  1. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  2. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  3. Acoustic Detection from Aerial Balloon Platform

    National Research Council Canada - National Science Library

    Reiff, C; Pham, T; Scanlon, M; Noble, J; Van Landuyt, A; Petek, J; Ratches, J

    2004-01-01

    ... such as unmanned aerial vehicles (UAVs) and balloons. Our most immediate collaboration focuses on the use of acoustic sensors on small balloons and/or aerostats at several elevations and on the ground with the primary goals...

  4. Detecting Seismic Infrasound Signals on Balloon Platforms

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M.; Garcia, R.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-12-01

    The determination of the interior structure of a planet requires detailed seismic investigations - a process that entails the detection and characterization of seismic waves due to geological activities (e.g., earthquakes, volcanoes, etc.). For decades, this task has primarily been performed on Earth by an ever-expanding network of terrestrial seismic stations. However, on planets such as Venus, where the surface pressure and temperature can reach as high as 90 atmospheres and 450 degrees Celsius respectively, placing seismometers on the planet's surface poses a vexing technological challenge. However, the upper layers of the Venusian atmosphere are more benign and capable of hosting geophysical payloads for longer mission lifetimes. In order to achieve the aim of performing geophysical experiments from an atmospheric platform, JPL and its partners (ISAE-SUPAERO and California Institute of Technology) are in the process of developing technologies for detection of infrasonic waves generated by earthquakes from a balloon. The coupling of seismic energy into the atmosphere critically depends on the density differential between the surface of the planet and the atmosphere. Therefore, the successful demonstration of this technique on Earth would provide ample reason to expect success on Venus, where the atmospheric impedance is approximately 60 times that of Earth. In this presentation, we will share results from the first set of Earth-based balloon experiments performed in Pahrump, Nevada in June 2017. These tests involved the generation of artificial sources of known intensity using a seismic hammer and their detection using a complex network of sensors, including highly sensitive micro-barometers suspended from balloons, GPS receivers, geophones, microphones, and seismometers. This experiment was the first of its kind and was successful in detecting infrasonic waves from the earthquakes generated by the seismic hammer. We will present the first comprehensive analysis

  5. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  6. Ideal ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Galvao, R.M.O.; Lazzaro, E.; O'Rourke, J.; Smeulders, P.; Schmidt, G.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, discharges with β approaching the Troyon-Sykes-Wesson critical value β c for optimised pressure profiles have been produced at low toroidal fields (B T =1.5T). In the second type, extremely high pressure gradients have been produced in the plasma core through pellet injection in the current rise phase of the discharge followed by strong additional heating. The stability of these discharges has been studied with the stability code HBT coupled to the equilibrium identification code IDENTC. The equilibrium pressure and diamagnetic function profiles are determined in IDENTC by an optimisation procedure to fit the external magnetic measurements. The resulting pressure profile in the equatorial plane is then compared with the profile derived from 'direct' measurements, i.e. electron density and temperature profiles measured by the LIDAR diagnostic system, ion-temperature profile measured by the charge-exchange diagnostic system, and ion density profile calculated from the Z eff and electron density profiles. Furthermore, the value of the safety factor q on axis is compared with that determined from polarimetry. When good agreement is found, the output data from IDENTC is passed directly to HBT to carry out the stability analysis. When there is not a good agreement, as in the case of pellet discharges with highly peaked pressure profiles, the equilibrium is reevaluated using the 'experimental' profile and the data from polarimetry. (author) 6 refs., 4 figs

  7. Planetary Balloon-Based Science Platform Evaluation and Program Implementation

    Science.gov (United States)

    Dankanich, John W.; Kremic, Tibor; Hibbitts, Karl; Young, Eliot F.; Landis, Rob

    2016-01-01

    This report describes a study evaluating the potential for a balloon-based optical telescope as a planetary science asset to achieve decadal class science. The study considered potential science achievable and science traceability relative to the most recent planetary science decadal survey, potential platform features, and demonstration flights in the evaluation process. Science Potential and Benefits: This study confirms the cost the-benefit value for planetary science purposes. Forty-four (44) important questions of the decadal survey are at least partially addressable through balloon based capabilities. Planetary science through balloon observations can provide significant science through observations in the 300 nm to 5 m range and at longer wavelengths as well. Additionally, balloon missions have demonstrated the ability to progress from concept to observation to publication much faster than a space mission increasing the speed of science return. Planetary science from a balloon-borne platform is a relatively low-cost approach to new science measurements. This is particularly relevant within a cost-constrained planetary science budget. Repeated flights further reduce the cost of the per unit science data. Such flights offer observing time at a very competitive cost. Another advantage for planetary scientists is that a dedicated asset could provide significant new viewing opportunities not possible from the ground and allow unprecedented access to observations that cannot be realized with the time allocation pressures faced by current observing assets. In addition, flight systems that have a relatively short life cycle and where hardware is generally recovered, are excellent opportunities to train early career scientists, engineers, and project managers. The fact that balloon-borne payloads, unlike space missions, are generally recovered offers an excellent tool to test and mature instruments and other space craft systems. Desired Gondola Features: Potential

  8. Ballooning Stability of the Compact Quasiaxially Symmetric Stellarator

    International Nuclear Information System (INIS)

    Redi, M.H.; Canik, J.; Dewar, R.L.; Johnson, J.L.; Klasky, S.; Cooper, W.A.; Kerbichler, W.

    2001-01-01

    The magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), expected to achieve good stability and particle confinement is examined with a method that can lead to estimates of global stability. Making use of fully 3D, ideal-MHD stability codes, the QAS beta is predicted to be limited above 4% by ballooning and high-n kink modes. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space [s, alpha, theta(subscript ''k'')]; s is the edge normalized toroidal flux, alpha is the field line variable, and theta(subscript ''k'') is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, with new types of nonsymmetric, eigenvalue isosurfaces in both the stable and unstable spectrum. The isosurfaces around the most unstable points i n parameter space (well above marginal) are topologically spherical. In such cases, attempts to use ray tracing to construct global ballooning modes lead to a k-space runaway. Introduction of a reflecting cutoff in k(perpendicular) to model numerical truncation or finite Larmor radius (FLR) yields chaotic ray paths ergodically filling the allowed phase space, indicating that the global spectrum must be described using the language of quantum chaos theory. However, the isosurface for marginal stability in the cases studied are found to have a more complex topology, making estimation of FLR stabilization more difficult

  9. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    Miller, R.L.; Waelbroeck, F.L.; Hassam, A.B.; Waltz, R.E.

    1995-01-01

    Stabilization of magnetohydrodynamic ballooning modes by sheared toroidal rotation is demonstrated using a shifted circle equilibrium model. A generalized ballooning mode representation is used to eliminate the fast Alfven wave, and an initial value code solves the resulting equations. The s-α diagram (magnetic shear versus pressure gradient) of ballooning mode theory is extended to include rotational shear. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and direct stable access to the second stability regime occurs when this frequency is approximately one-quarter to one-half the Alfven frequency, ω A =V A /qR. copyright 1995 American Institute of Physics

  10. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs

  11. Ideal ballooning stability near an equilibrium magnetic island

    Energy Technology Data Exchange (ETDEWEB)

    Hegna, C.C.; Callen, J.D.

    1992-03-01

    The stability properties of ideal ballooning modes on toroidal flux surfaces near a quasistatic magnetic island is examined. On these surfaces, magnetic field-line trajectories tend to bunch on that part of the magnetic surface closet to the X-point of the magnetic island. Because of this preferential bunching, the stabilizing effect of field-line bending due to magnetic shear can be reduced. Eigenfunctions localized in helical angle near the X-point and in poloidal angle on the bad curvature side of the tokamak are more susceptible to ballooning instability than are modes in corresponding equilibria without the magnetic island. For a slowly growing island, a growing number of flux surfaces located near the separatrix become ballooning unstable. Secondary ballooning instabilities may play a part in the crash phase of sawteeth or macroscopic island dynamics.

  12. Refractivity Turbulence Observation Using a New Balloon-Ring Platform (Preprint)

    National Research Council Canada - National Science Library

    Eaton, Frank D; Kelly, Patrick R; Kyrazis, Demos T; Stokes, Sheldon S

    2002-01-01

    This paper presents new methodology to address critical refractivity turbulence issues for laser propagation using a new measurement system-a portable "balloon-ring" platform with multiple fine wire...

  13. Asymptotic stability boundaries of ballooning modes in circular tokamaks

    International Nuclear Information System (INIS)

    Chen, L.; Bondeson, A.; Chance, M.S.

    1987-06-01

    The model ballooning mode equation of Connor, Hastie, and Taylor for large-aspect-ratio circular tokamaks is analyzed in the limit of large pressure gradient, and corresponding expressions for stability boundaries are derived. In particular, it is found that for a fixed radial wave number, there exists an infinite sequence of unstable bands, and that minimizing over the radial wave numbers leads to asymptotic merging between the neighboring bands

  14. Stability of Magnetic Equilibria in Radio Balloons

    OpenAIRE

    Benford, Gregory

    2006-01-01

    Current-carrying flows, in the laboratory and in astrophysical jets, can form remarkably stable magnetic structures. Decades of experience shows that such flows often build equilibria that reverse field directions, evolving to an MHD Taylor state, which has remarkable stability properties. We model jets and the magnetic bubbles they build as reversed field pinch equilibria by assuming the driver current to be stiff in the MHD sense. Taking the jet current as rigid and a fixed function of posi...

  15. Avionics and Power Management for Low-Cost High-Altitude Balloon Science Platforms

    Science.gov (United States)

    Chin, Jeffrey; Roberts, Anthony; McNatt, Jeremiah

    2016-01-01

    High-altitude balloons (HABs) have become popular as educational and scientific platforms for planetary research. This document outlines key components for missions where low cost and rapid development are desired. As an alternative to ground-based vacuum and thermal testing, these systems can be flight tested at comparable costs. Communication, solar, space, and atmospheric sensing experiments often require environments where ground level testing can be challenging or impossible in certain cases. When performing HAB research the ability to monitor the status of the platform and gather data is key for both scientific and recoverability aspects of the mission. A few turnkey platform solutions are outlined that leverage rapidly evolving open-source engineering ecosystems. Rather than building custom components from scratch, these recommendations attempt to maximize simplicity and cost of HAB platforms to make launches more accessible to everyone.

  16. Geometrical improvements of rotational stabilization of high-n ballooning modes in tokamaks

    International Nuclear Information System (INIS)

    Furukawa, Masaru; Tokuda, S.

    2003-01-01

    We have found numerically that damping phases appear in the time evolution of the perturbation energy of high-n ballooning modes in the presence of toroidal shear flows. The damping dominates exponential growth which occurs in the bad curvature region, resulting in stabilization of ballooning modes. D-shaping of plasma cross-section, reduction of aspect ratio, and arrangement of X-point at inner side of the torus enhance the stabilization effect of the toroidal flow through this mechanism. (author)

  17. A gimbal platform stabilization for topographic applications

    Energy Technology Data Exchange (ETDEWEB)

    Michele, Mangiameli, E-mail: michele.mangiameli@dica.unict.it; Giuseppe, Mussumeci [Dept. of Civil Engineering and Architecture, University of Catania, Catania (Italy)

    2015-03-10

    The aim of this work is the stabilization of a Gimbal platform for optical sensors acquisitions in topographic applications using mobile vehicles. The stabilization of the line of sight (LOS) consists in tracking the command velocity in presence of nonlinear noise due to the external environment. The hardware architecture is characterized by an Ardupilot platform that allows the control of both the mobile device and the Gimbal. Here we developed a new approach to stabilize the Gimbal platform, which is based on neural network. For the control system, we considered a plant that represents the transfer function of the servo system control model for an inertial stabilized Gimbal platform. The transductor used in the feed-back line control is characterized by the Rate Gyro transfer function installed onboard of Ardupilot. For the simulation and investigation of the system performance, we used the Simulink tool of Matlab. Results show that the hardware/software approach is efficient, reliable and cheap for direct photogrammetry, as well as for general purpose applications using mobile vehicles.

  18. Anderson localization of ballooning modes, quantum chaos and the stability of compact quasiaxially symmetric stellarators

    International Nuclear Information System (INIS)

    Redi, M.H.; Johnson, J.L.; Klasky, S.; Canik, J.; Dewar, R.L.; Cooper, W.A.

    2002-01-01

    The radially local magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), is examined just above the ballooning beta limit with a method that can lead to estimates of global stability. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space (s,α,θ k ); s is the edge normalized toroidal flux, α is the field line variable, and θ k is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, and gives rise to new types of nonsymmetric eigenvalue isosurfaces in both the stable and unstable spectrum. For eigenvalues far above the marginal point, isosurfaces are topologically spherical, indicative of strong 'quantum chaos'. The complexity of QAS marginal isosurfaces suggests that finite Larmor radius stabilization estimates will be difficult and that fully three-dimensional, high-n MHD computations are required to predict the beta limit

  19. Influence of Pressure-gradient and Shear on Ballooning Stability in Stellarators

    International Nuclear Information System (INIS)

    Hudson, S.R.; Hegna, C.C.; Nakajima, N.

    2005-01-01

    Pressure-driven, ideal ballooning stability calculations are often used to predict the achievable plasma in stellarator configurations. In this paper, the sensitivity of ballooning stability to plasmas profile variations is addressed. A simple, semi-analytic method for expressing the ballooning growth rate, for each field line, as a polynomial function of the variation in the pressure gradient and the average magnetic shear from an original equilibrium has recently been introduced [Phys. Plasmas 11:9 (September 2004) L53]. This paper will apply the expression to various stellarator configurations and comment on the validity of various truncated forms of the polynomial expression. In particular, it is shown that in general it is insufficient to consider only the second order terms as previously assumed, and that higher order terms must be included to obtain accurate predictions of stability

  20. Developments of Highly Multiplexed, Multi-chroic Pixels for Balloon-Borne Platforms

    Science.gov (United States)

    Aubin, F.; Hanany, S.; Johnson, B. R.; Lee, A.; Suzuki, A.; Westbrook, B.; Young, K.

    2018-02-01

    We present our work to develop and characterize low thermal conductance bolometers that are part of sinuous antenna multi-chroic pixels (SAMP). We use longer, thinner and meandered bolometer legs to achieve 9 pW/K thermal conductance bolometers. We also discuss the development of inductor-capacitor chips operated at 4 K to extend the multiplexing factor of the frequency domain multiplexing to 105, an increase of 60% compared to the factor currently demonstrated for this readout system. This technology development is motivated by EBEX-IDS, a balloon-borne polarimeter designed to characterize the polarization of foregrounds and to detect the primordial gravity waves through their B-mode signature on the polarization of the cosmic microwave background. EBEX-IDS will operate 20,562 transition edge sensor bolometers spread over 7 frequency bands between 150 and 360 GHz. Balloon and satellite platforms enable observations at frequencies inaccessible from the ground and with higher instantaneous sensitivity. This development improves the readiness of the SAMP and frequency domain readout technologies for future satellite applications.

  1. High-mode-number ballooning modes in a heliotron/torsatron system: 2, Stability

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, N.

    1996-05-01

    In heliotron/torsantron systems that have a large Shafranov shift, the local magnetic shear is found to have no stabilizing effect on high-mode-number ballooning modes at the outer side of the torus, even in the region where the global shear is stellarator-like in nature. The disappearance of this stabilization, in combination with the compression of the flux surfaces at the outer side of the torus, leads at relatively low values of the plasma pressure to significant modifications of the stabilizing effect due to magnetic field-line bending on high-mode-number ballooning modes-specifically, that the field-line bending stabilization can be remarkably suppressed or enhanced. In an equilibrium that is slightly Mercier-unstable or completely Mercier-stable due to peaked pressure profiles, such as those used in standaxd stability calculations or observed in experiments on the Compact Helical System, high-mode-number ballooning modes are destabilized due to these modified stability effects, with their eigenfunctions highly localized along the field line. Highly localized mode structures such as these cause the ballooning mode eigenvalues {omega} {sup 2} to have a strong field line dependence through the strong dependence of the local magnetic curvature, such that the level surfaces of {omega} {sup 2} ({psi}, {theta} {sub k}, {alpha}), (<0) become spheroids in ({theta} {sub k}, {alpha}) space, where {psi} labels flux surfaces and {theta} {sub k} is the radial wavenumber. Because the spheroidal level surfaces for unstable eigenvalues are surrounded by level surfaces for stable eigenvalues of high-mode-number toroidal Alfven eigenmodes, those high-mode-number ballooning modes never lead to low-mode-number modes. In configuration space, these high- mode-number modes are localized in a single toroidal pitch of the helical coils, and hence they may experience substantial stabilization due to finite Larmor radius effects.

  2. Global kink and ballooning modes in high-beta systems and stability of toroidal drift modes

    International Nuclear Information System (INIS)

    Galvao, R.M.O.; Goedbloed, J.P.; Rem, J.; Sakanaka, P.H.; Schep, T.J.; Venema, M.

    1983-01-01

    A numerical code (HBT) has been developed which solves for the equilibrium, global stability and high-n stability of plasmas with arbitrary cross-section. Various plasmas are analysed for their stability to these modes in the high-beta limit. Screw-pinch equilibria are stable to high-n ballooning modes up to betas of 18%. The eigenmode equation for drift waves is analysed numerically. The toroidal branch is shown to be destabilized by the non-adiabatic response of trapped and circulating particles. (author)

  3. Optical measurements of atmospheric particles from airborne platforms: in situ and remote sensing instruments for balloons and aircrafts

    Directory of Open Access Journals (Sweden)

    A. Adriani

    2006-06-01

    Full Text Available Multiwavelength laser backscattersondes (MAS have been widely used from a variety of airborne platforms for in situ measurements of optical properties of clouds and atmospheric particulate as well as their phase and composition. Recently, a new miniaturized LIDAR (MULID has been developed using state-of-art technology for balloon borne profiling of the same quantities. A description of the two instruments, a survey of preliminary results obtained during test flights and indications for future use are given.

  4. The advanced cosmic microwave explorer - A millimeter-wave telescope and stabilized platform

    Science.gov (United States)

    Meinhold, P. R.; Chingcuanco, A. O.; Gundersen, J. O.; Schuster, J. A.; Seiffert, M. D.; Lubin, P. M.; Morris, D.; Villela, T.

    1993-01-01

    We have developed and flown a 1 m diameter Gregorian telescope system for measurements of anisotropy in the Cosmic Background Radiation (CBR). The telescope is incorporated in a balloon-borne stabilized platform with arcminute stabilization capability. To date, the system has flown four times and observed from the ground at the South Pole twice. The telescope has used both coherent and incoherent detectors. We describe the development of the telescope, pointing platform, and one of the receivers employed in making measurements of the CBR. Performance of the system during the first flight and operation on the ground at the South Pole are described, and the quality of the South Pole as a millimeter wave observing site is discussed.

  5. Compressibility effects on ideal and kinetic ballooning modes and elimination of finite Larmor radius stabilization

    International Nuclear Information System (INIS)

    Kotschenreuther, M.

    1985-07-01

    The dynamics of ideal and kinetic ballooning modes are considered analytically including parallel ion dynamics, but without electron dissipation. For ideal modes, parallel dynamics predominantly determine the growth rate when β is within approx.30% of the ideal threshold, resulting in a substantial reduction in growth rate. Compressibility also eliminates the stabilization effects of finite Larmor radius (FLR); FLR effects (when temperature gradients are neglected) can even increase the growth rate above the MHD value. Temperature gradients accentuate this by adding a new source of free energy independent of the MHD drive, in this region of ballooning coordinate corresponding in MHD to the continuum. Analytic dispersion relations are derived demonstrating the effects above; the formalism emphasizes the similarities between the ideal MHD and kinetic cases

  6. Effects of ion temperature fluctuations on the stability of resistive ballooning modes

    International Nuclear Information System (INIS)

    Singh, R.; Nordman, H.; Jarmen, A.; Weiland, J.

    1996-01-01

    The influence of ion temperature fluctuations on the stability of resistive drift- and ballooning-modes is investigated using a two-fluid model. The Eigenmode equations are derived and solved analytically in a low beta model equilibrium. Parameters relevant to L-mode edge plasmas from the Texas Experimental Tokamak are used. The resistive modes are found to be destabilized by ion temperature fluctuations over a broad range of mode numbers. The scaling of the growth rate with magnetic shear and mode number is elucidated. 13 refs, 4 figs

  7. Atmospheric Stability & Turbulence from Temperature Profiles over Sicily During Summer 2002 & 2003 HASI Balloon Campaigns

    Science.gov (United States)

    Colombatti, G.; Ferri, F.; Angrilli, F.; Fulchignoni, M.

    2005-01-01

    Experimental results and interpretation of the temperature measurements data retrieved during the balloon campaigns (in 2002 and in 2003) for testing HASI (Huygens Atmospheric Structure Instrument), launched from the Italian Space Agency Base in Trapani (Sicily), are presented. Both ascending and descending phases are analysed; data reveal interesting features near the tropopause (present in the region between 11km-14km), where temperature cooling can be related to layers with strong winds (2002 flight); in the troposphere a multistratified structure of the temperature field is observed and discussed (particularly in the 2003 flight) Finally, stability and turbulence of the atmosphere are analysed; the buoyancy N2 parameters for both the flights show lowers value respect to standard tropospheric values corresponding to a lower stability of the atmosphere; still there is a higher stability above the tropopause. The energy spectrum of temperature data is consistent with the Kolmogorov theory: the characteristic k(sup -5/3) behaviour is reproduced.

  8. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  9. Equilibrium and ballooning mode stability of an axisymmetric tensor pressure tokamak

    International Nuclear Information System (INIS)

    Cooper, W.A.; Bateman, G.; Nelson, D.B.; Kammash, T.

    1980-08-01

    A force balance relation, a representation for the poloidal beta (β/sub p/), and expressions for the current densities are derived from the MHD equilibrium relations for an axisymmetric tensor pressure tokamak. Perpendicular and parallel beam pressure components are evaluated from a distribution function that models high energy neutral particle injection. A double adiabatic energy principle is derived from that of Kruskal and Oberman, with correction terms added. The energy principle is then applied to an arbitrary cross-section axisymmetric tokamak to examine ballooning instabilities of large toroidal mode number. The resulting Euler equation is remarkably similar to that of ideal MHD. Although the field-bending term is virtually unaltered, the driving term is modified because the pressures are no longer constant on a flux surface. Either a necessary or a sufficient marginal stability criterion for a guiding center plasma can be derived from this equation whenever an additional stabilizing element unique to the double adiabatic theory is either kept or neglected, respectively

  10. Nonlinear MHD simulations of the gravitational ballooning mode close to marginal stability

    International Nuclear Information System (INIS)

    Myers, S A; Dudson, B D; Wilson, H R

    2013-01-01

    The ballooning mode is thought to play a key role in the mechanism which drives the problematic edge localized modes in tokamak plasmas, and possibly in other plasma eruptions, such as in the magnetosphere. We investigate the essential nonlinear physics of this mode by simulating an instability driven by gravity in a slab of magnetized plasma; magnetic field curvature plays a similar role in toroidal confinement systems. Full ideal magnetohydrodynamics (MHD) simulations are performed, which exhibit three distinct phases of the mode's evolution: (I) a linear phase that agrees well with the predictions of linear ideal MHD; (II) a non-linear regime where the instantaneous growth rate evolves, and is somewhat lower than the linear value and (III) an explosive plasma eruption. These regimes are characterized and compared with the predictions of analytic nonlinear theory, considering cases that are close to and far from marginal stability. Evidence of a subcritical instability is demonstrated in phase II where, provided the mode's amplitude is large enough, it can develop into an eruption even for values of gravity that give linear stability. The drop in growth rate during phase II depends on the strength of the linear drive, demonstrating that the initial phases of the nonlinear evolution are also dependent on the strength of the linear drive. To extend the calculations deeper into the nonlinear regime a four-field reduced MHD model is developed, which reproduces the same features as the full ideal MHD system. (paper)

  11. Non-linear analysis and the design of Pumpkin Balloons: stress, stability and viscoelasticity

    Science.gov (United States)

    Rand, J. L.; Wakefield, D. S.

    Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures Founded upon their inTENS finite element analysis suite these activities have broadened to encompass lighter than air structures such as aerostats hybrid air-vehicles and stratospheric balloons Winzen Engineering couple many years of practical balloon design and fabrication experience with both academic and practical knowledge of the characterisation of the non-linear viscoelastic response of the polymeric films typically used for high-altitude scientific balloons Both companies have provided consulting services to the NASA Ultra Long Duration Balloon ULDB Program Early implementations of pumpkin balloons have shown problems of geometric instability characterised by improper deployment and these difficulties have been reproduced numerically using inTENS The solution lies in both the shapes of the membrane lobes and also the need to generate a biaxial stress field in order to mobilise in-plane shear stiffness Balloons undergo significant temperature and pressure variations in flight The different thermal characteristics between tendons and film can lead to significant meridional stress Fabrication tolerances can lead to significant local hoop stress concentrations particularly adjacent to the base and apex end fittings The non-linear viscoelastic response of the envelope film acts positively to help dissipate stress concentrations However creep over time may produce lobe geometry variations that may

  12. The stability of internal transport barriers to MHD ballooning modes and drift waves: A formalism for low magnetic shear and for velocity shear

    International Nuclear Information System (INIS)

    Connor, J.W.; Hastie, R.J.; Webster, A.J.; Wilson, H.R.

    2005-01-01

    Tokamak discharges with internal transport barriers (ITBs) provide improved confinement, so it is important to understand their stability properties. The stability to an important class of modes with high wave-numbers perpendicular to the magnetic field, is usually studied with the standard ballooning transformation and eikonal approach. However, ITBs are often characterised by radial q profiles that have regions of negative or low magnetic shear and by radially sheared electric fields. Both these features affect the validity of the standard method. A new approach to calculating stability in these circumstances is developed and applied to ideal MHD ballooning modes and to micro-instabilities responsible for anomalous transport. (author)

  13. Arcsecond Pointing Stability on a CubeSat Platform, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this proposal, Tyvak Nano-Satellite Systems LLC (Tyvak) will improve the state-of-the-art in low-jitter CubeSat platforms to one arc-second pointing stability....

  14. The Enhancement of Target Localization Using Ship-Borne Electro-Optical Stabilized Platform

    OpenAIRE

    Jaehoon Ha; Byungmo Kang; Kilho Hong; Jungsoo Park

    2016-01-01

    Electro-optical (EO) stabilized platforms have been widely used for surveillance and reconnaissance on various types of vehicles, from surface ships to unmanned air vehicles (UAVs). EO stabilized platforms usually consist of an assembly of structure, bearings, and motors called gimbals in which a gyroscope is installed. EO elements such as a CCD camera and IR camera, are mounted to a gimbal, which has a range of motion in elevation and azimuth and can designate and track a target. In addition...

  15. The research of a gyro-stabilized platform and POS application technology in airborne remote sensing

    Science.gov (United States)

    Xu, Jiang; Du, Qi

    2009-07-01

    The distortion of the collected images usually takes place since the attitude changes along with the flying aerocraft on airborne remote sensing. In order to get original images without distortion, it is necessary to use professional gyro-stabilized platform. In addition to this, another solution of correcting the original image distortion is to utilize later geometric rectification using position & orientation system ( POS ) data. The third way is to utilize medium-accuracy stabilized platform to control the distortion at a tolerant range, and then make use of the data obtained by high-solution posture measure system to correct the low-quality remote sensing images. The third way which takes advantage of both techniques is better than using only one of the two other ways. This paper introduces several kinds of structural forms of gyro-stabilized platforms, and POS acquiring instruments respectively. Then, the essay will make some analysis of their advantages and disadvantages, key technologies and the application experiment of the third method. After the analysis, the thesis discusses the design of the gyro-stabilized platform. The thesis provides crucial information not only for the application technology of gyro-stabilized platform and POS but also for future development.

  16. An oscillating microbalance for meteorological measurements of ice and volcanic ash accumulation from a weather balloon platform

    Science.gov (United States)

    Airey, Martin; Harrison, Giles; Nicoll, Keri; Williams, Paul; Marlton, Graeme

    2017-04-01

    A new, low cost, instrument has been developed for meteorological measurements of the accumulation of ice and volcanic ash that can be readily deployed using commercial radiosondes and weather balloons. It is based on principles used by [1], an instrument originally developed to measure supercooled liquid water profiles in clouds. This new instrument introduces numerous improvements in terms of reduced complexity and cost. It uses the oscillating microbalance principle, whereby a wire vibrating at its natural frequency is subjected to increased loading of the property to be measured. The increase in mass modifies the wire properties such that its natural frequency of oscillation changes. By measuring this frequency, the increase in mass can be inferred and transmitted to a ground base station through the radiosonde's UHF antenna via the PANDORA interface [2], which has been previously developed to provide power and connection to the radiosonde telemetry. The device consists of a simple circuit board controlled by an ATMEGA microcontroller. For calibration, the controller is capable of driving the wire at specified frequencies via excitation by a piezo sounder upon which the wire is mounted. The same piezo sounder is also used during active operation to measure the frequency of the wire in its non-driven state in order to infer the mass change on the wire. A phase-locked loop implemented on the board identifies when resonance occurs and the measured frequency is stable, prompting the microcontroller to send the measurement through the data interface. The device may be used for any application that requires the measurement of incremental mass variation e.g. ice accumulation, frosting, or particle accumulation such as dust and volcanic ash. For the solid particle accumulation, a low temperature, high-tack, adhesive may be applied to the wire prior to deployment to collect the material. In addition, the same instrument may be used for ground-based applications, such as

  17. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  18. The Effects of Matched Filter on Stable Performance of Semistrapdown Inertially Stabilized Platform

    Directory of Open Access Journals (Sweden)

    Feng Liu

    2016-01-01

    Full Text Available To enhance the optimization performance of matched filter and further improve line of sight (LOS stability of platform in inertial space, the proposed matched filter algorithm is conducted by adjusting matched filter coefficients of first-order low pass filter utilizing the regional search method based on invariance principle. The coefficients of the fraction molecule and denominator of proposed regional search algorithm are altered instead of denominator coefficients only being modified. Simulations are performed to verify the validity of inside factors performed with stabilization control model and quartz rate sensor (QRS mathematical model. The stable angular error is sharply alleviated, so the decoupling accuracy of airborne semistrapdown inertially stabilized platform is largely promoted. The optimization matched filter can effectively increase stability of LOS in inertial space.

  19. Rapid screening platform for stabilization of scFvs in Escherichia coli.

    Science.gov (United States)

    Miller, Brian R; Glaser, Scott M; Demarest, Stephen J

    2009-01-01

    The poor biophysical properties of antibody fragments such as scFvs and diabodies can preclude their use as therapeutic agents. The non-ideal biophysical properties and insufficient thermal stability of antibody fragments often leads to poor expression, poor solubility, and a predisposition of the proteins to aggregate. We have developed a general platform for engineering stability into antibody fragments. By promoting Escherichia coli cultures to secrete scFvs directly into growth media, automated screening methods can be applied to empirically evaluate multiple stability design strategies including rational, sequence-based, and structure-based designs. Once stabilized, these antibody fragments demonstrate improved expression and durability during purification, handling, and storage. Stabilized antibody fragments can also be used as building blocks for multivalent or bispecific antibody-like molecules.

  20. Micro Aerial Projector Stabilizing Projected Images Of An Airborne Robotics Projection Platform

    Science.gov (United States)

    2016-10-09

    Micro Aerial Projector - Stabilizing Projected Images Of An Airborne Robotics Projection Platform Werner Alexander Isop1, Jesus Pestana1, Gabriele...combining augmented reality and mobile robotics into a new form of human-machine interaction. Specifically, we introduce a small semi-autonomous micro aerial...it as a robotic companion, which follows the user and is able to project supportive information in the 3D environment. Fig. 1 shows an example where

  1. Report on the Second ARM Mobile Facility (AMF2) Stabilization Platform: Control Strategy and Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Coulter, Richard J. [Argonne National Lab. (ANL), Argonne, IL (United States); Martin, Timothy J. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    One of the primary objectives of the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s second Mobile Facility (AMF2) is to obtain reliable measurements from ocean-going vessels. A pillar of the AMF2 strategy in this effort is the use of a stable platform for those instruments that 1) need to look directly at, or be shaded from, direct sunlight or 2) require a truly vertical orientation. Some ARM instruments that fall into these categories include the Multi-Filter Rotating Shadow Band Radiometer (MFRSR) and the Total Sky Imager (TSI), both of which have a shadow band mechanism, upward-looking radiometry that should be exposed only to the sky, a Microwave Radiometer (MWR) that looks vertically and at specified tilt angles, and vertically pointing radars, for which the vertical component of motion is critically important. During the design and construction phase of AMF2, an inexpensive stable platform was purchased to perform the stabilization tasks for some of these instruments. Computer programs were developed to communicate with the platform controller and with an inertial measurements platform that measures true ship motion components (roll, pitch, yaw, surge, sway, and heave). The platform was then tested on a 3-day cruise aboard the RV Connecticut during June 16-18, 2010, off the east coast of the United States. This initial test period was followed by continued development of the platform control strategy and implementation as time permitted. This is a report of the results of these efforts and the critical points in moving forward.

  2. Real-time Leishmania genus master mix: a platform compatibility and stability study.

    Science.gov (United States)

    Melanson, Vanessa R; Scheirer, Jessica L; Kalina, Warren V; Wagar, Eric J

    2014-10-01

    Performing diagnostics and vector-pathogen surveillance in austere environments is challenging. On-site diagnostic/detection mitigates vector-borne disease complications during military or humanitarian deployments to disease endemic locals. The mobile molecular diagnostic platform, Joint Biological Agent Identification and Diagnostic System (JBAIDS; BioFire Diagnostics Inc., Salt Lake City, UT, USA), rapidly identifies biothreat pathogens. Although ideal for remote diagnostics, the platform was validated for specific pathogens of insignificant epidemiological consequence. Recognizing the JBAIDS's remote diagnostic/detection versatility, we tested a Leishmania genus real-time PCR master mix validated for use on the SmartCycler® (Cepheid, Sunnyvale, CA, USA) for concomitant use on the JBAIDS. We evaluated assay sensitivity, precision, and specificity of one or more Leishmania spp. on the JBAIDS and found that the JBAIDS produces superior detection sensitivity and specificity compared to the SmartCycler®. We also examined the storage stability of a bulk lot preparation of the Leishmania genus real-time PCR master mix on the SmartCycler® to ensure that long periods of frozen storage that would translate to a field environment with the JBAIDS were not detrimental to the reagent. We found that the bulk master mix maintains its stability over a 13-month time period. Overall, these studies confirm JBAIDS's versatility and demonstrate a streamlined assay development approach where reagents are compatible with both platforms. Copyright © 2014. Published by Elsevier Inc.

  3. Single-Aperture GPS-based Attitude (GPS/A) Sensor for Spin-Stabilized Platforms, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Attitude determination of spin-stabilized platforms is especially challenging. Current low-cost gyroscope technology does not lend itself to attitude determination...

  4. An implementation and test platform for wide area stability assessment methods

    DEFF Research Database (Denmark)

    Wittrock, Martin Lindholm; Jóhannsson, Hjörtur

    2013-01-01

    This paper presents a software platform developed in MatLab with the purpose of supporting research, Development and testing of wide area algorithms for stability assessment and control. The development and testing process of algorithms exploiting real time wide area data from Phasor Measurement...... Units (PMU) can be very time consuming, especially if the testing procedure is not carried out in a systematic and automatic manner. The test platform overcomes this problem by automatically importing system model parameters, topology and simulation output from a time domain simulation of an instability...... scenario and automatically generating synthetic PMU snapshots of the system conditions. To demonstrate the platform’s potential for supporting research and development of wide area algorithms, a method to detect voltage instability is implemented and tested, giving results consistent with results from...

  5. Modern methods for investigating the stability of a pitching floating platform wind turbine

    Directory of Open Access Journals (Sweden)

    M. Lennie

    2017-12-01

    Full Text Available The QBlade implementation of the lifting-line free vortex wake (LLFVW method was tested in conditions analogous to floating platform motion. Comparisons against two independent test cases using a variety of simulation methods show good agreement in thrust forces, rotor power, blade forces and rotor plane induction. Along with the many verifications already undertaken in the literature, it seems that the code performs solidly even in these challenging cases. Further to this, the key steps are presented from a new formulation of the instantaneous aerodynamic thrust damping of a wind turbine rotor. A test case with harmonic platform motion and collective blade pitch is used to demonstrate how combining such tools can lead to a better understanding of aeroelastic stability. A second case demonstrates a non-harmonic blade pitch manoeuvre showing the versatility of the instantaneous damping method.

  6. Surface enhanced Raman spectroscopy platform based on graphene with one-year stability

    Energy Technology Data Exchange (ETDEWEB)

    Tite, Teddy [Univ Lyon, UJM-Saint-Etienne, CNRS, Laboratoire Hubert Curien UMR 5516, 18 rue Professeur Benoit Lauras, F-42000 Saint-Etienne (France); Barnier, Vincent [Ecole Nationale Supérieure des Mines, CNRS, Laboratoire Georges Friedel UMR 5307, 158 cours Fauriel, F-42023 Saint-Etienne (France); Donnet, Christophe, E-mail: Christophe.Donnet@univ-st-etienne.fr [Univ Lyon, UJM-Saint-Etienne, CNRS, Laboratoire Hubert Curien UMR 5516, 18 rue Professeur Benoit Lauras, F-42000 Saint-Etienne (France); Loir, Anne–Sophie; Reynaud, Stéphanie; Michalon, Jean–Yves; Vocanson, Francis; Garrelie, Florence [Univ Lyon, UJM-Saint-Etienne, CNRS, Laboratoire Hubert Curien UMR 5516, 18 rue Professeur Benoit Lauras, F-42000 Saint-Etienne (France)

    2016-04-01

    We report the synthesis, characterization and use of a robust surface enhanced Raman spectroscopy platform with a stable detection for up to one year of Rhodamine R6G at a concentration of 10{sup −6} M. The detection of aminothiophenol and methyl parathion, as active molecules of commercial insecticides, is further demonstrated at concentrations down to 10{sup −5}–10{sup −6} M. This platform is based on large scale textured few-layer (fl) graphene obtained without any need of graphene transfer. The synthesis route is based on diamond-like carbon films grown by pulsed laser deposition, deposited onto silicon substrates covered by a Ni layer prior to diamond-like carbon deposition. The formation of fl-graphene film, confirmed by Raman spectroscopy and mapping, is obtained by thermal annealing inducing the diffusion of Ni atoms and the concomitant formation of nickel silicide compounds, as identified by Raman and Auger electron spectroscopies. The textured fl-graphene films were decorated with gold nanoparticles to optimize the efficiency of the SERS device to detect organic molecules at low concentrations. - Highlights: • Synthesis of graphene film from amorphous carbon by pulsed laser deposition with nickel catalyst • Large scale textured graphene with nanoscale roughness obtained through nickel silicide formation • Films used for surface enhanced Raman spectroscopy detection of organophosphate compounds • Stability of the SERS platforms over up to one year.

  7. Superpressure Balloon Design Using Nonlinear Viscoelasticity

    Science.gov (United States)

    Rand, James; Rand, James; Wakefield, David

    Stratospheric balloon platforms are used extensively by scientists for a variety of purposes. The typical balloon used today is the zero pressure natural shape fabricated from a thin film of linear low density polyethylene. This material has been found to possess a variety of desirable characteristics suitable to this environment. This film will remain ductile at very low temperatures which will permit it to develop large strains if necessary to satisfy equilibrium considerations. However, in order to achieve long duration flight without significant changes in altitude, the balloon should be pressurized to the extent necessary to maintain constant volume during typical variations in temperature. In the past, pressurized balloons were fabricated from other materials in order to achieve significant increases in strength. Thin films of polyester or polyimide have been used to make relatively small spheres capable of long duration flight. Unfortunately, these materials do not have the ductility of polyethylene at low temperature and are somewhat more fragile and subject to damage. In recent years various organizations have attempted to use the characteristic shape of a pumpkin to limit the stresses in a balloon envelope to that which can be accommodated by laminated fabric materials. While developing the design, analysis and construction techniques for this type of system, the use of polyethylene has been successfully demonstrated to provide a reliable envelope. This shape is achieved by using high strength members in the meridional direction to carry the very high loads generated by the pressure. These so called "tendons" have very low elongation and serve to limit the deformation of the film in that direction. However, earlier designs attempted to limit the stresses in the circumferential direction by using a lobe angle to control the stress. Unfortunately this has led to a number of stability problems with this type of balloon. In order to control the stability of

  8. A RBFNN-Based Adaptive Disturbance Compensation Approach Applied to Magnetic Suspension Inertially Stabilized Platform

    Directory of Open Access Journals (Sweden)

    Quanqi Mu

    2014-01-01

    Full Text Available Compared with traditional mechanical inertially stabilized platform (ISP, magnetic suspension ISP (MSISP can absorb high frequency vibrations via a magnetic suspension bearing system with five degrees of freedom between azimuth and pitch gimbals. However, force acting between rotor and stator will introduce coupling torque to roll and pitch gimbals. Since the disturbance of magnetic bearings has strong nonlinearity, classic state feedback control algorithm cannot bring higher precision control for MSISP. In order to enhance the control accuracy for MSISP, a disturbance compensator based on radial basis function neural network (RBFNN is developed to compensate for the disturbance. Using the Lyapunov theorem, the weighting matrix of RBFNN can be updated online. Therefore, the RBFNN can be constructed without priori training. At last, simulations and experiment results validate that the compensation method proposed in this paper can improve ISP accuracy significantly.

  9. Maturation and Hardening of the Stabilized Radiometer Platforms (STRAPS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Bucholtz, A. [U.S. Naval Research Lab. Washington, DC (United States); Bluth, R. [U.S. Naval Postgraduate School, Monterey, CA (United States); Pfaff, B. [L-3 Communications, New York, NY (United States)

    2016-04-01

    Measurements of solar and infrared irradiance by instruments rigidly mounted to an aircraft have historically been plagued by the introduction of offsets and fluctuations into the data that are solely due to the pitch and roll movements of the aircraft. Two STabilized RAdiometer Platforms (STRAPs) were developed for the U.S. Navy in the early to mid-2000s to address this problem. The development was a collaborative effort between the Naval Research Laboratory (NRL), the Naval Postgraduate School Center for Interdisciplinary Remotely Piloted Aircraft Studies (CIRPAS), and the U.S. Department of Energy (DOE) Sandia National Laboratories. The STRAPs were designed and built by L-3 Communications Sonoma EO (formerly the small business Sonoma Design Group).

  10. Crash problem definition and safety benefits methodology for stability control for single-unit medium and heavy trucks and large-platform buses

    Science.gov (United States)

    2009-10-01

    This report presents the findings of a comprehensive engineering analysis of electronic stability control (ESC) and roll stability control (RSC) systems for single-unit medium and heavy trucks and large-platform buses. This report details the applica...

