WorldWideScience

Sample records for stability testing methods

  1. Standard Test Method for Dimensional Stability of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the sandwich core dimensional stability in the two plan dimensions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  4. Methods study of homogeneity and stability test from cerium oxide CRM candidate

    International Nuclear Information System (INIS)

    Samin; Susanna TS

    2016-01-01

    The methods study of homogeneity and stability test from cerium oxide CRM candidate has been studied based on ISO 13258 and KAN DP. 01. 34. The purpose of this study was to select the test method homogeneity and stability tough on making CRM cerium oxide. Prepared 10 sub samples of cerium oxide randomly selected types of analytes which represent two compounds, namely CeO 2 and La 2 O 3 . At 10 sub sample is analyzed CeO 2 and La 2 O 3 contents in duplicate with the same analytical methods, by the same analyst, and in the same laboratory. Data analysis results calculated statistically based on ISO 13528 and KAN DP.01.34. According to ISO 13528 Cerium Oxide samples said to be homogeneous if Ss ≤ 0.3 σ and is stable if | Xr – Yr | ≤ 0.3 σ. In this study, the data of homogeneity test obtained CeO 2 is Ss = 2.073 x 10-4 smaller than 0.3 σ (0.5476) and the stability test obtained | Xr - Yr | = 0.225 and the price is < 0.3 σ. Whereas for La 2 O 3 , the price for homogeneity test obtained Ss = 1.649 x 10-4 smaller than 0.3 σ (0.4865) and test the stability of the price obtained | Xr - Yr | = 0.2185 where the price is < 0.3 σ. Compared with the method from KAN, a sample of cerium oxide has also been homogenized for Fcalc < Ftable and stable, because | Xi - Xhm | < 0.3 x n IQR. Provided that the results of the evaluation homogeneity and stability test from CeO 2 CRM candidate test data were processed using statistical methods ISO 13528 is not significantly different with statistical methods from KAN DP.01.34, which together meet the requirements of a homogeneous and stable. So the test method homogeneity and stability test based on ISO 13528 can be used to make CRM cerium oxide. (author)

  5. An implementation and test platform for wide area stability assessment methods

    DEFF Research Database (Denmark)

    Wittrock, Martin Lindholm; Jóhannsson, Hjörtur

    2013-01-01

    This paper presents a software platform developed in MatLab with the purpose of supporting research, Development and testing of wide area algorithms for stability assessment and control. The development and testing process of algorithms exploiting real time wide area data from Phasor Measurement...... Units (PMU) can be very time consuming, especially if the testing procedure is not carried out in a systematic and automatic manner. The test platform overcomes this problem by automatically importing system model parameters, topology and simulation output from a time domain simulation of an instability...... scenario and automatically generating synthetic PMU snapshots of the system conditions. To demonstrate the platform’s potential for supporting research and development of wide area algorithms, a method to detect voltage instability is implemented and tested, giving results consistent with results from...

  6. A note on imperfect hedging: a method for testing stability of the hedge ratio

    Directory of Open Access Journals (Sweden)

    Michal Černý

    2012-01-01

    Full Text Available Companies producing, processing and consuming commodities in the production process often hedge their commodity expositions using derivative strategies based on different, highly correlated underlying commodities. Once the open position in a commodity is hedged using a derivative position with another underlying commodity, the appropriate hedge ratio must be determined in order the hedge relationship be as effective as possible. However, it is questionable whether the hedge ratio determined at the inception of the risk management strategy remains stable over the whole period for which the hedging strategy exists. Usually it is assumed that in the short run, the relationship (say, correlation between the two commodities remains stable, while in the long run it may vary. We propose a method, based on statistical theory of stability, for on-line detection whether market movements of prices of the commodities involved in the hedge relationship indicate that the hedge ratio may have been subject to a recent change. The change in the hedge ratio decreases the effectiveness of the original hedge relationship and creates a new open position. The method proposed should inform the risk manager that it could be reasonable to adjust the derivative strategy in a way reflecting the market conditions after the change in the hedge ratio.

  7. Fecal Collection and Stabilization Methods for Improved Fecal DNA Test for Colorectal Cancer in a Screening Setting

    Directory of Open Access Journals (Sweden)

    Francesca Maria Carozzi

    2013-01-01

    Full Text Available Early detection of CRC and adenomas reduces CRC-related mortality. The optimal screening test for CRC is still a subject of debate, and molecular stool sample analysis could provide a valid alternative to conventional methods in terms of compliance and practicability. Seven fecal DNA storage systems were evaluated in two successive phases. In the first phase of the study was selected the preservative buffer able to ensure the best human DNA recovery. In the second phase was evaluated human DNA stability, amplificability and integrity in DNA extracted from selected buffer. Results showed that the best performance was obtained in samples stored in 100 mM EDTA buffer and Genefec buffer. Likewise buffer addition yielded a significant increase in DNA stability and integrity without PCR inhibition, compared to the matched aliquots with no buffer added. Our study shows that samples collected in stabilization solution stabilize DNA so that intact nucleic acids, are more effectively detectable in the molecular assay. DNA buffer preservation and storage conditions could be useful to guarantee the most consistent yield in human DNA. Stabilization buffer addition to stool samples prior to transport presents an easily implemented solution that appears to be highly effective. Overall DNA extracted from faeces preserved in preservative buffer can feasibility been used for molecular analysis leading to an increase of assay sensitivity.

  8. METHOD FOR STABILIZING KLYSTRONS

    Science.gov (United States)

    Magnuson, D.W.; Smith, D.F.

    1959-04-14

    High-frequency oscillators for the generation of microwaves, particularly a system for stabilizing frequency-modulated klystron oscillators of the reflex type, are described. The system takos advantage of the fact that a change in oscillator frequency will alter the normal phase displacement between the cavity and its modulator, creating an error voltage which is utilized to regulate the frequency of the oscillator and stabilize it.

  9. Sludge stabilization operability test report

    International Nuclear Information System (INIS)

    Lewis, W.S.

    1994-01-01

    Document provides the results of the Operability Test Procedure performed to test the operability of the HC-21C thermal stabilization process for sludge. The OTP assured all equipment functioned properly and established the baseline temperature profile for glovebox HC-21C

  10. Stability of CIGS Solar Cells and Component Materials Evaluated by a Step-Stress Accelerated Degradation Test Method: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Pern, F. J.; Noufi, R.

    2012-10-01

    A step-stress accelerated degradation testing (SSADT) method was employed for the first time to evaluate the stability of CuInGaSe2 (CIGS) solar cells and device component materials in four Al-framed test structures encapsulated with an edge sealant and three kinds of backsheet or moisture barrier film for moisture ingress control. The SSADT exposure used a 15oC and then a 15% relative humidity (RH) increment step, beginning from 40oC/40%RH (T/RH = 40/40) to 85oC/70%RH (85/70) as of the moment. The voluminous data acquired and processed as of total DH = 3956 h with 85/70 = 704 h produced the following results. The best CIGS solar cells in sample Set-1 with a moisture-permeable TPT backsheet showed essentially identical I-V degradation trend regardless of the Al-doped ZnO (AZO) layer thickness ranging from standard 0.12 μm to 0.50 μm on the cells. No clear 'stepwise' feature in the I-V parameter degradation curves corresponding to the SSADT T/RH/time profile was observed. Irregularity in I-V performance degradation pattern was observed with some cells showing early degradation at low T/RH < 55/55 and some showing large Voc, FF, and efficiency degradation due to increased series Rs (ohm-cm2) at T/RH ≥ 70/70. Results of (electrochemical) impedance spectroscopy (ECIS) analysis indicate degradation of the CIGS solar cells corresponded to increased series resistance Rs (ohm) and degraded parallel (minority carrier diffusion/recombination) resistance Rp, capacitance C, overall time constant Rp*C, and 'capacitor quality' factor (CPE-P), which were related to the cells? p-n junction properties. Heating at 85/70 appeared to benefit the CIGS solar cells as indicated by the largely recovered CPE-P factor. Device component materials, Mo on soda lime glass (Mo/SLG), bilayer ZnO (BZO), AlNi grid contact, and CdS/CIGS/Mo/SLG in test structures with TPT showed notable to significant degradation at T/RH ≥ 70/70. At T/RH = 85/70, substantial blistering of

  11. Methods to measure stability of dental implants

    Directory of Open Access Journals (Sweden)

    Shruti Digholkar

    2014-01-01

    Full Text Available Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion and secondary stability (bone formation and remodeling at implant-bone interface. However, due to the invasive nature of the histological methods various other methods have been proposed: Radiographs, the surgeon′s perception, Insertion torque (cutting torque analysis, seating torque, reverse torque testing, percussion testing, impact hammer method, pulsed oscillation waveform, implant mobility checker, Periotest, resonance frequency analysis. This review focuses on the methods currently available for the evaluation of implant stability.

  12. Identification, synthesis and characterization of process related impurities of benidipine hydrochloride, stress-testing/stability studies and HPLC/UPLC method validations

    Directory of Open Access Journals (Sweden)

    Esen Bellur Atici

    2015-08-01

    Full Text Available Benidipine hydrochloride, used as an antihypertensive agent and long-acting calcium antagonist, is synthesized for commercial use as a drug substance in highly pure form. During the synthetic process development studies of benidipine, process related impurities were detected. These impurities were identified, synthesized and characterized and mechanisms of their formation were discussed in detail. After all standardization procedures, they were used as reference standards for analytical studies. In addition, a separate HPLC method was developed and validated for detection of residual 1-benzylpiperidin-3-ol (Ben-2, which is used during benidipine synthesis and controlled as a potential process related impurity. As complementary of this work, stress-testing studies of benidipine were carried out under specified conditions and a stability-indicating UPLC assay method was developed, validated and used during stability studies of benidipine. Keywords: Benidipine, Impurities, Synthesis, Characterization, Validation, Stability

  13. Improvement of a stability-indicating method by Quality-by-Design versus Quality-by-Testing: a case of a learning process.

    Science.gov (United States)

    Hubert, C; Lebrun, P; Houari, S; Ziemons, E; Rozet, E; Hubert, Ph

    2014-01-01

    The understanding of the method is a major concern when developing a stability-indicating method and even more so when dealing with impurity assays from complex matrices. In the presented case study, a Quality-by-Design approach was applied in order to optimize a routinely used method. An analytical issue occurring at the last stage of a long-term stability study involving unexpected impurities perturbing the monitoring of characterized impurities needed to be resolved. A compliant Quality-by-Design (QbD) methodology based on a Design of Experiments (DoE) approach was evaluated within the framework of a Liquid Chromatography (LC) method. This approach allows the investigation of Critical Process Parameters (CPPs), which have an impact on Critical Quality Attributes (CQAs) and, consequently, on LC selectivity. Using polynomial regression response modeling as well as Monte Carlo simulations for error propagation, Design Space (DS) was computed in order to determine robust working conditions for the developed stability-indicating method. This QbD compliant development was conducted in two phases allowing the use of the Design Space knowledge acquired during the first phase to define the experimental domain of the second phase, which constitutes a learning process. The selected working condition was then fully validated using accuracy profiles based on statistical tolerance intervals in order to evaluate the reliability of the results generated by this LC/ESI-MS stability-indicating method. A comparison was made between the traditional Quality-by-Testing (QbT) approach and the QbD strategy, highlighting the benefit of this QbD strategy in the case of an unexpected impurities issue. On this basis, the advantages of a systematic use of the QbD methodology were discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  15. Validation of methods on formalin testing in tofu and determination of 3,5-diacetyl-dihydrolutidine stability by UV-Vis spectrophotometry

    Science.gov (United States)

    Rohyami, Yuli; Pribadi, Rizki Maulana

    2017-12-01

    Formalin is a food preservative that is prohibited by the government, but the abuse of these chemicals is still widely found. The presence of formalin can be detected by using a typical reagent that can ensure the presence of formaldehyde qualitatively and quantitatively. This research was conducted to validate the method of determining formalin in tofu by using Nash reagent in UV-Vis spectrophotometry. The addition of Nash reagent will lead to the formation of diacetyldihydrolutidin complex. The study was performed by stability test of deacetyldihydrolutidine complex against time and pH. Validation of methods for formalin testing in tofu with diacetyldihydrolutidine by UV-Vis spectrophotometry. The results showed that 3,5-diacetyl-dihydrolutidine complex is stable at pH of 7 and stable in the range of 70-120 minutes. The validation shows that the method gives good precision and accuracy of 83.78%. The method has the limit of detection of 1.3681 µg/mL, limit of quantification of 4,5603 µg/mL, and the estimated uncertainty of measurement of 1.30 µg/mL. The test showed that the tofu contained formalin 3.09 ± 1.30 µg/mL. These values provide information that this method can be used as a procedure for the determination of formalin on tofu.

  16. Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength.

    Science.gov (United States)

    Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo

    2017-12-01

    Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (Pstrength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.

  17. 21 CFR 211.166 - Stability testing.

    Science.gov (United States)

    2010-04-01

    ... expiration dates provided full shelf life studies are not available and are being conducted. Where data from... shelf life studies, there must be stability studies conducted, including drug product testing at... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Stability testing. 211.166 Section 211.166 Food...

  18. Formulation and stability testing of photolabile drugs.

    Science.gov (United States)

    Tønnesen, H H

    2001-08-28

    Exposure of a drug to irradiation can influence the stability of the formulation, leading to changes in the physicochemical properties of the product. The influence of excipients of frequently used stabilizers is often difficult to predict and, therefore, stability testing of the final preparation is important. The selection of a protective packaging must be based on knowledge about the wavelength causing the instability. Details on drug photoreactivity will also be helpful in order to minimize side-effects and/or optimize drug targeting by developing photoresponsive drug delivery systems. This review focuses on practical problems related to formulation and stability testing of photolabile drugs.

  19. Simplified methods for evaluating road prism stability

    Science.gov (United States)

    William J. Elliot; Mark Ballerini; David Hall

    2003-01-01

    Mass failure is one of the most common failures of low-volume roads in mountainous terrain. Current methods for evaluating stability of these roads require a geotechnical specialist. A stability analysis program, XSTABL, was used to estimate the stability of 3,696 combinations of road geometry, soil, and groundwater conditions. A sensitivity analysis was carried out to...

  20. Test-Retest Stability of Word Retrieval in Aphasic Discourse

    Science.gov (United States)

    Boyle, Mary

    2014-01-01

    Purpose: This study examined the test-retest stability of select word-retrieval measures in the discourses of people with aphasia who completed a 5-stimulus discourse task. Method: Discourse samples across 3 sessions from 12 individuals with aphasia were analyzed for the stability of measures of informativeness, efficiency, main concepts, noun and…

  1. Automation for a base station stability testing

    OpenAIRE

    Punnek, Elvis

    2016-01-01

    This Batchelor’s thesis was commissioned by Oy LM Ericsson Ab Oulu. The aim of it was to help to investigate and create a test automation solution for the stability testing of the LTE base station. The main objective was to create a test automation for a predefined test set. This test automation solution had to be created for specific environments and equipment. This work included creating the automation for the test cases and putting them to daily test automation jobs. The key factor...

  2. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  3. Geophysical Methods for Monitoring Soil Stabilization Processes

    Science.gov (United States)

    Soil stabilization involves methods used to turn unconsolidated and unstable soil into a stiffer, consolidated medium that could support engineered structures, alter permeability, change subsurface flow, or immobilize contamination through mineral precipitation. Among the variety...

  4. Extrapolated stabilized explicit Runge-Kutta methods

    Science.gov (United States)

    Martín-Vaquero, J.; Kleefeld, B.

    2016-12-01

    Extrapolated Stabilized Explicit Runge-Kutta methods (ESERK) are proposed to solve multi-dimensional nonlinear partial differential equations (PDEs). In such methods it is necessary to evaluate the function nt times per step, but the stability region is O (nt2). Hence, the computational cost is O (nt) times lower than for a traditional explicit algorithm. In that way stiff problems can be integrated by the use of simple explicit evaluations in which case implicit methods usually had to be used. Therefore, they are especially well-suited for the method of lines (MOL) discretizations of parabolic nonlinear multi-dimensional PDEs. In this work, first s-stages first-order methods with extended stability along the negative real axis are obtained. They have slightly shorter stability regions than other traditional first-order stabilized explicit Runge-Kutta algorithms (also called Runge-Kutta-Chebyshev codes). Later, they are used to derive nt-stages second- and fourth-order schemes using Richardson extrapolation. The stability regions of these fourth-order codes include the interval [ - 0.01nt2, 0 ] (nt being the number of total functions evaluations), which are shorter than stability regions of ROCK4 methods, for example. However, the new algorithms neither suffer from propagation of errors (as other Runge-Kutta-Chebyshev codes as ROCK4 or DUMKA) nor internal instabilities. Additionally, many other types of higher-order (and also lower-order) methods can be obtained easily in a similar way. These methods also allow adaptation of the length step with no extra cost. Hence, the stability domain is adapted precisely to the spectrum of the problem at the current time of integration in an optimal way, i.e., with minimal number of additional stages. We compare the new techniques with other well-known algorithms with good results in very stiff diffusion or reaction-diffusion multi-dimensional nonlinear equations.

  5. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test method using a USP paddle type dissolution test apparatus set at a speed of. 50 rpm. The dissolution medium consisted of 900 ml of phosphate buffer (pH 6.8) containing 0.25% w/v cetrimide at 37 ...

  6. Test Bench Development for Femur Stability Assessment

    Directory of Open Access Journals (Sweden)

    Samuel SANCHEZ-CABALLERO

    2015-01-01

    Full Text Available This paper shows the design and development of a test bench for humanfemurs. The main uses of this test bench will run from artificial femurs comparisonwith real femurs, to join stability assessment after bone a fracture repair. Amongthis uses is specially designed for condylar fractures testing. The test bench isdeveloped from a self-made existing tensile/compression testing machine. Thedesign procedure is supported by a literature review about the bone mechanicalbehavior and composition generally and the knee joint performance and repairparticularly. On the basis of this review, the machine was designed to simulate theadduction and abduction movements of the joint. The magnitudes to be measuredare: the compression force, the bone displacement (vertical and the knee jointrotation

  7. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  8. Methods of stability analysis in nonlinear mechanics

    International Nuclear Information System (INIS)

    Warnock, R.L.; Ruth, R.D.; Gabella, W.; Ecklund, K.

    1989-01-01

    We review our recent work on methods to study stability in nonlinear mechanics, especially for the problems of particle accelerators, and compare our ideals to those of other authors. We emphasize methods that (1) show promise as practical design tools, (2) are effective when the nonlinearity is large, and (3) have a strong theoretical basis. 24 refs., 2 figs., 2 tabs

  9. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  10. Validated Stability-Indicating RP-HPLC Method for Simultaneous Determination of Clorsulon and Ivermectin Employing Plackett-Burman Experimental Design for Robustness Testing.

    Science.gov (United States)

    Saad, Ahmed S; Ismail, Nahla S; Soliman, Marwa; Zaazaa, Hala E

    2016-01-01

    A sensitive and highly selective stability-indicating gradient HPLC method was developed and validated for simultaneous determination of clorsulon (CLO) and ivermectin (IVM) in the presence of their degradation products. The drugs were subjected to different stress conditions, including acid and alkaline hydrolysis, oxidative, thermal, and photolytic forced degradation. The robustness of the proposed method was assessed using the Plackett-Burman experimental design, the factors affecting system performance were defined, and nonsignificant intervals for the significant factors were determined. The separation was carried out on a ZORBAX SB phenyl analytical column (250 × 4.6 mm id, 5 μm particle size), with gradient elution utilizing 10 mM sodium dihydrogen phosphate and acetonitrile as mobile phase. UV detection was performed for CLO and IVM at 254 nm over a concentration range of 4-140 and 5-50 μg/mL, respectively, with mean percentage recoveries of 99.90 ± 1.30 and 98.59 ± 1.16%, respectively. The proposed method was successfully applied to a pharmaceutical dosage form containing the investigated drugs. The results were statistically compared with the official HPLC methods, and no significant differences were found.

  11. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  12. Explicit strong stability preserving multistep Runge–Kutta methods

    KAUST Repository

    Bresten, Christopher

    2015-10-15

    High-order spatial discretizations of hyperbolic PDEs are often designed to have strong stability properties, such as monotonicity. We study explicit multistep Runge-Kutta strong stability preserving (SSP) time integration methods for use with such discretizations. We prove an upper bound on the SSP coefficient of explicit multistep Runge-Kutta methods of order two and above. Numerical optimization is used to find optimized explicit methods of up to five steps, eight stages, and tenth order. These methods are tested on the linear advection and nonlinear Buckley-Leverett equations, and the results for the observed total variation diminishing and/or positivity preserving time-step are presented.

  13. Stability of approximate factorization with $ heta $-methods

    NARCIS (Netherlands)

    W. Hundsdorfer (Willem)

    1997-01-01

    textabstractApproximate factorization seems for certain problems a viable alternative to time splitting. Since a splitting error is avoided, accuracy will in general be favourable compared to time splitting methods. However, it is not clear to what extent stability is affected by factorization.

  14. Numerical methods for hypersonic boundary layer stability

    Science.gov (United States)

    Malik, M. R.

    1990-01-01

    Four different schemes for solving compressible boundary layer stability equations are developed and compared, considering both the temporal and spatial stability for a global eigenvalue spectrum and a local eigenvalue search. The discretizations considered encompass: (1) a second-order-staggered finite-difference scheme; (2) a fourth-order accurate, two-point compact scheme; (3) a single-domain Chebychev spectral collocation scheme; and (4) a multidomain spectral collocation scheme. As Mach number increases, the performance of the single-domain collocation scheme deteriorates due to the outward movement of the critical layer; a multidomain spectral method is accordingly designed to furnish superior resolution of the critical layer.

  15. Stability Analysis Method of Parallel Inverter

    OpenAIRE

    Li, Jun; Chen, Jie; Xue, Yaru; Qiu, Ruichang; Liu, Zhigang

    2017-01-01

    In order to further provide theoretical support for the stability of an auxiliary inverter parallel system, a new model which covers most of control parameters needs to be established. However, the ability of the small-signal model established by the traditional method is extremely limited, so this paper proposes a new small-signal modeling method for the parallel system. The new small-signal model not only can analyze the influence of the droop parameters on the system performance, but also ...

  16. Stability Analysis Method of Parallel Inverter

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-01-01

    Full Text Available In order to further provide theoretical support for the stability of an auxiliary inverter parallel system, a new model which covers most of control parameters needs to be established. However, the ability of the small-signal model established by the traditional method is extremely limited, so this paper proposes a new small-signal modeling method for the parallel system. The new small-signal model not only can analyze the influence of the droop parameters on the system performance, but also can analyze the influence of the output impedance of the inverter, the unbalanced and nonlinear loads, and the power calculation method and cut-off frequency of the low-pass filter on the system performance and stability. Based on this method, this paper carries out a comprehensive analysis on the performance of a parallel inverter system. And the correctness of the modeling method and analysis process of the system performance and stability are verified by the consistency of the simulation and experimental results.

  17. RELAP-7 Numerical Stabilization: Entropy Viscosity Method

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Berry; M. O. Delchini; J. Ragusa

    2014-06-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL's modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5's capability and extends the analysis capability for all reactor system simulation scenarios. RELAP-7 utilizes a single phase and a novel seven-equation two-phase flow models as described in the RELAP-7 Theory Manual (INL/EXT-14-31366). The basic equation systems are hyperbolic, which generally require some type of stabilization (or artificial viscosity) to capture nonlinear discontinuities and to suppress advection-caused oscillations. This report documents one of the available options for this stabilization in RELAP-7 -- a new and novel approach known as the entropy viscosity method. Because the code is an ongoing development effort in which the physical sub models, numerics, and coding are evolving, so too must the specific details of the entropy viscosity stabilization method. Here the fundamentals of the method in their current state are presented.

  18. Coal - testing methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-04-01

    This Standard specifies the method for the particle-size analysis, the method for determination of the float and sink characteristics, the method for determination of Hardgrove grindability indices, the method for determination of the crucible swelling number, the method for determination of the swelling properties, the method for determination of the fluidity properties, the method for determination of the coking properties, the method for determination of the fusibility of ash, and the method for determination of Roga indices of coal.

  19. Chemical stability of enalapril maleate drug substance and tablets by a stability-indicating liquid chromatographic method

    OpenAIRE

    Diego,Marta de; Godoy,Gloria; Mennickent,Sigrid; Godoy,Ricardo

    2011-01-01

    The chemical stability of enalapril drug substance and tablets was studied by a stability-indicating liquid chromatographic method. Stress testing was performed on drug substance under various conditions. Accelerated stability testing was carried out for different formulations of enalapril tablets. Chromatographic separation was achieved on a RP-18 column, using a mobile phase of methanol phosphate buffer at 1.0 mL min"1 and UV detection. Degradation of the drug substance was greater under hy...

  20. Surface stabilization and revegetation test plots

    International Nuclear Information System (INIS)

    Sackschewsky, M.R.; Kemp, C.J.; Hayward, W.M.

    1993-09-01

    Westinghouse Hanford Company Decommissioning and Decontamination Engineering Group and Environmental Technology and Assessment Groups are developing new technologies to improve revegetation techniques for interim stabilization control over underground waste sites within the Radiation Area Remedial Action Program. Successful revegetation is an integral aspect of waste isolation strategy. Unfortunately, revegetation can be very difficult to achieve on the Hanford Site due to several factors: low annual precipitation, unpredictable timing of precipitation, low fertility of available soils, and coarse physical texture of soils covering waste sites. The tests in this report were performed during fiscal years 1992 and 1993 and include the use of two soil sealants in combination with bare soil and a soil/compost mixture and a comparison of a wheatgrass mixture and a native seed mixture. Hydroprobe access ports were placed in one-half of the test plots and moisture data was collected. Soil fertility and plant community characteristics were monitored during the two years of the test. During the first year all sites with compost provided additional fertility and retained greater amounts of soil moisture than noncomposted sites. The use of Enduraseal soil fixative provided greater soil moisture than the use of Aerospray-77 soil fixative. During the second year the use of compost and soil fixative's had a lesser effect on soil moisture. During late summer periods all treatments had very similar soil moisture profiles. The use of compost greatly increased vegetative cover and soil fertility in comparison to sites that had no compost added. Testing of the seed mixtures found that Siberian wheatgrass and Sandberg's bluegrass were the most dominant of the seeded species observed. All plots exhibited a dominant plant cover of volunteer cheatgrass. Biomass production was significantly greater on plots with compost than on the noncomposted plots

  1. Method of strengthening and stabilizing compressible soils

    Energy Technology Data Exchange (ETDEWEB)

    Casagrande, L.; Loughney, R.W.

    1968-06-04

    A method and means are described for stabilizing soil, consisting essentially of spacing holes about an area of the soil which is to be strengthened and stabilized. Each hole has placed therein a pipe which may be of approximately 2 to 4 in. in diam. Each pipe is provided with an expandable member capable of being expanded to a diameter of several feet. After the pipe with the expandable member fixed to it is placed in the hole, sand is placed around it, filling the sapce between the exterior walls of the expandable member and the walls of the hole, thus forming a sand drain. Thereafter the expandable member is put under pressure and expanded against the walls of the hole, placing pressure upon the soil and causing the water to be drained therefrom into the sand drains through which it rises to the surface and many be disposed of. (14 claims)

  2. Core stability: inter- and intraobserver reliability of 6 clinical tests

    NARCIS (Netherlands)

    Weir, Adam; Darby, Jennifer; Inklaar, Han; Koes, Bart; Bakker, Erik; Tol, Johannes L.

    2010-01-01

    Core stability is a complex concept within sports medicine and is thought to play a role in sports injuries. There is a lack of reliable and valid clinical tests for core stability. The inter- and intraobserver reliability of 6 tests commonly used to assess core stability was determined. A video of

  3. Efficiency and stability of the DSBGK method

    KAUST Repository

    Li, Jun

    2012-07-09

    Recently, the DSBGK method (Note: the original name DS-BGK is changed to DSBGK for simplicity) was proposed to reduce the stochastic noise in simulating rarefied gas flows at low velocity. Its total computational time is almost independent of the magnitude of deviation from equilibrium state. It was verified by the DSMC method in different benchmark problems over a wide range of Kn number. Some simulation results of the closed lid-driven cavity flow, thermal transpiration flow and the open channel flow by the DSBGK method are given here to show its efficiency and numerical stability. In closed problems, the density distribution is subject to unphysical fluctuation due to the absence of density constraint at the boundary. Thus, many simulated molecules are employed by DSBGK simulations to improve the stability and reduce the magnitude of fluctuation. This increases the memory usage remarkably but has small influence to the efficiency of DSBGK simulations. In open problems, the DSBGK simulation remains stable when using about 10 simulated molecules per cell because the fixed number densities at open boundaries eliminate the unphysical fluctuation. Small modification to the CLL reflection model is introduced to further improve the efficiency slightly.

  4. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  5. Stabilizing the thermal lattice Boltzmann method by spatial filtering.

    Science.gov (United States)

    Gillissen, J J J

    2016-10-01

    We propose to stabilize the thermal lattice Boltzmann method by filtering the second- and third-order moments of the collision operator. By means of the Chapman-Enskog expansion, we show that the additional numerical diffusivity diminishes in the low-wavnumber limit. To demonstrate the enhanced stability, we consider a three-dimensional thermal lattice Boltzmann system involving 33 discrete velocities. Filtering extends the linear stability of this thermal lattice Boltzmann method to 10-fold smaller transport coefficients. We further demonstrate that the filtering does not compromise the accuracy of the hydrodynamics by comparing simulation results to reference solutions for a number of standardized test cases, including natural convection in two dimensions.

  6. Surface stability test plan for protective barriers

    International Nuclear Information System (INIS)

    Ligotke, M.W.

    1989-01-01

    Natural-material protective barriers for long-term isolation of buried waste have been identified as integral components of a plan to isolate a number of Hanford defense waste sites. Standards currently being developed for internal and external barrier performance will mandate a barrier surface layer that is resistant to the eolian erosion processes of wind erosion (deflation) and windborne particle deposition (formation of sand dunes). Thus, experiments are needed to measure rates of eolian erosion processes impacting those surfaces under different surface and climatological conditions. Data from these studies will provide information for use in the evaluation of selected surface layers as a means of providing stable cover over waste sites throughout the design life span of protective barriers. The multi-year test plan described in this plan is directed at understanding processes of wind erosion and windborne particle deposition, providing measurements of erosion rates for models, and suggesting construction materials and methods for reducing the effect of long-term eolian erosion on the barrier. Specifically, this plan describes possible methods to measure rates of eolian erosion, including field and laboratory procedure. Advantages and disadvantages of laboratory (wind tunnel) tests are discussed, and continued wind tunnel tests are recommended for wind erosion studies. A comparison between field and wind tunnel erosive forces is discussed. Plans for testing surfaces are described. Guidance is also presented for studying the processes controlling sand dune and blowout formation. 24 refs., 7 figs., 3 tabs

  7. Uncertainty considerations for interferometric stability testing

    NARCIS (Netherlands)

    Ellis, J.D.; Joo, K.N.; Verlaan, A.L.; Spronck, J.W.

    2008-01-01

    Material stability is an important parameter for EUV lithography, space instrumentation, and metrology in general. In both EUV lithography and space, more information is needed about material stability during an atmospheric to vacuum transition. For metrology instruments in general, determining the

  8. Reassessing Solar Wind Stability using Nyquist's Method

    Science.gov (United States)

    Klein, Kristopher; Kasper, Justin; Alterman, Benjamin; Stevens, Michael; Korreck, Kelly

    2017-10-01

    In nearly-collisionless plasmas, such as the solar wind, non-local thermodynamic equilibrium structures, including temperature anisotropies, beam populations with relative drifts, and agyrotropic features, are frequently observed to persist. These features can act as sources of free energy which may drive instabilities that move the plasma closer to LTE. Analysis techniques applied to solar wind observations for the presence of such instabilities typically consider only a single source of free energy, such the temperature anisotropy of the proton population. We have developed an efficient algorithm for general determination of linear stability considering all sources of free energy using Nyquist's Method. By applying this method to the dispersion relation associated with a particular solar wind observation, we rapidly determine if the plasma is linearly unstable, and if so, how many normal modes are driven. Our technique is verified against well-characterized theoretical and observational cases from the literature, and applied to in situ observations from the Wind spacecraft to determine how additional sources of free energy affect the plasma's stability and may govern the solar wind's evolution.

  9. Test system and method

    DEFF Research Database (Denmark)

    2012-01-01

    at a second distance from the centre, the second distance being larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged...... larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged for sensing the at least one optical detectable member...

  10. METHOD FOR TESTING COATINGS

    Science.gov (United States)

    Johns, I.B.; Newton, A.S.

    1958-09-01

    A method is described for detecting pin hole imperfections in coatings on uranium-metal objects. Such coated objects are contacted with a heated atmosphere of gaseous hydrogen and imperfections present in the coatings will allow the uranlum to react with the hydrogen to form uranium hydride. Since uranium hydride is less dense than uranium metal it will swell, causing enlargement of the coating defeot and rendering it visible.

  11. Image Registration for Stability Testing of MEMS

    Science.gov (United States)

    Memarsadeghi, Nargess; LeMoigne, Jacqueline; Blake, Peter N.; Morey, Peter A.; Landsman, Wayne B.; Chambers, Victor J.; Moseley, Samuel H.

    2011-01-01

    Image registration, or alignment of two or more images covering the same scenes or objects, is of great interest in many disciplines such as remote sensing, medical imaging. astronomy, and computer vision. In this paper, we introduce a new application of image registration algorithms. We demonstrate how through a wavelet based image registration algorithm, engineers can evaluate stability of Micro-Electro-Mechanical Systems (MEMS). In particular, we applied image registration algorithms to assess alignment stability of the MicroShutters Subsystem (MSS) of the Near Infrared Spectrograph (NIRSpec) instrument of the James Webb Space Telescope (JWST). This work introduces a new methodology for evaluating stability of MEMS devices to engineers as well as a new application of image registration algorithms to computer scientists.

  12. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (pTest-retest reliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  13. Stability Testing of Beclomethasone Dipropionate Nanoemulsion ...

    African Journals Online (AJOL)

    The nanoemulsions were characterized by droplet size, pH, viscosity, conductivity and refractive index. Stability studies were performed according to International Council on Harmonization (ICH) guidelines over a period of 3 months. Droplet size, pH, viscosity, conductivity and refractive index were determined monthly for 3 ...

  14. Centrifuge model test of rock slope failure caused by seismic excitation. Applicability to the stability evaluation method of safety factors against sliding

    International Nuclear Information System (INIS)

    Ishimaru, Makoto; Kawai, Tadashi

    2010-01-01

    The purposes of this study are to analyze dynamic failure characteristics of slopes in discontinuous rock mass with brittle fracture by centrifuge model tests and to study applicability to the equivalent linear analysis against dynamic sliding failure of rock slopes. We conducted centrifuge model test using a dip slope model with discontinuities imitated by Teflon sheets. The centrifugal acceleration was 30G, and the acceleration amplitudes of input sin waves were increased gradually at every step. The test results were compared with safety factors of the sliding surface based on the equivalent linear analysis. The following results were obtained: (1) The slope model collapsed when it was excited by the sine wave of 350gal, which was converted to real field scale. (2) Artificial discontinuities considerably affected the collapse, and the type of collapse was plane failure. (3) From response displacement records measured at the slope model, the failure around toe of the slope model probably caused the collapse. (4) The evaluation of safety factors against sliding based on the equivalent linear analysis were conservative compared with the experimental results. (author)

  15. Univariate stability analysis methods for determining genotype ...

    African Journals Online (AJOL)

    Twenty two different stability statistics were used for analyzing genotype × environment (GE) interaction of durum wheat experimental data (20 genotypes in 15 environments). Combined analysis of variance indicated that GE interaction significantly influenced genotypes yield. According to type I stability concept, genotypes ...

  16. Chemical stability of enalapril maleate drug substance and tablets by a stability-indicating liquid chromatographic method

    Directory of Open Access Journals (Sweden)

    Marta de Diego

    2011-01-01

    Full Text Available The chemical stability of enalapril drug substance and tablets was studied by a stability-indicating liquid chromatographic method. Stress testing was performed on drug substance under various conditions. Accelerated stability testing was carried out for different formulations of enalapril tablets. Chromatographic separation was achieved on a RP-18 column, using a mobile phase of methanol phosphate buffer at 1.0 mL min"1 and UV detection. Degradation of the drug substance was greater under hydrolytic conditions. After 180 days of accelerated stability testing most enalapril tablets showed more than 10% of degradation. Enalapril drug substance and tablets showed instability under stress and accelerated testing respectively, with possible implications on the therapeutic activity.

  17. Unidirectional Fabric Drape Testing Method.

    Science.gov (United States)

    Mei, Zaihuan; Shen, Wei; Wang, Yan; Yang, Jingzhi; Zhou, Ting; Zhou, Hua

    2015-01-01

    In most cases, fabrics such as curtains, skirts, suit pants and so on are draped under their own gravity parallel to fabric plane while the gravity is perpendicular to fabric plane in traditional drape testing method. As a result, it does not conform to actual situation and the test data is not convincing enough. To overcome this problem, this paper presents a novel method which simulates the real mechanical conditions and ensures the gravity is parallel to the fabric plane. This method applied a low-cost Kinect Sensor device to capture the 3-dimensional (3D) drape profile, thus we obtained the drape degree parameters and aesthetic parameters by 3D reconstruction and image processing and analysis techniques. The experiment was conducted on our self-devised drape-testing instrument by choosing different kinds of weave structure fabrics as our testing samples and the results were compared with those of traditional method and subjective evaluation. Through regression and correlation analysis we found that this novel testing method was significantly correlated with the traditional and subjective evaluation method. We achieved a new, non-contact 3D measurement method for drape testing, namely unidirectional fabric drape testing method. This method is more suitable for evaluating drape behavior because it is more in line with actual mechanical conditions of draped fabrics and has a well consistency with the requirements of visual and aesthetic style of fabrics.

  18. Element diameter free stability parameters for stabilized methods applied to fluids

    International Nuclear Information System (INIS)

    Franca, L.P.; Madureira, A.L.

    1992-08-01

    Stability parameters for stabilized methods in fluids are suggested. The computation of the largest eigenvalue of a generalized eigenvalue problem replaces controversial definitions of element diameters and inverse estimate constants, used heretofore to compute these stability parameters. The design is employed in the advective-diffusive model, incompressible Navier-Stokes equations and the Stokes problem. (author)

  19. Consensus stability testing protocols for organic photovoltaic materials and devices

    DEFF Research Database (Denmark)

    Reese, Matthew O.; Gevorgyan, Suren; Jørgensen, Mikkel

    2011-01-01

    Procedures for testing organic solar cell devices and modules with respect to stability and operational lifetime are described. The descriptions represent a consensus of the discussion and conclusions reached during the first 3 years of the international summit on OPV stability (ISOS). The proced...

  20. An alternative method to specify the degree of resonator stability

    Indian Academy of Sciences (India)

    Abstract. We present an alternative method to specify the stability of real stable res- onators. We introduce the degree of optical stability or the S parameter, which specify the stability of resonators in a numerical scale ranging from 0 to 100%. The value of zero corresponds to marginally stable resonator and S < 0 ...

  1. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  2. Generator Set Environmental and Stability Testing

    Science.gov (United States)

    2015-03-01

    EOT End of Test HFRR High Frequency Reciprocating Rig HRJ-8 Hydro-Renewable Jet Fuel JFTOT Jet Fuel Thermal Oxidation Test kW kilo Watts MEP... Jet -A. The blend was additized with 22.5 ppm DCI-4A and 1 ppm STADIS to bring the blend into conformance with the MIL-DTL-83133G specification. As...Muff psia psia 13.96 1.468 Exh Cyl 3 F 751.9 1.00 Exh Cyl 4 F 763.8 0.97 Power kW 15.6 Exh Manifold F 797.6 0.63 Voltage L1 V 119.2 0.07 After Turbo

  3. System and method for determining stability of a neural system

    Science.gov (United States)

    Curtis, Steven A. (Inventor)

    2011-01-01

    Disclosed are methods, systems, and computer-readable media for determining stability of a neural system. The method includes tracking a function world line of an N element neural system within at least one behavioral space, determining whether the tracking function world line is approaching a psychological stability surface, and implementing a quantitative solution that corrects instability if the tracked function world line is approaching the psychological stability surface.

  4. A Stability Indicating HPLC Method for the Determination of ...

    African Journals Online (AJOL)

    Erah

    stability indicating reverse phase HPLC method for estimating meloxicam (MLX) in bulk and commercial preparations. Method: ... were performed. The drug was subjected to stress degradation studies under acidic, basic and oxidative conditions. ... forms as well as biological fluids; however, not all of these are stability ...

  5. Application of Lyapunov's Second Method in the Stability Analysis of ...

    African Journals Online (AJOL)

    In this paper, Lyapunov's method for determining the stability of non-linear systems under dynamic states is presented. The paper highlights a practical application of the method to investigate the stability of crude oil/natural gas separation process. Mathematical state models for the separation process, used in the ...

  6. Testing framework for compression methods

    OpenAIRE

    Štoček, Ondřej

    2008-01-01

    There are many algorithms for data compression. These compression methods often achieve different compression rate and also use computer resources differently. In practice a combination of compression is usually used instead of standalone compression methods. The software tool can be evolved, where we can easily combine existing compression methods to new one and test it consequently. Main goal of this work is to propound such tool and implement it. Further goal is to implement basic library ...

  7. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  8. Power stability methods for parallel systems

    International Nuclear Information System (INIS)

    Wallach, Y.

    1988-01-01

    Parallel-Processing Systems are already commercially available. This paper shows that if one of them - the Alternating Sequential Parallel, or ASP system - is applied to network stability calculations it will lead to a higher speed of solution. The ASP system is first described and is then shown to be cheaper, more reliable and available than other parallel systems. Also, no deadlock need be feared and the speedup is normally very high. A number of ASP systems were already assembled (the SMS systems, Topps, DIRMU etc.). At present, an IBM Local Area Network is being modified so that it too can work in the ASP mode. Existing ASP systems were programmed in Fortran or assembly language. Since newer systems (e.g. DIRMU) are programmed in Modula-2, this language can be used. Stability analysis is based on solving nonlinear differential and algebraic equations. The algorithm for solving the nonlinear differential equations on ASP, is described and programmed in Modula-2. The speedup is computed and is shown to be almost optimal

  9. Stability by Liapunov's direct methods with applications

    CERN Document Server

    Salle, Joseph La

    1961-01-01

    In this book, we study theoretical and practical aspects of computing methods for mathematical modelling of nonlinear systems. A number of computing techniques are considered, such as methods of operator approximation with any given accuracy; operator interpolation techniques including a non-Lagrange interpolation; methods of system representation subject to constraints associated with concepts of causality, memory and stationarity; methods of system representation with an accuracy that is the best within a given class of models; methods of covariance matrix estimation;methods for low-rank mat

  10. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  11. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  12. Stability Analysis of a Rigid Body with a Flexible Attachment Using the Energy-Casimir Method

    OpenAIRE

    Posbergh, T. A.; Krishnaprasad, Perinkulam S.; Marsden, Jerrold E.

    1987-01-01

    We consider a system consisting of a rigid body to which a linear extensible shear beam is attached. For such a system the Energy-Casimir method can be used to investigate the stability of the equilibria. In the case we consider, it can be shown that a test for (formal) stability reduces to checking the positive definiteness of two matrices which depend on the parameters of the system and the particular equilibrium about which the stability is to be ascertained.

  13. Stability estimates for hp spectral element methods for general ...

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences; Volume 113; Issue 4. Stability Estimates for ℎ- Spectral ... We establish basic stability estimates for a non-conforming ℎ- spectral element method which allows for simultaneous mesh refinement and variable polynomial degree. The spectral element functions are ...

  14. Progress on Biochar Preparation and Its Assessement Methods of Stability

    Directory of Open Access Journals (Sweden)

    JIN Liang

    2015-10-01

    Full Text Available As a promising pyrolysis product for mitigating climate changes, biochar can be remained in soil for thousands years after field application. The positive benefits of biochar amendment into soil include crop yield increase, soil fertility improvement and water-holding capacity enhancement. The objective of this study is to quantify specific stability of the biochar by screening the relative documents towards directions including feedstock classification, biochar preparation, unique stability, etc. Finally three types of methods were summarized, such as indirect measurement methods, direct measurement methods and molecule properties methods for biochar stability, which resulted from various production conditions and feedstocks. Wide range of biochar feedstocks and specific stability of biochar preparation required new evaluation mechanism in order to evaluate prospect of biochar production process and relative soil amelioration and limitation with multiple perspectives.

  15. Stability-Indicating HPLC Method for the Simultaneous ...

    African Journals Online (AJOL)

    phase HPLC stability- indicating method for the simultaneous estimation of ... It is a class of lipid-lowering agent that selectively inhibits the intestinal ... room temperature, neutralised (for acidic and basic degradation) and diluted with the mobile.

