WorldWideScience

Sample records for square cavity filled

  1. Non-homogeneous model for a side heated square cavity filled with a nanofluid

    International Nuclear Information System (INIS)

    Celli, Michele

    2013-01-01

    Highlights: • A side heated two dimensional square cavity filled with a nanofluid is studied. • A non-homogeneous model is taken into account. • The properties of the nanofluid are functions of the fraction of nanoparticles. • Low-Rayleigh numbers yield a non-homogeneous distribution of the nanoparticles. -- Abstract: A side heated two dimensional square cavity filled with a nanofluid is here studied. The side heating condition is obtained by imposing two different uniform temperatures at the vertical boundary walls. The horizontal walls are assumed to be adiabatic and all boundaries are assumed to be impermeable to the base fluid and to the nanoparticles. In order to study the behavior of the nanofluid, a non-homogeneous model is taken into account. The thermophysical properties of the nanofluid are assumed to be functions of the average volume fraction of nanoparticles dispersed inside the cavity. The definitions of the nondimensional governing parameters (Rayleigh number, Prandtl number and Lewis number) are exactly the same as for the clear fluids. The distribution of the nanoparticles shows a particular sensitivity to the low Rayleigh numbers. The average Nusselt number at the vertical walls is sensitive to the average volume fraction of the nanoparticles dispersed inside the cavity and it is also sensitive to the definition of the thermophysical properties of the nanofluid. Highly viscous base fluids lead to a critical behavior of the model when the simulation is performed in pure conduction regime. The solution of the problem is obtained numerically by means of a Galerkin finite element method

  2. Filling a Conical Cavity

    Science.gov (United States)

    Nye, Kyle; Eslam-Panah, Azar

    2016-11-01

    Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.

  3. A water-filled radio frequency accelerating cavity

    International Nuclear Information System (INIS)

    Faehl, R.J.; Keinigs, R.K.; Pogue, E.W.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The objective of this project was to study water-filled resonant cavities as a high-energy density source to drive high-current accelerator configurations. Basic considerations lead to the expectation that a dielectric-filled cavity should be able to store up to e/e o as much energy as a vacuum one with the same dimensions and thus be capable of accelerating a proportionately larger amount of charge before cavity depletion occurs. During this project, we confirmed that water-filled cavities with e/e o = 60-80 did indeed behave with the expected characteristics, in terms of resonant TM modes and cavity Q. We accomplished this result with numerical cavity eigenvalue codes; fully electromagnetic, two-dimensional, particle-in-cell codes; and, most significantly, with scaled experiments performed in water-filled aluminum cavities. The low-power experiments showed excellent agreement with the numerical results. Simulations of the high-field, high-current mode of operation indicated that charged-particle loss on the dielectric windows, which separate the cavity from the beamline, must be carefully controlled to avoid significant distortion of the axial fields

  4. Mixed convection in a lid-driven square cavity with partial slip

    International Nuclear Information System (INIS)

    Ismael, Muneer A.; Pop, Ioan; Chamkha, Ali J.

    2014-01-01

    Steady laminar mixed convection inside a lid-driven square cavity filled with water is studied numerically. The lid is due to the movement of the isothermal top and bottom walls which are maintained at T c and T h , respectively, with T h is higher than T c . A partial slip condition was imposed in these two moving walls. The vertical walls of the cavity are kept adiabatic. The appliance of the numerical analysis was USR finite difference method with upwind scheme treatments of the convective terms included in the momentum and energy equations. The studied relevant parameters were: the partial slip parameter S (0-∞); Richardson number Ri (0.01-100) and the direction of the moving walls (λ t = 1, λ b = ±1). The results have showed that there are critical values for the partial slip parameter at which the convection is declined. (authors)

  5. Acoustic pressure in cavity of variously sized two-dimensional sonic crystals with various filling fractions

    International Nuclear Information System (INIS)

    Wu Liangyu; Chen Lienwen; Liu Chiaming

    2009-01-01

    This study theoretically and experimentally investigates the acoustic pressure in the cavity of a 2D sonic crystal. Such crystals are composed of polymethyl methacrylate cylinders with a square array embedded in air background. The plane wave expansion method and the supercell calculation are employed to calculate the band structure and obtain the defect band. The finite element method is adopted to simulate the pressure field in the sonic crystal and calculate the pressure in the middle of the cavity as a function of frequency. The effects of sizes and filling fractions are investigated, and the quality factor of the cavity is discussed. The measured spectra and pressures in the defect of the sonic crystal demonstrate that the acoustic waves can be localized in the defect at the resonant frequency

  6. Analysis of the Magnetic Field Effect on Entropy Generation at Thermosolutal Convection in a Square Cavity

    Directory of Open Access Journals (Sweden)

    Ammar Ben Brahim

    2011-05-01

    Full Text Available Thermosolutal convection in a square cavity filled with air and submitted to an inclined magnetic field is investigated numerically. The cavity is heated and cooled along the active walls with a mass gradient whereas the two other walls of the cavity are adiabatic and insulated. Entropy generation due to heat and mass transfer, fluid friction and magnetic effect has been determined in transient state for laminar flow by solving numerically the continuity, momentum energy and mass balance equations, using a Control Volume Finite—Element Method. The structure of the studied flows depends on four dimensionless parameters which are the Grashof number, the buoyancy ratio, the Hartman number and the inclination angle. The results show that the magnetic field parameter has a retarding effect on the flow in the cavity and this lead to a decrease of entropy generation, Temperature and concentration decrease with increasing value of the magnetic field parameter.

  7. Study on characteristics of coupled cavity chain filled with plasma

    International Nuclear Information System (INIS)

    Li Jianqing; Xiao Shu; Mo Yuanlong

    2003-01-01

    In this paper, by using rigorous field analysis, a coupled-cavity (CC) chain filled with plasma has been analyzed. How the hybrid wave between the cavity mode and plasma mode is formed has been studied. The periodical CC chain filled with plasma demonstrates periodical TG modes with a cutoff frequency of zero. When the plasma density increase to a large scale, the cavity mode of the CC chain overlaps the TG mode, these two modes couple with each other and form the hybrid modes. In the case of hybrid modes, the 'cold' bandwidth and the 'warm' bandwidth expand, and the coupled impedance increases about 5 times larger than that of the vacuum. As a whole, the slow wave characteristics are improved substantially due to the formation of the hybrid mode

  8. Natural convection in square cavity filled with ferrofluid saturated porous medium in the presence of uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Javed, Tariq [Department of Mathematics and Statistics, FBAS, International Islamic University, Islamabad 44000 (Pakistan); Mehmood, Z., E-mail: rajaziafat@yahoo.com [Department of Mathematics and Statistics, FBAS, International Islamic University, Islamabad 44000 (Pakistan); Abbas, Z. [Department of Mathematics, The Islamia University, Bahawalpur (Pakistan)

    2017-02-01

    This article contains numerical results for free convection through square enclosure enclosing ferrofluid saturated porous medium when uniform magnetic field is applied upon the flow along x-axis. Heat is provided through bottom wall and a square blockage placed near left or right bottom corner of enclosure as a heat source. Left and right vertical boundaries of the cavity are considered insulated while upper wall is taken cold. The problem is modelled in terms of system of nonlinear partial differential equations. Finite element method has been adopted to compute numerical simulations of mathematical problem for wide range of pertinent flow parameters including Rayleigh number, Hartman number, Darcy number and Prandtl number. Analysis of results reveals that the strength of streamline circulation is an increasing function of Darcy and Prandtl number where convection heat transfer is dominant for large values of these parameters whereas increase in Hartman number has opposite effects on isotherms and streamline circulations. Thermal conductivity and hence local heat transfer rate of fluid gets increased when ferroparticles are introduced in the fluid. Average Nusselt number increases with increase in Darcy and Rayleigh numbers while it is decreases when Hartman number is increased.

  9. Natural convection in square cavity filled with ferrofluid saturated porous medium in the presence of uniform magnetic field

    International Nuclear Information System (INIS)

    Javed, Tariq; Mehmood, Z.; Abbas, Z.

    2017-01-01

    This article contains numerical results for free convection through square enclosure enclosing ferrofluid saturated porous medium when uniform magnetic field is applied upon the flow along x-axis. Heat is provided through bottom wall and a square blockage placed near left or right bottom corner of enclosure as a heat source. Left and right vertical boundaries of the cavity are considered insulated while upper wall is taken cold. The problem is modelled in terms of system of nonlinear partial differential equations. Finite element method has been adopted to compute numerical simulations of mathematical problem for wide range of pertinent flow parameters including Rayleigh number, Hartman number, Darcy number and Prandtl number. Analysis of results reveals that the strength of streamline circulation is an increasing function of Darcy and Prandtl number where convection heat transfer is dominant for large values of these parameters whereas increase in Hartman number has opposite effects on isotherms and streamline circulations. Thermal conductivity and hence local heat transfer rate of fluid gets increased when ferroparticles are introduced in the fluid. Average Nusselt number increases with increase in Darcy and Rayleigh numbers while it is decreases when Hartman number is increased.

  10. Cavity air flow behavior during filling in microinjection molding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2011-01-01

    Process monitoring of microinjection molding (μ-IM) is of crucial importance in understanding the effects of different parameter settings on the process, especially on its performance and consistency with regard to parts' quality. Quality factors related to mold cavity air evacuation can provide...... valuable information about the process dynamics and also about the filling of a cavity by a polymer melt. In this paper, a novel experimental setup is proposed to monitor maximum air flow and air flow work as an integral of the air flow over time by employing a microelectromechanical system gas sensor...... the effects of process parameters on cavity air evacuation, and the influence of air evacuation on the part flow length. © 2011 American Society of Mechanical Engineers....

  11. High current electron beam acceleration in dielectric-filled RF cavities

    International Nuclear Information System (INIS)

    Faehl, R.J.; Keinigs, R.K.

    1996-01-01

    The acceleration of charged particles in radio frequency (RF) cavities is a widely used mode in high energy accelerators. Advantages include very high accelerating gradients and very stable phase control. A traditional limitation for such acceleration has been their use for intense, high current beam generation. This constraint arises from the inability to store a large amount of electromagnetic energy in the cavity and from loading effects of the beam on the cavity. The authors have studied a simple modification to transcend these limitations. Following Humphries and Huang, they have conducted analytic and numerical investigations of RF accelerator cavities in which a high dielectric constant material, such as water, replaces most of the cavity volume. This raises the stored energy in a cavity of given dimensions by a factor var-epsilon/var-epsilon 0 . For a water fill, var-epsilon/var-epsilon 0 ∼ 80, depending on the frequency. This introduction of high dielectric constant material into the cavity reduces the resonant frequencies by a factor of (var-epsilon/var-epsilon 0 ) 1/2 . This reduced operating frequency mans that existing high efficiency power supplies, at lower frequencies, can be used for an accelerator

  12. Study of Electron Swarm in High Pressure Hydrogen Gas Filled RF Cavities

    International Nuclear Information System (INIS)

    Yonehara, K.; Chung, M.; Jansson, A.; Moretti, A.; Popovic, M.; Tollestrup, A.; Alsharo'a, M.; Johnson, R.P.; Notani, M.; Oka, T.; Wang, H.

    2010-01-01

    A high pressure hydrogen gas filled RF cavity has been proposed for use in the muon collection system for a muon collider. It allows for high electric field gradients in RF cavities located in strong magnetic fields, a condition frequently encountered in a muon cooling channel. In addition, an intense muon beam will generate an electron swarm via the ionization process in the cavity. A large amount of RF power will be consumed into the swarm. We show the results from our studies of the HV RF breakdown in a cavity without a beam and present some results on the resulting electron swarm dynamics. This is preliminary to actual beam tests which will take place late in 2010.

  13. Evaluation of cavity size, kind, and filling technique of composite shrinkage by finite element.

    Science.gov (United States)

    Jafari, Toloo; Alaghehmad, Homayoon; Moodi, Ehsan

    2018-01-01

    Cavity preparation reduces the rigidity of tooth and its resistance to deformation. The purpose of this study was to evaluate the dimensional changes of the repaired teeth using two types of light cure composite and two methods of incremental and bulk filling by the use of finite element method. In this computerized in vitro experimental study, an intact maxillary premolar was scanned using cone beam computed tomography instrument (SCANORA, Switzerland), then each section of tooth image was transmitted to Ansys software using AUTOCAD. Then, eight sizes of cavity preparations and two methods of restoration (bulk and incremental) using two different types of composite resin materials (Heliomolar, Brilliant) were proposed on software and analysis was completed with Ansys software. Dimensional change increased by widening and deepening of the cavities. It was also increased using Brilliant composite resin and incremental filling technique. Increase in depth and type of filling technique has the greatest role of dimensional change after curing, but the type of composite resin does not have a significant role.

  14. MHD natural convection in open inclined square cavity with a heated circular cylinder

    Science.gov (United States)

    Hosain, Sheikh Anwar; Alim, M. A.; Saha, Satrajit Kumar

    2017-06-01

    MHD natural convection in open cavity becomes very important in many scientific and engineering problems, because of it's application in the design of electronic devices, solar thermal receivers, uncovered flat plate solar collectors having rows of vertical strips, geothermal reservoirs, etc. Several experiments and numerical investigations have been presented for describing the phenomenon of natural convection in open cavity for two decades. MHD natural convection and fluid flow in a two-dimensional open inclined square cavity with a heated circular cylinder was considered. The opposite wall to the opening side of the cavity was first kept to constant heat flux q, at the same time the surrounding fluid interacting with the aperture was maintained to an ambient temperature T∞. The top and bottom wall was kept to low and high temperature respectively. The fluid with different Prandtl numbers. The properties of the fluid are assumed to be constant. As a result a buoyancy force is created inside the cavity due to temperature difference and natural convection is formed inside the cavity. The Computational Fluid Dynamics (CFD) code are used to discretize the solution domain and represent the numerical result to graphical form.. Triangular meshes are used to obtain the solution of the problem. The streamlines and isotherms are produced, heat transfer parameter Nu are obtained. The results are presented in graphical as well as tabular form. The results show that heat flux decreases for increasing inclination of the cavity and the heat flux is a increasing function of Prandtl number Pr and decreasing function of Hartmann number Ha. It is observed that fluid moves counterclockwise around the cylinder in the cavity. Various recirculations are formed around the cylinder. The almost all isotherm lines are concentrated at the right lower corner of the cavity. The object of this work is to develop a Mathematical model regarding the effect of MHD natural convection flow around

  15. Non-gray gas radiation effect on mixed convection in lid driven square cavity

    Energy Technology Data Exchange (ETDEWEB)

    Cherifi, Mohammed, E-mail: production1998@yahoo.fr; Benbrik, Abderrahmane, E-mail: abenbrik@umbb.dz; Laouar-Meftah, Siham, E-mail: laouarmeftah@gmail.com [M’Hamed Bougara University, Faculty of Hydrocarbons and Chemistry, 35000 Boumerdes (Algeria); Lemonnier, Denis, E-mail: denis.lemonnier@ensma.fr [Institut Pprime, CNRS, ENSMA, University of Poitiers, Poitiers Futuroscope (France)

    2016-06-02

    A numerical study is performed to investigate the effect of non-gray radiation on mixed convection in a vertical two sided lid driven square cavity filled with air-H{sub 2}O-CO{sub 2} gas mixture. The vertical moving walls of the enclosure are maintained at two different but uniform temperatures. The horizontal walls are thermally insulated and considered as adiabatic walls. The governing differential equations are solved by a finite-volume method and the SIMPLE algorithm was adopted to solve the pressure–velocity coupling. The radiative transfer equation (RTE) is solved by the discrete ordinates method (DOM). The spectral line weighted sum of gray gases model (SLW) is used to account for non-gray radiation properties. Simulations are performed in configurations where thermal and shear forces induce cooperating buoyancy forces. Streamlines, isotherms, and Nusselt number are analyzed for three different values of Richardson’s number (from 0.1 to 10) and by considering three different medium (transparent medium, gray medium using the Planck mean absorption coefficient, and non-gray medium assumption).

  16. THEORETICAL GAS CONCENTRATIONS ACHIEVING 100% FILL OF THE VITREOUS CAVITY IN THE POSTOPERATIVE PERIOD: A Gas Eye Model Study.

    Science.gov (United States)

    Williamson, Tom H; Guillemaut, Jean-Yves; Hall, Sheldon K; Hutter, Joseph C; Goddard, Tony

    2017-12-11

    To determine the concentrations of different gas tamponades in air to achieve 100% fill of the vitreous cavity postoperatively and to examine the influence of eye volume on these concentrations. A mathematical model of the mass transfer dynamics of tamponade and blood gases (O2, N2, and CO2) when injected into the eye was used. Mass transfer surface areas were calculated from published anatomical data. The model has been calibrated from published volumetric decay and composition results for three gases sulphahexafluoride (SF6), hexafluoroethane (C2F6), or perfluoropropane (C3F8). The concentrations of these gases (in air) required to achieve 100% fill of the vitreous cavity postoperatively without an intraocular pressure rise were determined. The concentrations were calculated for three volumes of the vitreous cavity to test whether ocular size influenced the results. A table of gas concentrations was produced. In a simulation of pars plana vitrectomy operations in which an 80% to 85% fill of the vitreous cavity with gas was achieved at surgery, the concentrations of the 3 gases in air to achieve 100% fill postoperatively were 10% to 13% for C3F8, 12% to 15% for C2F6, and 19% to 25% for SF6. These were similar to the so-called "nonexpansive" concentrations used in the clinical setting. The calculations were repeated for three different sizes of eye. Aiming for an 80% fill at surgery and 100% postoperatively, an eye with a 4-mL vitreous cavity required 24% SF6, 15% C2F6, or 13% C3F8; 7.2 mL required 25% SF6, 15% C2F6, or 13% C3F8; and 10 mL required 25% SF6, 16% C2F6, or 13% C3F8. When using 100% gas (e.g., used in pneumatic retinopexy), to achieve 100% fill postoperatively, the minimum vitreous cavity fill at surgery was 43% for SF6, 29% for C2F6, and 25% for C3F8 and was only minimally changed by variation in the size of the eye. A table has been produced, which could be used for surgical innovation in gas usage in the vitreous cavity. It provides concentrations

  17. Subharmonic generation, chaos, and subharmonic resurrection in an acoustically driven fluid-filled cavity.

    Science.gov (United States)

    Cantrell, John H; Adler, Laszlo; Yost, William T

    2015-02-01

    Traveling wave solutions of the nonlinear acoustic wave equation are obtained for the fundamental and second harmonic resonances of a fluid-filled cavity. The solutions lead to the development of a non-autonomous toy model for cavity oscillations. Application of the Melnikov method to the model equation predicts homoclinic bifurcation of the Smale horseshoe type leading to a cascade of period doublings with increasing drive displacement amplitude culminating in chaos. The threshold value of the drive displacement amplitude at tangency is obtained in terms of the acoustic drive frequency and fluid attenuation coefficient. The model prediction of subharmonic generation leading to chaos is validated from acousto-optic diffraction measurements in a water-filled cavity using a 5 MHz acoustic drive frequency and from the measured frequency spectrum in the bifurcation cascade regime. The calculated resonant threshold amplitude of 0.2 nm for tangency is consistent with values estimated for the experimental set-up. Experimental evidence for the appearance of a stable subharmonic beyond chaos is reported.

  18. An Evaluation of GuttaFlow2 in Filling Artificial Internal Resorption Cavities: An in vitro Study.

    Science.gov (United States)

    Mohammad, Yara; Alafif, Hisham; Hajeer, Mohammad; Yassin, Oula

    2016-06-01

    Obturation of root canal with internal resorption represents a major challenge in Endodontics. In spite of that, usual obturation techniques are often employed without considering the best technique to solve this problem. The goal of this study was to investigate the ability of GuttaFlow2 in filling artificial internal resorption cavities. The study sample included 36 human upper central incisors that were prepared using Protaper system (F4). Internal resorption cavities were prepared by cutting each tooth at 7 mm from the apex and preparing hemispherical cavities on both the sides and then re-attaching them. The sample was randomly separated into three groups (n = 12 in each group). In the first group, thermal injection technique (Obtura II) was employed and served as the control group. In the second group, injection of cold free-flow obturation technique with a master cone (GF2-C) was employed, whereas in the third group injection of cold free-flow obturation without a master cone (GF2) was followed. The teeth were re-cut at the same level as before and examined under a stereomicroscope. Subsequently, the captured images were transferred to AutoCAD program to measure the percentage of total filling "TF," gutta-percha "G," sealer "S," and voids "V" out of the total surface of the cross sections. All materials showed high filling properties in terms of "total filling," ranging from 99.17% (for Obtura II) to 99.72% (for GF2-C). Regarding gutta-percha percentages of filling, they ranged from 83.15 to 83.93%, whereas those for the sealer ranged from 5.71 to 15.24%. GuttaFlow2 group with a master cone appeared to give the best results despite the insignificant differences among the three groups. The GuttaFlow2 with a master cone technique seemed to be a promising filling material and gave results similar to those observed with Obtura II. It is recommended for use to obturate internal resorption cavities in clinical practice due to its good adaptability to root canal

  19. Asymptotic solution of natural convection problem in a square cavity heated from below

    NARCIS (Netherlands)

    Grundmann, M; Mojtabi, A; vantHof, B

    Studies a two-dimensional natural convection in a porous, square cavity using a regular asymptotic development in powers of the Rayleigh number. Carries the approximation through to the 34th order. Analyses convergence of the resulting series for the Nusselt number in both monocellular and

  20. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ismael, Muneer A. [Mechanical Engineering Department, Engineering College, University of Basrah, Basrah (Iraq); Mansour, M.A. [Department of Mathematics, Assuit University, Faculty of Science, Assuit (Egypt); Chamkha, Ali J. [Mechanical Engineering Department, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Prince Sultan Endowment for Energy and Environment, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Rashad, A.M., E-mail: am_rashad@yahoo.com [Department of Mathematics, Aswan University, Faculty of Science, Aswan 81528 (Egypt)

    2016-10-15

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  1. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    International Nuclear Information System (INIS)

    Ismael, Muneer A.; Mansour, M.A.; Chamkha, Ali J.; Rashad, A.M.

    2016-01-01

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  2. Behavior of a heavy cylinder in a horizontal cylindrical liquid-filled cavity at modulated rotation

    International Nuclear Information System (INIS)

    Kozlov, Nikolai V; Vlasova, Olga A

    2016-01-01

    The behavior of a heavy cylindrical solid in a horizontal cylindrical cavity is experimentally investigated. The cavity is filled with a viscous liquid and rotates. Two rotation regimes are considered. The first one is steady rotation. A number of body motion regimes are found depending on the cavity rotation speed. The second regime is a modulated rotation, in which the rotation speed is varying periodically. It can be presented as a sum of steady rotation and librations. On the whole, three different cases of the body repulsion from the cavity wall are observed. In the first case, the repulsion occurs when the body slides over a rotating cavity wall. In the second case, the body being in the centrifuged state—when it rotates with the fluid—detaches from the cavity wall under the action of gravity. In the third case, at librations, the wall performs oscillations and the body is repulsed from the wall due to the nonlinear viscous interaction with the fluid. (paper)

  3. Study of turbulent natural convection in a tall differentially heated cavity filled with either non-participating, participating grey and participating semigrey media

    International Nuclear Information System (INIS)

    Capdevila, R; Perez-Segarra, C D; Lehmkuhl, O; Colomer, G

    2012-01-01

    Turbulent natural convection in a tall differentially heated cavity of aspect ratio 5:1, filled with air under a Rayleigh number based on the height of 4.5·10 10 is studied numerically. Three different situations have been analysed. In the first one, the cavity is filled with a transparent medium. In the second one, the cavity is filled with a semigrey participating mixture of air and water vapour. In the last one the cavity contains a grey participating gas. The turbulent flow is described by means of Large Eddy Simulation (LES) using symmetry-preserving discretizations. Simulations are compared with experimental data available in the literature and with Direct Numerical Simulations (DNS). Surface and gas radiation have been simulated using the Discrete Ordinates Method (DOM). The influence of radiation on fluid flow behaviour has been analysed.

  4. Nd:YAG laser in endodontics: filling-material edge bordering on a root channel laser cavity

    Science.gov (United States)

    Belikov, Andrei V.; Sinelnik, Yuri A.; Moroz, Boris T.; Pavlovskaya, Irina V.

    1997-12-01

    For the very first time it is represented a study of filling material edge bordering upon root channel cavity modified with a laser. As a filling material it is used a glass ionomer cement. It is demonstrated that Nd:YAG laser radiation effects on increase of grade of edge bordering on the average of 20 - 30% at temperature rise of no more than 2 - 3 degrees in periodontium area in a period of operation.

  5. Some examples of the cavity filling along transportation routes above abandoned room and pillar lignite Mines in Tokai Region

    International Nuclear Information System (INIS)

    Sakamoto, A.; Yamada, N.; Sugiura, K.; Kawamoto, T.

    2005-01-01

    The authors describe the applications of the integrated cavity filling technique to abandoned lignite mines in Tokai region. These abandoned lignite mines were in operation until 1960's and the routes of Tokai By-Pass Expressway and the linear motor car railway line for Aichi Exposition pass over these abandoned mines. Since the size of abandoned mines were much larger than the route of the expressway and the elevated monorail, limited areas relevant to their stability had to be only filled. This article describe the details of cavity filling operations in these two projects, which may be some valuable examples for assessing the methods how to deal problems associated with mine closures in long term. (authors)

  6. Turbulent natural convection in a differentially heated cavity of aspect ratio 5 filled with non-participating and participating grey media

    International Nuclear Information System (INIS)

    Capdevila, R; Trias, F X; Pérez-Segarra, C D; Lehmkuhl, O; Colomer, G

    2011-01-01

    In the present work, turbulent natural convection in a tall differentially heated cavity of aspect ratio 5:1, filled with air (Pr = 0.7) under a Rayleigh number based on the height of 4.5 · 10 10 , is studied numerically. Two different situations have been analysed. In the first one, the cavity is filled with a transparent medium. In the second one, the cavity contains a grey participating gas. The turbulent flow is described by means of Large Eddy Simulation (LES) using symmetry-preserving discretizations. Simulations are compared with experimental data available in the literature and with Direct Numerical Simulations (DNS). Surface and gas radiation have been simulated using the Discrete Ordinates Method (DOM). The influence of radiation on fluid flow behaviour has also been analysed.

  7. Conduction and convection heat transfer characteristics of water-based au nanofluids in a square cavity with differentially heated side walls subjected to constant temperatures

    Directory of Open Access Journals (Sweden)

    Ternik Primož

    2014-01-01

    Full Text Available The present work deals with the natural convection in a square cavity filled with the water-based Au nanofluid. The cavity is heated on the vertical and cooled from the adjacent wall, while the other two horizontal walls are adiabatic. The governing differential equations have been solved by the standard finite volume method and the hydrodynamic and thermal fields were coupled together using the Boussinesq approximation. The main objective of this study is to investigate the influence of the nanoparticles’ volume fraction on the heat transfer characteristics of Au nanofluids at the given base fluid’s (i.e. water Rayleigh number. Accurate results are presented over a wide range of the base fluid Rayleigh number and the volume fraction of Au nanoparticles. It is shown that adding nanoparticles in a base fluid delays the onset of convection. Contrary to what is argued by many authors, we show by numerical simulations that the use of nanofluids can reduce the heat transfer rate instead of increasing it.

  8. Parametric Study of Fire Performance of Concrete Filled Hollow Steel Section Columns with Circular and Square Cross-Section

    Science.gov (United States)

    Nurfaidhi Rizalman, Ahmad; Tahir, Ng Seong Yap Mahmood Md; Mohammad, Shahrin

    2018-03-01

    Concrete filled hollow steel section column have been widely accepted by structural engineers and designers for high rise construction due to the benefits of combining steel and concrete. The advantages of concrete filled hollow steel section column include higher strength, ductility, energy absorption capacity, and good structural fire resistance. In this paper, comparison on the fire performance between circular and square concrete filled hollow steel section column is established. A three-dimensional finite element package, ABAQUS, was used to develop the numerical model to study the temperature development, critical temperature, and fire resistance time of the selected composite columns. Based on the analysis and comparison of typical parameters, the effect of equal cross-sectional size for both steel and concrete, concrete types, and thickness of external protection on temperature distribution and structural fire behaviour of the columns are discussed. The result showed that concrete filled hollow steel section column with circular cross-section generally has higher fire resistance than the square section.

  9. Conjugate heat transfer in a porous cavity filled with nano-fluids and heated by a triangular thick wall

    International Nuclear Information System (INIS)

    Chamkha, Ali J.; Ismael, Muneer A.

    2013-01-01

    The conjugate natural convection-conduction heat transfer in a square domain composed of nano-fluids filled porous cavity heated by a triangular solid wall is studied under steady-state conditions. The vertical and horizontal walls of the triangular solid wall are kept isothermal and at the same hot temperature Th. The other boundaries surrounding the porous cavity are kept adiabatic except the right vertical wall where it is kept isothermally at the lower temperature T c . Equations governing the heat transfer in the triangular wall and heat and nano-fluid flow, based on the Darcy model, in the nano-fluid-saturated porous medium together with the derived relation of the interface temperature are solved numerically using the over-successive relaxation finite-difference method. A temperature independent nano-fluids properties model is adopted. Three nano-particle types dispersed in one base fluid (water) are investigated. The investigated parameters are the nano-particles volume fraction φ (0-0.2), Rayleigh number Ra (10-1000), solid wall to base-fluid saturated porous medium thermal conductivity ratio K ro (0.44, 1, 23.8), and the triangular wall thickness D (0.1-1). The results are presented in the conventional form; contours of streamlines and isotherms and the local and average Nusselt numbers. At a very low Rayleigh number Ra = 10, a significant enhancement in heat transfer within the porous cavity with φ is observed. Otherwise, the heat transfer may be enhanced or deteriorated with φ depending on the wall thickness D and the Rayleigh number Ra. At high Rayleigh numbers and low conductivity ratios, critical values of D, regardless of 4, are observed and accounted. (authors)

  10. Turbulent natural convection in a differentially heated cavity of aspect ratio 5 filled with non-participating and participating grey media

    Energy Technology Data Exchange (ETDEWEB)

    Capdevila, R; Trias, F X; Perez-Segarra, C D [Centre Tecnologic de Transferencia de Calor (CTTC), Lab.Termotecnia i Energetica, Universitat Politecnica de Catalunya (UPC), C/Colom, 11, E08222 Terrassa, Barcelona (Spain); Lehmkuhl, O; Colomer, G, E-mail: cttc@cttc.upc.edu, E-mail: termofluids@termofluids.com [Termofluids, S. L., Magi Colet 8, E08204 Sabadell, Barcelona (Spain)

    2011-12-22

    In the present work, turbulent natural convection in a tall differentially heated cavity of aspect ratio 5:1, filled with air (Pr = 0.7) under a Rayleigh number based on the height of 4.5 {center_dot} 10{sup 10}, is studied numerically. Two different situations have been analysed. In the first one, the cavity is filled with a transparent medium. In the second one, the cavity contains a grey participating gas. The turbulent flow is described by means of Large Eddy Simulation (LES) using symmetry-preserving discretizations. Simulations are compared with experimental data available in the literature and with Direct Numerical Simulations (DNS). Surface and gas radiation have been simulated using the Discrete Ordinates Method (DOM). The influence of radiation on fluid flow behaviour has also been analysed.

  11. Combined Natural Convection and Radiation Heat Transfer of Various Absorbing-Emitting-Scattering Media in a Square Cavity

    Directory of Open Access Journals (Sweden)

    Xianglong Liu

    2014-01-01

    Full Text Available A numerical model is developed to simulate combined natural convection and radiation heat transfer of various anisotropic absorbing-emitting-scattering media in a 2D square cavity based on the discrete ordinate (DO method and Boussinesq assumption. The effects of Rayleigh number, optical thickness, scattering ratio, scattering phase function, and aspect ratio of square cavity on the behaviors of heat transfer are studied. The results show that the heat transfer of absorbing-emitting-scattering media is the combined results of radiation and natural convection, which depends on the physical properties and the aspect ratio of the cavity. When the natural convection becomes significant, the convection heat transfer is enhanced, and the distributions of NuR and Nuc along the walls are obviously distorted. As the optical thickness increases, NuR along the hot wall decreases. As the scattering ratio decreases, the NuR along the walls decreases. At the higher aspect ratio, the more intensive thermal radiation and natural convection are formed, which increase the radiation and convection heat fluxes. This paper provides the theoretical research for the optimal thermal design and practical operation of the high temperature industrial equipments.

  12. Dental Stem Cell Migration on Pulp Ceiling Cavities Filled with MTA, Dentin Chips, or Bio-Oss

    Directory of Open Access Journals (Sweden)

    Stefania Lymperi

    2015-01-01

    Full Text Available MTA, Bio-Oss, and dentin chips have been successfully used in endodontics. The aim of this study was to assess the adhesion and migration of dental stem cells on human pulp ceiling cavities filled with these endodontic materials in an experimental model, which mimics the clinical conditions of regenerative endodontics. Cavities were formed, by a homemade mold, on untouched third molars, filled with endodontic materials, and observed with electron microscopy. Cells were seeded on cavities’ surface and their morphology and number were analysed. The phenomenon of tropism was assessed in a migration assay. All three materials demonstrated appropriate microstructures for cell attachment. Cells grew on all reagents, but they showed a differential morphology. Moreover, variations were observed when comparing cells numbers on cavity’s filling versus the surrounding dentine disc. The highest number of cells was recorded on dentin chips whereas the opposite was true for Bio-Oss. This was confirmed in the migration assay where a statistically significant lower number of cells migrated towards Bio-Oss as compared to MTA and dentin chips. This study highlights that MTA and dentin chips have a greater potential compared to Bio-Oss regarding the attraction of dental stem cells and are good candidates for bioengineered pulp regeneration.

  13. Dark localized structures in a cavity filled with a left-handed material

    International Nuclear Information System (INIS)

    Tlidi, Mustapha; Kockaert, Pascal; Gelens, Lendert

    2011-01-01

    We consider a nonlinear passive optical cavity filled with left-handed and right-handed materials and driven by a coherent injected beam. We assume that both left-handed and right-handed materials possess a Kerr focusing type of nonlinearity. We show that close to the zero-diffraction regime, high-order diffraction allows us to stabilize dark localized structures in this device. These structures consist of dips in the transverse profile of the intracavity field and do not exist without high-order diffraction. We analyze the snaking bifurcation diagram associated with these structures. Finally, a realistic estimation of the model parameters is provided.

  14. How to Fill the Cavity after Curettage of Giant Cell Tumors around the Knee? A Multicenter Analysis

    Directory of Open Access Journals (Sweden)

    Kai Zheng

    2017-01-01

    Conclusions: Parameters including patients' age, gender, tumor location, and radiological classification did not affect surgeons' treatments in cavity filling after GCT curettage. Cementation should be recommended because of easy usage, the similar postoperative knee function with bone grafting, and the better local tumor control than bone grafting.

  15. Ultrasensitive Mach-Zehnder Interferometric Temperature Sensor Based on Liquid-Filled D-Shaped Fiber Cavity

    Directory of Open Access Journals (Sweden)

    Hui Zhang

    2018-04-01

    Full Text Available A liquid-filled D-shaped fiber (DF cavity serving as an in-fiber Mach–Zehnder interferometer (MZI has been proposed and experimentally demonstrated for temperature sensing with ultrahigh sensitivity. The miniature MZI is constructed by splicing a segment of DF between two single-mode fibers (SMFs to form a microcavity (MC for filling and replacement of various refractive index (RI liquids. By adjusting the effective RI difference between the DF and MC (the two interference arms, experimental and calculated results indicate that the interference spectra show different degrees of temperature dependence. As the effective RI of the liquid-filled MC approaches that of the DF, temperature sensitivity up to −84.72 nm/°C with a linear correlation coefficient of 0.9953 has been experimentally achieved for a device with the MC length of 456 μm, filled with liquid RI of 1.482. Apart from ultrahigh sensitivity, the proposed MCMZI device possesses additional advantages of its miniature size and simple configuration; these features make it promising and competitive in various temperature sensing applications, such as consumer electronics, biological treatments, and medical diagnosis.

  16. Ultrasensitive Mach-Zehnder Interferometric Temperature Sensor Based on Liquid-Filled D-Shaped Fiber Cavity.

    Science.gov (United States)

    Zhang, Hui; Gao, Shecheng; Luo, Yunhan; Chen, Zhenshi; Xiong, Songsong; Wan, Lei; Huang, Xincheng; Huang, Bingsen; Feng, Yuanhua; He, Miao; Liu, Weiping; Chen, Zhe; Li, Zhaohui

    2018-04-17

    A liquid-filled D-shaped fiber (DF) cavity serving as an in-fiber Mach–Zehnder interferometer (MZI) has been proposed and experimentally demonstrated for temperature sensing with ultrahigh sensitivity. The miniature MZI is constructed by splicing a segment of DF between two single-mode fibers (SMFs) to form a microcavity (MC) for filling and replacement of various refractive index (RI) liquids. By adjusting the effective RI difference between the DF and MC (the two interference arms), experimental and calculated results indicate that the interference spectra show different degrees of temperature dependence. As the effective RI of the liquid-filled MC approaches that of the DF, temperature sensitivity up to −84.72 nm/°C with a linear correlation coefficient of 0.9953 has been experimentally achieved for a device with the MC length of 456 μm, filled with liquid RI of 1.482. Apart from ultrahigh sensitivity, the proposed MCMZI device possesses additional advantages of its miniature size and simple configuration; these features make it promising and competitive in various temperature sensing applications, such as consumer electronics, biological treatments, and medical diagnosis.

  17. Ice-water convection in an inclined rectangular cavity filled with a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X. (Dept. of Mechanical Engineering, Ecole Polytechnique de Montreal (Canada)); Kahawita, R. (Dept. of Civil Engineering, Ecole Polytechnique de Montreal (Canada))

    1994-10-01

    This paper reports on the results of a numerical study on the equilibrium state of the convection of water in the presence of ice in an inclined rectangular cavity filled with a porous medium. One side of the cavity is maintained at a temperature higher than the fusion temperature while the opposite side is cooled to a temperature lower than the fusion temperature. The two remaining sides are insulated. Results are analysed in terms of the density inversion parameter, the tilt angle, and the cooling temperature. It appears that the phenomenon of density inversion plays an important role in the equilibrium of an ice-water system when the heating temperature is below 20 . In a vertical cavity, the density inversion causes the formation of two counter-rotating vortices leading to a water volume which is wider at the bottom than at the top. When the cavity is inclined, there exist two branches of solutions which exhibit the bottom heating and the side heating characteristics, respectively (the Benard and side heating branches). Due to the inversion of density, the solution on the Benard branch may fail to converge to a steady state at small tilt angles and exhibits an oscillating behavior. On the side heating branch, a maximum heat transfer rate is obtained at a tilt angle of about 70 but the water volume was found to depend very weakly on the inclination of the cavity. Under the effect of subcooling, the interplay between conduction in the solid phase and convection in the liquid leads to an equilibrium ice-water interface which is most distorted at some intermediate cooling temperature. (orig.)

  18. Radiative effects on turbulent buoyancy-driven air flow in open square cavities

    International Nuclear Information System (INIS)

    Zamora, B.; Kaiser, A.S.

    2016-01-01

    The effects of the radiative effects and the air variable properties (density, viscosity and thermal conductivity) on the buoyancy-driven flows established in open square cavities are investigated. Two-dimensional, laminar, transitional and turbulent simulations are obtained, considering both uniform wall temperature and uniform heat flux heating conditions. In transitional and turbulent cases, the low- Reynolds k-ω turbulence model is employed. The average Nusselt number and the dimensionless mass-flow rate have been obtained for a wide range of the Rayleigh number varying from 10 3 to 10 16 . The results obtained taking into account the variable thermophysical properties of air are compared to those calculated assuming constant properties and the Boussinesq approximation. In addition, the influence of considering surface radiative effects on the differences reached for the Nusselt number and the mass flow rate obtained with several intensities of heating is studied; specifically, the effects of thermal radiation on the appearance of the burnout phenomenon is analyzed. The changes produced in the flow patterns into the cavity when the radiative heat transfer and the effects of variation of properties are relevant, are also shown. (authors)

  19. Filling material for a buried cavity in a collapse area using light-weighted foam and active feldspar

    Science.gov (United States)

    Cho, Jin Woo; Lee, Ju-hyoung; Kim, Sung-Wook; Choi, Eun-Kyeong

    2017-04-01

    Concrete which is generally used as filling material for a buried cavity has very high strength but significantly high self-load is considered its disadvantage. If it is used as filling material, the second collapse due to additional load, causing irreversible damage. If light-weighted foam and active feldspar are used to solve this problem, the second collapse can be prevented by reducing of self-load of filling material. In this study, the specimen was produced by mixing light-weighted foam, active feldspar and cement, and changes in the density, unconfined compressive strength and hydraulic conductivity were analyzed. Using the light-weighted foam could enable the adjustment of density of specimen between 0.5 g/cm3 and 1.7 g/cm3, and if the mixing ratio of the light-weighted foam increases, the specimen has more pores and smaller range of cross-sectional area. It is confirmed that it has direct correlation with the density, and if the specimen has more pores, the density of the specimen is lowered. The density of the specimen influences the unconfined compressive strength and the hydraulic conductivity, and it was also confirmed that the unconfined compressive strength could be adjusted between 0.6 MPa and 8 MPa and the hydraulic conductivity could be adjusted between 10-9cm/sec and 10-3cm/sec. These results indicated that we can adjust unconfined compressive strength and hydraulic conductivity of filling materials by changing the mixing amount of lightweight-weighted foam according to the requirements of the field condition. Keywords: filling material, buried cavity, light-weighted foam, feldspar Acknowledgement This research was supported by a Grant from a Strategic Research Project (Horizontal Drilling and Stabilization Technologies for Urban Search and Rescue (US&R) Operation) funded by the Korea Institute of Civil Engineering and Building Technology.