  11. Comparison of ground reaction forces during the Basic Step on the Core Board platform at various levels of stability.

    Science.gov (United States)

    Karczewska, Magdalena; Madej, Anna; Sadowska, Aleksandra; Mastalerz, Andrzej; Urbanik, Czesław

    2016-01-01

    The aim of this paper was to examine and compare the changes of ground reaction forces observed during the Basic Step on the Core Board fitness device at various levels of stability. The study involved 10 female students. Participants stepped on and off the Core Board 10 times at 3 levels of stability. After completing a series of steps, the Core Board's stability was modified and the participant repeated the whole series. The measurement platform to examine three components of the reaction force (horizontal in the sagittal and frontal planes, and vertical) was used. The ground reaction force (GRF) observed on the Core Board, in the vertical and horizontal components is higher at all three levels of stability than on the platform without the device. Significant differences in GRF were observed in the horizontal component in the frontal plane (Fz) at all three levels of mobility as well as in impulse, measured on platforms with the device. The results on the Core Board training device present highest horizontal ground reaction forces in frontal plane at the highest level of Core Board mobility and this showing little medio-lateral stability and a more reactive way of movement regulation of the participants. As a consequence of the force patterns found it may be suggested that fitness training concepts should focus more possibly higher strains on the locomotor system most likely caused by changed ground reaction force patterns, an idea that has to be further analyzed with more complex measurement approaches.

  12. Vibration isolation analysis of a stabilized platform mounted on a small off-road vehicle

    CSIR Research Space (South Africa)

    Strydom, Anria

    2014-06-01

    Full Text Available Stabilised platforms are regularly integrated with vehicles in various applications such as terrain mapping and surveillance. The equipment installed on the platform is often sensitive to motion and has to be isolated from unnecessary vibrations...

  13. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  14. The MIPAS balloon borne trace constitutent experiment

    Science.gov (United States)

    Oelhaf, H.; Vonclarmann, TH.; Fischer, H.; Friedl-Vallon, F.; Fritzsche, CHR.; Piesch, CHR.; Rabus, D.; Seefeldner, M.; Voelker, W.

    1994-01-01

    A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

  15. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  16. Remote sensing and sensor testing via hot air balloons

    Energy Technology Data Exchange (ETDEWEB)

    Watson, S.M. [Univ. of Utah, Salt Lake City, UT (United States); Kroutil, R.T. [Army Edgewood Research, Development and Engineering Center, Aberdeen Proving Ground, MD (United States); Traynor, C.A. [DARPA High Performance Computing Applications, Arlington, VA (United States)] [and others

    1996-11-01

    Tethered and free-flying manned hot air balloons have been demonstrated as platforms for various remote sensing asks and sensor testing and atmospheric measurements. These platforms are inexpensive to operate, do not cause atmospheric disturbances as do higher speed platforms, and are extremely stable and free of vibrations inherent in aircraft structures. The equipment operated and tested on the balloons in connection with this project includes a prototype multispectral imaging spectrometer, high resolution CCD cameras, mid- and far-infrared cameras, a radiometer, FTIR spectrometers, video recording equipment and portable power generators carried beneath the balloon providing power to the equipment The experiments conducted on and from the balloon include chemical effluents characterization, atmospheric propagation through slant paths, obscurants imaging and scene reflectance. 7 refs.

  17. Design and analysis of power supply and information transfer to three-axis gyroscope stabilizer platform

    Directory of Open Access Journals (Sweden)

    Belyanin Lev

    2016-01-01

    Full Text Available The paper focuses on problems of the engineering implementation of 3-axis gyrostabilizer of the camera for orthophotography performed from light and ultralight aircrafts. The functional diagram of gyrostabilizer is characterized by a lighter ball-bearing having a large inner diameter used for the platform suspension on its internal (vertical axis. The problem is to transfer the supply voltage to the platform and the electric signals to and from the platform. Design solutions concerning the power supply and information transfer are supported by the experimental techniques suggested in this paper, namely: the use of the rolling contact; three-phase gyro motor power supply replaced by that from the single-phase network; signal transmission from the precession angle sensor using the air transformer; current and voltage frequency division; DC mode selection for the torquer. The results obtained prove the efficiency of the suggested design solutions.

  18. Balloon Command-Control

    Science.gov (United States)

    1977-01-07

    Continuo on reverse side Ii nocosom7’ and identify by block numnber) P cientific Balloons; Balloon flights; Telemetry; Balloon Control; plight Termination... improvements in the ground station which should result in a truly simplified operation. The final modification to the decoder board which appears... improve the sweep range nnd sweep rate, however, the wave shape is still not as good as achieved using an exter..al sine wave oscillator manually

  19. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  20. Report on the Second ARM Mobile Facility (AMF2) Roll, Pitch, and Heave (RPH) Stabilization Platform: Design and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Coulter, Richard L. [Argonne National Lab. (ANL), Argonne, IL (United States); Martin, Timothy J. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    One of the primary objectives of the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s second Mobile Facility (AMF2) is to obtain reliable measurements of solar, surface, and atmospheric radiation, as well as cloud and atmospheric properties, from ocean-going vessels. To ensure that these climatic measurements are representative and accurate, many AMF2 instrument systems are designed to collect data in a zenith orientation. A pillar of the AMF2 strategy in this effort is the use of a stable platform. The purpose of the platform is to 1) mitigate vessel motion for instruments that require a truly vertical orientation and keep them pointed in the zenith direction, and 2) allow for accurate positioning for viewing or shading of the sensors from direct sunlight. Numerous ARM instruments fall into these categories, but perhaps the most important are the vertically pointing cloud radars, for which vertical motions are a critical parameter. During the design and construction phase of AMF2, an inexpensive stable platform was purchased to perform the stabilization tasks for some of these instruments. The first table compensated for roll, pitch, and yaw (RPY) and was reported upon in a previous technical report (Kafle and Coulter, 2012). Subsequently, a second table was purchased specifically for operation with the Marine W-band cloud radar (MWACR). Computer programs originally developed for RPY were modified to communicate with the new platform controller and with an inertial measurements platform that measures true ship motion components (roll, pitch, yaw, surge, sway, and heave). This platform could not be tested dynamically for RPY because of time constraints requiring its deployment aboard the container ship Horizon Spirit in September 2013. Hence the initial motion tests were conducted on the initial cruise. Subsequent cruises provided additional test results. The platform, as tested, meets all the design and

  1. Salt marsh stability and patterns of sedimentation across a backbarrier platform

    DEFF Research Database (Denmark)

    Bartholdy, Anders; Bartholdy, Jesper; Kroon, Aart

    2010-01-01

    ) was measured at 32 locations across the studied salt marsh platform. It was found to correlate with two independent variables: (1) distance to marsh edge and (2) distance to creeks of 2nd or higher order. They explained in combination 71% of the variation. The derived algorithms for estimating the salt marsh...... deposition made it possible to tune in a model in a 4 by 4 m grid covering the studied salt marsh area of app 3 km2. This was used to describe the general pattern of deposition on the salt marsh platform. Running the model with a constant sea level revealed that balance between the inner and the outer salt...... marsh deposition cannot be achieved within a time scale of 1000s of years. Modeling salt marsh sedimentation under rising sea level scenarios revealed that only one specific sea level rise provides equilibrium for a given location. With a higher sea level rise, the marsh at the specific location...

  2. The Japanese Balloon Program

    Science.gov (United States)

    Nishimura, J.

    The Japanese scientific ballooning program has been organized by ISAS since the institute was founded in mid 1960s. Since then, the balloon group of ISAS has been engaged in the development of the balloon technologies and scientific observations in collaboration with scientists and engineers in other universities and organizations. Here, I describe several subjects of recent activities, the details of some items will also be reported in the separate papers in this meeting.Preparation of a new mobile receiving station.Balloons of made of the EVAL (Ethylene-Vinyl-Alcohol) films. EVAL film has specific Infra-red absorption bands, and is expected to be useful for saving the ballast for a long duration flight.A high altitude balloon with thin polyethylene films achieving at an altitude of above 50km. Further improvement of this type of balloons is continued by inventing how to extrude thin films less than 5 microns of thickness.Recent achievement of Antarctica Flights under the collaboration of ISAS and National Polar Institute.Other new efforts to long duration flights such as satellite link boomerang balloon systems and others.New balloon borne scientific instrumentation for observations of high energy electrons and Anti-protons in cosmic-rays.

  3. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  4. Modified Hydrogen Balloon Explosion.

    Science.gov (United States)

    Lawrence, Stephen S.

    1995-01-01

    Describes the technique of exploding an oxygen-hydrogen balloon using two balloons and having students observe the formation of water droplets. Suggests that the Socratic Method can be used to start discussions related to stochiometry, states of matter, and gas laws. (DDR)

  5. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

    Science.gov (United States)

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.

    2016-03-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.

  6. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  7. A high throughput platform for understanding the influence of excipients on physical and chemical stability

    DEFF Research Database (Denmark)

    Raijada, Dhara; Cornett, Claus; Rantanen, Jukka

    2013-01-01

    selected. Binary physical mixtures of drug and excipient were transferred to a 96-well plate followed by addition of water to simulate aqueous granulation environment. The plate was subjected for XRPD measurements followed by drying and subsequent XRPD and HPLC measurements of the dried samples. Excipients...... for chemical degradation. The proposed high-throughput platform can be used during early drug development to simulate typical processing induced stress in a small scale and to understand possible phase transformation behaviour and influence of excipients on this....

  8. System Performance of an Inertially Stabilized Gimbal Platform with Friction, Resonance, and Vibration Effects

    OpenAIRE

    Jia, Ruting; Nandikolla, Vidya K.; Haggart, Gary; Volk, Charles; Tazartes, Daniel

    2017-01-01

    The research work evaluates the quality of the sensor to perform measurements and documents its effects on the performance of the system. It also evaluates if this performance changes due to the environments and other system parameters. These environments and parameters include vibration, system friction, structural resonance, and dynamic system input. The analysis is done by modeling a gimbal camera system that requires angular measurements from inertial sensors and gyros for stabilization. ...

  9. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    (over the line of sight) than with dedicated RF system, which requires balloon visibility from the ground station. For long duration flights (3 months) of Infra Red Montgolfieres, a house keeping gondola has been developed, using the Inmarsat C standard to have communication all around the world (up to N or S 80 ° latitude) with an automatic switching between the 4 geostationnary Inmarsat satellites. After validation flights performed from Bauru / Brazil. (2000 & 2001) and Kiruna/Sweden (2002), the first operational flights took place from Bauru in February 2003 during ENVISAT validation campaign. The next flights will be realized in the framework of the Hibiscus campaign planned in February 2004 in Bauru.. The Balloon Division was involved in the Franco / Japanese HSFD II project which consists to drop a mock-up of the Japanese HOPE-X space shuttle from a stratospheric balloon to validate its flight from the altitude of 30 km. We developed a specific gondola as a service module for the HOPE-X shuttle, providing power and GPS radio-frequency signal during the balloon flight phase, telemetry end remote control radio frequency links and separation system with pyrotechnic cutters for the drop of the shuttle. A successful flight was performed at Kiruna in July 2003. Concerning gondola with pointing system, the study of a big g-ray telescope (8 m of focal length), started by the end of 2002. For this 1 ton gondola, the telescope stabilization system will be based on control moment gyro (CMG). The CMG system has been designed and will be manufactured and validated during 2004. The first flight of this g-ray gondola is planned for 2006. The progress, status and future plans concerning these gondola developments will be presented.

  10. A time domain design technique for high precision full digital pointing system in balloon-borne remote infrared sensing

    Science.gov (United States)

    Boscaleri, A.; Venturi, V.; Tronconi, A.; Colzi, R.

    1990-09-01

    The design of two motor servoloops for an azimuth stabilization of a gondola of a large telescope is described. The system uses two dc torque motors, one for any motion of the platform around the vertical axis and one placed at the interconnecting point balloon-payload for attenuating the friction bearing. Mechanical nonlinearities impose a time domain design for any settling time control whenever the gondola experiences a new step in azimuth coordinate. A simplified equations of motion in the time domain are shown which enable this settling time to be controlled. A mechanical approach using an active pivot to avoid disturbances of the balloon rotation on current tracking of the sky azimuthal target is described.

  11. A Solvent Switch for the Stabilization of Multiple Hemiacetals on an Inorganic Platform: Role of Supramolecular Interactions.

    Science.gov (United States)

    Kalita, Alok Ch; Gupta, Sandeep K; Murugavel, Ramaswamy

    2016-05-10

    Reaction of Zn(OAc)2 ⋅2 H2 O with 2,6-diisopropylphenyl phosphate (dippH2 ) in the presence of pyridine-4-carboxaldehyde (Py-4-CHO) in methanol resulted in the isolation of a tetrameric zinc phosphate cluster [Zn(dipp)(Py-4-CH(OH)(OMe))]4 ⋅4 MeOH (1) with four hemiacetal moieties stabilized on the double-4-ring inorganic cubane cluster. The change of solvent from methanol to acetonitrile leads to the formation of [Zn(dipp)(Py-4-CHO)]4 (2), in which the coordinated Py-4-CHO retains its aldehydic form. Dissolution of 1 in CD3 CN readily converts it to the aldehydic form and yields 2. Similarly 2, which exists in the aldehyde form in CD3 CN, readily converts to the hemiacetal form in CD3 OD/CH3 OH. Compound 1 is an unprecedented example in which four hemiacetals have been stabilized on a single molecule in the solid state retaining its stability in solution as revealed by its (1) H NMR spectrum in CD3 OD. The solution stability of 1 and 2 has further been confirmed by ESI-MS studies. To generalize the stabilization of multiple hemiacetals on a single double-four-ring platform, pyridine-2-carboxaldehyde (Py-2-CHO) was used as the auxiliary ligand in the reaction between zinc acetate and dippH2 , leading to isolation of [Zn(dipp)(Py-2-CH(OH)(OMe))]4 (3). Understandably, recrystallization of 3 from acetonitrile yields the parent aldehydic form, [Zn(dipp)(Py-2-CHO)]4 (4). Single-crystal X-ray diffraction studies reveal that supramolecular bonding, aided by hydrogen-bonding interactions involving the hemiacetal functionalities (C-OH, C-OMe, and C-H), are responsible for the observed stabilization. The hemiacetal/aldehyde groups in 1 and 2 readily react with p-toluidine, 2,6-dimethylaniline, and 4-bromoaniline to yield the corresponding tetra-Schiff base ligands, [Zn(dipp)(L)]4 (L=4-methyl-N-(pyridin-4-ylmethylidene)aniline (5), 2,6-dimethyl-N-(pyridin-4-ylmethylene)-aniline (6), and 4-bromo-N-(pyridin-4-ylmethylene)aniline (7)). Isolation of 5-7 opens up further

  12. A Model Reference Adaptive Control/PID Compound Scheme on Disturbance Rejection for an Aerial Inertially Stabilized Platform

    Directory of Open Access Journals (Sweden)

    Xiangyang Zhou

    2016-01-01

    Full Text Available This paper describes a method to suppress the effect of nonlinear and time-varying mass unbalance torque disturbance on the dynamic performances of an aerial inertially stabilized platform (ISP. To improve the tracking accuracy and robustness of the ISP, a compound control scheme based on both of model reference adaptive control (MRAC and PID control methods is proposed. The dynamic model is first developed which reveals the unbalance torque disturbance with the characteristic of being nonlinear and time-varying. Then, the MRAC/PID compound controller is designed, in which the PID parameters are adaptively adjusted based on the output errors between the reference model and the actual system. In this way, the position errors derived from the prominent unbalance torque disturbance are corrected in real time so that the tracking accuracy is improved. To verify the method, the simulations and experiments are, respectively, carried out. The results show that the compound scheme has good ability in mass unbalance disturbance rejection, by which the system obtains higher stability accuracy compared with the PID method.

  13. The University of Alberta High Altitude Balloon Program

    Science.gov (United States)

    Johnson, W.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Mann, I. R.; Mazzino, L.; Rae, J.; University of Alberta High Altitude Balloon Team

    2011-12-01

    The University of Alberta High Altitude Balloon (UA-HAB) program is a one and half year program sponsored by the Canadian Space Agency (CSA) that offers hands on experience for undergraduate and graduate students in the design, build, test and flight of an experimental payload on a high altitude balloon platform. Utilising low cost weather balloon platforms, and through utilisation of the CSA David Florida Laboratory for thermal-vacuum tests , in advance of the final flight of the payload on a NASA high altitude balloon platform. Collectively the program provided unique opportunities for students to experience mission phases which parallel those of a space satellite mission. The program has facilitated several weather balloon missions, which additionally provide educational opportunities for university students and staff, as well as outreach opportunities among junior and senior high school students. Weather balloon missions provide a cheap and quick alternative to suborbital missions; they can be used to test components for more expensive missions, as well as to host student based projects from different disciplines such as Earth and Atmospheric Sciences (EAS), Physics, and Engineering. In addition to extensive skills development, the program aims to promote recruitment of graduate and undergraduate students into careers in space science and engineering. Results from the UA-HAB program and the flight of the UA-HAB shielded Gieger counter payload for cosmic ray and space radiation studies will be presented. Lessons learned from developing and maintaining a weather balloon program will also be discussed. This project is undertaken in partnership with the High Altitude Student Platform, organized by Louisiana State University and the Louisiana Space Consortium (LaSpace), and sponsored by NASA, with the financial support of the Canadian Space Agency.

  14. High n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An, C.H.; Bateman, G.

    1980-02-01

    An analytic study of stability against high n ballooning modes in highly elongated axisymmetric plasmas is presented and compared with computational results. From the equation for the marginal pressure gradient, it is found that the local shear plays an important role on the stability of elongated and shifted plasma, and that high elongation deteriorates the stability by decreasing the stabilizing effects of field line bending and local shear. The net contribution of the local shear to stability decreases with elongation and shift for strongly ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). The computational study of high n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for β/sub p/ less than unity but severely reduce the marginal beta for β/sub p/ larger than unity

  15. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  16. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  17. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  18. Effects of different foot progression angles and platform settings on postural stability and fall risk in healthy and medial knee osteoarthritic adults.

    Science.gov (United States)

    Khan, Saad Jawaid; Khan, Soobia Saad; Usman, Juliana; Mokhtar, Abdul Halim; Abu Osman, Noor Azuan

    2018-02-01

    This study aims to investigate the effects of varying toe angles at different platform settings on Overall Stability Index of postural stability and fall risk using Biodex Balance System in healthy participants and medial knee osteoarthritis patients. Biodex Balance System was employed to measure postural stability and fall risk at different foot progression angles (ranging from -20° to 40°, with 10° increments) on 20 healthy (control group) and 20 knee osteoarthritis patients (osteoarthritis group) randomly (age: 59.50 ± 7.33 years and 61.50 ± 8.63 years; body mass: 69.95 ± 9.86 kg and 70.45 ± 8.80 kg). Platform settings used were (1) static, (2) postural stability dynamic level 8 (PS8), (3) fall risk levels 12 to 8 (FR12) and (4) fall risk levels 8 to 2 (FR8). Data from the tests were analysed using three-way mixed repeated measures analysis of variance. The participant group, platform settings and toe angles all had a significant main effect on balance ( p ≤ 0.02). Platform settings had a significant interaction effect with participant group F(3, 144) = 6.97, p fall risk as compared to the healthy group. Changing platform settings has a more pronounced effect on balance in knee osteoarthritis group than in healthy participants. Changing toe angles produced similar effects in both the participant groups, with decreased stability and increased fall risk at extreme toe-in and toe-out angles.

  19. Therapeutic balloon-assisted enteroscopy

    NARCIS (Netherlands)

    H. Aktas (Huseyin); P.B.F. Mensink (Peter)

    2009-01-01

    textabstractSince the introduction of the first balloon-based enteroscopic technique in 2001, therapeutic balloon-assisted enteroscopy (BAE) using either the single or double balloon enteroscopy technique (respectively SBE and DBE) has evolved rapidly. Argon plasma coagulation (APC), polypectomy,

  20. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    . Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  1. Balloon Borne Arc-Second Pointer Feasibility Study

    Science.gov (United States)

    Ward, Philip R.; DeWeese, Keith D.

    2003-01-01

    For many years scientists have been utilizing stratospheric balloons as low-cost platforms on which to conduct space science experiments. A major hurdle in extending the range of experiments for which these vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target. A significant number of scientists have sought the ability to point their instruments with jitter in the arc-second range. This paper presents the design and analysis of a stratospheric balloon borne pointing system that is able to meet this requirement. The foundation for a high fidelity controller simulation is presented. The flexibility of the flight train is represented through generalized modal analysis. A multiple controller scheme is introduced for coarse and fine pointing. Coarse azimuth pointing is accomplished by an established pointing system, with extensive flight history, residing above the gondola structure. A pitch-yaw gimbal mount is used for fine pointing, providing orthogonal axes when nominally on target. Fine pointing actuation is from direct drive dc motors, eliminating backlash problems. An analysis of friction nonlinearities and a demonstration of the necessity in eliminating static fiction are provided. A unique bearing hub design is introduced that eliminates static fiction from the system dynamics. A control scheme involving linear accelerometers for enhanced disturbance rejection is also presented. Results from a linear analysis of the total system and the high fidelity simulation are given. This paper establishes that the proposed control strategy can be made robustly stable with significant design margins. Also demonstrated is the efficacy of the proposed system in rejecting disturbances larger than those considered realistic. Finally, we see that sub arc-second pointing stability can be achieved for a large instrument pointing at an inertial target.

  2. Planetary Science with Balloon-Borne Telescopes

    Science.gov (United States)

    Kremic, Tibor; Cheng, Andy; Hibbitts, Karl; Young, Eliot

    2015-01-01

    The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some

  3. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  4. Experimental characterization and numerical modelling of polymeric film damage, constituting the stratospheric super pressurized balloons

    Science.gov (United States)

    Chaabane, Makram; Chaabane, Makram; Dalverny, Olivier; Deramecourt, Arnaud; Mistou, Sébastien

    The super-pressure balloons developed by CNES are a great challenge in scientific ballooning. Whatever the balloon type considered (spherical, pumpkin...), it is necessary to have good knowledge of the mechanical behavior of the envelope regarding to the flight level and the lifespan of the balloon. It appears during the working stages of the super pressure balloons that these last can exploded prematurely in the course of the first hours of flight. For this reason CNES and LGP are carrying out research programs about experimentations and modelling in order to predict a good stability of the balloons flight and guarantee a life time in adequacy with the technical requirement. This study deals with multilayered polymeric film damage which induce balloons failure. These experimental and numerical study aims, are a better understanding and predicting of the damage mechanisms bringing the premature explosion of balloons. The following damages phenomena have different origins. The firsts are simple and triple wrinkles owed during the process and the stocking stages of the balloons. The second damage phenomenon is associated to the creep of the polymeric film during the flight of the balloon. The first experimental results we present in this paper, concern the mechanical characterization of three different damage phenomena. The severe damage induced by the wrinkles of the film involves a significant loss of mechanical properties. In a second part the theoretical study, concerns the choice and the development of a non linear viscoelastic coupled damage behavior model in a finite element code.

  5. Balloon-borne Infrared Telescope (BIRT) for far-infrared spectroscopy

    Science.gov (United States)

    Shibai, Hiroshi; Okuda, Haruyuki; Nakagawa, Takao; Yajima, Nobuyuki; Maihara, Toshinori; Mizutani, Kohei; Matsuhara, Hideo; Kobayashi, Yukiyasu; Hiromoto, Norihisa; Takami, Hideki

    1990-07-01

    The Japanese-made Balloon-borne Infrared Telescope (BIRT) designed for FIR astronomy is described. The BIRT system includes a 50-cm-diam telescope; an attitude-control system consisting of an attitude stabilization and a pointing and tracking subsystems; the ground support system consisting of four personal-computer systems; and electronics consisting of three small computer systems, servo circuits, power amplifiers, and other small circuits. Between 1985 and 1988, the BIRT has flown eight times, demonstrating that it is able to provide a suitable telescope observations on a stable platform with a long integration time. Structural diagrams of the BIRT overall system, the optical system, and the wobbling mechanism are presented along with a block diagram of the on-board electronics.

  6. VVER ballooning experiments

    International Nuclear Information System (INIS)

    Gyoeri, Cs.; Hozer, Z.; Maroti, L.; Matus, L.

    1998-01-01

    A series of ballooning experiments was performed at the KFKI-AEKI in order to compare the mechanical behaviour and strength of Zircaloy-4 and Zr1%Nb claddings. The effects of temperature, oxidation and iodine absorption on deformation and burst pressure was investigated in almost 100 biaxial tests. Numerical post-test analyses have also been performed with the stand-alone fuel module of the French CATHARE code and the US fuel behaviour code FRAP-T6. Comparing the experimental and the analytical results, relevant differences of high temperature strength due to different α-β phase transition temperature were revealed between the investigated cladding materials. (author)

  7. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  8. Aerodynamics of a Party Balloon

    Science.gov (United States)

    Cross, Rod

    2007-01-01

    It is well-known that a party balloon can be made to fly erratically across a room, but it can also be used for quantitative measurements of other aspects of aerodynamics. Since a balloon is light and has a large surface area, even relatively weak aerodynamic forces can be readily demonstrated or measured in the classroom. Accurate measurements…

  9. Resistive G-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Mondt, J.P.; Paris, R.B.

    1980-01-01

    A unified theory of the linear stability of the Roberts and Taylor type of resistive interchange and ballooning is presented. The effects of both parallel and perpendicular viscosity as well as of finite shear and finite β are included in a MHD treatment of the problem. Kinetic effects are also studied. The hybrid kinetic model with Vlasov ions and guiding center electrons has been appropriately generalized to allow for electron-ion collisions. The geometry is that of a plane slab with magnetic shear

  10. Air Force Cambridge Research Laboratories balloon operations

    Science.gov (United States)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  11. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  12. A composite control method based on the adaptive RBFNN feedback control and the ESO for two-axis inertially stabilized platforms.

    Science.gov (United States)

    Lei, Xusheng; Zou, Ying; Dong, Fei

    2015-11-01

    Due to the nonlinearity and time variation of a two-axis inertially stabilized platform (ISP) system, the conventional feedback control cannot be utilized directly. To realize the control performance with fast dynamic response and high stabilization precision, the dynamic model of the ISP system is expected to match the ideal model which satisfies the desired control performance. Therefore, a composite control method based on the adaptive radial basis function neural network (RBFNN) feedback control and the extended state observer (ESO), is proposed for ISP. The adaptive RBFNN is proposed to generate the feedback control parameters online. Based on the state error information in the working process, the adaptive RBFNN can be constructed and optimized directly. Therefore, no priori training data is needed for the construction of the RBFNN. Furthermore, a linear second-order ESO is constructed to compensate for the composite disturbance. The asymptotic stability of the proposed control method has been proven by the Lyapunov stability theory. The applicability of the proposed method is validated by a series of simulations and flight tests. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  13. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  14. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  15. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  16. US Monthly Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Monthly winds aloft summary forms summarizing Pilot Balloon observational data for the United States. Generally labeled as Form 1114, and then transitioning to Form...

  17. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  18. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  19. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  20. Ballooning instabilities in tokamaks with sheared toroidal flows

    International Nuclear Information System (INIS)

    Waelbroeck, F.L.; Chen, L.

    1990-11-01

    The stability of ballooning modes in the presence of sheared toroidal flows is investigated. The eigenmodes are shown to be related by a Fourier transformation to the non-exponentially growing Floquet solutions found by Cooper. It is further shown that the problem cannot be reduced further than to a two dimensional partial differential equation. Next, the generalized ballooning equation is solved analytically for a circular tokamak equilibrium with sonic flows, but with a small rotation shear compared to the sound speed. With this ordering, the centrifugal forces are comparable to the pressure gradient forces driving the instability, but coupling of the mode with the sound wave is avoided. A new stability criterion is derived which explicitly demonstrates that flow shear is stabilizing at constant centrifugal force gradient. 34 refs

  1. Stability optimisation of molecular electronic devices based on  nanoelectrode–nanoparticle bridge platform in air and different storage liquids

    International Nuclear Information System (INIS)

    Jafri, S. H. M.; Blom, T.; Wallner, A.; Ottosson, H.; Leifer, K.

    2014-01-01

    The long-term stability of metal nanoparticle–molecule junctions in molecular electronic devices based on nanoelectrodes (NEL) is a major challenge in the effort to bring related molecular electronic devices to application. To optimize the reproducibility of molecular electronic nanodevices, the time-dependent modification of such junctions as exposed to different media needs to be known. Here, we have studied (1) the stability of Au-NEL and (2) the electrical stability of molecule–Au nanoparticle (AuNP) junctions themselves with the molecule being  1,8-octanedithiol (ODT). Both the NELs only and the junctions were exposed to air and liquids such as deionized water, tetrahydrofuran, toluene and tetramethylethylenediamine (TMEDA) over a period of 1 month. The nanogaps remained stable in width when stored in either deionized water or toluene, whereas the current through 1,8-octanedithiol–NP junctions remained most stable when stored in TMEDA as compared to other solvents. Although it is difficult to follow the chemical processes in such devices in the 10-nm range with analytical methods, the behavior can be interpreted from known interactions of solvent molecules with electrodes and ODT

  2. Cu Microbelt Network Embedded in Colorless Polyimide Substrate: Flexible Heater Platform with High Optical Transparency and Superior Mechanical Stability.

    Science.gov (United States)

    Lee, Ji-Hyun; Youn, Doo-Young; Luo, Zhenhao; Moon, Ji Young; Choi, Seon-Jin; Kim, Chanhoon; Kim, Il-Doo

    2017-11-15

    Metal nanowires have been considered as essential components for flexible transparent conducting electrodes (TCEs) with high transparency and low sheet resistance. However, large surface roughness and high interwire junction resistance limit the practical use of metal wires as TCEs. Here, we report Cu microbelt network (Cu MBN) with coalescence junction and low surface roughness for next-generation flexible TCEs. In particular, the unique embedded structure of Cu MBN in colorless polyimide (cPI) film was achieved to reduce the surface roughness as well as enhance mechanical stability. The TCEs using junction-free Cu MBN embedded in cPI exhibited excellent mechanical stability up to 100 000 bending cycles, high transparency of 95.18%, and a low sheet resistance of 6.25 Ω sq -1 . Highly robust Cu MBN-embedded cPI-based TCE showed outstanding flexible heater performance, i.e., high saturation temperature (120 °C) at very low voltage (2.3 V), owing to the high thermal stability of cPI and excellent thermal conductivity of the Cu MBN.

  3. Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Frederico Santos Lages

    Full Text Available Resonance frequency analysis (RFA has become the main tool used to assess the osseointegration of dental implants. The objective of this study was to verify the relationship between the ISQ values with different prosthetic abutments and with the implant platform. The hypothesis was that ISQ values changes according to the abutment height. Twelve patients were included, whose contribution to the study was 31 dental implants (external hexagon connection implants, 4.1x10 mm. The temporary implant-supported crown and prosthetic components were removed and the following smartpegs were inserted, one at a time: type 1, in the implant platform (G1; type A3, in the microunit component with 1mm transmucosal height (G2 and type A3, in the microunit component with 5mm transmucosal height (G3. In all the smartpegs, RFA measurements were taken on mesial, distal, buccal and lingual surfaces. All evaluations were performed by a single calibrated examiner (ICC = 0.989. Data were analyzed by Friedman and Spearman correlation tests and log-linear marginal regression (p<0.05. The mean age of participants was 52.83 (± 3.77 years. There was statistically significant difference (p<0.001 among the mean ISQ of G1 (88.27 ±5.70; G2 (72.75 ±4.73 and G3 (66.33 ±3.67. There was statistically significant negative correlation between the ISQ and the measurement distance (rs:-0.852; p<0.001; R2:0.553. Measurement distance was significantly associated (p<0.001 with ISQ value in the log-linear regression. The abutment height has a significant impact on resonance frequency analysis measurements. The higher the transmucosal abutment height, the lower the implant stability quotient value. Clinically, the ISQ measured on the abutment cannot be compared with values measured on the implant platform.

  4. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  5. Hardware, integration & support for the ASI BIRBA balloon campaigns since year 2000

    Science.gov (United States)

    Donati, A.; Petracchi, L.; Neri, G.; Zolesi, V.

    In the history of the space exploration, the stratospheric balloons have been among the first platforms used to carry out scientific experiments. The Italian Space Agency (ASI) has a long experience of missions with sounding balloons, managing the launch base of Trapani-Milo and executing launches over the Mediterranean sea with flight duration of about 24 hours. From year 2000 Kayser Italia (KI) have been commissioned by ASI to develop incubators for biology and physical science to be used for balloon missions, and to provide mission support during the balloon campaigns. On this basis KI developed the BIRBA incubator, that was used in four mission campaigns from 2000 to 2002. A large set of BIRBA incubators are currently available at ASI for carrying out new mission campaigns.

  6. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  7. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  8. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  9. Integrated hot-melt extrusion - injection molding continuous tablet manufacturing platform: Effects of critical process parameters and formulation attributes on product robustness and dimensional stability.

    Science.gov (United States)

    Desai, Parind M; Hogan, Rachael C; Brancazio, David; Puri, Vibha; Jensen, Keith D; Chun, Jung-Hoon; Myerson, Allan S; Trout, Bernhardt L

    2017-10-05

    This study provides a framework for robust tablet development using an integrated hot-melt extrusion-injection molding (IM) continuous manufacturing platform. Griseofulvin, maltodextrin, xylitol and lactose were employed as drug, carrier, plasticizer and reinforcing agent respectively. A pre-blended drug-excipient mixture was fed from a loss-in-weight feeder to a twin-screw extruder. The extrudate was subsequently injected directly into the integrated IM unit and molded into tablets. Tablets were stored in different storage conditions up to 20 weeks to monitor physical stability and were evaluated by polarized light microscopy, DSC, SEM, XRD and dissolution analysis. Optimized injection pressure provided robust tablet formulations. Tablets manufactured at low and high injection pressures exhibited the flaws of sink marks and flashing respectively. Higher solidification temperature during IM process reduced the thermal induced residual stress and prevented chipping and cracking issues. Polarized light microscopy revealed a homogeneous dispersion of crystalline griseofulvin in an amorphous matrix. DSC underpinned the effect of high tablet residual moisture on maltodextrin-xylitol phase separation that resulted in dimensional instability. Tablets with low residual moisture demonstrated long term dimensional stability. This study serves as a model for IM tablet formulations for mechanistic understanding of critical process parameters and formulation attributes required for optimal product performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  11. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  12. Balloon-borne disposable radiometer for cloud detection.

    Science.gov (United States)

    Nicoll, K A; Harrison, R G

    2012-02-01

    A low cost, disposable instrument for measuring solar radiation during meteorological balloon flights through cloud layers is described. Using a photodiode detector and low thermal drift signal conditioning circuitry, the device showed less than 1% drift for temperatures varied from +20 °C to -35 °C. The angular response to radiation, which declined less rapidly than the cosine of the angle between the incident radiation and normal incidence, is used for cloud detection exploiting the motion of the platform. Oriented upwards, the natural motion imposed by the balloon allows cloud and clear air to be distinguished by the absence of radiation variability within cloud, where the diffuse radiation present is isotropic. The optical method employed by the solar radiation instrument has also been demonstrated to provide higher resolution measurements of cloud boundaries than relative humidity measurements alone.

  13. N-dependence of ballooning instabilities

    International Nuclear Information System (INIS)

    Dewar, R.L.; Manickam, J.; Grimm, R.C.; Chance, M.S.

    1980-05-01

    The critical β for stability against ideal hydromagnetic internal ballooning modes as a function of toroidal mode number, n, is calculated for two different equilibrium sequences by use of a finite element technique (n less than or equal to 20), and a WKB formalism (n greater than or equal to 5). The agreement between the two methods is good in the overlap region 5 approx.less than or equal to n approx. less than or equal to 20. The WKB formula reduces to the 1/n correction at very high n, but is much more accurate at moderate n. The critical β vs n curves exhibit oscillatory structure at low n, but in both sequences the lower bound on β/sub c/ approx. 5%. For reactor parameters, finite Larmor radius effects are not expected to have a large effect on this β-limitation

  14. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  15. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  16. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  17. Assessing the Potential of Stratospheric Balloons for Planetary Science

    Science.gov (United States)

    Kremic, Tibor; Hibbitts, Karl; Young, Eliot; Landis, Robert; Noll, Keith; Baines, Kevin

    2013-01-01

    Recent developments in high altitude balloon platform capabilities, specifically long duration flights in excess of 50 days at over 100,000 ft and precision pointing with performance at the arc sec level or better have raised the question whether this platform can be utilized for high-value planetary science observations. In January of 2012 a workshop was held at NASA Glenn Research Center in Cleveland, Ohio to explore what planetary science can be achieved utilizing such a platform. Over 40 science concepts were identified by the scientists and engineers attending the workshop. Those ideas were captured and then posted to a public website for all interested planetary scientists to review and give their comments. The results of the workshop, and subsequent community review, have demonstrated that this platform appears to have potential for high-value science at very competitive costs. Given these positive results, the assessment process was extended to include 1) examining, in more detail, the requirements for the gondola platform and the mission scenarios 2) identifying technical challenges and 3) developing one or more platform concepts in enough fidelity to enable accurate estimating of development and mission costs. This paper provides a review of the assessment, a summary of the achievable science and the challenges to make that science a reality with this platform.

  18. Scientific ballooning: Past, present and future

    Science.gov (United States)

    Jones, W. Vernon

    2013-02-01

    Balloons have been used for scientific research since they were invented in France more than 200 years ago. Cosmic rays were discovered 100 years ago with an experiment flown on a manned balloon. A major change in balloon design occurred in 1950 with the introduction of the socalled natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for the past half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing a super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. Ultra-long-duration balloon (ULDB) flights enabled by constant-volume balloons should result in an even greater sea change in scientific ballooning than the inauguration of long-duration balloon (LDB) flights in Antarctica during the 1990-91 austral summer.

  19. Balloon Platform for Ultra-Low-Background Spectroscopy

    Data.gov (United States)

    National Aeronautics and Space Administration — Far-infrared astronomical observations are limited by foreground emission originating within the atmosphere or instrument optics. A new observing technique combining...

  20. Developing Instrumentation for Ground and Balloon-Borne Observing Platforms

    Data.gov (United States)

    National Aeronautics and Space Administration — In my research I will focus on developing hardware and software technology for two instruments searching for polarization in the Cosmic Microwave Background (CMB)....

  1. Development of scientific ballooning in Japan

    Science.gov (United States)

    Nishimura, Jun

    On the occasion of the 50th Anniversary Celebration of COSPAR of this year of 2008, it is worthwhile to summarize the results of the Scientific ballooning in early days in connection with the recent developments in various countries. Nishina Laboratories, Riken, had started the observations of cosmic rays with rubber balloons as early as 1942. However it was interrupted soon by the war II. After the war, new research group started in collaboration with several universities with nuclear emulsions put on the rubber balloons in 1950, and then soon after the group manufactured by themselves and launched the first plastic balloon in 1953. Based on additional technologies during a few years developed by these group, the Institute of Nuclear Study, INS, the University of Tokyo, organized the large campaign of 14 emulsion chambers and a pellicle stack with 8 plastic balloons in 1956. It is to be noted that the project was one of the largest in the world standard in those days. By the experience of this campaign, the importance of the balloon technologies was more recognized, and INS organized the group to study the balloon technologies, and had established some developments. The systematic study of scientific ballooning has started, when the scientific ballooning laboratory was founded in 1965, in the new Institute of ISAS, the University of Tokyo. The permanent balloon base of "Sanriku Balloon Center" was founded in 1971. This group has expended all efforts for the scientific ballooning, launching 10-20 balloons in each year with new inventions such as the studies of; Technologies to manufacture the reliable plastic balloons, New Balloon materials, New instrumentations for scientific ballooning, Systems of long duration flights including Antarctica flights, International collaboratiom, etc. Up to now almost 600 plastic balloons were launched during past 50 years. Then the scientific balloonings have played important and indispensable roles for the development of space

  2. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    von Doetinchem, P.; Kirn, T.; Yearwood, G.Roper; Schael, S.

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  3. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  4. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  5. Merenje parametara kretanja vozila bez žiroskopski stabilisanih platformi / Measurement of vehicle parameters of motion without gyro-stabilized platforms

    Directory of Open Access Journals (Sweden)

    Miroslav Demić

    2007-01-01

    Full Text Available Prostorni položaj težišta vozila i rotacije karoserije značajni su za analizu dinamike, ponašanje na putu, oscilatornu udobnost vozila, bezbedno odvijanje saobraćaja i sl. Pomenuti parametri se u fazi projektovanja vozila određuju metodama dinamičke simulacije, a kod izvedenih vozila merenjima u stvarnim eksploatacionim uslovima. Problem koji je u ovom radu razmotren odnosi se na praktična merenja parametara kretanja vozila. Naime, translatorne koordinate težišta vozila se, uobičajeno, utvrđuju na osnovu registrovanih linearnih ubrzanja težišta vozila (koja se kasnije, jednom ili dva puta, integrale radi izračunavanja brzine ili pomeranja, a uglovi rotacije karoserije se najčešće, mere žiroskopski stabilisanim platformama. Problem koji se pri tome javlja je cena pomenutih platformi (do sto hiljada evra, pa je retko koja institucija njima opremljena. U ovom radu nastojano je da se utvrde parametri kretanja vozila na osnovu šest registrovanih linearnih ubrzanja karakterističnih tačaka vozila. / Spatial position of vehicle C.G. as well as angular parameters of body rotation are of major importance for analysis of vehicle dynamics, handling vibrational comfort, safe service in traffic etc. The mentioned parameters are determined by use of methods of dynamic simulation in phase of development, and by means of test measurement for vehicles in real service conditions. The problem that is to be taken into consideration here is related to practical measurement of vehicle motion parameters. Translational coordinates of vehicle C.G. are usually measured on the basis of registered linear accelerations of vehicle C.G. (once or twice integrated later, for calculation of displacement or velocity and body angles are usually measured on gyroscope-stabilized platforms. The problem which occurs in these cases is the platform price (up to 100.000 EUR, not easily affordable for researchers. This paper attempts to determine vehicle motion

  6. Platform Constellations

    DEFF Research Database (Denmark)

    Staykova, Kalina Stefanova; Damsgaard, Jan

    2016-01-01

    This research paper presents an initial attempt to introduce and explain the emergence of new phenomenon, which we refer to as platform constellations. Functioning as highly modular systems, the platform constellations are collections of highly connected platforms which co-exist in parallel...... and as such allow us to study platforms not only as separate entities, but also to investigate the relationship between several platforms offered and governed by one and the same platform provider. By investigating two case studies of indigenous platform constellations formed around the hugely popular instant...

  7. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  8. Current trends of balloon laryngoplasty in Thailand.