  16. Stability analysis of CMFD acceleration for the wavelet expansion method of neutron transport equation

    International Nuclear Information System (INIS)

    Zheng Youqi; Wu Hongchun; Cao Liangzhi

    2013-01-01

    This paper describes the stability analysis for the coarse mesh finite difference (CMFD) acceleration used in the wavelet expansion method. The nonlinear CMFD acceleration scheme is transformed by linearization and the Fourier ansatz is introduced into the linearized formulae. The spectral radius is defined as the stability criterion, which is the least upper bound (LUB) of the largest eigenvalue of Fourier analysis matrix. The stability analysis considers the effect of mesh size (spectral length), coarse mesh division and scattering ratio. The results show that for the wavelet expansion method, the CMFD acceleration is conditionally stable. The small size of fine mesh brings stability and fast convergent. With the increase of the mesh size, the stability becomes worse. The scattering ratio does not impact the stability obviously. It makes the CMFD acceleration highly efficient in the strong scattering case. The results of Fourier analysis are verified by the numerical tests based on a homogeneous slab problem.

  17. On the numerical stability analysis of pipelined Krylov subspace methods

    Czech Academy of Sciences Publication Activity Database

    Carson, E.T.; Rozložník, Miroslav; Strakoš, Z.; Tichý, P.; Tůma, M.

    submitted 2017 (2018) R&D Projects: GA ČR GA13-06684S Grant - others:GA MŠk(CZ) LL1202 Institutional support: RVO:67985807 Keywords : Krylov subspace methods * the conjugate gradient method * numerical stability * inexact computations * delay of convergence * maximal attainable accuracy * pipelined Krylov subspace methods * exascale computations

  18. Data Fusion Modeling for an RT3102 and Dewetron System Application in Hybrid Vehicle Stability Testing

    OpenAIRE

    Zhibin Miao; Hongtian Zhang

    2015-01-01

    More and more hybrid electric vehicles are driven since they offer such advantages as energy savings and better active safety performance. Hybrid vehicles have two or more power driving systems and frequently switch working condition, so controlling stability is very important. In this work, a two-stage Kalman algorithm method is used to fuse data in hybrid vehicle stability testing. First, the RT3102 navigation system and Dewetron system are introduced. Second, a modeling of data fusion is p...

  19. Investigation of Indoor Stability Testing of Polymer Solar Cell

    Directory of Open Access Journals (Sweden)

    Pelin Kavak

    2016-01-01

    Full Text Available We have fabricated organic solar cell of a new low bandgap polymer poly[4,4-bis(2-ethylhexyl-4H-cyclopenta[2,1-b:3,4-b′]dithiophene-2,6-diyl-alt-4,7-bis(2-thienyl-2,1,3-benzothiadiazole-5′,5′′-diyl] (PCPDTTBTT. We have investigated for the first time the stability tests, ISOS-L-1 and ISOS-D-3, of PCPDTTBTT solar cells. Thermal annealing of PCPDTTBTT solar cells at 80°C brought about an improvement of photocurrent generation, stability, and efficiency of the solar cells. T80 value of PCPDTTBTT solar cell is about 150 hours which is close to P3HT (235 h. PCPDTTBTT is very promising polymer for both polymer solar cell efficiency and stability.

  20. Real stabilization method for nuclear single-particle resonances

    International Nuclear Information System (INIS)

    Zhang Li; Zhou Shangui; Meng Jie; Zhao Enguang

    2008-01-01

    We develop the real stabilization method within the framework of the relativistic mean-field (RMF) model. With the self-consistent nuclear potentials from the RMF model, the real stabilization method is used to study single-particle resonant states in spherical nuclei. As examples, the energies, widths, and wave functions of low-lying neutron resonant states in 120 Sn are obtained. These results are compared with those from the scattering phase-shift method and the analytic continuation in the coupling constant approach and satisfactory agreements are found

  1. Operational stability prediction in milling based on impact tests

    Science.gov (United States)

    Kiss, Adam K.; Hajdu, David; Bachrathy, Daniel; Stepan, Gabor

    2018-03-01

    Chatter detection is usually based on the analysis of measured signals captured during cutting processes. These techniques, however, often give ambiguous results close to the stability boundaries, which is a major limitation in industrial applications. In this paper, an experimental chatter detection method is proposed based on the system's response for perturbations during the machining process, and no system parameter identification is required. The proposed method identifies the dominant characteristic multiplier of the periodic dynamical system that models the milling process. The variation of the modulus of the largest characteristic multiplier can also be monitored, the stability boundary can precisely be extrapolated, while the manufacturing parameters are still kept in the chatter-free region. The method is derived in details, and also verified experimentally in laboratory environment.

  2. Stability-indicating methods for the determination of sertaconazole ...

    African Journals Online (AJOL)

    Two sensitive and selective stability-indicating methods were developed for the determination of sertaconazole nitrate (Ser-NO3), in the presence of its acid, alkaline and oxidative degradation products. The first method was based on measuring the fluorescence intensity of the drug at λex/λem = 231 nm/312 nm.

  3. Stability estimates for hp spectral element methods for elliptic ...

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences; Volume 112; Issue 4. Stability Estimates for ℎ- Spectral Element Methods for Elliptic Problems. Pravir Dutt ... In a series of papers of which this is the first we study how to solve elliptic problems on polygonal domains using spectral methods on parallel computers.

  4. Optimal Strong-Stability-Preserving Runge–Kutta Time Discretizations for Discontinuous Galerkin Methods

    KAUST Repository

    Kubatko, Ethan J.

    2013-10-29

    Discontinuous Galerkin (DG) spatial discretizations are often used in a method-of-lines approach with explicit strong-stability-preserving (SSP) Runge–Kutta (RK) time steppers for the numerical solution of hyperbolic conservation laws. The time steps that are employed in this type of approach must satisfy Courant–Friedrichs–Lewy stability constraints that are dependent on both the region of absolute stability and the SSP coefficient of the RK method. While existing SSPRK methods have been optimized with respect to the latter, it is in fact the former that gives rise to stricter constraints on the time step in the case of RKDG stability. Therefore, in this work, we present the development of new “DG-optimized” SSPRK methods with stability regions that have been specifically designed to maximize the stable time step size for RKDG methods of a given order in one space dimension. These new methods represent the best available RKDG methods in terms of computational efficiency, with significant improvements over methods using existing SSPRK time steppers that have been optimized with respect to SSP coefficients. Second-, third-, and fourth-order methods with up to eight stages are presented, and their stability properties are verified through application to numerical test cases.

  5. Soil Stabilization Methods with Potential for Application at the Nevada National Security Site: A Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Shillito, Rose [DRI; Fenstermaker, Lynn [DRI

    2014-01-01

    Nuclear testing at the Nevada National Security Site (NNSS) has resulted in large areas of surficial radionuclide-contaminated soils. Much of the radionuclide contamination is found at or near the soil surface, and due to the dry climate setting, and the long half-life of radioactive isotopes, soil erosion poses a long-term health risk at the NNSS. The objective of this literature review is to present a survey of current stabilization methods used for minimizing soil erosion, both by water and wind. The review focuses on in situ uses of fundamental chemical and physical mechanisms for soil stabilization. A basic overview of the physical and chemical properties of soil is also presented to provide a basis for assessing stabilization methods. Some criteria for stabilization evaluation are identified based on previous studies at the NNSS. Although no specific recommendations are presented as no stabilization method, alone or in combination, will be appropriate in all circumstances, discussions of past and current stabilization procedures and specific soil tests that may aid in current or future soil stabilization activities at the NNSS are presented. However, not all Soils Corrective Action Sites (CASs) or Corrective Action Units (CAUs) will require stabilization of surficial radionuclide-contaminated soils. Each Soils CAS or CAU should be evaluated for site-specific conditions to determine if soil stabilization is necessary or practical for a given specific site closure alternative. If stabilization is necessary, then a determination will be made as to which stabilization technique is the most appropriate for that specific site.

  6. Nonlinear stability and time step selection for the MPM method

    Science.gov (United States)

    Berzins, Martin

    2018-01-01

    The Material Point Method (MPM) has been developed from the Particle in Cell (PIC) method over the last 25 years and has proved its worth in solving many challenging problems involving large deformations. Nevertheless there are many open questions regarding the theoretical properties of MPM. For example in while Fourier methods, as applied to PIC may provide useful insight, the non-linear nature of MPM makes it necessary to use a full non-linear stability analysis to determine a stable time step for MPM. In order to begin to address this the stability analysis of Spigler and Vianello is adapted to MPM and used to derive a stable time step bound for a model problem. This bound is contrasted against traditional Speed of sound and CFL bounds and shown to be a realistic stability bound for a model problem.

  7. Stability Analysis of Nonuniform Rectangular Beams Using Homotopy Perturbation Method

    Directory of Open Access Journals (Sweden)

    Seval Pinarbasi

    2012-01-01

    Full Text Available The design of slender beams, that is, beams with large laterally unsupported lengths, is commonly controlled by stability limit states. Beam buckling, also called “lateral torsional buckling,” is different from column buckling in that a beam not only displaces laterally but also twists about its axis during buckling. The coupling between twist and lateral displacement makes stability analysis of beams more complex than that of columns. For this reason, most of the analytical studies in the literature on beam stability are concentrated on simple cases: uniform beams with ideal boundary conditions and simple loadings. This paper shows that complex beam stability problems, such as lateral torsional buckling of rectangular beams with variable cross-sections, can successfully be solved using homotopy perturbation method (HPM.

  8. Signal Processing Methods for Liquid Rocket Engine Combustion Stability Assessments

    Science.gov (United States)

    Kenny, R. Jeremy; Lee, Erik; Hulka, James R.; Casiano, Matthew

    2011-01-01

    The J2X Gas Generator engine design specifications include dynamic, spontaneous, and broadband combustion stability requirements. These requirements are verified empirically based high frequency chamber pressure measurements and analyses. Dynamic stability is determined with the dynamic pressure response due to an artificial perturbation of the combustion chamber pressure (bomb testing), and spontaneous and broadband stability are determined from the dynamic pressure responses during steady operation starting at specified power levels. J2X Workhorse Gas Generator testing included bomb tests with multiple hardware configurations and operating conditions, including a configuration used explicitly for engine verification test series. This work covers signal processing techniques developed at Marshall Space Flight Center (MSFC) to help assess engine design stability requirements. Dynamic stability assessments were performed following both the CPIA 655 guidelines and a MSFC in-house developed statistical-based approach. The statistical approach was developed to better verify when the dynamic pressure amplitudes corresponding to a particular frequency returned back to pre-bomb characteristics. This was accomplished by first determining the statistical characteristics of the pre-bomb dynamic levels. The pre-bomb statistical characterization provided 95% coverage bounds; these bounds were used as a quantitative measure to determine when the post-bomb signal returned to pre-bomb conditions. The time for post-bomb levels to acceptably return to pre-bomb levels was compared to the dominant frequency-dependent time recommended by CPIA 655. Results for multiple test configurations, including stable and unstable configurations, were reviewed. Spontaneous stability was assessed using two processes: 1) characterization of the ratio of the peak response amplitudes to the excited chamber acoustic mode amplitudes and 2) characterization of the variability of the peak response

  9. Surpassing the energy method for nonlinear fluid stability

    Science.gov (United States)

    Goluskin, David; Fuentes, Federico

    2017-11-01

    A basic question in fluid stability is whether a laminar flow is nonlinearly stable to all perturbations. The typical way to verify stability, called the energy method, is to show that the energy of a perturbation must decay monotonically. The energy method is known to be overly conservative in many systems, particularly when turbulence arises subcritically, such as in parallel shear flows. The energy method is a special case of a Lyapunov function method in which the Lyapunov function is the perturbation energy. This talk will present a more general approach in which the Lyapunov functions (1) are not restricted to being quadratic but instead are higher-degree polynomials, and (2) can depend explicitly on the spectrum of the velocity field in the eigenbasis of the energy stability operator. The optimal construction of such Lyapunov functions is complicated but can be done with computer assistance by formulating a polynomial optimization problem, which in turn is formulated as a semidefinite program. This talk will describe the general framework of the method. A companion talk by Federico Fuentes will illustrate its application to planar Couette flow, where we have verified nonlinear stability at larger Reynolds numbers than is possible using the energy method.

  10. Method for enhancing the thermal stability of ionic compounds

    DEFF Research Database (Denmark)

    2013-01-01

    This invention relates to a method for enhancing the thermal stability of ionic compounds including ionic liquids, by immobilization on porous solid support materials having a pore diameter of between about 20-200 AA, wherein the solid support does not have a pore size of 90 AA.......This invention relates to a method for enhancing the thermal stability of ionic compounds including ionic liquids, by immobilization on porous solid support materials having a pore diameter of between about 20-200 AA, wherein the solid support does not have a pore size of 90 AA....

  11. An Optimal Power Flow (OPF) Method with Improved Power System Stability

    DEFF Research Database (Denmark)

    Su, Chi; Chen, Zhe

    2010-01-01

    This paper proposes an optimal power flow (OPF) method taking into account small signal stability as additional constraints. Particle swarm optimization (PSO) algorithm is adopted to realize the OPF process. The method is programmed in MATLAB and implemented to a nine-bus test power system which ...

  12. A VALIDATED STABILITY INDICATED RP-HPLC METHOD FOR DUTASTERIDE

    OpenAIRE

    D. Pavan Kumar a, b *, Naga Jhansi a, G. Srinivasa Rao b, Kirti Kumar Jain a

    2018-01-01

    ABSTRACT A Simple, Stability indicating, Isocratic, reverse phase High Performance Liquid Chromatographic (RPLC) related substance method was developed for Dutasteride in API. This method separates the impurities which are co-eluting in the pharmacopeia method. Successful separation of degradation impurities and synthetic impurities was achieved by YMC Triat phenyl column. Chromatographic was carried out on YMC Triat phenyl (150 X 4.6 mm, 3.0µm) column using 0.01M Potassium Dihydrogen Pho...

  13. Assessment of the Prony's method for BWR stability analysis

    International Nuclear Information System (INIS)

    Ortiz-Villafuerte, Javier; Castillo-Duran, Rogelio; Palacios-Hernandez, Javier C.

    2011-01-01

    Highlights: → This paper describes a method to determine the degree of stability of a BWR. → Performance comparison between Prony's and common AR techniques is presented. → Benchmark data and actual BWR transient data are used for comparison. → DR and f results are presented and discussed. → The Prony's method is shown to be a robust technique for BWR stability. - Abstract: It is known that Boiling Water Reactors are susceptible to present power oscillations in regions of high power and low coolant flow, in the power-flow operational map. It is possible to fall in one of such instability regions during reactor startup, since both power and coolant flow are being increased but not proportionally. One other possibility for falling into those areas is the occurrence of a trip of recirculation pumps. Stability monitoring in such cases can be difficult, because the amount or quality of power signal data required for calculation of the stability key parameters may not be enough to provide reliable results in an adequate time range. In this work, the Prony's Method is presented as one complementary alternative to determine the degree of stability of a BWR, through time series data. This analysis method can provide information about decay ratio and oscillation frequency from power signals obtained during transient events. However, so far not many applications in Boiling Water Reactors operation have been reported and supported to establish the scope of using such analysis for actual transient events. This work presents first a comparison of decay ratio and frequency oscillation results obtained by Prony's method and those results obtained by the participants of the Forsmark 1 and 2 Boiling Water Reactor Stability Benchmark using diverse techniques. Then, a comparison of decay ratio and frequency oscillation results is performed for four real BWR transient event data, using Prony's method and two other techniques based on an autoregressive modeling. The four

  14. Automatic Testing with Formal Methods

    NARCIS (Netherlands)

    Tretmans, G.J.; Belinfante, Axel

    1999-01-01

    The use of formal system specifications makes it possible to automate the derivation of test cases from specifications. This allows to automate the whole testing process, not only the test execution part of it. This paper presents the state of the art and future perspectives in testing based on

  15. Comparing core stability and traditional trunk exercise on chronic low back pain patients using three functional lumbopelvic stability tests.

    Science.gov (United States)

    Shamsi, Mohammad Bagher; Sarrafzadeh, Javad; Jamshidi, Aliashraf

    2015-02-01

    It is a matter of controversy whether core stability exercise is preferred to other types of exercise for chronic low back pain. Lumbopelvic stability is an important element in low back pain. No study was found using lumbopelvic stability tests in comparing core stability and other exercises. The single leg squat, dip test, and runner pose test appear to be suitable as tests for lumbopelvic stability. The aim of this study was to compare "core stability" and "traditional trunk exercise" using these tests and also the Oswestry disability questionnaire and pain intensity. Twenty-nine non-specific chronic low back pain subjects were alternately allocated in one of the two exercise groups. For both groups, a 16-sessions exercise program was provided. Before and after training: (1) video was recorded while subjects performed the tests; (2) Oswestry disability questionnaire was completed; and (3) pain intensity was measured by visual analogue scale. The test videos were scored by three physiotherapists. Statistical analysis revealed a significant improvement in stability test scores (p = 0.020 and p = 0.041) and reduction in disability (p stability or equal effectiveness of TTE and CSE on improving LPS. The non-significant differences may also be attributable to the lack of sensitivity of our tests to assess stability change in two groups after training given the relatively small sample size.

  16. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2012-01-01

    storage conditions. Methods. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport...... during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under...

  17. Method for rudder roll stabilization control by maintaining ship speed

    Directory of Open Access Journals (Sweden)

    LIU Zhiquan

    2017-01-01

    Full Text Available A ship navigating on the surface of the water may experience greater resistance, adversely affect-ing its speed and leading to energy loss. The added resistance of surface ships in both still water and waves are investigated, and the computation method of total speed loss is presented. An autopilot system is intro-duced to constrain the speed loss, and course keeping and rudder roll stabilization sliding mode control laws are proposed according to a compact control strategy. The two working conditions of "heading" and "heading plus anti-roll" are discussed, including roll stabilization, heading error, speed maintenance and rudder abrasion. The results show that the speed can be effectively maintained using this method, and from a commercial point of view, the fin-rudder roll stabilization control is not recommended for vessels equipped with both fins and rudders.

  18. Dense Output for Strong Stability Preserving Runge–Kutta Methods

    KAUST Repository

    Ketcheson, David I.

    2016-12-10

    We investigate dense output formulae (also known as continuous extensions) for strong stability preserving (SSP) Runge–Kutta methods. We require that the dense output formula also possess the SSP property, ideally under the same step-size restriction as the method itself. A general recipe for first-order SSP dense output formulae for SSP methods is given, and second-order dense output formulae for several optimal SSP methods are developed. It is shown that SSP dense output formulae of order three and higher do not exist, and that in any method possessing a second-order SSP dense output, the coefficient matrix A has a zero row.

  19. "A Comparison of Several Methods in a Rock Slope Stability ...

    African Journals Online (AJOL)

    This researchuses the mentioned methods and principles in the stability analysis of some rock slopes in an open pit mine in Syria, that is Khneifees phosphate mine. The importance of this researchis that it shows the role of kinematical analysis in minimizing efforts when verifying the safety of rock slopes in site, and when ...

  20. Stability estimates for hp spectral element methods for general ...

    Indian Academy of Sciences (India)

    We establish basic stability estimates for a non-conforming ℎ- spectral element method which allows for simultaneous mesh refinement and variable polynomial degree. The spectral element functions are non-conforming if the boundary conditions are Dirichlet. For problems with mixed boundary conditions they are ...

  1. Methods and means for controlling the stability of proteins

    NARCIS (Netherlands)

    Mrabet, Nadir; Lasters, Ignace; Stanssens, Patrick; Matthyssens, Gaston; Wodak, Shoshana; Quax, Wim

    1994-01-01

    The invention pertains to a method for the production of a biologically active modified protein derived from a starting protein having essentially the same kind of biological activity with an attendant modulation effect on, particularly increase of, the stability as compared with that of the

  2. Telemetry test methods. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.; Bullard, D.L.; Schelp, T.R.

    1978-04-01

    A flexible test system is studied and proposed to provide an extensive evaluation and testing capability for telemetry products. A distributed computer controlled, modular unit test system using Computer Automated Measurement and Control (CAMAC) standard hardware and compatible software is selected because of its flexibility of application and long term cost effectiveness.

  3. Stabilizing constrained chaotic system using a symplectic psuedospectral method

    Science.gov (United States)

    Peng, Haijun; Wang, Xinwei; Shi, Boyang; Zhang, Sheng; Chen, Biaosong

    2018-03-01

    The problem of controlling chaotic systems has drawn much attention in the last two decades. However, the controlled system may be subjected to complicated constraints and few researches on controlling chaos take constraints into consideration. Therefore, the stabilization of constrained chaotic system is solved under the frame of nonlinear optimal control in this paper. A symplectic pseudospectral method based on qusilinearizaiton techniques and the parametric variational principle is developed to solve constrained nonlinear optimal control problems with arbitrary Lagrange-type cost functional. At the beginning of the proposed method, the original nonlinear optimal control problem is converted into a series of linear-quadratic constrained optimal control problems. Then each of the converted linear quadratic problems is transformed into a standard linear complementarity problem. The proposed method is successfully applied to stabilizing constrained chaotic systems around an unstable equilibrium point or an unstable periodic orbit. Numerical simulations demonstrate that the developed method is effective and efficient, and constraints are strictly satisfied.

  4. Walking Stabilization Control Using Virtual Plane Method for Biped Robots

    Science.gov (United States)

    Sato, Tomoya; Sakaino, Sho; Ohnishi, Kouhei

    In this paper, a method for walking stabilization control using a virtual plane method for up-down motion of biped robots is proposed. In the case of the up-down motion in whitch the height of the center of gravity (COG) is not constant, the Zero-Moment Point (ZMP) equation that shows the relation between the ZMP and the COG becomes linear time-variant. Using the proposed method, the ZMP equation is transformed into linear time-invariant. Therefore, the frequency analysis and parameter design of the walking stabilization control can be implemented easily even in the up-down motion. The validity of the proposed method was confirmed by some simulations and experiments.

  5. Strong Stability Preserving Two-step Runge–Kutta Methods

    KAUST Repository

    Ketcheson, David I.

    2011-12-22

    We investigate the strong stability preserving (SSP) property of two-step Runge–Kutta (TSRK) methods. We prove that all SSP TSRK methods belong to a particularly simple subclass of TSRK methods, in which stages from the previous step are not used. We derive simple order conditions for this subclass. Whereas explicit SSP Runge–Kutta methods have order at most four, we prove that explicit SSP TSRK methods have order at most eight. We present explicit TSRK methods of up to eighth order that were found by numerical search. These methods have larger SSP coefficients than any known methods of the same order of accuracy and may be implemented in a form with relatively modest storage requirements. The usefulness of the TSRK methods is demonstrated through numerical examples, including integration of very high order weighted essentially non-oscillatory discretizations.

  6. Stabilization/Solidification Remediation Method for Contaminated Soil: A Review

    Science.gov (United States)

    Tajudin, S. A. A.; Azmi, M. A. M.; Nabila, A. T. A.

    2016-07-01

    Stabilization/Solidification (S/S) is typically a process that involves a mixing of waste with binders to reduce the volume of contaminant leachability by means of physical and chemical characteristics to convert waste in the environment that goes to landfill or others possibly channels. Stabilization is attempts to reduce the solubility or chemical reactivity of the waste by changing the physical and chemical properties. While, solidification attempt to convert the waste into easily handled solids with low hazardous level. These two processes are often discussed together since they have a similar purpose of improvement than containment of potential pollutants in treated wastes. The primary objective of this review is to investigate the materials used as a binder in Stabilization/Solidification (S/S) method as well as the ability of these binders to remediate the contaminated soils especially by heavy metals.

  7. Power System Transient Stability Analysis through a Homotopy Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shaobu; Du, Pengwei; Zhou, Ning

    2014-04-01

    As an important function of energy management systems (EMSs), online contingency analysis plays an important role in providing power system security warnings of instability. At present, N-1 contingency analysis still relies on time-consuming numerical integration. To save computational cost, the paper proposes a quasi-analytical method to evaluate transient stability through time domain periodic solutions’ frequency sensitivities against initial values. First, dynamic systems described in classical models are modified into damping free systems whose solutions are either periodic or expanded (non-convergent). Second, because the sensitivities experience sharp changes when periodic solutions vanish and turn into expanded solutions, transient stability is assessed using the sensitivity. Third, homotopy analysis is introduced to extract frequency information and evaluate the sensitivities only from initial values so that time consuming numerical integration is avoided. Finally, a simple case is presented to demonstrate application of the proposed method, and simulation results show that the proposed method is promising.

  8. Testing the stability of travel expenditures in Nigeria

    International Nuclear Information System (INIS)

    Osula, D.O.A.; Adebisi, O.

    2001-01-01

    A report is presented on a study carried out to develop a functional form for travel money expenditure in a Nigerian setting, and test its stability against energy policy change, specifically the fuel price increase of October 1994. The Box-Cox transformation regression approach was adopted in the modelling exercise in order to evolve a data-defined functional form and ensure a more rational basis for the stability test. The results of the modelling exercise show that while statistically significant functional forms were estimated for the 'before' and 'after' fuel price increase periods, the functional forms estimated are not stable across the periods. Thus 'travel budget' is as yet not usable as a term for travel expenditures in Nigeria. The implication of this for travel demand modelling in Nigeria is that, at least till other evidences prove otherwise, there is as yet no basis for using the 'Universal Mechanism of Travel' model developed by Zahavi (The UMOT Project. Report No. DOT-RSPA-DPB-20-79-3; The UMOT Travel Model II Report No. DOT-RSPA-DPB-50-82-11). Of disposable income and total expenditure, the former has proved to be more appropriate for use as 'available money' for the estimation of travel expenditures in Nigeria in the 'before' energy policy change period, while total expenditure proved appropriate in the 'after' period. (author)

  9. Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Andrews, Richard [Fermilab; Carlson, Kermit [Fermilab; Leibfritz, Jerry [Fermilab; Nobrega, Lucy [Fermilab; Valishev, Alexander [Fermilab

    2016-07-01

    The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

  10. Stability of puppy reaction to traditional puppy aptitude test under experimentally reared condtions

    OpenAIRE

    Ishikawa, Keisuke; Eguchi, Yusuke; Uetake, Katsuji; Tnaka, Toshio

    2010-01-01

    The puppy aptitude test (PAT) is a general method for choosing a puppy. However, the reliability of the test has been in doubt because of its lack of a scientific base. In this report, we conducted PAT and some other behavioral tests before and after the establishment of socialization in order to investigate the stability of behavioral traits of puppies. Ten puppies were tested of eleven items on PAT at 57 and 140 days of age. The puppy’s behavior was videotaped and rated by four people using...

  11. Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Groza, Voicu; Isleifsson, Fridrik Rafn

    2012-01-01

    Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads......Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads...

  12. Very high stability systems: LMJ target alignment system and MTG imager test setup

    Science.gov (United States)

    Compain, Eric; Maquet, Philippe; Kunc, Thierry; Marque, Julien; Lauer-Solelhac, Maxime; Delage, Laurent; Lanternier, Catherine

    2015-09-01

    Most of space instruments and research facilities require test equipment with demanding opto-mechanical stability. In some specific cases, when the stability performance directly drives the final performance of the scientific mission and when feasibility is questionable, specific methods must be implemented for the associated technical risk management. In present paper, we will present our heritage in terms of methodology, design, test and the associated results for two specific systems : the SOPAC-POS and the MOTA, generating new references for future developments. From a performance point of view, we will emphasis on following key parameters : design symmetry, thermal load management, and material and structural choices. From a method point of view the difficulties arise first during design, from the strong coupling between the thermal, mechanical and optical performance models, and then during testing, from the difficulty of conceiving test setup having appropriate performance level. We will present how these limitations have been overcome. SOPAC-POS is the target alignment system of the LMJ, Laser Mega Joule, the French inertial confinement fusion research center. Its stability has been demonstrated by tests in 2014 after 10 years of research and development activities, achieving 1μm stability @ 6m during one hour periods. MOTA is an Optical Ground Support Equipment aiming at qualifying by tests the Flexible Combined Imager (FCI). FCI is an instrument for the meteorological satellite MTG-I, a program of and funded by the European Space Agency and under prime contractorship of Thales Alenia Space. Optimized design will allow to get better than 0.2 μrad stability for one hour periods, as required for MTF measurement.

  13. Postural stability in patients with decompression sickness evaluated by means of Quantitative Romberg testing

    DEFF Research Database (Denmark)

    Hedetoft, Morten; Hyldegaard, Ole

    2015-01-01

    OBJECTIVE: The present study was designed to retrospectively evaluate the use of quantitative Romberg's testing on postural stability during the course of hyperbaric oxygen (HBO2) therapy in patients presenting with decompression sickness (DCS). METHODS: The Quantitative Romberg test was used...... obtained with the Quantitative Romberg test were observed in the group of DCS with vertigo relative to DCS without vertigo and healthy controls. A stepwise improvement in postural instability for DCS patients with vertigo was found following HBO2 therapy. After three treatments of HBO2, postural stability...... was found to be within the normal range of healthy controls. CONCLUSIONS: The Quantitative Romberg test offers the the clinician a fast, reliable and objective set of parametrical data to document postural instability in patients with either confirmed or suspected DCS....

  14. Electromechanical impedance method to assess dental implant stability

    International Nuclear Information System (INIS)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W

    2012-01-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone–implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare ® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant–bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity. (paper)

  15. Electromechanical impedance method to assess dental implant stability

    Science.gov (United States)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W.

    2012-11-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone-implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant-bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity.

  16. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  17. Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test.

    Science.gov (United States)

    Gilbert, Hunter B; Hendrick, Richard J; Webster, Robert J

    2016-02-01

    Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for how stable a given robot configuration is has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e. whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.

  18. Evaluation of mid-term stability of night vision tests.

    Science.gov (United States)

    Levy, Y; Glovinsky, Y

    1997-07-01

    Dark adaptation rate, scotopic retinal sensitivity and contrast sensitivity under mesopic conditions, but not visual acuity, have been shown to be directly related to the ability to identify military targets at night. These parameters can be used to select personnel for specific military tasks demanding excellent night vision, as well as to assess pharmacological effects on night vision. To evaluate the mid-term (2 to 6-week period) stability of night vision tests based on assessment of the above parameters. Dark adaptation rate, scotopic retinal sensitivity and contrast sensitivity under mesopic conditions were studied in 16 young volunteers during a 6-week period. Tests of scotopic retinal sensitivity (after 30 min of dark adaptation) exhibited high reproducibility and a low fluctuation rate, with a high correlation between values at week 0 and at 2-week intervals during the following 6 weeks of the study (rs (week 0 to week 6) = 0.81, p = 0.0001). The reproducibility of mesopic contrast sensitivity tests (average of 1.5, 3, 6 and 12 cycles per degree, (cpd)) was fair (rs (week 0 to week 2) = 0.67, p = 0.0045), whereas that of dark adaptation rate tests was poor. In view of the reproducibility characteristics of these night vision tests, assessment of night vision ability in pilots and military personnel, as well as assessment of pharmacological effects on night vision, may be based on scotopic retinal sensitivity (after 30 min of dark adaptation) and contrast sensitivity under mesopic conditions (average of 1.5, 3, 6 and 12 cpd).

  19. Flatworm models in pharmacological research: the importance of compound stability testing.

    Science.gov (United States)

    Stalmans, Sofie; Willems, Maxime; Adriaens, Els; Remon, Jean-Paul; D'Hondt, Matthias; De Spiegeleer, Bart

    2014-10-01

    Flatworms possess adult pluripotent stem cells, which make them extraordinary experimental model organisms to assess in vivo the undesirable effects of substances on stem cells. Currently, quality practices, implying evaluation of the stability of the test compound under the proposed experimental conditions, are uncommon in this research field. Nevertheless, performing a stability study during the rational design of in vivo assay protocols will result in more reliable assay results. To illustrate the influence of the stability of the test substance on the final experimental outcome, we performed a short-term International Conference on Harmonization (ICH)-based stability study of cyclophosphamide in the culture medium, to which a marine flatworm model Macrostomum lignano is exposed. Using a validated U(H)PLC method, it was demonstrated that the cyclophosphamide concentration in the culture medium at 20°C is lowered to 80% of the initial concentration after 21days. The multiwell plates, flatworms and diatoms, as well as light exposure, did not influence significantly the cyclophosphamide concentration in the medium. The results of the stability study have practical implications on the experimental set-up of the carcinogenicity assay like the frequency of medium renewal. This case study demonstrates the benefits of applying appropriate quality guidelines already during fundamental research increasing the credibility of the results. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  1. Stability testing of vaccines: Developing Countries Vaccine Manufacturers' Network (DCVMN) perspective.

    Science.gov (United States)

    Jadhav, Suresh S; Dogar, Vikas; Gautam, Manish; Gairola, Sunil

    2009-11-01

    Stability testing is an integral part of the vaccine manufacturing process and is crucial for the success of immunization programs. WHO (World Health Organization) has recently published guidelines on the stability testing of vaccines. These guidelines enlist scientific basis and principles for stability testing at various stages like development, pre-clinical, clinical, licensing, lot release and post-licensure monitoring. DCVMN (Developing Countries Vaccine Manufacturers' Network) is an international body of developing countries vaccine manufacturers and has viewpoints on technical and administrative issues in stability testing of vaccines. We here highlight viewpoints, possible roles and global expectations of DCVMN in the area of stability testing of vaccines.

  2. Data Fusion Modeling for an RT3102 and Dewetron System Application in Hybrid Vehicle Stability Testing

    Directory of Open Access Journals (Sweden)

    Zhibin Miao

    2015-08-01

    Full Text Available More and more hybrid electric vehicles are driven since they offer such advantages as energy savings and better active safety performance. Hybrid vehicles have two or more power driving systems and frequently switch working condition, so controlling stability is very important. In this work, a two-stage Kalman algorithm method is used to fuse data in hybrid vehicle stability testing. First, the RT3102 navigation system and Dewetron system are introduced. Second, a modeling of data fusion is proposed based on the Kalman filter. Then, this modeling is simulated and tested on a sample vehicle, using Carsim and Simulink software to test the results. The results showed the merits of this modeling.

  3. Methods to assess the stability of a bicycle rider system

    NARCIS (Netherlands)

    Cooke, A.G.; Bulsink, Vera Elisabeth; Beusenberg, Mark; Dubbeldam, Rosemary; Bonnema, Gerrit Maarten; Poelman, Wim; Koopman, Hubertus F.J.M.

    2012-01-01

    The SOFIE (Intelligent Assisted Bicycles) project wishes to create performance and design guidelines for mechatronic appliances which improve the stability of electric bicycles, so-called intelligent stability assist devices (IAD). To achieve this goal, a stability hypothesis, an advanced

  4. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  5. Draft environmental assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  6. Environmental Assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-08-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped from the EA/FONSI issued May 6, 1996. A new drying process was subsequently developed and is analyzed in Section 2.1.2 of this document. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  7. Environmental Assessment -- Test Area North pool stabilization project update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    The purpose of this Environmental Assessment (EA) is to update the ``Test Area North Pool Stabilization Project`` EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped from the EA/FONSI issued May 6, 1996. A new drying process was subsequently developed and is analyzed in Section 2.1.2 of this document. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN.

  8. Draft environmental assessment -- Test Area North pool stabilization project update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ``Test Area North Pool Stabilization Project`` EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN.

  9. Transient and stability tests at Peach Bottom Atomic Power Station Unit 2 at end of Cycle 2

    International Nuclear Information System (INIS)

    Carmichael, L.A.; Niemi, R.O.

    1978-06-01

    Turbine trip transient and low flow stability tests were performed at the Peach Bottom-2 BWR/4 nuclear power plant prior to shutdown for refueling at end of Cycle 2 in April 1977. The results of the turbine trip transient tests showed that the fundamental mode of the acoustical pressure oscillation generated in the main steam piping propagates with relatively little attenuation into the reactor core. The magnitude of the neutron flux transient taking place in the BWR core was found to be strongly affected by the initial rate of pressure rise caused by the pressure oscillation. The measured neutron flux transients showed a strong spatial variation along the axis of the reactor core. Very little radial variation in the neutron flux transient was observed. The low-flow stability tests demonstrated that the Peach Bottom-2 Cycle 2 core exhibited a high degree of stability at the limiting test condition above the rated power-flow control line. The measured reactor stability margins showed the expected sensitivity to core power changes at minimum reactor core flow. The tests showed that the small pressure perturbation stability testing offers a useful and practical method of measuring core stability margins. The actual core stability margin was determined from the measured closed-loop pressure to average neutron flux transfer function data based on maximum likelihood estimates of the parameters in a relatively simple transfer function model determined from nonlinear regression analysis. Both static and dynamic error estimates were taken into consideration in evaluating the test results

  10. The WST method, a fracture mechanics test method for FRC

    DEFF Research Database (Denmark)

    Lofgren, I.; Stang, Henrik; Olesen, John Forbes

    2008-01-01

    The applicability of the wedge-splitting test method (WST), for determining fracture properties of fibre-reinforced concrete, is discussed. Experimental results, using the WST method, are compared with results from uniaxial tension tests (UTT) and three-point bending tests (3PBT) for five differe...

  11. Deformation Monitoring of Geomechanical Model Test and Its Application in Overall Stability Analysis of a High Arch Dam

    Directory of Open Access Journals (Sweden)

    Baoquan Yang

    2015-01-01

    Full Text Available Geomechanical model testing is an important method for studying the overall stability of high arch dams. The main task of a geomechanical model test is deformation monitoring. Currently, many types of deformation instruments are used for deformation monitoring of dam models, which provide valuable information on the deformation characteristics of the prototype dams. However, further investigation is required for assessing the overall stability of high arch dams through analyzing deformation monitoring data. First, a relationship for assessing the stability of dams is established based on the comprehensive model test method. Second, a stability evaluation system is presented based on the deformation monitoring data, together with the relationships between the deformation and overloading coefficient. Finally, the comprehensive model test method is applied to study the overall stability of the Jinping-I high arch dam. A three-dimensional destructive test of the geomechanical model dam is conducted under reinforced foundation conditions. The deformation characteristics and failure mechanisms of the dam abutments and foundation were investigated. The test results indicate that the stability safety factors of the dam abutments and foundation range from 5.2 to 6.0. These research results provide an important scientific insight into the design, construction, and operation stages of this project.

  12. Stability studies on florfenicol using developed derivative spectrophotometric methods.

    Science.gov (United States)

    Elimam, M M; Shantier, S W; Gadkariem, E A; Mohamed, M A; Osman, Z

    2017-01-01

    This study aims to investigate the stability of florfenicol using previously developed derivative spectrophotometric methods (D 1 and D 2 ). The studied stability-indicating pararmeters included alkali (NaOH, 1M), acid (HCl, 1M), pH changes (buffer pH 2.2-11), temperature (80°C and 100°C at pH 10) and light. A constructed pH profile for the drug degradation rate revealed a significant effect of pH on the drug stability between pH ranges 8 and 11. The obtained profile indicated first order dependence of K obs on [OH - ]. Arrhenius plot at pH 10 was found linear at temperatures 80°C and 100°C with estimated activation energy of 19.35kcal/mol. The calculated rate constant (K obs ), t ½ and t 90 at 25°C were found to be 1.8×10 -3 h, 385h and 58.3h, respectively. The photostability of florfenicol was also studied by exposing the drug solution to direct sunlight during mid-day time. The obtained results reflected the instability of florfenicol under the study conditions. Copyright © 2016 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  13. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    to the test method were suggested. A digital stirring and control system, and a method for determining the mean air pressure difference, as well as a method for testing barriers with a very low air infiltration, were provided. The digital stirring and control system ensured automatic control and measuring...

  14. Purohit's spectrophotometric method for determination of stability constants of complexes using Job's curves

    International Nuclear Information System (INIS)

    Purohit, D.N.; Goswami, A.K.; Chauhan, R.S.; Ressalan, S.

    1999-01-01

    A spectrophotometric method for determination of stability constants making use of Job's curves has been developed. Using this method stability constants of Zn(II), Cd(II), Mo(VI) and V(V) complexes of hydroxytriazenes have been determined. For the sake of comparison, values of the stability constants were also determined using Harvey and Manning's method. The values of the stability constants developed by two methods compare well. This new method has been named as Purohit's method. (author)

  15. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  16. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges.

    Science.gov (United States)

    Prest, Emmanuelle I; Hammes, Frederik; van Loosdrecht, Mark C M; Vrouwenvelder, Johannes S

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  17. Biological stability of drinking water: controlling factors, methods and challenges

    Directory of Open Access Journals (Sweden)

    Emmanuelle ePrest

    2016-02-01

    Full Text Available Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g. development of opportunistic pathogens, aesthetic (e.g. deterioration of taste, odour, colour or operational (e.g. fouling or biocorrosion of pipes problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors such as (i type and concentration of available organic and inorganic nutrients, (ii type and concentration of residual disinfectant, (iii presence of predators such as protozoa and invertebrates, (iv environmental conditions such as water temperature, and (v spatial location of microorganisms (bulk water, sediment or biofilm. Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i existing knowledge on biological stability controlling factors and (ii how these factors are affected by drinking water production and distribution conditions. In addition, (iii the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discuss how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to

  18. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    KAUST Repository

    Prest, Emmanuelle I.

    2016-02-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  19. Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges

    Science.gov (United States)

    Prest, Emmanuelle I.; Hammes, Frederik; van Loosdrecht, Mark C. M.; Vrouwenvelder, Johannes S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order

  20. A method for studying stability domains in physical models

    Science.gov (United States)

    Gallas, Jason A. C.

    1994-10-01

    We present a method for investigating the simultaneous movement of all zeros of equations of motions defined by discrete mappings. The method is used to show that knowledge of the interplay of all zeros is of fundamental importance for establishing periodicities and relative stability properties of the various possible physical solutions. The method is also used (i) to show that the Frontière set of Fatou is defined primarily by zeros of functions leading to an entire invariant limiting function which underlies every dynamical system, (ii) to identify cyclotomic polynomials as components of the limiting function obtained for a parameter value supporting a particular superstable orbit of the quadratic map, (iii) to describe highly symmetric periodic cycles embedded in these components, and (iv) to provide an unified picture about which mathematical objects form basin boundaries of dynamical systems in general: the closure of all zeros not belonging to “stable” orbits.

  1. The effect of walking speed on local dynamic stability is sensitive to calculation methods

    DEFF Research Database (Denmark)

    Stenum, Jan; Bruijn, Sjoerd M; Jensen, Bente Rona

    2014-01-01

    Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been...... reported. This might pertain to methodological differences in calculating λS. Therefore, the aim was to test if different calculation methods would induce different effects of walking speed on local dynamic stability. Ten young healthy participants walked on a treadmill at five speeds (60%, 80%, 100%, 120......% and 140% of preferred walking speed) for 3min each, while upper body accelerations in three directions were sampled. From these time-series, λS was calculated by three different methods using: (a) a fixed time interval and expressed as logarithmic divergence per stride-time (λS-a), (b) a fixed number...

  2. Stability Analysis of Numerical Methods for a 1.5-Layer Shallow-Water Ocean Model

    Directory of Open Access Journals (Sweden)

    Guang-an Zou

    2013-01-01

    Full Text Available A 1.5-layer reduced-gravity shallow-water ocean model in spherical coordinates is described and discretized in a staggered grid (standard Arakawa C-grid with the forward-time central-space (FTCS method and the Leap-frog finite difference scheme. The discrete Fourier analysis method combined with the Gershgorin circle theorem is used to study the stability of these two finite difference numerical models. A series of necessary conditions of selection criteria for the time-space step sizes and model parameters are obtained. It is showed that these stability conditions are more accurate than the Courant-Friedrichs-Lewy (CFL condition and other two criterions (Blumberg and Mellor, 1987; Casulli, 1990, 1992. Numerical experiments are proposed to test our stability results, and numerical model that is designed is also used to simulate the ocean current.

  3. Feedback module for evaluating optical-power stabilization methods

    Science.gov (United States)

    Downing, John

    2016-03-01

    A feedback module for evaluating the efficacy of optical-power stabilization without thermoelectric coolers (TECs) is described. The module comprises a pickoff optic for sampling a light beam, a photodiode for converting the sample power to electrical current, and a temperature sensor. The components are mounted on an optical bench that makes accurate (0.05°) beam alignment practical as well as providing high thermal-conductivity among the components. The module can be mounted on existing light sources or the components can be incorporated in new designs. Evaluations of optical and electronic stabilization methods are also reported. The optical method combines a novel, weakly reflective, weakly polarizing coating on the pickoff optic with a photodiode and an automatic-power-control (APC) circuit in a closed loop. The shift of emitter wavelength with temperature, coupled with the wavelength-dependent reflectance of the pickoff optic, enable the APC circuit to compensate for temperature errors. In the electronic method, a mixed-signal processor in a quasiclosed loop generates a control signal from temperature and photocurrent inputs and feeds it back to an APC circuit to compensate for temperature errors. These methods result in temperature coefficients less than 20 ppm/°C and relative rms power equal to 05% for the optical method and 0.02% for the electronic method. The later value represents an order of magnitude improvement over rms specifications for cooled, laser-diode modules and a five-fold improvement in wall-plug efficiency is achieved by eliminating TECs.

  4. Standard Testing Methods for Satellite Communication Systems

    OpenAIRE

    Stoner, Jerry

    2005-01-01

    University space programs continue to push the envelope of small satellite technology. Because budgets are often limited, and equipment costs can often be prohibitive to even well-established space programs, it becomes necessary to maximize the benefit/cost ratio of testing methods. Expensive testing is often not an option, nor is it realistic. Traditional methods such as anechoic chambers or antenna test ranges are not options, and testing the craft on the ground is not practical. Because of...