  20. Nusselt-Rayleigh correlations for design of industrial elements: Experimental and numerical investigation of natural convection in tilted square air filled enclosures

    International Nuclear Information System (INIS)

    Bairi, A.

    2008-01-01

    Natural convection in air filled 2D tilted square cavities is experimentally and numerically studied. The hot and cold walls of the cavity are maintained isothermal at temperatures T h and T c , respectively, and the channel of the cavity is adiabatic. Measurements and simulations are performed for various geometrical and thermal configurations. Different values of the Rayleigh number Ra and the tilt angle α of the cavity are considered. The range of Ra covered in our work extends from 10 to 10 10 while α varies from 0 to 360 deg. This permits the analysis of several significant situations corresponding to vertical active walls (α 0 deg.), hot wall at the bottom (α = 90 deg.; Rayleigh-Benard convection) and hot wall at the top, pure conductive mode (α = 270 deg.). A computational 2D model based on the finite volume method is used for solving the mass, momentum and energy transfer governing equations. The simulation provides thermal and dynamic maps of the fluid for all configurations treated. The influence of Ra and α on the flow pattern and on the convective heat transfer are analysed and discussed. The thermal boundary distribution and the convective heat transfer calculated are, for most treated cases, close to those obtained experimentally by means of a simple bench specifically designed for this purpose. The maximum discrepancy between the simulations and measurements is relatively small, corresponding to the expected uncertainty of the model and measurements. The convective heat transfer is determined while calculating the radiative and conductive contributions to the global exchange. Radiation is determined by the radiosity method associated with the measured field of temperatures as well as to the global IR emissivities of all the internal elements of the cavity. The average Nusselt number Nu-bar is used to quantify the calculated convective contribution of the heat exchange within the cavity, and is compared with the measured value Nu-bar m . We

  1. About the stability of the rotational motion of a top with a cavity filled up with a viscous fluid

    International Nuclear Information System (INIS)

    Parada, R.F.; Collar, A.F.

    1995-09-01

    The linear stability problem of the rotational motion of a top around a fixed point containing an inner cavity filled up with a viscous fluid is considered. The effect of the viscosity in the stability problem is studied. (author). 15 refs

  2. Numerical simulation of magnetic convection ferrofluid flow in a permanent magnet-inserted cavity

    Science.gov (United States)

    Ashouri, Majid; Behshad Shafii, Mohammad

    2017-11-01

    The magnetic convection heat transfer in an obstructed two-dimensional square cavity is investigated numerically. The walls of the cavity are heated with different constant temperatures at two sides, and isolated at two other sides. The cavity is filled with a high Prandtl number ferrofluid. The convective force is induced by a magnetic field gradient of a thermally insulated square permanent magnet located at the center of the cavity. The results are presented in the forms of streamlines, isotherms, and Nusselt number for various values of magnetic Rayleigh numbers and permanent magnet size. Two major circulations are generated in the cavity, clockwise flow in the upper half and counterclockwise in the lower half. In addition, strong circulations are observed around the edges of the permanent magnet surface. The strength of the circulations increase monotonically with the magnetic Rayleigh number. The circulations also increase with the permanent magnet size, but eventually, are suppressed for larger sizes. It is found that there is an optimum size for the permanent magnet due to the contrary effects of the increase in magnetic force and the increase in flow resistance by increasing the size. By increasing the magnetic Rayleigh number or isothermal walls temperature ratio, the heat transfer rate increases.

  3. Seismic performance of recycled concrete-filled square steel tube columns

    Science.gov (United States)

    Chen, Zongping; Jing, Chenggui; Xu, Jinjun; Zhang, Xianggang

    2017-01-01

    An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.

  4. Investigation of in-plane moment connections of I-beams to square concrete-filled steel tube columns under gravity loads

    Directory of Open Access Journals (Sweden)

    Abdelrahim K. Dessouki

    2015-04-01

    Full Text Available This paper focuses on experimental and analytical behavior of the ultimate moment of the connections of steel I-beams to square concrete-filled steel tube columns. External stiffeners around the columns are used at the beam flange levels. Five specimens are tested monotonically. The test parameters are the column stiffener dimensions and filling the steel tube column with concrete. Two types of failure modes are observed; beam flange failure and stiffener failure. The experimental results show that the ultimate moment of the connection is increased by increasing stiffener’s dimensions and filling the steel tube column with concrete. ANSYS finite element program is used to simulate the behavior, taking into account both geometric and material nonlinearities. Analytical results that are in fair agreement with the experimental ones are then used to discuss the influence of the main geometric parameters on the connection behavior. The parameters are the stiffener and column dimensions as well as filling the steel tube column with concrete. Different square column cross sections are chosen to cover the three classes of section classifications according to Egyptian code of practice, which are: compact, non compact or slender. The increase in the ultimate moment of the connections is based upon both column cross sections’ compactness and stiffener dimensions while the maximum advantages occur with slender columns.

  5. Integral transform solution of natural convection in a square cavity with volumetric heat generation

    Directory of Open Access Journals (Sweden)

    C. An

    2013-12-01

    Full Text Available The generalized integral transform technique (GITT is employed to obtain a hybrid numerical-analytical solution of natural convection in a cavity with volumetric heat generation. The hybrid nature of this approach allows for the establishment of benchmark results in the solution of non-linear partial differential equation systems, including the coupled set of heat and fluid flow equations that govern the steady natural convection problem under consideration. Through performing the GITT, the resulting transformed ODE system is then numerically solved by making use of the subroutine DBVPFD from the IMSL Library. Therefore, numerical results under user prescribed accuracy are obtained for different values of Rayleigh numbers, and the convergence behavior of the proposed eigenfunction expansions is illustrated. Critical comparisons against solutions produced by ANSYS CFX 12.0 are then conducted, which demonstrate excellent agreement. Several sets of reference results for natural convection with volumetric heat generation in a bi-dimensional square cavity are also provided for future verification of numerical results obtained by other researchers.

  6. DNS of buoyancy-driven flows and Lagrangian particle tracking in a square cavity at high Rayleigh numbers

    International Nuclear Information System (INIS)

    Puragliesi, R.; Dehbi, A.; Leriche, E.; Soldati, A.; Deville, M.O.

    2011-01-01

    Highlights: → 2D study of micro-size particle depletion driven by chaotic natural convective flows in square domains. → Description of velocity and temperature first and second moments with changing in the Rayleigh number. → Strong decoupling between the turbulent kinetic energy and the dissipation rate. → Particle recirculation sustained by the vertical hot boundary layer. → Deposition mostly induced by gravity, thermophoretic and lift forces are negligible. - Abstract: In this work we investigate numerically particle deposition in the buoyancy driven flow of the differentially heated cavity (DHC). We consider two values of the Rayleigh number (Ra = 10 9 , 10 10 ) and three values of the particle diameter (d p = 15, 25, 35 [μm]). We consider the cavity filled with air and particles with the same density of water ρ w = 1000 [kg/m 3 ] (aerosol). We use direct numerical simulations (DNS) for the continuous phase, and we solve transient Navier-Stokes and energy transport equations written in an Eulerian framework, under the Boussinesq approximation, for the viscous incompressible Newtonian fluid with constant Prandtl number (Pr = 0.71). First- and second-order statistics are presented for the continuous phase as well as important quantities like turbulent kinetic energy (TKE) and temperature variance with the associated production and dissipation fields. The TKE production shows different behaviour at the two Rayleigh numbers. The Lagrangian approach has been chosen for the dispersed phase description. The forces taken into account are drag, gravity, buoyancy, lift and thermophoresis. A first incursion in the sedimentation mechanisms is presented. Current results indicate that the largest contribution to particle deposition is caused by gravitational settling, but a strong recirculating zone, which liftoffs and segregates particles, contributes to decrease settling. Deposition takes place mostly at the bottom wall. The influence of lift and thermophoretic

  7. DNS of buoyancy-driven flows and Lagrangian particle tracking in a square cavity at high Rayleigh numbers

    Energy Technology Data Exchange (ETDEWEB)

    Puragliesi, R., E-mail: riccardo.puragliesi@psi.ch [Nuclear Energy and Safety Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Laboratoire d' Ingenierie Numerique, Ecole Polytechnique Federale de Lausanne, Station 9, CH-1015 Lausanne (Switzerland); Dehbi, A., E-mail: abdel.dehbi@psi.ch [Nuclear Energy and Safety Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Leriche, E., E-mail: emmanuel.leriche@univ-st-etienne.fr [Universite de Lyon, F-42023 Saint-Etienne, LMFA-UJM St-Etienne, CNRS UMR 5509 Universite de St-Etienne, 23 rue Docteur Paul Michelon, F-42023 Saint-Etienne (France); Soldati, A., E-mail: soldati@uniud.it [Dipartimento di Energetica e Macchine, Universita di Udine, Via delle Scienze 208, IT-33100 Udine (Italy); Deville, M.O., E-mail: michel.deville@epfl.ch [Laboratoire d' Ingenierie Numerique, Ecole Polytechnique Federale de Lausanne, Station 9, CH-1015 Lausanne (Switzerland)

    2011-10-15

    Highlights: > 2D study of micro-size particle depletion driven by chaotic natural convective flows in square domains. > Description of velocity and temperature first and second moments with changing in the Rayleigh number. > Strong decoupling between the turbulent kinetic energy and the dissipation rate. > Particle recirculation sustained by the vertical hot boundary layer. > Deposition mostly induced by gravity, thermophoretic and lift forces are negligible. - Abstract: In this work we investigate numerically particle deposition in the buoyancy driven flow of the differentially heated cavity (DHC). We consider two values of the Rayleigh number (Ra = 10{sup 9}, 10{sup 10}) and three values of the particle diameter (d{sub p} = 15, 25, 35 [{mu}m]). We consider the cavity filled with air and particles with the same density of water {rho}{sub w} = 1000 [kg/m{sup 3}] (aerosol). We use direct numerical simulations (DNS) for the continuous phase, and we solve transient Navier-Stokes and energy transport equations written in an Eulerian framework, under the Boussinesq approximation, for the viscous incompressible Newtonian fluid with constant Prandtl number (Pr = 0.71). First- and second-order statistics are presented for the continuous phase as well as important quantities like turbulent kinetic energy (TKE) and temperature variance with the associated production and dissipation fields. The TKE production shows different behaviour at the two Rayleigh numbers. The Lagrangian approach has been chosen for the dispersed phase description. The forces taken into account are drag, gravity, buoyancy, lift and thermophoresis. A first incursion in the sedimentation mechanisms is presented. Current results indicate that the largest contribution to particle deposition is caused by gravitational settling, but a strong recirculating zone, which liftoffs and segregates particles, contributes to decrease settling. Deposition takes place mostly at the bottom wall. The influence of lift

  8. Analysis of fluid-solid interaction in MHD natural convection in a square cavity equally partitioned by a vertical flexible membrane

    International Nuclear Information System (INIS)

    Mehryan, S.A.M.; Ghalambaz, Mohammad; Ismael, Muneer A.; Chamkha, Ali J.

    2017-01-01

    This paper investigates numerically the problem of unsteady natural convection inside a square cavity partitioned by a flexible impermeable membrane. The finite element method with the arbitrary Lagrangian-Eulerian (ALE) technique has been used to model the interaction of the fluid and the membrane. The horizontal walls of the cavity are kept adiabatic while the vertical walls are kept isothermal at different temperatures. A uniform magnetic field is applied onto the cavity with different orientations. The cavity has been provided by two eyelets to compensate volume changes due the movement of the flexible membrane. A parametric study is carried out for the pertinent parameters, which are the Rayleigh number (10"5–10"8), Hartmann number (0–200) and the orientation of the magnetic field (0–180°). The change in the Hartmann number affects the shape of the membrane and the heat transfer in the cavity. The angle of the magnetic field orientation also significantly affects the shape of the membrane and the heat transfer in the cavity. - Highlights: • Magnetohydrodynamics heat transfer in a partitioned cavity is studied. • There is a flexible membrane in the cavity. • The membrane is modeled using fluid-solid structure interaction. • A moving grid formulation based on ALE is adopted. • The effect of the magnetic field on the natural convection heat transfer is examined.

  9. Analysis of fluid-solid interaction in MHD natural convection in a square cavity equally partitioned by a vertical flexible membrane

    Energy Technology Data Exchange (ETDEWEB)

    Mehryan, S.A.M., E-mail: a.mansuri1366@gmail.com [Department of Mechanical Engineering, Dezful Branch, Islamic Azad University, Dezful (Iran, Islamic Republic of); Ghalambaz, Mohammad, E-mail: m.ghalambaz@iaud.ac.ir [Department of Mechanical Engineering, Dezful Branch, Islamic Azad University, Dezful (Iran, Islamic Republic of); Ismael, Muneer A., E-mail: muneerismael@yahoo.com [Mechanical Engineering Department, Engineering College, University of Basrah, Basrah (Iraq); Chamkha, Ali J., E-mail: achamkha@pmu.edu.sa [Mechanical Engineering Department, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Prince Sultan Endowment for Energy and Environment, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia)

    2017-02-15

    This paper investigates numerically the problem of unsteady natural convection inside a square cavity partitioned by a flexible impermeable membrane. The finite element method with the arbitrary Lagrangian-Eulerian (ALE) technique has been used to model the interaction of the fluid and the membrane. The horizontal walls of the cavity are kept adiabatic while the vertical walls are kept isothermal at different temperatures. A uniform magnetic field is applied onto the cavity with different orientations. The cavity has been provided by two eyelets to compensate volume changes due the movement of the flexible membrane. A parametric study is carried out for the pertinent parameters, which are the Rayleigh number (10{sup 5}–10{sup 8}), Hartmann number (0–200) and the orientation of the magnetic field (0–180°). The change in the Hartmann number affects the shape of the membrane and the heat transfer in the cavity. The angle of the magnetic field orientation also significantly affects the shape of the membrane and the heat transfer in the cavity. - Highlights: • Magnetohydrodynamics heat transfer in a partitioned cavity is studied. • There is a flexible membrane in the cavity. • The membrane is modeled using fluid-solid structure interaction. • A moving grid formulation based on ALE is adopted. • The effect of the magnetic field on the natural convection heat transfer is examined.

  10. Computational simulation of turbulent natural convection in a volumetrically heated square cavity

    International Nuclear Information System (INIS)

    Vieira, Camila Braga; Su, Jian; Niceno, Bojan

    2012-01-01

    This work aims to analyze the turbulent natural convection in a volumetrically heated fluid with similar characteristics of an oxide layer of a molten core in the lower head of the pressure vessel. The simulations were carried out in a square cavity with isothermal walls, for Rayleigh numbers (Ra) ranging from 10 9 to 10 11 . Different turbulence models based on Reynolds Averaged Navier-Stokes equations were studied, such as the standard k - ε, low-Reynolds-k - ε, and Shear Stress Transport (SST), using the open-source Computational Fluid Dynamics (CFD) code - Open FOAM (Open Field Operation and Manipulation). The results of the three turbulence models were compared versus the results of experimental correlations and other authors’ simulations, and the conclusion was that the most promising model proves to be the SST, due to its accuracy and robustness. (author)

  11. Hybrid lattice Boltzmann finite difference simulation of mixed convection flows in a lid-driven square cavity

    Energy Technology Data Exchange (ETDEWEB)

    Bettaibi, Soufiene, E-mail: Bettaibisoufiene@gmail.com [UR: Rayonnement Thermique, Faculté des Sciences de Tunis, Université de Tunis El Manar, 2092 Tunis (Tunisia); Kuznik, Frédéric [INSA-Lyon, CETHIL, F-69621 Villeurbanne (France); Université de Lyon, CNRS, UMR5008, F-69622 Villeurbanne (France); Sediki, Ezeddine [UR: Rayonnement Thermique, Faculté des Sciences de Tunis, Université de Tunis El Manar, 2092 Tunis (Tunisia)

    2014-06-27

    Highlights: • Mixed convection heat transfer in 2D lid-driven cavity is studied numerically. • Hybrid scheme with multiple relaxation time lattice Boltzmann method is used to obtain the velocity field. • Finite difference method is used to compute the temperature. • Effect of both Richardson and Reynolds numbers for mixed convection is studied. - Abstract: Mixed convection heat transfer in two-dimensional lid-driven rectangular cavity filled with air (Pr=0.71) is studied numerically. A hybrid scheme with multiple relaxation time lattice Boltzmann method (MRT-LBM) is used to obtain the velocity field while the temperature field is deduced from energy balance equation by using the finite difference method (FDM). The main objective of this work is to investigate the model effectiveness for mixed convection flow simulation. Results are presented in terms of streamlines, isotherms and Nusselt numbers. Excellent agreement is obtained between our results and previous works. The different comparisons demonstrate the robustness and the accuracy of our proposed approach.

  12. Solution of the square lid-driven cavity flow of a Bingham plastic using the finite volume method

    OpenAIRE

    Syrakos, Alexandros; Georgiou, Georgios C.; Alexandrou, Andreas N.

    2016-01-01

    We investigate the performance of the finite volume method in solving viscoplastic flows. The creeping square lid-driven cavity flow of a Bingham plastic is chosen as the test case and the constitutive equation is regularised as proposed by Papanastasiou [J. Rheol. 31 (1987) 385-404]. It is shown that the convergence rate of the standard SIMPLE pressure-correction algorithm, which is used to solve the algebraic equation system that is produced by the finite volume discretisation, severely det...

  13. Strain absorbent modules for cavity filling

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    Strain absorbent modules made from weldmesh panels and helical steel binders can be used, together with timber packing, to support the roof and sides of cavities instead of softwood and hardwood nogs. A description of these modules and a series of load tests and underground trials carried out on the modules is given.

  14. Natural oscillations of a gas bubble in a liquid-filled cavity located in a viscoelastic medium

    Science.gov (United States)

    Doinikov, Alexander A.; Marmottant, Philippe

    2018-04-01

    The present study is motivated by cavitation phenomena that occur in the stems of trees. The internal pressure in tree conduits can drop down to significant negative values. This drop gives rise to cavitation bubbles, which undergo high-frequency eigenmodes. The aim of the present study is to determine the parameters of the bubble natural oscillations. To this end, a theory is developed that describes the pulsation of a spherical bubble located at the center of a spherical cavity surrounded by an infinite solid medium. It is assumed that the medium inside the bubble is a gas-vapor mixture, the cavity is filled with a compressible viscous liquid, and the medium surrounding the cavity behaves as a viscoelastic solid. The theoretical solution takes into account the outgoing acoustic wave produced by the bubble pulsation, the incoming wave caused by reflection from the liquid-solid boundary, and the outgoing wave propagating in the solid. A dispersion equation for the calculation of complex wavenumbers of the bubble eigenmodes is derived. Approximate analytical solutions to the dispersion equation are found. Numerical simulations are performed to reveal the effect of different physical parameters on the resonance frequency and the attenuation coefficient of the bubble oscillations.

  15. Effect of bulk-fill base material on fracture strength of root-filled teeth restored with laminate resin composite restorations.

    Science.gov (United States)

    Taha, N A; Maghaireh, G A; Ghannam, A S; Palamara, J E

    2017-08-01

    To evaluate the effect of using a bulk-fill flowable base material on fracture strength and fracture patterns of root-filled maxillary premolars with MOD preparations restored with laminate restorations. Fifty extracted maxillary premolars were selected for the study. Standardized MOD cavities with endodontic treatment were prepared for all teeth, except for intact control. The teeth were divided randomly into five groups (n=10); (Group 1) sound teeth, (Group 2) unrestored teeth; (Group 3) MOD cavities with Vitrebond base and resin-based composite (Ceram. X One Universal); (Group 4) MOD cavities with 2mm GIC base (Fuji IX GP) and resin-based composite (Ceram. X One Universal) open laminate, (Group 5) MOD cavities were restored with 4mm of bulk-fill flowable base material (SDR) and resin-based composite (Ceram. X One Universal). All teeth were thermocycled and subjected to a 45° ramped oblique load in a universal testing machine. Fracture load and fracture patterns were recorded. Data were analyzed using one-way ANOVA and Dunnett's T3 test. Restoration in general increased the fracture strength compared to unrestored teeth. The fracture strength of group 5 (bulk-fill) was significantly higher than the fracture strength of the GIC laminate groups and not significantly different from the intact teeth (355±112N, P=0.118). The type of failure was unfavorable for most of the groups, with the majority being mixed failures. The use of a bulk-fill flowable base material significantly increased the fracture strength of extracted root-filled teeth with MOD cavities; however it did not improve fracture patterns to more favorable ones. Investigating restorative techniques that may improve the longevity of root-filled premolar teeth restored with direct resin restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Cavities produced by underground nuclear explosions

    International Nuclear Information System (INIS)

    Butkovich, T.R.

    1976-01-01

    This investigation studied the displacement of rock that formerly occupied cavities produced by underground nuclear explosions. There are three possible explanations for this displacement: the volume could be displaced to the free surface; it could occupy previously air-filled pores removed from the surrounding rock through compaction; or it could be accounted for by persisting compressive stresses induced by the outgoing shock wave. The analysis shows it unlikely that stored residual elastic stresses account for large fractions of cavity volumes. There is limited experimental evidence that free surface displacement accounts for a significant portion of this volume. Whenever the explosion mediums contain air-filled pores, the compaction of these pores most likely accounts for all the volume. Calculations show that 4 percent air-filled porosity can account for all the cavity volume within about 4 cavity radii and that even 1 percent can account for a significant fraction of the volume

  17. Free-Energy Barrier of Filling a Spherical Cavity in the Presence of Line Tension: Implication to the Energy Barrier between the Cassie and Wenzel States on a Superhydrophobic Surface with Spherical Cavities.

    Science.gov (United States)

    Iwamatsu, Masao

    2016-09-20

    The free-energy barrier of filling a spherical cavity having an inner wall of various wettabilities is studied. The morphology and free energy of a lens-shaped droplet are determined from the minimum of the free energy. The effect of line tension on the free energy is also studied. Then, the equilibrium contact angle of the droplet is determined from the generalized Young's equation. By increasing the droplet volume within the spherical cavity, the droplet morphology changes from spherical with an equilibrium contact angle of 180° to a lens with a convex meniscus, where the morphological complete drying transition occurs. By further increasing the droplet volume, the meniscus changes from convex to concave. Then, the lens-shaped droplet with concave meniscus spreads over the whole inner wall, resulting in an equilibrium contact angle of 0° to leave a spherical bubble, where the morphological complete wetting transition occurs. Finally, the whole cavity is filled with liquid. The free energy shows a barrier from complete drying to complete wetting as a function of droplet volume, which corresponds to the energy barrier between the Cassie and Wenzel states of the superhydrophobic surface with spherical cavities. The free-energy maximum occurs when the meniscus of the droplet becomes flat, and it is given by an analytic formula. The effect of line tension is expressed by the scaled line tension, and this effect is largest at the free-energy maximum. The positive line tension increases the free-energy maximum, which thus increases the stability of the Cassie superhydrophobic state, whereas the negative line tension destabilizes the superhydrophobic state.

  18. Enhanced heat transfer in partially open square cavities with thin fin by using electric field

    International Nuclear Information System (INIS)

    Kasayapanand, N.; Kiatsiriroat, T.

    2009-01-01

    Numerical modeling of the electric field effect on the natural convection in the partially open square cavities with thin fin attached is investigated. The interactions among electric, flow, and temperature fields are analyzed by using a computational fluid dynamics technique. It is found that the flow and heat transfer enhancements are a decreasing function of the Rayleigh number. Moreover, the volume flow rate and heat transfer coefficient are substantially improved by electrohydrodynamic especially at low aperture size, high aperture position, and high inclined angle. Surprisingly, the maximum convective heat transfer is obtained at the minimum electrical energy consumption by placing electrodes at a suitable position. The optimum electrode arrangements for both single fin and multiple fins are also achieved

  19. Wake-field studies on photonic band gap accelerator cavities

    International Nuclear Information System (INIS)

    Li, D.; Kroll, N.; Stanford Linear Accelerator Center, M/S 26, P.O. Box 4349, Stanford, California; Smith, D.R.; Schultz, S.

    1997-01-01

    We have studied the wake-field of several metal Photonic Band Gap (PBG) cavities which consist of either a square or a hexagonal array of metal cylinders, bounded on top and bottom by conducting or superconducting sheets, surrounded by placing microwave absorber at the periphery or by replacing outer rows of metal cylinders with lossy dielectric ones, or by metallic walls. A removed cylinder from the center of the array constitutes a site defect where a localized electromagnetic mode can occur. While both monopole and dipole wake-fields have been studied, we confine our attention here mainly to the dipole case. The dipole wake-field is produced by modes in the propagation bands which tend to fill the entire cavity more or less uniformly and are thus easy to damp selectively. MAFIA time domain simulation of the transverse wake-field has been compared with that of a cylindrical pill-box comparison cavity. Even without damping the wake-field of the metal PBG cavity is substantially smaller than that of the pill-box cavity and may be further reduced by increasing the size of the lattice. By introducing lossy material at the periphery we have been able to produce Q factors for the dipole modes in the 40 to 120 range without significantly degrading the accelerating mode. copyright 1997 American Institute of Physics

  20. A free-surface lattice Boltzmann method for modelling the filling of expanding cavities by Bingham fluids.

    Science.gov (United States)

    Ginzburg, Irina; Steiner, Konrad

    2002-03-15

    The filling process of viscoplastic metal alloys and plastics in expanding cavities is modelled using the lattice Boltzmann method in two and three dimensions. These models combine the regularized Bingham model for viscoplastic fluids with a free-interface algorithm. The latter is based on a modified immiscible lattice Boltzmann model in which one species is the fluid and the other one is considered to be a vacuum. The boundary conditions at the curved liquid-vacuum interface are met without any geometrical front reconstruction from a first-order Chapman-Enskog expansion. The numerical results obtained with these models are found in good agreement with available theoretical and numerical analysis.

  1. Characteristics of low polymerization shrinkage flowable resin composites in newly-developed cavity base materials for bulk filling technique.

    Science.gov (United States)

    Nitta, Keiko; Nomoto, Rie; Tsubota, Yuji; Tsuchikawa, Masuji; Hayakawa, Tohru

    2017-11-29

    The purpose of this study was to evaluate polymerization shrinkage and other physical properties of newly-developed cavity base materials for bulk filling technique, with the brand name BULK BASE (BBS). Polymerization shrinkage was measured according to ISO/FDIS 17304. BBS showed the significantly lowest polymerization shrinkage and significantly higher depth of cure than conventional flowable resin composites (p<0.05). The Knoop hardness, flexural strength and elastic modulus of that were significantly lower than conventional flowable resin composites (p<0.05). BBS had the significantly greatest filler content (p<0.05). SEM images of the surface showed failure of fillers. The lowest polymerization shrinkage was due to the incorporation of a new type of low shrinkage monomer, which has urethane moieties. There were no clear correlations between inorganic filler contents and polymerization shrinkage, flexural strength and elastic modulus. In conclusion, the low polymerization shrinkage of BBS will be useful for cavity treatment in dental clinics.

  2. Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation

    Directory of Open Access Journals (Sweden)

    Chaoping Hou

    2018-06-01

    Full Text Available Wall insulation performance is an important factor affecting building energy consumption and indoor comfortable level. This study proposes that the insulation materials are filled into the cavities of the sintered hollow brick to replace the single insulation layer. The physical models of typical walls were built by the hollow bricks filled with expanding polystyrene board (EPS in cavities and wall thermal performance is numerically analyzed by the Finite Volume Method under air-conditioning intermittent operation, which conforms to the actual operation rules of air-conditioning. Results show that filling EPS in cavities is beneficial to improve the thermal performance of the bricks, and the larger the EPS filling ratio, the higher the thermal performance improvement. The EPS filling ratio increase has the higher sensitivity on inner surface heat flow under the low EPS filling ratio, and filling EPS in the external cavities is optimum with the decrement rate 5.92% higher than filling EPS in internal cavities for the EPS filling ratio of 20%, while filling EPS in internal and external cavities simultaneously is optimum with decrement rate 2.45%–6.87% higher than that with filling EPS in the internal cavities for the EPS filling ratio of 40%–80%. Keywords: Insulation filling ratio, Insulation filling location, Thermal performance, Sintered hollow bricks

  3. Axial Compression Properties Nonlinear Analysis on Square Double Skin Steel Stub Short Columns Filled with Recycled Concrete

    Directory of Open Access Journals (Sweden)

    Song Bing

    2016-01-01

    Full Text Available Taking the mixing amount of diatomite calcined and vitrified micro bubbles(VMB as the main changing parameters, experiment studies the properties of the vitrified micro bubbles recycled concrete blocks; then this paper adopts the finite element software ANSYS to analyze the square double skin steel stub short columns filled with recycled concrete under axial compression. According to the vertical stress distribution, strain and bearing capacity of the steel tube and core concrete, we make a contrastive axial compression properties analysis on the different hollow ratio χ(0,0.35and the VMB content(0%,100%,130% of square double skin steel stub short columns filled with recycled concrete. The result shows that: Compressive strength of VMB recycled concrete increases with the increase of diatomite calcined content, when mixing amount of diatomite calcined is 3%,the compressive strength of 130% VMB content test specimen can reach 32.45 MPa;Because of the inner circular steel tube is setted which strengthening component buckling capacity and improving the ductility of the component, stress distribution of hollow components is more balance than solid components, and their axial displacements decrease by 5.6% compared with the solid components when they reach ultimate bearing capacity; When the hollow ratio is same, ultimate bearing capacity of 130% VMB content test specimen compared with the content is 0% only reduces by about 3.5%; When the VMB content is same, ultimate bearing capacity of hollow components compared with solid components increases by about 2.5%, which reducing weight as well as improving the anti-seismic performance.

  4. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  5. Numerical simulations of the effect of an isotropic heat field on the entropy generation due to natural convection in a square cavity

    International Nuclear Information System (INIS)

    El-Maghlany, Wael M.; Saqr, Khalid M.; Teamah, Mohamed A.

    2014-01-01

    Highlights: • Entropy generation in laminar natural convection in square cavity numerically studied. • The cavity subjected to an isotropic heat field with different intensities. • Study ranges 10 3 ⩽ Ra ⩽ 10 5 , 0 ⩽ ϕ ⩽ 10 and Pr = 0.7. • Entropy generation drastically affected by the superposition of an isotropic heat field. • CFD based empirical were derived for entropy generation as a function of Ra and φ. - Abstract: Entropy generation associated with laminar natural convection in an infinite square cavity, subjected to an isotropic heat field with different intensities; was numerically investigated for different values of Rayleigh number. The numerical work was carried out using, an in-house CFD code written in FORTRAN, which discretizes non-dimensional forms of the governing equations using the finite volume method and solves the resulting system of equations using Gauss-Seidal method utilizing a TDMA algorithm. Proper code validation was undertaken in order to establish the entropy generation calculations. It was found that the increase in the isotropic heat field intensity resulted in a corresponding exponential increase of the entropy augmentation number, and promoted high values of Bejan number within the flow. The entropy generation due to heat transfer was approximately one order of magnitude higher than the entropy generation due to fluid friction. The spatial uniformity of the Bejan number was more sensitive to the change in Rayleigh number than to the heat field intensity. The thermodynamic penalty of the isotropic heat field is shown by means of global integrals of the entropy source terms over the entire flow domain

  6. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...... Class II, 4 SDR-CeramX mono+ and 6 CeramXmono+-only restorations. The main reasons for failurewere tooth fracture (6) and secondary caries (4). The annual failure rate (AFR) for all restorations (Class I and II) was for the bulk-filled-1.1% and for the resin composite-only restorations 1...

  7. Investigation of Mild Steel Thin-Wall Tubes in Unfilled and Foam-Filled Triangle, Square, and Hexagonal Cross Sections Under Compression Load

    Science.gov (United States)

    Rajak, Dipen Kumar; Kumaraswamidhas, L. A.; Das, S.

    2018-02-01

    This study has examined proposed structures with mild steel-reinforced LM30 aluminum (Al) alloy having diversely unfilled and 10 wt.% SiCp composite foam-filled tubes for improving axial compression performance. This class of material has novel physical, mechanical, and electrical properties along with low density. In the present experiment, Al alloy foams were prepared by the melt route technique using metal hydride powder as a foaming agent. Crash energy phenomena for diverse unfilled and foam-filled in mild steel thin-wall tubes (triangular, square and hexagonal) were studied as well. Compression deformation investigation was conducted at strain rates of 0.001-0.1/s for evaluating specific energy absorption (SEA) under axial loading conditions. The results were examined to measure plateau stress, maximum densification strain, and deformation mechanism of the materials. Specific energy absorption and total energy absorption capacities of the unfilled and filled sections were determined from the compressive stress-strain curves, which were then compared with each other.

  8. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials

    DEFF Research Database (Denmark)

    Moorthy, A; Hogg, C H; Dowling, A H

    2012-01-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases.......To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases....

  9. Anatomical robust optimization to account for nasal cavity filling variation during intensity-modulated proton therapy: a comparison with conventional and adaptive planning strategies

    Science.gov (United States)

    van de Water, Steven; Albertini, Francesca; Weber, Damien C.; Heijmen, Ben J. M.; Hoogeman, Mischa S.; Lomax, Antony J.

    2018-01-01

    The aim of this study is to develop an anatomical robust optimization method for intensity-modulated proton therapy (IMPT) that accounts for interfraction variations in nasal cavity filling, and to compare it with conventional single-field uniform dose (SFUD) optimization and online plan adaptation. We included CT data of five patients with tumors in the sinonasal region. Using the planning CT, we generated for each patient 25 ‘synthetic’ CTs with varying nasal cavity filling. The robust optimization method available in our treatment planning system ‘Erasmus-iCycle’ was extended to also account for anatomical uncertainties by including (synthetic) CTs with varying patient anatomy as error scenarios in the inverse optimization. For each patient, we generated treatment plans using anatomical robust optimization and, for benchmarking, using SFUD optimization and online plan adaptation. Clinical target volume (CTV) and organ-at-risk (OAR) doses were assessed by recalculating the treatment plans on the synthetic CTs, evaluating dose distributions individually and accumulated over an entire fractionated 50 GyRBE treatment, assuming each synthetic CT to correspond to a 2 GyRBE fraction. Treatment plans were also evaluated using actual repeat CTs. Anatomical robust optimization resulted in adequate CTV doses (V95%  ⩾  98% and V107%  ⩽  2%) if at least three synthetic CTs were included in addition to the planning CT. These CTV requirements were also fulfilled for online plan adaptation, but not for the SFUD approach, even when applying a margin of 5 mm. Compared with anatomical robust optimization, OAR dose parameters for the accumulated dose distributions were on average 5.9 GyRBE (20%) higher when using SFUD optimization and on average 3.6 GyRBE (18%) lower for online plan adaptation. In conclusion, anatomical robust optimization effectively accounted for changes in nasal cavity filling during IMPT, providing substantially improved CTV and

  10. Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall

    Directory of Open Access Journals (Sweden)

    Hoon-Sang Chang

    2013-07-01

    Full Text Available OBJECTIVE: The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall. MATERIAL AND METHODS: Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA. RESULTS: The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall. CONCLUSION: In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity.

  11. Predictions of laminar natural convection in heated cavities

    International Nuclear Information System (INIS)

    Winters, K.H.

    1982-06-01

    Several examples of laminar, natural convection in heated cavities are discussed with illustrative calculations. These include convection in a square cavity at high Rayleigh number; in a narrow cavity at moderate aspect ratio; in a rectangular cavity heated from below; in a trapezoidal cavity, and in a rectangular cavity containing a conducting obstruction. The steady equations for the velocity, pressure and temperature are solved in the Boussinesq approximation, using a standard Galerkin formulation of the finite-element method. (author)

  12. Onset of Soret-driven convection of binary fluid in square cavity heated from above at different gravity levels

    Science.gov (United States)

    Lyubimova, Tatyana; Zubova, Nadezhda

    The instability of incompressible viscous binary fluid with the Soret effect in square cavity heated from above is studied for different gravity levels. The no slip and zero mass flux conditions are imposed on all the boundaries. The horizontal boundaries are perfectly conductive, they are maintained at constant different temperatures and vertical boundaries are adiabatic. The calculations are performed for water - isopropanol mixture 90:10. Initial conditions correspond to the motionless state with uniform distribution of components and uniform temperature gradient directed upward. For binary fluid under consideration the separation parameter is negative therefore the Soret effect leads to the accumulation of heavy component in the upper part of cavity, moreover, the rate of accumulation is independent of the gravity level. The linear stability of the unsteady motionless state is studied numerically by solving linearized equations for small perturbations. To determine the time t* for the onset of instability, the criterion suggested in [1] is used. The dependence of t* on the gravity level is obtained. The work was done under financial support of Government of Perm Region, Russia (Contract C-26/212). 1. Shliomis M.I., Souhar M. Europhysics Letters. 2000. Vol. 49 (1), pp. 55-61.

  13. Microtensile bond strength of bulk-fill restorative composites to dentin.

    Science.gov (United States)

    Mandava, Jyothi; Vegesna, Divya-Prasanna; Ravi, Ravichandra; Boddeda, Mohan-Rao; Uppalapati, Lakshman-Varma; Ghazanfaruddin, M D

    2017-08-01

    To facilitate the easier placement of direct resin composite in deeper cavities, bulk fill composites have been introduced. The Mechanical stability of fillings in stress bearing areas restored with bulk-fill resin composites is still open to question, since long term clinical studies are not available so far. Thus, the objective of the study was to evaluate and compare the microtensile bond strength of three bulk-fill restorative composites with a nanohybrid composite. Class I cavities were prepared on sixty extracted mandibular molars. Teeth were divided into 4 groups (n= 15 each) and in group I, the prepared cavities were restored with nanohybrid (Filtek Z250 XT) restorative composite in an incremental manner. In group II, III and IV, the bulk-fill composites (Filtek, Tetric EvoCeram, X-tra fil bulk-fill restoratives) were placed as a 4 mm single increment and light cured. The restored teeth were subjected to thermocycling and bond strength testing was done using instron testing machine. The mode of failure was assessed by scanning electron microscope (SEM). The bond strength values obtained in megapascals (MPa) were subjected to statistical analysis, using SPSS/PC version 20 software.One-way ANOVA was used for groupwise comparison of the bond strength. Tukey's Post Hoc test was used for pairwise comparisons among the groups. The highest mean bond strength was achieved with Filtek bulk-fill restorative showing statistically significant difference with Tetric EvoCeram bulk-fill ( p composites. Adhesive failures are mostly observed with X-tra fil bulk fill composites, whereas mixed failures are more common with other bulk fill composites. Bulk-fill composites exhibited adequate bond strength to dentin and can be considered as restorative material of choice in posterior stress bearing areas. Key words: Bond strength, Bulk-fill restoratives, Configuration factor, Polymerization shrinkage.

  14. SPS RF Accelerating Cavity

    CERN Multimedia

    1979-01-01

    This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X

  15. Wave propagation in plasma-filled wave-guide

    International Nuclear Information System (INIS)

    Leprince, Philippe

    1966-01-01

    This research thesis reports the study of wave propagation along a plasma column without external magnetic field. The author first present and comment various theoretical results, and dispersion curves plotted for the main modes (particularly, the bipolar mode). He tries to define fundamental magnitudes which characterise a plasma-filled wave-guide. He reports the comparison of some experimental results with the previous theoretical results. Based on the study of the bipolar mode, the author develops a method of measurement of plasma column density. In the last part, the author reports the study of the resonance of a plasma-containing cavity. Several resonances are highlighted and new dispersion curves are plotted by using a varying length cavity. He also addresses the coupling of plasma modes with guide modes, and thus indicates the shape of Brillouin diagrams for a plasma-filled wave-guide. Moreover, some phenomena highlighted during plasma column density measurements by using the cavity method could then be explained [fr

  16. Superconducting cavity driving with FPGA controller

    International Nuclear Information System (INIS)

    Czarski, Tomasz; Koprek, Waldemar; Pozniak, Krzysztof T.; Romaniuk, Ryszard S.; Simrock, Stefan; Brandt, Alexander; Chase, Brian; Carcagno, Ruben; Cancelo, Gustavo; Koeth, Timothy W.

    2006-01-01

    A digital control of superconducting cavities for a linear accelerator is presented. FPGA-based controller, supported by Matlab system, was applied. Electrical model of a resonator was used for design of a control system. Calibration of the signal path is considered. Identification of cavity parameters has been carried out for adaptive control algorithm. Feed-forward and feedback modes were applied in operating the cavities. Required performance has been achieved; i.e. driving on resonance during filling and field stabilization during flattop time, while keeping reasonable level of the power consumption. Representative results of the experiments are presented for different levels of the cavity field gradient

  17. Pressurized rf cavities in ionizing beams

    Directory of Open Access Journals (Sweden)

    B. Freemire

    2016-06-01

    Full Text Available A muon collider or Higgs factory requires significant reduction of the six dimensional emittance of the beam prior to acceleration. One method to accomplish this involves building a cooling channel using high pressure gas filled radio frequency cavities. The performance of such a cavity when subjected to an intense particle beam must be investigated before this technology can be validated. To this end, a high pressure gas filled radio frequency (rf test cell was built and placed in a 400 MeV beam line from the Fermilab linac to study the plasma evolution and its effect on the cavity. Hydrogen, deuterium, helium and nitrogen gases were studied. Additionally, sulfur hexafluoride and dry air were used as dopants to aid in the removal of plasma electrons. Measurements were made using a variety of beam intensities, gas pressures, dopant concentrations, and cavity rf electric fields, both with and without a 3 T external solenoidal magnetic field. Energy dissipation per electron-ion pair, electron-ion recombination rates, ion-ion recombination rates, and electron attachment times to SF_{6} and O_{2} were measured.