    Science.gov (United States)

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  9. L-tyrosine immobilized on multiwalled carbon nanotubes: a new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Pacheco, Pablo H; Gil, Raúl A; Smichowski, Patricia; Polla, Griselda; Martinez, Luis D

    2009-12-10

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 micromol of Tl(III) g(-1) of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3sigma) by STPF-ETAAS was 150 ng L(-1). The detection limit (3sigma) for Tl(III) employing the separation system was 3 ng L(-1), with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 microg L(-1) of Tl(III), and 3.69-3.91 microg L(-1) of total thallium.

  10. L-Tyrosine immobilized on multiwalled carbon nanotubes: A new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Pablo H.; Gil, Raul A. [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina); Smichowski, Patricia, E-mail: smichows@cnea.gov.ar [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, CP C1033 AAJ, Ciudad de Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral. Paz 1499, B1650KNA San Martin (Argentina); Polla, Griselda [Comision Nacional de Energia Atomica, Gerencia de Investigacion y Aplicaciones, Av.Gral. Paz 1499, B1650KNA San Martin (Argentina); Martinez, Luis D., E-mail: ldm@unsl.edu.ar [Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, CP 5700, San Luis (Argentina)

    2009-12-10

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 {mu}mol of Tl(III) g{sup -1} of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3{sigma}) by STPF-ETAAS was 150 ng L{sup -1}. The detection limit (3{sigma}) for Tl(III) employing the separation system was 3 ng L{sup -1}, with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 {mu}g L{sup -1} of Tl(III), and 3.69-3.91 {mu}g L{sup -1} of total thallium.

  11. L-Tyrosine immobilized on multiwalled carbon nanotubes: A new substrate for thallium separation and speciation using stabilized temperature platform furnace-electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pacheco, Pablo H.; Gil, Raul A.; Smichowski, Patricia; Polla, Griselda; Martinez, Luis D.

    2009-01-01

    An approach for the separation and determination of inorganic thallium species is described. A new sorbent, L-tyrosine-carbon nanotubes (L-tyr-CNTs), was used and applied to the analysis of tap water samples. At pH 5.0, L-tyr was selective only towards Tl(III), while total thallium was determined directly by stabilized temperature platform furnace-electrothermal atomic absorption spectrometry (STPF-ETAAS). The Tl(III) specie, which was retained by L-tyrosine, was quantitatively eluted from the column with 10% of nitric acid. An on-line breakthrough curve was used to determine the column capacity, which resulted to be 9.00 μmol of Tl(III) g -1 of L-tyr-CNTs with a molar ratio of 0.14 (moles of Tl bound to moles of L-tyr at pH 5). Transient peak areas revealed that Tl stripping from the column occurred instantaneously. Effects of sample flow rate, concentration and flow rate of the eluent, and interfering ions on the recovery of the analyte were systematically investigated. The detection limit for the determination of total thallium (3σ) by STPF-ETAAS was 150 ng L -1 . The detection limit (3σ) for Tl(III) employing the separation system was 3 ng L -1 , with an enrichment factor of 40. The precision of the method expressed as the relative standard deviation (RSD) resulted to be 3.4%. The proposed method was applied to the speciation and determination of inorganic thallium in tap water samples. The found concentrations were in the range of 0.88-0.91 μg L -1 of Tl(III), and 3.69-3.91 μg L -1 of total thallium.

  12. Methodology for evaluation of the stability of electric systems of offshore oil platforms in interconnected operations; Metodologia para a avaliacao dos sistemas eletricos das plataformas de petroleo offshore em operacao interligada

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Dalmo Junior; Mendes, Pedro Paulo de Carvalho [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)

    2004-07-01

    The electric system of the platforms usually operates in an isolated way, requesting therefore a redundancy in the generating units so that a can have a reliable and uninterrupted system of their loads. A way to improve the quality in operation in terms of safety, reliability and economy can be the connection of the platforms of petroleum that are close, since it is viable. The objective of this work is to show the methodology for the stability study of the electric system in interlinked operation in way to detail the data of the equipment that are necessary, as: One line Diagram; Transmission lines; Transformers; Power system compensator; Generating; Speed regulators; Voltage regulators; Turbines and other. Another focus of the work is to show some control models and regulation of the electric system to maintain it stable and to show models for the interconnection of two or more platforms. (author)

  13. Anisotropic Alfven-ballooning modes in the Earth's magnetosphere

    International Nuclear Information System (INIS)

    Chan, A.A.; Xia, Mengfen; Chen, Liu

    1993-05-01

    We have carried out a theoretical analysis of the stability and parallel structure of coupled shear-Alfven and slow-magnetosonic waves in the Earth's inner magnetosphere including effects of finite anisotropic plasma pressure. Multiscale perturbation analysis of the anisotropic Grad-Shafranov equation yields an approximate self-consistent magnetohydrodynamic (MHD) equilibrium. This MHD equilibrium is used in the numerical solution of a set of eigenmode equations which describe the field line eigenfrequency, linear stability, and parallel eigenmode structure. We call these modes anisotropic Alfven-ballooning modes. The main results are: The field line eigenfrequency can be significantly lowered by finite pressure effects. The parallel mode structure of the transverse wave components is fairly insensitive to changes in the plasma pressure but the compressional magnetic component can become highly peaked near the magnetic equator due to increased pressure, especially when P perpendicular > P parallel. For the isotropic case ballooning instability can occur when the ratio of the plasma pressure to the magnetic pressure, exceeds a critical value β o B ∼ 3.5 at the equator. Compared to the isotropic case the critical beta value is lowered by anisotropy, either due to decreased field-line-bending stabilization when P parallel > P perpendicular, or due to increased ballooning-mirror destabilization when P perpendicular > P parallel. We use a ''β-6 stability diagram'' to display the regions of instability with respect to the equatorial values of the parameters bar β and δ, where bar β = (1/3)(β parallel + 2 β perpendicular) is an average beta value and δ = 1 - P parallel/P perpendicular is a measure of the plasma anisotropy

  14. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  15. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  16. Simulation of stratospheric balloon environment

    International Nuclear Information System (INIS)

    Sable, C.

    1974-01-01

    The behavior of materials used for the construction of stratospheric balloons is studied at DERTS by means of irradiations performed in reals time and simulating the exact flight environment. Two chambers were designed in the laboratory and are described together with the experimental procedure. In order to reduce cost and save time, it is worth accelerating the simulation when only a preliminary evaluation of the sample's properties is required. For this reason, a systematic study was undertaken in order to evaluate the respective effects of different parameters on the material degradation. The results of this study are given [fr

  17. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  18. Percutaneous balloon dilatation for benign hepaticojejunostomy strictures

    NARCIS (Netherlands)

    Vos, P. M.; van Beek, E. J.; Smits, N. J.; Rauws, E. A.; Gouma, D. J.; Reeders, J. W.

    2000-01-01

    BACKGROUND: Percutaneous balloon dilatation of biliary tract strictures is generally accepted as a safe and inexpensive procedure. The effectiveness in selected groups of patients remains under discussion. The purpose of this study was to evaluate the results of percutaneous balloon dilatation in

  19. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  20. Stability of beam-induced tensor pressure tokamaks

    International Nuclear Information System (INIS)

    Cooper, W.A.; Nelson, D.B.; Bateman, G.; Kammash, T.

    1979-10-01

    Necessary and sufficient criteria are obtained for the high toroidal mode number stability of a guiding center plasma in low aspect ratio, D-shaped, beam-induced tensor pressure tokamaks. The difference between the two criteria is significant for interchange stability, while the difference is small for ballooning stability. The critical β value imposed by stability to ballooning modes is higher for perpendicular than for parallel beam injection

  1. Resistive ballooning modes in W7-AS and W7-X

    International Nuclear Information System (INIS)

    Kaiser, R.

    1993-01-01

    'Critical' pressure gradients due to resistive ballooning modes and their growth rates were computed for the W7-AS stellarator and for a HELIAS configuration with W7-X parameters, and the two configurations were compared. The results are based on the evaluation of a fourth order magnetic differential equation along closed magnetic field lines. The numerical procedure applying a variational approach uses the 'Garching resistive ballooning code', GARBO, which was originally developed for the stability analysis of axisymmetric plasmas. Concerning purely growing modes, this analysis shows that the favourable stability properties of W7-X, already optimized with respect to ideal ballooning modes, persist in the resistive regime: the destabilizing effect of resistivity is largely compensated by the stabilizing contribution of plasma compression. As a consequence, the ideal β limit continues only moderately shifted in the resistive case and likewise ideal ballooning stable equilibria (up to β 0 ≅ 5%) do not become resistively unstable. The situation is different for W7-AS. Greater resistive effects (in comparison with W7-X) are found in a configuration that is already ideally much more unstable. A basic feature in resistive calculations is the occurrence of overstable modes. These modes no longer show a stability threshold and, for realistic values of pressure and resistivity, linear instability is obtained for W7-AS as well as for W7-X, with growth rates and oscillation frequencies in the kilo-Hertz range. (author). 29 refs, 13 figs

  2. Trajectory Control For High Altitude Balloons

    Science.gov (United States)

    Aaron, K.; Nock, K.; Heun, M.; Wyszkowski, C.

    We will discuss the continuing development of the StratoSailTM Balloon Trajectory Control System presented at the 33rd COSPAR in 2000. A vertical wing suspended on a 15-km tether from a high altitude balloon uses the difference in wind velocity between the altitude of the balloon and the altitude of the wing to create an aerodynamic sideforce. This sideforce, transmitted to the balloon gondola via the tether, causes the balloon to move laterally. Although the balloon's resultant drift velocity is quite small (a few meters per second), the effect becomes significant over long periods of time (hours to days). Recently, a full-scale wing, rudder and boom assembly has been fabricated, a winch system testbed has been completed, and a lightweight tether with reduced susceptibility to ultraviolet damage has been developed. The development effort for this invention, with pending international patents, has been funded by the NASA/SBIR program in support of the Ultra Long Duration Balloon (ULDB) program.

  3. 14 CFR 61.115 - Balloon rating: Limitations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Balloon rating: Limitations. 61.115 Section... rating: Limitations. (a) If a person who applies for a private pilot certificate with a balloon rating... operate a gas balloon. (b) If a person who applies for a private pilot certificate with a balloon rating...

  4. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  5. Abdominal cavity balloon for preventing a patient's bleeding

    NARCIS (Netherlands)

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po

  6. Optimal patient positioning for ligamentotaxis during balloon kyphoplasty of the thoracolumbar and lumbar spine.

    LENUS (Irish Health Repository)

    Cawley, D T

    2011-06-01

    Percutaneous balloon kyphoplasty aims to restore vertebral height, correct angular deformity and stabilize the spine in the setting of vertebral compression fractures. The patient is positioned prone with supports under the iliac crests and upper thorax to allow gravity to extend the spine. In the treatment of lumbar fractures, we evaluated patient positioning with the contribution of hip extension to increase anterior ligamentotaxis, thus facilitating restoration of vertebral height. Our positioning technique created a mean anterior height increase from 72% to 78% of the average height of the cranial and caudal vertebrae (p=0.037). Balloon inflation did not significantly further increase anterior or posterior vertebral height, or Cobb angle.

  7. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  8. A comparative study of internally and externally capped balloons using small scale test balloons

    Science.gov (United States)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  9. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  10. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  11. Solid State Inflation Balloon Active Deorbiter

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solid State Inflation Balloon (SSIB) is a simple, reliable, low-cost, non-propulsive system for deliberate deorbit and control of downrange point-of-impact that...

  12. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  13. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  14. Significance of balloon pressure recording during angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zollikofer, C.L.; Salomonowitz, E.; Frick, M.P.; Castaneda-Zuniga, W.R.; Amplatz, K.; Bruehlmann, W.F.

    1985-05-01

    During angioplasty of artificial stenoses, atherosclerotic human cadaver arteries, and normal canine arteries, pressure and volume of the dilatation balloons were continuously recorded. We found that a sudden yield of a lesion corresponded to a sudden drop in the pressure curve and an increase of the balloon volume. Volume monitoring was insensitive, but pressure recording was very precise. Continuous pressure recording, using a non-compliant inflation system, correctly demonstrated small breaks and ruptures of atherosclerotic vessels, changes not seen on fluoroscopy.

  15. Theory of ballooning-mirror instabilities for anisotropic pressure plasmas in the magnetosphere

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, C.Z.; Qian, Q.

    1993-09-01

    This paper deals with a kinetic-MHD eigenmode stability analysis of low frequency ballooning-mirror instabilities for anisotropic pressure plasmas in the magnetosphere. The ballooning mode is a dominant transverse wave driven unstable by pressure gradient in the bad curvature region. The mirror mode with a dominant compressional magnetic field perturbation is excited when the product of plasma beta and pressure anisotropy is large. The field-aligned eigenmode equations take into account the coupling of the transverse and compressional components of the perturbed magnetic field and describe the coupled ballooning-mirror mode. Because the energetic trapped ions precess very rapidly across the {rvec B} field, their motion becomes very rigid with respect to low frequency MHD perturbations with symmetric structure of parallel perturbed magnetic field {delta}B{sub {parallel}} and electrostatic potential {Phi} along the north-south ambient magnetic field, and the symmetric ballooning-mirror mode is shown to be stable. On the other hand, the ballooning-mirror mode with antisymmetric {delta}B{sub {parallel}}, and {Phi} structure along the north-south ambient magnetic field is only weakly influenced by energetic trapped particle kinetic effects due to rapid trapped particle bounce motion and has the lowest instability threshold determined by MHD theory. With large plasma beta ({beta}{sub {parallel}} {ge} O(1)) and pressure anisotropy (P{sub {perpendicular}}/P{sub {parallel}} > 1) at equator the antisymmetric ballooning-mirror mode structures resemble the field-aligned wave structures of the multisatellite observations of a long lasting compressional Pc 5 wave event during November 14--15, 1979 [Takahashi et al.]. The study provides the theoretical basis for identifying the internal excitation mechanism of ULF (Pc 4-5) waves by comparing the plasma stability parameters computed from the satellite particle data with the theoretical values.

  16. Assisted coiling of saccular wide-necked unruptured intracranial aneurysms: stent versus balloon.

    Science.gov (United States)

    Consoli, Arturo; Vignoli, Chiara; Renieri, Leonardo; Rosi, Andrea; Chiarotti, Ivano; Nappini, Sergio; Limbucci, Nicola; Mangiafico, Salvatore

    2016-01-01

    Assisted coiling with stents or balloons enables a higher percentage of complete occlusions of saccular unruptured intracranial aneurysms to be achieved with a reasonable complication rate. The aim of this study was to compare stent-assisted coiling and the balloon remodeling technique in terms of efficacy, stability, and safety for the treatment of comparable unruptured saccular intracranial aneurysms. 268 patients with 286 saccular unruptured wide-necked intracranial aneurysms were treated at our institution with stent- or balloon-assisted coiling and retrospectively reviewed. Statistical analysis was performed to assess significant differences between the two groups. The rate of complete occlusion at the end of the procedure was higher with stent-assisted coiling than with balloon-assisted coiling (86.8% vs 78%) and the same results were also observed after 6 months (92.1% vs 77.6%; p=0.05). About 50% of major recurrences occurred in large to giant aneurysms (p<0.001). The overall complication rate was similar in the stent-assisted and balloon-assisted groups (10.3% vs 9.3%). Independently of the technique, a higher complication rate was observed with bifurcational aneurysms, particularly in the middle cerebral artery (p=0.016). Stent-assisted coiling achieved better results in terms of complete occlusion and stability than balloon-assisted coiling with a lower rate of recurrence without being associated with a higher risk of intraprocedural complications. Bifurcational and large to giant aneurysms were associated with higher complication rates and higher recurrence rates, respectively, and still represent a challenge for both techniques. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Payment Platform

    DEFF Research Database (Denmark)

    Hjelholt, Morten; Damsgaard, Jan

    2012-01-01

    Payment transactions through the use of physical coins, bank notes or credit cards have for centuries been the standard formats of exchanging money. Recently online and mobile digital payment platforms has entered the stage as contenders to this position and possibly could penetrate societies...... applies a co-evolutionary multilevel perspective to model the interplay and processes between technology and society wherein digital payment platforms potentially will substitute other payment platforms just like the credit card negated the check. On this basis this paper formulate a multilevel conceptual...... framework and shows, through examples of new digital payment platforms, how transitions and substitutions might occur. Finally we discuss how possible venues and routes of transitions appear in the genesis and evolution of digital payment platforms....

  18. NASA balloon: Aircraft ranging, data and voice experiment

    Science.gov (United States)

    Wishna, S.; Hamby, C.; Reed, D.

    1972-01-01

    A series of tests to evaluate, at L-band, the ranging, voice, and data communications concepts proposed for the air traffic control experiment of the Applications Technology Satellite-F are described. The ground station facilities, balloon platforms and the aircraft were supplied by the European Space Research Organization. One ground simulation and two aircraft flights at low elevation angles were conducted. Even under high interference conditions good performance was obtained for both voice communications and side tone ranging. High bit errors occurred in the data channels resulting in false commands. As a result of the experience gained in operating the equipment in an aircraft environment several recommendations were made for improving the equipment performance.

  19. DLR HABLEG- High Altitude Balloon Launched Experimental Glider

    Science.gov (United States)

    Wlach, S.; Schwarzbauch, M.; Laiacker, M.

    2015-09-01

    The group Flying Robots at the DLR Institute of Robotics and Mechatronics in Oberpfaffenhofen conducts research on solar powered high altitude aircrafts. Due to the high altitude and the almost infinite mission duration, these platforms are also denoted as High Altitude Pseudo-Satellites (HAPS). This paper highlights some aspects of the design, building, integration and testing of a flying experimental platform for high altitudes. This unmanned aircraft, with a wingspan of 3 m and a mass of less than 10 kg, is meant to be launched as a glider from a high altitude balloon in 20 km altitude and shall investigate technologies for future large HAPS platforms. The aerodynamic requirements for high altitude flight included the development of a launch method allowing for a safe transition to horizontal flight from free-fall with low control authority. Due to the harsh environmental conditions in the stratosphere, the integration of electronic components in the airframe is a major effort. For regulatory reasons a reliable and situation dependent flight termination system had to be implemented. In May 2015 a flight campaign was conducted. The mission was a full success demonstrating that stratospheric research flights are feasible with rather small aircrafts.

  20. [Coronary angioplasty using double balloon in artery of large calibre (hugging balloons)].

    Science.gov (United States)

    Centemero, M P; Cano, M N; Maldonado, G; de Almeida, J D; Sousa, A G; Sousa, J E

    1993-07-01

    In this case report the transluminal coronary angioplasty was performed in a oversized right coronary artery with a severe lesion with thrombus inside, using the Hugging balloon technique (two dilatation balloon catheters used simultaneously). This technique achieved minimal residual lesion and had a favorable clinical outcome of the patient.

  1. Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study

    OpenAIRE

    Lages, Frederico Santos; Willya Douglas-de-Oliveira, Dhelfeson; Ibelli, Guilherme Siqueira; Assaf, Fatimah; Queiroz, Thallita Pereira; Costa, Fernando Oliveira

    2017-01-01

    Resonance frequency analysis (RFA) has become the main tool used to assess the osseointegration of dental implants. The objective of this study was to verify the relationship between the ISQ values with different prosthetic abutments and with the implant platform. The hypothesis was that ISQ values changes according to the abutment height. Twelve patients were included, whose contribution to the study was 31 dental implants (external hexagon connection implants, 4.1x10 mm). The temporary impl...

  2. Multiorder etalon sounder (MOES) development and test for balloon experiment

    Science.gov (United States)

    Hays, Paul B.; Wnag, Jinxue; Wu, Jian

    1993-12-01

    concept and laboratory experiments were worked on for the past several years. Both theoretical studies and laboratory prototype experiments showed that MOES is very competitive compared with other high resolution sounders in terms of complexity and performance and has great potential as a compact and rugged high resolution atmospheric temperature and trace species sounder from the polar platform or the geostationary platform. The logical next step is to convert our laboratory prototype to a balloon instrument, so that field test of MOES can be carried out to prove the feasibility and capability of this new technology. Some of the activities related to the development of MOES for a possible balloon flight demonstration are described. Those research activities include the imaging quality study on the CLIO, the design and construction of a MOES laboratory prototype, the test and calibration of the MOES prototype, and the design of the balloon flight gondola.

  3. Lavoisier: A Low Altitude Balloon Network for Probing the Deep Atmosphere and Surface of Venus

    Science.gov (United States)

    Chaasefiere, E.; Berthelier, J. J.; Bertaux, J.-L.; Quemerais, E.; Pommereau, J.-P.; Rannou, P.; Raulin, F.; Coll, P.; Coscia, D.; Jambon, A.; hide

    2005-01-01

    The in-situ exploration of the low atmosphere and surface of Venus is clearly the next step of Venus exploration. Understanding the geochemistry of the low atmosphere, interacting with rocks, and the way the integrated Venus system evolved, under the combined effects of inner planet cooling and intense atmospheric greenhouse, is a major challenge of modern planetology. Due to the dense atmosphere (95 bars at the surface), balloon platforms offer an interesting means to transport and land in-situ measurement instruments. Due to the large Archimede force, a 2 cubic meter He-pressurized balloon floating at 10 km altitude may carry up to 60 kg of payload. LAVOISIER is a project submitted to ESA in 2000, in the follow up and spirit of the balloon deployed at cloud level by the Russian Vega mission in 1986. It is composed of a descent probe, for detailed noble gas and atmosphere composition analysis, and of a network of 3 balloons for geochemical and geophysical investigations at local, regional and global scales.

  4. Atmospheric properties measurements and data collection from a hot-air balloon

    Science.gov (United States)

    Watson, Steven M.; Olson, N.; Dalley, R. P.; Bone, W. J.; Kroutil, Robert T.; Herr, Kenneth C.; Hall, Jeff L.; Schere, G. J.; Polak, M. L.; Wilkerson, Thomas D.; Bodrero, Dennis M.; Borys, R. O.; Lowenthal, D.

    1995-02-01

    Tethered and free-flying manned hot air balloons have been demonstrated as platforms for various atmospheric measurements and remote sensing tasks. We have been performing experiments in these areas since the winter of 1993. These platforms are extremely inexpensive to operate, do not cause disturbances such as prop wash and high airspeeds, and have substantial payload lifting and altitude capabilities. The equipment operated and tested on the balloons included FTIR spectrometers, multi-spectral imaging spectrometer, PM10 Beta attenuation monitor, mid- and far-infrared cameras, a radiometer, video recording equipment, ozone meter, condensation nuclei counter, aerodynamic particle sizer with associated computer equipment, a tethersonde and a 2.9 kW portable generator providing power to the equipment. Carbon monoxide and ozone concentration data and particle concentrations and size distributions were collected as functions of altitude in a wintertime inversion layer at Logan, Utah and summertime conditions in Salt Lake City, Utah and surrounding areas. Various FTIR spectrometers have been flown to characterize chemical plumes emitted from a simulated industrial stack. We also flew the balloon into diesel and fog oil smokes generated by U.S. Army and U.S. Air Force turbine generators to obtain particle size distributions.

  5. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  6. Crash in Australian outback ends NASA ballooning season

    Science.gov (United States)

    Harris, Margaret

    2010-06-01

    NASA has temporarily suspended all its scientific balloon launches after the balloon-borne Nuclear Compton Tele scope (NCT) crashed during take-off, scattering a trail of debris across the remote launch site and overturning a nearby parked car.

  7. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  8. [Intraaortic balloon pumping( IABP) in Japan].

    Science.gov (United States)

    Ono, Tomoyuki; Tanoue, Yoshihisa; Tominaga, Ryuji

    2014-07-01

    The intraaortic balloon pumping (IABP) is the most widely used circulatory assist device. IABP increases coronary perfusion in diastolic phase by the inflation of the balloon in the descending aorta (diastolic augmentation) and reduces afterload in systolic phase by the deflation of the balloon( systolic unloading). IABP improves the hemodynamic condition of patients who fall into acute heart failure and/or cardiogenic shock. Six-type IABP system can be used in Japan. The IABP-SHOCK II trial shows that there is no significant difference in mortality between optimal medical treatment with IABP and without IABP in addition to early revascularization. Clinical backgrounds in Japan are different from those in IABP-SHOCK II trial, and the further prospective studies of IABP in Japan thus called for.

  9. Experimental Validation of a Compound Control Scheme for a Two-Axis Inertially Stabilized Platform with Multi-Sensors in an Unmanned Helicopter-Based Airborne Power Line Inspection System

    Directory of Open Access Journals (Sweden)

    Xiangyang Zhou

    2016-03-01

    Full Text Available A compound control scheme is proposed to achieve high control performance for a two-axis inertially stabilized platform (ISP with multi-sensors applied to an unmanned helicopter (UH-based airborne power line inspection (APLI system. Compared with the traditional two closed-loop control scheme that is composed of a high-bandwidth rate loop and a lower bandwidth position loop, a new current loop inside rate loop is particularly designed to suppress the influences of voltage fluctuation from power supply and motor back electromotive force (BEMF on control precision. In this way, the stabilization accuracy of the ISP is greatly improved. The rate loop, which is the middle one, is used to improve sensor’s stability precision through compensating for various disturbances. To ensure the pointing accuracy of the line of sight (LOS of multi-sensors, the position loop is designed to be the outer one and acts as the main feedback path, by which the accurate pointing angular position is achieved. To validate the scheme, a series of experiments were carried out. The results show that the proposed compound control scheme can achieve reliable control precision and satisfy the requirements of real APLI tasks.

  10. Experimental Validation of a Compound Control Scheme for a Two-Axis Inertially Stabilized Platform with Multi-Sensors in an Unmanned Helicopter-Based Airborne Power Line Inspection System.

    Science.gov (United States)

    Zhou, Xiangyang; Jia, Yuan; Zhao, Qiang; Yu, Ruixia

    2016-03-11

    A compound control scheme is proposed to achieve high control performance for a two-axis inertially stabilized platform (ISP) with multi-sensors applied to an unmanned helicopter (UH)-based airborne power line inspection (APLI) system. Compared with the traditional two closed-loop control scheme that is composed of a high-bandwidth rate loop and a lower bandwidth position loop, a new current loop inside rate loop is particularly designed to suppress the influences of voltage fluctuation from power supply and motor back electromotive force (BEMF) on control precision. In this way, the stabilization accuracy of the ISP is greatly improved. The rate loop, which is the middle one, is used to improve sensor's stability precision through compensating for various disturbances. To ensure the pointing accuracy of the line of sight (LOS) of multi-sensors, the position loop is designed to be the outer one and acts as the main feedback path, by which the accurate pointing angular position is achieved. To validate the scheme, a series of experiments were carried out. The results show that the proposed compound control scheme can achieve reliable control precision and satisfy the requirements of real APLI tasks.

  11. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  12. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  13. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  14. Outcomes of intragastric balloon placements in a private practice setting

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Alders, Peter R. H.; Chuttani, Ram; Scherpenisse, Joost

    2015-01-01

    Intragastric balloons are used as a treatment for obesity. Much of the data collected on balloons has been in the context of clinical trials in academic medical centers or as a bridge to bariatric surgery in obesity centers. The aim of this study was to investigate the efficacy and safety of balloon

  15. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  16. Angry Birds realized: water balloon launcher for teaching projectile motion with drag

    International Nuclear Information System (INIS)

    Edwards, Boyd F; Sam, David D; Christiansen, Michael A; Booth, William A; Jessup, Leslie O

    2014-01-01

    A simple, collapsible design for a large water balloon slingshot launcher features a fully adjustable initial velocity vector and a balanced launch platform. The design facilitates quantitative explorations of the dependence of the balloon range and time of flight on the initial speed, launch angle, and projectile mass, in an environment where quadratic air drag is important. Presented are theory and experiments that characterize this drag, and theory and experiments that characterize the nonlinear elastic energy and hysteresis of the latex tubing used in the slingshot. The experiments can be carried out with inexpensive and readily available tools and materials. The launcher provides an engaging way to teach projectile motion and elastic energy to students of a wide variety of ages. (paper)

  17. Overview Of The Scientific Balloon Activity in Sweden 2014-2016

    Science.gov (United States)

    Abrahamsson, Mattias; Lockowandt, Christian; Andersson, Kent

    2016-07-01

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from Esrange since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times of 4-5 days are very beneficial for astronomical payloads, such as telescopes that need long observation times. Circumpolar flights of more than two weeks are possible if Russian overflight permission exists. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. Since last COSPAR a number of interesting balloon flights have been performed from Esrange. In late 2014 parachute tests for the ExoMars programme was performed by drop-test from balloons. This was followed up on in the summer of 2015 with full end-to-end dynamic stability tests of Earth re-entry capsule shapes. Several balloon

  18. Pseudo-MHD ballooning modes in tokamak plasmas

    International Nuclear Information System (INIS)

    Callen, J.D.; Hegna, C.C.

    1996-08-01

    The MHD description of a plasma is extended to allow electrons to have both fluid-like and adiabatic-regime responses within an instability eigenmode. In the resultant open-quotes pseudo-MHDclose quotes model, magnetic field line bending is reduced in the adiabatic electron regime. This makes possible a new class of ballooning-type, long parallel extent, MHD-like instabilities in tokamak plasmas for α > s 2 (2 7/3 /9) (r p /R 0 ) or-d√Β/dr > (2 1/6 /3)(s/ R 0q ), which is well below the ideal-MHD stability boundary. The marginally stable pressure profile is similar in both magnitude and shape to that observed in ohmically heated tokamak plasmas

  19. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  20. Payment Platform

    DEFF Research Database (Denmark)

    Hjelholt, Morten; Damsgaard, Jan

    2012-01-01

    Payment transactions through the use of physical coins, bank notes or credit cards have for centuries been the standard formats of exchanging money. Recently online and mobile digital payment platforms has entered the stage as contenders to this position and possibly could penetrate societies...

  1. Platform computing

    CERN Multimedia

    2002-01-01

    "Platform Computing releases first grid-enabled workload management solution for IBM eServer Intel and UNIX high performance computing clusters. This Out-of-the-box solution maximizes the performance and capability of applications on IBM HPC clusters" (1/2 page) .

  2. Influence of Equilibrium Perpendicular Shear Flow on Peeling-ballooning Instabilities

    Science.gov (United States)

    Xi, P. W.; Xu, X. Q.

    2011-10-01

    The influence of perpendicular ExB shear flow on peeling-ballooning instabilities is investigated with BOUT++ code. In our simulation, a set of reduced MHD equations are solved for a very unstable equilibrium and a marginal unstable equilibrium in shifted-circular tokamak geometry. For ideal MHD cases without diamagnetic terms and resistivity, we find that flow shear shows dramatic stabilizing effect on peeling-ballooning modes and the stabilizing degree increases with mode number. When the flow shear is large enough, we find the curvature of growth rate verse mode number has the same shape like that for the case with only diamagnetic term, and this implies that diamagnetic term and the shear flow have the same mechanism acting on peeling-ballooning instabilities. The role of Kelvin-Helmholtz term is also investigated and we find it is destabilizing and the effect depends on both flow shear and mode number. For cases with both diamagnetic term and the applied shear flow, modes with intermediate mode number are strongest stabilized while high n and low n mode keep unstable. Based on these results, an ELM trigger sketch is proposed. Performed for USDoE by LLNL Contract DE-AC52-07NA27344.

  3. Temporary balloon occlusion as therapy for uncontrollable arterial hemorrhage in multiply injured patients

    International Nuclear Information System (INIS)

    Rieger, J.; Linsenmaier, U.; Rock, C.; Pfeifer, K.J.; Euler, E.

    1999-01-01

    Purpose: Presentation of temporary balloon occlusion as an interventional radiological method for managing hemorrhage in multiply injured patients with uncontrollable loss of blood. Method: Temporary, non-selective arterial occlusion by introduction of a balloon catheter contralaterally to the source of bleeding has been performed since 1992 on 7 patients with multiple injuries, hemorrhagic shock requiring reanimation, and angiographic demonstration of an arterial hemorrhage in the supply region of the internal iliac artery with complex pelvic fracture. In each case a PTA balloon catheter was introduced transfemorally, non-selectively positioned proximal to the bleeding source, and left in place for 24-48 h under manometric control. Control angiographies were performed prior to catheter removal. Results: The bleeding was stopped immediately in all 7 patients. The hemodynamic stability made transport and thus further surgical management and/or a short-term treatment in the intensive-care station possible. Control angiographies confirmed that the bleeding had stopped in all patients. Conclusions: We recommend temporary balloon occlusion as a rapid and effective method for the management of bleeding in otherwise uncontrollable traumatic hemorrhages in the supply region of the internal iliac artery. (orig.) [de

  4. Coordinated weather balloon solar radiation measurements during a solar eclipse.

    Science.gov (United States)

    Harrison, R G; Marlton, G J; Williams, P D; Nicoll, K A

    2016-09-28

    Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Authors.

  5. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Han, Joon Koo; Park, Jae Hyung

    1993-01-01

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  6. Low dose intravaginal misoprostol versus intracervical balloon ...

    African Journals Online (AJOL)

    Background:The efficacy and safety of low dose misoprostol as a ripening agent compared to the widely used balloon catheter in developing countries is undetermined. Objective:To compare the safety and efficacy of a low dose intravaginal misoprostol and intracervical Foley's catheter for cervical ripening. Design:A ...

  7. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...

  8. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    Science.gov (United States)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  9. Effects of Early Moderate Loading on Implant Stability: A Retrospective Investigation of 634 Implants with Platform Switching and Morse-Tapered Connections.

    Science.gov (United States)

    Romanos, Georgios; Grizas, Eleftherios; Laukart, Elena; Nentwig, Georg-Hubertus

    2016-04-01

    This retrospective investigation aimed to evaluate the effect of early moderate loading (EML) on implant stability. Following 6 weeks of conventional healing, 634 dental implants (Ankylos®, Dentsply Implants, Mannheim, Germany) inserted in 247 patients were uncovered. Provisional restorations were placed in infra-occlusion in partially edentulous patients and in full occlusion in edentulous patients. Patients were instructed to consume a soft/liquid diet until final restorations were delivered after approximately 6 weeks. Periotest values (PTVs) at the time of uncovering and after EML were assessed in order to calculate the change in PTV (ΔPTV). Improvement of the PTV was analyzed to account for dependencies between measurements on multiple implants of a single patient, along with other factors. No implant was lost during the EML. After a mean loading time of 3 years (± 1.7 years), the implant survival rate was 98.74%. The PTV of 556 implants decreased (improved) over the course of the study. The ΔPTV was statistically significant (p = .0001), and none of the factors analyzed appeared to influence it. The EML of implants does not impair the implants' stability, as determined by Periotest. On the contrary, early moderate loading seems to be beneficial at compromised bone qualities. © 2015 Wiley Periodicals, Inc.

  10. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  11. ITS Platform

    DEFF Research Database (Denmark)

    Tøfting, Svend; Lahrmann, Harry; Agerholm, Niels

    2014-01-01

    for safer and more economic driving is technologically possible. Big Data from the system can provide traffic authorities with a better basis for decision for their traffic planning. Last, but not least, it is possible to establish payment systems. The project has also shown that the boxes in the cars do...... GPS box with data connection to a backend server. The ITS Platform project has had a budget of DKK 33 million (app € 4.4) and it has demonstrated that boxes which register the position of the cars can be helpful to drivers in many ways. Establishing dynamic traffic information and support systems...... not have to be very intelligent. This is gradually taken over by applications on smart phones. The ITS Platform with 425 test drivers is now completely developed and can be used for technological testing of e.g. payment systems....

  12. Magnetohydrodynamic stability of tokamaks

    CERN Document Server

    Zohm, Hartmut

    2014-01-01

    This book bridges the gap between general plasma physics lectures and the real world problems in MHD stability. In order to support the understanding of concepts and their implication, it refers to real world problems such as toroidal mode coupling or nonlinear evolution in a conceptual and phenomenological approach. Detailed mathematical treatment will involve classical linear stability analysis and an outline of more recent concepts such as the ballooning formalism. The book is based on lectures that the author has given to Master and PhD students in Fusion Plasma Physics. Due its strong lin

  13. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  14. ELMs and constraints on the H-mode pedestal: A model based on peeling-ballooning modes

    International Nuclear Information System (INIS)

    Snyder, P.B.; Ferron, J.R.; Wilson, H.R.

    2003-01-01

    We propose a model for Edge Localized Modes (ELMs) and pedestal constraint based upon theoretical analysis of instabilities which can limit the pedestal height and drive ELMs. The sharp pressure gradients, and resulting bootstrap current, in the pedestal region provide free energy to drive peeling and ballooning modes. The interaction of peeling-ballooning coupling, ballooning mode second stability, and finite-Larmor-radius effects results in coupled peeling-ballooning modes of intermediate wavelength generally being the limiting instability. A highly efficient new MHD code, ELITE, is used to calculate quantitative stability constraints on the pedestal, including con straits on the pedestal height. Because of the impact of collisionality on the bootstrap current, these pedestal constraints are dependant on the density and temperature separately, rather than simply on the pressure. A model of various ELM types is developed, and quantitatively compared to data. A number of observations agree with predictions, including ELM onset times, ELM depth and variation in pedestal height with collisionality and discharge shape. Stability analysis of series of model equilibria are used both o predict and interpret pedestal trends in existing experiments and to project pedestal constraints for future burning plasma tokamak designs. (author)

  15. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  16. User's manual for the FLORA equilibrium and stability code

    International Nuclear Information System (INIS)

    Freis, R.P.; Cohen, B.I.

    1985-01-01

    This document provides a user's guide to the content and use of the two-dimensional axisymmetric equilibrium and stability code FLORA. FLORA addresses the low-frequency MHD stability of long-thin axisymmetric tandem mirror systems with finite pressure and finite-larmor-radius effects. FLORA solves an initial-value problem for interchange, rotational, and ballooning stability

  17. Evolution of scientific ballooning and its impact on astrophysics research

    Science.gov (United States)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  18. Peeling-Ballooning Mode Analysis in Shifted-Circle Tokamak Equilibria

    Science.gov (United States)

    Burke, B.; Kruger, S. E.; Hegna, C. C.; Snyder, P. B.; Sovinec, C. R.; Zhu, P.

    2009-11-01

    Progress in understanding edge localized modes (ELMs) has been made by investigating the stability properties of edge localized peeling-ballooning modes. We focus on the evolution of ideal MHD modes over a large spectrum in two shifted-circle tokamak equilibria, using the extended-MHD code NIMROD. The TOQ-generated equilibria model a H-mode plasma with a pedestal pressure profile and parallel edge currents. A vacuum region is prescribed by a resistivity profile that transitions from a small to very large value at a specified location. The vacuum model is benchmarked against the linear ideal MHD codes ELITE & GATO. We demonstrate vacuum effects on the stability by adjusting the vacuum location relative to the pedestal pressure region. Ballooning-like instabilities dominate distant vacuum cases, whereas peeling mode physics is expected to dominate as the vacuum approaches the pedestal. Numerical simulations of the early nonlinear stages of edge localized MHD instabilities are presented. Comparisons between equilibria that have ``ballooning'' dominated instabilities relative to equilibria that are ``peeling'' dominated are made.

  19. Retrograde prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    The authors performed retrograde prostatic urethroplasty in 18 patients using a 25-mm urethroplasty balloon catheter. The procedure was performed on an outpatient basis under local anesthesia. Voiding cystourethrography, retrograde urethrography, rectal US, and MRE imaging were performed before and immediately after the procedure and at 2 weeks and 3, 6, 12, and 18 months. Long-term results at 18 months and possible clinical implications are discussed

  20. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  1. Intragastric balloon for treatment-resistant obesity: safety, tolerance, and efficacy of 1-year balloon treatment followed by a 1-year balloon-free follow-up

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Tytgat, Guido N. J.

    2005-01-01

    Background: Prior efforts to treat obesity with intragastric balloons were thwarted by high complication rates. Therefore, fundamental requirements for optimal balloon designs were defined. The aim of the present study was to investigate the effectiveness, the safety; and the tolerance of a new

  2. Theory of energetic trapped particle-induced resistive interchange-ballooning modes

    International Nuclear Information System (INIS)

    Biglari, H.; Chen, L.

    1986-02-01

    A theory describing the influence of energetic trapped particles on resistive interchange-ballooning modes in tokamaks is presented. It is shown that a population of hot particles trapped in the region of adverse curvature can resonantly interact with and destabilize the resistive interchange mode, which is stable in their absence because of favorable average curvature. The mode is different from the usual resistive interchange mode not only in its destabilization mechanism, but also in that it has a real component to its frequency comparable to the precessional drift frequency of the rapidly circulating energetic species. Corresponding growth rate and threshold conditions for this trapped-particle-driven instability are derived and finite banana width effects are shown to have a stabilizing effect on the mode. Finally, the ballooning/tearing dispersion relation is generalized to include hot particles, so that both the ideal and the resistive modes are derivable in the appropriate limits. 23 refs., 7 figs

  3. Large deformation and mechanics of flexible isotropic membrane ballooning in three dimensions by differential quadrature method

    International Nuclear Information System (INIS)

    Mozaffari, M.; Atai, A. A.; Mostafa, N.

    2009-01-01

    This paper presents a computationally efficient and accurate new methodology in the differential quadrature analysis of structural mechanics for flexible membranes ballooning in three dimensions under a negative air pressure differential. The differential quadrature method is employed to discretize the resulting equations in the axial direction as well as for the solution procedure. The weighting coefficients employed are not exclusive, and any accurate and efficient method such as the generalized differential quadrature method may be used to produce the methods weighting coefficients. A second-order paraboloid of revolution is assumed to describe the ballooning shape. This study asserts the accuracy, convergency, and efficiency of the methodology by solving some typical stability, straining analysis membrane problems, and comparing the results with those of the exact solutions and/or those of physical tests

  4. Large deformation and mechanics of flexible isotropic membrane ballooning in three dimensions by differential quadrature method

    Energy Technology Data Exchange (ETDEWEB)

    Mozaffari, M.; Atai, A. A.; Mostafa, N. [Islamic Azad University, Karaj (Iran, Islamic Republic of)

    2009-11-15

    This paper presents a computationally efficient and accurate new methodology in the differential quadrature analysis of structural mechanics for flexible membranes ballooning in three dimensions under a negative air pressure differential. The differential quadrature method is employed to discretize the resulting equations in the axial direction as well as for the solution procedure. The weighting coefficients employed are not exclusive, and any accurate and efficient method such as the generalized differential quadrature method may be used to produce the methods weighting coefficients. A second-order paraboloid of revolution is assumed to describe the ballooning shape. This study asserts the accuracy, convergency, and efficiency of the methodology by solving some typical stability, straining analysis membrane problems, and comparing the results with those of the exact solutions and/or those of physical tests

  5. Kinetic analysis of MHD ballooning modes in tokamaks

    International Nuclear Information System (INIS)

    Tang, W.M.; Rewoldt, G.; Cheng, C.Z.; Chance, M.S.