  5. T-Stability of the Heun Method and Balanced Method for Solving Stochastic Differential Delay Equations

    Directory of Open Access Journals (Sweden)

    Xiaolin Zhu

    2014-01-01

    Full Text Available This paper studies the T-stability of the Heun method and balanced method for solving stochastic differential delay equations (SDDEs. Two T-stable conditions of the Heun method are obtained for two kinds of linear SDDEs. Moreover, two conditions under which the balanced method is T-stable are obtained for two kinds of linear SDDEs. Some numerical examples verify the theoretical results proposed.

  6. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  7. Method of stabilizing a laser apparatus with wavelength converter

    DEFF Research Database (Denmark)

    2013-01-01

    A method of controlling beam quality and stability of a laser apparatus, the laser apparatus comprising, a diode laser (10) providing first radiation of at least a first wavelength, and a frequency conversion unit (12) configured to frequency-convert the first radiation from the diode laser......) into the first section (222), a second contact (221) for injecting a second current (I2) into the second section (223), and means for controlling a temperature of the diode laser; wherein the method comprises monitoring a first parameter indicative of the power content of a dominant lobe of the first radiation...... and to output the frequency-converted radiation (213), the frequency-converted radiation having at least a second wavelength different from the first wavelength, the diode laser (10) comprising at least a first and a second section (222,223), a first contact (220) for injecting a first current (I1...

  8. Flight Test Experiment Design for Characterizing Stability and Control of Hypersonic Vehicles

    Science.gov (United States)

    Morelli, Eugene A.

    2008-01-01

    A maneuver design method that is particularly well-suited for determining the stability and control characteristics of hypersonic vehicles is described in detail. Analytical properties of the maneuver design are explained. The importance of these analytical properties for maximizing information content in flight data is discussed, along with practical implementation issues. Results from flight tests of the X-43A hypersonic research vehicle (also called Hyper-X) are used to demonstrate the excellent modeling results obtained using this maneuver design approach. A detailed design procedure for generating the maneuvers is given to allow application to other flight test programs.

  9. Stability-indicating HPLC method for the determination of the stability of oxytocin parenteral solutions prepared in polyolefin bags.

    Science.gov (United States)

    Kaushal, G; Sayre, B E; Prettyman, T

    2012-02-01

    Oxytocin is very commonly used in clinical settings and is a nonapeptide hormone that stimulates the contraction of uterine smooth muscles. In this study the stability of extemporaneously compounded oxytocin solutions was investigated in polyolefin bags. The sterile preparations of oxytocin were compounded to the strength of 0.02 U/mL in accordance with United States Pharmacopeia (USP) standards. In order to carry out the stability testing of these parenteral products, the solutions were stored under three different temperature conditions of -20°C (frozen), 2-6°C (refrigerated), and 22-25°C (room temperature). Three solutions from each temperature were withdrawn and were assessed for stability on days 0, 7, 15, 21, and 30 as per the USP guidelines. The assay of oxytocin was examined by an HPLC method at each time point. No precipitation, cloudiness or color change was observed during this study at all temperatures. The assay content by HPLC revealed that oxytocin retains greater than at least 90% of the initial concentrations for 21 days. There was no significant change in pH and absorbance values for 21 days under all the conditions of storage. Oxytocin parenteral solutions in the final concentration of 0.02 U/mL and diluted in normal saline are stable for at least 30 days under frozen and refrigerated conditions for 30 days. At the room temperature, the oxytocin solutions were stable for at least 21 days. The stability analysis results show that the shelf-life of 21 days observed in this study was far better than their recommended expiration dates.

  10. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  11. Acid Pit Stabilization Project (Volume 1 - Cold Testing) and (Volume 2 - Hot Testing)

    Energy Technology Data Exchange (ETDEWEB)

    G. G. Loomis (INEEL); A. P. Zdinak (MSE); M. A. Ewanic (MSE); J. J. Jessmore (INEEL)

    1998-01-01

    During the summer and fall of Fiscal Year 1997, a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Treatability Study was performed at the Idaho National Engineering and Environmental Laboratory. The study involved subsurface stabilization of a mixed waste contaminated soil site called the Acid Pit. This study represents the culmination of a successful technology development effort that spanned Fiscal Years 1994-1996. Research and development of the in situ grout stabilization technique was conducted. Hardware and implementation techniques are currently documented in a patent pending with the United States Patent and Trademark Office. The stabilization technique involved using jet grouting of an innovative grouting material to form a monolith out of the contamination zone. The monolith simultaneously provides a barrier to further contaminant migration and closes voids in the soil structure against further subsidence. This is accomplished by chemical incorporation of contaminants into less soluble species and achieving a general reduction in hydraulic conductivity within the monolith. The grout used for this study was TECT-HG, a relatively dense iron oxide-based cementitious grout. The treatability study involved cold testing followed by in situ stabilization of the Acid Pit. Volume 1 of this report discusses cold testing, performed as part of a ''Management Readiness Assessment'' in preparation for going hot. Volume 2 discusses the results of the hot Acid Pit Stabilization phase of this project. Drilling equipment was specifically rigged to reduce the spread of contamination, and all grouting was performed under a concrete block containing void space to absorb any grout returns. Data evaluation included examination of implementability of the grouting process and an evaluation of the contaminant spread during grouting. Following curing of the stabilized pit, cores were obtained and evaluated for toxicity

  12. On the use of voltammetric methods to determine electrochemical stability limits for lithium battery electrolytes

    Science.gov (United States)

    Georén, Peter; Lindbergh, Göran

    In previous studies a novel amphiphilic co-polymer was developed for use in lithium-ion batteries. In order to evaluate the electrochemical stability of that electrolyte and compare it with others, a voltammetric method was applied on a set of electrolytes with different salts, solvents and polymers. However, initially the voltammetric methodology was studied. Platinum was found to be the most suited electrode material, experiencing no significant interfering reactions and a proper diffusion-controlled kinetic behaviour when sweep rate was varied. Furthermore, the influence on the voltammograms of adding water traces to the electrolytes was studied. It could be established that the oxidation peak around 3.8 V versus Li was related to water reactions. It was concluded that quantitative voltage values of the stability limits were difficult to assess using voltammetry. On the other hand, the method seemed well suited for comparison of electrolytes and to investigate the influences of electrolyte components on the stability. The voltammetric results varied little between the different electrolytes evaluated and the anodic and cathodic limits, as defined here, were in the range of 1 and 4.5 V vs. Li, respectively. Although the novel polymer did not affect the stability limit significantly it seemed to promote the breakdown reaction rate in all electrolytes tested. Furthermore, the use of LiTFSI salt reduced the stability window.

  13. HDMR methods to assess reliability in slope stability analyses

    Science.gov (United States)

    Kozubal, Janusz; Pula, Wojciech; Vessia, Giovanna

    2014-05-01

    Stability analyses of complex rock-soil deposits shall be tackled considering the complex structure of discontinuities within rock mass and embedded soil layers. These materials are characterized by a high variability in physical and mechanical properties. Thus, to calculate the slope safety factor in stability analyses two issues must be taken into account: 1) the uncertainties related to structural setting of the rock-slope mass and 2) the variability in mechanical properties of soils and rocks. High Dimensional Model Representation (HDMR) (Chowdhury et al. 2009; Chowdhury and Rao 2010) can be used to carry out the reliability index within complex rock-soil slopes when numerous random variables with high coefficient of variations are considered. HDMR implements the inverse reliability analysis, meaning that the unknown design parameters are sought provided that prescribed reliability index values are attained. Such approach uses implicit response functions according to the Response Surface Method (RSM). The simple RSM can be efficiently applied when less than four random variables are considered; as the number of variables increases, the efficiency in reliability index estimation decreases due to the great amount of calculations. Therefore, HDMR method is used to improve the computational accuracy. In this study, the sliding mechanism in Polish Flysch Carpathian Mountains have been studied by means of HDMR. The Southern part of Poland where Carpathian Mountains are placed is characterized by a rather complicated sedimentary pattern of flysh rocky-soil deposits that can be simplified into three main categories: (1) normal flysch, consisting of adjacent sandstone and shale beds of approximately equal thickness, (2) shale flysch, where shale beds are thicker than adjacent sandstone beds, and (3) sandstone flysch, where the opposite holds. Landslides occur in all flysch deposit types thus some configurations of possible unstable settings (within fractured rocky

  14. A Robust Method of Vehicle Stability Accurate Measurement Using GPS and INS

    Directory of Open Access Journals (Sweden)

    Miao Zhibin

    2015-12-01

    Full Text Available With the development of the vehicle industry, controlling stability has become more and more important. Techniques of evaluating vehicle stability are in high demand. Integration of Global Positioning System (GPS and Inertial Navigation System (INS is a very practical method to get high-precision measurement data. Usually, the Kalman filter is used to fuse the data from GPS and INS. In this paper, a robust method is used to measure vehicle sideslip angle and yaw rate, which are two important parameters for vehicle stability. First, a four-wheel vehicle dynamic model is introduced, based on sideslip angle and yaw rate. Second, a double level Kalman filter is established to fuse the data from Global Positioning System and Inertial Navigation System. Then, this method is simulated on a sample vehicle, using Carsim software to test the sideslip angle and yaw rate. Finally, a real experiment is made to verify the advantage of this approach. The experimental results showed the merits of this method of measurement and estimation, and the approach can meet the design requirements of the vehicle stability controller.

  15. Absorbing Software Testing into the Scrum Method

    Science.gov (United States)

    Tuomikoski, Janne; Tervonen, Ilkka

    In this paper we study, how to absorb software testing into the Scrum method. We conducted the research as an action research during the years 2007-2008 with three iterations. The result showed that testing can and even should be absorbed to the Scrum method. The testing team was merged into the Scrum teams. The teams can now deliver better working software in a shorter time, because testing keeps track of the progress of the development. Also the team spirit is higher, because the Scrum team members are committed to the same goal. The biggest change from test manager’s point of view was the organized Product Owner Team. Test manager don’t have testing team anymore, and in the future all the testing tasks have to be assigned through the Product Backlog.

  16. STABILIZATION AND TESTING OF MERCURY CONTAINING WASTES: BORDEN SLUDGE

    Science.gov (United States)

    This report details the stability assessment of a mercury containing sulfide treatment sludge. Information contained in this report will consist of background data submitted by the geneerator, landfill data supplied by EPA and characterization and leaching studies conducted by UC...

  17. Method of waste stabilization with dewatered chemically bonded phosphate ceramics

    Science.gov (United States)

    Wagh, Arun; Maloney, Martin D.

    2010-06-29

    A method of stabilizing a waste in a chemically bonded phosphate ceramic (CBPC). The method consists of preparing a slurry including the waste, water, an oxide binder, and a phosphate binder. The slurry is then allowed to cure to a solid, hydrated CBPC matrix. Next, bound water within the solid, hydrated CBPC matrix is removed. Typically, the bound water is removed by applying heat to the cured CBPC matrix. Preferably, the quantity of heat applied to the cured CBPC matrix is sufficient to drive off water bound within the hydrated CBPC matrix, but not to volatalize other non-water components of the matrix, such as metals and radioactive components. Typically, a temperature range of between 100.degree. C.-200.degree. C. will be sufficient. In another embodiment of the invention wherein the waste and water have been mixed prior to the preparation of the slurry, a select amount of water may be evaporated from the waste and water mixture prior to preparation of the slurry. Another aspect of the invention is a direct anyhydrous CBPC fabrication method wherein water is removed from the slurry by heating and mixing the slurry while allowing the slurry to cure. Additional aspects of the invention are ceramic matrix waste forms prepared by the methods disclosed above.

  18. Conductometric method for determining water stability and nutrient leaching of extruded fish feed

    Directory of Open Access Journals (Sweden)

    Banjac Vojislav V.

    2017-01-01

    Full Text Available Water stability of eight samples of extruded salmon feeds was first determined by applying two gravimetric methods developed by the authors: gravimetric static and wet sieving method. Then, the conductometric method, primarily developed for investigation of nutrient leaching of feed into the water by the authors, was used for each sample. The aim of this study was to evaluate the potential of the conductometric measurement as a technique for determining water stability of extruded fish feed. In order to find any correlation between the results of two gravimetric tests and conductometric method, correlation analysis was employed. The results of static and wet sieving method were expressed as water stability index, which was expressed as the percent of remained dry matter of sample after being disintegrated in the water. The results of conductometric method were shown as conductivity curves for each sample, giving the insight in rate of nutrient leaching during the time. The obtained values of water conductivity showed no significant (p < 0.05 correlation with the results of static water method, while there was a negative significant (p < 0.05 correlation with the results of wet sieving method during first four hours of pellets soaking in water. The highest correlation coefficients were obtained within the first hour of conductivity measurement, demonstrating that proposed conductometric method had a potential to be applied as a rapid and simple method for determination and relative comparison of salmon feed water stability.[ Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. III46012 and Grant no. TR31011

  19. Behavior of Stabilized Peat Soils in Unconfined Compression Tests

    OpenAIRE

    Wong L. Sing; Roslan Hashim; Faisal H. Ali

    2008-01-01

    Problem statement: Deep stabilized peat columns were known to be economical at forming foundations to support highway embankments constructed on deep peat land. However, failure in the formation of the columns with adequate strength was often attributed to unsuitable type and insufficient dosage of binder added to the soil. Organic matter in peat was known to impede the cementing process in the soil, thus retarding the early strength gain of stabilized peat. Approach: To evaluate the strength...

  20. Power meter ratio method of stabilizing a resonant modulator

    Science.gov (United States)

    Lentine, Anthony L.; Cox, Jonathan Albert

    2016-10-11

    Methods and systems for stabilizing a resonant modulator include receiving pre-modulation and post-modulation portions of a carrier signal, determining the average power from these portions, comparing an average input power to the average output power, and operating a heater coupled to the modulator based on the comparison. One system includes a pair of input structures, one or more processing elements, a comparator, and a control element. The input structures are configured to extract pre-modulation and post-modulation portions of a carrier signal. The processing elements are configured to determine average powers from the extracted portions. The comparator is configured to compare the average input power and the average output power. The control element operates a heater coupled to the modulator based on the comparison.

  1. A new method for tear film stability analysis using videokeratography.

    Science.gov (United States)

    Goto, Tomoko; Zheng, Xiaodong; Klyce, Stephen D; Kataoka, Hisashi; Uno, Toshihiko; Karon, Mike; Tatematsu, Yoshiyuki; Bessyo, Takeo; Tsubota, Kazuo; Ohashi, Yuichi

    2003-05-01

    To report a new tear film stability analysis system using videokeratography. Observational case series. New videokeratography software for TMS-2N (topographic modeling system; TOMEY Corporation, Nagoya, Japan) was developed that can automatically capture consecutive corneal surface images every second for 10 seconds. Forty-eight adult volunteers (80 eyes) were recruited for this study, and all subjects were examined with the new system. Corneal topographs were analyzed for tear breakup time (TMS-BUT) and the ratio of breakup area to entire color-code area (TMS-BUA) was calculated. Routine methods for tear film breakup time evaluation using slit-lamp microscope and fluorescence staining (SLE-BUT) were performed for comparison purposes. Regressive correlations of TMS-BUT or TMS-BUA with SLE-BUT were analyzed. Based on SLE results, subjects were separated into two groups with normal and short BUT, respectively. TMS-BUT and TMS-BUA were compared with SLE-BUT data with regard to the sensitivity and specificity of evaluation of dry eye symptoms. Topographic modeling system-tear breakup time (TMS-BUT) had a positive correlation with SLE-BUT (R = 0.7219, P TMS-BUA showed a negative correlation (R = 0.6317, P TMS-BUT, 9 (81.82%) of which were associated with dry eye symptoms. The sensitivities of TMS-BUT and TMS-BUA were 97.5% and 95%, respectively, significantly higher than that of SLE-BUT (75%), with P =.008 and 0.01, respectively. Topographic modeling system-BUT and TMS-BUA displayed a similar rate of specificity in comparison with SLE-BUT. This new videokeratography system is a noninvasive and objective method with increased sensitivity for tear film stability analysis.

  2. Landslide Geohazard Monitoring, Early Warning and Stabilization Control Methods

    Science.gov (United States)

    Bednarczyk, Zbigniew

    2014-03-01

    This paper is a presentation of landslide monitoring, early warning and remediation methods recommended for the Polish Carpathians. Instrumentation included standard and automatic on-line measurements with the real-time transfer of data to an Internet web server. The research was funded through EU Innovative Economy Programme and also by the SOPO Landslide Counteraction Project. The landslides investigated were characterized by relatively low rates of the displacements. These ranged from a few millimetres to several centimetres per year. Colluviums of clayey flysch deposits were of a soil-rock type with a very high plasticity and moisture content. The instrumentation consisted of 23 standard inclinometers set to depths of 5-21 m. The starting point of monitoring measurements was in January 2006. These were performed every 1-2 months over the period of 8 years. The measurements taken detected displacements from several millimetres to 40 cm set at a depth of 1-17 m. The modern, on-line monitoring and early warning system was installed in May 2010. The system is the first of its kind in Poland and only one of several such real-time systems in the world. The installation was working with the Local Road Authority in Gorlice. It contained three automatic field stations for investigation of landslide parameters to depths of 12-16 m and weather station. In-place tilt transducers and innovative 3D continuous inclinometer systems with sensors located every 0.5 m were used. It has the possibility of measuring a much greater range of movements compared to standard systems. The conventional and real-time data obtained provided a better recognition of the triggering parameters and the control of geohazard stabilizations. The monitoring methods chosen supplemented by numerical modelling could lead to more reliable forecasting of such landslides and could thus provide better control and landslide remediation possibilities also to stabilization works which prevent landslides.

  3. Landslide Geohazard Monitoring, Early Warning and Stabilization Control Methods

    Directory of Open Access Journals (Sweden)

    Bednarczyk Zbigniew

    2014-03-01

    Full Text Available This paper is a presentation of landslide monitoring, early warning and remediation methods recommended for the Polish Carpathians. Instrumentation included standard and automatic on-line measurements with the real-time transfer of data to an Internet web server. The research was funded through EU Innovative Economy Programme and also by the SOPO Landslide Counteraction Project. The landslides investigated were characterized by relatively low rates of the displacements. These ranged from a few millimetres to several centimetres per year. Colluviums of clayey flysch deposits were of a soil-rock type with a very high plasticity and moisture content. The instrumentation consisted of 23 standard inclinometers set to depths of 5-21 m. The starting point of monitoring measurements was in January 2006. These were performed every 1-2 months over the period of 8 years. The measurements taken detected displacements from several millimetres to 40 cm set at a depth of 1-17 m. The modern, on-line monitoring and early warning system was installed in May 2010. The system is the first of its kind in Poland and only one of several such real-time systems in the world. The installation was working with the Local Road Authority in Gorlice. It contained three automatic field stations for investigation of landslide parameters to depths of 12-16 m and weather station. In-place tilt transducers and innovative 3D continuous inclinometer systems with sensors located every 0.5 m were used. It has the possibility of measuring a much greater range of movements compared to standard systems. The conventional and real-time data obtained provided a better recognition of the triggering parameters and the control of geohazard stabilizations. The monitoring methods chosen supplemented by numerical modelling could lead to more reliable forecasting of such landslides and could thus provide better control and landslide remediation possibilities also to stabilization works which

  4. Biomechanical testing of a polymer-based biomaterial for the restoration of spinal stability after nucleotomy

    Directory of Open Access Journals (Sweden)

    Kaps Christian

    2009-07-01

    Full Text Available Abstract Background Surgery for disc herniations can be complicated by two major problems: painful degeneration of the spinal segment and re-herniation. Therefore, we examined an absorbable poly-glycolic acid (PGA biomaterial, which was lyophilized with hyaluronic acid (HA, for its utility to (a re-establish spinal stability and to (b seal annulus fibrosus defects. The biomechanical properties range of motion (ROM, neutral zone (NZ and a potential annulus sealing capacity were investigated. Methods Seven bovine, lumbar spinal units were tested in vitro for ROM and NZ in three consecutive stages: (a intact, (b following nucleotomy and (c after insertion of a PGA/HA nucleus-implant. For biomechanical testing, spinal units were mounted on a loading-simulator for spines. In three cycles, axial loading was applied in an excentric mode with 0.5 Nm steps until an applied moment of ± 7.5 Nm was achieved in flexion/extension. ROM and NZ were assessed. These tests were performed without and with annulus sealing by sewing a PGA/HA annulus-implant into the annulus defect. Results Spinal stability was significantly impaired after nucleotomy (p Conclusion PGA/HA biomaterial seems to be well suited for cell-free and cell-based regenerative treatment strategies in spinal surgery. Its abilities to restore spinal stability and potentially close annulus defects open up new vistas for regenerative approaches to treat intervertebral disc degeneration and for preventing implant herniation.

  5. Kinetic Modeling of Accelerated Stability Testing Enabled by Second Harmonic Generation Microscopy.

    Science.gov (United States)

    Song, Zhengtian; Sarkar, Sreya; Vogt, Andrew D; Danzer, Gerald D; Smith, Casey J; Gualtieri, Ellen J; Simpson, Garth J

    2018-04-03

    The low limits of detection afforded by second harmonic generation (SHG) microscopy coupled with image analysis algorithms enabled quantitative modeling of the temperature-dependent crystallization of active pharmaceutical ingredients (APIs) within amorphous solid dispersions (ASDs). ASDs, in which an API is maintained in an amorphous state within a polymer matrix, are finding increasing use to address solubility limitations of small-molecule APIs. Extensive stability testing is typically performed for ASD characterization, the time frame for which is often dictated by the earliest detectable onset of crystal formation. Here a study of accelerated stability testing on ritonavir, a human immunodeficiency virus (HIV) protease inhibitor, has been conducted. Under the condition for accelerated stability testing at 50 °C/75%RH and 40 °C/75%RH, ritonavir crystallization kinetics from amorphous solid dispersions were monitored by SHG microscopy. SHG microscopy coupled by image analysis yielded limits of detection for ritonavir crystals as low as 10 ppm, which is about 2 orders of magnitude lower than other methods currently available for crystallinity detection in ASDs. The four decade dynamic range of SHG microscopy enabled quantitative modeling with an established (JMAK) kinetic model. From the SHG images, nucleation and crystal growth rates were independently determined.

  6. Corrosion Control Test Method for Avionic Components

    Science.gov (United States)

    1981-09-25

    IFIED S• ’ECLASSIFICATION "’O14GRAOINU SC4 EMU LE 14 JJS’f’•UUr1N S AT& ME7N ’at .efil pot) Approved for public release; distribucion unlimited 17...Battery Output Increased Gradually as Compared to Normal Fog Effect S0 On 4,4 Took 25 min fur Battery Output to Stabilize S02 Off 2.2 1.8 ’Average...produced by carrier exposure except that there were localized areas where the normally white corrosion produces had a greenish tinge. Since these test

  7. Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning

    Directory of Open Access Journals (Sweden)

    Malou Hultcrantz

    2015-01-01

    Full Text Available Objective. To longitudinally follow the osseointegration using Resonance Frequency Analysis (RFA for different lengths of abutment on a new wide bone-anchored implant, introduced with the non-skin thinning surgical technique. Study Design. A single-center, prospective 1 year study following adults with bone-anchored hearing implants. Materials and Methods. Implantation was performed and followed for a minimum of 1 year. All patients were operated on according to the tissue preserving technique. A 4.5 mm wide fixture (Oticon Medical with varying abutments (9 to 12 mm was used and RFA was tested 1 week, 7 weeks, 6 months, and 12 months later. Implant Stability Quotient (ISQ, was measured from 1 to 100. Stability was compared to a group of patients (N=7 implanted with another brand (Cochlear BI400 of 4.5 mm fixtures. Results. All 10 adults concluded the study. None of the participants lost their implant during the test period indicating a good anchoring of abutments to the wide fixture tested. Stability testing was shown to vary depending on abutment length and time after surgery and with higher values for shorter abutments and increasing values over the first period of time. One patient changed the abutment from 12 to 9 mm and another from a 9 to a 12 during the year. No severe skin problems, numbness around the implant, or cosmetic problems arose. Conclusion. After 1 year of follow-up, combination of a wide fixture implant and the non-skin thinning surgical technique indicates a safe procedure with good stability and no abutment losses.

  8. Method and apparatus for testing microfilaments

    Science.gov (United States)

    Schleitweiler, Patrick M.; Merten, Jr., Charles W.

    1995-08-01

    A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament.

  9. Method and apparatus for testing microfilaments

    Energy Technology Data Exchange (ETDEWEB)

    Schleitweiler, P.M.; Merten, C.W. Jr.

    1995-08-01

    A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament. 2 figs.

  10. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  11. A new rapid high-throughput method for prediction of beer colloidal stability

    Czech Academy of Sciences Publication Activity Database

    Gabriel, P.; Sladký, P.; Sigler, Karel

    2016-01-01

    Roč. 122, č. 2 (2016), s. 304-309 ISSN 0046-9750 Institutional support: RVO:61388971 Keywords : colloidal stability * beer stabilization * forced aging test Subject RIV: GM - Food Processing Impact factor: 0.859, year: 2016

  12. Test Methods for Effects on Organisms

    DEFF Research Database (Denmark)

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology...

  13. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  14. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... TESTING A CONSENSUS CONFERENCE METHOD BY DISCUSSING THE MANAGEMENT OF TRAUMATIC DENTAL INJURIES IN TANZANIA ... treatment modalities of traumatic dental injuries recommended in western countries in the. Tanzanian situation. ..... fractured crown, leave alone a fractured.

  15. Stabilization of Joule Heating in the Electropyroelectric Method

    Science.gov (United States)

    Ivanov, R.; Hernández, M.; Marín, E.; Araujo, C.; Alaniz, D.; Araiza, M.; Martínez-Ordoñez, E. I.

    2012-11-01

    Recently the so-called electropyroelectric technique for thermal characterization of liquids has been proposed (Ivanov et al., J. Phys. D: Appl. Phys. 43, 225501 (2010)). In this method a pyroelectric sensor, in good thermal contact with the investigated sample, is heated by passing an amplitude-modulated electrical current through the electrical contacts. As a result of the heat dissipated to the sample, the pyroelectric signal measured as a voltage drop across the electrical contacts changes in a periodical way. The amplitude and phase of this signal can be measured by lock-in detection as a function of the electrical current modulation frequency. Because the signal amplitude and phase depend on the thermal properties of the sample, these can be determined straightforwardly by fitting the experimental data to a theoretical model based on the solution of the heat diffusion equation with proper boundary conditions. In general, the experimental conditions are selected so that the thermal effusivity becomes the measured magnitude. The technique has the following handicap. As the result of heating and wear of the metal coating layers (previously etched to achieve a serpentine form) with time, their electrical resistance changes with time, so that the heat power dissipated by the Joule effect can vary, and thermal effusivity measurement can become inaccurate. To avoid this problem in this study, a method is proposed that allows maintaining stable the Joule dissipated power. An electronic circuit is designed whose stability and characteristics are investigated and discussed.

  16. The Operational Testing Effectiveness Evaluation Method

    Science.gov (United States)

    1988-04-01

    objective evaluation method. 3 CHAPTER TWO HISTORICAL OT&E: A RESTLESS SEARCH We regard the creation of the testing and eva ]uation group as of the utmost...supervise it? Tracing the organiza- tional development of operational testing leads through a bewildering maze of command and staff structures. This chapter

  17. MODERN METHODS OF FOOD INTOLERANCE TESTING

    OpenAIRE

    M. Yu. Rosensteyn; A. Z. Rosensteyn; S. E. Kondakov; N. A. Cherevko

    2016-01-01

    Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  18. Modern methods for investigating the stability of a pitching floating platform wind turbine

    Directory of Open Access Journals (Sweden)

    M. Lennie

    2017-12-01

    Full Text Available The QBlade implementation of the lifting-line free vortex wake (LLFVW method was tested in conditions analogous to floating platform motion. Comparisons against two independent test cases using a variety of simulation methods show good agreement in thrust forces, rotor power, blade forces and rotor plane induction. Along with the many verifications already undertaken in the literature, it seems that the code performs solidly even in these challenging cases. Further to this, the key steps are presented from a new formulation of the instantaneous aerodynamic thrust damping of a wind turbine rotor. A test case with harmonic platform motion and collective blade pitch is used to demonstrate how combining such tools can lead to a better understanding of aeroelastic stability. A second case demonstrates a non-harmonic blade pitch manoeuvre showing the versatility of the instantaneous damping method.

  19. Best Practices in Stability Indicating Method Development and Validation for Non-clinical Dose Formulations.

    Science.gov (United States)

    Henry, Teresa R; Penn, Lara D; Conerty, Jason R; Wright, Francesca E; Gorman, Gregory; Pack, Brian W

    2016-11-01

    Non-clinical dose formulations (also known as pre-clinical or GLP formulations) play a key role in early drug development. These formulations are used to introduce active pharmaceutical ingredients (APIs) into test organisms for both pharmacokinetic and toxicological studies. Since these studies are ultimately used to support dose and safety ranges in human studies, it is important to understand not only the concentration and PK/PD of the active ingredient but also to generate safety data for likely process impurities and degradation products of the active ingredient. As such, many in the industry have chosen to develop and validate methods which can accurately detect and quantify the active ingredient along with impurities and degradation products. Such methods often provide trendable results which are predictive of stability, thus leading to the name; stability indicating methods. This document provides an overview of best practices for those choosing to include development and validation of such methods as part of their non-clinical drug development program. This document is intended to support teams who are either new to stability indicating method development and validation or who are less familiar with the requirements of validation due to their position within the product development life cycle.

  20. Powder Flow Testing: Judicious Choice of Test Methods.

    Science.gov (United States)

    Tay, Justin Yong Soon; Liew, Celine Valeria; Heng, Paul Wan Sia

    2017-07-01

    Flow property of pharmaceutical powders can be assessed by various flow testers and test methods. In this study, eight commercially available lactose grades were sourced and tested for angles of repose, tapping studies, shear cell measurements, stirred powder rheometry, and avalanching powder measurements. The relationships between various flow parameters and particle size were analyzed. Deviations from the general trend could be attributed to either the insensitivity of the test or differences in particle shape. The basic flowability energy of the powder rheometer was unable to reconcile the effects of shape and particle size on powder flowability. Avalanche time of the revolving drum powder analyzer and angle of repose exhibited good correlation with each other (r = 0.92) but experienced poor resolution for samples of smaller particle sizes due to powder cohesiveness and the propensity for agglomerative flow. Flow test parameters could be categorized into three broad types, based on their relationship with particle size: (i) linear relationship, (ii) test parameter more sensitive to smaller sized particles, and (iii) test parameter more sensitive to larger sized particles. Choice of test parameters used to represent powder flow should be dependent on the sensitivity of the selected flow test methods to the sample types.

  1. Stability of Quadratic Functional Equations via the Fixed Point and Direct Method

    Directory of Open Access Journals (Sweden)

    Son Eunyoung

    2010-01-01

    Full Text Available Cădariu and Radu applied the fixed point theorem to prove the stability theorem of Cauchy and Jensen functional equations. In this paper, we prove the generalized Hyers-Ulam stability via the fixed point method and investigate new theorems via direct method concerning the stability of a general quadratic functional equation.

  2. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard test method for instrumented impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard establishes the requirements for performing instrumented Charpy V-Notch (CVN) and instrumented Miniaturized Charpy V-Notch (MCVN) impact tests on metallic materials. This method, which is based on experience developed testing steels, provides further information (in addition to the total absorbed energy) on the fracture behavior of the tested materials. Minimum requirements are given for measurement and recording equipment such that similar sensitivity and comparable total absorbed energy measurements to those obtained in Test Methods E 23 and E 2248 are achieved. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Aircraft directional stability and vertical tail design: A review of semi-empirical methods

    Science.gov (United States)

    Ciliberti, Danilo; Della Vecchia, Pierluigi; Nicolosi, Fabrizio; De Marco, Agostino

    2017-11-01

    Aircraft directional stability and control are related to vertical tail design. The safety, performance, and flight qualities of an aircraft also depend on a correct empennage sizing. Specifically, the vertical tail is responsible for the aircraft yaw stability and control. If these characteristics are not well balanced, the entire aircraft design may fail. Stability and control are often evaluated, especially in the preliminary design phase, with semi-empirical methods, which are based on the results of experimental investigations performed in the past decades, and occasionally are merged with data provided by theoretical assumptions. This paper reviews the standard semi-empirical methods usually applied in the estimation of airplane directional stability derivatives in preliminary design, highlighting the advantages and drawbacks of these approaches that were developed from wind tunnel tests performed mainly on fighter airplane configurations of the first decades of the past century, and discussing their applicability on current transport aircraft configurations. Recent investigations made by the authors have shown the limit of these methods, proving the existence of aerodynamic interference effects in sideslip conditions which are not adequately considered in classical formulations. The article continues with a concise review of the numerical methods for aerodynamics and their applicability in aircraft design, highlighting how Reynolds-Averaged Navier-Stokes (RANS) solvers are well-suited to attain reliable results in attached flow conditions, with reasonable computational times. From the results of RANS simulations on a modular model of a representative regional turboprop airplane layout, the authors have developed a modern method to evaluate the vertical tail and fuselage contributions to aircraft directional stability. The investigation on the modular model has permitted an effective analysis of the aerodynamic interference effects by moving, changing, and

  5. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  6. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Development and validation of a stability indicating HPTLC-densitometric method for lafutidine

    Directory of Open Access Journals (Sweden)

    Dinesh Dhamecha

    2013-01-01

    Full Text Available Background: A simple, selective, precise, and stability indicating high-performance thin layer chromatographic method has been established and validated for analysis of lafutidine in bulk drug and formulations. Materials and Methods: The compounds were analyzed on aluminum backed silica gel 60 F 254 plates with chloroform:ethanol:acetic Acid (8:1:1 as mobile phase. Densitometric analysis of lafutidine was performed at 230 nm. Result : Regression analysis data for the calibration plots were indicative of good linear relationship between response and concentration over the range 100-500 ng per spot. The correlation coefficient (r 2 was 0.998±0.002. Conclusion: Lafutidine was subjected to acid, base, peroxide, and sunlight degradation. In stability tests, the drug was susceptible to acid and basic hydrolysis, oxidation, and photodegradation.

  8. Evaluation of enhancements to Thevenin equivalent based methods for real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2014-01-01

    The possibilities offered by the use of Phasor Measurement Units (PMU) in real - time monitoring provide interesting ways to ensure secure operation of power systems. This paper studies the specific case of voltage stability and the possible improvements to the Thevenin equivalent methods, which...... is applied generally with local measurements. This paper uses the PMU measurements to calculate the grid transformation coefficients to obtain wide - area information. This is achieved by studying the generator's electromo tive force estimated using values in the coefficient transformation matrix....... The improvements are tested in a small system and a through comparison with traditional Thevenin equivalent methods is carried out....

  9. DC-10 composite vertical stabilizer ground test program

    Science.gov (United States)

    Palmer, J. M., Jr.; Stephens, C. O.; Sutton, J. O.

    1983-01-01

    A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

  10. A Stabilized Finite Element Method for Compressible Phase Change Problems

    Science.gov (United States)

    Zhang, Yu; Yang, Fan; Chandra, Anirban; Shams, Ehsan; Shephard, Mark; Sahni, Onkar; Oberai, Assad

    2017-11-01

    The numerical modeling of multi-phase interfacial phase change phenomena, such as evaporation of a liquid or combustion of a solid, is essential for several important applications. A mathematically consistent and robust computational approach to address challenges such as large density ratio across phases, discontinuous fields at the interface, rapidly evolving geometries, and compressible phases, is presented in this work. We use the stabilized finite element methods on unstructured grids for solving the compressible Navier-Stokes equations. The rate of phase change rate is predicted from thermodynamic variables on both sides of the interface. We enforce the continuity of temperature and velocity in the tangential direction by using a penalty approach, while appropriate jump conditions derived from conservation laws across the interface are handled by using discontinuous interpolations. The interface is explicitly tracked using the arbitrary Lagrangian-Eulerian (ALE) technique, wherein the grid at the interface is constrained to move with the interface. This work is supported by the U.S. Army Grants W911NF1410301 and W911NF16C0117.

  11. Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation

    NARCIS (Netherlands)

    van Heugten, A J P; Boer, W.; de Vries, W S; Markesteijn, C M A; Vromans, H

    2018-01-01

    A stability indicating high performance liquid chromatography method has been developed for the determination of triamcinolone acetonide (TCA) and its main degradation products in ointment formulations. The method, based on extensive stress testing using metal salts, azobisisobutyronitrile, acid,

  12. apllication of lyapunov's second method in the stability analysis of oil ...

    African Journals Online (AJOL)

    NIJOTECH

    linear) is to evaluate its dynamic stability. For non-linear systems, several methods have already been developed for this purpose. They are Nyquist's, Popov's and Lyapunov's methods. [1]. Among those methods, Lyapunov's method (second.

  13. Design, ancillary testing, analysis and fabrication data for the advanced composite stabilizer for Boeing 737 aircraft. Volume 1: Technical summary

    Science.gov (United States)

    Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parsons, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.

    1983-01-01

    The horizontal stabilizer of the 737 transport was redesigned. Five shipsets were fabricated using composite materials. Weight reduction greater than the 20% goal was achieved. Parts and assemblies were readily produced on production-type tooling. Quality assurance methods were demonstrated. Repair methods were developed and demonstrated. Strength and stiffness analytical methods were substantiated by comparison with test results. Cost data was accumulated in a semiproduction environment. FAA certification was obtained.

  14. Revisiting test stability: further evidence relating to the measurement ...

    African Journals Online (AJOL)

    In several earlier analyses of two tests of academic literacy – the Test of Academic Literacy Levels (TALL) and its Afrikaans counterpart, the Toets vir Akademiese Geletterdheidsvlakke (TAG) – we have adopted an approach to the problem that tests may be abused (and therefore used to harm people) by discussing various ...

  15. A hybrid method for optimal load shedding and improving voltage stability

    Directory of Open Access Journals (Sweden)

    V. Tamilselvan

    2016-03-01

    Full Text Available In this paper, a hybrid method is proposed for reducing the amount of load shedding and voltage collapse. The hybrid method is the combination of Genetic Algorithm (GA and Neural Network (NN. The GA is used by two stages, one is to frame the optimization model and other stage is to generate data set for developing the NN based intelligent load shedding model. The appropriate buses for load shedding are selected based on the sensitivity of minimum eigenvalue of load flow Jacobian with respect to the load shed. The proposed method is implemented in MATLAB working platform and the performance is tested with 6 bus and IEEE 14 bus bench mark system. The result of the proposed hybrid method is compared with the GA based optimization algorithm. The comparison shows that, the proposed method ensures voltage stability with minimum loading shedding.

  16. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  17. Improving the Stability and Accuracy of Power Hardware-in-the-Loop Simulation Using Virtual Impedance Method

    Directory of Open Access Journals (Sweden)

    Xiaoming Zha

    2016-11-01

    Full Text Available Power hardware-in-the-loop (PHIL systems are advanced, real-time platforms for combined software and hardware testing. Two paramount issues in PHIL simulations are the closed-loop stability and simulation accuracy. This paper presents a virtual impedance (VI method for PHIL simulations that improves the simulation’s stability and accuracy. Through the establishment of an impedance model for a PHIL simulation circuit, which is composed of a voltage-source converter and a simple network, the stability and accuracy of the PHIL system are analyzed. Then, the proposed VI method is implemented in a digital real-time simulator and used to correct the combined impedance in the impedance model, achieving higher stability and accuracy of the results. The validity of the VI method is verified through the PHIL simulation of two typical PHIL examples.

  18. Review of test methods for coating adhesion

    International Nuclear Information System (INIS)

    Maxwell, A.S.

    2001-01-01

    The following report summarises the results of a literature search and a series of industrial surveys that have been conducted to determine the current status of test methods for the measurement of coating adhesion. The review consists of: a list of test methods that have been identified from current scientific literature; a short description of the methodologies used in industry; a review of applicable standards; a summary of recent scientific reviews; and the results from two recent industrial surveys conducted by the National Physical Laboratory (NPL) and the National Institute of Standards and Technology (NIST) into current industrial practice. (author)

  19. Surface stability and small-scale testing of zirconia

    OpenAIRE

    Camposilvan, Erik

    2015-01-01

    Tesi per compendi de publicacions. La consulta íntegra de la tesi, inclosos els articles no comunicats públicament per drets d'autor, es pot realitzar prèvia petició a l'Arxiu UPC Tetragonal polycrystalline zirconia stabilized with 3 mol% of yttria (3Y-TZP) is a biocompatible ceramic showing superior mechanical properties, which are partly the consequence of phase transformation: the tetragonal metastable phase can transform, with a net volume increase, to the stable monoclinic phase by a ...

  20. Alternative Test Methods for Developmental Neurotoxicity: A ...

    Science.gov (United States)

    Exposure to environmental contaminants is well documented to adversely impact the development of the nervous system. However, the time, animal and resource intensive EPA and OECD testing guideline methods for developmental neurotoxicity (DNT) are not a viable solution to characterizing potential chemical hazards for the thousands of untested chemicals currently in commerce. Thus, research efforts over the past decade have endeavored to develop cost-effective alternative DNT testing methods. These efforts have begun to generate data that can inform regulatory decisions. Yet there are major challenges to both the acceptance and use of this data. Major scientific challenges for DNT include development of new methods and models that are “fit for purpose”, development of a decision-use framework, and regulatory acceptance of the methods. It is critical to understand that use of data from these methods will be driven mainly by the regulatory problems being addressed. Some problems may be addressed with limited datasets, while others may require data for large numbers of chemicals, or require the development and use of new biological and computational models. For example mechanistic information derived from in vitro DNT assays can be used to inform weight of evidence (WoE) or integrated approaches to testing and assessment (IATA) approaches for chemical-specific assessments. Alternatively, in vitro data can be used to prioritize (for further testing) the thousands

  1. Combined nondestructive testing method for ceramic products

    International Nuclear Information System (INIS)

    Baranov, V.M.; Ermolaev, S.M.; Zhukova, L.M.; Kudryavtsev, E.M.; Kozlov, V.V.; Samokhvalov, A.N.

    1990-01-01

    Methods of defectoscopy of ceramic products based on joint application of ultrasonic resonance spectroscopy and gamma-absorption radiometry are suggested. Due to joint process of data it is possible to establish both the presence and the type of available defects. The conclusion about the character of defects is made on the basis of getting into one or another region of change in complex testing parameters of informative feature impact recorded in tests. The results of ceramography confirming data on nondestructive testing are presented

  2. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  3. Results of Long-Term Stability Tests Performed for the Eutectics Co-C and Pt-C

    Science.gov (United States)

    Wang, T.; Bai, C.; Dong, W.; Yuan, Z.; Bloembergen, P.; Liu, F.

    2011-08-01

    The stability of the Co-C and Pt-C eutectic fixed points is investigated in this article. Six cells were employed for the testing. Two existing cells, a Co-C cell with a C/C sheet incorporated and a Pt-C cell equipped with a graphite sleeve that had been previously aged, were studied to determine the presence of anomalous drifts or degrading robustness that may possibly appear when the testing period is extended. The stability of four cells of a new design, a Co-C cell and three Pt-C cells, which were constructed in a hybrid manner, to include a sleeve, foil lining, and two of them with a cavity support, were likewise tested. Results show that different designs of Pt-C cells can exhibit good stability. However, for Co-C cells, the cavity rift remains a problem. The possible reasons for this rift and methods for increasing cell life are discussed.

  4. In Vitro Evaluation of Dimensional Stability of Alginate Impressions after Disinfection by Spray and Immersion Methods

    Directory of Open Access Journals (Sweden)

    Fahimeh Hamedi Rad

    2010-12-01

    Full Text Available Background and aims. The most common method for alginate impression disinfection is spraying it with disinfecting agents, but some studies have shown that these impressions can be immersed, too. The aim of this study was to evaluate the dimensional stability of alginate impressions following disinfecting by spray and immersion methods. Materials and methods. Four common disinfecting agents (Sodium Hypochlorite, Micro 10, Glutaraldehyde and Deconex were selected and the impressions (n=108 were divided into four groups (n=24 and eight subgroups (n=12 for disinfecting by any of the four above-mentioned agents by spray or immersion methods. The control group (n=12 was not disinfected. Then the impressions were poured by type III Dental Stone Plaster in a standard method. The results were analyzed by descriptive methods (mean and standard deviation, t-test, two-way analysis of variance (ANOVA and Duncan test, using SPSS 14.0 software for windows. Results. The mean changes of length and height were significant between the various groups and disinfecting methods. Regarding the length, the greatest and the least amounts were related to Deconex and Micro 10 in the immersion method, respectively. Regarding height, the greatest and the least amounts were related to Glutaraldehyde and Deconex in the immersion method, respectively. Conclusion. Disinfecting alginate impressions by Sodium Hypochlorite, Deconex and Glutaraldehyde by immersion method is not recommended and it is better to disinfect alginate impressions by spraying of Micro 10, Sodium Hypochlorite, Glutaraldehyde and immersion in Micro 10.

  5. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  6. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  7. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  8. Methods for prostate stabilization during transperineal LDR brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Yu Yan; Sherman, Jason; Rubens, Deborah; Strang, John; Messing, Edward; Ng, Wan-Sing

    2008-01-01

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  9. 46 CFR 170.185 - Stability test preparations.

