outputs of the detectors of the spectrometer. The UV nitrogen pulse laser along with optical filters, collection of optical fibers and plastic scintillators serving for conversion of UV light pulses to longer wavelength and for diffusion of the light beam to illuminate 300 photomultipliers are used. We stabilize the positions of laser peaks by corrections of high voltages of the corresponding photomultipliers. The proposed system allows one to accomplish the stabilization during the experiment with the use of the same electronics. The control software together with the first results from test runs are described as well.

  10. Stability of parallel flows

    CERN Document Server

    Betchov, R

    2012-01-01

    Stability of Parallel Flows provides information pertinent to hydrodynamical stability. This book explores the stability problems that occur in various fields, including electronics, mechanics, oceanography, administration, economics, as well as naval and aeronautical engineering. Organized into two parts encompassing 10 chapters, this book starts with an overview of the general equations of a two-dimensional incompressible flow. This text then explores the stability of a laminar boundary layer and presents the equation of the inviscid approximation. Other chapters present the general equation

  11. Laser materials processing with diode lasers

    OpenAIRE

    Li, Lin; Lawrence, Jonathan; Spencer, Julian T.

    1996-01-01

    Laser materials processing is currently dominated by CO2, Nd-YAG and Excimer lasers. Continuous advances in semiconductor laser technology over the last decade have increased the average power output of the devices annualy by two fold, resulting in the commercial availability of the diode lasers today with delivery output powers in excess of 60W in CW mode and 5kW in qasi-CW mode. The advantages of compactness, high reliability, high efficiency and potential low cost, due to the mass producti...

  12. 1982 laser program annual report

    International Nuclear Information System (INIS)

    Hendricks, C.D.; Grow, G.R.

    1983-08-01

    This annual report covers the following eight sections: (1) laser program review, (2) laser systems and operation, (3) target design, (4) target fabrication, (5) fusion experiments program, (6) Zeus laser project, (7) laser research and development, and (8) energy applications

  13. A fast 8-channel wavelength switching DFB diode laser array based on reconstruction-equivalent-chirp technique

    Science.gov (United States)

    Li, Wei; Wang, Yingying; Du, Yinchao; Du, Weikang; Zhao, Guowang; Fang, Tao

    2018-01-01

    We propose a new method to investigate fast wavelength switching, which consists of control circuit, driving circuit and 8-channel DFB laser array using reconstruction-equivalent-chirp technique. The control circuit is in charge of selecting required lasers to switch wavelength, the driving circuit supply adjustable and stable direct current to the DFB laser arrays. Experimental results show that wavelength switching time of 8 channels is about 500ns and stability of laser output is promised.

  14. An alternative method to specify the degree of resonator stability

    Indian Academy of Sciences (India)

    maximum value of the degree of stability corresponding to S = 100%, automatically corresponds to g1g2 = 1/2. We also describe an experimental technique to measure the S parameter from the laser output beam characteristics and B parameter. The measured value of S parameter is in close agreement with the predicted ...

  15. The shipboard employment of a free electron laser weapon system

    OpenAIRE

    Allgaier, Gregory G.

    2003-01-01

    Approved for Public Release; Distribution is Unlimited A megawatt (MW) class Free Electron Laser (FEL) shows promise as a new weapon for antiship cruise missile defense. An FEL weapon system delivers energy at the speed of light at controllable energy levels, giving the war fighter new engagement options. Considerations for this weapon system include employment, design, and stability. In order to reach a MW class laser, system parameters must be optimized and the high power optical beam mu...

  16. Tunable single and dual mode operation of an external cavity quantum-dot injection laser

    Energy Technology Data Exchange (ETDEWEB)

    Biebersdorf, A [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Lingk, C [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); De Giorgi, M [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Feldmann, J [Photonics and Optoelectronics Group, Physics Department and CeNS, Ludwig-Maximilians-Universitaet, Amalienstrasse 54, D-80799 Munich (Germany); Sacher, J [Sacher Lasertechnik GmbH, Hannah Arendt Strasse 3-7, D-35037 Marburg (Germany); Arzberger, M [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Ulbrich, C [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Boehm, G [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Amann, M-C [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Abstreiter, G [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany)

    2003-08-21

    We investigate quantum-dot (QD) lasers in an external cavity using Littrow and Littman configurations. Here, we report on a continuously tunable QD laser with a broad tuning range from 1047 to 1130 nm with high stability and efficient side mode suppression. The full-width at half-maximum of the laser line is 0.85 nm determined mainly by the quality of the external grating. This laser can be operated in a dual-mode modus, where the mode-spacing can be tuned continuously between 1.1 and 34 nm. Simultaneous emission of the two laser modes is shown by sum frequency generation experiments.