    1984-10-01

    A comprehensive analysis of the stability properties of the appropriate kinetically generalized form of MHD ballooning modes together with the usual trapped-particle drift modes is presented. The calculations are fully electromagnetic and include the complete dynamics associated with compressional ion acoustic waves. Trapped-particle effects along with all forms of collisionless dissipation are taken into account without approximations. The influence of collisions is estimated with a model Krook operator. Results from the application of this analysis to realistic tokamak operating conditions indicate that unstable short-wavelength modes with significant growth rates can extend from β = 0 to value above the upper ideal-MHD-critical-beta associated with the so-called second stability regime. Since the strength of the relevant modes appears to vary gradually with β, these results support a soft beta limit picture involving a continuous (rather than abrupt or hard) modification of anomalous transport already present in low-β-tokamaks. However, at higher beta the increasing dominance of the electromagnetic component of the perturbations indicated by these calculations could also imply significantly different transport scaling properties

  6. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  7. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  8. Numerical modeling of the 2017 active seismic infrasound balloon experiment

    Science.gov (United States)

    Brissaud, Q.; Komjathy, A.; Garcia, R.; Cutts, J. A.; Pauken, M.; Krishnamoorthy, S.; Mimoun, D.; Jackson, J. M.; Lai, V. H.; Kedar, S.; Levillain, E.

    2017-12-01

    We have developed a numerical tool to propagate acoustic and gravity waves in a coupled solid-fluid medium with topography. It is a hybrid method between a continuous Galerkin and a discontinuous Galerkin method that accounts for non-linear atmospheric waves, visco-elastic waves and topography. We apply this method to a recent experiment that took place in the Nevada desert to study acoustic waves from seismic events. This experiment, developed by JPL and its partners, wants to demonstrate the viability of a new approach to probe seismic-induced acoustic waves from a balloon platform. To the best of our knowledge, this could be the only way, for planetary missions, to perform tomography when one faces challenging surface conditions, with high pressure and temperature (e.g. Venus), and thus when it is impossible to use conventional electronics routinely employed on Earth. To fully demonstrate the effectiveness of such a technique one should also be able to reconstruct the observed signals from numerical modeling. To model the seismic hammer experiment and the subsequent acoustic wave propagation, we rely on a subsurface seismic model constructed from the seismometers measurements during the 2017 Nevada experiment and an atmospheric model built from meteorological data. The source is considered as a Gaussian point source located at the surface. Comparison between the numerical modeling and the experimental data could help future mission designs and provide great insights into the planet's interior structure.

  9. Stabilisation problem in biaxial platform

    Science.gov (United States)

    Lindner, Tymoteusz; Rybarczyk, Dominik; Wyrwał, Daniel

    2016-12-01

    The article describes investigation of rolling ball stabilization problem on a biaxial platform. The aim of the control system proposed here is to stabilize ball moving on a plane in equilibrium point. The authors proposed a control algorithm based on cascade PID and they compared it with another control method. The article shows the results of the accuracy of ball stabilization and influence of applied filter on the signal waveform. The application used to detect the ball position measured by digital camera has been written using a cross platform .Net wrapper to the OpenCV image processing library - EmguCV. The authors used the bipolar stepper motor with dedicated electronic controller. The data between the computer and the designed controller are sent with use of the RS232 standard. The control stand is based on ATmega series microcontroller.

  10. Stabilisation problem in biaxial platform

    Directory of Open Access Journals (Sweden)

    Lindner Tymoteusz

    2016-12-01

    Full Text Available The article describes investigation of rolling ball stabilization problem on a biaxial platform. The aim of the control system proposed here is to stabilize ball moving on a plane in equilibrium point. The authors proposed a control algorithm based on cascade PID and they compared it with another control method. The article shows the results of the accuracy of ball stabilization and influence of applied filter on the signal waveform. The application used to detect the ball position measured by digital camera has been written using a cross platform .Net wrapper to the OpenCV image processing library - EmguCV. The authors used the bipolar stepper motor with dedicated electronic controller. The data between the computer and the designed controller are sent with use of the RS232 standard. The control stand is based on ATmega series microcontroller.

  11. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  12. Advanced Li batteries for terrestrial balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — For future advanced terrestrial balloon missions, NASA requires energy dense and power dense energy storage solutions significantly exceeding the performance of...

  13. Hyperspectral Polarimeter for Monitoring Balloon Strain, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  14. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  15. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with

  16. Ballooning modes in the ELMO Bumpy Square configuration using the generalized kinetic energy principle

    International Nuclear Information System (INIS)

    Spong, D.A.

    1984-01-01

    In the bumpy square configuration, toroidal curvature is localized in the corner sections rather than uniformly distributed, as is the case in the existing circular ELMO Bumpy Torus (EBT) configuration. This feature, coupled with the fact that the magnetic field is higher in the corner sections, results in a number of distinct advantages with respect to particle confinement, heating, and transport. It might be expected, however, that ballooning modes should have some tendency to concentrate in the corner sections - especially along the outer field lines where the curvature and pressure gradients are unfavorable. Here we examine the stability of such a configuration using a ballooning mode equation derived from the generalized kinetic energy principle. The side and corner sections of the square are treated with a piecewise constant approximation and matched at a transition boundary to obtain the stability condition. This retains the ring-core coupling and yields both the low β/sub c/ diamagnetic well stabilization condition and a high-β/sub c/ stability limit analogous to the Lee-Van Dam-Nelson β/sub c/ limit, where β/sub c/ is the core plasma beta. Due to the high magnetic field in the corners and the relatively weak curvature there (approx. = 1/2 of the curvaure in the bumpy sections), this upper β/sub c/ limit is not significantly changed from that which would be present in the conventional circular bumpy torus configuration

  17. Influence of hot beam ions on MHD ballooning modes in tokamaks

    International Nuclear Information System (INIS)

    Rewoldt, G.; Tang, W.M.

    1984-07-01

    It has recently been proposed that the presence of high energy ions from neutral beam injection can have a strong stabilizing effect on kinetically-modified ideal MHD ballooning modes in tokamaks. In order to assess realistically the importance of such effects, a comprehensive kinetic stability analysis, which takes into account the integral equation nature of the basic problem, has been applied to this investigation. In the collisionless limit, the effect of adding small fractions of hot beam ions is indeed found to be strongly stabilizing. On the other hand, for somewhat larger fractions of hot ions, a new beam-driven mode is found to occur with a growth rate comparable in magnitude to the growth rate of the MHD ballooning mode in the absence of hot ions. This implies that there should be an optimal density of hot particles which minimizes the strength of the relevant instabilities. Employing non-Maxwellian equilibrium distribution functions to model the beam species makes a quantitative, but not qualitative, difference in the results. Adding collisions to the calculation tends to reduce considerably the stabilizing effect of the hot ions

  18. Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

    Science.gov (United States)

    Strikwerda, S; van Swijndregt, E M; Melkert, R; Serruys, P W

    1995-02-01

    Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone. Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone. A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain. Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean +/- SD) 0.73 +/- 0.44 and 0.74 +/- 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 +/- 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 +/- 0.35 and 2.56 +/- 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 +/- 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 +/- 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 +/- 0.52 and 1.00 +/- 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 +/- 0.35 and 1.75 +/- 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%. In matched groups of successfully treated

  19. The Balloon-borne Large Aperture Telescope for Polarization - BLASTPol

    Science.gov (United States)

    Devlin, Mark

    We are proposing a comprehensive program to study the link between Galactic magnetic fields and star formation. After decades of study, the physical processes regulating star formation still remain poorly understood. Large-scale observations of star forming regions provide counts of the number of dense clouds each of which will eventually evolve into tens to hundreds of stars. However, when simple models of gravitational collapse are applied to the clouds they yield a Galactic star formation rate (SFR) which is many times what is actually observed. Some process or combination of processes must be slowing the collapse of the clouds. The two prevailing theories involve turbulence which prevents the effective dissipation of energy and Galactic magnetic fields which are captured and squeezed by the collapsing cloud provide a mechanism for mechanical support. Understanding these effects fits very well the SMD 2010 Science Plan's Cosmic Origins program. The Balloon-borne Large Aperture Telescope - BLAST was originally designed to conduct confusion-limited and wide-area extragalactic and Galactic surveys at submillimeter wavelengths from a long-duration balloon (LDB) platform. These wavelengths are impossible or very difficult to observe from even the best groundbased telescope sites. After a series of successful flights (Ft. Sumner 2003, Sweden 2005, and Antarctica 2006) resulting in over 25 publications, BLAST was converted to BLASTPol. The combination of a polarizing grid in front of each of the 266 feed horns at 250, 350 and 500 micron with a stepped Half Wave Plate (HWP) provided a quick and inexpensive way to make initial measurements of polarized dust emission in star forming regions. By mapping polarization from dust grains aligned with respect to their local magnetic field, the field orientation (projected on the sky) can be traced. The development of the Next Generation BLASTPol instrument is now complete. It has increased spatial resolution (22 arcseconds at

  20. Anatomical landmarks for safely implementing resuscitative balloon occlusion of the aorta (REBOA) in zone 1 without fluoroscopy.

    Science.gov (United States)

    Okada, Yohei; Narumiya, Hiromichi; Ishi, Wataru; Iiduka, Ryoji

    2017-07-03

    Resuscitative balloon occlusion of the aorta (REBOA) can maintain hemodynamic stability during hemorrhagic shock after a following torso injury, although inappropriate balloon placement may induce brain or visceral organ ischemia. External anatomical landmarks [the suprasternal notch (SSN) and xiphoid process (Xi)] are empirically used to implement REBOA in zone 1. We aimed to confirm if these landmarks were useful for determining a balloon catheter length for safe implementation of REBOA in zone 1 without using fluoroscopy. We selected 25 successive adult blunt trauma cases requiring contrast-enhanced chest/abdominal computed tomography (CT) treated at our emergency department (in an urban area of Kyoto city, Japan) between October 1, 2016 and January 31, 2017. We retrospectively evaluated anonymized CT images. We used three-dimensional multiplanar reconstructions to measure the length along the aorta's central axis, from the bilateral common femoral arteries (FA) to the celiac trunk (CeT) (FA-CeT) and to the origin of the left subclavian artery (LSCA) (FA-LSCA). Volume-rendering reconstruction images were used to measure the external distance from common FAs to SSN (FA-SSN) and to Xi (FA-Xi). FA-LSCA was significantly longer than FA-SSN. FA-CeT was significantly shorter than FA-Xi. Based on these results, the REBOA balloon catheter should be shorter than FA-SSN, and longer than FA-Xi to avoid placement outside zone 1. The advantages of this method are that it can rapidly and easily predict a safe balloon catheter length, and it reflects each patient's individual torso height. To safely implement REBOA, the balloon catheter length should be shorter than FA-SSN and longer than FA-Xi. We believe that these anatomical landmarks are good references for safe implementation of REBOA in zone 1 without radiographic guidance.

  1. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  2. Retrograde transurethral balloon dilation of the prostate

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Wasserman, N.F.; Lund, G.; Hulbert, J.; Hunter, D.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1986-01-01

    A series of patients with documented benign prostatic hypertrophy evaluated by urodynamic studies, voiding cystourethrography, retrograde urethrography, and MR imaging underwent dilation performed using a retrograde transurethral approach with 25-mm balloon dilators inflated at a pressure of 3-4 atm for 10 minutes. Immediately after the procedure, retrograde and voiding cystourethrography as well as MR imaging were performed. A Foley catheter was left in place for 24 hours. Complete relief of symptoms has occurred in all of the patients during the follow-up period. No significant complications other than transient hematuria resulted from the procedure. Results of the comparison studies and of MR imaging are discussed

  3. Station-keeping of a high-altitude balloon with electric propulsion and wireless power transmission: A concept study

    Science.gov (United States)

    van Wynsberghe, Erinn; Turak, Ayse

    2016-11-01

    A stable, ultra long-duration high-altitude balloon (HAB) platform which can maintain stationary position would represent a new paradigm for telecommunications and high-altitude observation and transmission services, with greatly reduced cost and complexity compared to existing technologies including satellites, telecom towers, and unmanned aerial vehicles (UAVs). This contribution proposes a lightweight superpressure balloon platform for deployment to an altitude of 25 km. Electrohydrodynamic (EHD) thrusters are presented to maintain position by overcoming stratospheric winds. Critical to maintaining position is a continual supply of electrical power to operate the on-board propulsion system. One viable solution is to deliver power wirelessly to a high-altitude craft from a ground-based transmitter. Microwave energy, not heavily attenuated by the atmosphere, can be provided remotely from a ground-based generator (magnetron, klystron, etc.) and steered electrically with an antenna array (phased array) at a designated frequency (such as 2.45 or 5.8 GHz). A rectifying antenna ("rectenna") on the bottom of the balloon converts waves into direct current for on-board use. Preliminary mission architecture, energy requirements, and safety concerns for a proposed system are presented along with recommended future work.

  4. Endoscopic Papillary Balloon Dilation with Large Balloon after Limited Sphincterotomy for Retrieval of Choledocholithiasis

    Science.gov (United States)

    Bang, Seungmin; Kim, Myoung Hwan; Park, Jeong Youp; Park, Seung Woo; Song, Si Young

    2006-01-01

    Endoscopic papillary balloon dilation (EBD) for choledocholithiasis is known to be comparable to endoscopic sphincterotomy (EST) especially in cases of small stones. With larger stones, EBD with conventional balloon, which have a diameter of 6-8 mm, was reported as less effective for extraction of stones. We evaluated the efficacy and complications of EBD with large balloons (10-15 mm) after limited EST for retrieval of choledocholithiasis. From February 2005, we have performed EBD with limited EST for retrieval of common bile duct (CBD) stones. The patients who admitted with hyperamylasemia and gallstone pancreatitis were excluded. In cases without CBD dilation, EPBD with 12 mm for 40 seconds was performed. And in cases with CBD dilation, we dilated the sphincters with 15 mm sized balloon for 40 seconds. Total 22 patients (11 of male) were performed EBD with limited EST for retrieval of CBD stones. The median diameter of the stones was 10 mm (5-25 mm). Ten cases had multiple stones and 6 cases periampullary diverticuli. Successful stone removal in the initial session of ERCP with EBD was accomplished in 16 patients (72.7%). And complete retrieval of bile duct stones was achieved in all patients with repeated ERCP. In the aspect of complications, any episodes of perforation, bleeding was not developed. Only one case of mild grade of post-procedural pancreatitis was noted. However, post-procedural hyperamylasemia was developed in 16 cases (68.2%). EBD with larger balloon seems to be a feasible and safe alternative technique for conventional EST in CBD stone extraction. PMID:17191309

  5. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. The Evaluation of Endoscopic Balloon Dilation Treatment for

    Directory of Open Access Journals (Sweden)

    Shokri-Shirvani Javad

    2009-10-01

    Full Text Available Balloon dilatation of stricture is one of the new treatment methods among patients with gastric outlet obstruction (GOO. However, the prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that would affect its success rate patients with benign etiology for GOO. Forty-five patients with the symptoms of benign GOO were randomly selected. Gastric outlet was delineated using double channel videoendoscopy. The information of initial balloon dilation was collected from recorded files. Balloon dilatation was repeated during the mean follow up of 9.9 ± 5.8 months. The severity of gastric pain was measured immediately before balloon dilatation and one month after procedure and was rated on a 10 cm visual analogue scale. The mean age of patients was 43.7 ± 18.1 years and 86.7% of them were men. Furthermore, 71.1% were H pylori positive. Response rate to endoscopic balloon dilatation was 80% and 8 patients underwent surgical resection. Weight loss was more frequent in non-responding group. The pain severity was significantly reduced more in responding subjects. No meaningful relationships were found between the responses to balloon dilatation and positive H pylori and cigarette smoking. Endoscopic balloon dilation is safe and effective for most patients with benign gastric outlet obstruction and has favorable long-term outcome.

  7. The Balloon Foot ; A Rare Presentation Of Congenital Constricting ...

    African Journals Online (AJOL)

    We present a case of a rare manifestation of congenital constricting annular band (CAB) in the lower extremity resulting in a severe excessive swelling of the foot which we have termed Balloon foot. The ballooned foot is caused by a progressive deepening of the circumferential constriction into the soft tissue of the lower ...

  8. Scientific ballooning in the 20 th century; a historical perspective

    Science.gov (United States)

    Nishimura, J.

    Hess discovered the cosmic rays in 1912. Using a manned balloon, he found the altitude variation of the radiation. After this discovery, many balloon experiments were performed to explore the most mysterious radiation coming from outside of the earth during the 1920's to the 1930's. At the end of the 1940's, balloon systems were revolutionized by the use of new plastic films and telemetry systems. At almost the same time, highly sensitive nuclear emulsions were developed. Balloon exposures of emulsions brought us new discoveries of the heavy primaries in cosmic rays. Extensive studies with nuclear emulsions discovered high-energy phenomena and new particles between the end of 1940's to the 1960's. At the same time, in various countries, experiments with more sophisticated electronic devices were begun together with ingenious work on balloon technology. Inventions were made in the areas of designing, manufacturing, materials, telemetry systems for balloons and long duration flight systems etc. Several permanent launching stations were established in various countries in the 1960's Here, I review the development of essential technologies in scientific ballooning, and their value in contributing to the growth of space physics. As the future prospect, I stress the point that scientific ballooning is indispensable and a most cost-effective way to explore space astrophysics and Earth science, in addition to the preparation of satellite and the space station experiments.

  9. Coronary artery angioplasty with a helical autoperfusion balloon catheter

    NARCIS (Netherlands)

    Gurbel, PA; Anderson, RD; vanBoven, AJ; denHeijer, P

    The initial in-hospital and long-term clinical experience with a helical autoperfusion balloon catheter in the treatment of coronary artery disease is reported, This new catheter design allows blood to flow passively around the inflated balloon through a protected helical channel molded into the

  10. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  11. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  12. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    Dewar, R.L.

    1997-01-01

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θ k is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θ k

  13. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  14. Development and in Vitro Characterization of Photochemically Crosslinked Polyvinylpyrrolidone Coatings for Drug-Coated Balloons

    Directory of Open Access Journals (Sweden)

    Svea Petersen

    2013-12-01

    Full Text Available Polyvinylpyrrolidone (PVP is a conventionally applied hydrophilic lubricious coating on catheter-based cardiovascular devices, used in order to ease movement through the vasculature. Its use as drug reservoir and transfer agent on drug-coated balloons (DCB is therefore extremely promising with regard to the simplification of its approval as a medical device. Here, we developed a PVP-based coating for DCB, containing paclitaxel (PTX as a model drug, and studied the impact of crosslinking via UV radiation on drug stability, wash off, and transfer during simulated use in an in vitro vessel model. We showed that crosslinking was essential for coating stability and needed to be performed prior to PTX incorporation due to decreased drug bioavailability as a result of photodecomposition and/or involvement in vinylic polymerization with PVP under UV radiation. Moreover, the crosslinking time needed to be carefully controlled. While short radiation times did not provide enough coating stability, associated with high wash off rates during DCB insertion, long radiation times lowered drug transfer efficiency upon balloon expansion. A ten minutes radiation of PVP, however, combined a minimized drug wash off rate of 34% with an efficient drug transfer of 49%, underlining the high potential of photochemically crosslinked PVP as a coating matrix for DCB.

  15. Ideal Magnetohydrodynamic Stability of the NCSX

    International Nuclear Information System (INIS)

    Fu, Guo Yong; Isaev, Maxim Yu; Ku, Long-Poe; Mikhailov, M.; Redi, M.H; Sanchez, Raul; Subbotin, A; Hirshman, Steven Paul; Cooper, W. Anthony; Monticello, D.; Reiman, A.H.; Zarnstorff, M.C.

    2007-01-01

    The ideal magnetohydrodynamic (MHD) stability of the National Compact Stellarator Experiment (NCSX) is extensively analyzed using the most advanced three-dimensional MHD codes. It is shown that the NCSX is stable to finite-n MHD modes, including the vertical mode, external kink modes and ballooning modes. However, high-n external kink modes that peak near the plasma edge are found to be weakly unstable. A global calculation shows that finite-n ballooning modes are significantly more stable than the local infinite-n modes

  16. Rapid Development of Bespoke Unmanned Platforms for Atmospheric Science

    Science.gov (United States)

    Sobester, A.; Johnston, S. J.; Scanlan, J. P.; Hart, E. E.; O'Brien, N. S.

    2012-04-01

    The effective deployment of airborne atmospheric science instruments often hinges on the development cycle time of a suitable platform, one that is capable of delivering them to the desired altitude range for a specified amount of time, along a pre-determined trajectory. This could be driven by the need to respond rapidly to sudden, unexpected events (e.g., volcano eruptions, nuclear fallout, etc.) or simply to accommodate the iterative design and flight test cycle of the instrument developer. A shorter development cycle time would also afford us the ability to quickly adapt the hardware and control logic in response to unexpected results during an experimental campaign. We report on recent developments aimed at meeting this demand. As part of the Atmospheric Science Through Robotic Aircraft (ASTRA) initiative we have investigated the use of rapid prototyping technologies to this end, both on the 'airframe' of the platform itself and on the on-board systems. We show how fast multi-disciplinary design optimization techniques, coupled with computer-controlled additive manufacturing (3D printing) and laser cutting methods and electronic prototyping (using standard, modular, programmable building blocks) can lead to the delivery of a fully customized platform integrating a given instrument in a timescale of the order of ten days. Specific examples include the design and testing of a balloon-launched glider sensorcraft and a stratospheric balloon system. The 'vehicle' for the latter was built on a 3D printer using a copolymer thermoplastic material and fitted with a sacrificial protective 'cage' laser-cut from an open-cell foam. The data logging, tracking, sensor integration and communications services of the platform were constructed using the .net Gadgeteer open source hardware kit. The flight planning and eventual post-flight recovery of the system is enabled by a generic, stochastic trajectory simulation tool, also developed as part of the ASTRA initiative. This

  17. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  18. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  19. A Survey of Titan Balloon Concepts and Technology Status

    Science.gov (United States)

    Hall, Jeffery L.

    2011-01-01

    This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.

  20. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  1. Linear ideal MHD stability calculations for ITER

    International Nuclear Information System (INIS)

    Hogan, J.T.

    1988-01-01

    A survey of MHD stability limits has been made to address issues arising from the MHD--poloidal field design task of the US ITER project. This is a summary report on the results obtained to date. The study evaluates the dependence of ballooning, Mercier and low-n ideal linear MHD stability on key system parameters to estimate overall MHD constraints for ITER. 17 refs., 27 figs

  2. Management of intra-aortic balloon pumps.

    Science.gov (United States)

    Webb, Christopher A-J; Weyker, Paul D; Flynn, Brigid C

    2015-06-01

    Intra-aortic balloon pumps (IABPs) continue to be the most widely used cardiac support devices with an annual estimate of 200 000 IABPs placed worldwide. IABPs enhance myocardial function by maximizing oxygen supply and minimizing oxygen demand. The use of IABPs is not without risk, with major vascular injury, ischemia, and infection being the most common complications, especially in high-risk patients. While recent studies have questioned the use of IABPs in patients with cardiogenic shock secondary to myocardial infarction, these studies have limitations making it difficult to formulate definitive conclusions. This review will focus on the mechanisms of counterpulsation, the management of IABPs and the evidence supporting this ventricular support therapy. © The Author(s) 2014.

  3. High Energy Antimatter Telescope (HEAT) Balloon Experiment

    Science.gov (United States)

    Beatty, J. J.

    1995-01-01

    This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.

  4. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  5. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  6. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  7. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  8. Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

    Science.gov (United States)

    Fan, Qiyong; Yeung, Anamaria R; Amdur, Robert; Helmig, Richard; Park, Justin; Li, Jonathan; Kahler, Darren; Liu, Chihray; Lu, Bo

    2017-06-01

    The efficacy of image-guided high-dose rate brachytherapy for cervical cancer is limited by the ineffective rectal sparing devices available commercially and the potential applicator movement. We developed a novel device using a balloon catheter and a belt immobilization system, serving for rectal dose reduction and applicator immobilization purposes, respectively. The balloon catheter is constructed by gluing a short inflatable tube to a long regular open-end catheter. Contrast agent (10) cm 3 is injected into the inflatable end, which is affixed to the tandem and ring applicator, to displace the posterior vaginal wall. The belt immobilization system consists of a specially designed bracket that can hold and fix itself to the applicator, a diaper-like Velcro fastener package used for connecting the patient's pelvis to the bracket, and a buckle that holds the fasteners to stabilize the whole system. The treatment data for 21 patients with cervical cancer using both balloon catheter and belt immobilization system were retrospectively analyzed. Computed tomography and magnetic resonance images, acquired about 30 minutes apart, were registered to evaluate the effectiveness of the immobilization system. In comparison with a virtual rectal blade, the balloon decreased the rectal point dose by 34% ± 4.2% (from 276 ± 57 to 182 ± 38 cGy), corresponding to an extra sparing distance of 7.9 ± 1.1 mm. The maximum sparing distance variation per patient is 1.4 ± 0.6 mm, indicating the high interfractional reproducibility for rectum sparing. With the immobilization system, the mean translational and rotational displacements of the applicator set are <3 mm and <1.5°, respectively, in all directions. The rectal balloon provides significant dose reduction to the rectum and it may potentially minimize patient discomfort. The immobilization system permits almost no movement of the applicator during treatment. This work has the potential to be promoted as a standardized solution

  9. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  10. Development of Venus Balloon Seismology Missions Through Earth Analog Experiments

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M. T.; Garcia, R. F.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-11-01

    The study of a planet’s seismic activity is central to the understanding of its internal structure. We discuss advances made through Earth analog testing for performing remote seismology on Venus using balloons floated in the mid-atmosphere.

  11. SMEX02 Balloon-borne Radiosonde Data, Iowa, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  12. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  13. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  14. Balloon valvuloplasty for severe mitral valve stenosis in pregnancy

    African Journals Online (AJOL)

    . Commerford, B. Levetan. Balloon Valvuloplasties for severe mitral stenosis were performed on 11 ... 140 patients each year with cardiac disease - an incidence of 0.5%. ... Department of Medicine, Groote Schuur Hospital and University of.

  15. 10 meter Sub-Orbital Large Balloon Reflector (LBR)

    Data.gov (United States)

    National Aeronautics and Space Administration — This is the lead NIAC Phase II proposal for “10 meter Sub-Orbital Large Balloon Reflector (LBR)” with Christopher K. Walker as PI. We propose to develop and...

  16. SMEX02 Balloon-borne Radiosonde Data, Iowa

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  17. Overview of the Scientific Balloon Activity in Sweden

    Science.gov (United States)

    Abrahamsson, Mattias; Kemi, Stig; Lockowandt, Christian; Andersson, Kent

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from ESC since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times are very beneficial for astronomical payloads, such as telescopes that need long observation times. In 2013 two such payloads were flown, the first called SUNRISE was a German/US solar telescope, and the other called PoGOLite with a Swedish gamma-ray telescope. In 14 days PoGOLite, which had permission to fly over Russia, made an almost complete circumpolar flight. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. University students from all over Europe are involved in flights from Esrange under a Swedish/German programme called BEXUS. Two stratospheric balloons are flown with student

  18. The Evaluation of Endoscopic Balloon Dilation Treatment for Benign

    Directory of Open Access Journals (Sweden)

    H. Ghofrani

    2008-04-01

    Full Text Available Background and ObjectiveBalloon dilatation of stricture is one of the new treatment methods for patients with Gastric Outlet Obstruction (GOO. Prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that could affect method advantage among patients with benign etiology for GOO. Methods Forty-five patients with symptoms of benign GOO were randomly selected. The mean age of patients was 43.7±18.1 years and 86.7% of them were men. Gastric outlet was delineated using double channel videoendoscopy. The severity of gastric pain was measured by VAS test immediately before and one month after balloon dilatation. Patients were followed after procedure weekly (for the first month and then monthly. Balloon dilatation was repeated for 27% patients during the follow up period.ResultsPatients were followed for 9.9±5.8 months. Furthermore, 71.1% were H. pylori positive. Positive response percent to endoscopic balloon dilatation was 80% and eight patients were took under surgical resection. Weight loss was seen frequently in the non-respondent group. The pain severity was significantly reduced in respondent subjects. No meaningful correlations were found between the response to balloon dilatation and positive H. pylori and cigarette smoking.ConclusionEndoscopic balloon dilatation is a safe and effective method for treating most of patients with benign gastric outlet obstruction and has favorable long-term outcome. Keywords: Endoscopy, Gastric Outlet Obstruction (GOO, Balloon Dilatation

  19. Numerical linear analysis of the effects of diamagnetic and shear flow on ballooning modes

    Science.gov (United States)

    Yanqing, HUANG; Tianyang, XIA; Bin, GUI

    2018-04-01

    The linear analysis of the influence of diamagnetic effect and toroidal rotation at the edge of tokamak plasmas with BOUT++ is discussed in this paper. This analysis is done by solving the dispersion relation, which is calculated through the numerical integration of the terms with different physics. This method is able to reveal the contributions of the different terms to the total growth rate. The diamagnetic effect stabilizes the ideal ballooning modes through inhibiting the contribution of curvature. The toroidal rotation effect is also able to suppress the curvature-driving term, and the stronger shearing rate leads to a stronger stabilization effect. In addition, through linear analysis using the energy form, the curvature-driving term provides the free energy absorbed by the line-bending term, diamagnetic term and convective term.

  20. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Bighi, G.

    1988-01-01

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  1. Retrograde prostatic urethroplasty with a balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    Twenty-five patients with prostatism and documented BPH who were candidates for transurethral resection of the prostate were dilated for 10 minutes with 25-mm urethroplasty balloons using a retrograde transurethral approach. The procedure was performed under local anesthesia using 2% viscous lidocaine on an outpatient basis. A mild discomfort was experienced by all patients with a moderate urgency sensation. Mild transient hematuria was present in all, which cleared in 4 to 6 hours. Dysuria usually lasted for 72 hours. Significant improvement has been seen in the relief of symptoms in patients without middle-lobe hypertrophy as documented by uroflow studies, voiding cystourethrograms, and retrograde urethrograms. In patients with middle-lobe hypertrophy, moderate improvement in uroflow studies was observed, which correlated well with symptomatic improvement. Rectal US and MR studies have shown no evidence of intraprostatic or periprostatic abnormalities. No complications have been encountered so far. The longest current follow-up is 20 months, with a mean of 10 months

  2. Mechanism of prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Maynar, M.; Hulbert, J.

    1988-01-01

    A series of 60 patients have undergone prostatic urethroplasty with balloon catheters at our institution. The follow-up of these patients has ranged from more than 3 years to not less than 6 months. The preliminary results have been excellent, with a success rate of 75% in patients with predominant lateral lobe hypertrophy. This success rate drops to 25% in patients with predominant middle lobe hypertrophy. In previous communications the authors have proposed that the mechanism of prostatic urethral relief of obstruction is due to stretching of the prostatic capsule, tissue compression, and possible subsequent atrophy, as suggested by findings of transrectal US, MR imaging, voiding and retrograde urethrography, and urinary flow studies. Recent clinical information that has led to further animal research has shown that in addition to the previously supposed mechanism of action, separation of the prostatic lobes occurs by splitting of the anterior and posterior commissures of the prostatic gland tissue. This separation of the prostatic lobes is therefore the goal of the procedure. As more experience is gained, the already high success rate can probably be improved

  3. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  4. Mobile platform security

    CERN Document Server

    Asokan, N; Dmitrienko, Alexandra

    2013-01-01

    Recently, mobile security has garnered considerable interest in both the research community and industry due to the popularity of smartphones. The current smartphone platforms are open systems that allow application development, also for malicious parties. To protect the mobile device, its user, and other mobile ecosystem stakeholders such as network operators, application execution is controlled by a platform security architecture. This book explores how such mobile platform security architectures work. We present a generic model for mobile platform security architectures: the model illustrat

  5. Nonpneumatic Antishock Garment Combined with Bakri Balloon as a Nonoperative “Uterine Sandwich” for Temporization of Massive Postpartum Hemorrhage from Disseminated Intravascular Coagulation

    Directory of Open Access Journals (Sweden)

    Andrea Jelks

    2015-01-01

    Full Text Available Disseminated intravascular coagulation (DIC is an uncommon but potentially catastrophic complication of postpartum hemorrhage. We describe two cases of massive postpartum hemorrhage complicated by DIC that were successfully temporized with combined use of the Bakri balloon and nonpneumatic antishock garment (NASG during massive transfusion. In the first case, a healthy, term gravida underwent emergent cesarean for fetal bradycardia during labor induction. 10 minutes after completion of surgery, brisk vaginal hemorrhage of nonclotting blood from fulminant DIC resulted in maternal shock. A Bakri balloon and NASG were placed during massive transfusion, resulting in rapid maternal stabilization. In the second case, a healthy, term gravida suffered an amniotic fluid embolism during labor requiring emergent cesarean delivery and complicated by cardiac arrest with successful resuscitation. Postoperative rapid uterine bleeding from DIC was treated with a Bakri balloon and NASG, stabilizing the patient during massive transfusion. Neither patient required further surgical procedures. NASG combined with Bakri balloon may serve as a valuable nonoperative treatment or temporization option in cases of massive postpartum hemorrhage complicated by coagulopathy such as these. Further study of the utility of NASG in high-resource settings is warranted.

  6. 25 Years of Atmospheric Science with the Balloon-borne Limb Sounder MIPAS-B

    Science.gov (United States)

    Oelhaf, H.; Friedl-Vallon, F.; Wetzel, G.; Ebersoldt, A.; Hoepfner, M.; Kleinert, A.; Maucher, G.; Maurer, K.; Nordmeyer, H.; Piesch, C.; Ruhnke, R.; Sartorius, C.; Sinnhuber, B. M.; Orphal, J.; Fischer, H.

    2017-12-01

    MIPAS-B (Michelson Interferometer for Passive Atmospheric Sounding - Balloon) is a balloon-borne limb-emission sounder for atmospheric research. The heart of the instrument is a Fourier spectrometer that covers the mid-infrared spectral range (4 to 14 µm) operating at a temperature of approximately 215 K. Essential for this application is the sophisticated line of sight stabilization system, which is based on an inertial navigation system and supplemented with a star camera reference system. The major scientific benefit of the instrument is the simultaneous detection of complete trace gas families in the stratosphere, without restrictions concerning time of the day and viewing directions. MIPAS-B is an in-house development that was started in the mid-eighties. It initially served as proof of concept for the proposed space borne MIPAS instrument that was later realized and operated on the ESA satellite ENVISAT between 2002 and 2012. But actually it soon became obvious that operation from stratospheric balloons offered a number of benefits to address dedicated scientific questions in an optimal way. MIPAS-B was operated in two versions during 24 flights at tropical, mid-latitudinal and arctic latitudes between 1989 and 2014 covering the `golden era' of ozone loss research and the full operational period of ENVISAT. This paper describes briefly specifications, design considerations, technological upgrades and the characterization of the instrument. Evolving skills with respect to its remote operation from ground and to data analysis in the course of the 25 years are outlined. Scientific applications in the field of atmospheric research, spectroscopy and satellite validation are highlighted with a focus on recent research concerning bromine nitrate and age of air.

  7. Cerebral ischemia associated with PercuSurge balloon occlusion balloon during carotid stenting: Incidence and possible mechanisms.

    Science.gov (United States)

    Chaer, Rabih A; Trocciola, Susan; DeRubertis, Brian; Lin, Stephanie C; Kent, K Craig; Faries, Peter L

    2006-05-01

    Interruption of antegrade cerebral perfusion results in transient neurologic intolerance in some patients undergoing carotid angioplasty and stenting (CAS). This study sought to evaluate factors that contributed to the development of cerebral ischemia during PercuSurge balloon occlusion and techniques used to allow successful completion of the CAS procedure. The PercuSurge occlusion balloon was used in 43 of 165 patients treated with CAS for high-grade stenosis (mean stenosis, 90%). All 43 patients were at increased risk for endarterectomy (7 restenosis, 3 irradiation, 3 contralateral occlusion, and 30 Goldman class II-III); 20% were symptomatic. Symptoms of cerebral hypoperfusion during temporary occlusion of the internal carotid artery occurred in 10 of 43 and included dysarthria (7/10), agitation (6/10), decreased level of consciousness (5/10), and focal hemispheric deficit (3/10). An incomplete circle of Willis or contralateral carotid artery occlusion, or both, was present in 8 of 10 patients. Symptoms resulting from PercuSurge balloon occlusion were managed by balloon deflation with or without evacuation of blood from the internal carotid artery using the Export catheter. All symptoms resolved completely without deficit after deflation of the occlusion balloon. The development of neurologic symptoms after initial PercuSurge balloon inflation and occluded internal carotid artery flow was associated with a decrease in the mean Glasgow Coma Scale (GCS) from 15 to 10 (range, 9 to 14); the GCS returned to normal after occlusion balloon deflation and remained normal during subsequent reinflation. The mean time to spontaneous recovery of full neurologic function was 8 minutes (range, 4 to 15 minutes). No thrombotic or embolic events were present on cerebral angiography or computed tomography scan. Balloon reinflation was performed after a mean reperfusion interval of 10 minutes after full neurologic recovery (range, 4 to 20 minutes). The mean subsequent procedure

  8. ITS Platform North Denmark

    DEFF Research Database (Denmark)

    Lahrmann, Harry; Agerholm, Niels; Juhl, Jens

    2012-01-01

    This paper presents the project entitled “ITS Platform North Denmark” which is used as a test platform for Intelligent Transportation System (ITS) solutions. The platform consists of a newly developed GNSS/GPRS On Board Unit (OBU) to be installed in 500 cars, a backend server and a specially...

  9. The BIRD payload platform

    Science.gov (United States)

    Walter, Ingo; Briess, Klaus; Baerwald, Wolfgang; Skrbek, Wolfgang; Schrandt, Fredrich

    2003-04-01

    For hot spot events as forest fires, volcanic activity or burning oil spills and coal seams a dedicate dspace instrumentation does not exist. With its successful launch end of October 2001 with the Indian Polar Satellite Launch Vehicle the German Aerospace Center starts closing this gap with the micro-satellite mission BIRD. As space segment serves a three-axis stabilized satellite of 92 kg including a contingent of over 30% for the scientific instruments. The main payload of the BIRD micro-satellite is the newly developed Hot Spot Recognition System. It's a dual-channel instrument for middle and thermal IR imagery based on cooled MCT line detectors. The miniaturization by integrated detector/cooler assemblies provides a highly efficient design. A complement for the hot spot detection is the wide-angle stereo-scanner WAOSS-B. It is a hardware re-use dedicated to vegetation and cloud assessment in the visible spectral range. Besides the main objective of hot spot detection the mission has to answer several technological questions of the operation of cooled detectors in space, special aspects of their adaptation to the satellite platform as well as their calibration.

  10. The ATIC Long Duration Balloon Project

    Science.gov (United States)

    Guzik, T.

    Long Duration Balloon (LDB) scientific experiments, launched to circumnavigate the south pole over Antarctica, have particular advantages compared to Shuttle or other Low Earth Orbit (LEO) missions in terms of cost, weight, scientific "duty factor" and work force development. The Advanced Thin Ionization Calorimeter (ATIC) cosmic ray astrophysics experiment is a good example of a university-based project that takes full advantage of current LDB capability and could effectively use future expansion in launch weight and flight duration. The ATIC experiment is currently being shipped to Antarctica in preparation for its first LDB science flight that will investigate the charge composition and energy spectra of primary cosmic rays over the energy range from about 101 0 to 10 1 4 eV. The instrument is built around a fully active, Bismuth Germanate (BGO) ionization calorimeter to measure the energy deposited by the cascades formed by particles interacting in a thick carbon target. A highly segmented silicon matrix, located above the target, provides good incident charge resolution plus rejection of the "backscattered" particles from the interaction. Trajectory reconstruction is based on the cascade profile in the BGO calorimeter, plus information from the three scintillator hodoscope layers in the target section above it. The hodoscope planes also provide the primary event trigger to initiate the detector readout, another measure of the incident particle charge and an indicator of the interaction point in the carbon material. The scientific payload weighs ~1,540 kg and consumes ~300 Watts of power supplied by a ~580 Watt solar array system. A full evaluation of the experiment was performed during a test flight occurring between 28 December 2000 and 13 January 2001 where ATIC was carried3 to an altitude of ~37 km above Antarctica by a ~850,000 m helium filled balloon for one circumnavigation of the continent. All systems behaved well, the detectors performed as expected

  11. Advances in the Remote Monitoring of Balloon Flights

    Science.gov (United States)

    Breeding, S.

    At the National Scientific Balloon Facility (NSBF), we must staff the Long Duration Balloon (LDB) control center 24 hours a day during LDB flights. This requires three daily shifts of two operators (balloon control and tdrss scheduling). In addition to this we also have one engineer on-call as LDB Lead to resolve technical issues and one manager on-call for flight management. These on-call periods are typically 48 to 72 hours in length. In the past the on-call staff had to travel to the LDB control center in order to monitor the status of a flight in any detail. This becomes problematic as flight durations push out beyond 20 to 30 day lengths, as these staff members are not available for business travel during these periods. This paper describes recent advances which allow for the remote monitoring of scientific balloon flight ground station computer displays. This allows balloon flight managers and lead engineers to check flight status and performance from any location with a network or telephone connection. This capability frees key personnel from the NSBF base during flights. It also allows other interested parties to check on the flight status at their convenience.

  12. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  13. A Distributed, Real-Time Data Monitoring System as Ground Support Equipment for Balloon-Borne Astronomy Experiments

    Science.gov (United States)

    Chen, C. M. H.; Baumgartner, W. H.; Cook, W. R.; Davis, A. J.; Harrison, F. A.

    2010-12-01

    We present a real-time data-monitoring software suite that we developed for the High Energy Focusing Telescope (HEFT). HEFT was one of the first projects to develop focusing mirrors and detectors for hard X-ray astronomy. We deployed these new technologies on the scientific ballooning platform. During a balloon flight, this so-called ‘ground support equipment’ (GSE) allows us to monitor the physical condition of the payload, and to inspect preliminary science data in real time, through displays of tables of frequently updated quantities and their averages, time-series plots, histograms, spectra, and images. Unique from previous implementations of GSE s for other experiments, our system is a server-client network that utilises TCP/IP unicast and UDP multicast to enable multiple, concurrent and independent display clients. Most of the code is in Java, and thus platform-independent. We verified that the software suite works on Linux, Mac OS/X and Windows XP, deployed it in two flight campaigns for use during on-site calibration, pre-launch practice drills, and an observation flight of 24 hours. This system, and individual ideas of its implementation, can be adapted for use in future experiments requiring sophisticated real-time monitoring and data display.