  18. Free convection performance of circular cavities having two active curved vertical sides and two inactive curved horizontal sides

    International Nuclear Information System (INIS)

    Ridouane, El Hassan; Campo, Antonio

    2006-01-01

    A detailed review of the archival reveals that the heat transfer and fluid flow characteristics of circular cavities have not been investigated so far and of course their physical features are not understood. A prominent application of these cavities arises in the miniaturized packaging of electronic components that are subject to strict constraints. This paper addresses primarily steady-state laminar natural convection of air in a circular cavity of diameter H inscribed in a square cavity of side H where the corresponding sides are in contact at four points. A third cavity, an arc-square cavity whose shape lies between the square and circular cavity shapes is included in the analysis. The finite volume method is used to perform the numerical simulations. The methodology takes into account the second-order-accurate QUICK scheme for the discretization of the convective term, whereas the pressure-velocity coupling is handled with the SIMPLE scheme. Since the air is not assumed a Boussinesq gas, it was decided to take all thermophysical properties as temperature-dependent. In the end, it has been demonstrated that the circular cavity possesses a superior balance between heat transfer enhancement and size in cross-section area in comparison with the standard square cavity. The side of the square cavity is similar to the diameter of the circular cavity

  19. Influence of the variable thermophysical properties on the turbulent buoyancy-driven airflow inside open square cavities

    Science.gov (United States)

    Zamora, Blas; Kaiser, Antonio S.

    2012-01-01

    The effects of the air variable properties (density, viscosity and thermal conductivity) on the buoyancy-driven flows established in open square cavities are investigated, as well as the influence of the stated boundary conditions at open edges and the employed differencing scheme. Two-dimensional, laminar, transitional and turbulent simulations are obtained, considering both uniform wall temperature and uniform heat flux heating conditions. In transitional and turbulent cases, the low-Reynolds k - ω turbulence model is employed. The average Nusselt number and the dimensionless mass-flow rate have been obtained for a wide and not yet covered range of the Rayleigh number varying from 103 to 1016. The results obtained taking into account variable properties effects are compared with those calculated assuming constant properties and the Boussinesq approximation. For uniform heat flux heating, a correlation for the critical heating parameter above which the burnout phenomenon can be obtained is presented, not reported in previous works. The effects of variable properties on the flow patterns are analyzed.

  20. Lattice Boltzmann simulation for temperature-sensitive magnetic fluids in a porous square cavity

    International Nuclear Information System (INIS)

    Jin Licong; Zhang Xinrong; Niu Xiaodong

    2012-01-01

    A lattice Boltzmann method is developed to simulate temperature-sensitive magnetic fluids in a porous cavity. In the simulation, the magnetic force, efficient gravity, viscous loss term and geometric loss term in porous medium are imported to the momentum equation. To test the reliability of the method, a validation with water in porous cavity is carried out. Good agreements with the previous results verify that the present lattice Boltzmann method is promising for simulation of magnetic fluids in porous medium. In this study, we investigate the change of magnetization with external magnetic field, and we present numerical results for the streamlines, isotherms, and magnetization at vertical or horizontal mid-profiles for different values of Ram. In addition, Nusselt numbers changing with magnetic Rayleigh numbers are also investigated. - Highlights: → Developed a lattice Boltzmann method for magnetic nano-fluids in porous cavity. → Clarified flow and heat transfer for different values of (magnetic) Rayleigh numbers. → Heat transfer enhancement for magnetic fluid in porous cavity.

  1. Resolving the stratification discrepancy of turbulent natural convection in differentially heated air-filled cavities. Part III: A full convection–conduction–surface radiation coupling

    International Nuclear Information System (INIS)

    Xin, Shihe; Salat, Jacques; Joubert, Patrice; Sergent, Anne; Penot, François; Quéré, Patrick Le

    2013-01-01

    Highlights: ► Turbulent natural convection is studied numerically and experimentally. ► DNS of full conduction–convection–radiation coupling is performed. ► Spectral methods are combined with domain decomposition. ► Considering surface radiation improves strongly numerical results. ► Surface radiation is responsible for the weak stratification. -- Abstract: The present study concerns an air-filled differentially heated cavity of 1 m × 0.32 m × 1 m (width × depth × height) subject to a temperature difference of 15 K and is motivated by the need to understand the persistent discrepancy observed between numerical and experimental results on thermal stratification in the cavity core. An improved experiment with enhanced metrology was set up and experimental data have been obtained along with the characteristics of the surfaces and materials used. Experimental temperature distributions on the passive walls have been introduced in numerical simulations in order to provide a faithful prediction of experimental data. By means of DNS using spectral methods, heat conduction in the insulating material is first coupled with natural convection in the cavity. As heat conduction influences only the temperature distribution on the top and bottom surfaces and in the near wall regions, surface radiation is added to the coupling of natural convection with heat conduction. The temperature distribution in the cavity is strongly affected by the polycarbonate front and rear walls of the cavity, which are almost black surfaces for low temperature radiation, and also other low emissivity walls. The thermal stratification is considerably weakened by surface radiation. Good agreement between numerical simulations and experiments is observed on both time-averaged fields and turbulent statistics. Treating the full conduction–convection–radiation coupling allowed to confirm that experimental wall temperatures resulted from the coupled phenomena and this is another way to

  2. Chaos and Beyond in a Water Filled Ultrasonic Resonance System

    Science.gov (United States)

    Lazlo, Adler; Yost, W.; Cantrell, John H.

    2013-01-01

    Finite amplitude ultrasonic wave resonances in a one-dimensional liquid-filled cavity, formed by a narrow band transducer and a plane reflector, are reported. The resonances are observed to include not only the expected harmonic and subharmonic signals (1,2) but chaotic signals as well. The generation mechanism requires attaining a threshold value of the driving amplitude that the liquid-filled cavity system becomes sufficiently nonlinear in response. The nonlinear features of the system were recently investigated via the construction of an ultrasonic interferometer having optical precision. The transducers were compressional, undamped quartz and lithium niobate crystals having the frequency range 1-10 MHz, driven by a high power amplifier. Both an optical diffraction system to characterize the diffraction pattern of laser light normally incident to the cavity and a receiving transducer attached to an aligned reflector with lapped flat and parallel surfaces were used to assess the generated resonance response in the cavity. At least 5 regions of excitation are identified.

  3. Analytical & Experimental Study of Radio Frequency Cavity Beam Profile Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, Mario D. [Fermilab; Yonehara, Katsuya [Fermilab

    2017-10-22

    The purpose of this analytical and experimental study is multifold: 1) To explore a new, radiation-robust, hadron beam profile monitor for intense neutrino beam applications; 2) To test, demonstrate, and develop a novel gas-filled Radio-Frequency (RF) cavity to use in this monitoring system. Within this context, the first section of the study analyzes the beam distribution across the hadron monitor as well as the ion-production rate inside the RF cavity. Furthermore a more effecient pixel configuration across the hadron monitor is proposed to provide higher sensitivity to changes in beam displacement. Finally, the results of a benchtop test of the tunable quality factor RF cavity will be presented. The proposed hadron monitor configuration consists of a circular array of RF cavities located at a radial distance of 7cm { corresponding to the standard deviation of the beam due to scatering { and a gas-filled RF cavity with a quality factor in the range 400 - 800.

  4. Influence of artificial cavity age on red-cockaded woodpecker translocation success

    Science.gov (United States)

    Daniel Saenz; Richard R. Schaefer; Richard N. Conner; D. Craig Rudolph; Dawn K. Carrie; M. Stephen Best

    2004-01-01

    Red-cockaded woodpecker (Picoides borealis) translocations have been used to bolster woodpecker populations and to fill breeding vacancies. Artificial, insert cavities have been used to offset cavity shortages in woodpecker clusters and are the primary cavity type used in recruitment clusters in Texas and Arkansas, but inserts may lose their...

  5. Bulk fill restoratives: to cap or not to cap--that is the question?

    Science.gov (United States)

    Tomaszewska, Iwona M; Kearns, Jennifer O; Ilie, Nicoleta; Fleming, Garry J P

    2015-03-01

    To assess the cuspal deflection and cervical microleakage scores of standardised large mesio-occlusal-distal (MOD) cavities filled with different restoration protocols: (1) conventional resin restoratives, (2) bulk fill flowable base materials 'capped' with a conventional dimethacrylate resin-based composite (RBC) or (3) bulk fill resin restorative materials. Standardised MOD cavities were prepared in sixty-four sound maxillary premolar teeth and randomly allocated to eight groups. Restorations were placed in conjunction with a universal bonding system and resin restorative materials were irradiated with a quartz-tungsten-halogen light-curing-unit. Restoration protocol (eight oblique increments of conventional resin restorative, bulk fill flowable base and two occlusal 'capping' RBC increments (three increments in total) or bulk fill resin restorative (two increments)) was the dependent variable. A twin channel deflection measuring gauge measured the buccal and palatal cuspal deflections. Teeth were thermally fatigued, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. Post hoc Tukey's tests highlighted significant differences in the mean total cuspal deflection values between resin restoratives (p fill flowable base materials with occlusal 'capping' RBC increments (restoration protocol 2) compared with bulk fill resin restoratives (restoration protocol 3). Not all bulk fill flowable materials or bulk fill resin restoratives behave in a similar fashion when used to restore standardised MOD cavities in maxillary premolar teeth and material selection is vital in the absence of clinical data. Poorly performing bulk fill flowable materials or bulk fill restoratives can be identified using the cuspal deflection and cervical microleakage protocol which could save the complications encountered clinically when restoring Class II restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Factors affecting marginal integrity of class II bulk-fill composite resin restorations

    Science.gov (United States)

    Savadi Oskoee, Siavash; Bahari, Mahmoud; Jafari Navimipour, Elmira; Ajami, Amir Ahmad; Ghiasvand, Negar; Savadi Oskoee, Ayda

    2017-01-01

    Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (Pcomposite resin type and margin location (Pcomposite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins. PMID:28748051

  7. Optimization of the geometrical stability in square ring laser gyroscopes

    International Nuclear Information System (INIS)

    Santagata, R; Beghi, A; Cuccato, D; Belfi, J; Beverini, N; Virgilio, A Di; Ortolan, A; Porzio, A; Solimeno, S

    2015-01-01

    Ultra-sensitive ring laser gyroscopes are regarded as potential detectors of the general relativistic frame-dragging effect due to the rotation of the Earth. Our project for this goal is called GINGER (gyroscopes in general relativity), and consists of a ground-based triaxial array of ring lasers aimed at measuring the rotation rate of the Earth with an accuracy of 10 −14 rad s −1 . Such an ambitious goal is now within reach, as large-area ring lasers are very close to the required sensitivity and stability. However, demanding constraints on the geometrical stability of the optical path of the laser inside the ring cavity are required. Thus, we have begun a detailed study of the geometry of an optical cavity in order to find a control strategy for its geometry that could meet the specifications of the GINGER project. As the cavity perimeter has a stationary point for the square configuration, we identify a set of transformations on the mirror positions that allows us to adjust the laser beam steering to the shape of a square. We show that the geometrical stability of a square cavity strongly increases by implementing a suitable system to measure the mirror distances, and that the geometry stabilization can be achieved by measuring the absolute lengths of the two diagonals and the perimeter of the ring. (paper)

  8. Effect of finite cavity width on flow oscillation in a low-Mach-number cavity flow

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ke; Naguib, Ahmed M. [Michigan State University, East Lansing, MI (United States)

    2011-11-15

    The current study is focused on examining the effect of the cavity width and side walls on the self-sustained oscillation in a low Mach number cavity flow with a turbulent boundary layer at separation. An axisymmetric cavity geometry is employed in order to provide a reference condition that is free from any side-wall influence, which is not possible to obtain with a rectangular cavity. The cavity could then be partially filled to form finite-width geometry. The unsteady surface pressure is measured using microphone arrays that are deployed on the cavity floor along the streamwise direction and on the downstream wall along the azimuthal direction. In addition, velocity measurements using two-component Laser Doppler Anemometer are performed simultaneously with the array measurements in different azimuthal planes. The compiled data sets are used to investigate the evolution of the coherent structures generating the pressure oscillation in the cavity using linear stochastic estimation of the velocity field based on the wall-pressure signature on the cavity end wall. The results lead to the discovery of pronounced harmonic pressure oscillations near the cavity's side walls. These oscillations, which are absent in the axisymmetric cavity, are linked to the establishment of a secondary mean streamwise circulating flow pattern near the side walls and the interaction of this secondary flow with the shear layer above the cavity. (orig.)

  9. Eigenmodes of a microwave cavity partially filled with an anisotropic hot plasma

    International Nuclear Information System (INIS)

    Shoucri, M.M.; Gagne, R.R.J.

    1978-01-01

    The eigenmodes of a microwave cavity, which contains a uniform hot plasma with anisotropic temperature, are determined using the linearized fluid equations together with Maxwell's equations. Conditions are discussed under which hot plasma mode and the cold plasma mode are decoupled. The frequency shift of the microwave cavity is calculated and the theoretical results are shown to be in very good qualitative agreement with published experimental results obtained for the TM 010 mode. (author)

  10. Superconducting Radio-Frequency Cavities for Low-Beta Particle Accelerators

    Science.gov (United States)

    Kelly, Michael

    2012-01-01

    High-power proton and ion linac projects based on superconducting accelerating cavities are driving a worldwide effort to develop and build superconducting cavities for beta < 1. Laboratories and institutions building quarter-wave, halfwave and single- or multi-spoke cavities continue to advance the state of the art for this class of cavities, and the common notion that low-beta SRF cavities fill a need in niche applications and have low performance is clearly no longer valid. This article reviews recent developments and results for SC cavity performance for cavities with beta up to approximately 0.5. The considerable ongoing effort on reduced beta elliptical cell cavities is not discussed. An overview of associated subsystems required to operate low-beta cavities, including rf power couplers and fast and slow tuners, is presented.

  11. Nasal cavity of the farmed african catfish Clarias gariepinus ...

    African Journals Online (AJOL)

    The nasal cavity microanatomy of farmed fingerlings of African catfish, Clarias gariepunus was investigated to fill existing knowledge gap on its histology from available literatures. This becomes very important as no gustatory cell was reported from previous researches on the fingerling digestive tract. A slice of nasal cavity of ...

  12. Finite volume simulation of 2-D steady square lid driven cavity flow at high reynolds numbers

    Directory of Open Access Journals (Sweden)

    K. Yapici

    2013-12-01

    Full Text Available In this work, computer simulation results of steady incompressible flow in a 2-D square lid-driven cavity up to Reynolds number (Re 65000 are presented and compared with those of earlier studies. The governing flow equations are solved by using the finite volume approach. Quadratic upstream interpolation for convective kinematics (QUICK is used for the approximation of the convective terms in the flow equations. In the implementation of QUICK, the deferred correction technique is adopted. A non-uniform staggered grid arrangement of 768x768 is employed to discretize the flow geometry. Algebraic forms of the coupled flow equations are then solved through the iterative SIMPLE (Semi-Implicit Method for Pressure-Linked Equation algorithm. The outlined computational methodology allows one to meet the main objective of this work, which is to address the computational convergence and wiggled flow problems encountered at high Reynolds and Peclet (Pe numbers. Furthermore, after Re > 25000 additional vortexes appear at the bottom left and right corners that have not been observed in earlier studies.

  13. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin

    Directory of Open Access Journals (Sweden)

    Jorge Henrique Stefaneli Marques

    2018-03-01

    Full Text Available Abstract: The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10: MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80 was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01. MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  14. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin.

    Science.gov (United States)

    Stefaneli Marques, Jorge Henrique; Silva-Sousa, Yara Teresinha Corrêa; Rached-Júnior, Fuad Jacob Abi; Macedo, Luciana Martins Domingues de; Mazzi-Chaves, Jardel Francisco; Camilleri, Josette; Sousa-Neto, Manoel Damião

    2018-03-08

    The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  15. Minimization of power consumption during charging of superconducting accelerating cavities

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, Anirban Krishna, E-mail: anirban.bhattacharyya@physics.uu.se; Ziemann, Volker; Ruber, Roger; Goryashko, Vitaliy

    2015-11-21

    The radio frequency cavities, used to accelerate charged particle beams, need to be charged to their nominal voltage after which the beam can be injected into them. The standard procedure for such cavity filling is to use a step charging profile. However, during initial stages of such a filling process a substantial amount of the total energy is wasted in reflection for superconducting cavities because of their extremely narrow bandwidth. The paper presents a novel strategy to charge cavities, which reduces total energy reflection. We use variational calculus to obtain analytical expression for the optimal charging profile. Energies, reflected and required, and generator peak power are also compared between the charging schemes and practical aspects (saturation, efficiency and gain characteristics) of power sources (tetrodes, IOTs and solid state power amplifiers) are also considered and analysed. The paper presents a methodology to successfully identify the optimal charging scheme for different power sources to minimize total energy requirement.

  16. Minimization of power consumption during charging of superconducting accelerating cavities

    International Nuclear Information System (INIS)

    Bhattacharyya, Anirban Krishna; Ziemann, Volker; Ruber, Roger; Goryashko, Vitaliy

    2015-01-01

    The radio frequency cavities, used to accelerate charged particle beams, need to be charged to their nominal voltage after which the beam can be injected into them. The standard procedure for such cavity filling is to use a step charging profile. However, during initial stages of such a filling process a substantial amount of the total energy is wasted in reflection for superconducting cavities because of their extremely narrow bandwidth. The paper presents a novel strategy to charge cavities, which reduces total energy reflection. We use variational calculus to obtain analytical expression for the optimal charging profile. Energies, reflected and required, and generator peak power are also compared between the charging schemes and practical aspects (saturation, efficiency and gain characteristics) of power sources (tetrodes, IOTs and solid state power amplifiers) are also considered and analysed. The paper presents a methodology to successfully identify the optimal charging scheme for different power sources to minimize total energy requirement.

  17. Transient mixed convection in a channel with an open cavity filled with porous media

    International Nuclear Information System (INIS)

    Buonomo, B; Cresci, G; Manca, O; Mesolella, P; Nardini, S

    2012-01-01

    In this work transient mixed convection in a porous medium in a horizontal channel with a open cavity below is studied numerically. The cavity presents a heated wall at uniform heat flux and the other walls of the cavity and the channel are assumed adiabatic. Air flows through the horizontal channel. The heated wall of the cavity experiences a uniform heat flux in such a way that the forced flow is perpendicular to the motion due to natural convection. The study is carried out employing Brinkman-Forchheimer-extended Darcy model and two energy equations due to the local thermal non-equilibrium assumption. The flow in the channel is assumed to be two-dimensional, laminar, incompressible. Boussinesq approximation is considered. The thermophysical properties of the fluid are evaluated at the ambient temperature. The results for stream function and temperature distribution given at different times are obtained. Wall temperature value are given and also, the velocity and temperature profiles in several sections of the cavity are presented. In addition, the Nusselt number, both local and average, is presented along with the temporal variations of the average Nusselt number.

  18. Viscous dissipation and radiation effects on MHD natural convection in a square enclosure filled with a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Sameh E., E-mail: sameh_sci_math@yahoo.com [Department of Mathematics, Faculty of Sciences, South Valley University, Qena (Egypt); Hussein, Ahmed Kadhim, E-mail: ahmedkadhim7474@gmail.com [College of Engineering, Mechanical Engineering Department, Babylon University, Babylon City—Hilla (Iraq); Mohammed, H.A. [Department of Thermofluids, Faculty of Mechanical Engineering, University Teknologi Malaysia (UTM), 81310 UTM Skudai, Johor Bahru (Malaysia); Adegun, I.K. [Department of Mechanical Engineering, University of Ilorin, Ilorin (Nigeria); Zhang, Xiaohui [School of Physics Science and Technology, School of Energy—Soochow University, Suzhou 215006, Jiangsu (China); Kolsi, Lioua [Unite de Metrologie en Mecanique des Fluides et Thermique, Ecole Nationale d’Ingenieurs, Monastir (Tunisia); Hasanpour, Arman [Department of Mechanical Engineering, Babol University of Technology, PO Box 484, Babol (Iran, Islamic Republic of); Sivasankaran, S. [Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur 50603 (Malaysia)

    2014-01-15

    Highlights: • Ha decelerates the flow field. • Ha enhances conduction. • Magnetic field orientation is important. • Radiation parameter important. • Nu decreases as Ha increases. -- Abstract: Numerical two-dimensional analysis using finite difference approach with “line method” is performed on the laminar magneto-hydrodynamic natural convection in a square enclosure filled with a porous medium to investigate the effects of viscous dissipation and radiation. The enclosure heated from left vertical sidewall and cooled from an opposing right vertical sidewall. The top and bottom walls of the enclosure are considered adiabatic. The flow in the square enclosure is subjected to a uniform magnetic field at various orientation angles (φ = 0°, 30°, 45°, 60° and 90°). Numerical computations occur at wide ranges of Rayleigh number, viscous dissipation parameter, magnetic field orientation angles, Hartmann number and radiation parameter. Numerical results are presented with the aid of tables and graphical illustrations. The results of the present work explain that the local and average Nusselt numbers at the hot and cold sidewalls increase with increasing the radiation parameter. From the other side, the role of viscous dissipation parameter is to reduce the local and average Nusselt numbers at the hot left wall, while it improves them at the cold right wall. The results are compared with another published results and it found to be in a good agreement.

  19. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation.

    Science.gov (United States)

    Benetti, A R; Havndrup-Pedersen, C; Honoré, D; Pedersen, M K; Pallesen, U

    2015-01-01

    The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk-fill materials produced a significantly larger depth of cure and polymerization contraction. Although most of the bulk-fill materials exhibited a gap formation similar to that of the conventional resin composite, two of the low-viscosity bulk-fill resin composites, x-tra base and Venus Bulk Fill, produced larger gaps.

  20. Superconducting cavity driving with FPGA controller

    Energy Technology Data Exchange (ETDEWEB)

    Czarski, T.; Koprek, W.; Pozniak, K.T.; Romaniuk, R.S. [Warsaw Univ. of Technology (Poland); Simrock, S.; Brand, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chase, B.; Carcagno, R.; Cancelo, G. [Fermi National Accelerator Lab., Batavia, IL (United States); Koeth, T.W. [Rutgers - the State Univ. of New Jersey, NJ (United States)

    2006-07-01

    The digital control of several superconducting cavities for a linear accelerator is presented. The laboratory setup of the CHECHIA cavity and ACC1 module of the VU-FEL TTF in DESY-Hamburg have both been driven by a Field Programmable Gate Array (FPGA) based system. Additionally, a single 9-cell TESLA Superconducting cavity of the FNPL Photo Injector at FERMILAB has been remotely controlled from WUT-ISE laboratory with the support of the DESY team using the same FPGA control system. These experiments focused attention on the general recognition of the cavity features and projected control methods. An electrical model of the resonator was taken as a starting point. Calibration of the signal path is considered key in preparation for the efficient driving of a cavity. Identification of the resonator parameters has been proven to be a successful approach in achieving required performance; i.e. driving on resonance during filling and field stabilization during flattop time while requiring reasonable levels of power consumption. Feed-forward and feedback modes were successfully applied in operating the cavities. Representative results of the experiments are presented for different levels of the cavity field gradient. (orig.)

  1. Superconducting cavity driving with FPGA controller

    International Nuclear Information System (INIS)

    Czarski, T.; Koprek, W.; Pozniak, K.T.; Romaniuk, R.S.; Simrock, S.; Brand, A.; Chase, B.; Carcagno, R.; Cancelo, G.; Koeth, T.W.

    2006-01-01

    The digital control of several superconducting cavities for a linear accelerator is presented. The laboratory setup of the CHECHIA cavity and ACC1 module of the VU-FEL TTF in DESY-Hamburg have both been driven by a Field Programmable Gate Array (FPGA) based system. Additionally, a single 9-cell TESLA Superconducting cavity of the FNPL Photo Injector at FERMILAB has been remotely controlled from WUT-ISE laboratory with the support of the DESY team using the same FPGA control system. These experiments focused attention on the general recognition of the cavity features and projected control methods. An electrical model of the resonator was taken as a starting point. Calibration of the signal path is considered key in preparation for the efficient driving of a cavity. Identification of the resonator parameters has been proven to be a successful approach in achieving required performance; i.e. driving on resonance during filling and field stabilization during flattop time while requiring reasonable levels of power consumption. Feed-forward and feedback modes were successfully applied in operating the cavities. Representative results of the experiments are presented for different levels of the cavity field gradient. (orig.)

  2. Optimization of foam-filled bitubal structures for crashworthiness criteria

    International Nuclear Information System (INIS)

    Zhang, Yong; Sun, Guangyong; Li, Guangyao; Luo, Zhen; Li, Qing

    2012-01-01

    Highlights: ► The paper aims to optimize foam-filled bitubal squared column for crashworthiness. ► It explores different formulations and configurations of design. ► The optimal foam-filled bitubal column is better than foam-filled monotubal column. ► The optimal foam-filled bitubal column is better than empty bitubal column. -- Abstract: Thin-walled structures have been widely used as key components in automobile and aerospace industry to improve the crashworthiness and safety of vehicles while maintaining overall light-weight. This paper aims to explore the design issue of thin-walled bitubal column structures filled with aluminum foam. As a relatively new filler material, aluminum foam can increase crashworthiness without sacrificing too much weight. To optimize crashworthiness of the foam-filled bitubal square column, the Kriging meta-modeling technique is adopted herein to formulate the objective and constraint functions. The genetic algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) are used to seek the optimal solutions to the single and multiobjective optimization problems, respectively. To compare with other thin-walled configurations, the design optimization is also conducted for empty bitubal column and foam-filled monotubal column. The results demonstrate that the foam-filled bitubal configuration has more room to enhance the crashworthiness and can be an efficient energy absorber.

  3. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  4. Process Factors Influence on Cavity Pressure Behavior in Microinjection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C. A.; Dimov, S. S.; Scholz, S.

    2011-01-01

    about the filling behavior of different polymer melts. In this paper, a pressure sensor mounted inside a tool cavity was employed to analyse maximum cavity pressure, pressure increase rate during filling and pressure work. The influence of four mu IM parameters, melt temperature, mould temperature......Process monitoring of microinjection moulding (mu IM) is of crucial importance when analysing the effect of different parameter settings on the process and then in assessing its quality. Quality factors related to cavity pressure can provide valuable information about the process dynamics and also......, injection speed, and packing pressure on these three pressure-related process parameters was investigated. A design of experiment study was conducted by moulding a test part, a microfluidic component, in three different polymer materials, PP, ABS, and PC. The results show a similar process behavior for all...

  5. Analysis of natural convection in nanofluid-filled H-shaped cavity by entropy generation and heatline visualization using lattice Boltzmann method

    Science.gov (United States)

    Rahimi, Alireza; Sepehr, Mohammad; Lariche, Milad Janghorban; Mesbah, Mohammad; Kasaeipoor, Abbas; Malekshah, Emad Hasani

    2018-03-01

    The lattice Boltzmann simulation of natural convection in H-shaped cavity filled with nanofluid is performed. The entropy generation analysis and heatline visualization are employed to analyze the considered problem comprehensively. The produced nanofluid is SiO2-TiO2/Water-EG (60:40) hybrid nanofluid, and the thermal conductivity and dynamic viscosity of used nanofluid are measured experimentally. To use the experimental data of thermal conductivity and dynamic viscosity, two sets of correlations based on temperature for six different solid volume fractions of 0.5, 1, 1.5, 2, 2.5 and 3 vol% are derived. The influences of different governing parameters such different aspect ratio, solid volume fractions of nanofluid and Rayleigh numbers on the fluid flow, temperature filed, average/local Nusselt number, total/local entropy generation and heatlines are presented.

  6. Influence of inclined Lorentz force on micropolar fluids in a square cavity with uniform and nonuniform heated thin plate

    Energy Technology Data Exchange (ETDEWEB)

    Periyadurai, K. [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Muthtamilselvan, M., E-mail: muthtamill@yahoo.co.in [Department of Mathematics, Bharathiar University, Coimbatore 641046, Tamil Nadu (India); Doh, Deog-Hee [Division of Mechanical Engineering, College of Engineering,Korea Maritime Ocean University, Busan 606781 (Korea, Republic of)

    2016-12-15

    In the present study, the effect of inclined magnetic field on natural convection of micro-polar fluid in a square cavity with uniform and nonuniform heated thin plate built in centrally is investigated numerically. The vertical walls are cooled while the top and bottom walls are insulated. The thin plate is assumed to be isothermal with a linearly varying temperature. The governing equations were solved by finite volume method using second order central difference scheme and upwind differencing scheme. The numerical investigation is carried out for different governing parameters namely, the Hartmann number, inclination angle of magnetic field, Rayleigh number, vortex viscosity and source non-uniformity parameters. The result shows that the heat transfer rate is decreased when increasing Hartmann number, inclination angle of magnetic field and vortex viscosity parameter. It is found that the non-uniformity parameter affects the fluid flow and temperature distribution especially for the high Rayleigh numbers. Finally, the overall heat transfer rate of micro-polar fluids is found to be smaller than that of Newtonian fluid. - Highlights: • We investigate the effect of inclined magnetic field on micropolar fluid in a cavity. • The effects of uniform and non-uniform heated plate are studied. • The present numerical results are compared with the experimental results. • The addition of vortex viscosity parameter declines the heat transfer performance. • The high heat transfer rate occurs in the vertical plate compared to the horizontal one.

  7. Onset of transition from laminar to chaos in MHD mixed convection of a lid-driven trapezoidal cavity filled with Cu-water nanofluid

    Energy Technology Data Exchange (ETDEWEB)

    Azam, Mohammad, E-mail: azam09mebuet@gmail.com; Hasanuzzaman, Md., E-mail: hasanuzzaman138@gmail.com; Saha, Sumon, E-mail: sumonsaha@me.buet.ac.bd [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka 1000 (Bangladesh)

    2016-07-12

    The present study investigates the thermal mixing scenarios of steady magneto-hydrodynamic (MHD) mixed convection in a two-dimensional lid-driven trapezoidal cavity filled with Cu-water nanofluid. The top wall of the cavity slides with a uniform velocity from left to right direction, while the other walls are fixed. The bottom wall is kept with a constant higher temperature than the top one. The governing mass, momentum and energy equations are expressed in non-dimensional forms and Galerkin finite element method has been employed to solve these equations. Special attention is paid on investigating the onset of transition from laminar to chaos at pure mixed convection case. Hence, the computations are carried out for a wide range of Reynolds numbers (Re = 0.1 − 400) and Grashof numbers (Gr = 10{sup −2} − 1.6 × 10{sup 5}) at unity Richardson number and fixed Hartmann number (Ha = 10). The variation of average Nusselt number of the bottom heated wall indicates the influence of governing parameters (Re and Gr) on heat transfer characteristics. The results are presented and explained through the visualisation of isotherms, streamlines and heatlines.

  8. Cuspal Flexure and Extent of Cure of a Bulk-fill Flowable Base Composite.

    Science.gov (United States)

    Francis, A V; Braxton, A D; Ahmad, W; Tantbirojn, D; Simon, J F; Versluis, A

    2015-01-01

    To investigate a bulk-fill flowable base composite (Surefil SDR Flow) in terms of cuspal flexure and cure when used in incremental or bulk techniques. Mesio-occluso-distal cavities (4 mm deep, 4 mm wide) were prepared in 24 extracted molars. The slot-shaped cavities were etched, bonded, and restored in 1) two 2-mm increments Esthet-X HD (control), 2) two 2-mm increments Surefil SDR Flow, or 3) 4-mm bulk Surefil SDR Flow (N=8). The teeth were digitized after preparation (baseline) and restoration and were precisely aligned to calculate cuspal flexure. Restored teeth were placed in fuchsin dye for 16 hours to determine occlusal bond integrity from dye penetration. Extent of cure was assessed by hardness at 0.5-mm increments through the restoration depth. Results were analyzed with analysis of variance and Student-Newman-Keuls post hoc tests (α=0.05). Surefil SDR Flow, either incrementally or bulk filled, demonstrated significantly less cuspal flexure than Esthet-X HD. Dye penetration was less than 3% of cavity wall height and was not statistically different among groups. The hardness of Surefil SDR Flow did not change throughout the depth for both incrementally and bulk filled restorations; the hardness of Esthet-X HD was statistically significantly lower at the bottom of each increment than at the top. Filling in bulk or increments made no significant difference in marginal bond quality or cuspal flexure for the bulk-fill composite. However, the bulk-fill composite caused less cuspal flexure than the incrementally placed conventional composite. The bulk-fill composite cured all the way through (4 mm), whereas the conventional composite had lower cure at the bottom of each increment.

  9. Different optical properties in different periodic slot cavity geometrical morphologies

    Science.gov (United States)

    Zhou, Jing; Shen, Meng; Du, Lan; Deng, Caisong; Ni, Haibin; Wang, Ming

    2016-09-01

    In this paper, optical properties of two-dimensional periodic annular slot cavity arrays in hexagonal close-packing on a silica substrate are theoretically characterized by finite difference time domain (FDTD) simulation method. By simulating reflectance spectra, electric field distribution, and charge distribution, we confirm that multiple cylindrical surface plasmon resonances can be excited in annular inclined slot cavities by linearly polarized light, in which the four reflectance dips are attributed to Fabry-Perot cavity resonances in the coaxial cavity. A coaxial waveguide mode TE11 will exist in these annular cavities, and the wavelengths of these reflectance dips are effectively tailored by changing the geometrical pattern of slot cavity and the dielectric materials filled in the cavities. These resonant wavelengths are localized in annular cavities with large electric field enhancement and dissipate gradually due to metal loss. The formation of an absorption peak can be explained from the aspect of phase matching conditions. We observed that the proposed structure can be tuned over the broad spectral range of 600-4000 nm by changing the outer and inner radii of the annular gaps, gap surface topography. Meanwhile, different lengths of the cavity may cause the shift of resonance dips. Also, we study the field enhancement at different vertical locations of the slit. In addition, dielectric materials filling in the annular gaps will result in a shift of the resonance wavelengths, which make the annular cavities good candidates for refractive index sensors. The refractive index sensitivity of annular cavities can also be tuned by the geometry size and the media around the cavity. Annular cavities with novel applications can be implied as surface enhanced Raman spectra substrates, refractive index sensors, nano-lasers, and optical trappers. Project supported by the National Natural Science Foundation of China (Grant No. 61178044), the Natural Science Foundation

  10. Adiabatic partition effect on natural convection heat transfer inside a square cavity

    DEFF Research Database (Denmark)

    Mahmoudi Nezhad, Sajjad; Rezaniakolaei, Alireza; yousefi, Tooraj

    2018-01-01

    A steady state and two-dimensional laminar free convection heat transfer in a partitioned cavity with horizontal adiabatic and isothermal side walls is investigated using both experimental and numerical approaches. The experiments and numerical simulations are carried out using a Mach......-Zehnder interferometer and a finite volume code, respectively. A horizontal and adiabatic partition, with angle of θ is adjusted such that it separates the cavity into two identical parts. Effects of this angel as well as Rayleigh number on the heat transfer from the side-heated walls are investigated in this study...... partition angle, the results show that the average Nusselt number and consequently the heat transfer enhance as the Rayleigh number increases. However, for a given Rayleigh number the maximum and the minimum heat transfer occurs at θ = 45°and θ = 90°, respectively. Two responsible mechanisms...

  11. Nonlinear Analysis of Cavities in Rock Salt

    DEFF Research Database (Denmark)

    Ottosen, N. S.; Krenk, Steen

    1979-01-01

    The paper covers some material and computational aspects of the rock mechanics of leached cavities in salt. A material model is presented in which the instantaneous stiffness of the salt is obtained by interpolation between the unloaded state and a relevant failure state. The model enables predic...... prediction of short term triaxial behaviour from uniaxial stress-strain curves. Key results from a nonlinear finite element calculation of a gas-filled cavity are given, and the general features are related to a simple nonlinear method of stress evaluation....

  12. The DAΦNE 3RD harmonic cavity

    International Nuclear Information System (INIS)

    Alesini, D.; Boni, R.; Clozza, A.; Gallo, A.; Guiducci, S.; Marcellini, F.; Migliorati, M.; Palumbo, L.; Pellegrino, L.; Sgamma, F.; Zobov, M.

    2001-01-01

    The installation of a passive 3rd harmonic cavity in both the e + and e - rings of the Frascati Φ-factory DAΦNE has been decided in order to improve the Touschek lifetime by increasing the bunch length. The implications of the RF harmonic system on the beam dynamics, in particular those related to the gap in the bunch filling pattern, have been carefully studied by means of analytical and numerical tools. A single-cell cavity incorporating a ferrite ring for the HOM damping has been designed through the extensive use of MAFIA and HFSS simulation codes. One cavity prototype has been built and extensively bench tested, while the fabrication of the two final cavities is almost completed. A description of the design and construction activities, and a set of experimental measurements are reported in this paper

  13. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests

    Directory of Open Access Journals (Sweden)

    Fernanda Ferrari Esteves TORRES

    Full Text Available Abstract Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. Material and Methods Solubility (loss of mass after 7 and 30 days, and dimensional stability (in mm were evaluated in accordance with Carvalho-Junior, et al. 7 (2007. The filling ability and volumetric change (in mm3 were evaluated by Micro-CT (Bruker-MicroCT, Kontich, Belgium using resin models with cavities 3 mm deep and 1 mm in diameter. The cavities were filled with materials to evaluate filling ability, and then scanned by Micro-CT. After 7 and 30 days immersed in distilled water, the filled cavities were scanned again to evaluate the volumetric change. MTA Angelus (MTA, Biodentine (BIO and zinc oxide-eugenol cement (ZOE were evaluated. Data were submitted to analysis of variance (ANOVA and Tukey's test with 5% significance level. Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p0.05 at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05. ZOE and BIO showed higher filling ability (p<0.05. Conclusions ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests.

  14. Method and mold for casting thin metal objects

    Science.gov (United States)

    Pehrson, Brandon P; Moore, Alan F

    2014-04-29

    Provided herein are various embodiments of systems for casting thin metal plates and sheets. Typical embodiments include layers of mold cavities that are oriented vertically for casting the metal plates. In some embodiments, the mold cavities include a beveled edge such that the plates that are cast have a beveled edge. In some embodiments, the mold cavities are filled with a molten metal through an open horizontal edge of the cavity. In some embodiments, the mold cavities are filled through one or more vertical feed orifices. Further disclosed are methods for forming a thin cast metal plate or sheet where the thickness of the cast part is in a range from 0.005 inches to 0.2 inches, and the surface area of the cast part is in a range from 16 square inches to 144 square inches.

  15. Method for casting thin metal objects

    Science.gov (United States)

    Pehrson, Brandon P; Moore, Alan F

    2015-04-14

    Provided herein are various embodiments of systems for casting thin metal plates and sheets. Typical embodiments include layers of mold cavities that are oriented vertically for casting the metal plates. In some embodiments, the mold cavities include a beveled edge such that the plates that are cast have a beveled edge. In some embodiments, the mold cavities are filled with a molten metal through an open horizontal edge of the cavity. In some embodiments, the mold cavities are filled through one or more vertical feed orifices. Further disclosed are methods for forming a thin cast metal plate or sheet where the thickness of the cast part is in a range from 0.005 inches to 0.2 inches, and the surface area of the cast part is in a range from 16 square inches to 144 square inches.

  16. Sealing of minimally invasive Class II fillings (slot) using an adhesive patch: sealant margin extension for prevention.

    Science.gov (United States)

    Schmidlin, Patrick R; Seemann, Rainer; Filli, Tilla; Attin, Thomas; Imfeld, Thomas

    2007-01-01

    A laboratory study was performed to assess the potential of an adhesive patch to seal small, unbeveled, Class II, box-only (slot) composite fillings. After minimal access cavity preparation with an 80 pm diamond bur, 40 box-only Class II cavities were prepared mesially and distally in 20 extracted human molars using a u-shaped PCS insert (EMS). One cavity per tooth was adhesively filled with a hybrid composite material in one increment. A patch, acting as an adhesive matrice, was applied to the other cavity of each tooth to seal the restoration. The margin of the patch was located in areas easily accessible to oral hygiene measures and self-cleaning. All the teeth were subjected to thermo-mechanical stress in a computer-controlled masticator device. In 10 teeth, caries was induced in a microbial-based artificial mouth model and quantitatively determined by confocal laser scanning microscopy. Microleakage was assessed in the other 10 teeth in two planar sections after immersion in 0.5% basic fuchsin solution. The results showed no demineralization at the filling margins protected with the patch. Microleakage was observed in one sample only and was limited to the enamel. In contrast, the margins of fillings without the patch application showed a mean demineralization depth of 146 +/- 42 microm and dye penetration into the dentin in five sections. This innovative approach to sealing restorative margins with an adhesive patch results in less leakage and filling margin demineralization and merits further investigation.

  17. Middle ear cavity morphology is consistent with an aquatic origin for testudines.

    Directory of Open Access Journals (Sweden)

    Katie L Willis

    Full Text Available The position of testudines in vertebrate phylogeny is being re-evaluated. At present, testudine morphological and molecular data conflict when reconstructing phylogenetic relationships. Complicating matters, the ecological niche of stem testudines is ambiguous. To understand how turtles have evolved to hear in different environments, we examined middle ear morphology and scaling in most extant families, as well as some extinct species, using 3-dimensional reconstructions from micro magnetic resonance (MR and submillimeter computed tomography (CT scans. All families of testudines exhibited a similar shape of the bony structure of the middle ear cavity, with the tympanic disk located on the rostrolateral edge of the cavity. Sea Turtles have additional soft tissue that fills the middle ear cavity to varying degrees. When the middle ear cavity is modeled as an air-filled sphere of the same volume resonating in an underwater sound field, the calculated resonances for the volumes of the middle ear cavities largely fell within testudine hearing ranges. Although there were some differences in morphology, there were no statistically significant differences in the scaling of the volume of the bony middle ear cavity with head size among groups when categorized by phylogeny and ecology. Because the cavity is predicted to resonate underwater within the testudine hearing range, the data support the hypothesis of an aquatic origin for testudines, and function of the middle ear cavity in underwater sound detection.