    Science.gov (United States)

    2010-10-01

    ... test: (a) The vessel must be as complete as practicable at the time of the test. (b) Each tank vessel...) The water depth at the mooring site must provide ample clearance against grounding. (e) Each mooring... that result in acceptable accuracy in calculating the center of gravity and displacement of the unit...

  10. Simple test for physical stability of cryogenic tank insulation

    Science.gov (United States)

    Rossello, D.

    1968-01-01

    Qualitative test determines the ability of insulation liners used on liquid hydrogen tanks to withstand stresses produced by the thermal shocks imparted to the insulation during tank filling and drainage. Test specimens are bonded to metal plates with a low thermal expansion coefficient and are immersed in liquid hydrogen.

  11. PEP Support: Laboratory Scale Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2010-05-21

    This report documents results from a variety of activities requested by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The activities related to caustic leaching, oxidative leaching, permeate precipitation behavior of waste as well as chromium (Cr) leaching are: • Model Input Boehmite Leaching Tests • Pretreatment Engineering Platform (PEP) Support Leaching Tests • PEP Parallel Leaching Tests • Precipitation Study Results • Cr Caustic and Oxidative Leaching Tests. Leaching test activities using the PEP simulant provided input to a boehmite dissolution model and determined the effect of temperature on mass loss during caustic leaching, the reaction rate constant for the boehmite dissolution, and the effect of aeration in enhancing the chromium dissolution during caustic leaching. Other tests were performed in parallel with the PEP tests to support the development of scaling factors for caustic and oxidative leaching. Another study determined if precipitate formed in the wash solution after the caustic leach in the PEP. Finally, the leaching characteristics of different chromium compounds under different conditions were examined to determine the best one to use in further testing.

  12. Verifiable Measurement-Only Blind Quantum Computing with Stabilizer Testing.

    Science.gov (United States)

    Hayashi, Masahito; Morimae, Tomoyuki

    2015-11-27

    We introduce a simple protocol for verifiable measurement-only blind quantum computing. Alice, a client, can perform only single-qubit measurements, whereas Bob, a server, can generate and store entangled many-qubit states. Bob generates copies of a graph state, which is a universal resource state for measurement-based quantum computing, and sends Alice each qubit of them one by one. Alice adaptively measures each qubit according to her program. If Bob is honest, he generates the correct graph state, and, therefore, Alice can obtain the correct computation result. Regarding the security, whatever Bob does, Bob cannot get any information about Alice's computation because of the no-signaling principle. Furthermore, malicious Bob does not necessarily send the copies of the correct graph state, but Alice can check the correctness of Bob's state by directly verifying the stabilizers of some copies.

  13. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  14. ``Retests'': A better method of test corrections

    Science.gov (United States)

    McManus, Jeff

    2011-02-01

    Physics instructors at all levels employ a variety of techniques to encourage students to reflect on and correct mistakes made on quizzes, unit tests, or exams. A thorough analysis of several methods was recently published in these pages that compared several variations of quiz corrections in college courses. One common method is to have students rewrite the solutions to the questions or problems that they missed, with the goal of earning some part of the missed points. While this method is helpful for some students, it often discourages students with already decent grades to reflect on their work. I use a method called "retesting" with my AP® Physics C students that I learned from my high school geometry teacher, Bill Kramer. I feel his clever method offers significant advantages over more traditional approaches.

  15. Immunochemical faecal occult blood tests have superior stability and analytical performance characteristics over guaiac-based tests in a controlled in vitro study.

    LENUS (Irish Health Repository)

    Lee, Chun Seng

    2011-06-01

    The aims of this study were (1) to determine the measurement accuracy of a widely used guaiac faecal occult blood test (gFOBT) compared with an immunochemical faecal occult blood test (iFOBT) during in vitro studies, including their analytical stability over time at ambient temperature and at 4°C; and (2) to compare analytical imprecision and other characteristics between two commercially available iFOBT methods.

  16. Thermal stability of Al-Cu-Fe quasicrystals prepared by SHS method

    Directory of Open Access Journals (Sweden)

    Pavel Novak

    2013-02-01

    Full Text Available Quasicrystal-containing materials are usually prepared by rapid solidification of the melt (e.g. by melt spinning or mechanical alloying. In this work, the method using exothermic reactions between compressed metallic powders called SHS (Self-propagating High-temperature Synthesis was tested. The microstructure and phase composition of the product was described in dependence on cooling regime from the reaction temperature. Thermal stability of prepared Al-Cu-Fe quasicrystals was studied by annealing at the temperatures of 300 and 500 °C.

  17. THERMAL STABILITY OF Al-Cu-Fe QUASICRYSTALS PREPARED BY SHS METHOD

    Directory of Open Access Journals (Sweden)

    Pavel Novák

    2013-04-01

    Full Text Available Quasicrystal-containing materials are usually prepared by rapid solidification of the melt (e.g. by melt spinning or mechanical alloying. In this work, the method using exothermic reactions between compressed metallic powders called SHS (Self-propagating High-temperature Synthesis was tested. The microstructure and phase composition of the product was described in dependence on cooling regime from the reaction temperature. Thermal stability of prepared Al-Cu-Fe quasicrystals was studied by annealing at the temperatures of 300 and 500 °C.

  18. Stability-indicating RP-HPLC method for the simultaneous determination of escitalopram oxalate and clonazepam.

    Science.gov (United States)

    Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G

    2013-07-01

    The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.

  19. An ultrasonic-accelerated oxidation method for determining the oxidative stability of biodiesel.

    Science.gov (United States)

    Avila Orozco, Francisco D; Sousa, Antonio C; Domini, Claudia E; Ugulino Araujo, Mario Cesar; Fernández Band, Beatriz S

    2013-05-01

    Biodiesel is considered an alternative energy because it is produced from fats and vegetable oils by means of transesterification. Furthermore, it consists of fatty acid alkyl esters (FAAS) which have a great influence on biodiesel fuel properties and in the storage lifetime of biodiesel itself. The biodiesel storage stability is directly related to the oxidative stability parameter (Induction Time - IT) which is determined by means of the Rancimat® method. This method uses condutimetric monitoring and induces the degradation of FAAS by heating the sample at a constant temperature. The European Committee for Standardization established a standard (EN 14214) to determine the oxidative stability of biodiesel, which requires it to reach a minimum induction period of 6h as tested by Rancimat® method at 110°C. In this research, we aimed at developing a fast and simple alternative method to determine the induction time (IT) based on the FAAS ultrasonic-accelerated oxidation. The sonodegradation of biodiesel samples was induced by means of an ultrasonic homogenizer fitted with an immersible horn at 480Watts of power and 20 duty cycles. The UV-Vis spectrometry was used to monitor the FAAS sonodegradation by measuring the absorbance at 270nm every 2. Biodiesel samples from different feedstock were studied in this work. In all cases, IT was established as the inflection point of the absorbance versus time curve. The induction time values of all biodiesel samples determined using the proposed method was in accordance with those measured through the Rancimat® reference method by showing a R(2)=0.998. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Space shuttle maneuvering engine reusable thrust chamber program. Task 11: Low Epsilon stability test plan

    Science.gov (United States)

    Pauckert, R. P.

    1974-01-01

    The performance and heat transfer characteristics of a doublet element type injector for the space shuttle orbiter maneuvering engine thrust chamber were investigated. Ths stability characteristics were evaluated over a range of chamber pressures and mixture ratios. The specific objectives of the test were: (1) to determine whether stability has been influenced by injection of boundary layer coolant across the cavity entrance, (2) if the injector is stable, to determine the minimum cavity area required to maintain stability, and (3) if the injector is unstable, to determine the effects of entrance geometry and increased area on stability.

  1. Aggregate stability by the "high energy moisture characteristic" method in an oxisol under differentiated management

    Directory of Open Access Journals (Sweden)

    Érika Andressa da Silva

    2014-10-01

    Full Text Available Studies testing the High Energy Moisture Characteristic (HEMC technique in tropical soils are still incipient. By this method, the effects of different management systems can be evaluated. This study investigated the aggregation state of an Oxisol under coffee with Brachiaria between crop rows and surface-applied gypsum rates using HEMC. Soil in an experimental area in the Upper São Francisco region, Minas Gerais, was studied at depths of 0.05 and 0.20 m in coffee rows. The treatments consisted of 0, 7, and 28 Mg ha-1 of agricultural gypsum rates distributed on the soil surface of the coffee rows, between which Brachiaria was grown and periodically cut, and compared with a treatment without Brachiaria between coffee rows and no gypsum application. To determine the aggregation state using the HEMC method, soil aggregates were placed in a Büchner funnel (500 mL and wetted using a peristaltic pump with a volumetric syringe. The wetting was applied increasingly at two pre-set speeds: slow (2 mm h-1 and fast (100 mm h-1. Once saturated, the aggregates were exposed to a gradually increasing tension by the displacement of a water column (varying from 0 to 30 cm to obtain the moisture retention curve [M = f (Ψ ], underlying the calculation of the stability parameters: modal suction, volume of drainable pores (VDP, stability index (slow and fast, VDP ratio, and stability ratio. The HEMC method conferred sensitivity in quantifying the aggregate stability parameters, and independent of whether gypsum was used, the soil managed with Brachiaria between the coffee rows, with regular cuts discharged in the crop row direction, exhibited a decreased susceptibility to disaggregation.

  2. A stabilized cut finite element method for the Darcy problem on surfaces

    Science.gov (United States)

    Hansbo, Peter; G. Larson, Mats; Massing, André

    2017-11-01

    We develop a cut finite element method for the Darcy problem on surfaces. The cut finite element method is based on embedding the surface in a three dimensional finite element mesh and using finite element spaces defined on the three dimensional mesh as trial and test functions. Since we consider a partial differential equation on a surface, the resulting discrete weak problem might be severely ill conditioned. We propose a full gradient and a normal gradient based stabilization computed on the background mesh to render the proposed formulation stable and well conditioned irrespective of the surface positioning within the mesh. Our formulation extends and simplifies the Masud-Hughes stabilized primal mixed formulation of the Darcy surface problem proposed in [28] on fitted triangulated surfaces. The tangential condition on the velocity and the pressure gradient is enforced only weakly, avoiding the need for any tangential projection. The presented numerical analysis accounts for different polynomial orders for the velocity, pressure, and geometry approximation which are corroborated by numerical experiments. In particular, we demonstrate both theoretically and through numerical results that the normal gradient stabilized variant results in a high order scheme.

  3. Investigations of blood ammonia analysis: Test matrices, storage, and stability.

    Science.gov (United States)

    Goldstein, Brittany N; Wesler, Jordan; Nowacki, Amy S; Reineks, Edmunds; Natowicz, Marvin R

    2017-06-01

    An assessment of blood ammonia concentration is common medical practice in the evaluation of an individual with an unexplained mental status change or coma. The determination of a blood ammonia level is most commonly done using a glutamate dehydrogenase (GLDH)-based assay, although there are many potential sources of artifact and the literature is inconsistent regarding key preanalytic issues. Using a GLDH-based assay, we first investigated matrix effects using three anticoagulants: heparin, EDTA and oxalate. Heparin-anticoagulated plasma was substantially less precise than EDTA- and oxalate-anticoagulated plasma. Oxalate-anticoagulated plasma showed a greater baseline of apparent ammonia than either heparin- or EDTA-derived plasma, presumably due to interferants. We then evaluated the stability of EDTA-anticoagulated plasma for assessment of ammonia when stored at 4°C,-14°C or -70°C. There was a linear increase of ammonia with storage at both 4°C and -14°C. Plasma kept at -70°C for up to three weeks showed no change in measured ammonia relative to the baseline determination. This work clarifies preanalytic conditions for which a precise determination of ammonia can be accomplished using a GLDH-based assay. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Stability estimates for hp spectral element methods for elliptic ...

    Indian Academy of Sciences (India)

    In each of these sectoral neighborhoods we use a local coordinate system ( k , k ) where k = l n r k and ( r k , k ) are polar coordinates with origin at A k , as first proposed by Kondratiev. We then derive differentiability estimates with respect to these new variables and a stability estimate for the functional we minimize.

  5. An alternative method to specify the degree of resonator stability

    Indian Academy of Sciences (India)

    maximum value of the degree of stability corresponding to S = 100%, automatically corresponds to g1g2 = 1/2. We also describe an experimental technique to measure the S parameter from the laser output beam characteristics and B parameter. The measured value of S parameter is in close agreement with the predicted ...

  6. Biological stability of drinking water : Controlling factors, methods, and challenges

    NARCIS (Netherlands)

    Prest, E.I.E.D.; Hammes, F.; Van Loosdrecht, M.C.M.; Vrouwenvelder, J.S.

    2016-01-01

    Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and

  7. Stability over Time of Different Methods of Estimating School Performance

    Science.gov (United States)

    Dumay, Xavier; Coe, Rob; Anumendem, Dickson Nkafu

    2014-01-01

    This paper aims to investigate how stability varies with the approach used in estimating school performance in a large sample of English primary schools. The results show that (a) raw performance is considerably more stable than adjusted performance, which in turn is slightly more stable than growth model estimates; (b) schools' performance…

  8. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  9. Methods and instruments for materials testing

    Science.gov (United States)

    Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)

    2011-01-01

    Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.

  10. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  11. Environmental Stability Testing of a Coated, Elastomeric Dental Ribbon.

    Science.gov (United States)

    1979-09-01

    soe or " esa PWXZ S 16CURITV CLASIFICATION OF THIS PAGR(Ihusa t Eftmem percent) respectively.) Modulus were 5.0,0.18, 0.14 and 0.08 (xl05 p.s.i...lengths were measured with a steel ruler (to 0.01 inch). **Conditioning Specimens tested at temperatures above and below roo. temperature were conditioned

  12. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    definition (XSD) format and other standards and conventions. This method should be of interest primarily to parties having tools or applications that...consume RCC metadata standard documents, and may be of interest to developers of tools or applications that produce RCC metadata standard documents...instance document and encodings to verify that the rules engines and other tools work together. 1. Initialize the programming environment. 2. Write test

  13. Test of Cable Products in Respect of Thermal and Dynamic Stability

    Directory of Open Access Journals (Sweden)

    M. A. Коrotkevich

    2010-01-01

    Full Text Available The paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.

  14. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management......Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  15. Improved method for fluorescence cytometric immunohematology testing.

    Science.gov (United States)

    Roback, John D; Barclay, Sheilagh; Hillyer, Christopher D

    2004-02-01

    A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. A modified procedure was developed that used low-speed centrifugation of 96-well filter plates for RBC staining. Small-footprint benchtop capillary cytometers (PCA and PCA-96, Guava Technologies, Inc.) were used for data acquisition. Authentic clinical samples from hospitalized patients were tested for ABO group and the presence of D antigen (n = 749) as well as for the presence of RBC alloantibodies (n = 428). Challenging samples with mixed-field reactions and weak antibodies were included. Results were compared to those obtained by column agglutination technology (CAT), and discrepancies were resolved by standard tube methods. Detailed investigations of FC sensitivity and reproducibility were also performed. The modified FC method with the PCA determined the correct ABO group and D type for 98.7 percent of 520 samples, compared to 98.8 percent for CAT (p > 0.05). No-type-determined (NTD) rates were 1.2 percent for both methods. In testing for unexpected alloantibodies, FC determined the correct result for 98.6 percent of 215 samples, compared to 96.3 percent for CAT (p > 0.05). When samples were automatically acquired in the 96-well plate format with the PCA-96, 98.7 percent of 229 samples had correct ABO group and D type determined by FC, compared to 97.4 percent for CAT (p > 0.05). NTD rates were 0.9 and 2.6 percent, respectively. Antibody screens were accurate for 99.1 percent of 213 samples with the PCA-96, compared to 99.5 percent for CAT (p > 0.05). Further investigations demonstrated that FC with the PCA-96 was better than CAT at detecting weak anti-A (p < 0.0001) and alloantibodies. An improved method for FC immunohematology testing has been described. This assay was comparable

  16. Numerical Investigations on Several Stabilized Finite Element Methods for the Stokes Eigenvalue Problem

    Directory of Open Access Journals (Sweden)

    Pengzhan Huang

    2011-01-01

    Full Text Available Several stabilized finite element methods for the Stokes eigenvalue problem based on the lowest equal-order finite element pair are numerically investigated. They are penalty, regular, multiscale enrichment, and local Gauss integration method. Comparisons between them are carried out, which show that the local Gauss integration method has good stability, efficiency, and accuracy properties, and it is a favorite method among these methods for the Stokes eigenvalue problem.

  17. Development and validation of a thin-layer chromatography method for stability studies of naproxen

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Rodriguez Borges, Tania

    2011-01-01

    The validation of an analytical method was carried out to be applied to the stability studies of the future formulations of naproxen suppositories for infant and adult use. The factors which mostly influenced in the naproxen stability were determined, the major degradation occurred in oxidizing acid medium and by action of light. The possible formation of esters between the free carboxyl group present in naproxen and the glyceryl monoestereate present in the base was identified as one of the degradation paths in the new formulation. The results were satisfactory. A thin-layer chromatography-based method was developed as well as the best chromatographic conditions were selected. GF 254 silica gel plates and ultraviolet developer at 254 nm were employed. Three solvent systems were evaluated of which A made up of glacial acetic: tetrahydrofurane:toluene (3:9:90 v/v/v)allowed adequate resolution between the analyte and the possible degradation products, with detection limit of 1 μg. The use of the suggested method was restricted to the identification of possible degradation products just for qualitative purposes and not as final test. The method proved to be sensitive and selective enough to be applied for the stated objective, according to the validation results

  18. Improved grindability test: essential refinements to method

    Energy Technology Data Exchange (ETDEWEB)

    Dick Sanders [QCC Resources (Australia)

    2007-01-15

    Under Project C12063 a test was developed and demonstrated which overcame all of the deficiencies of the Standard Hardgrove Grindability Index (HGI) Test. It used a standard volume of a representative 'by zero' sample, and expressed the results of the standard grind in terms of the Sauter mean diameter, SMD (in {mu}m). The test was named the Improved Grindability Test (IGT). In Project C13065 a steady state IGT was developed. A modification to the method was needed to overcome the effect of prior breakage and this was the basis for this project. Six coals of widely varying type were sampled at exposed coal faces i.e. with no prior breakage history. These were dropped repeatedly, crushed to pass 50 mm, and divided into A and B streams. A was 'gently' crushed to pass 8 mm (jaw crusher), while B was 'vigorously' crushed to pass 8 mm. Each -8 mm sample was then crushed to pass 2 mm by passing about ten times through a plate mill with progressively closer settings. The results have shown that the effects of prior breakage history can be substantially minimised, although not completely eliminated (especially for the softest coals), by increasing the starting sample top size from 4.75 to 8 mm and crushing all of the sample each time, for a large number of passes, to the 2 mm top size for the IGT test. Testing outcomes, and the interpretation of results, have been significantly compromised by sample losses during preparation and testing. Precision at a given laboratory seems acceptable, although agreement between laboratories is disappointing. The Steady State version of the IGT shows great promise, with the mass% of -75 {mu}m produced by grinding, under 'steady state' conditions (5 minutes) being a useful indicator of a coal's grindability.

  19. Alternative Methods of Frying and Antioxidant Stability in Soybean Oil

    OpenAIRE

    Probir Kumar Ghosh; Dipan Chatterjee; Paramita Bhattacharjee

    2012-01-01

    A study on shallow and parfrying in soybean oil as alternatives to deep frying and evaluation of stability of a formulated antioxidant administered to the oil was conducted. Potato wedges were deep, shallow and parfried in soybean oil for optimized time and temperature. A citric acid based antioxidant using BHT was formulated and administered to the oils before frying. The performance of antioxidant was assessed by studying its physicochemical properties and DPPH radical scavenging activity w...

  20. A simple method for estimating the superaromatic stabilization energy of a super-ring molecule.

    Science.gov (United States)

    Aihara, Jun-Ichi

    2008-05-08

    A simple graph-theoretical method is proposed for readily estimating the degree of extra stabilization due to macrocyclic conjugation (superaromaticity). This method is based theoretically on the concept of circuit resonance energy previously defined for cyclic pi systems. We confirmed that kekulene and related super-ring molecules are essentially nonsuperaromatic, with very small superaromatic stabilization energies.

  1. Unique continuation for the Helmholtz equation using stabilized finite element methods

    OpenAIRE

    Burman, Erik; Nechita, Mihai; Oksanen, Lauri

    2017-01-01

    We solve a unique continuation problem for the Helmholtz equation using a stabilized finite element method. We first derive conditional stability estimates with constants independent of the wave number $k$, which we then use to obtain error estimates for the finite element method that are robust and explicit with respect to $k$. Some numerical illustrations are given.

  2. Improved Thévenin equivalent methods for real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2016-01-01

    An improved Thévenin equivalent method for real-time voltage stability assessment that uses wide-area information from synchrophasors is proposed. The improvements are a better modeling of the limited synchronous generators, and a processing that anticipates the effect of field current limiters...... with the sensitivity-based voltage stability assessment method is explored....

  3. Testing the effect of a microbial-based soil amendment on aggregate stability and erodibility

    DEFF Research Database (Denmark)

    Malozo, Mponda; Iversen, Bo Vangsø; Heckrath, Goswin Johann

    Minimizing soil erosion is essential for maintaining proper soil quality and thus preserving soil productivity. The erodibility of a soil is closely linked to its structural stability as well as its infiltrability. This study focuses on testing the effect of two different soil amendments on soil...... aggregate stability and erodibility. Two commercial products, gypsum and a microbial-based solution were used for the experiment and were tested on two Danish sandy loamy soils as well on a sandy soil from Tanzania. The carrier of the microbial-based product, a glycerol solution, was tested as well....... In the laboratory, soils were treated with the soil amendments in a two-step procedure at controlled water contents following aerobic incubation in closed containers. Water-aggregate stability and clay dispersion were measured on soil aggregates less than 8 mm in diameter. Aggregate stability was measured...

  4. Weak Second Order Explicit Stabilized Methods for Stiff Stochastic Differential Equations

    KAUST Repository

    Abdulle, Assyr

    2013-01-01

    We introduce a new family of explicit integrators for stiff Itô stochastic differential equations (SDEs) of weak order two. These numerical methods belong to the class of one-step stabilized methods with extended stability domains and do not suffer from the step size reduction faced by standard explicit methods. The family is based on the standard second order orthogonal Runge-Kutta-Chebyshev (ROCK2) methods for deterministic problems. The convergence, meansquare, and asymptotic stability properties of the methods are analyzed. Numerical experiments, including applications to nonlinear SDEs and parabolic stochastic partial differential equations are presented and confirm the theoretical results. © 2013 Society for Industrial and Applied Mathematics.

  5. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  6. Agglomeration of Celecoxib by Quasi Emulsion Solvent Diffusion Method: Effect of Stabilizer

    Directory of Open Access Journals (Sweden)

    Maryam Maghsoodi

    2016-12-01

    Full Text Available Purpose: The quasi-emulsion solvent diffusion (QESD has evolved into an effective technique to manufacture agglomerates of API crystals. Although, the proposed technique showed benefits, such as cost effectiveness, that is considerably sensitive to the choice of a stabilizer, which agonizes from a absence of systemic understanding in this field. In the present study, the combination of different solvents and stabilizers were compared to investigate any connections between the solvents and stabilizers. Methods: Agglomerates of celecoxib were prepared by QESD method using four different stabilizers (Tween 80, HPMC, PVP and SLS and three different solvents (methyl acetate, ethyl acetate and isopropyl acetate. The solid state of obtained particles was investigated by differential scanning calorimetry (DSC and Fourier transform infrared (FT-IR spectroscopy. The agglomerated were also evaluated in term of production yield, distribution of particles and dissolution behavior. Results: The results showed that the effectiveness of stabilizer in terms of particle size and particle size distribution is specific to each solvent candidate. A stabilizer with a lower HLB value is preferred which actually increased its effectiveness with the solvent candidates with higher lipophilicity. HPMC appeared to be the most versatile stabilizer because it showed a better stabilizing effect compared to other stabilizers in all solvents used. Conclusion: This study demonstrated that the efficiency of stabilizers in forming the celecoxib agglomerates by QESD was influenced by the HLB of the stabilizer and lipophilicity of the solvents.

  7. Digital Image Stabilization Method Based on Variational Mode Decomposition and Relative Entropy

    Directory of Open Access Journals (Sweden)

    Duo Hao

    2017-11-01

    Full Text Available Cameras mounted on vehicles frequently suffer from image shake due to the vehicles’ motions. To remove jitter motions and preserve intentional motions, a hybrid digital image stabilization method is proposed that uses variational mode decomposition (VMD and relative entropy (RE. In this paper, the global motion vector (GMV is initially decomposed into several narrow-banded modes by VMD. REs, which exhibit the difference of probability distribution between two modes, are then calculated to identify the intentional and jitter motion modes. Finally, the summation of the jitter motion modes constitutes jitter motions, whereas the subtraction of the resulting sum from the GMV represents the intentional motions. The proposed stabilization method is compared with several known methods, namely, medium filter (MF, Kalman filter (KF, wavelet decomposition (MD method, empirical mode decomposition (EMD-based method, and enhanced EMD-based method, to evaluate stabilization performance. Experimental results show that the proposed method outperforms the other stabilization methods.

  8. Veriflow Campylobacter. Performance tested method 101201.

    Science.gov (United States)

    Joelsson, Adam C; Brown, Ashley S; Puri, Amrita; Keough, Martin P; Pascal, Benjamin J; Gaudioso, Zara E

    2014-01-01

    Veriflow Campylobacter is a molecular based assay for the presumptive and qualitative detection of the most common occurring foodborne Campylobacter species: C. jejuni and C. coli. The assay utilizes a PCR detection method coupled with a rapid, visual, flow-based assay that develops in 3 min post PCR amplification and requires only 24 h of non-specialized enrichment for maximum sensitivity. The Veriflow Campylobacter system eliminates the need for microaerobic chambers, gel electrophoresis or fluorophore based detection of target amplification, and does not require complex data analysis. This Performance Tested Method validation study demonstrated the ability of the Veriflow method to detect naturally occurring Campylobacterfrom chicken carcass rinsates. In the reference comparison study, Chi-square and probability of detection analyses of two unpaired studies indicated that there was no significant difference between the Veriflow Campylobacter method and the U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) reference method. There was no indication of false positive or false negative detection in the reference comparison study, and all 50 C. jejuni and C. coli strains were detected, while 35 nonspecific organisms were undetected in the exclusivity/ inclusivity study. The study results show that Veriflow Campylobacter is a sensitive, selective and robust assay for the detection of C. jejuni and C. coli in chicken carcass rinsates.

  9. Noise-abatement method for explosives testing.

    Science.gov (United States)

    Pfeifer, H E; Odell, B N; Arganbright, V E

    1980-09-01

    When Lawrence Livermore Laboratory started detonating explosives at its Site 300 test location in the sparsely populated hills east of the Laboratory, residents in neighboring areas complained of sudden loud noises. A combined literature and research study, coupled with an experimental test program, indicated the combination of air temperatures and winds at various elevations was primarily responsible for blast or sound waves being returned to the surface. To solve the noise problem, the Laboratory devised a method for determining the maximum amount of explosives that could be detonated aboveground under various atmospheric conditions without creating excessive noise in populated areas. This method for predicting explosives weight limits using pressure-distance-weight nomograms and the slope of a sound-velocity curve is described in this paper. The sound-velocity curve is computed with temperature information from the U.S. Weather Bureau and wind data from a target-acquisition radar system. By following this method, the Laboratory has been able to detonate thousands of shots without creating excessive noise in nearby communities.

  10. Numerical simulation of fluid-structure interactions with stabilized finite element method

    Science.gov (United States)

    Sváček, Petr

    2016-03-01

    This paper is interested to the interactions of the incompressible flow with a flexibly supported airfoil. The bending and the torsion modes are considered. The problem is mathematically described. The numerical method is based on the finite element method. A combination of the streamline-upwind/Petrov-Galerkin and pressure stabilizing/Petrov-Galerkin method is used for the stabilization of the finite element method. The numerical results for a three-dimensional problem of flow over an airfoil are shown.

  11. Formulation, stability testing, and analytical characterization of melatonin-based preparation for clinical trial

    Directory of Open Access Journals (Sweden)

    Samira Filali

    2017-08-01

    Full Text Available A new institutional clinical trial assessed the improvement of sleep disorders in 40 children with autism treated by immediate-release melatonin formulation in different regimens (0.5 mg, 2 mg, and 6 mg daily for one month. The objectives of present study were to (i prepare low-dose melatonin hard capsules for pediatric use controlled by two complementary methods and (ii carry out a stability study in order to determine a use-by-date. Validation of preparation process was claimed as ascertained by mass uniformity of hard capsules. Multicomponent analysis by attenuated total reflectance Fourier transformed infrared (ATR-FTIR of melatonin/microcrystalline cellulose mixture allowed to identify and quantify relative content of active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high performance liquid chromatography in 0.5 mg and 6 mg melatonin capsules was 93.6%±4.1% and 98.7%±6.9% of theoretical value, respectively. Forced degradation study showed a good separation of melatonin and its degradation products. The capability of the method was 15, confirming a risk of false negative <0.01%. Stability test and dissolution test were compliant over 18 months of storage with European Pharmacopoeia. Preparation of melatonin hard capsules was completed manually and melatonin in hard capsules was stable for 18 months, in spite of low doses of active ingredient. ATR-FTIR offers a real alternative to HPLC for quality control of high-dose melatonin hard capsules before the release of clinical batches.

  12. Identification of the period of stability in a balance test after stepping up using a simplified cumulative sum.

    Science.gov (United States)

    Safieddine, Doha; Chkeir, Aly; Herlem, Cyrille; Bera, Delphine; Collart, Michèle; Novella, Jean-Luc; Dramé, Moustapha; Hewson, David J; Duchêne, Jacques

    2017-11-01

    Falls are a major cause of death in older people. One method used to predict falls is analysis of Centre of Pressure (CoP) displacement, which provides a measure of balance quality. The Balance Quality Tester (BQT) is a device based on a commercial bathroom scale that calculates instantaneous values of vertical ground reaction force (Fz) as well as the CoP in both anteroposterior (AP) and mediolateral (ML) directions. The entire testing process needs to take no longer than 12 s to ensure subject compliance, making it vital that calculations related to balance are only calculated for the period when the subject is static. In the present study, a method is presented to detect the stabilization period after a subject has stepped onto the BQT. Four different phases of the test are identified (stepping-on, stabilization, balancing, stepping-off), ensuring that subjects are static when parameters from the balancing phase are calculated. The method, based on a simplified cumulative sum (CUSUM) algorithm, could detect the change between unstable and stable stance. The time taken to stabilize significantly affected the static balance variables of surface area and trajectory velocity, and was also related to Timed-up-and-Go performance. Such a finding suggests that the time to stabilize could be a worthwhile parameter to explore as a potential indicator of balance problems and fall risk in older people. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. 2-d Simulations of Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2004-01-01

    using both a Newton and Bingham model for characterisation of the rheological properties of the concrete. From the results, it is expected that both the slump flow and L-box can be simulated quite accurately when the model is extended to 3-d and the concrete is characterised according to the Bingham......One of the main obstacles for the further development of self-compacting concrete is to relate the fresh concrete properties to the form filling ability. Therefore, simulation of the form filling ability will provide a powerful tool in obtaining this goal. In this paper, a continuum mechanical...... approach is presented by showing initial results from 2-d simulations of the empirical test methods slump flow and L-box. This method assumes a homogeneous material, which is expected to correspond to particle suspensions e.g. concrete, when it remains stable. The simulations have been carried out when...

  14. Unconditional Stability of a Numerical Method for the Dual-Phase-Lag Equation

    Directory of Open Access Journals (Sweden)

    M. A. Castro

    2017-01-01

    Full Text Available The stability properties of a numerical method for the dual-phase-lag (DPL equation are analyzed. The DPL equation has been increasingly used to model micro- and nanoscale heat conduction in engineering and bioheat transfer problems. A discretization method for the DPL equation that could yield efficient numerical solutions of 3D problems has been previously proposed, but its stability properties were only suggested by numerical experiments. In this work, the amplification matrix of the method is analyzed, and it is shown that its powers are uniformly bounded. As a result, the unconditional stability of the method is established.

  15. New Systematic CFD Methods to Calculate Static and Single Dynamic Stability Derivatives of Aircraft

    Directory of Open Access Journals (Sweden)

    Bai-gang Mi

    2017-01-01

    Full Text Available Several new systematic methods for high fidelity and reliability calculation of static and single dynamic derivatives are proposed in this paper. Angle of attack step response is used to obtain static derivative directly; then translation acceleration dynamic derivative and rotary dynamic derivative can be calculated by employing the step response motion of rate of the angle of attack and unsteady motion of pitching angular velocity step response, respectively. Longitudinal stability derivative calculations of SACCON UCAV are taken as test cases for validation. Numerical results of all cases achieve good agreement with reference values or experiments data from wind tunnel, which indicate that the proposed methods can be considered as new tools in the process of design and production of advanced aircrafts for their high efficiency and precision.

  16. PEP Support Laboratory Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2009-09-25

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-VSL-T01A and B, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in

  17. Stability estimates for hybrid coupled domain decomposition methods

    CERN Document Server

    Steinbach, Olaf

    2003-01-01

    Domain decomposition methods are a well established tool for an efficient numerical solution of partial differential equations, in particular for the coupling of different model equations and of different discretization methods. Based on the approximate solution of local boundary value problems either by finite or boundary element methods, the global problem is reduced to an operator equation on the skeleton of the domain decomposition. Different variational formulations then lead to hybrid domain decomposition methods.

  18. Thermal Stability Test of Sugar Alcohols as Phase Change Materials for Medium Temperature Energy Storage Application

    OpenAIRE

    Solé, Aran; Neumann, Hannah; Niedermaier, Sophia; Cabeza, Luisa F.; Palomo, Elena

    2014-01-01

    Sugar alcohols are potential phase change materials candidates as they present high phase change enthalpy values, are non-toxic and low cost products. Three promising sugar-alcohols were selected: D-mannitol, myo-inositol and dulcitol under high melting enthalpy and temperature criterion. Thermal cycling tests were performed to study its cycling stability which can be determining when selecting the suitable phase change material. D-mannitol and dulcitol present poor thermal stability...

  19. The Effect of Spinal Tap Test on Different Sensory Modalities of Postural Stability in Idiopathic Normal Pressure Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Katrin Abram

    2016-09-01

    Full Text Available Background/Aims: Postural instability in patients with normal pressure hydrocephalus (NPH is a most crucial symptom leading to falls with secondary complications. The aim of the current study was to evaluate the therapeutic effect of spinal tap on postural stability in these patients. Methods: Seventeen patients with clinical symptoms of NPH were examined using gait scale, computerized dynamic posturography (CDP, and neuropsychological assessment. Examinations were done before and after spinal tap test. Results: The gait score showed a significant improvement 24 h after spinal tap test in all subtests and in the sum score (p Conclusion: Postural stability in NPH is predominantly affected by deficient vestibular functions, which did not improve after spinal tap test. Conditions which improved best were mainly independent from visual control and are based on proprioceptive functions.

  20. Vortex flow in a torus - a method for arc stabilization

    International Nuclear Information System (INIS)

    Polman, R.W.

    1976-08-01

    Experiments on ring vortices inside a torus and experiments on semi-toroidal arcs stabilized by such vortices are described. The studies were performed in two separate devices. One of the toroidal vortex chambers - 'Cogion', with R = 0.45 m and r = 0.10 m - permits the establishment of a gas flow only. In the other device - 'Tovorex', with R = 0.19 m and r = 0.04 m - it is also possible to draw a semi-toroidal arc. The measurements surprisingly show that it is possible to describe the radial distribution of the poloidal flow in terms of a plane turbulent wall jet discharging in an external stream. The velocity profile and the growth of the width of the jet are in accordance with experimental data on this subject. A different behaviour is found for the decay of the maximum velocity. The core of the flow proves to be almost stagnant; the axis of rotation is displaced outwardly with respect to the centre of the cross-section over a distance of 6 mm. In 'Tovorex' information about the rotating flow is obtained without the presence of an arc in the vortex core. The velocity profiles prove to be independent of the pressure (50-400 Torr). For experiments with arcs nitrogen is used. It has been found that the semi-toroidal DC-arc, surrounded by a continuous metal wall can be stabilized by the toroidal vortices in the experimental range30 -1 , 0.6 -1 , depends on the current and on the pressure and is independent of Usub(j) and a. Temperatures of the discharge are estimated at approximately 6000 K. The velocity profiles in both vortex chambers are obtained with a hot-wire anemometer operated at constant resistance

  1. Expansion methods for finding nonlinear stability domains of nuclear reactor models

    International Nuclear Information System (INIS)

    Yang, C.Y.; Cho, N.Z.

    1992-01-01

    Two constructive methods for estimating asymptotic stability domains of nonlinear reactor models are described in this paper: Method A based on expansion of a Lyapunov function and Method B based on expansion of any positive definite function. The methods are established on Lyapunov's stability definitions. Method A provides a sequence of stability regions that eventually approaches the exact stability domain, but requires many expansions to obtain the entire stability region because the starting Lyapunov function usually corresponds to a small stability region and because most reactor systems are stiff. Method B requires only a positive definite function and thus it is easy to come up with a starting region. From a large starting region, the entire stability region is estimated effectively after sufficient iterations. It is particularly useful for reactor systems that are stiff. These methods are applied to several nonlinear reactor models known in the literature: one-temperature feedback model, two-temperature feedback model, and xenon dynamics model, and the results are compared. (author)

  2. Comparing Motor Control Exercise and General Exercise on Lumbo-Pelvic Stability of Chronic Nonspecific Low Back Pain Sufferers Using Endurance Stability Tests

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Shamsi

    2018-01-01

    Conclusion Though it is claimed that MCE increases spinal stability, the lack of significant difference in the results of variables between the two groups may be due to our MCE not being specific for increasing spinal stability or equal effects of both interventions on increasing spinal stability and no preference of MCE. It may also be due to poor sensitivity of our outcome measures in detecting changes in spinal stability, especially with respect to the sample size. Based on these results, it could be concluded that MCE is not more effective than GE in improving endurance core stability tests and reducing disability and pain in chronic non-specific LBP patients.

  3. A Novel Model of the Ideal Point Method Coupled with Objective and Subjective Weighting Method for Evaluation of Surrounding Rock Stability

    Directory of Open Access Journals (Sweden)

    Yingchao Wang

    2016-01-01

    Full Text Available The classification of surrounding rock stability is the critical problem in tunneling engineering. In order to decrease engineering disasters, the surrounding rock stability should be accurately evaluated. The ideal point method is applied to the classification of surrounding rock stability. Considering the complexity of surrounding rock classification, some factors such as rock uniaxial compressive strengthen, integrality coefficient of rock mass, the angle between tunnel axis and the main joint, joints condition, and seepage measurement of groundwater are selected as evaluation indices. The weight coefficients of these evaluation indices are determined by the objective and subjective weighting method, consisting with the delphi method and the information entropy theory. The objective and subjective weighting method is exact and reliable to determine the weights of evaluation indices, considering not only the expert’s experiences, but also objectivity of the field test data. A new composite model is established for evaluating the surrounding rock stability based on the ideal point method and the objective and subjective weighting method. The present model is applied to Beigu mountain tunnel in Jiangsu province, China. The result is in good agreement with practical situation of surrounding rock, which proves that the ideal point method used to classify the surrounding rock in tunnels is reasonable and effective. The present model is simple and has very strong operability, which possesses a good prospect of engineering application.

  4. Does core stability exercise improve lumbopelvic stability (through endurance tests) more than general exercise in chronic low back pain? A quasi-randomized controlled trial.

    Science.gov (United States)

    Shamsi, Mohammad Bagher; Rezaei, Mandana; Zamanlou, Mehdi; Sadeghi, Mehdi; Pourahmadi, Mohammad Reza

    2016-01-01

    The aim was to compare core stability and general exercises (GEs) in chronic low back pain (LBP) patients based on lumbopelvic stability (LPS) assessment through three endurance core stability tests. There is a controversy about preference of core stability exercise (CSE) over other types of exercise for chronic LBP. Studies which have compared these exercises used other outcomes than those related to LPS. As it is claimed that CSE enhances back stability, endurance tests for LPS were used. A 16-session CSE program and a GE program with the same duration were conducted for two groups of participants. Frequency of interventions for both groups was three times a week. Forty-three people (aged 18-60 years) with chronic non-specific LBP were alternately allocated to core stability (n = 22) or GE group (n = 21) when admitted. The primary outcomes were three endurance core stability tests including: (1) trunk flexor; (2) trunk extensor; and (3) side bridge tests. Secondary outcomes were disability and pain. Measurements were taken at baseline and the end of the intervention. After the intervention, test times increased and disability and pain decreased within groups. There was no significant difference between two groups in increasing test times (p = 0.23 to p = 0.36) or decreasing disability (p = 0.16) and pain (p = 0.73). CSE is not more effective than GE for improving endurance core stability tests and reducing disability and pain in chronic non-specific LBP patients.

  5. A Stabilized Incompressible SPH Method by Relaxing the Density Invariance Condition

    Directory of Open Access Journals (Sweden)

    Mitsuteru Asai

    2012-01-01

    Full Text Available A stabilized Incompressible Smoothed Particle Hydrodynamics (ISPH is proposed to simulate free surface flow problems. In the ISPH, pressure is evaluated by solving pressure Poisson equation using a semi-implicit algorithm based on the projection method. Even if the pressure is evaluated implicitly, the unrealistic pressure fluctuations cannot be eliminated. In order to overcome this problem, there are several improvements. One is small compressibility approach, and the other is introduction of two kinds of pressure Poisson equation related to velocity divergence-free and density invariance conditions, respectively. In this paper, a stabilized formulation, which was originally proposed in the framework of Moving Particle Semi-implicit (MPS method, is applied to ISPH in order to relax the density invariance condition. This formulation leads to a new pressure Poisson equation with a relaxation coefficient, which can be estimated by a preanalysis calculation. The efficiency of the proposed formulation is tested by a couple of numerical examples of dam-breaking problem, and its effects are discussed by using several resolution models with different particle initial distances. Also, the effect of eddy viscosity is briefly discussed in this paper.

  6. Hover test of a full-scale hingeless helicopter rotor: Aeroelastic stability, performance and loads data. [wind tunnel tests

    Science.gov (United States)

    Peterson, R. L.; Warmbrodt, W.

    1984-01-01

    A hover test of a full-scale, hingeless rotor system was conducted in the NASA Ames 40- by 80-foot wind tunnel. The rotor was tested on the Ames rotor test apparatus. Rotor aeroelastic stability, performance, and loads at various rotational speeds and thrust coefficients were investigated. The primary objective was to determine the inplane stability characteristics of the rotor system. Rotor inplane damping data were obtained for operation between 350 and 425 rpm (design speed), and for thurst coefficients between 0.0 and 0.12. The rotor was stable for all conditions tested. At constant rotor rotational speed, a minimum inplane dampling level was obtained at a thrust coefficient approximately = 0.02. At constant rotor lift, a minimum in rotor inplane damping was measured at 400 rpm.

  7. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  8. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  9. A Method to Test Model Calibration Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ron; Polly, Ben; Neymark, Joel

    2016-08-26

    This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

  10. Frequency scanning-based stability analysis method for grid-connected inverter system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion with conside......This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion...... with consideration of the inverter nonlinearities. Small current disturbance is injected into grid-connected inverter system in a particular frequency range, and the impedance is computed according to the harmonic-frequency response using Fourier analysis, and then the stability is predicted on the basis...... of the impedance stability criterion. The stability issues of grid-connected inverters with grid-current feedback and the converter-current feedback are addressed using the proposed method. The results obtained from simulation and experiments validate the effectiveness of the method. The frequency scanning...

  11. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Several HPLC methods for estimation of ketotifen in pharmaceutical dosage form [12] and in biological fluids [13] are also reported. Stability indicating HPLC method is reported for ketotifen where drug is exposed to heat, oxidative media and UV light [14]. Various analytical methods such as spectrophotometric methods [15] ...

  12. On the comparison of semi-analytical methods for the stability analysis of delay differential equations

    Science.gov (United States)

    Tweten, Dennis J.; Lipp, Genevieve M.; Khasawneh, Firas A.; Mann, Brian P.

    2012-08-01

    This paper provides the first comparison of the semi-discretization, spectral element, and Legendre collocation methods. Each method is a technique for solving delay differential equations (DDEs) as well as determining regions of stability in the DDE parameter space. We present the necessary concepts, assumptions, and equations required to implement each method. To compare the relative performance between the methods, the convergence rate and computational time for each method is compared in three numerical studies consisting of a ship stability example, the delayed damped Mathieu equation, and a helicopter rotor control problem. For each study, we present one or more stability diagrams in the parameter space and one or more convergence plots. The spectral element method is demonstrated to have the quickest convergence rate while the Legendre collocation method requires the least computational time. The semi-discretization method on the other hand has both the slowest convergence rate and requires the most computational time.