  14. Cross-Platform Technologies

    Directory of Open Access Journals (Sweden)

    Maria Cristina ENACHE

    2017-04-01

    Full Text Available Cross-platform - a concept becoming increasingly used in recent years especially in the development of mobile apps, but this consistently over time and in the development of conventional desktop applications. The notion of cross-platform software (multi-platform or platform-independent refers to a software application that can run on more than one operating system or computing architecture. Thus, a cross-platform application can operate independent of software or hardware platform on which it is execute. As a generic definition presents a wide range of meanings for purposes of this paper we individualize this definition as follows: we will reduce the horizon of meaning and we use functionally following definition: a cross-platform application is a software application that can run on more than one operating system (desktop or mobile identical or in a similar way.

  15. Recent Progress in MHD Stability Calculations of Compact Stellarators

    International Nuclear Information System (INIS)

    Fu, G.Y.; Ku, L.P.; Redi, M.H.; Kessel, C.; Monticello, D.A.; Reiman, A.; Cooper, W.A.; Nuehrenberg, C.; Sanchez, R.; Ware, A.; Hirshman, S.P.; Spong, D.A.

    2000-01-01

    A key issue for compact stellarators is the stability of beta-limiting MHD modes, such as external kink modes driven by bootstrap current and pressure gradient. We report here recent progress in MHD stability studies for low-aspect-ratio Quasi-Axisymmetric Stellarators (QAS) and Quasi-Omnigeneous Stellarators (QOS). We find that the N = 0 periodicity-preserving vertical mode is significantly more stable in stellarators than in tokamaks because of the externally generated rotational transform. It is shown that both low-n external kink modes and high-n ballooning modes can be stabilized at high beta by appropriate 3D shaping without a conducting wall. The stabilization mechanism for external kink modes in QAS appears to be an enhancement of local magnetic shear due to 3D shaping. The stabilization of ballooning mode in QOS is related to a shortening of the normal curvature connection length

  16. Observational Study of Large-Scale [CII] Emission by Balloon-Borne Infrared Telescope (BIRT)

    Science.gov (United States)

    Shibai, H.

    1992-11-01

    A far-infrared emission line of C+ ion ([CII] 158 μm) was detected in an extensive region (30o BIRT) was used. It has been developed for far-infrared astronomy by a joint project (BIRT project) between the Institute of Space and Astronautical Science (ISAS) and Kyoto University in Japan. BIRT has a 50 cm reflector telescope mounted on an alt-azimuthal pointing system actuated by a control-moment gyro (CMG) torquer in the azimuth. The pointing and tracking are accomplished by a unique offset guide system which utilizes a star tracker and a star field camera mounted on a two-axis offset gimbals. The motion of the gimbals is controlled by an on-board CPU which computes and corrects the rotation rate of the offset direction caused by the celestial diurnal motion as well as the horizontal motion of the balloon gondola. BIRT has been flown 6 times at Alice Springs, Australia in 1985 and 1986, and 2 times at Palestine, Texas in 1988. The pointing and tracking accuracies were better than I arcmin and the peak-to-peak attitude stability was sma.]ler than 30 arcsec in those fiights. The last two flights, at which liquid helium cooled Fabry-Perot spectrometer was mounted on the Nasmyth focus, were quite successful for observing far-infrared spectral lines of [CII] (158 μm) and [OI] (63 μm) over wide areas of several galactic nebulae and Milky Way. These observations have demonstrated that balloon-borne observation is a quite useful method for far-infrared spectroscopy. Chapter I is an introduction for the far-infrared spectroscopic study. Chapter 2 describes the balloon-borne infrared telescope, BIRT. Chapter 3 shows a major result of our balloon observation., that is, a detection of the diffuse photodissociation regions. Chapter 2 and 3 refer to [Shibai et al. 1990] and [Shibai et al. 1991], respectively. Appendix A is a review of the far-infrared line observations. In appendix B and C, I provide compilations of far-infrared line parameters and observational work

  17. Review of the British scientific sounding rocket and balloon programmes

    International Nuclear Information System (INIS)

    Delury, J.T.

    1978-01-01

    This review describes the UK scientific sounding rocket programmes which have utilised Skylarks for 21 years, Petrels for 10 years and Fulmars for 2 years. The SRC's ongoing programme is now based on the Petrel and Fulmar rockets, and approved proposals by 5 UK scientific groups covering 1978 and 1979 are outlined. The British scientific balloon programme, which serves 14 scientific groups within UK universities, involves a planned 10 flights per annum using balloons of 3 M cu ft to 31 M cu ft capacity and payloads up to 2 tons in weight. The review outlines the balloon programme of flights planned mainly from Palestine in Texas and Alice Springs/Mildura in Australia. (author)

  18. Popping balloons: formation of a crack network in rubber membranes

    Science.gov (United States)

    Moulinet, Sebastien; Adda-Bedia, Mokhtar; Equipe Morphogenèse et phénomènes multi-échelle Team

    2015-03-01

    Everyone can make the observation: a rubber balloon inflated until it spontaneously pop breaks into a large number of shreds. In contrast, a balloon pierced with a needle at an early stage of its inflation breaks into two large pieces. Using model latex balloons, we have experimentally investigated the transition between these two breaking regimes. We have showed that, above a threshold stress in the latex membrane, a single crack become unstable and separates into two new cracks. Then, a cascade of tip-splitting generates a network of cracks that eventually form a large number of fragments. We have observed that the instability of the crack occurs when it reaches a limit velocity that could the speed of sound. By studying the energy balance during the explosion, we can determine the intrinsic fracture energy of rubber, a measurement difficult to achieve with usual tensile testing.

  19. JUBA (Joint UAS-Balloon Activities) Final Campaign Report.

    Energy Technology Data Exchange (ETDEWEB)

    Dexheimer, Darielle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Apple, Monty [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Callow, Diane Schafer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Longbottom, Casey Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Novick, David K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilson, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, JUBA was a collaborative exercise between SNL Orgs. 6533 & 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and UAS on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the ARM AMF3 site at Oliktok Point, Alaska. The Restricted Airspace occupies a 2 nautical mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 – 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability.

  20. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik

    2015-01-01

    , and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess...... if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected...... patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction...

  1. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  2. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  3. Particle Astrophysics in NASA's Long Duration Balloon Program

    Energy Technology Data Exchange (ETDEWEB)

    Gorham, Peter W.

    2013-10-15

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons.

  4. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    Science.gov (United States)

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. AIAA Educator Academy: The Space Weather Balloon Module

    Science.gov (United States)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  6. Cloud Water Content Sensor for Sounding Balloons and Small UAVs

    Science.gov (United States)

    Bognar, John A.

    2009-01-01

    A lightweight, battery-powered sensor was developed for measuring cloud water content, which is the amount of liquid or solid water present in a cloud, generally expressed as grams of water per cubic meter. This sensor has near-zero power consumption and can be flown on standard sounding balloons and small, unmanned aerial vehicles (UAVs). The amount of solid or liquid water is important to the study of atmospheric processes and behavior. Previous sensing techniques relied on strongly heating the incoming air, which requires a major energy input that cannot be achieved on sounding balloons or small UAVs.

  7. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S.; Giacomelli, G.; Manzoor, S.; Medinaceli, E.; Patrizii, L.; Togo, V.

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  8. Polymer blends for LDB applications. [Long Duration Ballooning

    Science.gov (United States)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  9. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  10. The German scientific balloon and sounding rocket programme

    International Nuclear Information System (INIS)

    Dahl, A.F.

    1980-01-01

    This report contains information on sounding rocket projects in the scientific field of astronomy, aeronomy, magnetosphere, and material science under microgravity. The scientific balloon projects are performed with emphasis on astronomical research. By means of tables it is attempted to give a survey, as complete as possible, of the projects the time since the last symposium in Ajaccio, Corsica, and of preparations and plans for the future until 1983. The scientific balloon and sounding rocket projects form a small successful part of the German space research programme. (Auth.)

  11. The effects of sloshing energetic particles on ballooning modes in tokamaks

    International Nuclear Information System (INIS)

    Stotler, D.P.; Berk, H.L.

    1986-10-01

    Distributions that give rise to energetic trapped particle pressures peaked in the ''good curvature'' region of a tokamak (sloshing distributions) are examined in an attempt to find stable regimes for both the magnetohydrodynamic (MHD) and precessional modes. It is the precessional drift destabilization of ballooning modes that inhibits bridging the unstable gap to second stability by the use of deeply-trapped energetic particles unless the hot particles have an extremely large energy (∼0.35 MeV for a tokamak like PDX). Unfortunately, our calculations indicate that the sloshing particles do not have a significant stabilizing effect. An analytic treatment shows that complete stability can be found only if the sign of the energetic particle magnetic drift-frequency can be reversed from its value in vacuum bad curvature without hot species diamagnetism. This is difficult to do in a tokamak because of the destabilizing contribution of the geodesic curvature to the drift frequency. Furthermore, for each of the two sloshing distributions employed (one contains only trapped particles; the other includes trapped and passing particles), a new ''continuum instability'' (where asymptotically along the field line the mode is a propagating plane wave) is found to be driven by geodesic curvature. These results indicate that energetic sloshing particles are not able to bridge the unstable gap to second stability

  12. BioEnterics Intragastric Balloon (BIB) versus Spatz Adjustable Balloon System (ABS): Our experience in the elderly.

    Science.gov (United States)

    Russo, Teresa; Aprea, Giovanni; Formisano, Cesare; Ruggiero, Simona; Quarto, Gennaro; Serra, Raffaele; Massa, Guido; Sivero, Luigi

    2017-02-01

    The BioEnterics Intragastric Balloon (BIB) and the Spatz Adjustable Balloon System (ABS) are in fact recommended for weight reduction as a bridge to bariatric surgery. We retrospected studied patients with body mass index (BMI) and age ranges of 37-46 and 70-80 years, respectively, who had undergone BIB from January 2010 to July 2012 and prospected studied patients who had undergone Spatz balloon from July 2012 to August 2014. The aim of this study is to compare BIB and Spatz in terms of weight loss, complications, and maintenance of weight after removal. For both procedures, the median weight loss was 20 ± 3 kg, median BMI at the end of the therapy was 32 ± 2, and no severe complication occurred. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Product Platform Modeling

    DEFF Research Database (Denmark)

    Pedersen, Rasmus

    on the notion that reuse and encapsulation of platform elements are fundamental characteristics of a product platform. Reuse covers the desire to reuse and share certain assets across a family of products and/or across generations of products. Product design solutions and principles are often regarded...... as important assets in a product platform, yet activities, working patterns, processes and knowledge can also be reused in a platform approach. Encapsulation is seen as a process in which the different elements of a platform are grouped into well defined and self-contained units which are decoupled from each...... support decision makers during a product platform project. The reaction from stakeholders in the case companies indicates that the decision base is improved by means of visual models. Another finding is that the sometimes rather theoretical and intangible phenomena can be instantiated in models...

  14. Continuous Platform Development

    DEFF Research Database (Denmark)

    Nielsen, Ole Fiil

    evolution does not make the platforms irrelevant. This research is based on case studies and applications in the two Danish companies, LEGO and Grundfos, where several platform development projects have been followed. LEGO is exceptional for their long experience with platform development and maintenance......, while Grundfos is relatively new within this area. This study puts emphasis on platform projects and defines such projects as something very different from product development projects and more similar to industrial research projects, due to the fact that they are continuous activities with relatively...... low risks and investments but also with relatively fuzzy results. When looking for new platform projects, it is important to make sure that the company and market is ready for the introduction of platforms, and to make sure that people from marketing and sales, product development, and downstream...

  15. Inexpensive Demonstration of Diffraction-Limited Telescope from NASA Stratospheric Balloons

    Science.gov (United States)

    Young, Elliot

    NASA s Balloon Program often flies payloads to altitudes of 120,000 ft or higher, above 99.5% of the atmosphere. At those altitudes, the imaging degradation due to atmospheric- induced wavefront errors is virtually zero. In 2009, the SUNRISE balloon mission quantified the wavefront errors with a Shack-Hartmann array and found no evidence of wavefront errors. This means that a large telescope on a balloon should be able to achieve diffraction-limited performance, provided it can be stabilized at a level that is finer than the diffraction limit. At visible wavelengths, the diffraction limit of a 1 or 2 m telescope is 0.1 arcsec or 0.05 arcsec, respectively. NASA recently demonstrated WASP (the Wallops Arc-Second Pointing system) on a balloon flight in October 2011, a coarse pointing system that kept a dummy telescope (24 ft long, 1500 lbs) stabilized at the 0.25 arcsec level. We propose to use an orthogonal transfer CCD (OTCCD) from MIT Lincoln Laboratory to improve the pointing to 0.05 arcsec, an order of magnitude better than the coarse pointing alone and sufficient to provide long integrations at the diffraction limit of a 2-m telescope. Imaging in visible wavelengths is an important new capability. Ground-based adaptive optics (AO) systems on 8-m and 10-m class telescope cannot effectively correct for atmospheric turbulence at wavelengths shorter than 1 μm; the atmospheric wavefront errors are larger at these wavelengths than in the infrared J-H-K bands. At present, only the Hubble Space Telescope can achieve 0.05 arcsec resolution images in visible wavelengths, a capability that is dramatically oversubscribed. With a camera based on an MIT/LL OTCCD, a 2-m balloon-borne telescope could match the spatial resolution of HST. Under this project (and in conjunction with a SWRI Internal Research proposal), we will perform ground tests of a motion-compensation camera based on an MIT/LL Orthogonal Transfer CCD (OTCCD). This device can shift charge in four directions

  16. ADMS Evaluation Platform

    Energy Technology Data Exchange (ETDEWEB)

    2018-01-23

    Deploying an ADMS or looking to optimize its value? NREL offers a low-cost, low-risk evaluation platform for assessing ADMS performance. The National Renewable Energy Laboratory (NREL) has developed a vendor-neutral advanced distribution management system (ADMS) evaluation platform and is expanding its capabilities. The platform uses actual grid-scale hardware, large-scale distribution system models, and advanced visualization to simulate realworld conditions for the most accurate ADMS evaluation and experimentation.

  17. Currency trading platform

    OpenAIRE

    DEL BARRIO ALBELDA, ALBERTO

    2015-01-01

    This project aims to build a web platform for intra day currency investors. Using the platform a trader is able to place orders, in real time, in the btc-e.com exchange, view the state of his wallet, look over the past orders and transactions, check the balance of his account, etc. The project fetches, stores, analyzes and transforms the information provided by the API of the exchange. The platform enhances and adds functionality to basic operations provided by the exchan...

  18. BOU: Development of a low-cost tethered balloon sensing system for monitoring the lower atmosphere

    Science.gov (United States)

    Picos, Rodrigo; Lopez-Grifol, Alvaro; Martinez-Villagrassa, Daniel; Simó, Gemma; Wenger, Burkhard; Dünnermann, Jens; Jiménez, Maria Antonia; Cuxart, Joan

    2016-04-01

    The study of the atmospheric boundary layer, the lowest part of the atmosphere, and the processes that occur therein often requires the observation of vertical profiles of the main meteorological variables, i.e. air temperature and humidity, wind vector and barometric pressure. In particular, when the interest is focused on the air-surface interactions, a high vertical resolution over the first 500 m is required for the observations to describe the physical processes that occur immediately above the surface. Typically, these needs are covered with the use of captive balloons, which are helium-filled balloons tethered to a winch on the ground and a sensor package suspended a short distance below the balloon. Since the commercial version of such instrumental platforms are scarce and expensive, a new low-cost device has been developed in the last years: BOU (tethered Balloon sonde OWL-UIB). In this paper, we focus on the sensor package and data acquisition system part, that is able to fulfill the low-cost requirements. The system uses a low-cost Arduino Mega board as the processor, and stores all the data in a SD card, though an RF connection is also possible but more unreliable. The system has been configured to sample temperature, humidity, air pressure, wind speed, having also a magnetometer and an accelerometer. Sampling time was 1 second, though it was possible to set it faster. It is worth mentioning that the system is easily reconfigurable, and more sensors can be added. The system is powered by a Polymer battery of 1800mA , allowing the system to run continously for more than 6 hours. The temperature is acquired using three different sensors (a HYT 271 calibrated sensor with an accuracy of ±0.2 °C, plus the internal temperature sensors of the wind and pressure sensors, with accuracies around ±0.5 °C). The humidity is also sensed using the calibrated HYT 271 sensor, which features an accuracy of ±1.8%. Air pressure is sensed using a BMP080 sensor, which

  19. Omnidirectional holonomic platforms

    International Nuclear Information System (INIS)

    Pin, F.G.; Killough, S.M.

    1994-01-01

    This paper presents the concepts for a new family of wheeled platforms which feature full omnidirectionality with simultaneous and independently controlled rotational and translational motion capabilities. The authors first present the orthogonal-wheels concept and the two major wheel assemblies on which these platforms are based. They then describe how a combination of these assemblies with appropriate control can be used to generate an omnidirectional capability for mobile robot platforms. The design and control of two prototype platforms are then presented and their respective characteristics with respect to rotational and translational motion control are discussed

  20. Platform decommissioning costs

    International Nuclear Information System (INIS)

    Rodger, David

    1998-01-01

    There are over 6500 platforms worldwide contributing to the offshore oil and gas production industry. In the North Sea there are around 500 platforms in place. There are many factors to be considered in planning for platform decommissioning and the evaluation of options for removal and disposal. The environmental impact, technical feasibility, safety and cost factors all have to be considered. This presentation considers what information is available about the overall decommissioning costs for the North Sea and the costs of different removal and disposal options for individual platforms. 2 figs., 1 tab

  1. Resistive ballooning modes in an axisymmetric toroidal plasma with long mean-free path

    International Nuclear Information System (INIS)

    Connor, J.W.; Chen, L.

    1984-08-01

    Tokamak devices normally operate at such high temperatures that the resistive fluid description is inappropriate. In particular, the collision frequency may be low enough for trapped particles to exist. However, on account of the high conductivity of such plasmas, one can identify two separate scale lengths when discussing resistive ballooning modes. By describing plasma motion on one of these, the connection length, in terms of kinetic theory the dynamics of trapped particles can be incorporated. On the resistive scale length, this leads to a description in terms of modified fluid equations in which trapped particle effects appear. The resulting equations are analyzed and the presence of trapped particles is found to modify the stability properties qualitatively

  2. Bone cements for percutaneous vertebroplasty and balloon kyphoplasty: Current status and future developments

    Directory of Open Access Journals (Sweden)

    Zhiwei He

    2015-01-01

    Full Text Available Osteoporotic vertebral compression fractures (OVCFs have gradually evolved into a serious health care problem globally. In order to reduce the morbidity of OVCF patients and improve their life quality, two minimally invasive surgery procedures, vertebroplasty (VP and balloon kyphoplasty (BKP, have been developed. Both VP and BKP require the injection of bone cement into the vertebrae of patients to stabilize fractured vertebra. As such, bone cement as the filling material plays an essential role in the effectiveness of these treatments. In this review article, we summarize the bone cements that are currently available in the market and those still under development. Two major categories of bone cements, nondegradable acrylic bone cements (ABCs and degradable calcium phosphate cements (CPCs, are introduced in detail. We also provide our perspectives on the future development of bone cements for VP and BKP.

  3. Effects of Hemibridge with Ball and Balloon Exercise on Forced Expiratory Volume and Pain in Patients with Chronic Low Back Pain: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Jorida Fernandes

    2017-08-01

    Full Text Available Background and objectives: Suboptimal breathing patterns and impairments of posture and trunk stability are often associated with musculoskeletal complaints such as low back pain. Respiration is also affected by poor neuromuscular control of core muscles. Immediate effects of hemibridge with ball and balloon exercise has been studied on chronic pain in athlete population. Objective: To evaluate the effects of hemibridge with ball and balloon exercise on pain, forced expiratory volume and functional abilities in patients with chronic low back pain using Visual Analogue Scale (VAS, Forced Expiratory Volume (FEV and Modified Oswestry Disability Questionnaire (MODQ. Methods: The present experimental study was conducted among 30 participants between the age of 21 to 55 years with chronic non-specific LBP. The participants were given a hemibridge with ball and balloon exercise. Pre-interventional and 3rd day Post-interventional outcome measurements were taken using VAS, FEV1 and FEV6 and MODQ. Results: The difference between pre-and post of VAS was statistically highly significant (p=0.0001. The p value of FEV6 and MODQ by paired t test was statistically significant with p value of 0.02 and 0.0007 respectively. Conclusion: The study concludes that there is an immediate effect of hemibridge with ball and balloon exercise on pain, FEV6 and functional ability in patients with chronic LBP.

  4. 28. Critical pulmonary valve stenosis: Medical management beyond balloon dilation

    Directory of Open Access Journals (Sweden)

    Muhammad Arif Khan

    2015-10-01

    Conclusion: Phentolamine and/or Captopril have a therapeutic role in neonates with critical PVS who remain oxygen dependent after balloon dilation. Both medicationslead to vasodilatation of pulmonary and systemic vascularity. They facilitate inflowto the right ventricle. Right to left shunt across a PFO or/ ASD minimizesand saturation improves leading to a significantreduction in length of hospitalization.

  5. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  6. Percutaneous transvenous angioplasty of inferior vena cava by balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung Suk; Kim, Jae Kyu; Park, Jin Gyun; Kang, Heung Keun; Chung, Hyon De; Kim, Shin Kon; Chung, Sang Young [Chonnam National University College of Medicine, Kwangju (Korea, Republic of)

    1989-10-15

    3 patients with membranous (2 patients) and segmental (1 patient) obstruction of IVC were successfully treated by percutaneous transvenous angioplasty using balloon catheter. Improvements of clinical and radiological findings could be obtained after procedures. Relatively good patency was obtained in all cases without complications. This procedure can be applied safely to membranous or segmental obstructions of IVC and elsewhere in the venous systems.

  7. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  8. Balloon atrial septostomy under echocardiographic guide: case series

    Directory of Open Access Journals (Sweden)

    SM Meraji

    2012-12-01

    Full Text Available Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. However, not all centers performing early arterial switch repairs have abandoned atrial septostomy, even in patients who respond favorably to prostaglandin infusion.Case presentation: In total, eight 1- to 15-day old term neonates admitted in Shahid Rajaee Heart Center in Tehran, Iran from October 2009 to February 2011, with congenital heart diseases were scheduled for balloon atrial septostomy. In six cases the procedure was done exclusively under echocardiographic guidance and in two cases with the help of fluoroscopy. Success was defined as the creation of an atrial septal defect with a diameter equal to or more than 5 mm and ample mobility of its margins.Results: Male sex was predominant (87% and the mean age of the neonates was six days. The diagnosis in all cases was simple transposition of great arteries. The procedure was successful in all patients with any cardiovascular complication.Conclusion: Balloon atrial septostomy is an emergent procedure that can be done safely and effectively under echocardiographic guidance. According to the feasibility of this technique it could be performed fast, safe and effective at bedside, avoiding patient transportation to hemodynamic laboratory or referral center.

  9. Balloon valvuloplasty for severe mitral valve stenosis in pregnancy ...

    African Journals Online (AJOL)

    Balloon valvuloplasties for severe mitral stenosis were performed on 11 pregnant patients with excellent resutts and no complications. The mitral valve area was increased from a mean of 0.9 cnr to 2.1 cnr. There was no clinically significant mitral regurgitation. The pregnancies proceeded normally to delivery at or near tenn, ...

  10. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    Science.gov (United States)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  11. Achilles tests finally nail PWR fuel clad ballooning fears

    International Nuclear Information System (INIS)

    Dore, P.; McMinn, K.

    1992-01-01

    A conclusive series of experiments carried out by AEA Reactor Services at its Achilles rig in the UK has finally allayed fears that fuel clad ballooning is a major safety problem for Sizewell B, Britain's first Pressurized Water Reactor. The experiments are described in this article. (author)

  12. Balloon dilatation of isolated severe tricuspid valve stenosis

    Directory of Open Access Journals (Sweden)

    Rajeev Bhardwaj

    2015-12-01

    Full Text Available Tricuspid valve stenosis is mostly rheumatic in origin. It almost always occurs in association with mitral valve disease. There are only few case reports of isolated tricuspid valve stenosis. We report a case of isolated tricuspid valve stenosis, which was treated with balloon dilatation.

  13. Balloon dilatation of isolated severe tricuspid valve stenosis

    OpenAIRE

    Bhardwaj, Rajeev; Sharma, Rajesh

    2015-01-01

    Tricuspid valve stenosis is mostly rheumatic in origin. It almost always occurs in association with mitral valve disease. There are only few case reports of isolated tricuspid valve stenosis. We report a case of isolated tricuspid valve stenosis, which was treated with balloon dilatation.

  14. [Expansion dilatation balloons for cervical ripening in obstetric practice].

    Science.gov (United States)

    Ducarme, G; Grange, J; Vital, M

    2016-02-01

    During recent decades, mechanical devices have been substituted by pharmacological methods. Their place in the therapeutic arsenal remains important with a renewed obstetrical interest for these devices. Due to a lack of data they are still not recommended as first-line. This review thus attempted to examine the use of expansion dilatation balloons (Foley catheter and double-balloons) to analyze their effectiveness in case of native uterus and previous cesarean section. Twenty-seven clinical trials had compared balloons catheter and prostaglandins in patients without a history of uterine scar. The risk of cesarean section did not differ. Mechanical methods seemed to be more effective in achieving delivery within 24hours, with fewer episodes of excessive uterine contractions, but they necessitated more oxytocin during labor. Ten clinical trials analyzed dilatation balloons in patients with previous cesarean section. More than 70% women had favorable cervical ripening (Bishop score>6), and vaginal delivery was reported between 35 and 70% of patients. The risk of uterine rupture was low between 0.64 and 0.72%, with neither increased risk of severe neonatal and maternal morbidity nor increased risk of infectious morbidity. Mechanical methods are effective and safe for third trimester cervical ripening, mainly in women with previous cesarean section. Potential advantages may include wide availability and reduction of some of the side effects. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  16. Platform development supportedby gaming

    DEFF Research Database (Denmark)

    Mikkola, Juliana Hsuan; Hansen, Poul H. Kyvsgård

    2007-01-01

    , possibly increasing the strategic risks for the firm. This paper reports preliminary findings on platform management process at LEGO, a Danish toy company.  Specifically, we report the process of applying games combined with simulations and workshops in the platform development. We also propose a framework...

  17. Groundwater Assessment Platform

    OpenAIRE

    Podgorski, Joel; Berg, Michael

    2018-01-01

    The Groundwater Assessment Platform is a free, interactive online GIS platform for the mapping, sharing and statistical modeling of groundwater quality data. The modeling allows users to take advantage of publicly available global datasets of various environmental parameters to produce prediction maps of their contaminant of interest.

  18. National Report on the NASA Sounding Rocket and Balloon Programs

    Science.gov (United States)

    Eberspeaker, Philip; Fairbrother, Debora

    2013-01-01

    The U. S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 30 to 40 missions per year in support of the NASA scientific community and other users. The NASA Sounding Rockets Program supports the science community by integrating their experiments into the sounding rocket payloads, and providing both the rocket vehicle and launch operations services. Activities since 2011 have included two flights from Andoya Rocket Range, more than eight flights from White Sands Missile Range, approximately sixteen flights from Wallops Flight Facility, two flights from Poker Flat Research Range, and four flights from Kwajalein Atoll. Other activities included the final developmental flight of the Terrier-Improved Malemute launch vehicle, a test flight of the Talos-Terrier-Oriole launch vehicle, and a host of smaller activities to improve program support capabilities. Several operational missions have utilized the new Terrier-Malemute vehicle. The NASA Sounding Rockets Program is currently engaged in the development of a new sustainer motor known as the Peregrine. The Peregrine development effort will involve one static firing and three flight tests with a target completion data of August 2014. The NASA Balloon Program supported numerous scientific and developmental missions since its last report. The program conducted flights from the U.S., Sweden, Australia, and Antarctica utilizing standard and experimental vehicles. Of particular note are the successful test flights of the Wallops Arc Second Pointer (WASP), the successful demonstration of a medium-size Super Pressure Balloon (SPB), and most recently, three simultaneous missions aloft over Antarctica. NASA continues its successful incremental design qualification program and will support a science mission aboard WASP in late 2013 and a science mission aboard the SPB in early 2015. NASA has also embarked on an intra-agency collaboration to launch a rocket from a balloon to

  19. Generalised ballooning theory of two-dimensional tokamak modes

    Science.gov (United States)

    Abdoul, P. A.; Dickinson, D.; Roach, C. M.; Wilson, H. R.

    2018-02-01

    In this work, using solutions from a local gyrokinetic flux-tube code combined with higher order ballooning theory, a new analytical approach is developed to reconstruct the global linear mode structure with associated global mode frequency. In addition to the isolated mode (IM), which usually peaks on the outboard mid-plane, the higher order ballooning theory has also captured other types of less unstable global modes: (a) the weakly asymmetric ballooning theory (WABT) predicts a mixed mode (MM) that undergoes a small poloidal shift away from the outboard mid-plane, (b) a relatively more stable general mode (GM) balloons on the top (or bottom) of the tokamak plasma. In this paper, an analytic approach is developed to combine these disconnected analytical limits into a single generalised ballooning theory. This is used to investigate how an IM behaves under the effect of sheared toroidal flow. For small values of flow an IM initially converts into a MM where the results of WABT are recaptured, and eventually, as the flow increases, the mode asymptotically becomes a GM on the top (or bottom) of the plasma. This may be an ingredient in models for understanding why in some experimental scenarios, instead of large edge localised modes (ELMs), small ELMs are observed. Finally, our theory can have other important consequences, especially for calculations involving Reynolds stress driven intrinsic rotation through the radial asymmetry in the global mode structures. Understanding the intrinsic rotation is significant because external torque in a plasma the size of ITER is expected to be relatively low.

  20. Cryo-balloon catheter position planning using AFiT

    Science.gov (United States)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  1. Product Platform Replacements

    DEFF Research Database (Denmark)

    Sköld, Martin; Karlsson, Christer

    2012-01-01

    . To shed light on this unexplored and growing managerial concern, the purpose of this explorative study is to identify operational challenges to management when product platforms are replaced. Design/methodology/approach – The study uses a longitudinal field-study approach. Two companies, Gamma and Omega......Purpose – It is argued in this article that too little is known about product platforms and how to deal with them from a manager's point of view. Specifically, little information exists regarding when old established platforms are replaced by new generations in R&D and production environments...... distinguishing between platform replacement “height” and “width”. Seven groups of managerial measures for dealing with the issues are recommended. Originality/value – The study aims to contribute to the existing literature by taking a managers' perspective of product platform development. Its specific...

  2. Embolization of carotid-cavernous fistula using a silicone balloon and a tracker-catheter system

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Cho, Kil Ho; Park, Bok Hwan

    1992-01-01

    With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in case of small fistula, pseudo aneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitation, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients (silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing

  3. The VISPA Internet Platform for Students

    Science.gov (United States)

    Asseldonk, D. v.; Erdmann, M.; Fischer, R.; Glaser, C.; Müller, G.; Quast, T.; Rieger, M.; Urban, M.

    2016-04-01

    The VISPA internet platform enables users to remotely run Python scripts and view resulting plots or inspect their output data. With a standard web browser as the only user requirement on the client-side, the system becomes suitable for blended learning approaches for university physics students. VISPA was used in two consecutive years each by approx. 100 third year physics students at the RWTH Aachen University for their homework assignments. For example, in one exercise students gained a deeper understanding of Einsteins mass-energy relation by analyzing experimental data of electron-positron pairs revealing J / Ψ and Z particles. Because the students were free to choose their working hours, only few users accessed the platform simultaneously. The positive feedback from students and the stability of the platform lead to further development of the concept. This year, students accessed the platform in parallel while they analyzed the data recorded by demonstrated experiments live in the lecture hall. The platform is based on experience in the development of professional analysis tools. It combines core technologies from previous projects: an object-oriented C++ library, a modular data-driven analysis flow, and visual analysis steering. We present the platform and discuss its benefits in the context of teaching based on surveys that are conducted each semester.

  4. A Balloon-Borne Telescope System for Planetary Atmosphere and Plasma Studies

    Science.gov (United States)

    Taguchi, M.; Yoshida, K.; Sakamoto, Y.; Kanazawa, T.; Shoji, Y.; Sawakami, T.; Takahashi, Y.; Hoshino, N.; Sato, T.; Sakanoi, T.

    2007-12-01

    A telescope floating in the polar stratosphere can continuously monitor planets for more than 24 hours. Thin, clear and stable air of the stratosphere makes it possible to observe planets in a condition free from cloud with fine seeing and high atmospheric transmittance. Moreover, a balloon-borne telescope system is less expensive compared with a huge terrestrial telescope or a direct planetary probe mission. Targets of a balloon-borne telescope system will extend over various atmospheric and plasma phenomena on almost all the planets, i.e., a sodium tail of Mercury, lightning, airglow and aurora in the atmospheres of Venus, Jupiter and Saturn, escaping atmospheres of the Earth-type planets, satellite-induced luminous events in the Jovian atmosphere, etc. The first target is global dynamics of the Venusian atmosphere by detecting cloud motion in UV and NIR imagery. A decoupling mechanism and a pair of control moment gyros (CMGs) are mounted at the top of the gondola. The decoupling mechanism isolates the gondola from a balloon and also transfers an excess angular momentum of the CMGs to the balloon. The attitude of the gondola is stabilized at a constant sun azimuthal angle so that a solar cell panel faces to the sun. A 300 mm F30 Schmidt-Cassegrain telescope is installed at the bottom of the gondola. DC/DC converters, a PC, a high voltage power supply for a piezo-electrically moving mirror and digital video recorders are contained in a sealed cell. The azimuthal angle is detected by a sun-sensor. A PC processes sensor output to control DC motors used in the decoupling mechanism and CMGs with an accuracy in azimuthal attitude of about 0.5 deg. The two-axis gimbal mount of the telescope is controlled by the same PC, guiding an object within a field-of-view of a guide telescope. Residual tracking error is detected by a position sensitive photomultiplier tube and corrected by the two-axis moving mirror installed in the optical system. The optical path is divided into

  5. The vacuum platform

    Science.gov (United States)

    McNab, A.

    2017-10-01

    This paper describes GridPP’s Vacuum Platform for managing virtual machines (VMs), which has been used to run production workloads for WLCG and other HEP experiments. The platform provides a uniform interface between VMs and the sites they run at, whether the site is organised as an Infrastructure-as-a-Service cloud system such as OpenStack, or an Infrastructure-as-a-Client system such as Vac. The paper describes our experience in using this platform, in developing and operating VM lifecycle managers Vac and Vcycle, and in interacting with VMs provided by LHCb, ATLAS, ALICE, CMS, and the GridPP DIRAC service to run production workloads.

  6. Ladder attachment platform

    Science.gov (United States)

    Swygert,; Richard, W [Springfield, SC

    2012-08-28

    A ladder attachment platform is provided that includes a base for attachment to a ladder that has first and second side rails and a plurality of rungs that extend between in a lateral direction. Also included is a user platform for having a user stand thereon that is carried by the base. The user platform may be positioned with respect to the ladder so that it is not located between a first plane that extends through the first side rail and is perpendicular to the lateral direction and a second plane that extends through the second side rail and is perpendicular to the lateral direction.

  7. Minimal invasive stabilization of osteoporotic vertebral compression fractures. Methods and preinterventional diagnostics

    International Nuclear Information System (INIS)

    Grohs, J.G.; Krepler, P.

    2004-01-01

    Minimal invasive stabilizations represent a new alternative for the treatment of osteoporotic compression fractures. Vertebroplasty and balloon kyphoplasty are two methods to enhance the strength of osteoporotic vertebral bodies by the means of cement application. Vertebroplasty is the older and technically easier method. The balloon kyphoplasty is the newer and more expensive method which does not only improve pain but also restores the sagittal profile of the spine. By balloon kyphoplasty the height of 101 fractured vertebral bodies could be increased up to 90% and the wedge decreased from 12 to 7 degrees. Pain was reduced from 7,2 to 2,5 points. The Oswestry disability index decreased from 60 to 26 points. This effects persisted over a period of two years. Cement leakage occurred in only 2% of vertebral bodies. Fractures of adjacent vertebral bodies were found in 11%. Good preinterventional diagnostics and intraoperative imaging are necessary to make the balloon kyphoplasty a successful application. (orig.) [de

  8. The data processor of the EUSO-Balloon experiment

    International Nuclear Information System (INIS)

    Scotti, V; Osteria, G

    2014-01-01

    The JEM-EUSO instrument is a wide-angle refractive telescope in near-ultraviolet wavelength region being proposed for attachment to the Japanese Experiment Module (JEM) onboard International Space Station (ISS). The main scientific goal of the mission is the study of Extreme Energy Cosmic Rays (EECR) above 5 × 10 19 eV. The instrument consists of high transmittance optical Fresnel lenses with a diameter of 2.5 m, a focal surface covered by ∼ 5000 Multi Anode Photo Multiplier Tubes of 64 pixels, front-end readout, trigger and system electronics. The EUSO-Balloon experiment is a pathfinder mission in which a telescope of smaller dimension than the one designed for the ISS will be mounted onboard a stratospheric balloon. The main objective of this pathfinder mission, planned for 2014, is to perform a full scale end-to-end test of all the key technologies and instrumentation of JEM-EUSO detectors and to prove the global detection chain. Furthermore, EUSO-Balloon will measure the atmospheric and terrestrial UV background components, in different observational modes, fundamental for the development of the simulations. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-Balloon also has the potential to detect Extensive Air Showers from above, paving the way for any future large scale, space-based EECR observatory. In this paper we will present the Data Processor (DP) of EUSO-Balloon, which is the component of the Electronics System which performs the data management and the instrument control. More in detail, the DP controls the front-end electronics, performs the 2nd level trigger filtering, tags events with arrival time and payload position through a GPS system, manages the Mass Memory for data storage, measures live and dead time of the telescope, provides signals for time synchronization of the event, performs housekeeping monitor, and handles the interface to the telemetry system. The DP has to operate at high

  9. Product Platform Performance

    DEFF Research Database (Denmark)

    Munk, Lone

    , and the subject has gained increased attention in industry and academia the past decade. Literature on platform-based product development is often based on single case studies and it is sparsely verified if expected effects are achieved. This makes it difficult to put forward realistic expectations for companies.......e. if the expected results are achieved), and • reasons for possible deviations between these, comparing them to existing platform assessment criteria. The research results are based on 8 comprehensive case studies of product platforms in LEGO Company in the period of 2004-2009 (involving participant observation...... effects. The model empirically verifies findings in literature and received moderate support from industry in the validation study. The research findings document that product platforms achieve significant internal effects in terms of • reduced development time (often around 25 %), • reduced number...

  10. Cellular Sentinels Toxicity Platform

    Science.gov (United States)

    2017-02-01

    Screening hits in red for ENZO cardiotoxicity library tested in the phenotypic and physiology platforms at the indicated incubation times...assay timeline .................................................................................... 34 Figure 27. Automated algorithm detection of...40 Figure 33. Automated algorithm detection of multiplexed dyes for

  11. USA Hire Testing Platform

    Data.gov (United States)

    Office of Personnel Management — The USA Hire Testing Platform delivers tests used in hiring for positions in the Federal Government. To safeguard the integrity of the hiring processes and ensure...

  12. The Creative Platform

    DEFF Research Database (Denmark)

    Byrge, Christian; Hansen, Søren

    whether you consider thirdgrade teaching, human-resource development, or radical new thinking in product development in a company. The Creative Platform was developed at Aalborg University through a series of research-and-development activities in collaboration with educational institutions and private......This book is about introducing more creativity into general educational courses and cross-disciplinary activities. It is directed toward teachers at all levels in the educational system, but the Creative Platform is a general model, and thus the creative process will fundamentally be the same...... companies. It is a project in which the goal is to make a hands-on approach to a knowledge perspective on enhancing creativity. The underlying ambition of the Creative Platform is to make it easier to promote creativity. At www.uka.aau.dk/The+Creative+Platform, you can find extra materials and instructions...

  13. Intelligent passively stabilized quadrotor

    Science.gov (United States)

    Sayfeddine, D.; Bulgakov, A. G.; Kruglova, T. N.

    2017-10-01

    Quadrotor stability is one of the most topical researches worldwide. It is due to the simplicity, availability and cost of such platform. This miniature aerial vehicle is highly manoeuvrable, straight forward to use and to maintain. It can be deployed to perform wide variety of tasks. On the other hand, the quadrotor suffers from non-stability, which makes it unreliable, especially when flying on low speed, high altitude and in windy circumstances. This paper discusses the improvement of the quadrotor by adding a stabilizing mechanism working as a passive breaking system in sharp and spontaneous turns. The mechanism is described and simulated as a standalone module. The end result represents the determination of the stiffness coefficient of the stabilizing actuator using fuzzy logic controller.

  14. An analysis of the deployment of a pumpkin balloon at Mars

    Science.gov (United States)

    Rand, J. L.; Phillips, M. L.

    2004-01-01

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, where the radius used to determine the stress is determined by the volume of the balloon, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. A suitable superpressure balloon has been designed using this technology which will carry 2 kg in the atmosphere of Mars. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a 10 kg system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred into the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon which alters the pressure distribution and shape. As a result, stresses are seen to increase beyond the design values which will require the balloon to be redesigned to accommodate this type of dynamic deployment.

  15. Feasibility of a low-cost sounding rockoon platform

    Science.gov (United States)

    Okninski, Adam; Raurell, Daniel Sors; Mitre, Alberto Rodriguez

    2016-10-01

    This paper presents the results of analyses and simulations for the design of a small sounding platform, dedicated to conducting scientific atmospheric research and capable of reaching the von Kármán line by means of a rocket launched from it. While recent private initiatives have opted for the air launch concept to send small payloads to Low Earth Orbit, several historical projects considered the use of balloons as the first stage of orbital and suborbital platforms, known as rockoons. Both of these approaches enable the minimization of drag losses. This paper addresses the issue of utilizing stratospheric balloons as launch platforms to conduct sub-orbital rocket flights. Research and simulations have been conducted to demonstrate these capabilities and feasibility. A small sounding solid propulsion rocket using commercially-off-the-shelf hardware is proposed. Its configuration and design are analyzed with special attention given to the propulsion system and its possible mission-orientated optimization. The cost effectiveness of this approach is discussed. Performance calculation outcomes are shown. Additionally, sensitivity study results for different design parameters are given. Minimum mass rocket configurations for various payload requirements are presented. The ultimate aim is to enhance low-cost experimentation maintaining high mobility of the system and simplicity of operations. An easier and more affordable access to a space-like environment can be achieved with this system, thus allowing for widespread outreach of space science and technology knowledge. This project is based on earlier experience of the authors in LEEM Association of the Technical University of Madrid and the Polish Small Sounding Rocket Program developed at the Institute of Aviation and Warsaw University of Technology in Poland.

  16. Calibration platforms for gravimeters

    Science.gov (United States)

    Vanruymbeke, M.