  18. Thoracic cavity after thoracic operations

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.

    1983-01-01

    The problems of roentgenologic method application to detect postoperative c omplications in pulmonary tissue, bronchi, pleural cavity, mediastinum, have been considered. It is shown, that the use of the above mentioned method permit s to judge on the rates and degrees of the lungs straightening, anatomic structures shift, the change in air- and blood-filling, accumulation of liquid a nd air in pleuritic

  19. Squares of Random Linear Codes

    DEFF Research Database (Denmark)

    Cascudo Pueyo, Ignacio; Cramer, Ronald; Mirandola, Diego

    2015-01-01

    a positive answer, for codes of dimension $k$ and length roughly $\\frac{1}{2}k^2$ or smaller. Moreover, the convergence speed is exponential if the difference $k(k+1)/2-n$ is at least linear in $k$. The proof uses random coding and combinatorial arguments, together with algebraic tools involving the precise......Given a linear code $C$, one can define the $d$-th power of $C$ as the span of all componentwise products of $d$ elements of $C$. A power of $C$ may quickly fill the whole space. Our purpose is to answer the following question: does the square of a code ``typically'' fill the whole space? We give...

  20. Posterior bulk-filled resin composite restorations. A 5-year randomized controlled clinical study

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    mm as needed to fill the cavity 2 mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2 mm increments. The restorations were evaluated using slightly......, 4 SDR-CeramX mono+ and 6 CeramX mono +-only restorations. The main reasons for failure were tooth fracture (6) and secondary caries (4). The annual failure rate (AFR) for all restorations (Class I and II) was for the bulk-filled-1.1% and for the resin composite-only restorations 1.3% (p = 0...

  1. [Oral health among adolescents: aspects relating to hygiene, dental cavities and periodontal disease in the cities of Recife and Feira de Santana, Brazil].

    Science.gov (United States)

    Nogueira dos Santos, Nilton Cesar; Alves, Tecia Daltro Borges; Freitas, Valéria Souza; Jamelli, Silvia Regina; Cavalcanti Sarinho, Emanuel Sávio

    2007-01-01

    To characterize the oral health in adolescents in the cities of Recife and Feira de Santana, Northeast Brazil by assessment of personal hygiene and dental cavities and periodontal disease. Forty adolescents between ten and eighteen years old were assessed through an exploratory study run in Recife in 2005. In Feira de Santana, 971 adolescents (twelve years old) were examined through a cross section study in 2002. It was assessed cavity status through the number of cavitied, missing and filled teeth, visible dental plaque, bleeding gums and periodontal status. The analysis was based on Chi-Square, Kruskall-Wallis and Fisher tests, with a confidence interval of 95%. The most of adolescents followed oral hygiene practices three times a day. The DMTF values presented a median of 1.5 in Recife and averages of 1.89 in state schools, 2.17 in municipal schools and 2.39 in private schools in Feira de Santana. The bleeding gum in Recife presented a median of 27%, and in Feira de Santana the healthy sextant averages of 4.36, 4.08 and 5.16 in state, municipal and private schools respectively. The frequency of the dental cavities was low, with most of the adolescents reporting good habits of oral hygiene and favorable periodontal conditions.

  2. Grain boundary cavity growth under applied stress and internal pressure

    International Nuclear Information System (INIS)

    Mancuso, J.F.

    1977-08-01

    The growth of grain boundary cavities under applied stress and internal gas pressure was investigated. Methane gas filled cavities were produced by the C + 4H reversible CH4 reaction in the grain boundaries of type 270 nickel by hydrogen charging in an autoclave at 500 0 C with a hydrogen pressure of either 3.4 or 14.5 MPa. Intergranular fracture of nickel was achieved at a charging temperature of 300 0 C and 10.3 MPa hydrogen pressure. Cavities on the grain boundaries were observed in the scanning electron microscope after fracture. Photomicrographs of the cavities were produced in stereo pairs which were analyzed so as to correct for perspective distortion and also to determine the orientational dependence of cavity growth under an applied tensile stress

  3. The response of liquid-filled pipes to vapour collapse

    International Nuclear Information System (INIS)

    Tijsseling, A.S.; Fan, D.

    1991-01-01

    The collapse of vapour cavities in liquid is usually accompanied with almost instantaneous pressure rises. These pressure rises impose severe loads on liquid-conveying pipes whenever the cavities become sufficiently large. Due to the impact nature of loadings, movement of the pipe walls can be expected. Tests are performed in a water-filled closed pipe suspended by thin steel wires. Vaporous cavities are induced in the liquid by hitting the pipe axially by a steel rod. The volume of the cavities can be varied by changing the initial pressure of the water. The developing and collapsing of cavities in the liquid is inferred from pressure measurements. Strain gauges and a laser Doppler vibrometer are used to record the response of the pipe to these pressures. The test results are compared with predictions from a numerical model. The model describes 1) axial stress wave propagations in the pipe and 2) water hammer and cavitation phenomena in the liquid. Pipe and liquid interact via 1) the radial expansion and contraction of the pipe wall and 2) the closed ends of the pipe, where large vapour cavities may develop. (author)

  4. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... position was measured on the polymer μ-parts to evaluate filling behavior of the polymer melt flowing through μ-features. Experimental results obtained under different processing conditions were evaluated to correlate the process parameter levels influence on the selected responses. Results showed...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  5. Mode coupling in hybrid square-rectangular lasers for single mode operation

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Xiu-Wen; Huang, Yong-Zhen, E-mail: yzhuang@semi.ac.cn; Yang, Yue-De; Xiao, Jin-Long; Weng, Hai-Zhong; Xiao, Zhi-Xiong [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors and University of Chinese Academy of Sciences, Chinese Academy of Sciences, Beijing 100083 (China)

    2016-08-15

    Mode coupling between a square microcavity and a Fabry-Pérot (FP) cavity is proposed and demonstrated for realizing single mode lasers. The modulations of the mode Q factor as simulation results are observed and single mode operation is obtained with a side mode suppression ratio of 46 dB and a single mode fiber coupling loss of 3.2 dB for an AlGaInAs/InP hybrid laser as a 300-μm-length and 1.5-μm-wide FP cavity connected to a vertex of a 10-μm-side square microcavity. Furthermore, tunable single mode operation is demonstrated with a continuous wavelength tuning range over 10 nm. The simple hybrid structure may shed light on practical applications of whispering-gallery mode microcavities in large-scale photonic integrated circuits and optical communication and interconnection.

  6. Resonant cavity enhanced multi-analyte sensing

    Science.gov (United States)

    Bergstein, David Alan

    Biological research and medicine increasingly depend on interrogating binding interactions among small segments of DNA, RNA, protein, and bio-specific small molecules. Microarray technology, which senses the affinity for target molecules in solution for a multiplicity of capturing agents fixed to a surface, has been used in biological research for gene expression profiling and in medicine for molecular biomarker detection. Label-free affinity sensing is preferable as it avoids fluorescent labeling of the target molecules, reducing test cost and variability. The Resonant Cavity Imaging Biosensor (RCIB) is a label-free optical inference based technique introduced that scales readily to high throughput and employs an optical resonant cavity to enhance sensitivity by a factor of 100 or more. Near-infrared light centered at 1512.5 nm couples resonantly through a cavity constructed from Si/SiO2 Bragg reflectors, one of which serves as the binding surface. As the wavelength is swept 5 nm, an Indium-Gallium-Arsenide digital camera monitors cavity transmittance at each pixel with resolution 128 x 128. A wavelength shift in the local resonant response of the optical cavity indicates binding. Positioning the sensing surface with respect to the standing wave pattern of the electric field within the cavity, one can control the sensitivity of the measurement to the presence of bound molecules thereby enhancing or suppressing sensitivity where appropriate. Transmitted intensity at thousands of pixel locations are recorded simultaneously in a 10 s, 5 nm scan. An initial proof-of-principle setup was constructed. A sample was fabricated with 25, 100 mum wide square regions, each with a different density of 1 mum square depressions etched 12 nm into the S1O 2 surface. The average depth of each etched region was found with 0.05 nm RMS precision when the sample remains loaded in the setup and 0.3 nm RMS precision when the sample is removed and replaced. Selective binding of the protein

  7. Low- to medium-β cavities for heavy ion acceleration

    Science.gov (United States)

    Facco, Alberto

    2017-02-01

    Acceleration of low- and medium-β heavy ions by means of superconducting (SC) linear accelerators (linacs) was made possible by the development, during four decades, of a particular class of cavities characterized by low operation frequency, several different shapes and different electromagnetic modes of operation. Their performance, initially rather poor in operating accelerators, have steadily increased along with the technological progress and nowadays the gap with the high-β, elliptical cavities is close to be filled. Initially confined to a very small number of applications, this family of cavities evolved in many directions becoming one of the most widespread in linacs. Nowadays it is present in the majority of superconducting radio-frequency ion linac projects worldwide. An overview of low- and medium-β SC cavities for heavy ions, focused on their recent evolution and achievements, will be given.

  8. High-Q silicon-on-insulator slot photonic crystal cavity infiltrated by a liquid

    International Nuclear Information System (INIS)

    Caër, Charles; Le Roux, Xavier; Cassan, Eric

    2013-01-01

    We report the experimental realization of a high-Q slot photonic crystal cavity in Silicon-On-Insulator (SOI) configuration infiltrated by a liquid. Loaded Q-factor of 23 000 is measured at telecom wavelength. The intrinsic quality factor inferred from the transmission spectrum is higher than 200 000, which represents a record value for slot photonic crystal cavities on SOI, whereas the maximum of intensity of the cavity is roughly equal to 20% of the light transmitted in the waveguide. This result makes filled slot photonic crystal cavities very promising for silicon-based light emission and ultrafast nonlinear optics

  9. Direct simulation of natural convection in square porous enclosure

    International Nuclear Information System (INIS)

    Pourshaghaghy, A.; Hakkaki-Fard, A.; Mahdavi-Nejad, A.

    2007-01-01

    In this article, natural convection in a square porous enclosure is simulated by a direct numerical method. The solution method is based on a random distribution of solid blocks, which resembles the porous media within the cavity. The Navier-Stokes equations are solved directly in the fluid region without the assumption of volume averaging. The no-slip condition is applied on the surface of any solid particle, and the energy transport equation is solved separately for the solid phase and fluid flow. The local and average Nusselt numbers are presented for steady state for two different cases of thermal boundary conditions of the cavity walls. An oscillatory solution is observed for the local Nu number on the surface of the enclosure, and the critical Ra numbers are found in which natural convection flow is started within the cavity

  10. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials.

    Science.gov (United States)

    Moorthy, A; Hogg, C H; Dowling, A H; Grufferty, B F; Benetti, A R; Fleming, G J P

    2012-06-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases. Twenty-four sound upper premolar teeth with Class II cavities were allocated to three groups (n=8). Restoration of the teeth involved the placement of an RBC (GrandioSO) in eight oblique increments (Group A) or Groups B and C were restored to within 2 mm of the palatal cusp in a single increment with bulk-fill flowable RBC bases (SDR and x-tra base) before the two occlusal cavity increments were placed with GrandioSO. Buccal and palatal cusp deflections were recorded postirradiation using a twin channel deflection measuring gauge. Following restoration, the teeth were thermocycled, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage. The mean total cuspal deflection for the oblique incremental restoration technique was 11.26 (2.56) μm (Group A) and 4.63 (1.19) μm (Group B) and 4.73 (0.99) μm (Group C) for the bulk-fill flowable RBC bases. A significant increase in the mean total cuspal deflection for the incrementally filled GrandioSO compared with the SDR (P=0.007) and x-tra base (P=0.005) restored teeth was evident. No significant difference in the cervical microleakage scores was recorded between groups AC (P>0.05). The bulk-fill flowable RBC bases significantly reduced cuspal deflection compared with a conventional RBC restored in an oblique incremental filling technique with no associated change in cervical microleakage recorded. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Transition to chaos in a square enclosure containing internal heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Baytas, A.C. [Institute For Nuclear Energy, Istanbul (Turkey)

    1995-09-01

    A numerical investigation is performed to study the transition from steady to chaotic flow of a fluid confined in a two-dimensional square cavity. The cavity has rigid walls of constant temperature containing uniformly distributed internal heat source. Effects of the Rayleigh number of flow and heat transfer rates are studied. In addition to, same problem is solved for sinusoidally changing internal heat source to show its effect on the flow model and heat transfer of the enclosures. Details of oscillatory solutions and flow bifurcations are presented.

  12. Cavity parameters identification for TESLA control system development

    Energy Technology Data Exchange (ETDEWEB)

    Czarski, T.; Pozniak, K.T.; Romaniuk, R.S. [Warsaw Univ. of Technology (Poland). ELHEP Lab., ISE; Simrock, S. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2005-07-01

    The control system modeling for the TESLA - TeV-Energy Superconducting Linear Accelerator project has been developed for the efficient stabilization of the pulsed, accelerating EM field of the resonator. The cavity parameters identification is an essential task for the comprehensive control algorithm. The TESLA cavity simulator has been successfully implemented by applying very high speed FPGA - Field Programmable Gate Array technology. The electromechanical model of the cavity resonator includes the basic features - Lorentz force detuning and beam loading. The parameters identification bases on the electrical model of the cavity. The model is represented by the state space equation for the envelope of the cavity voltage driven by the current generator and the beam loading. For a given model structure, the over-determined matrix equation is created covering the long enough measurement range with the solution according to the least squares method. A low degree polynomial approximation is applied to estimate the time-varying cavity detuning during the pulse. The measurement channel distortion is considered, leading to the external cavity model seen by the controller. The comprehensive algorithm of the cavity parameters identification has been implemented in the Matlab system with different modes of the operation. Some experimental results have been presented for different cavity operational conditions. The following considerations have lead to the synthesis of the efficient algorithm for the cavity control system predicted for the potential FPGA technology implementation. (orig.)

  13. Cavity parameters identification for TESLA control system development

    International Nuclear Information System (INIS)

    Czarski, T.; Pozniak, K.T.; Romaniuk, R.S.

    2005-01-01

    The control system modeling for the TESLA - TeV-Energy Superconducting Linear Accelerator project has been developed for the efficient stabilization of the pulsed, accelerating EM field of the resonator. The cavity parameters identification is an essential task for the comprehensive control algorithm. The TESLA cavity simulator has been successfully implemented by applying very high speed FPGA - Field Programmable Gate Array technology. The electromechanical model of the cavity resonator includes the basic features - Lorentz force detuning and beam loading. The parameters identification bases on the electrical model of the cavity. The model is represented by the state space equation for the envelope of the cavity voltage driven by the current generator and the beam loading. For a given model structure, the over-determined matrix equation is created covering the long enough measurement range with the solution according to the least squares method. A low degree polynomial approximation is applied to estimate the time-varying cavity detuning during the pulse. The measurement channel distortion is considered, leading to the external cavity model seen by the controller. The comprehensive algorithm of the cavity parameters identification has been implemented in the Matlab system with different modes of the operation. Some experimental results have been presented for different cavity operational conditions. The following considerations have lead to the synthesis of the efficient algorithm for the cavity control system predicted for the potential FPGA technology implementation. (orig.)

  14. Effective slip over partially filled microcavities and its possible failure

    Science.gov (United States)

    Ge, Zhouyang; Holmgren, Hanna; Kronbichler, Martin; Brandt, Luca; Kreiss, Gunilla

    2018-05-01

    Motivated by the emerging applications of liquid-infused surfaces (LIS), we study the drag reduction and robustness of transverse flows over two-dimensional microcavities partially filled with an oily lubricant. Using separate simulations at different scales, characteristic contact line velocities at the fluid-solid intersection are first extracted from nanoscale phase field simulations and then applied to micronscale two-phase flows, thus introducing a multiscale numerical framework to model the interface displacement and deformation within the cavities. As we explore the various effects of the lubricant-to-outer-fluid viscosity ratio μ˜2/μ˜1 , the capillary number Ca, the static contact angle θs, and the filling fraction of the cavity δ , we find that the effective slip is most sensitive to the parameter δ . The effects of μ˜2/μ˜1 and θs are generally intertwined but weakened if δ 1 ), however, are immune to such failure due to their generally larger contact line velocity.

  15. Comparison of the sealing ability of mineral trioxide aggregate and Portland cement used as root-end filling materials.

    Science.gov (United States)

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Eskandarinezhad, Mahsa; Shakouei, Sahar; Unchi, Mahsa

    2011-12-01

    Inadequate apical seal is the major cause of surgical endodontic failure. The root-end filling material used should prevent egress of potential contaminants into periapical tissue. The purpose of this study was to compare the sealing ability of four root-end filling materials: white mineral trioxide aggregate (MTA), gray MTA, white Portland cement (PC) and gray PC by dye leakage test. Ninety-six human single-rooted teeth were instrumented, and obturated with gutta-percha. After resecting the apex, an apical cavity was prepared. The teeth were randomly divided into four experimental groups (A: white MTA, B: gray MTA, C: white PC and D: gray PC; n = 20) and two control groups (positive and negative control groups; n = 8). Root-end cavities in the experimental groups were filled with the experimental materials. The teeth were exposed to Indian ink for 72 hours. The extent of dye penetration was measured with a stereomicroscope at 16× magnification. The negative controls showed no dye penetration and dye penetration was seen in the entire root-end cavity of positive controls. However, there was no statistically significant difference among the four experimental groups (P > 0.05). All retrograde filling materials tested in this study showed the same microleakage in vitro. Given the low cost and apparently similar sealing ability of PC, PC could be considered as a substitute for MTA as a root-end filling material.

  16. Self-cavity lasing in optically pumped single crystals of p-sexiphenyl

    International Nuclear Information System (INIS)

    Yanagi, Hisao; Tamura, Kenji; Sasaki, Fumio

    2016-01-01

    Organic single-crystal self-cavities are prepared by solution growth of p-sexiphenyl (p-6P). Based on Fabry-Pérot feedback inside a quasi-lozenge-shaped platelet crystal, edge-emitting laser is obtained under optical pumping. The multimode lasing band appears at the 0-1 or 0-2 vibronic progressions depending on the excitation conditions which affect the self-absorption effect. Cavity-size dependence of amplified spontaneous emission (ASE) is investigated with laser-etched single crystals of p-6P. As the cavity length of square-shaped crystal is reduced from 100 to 10 μm, ASE threshold fluence is decreased probably due to size-dependent light confinement in the crystal cavity.

  17. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    as well as with the filling of the cavity by the polymer melt. In this paper, two parameters derived from cavity pressure over time (i.e. pressure work). The influence of four µIM parameters (melt temperature, mould temperature, injection speed, aand packing pressure) on the two pressure-related outputs...... has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been......Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...

  18. Physical optimization of a wavy porous cavity filled by nanofluids in the presence of solar radiations using the Box-Behnken design (BBD)

    Science.gov (United States)

    Ghorbanian, A.; Tahari, M.; Hatami, M.

    2017-06-01

    In this paper, the physical optimization of a wavy porous cavity is evaluated while it is filled with nanofluids and under the solar radiation heat flux by using numerical and statistical methods. The effect of four parameters is discussed on the Nusselt number: Wavy amplitude ( Am, solar heat flux, Darcy number and Rayleigh number. To find the effect and interaction of these parameters on the heat transfer, a Box-Behnken design (BBD) is used and analysis is performed on the 27 experiments proposed by BBD. Analysis of variance (ANOVA) of the results revealed that solar heat flux and wave amplitude have a strong effect on the Nusselt number compared to Darcy and Rayleigh numbers. Finally, the response surface methodology (RSM) was applied to find the optimized case while its error was 0.002% in predicting the Nusselt number for the optimized case which confirms the high accuracy of results.

  19. Study on the dependence of the resonance frequency of accelerators on the cavities internal diameter

    International Nuclear Information System (INIS)

    Serrao, V.A.; Franco, M.A.R.; Fuhrmann, C.

    1988-05-01

    The resonance frequencies of individual cavities and of a six cell disk-loaded prototype of an accelerating structure were measured as a function of cavity inner diameter. A linear relationship between the indidual cavity frequency and the six cell stack 2Π/3 mode frequency was obtained that will be very useful during the final tuning of the accelerating strutures of the IEAV linac. The dispersion diagrams were also obtained for various internal cavity diameters; these diagrams were utilized to estimate the group velocity and the RF filling time of the accelerating structure. (author) [pt

  20. On the equilibrium of a black hole in a radiation-filled cavity

    International Nuclear Information System (INIS)

    Wilkins, D.

    1979-01-01

    By using the horizon entropy, Hawking showed that a stable black hole will form inside a radiation cavity of finite energy E and small enough volume, V 10 years is negligible. Second, any such hole should not be in equilibrium, let alone stable; it should evaporate away again because the radiation, with typical wavelength approximately 16 times larger than the hole, can hardly be accreted. Study of the combined accretion and evaporation resolves the difficulty. It confirms the prediction of stability and it does so without appeal to the concept of horizon entropy. A state of pure radiation is actually favored over one including a hole when 1 >= V/Vsub(h) > 0.2556, but the reverse holds for smaller cavity volumes. The horizon entropy of a black hole plays a natural role; it helps determine the system's evolution and equilibria through the condition that the total entropy of hole plus radiation always tends to increase. Using the known temperature of the hole and the fact (deduced from the accretion formula) that energy flows from the hot body to the cold, one easily inverts the reasoning to derive a unique value for the black-hole entropy. (author)

  1. Lasers with intra-cavity phase elements

    Science.gov (United States)

    Gulses, A. Alkan; Kurtz, Russell; Islas, Gabriel; Anisimov, Igor

    2018-02-01

    Conventional laser resonators yield multimodal output, especially at high powers and short cavity lengths. Since highorder modes exhibit large divergence, it is desirable to suppress them to improve laser quality. Traditionally, such modal discriminations can be achieved by simple apertures that provide absorptive loss for large diameter modes, while allowing the lower orders, such as the fundamental Gaussian, to pass through. However, modal discrimination may not be sufficient for short-cavity lasers, resulting in multimodal operation as well as power loss and overheating in the absorptive part of the aperture. In research to improve laser mode control with minimal energy loss, systematic experiments have been executed using phase-only elements. These were composed of an intra-cavity step function and a diffractive out-coupler made of a computer-generated hologram. The platform was a 15-cm long solid-state laser that employs a neodymium-doped yttrium orthovanadate crystal rod, producing 1064 nm multimodal laser output. The intra-cavity phase elements (PEs) were shown to be highly effective in obtaining beams with reduced M-squared values and increased output powers, yielding improved values of radiance. The utilization of more sophisticated diffractive elements is promising for more difficult laser systems.

  2. Apparatus and method for plasma processing of SRF cavities

    Science.gov (United States)

    Upadhyay, J.; Im, Do; Peshl, J.; Bašović, M.; Popović, S.; Valente-Feliciano, A.-M.; Phillips, L.; Vušković, L.

    2016-05-01

    An apparatus and a method are described for plasma etching of the inner surface of superconducting radio frequency (SRF) cavities. Accelerator SRF cavities are formed into a variable-diameter cylindrical structure made of bulk niobium, for resonant generation of the particle accelerating field. The etch rate non-uniformity due to depletion of the radicals has been overcome by the simultaneous movement of the gas flow inlet and the inner electrode. An effective shape of the inner electrode to reduce the plasma asymmetry for the coaxial cylindrical rf plasma reactor is determined and implemented in the cavity processing method. The processing was accomplished by moving axially the inner electrode and the gas flow inlet in a step-wise way to establish segmented plasma columns. The test structure was a pillbox cavity made of steel of similar dimension to the standard SRF cavity. This was adopted to experimentally verify the plasma surface reaction on cylindrical structures with variable diameter using the segmented plasma generation approach. The pill box cavity is filled with niobium ring- and disk-type samples and the etch rate of these samples was measured.

  3. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  4. Cuspal Deflection of Premolars Restored with Bulk-Fill Composite Resins.

    Science.gov (United States)

    Behery, Haytham; El-Mowafy, Omar; El-Badrawy, Wafa; Saleh, Belal; Nabih, Sameh

    2016-01-01

    This in vitro study compared cuspal deflection of premolars restored with three bulk-fill composite resins to that of incrementally-restored ones with a low-shrinkage silorane-based restorative material. Forty freshly-extracted intact human upper premolars were used. Reference points at buccal and palatal cusp tips were acid-etched and composite rods were horizontally bonded to them (TPH-Spectra-HV, Dentsply). Two acrylic resin guiding paths were made for each premolar to guide beaks of a digital micrometer used for cuspal deflection measurements. Standardized MOD cavities, 3 mm wide bucco-lingually and 3.5 mm deep, were prepared on each premolar. Prepared teeth were then equally divided into four groups (n = 10) and each group was assigned to one of four composite resin (QuiXX, Dentsply; X-tra fil, Voco; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; low-shrinkage Filtek LS, 3M/ESPE). Adper Single Bond-Plus, 3M/ESPE was used with all bulk-fill restoratives. LS-System Adhesive, 3M/ESPE was used with Filtek LS. For each prepared premolar, cuspal deflection was measured in microns as the difference between two readings between reference points before and after restoration completion. Means and SDs were calculated and data statistically-analyzed using One-way ANOVA and Tukey's test. Filtek LS showed the lowest mean cuspal deflection value 6.4(0.84)μm followed by Tetric EvoCeram Bulk Fill 10.1(1.2) μm and X-tra fil 12.4(1.35)μm, while QuiXX showed the highest mean 13(1.05)μm. ANOVA indicated significant difference among mean values of groups (p composite resins tested. Filtek LS had the lowest significant mean cuspal deflection in comparison to all tested bulk-fill restoratives. The use of Tetric EvoCeram Bulk fill composite resin restorative for class II MOD cavities resulted in reduced cuspal deflection in comparison to the two other bulk-fill composite resins tested. The silorane-based Filtek LS restorative resulted in the least cuspal deflection in

  5. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory

    Science.gov (United States)

    Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe’s coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer’s performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1, ω2) and the individual quality factors (Q1, Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, I/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be

  6. Effects of heater location and heater size on the natural convection heat transfer in a square cavity using finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Ngo, Ich Long; Byon, Chan [Yeungnam University, Gyeongsan (Korea, Republic of)

    2015-07-15

    Finite element method was used to investigate the effects of heater location and heater size on the natural convection heat transfer in a 2D square cavity heated partially or fully from below and cooled from above. Rayleigh number (5 X 10{sup 2} ≤ Ra ≤ 5X10{sup 5}), heater size (0.1 ≤ D/L ≤ 1.0), and heater location (0.1 ≤ x{sub h}/L ≤ 0.5) were considered. Numerical results indicated that the average Nusselt number (Nu{sub m}) increases as the heater size decreases. In addition, when x{sub h}/L is less than 0.4, Nu{sub m} increases as x{sub h}/L increases, and Num decreases again for a larger value of x{sub h}/L. However, this trend changes when Ra is less than 10{sup 4}, suggesting that Nu{sub m} attains its maximum value at the region close to the bottom surface center. This study aims to gain insight into the behaviors of natural convection in order to potentially improve internal natural convection heat transfer.

  7. Numerical model for the solution of two-dimensional natural convection problems in arbitrary cavities

    International Nuclear Information System (INIS)

    Milioli, F.E.

    1985-01-01

    In this research work a numerical model for the solution of two-dimensional natural convection problems in arbitrary cavities of a Boussinesq fluid is presented. The conservation equations are written in a general curvilinear coordinate system which matches the irregular boundaries of the domain. The nonorthogonal system is generated by a suitable system of elliptic equations. The momentum and continuity equations are transformed from the Cartesian system to the general curvilinear system keeping the Cartesian velocity components as the dependent variables in the transformed domain. Finite difference equations are obtained for the contravariant velocity components in the transformed domain. The numerical calculations are performed in a fixed rectangular domain and both the Cartesian and the contravariant velocity components take part in the solutiomn procedure. The dependent variables are arranged on the grid in a staggered manner. The numerical model is tested by solving the driven flow in a square cavity with a moving side using a nonorthogoanl grid. The natural convenction in a square cavity, using an orthogonal and a nonorthogonal grid, is also solved for the model test. Also, the solution for the buoyancy flow between a square cylinder placed inside a circular cylinder is presented. The results of the test problems are compared with those available in the specialized literature. Finally, in order to show the generality of the model, the natural convection problem inside a very irregular cavity is presented. (Author) [pt

  8. Numerical Investigation of Mixing Characteristics in Cavity Flow at Various Aspect Ratios

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Myung Seob [Dongyang Mirae University, Seoul (Korea, Republic of); Yang, Seung Deok; Yoon, Joon Yong [Hanyang University, Seoul (Korea, Republic of)

    2015-01-15

    This study numerically examined the mixing characteristics of rectangular cavity flows by using the hybrid lattice Boltzmann method (HLBM) applied to the finite difference method (FDM). Multi-relaxation time was used along with a passive scalar method which assumes that two substances have the same mass and that there is no interaction. First, we studied numerical results such as the stream function, position of vortices, and velocity profile for a square cavity and rectangular cavity with an aspect ratio of 2. The data were compared with previous numerical results that have been proven to be reliable. We also studied the mixing characteristics of a rectangular cavity flow such as the concentration profile and average Sherwood number at various Pe numbers and aspect ratios.

  9. Ultrasonically determined fill pressure and density in closed spherical shells

    International Nuclear Information System (INIS)

    Asaki, T.J.

    1998-01-01

    Experiments have been conducted in which the D 2 fill pressure has been determined for several closed millimeter-size aluminum and beryllium shells. The vibrational resonance frequency spectrum of the shells was used to calculate the sound velocity of the interior gas. This velocity, along with the equation-of-state, determined the gas pressure and density. The accuracy in determining the fill conditions is within 0.5% in both pressure and density for near critical density (ρ approx-gt 9 mol/L) gas over a wide range of temperatures (190 K to 300 K). Reduced accuracy was apparent at low density. An attempt was made to determine the fill density of one shell by acoustic observation of the dew point temperature. While this temperature was recorded very accurately, the uncertainty in the saturated vapor density curve near the critical point yielded inaccurate results. These methods were shown to be unaffected by small deviations in the sphericity of the gas-filled cavity

  10. Randomized 3-year Clinical Evaluation of Class I and II Posterior Resin Restorations Placed with a Bulk-fill Resin Composite and a One-step Self-etching Adhesive

    DEFF Research Database (Denmark)

    van Dijken, Jan Wv; Pallesen, Ulla

    2015-01-01

    PURPOSE: To evaluate the 3-year clinical durability of the flowable bulk-fill resin composite SDR in Class I and Class II restorations. MATERIALS AND METHODS: Thirty-eight pairs of Class I and 62 pairs of Class II restorations were placed in 44 male and 42 female patients (mean age 52.4 years......). Each patient received at least two extended Class I or Class II restorations that were as similar as possible. In all cavities, a one-step self-etching adhesive (XenoV+) was applied. One of the cavities of each pair was randomly assigned to receive the flowable bulk-fill resin composite SDR...... in increments up to 4 mm as needed to fill the cavity 2 mm short of the occlusal cavosurface. The occlusal part was completed with an ormocer-based nanohybrid resin composite (Ceram X mono+). In the other cavity, only the resin composite CeramX mono+ was placed in 2 mm increments. The restorations were...

  11. Impact of polymer film thickness and cavity size on polymer flow during embossing : towards process design rules for nanoimprint lithography.

    Energy Technology Data Exchange (ETDEWEB)

    Schunk, Peter Randall; King, William P. (Georgia Institute of Technology, Atlanta, GA); Sun, Amy Cha-Tien; Rowland, Harry D. (Georgia Institute of Technology, Atlanta, GA)

    2006-08-01

    This paper presents continuum simulations of polymer flow during nanoimprint lithography (NIL). The simulations capture the underlying physics of polymer flow from the nanometer to millimeter length scale and examine geometry and thermophysical process quantities affecting cavity filling. Variations in embossing tool geometry and polymer film thickness during viscous flow distinguish different flow driving mechanisms. Three parameters can predict polymer deformation mode: cavity width to polymer thickness ratio, polymer supply ratio, and Capillary number. The ratio of cavity width to initial polymer film thickness determines vertically or laterally dominant deformation. The ratio of indenter width to residual film thickness measures polymer supply beneath the indenter which determines Stokes or squeeze flow. The local geometry ratios can predict a fill time based on laminar flow between plates, Stokes flow, or squeeze flow. Characteristic NIL capillary number based on geometry-dependent fill time distinguishes between capillary or viscous driven flows. The three parameters predict filling modes observed in published studies of NIL deformation over nanometer to millimeter length scales. The work seeks to establish process design rules for NIL and to provide tools for the rational design of NIL master templates, resist polymers, and process parameters.

  12. Thermal non-equilibrium heat transfer in a porous cavity in the presence of bio-chemical heat source

    Directory of Open Access Journals (Sweden)

    Nazari Mohsen

    2015-01-01

    Full Text Available This paper is concerned with thermal non-equilibrium natural convection in a square cavity filled with a porous medium in the presence of a biomass which is transported in the cavity. The biomass can consume a secondary moving substrate. The physics of the presented problem is related to the analysis of heat and mass transfer in a composting process that controlled by internal heat generation. The intensity of the bio-heat source generated in the cavity is equal to the rate of consumption of the substrate by the biomass. It is assumed that the porous medium is homogeneous and isotropic. A two-field model that represents the fluid and solid phase temperature fields separately is used for energy equation. A simplified Monod model is introduced along with the governing equations to describe the consumption of the substrate by the biomass. In other word, the transient biochemical heat source which is dependent on a solute concentration is considered in the energy equations. Investigation of the biomass activity and bio-chemical heat generation in the case of thermal non-equilibrium assumption has not been considered in the literature and they are open research topics. The effects of thermal non-equilibrium model on heat transfer, flow pattern and biomass transfer are investigated. The effective parameters which have a direct impact on the generated bio-chemical heat source are also presented. The influences of the non-dimensional parameters such as fluid-to-solid conductivity ratio on the temperature distribution are presented.

  13. Influence of radiation on double conjugate diffusion in a porous cavity

    International Nuclear Information System (INIS)

    Azeem,; Idris, Mohd Yamani Idna; Khan, T. M. Yunus; Badruddin, Irfan Anjum; Nik-Ghazali, N.

    2016-01-01

    The current work highlights the effect of radiation on the conjugate heat and mass transfer in a square porous cavity having a solid wall. The solid wall is placed at the center of cavity. The left surface of cavity is maintained at higher temperature T_w and concentration C_w whereas the right surface is maintained at T_c and C_c such that T_w>T_c and Cw>Cc. The top and bottom surfaces are adiabatic. The governing equations are solved with the help of finite element method by making use of triangular elements. The results are discussed with respect to two different heights of solid wall inside the porous medium along with the radiation parameter.

  14. Radioisotopes in the study of the adaptation of dental amalgam fillings

    International Nuclear Information System (INIS)

    Bermawi, A.

    1995-02-01

    Adaptation expresses the significance of the relationship between the dental filling and its cavity, and forms a special challenge for the dentist when he performs dental restorative procedures. Therefore, I have done a study on the adaptation of dental amalgam fillings and their marginal leakage using radioactive iodine (I sup 1 sup 3 sup 1) and radioactive carbon (C sup 1 sup 4) on three alloys: Viva cap-Contour-Sybraloy. Marginal leakage has been established by the use of I sup 1 sup 3 sup 1, and the leakage points located by C sup 1 sup 4, by means of radioautography. This study was carried out on: - 45 dental specimens to examine marginal leakage. - 9 dental specimens to examine the time of leakage as it reached the occlusal surface. - 6 dental specimens to examine the effect of lining the cavity walls with NO sup 3 Ag varnish on marginal leakage. - 5 dental specimens to examine the effect of form (bevel) of pulpal axial point angle on marginal leakage. - 3 dental specimens as controls. - 25 dental specimens for radioautography, and to determine leakage points. The following results were observed: - Leakage occurred around the contours of all fillings under study, and spread from their basal parts to the angle of their occlusal margin. - Quantitative increase of leakage with time. - The type of the alloy played an active role in determining the pattern of leakage. - Metallic amalgam alloys with spheroidal regular atoms showed the least leakage. - The occlusal sulci exhibited more leakage than the other parts. - Beveling the pulpal axial point angle decreased leakage. - Lining the cavity walls with NO sup 3 Ag varnish inhibited leakage. - The radioactive element, to which the specimens were exposed, was unable to infiltrated and penetrate dentinal and enamel tissues. (author). 55 refs, 52 figs., 68 tabs

  15. Radioisotopes in the study of the adaptation of dental amalgam fillings

    Energy Technology Data Exchange (ETDEWEB)

    Bermawi, A [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Protection and Nuclear Safety

    1995-02-01

    Adaptation expresses the significance of the relationship between the dental filling and its cavity, and forms a special challenge for the dentist when he performs dental restorative procedures. Therefore, I have done a study on the adaptation of dental amalgam fillings and their marginal leakage using radioactive iodine (I sup 1 sup 3 sup 1) and radioactive carbon (C sup 1 sup 4) on three alloys: Viva cap-Contour-Sybraloy. Marginal leakage has been established by the use of I sup 1 sup 3 sup 1, and the leakage points located by C sup 1 sup 4, by means of radioautography. This study was carried out on: - 45 dental specimens to examine marginal leakage. - 9 dental specimens to examine the time of leakage as it reached the occlusal surface. - 6 dental specimens to examine the effect of lining the cavity walls with NO sup 3 Ag varnish on marginal leakage. - 5 dental specimens to examine the effect of form (bevel) of pulpal axial point angle on marginal leakage. - 3 dental specimens as controls. - 25 dental specimens for radioautography, and to determine leakage points. The following results were observed: - Leakage occurred around the contours of all fillings under study, and spread from their basal parts to the angle of their occlusal margin. - Quantitative increase of leakage with time. - The type of the alloy played an active role in determining the pattern of leakage. - Metallic amalgam alloys with spheroidal regular atoms showed the least leakage. - The occlusal sulci exhibited more leakage than the other parts. - Beveling the pulpal axial point angle decreased leakage. - Lining the cavity walls with NO sup 3 Ag varnish inhibited leakage. - The radioactive element, to which the specimens were exposed, was unable to infiltrated and penetrate dentinal and enamel tissues. (author). 55 refs, 52 figs., 68 tabs.

  16. Atraumatic restorative treatment in atypical cavities

    Directory of Open Access Journals (Sweden)

    Letícia Simino Carvalho

    2009-10-01

    Full Text Available The atraumatic restorative treatment has been widely divulged among professionals in the area of Pediatric Dentistry. This restorative technique is included in the philosophy of Minimal Intervention and is considered one of the most conservative treatments, because only the layer of infected dentin caries is removed. Moreover, the atraumatic restorative treatment has been shown to be less painful than conventional approaches, and local anesthesia is rarely required. After the removal of the infected dentin, the cavities are filled with glass ionomer cement, a material that has antimicrobial capacity, good marginal sealing and constant fluorine release and recharge. In spite of the increasing number of studies about atraumatic restorative treatment, only studies related to restorations in occlusal cavities have shown scientific evidences about the technique. The aim of this study was to evaluate the feasibility of atraumatic restorative treatment in cavities with 3 or more surfaces involved, by means of a clinical case report of a patient with extensive dstruction in primary teeth, who was submitted to atraumatic restorative treatment, and observe the result of the treatment after one year of clinical and radiographic control.

  17. Hydroxyapatite granules used in the obliteration of mastoid cavities in rats.

    Science.gov (United States)

    Hamerschmidt, Rogério; Santos, Rafael Francisco dos; Araújo, João Cândido; Stahlke, Henrique Jorge; Agulham, Miguel Angelo; Moreira, Ana Tereza Ramos; Mocellin, Marcos

    2011-06-01

    Prospective experimental study in which we created a bony defect in the mastoids of rats and filled it up with hydroxyapatite to evaluate bone regeneration, to solve the problems of open cavities after mastoidectomies that frequently present with otorrhea, infection, granulation tissue and hearing loss. The aim was to evaluate bone regeneration in defects created in the mastoids of rats, using hydroxyapatite, to see how much of the cavity we could reduce. Twelve rats Wistar-Furth were used. A 0.5 x 0.5 cm bone defect was created in both temporal bones of the rats, and filled with 15 micrograms of hydroxyapatite. The left side was used as control. The animals were slaughtered 40 days afterwards and histology analyses were carried out. In the hydroxyapatite group, the new bone growth involved an area of 68.53% of the total; and in the control group it was only of 15.97%. It was observed a very good hydroxyapatite integration to the temporal bone in this experimental model. The microscopic results were superior with the use of hydroxyapatite when compared to the control group. It is a safe method and easy to apply to solve the problems of open cavities with chronic discharge and difficult to clean.

  18. Design of 118 MHz twelfth harmonic cavity of APS PAR

    International Nuclear Information System (INIS)

    Kang, Y.W.; Kustom, R.L.; Bridges, J.F.

    1992-01-01

    Two radio frequency (RF) cavities are needed in the Positron Accumulator Ring (PAR) of the Advanced Photon Source. One is for the first harmonic frequency at 9.8 MHz, and the other is for the twelfth harmonic frequency at 118 MHz. This note reports on the design of the 118 MHz RF cavity. Computer models are used to find the mode frequencies, impedances, Q-factors, and field distributions in the cavity. The computer codes MAFIA, URMEL, and URMEL-T are useful tools which model and simulate the resonance characteristics of a cavity. These codes employ the finite difference method to solve Maxwell's equations. MAFIA is a three-dimensional problem solver and uses square patches to approximate the inner surface of a cavity. URMEL and URMEL-T are two-dimensional problem solvers and use rectangular and triangular meshes, respectively. URMEL-T and MAFIA can handle problems with arbitrary dielectric materials located inside the boundary. The cavity employs a circularly cylindrical ceramic window to limit the vacuum to the beam pipe. The ceramic window used in the modeling will have a wall thickness of 0.9 cm. This wall thickness is not negligible in determining the resonant frequencies of the cavity. In the following, results of two- and three-dimensional modeling of the cavities using the URMEL-T and MAFIA codes are reported

  19. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory.