  13. Feasibility Study of Improved Methods for Riverbank Stabilization

    Science.gov (United States)

    1964-11-01

    river bluffs. Thes e formations are Hattiesbu::g and Citronelle . Hattiesburg s a mples GSa, G36, and G501C were tested as bonding clays. Fired at cone...03. All samples were steel hard but cracked. No bloating. Shrinkage 14%. Specific gravity from l. 85 to 2. 15. Citronelle sample s 11, 96, 11 5

  14. Simulation methods with extended stability for stiff biochemical Kinetics

    Directory of Open Access Journals (Sweden)

    Rué Pau

    2010-08-01

    Full Text Available Abstract Background With increasing computer power, simulating the dynamics of complex systems in chemistry and biology is becoming increasingly routine. The modelling of individual reactions in (biochemical systems involves a large number of random events that can be simulated by the stochastic simulation algorithm (SSA. The key quantity is the step size, or waiting time, τ, whose value inversely depends on the size of the propensities of the different channel reactions and which needs to be re-evaluated after every firing event. Such a discrete event simulation may be extremely expensive, in particular for stiff systems where τ can be very short due to the fast kinetics of some of the channel reactions. Several alternative methods have been put forward to increase the integration step size. The so-called τ-leap approach takes a larger step size by allowing all the reactions to fire, from a Poisson or Binomial distribution, within that step. Although the expected value for the different species in the reactive system is maintained with respect to more precise methods, the variance at steady state can suffer from large errors as τ grows. Results In this paper we extend Poisson τ-leap methods to a general class of Runge-Kutta (RK τ-leap methods. We show that with the proper selection of the coefficients, the variance of the extended τ-leap can be well-behaved, leading to significantly larger step sizes. Conclusions The benefit of adapting the extended method to the use of RK frameworks is clear in terms of speed of calculation, as the number of evaluations of the Poisson distribution is still one set per time step, as in the original τ-leap method. The approach paves the way to explore new multiscale methods to simulate (biochemical systems.

  15. Influence of stabilizer thickness on over-current test of YBCO-coated conductors

    Science.gov (United States)

    Kwon, N. Y.; Kim, H. S.; Kim, K. L.; Yim, S. W.; Kim, H.-R.; Hyun, O.-B.; Kim, H. M.; Lee, H. G.

    2009-04-01

    The increased use of distributed power generation has led to increasingly high fault current levels. A superconducting fault current limiter (SFCL) is a potential solution to prevent the problem of short-circuit currents. YBCO-coated conductors (CCs) are one of the most promising superconducting materials for SFCLs. Most YBCO CCs have stabilizers, which play a significant role in limiting the fault current in the SFCL. Therefore, the selection of the appropriate material and the thickness of the stabilizer of the CC used for the SFCL may affect its quench/recovery characteristics. In this paper, the quench/recovery characteristics of YBCO CC tapes having stabilizers with various thicknesses were investigated. The quench/recovery test results showed that, as the thickness of the stabilizer decreased, both the final approach temperature and the recovery time decreased.

  16. An improved algorithm to determine the density of resonance states using the stabilization method

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, F.M.; Guardiola, R. [Departamento de Fisica Atomica y Nuclear, Universidad de Valencia, Burjassot, Valencia (Spain)

    1997-05-07

    By using properties of the Sturm sequences related to tridiagonal matrices we describe a very efficient algorithm to determine the density of resonance states based on the stabilization method. (author)

  17. A Comparision of Three Methods to Increase Scleral Contact Lens On-eye Stability

    Science.gov (United States)

    Ticak, Anita; Marsack, Jason D.; Koenig, Darren E.; Ravikumar, Ayeswarya; Shi, Yue; Nguyen, Lan Chi; Applegate, Raymond A.

    2015-01-01

    Purpose To: 1) quantify on-eye rotational and translational stability of three scleral contact lens stabilization methods and 2) model the variation in visual acuity when these movements occur in a wavefront-guided correction for highly aberrated eyes. Methods Three lens stabilization methods were integrated into the posterior periphery of a scleral contact lens designed at the Visual Optics Institute. For comparison, a lens with no stabilization method (rotationally symmetric posterior periphery) was designed. The lenses were manufactured and lens movements were quantified on eight eyes as the average standard deviation of the observed translations and rotations over 60 minutes of wear. In addition, the predicted changes in acuity for 5 eyes with keratoconus wearing a simulated wavefront-guided correction (full correction through the fifth order) were modeled using the measured movements. Results For each lens design, no significant differences in the translation and rotation were found between left and right eyes, and lenses behaved similarly on all subjects. All three designs with peripheral stability modifications exhibited no statistically significant differences in translation and rotation distributions of lens movement and were statistically more stable than the spherical lens in rotation. When the measured movements were used to simulate variation in visual performance, the three lenses with integrated stability methods showed a predicted average loss in acuity from the perfectly aligned condition of approximately 0.06 logMAR (3 letters), compared to the loss of over 0.14 logMAR (7 letters) for the lens with the spherical periphery. Conclusions All three stabilization methods provided superior stability, as compared to the spherical lens design. Simulations of the optical and visual performance suggest that all three stabilization designs can provide desirable results when utilized in the delivery of a wavefront-guided correction for a highly aberrated eye

  18. Treatment method for stabilization of radioactive exchange resin

    International Nuclear Information System (INIS)

    Hideo, Oni; Takashi, Miyake; Hitoshi, Miyamoto; Toshio, Funakoshi; Yuzo, Inagaki.

    1988-01-01

    This is a method for eluting radioactive nuclides from a radioactive ion exchange resin in which it has been absorbed. First, the Cs in this resin is extracted using a neutral salt solution which contains Na + . The Cs that has been transferred to the neutral salt solution is absorbed and expelled by inorganic ion exchangers. Then the Co, Fe, Mn and Sr in said resin are eluted using an acidic solution; the Co, Fe, Mn and Sr that have been transferred to the acidic solution are separated from that solution by means of a diffusion dialysis vat. This process is a unique characteristic of this ion exchange resin treatment method. 1 fig

  19. Development of Technique for Testing the Long-Term Stability of Silicon Microstrip Detectors

    International Nuclear Information System (INIS)

    Kosinov, A.V.; Maslov, N.I.; Naumov, S.V.; Ovchinnik, V.D.; Starodubtsev, A.F.; Vasiliev, G.P.; Yalovenko, V.I.; Bosisio, L.

    2006-01-01

    An automatic multi-channel set-up prototype for simultaneous testing of the Long-Term Stability (LTS) of more than ten detectors is described. The Inner Tracking System of the ALICE experiment will include about two thousand Double-sided Microstrip Detectors (DSMD). Efficient automatic measurement techniques are crucial for the LTS test, because the corresponding test procedure should be performed on each detector and requires long time, at least two days. By using special adapters for supporting and connecting the bare DSMDs, failing detectors can be screened out before module assembly, thus minimizing the cost. Automated probe stations developed for a special purpose or for microelectronics industry are used for measuring physical static DSMD characteristics and check good-to-bad elements ratio for DSMD. However, automated (or semi-automatic)test benches for studying LTS or testing DSMD long-term stability before developing a detecting module are absent

  20. Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer

    Science.gov (United States)

    Johnson, Chris

    2008-01-01

    The paper describes the specific temperature stability and control requirements for the thermal vacuum and thermal balance testing of the Aquarius Instrument at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 10' wide x 15' deep Facility 225 Thermal Vacuum chamber. The temperature control stability requirements were less than .14 C RMS thermal variation over a seven-day period. The thermal test specification also called for the ability to impose a high-resolution sinusoidal variation for all heater zones. The special requirements of the Aquarius radiometer test necessitated the construction of a multi-function test fixture and the modification of two existing heater controller racks.

  1. Effect of preparation methods on dispersion stability and electrochemical performance of graphene sheets

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Li, E-mail: chenli1981@lut.cn; Li, Na; Zhang, Mingxia; Li, Pinnan; Lin, Zhengping

    2017-05-15

    Chemical exfoliation is one of the most important strategies for preparing graphene. The aggregation of graphene sheets severely prevents graphene from exhibiting excellent properties. However, there are no attempts to investigate the effect of preparation methods on the dispersity of graphene sheets. In this study, three chemical exfoliation methods, including Hummers method, modified Hummers method, and improved method, were used to prepare graphene sheets. The influence of preparation methods on the structure, dispersion stability in organic solvents, and electrochemical properties of graphene sheets were investigated. Fourier transform infrared microscopy, Raman spectra, transmission electron microscopy, and UV–vis spectrophotometry were employed to analyze the structure of the as-prepared graphene sheets. The results showed that graphene prepared by improved method exhibits excellent dispersity and stability in organic solvents without any additional stabilizer or modifier, which is attributed to the completely exfoliation and regular structure. Moreover, cyclic voltammetric and electrochemical impedance spectroscopy measurements showed that graphene prepared by improved method exhibits superior electrochemical properties than that prepared by the other two methods. - Graphical abstract: Graphene oxides with different oxidation degree were obtained via three methods, and then graphene with different crystal structures were created by chemical reduction of exfoliated graphene oxides. - Highlights: • Graphene oxides with different oxidation degree were obtained via three oxidation methods. • The influence of oxidation methods on microstructure of graphene was investigated. • The effect of oxidation methods on dispersion stability of graphene was investigated. • The effect of oxidation methods on electrochemical properties of graphene was discussed.

  2. Effect of preparation methods on dispersion stability and electrochemical performance of graphene sheets

    International Nuclear Information System (INIS)

    Chen, Li; Li, Na; Zhang, Mingxia; Li, Pinnan; Lin, Zhengping

    2017-01-01

    Chemical exfoliation is one of the most important strategies for preparing graphene. The aggregation of graphene sheets severely prevents graphene from exhibiting excellent properties. However, there are no attempts to investigate the effect of preparation methods on the dispersity of graphene sheets. In this study, three chemical exfoliation methods, including Hummers method, modified Hummers method, and improved method, were used to prepare graphene sheets. The influence of preparation methods on the structure, dispersion stability in organic solvents, and electrochemical properties of graphene sheets were investigated. Fourier transform infrared microscopy, Raman spectra, transmission electron microscopy, and UV–vis spectrophotometry were employed to analyze the structure of the as-prepared graphene sheets. The results showed that graphene prepared by improved method exhibits excellent dispersity and stability in organic solvents without any additional stabilizer or modifier, which is attributed to the completely exfoliation and regular structure. Moreover, cyclic voltammetric and electrochemical impedance spectroscopy measurements showed that graphene prepared by improved method exhibits superior electrochemical properties than that prepared by the other two methods. - Graphical abstract: Graphene oxides with different oxidation degree were obtained via three methods, and then graphene with different crystal structures were created by chemical reduction of exfoliated graphene oxides. - Highlights: • Graphene oxides with different oxidation degree were obtained via three oxidation methods. • The influence of oxidation methods on microstructure of graphene was investigated. • The effect of oxidation methods on dispersion stability of graphene was investigated. • The effect of oxidation methods on electrochemical properties of graphene was discussed.

  3. Stability of coupled rigid body and geometrically exact rods, block diagonalization and the energy, momentum method

    OpenAIRE

    Simo, J. C.; Posbergh, T. A.; Marsden, J. E.

    1990-01-01

    This paper develops and applies the energy-momentum method to the problem of nonlinear stability of relative equilibria. The method is applied in detail to the stability analysis of uniformly rotating states of geometrically exact rod models, and a rigid body with an attached flexible appendage. Here, the flexible appendage is modeled as a geometrically exact rod capable of accommodating arbitrarily large deformations in three dimensions; including extension, shear, flexure and twist. The mod...

  4. An assessment of different atmospheric stability methods for annual atmospheric dispersion factors at a coastal site

    International Nuclear Information System (INIS)

    Bagavathsingh, A.; Rakesh, P.T.; Srinivas, C.V.; Baskaran, R.; Venkatraman, B.

    2018-01-01

    The meteorological data is used for routine radiological release consequence analysis, real time consequence assessments of accidental releases of radiological effluents and design basis accidental analysis in a nuclear plant site. For dispersion estimate, it is often required to specify the type of stability and/or turbulence conditions in which diffusion of pollutants would occur. Stability indicates the degree of turbulence and thus the atmospheric mixing. Intensity of turbulence and dispersion of pollutant releases in to the lower atmosphere are strongly dependent on the local winds as well as resistance of atmosphere to vertical mixing which is called atmospheric stability. Three different methods of atmospheric stability based on Standard deviation of wind direction (σθ), temperature gradient and Bulk Richardson (Rib) number are used to compute stability over Kalpakkam site using hourly meteorological data. All the three methods of estimating atmospheric stability are compared with M-O similarity based method. Different atmospheric stability methods were analyzed to estimate the annual average atmospheric dispersion factors at Kalpakkam coastal site for the year 2016

  5. An Impedance-Based Stability Analysis Method for Paralleled Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper analyses the stability of paralleled voltage source converters in AC distributed power systems. An impedance-based stability analysis method is presented based on the Nyquist criterion for multiloop system. Instead of deriving the impedance ratio as usual, the system stability...... of converter and the passive network can also be predicted by the Nyquist diagrams. This method is applied to evaluate the current and voltage controller interactions of converters in both grid-connected and islanded operations. Simulations and experimental results verify the effectiveness of theoretical...... analysis....

  6. A Comparison of Three Methods to Increase Scleral Contact Lens On-Eye Stability.

    Science.gov (United States)

    Ticak, Anita; Marsack, Jason D; Koenig, Darren E; Ravikumar, Ayeswarya; Shi, Yue; Nguyen, Lan Chi; Applegate, Raymond A

    2015-11-01

    To quantify on-eye rotational and translational stability of three scleral contact lens stabilization methods and to model the variation in visual acuity when these movements occur in a wavefront-guided correction for highly aberrated eyes. Three lens stabilization methods were integrated into the posterior periphery of a scleral contact lens designed at the Visual Optics Institute. For comparison, a lens with no stabilization method (rotationally symmetric posterior periphery) was designed. The lenses were manufactured and lens movements were quantified on 8 eyes as the average SD of the observed translations and rotations over 60 min of wear. In addition, the predicted changes in acuity for five eyes with keratoconus wearing a simulated wavefront-guided correction (full correction through the fifth order) were modeled using the measured movements. For each lens design, no significant differences in the translation and rotation were found between left and right eyes, and lenses behaved similarly on all subjects. All three designs with peripheral stability modifications exhibited no statistically significant differences in translation and rotation distributions of lens movement and were statistically more stable than the spherical lens in rotation. When the measured movements were used to simulate variation in visual performance, the 3 lenses with integrated stability methods showed a predicted average loss in acuity from the perfectly aligned condition of approximately 0.06 logMAR (3 letters), compared with the loss of over 0.14 logMAR (7 letters) for the lens with the spherical periphery. All three stabilization methods provided superior stability, as compared with the spherical lens design. Simulations of the optical and visual performance suggest that all three stabilization designs can provide desirable results when used in the delivery of a wavefront-guided correction for a highly aberrated eye.

  7. An Iterative, Dynamically Stabilized (IDS) Method of Data Unfolding

    CERN Document Server

    Malaescu, Bogdan

    2011-01-01

    We describe an iterative unfolding method for experimental data, making use of a regularization function. The use of this function allows one to build an improved normalization procedure for Monte Carlo spectra, unbiased by the presence of possible new structures in data. We unfold, in a dynamically stable way, data spectra which can be strongly affected by fluctuations in the background subtraction and simultaneously reconstruct structures which were not initially simulated.

  8. A new free-surface stabilization algorithm for geodynamical modelling: Theory and numerical tests

    Science.gov (United States)

    Andrés-Martínez, Miguel; Morgan, Jason P.; Pérez-Gussinyé, Marta; Rüpke, Lars

    2015-09-01

    The surface of the solid Earth is effectively stress free in its subaerial portions, and hydrostatic beneath the oceans. Unfortunately, this type of boundary condition is difficult to treat computationally, and for computational convenience, numerical models have often used simpler approximations that do not involve a normal stress-loaded, shear-stress free top surface that is free to move. Viscous flow models with a computational free surface typically confront stability problems when the time step is bigger than the viscous relaxation time. The small time step required for stability (develop strategies that mitigate the stability problem by making larger (at least ∼10 Kyr) time steps stable and accurate. Here we present a new free-surface stabilization algorithm for finite element codes which solves the stability problem by adding to the Stokes formulation an intrinsic penalization term equivalent to a portion of the future load at the surface nodes. Our algorithm is straightforward to implement and can be used with both Eulerian or Lagrangian grids. It includes α and β parameters to respectively control both the vertical and the horizontal slope-dependent penalization terms, and uses Uzawa-like iterations to solve the resulting system at a cost comparable to a non-stress free surface formulation. Four tests were carried out in order to study the accuracy and the stability of the algorithm: (1) a decaying first-order sinusoidal topography test, (2) a decaying high-order sinusoidal topography test, (3) a Rayleigh-Taylor instability test, and (4) a steep-slope test. For these tests, we investigate which α and β parameters give the best results in terms of both accuracy and stability. We also compare the accuracy and the stability of our algorithm with a similar implicit approach recently developed by Kaus et al. (2010). We find that our algorithm is slightly more accurate and stable for steep slopes, and also conclude that, for longer time steps, the optimal

  9. Stability test for amorphous materials in humidity controlled 96-well plates by near-infrared spectroscopy.

    Science.gov (United States)

    Otsuka, Makoto; Tanabe, Hideaki

    2012-03-01

    The purpose of this research is to apply near infrared spectrometry (NIR) with chemoinformetrics to predict the change of crystalline properties of indomethacin (IMC) amorphous under various levels of relative humidity storage conditions. Stability test for amorphous and meta-stable polymorphic forms was performed in humidity controlled the modified 96-well quartz plates containing various kinds of saturated salt solutions (0-100% of relative humidity (RH)) by NIR spectroscopy. Amorphous form was obtained melt product to pour into liquid nitrogen and after then ground. Samples were stored at 25°C in the 6-well plates at various levels of RH. The spectra of the powder samples were measured by the reflectance FT-NIR spectrometer. The second derivative spectra of form α showed specific absorption peaks at 4980, 6036, 7296 and 8616 cm-1 and that of form γ showed those at 5020, 5028, 7344, 7428 and 8436 cm-1. After storage at less than 50% RH, the peak intensities at 5020, 5028, 7344, 7428 and 8436 cm-1 of the amorphous solid increased with increasing of storage time. However, the peak intensity at 4980, 6036 and 7296 cm-1 increased at more than 50% RH Please check and confirm the edit. The results suggested that at lower humidity, the IMC amorphous solid transformed into form γ, but it transformed into form α at more than high humidity. It is possible that crystalline stability of the pharmaceutical preparations could be predicted by using humidity controlled 96-well plates and reflectance NIR-chemoinformetric methods.

  10. Convergence and stability of the exponential Euler method for semi-linear stochastic delay differential equations.

    Science.gov (United States)

    Zhang, Ling

    2017-01-01

    The main purpose of this paper is to investigate the strong convergence and exponential stability in mean square of the exponential Euler method to semi-linear stochastic delay differential equations (SLSDDEs). It is proved that the exponential Euler approximation solution converges to the analytic solution with the strong order [Formula: see text] to SLSDDEs. On the one hand, the classical stability theorem to SLSDDEs is given by the Lyapunov functions. However, in this paper we study the exponential stability in mean square of the exact solution to SLSDDEs by using the definition of logarithmic norm. On the other hand, the implicit Euler scheme to SLSDDEs is known to be exponentially stable in mean square for any step size. However, in this article we propose an explicit method to show that the exponential Euler method to SLSDDEs is proved to share the same stability for any step size by the property of logarithmic norm.

  11. EHPS Handling Stability Analysis of Electric Bus Based on System Identification Method

    Science.gov (United States)

    Zhang, Ni; Liu, Hai-mei; Bei, Shao-yi; Li, Bo; Zhao, Jing-bo

    2017-09-01

    Electric hydraulic assist force steering system (EHPS system) is the steering system of electric bus, this paper presents a method of EHPS handling stability analysis based on system identification method according to the handling stability of EHPS system for electric bus. The simulation model of electro-hydraulic assist force steering system EHPS is established by using the software AMESim, and making a quantitative analysis on the characteristics of the electric assist force assisted steering system, the assist force response and stability. At the same time, we study the stability of vehicle, including hunting, transient response, return experiment, the results show that the HPS and EHPS by comparing the simulation: It improves the portability, road sense, transient response and return performance after loading the system, which verifiy the effectiveness of the control strategy that improves vehicle steering performance, and it provides the basis for the optimization of control methods in the future.

  12. Comparison of model reference and map based control method for vehicle stability enhancement

    NARCIS (Netherlands)

    Baek, S.; Son, M.; Song, J.; Boo, K.; Kim, H.

    2012-01-01

    A map based controller method to improve a vehicle lateral stability is proposed in this study and compared with the conventional method, a model referenced controller. A model referenced controller to determine compensated yaw moment uses the sliding mode method, but the proposed map based

  13. An approximate method for lateral stability analysis of wall-frame ...

    Indian Academy of Sciences (India)

    MS received 10 September 2008; revised 21 October 2009; accepted 16. November 2009. Abstract. This study presents an approximate method based on the continuum approach and transfer matrix method for lateral stability analysis of buildings. In this method, the whole structure is idealized as an equivalent sandwich ...

  14. Design Method of ZMP Disturbance Observer for Walking Stabilization of Biped Robot

    Science.gov (United States)

    Sato, Tomoya; Sakaino, Sho; Ohnishi, Kouhei

    This paper proposes a design method of zero-moment point (ZMP) disturbance observer for walking stabilization of biped robots. A parameter design method for the filter required in the ZMP disturbance observer is proposed for performance improvement, and a variable compliance controller is introduced for impact reduction during landing. The validity of the proposed method was confirmed by simulations and experiments.

  15. Viability, purity, and genetic stability of entomopathogenic fungi species using different preservation methods.

    Science.gov (United States)

    Ayala-Zermeño, Miguel A; Gallou, Adrien; Berlanga-Padilla, Angélica M; Andrade-Michel, Gilda Y; Rodríguez-Rodríguez, José C; Arredondo-Bernal, Hugo C; Montesinos-Matías, Roberto

    2017-11-01

    Preservation methods for entomopathogenic fungi (EPF) require effective protocols to ensure uniform processes and to avoid alterations during storage. The aim of this study was to preserve Beauveria bassiana, Metarhizium acridum, M. anisopliae, M. rileyi, Isaria javanica, Hirsutella thompsonii, H. citriformis and Lecanicillium lecanii in mineral oil (MO), sterile water (SW), silica gel (SG), lyophilisation (L), ultracold-freezing at -70 °C, and cryopreservation at -196 °C. The viability and purity of the fungi were then verified: phenotypic characteristics were evaluated qualitatively at 6, 12 and 24 m. Genetic stability was tested by amplified fragment length polymorphisms (AFLP) analysis at 24 m. Of the eight species of EPF, three remained viable in SW, five in MO and L, six at -70 °C, seven in SG, and eight at -196 °C. No significant changes were observed in AFLP patterns at 24 m of storage. The most effective preservation methods for EPF were SG, L, -70 and -196 °C. Beauveria bassiana, M. acridum, M. anisopliae, M. rileyi and I. javanica remained stable with all methods, while the remaining species were less compatible. The optimisation of preservation methods for EPF facilitates the development of reliable protocols to ensure their inherent characteristics in culture collections. Copyright © 2017 British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  16. The Higgs boson and Top quark masses as tests of Electroweak Vacuum Stability

    Energy Technology Data Exchange (ETDEWEB)

    Masina, Isabella

    2013-04-15

    The measurements of the Higgs boson and top quark masses can be used to extrapolate the Standard Model Higgs potential at energies up to the Planck scale. Adopting a Next-to-Next-to-Leading Order renormalization procedure, we argue that electroweak vacuum stability is at present allowed, discuss the associated theoretical and experimental errors and the prospects for its future tests.

  17. Evaluation of seismic testing for quality assurance of lime-stabilized soil.

    Science.gov (United States)

    2013-08-01

    This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...

  18. Temporal Stability of Strength-Based Assessments: Test-Retest Reliability of Student and Teacher Reports

    Science.gov (United States)

    Romer, Natalie; Merrell, Kenneth W.

    2013-01-01

    This study focused on evaluating the temporal stability of self-reported and teacher-reported perceptions of students' social and emotional skills and assets. We used a test-retest reliability procedure over repeated administrations of the child, adolescent, and teacher versions of the "Social-Emotional Assets and Resilience Scales".…

  19. Comparison of genome stability in two pig breeds by using the sister chromatid exchange (SCE test

    Directory of Open Access Journals (Sweden)

    V. Barbieri

    2010-01-01

    Full Text Available The sister chromatid exchange (SCE test has been used to detect genome stability in humans (Chaganti, 1974 and the main livestock species (Ciotola et al., 2004; Di Meo et al., 2000; Di Berardino et al., 1979, and to discover DNA damage caused by a variety of natural and artificial chemical compounds (Iannuzzi et al., 1990.

  20. Eye-head stabilization mechanism for a humanoid robot tested on human inertial data

    DEFF Research Database (Denmark)

    Vannucci, Lorenzo; Falotico, Egidio; Tolu, Silvia

    2016-01-01

    they keep the image stationary on the retina. In this work we present the first complete model of eye-head stabilization based on the coordination of VCR and VOR. The model is provided with learning and adaptation capabilities based on internal models. Tests on a simulated humanoid platform replicating...

  1. Stability of one-step methods in transient nonlinear heat conduction

    International Nuclear Information System (INIS)

    Hughes, J.R.

    1977-01-01

    The purpose of the present work is to ascertain practical stability conditions for one-step methods commonly used in transient nonlinear heat conduction analyses. The class of problems considered is governed by a temporally continuous, spatially discrete system involving the capacity matrix C, conductivity matrix K, heat supply vector, temperature vector and time differenciation. In the linear case, in which K and C are constant, the stability behavior of one-step methods is well known. But in this paper the concepts of stability, appropriate to the nonlinear problem, are thoroughly discussed. They of course reduce to the usual stability criterion for the linear, constant coefficient case. However, for nonlinear problems there are differences and these ideas are of key importance in obtaining practical stability conditions. Of particular importance is a recent result which indicates that, in a sense, the trapezoidal and midpoint families are quivalent. Thus, stability results for one family may be translated into a result for the other. The main results obtained are summarized as follows. The stability behavior of the explicit Euler method in the nonlinear regime is analogous to that for linear problems. In particular, an a priori step size restriction may be determined for each time step. The precise time step restriction on implicit conditionally stable members of the trapezoidal and midpoint families is shown not to be determinable a priori. Of considerable practical significance, unconditionally stable members of the trapezoidal and midpoint families are identified

  2. 40 CFR 63.1161 - Performance testing and test methods.

    Science.gov (United States)

    2010-07-01

    ... parameter values for the minimum scrubber makeup water flow rate and, for scrubbers that operate with recirculation, the minimum recirculation water flow rate. During the emission test, each operating parameter...

  3. International geomechanical commission. Underground nuclear testing in French Polynesia: stability and hydrology issues

    International Nuclear Information System (INIS)

    1999-01-01

    The International Geomechanical Commission is an independent group of experts in rock mechanics and hydrology. This commission has carried out a study on the rocks stability and hydrology of the atolls of Mururoa and Fangataufa (French Polynesia) after the stoppage of the French underground nuclear tests (147 tests all of all, from which 6 took place in 1995 and 1996). This book presents the results of this study. (J.S.)

  4. Tracking evolution of myoglobin stability in cetaceans using experimentally calibrated computational methods that account for generic protein relaxation

    DEFF Research Database (Denmark)

    Holm, Jeppe; Dasmeh, Pouria; Kepp, Kasper Planeta

    2016-01-01

    that predicts multi-site ΔΔG as accurately as standard methods do for single-site mutations and reproduces trends in contemporary myoglobin stabilities. We then apply this new method to the study of the evolution of Mb stability in cetaceans: With both methods the main change in stability (about 1 kcal...

  5. A stability analysis method for the fuzzy controller and its application

    International Nuclear Information System (INIS)

    Han, Suk Gyu

    1994-02-01

    A method is proposed to analyze the stability of a fuzzy controller and the method is applied to a fuzzy controller developed in this work to automatically control the steam generator water level in the pressurized water reactor (PWR). The stability analysis method is devised from the relationships between the fuzzy controller and the conventional PI (Proportional and Integral) controller. The relationships are derived from the theoretical analysis and modeling of the widely used fuzzy controller having two inputs (Error, Rate) and one output with triangular type membership functions. In addition, an analyzable 9-Rule fuzzy controller is designed and computer-simulated for the automatic control of the steam generator water level in the PWR to employ the developed stability analysis method. This study shows that the stability analysis method based on the comparison of the equivalent PI gain ranges of the fuzzy controller with that of a linear PI controller provides very meaningful ideas for the design of stable fuzzy controller through the computer simulations. Therefore, the method suggested in this work can be used in a confirmatory process to check the stability of a fuzzy controller designed with two inputs (error, rate) and also the method would be used as an useful guidance to efficiently design and tune the fuzzy controller

  6. Stability of generalized Runge-Kutta methods for stiff kinetics coupled differential equations

    International Nuclear Information System (INIS)

    Aboanber, A E

    2006-01-01

    A stability and efficiency improved class of generalized Runge-Kutta methods of order 4 are developed for the numerical solution of stiff system kinetics equations for linear and/or nonlinear coupled differential equations. The determination of the coefficients required by the method is precisely obtained from the so-called equations of condition which in turn are derived by an approach based on Butcher series. Since the equations of condition are fewer in number, free parameters can be chosen for optimizing any desired feature of the process. A further related coefficient set with different values of these parameters and the region of absolute stability of the method have been introduced. In addition, the A(α) stability properties of the method are investigated. Implementing the method in a personal computer estimated the accuracy and speed of calculations and verified the good performances of the proposed new schemes for several sample problems of the stiff system point kinetics equations with reactivity feedback

  7. Stability of Exponential Euler Method for Stochastic Systems under Poisson White Noise Excitations

    Science.gov (United States)

    Li, Longsuo; Zhang, Yu

    2014-12-01

    The stability of stochastic systems under Poisson white noise excitations which based on the quantum theory is investigated in this paper. In general, the exact solution of the most of the stochastic systems with jumps is not easy to get. So it is very necessary to investigate the numerical solution of equations. On the one hand, exponential Euler method is applied to study stochastic delay differential equations, we can find the sufficient conditions for keeping mean square stability by investigating numerical method of systems. Through the comparison, we get the step-size of this method which is longer than the Euler-Maruyama method. On the other hand, mean square exponential stability of exponential Euler method for semi-linear stochastic delay differential equations under Poisson white noise excitations is confirmed.

  8. Propagation of internal errors in explicit Runge–Kutta methods and internal stability of SSP and extrapolation methods

    KAUST Repository

    Ketcheson, David I.

    2014-04-11

    In practical computation with Runge--Kutta methods, the stage equations are not satisfied exactly, due to roundoff errors, algebraic solver errors, and so forth. We show by example that propagation of such errors within a single step can have catastrophic effects for otherwise practical and well-known methods. We perform a general analysis of internal error propagation, emphasizing that it depends significantly on how the method is implemented. We show that for a fixed method, essentially any set of internal stability polynomials can be obtained by modifying the implementation details. We provide bounds on the internal error amplification constants for some classes of methods with many stages, including strong stability preserving methods and extrapolation methods. These results are used to prove error bounds in the presence of roundoff or other internal errors.

  9. Gold Nanoparticles: Synthesis, Stability Test, and Application for the Rice Growth

    OpenAIRE

    Wang, Aiwu; Ng, Hoi Pong; Xu, Yi; Li, Yuyu; Zheng, Yuhong; Yu, Jingping; Han, Fugui; Peng, Feng; Fu, Li

    2014-01-01

    In today’s science, with the use of nanotechnology, nanomaterials, which behave very differently from the bulk solid, can be made. One of the capable uses of nanomaterials is bioapplications which make good use of the specific properties of nanoparticles. However, since the nanoparticles will be used both in-vivo and in-vitro, their stability is an important issue to the scientists, concern. In this dissertation, we are going to test the stability of gold nanoparticles in a number of media in...

  10. Design and Testing of a Pulsatile Conditioning System for Dynamic Endothelialization of Polyphenol-Stabilized Tissue Engineered Heart Valves.

    Science.gov (United States)

    Sierad, Leslie Neil; Simionescu, Agneta; Albers, Christopher; Chen, Joseph; Maivelett, Jordan; Tedder, Mary Elizabeth; Liao, Jun; Simionescu, Dan T

    2010-06-01

    Heart valve tissue engineering requires biocompatible and hemocompatible scaffolds that undergo remodeling and repopulation, but that also withstand harsh mechanical forces immediately following implantation. We hypothesized that reversibly stabilized acellular porcine valves, seeded with endothelial cells and conditioned in pulsatile bioreactors would pave the way for next generations of tissue engineered heart valves (TEHVs). A novel valve conditioning system was first designed, manufactured and tested to adequately assess TEHVs. The bioreactor created proper closing and opening of valves and allowed for multiple mounting methods in sterile conditions. Porcine aortic heart valve roots were decellularized by chemical extractions and treated with penta-galloyl glucose (PGG) for stabilization. Properties of the novel scaffolds were evaluated by testing resistance to collagenase and elastase, biaxial mechanical analysis, and thermal denaturation profiles. Porcine aortic endothelial cells were seeded onto the leaflets and whole aortic roots were mounted within the dynamic pulsatile heart valve bioreactor system under physiologic pulmonary valve pressures and analyzed after 17 days for cell viability, morphology, and metabolic activity. Our tissue preparation methods effectively removed cells, including the potent α-Gal antigen, while leaving a well preserved extra-cellular matrix scaffold with adequate mechanical properties. PGG enhanced stabilization of extracellular matrix components but also showed the ability to be reversible. Engineered valve scaffolds encouraged attachment and survival of endothelial cells for extended periods and showed signs of widespread cell coverage after conditioning. Our novel approach shows promise toward development of sturdy and durable TEHVs capable of remodeling and cellular repopulation.

  11. A rapid, ensemble and free energy based method for engineering protein stabilities.

    Science.gov (United States)

    Naganathan, Athi N

    2013-05-02

    Engineering the conformational stabilities of proteins through mutations has immense potential in biotechnological applications. It is, however, an inherently challenging problem given the weak noncovalent nature of the stabilizing interactions. In this regard, we present here a robust and fast strategy to engineer protein stabilities through mutations involving charged residues using a structure-based statistical mechanical model that accounts for the ensemble nature of folding. We validate the method by predicting the absolute changes in stability for 138 experimental mutations from 16 different proteins and enzymes with a correlation of 0.65 and importantly with a success rate of 81%. Multiple point mutants are predicted with a higher success rate (90%) that is validated further by comparing meosphile-thermophile protein pairs. In parallel, we devise a methodology to rapidly engineer mutations in silico which we benchmark against experimental mutations of ubiquitin (correlation of 0.95) and check for its feasibility on a larger therapeutic protein DNase I. We expect the method to be of importance as a first and rapid step to screen for protein mutants with specific stability in the biotechnology industry, in the construction of stability maps at the residue level (i.e., hot spots), and as a robust tool to probe for mutations that enhance the stability of protein-based drugs.

  12. Stability of one-step methods in transient nonlinear heat conduction

    International Nuclear Information System (INIS)

    Hughes, J.R.

    1977-01-01

    The purpose of the present work is to ascertain practical stability conditions for one-step methods commonly used in transient nonlinear heat conduction analyses. In this paper the concepts of stability, appropriate to the nonlinear problem, are thoroughly discussed. They of course reduce to the usual stability critierion for the linear, constant coefficient case. However, for nonlinear problems there are differences and theses ideas are of key importance in obtaining practical stability conditions. Of particular importance is a recent result which indicates that, in a sense, the trapezoidal and midpoint families are equivalent. Thus, stability results for one family may be translated into a result for the other. The main results obtained are: The stability behaviour of the explicit Euler method in the nonlinear regime is analogous to that for linear problems. In particular, an a priori step size restriction may be determined for each time step. The precise time step restriction on implicit conditionally stable members of the trapezoidal and midpoint families is shown not to be determinable a priori. Of considerable practical significance, unconditionally stable members of the trapezoidal and midpoint families are identified. All notions of stability employed are motivated and defined, and their interpretations in practical computing are indicated. (Auth.)

  13. Non-Destructive Testing Methods: A Comparative Complitation Work

    OpenAIRE

    KARA, Okan; ERDAL, Hasan; ÇELİK, Hasan Hüseyin

    2017-01-01

    In thisstudy, nondestructive testing methods, which sustain safe material usage areanalyzed by doing defect analysis of material. Method that is used innondestructive testing process, need to be applicable on testing material interms of working conditions. For instance; eddy currents method can testnonferrous metals while it cannot test ferromagnetic metals because of workingconditions. Considering these conditions, defective material parts areidentified by examining chosen testing method and...

  14. 40 CFR 60.547 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... hour. Instrument calibration shall be performed by the procedure given in Method 25A using the single... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.547... Manufacturing Industry § 60.547 Test methods and procedures. (a) The test methods in appendix A to this part...

  15. Common test methods for insulating and sheathing materials of electrical cables - Part 4 Methods specific to polyethylene and polypropylene compounds. Section Two

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1990-01-01

    Gives the methods for measurement of elongation at break after pre-conditioning, for wrapping test after pre-conditioning, for wraping test after thermal ageing in air, for measurement of mass increase, for long-term stability test and for measurement of copper-catalysed oxidative degradation, which apply to polyolefin insulations.

  16. A Novel Method to Quantify Soil Aggregate Stability by Measuring Aggregate Bond Energies

    Science.gov (United States)

    Efrat, Rachel; Rawlins, Barry G.; Quinton, John N.; Watts, Chris W.; Whitmore, Andy P.

    2016-04-01

    Soil aggregate stability is a key indicator of soil quality because it controls physical, biological and chemical functions important in cultivated soils. Micro-aggregates are responsible for the long term sequestration of carbon in soil, therefore determine soils role in the carbon cycle. It is thus vital that techniques to measure aggregate stability are accurate, consistent and reliable, in order to appropriately manage and monitor soil quality, and to develop our understanding and estimates of soil as a carbon store to appropriately incorporate in carbon cycle models. Practices used to assess the stability of aggregates vary in sample preparation, operational technique and unit of results. They use proxies and lack quantification. Conflicting results are therefore drawn between projects that do not provide methodological or resultant comparability. Typical modern stability tests suspend aggregates in water and monitor fragmentation upon exposure to an un-quantified amount of ultrasonic energy, utilising a laser granulometer to measure the change in mean weight diameter. In this project a novel approach has been developed based on that of Zhu et al., (2009), to accurately quantify the stability of aggregates by specifically measuring their bond energies. The bond energies are measured operating a combination of calorimetry and a high powered ultrasonic probe, with computable output function. Temperature change during sonication is monitored by an array of probes which enables calculation of the energy spent heating the system (Ph). Our novel technique suspends aggregates in heavy liquid lithium heteropolytungstate, as opposed to water, to avoid exposing aggregates to an immeasurable disruptive energy source, due to cavitation, collisions and clay swelling. Mean weight diameter is measured by a laser granulometer to monitor aggregate breakdown after successive periods of calculated ultrasonic energy input (Pi), until complete dispersion is achieved and bond

  17. Continuous anneal method for characterizing the thermal stability of ultraviolet Bragg gratings

    DEFF Research Database (Denmark)

    Rathje, Jacob; Kristensen, Martin; Pedersen, Jens Engholm

    2000-01-01

    We present a new method for determining the long-term stability of UV-induced fiber Bragg gratings. We use a continuous temperature ramp method in which systematic variation of the ramp speed probes both the short- and long-term stability. Results are obtained both for gratings written in D2 loaded...... we resolve two separate energy distributions, suggesting that two different defects are involved. The experiments show that complicated decays originating from various energy distributions can be analyzed with this continuous isochronal anneal method. The results have both practical applications...

  18. Stability of fruit quality traits in diverse watermelon cultivars tested in multiple environments

    Science.gov (United States)

    Dia, Mahendra; Wehner, Todd C; Perkins-Veazie, Penelope; Hassell, Richard; Price, Daniel S; Boyhan, George E; Olson, Stephen M; King, Stephen R; Davis, Angela R; Tolla, Gregory E; Bernier, Jerome; Juarez, Benito

    2016-01-01

    Lycopene is a naturally occurring red carotenoid compound that is found in watermelon. Lycopene has antioxidant properties. Lycopene content, sugar content and hollowheart resistance are subject to significant genotype×environment interaction (G×E), which makes breeding for these fruit quality traits difficult. The objectives of this study were to (i) evaluate the influence of years and locations on lycopene content, sugar content and hollowheart resistance for a set of watermelon genotypes, and (ii) identify genotypes with high stability for lycopene, sugar, and hollowheart resistance. A diverse set of 40 genotypes was tested over 3 years and 8 locations across the southern United States in replicated, multi-harvest trials. Lycopene was tested in a subset of 10 genotypes. Data were analyzed using univariate and multivariate stability statistics (BLUP-GGE biplot) using SASGxE and RGxE programs. There were strong effects of environment as well as G×E interaction on watermelon quality traits. On the basis of stability measures, genotypes were classified as stable or unstable for each quality trait. 'Crimson Sweet' is an inbred line with high quality trait performance as well as trait stability. 'Stone Mountain', 'Tom Watson', 'Crimson Sweet' and 'Minilee' were among the best genotypes for lycopene content, sugar content and hollowheart resistance. We developed a stability chart based on marketable yield and average ranking generated from different stability measures for yield attributes and quality traits. The chart will assist in choosing parents for improvement of watermelon cultivars. See http://cuke.hort.ncsu.edu/cucurbit/wmelon/wmelonmain.html. PMID:28066557

  19. Lubricant Test Methods for Sheet Metal Forming

    DEFF Research Database (Denmark)

    Bay, Niels; Olsson, David Dam; Andreasen, Jan Lasson

    2008-01-01

    Sheet metal forming of tribologically difficult materials such as stainless steel, Al-alloys and Ti-alloys or forming in tribologically difficult operations like ironing, punching or deep drawing of thick plate requires often use of environmentally hazardous lubricants such as chlorinated paraffin...... oils in order to avoid galling. The present paper describes a systematic research in the development of new, environmentally harmless lubricants focusing on the lubricant testing aspects. A system of laboratory tests has been developed to study the lubricant performance under the very varied conditions...... appearing in different sheet forming operations such as stretch forming, deep drawing, ironing and punching. The laboratory tests have been especially designed to model the conditions in industrial production. Application of the tests for evaluating new lubricants before introducing them in production has...

  20. True Stability of Lubricants Determined Using the Ball-on-Disk Test

    Directory of Open Access Journals (Sweden)

    Angela Maria Tortora

    2016-01-01

    Full Text Available True stability of lubricants can be determined when there is minimum change in the contact area and also the intervention of wear debris in the contact zone. Here, we have used the ball-on-disk instrument with the migrating point contact, that is, relative motion between the ball and disk condition to fix the contact area and minimize the wear debris at the contact zone. The jump in the friction coefficient indicates the film failure, which appeared earlier for the motor oil 5W30 compared to 5W40. Such profile was not recorded in absence of relative motion. Therefore, 5W40 was considered to have a better lubricant stability than 5W30. Applying the same test condition to the natural lubricants shows that glycerol has better lubricant stability than glycerol-water mixture. Superior true lubricant stability by glycerol and 5W40 can be related to its high viscosity. However, they were less wear resistant compared to low viscosity lubricants like 5W30 and glycerol-water. We suspect the role of microscopic wear debris at the contact zone for this behavior although it should have been avoided in the migrating point contact condition. Overall, ball-on-disk instrument with a migrating point contact condition is an effective technique to determine the stability of lubricants.

  1. DEVELOPING THE STABILIZED MAPPING SYSTEM FOR THE GYROCOPTER – REPORT FROM THE FIRST TESTS

    Directory of Open Access Journals (Sweden)

    J. Kolecki

    2016-06-01

    Full Text Available The LiDAR mapping carried out using gyrocopters provides a relatively cheap alternative for traditional mapping involving airplanes. The costs of the fuel and the overall maintenance are much lower when compared to planes. At the same time the flight kinematics of the gyrocopter makes it an ideal vehicle for corridor mapping. However a limited payload and a strongly limited space prevent using stabilized platforms dedicated for aerial photogrammetry. As the proper stabilization of the laser scanner during the flight is crucial in order to keep the desirable quality of the LiDAR data, it was decided to develop the prototype of the stabilized, ultra-light mapping platform that can meet the restricted requirements of the gyrocopter. The paper starts with the brief discussion of the legal and practical aspects of the LiDAR data quality, dealing mostly with the influence of the flight imperfections on the point pattern and point density. Afterwards the mapping system prototype is characterized, taking into account three main components: stabilized platform, sensors and control. Subsequently first in-flight tests are described. Though the data are still not perfect mostly due to vibrations, the stabilization provides a substantial improvement of their geometry, reducing both roll and pitch deflections.

  2. A novel method for prokaryotic promoter prediction based on DNA stability

    OpenAIRE

    Kanhere, Aditi; Bansal, Manju

    2005-01-01

    Abstract Background In the post-genomic era, correct gene prediction has become one of the biggest challenges in genome annotation. Improved promoter prediction methods can be one step towards developing more reliable ab initio gene prediction methods. This work presents a novel prokaryotic promoter prediction method based on DNA stability. Results The promoter region is less stable and hence more prone to melting as compared to other genomic regions. Our analysis shows that a method of promo...

  3. An innovative method for ideal and resistive MHD stability analysis of tokamaks

    International Nuclear Information System (INIS)

    Tokuda, S.