    Several methods investigated in order to calibrate gravimeters by the inertial acceleration produced by a vertical motion are described. The VRR 8601 calibrating platform is especially designed to calibrate La Coste and Romberg gravimeters. For heavier gravimeters such as tidal La Coste or superconducting instruments, two other principles are possible to lift up sinusoidally the platform: a mercury crapaudine or the rotation on an inclined plane.

  17. Autonomous Landing on Moving Platforms

    KAUST Repository

    Mendoza Chavez, Gilberto

    2016-08-01

    This thesis investigates autonomous landing of a micro air vehicle (MAV) on a nonstationary ground platform. Unmanned aerial vehicles (UAVs) and micro air vehicles (MAVs) are becoming every day more ubiquitous. Nonetheless, many applications still require specialized human pilots or supervisors. Current research is focusing on augmenting the scope of tasks that these vehicles are able to accomplish autonomously. Precise autonomous landing on moving platforms is essential for self-deployment and recovery of MAVs, but it remains a challenging task for both autonomous and piloted vehicles. Model Predictive Control (MPC) is a widely used and effective scheme to control constrained systems. One of its variants, output-feedback tube-based MPC, ensures robust stability for systems with bounded disturbances under system state reconstruction. This thesis proposes a MAV control strategy based on this variant of MPC to perform rapid and precise autonomous landing on moving targets whose nominal (uncommitted) trajectory and velocity are slowly varying. The proposed approach is demonstrated on an experimental setup.

  18. National Community Solar Platform

    Energy Technology Data Exchange (ETDEWEB)

    Rupert, Bart [Clean Energy Collective, Louisville, CO (United States)

    2016-06-30

    This project was created to provide a National Community Solar Platform (NCSP) portal known as Community Solar Hub, that is available to any entity or individual who wants to develop community solar. This has been done by providing a comprehensive portal to make CEC’s solutions, and other proven community solar solutions, externally available for everyone to access – making the process easy through proven platforms to protect subscribers, developers and utilities. The successful completion of this project provides these tools via a web platform and integration APIs, a wide spectrum of community solar projects included in the platform, multiple groups of customers (utilities, EPCs, and advocates) using the platform to develop community solar, and open access to anyone interested in community solar. CEC’s Incubator project includes web-based informational resources, integrated systems for project information and billing systems, and engagement with customers and users by community solar experts. The combined effort externalizes much of Clean Energy Collective’s industry-leading expertise, allowing third parties to develop community solar without duplicating expensive start-up efforts. The availability of this platform creates community solar projects that are cheaper to build and cheaper to participate in, furthering the goals of DOE’s SunShot Initiative. Final SF 425 Final SF 428 Final DOE F 2050.11 Final Report Narrative

  19. Dosimetry of beta emitting radionuclides for use in balloon angioplasty

    International Nuclear Information System (INIS)

    Fox, R.A.

    1997-01-01

    The dose at varying distances from the surface of an infinite cylinder containing 90 Y, 32 P and 188 Re respectively is calculated using published scaled point dose kernels for these three radionuclides. It is shown that all are suitable radionuclides for use in the irradiation of arteries subsequent to balloon angioplasty. All three may be used as a radioactive liquid in the angioplasty balloon, thereby simplifying the procedure and enabling a uniform radiation dose to be given to the arterial wall. It is however shown that there is a rapid reduction in dose with distance from the arterial wall which demands careful specification of the prescribed radiation dose. A similar rapid reduction with distance is also found with a central radioactive wire or with a radioactive stent containing the same radionuclides. (author)

  20. Star camera aspect system suitable for use in balloon experiments

    International Nuclear Information System (INIS)

    Hunter, S.D.; Baker, R.G.

    1985-01-01

    A balloon-borne experiment containing a star camera aspect system was designed, built, and flown. This system was designed to provide offset corrections to the magnetometer and inclinometer readings used to control an azimuth and elevation pointed experiment. The camera is controlled by a microprocessor, including commendable exposure and noise rejection threshold, as well as formatting the data for telemetry to the ground. As a background program, the microprocessor runs the aspect program to analyze a fraction of the pictures taken so that aspect information and offset corrections are available to the experiment in near real time. The analysis consists of pattern recognition of the star field with a star catalog in ROM memory and a least squares calculation. The performance of this system in ground based tests is described. It is part of the NASA/GSFC High Energy Gamma-Ray Balloon Instrument (2)

  1. Accelerated partial breast irradiation utilizing balloon brachytherapy techniques

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Dickler, Adam

    2009-01-01

    To overcome the barriers to BCT, methods of PBI in the setting of breast conservation have been explored. The method of PBI with the longest published follow-up is multi-catheter interstitial brachytherapy. Balloon-based brachytherapy with the MammoSite brachytherapy applicator was designed to simplify the brachytherapy procedure for PBI, enhance the reproducibility of the dosimetry, and improve patient comfort. The rates of local recurrence following PBI with the MammoSite applicator have been low, but there are few published reports and follow-up has been relatively short. The cosmetic outcomes and toxicity of MammoSite PBI are comparable to those seen after multicatheter-based PBI. Additional methods of balloon brachytherapy, including Xoft and SenoRx Contura have been developed. Finally, long-term follow-up after PBI is important for the welfare of individual patients and in order to establish the efficacy, late toxicity and cosmetic outcomes of this technique.

  2. Transjugular balloon mitral valvotomy in a patient with severe kyphoscoliosis

    Directory of Open Access Journals (Sweden)

    George Joseph

    2016-09-01

    Full Text Available Balloon mitral valvotomy (BMV performed by the conventional transfemoral approach can be difficult or even impossible in the presence of structural impediments such as severe kyphoscoliosis, gross cardiac anatomic distortion and inferior vena caval anomalies. A 25-year-old woman with severe thoracolumbar kyphoscoliosis due to poliomyelitis presented with symptomatic rheumatic mitral valve stenosis. After the failure of transfemoral BMV, the procedure was attempted from the right jugular access, using a modified septal puncture technique. The left atrium was entered from the jugular access and the mitral valve was crossed and dilated successfully using over the wire balloon technique. Transjugular BMV is an effective alternative in patients with kyphoscoliotic spine that preclude transfemoral approach. The detailed technique used for the procedure, its advantages as well as the other percutaneous treatment options are also discussed.

  3. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    metabolic profile was significantly different. Clamp occlusion was associated with a significantly higher lactate burden and vasopressor requirement in...balloon occlusion. This was associated with a significant metabolic burden as measured by serum lactate; however, with suitable resuscitation, this...interleukin 10, reduces nuclear factor kB DNA binding, and improves short term survival in lethal endotoxemia . Crit Care Med 2004;32:801. [36] Manning JE

  4. Percutaneous balloon valvuloplasty of a stenosed mitral bioprosthesis.

    Science.gov (United States)

    Fernandez, J J; DeSando, C J; Leff, R A; Ord, M; Sabbagh, A H

    1990-01-01

    A 62-year-old woman with disabling mitral prosthetic stenosis underwent percutaneous balloon valvuloplasty. The transvalvular gradient preoperatively was 22 mm Hg and was reduced to 6 mm Hg after the valvuloplasty. the valve area was increased from an initial value of 0.77 cm2 to 1.53 cm2. No complications occurred related to the Further studies are necessary to ascertain the indications and long-term results of percutaneous valvuloplasty on bioprosthesis in the mitral position.

  5. Prime time for drug eluting balloons in SFA interventions?

    Science.gov (United States)

    Brodmann, M

    2014-08-01

    Peripheral arterial disease most commonly affects the femoropopliteal segment. Despite enormous improvements in device and treatment technology the long-term patency rate and clinical benefit of endovascular treatment in the respective vascular bed is not satisfying. Drug coated balloon technology as a treatment option in femoropopliteal disease has shown encouraging results in first-in-man trials, which have now been proven in large randomized controlled trials.

  6. A Sensitivity Analysis of fMRI Balloon Model

    KAUST Repository

    Zayane, Chadia

    2015-04-22

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  7. Balloon Cell Urethral Melanoma: Differential Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    M. McComiskey

    2015-01-01

    Full Text Available Introduction. Primary malignant melanoma of the urethra is a rare tumour (0.2% of all melanomas that most commonly affects the meatus and distal urethra and is three times more common in women than men. Case. A 76-year-old lady presented with vaginal pain and discharge. On examination, a 4 cm mass was noted in the vagina and biopsy confirmed melanoma of a balloon type. Preoperative CT showed no distant metastases and an MRI scan of the pelvis demonstrated no associated lymphadenopathy. She underwent anterior exenterative surgery and vaginectomy also. Histology confirmed a urethral nodular malignant melanoma. Discussion. First-line treatment of melanoma is often surgical. Adjuvant treatment including chemotherapy, radiotherapy, or immunotherapy has also been reported. Even with aggressive management, malignant melanoma of the urogenital tract generally has a poor prognosis. Recurrence rates are high and the mean period between diagnosis and recurrence is 12.5 months. A 5-year survival rate of less than 20% has been reported in balloon cell melanomas along with nearly 20% developing local recurrence. Conclusion. To the best of our knowledge, this case is the first report of balloon cell melanoma arising in the urethra. The presentation and surgical management has been described and a literature review provided.

  8. The Rocket Balloon (Rocketball): Applications to Science, Technology, and Education

    Science.gov (United States)

    Esper, Jaime

    2009-01-01

    Originally envisioned to study upper atmospheric phenomena, the Rocket Balloon system (or Rocketball for short) has utility in a range of applications, including sprite detection and in-situ measurements, near-space measurements and calibration correlation with orbital assets, hurricane observation and characterization, technology testing and validation, ground observation, and education. A salient feature includes the need to reach space and near-space within a critical time-frame and in adverse local meteorological conditions. It can also provide for the execution of technology validation and operational demonstrations at a fraction of the cost of a space flight. In particular, planetary entry probe proof-of-concepts can be examined. A typical Rocketball operational scenario consists of a sounding rocket launch and subsequent deployment of a balloon above a desired location. An obvious advantage of this combination is the additional mission 'hang-time' rendered by the balloon once the sounding rocket flight is completed. The system leverages current and emergent technologies at the NASA Goddard Space Flight Center and other organizations.

  9. Giant High-Flow Type Pulmonary Arteriovenous Malformation: Coil Embolization with Flow Control by Balloon Occlusion and an Anchored Detachable Coil

    Energy Technology Data Exchange (ETDEWEB)

    Kanematsu, Masayuki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Watanabe, Haruo [Gifu University Hospital, Gifu (Japan); Moriyama, Noriyuki [National Cancer Center Hospital, Tokyo (Japan)

    2012-01-15

    Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.

  10. Giant High-Flow Type Pulmonary Arteriovenous Malformation: Coil Embolization with Flow Control by Balloon Occlusion and an Anchored Detachable Coil

    International Nuclear Information System (INIS)

    Kanematsu, Masayuki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Watanabe, Haruo; Moriyama, Noriyuki

    2012-01-01

    Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.

  11. Effect of routine rapid insertion of Bakri balloon tamponade on reducing hemorrhage from placenta previa during and after cesarean section.

    Science.gov (United States)

    Soyama, Hiroaki; Miyamoto, Morikazu; Sasa, Hidenori; Ishibashi, Hiroki; Yoshida, Masashi; Nakatsuka, Masaya; Takano, Masashi; Furuya, Kenichi

    2017-09-01

    To evaluate the effectiveness of routine rapid insertion of a Bakri balloon during cesarean section for placenta previa based on a retrospective control study. Women with singleton pregnancies who underwent cesarean section for placenta previa at our institution between 2003 and 2016 were enrolled. Between 2015 and 2016, women who routinely underwent balloon tamponade during cesarean section were defined as the balloon group. Between 2003 and 2014, women who underwent no hemostatic procedures except balloon tamponade were defined as the non-balloon group. The clinical outcomes of the two groups were retrospectively analyzed. Of the 266 women with placenta previa, 50 were in the balloon group and 216 were in the non-balloon group. The bleeding amounts were significantly smaller in the balloon group than in the non-balloon group: intraoperative bleeding (991 vs. 1250 g, p placenta previa.

  12. Experimental investigation of undesired stable equilibria in pumpkin shape super-pressure balloon designs

    Science.gov (United States)

    Schur, W. W.

    2004-01-01

    Excess in skin material of a pneumatic envelope beyond what is required for minimum enclosure of a gas bubble is a necessary but by no means sufficient condition for the existence of multiple equilibrium configurations for that pneumatic envelope. The very design of structurally efficient super-pressure balloons of the pumpkin shape type requires such excess. Undesired stable equilibria in pumpkin shape balloons have been observed on experimental pumpkin shape balloons. These configurations contain regions with stress levels far higher than those predicted for the cyclically symmetric design configuration under maximum pressurization. Successful designs of pumpkin shape super-pressure balloons do not allow such undesired stable equilibria under full pressurization. This work documents efforts made so far and describes efforts still underway by the National Aeronautics and Space Administration's Balloon Program Office to arrive on guidance on the design of pumpkin shape super-pressure balloons that guarantee full and proper deployment.

  13. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation.

    Science.gov (United States)

    Ghosh, Justin; Sepahpour, Ali; Chan, Kim H; Singarayar, Suresh; McGuire, Mark A

    2013-05-01

    Persistent phrenic nerve palsy is the most frequent complication of cryoballoon ablation for atrial fibrillation and can be disabling. To describe a technique-immediate balloon deflation (IBD)-for the prevention of persistent phrenic nerve palsy, provide data for its use, and describe in vitro simulations performed to investigate the effect of IBD on the atrium and pulmonary vein. Cryoballoon procedures for atrial fibrillation were analyzed retrospectively (n = 130). IBD was performed in patients developing phrenic nerve dysfunction (n = 22). In vitro simulations were performed by using phantoms. No adverse events occurred, and all patients recovered normal phrenic nerve function before leaving the procedure room. No patient developed persistent phrenic nerve palsy. The mean cryoablation time to onset of phrenic nerve dysfunction was 144 ± 64 seconds. Transient phrenic nerve dysfunction was seen more frequently with the 23-mm balloon than with the 28-mm balloon (11 of 39 cases vs 11 of 81 cases; P = .036). Balloon rewarming was faster following IBD. The time to return to 0 and 20° C was shorter in the IBD group (6.7 vs 8.9 seconds; P = .007 and 16.7 vs 37.6 seconds; P<.0001). In vitro simulations confirmed that IBD caused more rapid tissue warming (time to 0°C, 14.0 ± 3.4 seconds vs 46.0 ± 8.1; P = .0001) and is unlikely to damage the atrium or pulmonary vein. IBD results in more rapid tissue rewarming, causes no adverse events, and appears to prevent persistent phrenic nerve palsy. Simulations suggest that IBD is unlikely to damage the atrium or pulmonary vein. Copyright © 2013 Heart Rhythm Society. All rights reserved.

  14. Transactional Network Platform: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Lutes, Robert G.; Ngo, Hung; Underhill, Ronald M.

    2013-10-31

    In FY13, Pacific Northwest National Laboratory (PNNL) with funding from the Department of Energy’s (DOE’s) Building Technologies Office (BTO) designed, prototyped and tested a transactional network platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). Initially, in FY13, the concept demonstrated transactions between packaged rooftop air conditioners and heat pump units (RTUs) and the electric grid using applications or "agents" that reside on the platform, on the equipment, on a local building controller or in the Cloud. The transactional network project is a multi-lab effort with Oakridge National Laboratory (ORNL) and Lawrence Berkeley National Laboratory (LBNL) also contributing to the effort. PNNL coordinated the project and also was responsible for the development of the transactional network (TN) platform and three different applications associated with RTUs. This document describes two applications or "agents" in details, and also summarizes the platform. The TN platform details are described in another companion document.

  15. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Sinus Balloon Dilation as Treatment for Acute Sphenoid Sinusitis with Impaired Vision for a Child

    Directory of Open Access Journals (Sweden)

    Yin Zhao

    2016-01-01

    Full Text Available This paper is about sinus balloon dilatation in treatment of acute left sphenoid sinusitis with left impaired vision in a child. Balloon catheter dilatation (BCD of the sinus ostia is a new technique. It has been shown to be a minimally invasive technique to manage chronic sinusitis. However, this method is rarely used in the treatment of acute sinusitis. So far, we know of no reported cases of sinus balloon dilatation in treatment of this case, especially for children.

  17. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  18. Linear and nonlinear studies of resistive-ballooning modes in a tokamak edge plasma with scrape-off layer

    International Nuclear Information System (INIS)

    Lau, Y.T.; Novakovskii, S.V.; Drake, J.F.

    1996-01-01

    We will present 2D linear and 3D nonlinear studies of resistive-ballooning modes in tokamak edge plasmas which include a closed flux region, as well as a limiter scrape-off layer (SOL) region. These studies therefore go beyond most earlier work, where the stability of the edge in the closed flux region and in the SOL have been considered separately. A 2D linear code, 2D-BALLOON, examines the stability of these curvature driven modes and provides the complete 2D eigenfunction spanning the closed flux surface region as well the open field line region. The sheath boundary condition in the SOL introduces an important new parameter λ = (m e /m i ) 1/2 v ei qR/v Te . This parameter plays a significant role in determining the stability of these modes in both the closed flux and SOL regions because of the radial coupling across the last closed flux surface (LCFS). For small λ the spectrum of unstable modes is broad and extends into the low toroidal mode number exclamation point regime where the spatial structure is flute-like. The amplitude for these modes is larger in the SOL compared to the closed flux region. However when A is increased, the low mode numbers are strongly stabilized and the high mode numbers which are strongly ballooning are the dominant modes. In this regime the radial modes straddle the LCFS. In both these cases, the variation in the plasma density is necessary for the radial localization. In the three-dimensional nonlinear simulations, we have solved a set of fluid equations in a toroidal geometry with both the closed flux region and the SOL. The introduction of the SOL to the twisted tube for the closed flux region, has been a major addition to our 3D code. We find that the turbulent transport in the SOL drops significantly as A is increased, which is consistent with our expectations from the 2D linear code results

  19. Design and evaluation of a continuum robot with extendable balloons

    Directory of Open Access Journals (Sweden)

    E. Y. Yarbasi

    2018-02-01

    Full Text Available This article presents the design and preliminary evaluation of a novel continuum robot actuated by two extendable balloons. Extendable balloons are utilized as the actuation mechanism of the robot, and they are attached to the tip from their slack sections. These balloons can extend very much in length without having a significant change in diameter. Employing two balloons in an axially extendable, radially rigid flexible shaft, radial strain becomes constricted, allowing high elongation. As inflated, the balloons apply a force on the wall of the tip, pushing it forward. This force enables the robot to move forward. The air is supplied to the balloons by an air compressor and its flow rate to each balloon can be independently controlled. Changing the air volumes differently in each balloon, when they are radially constricted, orients the robot, allowing navigation. Elongation and force generation capabilities and pressure data are measured for different balloons during inflation and deflation. Afterward, the robot is subjected to open field and maze-like environment navigation tests. The contribution of this study is the introduction of a novel actuation mechanism for soft robots to have extreme elongation (2000 % in order to be navigated in substantially long and narrow environments.

  20. Use of Cutting Balloon in the Treatment of Urethral Stricture: A Novel Technique

    International Nuclear Information System (INIS)

    Yildirim, Erkan; Cicek, Tufan; Istanbulluoglu, Okan; Ozturk, Bulent

    2009-01-01

    The peripheral cutting balloon has been used to treat various nonvascular strictures as well as vascular stenosis. In this article, we describe for the first time the use of the cutting balloon in the treatment of patients with urethral stricture. Four patients with bulbar urethral stricture were included in the study. All strictures were successfully dilated with the cutting balloon, and patients were free of symptoms at 6-month follow-up. Cutting-balloon dilatation is a safe, easy-to-perform, and effective treatment for patients with tight urethral strictures.

  1. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    Energy Technology Data Exchange (ETDEWEB)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young [Univerisyt of Ulsan College of Medicine, Seoul (Korea, Republic of); Kang, Wee Chang [Daejeon University, Daejeon (Korea, Republic of)

    2005-09-15

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms ({rho} < 0.001). A significant difference was also found between group III and IV for both phantoms ({rho} < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body.

  2. Hybrid cutting balloon dilatation for treatment of cor triatriatum sinister in a cat.

    Science.gov (United States)

    Stern, Joshua A; Tou, Sandra P; Barker, Piers C A; Hill, Kevin D; Lodge, Andrew J; Mathews, Kyle G; Keene, Bruce W

    2013-09-01

    A hybrid surgical approach and balloon dilatation were performed successfully in a cat with cor triatriatum sinister and clinical signs of congestive heart failure. Left lateral thoracotomy was used to access the heart and cutting balloon followed by standard balloon dilatation were utilized to dilate the perforation in the anomalous left atrial membrane. Clinical signs resolved completely after dilation of the anomalous left atrial membrane. Based upon the outcome of this case, balloon dilatation appears to be a viable treatment option for cats affected with cor triatriatum sinister. Published by Elsevier B.V.

  3. Wave power absorption by a submerged balloon fixed to the sea bed

    DEFF Research Database (Denmark)

    Kurniawan, Adi; Greaves, Deborah

    2016-01-01

    The possibility of absorbing wave energy using a submerged balloon fixed to the sea bed is investigated. The balloon is in the form of a fabric encased within an array of meridional tendons which terminate at a point at the top of the balloon and at some radius at the bottom. The expansion...... and contraction of the balloon in waves pump air via a turbine into and out of a chamber of constant volume. A more refined model than that used by Kurniawan and Greaves [Proc. 2nd Offshore Energy and Storage Symposium , 2015] predicts a similarly broad-banded response, but the maximum absorption is less than...

  4. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    International Nuclear Information System (INIS)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young; Kang, Wee Chang

    2005-01-01

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (ρ < 0.001). A significant difference was also found between group III and IV for both phantoms (ρ < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body

  5. Usefulness of cutting balloon angioplasty for the treatment of congenital heart defects.

    Science.gov (United States)

    Kusa, Jacek; Mazurak, Magdalena; Skierska, Agnieszka; Szydlowski, Leslaw; Czesniewicz, Pawel; Manka, Lukasz

    2017-11-13

    Patients with complex congenital heart defects may have different hemodynamic problems which require a variety of interventional procedures including angioplasty which involves using high-pressure balloons. After failure of conventional balloon angioplasty cutting balloon angioplasty is the next treatment option available. The purpose of this study was to evaluate the safety and efficacy of cutting balloon angioplasty in children with different types of congenital heart defects. Cutting balloon angioplasty was performed in 28 children with different congenital heart defects. The indication for cutting balloon angioplasty was: pulmonary artery stenosis in 17 patients, creating or dilatation of interatrial communication in 10 patients, and stenosis of left subclavian artery in 1 patient. In the pulmonary arteries group there was a significant decrease in systolic blood pressure (SBP) in the proximal part of the artery from the average 74.33 ± 20.4 mm Hg to 55 ± 16.7 mm Hg (p cutting balloon angioplasty was performed after an unsuccessful classic Rashkind procedure. After cutting balloon angioplasty there was a significant widening of the interatrial communication. Cutting balloon angioplasty is a feasible and effective treatment option indifferent congenital heart defects.

  6. Identification of platform levels

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik

    2005-01-01

    These years many companies are changing their product development from single to multi product development, meaning that not only one product is developed but product families. There are many reasons for this change, but among the most important ones are reduction of time to market, total cost...... product development in one step and therefore the objective of this paper is to identify levels of platform based product development. The structure of this paper is as follows. First the applied terminology for platforms will be briefly explained and then characteristics between single and multi product...... development will be examined. Based on the identification of the above characteristics five platform levels are described. The research presented in this paper is a result of MSc, Ph.D projects at the Technical University of Denmark and consultancy projects within the organisation of Institute of Product...

  7. Reusable platform concepts

    International Nuclear Information System (INIS)

    Gudmestad, O.T.; Sparby, B.K.; Stead, B.L.

    1993-01-01

    There is an increasing need to reduce costs of offshore production facilities in order to make development of offshore fields profitable. For small fields with short production time there is in particular a need to investigate ways to reduce costs. The idea of platform reuse is for such fields particularly attractive. This paper will review reusable platform concepts and will discuss their range of application. Particular emphasis will be placed on technical limitations. Traditional concepts as jackups and floating production facilities will be discussed by major attention will be given to newly developed ideas for reuse of steel jackets and concrete structures. It will be shown how the operator for several fields can obtain considerable savings by applying such reusable platform concepts

  8. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2010-01-01

    The Azure Services Platform is a brand-new cloud-computing technology from Microsoft. It is composed of four core components-Windows Azure, .NET Services, SQL Services, and Live Services-each with a unique role in the functioning of your cloud service. It is the goal of this book to show you how to use these components, both separately and together, to build flawless cloud services. At its heart Windows Azure Platform is a down-to-earth, code-centric book. This book aims to show you precisely how the components are employed and to demonstrate the techniques and best practices you need to know

  9. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2011-01-01

    The Windows Azure Platform has rapidly established itself as one of the most sophisticated cloud computing platforms available. With Microsoft working to continually update their product and keep it at the cutting edge, the future looks bright - if you have the skills to harness it. In particular, new features such as remote desktop access, dynamic content caching and secure content delivery using SSL make the latest version of Azure a more powerful solution than ever before. It's widely agreed that cloud computing has produced a paradigm shift in traditional architectural concepts by providin

  10. Clinical outcomes after final kissing balloon inflation compared with no final kissing balloon inflation in bifurcation lesions treated with a dedicated coronary bifurcation stent.

    Science.gov (United States)

    Grundeken, Maik J; Lesiak, Maciej; Asgedom, Solomon; Garcia, Eulogio; Bethencourt, Armando; Norell, Michael S; Damman, Peter; Woudstra, Pier; Koch, Karel T; Vis, M Marije; Henriques, Jose P; Tijssen, Jan G; Onuma, Yoshinobu; Foley, David P; Bartorelli, Antonio L; Stella, Pieter R; de Winter, Robbert J; Wykrzykowska, Joanna J

    2014-03-01

    We evaluated differences in clinical outcomes between patients who underwent final kissing balloon inflation (FKBI) and patients who did not undergo FKBI in bifurcation treatment using the Tryton Side Branch Stent (Tryton Medical, Durham, North Carolina, USA). Clinical outcomes were defined as target vessel failure (composite of cardiac death, any myocardial infarction and clinically indicated target vessel revascularisation), cardiac death, myocardial infarction (MI), clinically indicated target vessel revascularisation and stent thrombosis. Cumulative event rates were estimated using the Kaplan-Meier method. A multivariable logistic regression analysis was performed to evaluate which factors were potentially associated with FKBI performance. Follow-up data was available in 717 (96%) patients with a median follow-up of 190 days. Cardiac death at 1 year occurred more often in the no-FKBI group (1.7% vs 4.6%, respectively, p=0.017), although this difference was no longer observed after excluding patients presenting with ST segment elevation MI (1.6% vs 3.3%, p=0.133). No significant differences were observed concerning the other clinical outcomes. One-year target vessel failure rates were 10.1% in the no-FKBI group and 9.2% in the FKBI group (p=0.257). Multivariable logistic regression analysis identified renal dysfunction, ST segment elevation MI as percutaneous coronary intervention indication, narrow (<30°) bifurcation angle and certain stent platforms as being independently associated with unsuccessful FKBI. A lower cardiac death rate was observed in patients in whom FKBI was performed compared with a selection of patients in whom FKBI could not be performed, probably explained by an unbalance in the baseline risk profile of the patients. No differences were observed regarding the other clinical outcomes.

  11. Sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer platform using the BSA-stabilized Au nanoclusters/amino-functionalized graphene oxide hybrids.

    Science.gov (United States)

    Lan, Jing; Zou, Hong Yan; Wang, Qiang; Zeng, Ping; Li, Yuan Fang; Huang, Cheng Zhi

    2016-12-01

    An ultra-sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer in the BSA-stabilized gold nanoclusters/amino-functionalized graphene oxide (BSA-AuNCs/NH 2 -GO) hybrids was successfully realized. The BSA-AuNCs containing amounts of carboxyl groups could be absorbed on the surface of NH 2 -GO through the electrostatic interaction, which resulted in the fluorescence quenching of BSA-AuNCs with high efficiency. However, heparin, possessing high density of negative charge, could compete with BSA-AuNCs to bind NH 2 -GO and block the energy transfer from BSA-AuNCs to NH 2 -GO. The fluorescence recovery of BSA-AuNCs was closely related to the amount of heparin and there was a good linear relationship between fluorescence recovery of BSA-AuNCs and heparin over the range of 100ng/mL to 30μg/mL with a detection limit of 40ng/mL. What's more, the fluorescence assay was successfully applied for heparin sensing in human serums and intracellular imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Games and Platform Decisions

    DEFF Research Database (Denmark)

    Hansen, Poul H. Kyvsgård; Mikkola, Juliana Hsuan

    2007-01-01

    is the application of on-line games in order to provide training for decision makers and in order to generate overview over the implications of platform decisions. However, games have to be placed in a context with other methods and we argue that a mixture of games, workshops, and simulations can provide improved...

  13. CERN Neutrino Platform Hardware

    CERN Document Server

    Nelson, Kevin

    2017-01-01

    My summer research was broadly in CERN's neutrino platform hardware efforts. This project had two main components: detector assembly and data analysis work for ICARUS. Specifically, I worked on assembly for the ProtoDUNE project and monitored the safety of ICARUS as it was transported to Fermilab by analyzing the accelerometer data from its move.

  14. Creative Platform Learning (CPL)

    DEFF Research Database (Denmark)

    Christensen, Jonna Langeland; Hansen, Søren

    Creative Platform Learning (CPL) er en pædagogisk metode, der skaber foretagsomme og innovative elever, der kan anvende deres kreativitet til at lære nyt. Ifølge den nye skolereform skal Innovation og entreprenørskab tydeliggøres i alle fag. I CPL er det en integreret del af undervisningen...

  15. Postgraduate programmes as platform

    NARCIS (Netherlands)

    drs Ben Smit; Dr. Jacqueline van Swet; Prof.Dr. Petra Ponte

    2007-01-01

    Typical of postgraduate courses for experienced teachers is the wealth of professional experience that the studetns bring with them. Such students can examine their own practice, for which they are fully responsible. Authors from diverse backgrounds address important aspects of the platform, such as

  16. Long-Duration Altitude-Controlled Balloons for Venus: A Feasibility Study Informed by Balloon Flights in Remote Environments on Earth

    Science.gov (United States)

    Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.

    2013-12-01

    In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon

  17. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.

    Science.gov (United States)

    Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H

    2013-05-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.

  18. Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry.

    Science.gov (United States)

    Lupi, Alessandro; Rognoni, Andrea; Schaffer, Alon; Secco, Gioel G; Bongo, Angelo S

    2015-01-01

    Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. We evaluated the safety and success rate of Mozec™ CTO balloon in 41 consecutive patients with chronic stable angina and complex coronary lesions (15 severe calcified coronary stenoses, 15 bifurcation lesions with planned two-stent intervention, and 11 CTOs). Safety was assessed reporting the balloon burst rate after inflation exceeding the rated burst pressure (RBP) according to the manufacturer's reference table. Success was defined as the possibility to advance the device further the target lesion. The Mozec™ CTO balloon showed an excellent performance with a 93.3% success in crossing tight and severely calcified lesions (14/15 pts), a 93.3% success in engaging jailed side branches after stent deployment across bifurcations (14/15 pts), and a 90.9% success in crossing CTO lesions (10/11 pts). The burst rate at RBP of the Mozec™ CTO balloon was 6.7% (1/15 balloons) in the tight and severely calcified lesions, 6.7% (1/15 balloons) when dilating jailed vessels, and 9.1% (1/11 balloons) in CTOs. The novel Mozec™ CTO balloon dilatation catheter showed promising results when employed to treat complex lesions in an all-comers population. Further studies should clarify if this kind of balloon might reduce the need of more costly devices like over-the-wire balloons and microcatheters for complex lesions treatment.

  19. Cable Stability

    CERN Document Server

    Bottura, L

    2014-01-01

    Superconductor stability is at the core of the design of any successful cable and magnet application. This chapter reviews the initial understanding of the stability mechanism, and reviews matters of importance for stability such as the nature and magnitude of the perturbation spectrum and the cooling mechanisms. Various stability strategies are studied, providing criteria that depend on the desired design and operating conditions.

  20. National Report Switzerland: Sounding Rocket and Balloon Activities and Related Research in Switzerland 2013-2015

    Science.gov (United States)

    Egli, M.

    2015-09-01

    During the period from 2013 to 2015, many Swiss researchers conducted studies on research platforms such as balloons or sounding rockets, or at the high altitude research stations of Jungfraujoch and Gornergrat. Researchers ‘ increased interest in sounding rockets during the two-year period is especially noteworthy. The use of the high altitude research stations, in contrast, has a long tradition in Switzerland and is, thus, frequently occupied by scientists. An advantage of these stations is the ideal set-up for researchers interested in the long-term measurement of the upper atmosphere, for example. Therefore, numcrous experiments in this particular research field were conducted and published in scientific journals. After a pause, several Swiss scientists became engaged in sounding rocket experiments. RUAG Space in Nyon, for instance, in collaboration with the Swedish Space Corporation (SSC) and University of Freiburg, is focusing on the effect of gravity on plant roots. In order to investigate a gravity-dependent influence, two experiments on Arabidopsis thaliana seedlings are being planned for execution during the upcoming MASTER 1 3 campaign. A team of students from HES-SO Geneva were chosen to participate in the REXUS program with their experiment called CAESAR. A new concept of a propellant management device for space vehicles was introduced and tested on the REXUS 14 rocket by the team from Geneva in the spring of 20 1 3 . Last year, another student team, now from the Lucerne University of Applied Sciences and Arts, was selected to fly their experiment on another REXUS rocket. Their proposed biological study is called CEMIOS and pertains to biochemical properties of the cell membrane. Once more the high altitude research stations of Jungfraujoch and Gornergrat welcomed many national—as well as international—scientists in the past two years. The hours that the researchers spent in either station reached a record high despite the poor weather conditions

  1. Computational Model of Drug-Coated Balloon Delivery in a Patient-Specific Arterial Vessel with Heterogeneous Tissue Composition.

    Science.gov (United States)

    Mandal, Prashanta K; Sarifuddin; Kolachalama, Vijaya B

    2016-12-01

    Balloon angioplasty followed by local delivery of antiproliferative drugs to target tissue is increasingly being considered for the treatment of obstructive arterial disease, and yet there is much to appreciate regarding pharmacokinetics in arteries of non-uniform disease. We developed a computational model capable of simulating drug-coated balloon delivery to arteries of heterogeneous tissue composition comprising healthy tissue, as well as regions of fibrous, fibro-fatty, calcified and necrotic core lesions. Image processing using an unsupervised clustering technique was used to reconstruct an arterial geometry from a single, patient-specific color image obtained from intravascular ultrasound-derived virtual histology. Transport of free drug was modeled using a time-dependent reaction-diffusion model and the bound, immobilized drug using the time-dependent reaction equation. The governing equations representing the transport of free as well as bound drug along with a set of initial settings and boundary conditions were solved numerically using an explicit finite difference scheme that satisfied the Courant-Friedrichs-Lewy stability criterion. Our results support previous findings related to the transport and binding of drug in arteries where tissue retention is strongly dependent on local pharmacologic properties. Additionally, modeling results indicate that non-uniform disease composition leads to heterogeneous arterial drug distribution patterns, although further validation using animal studies is required to fully appreciate pharmacokinetics in disease-laden arteries.

  2. A device for performing automated balloon catheter inflation ischemia studies.

    Science.gov (United States)

    Leavesley, Silas J; Ledkins, Whitley; Rocic, Petra

    2014-01-01

    Coronary collateral growth (arteriogenesis) is a physiological adaptive response to transient and repetitive occlusion of major coronary arteries in which small arterioles (native collaterals) with minimal to no blood flow remodel into larger conduit arteries capable of supplying adequate perfusion to tissue distal to the site of occlusion. The ability to reliably and reproducibly mimic transient, repetitive coronary artery occlusion (ischemia) in animal models is critical to the development of therapies to restore coronary collateral development in type II diabetes and the metabolic syndrome. Current animal models for repetitive coronary artery occlusion implement a pneumatic occluder (balloon) that is secured onto the surface of the heart with the suture, which is inflated manually, via a catheter connected to syringe, to effect occlusion of the left anterior descending coronary artery (LAD). This method, although effective, presents complications in terms of reproducibility and practicality. To address these limitations, we have designed a device for automated, transient inflation of balloon catheters in coronary artery occlusion models. This device allows repeated, consistent inflation (to either specified pressure or volume) and the capability for implementing very complex, month-long protocols. This system has significantly increased the reproducibility of coronary collateral growth studies in our laboratory, resulting in a significant decrease in the numbers of animals needed to complete each study while relieving laboratory personnel from the burden of extra working hours and enabling us to continue studies over periods when we previously could not. In this paper, we present all details necessary for construction and operation of the inflator. In addition, all of the components for this device are commercially available and economical (Table S1). It is our hope that the adoption of automated balloon catheter inflation protocols will improve the experimental

  3. Biogenic nonmethane hydrocarbon emissions estimated from tethered balloon observations

    Science.gov (United States)

    Davis, K. J.; Lenschow, D. H.; Zimmerman, P. R.

    1994-01-01

    A new technique for estimating surface fluxes of trace gases, the mixed-layer gradient technique, is used to calculate isoprene and terpene emissions from forests. The technique is applied to tethered balloon measurements made over the Amazon forest and a pine-oak forest in Alabama at altitudes up to 300 m. The observations were made during the dry season Amazon Boundary Layer Experiment (ABLE 2A) and the Rural Oxidants in the Southern Environment 1990 experiment (ROSE I). Results from large eddy simulations of scalar transport in the clear convective boundary layer are used to infer fluxes from the balloon profiles. Profiles from the Amazon give a mean daytime emission of 3630 +/- 1400 micrograms isoprene sq m/h, where the uncertainty represents the standard deviation of the mean of eight flux estimates. Twenty profiles from Alabama give emissions of 4470 +/- 3300 micrograms isoprene sq m/h, 1740 +/- 1060 micrograms alpha-pinene sq m/h, and 790 +/- 560 micrograms beta-pinene sq m/h, respectively. These results are in agreement with emissions derived from chemical budgets. The emissions may be overestimated because of uncertainty about how to incorporate the effects of the canopy on the mixed-layer gradients. The large variability in these emission estimates is probably due to the relatively short sampling times of the balloon profiles, though spatially heterogeneous emissions may also play a role. Fluxes derived using this technique are representative of an upwind footprint of several kilometers and are independent of hydrocarbon oxidation rate and mean advection.

  4. A device for performing automated balloon catheter inflation ischemia studies.

    Directory of Open Access Journals (Sweden)

    Silas J Leavesley

    Full Text Available Coronary collateral growth (arteriogenesis is a physiological adaptive response to transient and repetitive occlusion of major coronary arteries in which small arterioles (native collaterals with minimal to no blood flow remodel into larger conduit arteries capable of supplying adequate perfusion to tissue distal to the site of occlusion. The ability to reliably and reproducibly mimic transient, repetitive coronary artery occlusion (ischemia in animal models is critical to the development of therapies to restore coronary collateral development in type II diabetes and the metabolic syndrome. Current animal models for repetitive coronary artery occlusion implement a pneumatic occluder (balloon that is secured onto the surface of the heart with the suture, which is inflated manually, via a catheter connected to syringe, to effect occlusion of the left anterior descending coronary artery (LAD. This method, although effective, presents complications in terms of reproducibility and practicality. To address these limitations, we have designed a device for automated, transient inflation of balloon catheters in coronary artery occlusion models. This device allows repeated, consistent inflation (to either specified pressure or volume and the capability for implementing very complex, month-long protocols. This system has significantly increased the reproducibility of coronary collateral growth studies in our laboratory, resulting in a significant decrease in the numbers of animals needed to complete each study while relieving laboratory personnel from the burden of extra working hours and enabling us to continue studies over periods when we previously could not. In this paper, we present all details necessary for construction and operation of the inflator. In addition, all of the components for this device are commercially available and economical (Table S1. It is our hope that the adoption of automated balloon catheter inflation protocols will improve the

  5. Aluminum Micro-Balloons as Improved Fuel for Warhead Explosives

    Science.gov (United States)

    2018-01-29

    8725 John J. Kingman Road , MS 6201 Fort Belvoir, VA 22060-6201 T E C H N IC A L R E P O R T DTRA-TR-16-11 Aluminum Micro-Balloons as... ROAD , MS-6201, FT BELVOIR, VA 22060-6201, IF YOUR ADDRESS IS INCORRECT, IF YOU WISH IT DELETED FROM THE DISTRIBUTION LIST, OR IF THE ADDRESSEE...active in getting aluminum particles with oxide coatings to react with water under shock loading as reported in the literature. It is useful to note

  6. Cineangiographic findings and balloon catheter angioplasty of pulmonic valvular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Yoon, Yong Soo; Kim, In One; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-08-15

    Transluminal balloon valvuloplasty was performed in the treatment of congenital pulmonic valvular stenosis in 55 children, aged 4 months to 15 years. The right ventricular outflow tract pressure gradient decreased significantly immediately after the procedure from 87.18 {+-} 56mmHg to 29.62 {+-} 26.48mmHg ({rho} < 0.001). Technical success rate was 98% (54/55 patients) and failed case (1 patient) was due to severe fibrous thickening of valve. Complication occurred in one case, that is tricuspid regurgitation (Grade II) due to suspected rupture of chordae tendinae. The degree of pulmonary conus dilatation was closely related with age than the pressure gradient.

  7. Mobile Platforms and Development Environments

    CERN Document Server

    Helal, Sumi; Li, Wengdong

    2012-01-01

    Mobile platform development has lately become a technological war zone with extremely dynamic and fluid movement, especially in the smart phone and tablet market space. This Synthesis lecture is a guide to the latest developments of the key mobile platforms that are shaping the mobile platform industry. The book covers the three currently dominant native platforms -- iOS, Android and Windows Phone -- along with the device-agnostic HTML5 mobile web platform. The lecture also covers location-based services (LBS) which can be considered as a platform in its own right. The lecture utilizes a sampl

  8. Platform Performance and Challenges - using Platforms in Lego Company

    DEFF Research Database (Denmark)

    Munk, Lone; Mortensen, Niels Henrik

    2009-01-01

    This article studies the performance and challenges of using nine implemented product platforms in LEGO Company. Most of these do produce results, but do not meet their goals due to challenges in their usage in the daily product. The main challenges are that the platforms are not being used...... by the product defining users (product developers) and platform erosion. When the platforms are not used it is due to: unsuitable calculation models, lack of goals, rewards or benefits from management, unattractive tradeoffs and difficulties in understanding the platform. This indicates that platform design...... needs focus on the incentive of using the platform. This problem lacks attention in literature, as well as industry, where assessment criteria do not cover this aspect. Therefore, we recommend including user incentive in platform assessment criteria to these challenges. Concrete solution elements...