    Science.gov (United States)

    Elnaggar, Sameh Y; Tervo, Richard; Mattar, Saba M

    2014-05-01

    A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe's coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer's performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1,ω2) and the individual quality factors (Q1,Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, Iwithinsert/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be

  20. Transport rates and concentration gradients during grain filling in wheat

    International Nuclear Information System (INIS)

    Fisher, D.B.; Gifford, R.M.

    1986-01-01

    Short-term mass transport rates into wheat ears were calculated at mid grain fill from 32 PO 4 translocation velocities and sieve tube sap concentrations in the peduncle. Over a wide range of velocities (8.5 to 170 cm/hr), sieve tube sap concentrations (514 to 1050 milliosmolal) and grains per ear (20 to 54 in intact ears, as few as 7 in partially degrained ears), there were no evident differences in the rate of mass transport per grain through the peduncle. Increased sieve tube sap concentration was accompanied in the endosperm cavity sap by increased sucrose concentration, but amino acid concentration and total osmolality remained essentially constant. Thus the rate of transport into the grains appeared to remain constant in spite of altered concentration gradients across the crease tissues of the grain and changing sucrose concentration in the endosperm cavity. The constancy of endosperm cavity sap osmolality suggests that osmoregulatory processes in the grain may play a role in regulating transport rate into the grain

  1. The quest for high-gradient superconducting cavities

    International Nuclear Information System (INIS)

    Padamsee, H.

    1999-01-01

    Superconducting RF cavities excel in applications requiring continuous waves or long pulse voltages. Since power losses in the walls of the cavity increase as the square of the accelerating voltage, copper cavities become uneconomical as demand for high continuous wave voltage grows with particle energy. For these reasons, RF superconductivity has become an important technology for high energy and high luminosity accelerators. The state of art in performance of sheet metal niobium cavities is best represented by the statistics of more than 300 5-cell, 1.5-GHz cavities built for CEBAF. Key aspects responsible for the outstanding performance of the CEBAF cavities set are the anti-multipactor, elliptical cell shape, good fabrication and welding techniques, high thermal conductivity niobium, and clean surface preparation. On average, field emission starts at the electric field of 8.7 MV/m, but there is a large spread, even though the cavities received nominally the same surface treatment and assembly procedures. In some cavities, field emission was detected as low as 3 MV/m. In others, it was found to be as high as 19 MV/m. As we will discuss, the reason for the large spread in the gradients is the large spread in emitter characteristics and the random occurrence of emitters on the surface. One important phenomenon that limits the achievable RF magnetic field is thermal breakdown of superconductivity, originating at sub-millimeter-size regions of high RF loss, called defects. Simulation reveal that if the defect is a normal conducting region of 200 mm radius, it will break down at 5 MV/m. Producing high gradients and high Q in superconducting cavities demands excellent control of material properties and surface cleanliness. The spread in gradients that arises from the random occurrence of defects and emitters must be reduced. It will be important to improve installation procedures to preserve the excellent gradients now obtained in laboratory test in vertical cryostats

  2. Influence of radiation on double conjugate diffusion in a porous cavity

    Energy Technology Data Exchange (ETDEWEB)

    Azeem,; Idris, Mohd Yamani Idna [Dept. of Computer System & Technology, University of Malaya, Kuala Lumpur (Malaysia); Khan, T. M. Yunus, E-mail: yunus.tatagar@gmail.com [Dept. of Mechanical Engineering, University of Malaya, Kuala Lumpur, 50603 (Malaysia); Dept. of Mechanical Engineering, BVB College of Engineering & Technology, Hubli (India); Badruddin, Irfan Anjum, E-mail: irfan-magami@Rediffmail.com; Nik-Ghazali, N. [Dept. of Mechanical Engineering, University of Malaya, Kuala Lumpur, 50603 (Malaysia)

    2016-05-06

    The current work highlights the effect of radiation on the conjugate heat and mass transfer in a square porous cavity having a solid wall. The solid wall is placed at the center of cavity. The left surface of cavity is maintained at higher temperature T{sub w} and concentration C{sub w} whereas the right surface is maintained at T{sub c} and C{sub c} such that T{sub w}>T{sub c} and Cw>Cc. The top and bottom surfaces are adiabatic. The governing equations are solved with the help of finite element method by making use of triangular elements. The results are discussed with respect to two different heights of solid wall inside the porous medium along with the radiation parameter.

  3. Polymer deformation and filling modes during microembossing

    Science.gov (United States)

    Rowland, Harry D.; King, William P.

    2004-12-01

    This work investigates the initial stages of polymer deformation during hot embossing micro-manufacturing at processing temperatures near the glass transition temperature (Tg) of polymer films having sufficient thickness such that polymer flow is not supply limited. Several stages of polymer flow can be observed by employing stamp geometries of various widths and varying imprint conditions of time and temperature to modulate polymer viscosity. Experiments investigate conditions affecting cavity filling phenomena, including apparent polymer viscosity. Stamps with periodic ridges of height and width 4 µm and periodicity 30, 50 and 100 µm emboss trenches into polymethyl methacrylate films at Tg - 10 °C time, temperature and load are correlated with replicated polymer shape, height and imprinted area. Polymer replicates are measured by atomic force microscopy and inspected by scanning electron microscopy. Cavity size and the temperature dependence of polymer viscosity significantly influence the nature of polymer deformation in hot embossing micro-manufacturing and must be accounted for in rational process design.

  4. Application of isotope tracer technique on the study of the filling and release behavior of carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Shengwei; Guo Jinxue; Li Yan; Li Yulan; Li Wenxin; Liu Shiyuan

    2004-01-01

    The behaviors of washing and release of 110 Ag m -AgNO 3 from carbon nanotubes (CNTs), following soak of opened CNTs in 110 Ag m -AgNO 3 solutions are investigated with the isotope tracer technique. The filled CNTs samples are characterized by HREM, SEM, XRD and EDS. The amount of filled materials is also estimated by the isotope tracer technique. It shows that there are silver materials filled in the CNTs and would not release from the cavities. The results indicate that radioactive tracer is an effective and powerful technique to be applied into study of filling and release behaviors of CNTs as well as estimating the amount of filled materials. (authors)

  5. Heat transfer prediction in a square porous medium using artificial neural network

    Science.gov (United States)

    Ahamad, N. Ameer; Athani, Abdulgaphur; Badruddin, Irfan Anjum

    2018-05-01

    Heat transfer in porous media has been investigated extensively because of its applications in various important fields. Neural network approach is applied to analyze steady two dimensional free convection flows through a porous medium fixed in a square cavity. The backpropagation neural network is trained and used to predict the heat transfer. The results are compared with available information in the literature. It is found that the heat transfer increases with increase in Rayleigh number. It is further found that the local Nusselt number decreases along the height of cavity. The neural network is found to predict the heat transfer behavior accurately for given parameters.

  6. Contact mechanics for poroelastic, fluid-filled media, with application to cartilage.

    Science.gov (United States)

    Persson, B N J

    2016-12-21

    I study a simple contact mechanics model for a poroelastic, fluid-filled solid squeezed against a rigid, randomly rough substrate. I study how the fluid is squeezed out from the interface, and how the area of contact, and the average interfacial separation, change with time. I present numerical results relevant for a human cartilage. I show that for a fluid filled poroelastic solid the probability of cavitation (and the related wear as the cavities implode), and dynamical scraping (defined below and in Hutt and Persson, J. Chem. Phys. 144, 124903 (2016)), may be suppressed by fluid flow from the poroelastic solid into the (roughness induced) interfacial gap between the solids.

  7. Square pulse linear transformer driver

    Directory of Open Access Journals (Sweden)

    A. A. Kim

    2012-04-01

    Full Text Available The linear transformer driver (LTD technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  8. R & D of a Gas-Filled RF Beam Profile Monitor for Intense Neutrino Beam Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yonehara, K. [Fermilab; Backfish, M. [Fermilab; Moretti, A. [Fermilab; Tollestrup, A. V. [Fermilab; Watts, A. [Fermilab; Zwaska, R. M. [Fermilab; Abrams, R. [MUONS Inc., Batavia; Cummings, M. A.; Dudas, A. [MUONS Inc., Batavia; Johnson, R. P. [MUONS Inc., Batavia; Kazakevich, G. [MUONS Inc., Batavia; Neubauer, M. [MUONS Inc., Batavia; Liu, Q. [Case Western Reserve U.

    2017-05-01

    We report the R&D of a novel radiation-robust hadron beam profile monitor based on a gas-filled RF cavity for intense neutrino beam experiments. An equivalent RF circuit model was made and simulated to optimize the RF parameter in a wide beam intensity range. As a result, the maximum acceptable beam intensity in the monitor is significantly increased by using a low-quality factor RF cavity. The plan for the demonstration test is set up to prepare for future neutrino beam experiments.

  9. High Pressure, High Gradient RF Cavities for Muon Beam Cooling

    CERN Document Server

    Johnson, R P

    2004-01-01

    High intensity, low emittance muon beams are needed for new applications such as muon colliders and neutrino factories based on muon storage rings. Ionization cooling, where muon energy is lost in a low-Z absorber and only the longitudinal component is regenerated using RF cavities, is presently the only known cooling technique that is fast enough to be effective in the short muon lifetime. RF cavities filled with high-pressure hydrogen gas bring two advantages to the ionization technique: the energy absorption and energy regeneration happen simultaneously rather than sequentially, and higher RF gradients and better cavity breakdown behavior are possible than in vacuum due to the Paschen effect. These advantages and some disadvantages and risks will be discussed along with a description of the present and desired RF R&D efforts needed to make accelerators and colliders based on muon beams less futuristic.

  10. Effect of fiber inserts on gingival margin microleakage of Class II bulk-fill composite resin restorations.

    Science.gov (United States)

    Shafiei, Fereshteh; Doozandeh, Maryam; Karimi, Vahid

    2018-01-01

    This study evaluated the effect of fiber inserts combined with composite resins on enamel and dentin margin microleakage. The fiber inserts were used with high- (x-tra fil) and low-viscosity (x-tra base) bulk-fill composite resins and as well as conventional composite resins (Grandio and Grandio Flow). In 96 sound, recently extracted molars, 2 standardized Class II cavities were prepared. The teeth were randomly divided into 8 groups of 12 teeth each, based on composite resin type and presence or absence of fiber inserts: groups 1 and 2, x-tra fil with and without fiber inserts, respectively; groups 3 and 4, x-tra base with and without fiber inserts; groups 5 and 6, Grandio with and without fiber inserts; and groups 7 and 8, Grandio Flow liner (gingival floor)/Grandio (remainder of cavity) with and without fiber inserts. In all the groups, a 2-step etch-and-rinse adhesive was used. The specimens were processed in a dye penetration technique to determine microleakage percentages. Data were analyzed with analysis of variance, Tukey, and t tests. There was significantly less leakage at the enamel margins than the dentin margins. Fiber reinforcement significantly decreased enamel microleakage in all the groups, with no significant differences among the groups. Concerning dentin microleakage, there were no significant differences among the 4 groups without fiber inserts, while a significant difference was detected in groups 2 (x-tra fil plus fiber) and 8 (Grandio Flow plus fiber/Grandio). Fibers significantly improved dentin sealing in groups 2 and 8. These findings suggest that a fiber insert reinforcing bulk-fill and conventional composite resins might improve enamel sealing in shallow Class II cavi-ties. The effect of fiber reinforcement on the dentin margins of deep cavities depended on the viscosity of the composite resins; fiber reinforcement was effective for flowable bulk-fill and conventional composite resin restorations.

  11. Dental plaque as a biofilm - a risk in oral cavity and methods to prevent

    OpenAIRE

    Renata Chałas; Ilona Wójcik-Chęcińska; Michał J. Woźniak; Justyna Grzonka; Wojciech Święszkowski; Krzysztof J. Kurzydłowski

    2015-01-01

    Bacteria living constantly in the oral cavity are in the form of a biofilm. The biofilm formed on a solid base such as the enamel of the teeth, fillings, restorations, orthodontic appliances or obturators is dental plaque. Disturbance of homeostasis of biofilm, excessive growth or increase in the number of acid-forming bacteria leads to the development of the most common diseases of the oral cavity, i.e. dental caries and periodontal disease. The presence of bacterial biofilm on the walls of ...

  12. A new approach for the validation of filling simulations in micro injection moulding

    DEFF Research Database (Denmark)

    Gava, Alberto; Tosello, Guido; Lucchetta, Giovanni

    2007-01-01

    to be improved. The main objective of this work is to evaluate whether the present numerical codes are suitable to characterize melt flow patterns in a micro cavity. In order to test the accuracy of the software, real and simulated experiments were performed and used to investigate the filling of a micro moulded...

  13. Inkjet printing as a technique for filling of micro-wells with biocompatible polymers

    DEFF Research Database (Denmark)

    Marizza, Paolo; Keller, Stephan Sylvest; Boisen, Anja

    2013-01-01

    We present an innovative technique to dispense precise amounts of polymer solutions into large arrays of microscopic wells. An inkjet printer (NP 2.1 GeSim, Germany) is used to fill micro-wells with poly (vinyl pyrrolidone) (PVP K10). The micro-wells are fabricated with cavity diameters of 300 μm...

  14. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    International Nuclear Information System (INIS)

    Dall'agnol, Cristina; Barletta, Fernando Branco; Hartmann, Mateus Silveira Martins

    2008-01-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend (α=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  15. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    Energy Technology Data Exchange (ETDEWEB)

    Dall' agnol, Cristina; Barletta, Fernando Branco [Lutheran University of Brazil, Canoas, RS (Brazil). Dental School. Dept. of Dentistry and Endodontics]. E-mail: fbarletta@terra.com.br; Hartmann, Mateus Silveira Martins [Uninga Dental School, Passo Fundo, RS (Brazil). Postgraduate Program in Dentistry

    2008-07-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend ({alpha}=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  16. Study of microwave instabilities by means of a square-well potential

    International Nuclear Information System (INIS)

    Kim, K.J.

    1979-01-01

    Microwave instabilities are analyzed in a simple model, in which the usual synchrotron oscillation of a particle is replaced by particle motion in a square-well potential. In the usual synchrotron oscillation, a particle moves along an elliptic trajectory. The most natural coordinates for such a motion are the action and the angle variables. On the other hand, the distribution of the particles along the ring is most conveniently described by azimuthal variables. The difficulty disappears if the synchrotron motion is approximated by the motion in a square-well potential. The square-well potential may seem extremely unphysical. However, it should be remarked that the form of the potential with addition of a Landau cavity looks more or less like a square-well. At any rate, the main motivation of introducing the square-well here is to simplify the mathematics of and thereby gain some insight into microwave instabilities. The model is exactly soluble. The results are in general agreement with the conclusions obtained from qualitative arguments based on coasting beam theory. However, some of the detailed features of the solution, for example the behavior of ω 2 as a function of impedance, are surprising

  17. A free-jet experimental study on the performance of a cavity-type ramjet

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jianguo; Pan, Yu; Liang, Jianhan; Wang, Zhenguo [National University of Defense Technology, ChangSha (China)

    2011-11-15

    Free jet experiments have been conducted to evaluate the performance of a cavity-type ramjet. To prevent uncertainty of combustion parameters, a method to calculate internal thrust from cold flow parameters is brought forward. According to this analysis method, the internal thrust of the cavity-type ramjet increases linearly with the stoichiometric ratio while the specific impulse decreases squarely. The aero-propulsive balance of a conceptive missile is also examined, focusing on the effect of attack angle. Considering both efficiency and performance, an attack angle of 3{approx}6 degrees is recommended. And the free-jet experimental results show that the cavity-type ramjet can supply sufficient thrust for the missile under cruise conditions.

  18. Dynamics of atom-field probability amplitudes in a coupled cavity system with Kerr non-linearity

    Energy Technology Data Exchange (ETDEWEB)

    Priyesh, K. V.; Thayyullathil, Ramesh Babu [Department of Physics, Cochin University of Science and Technology, Cochin (India)

    2014-01-28

    We have investigated the dynamics of two cavities coupled together via photon hopping, filled with Kerr non-linear medium and each containing a two level atom in it. The evolution of various atom (field) state probabilities of the coupled cavity system in two excitation sub space are obtained numerically. Detailed analysis has been done by taking different initial conditions of the system, with various coupling strengths and by varying the susceptibility of the medium. The role of susceptibility factor, on the dynamics atom field probability has been examined. In a coupled cavity system with strong photon hopping it is found that the susceptibility factor modifies the behaviour of probability amplitudes.

  19. Radiographic evaluation of root canal fillings accomplished by undergraduate dental students.

    Science.gov (United States)

    Yavari, Hamidreza; Samiei, Mohammad; Shahi, Shahriar; Borna, Zahra; Abdollahi, Amir Ardalan; Ghiasvand, Negar; Shariati, Gholamreza

    2015-01-01

    The purpose of this study was to evaluate the radiographic quality of root canal fillings by fourth-, fifth-, and sixth-year undergraduate students at Tabriz Faculty of Dentistry between 2006 and 2012. A total of 1183 root canal fillings in 620 teeth were evaluated by two investigators (and in case of disagreement by a third investigator) regarding the presence or absence of under-fillings, over-fillings and perforations. For each tooth, preoperative, working and postoperative radiographs were checked. The Pearson's chi-square test was used for statistical evaluation of the data. Inter-examiner agreement was measured by Cohen's kappa (k) values. The level of significance was set at 0.05. Total frequencies of over-filling, under-filling and perforation were 5.6%, 20.4% and 1.9%, respectively. There were significant differences between frequencies of over- and under-fillings (P<0.05). Unacceptable quality, under- and over-fillings were detected in 27.9% of 1183 evaluated canals. The technical quality of root canal therapies performed by undergraduate dental students using step-back preparation and lateral compaction techniques was unacceptable in almost one-fourth of the cases.

  20. Characteristics of novel root-end filling material using epoxy resin and Portland cement.

    Science.gov (United States)

    Lee, Sang-Jin; Chung, Jin; Na, Hee-Sam; Park, Eun-Joo; Jeon, Hyo-Jin; Kim, Hyeon-Cheol

    2013-04-01

    The aim of this study was to evaluate the physical properties and cytotoxicity of a novel root-end filling material (EPC) which is made from epoxy resin and Portland cement as a mineral trioxide aggregate (MTA) substitute. EPC, developed as a root-end filling material, was compared with MTA and a mixture of AH Plus sealer and MTA (AMTA) with regard to the setting time, radio-opacity, and microleakage. Setting times were evaluated using Vicat apparatus. Digital radiographs were taken to evaluate the aluminium equivalent radio-opacity using an aluminium step wedge. Extracted single-rooted teeth were used for leakage test using methylene blue dye. After canal shaping and obturation, the apical 3-mm root was resected, and a root-end cavity with a depth of 3 mm was prepared. The root-end cavities were filled with MTA, AMTA, and EPC for 15 specimens in each of three groups. After setting in humid conditions for 24 h, the specimens were tested for apical leakage. For evaluation of the biocompatibility of EPC, cell (human gingival fibroblast) viability was compared for MTA and Portland cement by MTT assay, and cell morphological changes were compared for MTA and AH Plus by fluorescence microscopy using DAPI and F-actin staining. The setting time, radio-opacity, and microleakage were compared using one-way ANOVA and Scheffe's post hoc comparison, and the cytotoxicity was compared using the nonparametric Kruskal-Wallis rank sum test. Statistical significance was set at 95%. EPC had a shorter setting time and less microleakage compared with MTA (p Portland cement, was found to be a useful material for root-end filling, with favourable radio-opacity, short setting time, low microleakage, and clinically acceptable low cytotoxicity. The novel root-end filling material would be a potentially useful material for a surgical endodontic procedure with favourable properties.

  1. The Experimental Study of Dynamics of Scaled Gas-Filled Bubble Collapse in Liquid

    Science.gov (United States)

    Pavlenko, Alexander

    2011-06-01

    The article provides results of analyzing special features of the single-bubble sonoluminescence, developing the special apparatus to investigate this phenomenon on a larger-scale basis. Certain very important effects of high energy density physics, i.e. liquid compressibility, shock-wave formation under the collapse of the gas cavity in liquid, shock-wave focusing in the gas-filled cavity, occurrence of hot dense plasma in the focusing area, and high-temperature radiation yield are observed in this phenomenon. Specificity of the process is conditioned by the ``ideal'' preparation and sphericity of the gas-and-liquid contact boundary what makes the collapse process efficient due to the reduced influence of hydrodynamic instabilities. Results of experimental investigations; results of developing the facilities, description of methods used to register parameters of facilities and the system under consideration; analytical estimates how gas-filled bubbles evolve in liquid with the regard for scale effects; results of preliminary 1-D gas dynamic calculations of the gas bubble evolution are presented. The work supported by ISTC Project #2116.

  2. Adiabatic partition effect on natural convection heat transfer inside a square cavity: experimental and numerical studies

    Science.gov (United States)

    Mahmoudinezhad, S.; Rezania, A.; Yousefi, T.; Shadloo, M. S.; Rosendahl, L. A.

    2018-02-01

    A steady state and two-dimensional laminar free convection heat transfer in a partitioned cavity with horizontal adiabatic and isothermal side walls is investigated using both experimental and numerical approaches. The experiments and numerical simulations are carried out using a Mach-Zehnder interferometer and a finite volume code, respectively. A horizontal and adiabatic partition, with angle of θ is adjusted such that it separates the cavity into two identical parts. Effects of this angel as well as Rayleigh number on the heat transfer from the side-heated walls are investigated in this study. The results are performed for the various Rayleigh numbers over the cavity side length, and partition angles ranging from 1.5 × 105 to 4.5 × 105, and 0° to 90°, respectively. The experimental verification of natural convective flow physics has been done by using FLUENT software. For a given adiabatic partition angle, the results show that the average Nusselt number and consequently the heat transfer enhance as the Rayleigh number increases. However, for a given Rayleigh number the maximum and the minimum heat transfer occurs at θ = 45°and θ = 90°, respectively. Two responsible mechanisms for this behavior, namely blockage ratio and partition orientation, are identified. These effects are explained by numerical velocity vectors and experimental temperatures contours. Based on the experimental data, a new correlation that fairly represents the average Nusselt number of the heated walls as functions of Rayleigh number and the angel of θ for the aforementioned ranges of data is proposed.

  3. ELMO Bumpy Square proposal

    International Nuclear Information System (INIS)

    Dory, R.A.; Uckan, N.A.; Ard, W.B.

    1986-10-01

    The ELMO Bumpy Square (EBS) concept consists of four straight magnetic mirror arrays linked by four high-field corner coils. Extensive calculations show that this configuration offers major improvements over the ELMO Bumpy Torus (EBT) in particle confinement, heating, transport, ring production, and stability. The components of the EBT device at Oak Ridge National Laboratory can be reconfigured into a square arrangement having straight sides composed of EBT coils, with new microwave cavities and high-field corners designed and built for this application. The elimination of neoclassical convection, identified as the dominant mechanism for the limited confinement in EBT, will give the EBS device substantially improved confinement and the flexibility to explore the concepts that produce this improvement. The primary goals of the EBS program are twofold: first, to improve the physics of confinement in toroidal systems by developing the concepts of plasma stabilization using the effects of energetic electrons and confinement optimization using magnetic field shaping and electrostatic potential control to limit particle drift, and second, to develop bumpy toroid devices as attractive candidates for fusion reactors. This report presents a brief review of the physics analyses that support the EBS concept, discussions of the design and expected performance of the EBS device, a description of the EBS experimental program, and a review of the reactor potential of bumpy toroid configurations. Detailed information is presented in the appendices

  4. Effect of two storage solutions on surface topography of two root-end fillings.

    Science.gov (United States)

    Asgary, Saeed; Eghbal, Mohammad Jafar; Parirokh, Masoud; Ghoddusi, Jamileh

    2009-12-01

    The effect of different storage solutions on surface topography of mineral trioxide aggregate (MTA) and new experimental cement (NEC) as root-end fillings was investigated. Twenty-four single-rooted teeth were cleaned, shaped and obturated in a same manner. After root-end resection, 3-mm deep root-end cavities were ultrasonically prepared. Samples were randomly divided into four test groups (A1-A2-B1-B2, n = 6). Root-end cavities in groups A and B were filled with MTA and NEC, respectively, and were then stored in 100% humidity for 24 h. The samples of groups 1 and 2 were, respectively, immersed in normal saline (NS) and phosphate buffer saline solutions for 1 week. The samples were imaged under stereomicroscope before and after immersion and were then investigated and analysed by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDXA). Results showed significant difference among studied groups. Surface topography of all samples was altered by crystal formation and precipitation on root-end fillings except for group A1 (MTA-NS). SEM and EDXA results showed that the composition and structure of precipitated crystals were comparable with that of standard hydroxyapatite. It was concluded that biocompatibility, sealing ability, and cementogenic activity of MTA and probably NEC may be attributed to this fundamental bioactive reaction.

  5. Plasmon resonant cavities in vertical nanowire arrays

    Science.gov (United States)

    Bora, Mihail; Bond, Tiziana C.; Fasenfest, Benjamin J.; Behymer, Elaine M.

    2014-07-15

    Tunable plasmon resonant cavity arrays in paired parallel nanowire waveguides are presented. Resonances can be observed when the waveguide length is an odd multiple of quarter plasmon wavelengths, consistent with boundary conditions of node and antinode at the ends. Two nanowire waveguides can satisfy the dispersion relation of a planar metal-dielectric-metal waveguide of equivalent width equal to the square field average weighted gap. Confinement factors of over 10.sup.3 are possible due to plasmon focusing in the inter-wire space.

  6. Thermographic analysis of the effect of composite type, layering method, and curing light on the temperature rise of photo-cured composites in tooth cavities.

    Science.gov (United States)

    Kim, Min-Jung; Kim, Ryan Jin-Young; Ferracane, Jack; Lee, In-Bog

    2017-10-01

    The purpose of this study was to investigate temperature rise in the composite and dentin of a class I cavity in extracted human molars under different restoration conditions, including the use of different composite types, layering methods, and curing lights. Open occlusal cavities were prepared on 28 extracted human molars. A conventional (Filtek Z250) and a bulk-fill (Filtek Bulk Fill Posterior; BFP) composite were used to restore the preparations. BFP was incrementally layered or bulk-filled. Bulk-filled BFP was cured with two different lights, the Elipar S10 and the BeLite. Each layer was illuminated for 20s, while thermograms of the specimens were recorded for 100s using an infrared thermal camera. Temperature changes on the composite and dentin surfaces were obtained at points of interest (POI) pertaining to successive incremental distances of 0.75mm from the top of the cavity to the pulp. The polymerization kinetics of each composite was determined using photo-differential scanning calorimetry. The greatest temperature rise was observed 0.75mm apical from the top of the cavity. All groups showed over 6°C maximum temperature rise (ΔT max ) at the pulpal side of the dentin. Upon curing, Z250 reached ΔT=5°C faster than BFP; however, ΔT max of the two composites were comparable at any POI. Bulk filling showed greater ΔT max than incremental filling at 0.75mm apical from the top and in the middle of the cavity. The Elipar S10 light generated faster temperature changes in the curing composite at all recorded positions throughout the depth of the cavity and greater ΔT max in all POIs compared to BeLite. Real-time thermographic analysis demonstrated that the composite type and layering method did not influence the temperature rise at the pulpal side of dentin during composite restoration of an occlusal preparation in a tooth. The amount and initial rate of temperature increase was most affected by the radiant exposure of the light curing unit. Within the

  7. Thermodynamic analysis of an organic rankine cycle using a tubular solar cavity receiver

    International Nuclear Information System (INIS)

    Loni, R.; Kasaeian, A.B.; Mahian, O.; Sahin, A.Z.

    2016-01-01

    Highlights: • A non-regenerative Organic Rankine Cycle has been analyzed. • R113, R601, R11, R141b, Ethanol and Methanol were used as the working fluid. • A parabolic dish concentrator with a square prismatic cavity receiver was used. • Thermal efficiency, second law efficiency, and net power output were analyzed. - Abstract: In this study, a non-regenerative Organic Rankine Cycle (ORC) has been thermodynamically analyzed under superheated conditions, constant evaporator pressure of 2.5 MPa, and condenser temperature of 300 K. R113, R601, R11, R141b, Ethanol and Methanol were employed as the working fluid. A parabolic dish concentrator with a square prismatic tubular cavity receiver was used as the heat source of the ORC system. The effects of the tube diameter, the cavity depth, and the solar irradiation on the thermodynamic performance of the selected working fluid were investigated. Some thermodynamic parameters were analyzed in this study. These thermodynamic parameters included the thermal efficiency, second law efficiency, total irreversibility, availability ratio, mass flow rate, and net power output. The results showed that, among the selected working fluids, methanol had the highest thermal efficiency, net power output, second law efficiency, and availability ratio in the range of turbine inlet temperature (TIT) considered. On the other hand, methanol had the smallest total irreversibility in the same range of TIT. The results showed also that mass flow rate and consequently the net power output increased for higher solar irradiation, smaller tube diameter, and for the case of cubical cavity receiver (i.e. cavity depth h equal to the receiver aperture side length a).

  8. ADVANTAGES AND DISADVANTAGES OF THE SONICFILL™ METHOD FOR LATERAL FILLINGS

    Directory of Open Access Journals (Sweden)

    Nicolae BARANOV

    2017-06-01

    Full Text Available The aim of the study was to evaluate the advantages and disadvantages of bulk-fill type fillings realized with SONICFill™ over an 18 month interval, on a batch of patients with different ages and occupations. Materials and methods: the study was performed on a batch of 73 patients who addressed the Clinical of OdontologyEndodontics within the Platform of Practical Training (PIP of the Faculty of Dental Medicine of the ”Apollonia” University of Iaşi, between Octomber 1, 2014 - May 1, 2016, subjected to 91 bulk-fill fillings with SonicFill™ on the posterior teeth. Results and discussion: out of the total number of 73 patients, 56 came from the urban environment, and 17 - from the rural medium, the highest ratio being represented by the 21-30 year age group (45%, closely followed by the 31-40 year one (40%. As for gender distribution within the batch, nearly two-thirds are women, the rest being men. The education level influenced patients’ decision – that of accepting a new method of filling application. As to the types of teeth to which restorations were applied, the highest ratio is represented by lower molars (41%, followed by upper molars (23% and mandibular premolars (20%, the lowest number of restorations being applied to maxillary premolars. Out of the total number of 91 bulk-fill restorations, 28 were applied over a base filling while, in 63 restorations, the basic filling was absent. Conclusions: The SonicFill ™ system for bulk-fill posterior restorations has a number of advantages, such as: high photopolymerization depth, significant reduction of setting contraction, better composite adaptation to the cavity walls, long-term predictable clinical results.

  9. Monitoring Thermal Performance of Hollow Bricks with Different Cavity Fillers in Difference Climate Conditions

    Science.gov (United States)

    Pavlík, Zbyšek; Jerman, Miloš; Fořt, Jan; Černý, Robert

    2015-03-01

    Hollow brick blocks have found widespread use in the building industry during the last decades. The increasing requirements to the thermal insulation properties of building envelopes given by the national standards in Europe led the brick producers to reduce the production of common solid bricks. Brick blocks with more or less complex systems of internal cavities replaced the traditional bricks and became dominant on the building ceramics market. However, contrary to the solid bricks where the thermal conductivity can easily be measured by standard methods, the complex geometry of hollow brick blocks makes the application of common techniques impossible. In this paper, a steady-state technique utilizing a system of two climatic chambers separated by a connecting tunnel for sample positioning is used for the determination of the thermal conductivity, thermal resistance, and thermal transmittance ( U value) of hollow bricks with the cavities filled by air, two different types of mineral wool, polystyrene balls, and foam polyurethane. The particular brick block is provided with the necessary temperature- and heat-flux sensors and thermally insulated in the tunnel. In the climatic chambers, different temperatures are set. After steady-state conditions are established in the measuring system, the effective thermal properties of the brick block are calculated using the measured data. Experimental results show that the best results are achieved with hydrophilic mineral wool as a cavity filler; the worst performance exhibits the brick block with air-filled cavities.

  10. The Patient Care During Before Radiotherapy in Oral Cavity Cancer

    International Nuclear Information System (INIS)

    Jeon, Byeong Chul; Park, Jae Il

    1995-01-01

    All patients who will Undergo irradiation of the oral cavity cancer will need dental before and during Radiotherapy. The extent of the region and the presence of numerous critical normal tissues(mucosa, gingiva, teeth and the alveolar ridge, alveolar bony structure, etc) in the oral cavity area, injury to which could result in serious functional impairment. Therefore I evaluate the Usefulness of custom-made intraoral shielding device before and during Radiotherapy in oral cavity cancer. Materials and Methods (1): Manufacture process of Custom-made intraoral shielding device Containing Cerroband. A. Acquisition of impression B. Matrix Constitution C. Separation by Separator D. Sprinkle on method E. Trimming F. Spacing G. Fill with Cerroband Materials and Methods (2):A. Preannealing B. TLD Set up C. Annealing D. TLD Reading Results = Therefore dosimetric characteristics in oral cavity by TLD Compared to isodose curve dose distribution Ipsilateral oral mucosa, Contralateral oral mucosa, alveolar ridge, tongue, dose was reduced by intraoral shielding device containing Cerroband technique Compared to isodose plan. The custom-made intra-oral shielding device containing Cerroband was useful in reducing the Contralateral oral mucosa dose and Volume irradiated.

  11. [Creep of amalgam fillings under clasp rests].

    Science.gov (United States)

    Borchers, L; Jung, T; West, M

    1989-10-01

    A clinically realistic experiment was set up to obtain information on the amount of vertical settling of clasp rests in amalgam restorations under functional loading. Mesioocclusal cavities were prepared in 16 lower molar specimens cast in brass. The cavities were filled with amalgam and provided with a mesial rest seat. A constant load of 100 N was applied via a simplified (experimental) saddle to a cobalt-chromium E-clasp cast to the saddle. The duration of the load corresponded to 160 days of clinical function. The chronological course of vertical displacement was analyzed mathematically. According to this result the process can be divided into three components: settling immediately upon load initiation (mean value 96 microns, transition creep (mean value 25 microns) and creep ata constant rate (mean value 15 microns). The mean overall vertical displacement of the rests was 136 microns, the maximum value 287 microns. These findings suggest that vertical settling of a clasp rest into its seat in an amalgam restoration may eventually result in significant changes in occlusion and may almost completely exhaust gingival resilience.

  12. TEMPERATURE AND EXTREME-ULTRAVIOLET INTENSITY IN A CORONAL PROMINENCE CAVITY AND STREAMER

    Energy Technology Data Exchange (ETDEWEB)

    Kucera, T. A. [NASA/GSFC, Code 671, Greenbelt, MD 20771 (United States); Gibson, S. E.; Schmit, D. J. [HAO/NCAR, P.O. Box 3000, Boulder, CO 80307-3000 (United States); Landi, E. [Department of Atmospheric, Oceanic and Space Science, Space Research Building, University of Michigan, 2455 Hayward St., Ann Arbor, MI 48109-2143 (United States); Tripathi, D. [Inter-University Centre for Astronomy and Astrophysics, Post Bag-4, Ganeshkhind, Pune University Campus, Pune 411 007 (India)

    2012-09-20

    We analyze the temperature and EUV line emission of a coronal cavity and surrounding streamer in terms of a morphological forward model. We use a series of iron line ratios observed with the Hinode Extreme-ultraviolet Imaging Spectrograph (EIS) on 2007 August 9 to constrain temperature as a function of altitude in a morphological forward model of the streamer and cavity. We also compare model predictions to the EIS EUV line intensities and polarized brightness (pB) data from the Mauna Loa Solar Observatory (MLSO) Mark 4 K-coronameter. This work builds on earlier analysis using the same model to determine geometry of and density in the same cavity and streamer. The fit to the data with altitude-dependent temperature profiles indicates that both the streamer and cavity have temperatures in the range 1.4-1.7 MK. However, the cavity exhibits substantial substructure such that the altitude-dependent temperature profile is not sufficient to completely model conditions in the cavity. Coronal prominence cavities are structured by magnetism so clues to this structure are to be found in their plasma properties. These temperature substructures are likely related to structures in the cavity magnetic field. Furthermore, we find that the model overestimates the EUV line intensities by a factor of 4-10, without overestimating pB. We discuss this difference in terms of filling factors and uncertainties in density diagnostics and elemental abundances.

  13. A multidomain chebyshev pseudo-spectral method for fluid flow and heat transfer from square cylinders

    KAUST Repository

    Wang, Zhiheng

    2015-01-01

    A simple multidomain Chebyshev pseudo-spectral method is developed for two-dimensional fluid flow and heat transfer over square cylinders. The incompressible Navier-Stokes equations with primitive variables are discretized in several subdomains of the computational domain. The velocities and pressure are discretized with the same order of Chebyshev polynomials, i.e., the PN-PN method. The Projection method is applied in coupling the pressure with the velocity. The present method is first validated by benchmark problems of natural convection in a square cavity. Then the method based on multidomains is applied to simulate fluid flow and heat transfer from square cylinders. The numerical results agree well with the existing results. © Taylor & Francis Group, LLC.

  14. Simulation of plasma loading of high-pressure RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Samulyak, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Computational Science Initiative; Stony Brook Univ., NY (United States). Dept. of Applied Mathematics and Statistics; Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Freemire, B. [Northern Illinois Univ., DeKalb, IL (United States)

    2018-01-11

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have also been performed in the range of parameters typical for practical muon cooling channels.

  15. Simulation of plasma loading of high-pressure RF cavities

    Science.gov (United States)

    Yu, K.; Samulyak, R.; Yonehara, K.; Freemire, B.

    2018-01-01

    Muon beam-induced plasma loading of radio-frequency (RF) cavities filled with high pressure hydrogen gas with 1% dry air dopant has been studied via numerical simulations. The electromagnetic code SPACE, that resolves relevant atomic physics processes, including ionization by the muon beam, electron attachment to dopant molecules, and electron-ion and ion-ion recombination, has been used. Simulations studies have been performed in the range of parameters typical for practical muon cooling channels.

  16. A Rare Tumor of Nasal Cavity: Glomangiopericytoma

    Directory of Open Access Journals (Sweden)

    Aysegul Verim

    2014-01-01

    Full Text Available Glomangiopericytoma is a rare vascular neoplasm characterized by a pattern of prominent perivascular growth. A 72-year-old woman was admitted to our clinic complaining of nasal obstruction, frequent epistaxis, and facial pain. A reddish tumor filling the left nasal cavity was observed on endoscopy and treated with endoscopic excision. Microscopically, closely packed cells interspersed with numerous thin-walled, branching staghorn vessels were seen. Glomangiopericytoma is categorized as a borderline low malignancy tumor by WHO classification. Long-term follow-up with systemic examination is necessary due to high risk of recurrence.

  17. Study on the spectrum of photonic crystal cavity and its application in measuring the concentration of NaCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yun [Nanjing Agricultural Univ., Nanjing (China). Dept. of Physics; Wuxi Institute of Commerce, Wuxi (China). School of Electromechanical Technology; Xie, Xun; Hao, Jiong-Ju; Yang, Hong-Wei [Nanjing Agricultural Univ., Nanjing (China). Dept. of Physics; Yang, Ze-Kun [Lanzhou Univ. (China). School of Information Science and Engineering; Xu, Zhi-Gang [Nanjing Agricultural Univ., Nanjing (China). College of Agriculture

    2017-07-01

    In this article, we propose an approach to measure solution concentrations by using photonic crystal cavities. Based on the experimental data, the refractive index of a NaCl solution is proportional to the concentration. Filling the proposed photonic crystal cavity with a NaCl solution, we calculate the spectral transmission using the transfer matrix method. We found that the cavity transmittance was proportional to the refractive index of the NaCl solution, and thus we obtained a linear relationship between cavity transmittance and the concentration of the NaCl solution. The formula was found by fitting the simulation results with experimental data. Such a formula can be applied to the measurement of an unknown concentration of NaCl solution utilizing a photonic crystal cavity.

  18. Program system for calculating streaming neutron radiation field in reactor cavity

    International Nuclear Information System (INIS)

    He Zhongliang; Zhao Shu.

    1986-01-01

    The A23 neutron albedo data base based on Monte Carlo method well agrees with SAIL albedo data base. RSCAM program system, using Monte Carlo method with albedo approach, is used to calculate streaming neutron radiation field in reactor cavity and containment operating hall. The dose rate distributions calculated with RSCAM in square concrete duct well agree with experiments

  19. Inertial Waves and Steady Flows in a Liquid Filled Librating Cylinder

    Science.gov (United States)

    Subbotin, Stanislav; Dyakova, Veronika

    2018-05-01

    The fluid flow in a non-uniformly rotating (librating) cylinder about a horizontal axis is experimentally studied. In the absence of librations the fluid performs a solid-body rotation together with the cavity. Librations lead to the appearance of steady zonal flow in the whole cylinder and the intensive steady toroidal flows near the cavity corners. If the frequency of librations is twice lower than the mean rotation rate the inertial waves are excited. The oscillating motion associated with the propagation of inertial wave in the fluid bulk leads to the appearance of an additional steady flow in the Stokes boundary layers on the cavity side wall. In this case the heavy particles of the visualizer are assembled on the side wall into ring structures. The patterns are determined by the structure of steady flow, which in turn depends on the number of reflections of inertial wave beams from the cavity side wall. For some frequencies, inertial waves experience spatial resonance, resulting in inertial modes, which are eigenmodes of the cavity geometry. The resonance of the inertial modes modifies the steady flow structure close to the boundary layer that is manifested in the direct rebuilding of patterns. It is shown that the intensity of zonal flow, as well as the intensity of steady flows excited by inertial waves, is proportional to the square of the amplitude of librations.