    2001-01-01

    An advanced asymptotic matching method of ideal and resistive MHD stability analysis in tokamaks is reported. A solution method for the two dimensional Newcomb equation, a dispersion relation for an unstable ideal MHD mode in tokamaks and a new scheme for solving resistive MHD inner layer equations as an initial value problem are reported. (author)

  4. Approximation of the unsteady Brinkman-Forchheimer equations by the pressure stabilization method

    KAUST Repository

    Louaked, Mohammed

    2017-07-20

    In this work, we propose and analyze the pressure stabilization method for the unsteady incompressible Brinkman-Forchheimer equations. We present a time discretization scheme which can be used with any consistent finite element space approximation. Second-order error estimate is proven. Some numerical results are also given.© 2017 Wiley Periodicals, Inc. Numer Methods Partial Differential Eq, 2017

  5. An innovative method for ideal and resistive MHD stability analysis of tokamaks

    International Nuclear Information System (INIS)

    Tokuda, S.

    2001-01-01

    An advanced asymptotic matching method of ideal and resistive MHD stability analysis in tokamak is reported. The report explains a solution method of two-dimensional Newcomb equation, dispersion relation for an unstable ideal MHD mode in tokamak, and a new scheme for solving resistive MHD inner layer equations as an initial-value problem. (author)

  6. Analytical Approximation Methods for the Stabilizing Solution of the Hamilton-Jacobi Equation

    NARCIS (Netherlands)

    Sakamoto, Noboru; van der Schaft, Arjan J.

    2008-01-01

    In this paper, two methods for approximating the stabilizing solution of the Hamilton-Jacobi equation are proposed using symplectic geometry and a Hamiltonian perturbation technique as well as stable manifold theory. The first method uses the fact that the Hamiltonian lifted system of an integrable

  7. Analytical Approximation Methods for the Stabilizing Solution of the Hamilton–Jacobi Equation

    NARCIS (Netherlands)

    Sakamoto, Noboru; Schaft, Arjan J. van der

    2008-01-01

    In this paper, two methods for approximating the stabilizing solution of the Hamilton–Jacobi equation are proposed using symplectic geometry and a Hamiltonian perturbation technique as well as stable manifold theory. The first method uses the fact that the Hamiltonian lifted system of an integrable

  8. A new method of stabilizing zygomatic complex and arch fractures. a ...

    African Journals Online (AJOL)

    Background: Antral packing cannot support fractures of the zygomatic arch properly because of the position, therefore the aim of this report was to document a new method by which both the zygomatic bone and arch can be stabilized. Method and Materials: Iodine soaked gauze was placed in the subzygomatic space ...

  9. Leak test method and test device for iodine filter

    International Nuclear Information System (INIS)

    Fukasawa, Tetsuo; Funabashi, Kiyomi; Miura, Noboru; Miura, Eiichi.

    1995-01-01

    An air introduction device which can change a humidity is disposed upstream of an iodine filter to be tested, and a humidity measuring device is disposed downstream of the iodine filter respectively. At first, dried air reduced with humidity is flown from the air introduction device to the iodine filter, to remove moisture content from an iodine adsorber in the iodine filter. Next, air at an increased humidity is supplied to the iodine filter. The difference between the time starting the supply of the highly humid air and the time detecting the high humidity at the humidity measuring device is measured. When the time difference is smaller than the time difference measured previously in a normal iodine filter, it shows the presence of leak in the iodine filter to be tested. With such procedures, leakage in the iodine filter which removes radioactive iodine from off-gases discharged from the radioactive material handling facilities can be detected easily by using water (steams), namely, a naturally present material. (I.N.)

  10. Formulation development and stability testing of oral morphine solution utilizing preformulation approach.

    Science.gov (United States)

    Preechagoon, Detpon; Sumyai, Viroj; Tontisirin, Khanittha; Aumpon, Sirikul; Pongjanyakul, Thaned

    2005-08-18

    Prefomulation approach utilizing the fractional-ordered randomized blocked design was employed for the formulation development and stability testing of morphine solution. Factors expecting to affect the stability of morphine were evaluated, i.e., vehicle, antioxidant, chelating agent, and pH of the solution. Eight formulations of a possible 16 were prepared according to the block design. The stability of the preparations was tested after 35 days of storage. The data of preformulation study were used for formulation development. The presence of glycerin and ethylenediamine-tetraacetic acid in the formulation, and the pH of the solution adjusted to 4, stabilized morphine. The concentration of morphine decreased drastically in the formulations containing sodium metabisulfite, and those pH adjusted to 6. After 35 days, only 65% of morphine was found in the formulation containing sodium metabisulfite and pH adjusted to 6. The results of preformulation study were used for preparing oral morphine preparations. Samples were kept in amber glass bottles and stored at 4 degrees C and 25 degrees C/75% RH for 13 months. No precipitation of the four formulations was detected. Only a decrease of odor and a small increase of pH value of the preparations (preformulation approach. They were stable more than 13 months when stored at 4 degrees C and 25 degrees C/75% RH.

  11. Multiple sample setup for testing the hydrothermal stability of adsorbents in thermal energy storage applications

    International Nuclear Information System (INIS)

    Fischer, Fabian; Laevemann, Eberhard

    2015-01-01

    Thermal energy storage based on adsorption and desorption of water on an adsorbent can achieve high energy storage densities. Many adsorbents lose adsorption capacity when operated under unfavourable hydrothermal conditions during adsorption and desorption. The stability of an adsorbent against stressing hydrothermal conditions is a key issue for its usability in adsorption thermal energy storage. We built an experimental setup that simultaneously controls the hydrothermal conditions of 16 samples arranged in a matrix of four temperatures and four water vapour pressures. This setup allows the testing of potential adsorbents between temperatures of 50 °C and 350 °C and water vapour pressures of up to 32 kPa. A measurement procedure that allows the detection of the hydrothermal stability of an adsorbent after defined time spans has been designed. We verified the functionality of the multiple sample measurements with a microporous adsorbent, a zeolite NaMSX. The hydrothermal stability of this zeolite is tested by water uptake measurements. A standard deviation lower than 1% of the 16 samples for detecting the hydrothermal stability enables setting different conditions in each sample cell. Further, we compared the water uptake measurements by measuring their adsorption isotherms with the volumetric device BELSORP Aqua 3 from Bel Japan. (paper)

  12. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  13. Strong Stability Preserving Explicit Linear Multistep Methods with Variable Step Size

    KAUST Repository

    Hadjimichael, Yiannis

    2016-09-08

    Strong stability preserving (SSP) methods are designed primarily for time integration of nonlinear hyperbolic PDEs, for which the permissible SSP step size varies from one step to the next. We develop the first SSP linear multistep methods (of order two and three) with variable step size, and prove their optimality, stability, and convergence. The choice of step size for multistep SSP methods is an interesting problem because the allowable step size depends on the SSP coefficient, which in turn depends on the chosen step sizes. The description of the methods includes an optimal step-size strategy. We prove sharp upper bounds on the allowable step size for explicit SSP linear multistep methods and show the existence of methods with arbitrarily high order of accuracy. The effectiveness of the methods is demonstrated through numerical examples.

  14. Testing and building theories: mixed methods synthesis

    OpenAIRE

    Harden, Angela

    2008-01-01

    Presentation on use of mixed methods in diverse study types, which combines the findings of ‘qualitative’ and ‘quantitative’ studies within a single systematic review, in order to address the same, overlapping or complementary review questions.

  15. Multi-frequency eddy current testing method

    International Nuclear Information System (INIS)

    Levy, R.; Gallet, G.

    1980-01-01

    Monitoring by multi-frequency eddy currents has been used since 1975 in French nuclear stations; this method applies perfectly to examinations in non-irradiated surroundings. The restrictions connected with operations in controlled zones (radioactivity) have led to the development of a delayed analysis device which in no way changes the principle of the method, but allows greater flexibility of use by reducing the volume of equipment needed and by limiting the intervention of personnel to a strict minimum [fr

  16. Stability and non-standard finite difference method of the generalized Chua's circuit

    KAUST Repository

    Radwan, Ahmed G.

    2011-08-01

    In this paper, we develop a framework to obtain approximate numerical solutions of the fractional-order Chua\\'s circuit with Memristor using a non-standard finite difference method. Chaotic response is obtained with fractional-order elements as well as integer-order elements. Stability analysis and the condition of oscillation for the integer-order system are discussed. In addition, the stability analyses for different fractional-order cases are investigated showing a great sensitivity to small order changes indicating the poles\\' locations inside the physical s-plane. The GrnwaldLetnikov method is used to approximate the fractional derivatives. Numerical results are presented graphically and reveal that the non-standard finite difference scheme is an effective and convenient method to solve fractional-order chaotic systems, and to validate their stability. © 2011 Elsevier Ltd. All rights reserved.

  17. An Novel Continuation Power Flow Method Based on Line Voltage Stability Index

    Science.gov (United States)

    Zhou, Jianfang; He, Yuqing; He, Hongbin; Jiang, Zhuohan

    2018-01-01

    An novel continuation power flow method based on line voltage stability index is proposed in this paper. Line voltage stability index is used to determine the selection of parameterized lines, and constantly updated with the change of load parameterized lines. The calculation stages of the continuation power flow decided by the angle changes of the prediction of development trend equation direction vector are proposed in this paper. And, an adaptive step length control strategy is used to calculate the next prediction direction and value according to different calculation stages. The proposed method is applied clear physical concept, and the high computing speed, also considering the local characteristics of voltage instability which can reflect the weak nodes and weak area in a power system. Due to more fully to calculate the PV curves, the proposed method has certain advantages on analysing the voltage stability margin to large-scale power grid.

  18. An innovative method for the solidification/stabilization of PAHs-contaminated soil using sulfonated oil.

    Science.gov (United States)

    Ma, Fujun; Wu, Bin; Zhang, Qian; Cui, Deshan; Liu, Qingbing; Peng, Changsheng; Li, Fasheng; Gu, Qingbao

    2018-02-15

    Stabilization/solidification (S/S) has been successfully employed in many superfund sites contaminated with organic materials. However, this method's long-term effectiveness has not been fully evaluated and the increase in soil volume following treatment is unfavorable to follow-up disposal. The present study developed a novel method for the S/S of PAHs-contaminated soil with the facilitation of sulfonated oil (SO). Adding SO significantly improved the unconfined compressive strength (UCS) values of Portland cement and activated carbon (PC-AC) treated soil samples, and the UCS values of the soil sample treated with 0.02% of SO were up to 2.3 times higher than without SO addition. When the soil was treated with PC-AC-SO, the PAHs leaching concentrations were 14%-25% of that in leachates of the control soil, and high molecular weight PAHs including benzo(a)pyrene were rarely leached. Freeze/thaw durability tests reveal that the leachability of PAHs was not influenced by freeze-thaw cycles. The UCS values of PC-AC-SO treated soil samples were 2.2-3.4 times greater than those of PC-AC treated soil samples after 12 freeze-thaw cycles. The PC-AC-SO treated soils resist disintegration better when compared to the PC-AC treated soils. The SEM micrographs reveal that the soils' compactness was significantly improved when treated with SO. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Algebraic Nonoverlapping Domain Decomposition Methods for Stabilized FEM and FV Discretizations

    Science.gov (United States)

    Barth, Timothy J.; Bailey, David (Technical Monitor)

    1998-01-01

    We consider preconditioning methods for convection dominated fluid flow problems based on a nonoverlapping Schur complement domain decomposition procedure for arbitrary triangulated domains. The triangulation is first partitioned into a number of subdomains and interfaces which induce a natural 2 x 2 partitioning of the p.d.e. discretization matrix. We view the Schur complement induced by this partitioning as an algebraically derived coarse space approximation. This avoids the known difficulties associated with the direct formation of an effective coarse discretization for advection dominated equations. By considering various approximations of the block factorization of the 2 x 2 system, we have developed a family of robust preconditioning techniques. A computer code based on these ideas has been developed and tested on the IBM SP2 using MPI message passing protocol. A number of 2-D CFD calculations will be presented for both scalar advection-diffusion equations and the Euler equations discretized using stabilized finite element and finite volume methods. These results show very good scalability of the preconditioner for various discretizations as the number of processors is increased while the number of degrees of freedom per processor is fixed.

  20. Response matrix method and its application to SCWR single channel stability analysis

    International Nuclear Information System (INIS)

    Zhao, Jiyun; Tseng, K.J.; Tso, C.P.

    2011-01-01

    To simulate the reactor system dynamic features during density wave oscillations (DWO), both the non-linear method and the linear method can be used. Although some transient information is lost through model linearization, the high computational efficiency and relatively accurate results make the linear analysis methodology attractive, especially for prediction of the onset of instability. In the linear stability analysis, the system models are simplified through linearization of the complex non-linear differential equations, and then, the linear differential equations are generally solved in the frequency domain through Laplace transformation. In this paper, a system response matrix method was introduced by directly solving the differential equations in the time domain. By using a system response matrix method, the complicated transfer function derivation, which must be done in the frequency domain method, can be avoided. Using the response matrix method, a model was developed and applied to the single channel or parallel channel type instability analyses of the typical proposed SCWR design. The sensitivity of the decay ratio (DR) to the axial mesh size was analyzed and it was found that the DR is not sensitive to mesh size once sufficient number of axial nodes is applied. To demonstrate the effects of the inlet orificing to the stability feature for the supercritical condition, the sensitivity of the stability to inlet orifice coefficient was conducted for hot channel. It is clearly shown that a higher inlet orifice coefficient will make the system more stable. The susceptibility of stability to operating parameters such as mass flow rate, power and system pressure was also performed. And the measure to improve the SCWR stability sensitivity to operating parameters was investigated. It was found that the SCWR stability sensitivity feature can be improved by carefully managing the inlet orifices and choosing proper operating parameters. (author)

  1. Measuring similarity and improving stability in biomarker identification methods applied to Fourier-transform infrared (FTIR) spectroscopy.

    Science.gov (United States)

    Trevisan, Júlio; Park, Juhyun; Angelov, Plamen P; Ahmadzai, Abdullah A; Gajjar, Ketan; Scott, Andrew D; Carmichael, Paul L; Martin, Francis L

    2014-04-01

    FTIR spectroscopy is a powerful diagnostic tool that can also derive biochemical signatures of a wide range of cellular materials, such as cytology, histology, live cells, and biofluids. However, while classification is a well-established subject, biomarker identification lacks standards and validation of its methods. Validation of biomarker identification methods is difficult because, unlike classification, there is usually no reference biomarker against which to test the biomarkers extracted by a method. In this paper, we propose a framework to assess and improve the stability of biomarkers derived by a method, and to compare biomarkers derived by different method set-ups and between different methods by means of a proposed "biomarkers similarity index". Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Environmental effects on vertebrate species richness: testing the energy, environmental stability and habitat heterogeneity hypotheses.

    Directory of Open Access Journals (Sweden)

    Zhenhua Luo

    Full Text Available BACKGROUND: Explaining species richness patterns is a central issue in biogeography and macroecology. Several hypotheses have been proposed to explain the mechanisms driving biodiversity patterns, but the causes of species richness gradients remain unclear. In this study, we aimed to explain the impacts of energy, environmental stability, and habitat heterogeneity factors on variation of vertebrate species richness (VSR, based on the VSR pattern in China, so as to test the energy hypothesis, the environmental stability hypothesis, and the habitat heterogeneity hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: A dataset was compiled containing the distributions of 2,665 vertebrate species and eleven ecogeographic predictive variables in China. We grouped these variables into categories of energy, environmental stability, and habitat heterogeneity and transformed the data into 100 × 100 km quadrat systems. To test the three hypotheses, AIC-based model selection was carried out between VSR and the variables in each group and correlation analyses were conducted. There was a decreasing VSR gradient from the southeast to the northwest of China. Our results showed that energy explained 67.6% of the VSR variation, with the annual mean temperature as the main factor, which was followed by annual precipitation and NDVI. Environmental stability factors explained 69.1% of the VSR variation and both temperature annual range and precipitation seasonality had important contributions. By contrast, habitat heterogeneity variables explained only 26.3% of the VSR variation. Significantly positive correlations were detected among VSR, annual mean temperature, annual precipitation, and NDVI, whereas the relationship of VSR and temperature annual range was strongly negative. In addition, other variables showed moderate or ambiguous relations to VSR. CONCLUSIONS/SIGNIFICANCE: The energy hypothesis and the environmental stability hypothesis were supported, whereas little

  3. Study on modulation amplitude stabilization method for PEM based on FPGA in atomic magnetometer

    Science.gov (United States)

    Wang, Qinghua; Quan, Wei; Duan, Lihong

    2017-10-01

    Atomic magnetometer which uses atoms as sensitive elements have ultra-high precision and has wide applications in scientific researches. The photoelastic modulation method based on photoelastic modulator (PEM) is used in the atomic magnetometer to detect the small optical rotation angle of a linearly polarized light. However, the modulation amplitude of the PEM will drift due to the environmental factors, which reduces the precision and long-term stability of the atomic magnetometer. Consequently, stabilizing the PEM's modulation amplitude is essential to precision measurement. In this paper, a modulation amplitude stabilization method for PEM based on Field Programmable Gate Array (FPGA) is proposed. The designed control system contains an optical setup and an electrical part. The optical setup is used to measure the PEM's modulation amplitude. The FPGA chip, with the PID control algorithm implemented in it, is used as the electrical part's micro controller. The closed loop control method based on the photoelastic modulation detection system can directly measure the PEM's modulation amplitude in real time, without increasing the additional optical devices. In addition, the operating speed of the modulation amplitude stabilization control system can be greatly improved because of the FPGA's parallel computing feature, and the PID control algorithm ensures flexibility to meet different needs of the PEM's modulation amplitude set values. The Modelsim simulation results show the correctness of the PID control algorithm, and the long-term stability of the PEM's modulation amplitude reaches 0.35% in a 3-hour continuous measurement.

  4. Linear time delay methods and stability analyses of the human spine. Effects of neuromuscular reflex response.

    Science.gov (United States)

    Franklin, Timothy C; Granata, Kevin P; Madigan, Michael L; Hendricks, Scott L

    2008-08-01

    Linear stability methods were applied to a biomechanical model of the human musculoskeletal spine to investigate effects of reflex gain and reflex delay on stability. Equations of motion represented a dynamic 18 degrees-of-freedom rigid-body model with time-delayed reflexes. Optimal muscle activation levels were identified by minimizing metabolic power with the constraints of equilibrium and stability with zero reflex time delay. Muscle activation levels and associated muscle forces were used to find the delay margin, i.e., the maximum reflex delay for which the system was stable. Results demonstrated that stiffness due to antagonistic co-contraction necessary for stability declined with increased proportional reflex gain. Reflex delay limited the maximum acceptable proportional reflex gain, i.e., long reflex delay required smaller maximum reflex gain to avoid instability. As differential reflex gain increased, there was a small increase in acceptable reflex delay. However, differential reflex gain with values near intrinsic damping caused the delay margin to approach zero. Forward-dynamic simulations of the fully nonlinear time-delayed system verified the linear results. The linear methods accurately found the delay margin below which the nonlinear system was asymptotically stable. These methods may aid future investigations in the role of reflexes in musculoskeletal stability.

  5. Exponential mean-square stability of two classes of theta Milstein methods for stochastic delay differential equations

    Science.gov (United States)

    Rouz, Omid Farkhondeh; Ahmadian, Davood; Milev, Mariyan

    2017-12-01

    This paper establishes exponential mean square stability of two classes of theta Milstein methods, namely split-step theta Milstein (SSTM) method and stochastic theta Milstein (STM) method, for stochastic differential delay equations (SDDEs). We consider the SDDEs problem under a coupled monotone condition on drift and diffusion coefficients, as well as a necessary linear growth condition on the last term of theta Milstein method. It is proved that the SSTM method with θ ∈ [0, ½] can recover the exponential mean square stability of the exact solution with some restrictive conditions on stepsize, but for θ ∈ (½, 1], we proved that the stability results hold for any stepsize. Then, based on the stability results of SSTM method, we examine the exponential mean square stability of the STM method and obtain the similar stability results to that of the SSTM method. In the numerical section the figures show thevalidity of our claims.

  6. Systematic evaluation of nondestructive testing methods

    International Nuclear Information System (INIS)

    Segal, Y.; Notea, A.; Segal, E.

    1977-01-01

    The main task of an NDT engineer is to select the best method, considering the cost-benefit value of different available systems and taking into account the special existing constraints. The aim of the paper is to suggest a tool that will enable characterization of measuring systems. The derivation of the characterization parameters and functions has to be general, i.e., suitable for all possible measuring methods, independent of their principle of operation. Quite often the properties measured during the NDT procedure are not the wanted ones, but there must be a correlation between the measured property and the performance of the product. One has to bear in mind that the ultimate choice between systems is not, in practice, just based on the mathematical optimization approach that is presented. Factors like cost-benefit, availability of trained manpower, service, real-time information, weight, volume, etc., may be crucial problems, and they may well dictate the final selection

  7. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... above the state of the art power converters. This is an unnecessary high consumption of electrical energy during charging, which not only affects the consumer financially, but also creates unnecessary load on the grid....

  8. Recrystallization of niobium stabilized ferritic stainless steel during hot rolling simulation by torsion tests

    Directory of Open Access Journals (Sweden)

    Flávia Vieira Braga

    2016-01-01

    Full Text Available The aim of this study was to investigate the effect of finishing hot rolling temperature in promoting interpass recrystallization on a Nb-stabilized AISI 430 ferritic stainless steel. Torsion tests were performed in order to simulate the Steckel mill rolling process by varying the temperature ranges of the finishing passes. Interrupted torsion test were also performed and interpass recrystallization was evaluated via optical microscopy and electron backscatter diffraction (EBSD. As a result of this work, it has been established, within the restrictions of a Steckel mill rolling schedule, which thermomechanical conditions mostly favor SRX.

  9. The stability of clay using mount Sinabung ash with unconfined compression test (uct) value

    Science.gov (United States)

    Puji Hastuty, Ika; Roesyanto; Hutauruk, Ronny; Simanjuntak, Oberlyn

    2018-03-01

    The soil has a important role as a highway’s embankment material (sub grade). Soil conditions are very different in each location because the scientifically soil is a very complex and varied material and the located on the field is very loose or very soft, so it is not suitable for construction, then the soil should be stabilized. The additive material commonly used for soil stabilization includes cement, lime, fly ash, rice husk ash, and others. This experiment is using the addition of volcanic ash. The purpose of this study was to determine the Index Properties and Compressive Strength maximum value with Unconfined Compression Test due to the addition of volcanic ash as a stabilizing agent along with optimum levels of the addition. The result showed that the original soil sample has Water Content of 14.52%; the Specific Weight of 2.64%; Liquid limit of 48.64% and Plasticity Index of 29.82%. Then, the Compressive Strength value is 1.40 kg/cm2. According to USCS classification, the soil samples categorized as the (CL) type while based on AASHTO classification, the soil samples are including as the type of A-7-6. After the soil is stabilized with a variety of volcanic ash, can be concluded that the maximum value occurs at mixture variation of 11% Volcanic Ash with Unconfined Compressive Strength value of 2.32 kg/cm2.

  10. Validation of analytical methods for the stability studies of naproxen suppositories for infant and adult use

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar

    2011-01-01

    Analytical and validating studies were performed in this paper, with a view to using them in the stability studies of the future formulations of naproxen suppositories for children and adults. The most influential factors in the naproxen stability were determined, that is, the major degradation occurred in acid medium, oxidative medium and by light action. One high-performance liquid chromatography-based method was evaluated, which proved to be adequate to quantify naproxen in suppositories and was selective against degradation products. The quantification limit was 3,480 μg, so it was valid for these studies. Additionally, the parameters specificity for stability, detection and quantification limits were evaluated for the direct semi-aqueous acid-base method, which was formerly validated for the quality control and showed satisfactory results. Nevertheless, the volumetric methods were not regarded as stability indicators; therefore, this method will be used along with the chromatographic methods of choice, that is, thin-layer chromatography and highperformance liquid chromatography, to determine the degradation products

  11. Influence of particle size and preparation methods on the physical and chemical stability of amorphous simvastatin

    DEFF Research Database (Denmark)

    Zhang, Fang; Aaltonen, Jaakko; Tian, Fang

    2009-01-01

    This study investigated the factors influencing the stability of amorphous simvastatin. Quench-cooled amorphous simvastatin in two particle size ranges, 150-180 microm (QC-big) and physical and chemical...... using DSC in order to link the physical and chemical stability with molecular mobility. Chemical stability was studied with high-performance liquid chromatography (HPLC). Results obtained from the current study revealed that the solubility of amorphous forms prepared by both methods was enhanced...... molecular mobility and higher chemical degradation than CM. Therefore, the current study demonstrated that QC and CM have obvious differences in both physical and chemical properties. It was concluded that care should be taken when choosing preparation methods for making amorphous materials. Furthermore...

  12. Stability Control of Propeller Autonomous Underwater Vehicle Based on Combined Sections Method

    Directory of Open Access Journals (Sweden)

    Qi Duo

    2015-09-01

    Full Text Available Learning from the motion principle of quadrotor, a symmetric propeller AUV, which has small size and low velocity is designed. Compared with the AUV equipped with rudders, it has better maneuverability and manipulation at low velocity. According to the Newton-Euler method, the 6 DOF kinematic model and dynamic model of the propeller AUV are established. A stability controller that consists of 3 different PID controllers is designed. It makes the depth and attitude angle as trigger conditions, and the relevant controller is chosen in different moving process. The simulation experiments simulate ideal motion state and disturbed motion state, and experiments results show that the stability controller based on combined sections method can make the best of mature technology of PID, and meet the control requirements in different stages. It has a higher respond speed and accuracy, improving the stability of the propeller AUV under the disturbance of complex ocean currents.

  13. On the Stability of the Finite Difference based Lattice Boltzmann Method

    KAUST Repository

    El-Amin, Mohamed

    2013-06-01

    This paper is devoted to determining the stability conditions for the finite difference based lattice Boltzmann method (FDLBM). In the current scheme, the 9-bit two-dimensional (D2Q9) model is used and the collision term of the Bhatnagar- Gross-Krook (BGK) is treated implicitly. The implicitness of the numerical scheme is removed by introducing a new distribution function different from that being used. Therefore, a new explicit finite-difference lattice Boltzmann method is obtained. Stability analysis of the resulted explicit scheme is done using Fourier expansion. Then, stability conditions in terms of time and spatial steps, relaxation time and explicitly-implicitly parameter are determined by calculating the eigenvalues of the given difference system. The determined conditions give the ranges of the parameters that have stable solutions.

  14. Harmonic Stability Analysis of Inverter-Fed Power Systems Using Component Connection Method

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    This paper presents a Component Connection Method (CCM)-based harmonic stability analysis for ac power-electronic-fed power systems. In the approach, the system is partitioned as individual components, including the controllers of DG units, LC filters, network impedances, and power loads...... is formulated. And the harmonic stability is assessed based on eigenvalue traces of the composite model. Simulations and experimental results are given to validate the effectiveness of the analysis method, which can be employed to assess the system harmonic stability for any combinations of system parameters....... They are first independently modeled and then assembled together based on component interconnection relationships, forming a composite system model featured with the sparse and diagonal state matrix, and thereby reducing the computational burdens. A modular modelling technique for inverter-fed power system...

  15. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  16. A novel vibration mode testing method for cylindrical resonators based on microphones.

    Science.gov (United States)

    Zhang, Yongmeng; Wu, Yulie; Wu, Xuezhong; Xi, Xiang; Wang, Jianqiu

    2015-01-16

    Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

  17. A Novel Vibration Mode Testing Method for Cylindrical Resonators Based on Microphones

    Directory of Open Access Journals (Sweden)

    Yongmeng Zhang

    2015-01-01

    Full Text Available Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

  18. Analytical method by high resolution liquid chromatography for the stability study of cloratidine syrup 0.1 %

    International Nuclear Information System (INIS)

    Torres Amaro, Leonid; Garcia Penna, Caridad M; Pardo Ruiz, Zenia

    2007-01-01

    A high resolution liquid chromatography method was validated to study the stability of cloratidine syrup 0.1 %. The calibration curve in the range from 13.6 to 3.36 μg/mL was lineal, with a coefficient of correlation equal to 0.99975. The intercept and slope statistical test was not significant. The recovery obtained was 100.2 % in the concentration range studied, and the Cochran and Student (t) tests results were not important. The variation coefficient in the repeatability study was equal to 0.41 % for 10 replications assayed, whereas in the reproducibility Fischer and Student tests were not remarkable. The method proved to be specific, lineal, accurate, and exact. (Author)

  19. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  20. Method development, validation and stability study of ritonavir in bulk and pharmaceutical dosage form by spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Anindita Behera

    2011-01-01

    Full Text Available Background: Ritonavir is a protease inhibitor and mostly used as a booster for increasing the bioavailability of other protease inhibitors like Atazanavir Sulfate and Lopinavir. Aims: Quality assessment of the new dosage form of Ritonavir i.e. tablets is very essential, so two sensitive, simple and precise methods are developed for quantification of Ritonavir in bulk and tablet dosage forms. Materials and Methods: The first method is based on first order derivative method and the second is based on area under curve method. Both the methods are validated according to international conference of harmonization (ICH guidelines. A stability study of Ritonavir is done in UV - Visible Spectrophotometer under different stress conditions recommended by ICH guidelines. Results: The absorption maximum is found to be 239nm in methanol. The absorption maximum in first method is chosen at 253.2nm, and the linearity is found between 4 - 20 ΅g/ml with coefficient of correlation value 0.9981. In the second method, the range for area under curve selected is 237 - 242nm. The linearity is found between 4 -20 ΅g/ml with coefficient of correlation value 0.9992. Conclusion: The developed methods are validated and found to be simple, rapid, precise and cost-effective. The degradation study in tablet dosage form can be used as a stability indicating assay method.

  1. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    Science.gov (United States)

    Kazanin, V. F.

    2017-09-01

    High performance stability of the ATLAS Tile Calorimeter is achieved with a procedure including a multi-step calibration. One step of the calibration is based on measurements of the response stability to laser excitation of the PMTs that are used to read out the calorimeter cells. A facility to study the performance of the PMT stability response has been operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response in order to reproduce and understand the origin of the response drifts observed with the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility and the first results obtained by testing about 30 PMTs are presented.

  2. Investigation of the Adaptability of Transient Stability Assessment Methods to Real-Time Operation

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Sommer, Stefan

    2012-01-01

    In this paper, an investigation of the adaptability of available transient stability assessment methods to real-time operation and their real-time performance is carried out. Two approaches based on Lyapunov’s method and the equal area criterion are analyzed. The results allow to determine...... the runtime of each method with respect to the number of inputs. Furthermore, it allows to identify, which method is preferable in case of changes in the power system such as the integration of distributed power resources (DER). A comparison of the performance of the analyzed methods leads to the suggestion...... that matrix reduction and time domain simulation are the most critical operations....

  3. A flexible and accurate method to estimate the mode and stability of spontaneous coordinated behaviors: The index-of-stability (IS) analysis.

    Science.gov (United States)

    Zelic, Gregory; Varoqui, Deborah; Kim, Jeesun; Davis, Chris

    2018-02-01

    Patterns of coordination result from the interaction between (at least) two oscillatory components. This interaction is typically understood by means of two variables: the mode that expresses the shape of the interaction, and the stability that is the robustness of the interaction in this mode. A potent method of investigating coordinated behaviors is to examine the extent to which patterns of coordination arise spontaneously. However, a prominent issue faced by researchers is that, to date, no standard methods exist to fairly assess the stability of spontaneous coordination. In the present study, we introduce a new method called the index-of-stability (IS) analysis. We developed this method from the phase-coupling (PC) analysis that has been traditionally used for examining locomotion-respiration coordinated systems. We compared the extents to which both methods estimate the stability of simulated coordinated behaviors. Computer-generated time series were used to simulate the coordination of two rhythmic components according to a selected mode m:n and a selected degree of stability. The IS analysis was superior to the PC analysis in estimating the stability of spontaneous coordinated behaviors, in three ways: First, the estimation of stability itself was found to be more accurate and more reliable with the IS analysis. Second, the IS analysis is not constrained by the limitations of the PC analysis. Third and last, the IS analysis offers more flexibility, and so can be adapted according to the user's needs.

  4. New method for calculations of nanostructure kinetic stability at high temperature

    Science.gov (United States)

    Fedorov, A. S.; Kuzubov, A. A.; Visotin, M. A.; Tomilin, F. N.

    2017-10-01

    A new universal method is developed for determination of nanostructure kinetic stability (KS) at high temperatures, when nanostructures can be destroyed by chemical bonds breaking due to atom thermal vibrations. The method is based on calculation of probability for any bond in the structure to stretch more than a limit value Lmax, when the bond breaks. Assuming the number of vibrations is very large and all of them are independent, using the central limit theorem, an expression for the probability of a given bond elongation up to Lmax is derived in order to determine the KS. It is shown that this expression leads to the effective Arrhenius formula, but unlike the standard transition state theory it allows one to find the contributions of different vibrations to a chemical bond cleavage. To determine the KS, only calculation of frequencies and eigenvectors of vibrational modes in the groundstate of the nanostructure is needed, while the transition states need not be found. The suggested method was tested on calculating KS of bonds in some alkanes, octene isomers and narrow graphene nanoribbons of different types and widths at the temperature T=1200 K. The probability of breaking of the C-C bond in the center of these hydrocarbons is found to be significantly higher than at the ends of the molecules. It is also shown that the KS of the octene isomers decreases when the double C˭C bond is moved to the end of the molecule, which agrees well with the experimental data. The KS of the narrowest graphene nanoribbons of different types varies by 1-2 orders of magnitude depending on the width and structure, while all of them are by several orders of magnitude less stable at high temperature than the hydrocarbons and benzene.

  5. Stability analysis of explicit entropy viscosity methods for non-linear scalar conservation equations

    KAUST Repository

    Bonito, Andrea

    2013-10-03

    We establish the L2-stability of an entropy viscosity technique applied to nonlinear scalar conservation equations. First-and second-order explicit time-stepping techniques using continuous finite elements in space are considered. The method is shown to be stable independently of the polynomial degree of the space approximation under the standard CFL condition. © 2013 American Mathematical Society.

  6. Effect of the method of processing on quality and oxidative stability ...

    African Journals Online (AJOL)

    In this study four samn samples prepared from cow milk using two processing methods (traditional T1, T2 and factory processed T3, T4) were investigated for their physico-chemical properties, fatty acids composition, oxidative stability and sensory properties. The traditionally processed samples showed a significance ...

  7. Field instrumentation, monitoring of drilled shafts for landslide stabilization and development of pertinent design method.

    Science.gov (United States)

    2010-11-01

    The design method for using a single row, spaced drilled shafts, socketed into a firm rock strata, to stabilize : an unstable slope has been developed in this research. The soil arching due to the presence of spaced : drilled shafts in a slope was ob...

  8. Strong Stability Preserving Explicit Runge--Kutta Methods of Maximal Effective Order

    KAUST Repository

    Hadjimichael, Yiannis

    2013-07-23

    We apply the concept of effective order to strong stability preserving (SSP) explicit Runge--Kutta methods. Relative to classical Runge--Kutta methods, methods with an effective order of accuracy are designed to satisfy a relaxed set of order conditions but yield higher order accuracy when composed with special starting and stopping methods. We show that this allows the construction of four-stage SSP methods with effective order four (such methods cannot have classical order four). However, we also prove that effective order five methods---like classical order five methods---require the use of nonpositive weights and so cannot be SSP. By numerical optimization, we construct explicit SSP Runge--Kutta methods up to effective order four and establish the optimality of many of them. Numerical experiments demonstrate the validity of these methods in practice.

  9. Validated stability indicating methods for determination of nitazoxanide in presence of its degradation products

    Directory of Open Access Journals (Sweden)

    Nouruddin W. Ali

    2012-04-01

    Full Text Available Three sensitive, selective and reproducible stability-indicating methods are presented for determination of nitazoxanide (NTZ, a new anti-protozoal drug, in presence of its degradation products. Method A utilizes the first derivative of ratio spectra spectrophotometry by measurement of the amplitude at 364.4 nm using one of the degradation products as a divisor. Method B is a chemometric-assisted spectrophotometry, where principal component regression (PCR and partial least squares (PLS were applied. These two approaches were successfully applied to quantify NTZ in presence of degradation products using the information included in the absorption spectra in the range 260–360 nm. Method C is based on the separation of NTZ from its degradation products followed by densitometric measurement of the bands at 254 nm. The separation was carried out on silica gel 60F254, using chloroform–methanol–ammonia solution–glacial acetic acid (95:5:1:1 by volume, pH=5.80 as a developing system. These methods are suitable as stability-indicating methods for the determination of NTZ in presence of its degradation products either in bulk powder or in pharmaceutical formulations. Statistical analysis of the results has been carried out revealing high accuracy and good precision. Keywords: Nitazoxanide, Degradation, Derivative spectrophotometry, Chemometrics, TLC-densitometry, Stability-indicating methods

  10. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  11. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  12. 16 CFR 1500.40 - Method of testing toxic substances.

    Science.gov (United States)

    2010-01-01

    ... multiple animal holder. Selected doses of liquids and solutions are introduced under the sleeve. If there... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Method of testing toxic substances. 1500.40... testing toxic substances. The method of testing the toxic substances referred to in § 1500.3(c) (1)(ii)(C...

  13. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  14. II-Θ Method: a new method for the stability assessment of crack growth

    International Nuclear Information System (INIS)

    Suo, X.Z.; Combescure, A.

    1989-01-01

    Based on the continuum mechanics model, thereinafter is performed a mathematical formulation for the second derivatives of potential energy with respect to crack length in the framework of linear elasticity, in order to analyse the stability of a cracked system. We employ for this the perturbation domain technique with Lagrange coordinate; this leads to an explicit expression of the second derivatives which is particularly well amenable to the numerical computations. In the final section the second derivative is shown to be equal to a path independent integral termed D-integral

  15. Eigenvalue-based harmonic stability analysis method in inverter-fed power systems

    OpenAIRE

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2015-01-01

    This paper presents an eigenvalue-based harmonic stability analysis method for inverter-fed power systems. A full-order small-signal model for a droop-controlled Distributed Generation (DG) inverter is built first, including the time delay of digital control system, inner current and voltage control loops, and outer droop-based power control loop. Based on the inverter model, an overall small-signal model of a two-inverter-fed system is then established, and the eigenvalue-based stability ana...

  16. Reduction Method for Real-Time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian; Poulsen, Peter Noe

    2014-01-01

    assembling of the internal forces element by element at each equilibrium point and a strict requirement for small time steps to maintain accuracy and stability often prevents real time execution. Thus, enhanced numerical capacity is required. In the present study a basis reduction method is used...... to reformulate kinematic nonlinear equations of motion into a sum of constant matrices each multiplied by a reduced coordinate decreasing the assembling time. Furthermore the method allows for cutting off some of the higher frequency content not representing real physics decreasing the stability requirement...... of choosing a sufficient basis a composite beam and a cantilever beam including kinematic nonlinearities and exposed to harmonic loadings are analyzed. To reduce locking modes with higher order terms are included. From the analysis it is concluded that the method exhibits encouraging potential with respect...

  17. 40 CFR 63.905 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Test methods and procedures. 63.905...) National Emission Standards for Tanks-Level 1 § 63.905 Test methods and procedures. (a) Procedure for...

  18. 40 CFR 63.945 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... criteria of Method 21 of 40 CFR part 60, appendix A, except the instrument response factor criteria in... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Test methods and procedures. 63.945...) National Emission Standards for Surface Impoundments § 63.945 Test methods and procedures. (a) Procedure...

  19. 40 CFR 63.925 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Test methods and procedures. 63.925...) National Emission Standards for Containers § 63.925 Test methods and procedures. (a) Procedures for...

  20. Stability of FDG-PET Radiomics features - An integrated analysis of test-retest and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Leijenaar, Ralph T. H.; Carvalho, Sara; Rios Velazquez, Emmanuel [Dept. of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht Univ. Medical Center, Maastricht (Netherlands)] [and others

    2013-10-15

    Purpose: Besides basic measurements as maximum standardized uptake value (SUV){sub max} or SUV{sub mean} derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. 'Radiomics' features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. Methods: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50 % of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spear man's rank correlation coefficient. Results: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET

  1. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  2. Suitability of voltage stability study methods for real-time assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Vancraeyveld, Pieter

    2013-01-01

    This paper analyzes the suitability of existing methods for long-term voltage stability assessment for real-time operation. An overview of the relevant methods is followed with a comparison that takes into account the accuracy, computational efficiency and characteristics when used for security...... assessment. The results enable an evaluation of the run time of each method with respect to the number of inputs. Furthermore, the results assist in identifying which of the methods is most suitable for realtime operation in future power system with production based on fluctuating energy sources....

  3. Methods of computing steady-state voltage stability margins of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Joe Hong; Ghiocel, Scott Gordon

    2018-03-20

    In steady-state voltage stability analysis, as load increases toward a maximum, conventional Newton-Raphson power flow Jacobian matrix becomes increasingly ill-conditioned so power flow fails to converge before reaching maximum loading. A method to directly eliminate this singularity reformulates the power flow problem by introducing an AQ bus with specified bus angle and reactive power consumption of a load bus. For steady-state voltage stability analysis, the angle separation between the swing bus and AQ bus can be varied to control power transfer to the load, rather than specifying the load power itself. For an AQ bus, the power flow formulation is only made up of a reactive power equation, thus reducing the size of the Jacobian matrix by one. This reduced Jacobian matrix is nonsingular at the critical voltage point, eliminating a major difficulty in voltage stability analysis for power system operations.

  4. Modelling of the automatic stabilization system of the aircraft course by a fuzzy logic method

    Science.gov (United States)

    Mamonova, T.; Syryamkin, V.; Vasilyeva, T.

    2016-04-01

    The problem of the present paper concerns the development of a fuzzy model of the system of an aircraft course stabilization. In this work modelling of the aircraft course stabilization system with the application of fuzzy logic is specified. Thus the authors have used the data taken for an ordinary passenger plane. As a result of the study the stabilization system models were realised in the environment of Matlab package Simulink on the basis of the PID-regulator and fuzzy logic. The authors of the paper have shown that the use of the method of artificial intelligence allows reducing the time of regulation to 1, which is 50 times faster than the time when standard receptions of the management theory are used. This fact demonstrates a positive influence of the use of fuzzy regulation.

  5. Active Frequency Stabilization Method for Sensitive Applications Operating in Variable Temperature Environments

    Directory of Open Access Journals (Sweden)

    DONE, A.

    2018-02-01

    Full Text Available This article proposes a cost efficient and easy to implement frequency stabilization method orientated toward communication systems operating in an extensive temperature range, as the automotive or the aerospace applications. The proposed solution uses off-the-shelf components and it is optimized for very low power consumption. The novelty of this article is represented by the introduction of the barium strontium titanate capacitor for quartz crystal oscillator active frequency stabilization. After the design was completed, the performances were evaluated and compared to the ones of the uncompensated oscillator. Experimental results confirmed the suitability of the proposed design, achieving 35 times better frequency stability within variable temperature conditions, whereas the power consumption is maintained below 6mW.

  6. Application Study of Self-balanced Testing Method on Big Diameter Rock-socketed Piles

    Directory of Open Access Journals (Sweden)

    Qing-biao WANG

    2013-07-01

    Full Text Available Through the technological test of self-balanced testing method on big diameter rock-socketed piles of broadcasting centre building of Tai’an, this paper studies and analyzes the links of the balance position selection, the load cell production and installation, displacement sensor selection and installation, loading steps, stability conditions and determination of the bearing capacity in the process of self-balanced testing. And this paper summarizes key technology and engineering experience of self-balanced testing method of big diameter rock-socketed piles and, meanwhile, it also analyzes the difficult technical problems needed to be resolved urgently at present. Conclusion of the study has important significance to the popularization and application of self-balanced testing method and the similar projects.

  7. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  8. Usability testing: using “think aloud” method in testing cartographic ...

    African Journals Online (AJOL)

    The test method in which the paper seeks to address is the 'think aloud' method. The paper addresses how usability testing was conducted using the 'think aloud' method in testing a prototype application developed for real estate agents in visualizing buildings in 3D environment (using Virtual Reality). Journal of Science ...

  9. The Next Generation of High-Speed Dynamic Stability Wind Tunnel Testing (Invited)

    Science.gov (United States)

    Tomek, Deborah M.; Sewall, William G.; Mason, Stan E.; Szchur, Bill W. A.

    2006-01-01

    Throughout industry, accurate measurement and modeling of dynamic derivative data at high-speed conditions has been an ongoing challenge. The expansion of flight envelopes and non-conventional vehicle design has greatly increased the demand for accurate prediction and modeling of vehicle dynamic behavior. With these issues in mind, NASA Langley Research Center (LaRC) embarked on the development and shakedown of a high-speed dynamic stability test technique that addresses the longstanding problem of accurately measuring dynamic derivatives outside the low-speed regime. The new test technique was built upon legacy technology, replacing an antiquated forced oscillation system, and greatly expanding the capabilities beyond classic forced oscillation testing at both low and high speeds. The modern system is capable of providing a snapshot of dynamic behavior over a periodic cycle for varying frequencies, not just a damping derivative term at a single frequency.