  9. Balloon Kyphoplasty for Refractory Vertebral Compression Fractures in a Growing Child With Duchenne Muscular Dystrophy With Five-Year Follow-Up: Case Report and Review of Literature.

    Science.gov (United States)

    Duncan, Jan William; Bailey, Richard Anthony

    2014-03-01

    Presentation of previously unreported results and 5-year follow-up of balloon kyphoplasty used to treat an 8-year-old patient with refractory vertebral compression fractures resulting from 3 years of corticosteroid treatment for Duchenne muscular dystrophy. Long-term corticosteroid treatment in patients with DMD has been used to try and improve muscle strength, prolong ambulation, and lower the prevalence of scoliosis. However, these patients have an increased risk of osteoporosis and vertebral fractures. The patient was an 8-year-old boy with Duchenne muscular dystrophy who had received corticosteroid treatment for 3 years, with refractory vertebral compression fractures at T11, L1, and L3. Balloon kyphoplasty was performed at the 3 vertebral bodies using careful technique. The patient achieved immediate pain relief after the procedure. The height of the treated vertebrae remained stable without further collapse over a 5-year follow-up period. At 5-year follow-up, the patient developed 2 new vertebral compression fractures at T12 and L2 adjacent to the treated vertebrae. The treatment also did not affect the growth of the treated vertebrae or the patient's overall growth. Because the procedure resulted in rapid stabilization of the treated vertebrae, effective analgesia, and no effect on the growth of the treated vertebrae over a 5-year follow-up period, balloon kyphoplasty was a good therapeutic option for this pediatric patient. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  10. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  11. Solar energy collector including a weightless balloon with sun tracking means

    Science.gov (United States)

    Hall, Frederick F.

    1978-01-01

    A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.

  12. Endoscopic balloon dilatation as treatment of gastric outlet obstruction in infancy and childhood

    NARCIS (Netherlands)

    Heymans, H. S.; Bartelsman, J. W.; Herweijer, T. J.

    1988-01-01

    The application of balloon dilatation as treatment of gastric outlet obstruction is described. In two infants after inadequate pyloromyotomy and in an 11-year-old boy with surgical damage to the vagus, balloon dilatation was successful and considered a good alternative to surgery in these conditions

  13. Feasibility of Balloon-Borne Optical Measurement of (C sub n) Squared.

    Science.gov (United States)

    1981-10-26

    attached to two meteorological balloons. Tether lines to the balloons are attached to a trailing package which contains a telemetry trasmitter and...R.J. Cook, Beam wander in a turbulent medium: An application of Ehrenfest’s theorem, J. Opt. Soc. Am ., 1975, 8, 942. 28 DAT FILM

  14. Adjustable intragastric balloons: a 12-month pilot trial in endoscopic weight loss management

    NARCIS (Netherlands)

    Machytka, Evzen; Klvana, Pavel; Kornbluth, Asher; Peikin, Steven; Mathus-Vliegen, Lisbeth E. M.; Gostout, Christopher; Lopez-Nava, Gontrand; Shikora, Scott; Brooks, Jeffrey

    2011-01-01

    Intragastric balloons are associated with (1) early period intolerance, (2) diminished effect within 3-4 months, and (3) bowel obstruction risk mandating removal at 6 months. The introduction of an adjustable balloon could improve comfort and offer greater efficacy. A migration prevention function,

  15. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...... of this retrospective study was to report outcomes after cutting balloon angioplasty (CBA) of cephalic arch stenosis....

  16. Membranous duodenal stenosis: initial experience with balloon dilatation in four children

    NARCIS (Netherlands)

    van Rijn, R. R.; van Lienden, K. P.; Fortuna, T. L.; D'Alessandro, L. C. A.; Connolly, B.; Chait, P. G.

    2006-01-01

    INTRODUCTION: We present a novel approach to the treatment of membranous duodenal stenosis (MDS). To our knowledge this is the first paper to describe balloon dilatation for this entity. MATERIAL AND METHODS: Four children, 2 boys and 2 girls, aged between 8 and 28 days, underwent duodenal balloon

  17. Single-centre comparison of a novel single-step balloon inflation ...

    African Journals Online (AJOL)

    Objective. A new second-generation balloon dilatation device for percutaneous nephrolithotomy (PCNL) has been launched, promising to challenge the traditional Amplatz serial dilators (ASDs). This device allows for the polyurethane sheath to be deployed on balloon inflation. Our primary objective in this pilot study was to ...

  18. Goldvalve detachable balloon: ''in vitro'' assessment of safety and imaging artifacts in a 3-T MR system

    International Nuclear Information System (INIS)

    Dabus, Guilherme; Gerstle, Ronald J.; Goodman, James; Cross, Witte T. de; Moran, Christopher J.; Derdeyn, Colin P.

    2006-01-01

    The Goldvalve balloon is the only currently available detachable balloon. We undertook a study to determine safety and imaging artifacts in a MR environment. We found no evidence for heating or deflection of the balloon in a comprehensive series of in vitro experiments at 3 T. MR imaging at field strengths up to 3 T of patients with implanted Goldvalve balloons is safe. Imaging artifacts are minimal. (orig.)

  19. Design of Meteorological Element Detection Platform for Atmospheric Boundary Layer Based on UAV

    Directory of Open Access Journals (Sweden)

    Yonghong Zhang

    2017-01-01

    Full Text Available Among current detection methods of the atmospheric boundary layer, sounding balloon has disadvantages such as low recovery and low reuse rate, anemometer tower has disadvantages such as fixed location and high cost, and remote sensing detection has disadvantages such as low data accuracy. In this paper, a meteorological element sensor was carried on a six-rotor UAV platform to achieve detection of meteorological elements of the atmospheric boundary layer, and the influence of different installation positions of the meteorological element sensor on the detection accuracy of the meteorological element sensor was analyzed through many experiments. Firstly, a six-rotor UAV platform was built through mechanical structure design and control system design. Secondly, data such as temperature, relative humidity, pressure, elevation, and latitude and longitude were collected by designing a meteorological element detection system. Thirdly, data management of the collected data was conducted, including local storage and real-time display on ground host computer. Finally, combined with the comprehensive analysis of the data of automatic weather station, the validity of the data was verified. This six-rotor UAV platform carrying a meteorological element sensor can effectively realize the direct measurement of the atmospheric boundary layer and in some cases can make up for the deficiency of sounding balloon, anemometer tower, and remote sensing detection.

  20. Schematics of a Water Balloon Launcher Design and Reproducible Water-Balloon-Filling Procedures Used for a Middle School Summer Science Camp

    OpenAIRE

    Christiansen, Mike A; Edwards, Boyd F.; Sam, David D.

    2013-01-01

    We recently held a Science Summer Camp for middle school students, designed to infuse young people with increased excitement for STEM (Science, Technology, Engineering, and Math) subjects. Our efforts, which received nationally-syndicated news coverage,1 included the invention of a versatile water balloon launcher. This document contains: (1) detailed construction schematics and user operation guidelines for our balloon launcher; (2) data and instructions for reproducibly filling ...

  1. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.

    Science.gov (United States)

    Arai, Takahide; Hovasse, Thomas; Chevalier, Bernard

    2018-04-01

    The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Available: motorised platform

    CERN Multimedia

    The COMPASS collaboration

    2014-01-01

    The COMPASS collaboration would like to offer to a new owner the following useful and fully operational piece of equipment, which is due to be replaced with better adapted equipment.   Please contact Erwin Bielert (erwin.bielert@cern.ch or 160539) for further information.  Motorized platform (FOR FREE):   Fabricated by ACL (Alfredo Cardoso & Cia Ltd) in Portugal. The model number is MeXs 5-­‐30.  Specifications: 5 m wide, 1 m deep, adjustable height (1.5 m if folded). Maximum working floor height: 4 m. conforms to CERN regulations, number LV158. Type LD500, capacity 500 kg and weight 2000 kg.  If no interested party is found before December 2014, the platform will be thrown away.

  3. Online stock trading platform

    Directory of Open Access Journals (Sweden)

    Ion LUNGU

    2006-01-01

    Full Text Available The Internet is the perfect tool that can assure the market’s transparency for any user who wants to trade on the stock market. The investor can have access to the market news, financial calendar or the press releases of the issuers. A good online trading platform also provides real-time intraday quotes, trading history and technical analysis giving the investor a clearer view of the supply and demand in the market. All this information provides the investor a good image of the market and encourages him to trade. This paper wishes to draft the pieces of an online trading platform and to analyze the impact of developing and implementing one in a brokerage firm.

  4. Common tester platform concept.

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, Michael James

    2008-05-01

    This report summarizes the results of a case study on the doctrine of a common tester platform, a concept of a standardized platform that can be applicable across the broad spectrum of testing requirements throughout the various stages of a weapons program, as well as across the various weapons programs. The common tester concept strives to define an affordable, next-generation design that will meet testing requirements with the flexibility to grow and expand; supporting the initial development stages of a weapons program through to the final production and surveillance stages. This report discusses a concept investing key leveraging technologies and operational concepts combined with prototype tester-development experiences and practical lessons learned gleaned from past weapons programs.

  5. MHD simulation of high wavenumber ballooning-like modes in LHD

    International Nuclear Information System (INIS)

    Miura, H.; Nakajima, N.

    2008-10-01

    Dynamical growths of high-wavenumber ballooning modes are studied through full-3D nonlinear MHD simulations of the Large Helical Device. The growths of the ballooning modes are identified by studying the growth rates and the radial profiles of the Fourier coefficients of fluctuation variables. The mechanisms to weaken the growth of instability, such as the local fattening of the pressure and the energy release to the parallel kinetic energy, are found being insufficient to suppress the high-wavenumber ballooning modes. Consequently, the mean pressure profile is totally modified when the evolutions of the ballooning modes are saturated. The numerical results reveal that we need some mechanisms which do not originate from an ideal MHD to achieve a mild, saturated behaviors beyond the growths of unstable high ballooning modes in the helical device. The parallel heat conductivity is proposed as one of possible non-ideal mechanisms. (author)

  6. Impact of balloon inflation pressure on cell viability with single and multi lumen catheters.

    Science.gov (United States)

    Dib, N; Schwalbach, D B; Plourde, B D; Kohler, R E; Dana, D; Abraham, J P

    2014-12-01

    Infusion catheters, when used in combination with balloons, are subjected to pressure created by inflation of the balloon. The compression can reduce the catheter flow area and cause elevated shear stresses in the fluid. A model and experiments were developed with a range of applied balloon pressures to investigate whether such situations may cause cell lysis during stem-cell infusion through single-lumen catheters. It was found that for balloon inflation pressures in excess of ~7 atm, it is possible for cell injury to occur, although the critical pressure depends on the fluid viscosity. The study was then applied to a multi-lumen catheter which was designed to resist compression. That device was able to handle very elevated balloon pressures and flow rates before cell lysis became a concern.

  7. Rupture of the Renal Artery After Cutting Balloon Angioplasty in a Young Woman With Fibromuscular Dysplasia

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Gulcan, Oner; Turkoz, Riza

    2005-01-01

    A 24-year-old woman with uncontrollable high blood pressure for 3 months had significant stenosis of the left renal artery caused by fibromuscular dysplasia (FMD). The lesion was resistant to percutaneous transluminal angioplasty at 18 atm with a semicompliant balloon. Angioplasy with a 6 x 10 mm cutting balloon (CB) caused rupture of the artery. Low-pressure balloon inflation decreased but did not stop the leak. An attempt to place a stent-graft (Jostent; Jomed, Rangendingen, Germany) failed, and a bare, 6-mm balloon-expandable stent (Express SD; Boston Scientific, MN) was deployed to seal the leak, which had decreased considerably after long-duration balloon inflation. The bleeding continued, and the patient underwent emergent surgical revascularization of the renal artery with successful placement of a 6-mm polytetrafluoroethylene bypass graft. CBs should be used very carefully in the treatment of renal artery stenosis, particularly in patients with FMD

  8. HPC - Platforms Penta Chart

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo, Angelina Michelle [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-08

    Strategy, Planning, Acquiring- very large scale computing platforms come and go and planning for immensely scalable machines often precedes actual procurement by 3 years. Procurement can be another year or more. Integration- After Acquisition, machines must be integrated into the computing environments at LANL. Connection to scalable storage via large scale storage networking, assuring correct and secure operations. Management and Utilization – Ongoing operations, maintenance, and trouble shooting of the hardware and systems software at massive scale is required.

  9. Virtual interconnection platform initiative scoping study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kou, Gefei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pan, Zuohong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Yilu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); King Jr., Thomas J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-01-01

    Due to security and liability concerns, the research community has limited access to realistic large-scale power grid models to test and validate new operation and control methodologies. It is also difficult for industry to evaluate the relative value of competing new tools without a common platform for comparison. This report proposes to develop a large-scale virtual power grid model that retains basic features and represents future trends of major U.S. electric interconnections. This model will include realistic power flow and dynamics information as well as a relevant geospatial distribution of assets. This model will be made widely available to the research community for various power system stability and control studies and can be used as a common platform for comparing the efficacies of various new technologies.

  10. Current status of endoscopic balloon dilation for Crohn's disease

    Directory of Open Access Journals (Sweden)

    Fumihito Hirai

    2017-04-01

    Full Text Available The therapeutic target in Crohn's disease (CD has been raised to the achievement of mucosal healing. Although effective treatments that target cytokines and other molecules has been widely used for CD, intestinal strictures are still a major cause of surgery. Endoscopic balloon dilation (EBD is known to be an effective and safe intervention for intestinal strictures in CD. Since frequent intestinal resection often results in short bowel syndrome and can decrease the quality of life, EBD can help avoid surgery. EBD with a conventional colonoscope for Crohn's strictures of the colon and ileo-colonic anastomosis has established efficacy and safety. In addition, EBD using balloon-assisted enteroscopy has recently been applied for small bowel Crohn's strictures. Although the evidence is not strong, EBD may become an alternative to surgery in small bowel strictures in CD. EBD and other new methods such as self-expanding stent implantation for Crohn's strictures may be useful and safe; however, it is important to address several issues regarding these interventions and to establish a protocol for combined therapies.

  11. Electron observation with the balloon-borne CALET prototype detector

    Science.gov (United States)

    Torii, Shoji; Ozawa, Shunsuke; Kasahara, Katsuaki; Murakami, Hiroyuki; Akaike, Yosui; Aiba, Toshihide; Ueyama, Yoshitaka; Nakai, Mikio; Kai, Yuuichirou; Tamura, Tadahisa; Yoshida, Kenji; Katayose, Yusaku; Kawada, Jiro; Mizuta, Eiichi; Marrocchesi, Pier Simone; Kim, Meyoung; Bigongiari, Gabriele

    We have been carrying out an observation of the cosmic ray electrons, using the CALET prototype detector: bCALET. After the first flight of bCALET-1, the bCALET-2 was flown in 2009 at the JAXA balloon center at Taikicho for observing the electrons in 1-100 GeV. The detector is composed IMaging Calorimeter(IMC), Total AbSorption Calorimeter(TASC). IMC has an area of 256mmx256mm, and is consisted 8 layers of scintillating fiber belts intserted below tungsten plate (3 r.l. in total) for a fine imaging of shower particles. TASC is made 6 layers of BGO scintillator logs (25mm x 25mm x 300 mm in each) with an active area of 250mm x 250mm, for measurement the total energy deposit of incoming shower particles. The observation was successfully carried out, and the basic performance of the detector was confirmed to be consistent with the expectation by simulations. We will have the third flight of the bCALET-3 in 2010 at the Balloon Launch Center of Cachoeira Paulista in Brazil, to extend the energy region up to 1000 GeV. We will present the results of the bCALET-2 and the RD of the bCALET-3 detector.

  12. Barrage balloons against aircraft threat: A well proven concept revisited

    International Nuclear Information System (INIS)

    Petrangeli, Gianni

    2010-01-01

    Since the event of September 11, 2001 in New York City, many people started to speculate that the same type of attack could in future be brought against other installations. Indeed, the U.S. Nuclear Regulatory Commission decided to require for future plants to assess their resistance to the impact of a large civil airliner. Nuclear plant control authorities of other countries decided in a similar direction. The solutions to the technical problem is usually pursued in the direction of a reinforcement of external plant structures and, in some case, they may not be sufficient. Other solutions of more psychological nature have also been adopted. This paper aims at the demonstration that the use of barrage balloons, already adopted with success in both World Wars and also occasionally after these events, can afford a satisfactory solution to the protection problem at a reasonable cost. This solution is also applicable to existing plants. The history of barrage balloons is summarized. Modern technology offers electronic devices capable to detect in time an approaching threat and the paper describes a new barrage system based also on such new possibilities. If the aircraft crash problem is a real one or not for the next years, nobody knows for sure; however some considerations should be kept in mind: ·The fact that an accident of this kind 'anywhere' is an accident 'everywhere' as usual; ·The extremely uncertain political outlook worldwide, the peculiarities of the oil market and the possible nuclear renaissance.

  13. Balloon sinuplasty: a new concept in the endoscopic nasal surgery

    Directory of Open Access Journals (Sweden)

    Nogueira Júnior, João Flávio

    2008-12-01

    Full Text Available Introduction: Sinus diseases affect millions of people annually. Clinical treatment is effective in most patients, but in case of failure of this therapy the functional endoscopic surgery is currently the treatment choice for surgical treatment. The objective of the functional endoscopic surgery is to increase the aeration and drainage of the involved paranasal sinuses, which allows for the adequate functioning of the nasal mucosa mucociliary clearance. However, this method still has some limitations, mainly because it removes the nasal mucosa and bone tissue, and it may lead to physiologic alterations of the nasosinusal mucosa and cicatricial fibrosis. Many of these patients could be benefited from less invasive methods, with larger nasal mucosa preservation. Since 2006, an even less invasive procedure was remarked in our specialty: the balloon dilatation of the paranasal sinus ostia. Objective: The objective of this article is to define the concept of sinuplasty, its action mechanism, and present the necessary material for the procedures performance; to describe the techniques with the equipment in a nasosinusal endoscopic surgery simulator model and review the current literature about the indications, complications, results, and follow-up of patients submitted to this procedure. Balloon sinuplasty is safe and appears to be effective in the improvement of the quality of life of patients not responsive to conventional clinical therapy. New applications and indications for this equipment should be described and researched.

  14. Beam Tests of the Balloon-Borne ATIC Experiment

    Science.gov (United States)

    Ganel, O.; Adams, J. H., Jr.; Ahn, E. J.; Ampe, J.; Bashindzhagyan, G.; Case, G.; Chang, J.; Ellison, S.; Fazely, A.; Gould, R.

    2003-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurement from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide crucial hints about some of the most fundamental questions in astroparticle physics today. ATTIC'S design centers on an 18 radiation length (X(sub Omnicron)) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75 lambda(sub int) graphite target. In September 1999 the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator, within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000 - January 2001, ATIC flew on the first of a series of long duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam-tests, including energy resolutions for electrons and protons at several beam energies from 100 GeV to 375 GeV, as well as signal linearity and collection efficiency estimates. We show how these results compare with expectations based on simulations, and their expected impacts on mission performance.

  15. Treatment of urethral strictures with balloon dilation: A forgotten tale

    Directory of Open Access Journals (Sweden)

    Konstantinos Stamatiou

    2015-09-01

    Full Text Available Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization and dilation, urethroplasty and endoscopic internal urethrotomy as well. Although treatment option depends on the type, length and aetiology of stricture, the choice can be influenced to varying degrees by the simplicity of the method, the preferences of the patient the available accoutrements and the patient health condition. Both urethroplasty and endoscopic internal urethrotomy require anaesthesia and thus are not suitable for many elder and unfit for surgical treatment patients. On the other hand, dilations are easy to perform in every day clinical practice however they have been associated with iatrogenic urethral trauma. In contrast, balloon dilation under vision dilates by radial application of forces against the stricture, avoiding the potentially shearing forces associated with sequential rigid dilation. Since it reduces the possibility of an iatrogenic urethral trauma and the subsequent spongiofibrosis may lead into improved therapeutic outcomes. In this report we describe a technique for the treatment of urethral strictures with balloon dilation in elder and unfit for surgical treatment patients.

  16. Polar Balloon Experiment for Astrophysics Research (Polar BEAR)

    Science.gov (United States)

    Bashindzhagyan, G.; Adams, James H., Jr.; Bashindzhagyan, P.; Chilingarian, A.; Donnelly, J.; Drury, L.; Egorov, N.; Golubkov, S.; Grebenyuk, V.; Kalinin, A.; hide

    2001-01-01

    A new balloon experiment is proposed for a long duration flight around the North Pole. The primary objective of the experiment is to measure the elemental energy spectra of high-energy cosmic rays in the region up to 10(exp 15) eV. The proposed instrument involves the combination of a large collecting area (approximately 1 x 1 square m) KLEM (Kinematic Lightweight Energy Meter) device with an ionization calorimeter having a smaller collecting area (approximately 0.5 x 0.5 square m) and integrated beneath the KLEM apparatus. This combination has several important advantages. Due to the large aperture (greater than 2 square m sr) of the KLEM device a large exposure factor can be achieved with a long duration balloon flight (2-4 weeks). The calorimeter will collect about 10% of the events already registered by KLEM and provide effective cross-calibration for both energy measurement methods. Details of the experiment and its astrophysical significance will be presented.

  17. Beam tests of the balloon-borne ATIC experiment

    CERN Document Server

    Ganel, O; Ahn, H S; Ampe, J; Bashindzhagian, G L; Case, G; Chang, H; Ellison, S; Fazely, A; Gould, R; Granger, D; Gunasingha, R M; Guzik, T G; Han, Y J; Isbert, J; Kim, H J; Kim, K C; Kim, S K; Kwon, Y; Panasyuk, M Y; Panov, A; Price, B; Samsonov, G; Schmidt, W K H; Sen, M; Seo, E S; Sina, R; Sokolskaya, N; Stewart, M; Voronin, A; Wagner, D; Wang, J Z; Wefel, J P; Wu, J; Zatsepin, V

    2005-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurements from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide information about some of the most fundamental questions in astroparticle physics today. ATIC's design centers on an 18 radiation length (X0) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75λint graphite target. In September 1999, the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000–January 2001 and again in December 2002–January 2003, ATIC flew on the first two of a series of long-duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam tests, including energy resolutions for electrons and protons at several beam energies from 100 to 375 G...

  18. The Prodiguer Messaging Platform

    Science.gov (United States)

    Denvil, S.; Greenslade, M. A.; Carenton, N.; Levavasseur, G.; Raciazek, J.

    2015-12-01

    CONVERGENCE is a French multi-partner national project designed to gather HPC and informatics expertise to innovate in the context of running French global climate models with differing grids and at differing resolutions. Efficient and reliable execution of these models and the management and dissemination of model output are some of the complexities that CONVERGENCE aims to resolve.At any one moment in time, researchers affiliated with the Institut Pierre Simon Laplace (IPSL) climate modeling group, are running hundreds of global climate simulations. These simulations execute upon a heterogeneous set of French High Performance Computing (HPC) environments. The IPSL's simulation execution runtime libIGCM (library for IPSL Global Climate Modeling group) has recently been enhanced so as to support hitherto impossible realtime use cases such as simulation monitoring, data publication, metrics collection, simulation control, visualizations … etc. At the core of this enhancement is Prodiguer: an AMQP (Advanced Message Queue Protocol) based event driven asynchronous distributed messaging platform. libIGCM now dispatches copious amounts of information, in the form of messages, to the platform for remote processing by Prodiguer software agents at IPSL servers in Paris. Such processing takes several forms: Persisting message content to database(s); Launching rollback jobs upon simulation failure; Notifying downstream applications; Automation of visualization pipelines; We will describe and/or demonstrate the platform's: Technical implementation; Inherent ease of scalability; Inherent adaptiveness in respect to supervising simulations; Web portal receiving simulation notifications in realtime.

  19. "Platform switching": Serendipity

    Directory of Open Access Journals (Sweden)

    N Kalavathy

    2014-01-01

    Full Text Available Implant dentistry is the latest developing field in terms of clinical techniques, research, material science and oral rehabilitation. Extensive work is being done to improve the designing of implants in order to achieve better esthetics and function. The main drawback with respect to implant restoration is achieving good osseointegration along with satisfactory stress distribution, which in turn will improve the prognosis of implant prosthesis by reducing the crestal bone loss. Many concepts have been developed with reference to surface coating of implants, surgical techniques for implant placement, immediate and delayed loading, platform switching concept, etc. This article has made an attempt to review the concept of platform switching was in fact revealed accidentally due to the nonavailability of the abutment appropriate to the size of the implant placed. A few aspect of platform switching, an upcoming idea to reduce crestal bone loss have been covered. The various methods used for locating and preparing the data were done through textbooks, Google search and related articles.

  20. Finite-Larmor-radius stability theory of EBT plasmas

    International Nuclear Information System (INIS)

    Berk, H.L.; Cheng, C.Z.; Rosenbluth, M.N.; Van Dam, J.W.

    1982-11-01

    An eikonal ballooning-mode formalism is developed to describe curvature-driven modes of hot electron plasmas in bumpy tori. The formalism treats frequencies comparable to the ion-cyclotron frequency, as well as arbitrary finite Larmor radius and field polarization, although the detailed analysis is restricted to E/sub parallel/ = 0. Moderate hot-electron finite-Larmor-radius effects are found to lower the background beta core limit, whereas strong finite-Lamor-radius effects produce stabilization

  1. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Directory of Open Access Journals (Sweden)

    Hee Young Cho

    Full Text Available The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation.We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL.Sixty-four patients (46.7% required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1% had placenta previa totalis. The overall success rate was 75% (48/64 for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05. The drainage amount over 1 hour was 500 mL (20-1200 mL in the balloon failure group and 60 mL (5-500 mL in the balloon success group (p<0.01.Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  2. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  3. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity

    Directory of Open Access Journals (Sweden)

    M.ª Luisa de Castro

    2013-10-01

    Full Text Available Introduction: intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. Material and methods: from May 2004 to June 2011 91 obese patients, body mass index [BMI] 45.2 ± 7.2 kg/m² were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW ≥ 5% at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values < 0.05. Results: we placed 73 fluid-filled balloons (80.2% and 18 air-filled ones (19.8%. Compared to baseline values, at 6-month 73.7% subjects succeeded, showing significant reductions in weight (13.3 ± 8.8 kg, BMI (5 ± 3.4 kg/m² (p < 0.0001, with% LTW 11 ± 7%. Six and twelve months after retrieval 45.1% and 28.6% patients reached% LTW ≥ 5%. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04. Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001. Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005. Conclusions: in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time. Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  4. Kajian Teknologi High Altitude Platform (HAP [Study of High Altitude Platform (HAP Technology

    Directory of Open Access Journals (Sweden)

    Amry Daulat Gultom

    2016-07-01

    Full Text Available High Altitude Platform (HAP merupakan solusi alternatif untuk mengatasi keterbatasan infrastruktur terestrial maupun satelit. HAP merupakan pesawat ataupun balon udara yang ditempatkan pada ketinggian 20-50 km di atas permukaan bumi. Kelebihan yang utama dari HAP adalah kemudahan dalam penempatan, fleksibilitas, biaya operasionalnya rendah, delay  propagasi rendah, sudut elevasi lebar, cakupan yang luas. Penelitian ini dilakukan untuk mengetahui potensi HAP untuk komunikasi pita lebar dan perkembangannya di Indonesia. Analisis dilakukan secara deskriptif dengan mengolah data literatur yang didapat. Hasil penelitian menunjukkan bahwa di Indonesia terdapat potensi teknologi HAP untuk komunikasi pita lebar dengan lebar pita 2x300 MHz di band 27,9-28,2 GHz dan 31-31,3 GHz. Namun, belum ada peraturan yang mengatur alokasi frekuensi untuk HAP secara khusus di Indonesia.*****High Altitude Platform (HAP has been developed as an alternative solution in order to overcome limitation of terrestrial and satellite communication system. HAP is an aircraft or balloon situated on 20-50 km above the earth. Main advantages of HAP are flexibility in deployment, low propagation delay, wide elevation angle and broad coverage. The research is conducted to gather HAP potential for broadband communication and its development in Indonesia. Analysis is conducted by descriptive analysis from literature study gather. The research result shows that in Indonesia, there is potential of HAP technology for broadband communication with 2x300 MHz bandwidth within 27,9-28,2 GHz and 31-31,3 GHz. Yet, there are no specific regulations managing frequency allocation for HAP in Indonesia.

  5. Platform computing powers enterprise grid

    CERN Document Server

    2002-01-01

    Platform Computing, today announced that the Stanford Linear Accelerator Center is using Platform LSF 5, to carry out groundbreaking research into the origins of the universe. Platform LSF 5 will deliver the mammoth computing power that SLAC's Linear Accelerator needs to process the data associated with intense high-energy physics research (1 page).

  6. Contemporary Internet of Things platforms

    OpenAIRE

    Mineraud, Julien; Mazhelis, Oleksiy; Su, Xiang; Tarkoma, Sasu

    2015-01-01

    This document regroups a representative, but non-exhaustive, list of contemporary IoT platforms. The platforms are ordered alphabetically. The aim of this document is to provide the a quick review of current IoT platforms, as well as relevant information.

  7. Dependence of ideal MHD kink and ballooning modes on plasma shape and profiles in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Todd, A.M.M.; Manickam, J.; Okabayashi, M.; Chance, M.S.; Grimm, R.C.; Greene, J.M.; Johnson, J.L.

    1978-08-01

    Extensive numerical studies of ideal MHD instabilities have been carried out to gain insight into the parametric dependence of critical ..beta..'s in tokamaks. The large number of interrelated equilibrium quantities involved in establishing a critical ..beta.. has demanded a careful, systematic survey in order to isolate this dependence. The results of this survey establish the scaling with geometrical quantities including aspect ratio, elongation, and triangularity in the parameter regimes appropriate for both current and reactor-sized plasmas. A moderate dependence on the pressure profile and a strong variation with the current profile is found. The principal result is that for aspect ratio R/a approximately equal to 3, critical ..beta..'s are of the order of 2% for circular cross sections and 5% for plasmas with elongation K approximately equal to 2; somewhat higher values could be achieved with more optimal shaping. Finally, sequences of equilibria have been analyzed to compare critical ..beta.. as a function of toroidal mode number n. We conclude that the infinite-n analytic ballooning theory provides a sufficient condition for ideal MHD internal mode stability. Low-n free boundary modes appear to set a lower limit.

  8. Core stability and bicycling.

    Science.gov (United States)

    Asplund, Chad; Ross, Michael

    2010-01-01

    Bicycling is a popular fitness activity in the United States and around the world. Because of the nature of the bicycling position, the neck and back are at risk for injury. One method to prevent these injuries is to ensure that the body's "core" is strong and stable. A strong and stable core also provides a platform to maximize power transfer, improving performance. Core exercises also may enhance recovery from intense bicycling efforts. Simple stability exercises can improve performance and may prevent injuries in bicyclists.

  9. The use of a cutting balloon in contemporary reverse controlled antegrade and retrograde subintimal tracking (reverse CART) technique.

    Science.gov (United States)

    Nakabayashi, Keisuke; Okada, Hisayuki; Oka, Toshiaki

    2017-07-01

    The key concept of reverse controlled antegrade and retrograde tracking (CART) technique is retrograde puncture with a tapered wire to an antegrade balloon (contemporary reverse CART) or new connections between the antegrade and retrograde subintimal space (classical reverse CART). In our case, a 75-year-old man with severe chronic total occlusion of the right coronary artery, reverse CART with conventional balloons could not be accomplished. Externalization wiring was completed by contemporary reverse CART using a cutting balloon as an antegrade balloon to improve the fenestration force of the retrograde guidewire. Thus, the use of a cutting balloon for contemporary reverse CART might be promising.

  10. Stellarex Drug-Coated Balloon for Treatment of Femoropopliteal Disease

    Science.gov (United States)

    Faries, Peter; Niazi, Khusrow; Jain, Ash; Sachar, Ravish; Bachinsky, William B.; Cardenas, Joseph; Werner, Martin; Brodmann, Marianne; Mustapha, J. A.; Mena-Hurtado, Carlos; Jaff, Michael R.; Holden, Andrew H.; Lyden, Sean P.

    2017-01-01

    Background: Drug-coated balloons (DCBs) are a predominant revascularization therapy for symptomatic femoropopliteal artery disease. Because of the differences in excipients, paclitaxel dose, and coating morphologies, varying clinical outcomes have been observed with different DCBs. We report the results of 2 studies investigating the pharmacokinetic and clinical outcomes of a new DCB to treat femoropopliteal disease. Methods: In the ILLUMENATE Pivotal Study (Prospective, Randomized, Single-Blind, U.S. Multi-Center Study to Evaluate Treatment of Obstructive Superficial Femoral Artery or Popliteal Lesions With A Novel Paclitaxel-Coated Percutaneous Angioplasty Balloon), 300 symptomatic patients (Rutherford class 2–4) were randomly assigned to DCB (n=200) or standard angioplasty (percutaneous transluminal angioplasty [PTA]) (n=100). The primary safety end point was freedom from device- and procedure-related death through 30 days, and freedom from target limb major amputation and clinically driven target lesion revascularization through 12 months. The primary effectiveness end point was primary patency through 12 months. In the ILLUMENATE PK study (Pharmacokinetic Study of the Stellarex Drug-Coated Angioplasty Balloon), paclitaxel plasma concentrations were measured after last DCB deployment and at prespecified times (at 1, 4, 24 hours and at 7 and 14 days postprocedure) until no longer detectable. Results: In the ILLUMENATE Pivotal Study, baseline characteristics were similar between groups: 50% had diabetes mellitus, 41% were women, mean lesion length was 8.3 cm, and 44% were severely calcified. The primary safety end point was met (92.1% for DCB versus 83.2% for PTA, P=0.025 for superiority) and the primary patency rate was significantly higher with DCB (76.3% for DCB versus 57.6% for PTA, P=0.003). Primary patency per Kaplan-Meier estimates at day 365 was 82.3% for DCB versus 70.9% for PTA (P=0.002). The rate of clinically driven target lesion revascularization

  11. Platform deck. Plattformdekk

    Energy Technology Data Exchange (ETDEWEB)

    Gudmestad, O.T.; Warland, T.Aa.; Coker, J.W.A.; Stead, B.

    1992-03-30

    The invention deals with a platform deck comprising a trusswork deck section and a deck section made of plates designed for being welded together for the final concreting. The deck structure is designed for being connected to at least two shafts, and can include equipment, needing protection against pollution, or natural ventilation systems. Each of the two sections mentioned can be built by different contractors and finally assembled onshore or offshore. Both of the sections are equipped with corresponding upper and lower supporting elements for simplifying the assembling procedure. 4 figs.

  12. Central American and Caribbean Citizen Security Platform | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Violent crime rates threaten political and social stability, and trust in democracy, in Central American and Caribbean societies. ... The five priority public policy issues for the platform include: -crime prevention -enhancing security -access to justice -rehabilitation -reinsertion This project will identify critical and neglected areas ...

  13. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kumita, Shin-ichiro [Nippon Medical School, Department of Radiology, Center for Advanced Medical Technology, Tokyo (Japan); Kawamoto, Chiaki [Nippon Medical School, Department of Internal Medicine, Tokyo (Japan); Uchida, Eiji [Nippon Medical School, Department of Surgery, Tokyo (Japan)

    2017-06-15

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. (orig.)

  14. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Science.gov (United States)

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all pplacenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  15. A new approach to the diagnosis of esophageal rupture due to balloon dilatation

    International Nuclear Information System (INIS)

    Song, Ho Young; Han, Young Min; Lee, Sang Young; Kuh, Ja Hong; Lee, Dong Kun; Chae, Soo Wan

    1990-01-01

    The diagnosis of esophageal rupture in balloon dilatation is usually made from clinical symptom of sharp chest pain, plain chest radiographs and esophagograms after dilation. It has some problems; the pain is varied patients to patients and bacterial flora in the mouth or esophagus can be mixed with the contrast media to flow into the mediastinum during esophagography, to create mediastinitis. We could make the diagnosis of esophageal rupture without using contrast media by the observation of the pressure change in the balloon during dilatation. An infusion pump, transducer and esophageal balloon were connected through a multi-way connector, and the transducer of them was also connected to an amplifier which was connected to a pressure monitor to record the balloon pressure. As balloon(20mm/3cm) inserted in the mid-thoracic esophagus under the fluoroscopic control was inflated until the esophagus was ruptured. Balloon was distended by injecting air in 15 rabbits(A group), and by injecting diluted contrast medium in 15 rabbits(B group). The pressure decrease after esophageal rupture was ranged from 94 to 160 mmHg(mean; 103) in A group and 340 to 1040 mmHg(mean; 537) in B group. The pressure curve of A group was smooth, regular and so accurate to make the diagnosis of esophageal rupture, whereas that of B group was irregular and not so accurate. In conclusion, our new method to make the diagnosis of esophageal rupture during balloon dilatation may be useful in patients of esophageal stricture

  16. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Kjeldsen, Anette D.

    2008-01-01

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenous malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations

  17. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery

    International Nuclear Information System (INIS)

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kumita, Shin-ichiro; Kawamoto, Chiaki; Uchida, Eiji

    2017-01-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. (orig.)

  18. In-situ observation of irradiation quantities using a tethered balloon

    Science.gov (United States)

    Becker, Ralf; Gross, Steffen; Behrens, Klaus

    2014-05-01

    Irradiance is a key parameter in Earth's weather and climate system. Accurate observations of the components of the radiation budget are therefore essential to create reliable time series, to analyse spatial variability and to test, validate and adapt satellite-based algorithms. This holds true for near surface measurements as well as for in-situ observations in the lower troposphere. Such measurements are difficult to realise and therefore rarely performed. A tethered balloon system manufactured by Vailsala (9 cbm) is utilised as a carrier of a radiation budget sonde operating up to 1000 m above ground. Application is limited to fair weather conditions with maximum winds of 20 km/h and visibility greater than 3 km at ground level. The experimental setup is composed of a downward and upward looking pair of Kipp&Zonen CM11 (0.305-2.8 μm) and a corresponding pair of Kipp&Zonen CG4 (4.5 - 42 μm). Instruments are categorized as WMO 'secondary standard' according to ISO9660 and can be characterised as sufficiently robust and with acceptable response time for this purpose. Instrumentation is complemented by meteorological sensors (wind, temperature, humidity) flown on a dedicated suspension close (less than 50 m distance) to radiation sonde. In-situ measurements of irradiation in flowing and turbulent air are subjected to errors due to moving platform (roll/yaw/pitch). Potential deviations to near-surface measurements are discussed and an error estimate is given. Some comparisons of results of radiative transfer calculations for simple meteorological conditions have been made so far. It can be accomplished either by referring to profiles or by evaluating time series taken at elevated levels. Profiling lacks stationarity most time of a day due to high variability of shortwave downward and thus must be interpreted carefully. First results for longwave profiles as well as evaluation of time series obtained at distinct levels above ground show good correspondence.

  19. Tethered balloon measurements of biogenic volatile organic compounds at a Boreal forest site

    Directory of Open Access Journals (Sweden)

    C. Spirig

    2004-01-01

    Full Text Available Measurements of biogenic volatile organic compounds (VOCs were performed at Hyytiälä, a Boreal forest site in Southern Finland as part of the OSOA (origin and formation of secondary organic aerosol project in August 2001. At this site, frequent formation of new particles has been observed and the role of biogenic VOCs in this process is still unclear. Tethered balloons served as platforms to collect VOC samples within the planetary boundary layer at heights up to 1.2 km above ground during daytime. Mean mixed layer concentrations of total monoterpenes varied between 10 and 170 pptv, with a-pinene, limonene and D3-carene as major compounds, isoprene was detected at levels of 2-35 pptv. A mixed layer gradient technique and a budget approach are applied to derive surface fluxes representative for areas of tens to hundreds of square kilometres. Effects of spatial heterogeneity in surface emissions are examined with a footprint analysis. Depending on the source area considered, mean afternoon emissions of the sum of terpenes range between 180 and 300 mg m-2 h-1 for the period of 2-12 August 2001. Surface fluxes close to Hyytiälä were higher than the regional average, and agree well with mean emissions predicted by a biogenic VOC emission model. Total rates of monoterpene oxidation were calculated with a photochemical model. The rates did not correlate with the occurrence of new particle formation, but the ozone pathway was of more importance on days with particle formation. Condensable vapour production from the oxidation of monoterpenes throughout the mixed layer can only account for a fraction of the increase in aerosol mass observed at the surface.

  20. Static and quasi-static analysis of lobed-pumpkin balloon

    Science.gov (United States)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  1. Tether pointing platform and space elevator mechanisms analysis of the key concepts for SATP and scaled SATP

    Science.gov (United States)

    Turci, E.

    1986-01-01

    The key concepts for a scaled and full model Science and Applications Tethered Platform (SATP) are analysized. This includes a tether pointing platform and a space elevator. The mechanism concepts and technological solutions are given. The idea of the tether pointing platform mechanism is to control and stabilize the attitude of a platform by means of a movable tether. The idea of the space elevator mechanism for a scaled SATP is to drag the tether gripping it between two rotating wheels.

  2. The CERN Neutrino Platform

    CERN Document Server

    Bordoni, Stefania

    2018-01-01

    The long-baseline neutrino programme has been classified as one of the four highest-priority sci- entific objectives in 2013 by the European Strategy for Particle Physics. The Neutrino Platform is the CERN venture to foster and support the next generation of accelerator-based neutrino os- cillation experiments. Part of the present CERN Medium-Term Plan, the Neutrino Platform provide facilities to develop and prototype the next generation of neutrino detectors and contribute to unify the European neu- trino community towards the US and Japanese projects. A significative effort is made on R&D; for LAr TPC technologies: two big LAr TPC prototypes for the DUNE far detector are under con- struction at CERN. Those detectors will be exposed in 2018 to an entirely new and NP-dedicated beam-line from the SPS which will provide electron, muon and hadron beams with energies in the range of sub-GeV to a few GeV. Other projects are also presently under development: one can cite the refurbishing and shipping to the US ...

  3. Platform for Action: update.

    Science.gov (United States)

    1995-01-01

    The Center for Women's Global Leadership (CWGL) has collaborated in the preparation of amendments and strategies designed to withstand the challenges being posed to the Platform for Action of the Fourth World Conference on Women. Specific challenges include the inappropriate use of the word "universal" to modify "human rights." This implies that some human rights are less than universal. The strategy proposed is to accept the use of the word "universal" in this context only when it affirms principles of universality contained in the Vienna Programme of Action and not where its use would restrict the rights to which women are entitled. A second concern is over the use of the word "equity" rather than "equality" when referring to gender relations. The use of these terms will be carefully monitored to insure that "equity" not be used to undermine the principle of gender equality. The third concern is the efforts of some governments to hinder the integration of women's human rights throughout the UN system. Such efforts will be opposed. Fourth, the CWGL will seek the inclusion of language which recognizes the barriers that different groups of women face when trying to secure their rights. Finally, the CWGL will propose inclusion of language recognizing and protecting sexual orientation rights. The CWGL is also going to work to translate the abstract language of the Platform for Action into political organizing potential to insure that governments will follow through on their agreements.