  20. Superconducting magnesium diboride coatings for radio frequency cavities fabricated by hybrid physical-chemical vapor deposition

    Science.gov (United States)

    Wolak, M. A.; Tan, T.; Krick, A.; Johnson, E.; Hambe, M.; Chen, Ke; Xi, X. X.

    2014-01-01

    We have investigated the coating of an inner surface of superconducting radio frequency cavities with a magnesium diboride thin film by hybrid physical-chemical vapor deposition (HPCVD). To simulate a 6 GHz rf cavity, a straight stainless steel tube of 1.5-inch inner diameter and a dummy stainless steel cavity were employed, on which small sapphire and metal substrates were mounted at different locations. The MgB2 films on these substrates showed uniformly good superconducting properties including Tc of 37-40 K, residual resistivity ratio of up to 14, and root-mean-square roughness Rq of 20-30 nm. This work demonstrates the feasibility of coating the interior of cylindrical and curved objects with MgB2 by the HPCVD technique, an important step towards superconducting rf cavities with MgB2 coating.

  1. Analytical and semi-analytical formalism for the voltage and the current sources of a superconducting cavity under dynamic detuning

    CERN Document Server

    Doleans, M

    2003-01-01

    Elliptical superconducting radio frequency (SRF) cavities are sensitive to frequency detuning because they have a high Q value in comparison with normal conducting cavities and weak mechanical properties. Radiation pressure on the cavity walls, microphonics, and tuning system are possible sources of dynamic detuning during SRF cavity-pulsed operation. A general analytic relation between the cavity voltage, the dynamic detuning function, and the RF control function is developed. This expression for the voltage envelope in a cavity under dynamic detuning and dynamic RF controls is analytically expressed through an integral formulation. A semi-analytical scheme is derived to calculate the voltage behavior in any practical case. Examples of voltage envelope behavior for different cases of dynamic detuning and RF control functions are shown. The RF control function for a cavity under dynamic detuning is also investigated and as an application various filling schemes are presented.

  2. Characterizing cavities in model inclusion molecules: a comparative study.

    Science.gov (United States)

    Torrens, F; Sánchez-Marín, J; Nebot-Gil, I

    1998-04-01

    We have selected fullerene-60 and -70 cavities as model systems in order to test several methods for characterizing inclusion molecules. The methods are based on different technical foundations such as a square and triangular tessellation of the molecule taken as a unitary sphere, spherical tessellation of the molecular surface, numerical integration of the atomic volumes and surfaces, triangular tessellation of the molecular surface, and a cubic lattice approach to a molecular space. Accurate measures of the molecular volume and surface area have been performed with the pseudo-random Monte Carlo (MCVS) and uniform Monte Carlo (UMCVS) methods. These calculations serve as a reference for the rest of the methods. The SURMO2 and MS methods have not recognized the cavities and may not be convenient for intercalation compounds. The programs that have detected the cavities never exceed 5% deviation relative to the reference values for molecular volume and surface area. The GEPOL algorithm, alone or combined with TOPO, shows results in good agreement with those of the UMCVS reference. The uniform random number generator provides the fastest convergence for UMCVS and a correct estimate of the standard deviations. The effect of the internal cavity on the accessible surfaces has been calculated.

  3. Characterizing Cavities in Model Inclusion Fullerenes: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Francisco Torrens

    2001-06-01

    Full Text Available Abstract: The fullerene-82 cavity is selected as a model system in order to test several methods for characterizing inclusion molecules. The methods are based on different technical foundations such as a square and triangular tessellation of the molecular surface, spherical tessellation of the molecular surface, numerical integration of the atomic volumes and surfaces, triangular tessellation of the molecular surface, and cubic lattice approach to the molecular volume. Accurate measures of the molecular volume and surface area have been performed with the pseudorandom Monte Carlo (MCVS and uniform Monte Carlo (UMCVS methods. These calculations serve as a reference for the rest of the methods. The SURMO2 method does not recognize the cavity and may not be convenient for intercalation compounds. The programs that detect the cavities never exceed 1% deviation relative to the reference value for molecular volume and 5% for surface area. The GEPOL algorithm, alone or combined with TOPO, shows results in good agreement with those of the UMCVS reference. The uniform random number generator provides the fastest convergence for UMCVS and a correct estimate of the standard deviations. The effect of the internal cavity on the solvent-accessible surfaces has been calculated. Fullerene-82 is compared with fullerene-60 and -70.

  4. Hardware-efficient fermionic simulation with a cavity-QED system

    Science.gov (United States)

    Zhu, Guanyu; Subaşı, Yiǧit; Whitfield, James D.; Hafezi, Mohammad

    2018-03-01

    In digital quantum simulation of fermionic models with qubits, non-local maps for encoding are often encountered. Such maps require linear or logarithmic overhead in circuit depth which could render the simulation useless, for a given decoherence time. Here we show how one can use a cavity-QED system to perform digital quantum simulation of fermionic models. In particular, we show that highly nonlocal Jordan-Wigner or Bravyi-Kitaev transformations can be efficiently implemented through a hardware approach. The key idea is using ancilla cavity modes, which are dispersively coupled to a qubit string, to collectively manipulate and measure qubit states. Our scheme reduces the circuit depth in each Trotter step of the Jordan-Wigner encoding by a factor of N2, comparing to the scheme for a device with only local connectivity, where N is the number of orbitals for a generic two-body Hamiltonian. Additional analysis for the Fermi-Hubbard model on an N × N square lattice results in a similar reduction. We also discuss a detailed implementation of our scheme with superconducting qubits and cavities.

  5. Healing process following application of set or fresh mineral trioxide aggregate as a root-end filling material.

    Science.gov (United States)

    Habibi, Mehdi; Ghoddusi, Jamileh; Habibi, Ataollah; Mohtasham, Nooshin

    2011-01-01

    An unsuccessful attempt to reach the apical area or to place the retrograde material is a major difficulty in periradicular surgery. The aim of this study was to compare the histological evaluation of the healing process following an orthograde versus a retrograde application of mineral trioxide aggregate (MTA) as a root-end filling material during apical surgery on cats' teeth in order to find out whether orthograde placement of MTA before surgery can be used instead of retrograde placement during surgery. In this experimental study, 24 canine teeth in 12 mature and healthy cats were filled with either MTA or gutta-percha in an orthograde manner. Two weeks later, the teeth with MTA were surgically exposed and resected to the set-MTA within the canals. The teeth previously filled by gutta-percha were also surgically exposed, and retrograde cavities were prepared at the root ends and filled with fresh-MTA. After 8 weeks, the animals were euthanized by vital perfusion. Six-micron histological slices were prepared from samples, stained by Hematoxylin & Eosin, and histologically studied by means of a light microscope. The collected data was analyzed by the Chi-square and the T-test. One of the samples in the fresh-MTA group was omitted during processing because of inappropriate sectioning. In the set-MTA group, 5 out of 12 showed chronic abscess, while in the fresh-MTA group, 2 out of 11 were discovered to have chronic abscess; however, no significant difference was observed (P>.05). Hard tissue healing (cementum, bone, cementum + bone formation) in the set-MTA and fresh-MTA groups were 7 out of 12 and 9 out of 11, respectively. While healing seemed more likely to occur in the fresh-MTA group, the difference was statistically insignificant (P>.05). The magnitude of bone, cementum, or bone and cementum formation showed slight differences between the two groups; however, the figures failed to show any marked differences (P>.05). Orthograde placement of MTA could be used

  6. Mixed convection of nanofluids in a lid-driven rough cavity

    Science.gov (United States)

    Guo, Zhimeng; Wang, Jinyu; Mozumder, Aloke K.; Das, Prodip K.

    2017-06-01

    Mixed convection heat transfer and fluid flow of air, water or oil in enclosures have been studied extensively using experimental and numerical means for many years due to their ever-increasing applications in many engineering fields. In comparison, little effort has been given to the problem of mixed convection of nanofluids in spite of several applications in solar collectors, electronic cooling, lubrication technologies, food processing, and nuclear reactors. Mixed convection of nanofluids is a challenging problem due to the complex interactions among inertia, viscous, and buoyancy forces. In this study, mixed convection of nanofluids in a lid-driven square cavity with sinusoidal roughness elements at the bottom is studied numerically using the Navier-Stokes equations with the Boussinesq approximation. The numerical model is developed using commercial finite volume software ANSYS-FLUENT for Al2O3-water and CuO-water nanofluids inside a square cavity with various roughness elements. The effects of number and amplitude of roughness elements on the heat transfer and fluid flow are analysed for various volume concentrations of Al2O3 and CuO nanoparticles. The flow fields, temperature fields, and heat transfer rates are examined for different values of Rayleigh and Reynolds numbers. The outcome of this study provides some important insight into the heat transfer behaviour of Al2O3-water and CuO-water nanofluids inside a lid-driven rough cavity. This knowledge can be further used in developing novel geometries with enhanced and controlled heat transfer for solar collectors, electronic cooling, and food processing industries.

  7. Perception of Length to Width Relations of City Squares

    Directory of Open Access Journals (Sweden)

    Harold T. Nefs

    2013-04-01

    Full Text Available In this paper, we focus on how people perceive the aspect ratio of city squares. Earlier research has focused on distance perception but not so much on the perceived aspect ratio of the surrounding space. Furthermore, those studies have focused on “open” spaces rather than urban areas enclosed by walls, houses and filled with people, cars, etc. In two experiments, we therefore measured, using a direct and an indirect method, the perceived aspect ratio of five city squares in the historic city center of Delft, the Netherlands. We also evaluated whether the perceived aspect ratio of city squares was affected by the position of the observer on the square. In the first experiment, participants were asked to set the aspect ratio of a small rectangle such that it matched the perceived aspect ratio of the city square. In the second experiment, participants were asked to estimate the length and width of the city square separately. In the first experiment, we found that the perceived aspect ratio was in general lower than the physical aspect ratio. However, in the second experiment, we found that the calculated ratios were close to veridical except for the most elongated city square. We conclude therefore that the outcome depends on how the measurements are performed. Furthermore, although indirect measurements are nearly veridical, the perceived aspect ratio is an underestimation of the physical aspect ratio when measured in a direct way. Moreover, the perceived aspect ratio also depends on the location of the observer. These results may be beneficial to the design of large open urban environments, and in particular to rectangular city squares.

  8. Maintenance of the resonance in a cavity filled with a variable density plasma; Entretien de la resonance d'une cavite chargee par un plasma de densite variable

    Energy Technology Data Exchange (ETDEWEB)

    Melin, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A study has been made of the possibility of keeping in resonance a cavity filled with a plasma of variable density; only the low HF power zone has been examined (less than a few dozen W). A calculation is first made, for the chosen experimental conditions, of the slipping of the resonance frequency of a cavity as a function of the plasma parameters (density, temperature), with a view to obtaining an idea of its importance. A description is then given of the experimental set-up: the S band cavity (3000 Mc/sec) is supplied by a carcinotron type generator; use is made of the plasma of a positive column whose density ({approx}10{sup 11} cm{sup -3}) can easily be controlled so as to obtain slipping of the cavity frequency ({delta}F{sub max} {approx} 50 Mc/s). The zone of automatic agreement thus obtained for the S band is 3 per cent continuously ({approx}100 Mc/s) and 1 per cent ({approx}30 Mc/s) with a response time of 10 {mu}s (sudden changes in density, {delta}n {approx} 5.10{sup 10} cm{sup 3}). These characteristics already compare very favorably with existing systems, and can easily be improved. (author) [French] On etudie une possibilite de maintenir a la resonance une cavite chargee par un plasma dont la densite varie; on se limite au domaine des puissances HF faibles (< quelques dizaines de W). On calcule tout d'abord, pour les conditions experimentales choisies, le glissement de la frequence de resonance d'une cavite en fonction des parametres du plasma, densite, temperature, pour en evaluer les ordres de grandeur. On decrit ensuite la realisation experimentale: la cavite bande S (3000 Mc/s) est alimentee par un generateur du type carcinotron; on utilise le plasma d'une colonne positive, dont on controle facilement la densite ({approx}10{sup 11} cm{sup -3}) pour faire glisser en frequence la cavite ({delta}F{sub max} {approx} 50 Mc/s). La zone d'accord automatique obtenue ainsi pour la bande S est de 3 pour cent en continu ({approx}100 Mc/s), de 1 pour cent

  9. Liquid detection with InGaAsP semiconductor lasers having multiple short external cavities.

    Science.gov (United States)

    Zhu, X; Cassidy, D T

    1996-08-20

    A liquid detection system consisting of a diode laser with multiple short external cavities (MSXC's) is reported. The MSXC diode laser operates single mode on one of 18 distinct modes that span a range of 72 nm. We selected the modes by setting the length of one of the external cavities using a piezoelectric positioner. One can measure the transmission through cells by modulating the injection current at audio frequencies and using phase-sensitive detection to reject the ambient light and reduce 1/f noise. A method to determine regions of single-mode operation by the rms of the output of the laser is described. The transmission data were processed by multivariate calibration techniques, i.e., partial least squares and principal component regression. Water concentration in acetone was used to demonstrate the performance of the system. A correlation coefficient of R(2) = 0.997 and 0.29% root-mean-square error of prediction are found for water concentration over the range of 2-19%.

  10. Marginal Gap Formation in Approximal "Bulk Fill" Resin Composite Restorations After Artificial Ageing.

    Science.gov (United States)

    Peutzfeldt, A; Mühlebach, S; Lussi, A; Flury, S

    The aim of this in vitro study was to investigate the marginal gap formation of a packable "regular" resin composite (Filtek Supreme XTE [3M ESPE]) and two flowable "bulk fill" resin composites (Filtek Bulk Fill [3M ESPE] and SDR [DENTSPLY DeTrey]) along the approximal margins of Class II restorations. In each of 39 extracted human molars (n=13 per resin composite), mesial and distal Class II cavities were prepared, placing the gingival margins below the cemento-enamel junction. The cavities were restored with the adhesive system OptiBond FL (Kerr) and one of the three resin composites. After restoration, each molar was cut in half in the oro-vestibular direction between the two restorations, resulting in two specimens per molar. Polyvinylsiloxane impressions were taken and "baseline" replicas were produced. The specimens were then divided into two groups: At the beginning of each month over the course of six months' tap water storage (37°C), one specimen per molar was subjected to mechanical toothbrushing, whereas the other was subjected to thermocycling. After artificial ageing, "final" replicas were produced. Baseline and final replicas were examined under the scanning electron microscope (SEM), and the SEM micrographs were used to determine the percentage of marginal gap formation in enamel or dentin. Paramarginal gaps were registered. The percentages of marginal gap formation were statistically analyzed with a nonparametric analysis of variance followed by Wilcoxon-Mann-Whitney tests and Wilcoxon signed rank tests, and all p-values were corrected with the Bonferroni-Holm adjustment for multiple testing (significance level: α=0.05). Paramarginal gaps were analyzed descriptively. In enamel, significantly lower marginal gap formation was found for Filtek Supreme XTE compared to Filtek Bulk Fill ( p=0.0052) and SDR ( p=0.0289), with no significant difference between Filtek Bulk Fill and SDR ( p=0.4072). In dentin, significantly lower marginal gap formation was

  11. Modeling of MHD natural convection in a square enclosure having an adiabatic square shaped body using Lattice Boltzmann Method

    Directory of Open Access Journals (Sweden)

    Ahmed Kadhim Hussein

    2016-03-01

    Full Text Available A steady laminar two-dimensional magneto-hydrodynamics (MHD natural convection flow in a square enclosure filled with an electrically conducting fluid is numerically investigated using Lattice Boltzmann Method (LBM. The left and right vertical sidewalls of the square enclosure are maintained at hot and cold temperatures respectively. The horizontal top and bottom walls are considered thermally insulated. An adiabatic square shaped body is located in the center of a square enclosure and an external magnetic field is applied parallel to the horizontal x-axis. In the present work, the following parametric ranges of the non-dimensional groups are utilized: Hartmann number is varied as 0 ⩽ Ha ⩽ 50, Rayleigh number is varied as 103 ⩽ Ra ⩽ 105, Prandtl number is varied 0.05 ⩽ Pr ⩽ 5. It is found that the Hartmann number, Rayleigh number, and Prandtl number have an important role on the flow and thermal characteristics. It is found that when the Hartmann number increases the average Nusselt number decreases. The results also explain that the effect of magnetic field on flow field increases by increasing Prandtl number. However, the Prandtl number effect on the average Nusselt number with a magnetic field is less than the case without a magnetic field. Comparisons with previously published numerical works are performed and good agreements between the results are observed.

  12. Hydrologic processes and radionuclide distribution in a cavity and chimney produced by the Cannikin nuclear explosion, Amchitka Island, Alaska

    International Nuclear Information System (INIS)

    Claassen, H.C.

    1978-01-01

    An analysis of hydraulic, chemical, and radiochemical data obtained in the vicinity of the site of a nuclear explosion (code-named Cannikin, 1971), on Amchitka Island, Alaska, was undertaken to describe the hydrologic processes associated with the saturation of subsurface void space produced by the explosion. Immediately after detonation of the explosive, a subsurface cavity was created surrounding the explosion point. This cavity soon was partly filled by collapse of overburden, producing void volume in a rubble chimney extending to land surface and forming a surface-collapse sink. Surface and groundwater immediately began filling the chimney but was excluded for a time from the cavity by the presence of steam. When the steam condensed, the accumulated water in the chimney flowed into the cavity region, picking up and depositing radioactive materials along its path. Refilling of the chimney voids then resumed and was nearly complete about 260 days after the explosion. The hydraulic properties of identified aquifers intersecting the chimney were used with estimates of surface-water inflow, chimney dimensions, and the measured water-level rise in the chimney to estimate the distribution of explosion-created porosity in the chimney, which ranged from about 10 percent near the bottom to 4 percent near the top. Chemical and radiochemical analyses of water from the cavity resulted in identification of three aqueous phases: groundwater, surface water, and condensed steam. Although most water samples represented mixtures of these phases, they contained radioactivity representative of all radioactivity produced by the explosion

  13. Cavity-type hypersonic phononic crystals

    International Nuclear Information System (INIS)

    Sato, A; Fytas, G; Pennec, Y; Djafari-Rouhani, B; Yanagishita, T; Masuda, H; Knoll, W

    2012-01-01

    We report on the engineering of the phonon dispersion diagram in monodomain anodic porous alumina (APA) films through the porosity and physical state of the material residing in the nanopores. Lattice symmetry and inclusion materials are theoretically identified to be the main factors which control the hypersonic acoustic wave propagation. This involves the interaction between the longitudinal and the transverse modes in the effective medium and a flat band characteristic of the material residing in the cavities. Air and filled nanopores, therefore, display markedly different dispersion relations and the inclusion materials lead to a locally resonant structural behavior uniquely determining their properties under confinement. APA films emerge as a new platform to investigate the rich acoustic phenomena of structured composite matter. (paper)

  14. Superconducting magnesium diboride coatings for radio frequency cavities fabricated by hybrid physical-chemical vapor deposition

    Directory of Open Access Journals (Sweden)

    M. A. Wolak

    2014-01-01

    Full Text Available We have investigated the coating of an inner surface of superconducting radio frequency cavities with a magnesium diboride thin film by hybrid physical-chemical vapor deposition (HPCVD. To simulate a 6 GHz rf cavity, a straight stainless steel tube of 1.5-inch inner diameter and a dummy stainless steel cavity were employed, on which small sapphire and metal substrates were mounted at different locations. The MgB_{2} films on these substrates showed uniformly good superconducting properties including T_{c} of 37–40 K, residual resistivity ratio of up to 14, and root-mean-square roughness R_{q} of 20–30 nm. This work demonstrates the feasibility of coating the interior of cylindrical and curved objects with MgB_{2} by the HPCVD technique, an important step towards superconducting rf cavities with MgB_{2} coating.

  15. Push-Out Bond Strength of Restorations with Bulk-Fill, Flow, and Conventional Resin Composites

    Directory of Open Access Journals (Sweden)

    Rodrigo Vieira Caixeta

    2015-01-01

    Full Text Available The aim of this study was to evaluate the bond strengths of composite restorations made with different filler amounts and resin composites that were photoactivated using a light-emitting diode (LED. Thirty bovine incisors were selected, and a conical cavity was prepared in the facial surface of each tooth. All preparations were etched with Scotchbond Etching Gel, the Adper Scotchbond Multipurpose Plus adhesive system was applied followed by photoactivation, and the cavities were filled with a single increment of Filtek Z350 XT, Filtek Z350 XT Flow, or bulk-fill X-tra fil resin composite (n = 10 followed by photoactivation. A push-out test to determine bond strength was conducted using a universal testing machine. Data (MPa were submitted to Student’s t-test at a 5% significance level. After the test, the fractured specimens were examined using an optical microscope under magnification (10x. Although all three composites demonstrated a high prevalence of adhesive failures, the bond strength values of the different resin composites photoactivated by LED showed that the X-tra fil resin composite had a lower bond strength than the Filtek Z350 XT and Filtek Z350 XT Flow resin composites.

  16. Cavities as the sources of acid mine process in the Niwka-Modrzejow Coal Mine (poland)

    International Nuclear Information System (INIS)

    Pluta, I.; Mazurkiewicz, M.

    2005-01-01

    Acid mine process is one of the most significant sources the pollution of surface water. The intensive process was discovered in the Niwka-Modrzejow Coal Mine at the level 100-130 m. In this paper the method of prevention by the filling cavities of wastes from energy plants was proposed. (authors)

  17. Outcome of endodontic treatment of teeth filled using lateral condensation versus vertical compaction (Schilder's technique).

    Science.gov (United States)

    Aqrabawi, Jamal A

    2006-02-15

    The purpose of this prospective clinical and radiographic investigation was to assess the treatment results following endodontic therapy of teeth filled with lateral condensation versus teeth filled with vertical compaction of warm gutta-percha. A total of 290 patients were treated using the standardized step-back technique for canal preparation, which were filled with either lateral condensation or vertical compaction in one single session. Five years later, the treatment results were assessed clinically and radiographically and related to the type of the obturation technique using Chi-square analysis. Of the 340 teeth that were reexamined, 160 teeth were filled with lateral condensation, and 180 teeth were filled with vertical condensation. The results showed a significantly higher success rate for the vertical compaction versus the lateral condensation technique of teeth presented with preoperative periapical lesions P<0.04. Regardless of the preoperative periapical status of the teeth, no statistically significant difference was found between the two techniques. The overall success rate of both filling techniques was 80.3%.

  18. Burning test on a storage drum filled with a mixture of sodiumnitrate and bitumen

    International Nuclear Information System (INIS)

    Knotik, K.; Leichter, P.; Spalek, K.

    1979-01-01

    A burning test on a common storage drum filled with a mixture of sodiumnitrate and bitumen was carried out to show the incinerability of said mixture. A 50 l mild steel drum was filled with 80,7 kg sodiumnitrate/bitumen-mixture. The drum was packed in a 200 l mild steel drum, the remaining space was filled with enough sand to cover the top of the inner drum with 15 cm of sand. The sand packing was then soaked with 70 l of light distillate fuel and ignited. The fuel burned until self-extinguishing occurred. 30 % (22,2 l) of the fuel was burned. 0,7 % of the energy potential was absorbed in the sand layer. The highest measured temperature was 34 0 C at the top of the test drum. It can be concluded, that even under severe external actions the ignition temperature of 400 0 C for bitumen/waste mixtures cannot be reached, providing correct technical storage conditions, which means that the void space in the cavities is filled with unburnable absorbing material like sand or salt. (author)

  19. Differentiated heated lid driven cavity interacting with tube: A lattice Boltzmann study

    Directory of Open Access Journals (Sweden)

    Bennacer Rachid

    2017-01-01

    Full Text Available The multiple-relaxation-time (MRT lattice-Boltzmann method is implemented to investigate combined natural and forced convection occurring in a two-dimensional square cavity. The top wall slides to the right at constant speed, while the other three remain stationary. The solution is performed for a left vertical wall at a constant temperature, which is higher than of the right wall. This yields a “cooperating” case, in which dynamic and buoyancy forces are added together. The enclosure is filled with air and contains a heat conducting circular cylinder, which is placed at various positions. The double distribution model used in lattice Boltzmann methods has been adopted to simulate the hydrodynamic and thermal fields, with the D2Q9 and D2Q5 lattices selected to perform the corresponding computations. Simulations have been conducted over a wide range of Rayleigh (Ra and Reynolds (Re numbers, and the features of dynamic and thermal fields are presented for the spectra of this mixed convection phenomenon. The flow and heat transfer characteristics of the cylinder position are described and analyzed in terms of the average Nusselt number (Nu. The computed results show the influence of the cylinder on the corresponding heat transfer in the enclosure. It has been found that the power (i.e. shear stress needed to lid the upper surface will depend on the governing parameters.

  20. Evaluation of interference of calcium hydroxide-based intracanal medication in filling root canal systems.

    Science.gov (United States)

    Vilela, Deyla Duarte; Neto, Manoel Matos; Villela, Alexandre Mascarenhas; Pithon, Matheus Melo

    2011-09-01

    To evaluate the interference of the intracanal medication Calen® (SSWhite, Sao Paulo, Brazil) on the filling of simulated lateral canals. Twenty human anterior teeth were used. Before the endodontic filling procedures the access of cavity was made, and after this root canals were made in all the teeth to simulate the presence of lateral canals. After preparation, the teeth were randomly divided into two groups (n=10). In group I, the root canal system was filled directly after chemicalmechanical preparation; in group II, endodontic treatment was performed in multiple sessions, and after preparation the calcium hydroxide-based intracanal medication Calen® was inserted. After the period of 7 days, the root canals were vigorously irrigated and then they were filled. Next, the teeth were radiographed to verify the quality of the filling. The results demonstrated that the teeth treated in a single session, without calcium hydroxide medication, presented 47 canals out of 60 with radiographic evidence of filling, whereas the teeth in which intracanal medication was used, only 07 presented a radiographic image compatible with filling (p < 0.05). The use of the calcium hydroxide-based medication Calen made it difficult to obtain a hermetic filling of the root canal system. The clinical significance of this work basing on the fact that once the dentist knowing that property obliteration of calcium hydroxide can be taken care when they are used in the presence of lateral canals.

  1. Simulation and scaling for natural convection flow in a cavity with isothermal boundaries

    International Nuclear Information System (INIS)

    Jiracheewanun, S.; Armfield, S.W.; McBain, G.D.; Behnia, M.

    2005-01-01

    A numerical study of the transient two-dimensional natural convection flow within a differentially heated square cavity with iso-flux side walls and adiabatic top and bottom boundaries is presented. The governing equations are discretized using a non-staggered mesh and solved using a non-iterative fractional-step pressure correction method which provides second-order accuracy in both time and space. Results are obtained with the iso-flux boundary condition for Ra = 5.8 x 10 9 and Pr = 7.5. The results show that the transient flow features obtained for the iso-flux cavity are similar to the flow features for the isothermal case. However, the fully developed flow features of the iso-flux cavity are very different from the isothermal case. The scalings for the fully developed iso-flux boundary condition flow have been found to be different to those of the isothermal boundary condition flow. (authors)

  2. [Early diffuse hypertrophic osteitis recurrence. Unexpected and consternating development after a large évidement cavity. Apropos of 15 cases].

    Science.gov (United States)

    Fleury, P; Basset, J M; Candau, P; Bré, M; Despreaux, G; Fabre, A; Saliba, N

    1985-01-01

    The authors report 15 cases collected over a period of 13 years (1972 - 1984) of a particularly serious eventuality affecting certain evacuation cavities: Early recurrence of diffuse hypertrophic osteitis (E.R.D.H.O.). This is a rare complication, occurring in 1.5% of cases of chronic otitis. However, the fact of having operated upon 7 cases in 1984 alone, whilst during the previous 12 years, only 8 had been seen, raised the alarm. The classical pattern of this complication occurs in 3 stages, each involving surgical operation: at the outset, chronic otitis with cholesteatoma or osteitis, most often mixed, for which an "inadequate" surgical procedure is performed. then, after a variable period which may exceed 10 years, a very large evacuation cavity was created by the authors. finally, 3rd and final stage: within 6 months, this cavity filled progressively and, at operation, the authors discovered a cavity virtually completely filled with a "fantastic" "moist sugar" osteitis, requiring a new evacuation cavity, even larger than that created before. In all cases, a successful result was obtained within a varying period, sometimes accompanied by spectacular improvement in general condition. The most plausible etiopathogenic hypothesis advanced to attempt to explain this phenomenon is that of secondary infection by a varied microbial flora, including, on the one hand, aerobic organisms usually discovered in such cases (pseudomonas pyocyaneus, proteus mirabilis) and, secondly, this being of essential importance, "anaerobic" bacteria, the bacteriological diagnosis of which requires application of a strict protocol. The authors have taken three decisions following their bibliographic investigations.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Dosimetric response of variable-size cavities in photon-irradiated media and the behaviour of the Spencer-Attix cavity integral with increasing Δ.

    Science.gov (United States)

    Kumar, Sudhir; Deshpande, Deepak D; Nahum, Alan E

    2016-04-07

    Cavity theory is fundamental to understanding and predicting dosimeter response. Conventional cavity theories have been shown to be consistent with one another by deriving the electron (+positron) and photon fluence spectra with the FLURZnrc user-code (EGSnrc Monte-Carlo system) in large volumes under quasi-CPE for photon beams of 1 MeV and 10 MeV in three materials (water, aluminium and copper) and then using these fluence spectra to evaluate and then inter-compare the Bragg-Gray, Spencer-Attix and 'large photon' 'cavity integrals'. The behaviour of the 'Spencer-Attix dose' (aka restricted cema), D S-A(▵), in a 1-MeV photon field in water has been investigated for a wide range of values of the cavity-size parameter ▵: D S-A(▵) decreases far below the Monte-Carlo dose (D MC) for ▵ greater than  ≈  30 keV due to secondary electrons with starting energies below ▵ not being 'counted'. We show that for a quasi-scatter-free geometry (D S-A(▵)/D MC) is closely equal to the proportion of energy transferred to Compton electrons with initial (kinetic) energies above ▵, derived from the Klein-Nishina (K-N) differential cross section. (D S-A(▵)/D MC) can be used to estimate the maximum size of a detector behaving as a Bragg-Gray cavity in a photon-irradiated medium as a function of photon-beam quality (under quasi CPE) e.g. a typical air-filled ion chamber is 'Bragg-Gray' at (monoenergetic) beam energies  ⩾260 keV. Finally, by varying the density of a silicon cavity (of 2.26 mm diameter and 2.0 mm thickness) in water, the response of different cavity 'sizes' was simulated; the Monte-Carlo-derived ratio D w/D Si for 6 MV and 15 MV photons varied from very close to the Spencer-Attix value at 'gas' densities, agreed well with Burlin cavity theory as ρ increased, and approached large photon behaviour for ρ  ≈  10 g cm(-3). The estimate of ▵ for the Si cavity was improved by incorporating a Monte-Carlo-derived correction for

  4. Study of process parameters effect on the filling phase of micro injection moulding using weld lines as flow markers

    DEFF Research Database (Denmark)

    Tosello, Guido; Gava, Alberto; Hansen, Hans Nørgaard

    2010-01-01

    , the relationships between the filling pattern and the different process parameter settings have to be established. In this paper, a novel approach based on the use of weld lines as flow markers to trace the development of the flow front during the filling is proposed. The effects on the filling stage of process......Micro-injection moulding (micro-moulding) is a process which enables the mass production of polymer microproducts. In order to produce high-quality injection moulded micro-parts, a crucial aspect to be fully understood and optimised is the filling of the cavity by the molten polymer. As a result...... manufactured by micro-electrodischarge machining. A commercially available polystyrene grade polymer has been moulded using a high-speed injection moulding machine. The design of experiment technique was employed to determine the effect of the process parameters on the filling phase of the micro...

  5. Improvement of cavity performance in the Saclay/Cornell/DESY's SC cavities

    International Nuclear Information System (INIS)

    Kako, E.; Noguchi, S.; Ono, M.

    2000-01-01

    Development of 1.3 GHz Nb superconducting cavities for TESLA (TeV Energy Superconducting Linear Collider) has been carried out with international collaboration. Three Saclay single-cell cavities, one Cornell two-cell cavity and one DESY nine-cell cavity were sent to KEK in order to compare the cavity performance. These cavities were tested at KEK after the following surface treatment: 1) high pressure rinsing, HPR, 2) chemical polishing and HPR, 3) electropolishing and HPR. The test results, especially, improvement of the cavity performance due to electropolishing are reported in this paper. (author)

  6. Mixed convection of ferrofluids in a lid driven cavity with two rotating cylinders

    Directory of Open Access Journals (Sweden)

    Fatih Selimefendigil

    2015-09-01

    Full Text Available Mixed convection of ferrofluid filled lid driven cavity in the presence of two rotating cylinders were numerically investigated by using the finite element method. The cavity is heated from below, cooled from driven wall and rotating cylinder surfaces and side vertical walls of the cavity are assumed to be adiabatic. A magnetic dipole source is placed below the bottom wall of the cavity. The study is performed for various values of Reynolds numbers (100 ≤ Re ≤ 1000, angular rotational speed of the cylinders (−400 ≤ Ω ≤ 400, magnetic dipole strengths (0 ≤ γ ≤ 500, angular velocity ratios of the cylinders (0.25≤Ωi/Ωj≤4 and diameter ratios of the cylinders (0.5≤Di/Dj≤2. It is observed that flow patterns and thermal transport within the cavity are affected by variation in Reynolds number and magnetic dipole strength. The results of this investigation revealed that cylinder angular velocities, ratio of the angular velocities and diameter ratios have profound effect on heat transfer enhancement within the cavity. Averaged heat transfer enhancements of 181.5 % is achieved for clockwise rotation of the cylinder at Ω = −400 compared to motionless cylinder case. Increasing the angular velocity ratio from Ω2/Ω1=0.25 to Ω2/Ω1=4 brings about 91.7 % of heat transfer enhancement.

  7. Simulation and experimental verification of the filling process of semi-solid die forging for cup shell

    Directory of Open Access Journals (Sweden)

    Jianbo TAN

    2015-06-01

    Full Text Available The filling mold process of semi-solid alloy blank influences severely the forming and properties of finished piece. In this paper, DEFORM is applied to simulate the process of cup-type 6061 alloy die forging casting. The influences of the temperature of semi-solid alloy blank, preheating temperature, and downward press speed of pressure head on process of mold filling and velocity field are investigated. The results show that the mold filling of semi-solid alloy paste smoothly fills along the whole of mould cavity in “total wall thickness” form when the temperature of semi-solid alloy blank is 620 ℃, preheating temperature of pressure head is 200 ℃ and speed of pressure head is 40 mm/s. Along with the increase of the preheating temperature of pressure head, the filling process of the semi-solid alloy paste trends toward stable when the temperature of semi-solid alloy blank is 620 ℃ and the speed of pressure head is 20 mm/s. Along with the increasing of the temperature of semi-solid alloy, the process of mould filling becomes off balance and the liquid becomes turbulent flow. The velocity field in the process of mould filling affects severely the structure uniformity of the finished product.

  8. Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Susan L.; Pino, Ramiro [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, Methodist Hospital, Houston, Texas 77030 and Texas Cancer Clinic, San Antonio, Texas 78240 (United States)

    2010-08-15

    Purpose: To investigate the dosimetric effect of the air inside the SAVI partial breast irradiation device. Methods: The authors have investigated how the air inside the SAVI partial breast irradiation device changes the delivered dose from the homogeneously calculated dose. Measurements were made with the device filled with air and water to allow comparison to a homogenous dose calculation done by the treatment planning system. Measurements were made with an ion chamber, TLDs, and film. Monte Carlo (MC) simulations of the experiment were done using the EGSnrc suite. The MC model was validated by comparing the water-filled calculations to those from a commercial treatment planning system. Results: The magnitude of the dosimetric effect depends on the size of the cavity, the arrangement of sources, and the relative dwell times. For a simple case using only the central catheter of the largest device, MC results indicate that the dose at the prescription point 1 cm away from the air-water boundary is about 9% higher than the homogeneous calculation. Independent measurements in a water phantom with a similar air cavity gave comparable results. MC simulation of a realistic multidwell position plan showed discrepancies of about 5% on average at the prescription point for the largest device. Conclusions: The dosimetric effect of the air cavity is in the range of 3%-9%. Unless a heterogeneous dose calculation algorithm is used, users should be aware of the possibility of small treatment planning dose errors for this device and make modifications to the treatment delivery, if necessary.

  9. Spectral/hp least-squares finite element formulation for the Navier-Stokes equations

    International Nuclear Information System (INIS)

    Pontaza, J.P.; Reddy, J.N.

    2003-01-01

    We consider the application of least-squares finite element models combined with spectral/hp methods for the numerical solution of viscous flow problems. The paper presents the formulation, validation, and application of a spectral/hp algorithm to the numerical solution of the Navier-Stokes equations governing two- and three-dimensional stationary incompressible and low-speed compressible flows. The Navier-Stokes equations are expressed as an equivalent set of first-order equations by introducing vorticity or velocity gradients as additional independent variables and the least-squares method is used to develop the finite element model. High-order element expansions are used to construct the discrete model. The discrete model thus obtained is linearized by Newton's method, resulting in a linear system of equations with a symmetric positive definite coefficient matrix that is solved in a fully coupled manner by a preconditioned conjugate gradient method. Spectral convergence of the L 2 least-squares functional and L 2 error norms is verified using smooth solutions to the two-dimensional stationary Poisson and incompressible Navier-Stokes equations. Numerical results for flow over a backward-facing step, steady flow past a circular cylinder, three-dimensional lid-driven cavity flow, and compressible buoyant flow inside a square enclosure are presented to demonstrate the predictive capability and robustness of the proposed formulation

  10. Demonstration of acoustic resonances in a cylindrical cavity applying the photoacoustic technique

    Science.gov (United States)

    Barreiro, N. L.; Vallespi, A. S.; Zajarevich, N. M.; Peuriot, A. L.; Slezak, V. B.

    2017-09-01

    In this work we present some experiments which can be performed in college or on the first courses of university to acquire knowledge about resonant acoustical phenomena in closed cavities in a tangible way, through experiments based on the photoacoustic effect in gases. This phenomenon consists in the generation of acoustic waves after optical excitation of an absorbing gas and further local heating of the non-absorbing surrounding gas by energy exchange through collisions between molecules of both species. Simple experiments, performed with daily live elements, can be very useful for teachers and students to get in touch with the phenomenon of acoustic resonances with the addition of concepts about light-matter interaction. The setups consist of the resonant cavity, the illumination source and the signal detection-acquisition scheme. In this paper a closed glass test tube is used as the resonant cavity and is filled with a mixture of nitrogen dioxide and air. The illumination is performed by a pulsed power LED modulated at different resonant frequencies of the cavity. A microphone inside the tube is connected to an oscilloscope which displays the photoacoustic signal. The LED is moved along the tube showing how different resonant modes can be excited.

  11. Transverse deflections in a cavity due to the short-range longitudinal wake

    International Nuclear Information System (INIS)

    Bane, K

    2003-01-01

    Consider an ultra-relativistic electron bunch passing through a (cylindrically symmetric) multi-cell linac cavity that is filled with fundamental mode rf. It is well known that this bunch--on entering the cavity--experiences a focusing kick, and--on exiting the cavity--a defocusing kick, even though the mode is cylindrically symmetric. The effects of these kicks in linacs tend to be significant only in low energy regions. Tracking computer programs such as MAD [1] and LIAR [2] include a simple model of these kicks, one based on calculations of W.H. Panofsky [3]. According to this model the effect is represented by two thin lenses positioned at the ends of the cavity, with the strength of the lenses dependent on the accelerating gradient in the cavity. However, a beam will itself excite wakefields that modify its energy gain in a cavity, a modification that depends also on longitudinal position within the bunch. The program LIAR extends Panofsky's rf kick model to include this modification to the effective gradient experienced by different parts of the beam. In this report we investigate how the wakefields affect the rf cavity kicks. In particular, we are interested in the case when the wakefields are a significant perturbation to the problem, such as when, for example, the beam traverses an empty cavity (one with no rf). In this report we have shown that one can calculate the transverse kicks when one knows the time-dependent variation of the longitudinal wake forces on axis. The variation in gradient due to wakefields, however, will in general differ from that due to normal rf acceleration. In particular, transients at the ends of structures, and--for constant gradient structures--an increase in gradient amplitude from beginning to end of the cavity, will mean that the model of focusing/defocusing edges, used for rf acceleration, will be inaccurate. Finally, we conclude that the method LIAR uses to treat the effect of rf focusing in the presence of wakefields on

  12. Creating Magic Squares.

    Science.gov (United States)

    Lyon, Betty Clayton

    1990-01-01

    One method of making magic squares using a prolongated square is illustrated. Discussed are third-order magic squares, fractional magic squares, fifth-order magic squares, decimal magic squares, and even magic squares. (CW)

  13. Acousto-optical interaction of surface acoustic and optical waves in a two-dimensional phoxonic crystal hetero-structure cavity.