  10. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  11. Method for stability analysis based on the Floquet theory and Vidyn calculations

    Energy Technology Data Exchange (ETDEWEB)

    Ganander, Hans

    2005-03-01

    This report presents the activity 3.7 of the STEM-project Aerobig and deals with aeroelastic stability of the complete wind turbine structure at operation. As a consequence of the increase of sizes of wind turbines dynamic couplings are being more important for loads and dynamic properties. The steady ambition to increase the cost competitiveness of wind turbine energy by using optimisation methods lowers design margins, which in turn makes questions about stability of the turbines more important. The main objective of the project is to develop a general stability analysis tool, based on the VIDYN methodology regarding the turbine dynamic equations and the Floquet theory for the stability analysis. The reason for selecting the Floquet theory is that it is independent of number of blades, thus can be used for 2 as well as 3 bladed turbines. Although the latter ones are dominating on the market, the former has large potential when talking about offshore large turbines. The fact that cyclic and individual blade pitch controls are being developed as a mean for reduction of fatigue also speaks for general methods as Floquet. The first step of a general system for stability analysis has been developed, the code VIDSTAB. Together with other methods, as the snap shot method, the Coleman transformation and the use of Fourier series, eigenfrequences and modes can be analysed. It is general with no restrictions on the number of blades nor the symmetry of the rotor. The derivatives of the aerodynamic forces are calculated numerically in this first version. Later versions would include state space formulations of these forces. This would also be the case for the controllers of turbine rotation speed, yaw direction and pitch angle.

  12. An iterative method for accelerated degradation testing data of smart electricity meter

    Science.gov (United States)

    Wang, Xiaoming; Xie, Jinzhe

    2017-01-01

    In order to evaluate the performance of smart electricity meter (SEM), we must spend a lot of time censoring its status. For example, if we assess to the meter stability of the SEM which needs several years at least according to the standards. So accelerated degradation testing (ADT) is a useful method to assess the performance of the SEM. As we known, the Wiener process is a prevalent method to interpret the performance degradation. This paper proposes an iterative method for ADT data of SEM. The simulation study verifies the application and superiority of the proposed model than other ADT methods.

  13. Highly efficient strong stability preserving Runge-Kutta methods with Low-Storage Implementations

    KAUST Repository

    Ketcheson, David I.

    2008-01-01

    Strong stability-preserving (SSP) Runge–Kutta methods were developed for time integration of semidiscretizations of partial differential equations. SSP methods preserve stability properties satisfied by forward Euler time integration, under a modified time-step restriction. We consider the problem of finding explicit Runge–Kutta methods with optimal SSP time-step restrictions, first for the case of linear autonomous ordinary differential equations and then for nonlinear or nonautonomous equations. By using alternate formulations of the associated optimization problems and introducing a new, more general class of low-storage implementations of Runge–Kutta methods, new optimal low-storage methods and new low-storage implementations of known optimal methods are found. The results include families of low-storage second and third order methods that achieve the maximum theoretically achievable effective SSP coefficient (independent of stage number), as well as low-storage fourth order methods that are more efficient than current full-storage methods. The theoretical properties of these methods are confirmed by numerical experiment.

  14. Probabilistic evaluation method of stability of ground and slope considering spatial randomness of soil properties

    International Nuclear Information System (INIS)

    Ohtori, Yasuki

    2004-01-01

    In the JEAG4601-1987 (Japan Electric Association Guide for earthquake resistance design), either the conventional deterministic method or probabilistic method is used for evaluating the stability of ground foundations and surrounding slopes in nuclear power plants. The deterministic method, in which the soil properties of 'mean ± coefficient x standard deviation' is adopted for the calculations, is generally used in the design stage to data. On the other hand, the probabilistic method, in which the soil properties assume to have probabilistic distributions, is stated as a future method. The deterministic method facilitates the evaluation, however, it is necessary to clarify the relation with the probabilistic method. In this paper, the relationship between the deterministic and the probabilistic methods are investigated. To do that, a simple model that can take into account the dynamic effect of structures and a simplified method for accounting the spatial randomness are proposed and used for the studies. As the results of studies, it is found that the strength of soil properties is most importation factor for the stability of ground structures and the probability below the safety factor evaluated with the soil properties of mean -1.0 x standard deviation' by the deterministic method is of much lower. (author)

  15. Developing a stability assessment method for power electronics-based microgrids

    Science.gov (United States)

    Austin, Peter M.

    Modern microgrids with microsources and energy storage are dependent on power electronics for control and regulation. Under certain circumstances power electronics can be destabilizing to the system due to an effect called negative incremental impedance. A careful review of the theory and literature on the subject is presented. This includes stability criteria for both AC and DC systems, as well as a discussion on the limitations posed by the analysis. A method to integrate stability assessment with higher-level microgrid architectural design is proposed. Crucial to this is impedance characterization of individual components, which was accomplished through simulation. DC and AC impedance measurement blocks were created in Matlab simulink to automate the process. A detailed switching-level model of a DC microgrid was implemented in simulink, including wind turbine microsource, battery storage, and three phase inverter. Maximum power point tracking (MPPT) was included to maximize the efficiency of the turbine and was implemented through three rectifier alternatives and control schemes. The stability characteristics of each was compared in the final analysis. Impedance data was collected individually from the components and used to assess stability in the system as a whole. The results included the assessment of stability, margin, and unstable operating points to demonstrate the feasibility of the proposed approach.

  16. Conceptual Approaches to Alternate Methods in Toxicological Testing

    OpenAIRE

    Alan M. Goldberg; Andrew N. Rowan

    1987-01-01

    Due to public pressure, in vivo methods of toxicity testing is being attempted to be replaced by in vitro methods, such as cell and organ culture, computer modelling and modified LD50 tests using lesser number of animals. Specifically in the case of Draize eye irritancy test using rabbits, a number of refinements have been incorporated by different workers, mainly use of a local anaesthetic which will reduce animal distress without vitiating the test results. The author recommends exploration...

  17. Dynamic stability test results on an 0.024 scale B-1 air vehicle

    Science.gov (United States)

    Beeman, R. R.

    1972-01-01

    Dynamic longitudinal and lateral-directional stability characteristics of the B-1 air vehicle were investigated in three wind tunnels at the Langley Research Center. The main rotary derivatives were obtained for an angle of attack range of -3 degrees to +16 degrees for a Mach number range of 0.2 to 2.16. Damping in roll data could not be obtained at the supersonic Mach numbers. The Langley 7 x 10 foot high speed tunnel, the 8 foot transonic pressure tunnel, and the 4 foot Unitary Plan wind tunnel were the test sites. An 0.024 scale light-weight model was used on a forced oscillation type balance. Test Reynolds number varied from 474,000/ft to 1,550,000/ft. through the Mach number range tested. The results showed that the dynamic stability characteristics of the model in pitch and roll were generally satisfactory up to an angle attack of about +6 degrees. In the wing sweep range from 15 to 25 degrees the positive damping levels in roll deteriorated rapidly above +2 degrees angle of attack. This reduction in roll damping is believed to be due to the onset of separation over the wing as stall is approached.

  18. Surrounding rock mass stability monitoring of underground caverns in a geomechanical model test using FBG sensors

    Science.gov (United States)

    Li, Yong; Zhu, Weishen; Zheng, Wenhua; He, Jianping

    2009-07-01

    Fiber Bragg Gratings (FBG) sensor is widely accepted as a structural stability device for all kinds of geomaterials by either embedding into or bonding onto the structures. The physical model in geotechnical engineering, which can accurately simulate the construction processes and the effects on the stability of underground caverns on basis of satisfying the similarity principles, is an actual physical entity. Due to a large number of restrained factors, a series of experiments are difficult to be carried out, in particular for how to obtain physical parameters during the experiments. Using the geo-mechanical model test of underground caverns in Shuangjiangkou Hydropower Station as a research object, the FBG sensors were mainly focused on and adopted to figure out the problem how to achieve the small displacements in the large-scale model test. The final experimental results show that the FBG sensor has higher measuring accuracy than other conventional sensors like strain gages and mini-extensometers. The experimental results agree well with the numerical simulation results. In the process of building the model, it's successful to embed the FBG sensors in the physical model through making a reserved pore and adding some special glue. In conclusion, FBG sensors can effectively measure the small displacement of monitoring points in the whole process of the geomechanical model test. The experimental results reveal the deformation and failure characteristics of the surrounding rock mass and make some guidance for the in-situ engineering construction.

  19. Status and applications of echinoid (phylum echinodermata) toxicity test methods

    Energy Technology Data Exchange (ETDEWEB)

    Bay, S.; Burgess, R.; Nacci, D.

    1993-01-01

    The use of echinoderms for toxicity testing has focused primarily on sea urchins and sand dollars (Strongylocentrotus purpuratus, Arbacia punctulata, Lytechinus pictus, and Dendraster excentricus, for example). The status and relative sensitivity of various test methods are described. The most frequently used test methods consist of short-term exposures of sea urchin sperm or embryos; these tests can be easily conducted at all times of the year by using species with complementary spawning cycles or laboratory conditioned populations of a single species. Data from reference toxicant and effluent toxicity tests are summarized. Information on the precision and sensitivity of echinoid test methods are limited and preclude rigorous comparisons with other test methods. The available data indicate that the sensitivity and precision of these methods are comparable to short-term chronic methods for other marine invertebrates and fish. Recent application of the sperm test in toxicity identification evaluations (TIEs) and studies of effluent toxicity decay and sediment toxicity illustrate the versatility of this rapid (10 to 60 min exposure) test method. Embryo tests typically use a 48 to 96 h exposure period and measure the occurrence of embryo malformations. Most recent applications of the embryo test have been for the assessment of sediment elutriate toxicity. Adult echinoderms are not frequently used to assess effluent or receiving water toxicity. Recent studies have had success in using the adult life stage of urchins and sand dollars to assess the effects of contaminated sediment on growth, behavior, and bioaccumulation.

  20. A Method of Partly Automated Testing of Software

    Science.gov (United States)

    Lowry, Mike; Visser, Willem; Washington, Rich; Artho, Cyrille; Goldberg, Allen; Haveland, Klaus; Pasareanu, Corina; Khurshid, Sarfraz; Roflu, Grigore

    2007-01-01

    A method of automated testing of software has been developed that provides an alternative to the conventional mostly manual approach for software testing. The method combines (1) automated generation of test cases on the basis of systematic exploration of the input domain of the software to be tested with (2) run-time analysis in which execution traces are monitored, verified against temporal-logic specifications, and analyzed by concurrency-error-detection algorithms. In this new method, the user only needs to provide the temporal logic specifications against which the software will be tested and the abstract description of the input domain.

  1. A statistical comparison of accelerated concrete testing methods

    Directory of Open Access Journals (Sweden)

    Denny Meyer

    1997-01-01

    Full Text Available Accelerated curing results, obtained after only 24 hours, are used to predict the 28 day strength of concrete. Various accelerated curing methods are available. Two of these methods are compared in relation to the accuracy of their predictions and the stability of the relationship between their 24 hour and 28 day concrete strength. The results suggest that Warm Water accelerated curing is preferable to Hot Water accelerated curing of concrete. In addition, some other methods for improving the accuracy of predictions of 28 day strengths are suggested. In particular the frequency at which it is necessary to recalibrate the prediction equation is considered.

  2. A novel method for prokaryotic promoter prediction based on DNA stability.

    Science.gov (United States)

    Kanhere, Aditi; Bansal, Manju

    2005-01-05

    In the post-genomic era, correct gene prediction has become one of the biggest challenges in genome annotation. Improved promoter prediction methods can be one step towards developing more reliable ab initio gene prediction methods. This work presents a novel prokaryotic promoter prediction method based on DNA stability. The promoter region is less stable and hence more prone to melting as compared to other genomic regions. Our analysis shows that a method of promoter prediction based on the differences in the stability of DNA sequences in the promoter and non-promoter region works much better compared to existing prokaryotic promoter prediction programs, which are based on sequence motif searches. At present the method works optimally for genomes such as that of Escherichia coli, which have near 50 % G+C composition and also performs satisfactorily in case of other prokaryotic promoters. Our analysis clearly shows that the change in stability of DNA seems to provide a much better clue than usual sequence motifs, such as Pribnow box and -35 sequence, for differentiating promoter region from non-promoter regions. To a certain extent, it is more general and is likely to be applicable across organisms. Hence incorporation of such features in addition to the signature motifs can greatly improve the presently available promoter prediction programs.

  3. Method of producing Pb-stabilized superconductor precursors and method of producing superconductor articles therefrom

    Science.gov (United States)

    Kroeger, Donald M.; Hsu, Huey S.; Brynestad, Jorulf

    1995-01-01

    Metal oxide superconductor powder precursors are prepared in an aerosol pyrolysis process. A solution of the metal cations is introduced into a furnace at 600.degree.-1000.degree. C. for 0.1 to 60 seconds. The process produces micron to submicron size powders without the usual loss of the lead stabilizer. The resulting powders have a narrow particle size distribution, a small grain size, and are readily converted to a superconducting composition upon subsequent heat treatment. The precursors are placed in a metal body deformed to form a wire or tape and heated to form a superconducting article. The fine powders permit a substantial reduction in heat treatment time, thus enabling a continuous processing of the powders into superconducting wire, tape or multifilamentary articles by the powder-in-tube process.

  4. Thermal-hydraulic stability tests for newly designed BWR rod bundle (step-III fuel type B)

    International Nuclear Information System (INIS)

    Ito, Y.; Itami, A.; Tsuda, K.; Nakamura, K.; Ishikawa, M.; Toba, A.; Omoto, A.

    2004-01-01

    The Step-III Fuel Type B is a new fuel design for high burn-up operation in BWRs in Japan. The fuel design uses a 9x9 - 9 rod bundle to accommodate the high fuel duty of high burn-up operation and a square water-channel to provide enhanced neutron moderation. The objective of this study is to confirm the thermal-hydraulic stability performance of the new fuel design by tests which simulate the parallel channel configuration of the BWR core. The stability testing was performed at the NFI test loop. The test bundle geometry used for the stability test is a 3x3 heater rod bundle which has about 1/8 of the cross section area of the full size 9x9 - 9 rod bundle. Full size heater rods were used to simulate the fuel rods. For parallel channel simulation, a bypass channel with a 6x6 - 8 heater rod bundle was connected in parallel with the 3x3 rod bundle test channel. The stability test results showed typical flow oscillation features which have been described as density wave oscillations. The stationary limit cycle oscillation extended flow amplitudes to several tens of a percent of the nominal value, during which periodic dry-out and re-wetting were observed. The test results were used for verification of a stability analysis code, which demonstrated that the stability performance of the new fuel design has been conservatively predicted. (author)

  5. Stability Analysis of Anchored Soil Slope Based on Finite Element Limit Equilibrium Method

    Directory of Open Access Journals (Sweden)

    Rui Zhang

    2016-01-01

    Full Text Available Under the condition of the plane strain, finite element limit equilibrium method is used to study some key problems of stability analysis for anchored slope. The definition of safe factor in slices method is generalized into FEM. The “true” stress field in the whole structure can be obtained by elastic-plastic finite element analysis. Then, the optimal search for the most dangerous sliding surface with Hooke-Jeeves optimized searching method is introduced. Three cases of stability analysis of natural slope, anchored slope with seepage, and excavation anchored slope are conducted. The differences in safety factor quantity, shape and location of slip surface, anchoring effect among slices method, finite element strength reduction method (SRM, and finite element limit equilibrium method are comparatively analyzed. The results show that the safety factor given by the FEM is greater and the unfavorable slip surface is deeper than that by the slice method. The finite element limit equilibrium method has high calculation accuracy, and to some extent the slice method underestimates the effect of anchor, and the effect of anchor is overrated in the SRM.

  6. Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome.

    Science.gov (United States)

    Tucci, Helga Tatiana; Martins, Jaqueline; Sposito, Guilherme de Carvalho; Camarini, Paula Maria Ferreira; de Oliveira, Anamaria Siriani

    2014-01-03

    The Close Kinetic Chain Upper Extremity Stability Test (CKCUES test) is a low cost shoulder functional test that could be considered as a complementary and objective clinical outcome for shoulder performance evaluation. However, its reliability was tested only in recreational athletes' males and there are no studies comparing scores between sedentary and active samples. The purpose was to examine inter and intrasession reliability of CKCUES Test for samples of sedentary male and female with (SIS), for samples of sedentary healthy male and female, and for male and female samples of healthy upper extremity sport specific recreational athletes. Other purpose was to compare scores within sedentary and within recreational athletes samples of same gender. A sample of 108 subjects with and without SIS was recruited. Subjects were tested twice, seven days apart. Each subject performed four test repetitions, with 45 seconds of rest between them. The last three repetitions were averaged and used to statistical analysis. Intraclass Correlation Coefficient ICC2,1 was used to assess intrasession reliability of number of touches score and ICC2,3 was used to assess intersession reliability of number of touches, normalized score, and power score. Test scores within groups of same gender also were compared. Measurement error was determined by calculating the Standard Error of the Measurement (SEM) and Minimum detectable change (MDC) for all scores. The CKCUES Test showed excellent intersession reliability for scores in all samples. Results also showed excellent intrasession reliability of number of touches for all samples. Scores were greater in active compared to sedentary, with exception of power score. All scores were greater in active compared to sedentary and SIS males and females. SEM ranged from 1.45 to 2.76 touches (based on a 95% CI) and MDC ranged from 2.05 to 3.91(based on a 95% CI) in subjects with and without SIS. At least three touches are needed to be considered a

  7. Influence of mandibular fixation method on stability of the maxillary occlusal plane after occlusal plane alteration.

    Science.gov (United States)

    Yosano, Akira; Katakura, Akira; Takaki, Takashi; Shibahara, Takahiko

    2009-05-01

    In this study, we investigated how method of mandibular fixation influenced longterm postoperative stability of the maxilla in Class III cases. In particular, we investigated change in the maxillary occlusal plane after Occlusal Plane Alteration. Therefore, we focused on change in the palatal plane to evaluate stability of the maxillary occlusal plane, as the position of the palatal plane affects the maxillary occlusal plane. This study included 16 patients diagnosed with mandibular protrusion. Alteration of the occlusal plane was achieved by clockwise rotation of the maxilla by Le Fort I osteotomy and mandibular setback was performed by bilateral sagittal split ramus osteotomy. We analyzed and examined lateral cephalometric radiographs taken at 1 month, 3 months, 6 months, and 1 year after surgery. Stability achieved by two methods of mandibular fixation was compared. In one group of patients (group S) titanium screws were used, and in the other group (group P) titanium-locking mini-plates were used. No significant displacement was recognized in group S, whereas an approximately 0.7mm upward vertical displacement was recognized in the anterior nasal spine in group P. As a result, not only the angle of the palatal plane and S-N plane, but also occlusal plane angle in group P showed a greater decrease than that in group S. The results suggest that fixing the mandible with screws yielded greater stability of the maxilla and maxillary occlusal plane than fixing the mandible with titanium plates.

  8. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha...

  9. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  10. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  11. Development and validation of stability indicating UPLC assay method for ziprasidone active pharma ingredient

    Directory of Open Access Journals (Sweden)

    Sonam Mittal

    2012-01-01

    Full Text Available Background: Ziprasidone, a novel antipsychotic, exhibits a potent highly selective antagonistic activity on D2 and 5HT2A receptors. Literature survey for ziprasidone revealed several analytical methods based on different techniques but no UPLC method has been reported so far. Aim: Aim of this research paper is to present a simple and rapid stability indicating isocratic, ultra performance liquid chromatographic (UPLC method which was developed and validated for the determination of ziprasidone active pharmaceutical ingredient. Forced degradation studies of ziprasidone were studied under acid, base, oxidative hydrolysis, thermal stress and photo stress conditions. Materials and Methods: The quantitative determination of ziprasidone drug was performed on a Supelco analytical column (100×2.1 mm i.d., 2.7 ΅m with 10 mM ammonium acetate buffer (pH: 6.7 and acetonitrile (ACN as mobile phase with the ratio (55:45-Buffer:ACN at a flow rate of 0.35 ml/ min. For UPLC method, UV detection was made at 318 nm and the run time was 3 min. Developed UPLC method was validated as per ICH guidelines. Results and Conclusion: Mild degradation of the drug substance was observed during oxidative hydrolysis and considerable degradation observed during basic hydrolysis. During method validation, parameters such as precision, linearity, ruggedness, stability, robustness, and specificity were evaluated, which remained within acceptable limits. Developed UPLC method was successfully applied for evaluating assay of Ziprasidone active Pharma ingredient.

  12. A comparison of short-term dispersion estimates resulting from various atmospheric stability classification methods

    International Nuclear Information System (INIS)

    Mitchell, A.E. Jr.

    1982-01-01

    Four methods of classifying atmospheric stability class are applied at four sites to make short-term (1-h) dispersion estimates from a ground-level source based on a model consistent with U.S. Nuclear Regulatory Commission practice. The classification methods include vertical temperature gradient, standard deviation of horizontal wind direction fluctuations (sigma theta), Pasquill-Turner, and modified sigma theta which accounts for meander. Results indicate that modified sigma theta yields reasonable dispersion estimates compared to those produced using methods of vertical temperature gradient and Pasquill-Turner, and can be considered as a potential economic alternative in establishing onsite monitoring programs. (author)

  13. Stability Test of Partially Purified Bromelain from Pineapple (Ananas comosus (L.) Merr) Core Extract in Artificial Stomach Fluid

    Science.gov (United States)

    Setiasih, S.; Adimas, A. Ch. D.; Dzikria, V.; Hudiyono, S.

    2018-01-01

    This study aimed to isolate and purify bromelain from pineapple core (Ananascomosus (L.) Merr) accompanied by a stability test of its enzyme activity in artificial gastric juice. Purification steps start with fractionation by a precipitation method were carried out stepwise using several concentration of ammonium sulfate salt, followed by dialysis prosess and ion exchange chromatography on DEAE-cellulose column. Each step of purification produced an increasing specific activity in enzyme fraction, starting with crude extract, respectively: 0.276 U/mg; 14.591 U/mg; and 16.05 U/mg. Bromelain fraction with the highest level of purity was obtained in 50-80% ammonium sulphate fraction after dialyzed in the amount of 58.15 times compared to the crude extract. Further purification of the enzyme by DEAE-cellulose column produced bromelain which had a purity level 160-fold compared to crude enzyme. The result of bromelain stability test in artificial stomach juice by milk clotting units assay bromelain fraction have proteolytic activity in clotting milk substrate. Exposing bromelain fraction in artificial stomach juice which gave the highest core bromelain proteolytic activity was achieved at estimated volume of 0.4-0.5 mL. Exposure in a period of reaction time to artificial stomach juice that contained pepsin showed relatively stable proteolytic activity in the first 4 hours.

  14. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  15. Stability Test For Sorghum Mutant Lines Derived From Induced Mutations with Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    S. Human

    2011-12-01

    Full Text Available Sorghum breeding program had been conducted at the Center for the Application of Isotopes and Radiation Technology, BATAN. Plant genetic variability was increased through induced mutations using gamma-ray irradiation. Through selection process in successive generations, some promising mutant lines had been identified to have good agronomic characteristics with high grain yield. These breeding lines were tested in multi location trials and information of the genotypic stability was obtained to meet the requirements for officially varietal release by the Ministry of Agriculture. A total of 11 sorghum lines and varieties consisting of 8 mutant lines derived from induced mutations (B-100, B-95, B-92, B-83, B-76, B-75, B-69 and Zh-30 and 3 control varieties (Durra, UPCA-S1 and Mandau were included in the experiment. All materials were grown in 10 agro-ecologically different locations namely Gunungkidul, Bantul, Citayam, Garut, Lampung, Bogor, Anyer, Karawaci, Cianjur and Subang. In each location, the local adaptability test was conducted by randomized block design with 3 replications. Data of grain yield was used for evaluating genotypic stability using AMMI approach. Results revealed that sorghum mutation breeding had generated 3 mutant lines (B-100, B-76 and Zh-30 exhibiting grain yield significantly higher than the control varieties. These mutant lines were genetically stable in all locations so that they would be recommended for official release as new sorghum varieties to the Ministry of Agriculture

  16. Ultrasonic, Molecular and Mechanical Testing Diagnostics in Natural Fibre Reinforced, Polymer-Stabilized Earth Blocks

    Directory of Open Access Journals (Sweden)

    C. Galán-Marín

    2013-01-01

    Full Text Available The aim of this research study was to evaluate the influence of utilising natural polymers as a form of soil stabilization, in order to assess their potential for use in building applications. Mixtures were stabilized with a natural polymer (alginate and reinforced with wool fibres in order to improve the overall compressive and flexural strength of a series of composite materials. Ultrasonic pulse velocity (UPV and mechanical strength testing techniques were then used to measure the porous properties of the manufactured natural polymer-soil composites, which were formed into earth blocks. Mechanical tests were carried out for three different clays which showed that the polymer increased the mechanical resistance of the samples to varying degrees, depending on the plasticity index of each soil. Variation in soil grain size distributions and Atterberg limits were assessed and chemical compositions were studied and compared. X-ray diffraction (XRD, X-ray fluorescence spectroscopy (XRF, and energy dispersive X-ray fluorescence (EDXRF techniques were all used in conjunction with qualitative identification of the aggregates. Ultrasonic wave propagation was found to be a useful technique for assisting in the determination of soil shrinkage characteristics and fibre-soil adherence capacity and UPV results correlated well with the measured mechanical properties.

  17. Arsenic stability in arsenopyrite-rich cemented paste backfills: a leaching test-based assessment.

    Science.gov (United States)

    Coussy, Samuel; Benzaazoua, Mostafa; Blanc, Denise; Moszkowicz, Pierre; Bussière, Bruno

    2011-01-30

    Arsenic (As) is a toxicant in tailings from sulphur deposits. It represents an environmental risk because of its high solubility. Tailings can be mixed with water (typically 25%) and a low proportion of hydraulic binder (3-7%) to produce a cemented paste backfill (CPB), stored in underground mine openings. CPB is a tailings storage technique, but it could also provide environmental advantages by stabilization of polluting elements such as As. Tailings from Casa Berardi mine (QC, Canada) contain As (3800 ppm), mainly in arsenopyrite form. For this study, three different CPBs were synthesized in laboratory using Casa Berardi tailings and three different binders. These pastes were submitted to various leaching tests after 28 days of curing. The results indicate that As is released at higher concentration for a fly ash-based CPB than for slag- and Portland cement-based CPB. However, at lower pH, As is better stabilized in fly ash-based samples. These differences can be explained by a variation of solubility of As-compounds in each CPB. Several mechanisms of As release occur, as diffusion and/or dissolution/precipitation. The accelerated weathering test results show that sulphide reactivity is buffered by the neutralizing minerals contained in CPB, and influence the As release behaviour by decreasing the oxidation of As-bearing sulphides. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Testing Single and Combinations of Amendments for Stabilization of Metals in Contrasting Extremely Contaminated Soils

    Directory of Open Access Journals (Sweden)

    Siebielec G.

    2013-04-01

    Full Text Available Metals can be stabilized by soil amendments that increase metals adsorption or alter their chemical forms. Such treatments may limit the risk related to the contamination through reduction of metal transfer to the food chain (reduction of metal uptake by plants and its availability to soil organisms and metals migration within the environment. There is a need for experiments comparing various soil amendments available at reasonable amounts under similar environmental conditions. The other question is whether all components of soil environment or soil functions are similarly protected after remediation treatment. We conducted a series of pot studies to test some traditional and novel amendments and their combinations. The treatments were tested for several highly Zn/Cd/Pb contaminated soils. Among traditional amendments composts were the most effective – they ensured plant growth, increased soil microbial activity, reduced Cd in earthworms, reduced Pb bioaccessibility and increased share of unavailable forms of Cd and Pb.

  19. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-06-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

  20. Fisher matrix forecasts for astrophysical tests of the stability of the fine-structure constant

    Directory of Open Access Journals (Sweden)

    C.S. Alves

    2017-07-01

    Full Text Available We use Fisher Matrix analysis techniques to forecast the cosmological impact of astrophysical tests of the stability of the fine-structure constant to be carried out by the forthcoming ESPRESSO spectrograph at the VLT (due for commissioning in late 2017, as well by the planned high-resolution spectrograph (currently in Phase A for the European Extremely Large Telescope. Assuming a fiducial model without α variations, we show that ESPRESSO can improve current bounds on the Eötvös parameter—which quantifies Weak Equivalence Principle violations—by up to two orders of magnitude, leading to stronger bounds than those expected from the ongoing tests with the MICROSCOPE satellite, while constraints from the E-ELT should be competitive with those of the proposed STEP satellite. Should an α variation be detected, these measurements will further constrain cosmological parameters, being particularly sensitive to the dynamics of dark energy.

  1. Experimental test of theory for the stability of partially saturated vertical cut slopes

    Science.gov (United States)

    Morse, Michael M.; Lu, N.; Wayllace, Alexandra; Godt, Jonathan W.; Take, W.A.

    2014-01-01

    This paper extends Culmann's vertical-cut analysis to unsaturated soils. To test the extended theory, unsaturated sand was compacted to a uniform porosity and moisture content in a laboratory apparatus. A sliding door that extended the height of the free face of the slope was lowered until the vertical cut failed. Digital images of the slope cross section and upper surface were acquired concurrently. A recently developed particle image velocimetry (PIV) tool was used to quantify soil displacement. The PIV analysis showed strain localization at varying distances from the sliding door prior to failure. The areas of localized strain were coincident with the location of the slope crest after failure. Shear-strength and soil-water-characteristic parameters of the sand were independently tested for use in extended analyses of the vertical-cut stability and of the failure plane angle. Experimental failure heights were within 22.3% of the heights predicted using the extended theory.

  2. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  3. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    Science.gov (United States)

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.

  4. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  5. Solving ill-posed control problems by stabilized finite element methods: an alternative to Tikhonov regularization

    Science.gov (United States)

    Burman, Erik; Hansbo, Peter; Larson, Mats G.

    2018-03-01

    Tikhonov regularization is one of the most commonly used methods for the regularization of ill-posed problems. In the setting of finite element solutions of elliptic partial differential control problems, Tikhonov regularization amounts to adding suitably weighted least squares terms of the control variable, or derivatives thereof, to the Lagrangian determining the optimality system. In this note we show that the stabilization methods for discretely ill-posed problems developed in the setting of convection-dominated convection-diffusion problems, can be highly suitable for stabilizing optimal control problems, and that Tikhonov regularization will lead to less accurate discrete solutions. We consider some inverse problems for Poisson’s equation as an illustration and derive new error estimates both for the reconstruction of the solution from the measured data and reconstruction of the source term from the measured data. These estimates include both the effect of the discretization error and error in the measurements.

  6. Time-dependent algorithms for the simulation of viscoelastic flows with spectral element methods: applications and stability

    International Nuclear Information System (INIS)

    Fietier, Nicolas; Deville, Michel O.

    2003-01-01

    This paper presents the development of spectral element methods to simulate unsteady flows of viscoelastic fluids using a closed-form differential constitutive equation. The generation and decay Poiseuille planar flows are considered as benchmark problems to test the abilities of our computational method to deal with truly time-dependent flows. Satisfactory results converging toward steady-state regimes have been obtained for the flow through a four-to-one planar abrupt contraction with unsteady algorithms. Time-dependent simulations of viscoelastic flows are prone to numerical instabilities even for simple geometrical configurations. Possible methods to improve the numerical stability of the computational algorithms are discussed in view of the results carried out with numerical simulations for the flows through a straight channel and the four-to-one contraction

  7. How many trials are needed to achieve performance stability of the Timed Up & Go test in patients with hip fracture?

    DEFF Research Database (Denmark)

    Kristensen, Morten T; Ekdahl, Charlotte; Kehlet, Henrik

    2010-01-01

    To examine the number of trials needed to achieve performance stability of the Timed Up & Go (TUG) test using a standardized walking aid in patients with hip fracture who are allowed full weight bearing (FWB).......To examine the number of trials needed to achieve performance stability of the Timed Up & Go (TUG) test using a standardized walking aid in patients with hip fracture who are allowed full weight bearing (FWB)....

  8. The effects of different extraction methods on composition and storage stability of sturgeon oil.

    Science.gov (United States)

    Hao, Shuxian; Wei, Ya; Li, Laihao; Yang, Xianqing; Cen, Jianwei; Huang, Hui; Lin, Wanling; Yuan, Xiaomin

    2015-04-15

    The objective of this study was to assess the effect of different extraction methods on oil yield, colour attributes, oxidative stability, fatty acids composition and production of volatile compounds in sturgeon oil during storage. The supercritical fluid extraction (SFE) method with carbon dioxide resulted in higher oil yields, better colour attributes, and higher oxidative stability compared to other traditional extraction methods such as enzymatic extraction, amino, and wet reduction. After storage at 4 °C for 33 days, the aldehyde content in oil extracted by the enzymatic extraction and wet reduction methods was twice as high as that obtained by the other methods. There was a significant reduction in the content of total acids in oils extracted by the enzymatic extraction and wet reduction methods (poil extracted by the amino method. The oil extracted by SFE exhibited higher UFA and lower SFA. Significant diffidence among PUFA with C above 20 was observed in oil extracted with SFE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. A RECOMMENDED PASQUILL-GIFFORD STABILITY CLASSIFICATION METHOD FOR SAFETY BASIS ATMOSPHERIC DISPERSION MODELING AT SRS

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, C.

    2012-03-28

    Several of the most common methods for estimating Pasquill-Gifford (PG) stability (turbulence) class were evaluated for use in modeling the radiological consequences of SRS accidental releases using the MELCOR Accident Consequence Code System, Ver. 2 (MACCS2). Evaluation criteria included: (1) the ability of the method to represent diffusion characteristics above a predominantly forested landscape at SRS, (2) suitability of the method to provide data consistent with the formulation of the MACCS2 model, and (3) the availability of onsite meteorological data to support implementation of the method The evaluation resulted in a recommendation that PG stability classification for regulatory applications at SRS should be based on measurements of the standard deviation of the vertical component of wind direction fluctuations, {sigma}{sub e}, collected from the 61-m level of the SRS meteorological towers, and processed in full accordance with EPA-454/R-99-005 (EPA, 2000). This approach provides a direct measurement that is fundamental to diffusion and captures explicitly the turbulence generated by both mechanical and buoyant forces over the characteristic surface (forested) of SRS. Furthermore, due to the potentially significant enhancement of horizontal fluctuations in wind direction from the occurrence of meander at night, the use of {sigma}{sub e} will ensure a reasonably conservative estimate of PG stability class for use in dispersion models that base diffusion calculations on a single value of PG stability class. Furthermore, meteorological data bases used as input for MACCS2 calculations should contain hourly data for five consecutive annual periods from the most recent 10 years.

  10. Stabilization of the finite element method for the stationary Stokes problem for an incompressible fluid

    OpenAIRE

    Planas Badenas, Ramon

    2005-01-01

    The solution of the stationary Stokes problem through the finite element method using linear elements leads to instabilities in the obtained solution. There are two sources of difficulties to solve numerically this problem. The first one is related to the incompressibility condition and the second one relies in the analysis of the behavior of a bulid with high viscosity. This work is devoted to the analysis, and implementation in a Matlab code, of the Galerkin Least-Squares stabilization of t...

  11. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating LC-UV Method for Simultaneous Determination of Ketotifen and Cetirizine in Pharmaceutical Dosage Forms. ... 5 μm) using an isocratic mobile phase that consisted of acetonitrile and 10 mM disodium hydrogen phosphate buffer (pH 6.5) in a ratio of 45:55 % v/v at a flow ...

  12. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  13. Test methods for protective footwear against AP mine blast

    NARCIS (Netherlands)

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the

  14. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  15. A verification system survival probability assessment model test methods

    International Nuclear Information System (INIS)

    Jia Rui; Wu Qiang; Fu Jiwei; Cao Leituan; Zhang Junnan

    2014-01-01

    Subject to the limitations of funding and test conditions, the number of sub-samples of large complex system test less often. Under the single sample conditions, how to make an accurate evaluation of the performance, it is important for reinforcement of complex systems. It will be able to significantly improve the technical maturity of the assessment model, if that can experimental validation and evaluation model. In this paper, a verification system survival probability assessment model test method, the method by the test system sample test results, verify the correctness of the assessment model and a priori information. (authors)

  16. Perturbed Strong Stability Preserving Time-Stepping Methods For Hyperbolic PDEs

    KAUST Repository

    Hadjimichael, Yiannis

    2017-09-30

    A plethora of physical phenomena are modelled by hyperbolic partial differential equations, for which the exact solution is usually not known. Numerical methods are employed to approximate the solution to hyperbolic problems; however, in many cases it is difficult to satisfy certain physical properties while maintaining high order of accuracy. In this thesis, we develop high-order time-stepping methods that are capable of maintaining stability constraints of the solution, when coupled with suitable spatial discretizations. Such methods are called strong stability preserving (SSP) time integrators, and we mainly focus on perturbed methods that use both upwind- and downwind-biased spatial discretizations. Firstly, we introduce a new family of third-order implicit Runge–Kuttas methods with arbitrarily large SSP coefficient. We investigate the stability and accuracy of these methods and we show that they perform well on hyperbolic problems with large CFL numbers. Moreover, we extend the analysis of SSP linear multistep methods to semi-discretized problems for which different terms on the right-hand side of the initial value problem satisfy different forward Euler (or circle) conditions. Optimal perturbed and additive monotonicity-preserving linear multistep methods are studied in the context of such problems. Optimal perturbed methods attain augmented monotonicity-preserving step sizes when the different forward Euler conditions are taken into account. On the other hand, we show that optimal SSP additive methods achieve a monotonicity-preserving step-size restriction no better than that of the corresponding non-additive SSP linear multistep methods. Furthermore, we develop the first SSP linear multistep methods of order two and three with variable step size, and study their optimality. We describe an optimal step-size strategy and demonstrate the effectiveness of these methods on various one- and multi-dimensional problems. Finally, we establish necessary conditions

  17. Test Methods for Characterising Ore Comminution Behavior in Geometallurgy

    OpenAIRE

    Mwanga, Abdul

    2014-01-01

    Comminution test methods used within mineral processing have mainly been developed for selecting the most appropriate comminution technology for a given ore, designing a grinding circuit as well as sizing the equipment needed. Existing test methods usually require comparatively large sample amounts and are time-consuming to conduct. This makes comprehensive testing of ore comminution behavior – as required in the geometallurgical context – quite expensive. Currently the main interest in the c...

  18. Simulation of neoclassical tearing mode stabilization via minimum seeking method on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Park, M. H.; Kim, K.; Na, D. H.; Byun, C. S.; Na, Y. S. [Seoul National Univ., Seoul (Korea, Republic of); Kim, M. [FNC Technology Co. Ltd, Yongin (Korea, Republic of)

    2016-10-15

    Neoclassical tearing modes (NTMs) are well known resistive magnetohydrodynamic (MHD) instabilities. These instabilities are sustained by a helically perturbed bootstrap current. NTMs produce magnetic islands in tokamak plasmas that can degrade confinement and lead to plasma disruption. Because of this, the stabilization of NTMs is one of the key issues for tokamaks that achieve high fusion performance such as ITER. Compensating for the lack of bootstrap current by an Electron Cyclotron Current Drive (ECCD) has been proved experimentally as an effective method to stabilize NTMs. In order to stabilize NTMs, it is important to reduce misalignment. So that even ECCD can destabilize the NTMs when misalignment is large. Feedback control method that does not fully require delicate and accurate real-time measurements and calculations, such as equilibrium reconstruction and EC ray-tracing, has also been proposed. One of the feedback control methods is minimum seeking method. This control method minimizes the island width by tuning the misalignment, assuming that the magnetic island width is a function of the misalignment. As a robust and simple method of controlling NTM, minimum 'island width growth rate' seeking control is purposed and compared with performance of minimum ' island width' seeking control. At the integrated numerical system, simulations of the NTM suppression are performed with two types of minimum seeking controllers; one is a FDM based minimum seeking controller and the other is a sinusoidal perturbation based minimum seeking method. The full suppression is achieved both types of controller. The controllers adjust poloidal angle of EC beam and reduce misalignment to zero. The sinusoidal perturbation based minimum seeking control need to modify the adaptive gain.

  19. Phase stability analysis of liquid-liquid equilibrium with stochastic methods

    Directory of Open Access Journals (Sweden)

    G. Nagatani

    2008-09-01

    Full Text Available Minimization of Gibbs free energy using activity coefficient models and nonlinear equation solution techniques is commonly applied to phase stability problems. However, when conventional techniques, such as the Newton-Raphson method, are employed, serious convergence problems may arise. Due to the existence of multiple solutions, several problems can be found in modeling liquid-liquid equilibrium of multicomponent systems, which are highly dependent on the initial guess. In this work phase stability analysis of liquid-liquid equilibrium is investigated using the NRTL model. For this purpose, two distinct stochastic numerical algorithms are employed to minimize the tangent plane distance of Gibbs free energy: a subdivision algorithm that can find all roots of nonlinear equations for liquid-liquid stability analysis and the Simulated Annealing method. Results obtained in this work for the two stochastic algorithms are compared with those of the Interval Newton method from the literature. Several different binary and multicomponent systems from the literature were successfully investigated.

  20. Stability-Indicating RP-HPLC Method for Assay of Silver Lactate

    Directory of Open Access Journals (Sweden)

    V. Srinivasan

    2011-01-01

    Full Text Available A simple, economic and time-efficient stability-indicating, reverse-phase high-performance liquid chromatographic (RP-HPLC method has been developed for analysis of silver lactate in the presence of degradation products generated by decomposition. When silver lactate was subjected to acid hydrolysis, base hydrolysis, oxidative, photolytic, humidity and thermal stress, degradation was observed during base hydrolysis, oxidation, humidity and thermal stress. The drug was found to be stable to other stress conditions. Successful chromatographic condition of the drug from the degradation products formed under stress conditions was achieved on a phenomenex Gemini column with potassium dihydrogen phosphate buffer, pH adjusted to 2.2 with orthophosphoric acid, as mobile phase. The method was validated for linearity, precision, specificity and robustness and can be used for quality-control during manufacture and assessment of the stability of samples of silver lactate. To the best of our knowledge, a validated stability-indicating LC assay method for silver lactate based on lactic acid is reported for the first time.

  1. Multiple Linear Regression Modeling To Predict the Stability of Polymer-Drug Solid Dispersions: Comparison of the Effects of Polymers and Manufacturing Methods on Solid Dispersion Stability.

    Science.gov (United States)

    Fridgeirsdottir, Gudrun A; Harris, Robert J; Dryden, Ian L; Fischer, Peter M; Roberts, Clive J

    2018-03-29

    Solid dispersions can be a successful way to enhance the bioavailability of poorly soluble drugs. Here 60 solid dispersion formulations were produced using ten chemically diverse, neutral, poorly soluble drugs, three commonly used polymers, and two manufacturing techniques, spray-drying and melt extrusion. Each formulation underwent a six-month stability study at accelerated conditions, 40 °C and 75% relative humidity (RH). Significant differences in times to crystallization (onset of crystallization) were observed between both the different polymers and the two processing methods. Stability from zero days to over one year was observed. The extensive experimental data set obtained from this stability study was used to build multiple linear regression models to correlate physicochemical properties of the active pharmaceutical ingredients (API) with the stability data. The purpose of these models is to indicate which combination of processing method and polymer carrier is most likely to give a stable solid dispersion. Six quantitative mathematical multiple linear regression-based models were produced based on selection of the most influential independent physical and chemical parameters from a set of 33 possible factors, one model for each combination of polymer and processing method, with good predictability of stability. Three general rules are proposed from these models for the formulation development of suitably stable solid dispersions. Namely, increased stability is correlated with increased glass transition temperature ( T g ) of solid dispersions, as well as decreased number of H-bond donors and increased molecular flexibility (such as rotatable bonds and ring count) of the drug molecule.

  2. A new method for evaluating structural stability of bulk metallic glasses

    International Nuclear Information System (INIS)

    Zhao, Lei; Jia, Haoling; Xie, Shenghui; Zeng, Xierong; Zhang, Tao; Ma, Chaoli

    2010-01-01

    This paper proposed a new method for evaluating the structural stability of bulk metallic glasses (BMGs) based on dilatometric measurements. During heating in the dilatometric experiments, the BMGs expanded continuously with increasing temperature. When the temperature reached the glass transition temperature (T g ), viscous shrinkage occurred due to the viscosity of material becoming lower. Since the inhomogeneous nature of the metallic glasses at atomic level, the processes of rigid expansion and the viscous shrinkage co-exist in a certain temperature region. The expansion stopped completely at a temperature (named T p here) beyond T g . The values of the temperature region, ΔT gp = T p - T g , and the corresponding time interval (Δt gp ) and the activation energy (E p ) corresponding to the expansion processes, are the reflection of the structural stability of BMGs. Investigating the co-existing processes kinetically and thermodynamically, we can make an insight into the structural stability of metallic glasses. Based on this idea, the thermal expansion behaviors of Mg-, Pd-, Zr-, Ti- and Fe-based BMG were studied, and their structural stability was evaluated by the parameters of ΔT gp , Δt gp and E p .