  4. Initial Results from the ANITA 2006-2007 Balloon Flight

    Energy Technology Data Exchange (ETDEWEB)

    Gorham, P.W.; /Hawaii U.; Allison, P.; /Hawaii U.; Barwick, S.W.; /UC, Irvine; Beatty, J.J.; /Ohio State U.; Besson, D.Z.; /Kansas U.; Binns, W.R.; /Washington U., St. Louis; Chen, C.; /SLAC; Chen, P.; /SLAC; Clem, J.M.; /Delaware U.; Connolly, A.; /University Coll. London; Dowkontt, P.F.; /Washington U., St. Louis; DuVernois, M.A.; /Minnesota U.; Field, R.C.; /SLAC; Goldstein, D.; /UC, Irvine; Goodhue, A.; /UCLA; Hast, C.; /SLAC; Hebert, C.L.; /Hawaii U.; Hoover, S.; /UCLA; Israel, M.H.; /Washington U., St. Louis; Kowalski, J.; /Hawaii U.; Learned, J.G.; /Hawaii U. /Caltech, JPL /Hawaii U. /Minnesota U. /Hawaii U. /Ohio State U. /Hawaii U. /Hawaii U. /UC, Irvine /Taiwan, Natl. Taiwan U. /Caltech, JPL /SLAC /University Coll. London /Ohio State U. /SLAC /Hawaii U. /Hawaii U. /Hawaii U. /UCLA /Delaware U. /Hawaii U. /SLAC /Taiwan, Natl. Taiwan U. /UC, Irvine

    2011-11-16

    We report initial results of the Antarctic Impulsive Transient Antenna (ANITA) 2006-2007 Long Duration Balloon flight, which searched for evidence of the flux of cosmogenic neutrinos. ANITA flew for 35 days looking for radio impulses that might be due to the Askaryan effect in neutrino-induced electromagnetic showers within the Antarctic ice sheets. In our initial high-threshold robust analysis, no neutrino candidates are seen, with no physics background. In a non-signal horizontal-polarization channel, we do detect 6 events consistent with radio impulses from extensive air showers, which helps to validate the effectiveness of our method. Upper limits derived from our analysis now begin to eliminate the highest cosmogenic neutrino models.

  5. Audit of radiation dose during balloon mitral valvuloplasty procedure

    International Nuclear Information System (INIS)

    Livingstone, Roshan S; Chandy, Sunil; Peace, B S Timothy; George, Paul; John, Bobby; Pati, Purendra

    2006-01-01

    Radiation doses to patients during cardiological procedures are of concern in the present day scenario. This study was intended to audit the radiation dose imparted to patients during the balloon mitral valvuloplasty (BMV) procedure. Thirty seven patients who underwent the BMV procedure performed using two dedicated cardiovascular machines were included in the study. The radiation doses imparted to patients were measured using a dose area product (DAP) meter. The mean DAP value for patients who underwent the BMV procedure from one machine was 19.16 Gy cm 2 and from the other was 21.19 Gy cm 2 . Optimisation of exposure parameters and radiation doses was possible for one machine with the use of appropriate copper filters and optimised exposure parameters, and the mean DAP value after optimisation was 9.36 Gy cm 2

  6. Ballooning of pressure tubes - Construction of a test facility

    International Nuclear Information System (INIS)

    Forrest, C.F.

    1995-09-01

    The test facility has been built to enable creep testing of reactor pressure tube specimens under conditions which represent those likely to be encountered in a reactor loss-of-coolant accident. The facility has been designed to be capable of specimen heating rates up to 30 K.s -1 , temperatures up to 1200 C and internal pressurization up to 6 MPa with either argon or steam. Pressure tube temperature, strain rate, and pressure instrumentation have been provided for collection of data required for analysis of creep behaviour. The facility has been designed to be suitable for testing irradiated specimens in a hot cell. The report provides a detailed description of the test rig and results from two commissioning ballooning tests. (author). 2 refs., 1 tab., 4 figs

  7. Multimedia Capable Distributed Object Platform | Baichoo ...

    African Journals Online (AJOL)

    Multimedia Capable Distributed Object Platform. ... This paper discusses the design and implementation of a multimediacapable distributed object platform, using a low-level platform GOPI (General Object Platform ... Keywords: Multimedia; GOPI; IDL; CORBA; Quality of Service; Middleware; Distributed Systems.

  8. [Coronary angioplasty: efficacy of the new low profile balloon catheters].

    Science.gov (United States)

    Feres, F; Tanajura, L F; Pinto, I M; Cano, M N; Maldonado, G; Mattos, L A; de Araújo, E C; Sousa, A G; Sousa, J E

    1989-12-01

    New low profile balloon catheter have allowed the indication of percutaneous transluminal coronary angioplasty (PTCA) for more complex lesions. We report our initial experience with these systems in 50 out of 101 patients (50%) who underwent a PTCA from March 15 to May 15, 1989 in "Instituto Dante Pazzanese de Cardiologia". Mean age was 58.6 +/- 10.4 years and most of the patients were male (78%). We dilated 54 lesions. Single vessel disease was the case for 84% of the patients. As for the localization of the lesions in the coronary arteries, 56% of the lesions were in the proximal or mid segments of the coronary arteries and the mean diameter stenosis pre-PTCA was 84 +/- 10.2%. Left ventricular function was normal in 60% of the patients. Primary success rate (per patient) was 95% and the coronary stenosis was crossed in all the cases. The mean inflation number was 2.7 +/- 0.6 per patient, the mean highest pressure was 8 +/- 1.15 atm and the mean maximum time of inflation was 86.1 +/- 29.6 sec. The mean residual stenosis was 15.2 +/- 10.6%. There was only one major complication, namely an acute myocardial infarction of the lateral wall. There were no emergency CABG surgery or deaths. We conclude that the new low profile balloon catheters have broadened the indication for PTCA in more complicated lesions, showing a high rate of primary success (95%), but did not increase the number of procedural complications (2.5%).

  9. Primary balloon angioplasty for symptomatic, high-grade intracranial stenosis.

    Science.gov (United States)

    Tomycz, Luke; Bansal, Neil K; Lockney, Tim; Strothers, Megan; Connors, John J; Shay, Scott; Singer, Robert J

    2013-01-01

    In light of recent controversy about the safety and efficacy of intracranial stenting, we sought to evaluate our experience with primary balloon angioplasty for symptomatic, high-grade intracranial stenosis. All intracranial angioplasty cases performed at Vanderbilt University Medical Center from 2006 to 2011 were retrospectively reviewed for degree of stenosis pre- and post-procedure. Immediate peri-procedural complications were evaluated as well as one-month and long-term outcomes. A total of 26 patients were included in the study with a mean age of 63.0 years and a mean follow-up of 350.2 days. The average pre-procedure stenosis was 71.2%. The immediate, average post-procedure stenosis was 46.6%, and the average post-procedure stenosis at last angiographic follow-up was 44.5%. Retreatment was required in only 3.8% of patients. The primary end-point of major stroke or death at 30 days was observed in 11.5%, and the overall intra-procedural complication rate was 7.7%. The incidence of stroke or death at last follow-up was 15.4%, which is comparable to the one-year stroke or death rate in the medical arm of the SAMPRISS trial. In this retrospective series, primary balloon angioplasty was found to be effective as a treatment option for symptomatic intracranial stenosis with the risk of stroke or death at 30 days higher than the medical arm of SAMPRIS but lower than the stenting arm. The one-year risk of stroke was comparable to that reported for the one-year outcomes in the SAMPRISS medical arm.

  10. Drug-eluting balloons for treatment of SFA and popliteal disease - A review of current status.

    Science.gov (United States)

    van den Berg, Jos C

    2017-06-01

    The endovascular treatment of atherosclerotic disease of the infra-inguinal arteries has changed significantly over the last decades. In an attempt to overcome the high restenosis rates that characterize plain balloon angioplasty and stenting using bare mate stents drug-eluting balloon technology has been applied in the treatment of lesions of the superficial femoral and popliteal artery. This paper will give an overview of the rationale and the technology of drug-eluting balloons and will review currently available data from registries and randomized controlled trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Intragastric balloon treatment of obesity must be combined with bariatric surgery: a pilot study in Turkey.

    Science.gov (United States)

    Saruç, Murat; Böler, Deniz; Karaarslan, Mehmet; Baysal, Çağlar; Rasa, Kemal; Çakmakçi, Metin; Uras, Cihan; Tözün, Nurdan

    2010-12-01

    The treatment of morbid obesity by intragastric balloon (BioEnterics) placement is a safe and effective procedure. Cultural, social and economical factors are known to have an impact on the outcome of therapeutic interventions. This study aimed to evaluate the effect of this method on weight loss and long-term outcome following balloon removal in a cohort of Turkish patients. Twenty-five patients (11 male, 14 female) who selected BioEnterics intragastric balloon method for weight loss over surgery were included in the study. Their mean age was 35.2±13.4 and mean body mass index was 43.5±8.7 kg/m2. Patients who had any contraindication for endoscopic BioEnterics intragastric balloon placement were excluded. BioEnterics intragastric balloon was performed under deep sedation with propofol, and all patients were placed on a 1000 kcal/day diet for six months. Patients were reevaluated six months following balloon removal. Excess weight loss of greater than 25% was considered as end of treatment success. Maintenance of excess weight loss greater than 25% at the end of a six-month follow-up period was considered as long-term success. Results were reported as mean body mass index and mean %excess weight loss±SD. Statistical analysis was done using SPSS computer program. One patient was excluded from the study because of psychological intolerance (1/25) prompting early balloon removal. Twenty-four patients completed both the initial phase and the follow-up period. At the end of the initial six months, the mean body mass index was 35.7±4.6 kg/m2 and mean excess weight loss was 46.9±11.3%. Although 22 out of 24 patients (91.6%) had achieved end of treatment success, the mean body mass index was back to 41.9±7.7 kg/m2 at the end of the follow-up period. Only two patients were able to maintain excess weight loss of 25% at the completion of the study, resulting in a long-term success rate of 8.3%. BioEnterics intragastric balloon is a safe and effective but temporary

  12. The therapy of esophageal stricture caused by erosive through balloon dilation

    International Nuclear Information System (INIS)

    Li Yi; Zeng Xianqiang; Wang Rongqin; Ding Xiaolin; You Guoqing; Shao Hede; Zhang Xinyuan

    2004-01-01

    Objective: To evaluate the therapy of esophageal stricture caused by erosive burn of esophagus through balloon dilation. Methods: 9 patients of esophageal stricture caused by erosive burn of esophagus have been treated by balloon dilation. Results: 9 patients have been dilated 26 times altogether 7 of them can eat normally. 2 patients' symptoms were improved. Six months to two years after operation, the symptoms were not reoccurred. All of them have no serious complications. Conclusion: Balloon dilation is one of the effective and safe therapy of esophageal stricture caused by erosive burn. (authors)

  13. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Kjeldsen, Anette D

    2008-01-01

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months...... anymore, but use of these balloons for embolization of pulmonary arteriovenous malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing...

  14. SBARMO-79 a multi-balloon campaign in the auroral zone

    International Nuclear Information System (INIS)

    Tanskanen, P.; Kangas, J.; Bjordal, J.; Bronstad, K.; Block, L.P.; Holtet, T.

    1982-01-01

    A joint European International Magnetospheric Study (IMS) balloon campaign was conducted within the framework of the Scientific Ballooning and Radiation Monitoring Organization (SBARMO). The campaign was carried out during the time from May 30 to July 10, 1979. A total of 29 successful balloon launches were made from four launch sites located in Norway and in Finland. The campaign has the objective to provide information for a better understanding of temporal and spatial variations of magnetospheric processes, giving particular attention to the coupling between the magnetosphere and the ionosphere

  15. Platform Performance and Challenges - using Platforms in Lego Company

    DEFF Research Database (Denmark)

    Munk, Lone; Mortensen, Niels Henrik

    2009-01-01

    This article studies the performance and challenges of using nine implemented product platforms in LEGO Company. Most of these do produce results, but do not meet their goals due to challenges in their usage in the daily product. The main challenges are that the platforms are not being used...... needs focus on the incentive of using the platform. This problem lacks attention in literature, as well as industry, where assessment criteria do not cover this aspect. Therefore, we recommend including user incentive in platform assessment criteria to these challenges. Concrete solution elements...

  16. First-in-human experience using the Volcano VIBE-RX vascular imaging balloon catheter system (Volcano IVUS-guided Balloon Evaluation - New Zealand: VIBE-NZ Study).

    Science.gov (United States)

    Watson, Timothy; El-Jack, Seifeddin; Stewart, James T; Ormiston, John

    2013-09-01

    Intravascular ultrasound (IVUS) is a proven and safe imaging modality used to guide percutaneous coronary intervention (PCI). The Volcano VIBE™ RX Vascular Imaging Balloon Catheter is a novel rapid exchange, 0.014" wire-compatible multi-lumen conventional balloon catheter modified with the addition of an IVUS transducer proximal to the balloon, delivered via a standard 6 Fr sheath. We sought to evaluate the safety, balloon performance, and image quality of the VIBE™ RX in patients scheduled for coronary intervention. Patients aged >21 and <85 years with single or multivessel coronary disease scheduled for PCI due to coronary ischaemic symptoms were included. Those with angiographic features that precluded the safe or informative use of the device were excluded. Twenty-nine patients having angiography because of ischaemic symptoms underwent 44 VIBE RX imaging runs, with balloon dilation in 20. Successful device deployment was achieved in all but one patient. All images were adequate and reproducible. One patient had a non-ST-elevation MI felt to be due to the complexity of the procedure rather than directly related to the VIBE™ RX. The study demonstrated the safety and effectiveness of the VIBE™ RX for its intended purpose with minimal failure rate and no directly related complications.

  17. The Dynamics of Digital Platform Innovation

    DEFF Research Database (Denmark)

    Eaton, Ben

    2016-01-01

    Curated platforms provide an architectural basis for third parties to develop platform complements and for platform owners to control their implementation as a form of open innovation. The refusal to implement complements as innovations can cause tension between platform owners and developers. Th...... digital platforms. In doing so, it uses IS notions of digitalization to challenge traditional understandings of innovation in platform architectures....

  18. Percutaneous balloon pulmonary valvuloplasty: A modified over-the-wire Inoue balloon technique for difficult right ventricular anatomy

    Directory of Open Access Journals (Sweden)

    Surender Deora

    2014-03-01

    Full Text Available Percutaneous balloon pulmonary valvuloplasty (BPV is the mainstay of treatment for significant pulmonary stenosis with doming leaflets. Various techniques have been described in the literature including the use of Inoue Percutaneous Transseptal Mitral Commissurotomy (PTMC catheter with standard 0.025″ guidewire. But if right ventricular anatomy is not suitable, 0.025″ guidewire doesn't provide enough support to track the Inoue PTMC catheter. Here, we report a case of successful BPV using a novel technique of slenderizing the Inoue Percutaneous Transseptal Mitral Commissurotomy (PTMC catheter over an Amplatz superstiff 0.035″ guidewire. This technique may be useful during BPV in difficult right ventricular inflow and outflow tract anatomy in patients with congenital pulmonary valve stenosis.

  19. Adoption of Mobile Payment Platforms

    DEFF Research Database (Denmark)

    Staykova, Kalina Stefanova; Damsgaard, Jan

    2016-01-01

    Numerous mobile payment solutions, which rely on new disruptive technologies, have been launched on the payment market in recent years. But despite the growing number of mobile payment apps, very few solutions have turned to be successful as the majority of them fail to gain a critical mass...... of users. In this paper, we investigate successful platform adoption strategies by using the Reach and Range Framework for Multi-Sided Platforms as a strategic tool to which mobile payment providers can adhere in order to tackle some of the main challenges they face throughout the evolution...... of their platforms. The analysis indicates that successful mobile payment solutions tend to be launched as one-sided platforms and then gradually be expanded into being two-sided. Our study showcases that the success of mobile payment platforms lies with the ability of the platform to balance the reach (number...

  20. Energy Tracking Software Platform

    Energy Technology Data Exchange (ETDEWEB)

    Ryan Davis; Nathan Bird; Rebecca Birx; Hal Knowles

    2011-04-04

    Acceleration has created an interactive energy tracking and visualization platform that supports decreasing electric, water, and gas usage. Homeowners have access to tools that allow them to gauge their use and track progress toward a smaller energy footprint. Real estate agents have access to consumption data, allowing for sharing a comparison with potential home buyers. Home builders have the opportunity to compare their neighborhood's energy efficiency with competitors. Home energy raters have a tool for gauging the progress of their clients after efficiency changes. And, social groups are able to help encourage members to reduce their energy bills and help their environment. EnergyIT.com is the business umbrella for all energy tracking solutions and is designed to provide information about our energy tracking software and promote sales. CompareAndConserve.com (Gainesville-Green.com) helps homeowners conserve energy through education and competition. ToolsForTenants.com helps renters factor energy usage into their housing decisions.

  1. Web Platform Application

    Energy Technology Data Exchange (ETDEWEB)

    Paulsworth, Ashley [Sunvestment Group, Frederick, MD (United States); Kurtz, Jim [Sunvestment Group, Frederick, MD (United States); Brun de Pontet, Stephanie [Sunvestment Group, Frederick, MD (United States)

    2016-06-15

    Sunvestment Energy Group (previously called Sunvestment Group) was established to create a web application that brings together site hosts, those who will obtain the energy from the solar array, with project developers and funders, including affinity investors. Sunvestment Energy Group (SEG) uses a community-based model that engages with investors who have some affinity with the site host organization. In addition to a financial return, these investors receive non-financial value from their investments and are therefore willing to offer lower cost capital. This enables the site host to enjoy more savings from solar through these less expensive Community Power Purchase Agreements (CPPAs). The purpose of this award was to develop an online platform to bring site hosts and investors together virtually.

  2. Stability of Finite-n Global Magnetohydrodynamic Modes Using the GATO Stability Code

    Science.gov (United States)

    Chu, M. S.; Wong, S. K.; Lao, L. L.; Turnbull, A. D.; Chance, M. S.

    1999-11-01

    This work extends the capability of the GATO stability code(L.C.Bernard et al.), Comput. Phys. Commun. 24, 377 (1981). to analyze realistic numerical tokamak equilibria for their stability to higher n ( ~5--10) MHD modes. This is motivated by the experimental evidence of these modes being relevant for both plasma termination and the behavior of ELMs. The ballooning angle transformation(R. Gruber et al.), Comput. Phys. Commun. 24, 363 (1981). is applied to the displacement variables in the GATO representation. The potential energy matrix is constructed with the inclusion of extra mapping quantities. The vacuum energy computed from the Green's function is also modified to couple to the transformed displacement at the plasma boundary. The resultant eigenvalue problem is solved with the modified boundary condition in the poloidal direction suitable for these transformed variables. The dependence of the plasma stability as a function of toroidal mode number and plasma equilibrium properties will be presented.

  3. Printable Spacecraft: Flexible Electronic Platforms for NASA Missions. Phase One

    Science.gov (United States)

    Short, Kendra (Principal Investigator); Van Buren, David (Principal Investigator)

    2012-01-01

    Atmospheric confetti. Inchworm crawlers. Blankets of ground penetrating radar. These are some of the unique mission concepts which could be enabled by a printable spacecraft. Printed electronics technology offers enormous potential to transform the way NASA builds spacecraft. A printed spacecraft's low mass, volume and cost offer dramatic potential impacts to many missions. Network missions could increase from a few discrete measurements to tens of thousands of platforms improving areal density and system reliability. Printed platforms could be added to any prime mission as a low-cost, minimum resource secondary payload to augment the science return. For a small fraction of the mass and cost of a traditional lander, a Europa flagship mission might carry experimental printed surface platforms. An Enceladus Explorer could carry feather-light printed platforms to release into volcanic plumes to measure composition and impact energies. The ability to print circuits directly onto a variety of surfaces, opens the possibility of multi-functional structures and membranes such as "smart" solar sails and balloons. The inherent flexibility of a printed platform allows for in-situ re-configurability for aerodynamic control or mobility. Engineering telemetry of wheel/soil interactions are possible with a conformal printed sensor tape fit around a rover wheel. Environmental time history within a sample return canister could be recorded with a printed sensor array that fits flush to the interior of the canister. Phase One of the NIAC task entitled "Printable Spacecraft" investigated the viability of printed electronics technologies for creating multi-functional spacecraft platforms. Mission concepts and architectures that could be enhanced or enabled with this technology were explored. This final report captures the results and conclusions of the Phase One study. First, the report presents the approach taken in conducting the study and a mapping of results against the proposed

  4. Product Platform Screening at LEGO

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik; Steen Jensen, Thomas; Nielsen, Ole Fiil

    2012-01-01

    Product platforms offer great benefits to companies developing new products in highly competitive markets. Literature describes how a single platform can be designed from a technical point of view, but rarely mentions how the process begins. How do companies identify possible platform candidates......, and how do they assess if these candidates have enough potential to be worth implementing? Danish toy manufacturer LEGO has systematically gone through this process twice. The first time the results were poor; almost all platform candidates failed. The second time, though, has been largely successful...

  5. Balloon-Borne Electric-Field Observations Relevant to Models for Sprites and Jets

    National Research Council Canada - National Science Library

    Beasley, William

    1999-01-01

    We designed and built a new balloon-borne electric-field-change instrument and launched five of them into thunderstorms to observe changes in the vertical component of electric field caused by lightning...

  6. Novel Ultralow-Weight Metal Rubber Sensor System for Ultra Long-Duration Scientific Balloons Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NanoSonic proposes to develop an innovative, ultralow mass density, and non-intrusive sensor system for ultra long duration balloons that will operate in the most...

  7. The Balloon Experimental Twin Telescope for Infrared Interferometry : Returning to Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter far-infrared (30-90 micron) Michelson interferometer, designed to fly on a...

  8. Sub-Scale Re-entry Capsule Drop via High Altitude Balloons

    Data.gov (United States)

    National Aeronautics and Space Administration — The project objective is to develop and test a sub-scale version of the Maraia Entry Capsule on a high altitude balloon. The capsule is released at 100,000 ft. The...

  9. The prevention and management of complications during and immediately after percutaneous balloon mitral valvuloplasty

    International Nuclear Information System (INIS)

    Jiang Shiliang; Huang Lianjun; Xu Zhongying; Zhao Shihua; Zheng Hong; Ling Jian; Xie Ruolan; Dai Ruping

    2002-01-01

    Objective: To approach the cause and treatment of complication during and immediately after percutaneous balloon mitral valvuloplasty. Methods: One thousand three hundred and eleven patients with mitral stenosis were treated by percutaneous transseptal balloon mitral valvuloplasty. Among them, 42 patients with complications were retrospectively analyzed. Results: The overall complications rate was 3.2% (42/1311) including atrial fibrillation 0.8% (10/1311), acute pericardial tamponade 0.31% (4/1311), severe mitral insufficiency 0.46% (6/1311), femoral arterial venous fistula 0.69% (9/1311), acute pulmonary edema and iatrogenic atrial septal defect 0.23% (3/1311), respectively. Coronary air embolism, arterial thrombosis and transient cerebrovascular accident was 0.15% (2/1311) for every other one. Balloon rupture was 0.08%(1/1311). Conclusions: The complications of percutaneous balloon mitral valvuloplasty rarely occur. It is a safe and efficient nonsurgical method for treating rheumatic mitral stenosis

  10. Induced Radioactivity Measured in a Germanium Detector After a Long Duration Balloon Flight

    Science.gov (United States)

    Starr, R.; Evans, L. G.; Floyed, S. R.; Drake, D. M.; Feldman, W. C.; Squyres, S. W.; Rester, A. C.

    1997-01-01

    A 13-day long duration balloon flight carrying a germanium detector was flown from Williams Field, Antartica in December 1992. After recovery of the payload the activity induced in the detector was measured.

  11. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; de Groot, Gerrit H.

    2013-01-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients

  12. Double balloon esophageal catheter for diagnosis of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Kiyan, Guersu; Dagli, Tolga E.; Tugtepe, Halil; Kodalli, Nihat

    2003-01-01

    Congenital H-type and recurrent tracheo-esophageal fistulas (TEF) are always difficult to diagnose. For a more accurate diagnosis we designed a new double balloon catheter, which is a modification of esophageal dilatation balloon. The catheter has two balloons to occlude the esophagus proximal and distal to the fistula. The fistula can be identified by passing of the contrast material to the tracheal tree, which was injected into the esophageal segment between the inflated balloons. To prove the efficiency of this catheter, a TEF was created surgically in a New Zealand rabbit. On the postoperative fourteenth day the catheter was tried and the fistula could be visualized easily by injecting the contrast material. We think this technique may be of use in the diagnosis of TEF in children. (orig.)

  13. Clinics in diagnostic imaging (165). Oesophageal rupture secondary to malposition of an SB tube gastric balloon.

    Science.gov (United States)

    Chan, Wan Ying; Cheong, Hsueh Wen; Tan, Tien Jin

    2016-02-01

    Oesophageal rupture is a life-threatening complication of balloon tamponade for bleeding oesophageal varices. We herein describe the clinical course and imaging findings in a 33-year-old Indian man who had a Sengstaken-Blakemore (SB) tube inserted for uncontrolled haematemesis, which was unfortunately complicated by malposition of the gastric balloon with resultant oesophageal rupture. The inflated SB tube gastric balloon was visualised within the right hemithorax on chest radiography after the SB tube insertion. Further evaluation of the thorax on computed tomography confirmed the diagnosis of oesophageal rupture associated with right-sided haemopneumothorax. It is crucial for both the referring clinician and reporting radiologist to recognise early the imaging features of an incorrectly positioned SB tube gastric balloon, so as to ensure prompt intervention and a reduction in patient morbidity and mortality. Copyright © Singapore Medical Association.

  14. Balloon occlusion of the internal iliac arteries in the multidisciplinary management of placenta percreta

    DEFF Research Database (Denmark)

    Clausen, Caroline; Stensballe, Jakob; Albrechtsen, Charlotte K

    2013-01-01

    Objective. To evaluate our experience with prophylactic balloon occlusion of the internal iliac arteries as a part of a multidisciplinary algorithm for the management of placenta percreta. Design. Consecutive case series. Setting. Rigshospitalet, Copenhagen University Hospital, Denmark. Sample. S...

  15. Transcatheter pulmonary valve perforation and balloon dilatation in neonates with pulmonary atresia and intact ventricular septum

    NARCIS (Netherlands)

    Gerestein, C.G.; Berger, R.M.F.; Dalinghaus, M.; Bogers, A.J.J.C.; Witsenburg, M.

    2003-01-01

    BACKGROUND: Pulmonary atresia and intact ventricular septum is characterised by a great morphological variety. Treatment is not uniform. OBJECTIVE: To evaluate our experience with transcatheter valvotomy and balloon dilatation in neonates with pulmonary atresia and intact ventricular septum. DESIGN:

  16. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    Science.gov (United States)

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Demonstrating Classical Conditioning in Introductory Psychology: Needles Do Not Always Make Balloons Pop!

    Science.gov (United States)

    Vernoy, Mark W.

    1987-01-01

    Describes a method of teaching classical conditioning to an introductory psychology class which involves demonstrating the conditioned response that occurs when a needle pierces, but does not pop, a balloon. (GEA)

  18. Endoscopic balloon dilatation for Crohn's strictures of the gastrointestinal tract is feasible

    DEFF Research Database (Denmark)

    Karstensen, John Gásdal; Hendel, Jakob; Vilmann, Peter

    2012-01-01

    Despite optimized medical treatment, Crohn´s disease can cause gastrointestinal (GI) strictures, which requires surgical intervention. Lately, endoscopic balloon dilatation has been established as an alternative to surgery. In the following, we report our experiences with endoscopic dilatation...

  19. ERCP with the Balloon-Assisted Enteroscopy Technique : A Systematic Review

    NARCIS (Netherlands)

    Koornstra, Jan J.; Fry, Lucia; Moenkemueller, Klaus

    2008-01-01

    Background: Endoscopic retrograde cholangiopancreatography (ERCP) is generally difficult with conventional instruments in patients with surgically altered gastrointestinal anatomy. Balloon-assisted enteroscopy is a relatively new technique that allows for access to the papilla of Vater or a

  20. Thermal balloon endometrial ablation: safety aspects evaluated by serosal temperature, light microscopy and electron microscopy

    DEFF Research Database (Denmark)

    Andersen, L F; Meinert, L; Rygaard, Carsten

    1998-01-01

    OBJECTIVES: Thermal balloon endometrial ablation is a new method for treating menorrhagia. The technique appears to be less difficult compared to standard hysteroscopic ablation techniques and to be significantly safer. The influence into the uterine wall of the thermal balloon ablation procedure...... was investigated with special reference to the ability of total destruction of the endometrium and the thermal action on the myometrium and the serosa. STUDY DESIGN: Temperatures were measured at the uterine serosal surface during thermal balloon endometrial ablation for 8-16 min in eight patients. After...... in all patients, with a maximum depth of 11.5 mm. By electron microscopy no influence of heat could be demonstrated beyond 15 mm from the endometrial surface. CONCLUSION: Up to 16 min of thermal balloon endometrial ablation therapy can destroy the endometrium and the submucosal layers. The myometrium...

  1. Deflation of the ′obstinate′ Foley′s urinary catheter balloon : a new technique.

    Directory of Open Access Journals (Sweden)

    Ramakantan R

    1989-01-01

    Full Text Available We have successfully deflated "obstinate" Foley′s urinary catheter balloons in 15 cases in the last six months with the help of a simple bedside procedure using an angiographic guide-wire.

  2. Low Cost Variable Conductance Heat Pipe for Balloon Payload, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — While continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to...

  3. Private Pilot Practical Test Standards for Lighter-Than-Air Balloon, Airship

    Science.gov (United States)

    1996-06-01

    The Private Pilot - Lighter-Than-Air (Balloon and Airship) Practical Test Standards (PTS) book has been published by the Federal Aviation Administration (FAA) to establish the standards for private pilot certification practical tests for the lighter-...

  4. Predictors for outcome of failure of balloon dilatation in patients with achalasia

    NARCIS (Netherlands)

    J. Alderliesten (Joyce); J.M. Conchillo; I. Leeuwenburgh (Ivonne); E.W. Steyerberg (Ewout); E.J. Kuipers (Ernst)

    2011-01-01

    textabstractBackground: Pneumatic balloon dilatation (PD) is a regular treatment modality for achalasia. The reported success rates of PD vary. Recurrent symptoms often require repeated PD or surgery. Objective: To identify predicting factors for symptom recurrence requiring repeated treatment.

  5. Publishing Platform for Scientific Software - Lessons Learned

    Science.gov (United States)

    Hammitzsch, Martin; Fritzsch, Bernadette; Reusser, Dominik; Brembs, Björn; Deinzer, Gernot; Loewe, Peter; Fenner, Martin; van Edig, Xenia; Bertelmann, Roland; Pampel, Heinz; Klump, Jens; Wächter, Joachim

    2015-04-01

    the life sciences. Based on the developed blueprints a scientific software publishing platform will be iteratively implemented, tested, and evaluated. Thus the platform should be developed continuously on the basis of gained experiences and results. The platform services will be extended one by one corresponding to the requirements of the communities. Thus the implemented platform for the publication of scientific software can be improved and stabilized incrementally as a tool with software, science, publishing, and user oriented features.

  6. Introducing Platform Interactions Model for Studying Multi-Sided Platforms

    DEFF Research Database (Denmark)

    Staykova, Kalina; Damsgaard, Jan

    2018-01-01

    Multi-Sided Platforms (MSPs) function as socio-technical entities that facilitate direct interactions between various affiliated to them constituencies through developing and managing IT architecture. In this paper, we aim to explain the nature of the platform interactions as key characteristic o...

  7. Intracervical Foley balloon catheter for cervical ripening and labor induction: A review.

    Science.gov (United States)

    Greenberg, Victoria; Khalifeh, Adeeb

    2015-10-01

    Labor induction is a common obstetric practice. Optimal methods of both ripening and induction are debated. This article assesses the intracervical Foley balloon catheter through review of literature, including meta-analyses, randomized controlled trials, and retrospective data. Discussion includes comparison of Foley balloon catheters to pharmacologic agents, safety profile in various clinical scenarios, and cost-effectiveness. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Environmental effects of the US Antarctic Program`s use of balloons in Antarctica

    Energy Technology Data Exchange (ETDEWEB)

    McCold, L.N.; Eddlemon, G.K.; Blasing, T.J.

    1995-06-01

    The USAP uses balloons in Antarctica to conduct scientific research, to facilitate safe air transport, and to provide data for global weather predictions. However, there is the possibility that balloons or their payloads may adversely affect Antarctic fauna or flora. The purpose of this study is to provide background information upon which the USAP may draw when complying with its responsibilities under the National Environmental Policy Act of 1969, the Antarctic Treaty, and the Madrid Protocol.

  9. Design of experiments and equipment to test the ballooning characteristics of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Forrest, C.F.; Stern, F.; Hart, R.G.

    1992-01-01

    Experiments have been planned and an apparatus has been designed to enable creep testing of end-of-life pressure tube specimens in a LOCA environment. Effects that could be studied include: annealing of irradiation damage during transient heating; effects of hydride blisters on pressure tube ballooning strains; and, effects of uniformly-distributed hydrogen content on pressure tube ballooning strains. The proposed experimental program will consist of separate effects creep tests on pressure tube sections under transient heating conditions

  10. Potential of balloon payloads for in flight validation of direct and nulling interferometry concepts

    Science.gov (United States)

    Demangeon, Olivier; Ollivier, Marc; Le Duigou, Jean-Michel; Cassaing, Frédéric; Coudé du Foresto, Vincent; Mourard, Denis; Kern, Pierre; Lam Trong, Tien; Evrard, Jean; Absil, Olivier; Defrere, Denis; Lopez, Bruno

    2010-07-01

    While the question of low cost / low science precursors is raised to validate the concepts of direct and nulling interferometry space missions, balloon payloads offer a real opportunity thanks to their relatively low cost and reduced development plan. Taking into account the flight capabilities of various balloon types, we propose in this paper, several concepts of payloads associated to their flight plan. We also discuss the pros and cons of each concepts in terms of technological and science demonstration power.

  11. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    Science.gov (United States)

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  12. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    Science.gov (United States)

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  13. [The Application of Internal Iliac Artery Balloon Occlusion in Pernicious Placenta Previa].

    Science.gov (United States)

    Qi, Xiao-Rong; Liu, Xing-Hui; You, Yong; Wang, Xiao-Dong; Zhou, Rong; Xing, Ai-Yun; Zhang, Li; Ning, Gang; Zhao, Fu-Min; Li, Kai-Ming

    2016-07-01

    To evaluate the clinical application value of internal iliac artery balloon occlusion in pernicious placenta previa. We retrospectively reviewed the medical records of the patients of pernicious placenta previa in a single center from Jan, 2010 to Jan, 2015. The patients were divided into two groups, internal iliac artery balloon occlusion group and the control group without endovascular intervention. Blood loss in operation, volume of transfused blood products, caesarean hysterectomy, operating time, hospital days after operation and postoperative morbidity were compared between the two groups. The balloon occlusion group had significantly less blood loss, the volume of transfused blood products, caesarean hysterectomy, hospital day after operation than the control group had. There was no statistical difference in operating time, intensive care units (ICU), hypotension, infection, hypoxemia, bladder injury, bowel obstruction, neonatal asphyxia between the two groups. The balloon occlusion group had significantly higher rate in coagulopathy, hypoalbuminemia, electrolyte imbalance. Among the patients whose uterus were preserved, the blood loss was not significantly difference between the two groups. Among the patients with the complication of placenta accreta, caesarean hysterectomy was less in balloon group, and blood loss between the two groups was not significantly different. Among the patients without placenta accrete, the blood loss was less in balloon group, and caesarean hysterectomy between the two groups was not significantly different. The risk of hysterectomy in balloon group was related to placenta accreta, uterine arteries engorgement, placental invasive serosa, taking placenta by hand, placental invasive bladder, barrel-shaped thickening of lower uterine segment, unable to remove placenta. Internal iliac artery balloon occlusion is an effective treatment for pernicious placenta previa.

  14. Comparative study of proliferation kinetics of paramecium tetraurelia aboard a satellite and a balloon flight

    International Nuclear Information System (INIS)

    Tixador, Rene; Richoilley, Gerard; Gasset, Gilbert; Planel, Hubert

    1982-01-01

    A possible effect of cosmic rays on cell proliferation was investigated in cultures of Paramecium tetraurelia during a stratospheric balloon flight, with the techniques already used for the CYTOS experiments, performed aboard the orbital station Salyut 6. The results show that the stimulating effect of space on cell proliferation, reported in the CYTOS experiments, also occurs in the balloon flight. The respective roles of cosmic rays and weightlesness in the biological responses are discussed [fr

  15. Bakri balloon as a uterus preserving treatment of uncontrollable haemorrhage one month post-partum

    DEFF Research Database (Denmark)

    Bonnici, Mia; Markauskas, Algirdas; Munk, Torben

    2014-01-01

    In this case Bakri balloon was used to stop haemorrhage one month post-partum. The case introduces the use of this device outside usual indications. A 27-year-old woman was admitted several times with vaginal bleeding after caesarean section. She was treated pharmacologically and with curettage....... One month post-partum hysteroscopic removal of placental tissue was done. During this uncontrollable haemorrhage occurred and hysterectomy was considered. An attempt to save the uterus with Bakri balloon was made succesfully....

  16. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  17. Intraluminal pressure of uterine balloon tamponade in the management of severe post-partum hemorrhage.

    Science.gov (United States)

    Kong, Choi Wah; To, William W K

    2018-02-01

    Intrauterine balloon tamponade has been increasingly used for the management of post-partum hemorrhage (PPH) in recent years. However, data on the precise mechanisms and pressure required for the balloon tamponade are scanty in the literature. This study aims to review the intraluminal pressure (ILP) generated by the Bakri intrauterine balloon that is necessary to produce a 'positive tamponade test' during severe PPH. This was a prospective cohort study. The ILP of the Bakri balloon was measured using a manometer after a positive tamponade test was clinically achieved during severe PPH (blood loss >1 L). The patient's blood pressure was recorded, and ultrasound scan was performed to verify the position of the balloon and the presence of forward flow in the uterine arteries. The main outcome measure is the ILP of the Bakri balloon required to achieve a positive tamponade test. Twenty patients were included for final analysis. The net ILP measured ranged from 67 to 92 mmHg, and this pressure was lower than the concurrent systolic pressure in all cases. Color Doppler confirmed positive forward flow in the uterine vessels in all cases. There were no differences in the pressure measured with the balloon position, and there was no relationship between the volumes of saline infused and the net pressure. A positive tamponade test in an intrauterine balloon is probably achieved by local compression pressure exerted on the vasculature of the placental bed rather than by generating an ILP exceeding systemic blood pressure or by occlusion of flow to the uterine arteries. © 2018 Japan Society of Obstetrics and Gynecology.

  18. Successful Balloon-Occluded Retrograde Transvenous Obliteration for Gastric Varix Mainly Draining into the Pericardiophrenic Vein

    International Nuclear Information System (INIS)

    Kageyama, Ken; Nishida, N.; Matsui, H.; Yamamoto, A.; Nakamura, K.; Miki, Y.

    2012-01-01

    Two cases of gastric varices were treated by balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein at our hospital, and both were successful. One case developed left hydrothorax. Gastric varices did not bled and esophageal varices were not aggravated in both cases for 24–30 months thereafter. These outcomes indicate the feasibility of balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein.

  19. Exponential Stabilization of Underactuated Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Pettersen, K.Y.

    1996-12-31

    Underactuated vehicles are vehicles with fewer independent control actuators than degrees of freedom to be controlled. Such vehicles may be used in inspection of sub-sea cables, inspection and maintenance of offshore oil drilling platforms, and similar. This doctoral thesis discusses feedback stabilization of underactuated vehicles. The main objective has been to further develop methods from stabilization of nonholonomic systems to arrive at methods that are applicable to underactuated vehicles. A nonlinear model including both dynamics and kinematics is used to describe the vehicles, which may be surface vessels, spacecraft or autonomous underwater vehicles (AUVs). It is shown that for a certain class of underactuated vehicles the stabilization problem is not solvable by linear control theory. A new stability result for a class of homogeneous time-varying systems is derived and shown to be an important tool for developing continuous periodic time-varying feedback laws that stabilize underactuated vehicles without involving cancellation of dynamics. For position and orientation control of a surface vessel without side thruster a new continuous periodic feedback law is proposed that does not cancel any dynamics, and that exponentially stabilizes the origin of the underactuated surface vessel. A further issue considered is the stabilization of the attitude of an AUV. Finally, the thesis discusses stabilization of both position and attitude of an underactuated AUV. 55 refs., 28 figs.

  20. Development of a novel endorectal balloon for two-dimensional in-vivo rectal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Young Kyung; Jeang, Eun Hee; Min, Soon Ki; Cho, Kwan Ho [National Cancer Center, Goyang (Korea, Republic of); Hwang, Ui Jung [National Medical Center, Seoul (Korea, Republic of); Choi, Sang Hyoun [Korea Cancer Center Hospital, Seoul (Korea, Republic of); Kwak, Jung Won [Asan Medical Center, Seoul (Korea, Republic of)

    2016-05-15

    In the present study, a new endorectal balloon equipped with radiochromic film was developed, and its dosimetric property was evaluated. A metal-oxide-semiconductor field-effect transistor (MOSFET) was used in a rectal balloon to measure the rectal dose in 3D-CRT and IMRT. Additionally, a thermoluminescent dosimeter (TLD) was attached directly onto the rectal balloon to measure the rectal dose in IMRT and proton therapy. However, in vivo dosimetry that uses such point dosimeters cannot provide 2D dose distribution in a rectal wall (RW). In order to obtain the 2D dose distribution in the rectal wall, a 2D dosimeter that incorporates radiosensitive film is required. A new endorectal balloon capable of 2D in vivo rectal dosimetry was developed. Unlike conventional ERBs, this 2DD-ERB was equipped with a radiosensitive film on the outside of the balloon to directly measure the 2D dose distribution delivered to the ARW by the treatment beam. The dosimetric properties of the 2DD-ERB were measured, and the results showed that the measured dose distributions agreed well with their respective treatment plans within 4%. The film-equipped endorectal balloon is expected to be used as an in vivo dosimeter for measuring the dose distribution in the rectal wall in the modern radiotherapy techniques, such as IMRT, VMAT, HT, and IMPT.