    Science.gov (United States)

    Ma, Tian-Xue; Zou, Kui; Wang, Yue-Sheng; Zhang, Chuanzeng; Su, Xiao-Xing

    2014-11-17

    Phoxonic crystal is a promising material for manipulating sound and light simultaneously. In this paper, we theoretically demonstrate the propagation of acoustic and optical waves along the truncated surface of a two-dimensional square-latticed phoxonic crystal. Further, a phoxonic crystal hetero-structure cavity is proposed, which can simultaneously confine surface acoustic and optical waves. The interface motion and photoelastic effects are taken into account in the acousto-optical coupling. The results show obvious shifts in eigenfrequencies of the photonic cavity modes induced by different phononic cavity modes. The symmetry of the phononic cavity modes plays a more important role in the single-phonon exchange process than in the case of the multi-phonon exchange. Under the same deformation, the frequency shift of the photonic transverse electric mode is larger than that of the transverse magnetic mode.

  14. Three-dimensional stability, receptivity and sensitivity of non-Newtonian flows inside open cavities

    International Nuclear Information System (INIS)

    Citro, Vincenzo; Giannetti, Flavio; Pralits, Jan O

    2015-01-01

    We investigate the stability properties of flows over an open square cavity for fluids with shear-dependent viscosity. Analysis is carried out in context of the linear theory using a normal-mode decomposition. The incompressible Cauchy equations, with a Carreau viscosity model, are discretized with a finite-element method. The characteristics of direct and adjoint eigenmodes are analyzed and discussed in order to understand the receptivity features of the flow. Furthermore, we identify the regions of the flow that are more sensitive to spatially localized feedback by building a spatial map obtained from the product between the direct and adjoint eigenfunctions. Analysis shows that the first global linear instability of the steady flow is a steady or unsteady three-dimensionl bifurcation depending on the value of the power-law index n. The instability mechanism is always located inside the cavity and the linear stability results suggest a strong connection with the classical lid-driven cavity problem. (paper)

  15. Mirror-smooth surfaces and repair of defects in superconducting RF cavities by mechanical polishing

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, C. A. [Fermilab; Cooley, L. D. [Fermilab

    2012-11-22

    Mechanical techniques for polishing the inside surface of niobium superconducting radio-frequency (SRF) cavities have been systematically explored. By extending known techniques to fine polishing, mirror-like finishes were produced, with <15 nm RMS (root mean square) roughness over 1 mm2 scan area. This is an order of magnitude less than the typical roughness produced by the electropolishing of niobium cavities. The extended mechanical polishing (XMP) process was applied to several SRF cavities which exhibited equator defects that caused quench at <20 MV m-1 and were not improved by further electropolishing. Cavity optical inspection equipment verified the complete removal of these defects, and minor acid processing, which dulled the mirror finish, restored performance of the defective cells to the high gradients and quality factors measured for adjacent cells when tested with other harmonics. This innate repair feature of XMP could be used to increase manufacturing yield. Excellent superconducting properties resulted after initial process optimization, with quality factor Q of 3 × 1010 and accelerating gradient of 43 MV m-1 being attained for a single-cell TESLA cavity, which are both close to practical limits. Several repaired nine-cell cavities also attained Q > 8 × 109 at 35 MV m-1, which is the specification for the International Linear Collider. Future optimization of the process and pathways for eliminating requirements for acid processing are also discussed.

  16. Microleakage of three self-etch bonding agents in class 5 composite cavities

    Directory of Open Access Journals (Sweden)

    Saeed Nemati Anaraki

    2016-07-01

    Full Text Available Background and Aims: Microleakage is one of the most common problems in bonding systems, which cause different clinical shortcomings such as post operative sensitivity, marginal discoloration and pulp necrosis that can decrease those using bonding systems. The aim of this study was to compare the microleakage of three self etch bonding agents (generation 6 and 7 in class 5 composite cavities. Materials and Methods: In this experimental study, 30 facial class 5 cavities were prepared in 30 human premolar teeth which were freshly extracted for orthodontic purposes. Cl V cavities were prepared in 2*3*2 mm dimensions. Occlusal margins were in enamel and gingival ones in cementum and randomly divided into 3 groups of 10 each. Then the cavities were treated by clearhil SE Bond (Kuraray, Japan, G Bond (GC, Japan, and Opti Bond Solo Plus (Kerr, USA, according to the manufacturers’ insductions. Then the cavities were filled using Z100 resin composite. The specimens were then immersed in a 50% AgNo solution for 24 hrs. Then, the teeth were cut buccolingually to be evaluated for dye penetration with stereomicroscope. Data were analyzed using Kruskal-Wallis test. Results: This study revealed that Opti bond solo plus had type1 microleakage (dye penetration up to 1/3 of cavity in 80% of specimen, and type 4 microleakage (along axial wall in 10%. Clearfil SE bond had no leakage in 50%, type1 in 40% and type 2 (up to 2/3 of cavity in 10%. But there was no significant difference in the microleakage at the gingival margins between 3 groups (P>0.05. Conclusion: Clearfil SE Bond and G bond could prevent microleakage more effectively than that of Opti Bond Solo Plus on the occlusal margins. However, no difference in the microleakage on the gingival surfaces was found.

  17. Dynamics of water molecules in the active-site cavity of human cytochromes P450

    DEFF Research Database (Denmark)

    Rydberg, Patrik; Rod, Thomas Holm; Olsen, Lars

    2007-01-01

    We have studied the dynamics of water molecules in six crystal structures of four human cytochromes P450, 2A6, 2C8, 2C9, and 3A4, with molecular dynamics simulations. In the crystal structures, only a few water molecules are seen and the reported sizes of the active-site cavity vary a lot....... In the simulations, the cavities are completely filled with water molecules, although with approximately 20% lower density than in bulk water. The 2A6 protein differs from the other three in that it has a very small cavity with only two water molecules and no exchange with the surroundings. The other three proteins...... channels, through which there is a quite frequent exchange of water molecules (one molecule is exchanged every 30-200 ps), except in 2A6. Most of the channels are observed also in the crystal structures, but two to three channels in each protein open only during the simulations. There are no water...

  18. Investigation of fluids as filling of a biomimetic infrared sensor based on the infrared receptors of pyrophilous insects

    Science.gov (United States)

    Kahl, T.; Li, N.; Schmitz, H.; Bousack, H.

    2012-04-01

    The beetle Melanophila acuminata is highly dependent on forest fires. The burned wood serves as food for the larvae and the adults copulate on the burned areas to put their eggs in the freshly burned trees. To be able to detect forest fires from great distances the beetle developed a highly sensitive infrared receptor which works according to a photomechanical principle. The beetle has two pit organs, one on each lateral side, of which each houses around 70 dome shaped infrared receptors. These IR-receptors consist of a hard outer cuticular shell and an inner microfluidic core. When IR-radiation is absorbed, the pressure in the core increases due to the thermal expansion. This results in a deflection of a dendritic tip of a mechanosensitiv neuron which generates the signal. This biological principle was transferred into a new kind of un-cooled technical infrared receptor. To demonstrate the functional principle and the feasibility of this IR-sensor a macroscopic demonstrator sensor was build. It consisted of an inner fluid filled cavity (pressure chamber), an IR-transmissive window and a membrane. The deflection of the membrane due to the absorbed IR-energy was measured by a sensitive commercial capacitive sensor. In the experiments ethanol with added black ink, a mix of ethanol and glucose with additional absorber, air with additional absorber and water were used as fillings of the cavity and compared against each other. In order to get insights into the physics of the results of the experiments accompanying simulations using FEM methods and analytical calculations have been performed. The results showed that ethanol and air as fillings of the cavity caused the largest deflection of the membrane. Furthermore it turned out that the thermal expansion of the sensor housing material has an important influence. The comparison of the measured deflection with calculated deflections showed a good concordance.

  19. Using Squares to Sum Squares

    Science.gov (United States)

    DeTemple, Duane

    2010-01-01

    Purely combinatorial proofs are given for the sum of squares formula, 1[superscript 2] + 2[superscript 2] + ... + n[superscript 2] = n(n + 1) (2n + 1) / 6, and the sum of sums of squares formula, 1[superscript 2] + (1[superscript 2] + 2[superscript 2]) + ... + (1[superscript 2] + 2[superscript 2] + ... + n[superscript 2]) = n(n + 1)[superscript 2]…

  20. In-vitro comparison of micro-leakage between nanocomposite and microhybrid composite in class v cavities treated with the self-etch technique

    International Nuclear Information System (INIS)

    Mahvish, S.; Khan, F.R.

    2016-01-01

    Background: When a light cure composite resin is used to restore a class V lesion, certain stresses are generated at the tooth-restoration interface. If these stresses exceed the bond strength of the restorative material, microscopic gaps are formed which eventually cause micro-leakage at the tooth-restoration interface. The objective of the present study was to compare the micro-leakage values at the tooth-restoration interface using dye penetration method between a Nano filled and a Micro hybrid light cured composite resin in class V cavities using the self-etch technique. Methods: Sixty class V cavities were made coronal to the cemento-enamel junction in the extracted premolars. These were then randomly divided into two study groups. Group A: Self-etch; filled with P-60 (micro-hybrid) n=30. Group B: Self-etch; filled with Z-350 (nano-filled) n=30. Specimens were subjected to thermo-cycling at 5-55 degree C ± 2 degree C with a 30 seconds dwell time. After which they were stained with 2% methylene blue. Later, sectioned bucco-lingually and examined using a stereo microscope (magnification X4) at the occlusal, axial and gingival surfaces. Micro-leakage around the tooth-restoration interface was assessed by using the degree of dye penetration in millimetres. Results: There was 100% micro leakage seen at both the occlusal and gingival surfaces when using the P-60 composite. With the Z-350 composite 84% occlusal and 88% of the gingival surfaces exhibited micro-leakage. Conclusions: With respect to micro-leakage in class V cavities, Z-350 was found to be a superior restorative material compared to P-60 on the occlusal surface. Overall, there is no statistically significant difference in the micro-leakage exhibited by the two restorative materials in class V preparations subjected to self-etch protocol. (author)

  1. Space-time coupled spectral/hp least-squares finite element formulation for the incompressible Navier-Stokes equations

    International Nuclear Information System (INIS)

    Pontaza, J.P.; Reddy, J.N.

    2004-01-01

    We consider least-squares finite element models for the numerical solution of the non-stationary Navier-Stokes equations governing viscous incompressible fluid flows. The paper presents a formulation where the effects of space and time are coupled, resulting in a true space-time least-squares minimization procedure, as opposed to a space-time decoupled formulation where a least-squares minimization procedure is performed in space at each time step. The formulation is first presented for the linear advection-diffusion equation and then extended to the Navier-Stokes equations. The formulation has no time step stability restrictions and is spectrally accurate in both space and time. To allow the use of practical C 0 element expansions in the resulting finite element model, the Navier-Stokes equations are expressed as an equivalent set of first-order equations by introducing vorticity as an additional independent variable and the least-squares method is used to develop the finite element model of the governing equations. High-order element expansions are used to construct the discrete model. The discrete model thus obtained is linearized by Newton's method, resulting in a linear system of equations with a symmetric positive definite coefficient matrix that is solved in a fully coupled manner by a preconditioned conjugate gradient method in matrix-free form. Spectral convergence of the L 2 least-squares functional and L 2 error norms in space-time is verified using a smooth solution to the two-dimensional non-stationary incompressible Navier-Stokes equations. Numerical results are presented for impulsively started lid-driven cavity flow, oscillatory lid-driven cavity flow, transient flow over a backward-facing step, and flow around a circular cylinder; the results demonstrate the predictive capability and robustness of the proposed formulation. Even though the space-time coupled formulation is emphasized, we also present the formulation and numerical results for least-squares

  2. A Many-Atom Cavity QED System with Homogeneous Atom-Cavity Coupling

    OpenAIRE

    Lee, Jongmin; Vrijsen, Geert; Teper, Igor; Hosten, Onur; Kasevich, Mark A.

    2013-01-01

    We demonstrate a many-atom-cavity system with a high-finesse dual-wavelength standing wave cavity in which all participating rubidium atoms are nearly identically coupled to a 780-nm cavity mode. This homogeneous coupling is enforced by a one-dimensional optical lattice formed by the field of a 1560-nm cavity mode.

  3. Impact of detector-element active-area shape and fill factor on super-resolution

    Directory of Open Access Journals (Sweden)

    Russell Craig Hardie

    2015-05-01

    Full Text Available In many undersampled imaging systems, spatial integration from the individual detector elements is the dominant component of the system point spread function (PSF. Conventional focal plane arrays (FPAs utilize square detector elements with a nearly 100% fill factor, where fill factor is defined as the fraction of the detector element area that is active in light detection. A large fill factor is generally considered to be desirable because more photons are collected for a given pitch, and this leads to a higher signal-to-noise-ratio (SNR. However, the large active area works against super-resolution (SR image restoration by acting as an additional low pass filter in the overall PSF when modeled on the SR sampling grid. A high fill factor also tends to increase blurring from pixel cross-talk. In this paper, we study the impact of FPA detector-element shape and fill factor on SR. A detailed modulation transfer function analysis is provided along with a number of experimental results with both simulated data and real data acquired with a midwave infrared (MWIR imaging system. We demonstrate the potential advantage of low fill factor detector elements when combined with SR image restoration. Our results suggest that low fill factor circular detector elements may be the best choice. New video results are presented using robust adaptive Wiener filter SR processing applied to data from a commercial MWIR imaging system with both high and low detector element fill factors.

  4. Segmented trapped vortex cavity

    Science.gov (United States)

    Grammel, Jr., Leonard Paul (Inventor); Pennekamp, David Lance (Inventor); Winslow, Jr., Ralph Henry (Inventor)

    2010-01-01

    An annular trapped vortex cavity assembly segment comprising includes a cavity forward wall, a cavity aft wall, and a cavity radially outer wall there between defining a cavity segment therein. A cavity opening extends between the forward and aft walls at a radially inner end of the assembly segment. Radially spaced apart pluralities of air injection first and second holes extend through the forward and aft walls respectively. The segment may include first and second expansion joint features at distal first and second ends respectively of the segment. The segment may include a forward subcomponent including the cavity forward wall attached to an aft subcomponent including the cavity aft wall. The forward and aft subcomponents include forward and aft portions of the cavity radially outer wall respectively. A ring of the segments may be circumferentially disposed about an axis to form an annular segmented vortex cavity assembly.

  5. An analytic study on laminar film condensation along the interior surface of a cave-shaped cavity of a flat plate heat pipe

    International Nuclear Information System (INIS)

    Lee, Jin Sung; Kim, Tae Gyu; Park, Tae Sang; Kim, Choong Sik; Park, Chan Hoon

    2002-01-01

    An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ crit =3∼7%, Ψ crit =0.5∼1.3%, respectively, in the range of heat flux q = 5∼90kW/m 2

  6. Enlargement of Tuning Range in a Ferrite-Tuned Cavity Through Superposed Orthogonal and Parallel Magnetic Bias

    CERN Document Server

    Vollinger, C

    2013-01-01

    Conventional ferrite-tuned cavities operate either with bias fields that are orthogonal or parallel to the magnetic RF-field. For a cavity that tunes rapidly over an overall frequency range around 100-400 MHz with high Q, we use ferrite garnets exposed to an innovative new biasing method consisting of a superposition of perpendicular and parallel magnetic fields. This method leads to a significant enlargement of the high-Q cavity tuning range by defining an operation point close to the magnetic saturation and thus improving ferrite material behaviour. A further advantage of this technique is the fast tuning speed resulting from the fact that tuning is carried out either with pure parallel biasing, or together with a very small change of operating point from perpendicular bias. In this paper, several scaled test models of ferrite-filled resonators are shown; measurements on the set-ups are compared and discussed.

  7. Implosion of the small cavity and large cavity cannonball targets

    International Nuclear Information System (INIS)

    Nishihara, Katsunobu; Yamanaka, Chiyoe.

    1984-01-01

    Recent results of cannonball target implosion research are briefly reviewed with theoretical predictions for GEKKO XII experiments. The cannonball targets are classified into two types according to the cavity size ; small cavity and large cavity. The compression mechanisms of the two types are discussed. (author)

  8. Efficient Characterization of Protein Cavities within Molecular Simulation Trajectories: trj_cavity.

    Science.gov (United States)

    Paramo, Teresa; East, Alexandra; Garzón, Diana; Ulmschneider, Martin B; Bond, Peter J

    2014-05-13

    Protein cavities and tunnels are critical in determining phenomena such as ligand binding, molecular transport, and enzyme catalysis. Molecular dynamics (MD) simulations enable the exploration of the flexibility and conformational plasticity of protein cavities, extending the information available from static experimental structures relevant to, for example, drug design. Here, we present a new tool (trj_cavity) implemented within the GROMACS ( www.gromacs.org ) framework for the rapid identification and characterization of cavities detected within MD trajectories. trj_cavity is optimized for usability and computational efficiency and is applicable to the time-dependent analysis of any cavity topology, and optional specialized descriptors can be used to characterize, for example, protein channels. Its novel grid-based algorithm performs an efficient neighbor search whose calculation time is linear with system size, and a comparison of performance with other widely used cavity analysis programs reveals an orders-of-magnitude improvement in the computational cost. To demonstrate its potential for revealing novel mechanistic insights, trj_cavity has been used to analyze long-time scale simulation trajectories for three diverse protein cavity systems. This has helped to reveal, respectively, the lipid binding mechanism in the deep hydrophobic cavity of a soluble mite-allergen protein, Der p 2; a means for shuttling carbohydrates between the surface-exposed substrate-binding and catalytic pockets of a multidomain, membrane-proximal pullulanase, PulA; and the structural basis for selectivity in the transmembrane pore of a voltage-gated sodium channel (NavMs), embedded within a lipid bilayer environment. trj_cavity is available for download under an open-source license ( http://sourceforge.net/projects/trjcavity ). A simplified, GROMACS-independent version may also be compiled.

  9. Numerical simulation of mould filling process for pressure plate and valve handle in LFC

    Directory of Open Access Journals (Sweden)

    Jiang Junxia

    2010-11-01

    Full Text Available In lost foam casting (LFC, the distribution of polymer beads during the bead filling process is not uniform, and the collision between polymer beads determines the distribution of two-phase flow of gas and solid. The interaction between the gas and solid phases reveals as coupling effect of the force that gas exerts on particles or vice versa, or that among particles. The gas-solid flow in filling process is nonlinearity, which makes the coupling effect an essential point to carry out a simulation properly. Therefore, information of each particle’s motion is important for acquiring the law of filling process. In bead filling process, compressed air is pressed into mold cavity, and discharged from gas vent, creating a pressure difference between outer and inner space near the gas vent. This pressure difference directly changes the spatial distribution and motion trace of gas and solid phases. In this paper, Discrete Element Method (DEM and Computational Fluid Dynamics (CFD are employed to simulate the fluid dynamic character based on Newton’s Third Law of Motion. The simulation results of some casting products such as pressure plate and valve handle are compared with the result obtained from practical experiment in order to test the feasibility of DEM. The comparison shows that this DEM method can be a very promising tool in the mould filling simulation of beads’ movement.

  10. Large scale particle image velocimetry with helium filled soap bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Bosbach, Johannes; Kuehn, Matthias; Wagner, Claus [German Aerospace Center (DLR), Institute of Aerodynamics and Flow Technology, Goettingen (Germany)

    2009-03-15

    The application of particle image velocimetry (PIV) to measurement of flows on large scales is a challenging necessity especially for the investigation of convective air flows. Combining helium filled soap bubbles as tracer particles with high power quality switched solid state lasers as light sources allows conducting PIV on scales of the order of several square meters. The technique was applied to mixed convection in a full scale double aisle aircraft cabin mock-up for validation of computational fluid dynamics simulations. (orig.)

  11. Large scale particle image velocimetry with helium filled soap bubbles

    Science.gov (United States)

    Bosbach, Johannes; Kühn, Matthias; Wagner, Claus

    2009-03-01

    The application of Particle Image Velocimetry (PIV) to measurement of flows on large scales is a challenging necessity especially for the investigation of convective air flows. Combining helium filled soap bubbles as tracer particles with high power quality switched solid state lasers as light sources allows conducting PIV on scales of the order of several square meters. The technique was applied to mixed convection in a full scale double aisle aircraft cabin mock-up for validation of Computational Fluid Dynamics simulations.

  12. Efficiency of polymerization of bulk-fill composite resins: a systematic review.

    Science.gov (United States)

    Reis, André Figueiredo; Vestphal, Mariana; Amaral, Roberto Cesar do; Rodrigues, José Augusto; Roulet, Jean-François; Roscoe, Marina Guimarães

    2017-08-28

    This systematic review assessed the literature to evaluate the efficiency of polymerization of bulk-fill composite resins at 4 mm restoration depth. PubMed, Cochrane, Scopus and Web of Science databases were searched with no restrictions on year, publication status, or article's language. Selection criteria included studies that evaluated bulk-fill composite resin when inserted in a minimum thickness of 4 mm, followed by curing according to the manufacturers' instructions; presented sound statistical data; and comparison with a control group and/or a reference measurement of quality of polymerization. The evidence level was evaluated by qualitative scoring system and classified as high-, moderate- and low- evidence level. A total of 534 articles were retrieved in the initial search. After the review process, only 10 full-text articles met the inclusion criteria. Most articles included (80%) were classified as high evidence level. Among several techniques, microhardness was the most frequently method performed by the studies included in this systematic review. Irrespective to the "in vitro" method performed, bulk fill RBCs were partially likely to fulfill the important requirement regarding properly curing in 4 mm of cavity depth measured by depth of cure and / or degree of conversion. In general, low viscosities BFCs performed better regarding polymerization efficiency compared to the high viscosities BFCs.

  13. The change of electric potentials in the oral cavity after application of extremely low frequency pulsed magnetic field

    Directory of Open Access Journals (Sweden)

    Piotr Skomro

    2012-12-01

    Full Text Available Electric potentials occurring in the oral cavity deserve attention as they may cause various diseases and subjective feelings, which are very difficult to treat. The aim of this study was to evaluate the electric potentials within the oral cavity in patients with metal fillings and metal prosthetic restorations, after using a pulsed electromagnetic field. The study was carried out on 84 patients. The Viofor JPS Classic device was used in the treatment. It generates a pulsed electromagnetic field with low induction of the extremely low frequency (ELF range. Average values of electric potentials in the preliminary test were about the same in both groups; they were 148.8 mV and 145.5 mV. After another appliance of ELF fields there was found a steady decline in the average value of electric potentials in the study group. This decrease was statistically highly significant, while mean values of electric potentials in the control group were characterized by a slightly upward tendency. The obtained statistically significant reduction of electric potentials in the oral cavity of patients having metal fillings and metal prosthetic restorations, after application of the Viofor JPS Classic device, implies a huge impact of ELF pulsed electromagnetic field on inhibition of electrochemical processes, as well as on inhibition of dental alloy corrosion. 

  14. Selection and specification criteria for fills for cut-and-fill mining

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, E. G.

    1980-05-15

    Because of significant differences in placement and loading conditions, the ideal fill material for a cut-and-fill operation has different characteristics to those for a fill for a filled open stoping operation. The differing requirements of the two mining operations must be understood and accounted for in establishing fill selection and specification criteria. Within the paper, aspects of the particular requirements of cut-and-fill mining are analyzed and related to the specific fill tests and properties required. Emphasis is placed upon the role of fill in ground support, though this cannot be isolated from overall fill performance. Where appropriate, test data are introduced and areas requiring continuing research highlighted.

  15. High Pressure Gas Filled RF Cavity Beam Test at the Fermilab MuCool Test Area

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [Illinois Inst. of Technology, Chicago, IL (United States)

    2013-05-01

    The high energy physics community is continually looking to push the limits with respect to the energy and luminosity of particle accelerators. In the realm of leptons, only electron colliders have been built to date. Compared to hadrons, electrons lose a large amount of energy when accelerated in a ring through synchrotron radiation. A solution to this problem is to build long, straight accelerators for electrons, which has been done with great success. With a new generation of lepton colliders being conceived, building longer, more powerful accelerators is not the most enticing option. Muons have been proposed as an alternative particle to electrons. Muons lose less energy to synchrotron radiation and a Muon Collider can provide luminosity within a much smaller energy range than a comparable electron collider. This allows a circular collider to be built with higher attainable energy than any present electron collider. As part of the accelerator, but separate from the collider, it would also be possible to allow the muons to decay to study neutrinos. The possibility of a high energy, high luminosity muon collider and an abundant, precise source of neutrinos is an attractive one. The technological challenges of building a muon accelerator are many and diverse. Because the muon is an unstable particle, a muon beam must be cooled and accelerated to the desired energy within a short amount of time. This requirement places strict requisites on the type of acceleration and focusing that can be used. Muons are generated as tertiary beams with a huge phase space, so strong magnetic fields are required to capture and focus them. Radio frequency (RF) cavities are needed to capture, bunch and accelerate the muons. Unfortunately, traditional vacuum RF cavities have been shown to break down in the magnetic fields necessary for capture and focusing.

  16. High-order integral equation methods for problems of scattering by bumps and cavities on half-planes.

    Science.gov (United States)

    Pérez-Arancibia, Carlos; Bruno, Oscar P

    2014-08-01

    This paper presents high-order integral equation methods for the evaluation of electromagnetic wave scattering by dielectric bumps and dielectric cavities on perfectly conducting or dielectric half-planes. In detail, the algorithms introduced in this paper apply to eight classical scattering problems, namely, scattering by a dielectric bump on a perfectly conducting or a dielectric half-plane, and scattering by a filled, overfilled, or void dielectric cavity on a perfectly conducting or a dielectric half-plane. In all cases field representations based on single-layer potentials for appropriately chosen Green functions are used. The numerical far fields and near fields exhibit excellent convergence as discretizations are refined-even at and around points where singular fields and infinite currents exist.

  17. Technical Quality of Root Fillings Performed by Undergraduate Students: A Radiographic Study

    Directory of Open Access Journals (Sweden)

    Tatjana Vukadinov

    2014-01-01

    Full Text Available Aim. The aim of this study was to evaluate the radiographic technical quality of endodontic treatment performed by undergraduate students at the School of Dentistry, Faculty of Medicine, University of Novi Sad, Serbia. Materials and Methods. Electronic records of 220 patients treated by final-year undergraduate students during the school year 2011/2012 were examined, and the final sample consisted of 212 patients, 322 teeth, and 565 root canals. The criteria for overall radiographic adequacy of root canal fillings were defined as the presence of adequate length and density and absence of iatrogenic errors (ledge, fractured instrument, untreated canal, and apical transportation. Chi-square test was used to determine statistical significance between different parameters. Results. Adequate root canal fillings were found in 74.22% of the teeth. The percentage of root fillings with adequate length and density was 89.73% and 92.6%, respectively. Fractured instruments and ledges were present in 16 root canals (2.8%, while the presence of missed canal and apical transportation was observed in 2 cases, each (0.3%. Conclusions. Overall, the technical quality of root canal fillings performed by undergraduate students was satisfactory.

  18. Fractal apertures in waveguides, conducting screens and cavities analysis and design

    CERN Document Server

    Ghosh, Basudeb; Kartikeyan, M V

    2014-01-01

    This book deals with the design and analysis of fractal apertures in waveguides, conducting screens and cavities using numerical electromagnetics and field-solvers. The aim is to obtain design solutions with improved accuracy for a wide range of applications. To achieve this goal, a few diverse problems are considered. The book is organized with adequate space dedicated for the design and analysis of fractal apertures in waveguides, conducting screens, and cavities, microwave/millimeter wave applications followed by detailed case-study problems to infuse better insight and understanding of the subject. Finally, summaries and suggestions are given for future work. Fractal geometries were widely used in electromagnetics, specifically for antennas and frequency selective surfaces (FSS). The self-similarity of fractal geometry gives rise to a multiband response, whereas the  space-filling nature of the fractal geometries makes it an efficient element in antenna and FSS unit cell miniaturization. Until now, no e...

  19. Red-cockaded woodpecker nest-cavity selection: relationships with cavity age and resin production

    Science.gov (United States)

    Richard N. Conner; Daniel Saenz; D. Craig Rudolph; William G. Ross; David L. Kulhavy

    1998-01-01

    The authors evaluated selection of nest sites by male red-cockaded woodpeckers (Picoides borealis) in Texas relative to the age of the cavity when only cavities excavated by the woodpeckers were available and when both naturally excavated cavities and artificial cavities were available. They also evaluated nest-cavity selection relative to the ability of naturally...

  20. Finite-difference numerical simulations of underground explosion cavity decoupling

    Science.gov (United States)

    Aldridge, D. F.; Preston, L. A.; Jensen, R. P.

    2012-12-01

    Earth models containing a significant portion of ideal fluid (e.g., air and/or water) are of increasing interest in seismic wave propagation simulations. Examples include a marine model with a thick water layer, and a land model with air overlying a rugged topographic surface. The atmospheric infrasound community is currently interested in coupled seismic-acoustic propagation of low-frequency signals over long ranges (~tens to ~hundreds of kilometers). Also, accurate and efficient numerical treatment of models containing underground air-filled voids (caves, caverns, tunnels, subterranean man-made facilities) is essential. In support of the Source Physics Experiment (SPE) conducted at the Nevada National Security Site (NNSS), we are developing a numerical algorithm for simulating coupled seismic and acoustic wave propagation in mixed solid/fluid media. Solution methodology involves explicit, time-domain, finite-differencing of the elastodynamic velocity-stress partial differential system on a three-dimensional staggered spatial grid. Conditional logic is used to avoid shear stress updating within the fluid zones; this approach leads to computational efficiency gains for models containing a significant proportion of ideal fluid. Numerical stability and accuracy are maintained at air/rock interfaces (where the contrast in mass density is on the order of 1 to 2000) via a finite-difference operator "order switching" formalism. The fourth-order spatial FD operator used throughout the bulk of the earth model is reduced to second-order in the immediate vicinity of a high-contrast interface. Current modeling efforts are oriented toward quantifying the amount of atmospheric infrasound energy generated by various underground seismic sources (explosions and earthquakes). Source depth and orientation, and surface topography play obvious roles. The cavity decoupling problem, where an explosion is detonated within an air-filled void, is of special interest. A point explosion

  1. Dental cavities

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001055.htm Dental cavities To use the sharing features on this page, please enable JavaScript. Dental cavities are holes (or structural damage) in the ...

  2. Iron-filled multi-walled carbon nanotubes for terahertz applications: effects of interfacial polarization, screening and anisotropy

    Science.gov (United States)

    Sedelnikova, O. V.; Korovin, E. Yu; Dorozhkin, K. V.; Kanygin, M. A.; Arkhipov, V. E.; Shubin, Yu V.; Zhuravlev, V. A.; Suslyaev, V. I.; Bulusheva, L. G.; Okotrub, A. V.

    2018-04-01

    Interface interactions in multicomponent nanoparticles can affect electromagnetic properties of an absorbing system. In this work, we investigate the electromagnetic response of multi-walled carbon nanotubes (MWCNTs) filled with iron-containing nanoparticles (ICNs) in the terahertz frequency range. MWCNTs with different iron content have been synthesized by aerosol-assisted catalytic chemical vapour deposition method from toluene containing a certain quantity of ferrocene used as a catalyst. According to the x-ray diffraction analysis, encapsulated ICNs were mainly in the form of iron carbide. Thin composite films were prepared from the iron-filled MWCNTs and polymethylmethacrylate (PMMA) by casting and stretching methods. The composites showed an enhanced permittivity and anisotropy in the transmittance spectra when iron content increased. This behaviour was related to the mechanism based on electrical conductivity and polarization of ICNs and ICN/MWCNT interfaces. Since terahertz field penetrates inside MWCNTs, the filling of their cavities can be a way of varying the electromagnetic properties of MWCNT-containing composites.

  3. Deactivation of nuclear explosions cavities in the salt domes by freezing method

    International Nuclear Information System (INIS)

    Belyashov, D.N.; Mokhov, V.A.; Murzadilov, T.D.

    1998-01-01

    I. There is a lot of negative consequences of underground nuclear explosions, conducted for creating some cavities of the gas condensate saving at the Azgir site and Karachaganak deposit. Some of them are radioactivity escape, ground pollution, underground water pollution, as result of depressurization and irrigation of cavities. Besides that there are dissolution of infected salt, displacement of brine from the cavities. Existing prolonged exchanges of rock-salt, brines and water can be accompanied by accumulation and throw outing of free chlorine and hydrogen with hydrochloric acid formation, ('white fog' of Azgir site). These questions demand supplementary researches. 2. It is known that more dangerous fission fragments are 9 0S r and 1 31C s, with half life periods equaled 27.7 and 30.3. Duration of their existence determines a period of an object danger. Radionuclide migration come with rock dispersion or with their concentration on the different physical, chemical, including sorptive, barriers on the way of radioactive water displacement. 3. The task of prevention of negative consequences is to save the forms and sizes of cavities, to immobilize the radioactive fluid's in the cavities and closed zone for the half-life time of the main nuclide mass. 4. Solving the task by laying of empty space with hard materials (concrete, rock) demand of big expenses because of cavities size, occurrence depth (850-900 m), high value of materials, their processing and transportation. The problem to render harmless and to utilize of displacing radioactive brines is not solved yet. 5, Freezing of flooding cavities appears to be an alternative, which allows to fill the space by hard ice and to less the moving of radioactive brines into the rocks around the cavities, and, what is more important, along the bore-holes above the cavities, blocking the radionuclides moving into the fractured rocks. This process divides onto 2 stages: (1) freezing with organizing of intensive heat

  4. Superconducting TESLA cavities

    Directory of Open Access Journals (Sweden)

    B. Aune

    2000-09-01

    Full Text Available The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of E_{acc}≥25 MV/m at a quality factor Q_{0}≥5×10^{9}. The design goal for the cavities of the TESLA Test Facility (TTF linac was set to the more moderate value of E_{acc}≥15 MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q_{0}=5×10^{9} was measured to be 20.1±6.2 MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities, additional quality control measures were introduced, in particular, an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at Q_{0}=5×10^{9} amounts to 25.0±3.2 MV/m with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication, and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing research and development towards higher gradients is briefly addressed.

  5. A new approach for the validation of filling simulations in micro injection moulding

    DEFF Research Database (Denmark)

    Gava, Alberto; Tosello, Guido; Lucchetta, Giovanni

    2007-01-01

    In manufacturing polymer micro products, numerical simulations are used with the same purposes as in conventional injection moulding, mainly the optimization of micro components design, the optimization of process parameters and the decrease of production costs. Dedicated simulations softwares fail...... to be improved. The main objective of this work is to evaluate whether the present numerical codes are suitable to characterize melt flow patterns in a micro cavity. In order to test the accuracy of the software, real and simulated experiments were performed and used to investigate the filling of a micro moulded...

  6. Sealing ability of MTA, CPM, and MBPc as root-end filling materials: a bacterial leakage study.

    Science.gov (United States)

    Medeiros, Paulo Leal; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Torres, Sérgio Aparecido; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Marciano, Marina Angélica

    2016-04-01

    Objectives To evaluate the sealing ability of three root-end filling materials (white MTA, CPM, and MBPc) using an Enterococcus faecalis leakage model. Material and Methods Seventy single-root extracted human teeth were instrumented and root-ends were resected to prepare 3 mm depth cavities. Root-end preparations were filled with white MTA, CPM, and MBPc cements. Enterococcus faecalis was coronally introduced and the apical portion was immersed in BHI culture medium with phenol red indicator. The bacterial leakage was monitored every 24 h for 4 weeks. The statistical analysis was performed using the Wilcoxon-Gehan test (pCPM and the other groups. Conclusions The epoxy resin-based cement MBPc had lower bacterial leakage compared with the calcium silicate-based cements MTA and CPM.

  7. Knowledge and risk perception of oral cavity and oropharyngeal cancer among non-medical university students.

    Science.gov (United States)

    Osazuwa-Peters, Nosayaba; Tutlam, Nhial T

    2016-01-28

    To assess non-medical university students' knowledge and perceived risk of developing oral cavity and oropharyngeal cancer. A cross-sectional survey was conducted among non-medical students of a private Midwestern university in the United States in May 2012. Questionnaire assessed demographic information and contained 21 previously validated questions regarding knowledge and perceived risk of developing oral cavity and oropharyngeal cancer. Knowledge scale was categorized into low and high. Risk level was estimated based on smoking, drinking, and sexual habits. Bivariate associations between continuous and categorical variables were assessed using Pearson correlation and Chi-square tests, respectively. The response rate was 87% (100 out of 115 students approached). Eighty-one percent (81%) had low oral cavity and oropharyngeal cancer knowledge; and only 2% perceived that their oral cavity and oropharyngeal cancer risk was high. Risk perception was negatively correlated with age at sexual debut, r (64) = -0.26, p = 0.037; one-way ANOVA showed a marginally significant association between risk perception and number of sexual partners, F(4, 60) = 2.48, p = 0.05. There was no significant association between knowledge and perception of risk; however, oral cavity and oropharyngeal cancer knowledge was significantly associated with frequency of prevention of STDs (p risk perception is low among this student population. Since oral cavity and oropharyngeal cancer incidence is increasingly shifting towards younger adults, interventions must be tailored to this group in order to improve prevention and control.

  8. Reynolds number and end-wall effects on a lid-driven cavity flow

    International Nuclear Information System (INIS)

    Prasad, A.K.; Koseff, J.R.

    1989-01-01

    A series of experiments has been conducted in a lid-driven cavity of square cross section (depth = width = 150 mm) for Reynolds numbers (Re, based on lid speed and cavity width) between 3200 and 10 000, and spanwise aspect ratios (SAR) between 0.25:1 and 1:1. Flow visualization using polystyrene beads and two-dimensional laser-Doppler anemometer (LDA) measurements have shed new light on the momentum transfer processes within the cavity. This paper focuses on the variation, with Re and SAR, of the mean and the rms velocities profiles, as well as the /similar to/(U'V') profile, along the horizontal and vertical centerlines in the symmetry plane. In addition, the contribution of the large-scale ''organized structures,'' and the high-frequency ''turbulent'' velocity fluctuations to the total rms is examined. At low Re, the organized structures account for most of the energy contained in the flow irrespective of SAR. As the Re increases, however, so does the energy content of the higher frequency fluctuations. This trend is not independent of SAR; a reduction in the SAR causes the ''organized structures'' to again become more evident

  9. A broad-band (0.2-8 MHz) multiple-harmonic VITROVAC-filled acceleration structure

    Energy Technology Data Exchange (ETDEWEB)

    Ausset, P.; Charruau, G.; De Menezes, D.; Fougeron, C. [Laboratoire National Saturne, Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France); Etzkorn, F.J.; Papureanu, S.; Schnase, A.; Meuth, H. [Forschungszentrum Juelich GmbH (Germany)

    1994-12-31

    Higher or multiple-harmonic acceleration drives in synchrotrons are desirable, when passing the transition point, applying stochastic cooling on a bunched beam, or for many other longitudinal beam manipulations, as bunch stretching or compression. As proof-of-principle, virtually arbitrary, digitally synthesized voltage waveforms, employing contents up to fourth harmonic in the range 0.2-8 MHz, could be generated at the gap of one single (symmetric re-entrant) cavity, filled with discs of the novel ferritic amorphous metal VITROVAC of VAC, Hanau. A 10 kW amplifier produces voltages in the kV-range. As relevant examples, we achieved a flat-top waveform suitable for the transition (+27 deg, 10{sup -3} max. error), a fourth-order flattened bucket for bunched-beam cooling, and a harmonic bucket with linear restoring force. The compact cavity system should be well suited for any proton or heavy ion device operating in this frequency range, and therapy-oriented rings. (author). 9 refs., 6 figs.

  10. A broad-band (0.2-8 MHz) multiple-harmonic VITROVAC-filled acceleration structure

    International Nuclear Information System (INIS)

    Ausset, P.; Charruau, G.; De Menezes, D.; Fougeron, C.; Etzkorn, F.J.; Papureanu, S.; Schnase, A.; Meuth, H.

    1994-01-01

    Higher or multiple-harmonic acceleration drives in synchrotrons are desirable, when passing the transition point, applying stochastic cooling on a bunched beam, or for many other longitudinal beam manipulations, as bunch stretching or compression. As proof-of-principle, virtually arbitrary, digitally synthesized voltage waveforms, employing contents up to fourth harmonic in the range 0.2-8 MHz, could be generated at the gap of one single (symmetric re-entrant) cavity, filled with discs of the novel ferritic amorphous metal VITROVAC of VAC, Hanau. A 10 kW amplifier produces voltages in the kV-range. As relevant examples, we achieved a flat-top waveform suitable for the transition (+27 deg, 10 -3 max. error), a fourth-order flattened bucket for bunched-beam cooling, and a harmonic bucket with linear restoring force. The compact cavity system should be well suited for any proton or heavy ion device operating in this frequency range, and therapy-oriented rings. (author). 9 refs., 6 figs

  11. Wakefield and RF Kicks Due to Coupler Asymmetry in TESLA-Type Accelerating Cavities

    International Nuclear Information System (INIS)

    Bane, K

    2008-01-01

    In a future linear collider, such as the International Linear Collider (ILC), trains of high current, low emittance bunches will be accelerated in a linac before colliding at the interaction point. Asymmetries in the accelerating cavities of the linac will generate fields that will kick the beam transversely and degrade the beam emittance and thus the collider performance. In the main linac of the ILC, which is filled with TESLA-type superconducting cavities, it is the fundamental (FM) and higher mode (HM) couplers that are asymmetric and thus the source of such kicks. The kicks are of two types: one, due to (the asymmetry in) the fundamental RF fields and the other, due to transverse wakefields that are generated by the beam even when it is on axis. In this report we calculate the strength of these kicks and estimate their effect on the ILC beam. The TESLA cavity comprises nine cells, one HM coupler in the upstream end, and one (identical, though rotated) HM coupler and one FM coupler in the downstream end (for their shapes and location see Figs. 1, 2) [1]. The cavity is 1.1 m long, the iris radius 35 mm, and the coupler beam pipe radius 39 mm. Note that the couplers reach closer to the axis than the irises, down to a distance of 30 mm

  12. Study of the effect of loop inductance on the RF transmission line to cavity coupling coefficient

    International Nuclear Information System (INIS)

    Lal, Shankar; Pant, K. K.