  17. A proposed high-power UV industrial demonstration laser at CEBAF

    International Nuclear Information System (INIS)

    Benson, S.V.; Bisognano, J.J.; Bohn, C.L.

    1996-01-01

    The Laser Processing Consortium, a collaboration of industries, universities, and the Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, Virginia, has proposed building a demonstration industrial processing laser for surface treatment and micro-machining. The laser is a free-electron laser (FEL) with average power output exceeding 1 kW in the ultraviolet (UV). The design calls for a novel driver accelerator that recovers most of the energy of the exhaust electron beam to produce laser light with good wall-plug efficiency. The laser and accelerator design use technologies that are scalable to much higher power. The authors will describe the critical design issues in the laser such as the stability, power handling, and losses of the optical resonator, and the quality, power, and reliability of the electron beam. They will also describe the calculated laser performance. Finally progress to date on accelerator development and resonator modeling will be reported

  18. A proposed high-power UV industrial demonstration laser at CEBAF

    International Nuclear Information System (INIS)

    Benson, S.V.; Bisognano, J.J.; Bohn, C.L.

    1996-01-01

    The Laser Processing Consortium, a collaboration of industries, universities, and the Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, Virginia, has proposed building a demonstration industrial processing laser for surface treatment and micro-machining. The laser is a free-electron laser (FEL) with average power output exceeding 1 kW in the ultraviolet (UV). The design calls for a novel driver accelerator that recovers most of the energy of the exhaust electron beam to produce laser light with good wall-plug efficiency. The laser and accelerator design use technologies that are scalable to much higher power. The authors describe the critical design issues in the laser such as the stability, power handling, and losses of the optical resonator, and the quality, power, and reliability of the electron beam. They also describe the calculated laser performance. Finally progress to date on accelerator development and resonator modeling will be reported

  19. Fiber laser master oscillators for optical synchronization systems

    International Nuclear Information System (INIS)

    Winter, A.

    2008-04-01

    New X-ray free electron lasers (e.g. the European XFEL) require a new generation of synchronization system to achieve a stability of the FEL pulse, such that pump-probe experiments can fully utilize the ultra-short pulse duration (50 fs). An optical synchronization system has been developed based on the distribution of sub-ps optical pulses in length-stabilized fiber links. The synchronization information is contained in the precise repetition frequency of the optical pulses. In this thesis, the design and characterization of the laser serving as laser master oscillator is presented. An erbium-doped mode-locked fiber laser was chosen. Amplitude and phase noise were measured and record-low values of 0.03 % and 10 fs for the frequency range of 1 kHz to the Nyquist frequency were obtained. Furthermore, an initial proof-of-principle experiment for the optical synchronization system was performed in an accelerator environment. In this experiment, the fiber laser wase phase-locked to a microwave reference oscillator and a 500 meter long fiber link was stabilized to 12 fs rms over a range of 0.1 Hz to 20 kHz. RF signals were obtained from a photodetector without significant degradation at the end of the link. Furthermore, the laser master oscillator for FLASH was designed and is presently in fabrication and the initial infrastructure for the optical synchronization system was setup. (orig.)

  20. Fiber laser master oscillators for optical synchronization systems

    Energy Technology Data Exchange (ETDEWEB)

    Winter, A.

    2008-04-15

    New X-ray free electron lasers (e.g. the European XFEL) require a new generation of synchronization system to achieve a stability of the FEL pulse, such that pump-probe experiments can fully utilize the ultra-short pulse duration (50 fs). An optical synchronization system has been developed based on the distribution of sub-ps optical pulses in length-stabilized fiber links. The synchronization information is contained in the precise repetition frequency of the optical pulses. In this thesis, the design and characterization of the laser serving as laser master oscillator is presented. An erbium-doped mode-locked fiber laser was chosen. Amplitude and phase noise were measured and record-low values of 0.03 % and 10 fs for the frequency range of 1 kHz to the Nyquist frequency were obtained. Furthermore, an initial proof-of-principle experiment for the optical synchronization system was performed in an accelerator environment. In this experiment, the fiber laser wase phase-locked to a microwave reference oscillator and a 500 meter long fiber link was stabilized to 12 fs rms over a range of 0.1 Hz to 20 kHz. RF signals were obtained from a photodetector without significant degradation at the end of the link. Furthermore, the laser master oscillator for FLASH was designed and is presently in fabrication and the initial infrastructure for the optical synchronization system was setup. (orig.)