  3. Towards a Scalable Fully-Implicit Fully-coupled Resistive MHD Formulation with Stabilized FE Methods

    Energy Technology Data Exchange (ETDEWEB)

    Shadid, J N; Pawlowski, R P; Banks, J W; Chacon, L; Lin, P T; Tuminaro, R S

    2009-06-03

    This paper presents an initial study that is intended to explore the development of a scalable fully-implicit stabilized unstructured finite element (FE) capability for low-Mach-number resistive MHD. The discussion considers the development of the stabilized FE formulation and the underlying fully-coupled preconditioned Newton-Krylov nonlinear iterative solver. To enable robust, scalable and efficient solution of the large-scale sparse linear systems generated by the Newton linearization, fully-coupled algebraic multilevel preconditioners are employed. Verification results demonstrate the expected order-of-acuracy for the stabilized FE discretization of a 2D vector potential form for the steady and transient solution of the resistive MHD system. In addition, this study puts forth a set of challenging prototype problems that include the solution of an MHD Faraday conduction pump, a hydromagnetic Rayleigh-Bernard linear stability calculation, and a magnetic island coalescence problem. Initial results that explore the scaling of the solution methods are presented on up to 4096 processors for problems with up to 64M unknowns on a CrayXT3/4. Additionally, a large-scale proof-of-capability calculation for 1 billion unknowns for the MHD Faraday pump problem on 24,000 cores is presented.

  4. Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible

    Science.gov (United States)

    Shokri, Mehran; Daraeighadikolaei, Arash

    2013-01-01

    Background. There is no doubt that the success of the dental implants depends on the stability. The aim of this work was to measure the stability of dental implants prior to loading the implants, using a resonance frequency analysis (RFA) by Osstell mentor device. Methods. Ten healthy and nonsmoker patients over 40 years of age with at least six months of complete or partial edentulous mouth received screw-type dental implants by a 1-stage procedure. RFA measurements were obtained at surgery and 1, 2, 3, 4, 5, 7, and 11 weeks after the implant surgery. Results. Among fifteen implants, the lowest mean stability measurement was for the 4th week after surgery in all bone types. At placement, the mean ISQ obtained with the magnetic device was 77.2 with 95% confidence interval (CI) = 2.49, and then it decreased until the 4th week to 72.13 (95% CI = 2.88), and at the last measurement, the mean implant stability significantly (P value implant placement. These suggestions need to be further assessed through future studies. PMID:23737790

  5. A new method for evaluating structural stability of bulk metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Lei; Jia, Haoling [Key Laboratory of Aerospace Materials and Performance, Ministry of Education, School of Materials Science and Engineering, Beihang University, Beijing 100191 (China); Xie, Shenghui; Zeng, Xierong [College of Materials Science and Engineering, Shenzhen University and Shenzhen Key Laboratory of Special Functional Materials, ShenZhen 518060 (China); Zhang, Tao [Key Laboratory of Aerospace Materials and Performance, Ministry of Education, School of Materials Science and Engineering, Beihang University, Beijing 100191 (China); Ma, Chaoli, E-mail: machaoli@buaa.edu.c [Key Laboratory of Aerospace Materials and Performance, Ministry of Education, School of Materials Science and Engineering, Beihang University, Beijing 100191 (China)

    2010-08-15

    This paper proposed a new method for evaluating the structural stability of bulk metallic glasses (BMGs) based on dilatometric measurements. During heating in the dilatometric experiments, the BMGs expanded continuously with increasing temperature. When the temperature reached the glass transition temperature (T{sub g}), viscous shrinkage occurred due to the viscosity of material becoming lower. Since the inhomogeneous nature of the metallic glasses at atomic level, the processes of rigid expansion and the viscous shrinkage co-exist in a certain temperature region. The expansion stopped completely at a temperature (named T{sub p} here) beyond T{sub g}. The values of the temperature region, {Delta}T{sub gp} = T{sub p} - T{sub g}, and the corresponding time interval ({Delta}t{sub gp}) and the activation energy (E{sub p}) corresponding to the expansion processes, are the reflection of the structural stability of BMGs. Investigating the co-existing processes kinetically and thermodynamically, we can make an insight into the structural stability of metallic glasses. Based on this idea, the thermal expansion behaviors of Mg-, Pd-, Zr-, Ti- and Fe-based BMG were studied, and their structural stability was evaluated by the parameters of {Delta}T{sub gp}, {Delta}t{sub gp} and E{sub p}.

  6. Development and validation of an HPLC method for stability evaluation of nystatin

    Directory of Open Access Journals (Sweden)

    Ana Paola Prata Cione

    2010-06-01

    Full Text Available A liquid chromatography method for evaluating the stability of Nystatin (Nys in an ointment was developed and validated, since the traditional pharmacopeial microbiological methods are unable to indicate stability. The stress experiments showed that Nys was found to significantly degrade in alkaline and acidic conditions and also under oxidative stress. Lower levels of degradation were detected under heat and with the sample exposed to Xenon light. Resolutions higher than 2 for Nys and degradation products (DP chromatographic peaks were achieved by using an Inerstil ODS-3 column, isocratic elution with methanol:water and UV detection at 305 nm. The system was found to be linear over a range of 102 to 310 IU mL-1 and proved precise, since the RSD(% was 0.24% for the six replicates tested. The method also exhibited good levels of recovery (from 98.24% to 100.74%. Therefore, the validation fulfilled pharmacopeial requirements and the procedure was found to be reliable, precise, accurate and selective for determination of Nys and its degradation products.Um método indicador de estabilidade por cromatografia líquida foi desenvolvido e validado para a análise de Nistatina (Nys em uma pomada, uma vez que os métodos microbiológicos tradicionais não têm a habilidade de serem indicadores de estabilidade. A nistatina degradou significativamente em condições alcalinas e ácidas e também em meio oxidante. Quando a amostra foi exposta a luz de xenônio, foram observados menores níveis de degradação. A resolução entre os picos cromatográficos de Nys e seus produtos de degradação (PD foi maior que 2, utilizando-se uma coluna Inerstil ODS-3, eluição isocrática com metanol: água e detecção no UV em 305 nm. O sistema foi linear entre a faixa de 102 a 310 UI mL-1 e preciso uma vez que o DPR(% foi de 0,24% entre as seis replicatas testadas. Além disso, o método exibiu bons níveis de recuperação (de 98,24% a 100,74%. Consequentemente

  7. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    as requirements for experimental facilities are very demanding and furthermore the time for performing the experimental test campaign and the cost are not well suitable for most research projects. This report deals with the advantages, disadvantages and open questions of using down-scaled testing on wind turbine......Full scale fatigue test is an important part of the development and design of wind turbine blades. Testing is also needed for the approval of the blades in order for them to be used on large wind turbines. Fatigue test of wind turbine blades was started in the beginning of the 1980s and has been...... further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  8. Stability analysis of Eulerian-Lagrangian methods for the one-dimensional shallow-water equations

    Science.gov (United States)

    Casulli, V.; Cheng, R.T.

    1990-01-01

    In this paper stability and error analyses are discussed for some finite difference methods when applied to the one-dimensional shallow-water equations. Two finite difference formulations, which are based on a combined Eulerian-Lagrangian approach, are discussed. In the first part of this paper the results of numerical analyses for an explicit Eulerian-Lagrangian method (ELM) have shown that the method is unconditionally stable. This method, which is a generalized fixed grid method of characteristics, covers the Courant-Isaacson-Rees method as a special case. Some artificial viscosity is introduced by this scheme. However, because the method is unconditionally stable, the artificial viscosity can be brought under control either by reducing the spatial increment or by increasing the size of time step. The second part of the paper discusses a class of semi-implicit finite difference methods for the one-dimensional shallow-water equations. This method, when the Eulerian-Lagrangian approach is used for the convective terms, is also unconditionally stable and highly accurate for small space increments or large time steps. The semi-implicit methods seem to be more computationally efficient than the explicit ELM; at each time step a single tridiagonal system of linear equations is solved. The combined explicit and implicit ELM is best used in formulating a solution strategy for solving a network of interconnected channels. The explicit ELM is used at channel junctions for each time step. The semi-implicit method is then applied to the interior points in each channel segment. Following this solution strategy, the channel network problem can be reduced to a set of independent one-dimensional open-channel flow problems. Numerical results support properties given by the stability and error analyses. ?? 1990.

  9. Test methods for protective footwear against AP mine blast

    OpenAIRE

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the effects of anti-personnel blast mines. Experimental testing requires the definition of a threat and a means of assessing the expected trauma to the human leg. The latter is accomplished with various phy...

  10. Colour-Value Based Method for Polydopamine Coating-Stability Characterization on Polyethersulfone Membranes

    Directory of Open Access Journals (Sweden)

    Thomas Bucher

    2017-12-01

    Full Text Available Porous polyethersulfone membranes as used in oenology were investigated in order to evaluate temperature-dependent permeances in a temperature range from 10 to 35 °C. A temperature correction factor was determined for this type of membrane to get accurate and comparable results for further developments. Moreover, the membranes were modified with a bio-inspired polydopamine coating in order to reduce fouling. The performance of the membranes could be increased with respect to permeance and flux recovery under cross-flow conditions. In order to test the applicability and stability of the coating layer, they were treated with basic and acidic cleaning agents as used in industry for fouled membranes. The chemical stability of the coating layer was studied under basic and acidic conditions, by systematic observation of the colour change of the coated membranes over treatment time.

  11. Colour-Value Based Method for Polydopamine Coating-Stability Characterization on Polyethersulfone Membranes.

    Science.gov (United States)

    Bucher, Thomas; Clodt, Juliana I; Grabowski, Andrej; Hein, Martin; Filiz, Volkan

    2017-12-16

    Porous polyethersulfone membranes as used in oenology were investigated in order to evaluate temperature-dependent permeances in a temperature range from 10 to 35 °C. A temperature correction factor was determined for this type of membrane to get accurate and comparable results for further developments. Moreover, the membranes were modified with a bio-inspired polydopamine coating in order to reduce fouling. The performance of the membranes could be increased with respect to permeance and flux recovery under cross-flow conditions. In order to test the applicability and stability of the coating layer, they were treated with basic and acidic cleaning agents as used in industry for fouled membranes. The chemical stability of the coating layer was studied under basic and acidic conditions, by systematic observation of the colour change of the coated membranes over treatment time.

  12. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  13. Electrocatalytic Activity and Stability of M-Fe Catalysts Synthesized by Polymer Complex Method for PEFC Cathode

    KAUST Repository

    Ou, Yiwei

    2011-11-01

    The polymerized complex (PC) method was used to synthesize highly dispersed iron-based catalysts for the oxygen reduction reaction (ORR). The catalysts were prepared with an addition of 1,10-phenanthroline (Phen) and transition metals (M), such as Ta, Ti, and W, in an attempt to enhance the ORR activity and durability of the catalysts. The composition and properties of the catalysts were characterized by thermogravimetric analysis, X-ray diffraction, and X-ray photoelectron spectroscopy. The catalyst components, after extensive dissolution in a strong acid solution, were characterized by inductively coupled plasma mass spectroscopy and ultraviolet-visible spectroscopy. It was found that the Ti-Fe catalyst showed improved ORR performance, and the Ta-Fe catalyst showed enhanced stability towards ORR in acidic solution. The catalytic activity and stability for ORR was observed by adding Ti or Ta into the catalyst formulation, suggesting that the interaction between added hetero-ions (Ti and Ta) and ionic Fe active sites was beneficial for the ORR. A single-cell test with the synthesized catalyst in the cathode initially generated a high power density, but the low stability remains an issue to be solved.

  14. 40 CFR 264.1063 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... CFR part 60. (2) The detection instrument shall meet the performance criteria of Reference Method 21... determined as set forth in Reference Method 21. (3) The instrument probe shall be traversed around all... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Test methods and procedures. 264.1063...

  15. Light scattering methods to test inorganic PCMs for application in buildings

    Science.gov (United States)

    De Paola, M. G.; Calabrò, V.; De Simone, M.

    2017-10-01

    Thermal performance and stability over time are key parameters for the characterization and application of PCMs in the building sector. Generally, inorganic PCMs are dispersions of hydrated salts and additives in water that counteract phase segregation phenomena and subcooling. Traditional methods or in “house” methods can be used for evaluating thermal properties, while stability can be estimated over time by using optical techniques. By considering this double approach, in this work thermal and structural analyses of Glauber salt based composite PCMs are conducted by means of non-conventional equipment: T-history method (thermal analysis) and Turbiscan (stability analysis). Three samples with the same composition (Glauber salt with additives) were prepared by using different sonication times and their thermal performances were compared by testing both the thermal cycling and the thermal properties. The stability of the mixtures was verified by the identification of destabilization phenomena, the evaluation of the migration velocities of particles and the estimation of variation of particle size.

  16. Multi-Mission Earth Vehicle Subsonic Dynamic Stability Testing and Analyses

    Science.gov (United States)

    Glaab, Louis J.; Fremaux, C. Michael

    2013-01-01

    Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes, retro-rockets, and reaction control systems and rely on the natural aerodynamic stability of the vehicle throughout the Entry, Descent, and Landing (EDL) phase of flight. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs for an array of missions and develop and visualize the trade space. Testing in NASA Langley?s Vertical Spin Tunnel (VST) was conducted to significantly improve M-SAPE?s subsonic aerodynamic models. Vehicle size and shape can be driven by entry flight path angle and speed, thermal protection system performance, terminal velocity limitations, payload mass and density, among other design parameters. The objectives of the VST testing were to define usable subsonic center of gravity limits, and aerodynamic parameters for 6-degree-of-freedom (6-DOF) simulations, for a range of MMEEV designs. The range of MMEEVs tested was from 1.8m down to 1.2m diameter. A backshell extender provided the ability to test a design with a much larger payload for the 1.2m MMEEV.

  17. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    on these efficiencies, an efficiency equation is determined by regression analysis. In the test method, there are no requirements on the ambient air temperature and the sky temperature. The paper will present an evaluation of the test method for a 12.5 m² flat plate solar collector panel from Arcon Solvarme A....../S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...

  18. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  19. The Iosipescu shear test method as used for testing polymers and composite materials

    Science.gov (United States)

    Adams, Donald F.

    1990-01-01

    This paper describes a shear test method for polymers and composite materials, based on the Iosipescu (1967) shear test which was originally developed for use with homogeneous isotropic metals. Special attention is given to the loading fixture for the test, the standard specimen design and shear stress measurements. The range of the test applications is indicated. The method is in the final stages of being accepted as an ASTM standard.

  20. Method for rapid optimization of recombinant GPCR protein expression and stability using virus-like particles.

    Science.gov (United States)

    Ho, Thao T; Nguyen, Jasmine T; Liu, Juping; Stanczak, Pawel; Thompson, Aaron A; Yan, Yingzhuo G; Chen, Jasmine; Allerston, Charles K; Dillard, Charles L; Xu, Hao; Shoger, Nicholas J; Cameron, Jill S; Massari, Mark E; Aertgeerts, Kathleen

    2017-05-01

    Recent innovative approaches to stabilize and crystallize GPCRs have resulted in an unprecedented breakthrough in GPCR crystal structures as well as application of the purified receptor protein in biophysical and biochemical ligand binding assays. However, the protein optimization process to enable these technologies is lengthy and requires iterative overexpression, solubilization, purification and functional analysis of tens to hundreds of protein variants. Here, we report a new and versatile method to screen in parallel hundreds of GPCR variants in HEK293 produced virus-like particles (VLPs) for protein yield, stability, functionality and ligand binding. This approach reduces the time and resources during GPCR construct optimization by eliminating lengthy protein solubilization and purification steps and by its adaptability to many binding assay formats (label or label-free detection). We exemplified the robustness of our VLP method by screening 210 GALR3-VLP variants in a radiometric agonist-based binding assay and a subset of 88 variants in a label-free antagonist-based assay. The resulting GALR3 agonist or antagonist stabilizing variants were then further used for recombinant protein expression in transfected insect cells. The final purified protein variants were successfully immobilized on a biosensor chip and used in a surface plasmon resonance binding assay. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Laboratory research on tailings stabilization methods and their effectiveness in radiation containment

    International Nuclear Information System (INIS)

    Macbeth, P.J.; Jensen, C.M.; Rogers, V.C.; Overmyer, R.F.

    1978-04-01

    This report describes a study of various methods, techniques, and materials for stabilizing uranium mill tailings to reduce radon exhalation. Radon emanation from tailings particles, radon exhalation from tailings, and methods that could be used to reduce radon exhalation from tailings piles are discussed. Surface radon flux and soil gas concentrations were measured in experiment chambers or columns consisting of uranium tailings and various types and thicknesses of cover materials. The applicability of diffusion theory was examined and effective diffusion coefficients were determined for clay, soil, and sand. The variation of radon flux with atmospheric effects and moisture also was investigated. The effectiveness of several types of chemical stabilizers for both volumetric and surface application in reducing radon exhalation is reported. Some volumetric stabilizers reduced radon flux by 90 percent or more. Radon flux was determined through the use of charcoal gas mask canisters, and flux accumulation chambers sampled by Lucas cells. Both of these techniques are described. Soil gas concentration was sampled with Lucas cells and counted with a sodium iodide scintillation spectrometer system. Emanating power of uranium tailings was measured for several particle sizes and found to be relatively constant at about 20 percent. Two types of grasses were found that would grow in tailings if sufficient water and fertilizer were provided. The effect of vegetation on radon exhalation was not determined

  2. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.

  3. A validated stability-indicating UPLC method for desloratadine and its impurities in pharmaceutical dosage forms.

    Science.gov (United States)

    Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K

    2010-02-05

    A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.

  4. Modified Limiting Equilibrium Method for Stability Analysis of Stratified Rock Slopes

    Directory of Open Access Journals (Sweden)

    Rui Yong

    2016-01-01

    Full Text Available The stratified rock of Jurassic strata is widely distributed in Three Gorges Reservoir Region. The limit equilibrium method is generally utilized in the stability analysis of rock slope with single failure plane. However, the stratified rock slope cannot be accurately estimated by this method because of different bedding planes and their variable shear strength parameters. Based on the idealized model of rock slope with bedding planes, a modified limiting equilibrium method is presented to determine the potential sliding surface and the factor of safety for the stratified rock slope. In this method, the S-curve model is established to define the spatial variations of the shear strength parameters c and  φ of bedding plane and the tensile strength of rock mass. This method was applied in the stability evaluation of typical stratified rock slope in Three Gorges Reservoir Region, China. The result shows that the factor of safety of the case study is 0.973, the critical sliding surface for the potential slip surface appears at bedding plane C, and the tension-controlled failure occurs at 10.5 m to the slope face.

  5. The influence of technical testing methods on perceptions of constructions

    International Nuclear Information System (INIS)

    Oestberg, Gustaf

    2002-01-01

    In principle, methods of testing the reliability and safety of constructions are designed with the aim of representing critical conditions for their use. Because of variations within technical systems, including the one for which a certain test was once developed, the validity of the method also varies. The adoption of a standardized test for different applications had to be based on the assumption that the test deals adequately with a real situation. As a consequence of this acceptance of a trustworthy relationship between test and reality, an imprint of the former on the latter occurs. This effect may even cause the perception of a reality to be defined by the corresponding test. Examples of such an influence may be found in the field of materials testing. Related phenomena can be dealt with by reference to current concepts of cognitive science and psychology of the perception of images

  6. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  7. A new method of improving the acceleration voltage stability of Van de Graaff accelerators

    Science.gov (United States)

    Bürger, W.; Lange, H.; Petr, V.

    2008-02-01

    The relative energy stability of Van de Graaff type ion accelerators is typically limited to some 10-4. An inexpensive possibility to improve this situation was developed at the Forschungszentrum Dresden-Rossendorf. The method refers to the relatively stable periodic pattern of the acceleration voltage fluctuation in such accelerators. Future values of that fluctuation can be predicted with a high degree of certainty and can taken into account in the belt generator control in spite of the belt convolution caused fundamental reaction delay. The microcontroller based implementation of a "predictive fluctuation compensation" improves the relative acceleration voltage short time stability by a factor of 3-6 to well below 10-4.

  8. Method for determining asphaltene stability of a hydrocarbon-containing material

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, John F; Rovani, Jr., Joseph F

    2013-02-05

    A method for determining asphaltene stability in a hydrocarbon-containing material having solvated asphaltenes therein is disclosed. In at least one embodiment, it involves the steps of: (a) precipitating an amount of the asphaltenes from a liquid sample of the hydrocarbon-containing material with an alkane mobile phase solvent in a column; (b) dissolving a first amount and a second amount of the precipitated asphaltenes by changing the alkane mobile phase solvent to a final mobile phase solvent having a solubility parameter that is higher than the alkane mobile phase solvent; (c) monitoring the concentration of eluted fractions from the column; (d) creating a solubility profile of the dissolved asphaltenes in the hydrocarbon-containing material; and (e) determining one or more asphaltene stability parameters of the hydrocarbon-containing material.

  9. New stability criterion of neural networks with leakage delays and impulses: a piecewise delay method.

    Science.gov (United States)

    Kumar, R Suresh; Sugumaran, G; Raja, R; Zhu, Quanxin; Raja, U Karthik

    2016-02-01

    This paper analyzes the global asymptotic stability of a class of neural networks with time delay in the leakage term and time-varying delays under impulsive perturbations. Here the time-varying delays are assumed to be piecewise. In this method, the interval of the variation is divided into two subintervals by its central point. By developing a new Lyapunov-Krasovskii functional and checking its variation in between the two subintervals, respectively, and then we present some sufficient conditions to guarantee the global asymptotic stability of the equilibrium point for the considered neural network. The proposed results which do not require the boundedness, differentiability and monotonicity of the activation functions, can be easily verified via the linear matrix inequality (LMI) control toolbox in MATLAB. Finally, a numerical example and its simulation are given to show the conditions obtained are new and less conservative than some existing ones in the literature.

  10. Method and apparatus for stabilizing signals in radioactive well logging tools

    International Nuclear Information System (INIS)

    Kampfer, J.G.; Ingram, L.A.

    1977-01-01

    A method and apparatus are presented for stabilizing signals in radioactive well logging tools. In the tool a main scintillating crystal and photomultiplier tube for detecting radiation induced in the borehole by a source of radiation are provided and a reference crystal, including a source of mono-energetic radiation, for producing continuous reference signals of a predetermined energy level. The signals are monitored and the spectrum is stabilized to correct for drift of the data signals introduced by the photomultiplier tube and the data transmission system. The preferred mono-energetic reference signals are selected to appear in the energy spectrum at a level which minimizes error. An electronic circuit at the surface provides a correction signal for adjusting the gain of a data signal amplifier responsive to changes in the reference signal, thereby correcting for drift in the data signal

  11. Eigenvalue-based harmonic stability analysis method in inverter-fed power systems

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2015-01-01

    This paper presents an eigenvalue-based harmonic stability analysis method for inverter-fed power systems. A full-order small-signal model for a droop-controlled Distributed Generation (DG) inverter is built first, including the time delay of digital control system, inner current and voltage...... control loops, and outer droop-based power control loop. Based on the inverter model, an overall small-signal model of a two-inverter-fed system is then established, and the eigenvalue-based stability analysis is subsequently performed to assess the influence of controller parameters on the harmonic...... resonance and instability in the power system. Eigenvalues associated with time delay of inverter and inner controller parameters is obtained, which shows the time delay has an important effect on harmonic instability of inverter-fed power systems. Simulation results are given for validating the proposed...

  12. Stability of the offset V-osteotomy. Test jig development and saw bone model assessment.

    Science.gov (United States)

    Gonda, Elizabeth; Bauer, Gary R; Hillstrom, Howard J; Song, Jinsup; Cho, Helen H; Lundberg, Lori A

    2002-02-01

    In the offset V-bunionectomy used for hallux valgus repair, both the Kalish and the Vogler variations have a long dorsal arm, but the apex is more distal in the Kalish procedure. This study investigated the effect that pin orientation and location of the osteotomy apex have on weightbearing stability. The authors studied saw bone models that were loaded to failure in an Instron 4201 materials testing machine and, in addition, designed, fabricated, and used a unique jig assembly to help minimize data variability. Statistically significant differences were found between the surgical techniques and pin orientations: the Kalish osteotomy was stronger than the Vogler procedure, and in both osteotomies, the plantarly directed Kirschner wire orientation was stronger than the dorsally directed orientation.

  13. Testing baseline stability of some neutron monitors in Europe, Africa, and Asia

    Science.gov (United States)

    Ahluwalia, H. S.; Ygbuhay, R. C.

    2013-06-01

    For six decades, the global network of neutron monitors (NMs) has provided a continuous stream of very valuable data to the heliophysics community, leading to many insights into the myriad modes of charged particle transport in the tangled magnetic fields that permeate the 3D heliosphere. Earlier, Ahluwalia and Ygbuhay (2012) reported on the drifts in some high latitude NM counting rates in the American zone. We continue our enquiry by testing the stability of the counting rate baselines of some NMs operating in Europe, Africa, and Asia. The data from these detectors have been extremely valuable for the short-term time variation studies, but caution is advised in using the data for long-term studies from NMs with baselines that are drifting for cause(s) unknown.

  14. Use of Small-Angle Neutron Scattering in Testing the Stability of Ferrofluids

    CERN Document Server

    Balasoiu, M; Avdeev, M V; Aksenov, V L; Khokhryakov, A A; Bica, L D; Hasegan, D; Török, G; Rosta, L

    2004-01-01

    Stability of ferrofluids - colloidal solutions of magnetic particles covered with surfactants - is the main characteristic that determines the possibility to exploit ferrofluids in different industrial and biomedical applications. Small-angle neutron scattering (SANS) can be effectively used to reveal the aggregation and its change with time in ferrofluids under the action of magnetic field. Despite the fact that in most cases the detailed description of scattering is complicated, one can judge whether a ferrofluid is stable or not by simple analysis of changes in the mean scattering intensity. The advantages of SANS are that industrial samples can be tested without any additional modifications, as well as the real-time experiments with any magnetic load can be easily performed. Examples for a number of ferrofluids are given.

  15. Alternative methods for ocular toxicology testing: validation, applications and troubleshooting.

    Science.gov (United States)

    Dholakiya, Sanjay L; Barile, Frank A

    2013-06-01

    Humanitarian concern, scientific progress and legislative action have lead to the development, validation and regulatory acceptance of alternative in vitro ocular models. However, to date not a single in vitro alternative ocular toxicity test has been validated as a full replacement for the in vivo Draize rabbit eye test for all classes of chemicals across whole irritancy ranges. Since the 1990s, ocular alternative methods have been validated but few have been accepted for regulatory purposes. These assays include: organotypic models, such as the bovine corneal opacity and permeability (BCOP) assay, the isolated chicken eye (ICE) test method and cell function-based in vitro assays, such as the cytosensor microphysiometer (CM) and the fluorescein leakage (FL) test methods. Some refinements to in vivo testing methods have been accepted by regulatory agencies, including humane endpoints to avoid or minimize pain and distress. The authors provide a review of the background, protocol overview, applications and their validation status of the tier-testing approach. Furthermore, the authors provide expert analysis and provide their perspective on this approach and potential future developments. In the search for a battery of methods that replaces the in vivo Draize test, it is necessary to prioritize techniques, define related mechanisms and justify statistical approaches. Overall, only when the reliability and relevance of a method is unequivocally supported will any technique be ready for regulatory acceptance.

  16. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  17. A rapid stability indicating LC-method for determination of praziquantel in presence of its pharmacopoeial impurities

    Directory of Open Access Journals (Sweden)

    Hisham Hashem

    2017-02-01

    Full Text Available This study reports for the first time about a stability indicating RP-HPLC method for quantitative determination of Praziquantel (PZQ in bulk powder and dosage form and in presence of its pharmacopoeial impurities. The chromatographic separation was carried out on (Caltrex AI® calixarene column, a relatively new packing material. Chromatography was done using an isocratic binary mobile phase consisting of ACN and 25 mM ammonium acetate (NH4Ac in the ratio of 40:60 at flow rate of 1 mL min−1, 30 °C and 210 nm wavelength for detection. The elution time of PZQ was found to be 6.15 ± 0.03 min. The method was validated for system suitability, linearity, precision, limits of detection and quantitation, specificity, stability and robustness. The robustness study was done for small changes in temperature, flow rate, wavelength of detection and % of ACN in mobile phase. Stability tests were done through exposure of the analyte solution to five different stress conditions: Reflux with 1 N HCl, reflux with 1 N NaOH, reflux with 30% H2O2, thermal degradation of powder and exposure to UV radiation. Limits of detection and quantification were found to be 0.56 and 1.70 μg mL−1, respectively. The recovery value of this method was 100.30% ± 1.10 and the reproducibility was within 1.31.

  18. Stability, accuracy, and efficiency of some underintegrated methods in finite element computations

    Science.gov (United States)

    Jacquotte, O.-P.

    1985-01-01

    In an attempt to increase computational efficiency in the numerical solution of highly nonlinear problems in solid and fluid mechanics, underintegrated finite element methods have been employed by many analysts. Underintegration refers to the use of a rule of an order lower than that required to integrate polynomial integrands exactly. The main drawback of this technique is related to the production of rank-deficient stiffness matrices, or equivalently an expanded kernel of the governing linear momentum operators. Such a development can introduce numerical instabilities. In order to overcome this difficulty, artificial stiffness or viscosity methods, or other stabilization methods have been proposed. One approach involves the elimination of spurious modes in a postprocessing operation. The present study is concerned with this a posteriori elimination method, taking into account the results which can be expected from it, and some of its possible extensions.

  19. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  20. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  1. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00216540; The ATLAS collaboration; Leone, Sandra; Scuri, Fabrizio

    2017-01-01

    High performance of the ATLAS Tile Calorimeter response is achieved with a multi- stage calibration. One step of the calibration is based on measurements of the response to laser pulse excitation of the PMTs used to read out the calorimeter cells. A facility to study the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response as a function of the integrated anode charge and to compare test bench results with the observed response drifts of the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility is described and the first results obtained by testing about 30 PMTs Hamamatsu model R7877 (a special evolution f...

  2. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    CERN Document Server

    Kazanin, Vassili; The ATLAS collaboration; Scuri, Fabrizio

    2017-01-01

    High performance of the ATLAS Tile Calorimeter response is achieved with a multi-stage calibration. One step of the calibration is based on measurements of the response to laser pulse excitation of the PMTs used to read out the calorimeter cells. A facility to study the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response as a function of the integrated anode charge and to compare test bench results with the observed response drifts of the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility is described and the first results obtained by testing about 30 PMTs Hamamatsu model R7877 (a special evolution fo...

  3. Influence of the Roof Movement Control Method on the Stability of Remnant

    Science.gov (United States)

    Adach-Pawelus, Karolina

    2017-12-01

    In the underground mines, there are geological and mining situations that necessitate leaving behind remnants in the mining field. Remnants, in the form of small, irregular parcels, are usually separated in the case of: significant problems with maintaining roof stability, high rockburst hazard, the occurrence of complex geological conditions and for random reasons (ore remnants), as well as for economic reasons (undisturbed rock remnants). Remnants left in the mining field become sites of high stress values concentration and may affect the rock in their vicinity. The values of stress inside the remnant and its vicinity, as well as the stability of the remnant, largely depend on the roof movement control method used in the mining field. The article presents the results of the numerical analysis of the influence of roof movement control method on remnant stability and the geomechanical situation in the mining field. The numerical analysis was conducted for the geological and mining conditions characteristic of Polish underground copper mines owned by KGHM Polska Miedz S.A. Numerical simulations were performed in a plane strain state by means of Phase 2 v. 8.0 software, based on the finite element method. The behaviour of remnant and rock mass in its vicinity was simulated in the subsequent steps of the room and pillar mining system for three types of roof movement control method: roof deflection, dry backfill and hydraulic backfill. The parameters of the rock mass accepted for numerical modelling were calculated by means of RocLab software on the basis of the Hoek-Brown classification. The Mohr-Coulomb strength criterion was applied.

  4. Stability Indicating Liquid Chromatographic Method for Simultaneous determination of Aspirin and Omeprazole.

    Science.gov (United States)

    Patel, Vandana B; Patel, Aishwarya D; Shah, Dimal A

    2017-10-23

    Aspirin combination is prescribed for the its thrombolytic activity where gastric ulceration is the major side effects of aspirin which can be prevented by combining it with proton pump inhibitor omeprazole. Present study describes development of analytical method for the estimation of aspirin and omeprazole in combination. Objective of the present study was to develop and validate chromatographic method for simultaneous analysis of aspirin and omeprazole. Isocratic, reversed phase stability indicating liquid chromatographic method was developed for the simultaneous determination of Aspirin and Omeprazole in combination. The separation was achieved on a Thermo Scientific Hypersil ODS (250 x 4.6 mm, 5 µm) column, kept at ambient temperature, using acetonitrile: methanol: 0.05 M phosphate buffer (40:5:55; pH 4 adjusted with 0.1% tri ethyl amine) as a mobile phase at a flow rate of 1 mL/min and UV detection was performed at 225 nm. The retention time was found to be 3.9 min for aspirin and 5.3 min for omeprazole. The method was oberved to be linear in the range of 2 - 80 μg/mL for aspirin and 1 - 40 μg/mL for omeprazole, respectively. The proposed method was validated as per ICH guidelines Q2 (R1). The developed RP- HPLC method was successfully applied for the simultaneous estimation of aspirin and omeprazole in the presence of degradation products of both the drugs. The present study describes liquid chromatographic method for the estimation of aspirin and omeprzole in combination. The method can be used for the analysis of stability samples and routine quality control samples. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Natural colorants: Pigment stability and extraction yield enhancement via utilization of appropriate pretreatment and extraction methods.

    Science.gov (United States)

    Ngamwonglumlert, Luxsika; Devahastin, Sakamon; Chiewchan, Naphaporn

    2017-10-13

    Natural colorants from plant-based materials have gained increasing popularity due to health consciousness of consumers. Among the many steps involved in the production of natural colorants, pigment extraction is one of the most important. Soxhlet extraction, maceration, and hydrodistillation are conventional methods that have been widely used in industry and laboratory for such a purpose. Recently, various non-conventional methods, such as supercritical fluid extraction, pressurized liquid extraction, microwave-assisted extraction, ultrasound-assisted extraction, pulsed-electric field extraction, and enzyme-assisted extraction have emerged as alternatives to conventional methods due to the advantages of the former in terms of smaller solvent consumption, shorter extraction time, and more environment-friendliness. Prior to the extraction step, pretreatment of plant materials to enhance the stability of natural pigments is another important step that must be carefully taken care of. In this paper, a comprehensive review of appropriate pretreatment and extraction methods for chlorophylls, carotenoids, betalains, and anthocyanins, which are major classes of plant pigments, is provided by using pigment stability and extraction yield as assessment criteria.

  6. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  7. Thermal stability test of UO{sub 2}-doped pellet manufactured at INB

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Diogo R., E-mail: diogoribeiro@inb.gov.br [Indústrias Nucleares do Brasil S.A. (FCN/INB), Resende, RJ (Brazil). Fábrica de Combustível Nuclear; Freitas, Artur C., E-mail: artur.freitas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The thermal stability test of UO{sub 2}-doped pellet manufactured at INB was carried out in order to analyze the resintering behavior. This analysis is fundamental for predicting dimensional behavior during irradiation. INB commonly performs resintering test to qualify its production lots, and the same methodology was applied to UO{sub 2}-doped pellets. In this preliminary study, three sets of experiments have been made: 1) without any chemical additive (Z test, the standard UO{sub 2} pellets - undoped); 2) UO{sub 2} pellets doped with 0.1, 0.2 and 0.3 wt% of Al{sub 2}O{sub 3}; and 3) 0.1, 0.2 and 0.3 wt% of Nb{sub 2}O{sub 5}. The preliminary results showed an increase in sintered density in all resintering experiments. So as to obtain the percentage increase, the theoretical densities (g/cm{sup 3} and %TD) were calculated based on the undoped UO{sub 2} pellets. All samples increased in a range of 0.27 to 0.32 %TD the out-pile densification during the resintering process. However, the Z(Nb)3 test showed the lowest value of 0.08 %TD, which is not in agreement with the INB specification limits. The sintered density of this test (0.3 wt% niobia) was 96.15% TD. This fact might be related to the competitive mechanism between Kirkendall effect, forming porosity owing to niobium solubilization on UO{sub 2} matrix, and densification process as a result of uranium diffusivity. Thus, the densification was only 0.08 %TD in Z(Nb)3 sample. All the other samples were in agreement with INB specification. (author)

  8. Stability Tests of Positive Fractional Continuous-time Linear Systems with Delays

    Directory of Open Access Journals (Sweden)

    Tadeusz Kaczorek

    2013-06-01

    Full Text Available Necessary and sufficient conditions for the asymptotic stability of positive fractional continuous-time linear systems with many delays are established. It is shown that: 1 the asymptotic stability of the positive fractional system is independent of their delays, 2 the checking of the asymptotic stability of the positive fractional systems with delays can be reduced to checking of the asymptotic stability of positive standard linear systems without delays.

  9. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  10. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  11. Methodical approaches to solving special problems of testing. Seminar papers

    International Nuclear Information System (INIS)

    1996-01-01

    This Seminar volume introduces concepts and applications from different areas of application of ultrasonic testing and other non-destructive test methods in 18 lectures, in order to give an idea of new trends in development and stimuli for special solutions to problems. 3 articles were recorded separately for the ENERGY data bank. (orig./MM) [de

  12. Fatigue testing of materials under extremal conditions by acoustic method

    NARCIS (Netherlands)

    Baranov, VM; Bibilashvili, YK; Karasevich, VA; Sarychev, GA

    2004-01-01

    Increasing fuel cycle time requires fatigue testing of the fuel clad materials for nuclear reactors. The standard high-temperature fatigue tests are complicated and tedious. Solving this task is facilitated by the proposed acoustic method, which ensures observation of the material damage dynamics,

  13. Cone Penetration Testing: A Sound Method for Urban Archaeological Prospection

    NARCIS (Netherlands)

    Koster, K.

    2015-01-01

    Cone Penetration Testing (CPT) is a geotechnical in situ site investigation method and is widely applied in urbanized areas of the Netherlands. Approximately 20,000 CPTs are conducted in the Netherlands each year. The frequency of such testing, and the presence of archaeological deposits within the

  14. Comparative Evaluation of Modeling Methods for Harmonic Stability Analysis of Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    As the increasing of power electronics based systems, not only the component-based analysis but also a systematic interaction analysis with each other systems are being important. Especially studies about the stability and the harmonics interaction are critical in order to establish the required ...... for the AC-DC converters with a low ratio of switching to the fundamental frequency, and it provides an effective way to reveal the harmonic interaction and stability analysis for the future power electronics based power systems.......As the increasing of power electronics based systems, not only the component-based analysis but also a systematic interaction analysis with each other systems are being important. Especially studies about the stability and the harmonics interaction are critical in order to establish the required...... performance in a power network. However, the traditional small-signal modeling approaches are not enough to represent the complexity of the interaction due to the time varying components of such systems. This paper compares the small-signal modeling methods for harmonic analysis of AC - DC converters...

  15. Repeated Measurement of the Components of Attention with Young Children Using the Attention Network Test: Stability, Isolability, Robustness, and Reliability

    Science.gov (United States)

    Ishigami, Yoko; Klein, Raymond M.

    2015-01-01

    The current study examined the robustness, stability, reliability, and isolability of the attention network scores (alerting, orienting, and executive control) when young children experienced repeated administrations of the child version of the Attention Network Test (ANT; Rueda et al., 2004). Ten test sessions of the ANT were administered to 12…

  16. Study on seismic stability of seawall in man-made island. Pt. 3. Development of evaluation method for seismic stability of seawall considering dynamic interaction of armour embankment and caisson

    International Nuclear Information System (INIS)

    Tochigi, Hitoshi; Kanatani, Mamoru; Kawai, Tadashi

    1999-01-01

    In the development of siting technology for off-shore nuclear power plants on man-made island, assessing the stability of seawall which ensure the safety of backfill ground against ocean waves and earthquakes is indispensable. Concerning the seismic stability of seawall, it is indicated that the evaluation of the influence of lateral pressure of armour embankment acting on the caisson wall is an important factor. We proposed modeling method of discontinuity such as armour unit by distinct element method (DEM) and combined them with caisson type seawall model idealized by FEM. To show the validity of this DEM-FEM hybrid analysis method, the numerical simulation for the shaking table tests was conducted. For the two kinds of seawall model with armour embankment and without the one, the lateral displacement of the seawall induced by sliding of caisson is successfully reproduced and accuracy of above mentioned numerical procedure is confirmed. (author)

  17. Stabilization Methods for the Integration of DAE in the Presence of Redundant Constraints

    International Nuclear Information System (INIS)

    Neto, Maria Augusta; Ambrosio, Jorge

    2003-01-01

    The use of multibody formulations based on Cartesian or natural coordinates lead to sets of differential-algebraic equations that have to be solved. The difficulty in providing compatible initial positions and velocities for a general spatial multibody model and the finite precision of such data result in initial errors that must be corrected during the forward dynamic solution of the system equations of motion.As the position and velocity constraint equations are not explicitly involved in the solution procedure, any integration error leads to the violation of these equations in the long run. Another problem that is very often impossible to avoid is the presence of redundant constraints.Even with no initial redundancy it is possible for some systems to achieve singular configurations in which kinematic constraints become temporarily redundant. In this work several procedures to stabilize the solution of the equations of motion and to handle redundant constraints are revisited. The Baumgarte stabilization, augmented Lagrangian and coordinate partitioning methods are discussed in terms of their efficiency and computational costs. The LU factorization with full pivoting of the Jacobian matrix directs the choice of the set of independent coordinates, required by the coordinate partitioning method.Even when no particular stabilization method is used, a Newton-Raphson iterative procedure is still required in the initial time step to correct the initial positions and velocities, thus requiring the selection of the independent coordinates. However, this initial selection does not guarantee that during the motion of the system other constraints do not become redundant. Two procedures based on the single value decomposition and Gram-Schmidt orthogonalization are revisited for the purpose. The advantages and drawbacks of the different procedures,used separately or in conjunction with each other and their computational costs are finally discussed

  18. A stabilized Runge–Kutta–Legendre method for explicit super-time-stepping of parabolic and mixed equations

    International Nuclear Information System (INIS)

    Meyer, Chad D.; Balsara, Dinshaw S.; Aslam, Tariq D.

    2014-01-01

    in parabolic problems with variable diffusion coefficients. This includes variable coefficient parabolic equations that might give rise to skew symmetric terms. The RKC1 and RKC2 schemes do not share this convex monotonicity preserving property. One-dimensional and two-dimensional von Neumann stability analyses of RKC1, RKC2, RKL1 and RKL2 are also presented, showing that the latter two have some advantages. The paper includes several details to facilitate implementation. A detailed accuracy analysis is presented to show that the methods reach their design accuracies. A stringent set of test problems is also presented. To demonstrate the robustness and versatility of our methods, we show their successful operation on problems involving linear and non-linear heat conduction and viscosity, resistive magnetohydrodynamics, ambipolar diffusion dominated magnetohydrodynamics, level set methods and flux limited radiation diffusion. In a prior paper (Meyer, Balsara and Aslam 2012 [36]) we have also presented an extensive test-suite showing that the RKL2 method works robustly in the presence of shocks in an anisotropically conducting, magnetized plasma

  19. Testing promotes long-term learning via stabilizing activation patterns in a large network of brain areas.

    Science.gov (United States)

    Keresztes, Attila; Kaiser, Daniel; Kovács, Gyula; Racsmány, Mihály

    2014-11-01

    The testing effect refers to the phenomenon that repeated retrieval of memories promotes better long-term retention than repeated study. To investigate the neural correlates of the testing effect, we used event-related functional magnetic resonance imaging methods while participants performed a cued recall task. Prior to the neuroimaging experiment, participants learned Swahili-German word pairs, then half of the word pairs were repeatedly studied, whereas the other half were repeatedly tested. For half of the participants, the neuroimaging experiment was performed immediately after the learning phase; a 1-week retention interval was inserted for the other half of the participants. We found that a large network of areas identified in a separate 2-back functional localizer scan were active during the final recall of the word pair associations. Importantly, the learning strategy (retest or restudy) of the word pairs determined the manner in which the retention interval affected the activations within this network. Recall of previously restudied memories was accompanied by reduced activation within this network at long retention intervals, but no reduction was observed for previously retested memories. We suggest that retrieval promotes learning via stabilizing cue-related activation patterns in a network of areas usually associated with cognitive and attentional control functions. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Validation of an analytical method for quality control and stability study of 10 % Phenylephrine eyedrops

    International Nuclear Information System (INIS)

    Monteagudo Licea, Raiza; Garcia Penna, Caridad Margarita; Botet Garcia, Martha

    2010-01-01

    Phenylephrine is used like mydiatric in eye examinations and other ophthalmic procedures. It is used as vasoconstrictor with local anesthetic agents. In present paper a high resolution liquid chromatography analytical method was validated to quality control and stability studies of 10 % Phenylephrine (eyedrops). Method was based in separation of active principle through a Lichrosorb RO-18 (5 μm) (250 x 4 mm) chromatography column with UV detection at 280 nm using a mobile phase composed by a non-gasified mixture of methanol distilled water (1:1) with 1.1 g of 1-sodium octane-sulphonate by liter adjusted to pH 3,0 with phosphoric acid at a flow speed of 1.0 mL/min. Analytical method was linear, accuracy, specific and exact in the interval of study concentrations