    2016-01-01

    Coupling of RF power is an important aspect in the design and development of RF accelerating structures. RF power coupling employing coupler loops has the advantage of tunability of β, the transmission line to cavity coupling coefficient. Analytical expressions available in literature for determination of size of the coupler loop using Faraday’s law of induction show reasonably good agreement with experimentally measured values of β below critical coupling (β ≤ 1) but show large deviation with experimentally measured values and predictions by simulations for higher values of β. In actual accelerator application, many RF cavities need to be over-coupled with β > 1 for reasons of beam loading compensation, reduction of cavity filling time, etc. This paper discusses a modified analytical formulation by including the effect of loop inductance in the determination of loop size for any desired coupling coefficient. The analytical formulation shows good agreement with 3D simulations and with experimentally measured values. It has been successfully qualified by the design and development of power coupler loops for two 476 MHz pre-buncher RF cavities, which have successfully been conditioned at rated power levels using these coupler loops.

  13. Numerical investigation of pure mixed convection in a ferrofluid-filled lid-driven cavity for different heater configurations

    Directory of Open Access Journals (Sweden)

    Khan Md. Rabbi

    2016-03-01

    Full Text Available Mixed convection has been a center point of attraction to the heat transfer engineers for many years. Here, pure mixed convection analysis in cavity is carried out for two different geometric heater configurations under externally applied magnetic field. Ferrofluid (Fe3O4–water is considered as working fluid and modeled as single phase fluid. The heaters at the bottom wall are kept at constant high temperature while vertical side walls are adiabatic. The top wall is moving at a constant velocity in both geometric configurations and is kept at constant low temperature. Galerkin weighted residuals method of finite element analysis is implemented to solve the governing equations. The analysis has been carried out for a wide range of Richardson number (Ri = 0.1–10, Reynolds number (Re = 100–500, Hartmann number (Ha = 0–100 and solid volume fraction (φ = 0–0.15 of ferrofluid. The overall heat transfer performance for both the configurations is quantitatively investigated by average Nusselt number at the heated boundary wall. It is observed that higher Ri enhances the heat transfer rate, although higher Ha decreases heat transfer rate. Moreover, at higher Ri and lower Ha, semi-circular notched cavity shows significantly better (more than 30% heat transfer rate.

  14. Effects of cavity size on the control of transonic internal flow around a biconvex circular arc airfoil

    Science.gov (United States)

    Rahman, M. Mostaqur; Hasan, A. B. M. Toufique; Rabbi, M. S.

    2017-06-01

    In transonic flow conditions, self-sustained shock wave oscillation on biconvex airfoils is initiated by the complex shock wave boundary layer interaction which is frequently observed in several modern internal aeronautical applications such as inturbine cascades, compressor blades, butterfly valves, fans, nozzles, diffusers and so on. Shock wave boundary layer interaction often generates serious problems such as unsteady boundary layer separation, self-excited shock waveoscillation with large pressure fluctuations, buffeting excitations, aeroacoustic noise, nonsynchronous vibration, high cycle fatigue failure and intense drag rise. Recently, the control of the self-excited shock oscillation around an airfoil using passive control techniques is getting intense interest. Among the passive means, control using open cavity has found promising. In this study, the effect of cavity size on the control of self-sustained shock oscillation was investigated numerically. The present computations are validated with available experimental results. The results showed that the average root mean square (RMS) of pressure oscillation around the airfoil with open cavity has reduced significantly when compared to airfoil without cavity (clean airfoil).

  15. Cavity quantum electrodynamics

    International Nuclear Information System (INIS)

    Walther, Herbert; Varcoe, Benjamin T H; Englert, Berthold-Georg; Becker, Thomas

    2006-01-01

    This paper reviews the work on cavity quantum electrodynamics of free atoms. In recent years, cavity experiments have also been conducted on a variety of solid-state systems resulting in many interesting applications, of which microlasers, photon bandgap structures and quantum dot structures in cavities are outstanding examples. Although these phenomena and systems are very interesting, discussion is limited here to free atoms and mostly single atoms because these systems exhibit clean quantum phenomena and are not disturbed by a variety of other effects. At the centre of our review is the work on the one-atom maser, but we also give a survey of the entire field, using free atoms in order to show the large variety of problems dealt with. The cavity interaction can be separated into two main regimes: the weak coupling in cavity or cavity-like structures with low quality factors Q and the strong coupling when high-Q cavities are involved. The weak coupling leads to modification of spontaneous transitions and level shifts, whereas the strong coupling enables one to observe a periodic exchange of photons between atoms and the radiation field. In this case, atoms and photons are entangled, this being the basis for a variety of phenomena observed, some of them leading to interesting applications in quantum information processing. The cavity experiments with free atoms reached a new domain with the advent of experiments in the visible spectral region. A review on recent achievements in this area is also given

  16. Compensating microphonics in SRF cavities to ensure beam stability for future free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel

    2008-07-21

    In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02 in phase and up to 1.10{sup -4} in amplitude. For the planned BESSY-FEL it is envisaged to operate 144 superconducting 1.3 GHz cavities of the 2.3 GeV driver linac in continuous wave mode and at a low beam current. The cavity resonance comprises a very narrow bandwidth of the order of tens of Hertz. Such cavities have been characterized under accelerator like conditions in the HoBiCaT test facility. It was possible to measure the error sources affecting the field stability in continuous wave (CW) operation. Microphonics, the main error source for a mechanical detuning of the cavities, lead to an average fluctuation of the cavity resonance of 1-5 Hz rms. Furthermore, the static and dynamic Lorentz force detuning and the helium pressure dependance of the cavity resonance have been measured. Single cavity RF control and linac bunch-to-bunch longitudinal phase space modeling containing the measured properties showed, that it is advisable to find means to minimize the microphonics detuning by mechanical tuning. Thus, several fast tuning systems have been tested for CW operation. These tuners consist of a motor driven lever for slow and coarse tuning and a piezo that is integrated into the tuner support for fast and fine tuning. Regarding the analysis of the detuning spectrum an adaptive feedforward method based on the least-mean-square filter algorithm has been developed for fast cavity tuning. A detuning compensation between a factor of two and up to a factor of seven has been achieved. Modeling the complete system including the fast tuning scheme, showed that the requirements of the BESSY-FEL are attainable. (orig.)

  17. Compensating microphonics in SRF cavities to ensure beam stability for future free electron lasers

    International Nuclear Information System (INIS)

    Neumann, Axel

    2008-01-01

    In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02 in phase and up to 1.10 -4 in amplitude. For the planned BESSY-FEL it is envisaged to operate 144 superconducting 1.3 GHz cavities of the 2.3 GeV driver linac in continuous wave mode and at a low beam current. The cavity resonance comprises a very narrow bandwidth of the order of tens of Hertz. Such cavities have been characterized under accelerator like conditions in the HoBiCaT test facility. It was possible to measure the error sources affecting the field stability in continuous wave (CW) operation. Microphonics, the main error source for a mechanical detuning of the cavities, lead to an average fluctuation of the cavity resonance of 1-5 Hz rms. Furthermore, the static and dynamic Lorentz force detuning and the helium pressure dependance of the cavity resonance have been measured. Single cavity RF control and linac bunch-to-bunch longitudinal phase space modeling containing the measured properties showed, that it is advisable to find means to minimize the microphonics detuning by mechanical tuning. Thus, several fast tuning systems have been tested for CW operation. These tuners consist of a motor driven lever for slow and coarse tuning and a piezo that is integrated into the tuner support for fast and fine tuning. Regarding the analysis of the detuning spectrum an adaptive feedforward method based on the least-mean-square filter algorithm has been developed for fast cavity tuning. A detuning compensation between a factor of two and up to a factor of seven has been achieved. Modeling the complete system including the fast tuning scheme, showed that the requirements of the BESSY-FEL are attainable. (orig.)

  18. Experimental analysis of energy absorption behaviour of Al-tube filled with pumice lightweight concrete under axial loading condition

    Science.gov (United States)

    Rajak, D. K.; Deshpande, P. G.; Kumaraswamidhas, L. A.

    2017-08-01

    This Paper aimed at experimental investigation of compressive behaviour of square tube filled with pumice lightweight concrete (PLC). Square section of 20×20×30 mm is investigated, which is the backbone structure. The compression deformation result shows the better folding mechanism, displacement value, and energy absorption. PLC concrete filled with aluminium thin-wall tubes has been revealed superior energy absorption capacity (EAC) under low strain rate at room temperature. Superior EAC resulted as a result of mutual deformation benefit between aluminium section and PLC is also analysed. PLC was characterised by Fourier Transform Infrared (FTIR) and Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Spectrometry (EDX) analysis for better understanding of material behaviour. Individual and comparative load bearing graphs is logged for better prospective of analysing. Novel approach aimed at validation of porous lightweight concrete for better lightweight EA filler material.

  19. The cavity-nest ant Temnothorax crassispinus prefers larger nests.

    Science.gov (United States)

    Mitrus, S

    Colonies of the ant Temnothorax crassispinus inhabit mostly cavities in wood and hollow acorns. Typically in the field, nest sites that can be used by the ant are a limited resource. In a field experiment, it was investigated whether the ants prefer a specific size of nest, when different ones are available. In July 2011, a total of 160 artificial nests were placed in a beech-pine forest. Four artificial nests (pieces of wood with volume cavities, ca 415, 605, 730, and 980 mm 3 , respectively) were located on each square meter of the experimental plot. One year later, shortly before the emergence of new sexuals, the nests were collected. In July 2012, colonies inhabited more frequently bigger nests. Among queenright colonies, the ones which inhabited bigger nests had more workers. However, there was no relationship between volume of nest and number of workers for queenless colonies. Queenright colonies from bigger nests produced more sexual individuals, but there was no correlation between number of workers and sex allocation ratio, or between volume of nest and sex allocation ratio. In a laboratory experiment where ant colonies were kept in 470 and 860 mm 3 nests, larger colonies allocated more energy to produce sexual individuals. The results of this study show the selectivity of T. crassispinus ants regarding the size of nest cavity, and that the nest volume has an impact on life history parameters.

  20. Thermal conditions within tree cavities in ponderosa pine (Pinus ponderosa) forests: potential implications for cavity users

    Science.gov (United States)

    Vierling, Kerri T.; Lorenz, Teresa J.; Cunningham, Patrick; Potterf, Kelsi

    2017-11-01

    Tree cavities provide critical roosting and breeding sites for multiple species, and thermal environments in these cavities are important to understand. Our objectives were to (1) describe thermal characteristics in cavities between June 3 and August 9, 2014, and (2) investigate the environmental factors that influence cavity temperatures. We placed iButtons in 84 different cavities in ponderosa pine (Pinus ponderosa) forests in central Washington, and took hourly measurements for at least 8 days in each cavity. Temperatures above 40 °C are generally lethal to developing avian embryos, and 18% of the cavities had internal temperatures of ≥ 40 °C for at least 1 h of each day. We modeled daily maximum cavity temperature, the amplitude of daily cavity temperatures, and the difference between the mean internal cavity and mean ambient temperatures as a function of several environmental variables. These variables included canopy cover, tree diameter at cavity height, cavity volume, entrance area, the hardness of the cavity body, the hardness of the cavity sill (which is the wood below the cavity entrance which forms the barrier between the cavity and the external environment), and sill width. Ambient temperature had the largest effect size for maximum cavity temperature and amplitude. Larger trees with harder sills may provide more thermally stable cavity environments, and decayed sills were positively associated with maximum cavity temperatures. Summer temperatures are projected to increase in this region, and additional research is needed to determine how the thermal environments of cavities will influence species occupancy, breeding, and survival.

  1. Improved reactor cavity

    International Nuclear Information System (INIS)

    Katz, L.R.; Demarchais, W.E.

    1984-01-01

    A reactor pressure vessel disposed in a cavity has coolant inlet or outlet pipes extending through passages in the cavity walls and welded to pressure nozzles. The cavity wall has means for directing fluid away from a break at a weld away from the pressure vessel, and means for inhibiting flow of fluid toward the vessel. (author)

  2. Three-dimensional unsteady natural convection and entropy generation in an inclined cubical trapezoidal cavity with

    Directory of Open Access Journals (Sweden)

    Ahmed Kadhim Hussein

    2016-06-01

    Full Text Available Numerical computation of unsteady laminar three-dimensional natural convection and entropy generation in an inclined cubical trapezoidal air-filled cavity is performed for the first time in this work. The vertical right and left sidewalls of the cavity are maintained at constant cold temperatures. The lower wall is subjected to a constant hot temperature, while the upper one is considered insulated. Computations are performed for Rayleigh numbers varied as 103 ⩽ Ra ⩽ 105, while the trapezoidal cavity inclination angle is varied as 0° ⩽ Φ ⩽ 180°. Prandtl number is considered constant at Pr = 0.71. Second law of thermodynamics is applied to obtain thermodynamic losses inside the cavity due to both heat transfer and fluid friction irreversibilities. The variation of local and average Nusselt numbers is presented and discussed, while, streamlines, isotherms and entropy contours are presented in both two and three-dimensional pattern. The results show that when the Rayleigh number increases, the flow patterns are changed especially in three-dimensional results and the flow circulation increases. Also, the inclination angle effect on the total entropy generation becomes insignificant when the Rayleigh number is low. Moreover, when the Rayleigh number increases the average Nusselt number increases.

  3. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  4. Influence of dental filling material type on the concentration of interleukin 9 in the samples of gingival crevicular fluid

    Directory of Open Access Journals (Sweden)

    Stefanović Vladimir

    2016-01-01

    Full Text Available Background/Aim. Several cytokines and lymphokines (IL1β, ENA78, IL6, TNFα, IL8 and S100A8 are expressed during dental pulp inflammation. Analysis of gingival crevicu-lar fluid (GCF offers a non-invasive means of studying gen-eral host response in oral cavity. Although GCF levels of various mediators could reflect the state of inflammation both in dental pulp and gingiva adjacent to a tooth, GCF samples of those without significant gingivitis could be inter-preted as reflection of pulpal process. The aim of this study was to investigate IL9 GCF values in patients with dental car-ies and to assess possible influence of various dental fillings materials on local IL9 production. Methods. The study group included 90 patients, aged 18–70, with inclusion and exclusion criteria in the prospective clinical study. Of the 6 types of material used for the restoration of prepared cavities, 3 were intended for temporary and 3 for definitive restora-tion. According to dental fillings weight, all the participants were divided into 3 groups: those with fillings lighter than 0.50 g, those with 0.50–1.00 g, and those with fillings heavier than 1.00 g. Samples were taken from gingival sulcus using the filter paper technique. Clinical parameters were deter-mined by bleeding index, plaque index (Silness-Lou, 0–3, gingival index (0–3, and gingival sulcus depth. Cytokine con-centrations were assessed using commercially available cy-tomix. Results. According to the weight of dental fillings, there was a clear decreament trend of IL9 values meaning that dental defects greater than 1.00 g of dental filling were associated with lower GCF IL9 concentration. The IL9 val-ues correlated with the degree of gingival index and depth of gingival sulcus, being higher with more advanced gingivitis and more pronounced anatomical changes in the tooth edge. Different filling materials exerted various local IL9 responses. Zink polycarbonate cement and amalgam fillings induced

  5. Efficacy of XP-endo Finisher File in Removing Calcium Hydroxide from Simulated Internal Resorption Cavity.

    Science.gov (United States)

    Keskin, Cangül; Sariyilmaz, Evren; Sariyilmaz, Öznur

    2017-01-01

    The aim of this study was to evaluate the effect of supplementary use of XP-endo Finisher file, passive ultrasonic activation (PUI), EndoActivator (EA), and CanalBrush (CB) on the removal of calcium hydroxide (CH) paste from simulated internal resorption cavities. The root canals of 110 extracted single-rooted teeth with straight canals were prepared up to size 50. The specimens were split longitudinally, and standardized internal resorption cavities were prepared with burs. The cavities and root canals were filled with CH paste. The specimens were divided into 5 groups as follows: XP-endo Finisher, EA, PUI, CB, and syringe irrigation (SI). The root canals were irrigated with 5.25% NaOCl and 17% EDTA for 2 minutes, respectively. Apart from the SI group, both solutions were activated by using tested techniques for 1 minute. The quantity of CH remnants on resorption cavities was scored. Data were analyzed by using Kruskal-Wallis H and Mann-Whitney U tests. XP-endo Finisher and PUI removed significantly more CH than SI, EA, and CB (P  .05). Differences among SI, EA, and CB were also non-significant (P > .05). None of the tested techniques render the simulated internal resorption cavities free of CH debris. XP-endo Finisher and PUI were superior to SI, CB, and EA. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Comparative X-ray studies on the behaviour of amalgam and gold fillings at the margins in the approximal space as a function of time of residence

    International Nuclear Information System (INIS)

    Hansen, R.

    1982-01-01

    Within the framework of this thesis, X-ray pictures have been made of 430 gold or amalgam fillings in order to measure the gap between approximal cavity margin and filling margin. With amalgam fillings, the gap width measured after a residence time of half a year was 9.3 μm and widened to 136.9 μm after 8 years, which represents an increase to the 14-fold. The gap widths measured with gold inlays only doubled within this period, increasing from 38.8 μm after half a year to 77.4 μm after 8 years. The number of retention spots found in the approximal-cervical space with amalgam fillings was at least twice that found for gold fillings. From this it is concluded that gold inlays are by far the better solution for dental restorations. (orig./MG) [de

  7. Frequency-feedback cavity enhanced spectrometer

    Science.gov (United States)

    Hovde, David Christian; Gomez, Anthony

    2015-08-18

    A spectrometer comprising an optical cavity, a light source capable of producing light at one or more wavelengths transmitted by the cavity and with the light directed at the cavity, a detector and optics positioned to collect light transmitted by the cavity, feedback electronics causing oscillation of amplitude of the optical signal on the detector at a frequency that depends on cavity losses, and a sensor measuring the oscillation frequency to determine the cavity losses.

  8. Ethical and legal questions as regards filling out dental clinical charts

    Directory of Open Access Journals (Sweden)

    Mauro Henrique Nogueira Guimarãe de Abreu

    Full Text Available Objective: Evaluate imperfections in filling out dental clinical history charts of patients attended at the “Universidade Estadual de Montes Claros – Unimontes”, in 2005, from the ethical and legal aspects. Method: Descriptive statistical analysis, Pearson’s correlation, Chi-Square test (p<0.05 with Bonferroni correction in a contingency table (p<0.003 tests were performed, and Anova – Tukey (p<0.05 were calculate using SPSS software. This study was conducted using 881 clinical history charts of 19 subjects. Results: The highest percentage of charts concerned Stomatology (12% and 8 th period of the course (25%. The majority (63.3% of chartshad fields left blank and in 68% the handwriting was illegible. Unjustifiable erasures were found in 74.7% of charts. The majority of charts (98% were filled out in ink. The treatment plan was signed by course tutor in 83% of the cases. The term of consent was signed in the 94.9 % of the charts. As regards mistakes, 5.1% of documents had one error; 42% two errors; 23.5% three or more errors (average 1.89(± 0.9; percentile 25%=1; 50%=2 and 75%=2. The difference in the proportion of errors as regards filling out all fields differed statistically among the periods (p<0.05. Conclusion: It was concluded that an alarming number of documents were filled out incorrectly. The worst filling out performance was shown in the 5th, 6th and 7th periods (p<0.05.

  9. Setting of loose-fill insulation materials in walls; Saetningsfri indblaesning af loesfyldsisolering i vaegge

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, T.V.

    2001-07-01

    The report describes material behaviour, which significantly influences the settling of loose-fill insulation materials. The specific application presented here is loose-fill insulation material injected in walls as thermal insulation. The physical formulation of the issue to be discussed is that the mass is kept in position in the cavity by frictional forces, which counteracts the settling but complicates injection. The purpose of this study is to investigate whether there is a possibility that decreased friction will be able to release settling. Cellulose loose-fill material injected in a 0.1 m thick and 1 m wide gypsum wall with a minimum density of 48 kg/m3 was found not to settle if kept at a constant relative humidity, RH 50 %. A minimum density of 53 kg/m3 is necessary if the thickness of the wall is increased from 0.1 m to 0.3 m. If changing the constant environment from RH 50 % to RH 80 % a minimum density of 63 kg/m3 is necessary. Furthermore, results so far show that cellulose loose-fill material spread on the attic floor will have a density after settling of 48 kg /M3 for a constant RH 50 %, corresponding to 43 kg/m3 dry material. The results were found by using a model and tests. (au)

  10. The Effect of Resin-modified Glass-ionomer Cement Base and Bulk-fill Resin Composite on Cuspal Deformation.

    Science.gov (United States)

    Nguyen, K V; Wong, R H; Palamara, J; Burrow, M F

    2016-01-01

    This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base. Mesio-occluso-distal slot cavities of moderately large dimension were prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and restored with either a sonic-activated bulk-fill resin composite (RC) (SonicFill), or a conventional nanohybrid RC (Herculite Ultra). The base materials used were a flowable nanofilled RC (Premise Flowable) and a high-viscosity resin-modified glass-ionomer cement (RMGIC) (Riva Light-Cure HV). Cuspal deflection was measured with two direct current differential transformers, each contacting a buccal and palatal cusp. Cuspal movements were recorded during and after restoration placement. Data for the buccal and palatal cusp deflections were combined to give the net cuspal deflection. Data varied widely. All teeth experienced net inward cuspal movement. No statistically significant differences in cuspal deflection were found among the four test groups. The use of a flowable RC or an RMGIC in closed-laminate restorations produced the same degree of cuspal movement as restorations filled with only a conventional nanohybrid or bulk-fill RC.

  11. Ex vivo evaluation of coronal and apical microbial leakage of root canal - Filled with gutta-percha or Resilon/Epiphany root canal filling material

    Directory of Open Access Journals (Sweden)

    de Almeida-Gomes Fabio

    2010-01-01

    Full Text Available Objective: This ex vivo study compared coronal and apical microleakage of root canals filled with Resilon/Epiphany (RE or gutta-percha/Grossman sealer (GP, using either lateral condensation (LC or System B (SB technique. Materials and Methods: Specimens in eight experimental groups were obturated using the following materials and techniques: Groups 1 and 3 - GP and LC; groups 2 and 4 - GP and SB; groups 5 and 7 - RE and LC; groups 6 and 8 - RE and SB. Apical and coronal leakages were tested using bacterial methods. For coronal analysis, the number of days required for complete contamination of the root canals was recorded according to observation of the brain heart infusion broth turbidity for 15 weeks. For apical analysis, the teeth were cleaved and the leakage was measured at 30 days. Data were collected for each sample and analyzed statistically with the Chi-square and ANOVA tests. Results: Leakage was found in all groups. The difference between filling materials, obturation techniques, and median time of leakage was not statistically significant for coronal ( P=0.847 and apical ( P=0.5789 leakages. Conclusion: There were no differences between the different filling materials (gutta-percha/Grossman sealer and Resilon/Epiphany and obturation techniques (lateral condensation and system B technique in coronal or apical leakages.

  12. Experimental investigation of cavity flows

    Energy Technology Data Exchange (ETDEWEB)

    Loeland, Tore

    1998-12-31

    This thesis uses LDV (Laser Doppler Velocimetry), PIV (Particle Image Velocimetry) and Laser Sheet flow Visualisation to study flow inside three different cavity configurations. For sloping cavities, the vortex structure inside the cavities is found to depend upon the flow direction past the cavity. The shape of the downstream corner is a key factor in destroying the boundary layer flow entering the cavity. The experimental results agree well with numerical simulations of the same geometrical configurations. The results of the investigations are used to find the influence of the cavity flow on the accuracy of the ultrasonic flowmeter. A method to compensate for the cavity velocities is suggested. It is found that the relative deviation caused by the cavity velocities depend linearly on the pipe flow. It appears that the flow inside the cavities should not be neglected as done in the draft for the ISO technical report on ultrasonic flowmeters. 58 refs., 147 figs., 2 tabs.

  13. Experimental investigation of cavity flows

    Energy Technology Data Exchange (ETDEWEB)

    Loeland, Tore

    1999-12-31

    This thesis uses LDV (Laser Doppler Velocimetry), PIV (Particle Image Velocimetry) and Laser Sheet flow Visualisation to study flow inside three different cavity configurations. For sloping cavities, the vortex structure inside the cavities is found to depend upon the flow direction past the cavity. The shape of the downstream corner is a key factor in destroying the boundary layer flow entering the cavity. The experimental results agree well with numerical simulations of the same geometrical configurations. The results of the investigations are used to find the influence of the cavity flow on the accuracy of the ultrasonic flowmeter. A method to compensate for the cavity velocities is suggested. It is found that the relative deviation caused by the cavity velocities depend linearly on the pipe flow. It appears that the flow inside the cavities should not be neglected as done in the draft for the ISO technical report on ultrasonic flowmeters. 58 refs., 147 figs., 2 tabs.

  14. Early 500 MHz prototype LEP RF Cavity with superposed storage cavity

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    The principle of transferring the RF power back and forth between the accelerating cavity and a side-coupled storage cavity was demonstrated with this 500 MHz prototype. In LEP, the accelerating frequency was 352.2 MHz, and accelerating and storage cavities were consequently larger. See also 8002294, 8006061, 8407619X, and Annual Reports 1980, p.115; 1981, p.95; 1985, vol.I, p.13.

  15. NUMERICAL SIMULATIONS OF FLOW BEHAVIOR IN DRIVEN CAVITY AT HIGH REYNOLDS NUMBERS

    Directory of Open Access Journals (Sweden)

    Fudhail Bin Abdul Munir

    2012-02-01

    Full Text Available In recent years, due to rapidly increasing computational power, computational methods have become the essential tools to conduct researches in various engineering fields.  In parallel to the development of ultra high speed digital computers, computational fluid dynamics (CFD has become the new third approach apart from theory and experiment in the philosophical study and development of fluid dynamics.  Lattice Boltzmann method (LBM is an alternative method to conventional CFD.  LBM is relatively new approach that uses simple microscopic models to simulate complicated microscopic behavior of transport phenomena.  In this paper, fluid flow behaviors of steady incompressible flow inside lid driven square cavity are studied.  Numerical calculations are conducted for different Reynolds numbers by using Lattice Boltzmann scheme.  The objective of the paper is to demonstrate the capability of this lattice Boltzmann scheme for engineering applications particularly in fluid transport phenomena. Keywords-component; lattice Boltzmann method, lid driven cavity, computational fluid dynamics.

  16. Enhancement in heat transfer of a ferrofluid in a differentially heated square cavity through the use of permanent magnets

    Science.gov (United States)

    Joubert, J. C.; Sharifpur, M.; Solomon, A. Brusly; Meyer, J. P.

    2017-12-01

    The natural convection heat transfer of a magnetic nanofluid in a differentially heated cavity is investigated with and without an applied external magnetic field. The effects of volume fraction, magnetic field configuration, and magnetic field strength are investigated. Spherical Fe2O3 nanoparticles with a diameter of 15-20 nm are used in the nanofluids. Volume fractions ranging between 0.05% and 0.3% are tested for the case with no magnetic field, while only a volume fraction of 0.1% was tested in an externally applied magnetic field. The experiments were conducted for a range of Rayleigh numbers in 1.7 × 108 < Ra < 4.2 × 108. The viscosity of the nanofluid was determined experimentally. An empirical correlation for the viscosity was determined, and the stability of various nanofluids was investigated. Using heat transfer data obtained from the cavity, the average heat transfer coefficient and average Nusselt number for the nanofluids are determined. It was found that a volume fraction of 0.1% showed a maximum increase of 5.63% to the Nu at the maximum Ra. For the magnetic field study, it was found that the best-performing magnetic field enhanced the heat transfer behaviour by an additional 2.81% in Nu at Ra = 3.8 × 108.

  17. Final Technical Report on STTR Project DE-FG02-02ER86145 Pressurized RF Cavities for Muon Ionization Cooling

    International Nuclear Information System (INIS)

    Rolland Johnson

    2006-01-01

    This project was to design and build an RF test cell (TC), which could be operated at 800 MHz, filled with high pressure gases including hydrogen, at temperatures down to that of liquid nitrogen, in strong magnetic fields, in a strong radiation environment, and with interchangeable electrodes, in order to examine the use of high-pressure RF cavities for muon beam cooling

  18. Dosimetric properties of a novel brachytherapy balloon applicator for the treatment of malignant brain-tumor resection-cavity margins

    International Nuclear Information System (INIS)

    Dempsey, James F.; Williams, Jeffery A.; Stubbs, James B.; Patrick, Timothy J.; Williamson, Jeffrey F.

    1998-01-01

    Purpose: This paper characterizes the dosimetric properties of a novel balloon brachytherapy applicator for the treatment of the tissue surrounding the resection cavity of a malignant brain tumor. Methods and Materials: The applicator consists of an inflatable silicone balloon reservoir attached to a positionable catheter that is intraoperatively implanted into the resection cavity and postoperatively filled with a liquid radionuclide solution. A simple dosimetric model, valid in homogeneous media and based on results from Monte Carlo photon-transport simulations, was used to determine the dosimetric characteristics of spherical geometry balloons filled with photon-emitting radionuclide solutions. Fractional depth-dose (FDD) profiles, along with activity densities, and total activities needed to achieve specified dose rates were studied as a function of photon energy and source-containment geometry. Dose-volume histograms (DVHs) were calculated to compare idealized balloon-applicator treatments to conventional 125 I seed volume implants. Results: For achievable activity densities and total activities, classical low dose rate (LDR) treatments of residual disease at distances of up to 1 cm from the resection cavity wall are possible with balloon applicators having radii between 0.5 cm and 2.5 cm. The dose penetration of these applicators increases approximately linearly with balloon radius. The FDD profile can be made significantly more or less penetrating by combining selection of radionuclide with source-geometry manipulation. Comparisons with 125 I seed-implant DVHs show that the applicator can provide a more conformal therapy with no target tissue underdosing, less target tissue overdosing, and no healthy tissue ''hot spots;'' however, more healthy tissue volume receives a dose of the prescribed dosage or less. Conclusions: This device, when filled with 125 I solution, is suitable for classical LDR treatments and may be preferable to 125 I interstitial

  19. Crab cavities for linear colliders

    CERN Document Server

    Burt, G; Carter, R; Dexter, A; Tahir, I; Beard, C; Dykes, M; Goudket, P; Kalinin, A; Ma, L; McIntosh, P; Shulte, D; Jones, Roger M; Bellantoni, L; Chase, B; Church, M; Khabouline, T; Latina, A; Adolphsen, C; Li, Z; Seryi, Andrei; Xiao, L

    2008-01-01

    Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.

  20. SPS accelerating cavity

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The SPS started up with 2 accelerating cavities (each consisting of 5 tank sections) in LSS3. They have a 200 MHz travelling wave structure (see 7411032 and 7802190) and 750 kW of power is fed to each of the cavities from a 1 MW tetrode power amplifier, located in a surface building above, via a coaxial transmission line. Clemens Zettler, builder of the SPS RF system, is standing at the side of one of the cavities. In 1978 and 1979 another 2 cavities were added and entered service in 1980. These were part of the intensity improvement programme and served well for the new role of the SPS as proton-antiproton collider. See also 7411032, 8011289, 8104138, 8302397.

  1. Entropy Generation Analysis of Natural Convection in Square Enclosures with Two Isoflux Heat Sources

    Directory of Open Access Journals (Sweden)

    S. Z. Nejad

    2017-04-01

    Full Text Available This study investigates entropy generation resulting from natural convective heat transfer in square enclosures with local heating of the bottom and symmetrical cooling of the sidewalls. This analysis tends to optimize heat transfer of two pieces of semiconductor in a square electronic package. In this simulation, heaters are modeled as isoflux heat sources and sidewalls of the enclosure are isothermal heat sinks. The top wall and the non-heated portions of the bottom wall are adiabatic. Flow and temperature fields are obtained by numerical simulation of conservation equations of mass, momentum and energy in laminar, steady and two dimensional flows. With constant heat energy into the cavity, effect of Rayleigh number, heater length, heater strength ratios and heater position is evaluated on flow and temperature fields and local entropy generation. The results show that a minimum entropy generation rate is obtained under the same condition in which a minimum peak heater temperature is obtained.

  2. Transmucosal gas-loss rates in middle ears initially filled with O2 or CO2.

    Science.gov (United States)

    Kania, Romain E; Vérillaud, Benjamin; Ars, Bernard; Tran Ba Huy, Patrice; Herman, Philippe; Ar, Amos

    2016-10-01

    This study investigates the role of different gases in clearance of gas in the middle ear cavity (ME) by its mucosal blood flow. A rat model was used to measure gas volume changes in the ME cavity at constant pressure without ventilation. We disturbed the normal gas composition of the ME by filling it with O 2 or CO 2 , measured the consequent changes in gas volume over time and compared these results with previously obtained ones for air and N 2 . The first 5 min of the primary transient phase (phase I) for O 2 or CO 2 was characterized by a volume loss decrease of -0.49 ± 0.34 μL and -46.28 ± 8.49 μL, respectively, with volume loss increase for air and N 2 differing greatly, at +0.17 ± 0.17 and +2.31 ± 0.81, respectively. The CO 2 value of -46.28 μL showed that a volume of gas equivalent to that of the ME cleft volume was eliminated within the first 5 min. In the second phase (phase II), all gases showed a linear decrease in volume, which presumably represents a steady-state gas loss rate. However, the gas loss rate of -0.307 ± 0.170 μL min -1 for O 2 -filled MEs was significantly higher than the mean of -0.124 μL min -1 for all other gases. We used a previously established mathematical model to calculate the effective ME mucosal blood flow rate under steady-state (phase II) conditions. The blood flow results for O 2 -filled MEs differed greatly from those of the other gases (89.0 ± 49.28 vs. 26.5 μL min -1 , on average), which suggest that the model used to calculate blood flow should be modified if used with O 2 -filled MEs. Further work should involve a comparison of our method with different methods to verify ME blood flow rate. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Detection of Hazardous Cavities Below a Road Using Combined Geophysical Methods

    Science.gov (United States)

    De Giorgi, L.; Leucci, G.

    2014-07-01

    Assessment of the risk arising from near-surface natural hazard is a crucial step in safeguarding the security of the roads in karst areas. It helps authorities and other related parties to apply suitable procedures for ground treatment, mitigate potential natural hazards and minimize human and economic losses. Karstic terrains in the Salento Peninsula (Apulia region—South Italy) is a major challenge to engineering constructions and roads due to extensive occurrence of cavities and/or sinkholes that cause ground subsidence and both roads and building collapse. Cavities are air/sediment-filled underground voids, commonly developed in calcarenite sedimentary rocks by the infiltration of rainwater into the ground, opening up, over a long period of time, holes and tunnels. Mitigation of natural hazards can best be achieved through careful geoscientific studies. Traditionally, engineers use destructive probing techniques for the detection of cavities across regular grids or random distances. Such probing is insufficient on its own to provide confidence that cavities will not be encountered. Frequency of probing and depth of investigation may become more expensive. Besides, probing is intrusive, non-continuous, slow, expensive and cannot provide a complete lateral picture of the subsurface geology. Near-surface cavities usually can be easily detected by surface geophysical methods. Traditional and recently developed measuring techniques in seismic, geoelectrics and georadar are suitable for economical investigation of hazardous, potentially collapsing cavities. The presented research focused on an integrated geophysical survey that was carried out in a near-coast road located at Porto Cesareo, a small village a few kilometers south west of Lecce (south Italy). The roads in this area are intensively affected by dangerous surface cracks that cause structural instability. The survey aimed to image the shallow subsurface structures, including karstic features, and evaluate

  4. The LHC superconducting cavities

    CERN Document Server

    Boussard, Daniel; Häbel, E; Kindermann, H P; Losito, R; Marque, S; Rödel, V; Stirbet, M

    1999-01-01

    The LHC RF system, which must handle high intensity (0.5 A d.c.) beams, makes use of superconducting single-cell cavities, best suited to minimizing the effects of periodic transient beam loading. There will be eight cavities per beam, each capable of delivering 2 MV (5 MV/m accelerating field) at 400 MHz. The cavities themselves are now being manufactured by industry, using niobium-on-copper technology which gives full satisfaction at LEP. A cavity unit includes a helium tank (4.5 K operating temperature) built around a cavity cell, RF and HOM couplers and a mechanical tuner, all housed in a modular cryostat. Four-unit modules are ultimately foreseen for the LHC (two per beam), while at present a prototype version with two complete units is being extensively tested. In addition to a detailed description of the cavity and its ancillary equipment, the first test results of the prototype will be reported.

  5. Cavity-enhanced spectroscopies

    CERN Document Server

    van Zee, Roger

    2003-01-01

    ""Cavity-Enhanced Spectroscopy"" discusses the use of optical resonators and lasers to make sensitive spectroscopic measurements. This volume is written by the researcchers who pioneered these methods. The book reviews both the theory and practice behind these spectroscopic tools and discusses the scientific discoveries uncovered by these techniques. It begins with a chapter on the use of optical resonators for frequency stabilization of lasers, which is followed by in-depth chapters discussing cavity ring-down spectroscopy, frequency-modulated, cavity-enhanced spectroscopy, intracavity spectr

  6. Computational simulation of two-dimensional transient natural convection in volumetrically heated square enclosure

    International Nuclear Information System (INIS)

    Vieira, Camila Braga; Jian Su

    2010-01-01

    Natural convection is a physical phenomenon that has been investigated in nuclear engineering so as to provide information about heat transfer in severe accident conditions involving nuclear reactors. This research reported transient natural convection of fluids with uniformly distributed volumetrically heat generation in square cavity with isothermal side walls and adiabatic top/bottom walls. Two Prandtl numbers were considered, 0:0321 and 0:71. Direct numerical simulations were applied in order to obtain results about the velocities of the fluid in directions x and y. These results were used in Fast Fourier Transform, which showed the periodic, quasi-chaotic and chaotic behavior of transient laminar flow. (author)

  7. Hydroforming of elliptical cavities

    Science.gov (United States)

    Singer, W.; Singer, X.; Jelezov, I.; Kneisel, P.

    2015-02-01

    Activities of the past several years in developing the technique of forming seamless (weldless) cavity cells by hydroforming are summarized. An overview of the technique developed at DESY for the fabrication of single cells and multicells of the TESLA cavity shape is given and the major rf results are presented. The forming is performed by expanding a seamless tube with internal water pressure while simultaneously swaging it axially. Prior to the expansion the tube is necked at the iris area and at the ends. Tube radii and axial displacements are computer controlled during the forming process in accordance with results of finite element method simulations for necking and expansion using the experimentally obtained strain-stress relationship of tube material. In cooperation with industry different methods of niobium seamless tube production have been explored. The most appropriate and successful method is a combination of spinning or deep drawing with flow forming. Several single-cell niobium cavities of the 1.3 GHz TESLA shape were produced by hydroforming. They reached accelerating gradients Eacc up to 35 MV /m after buffered chemical polishing (BCP) and up to 42 MV /m after electropolishing (EP). More recent work concentrated on fabrication and testing of multicell and nine-cell cavities. Several seamless two- and three-cell units were explored. Accelerating gradients Eacc of 30 - 35 MV /m were measured after BCP and Eacc up to 40 MV /m were reached after EP. Nine-cell niobium cavities combining three three-cell units were completed at the company E. Zanon. These cavities reached accelerating gradients of Eacc=30 - 35 MV /m . One cavity is successfully integrated in an XFEL cryomodule and is used in the operation of the FLASH linear accelerator at DESY. Additionally the fabrication of bimetallic single-cell and multicell NbCu cavities by hydroforming was successfully developed. Several NbCu clad single-cell and double-cell cavities of the TESLA shape have been

  8. Cavity Processing and Preparation of 650 MHz Elliptical Cell Cavities for PIP-II

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Allan [Fermilab; Chandrasekaran, Saravan Kumar [Fermilab; Grassellino, Anna [Fermilab; Melnychuk, Oleksandr [Fermilab; Merio, Margherita [Fermilab; Reid, Thomas [Argonne (main); Sergatskov, Dmitri [Fermilab

    2017-05-01

    The PIP-II project at Fermilab requires fifteen 650 MHz SRF cryomodules as part of the 800 MeV LINAC that will provide a high intensity proton beam to the Fermilab neutrino program. A total of fifty-seven high-performance SRF cavities will populate the cryomodules and will operate in both pulsed and continuous wave modes. These cavities will be processed and prepared for performance testing utilizing adapted cavity processing infrastructure already in place at Fermilab and Argonne. The processing recipes implemented for these structures will incorporate state-of-the art processing and cleaning techniques developed for 1.3 GHz SRF cavities for the ILC, XFEL, and LCLS-II projects. This paper describes the details of the processing recipes and associated chemistry, heat treatment, and cleanroom processes at the Fermilab and Argonne cavity processing facilities. This paper also presents single and multi-cell cavity test results with quality factors above 5·10¹⁰ and accelerating gradients above 30 MV/m.

  9. Highly uniform residual layers for arrays of 3D nanoimprinted cavities in Fabry-Pérot-filter-array-based nanospectrometers

    Science.gov (United States)

    Memon, Imran; Shen, Yannan; Khan, Abdullah; Woidt, Carsten; Hillmer, Hartmut

    2016-04-01

    Miniaturized optical spectrometers can be implemented by an array of Fabry-Pérot (FP) filters. FP filters are composed of two highly reflecting parallel mirrors and a resonance cavity. Each filter transmits a small spectral band (filter line) depending on its individual cavity height. The optical nanospectrometer, a miniaturized FP-based spectrometer, implements 3D NanoImprint technology for the fabrication of multiple FP filter cavities in a single process step. However, it is challenging to avoid the dependency of residual layer (RL) thickness on the shape of the printed patterns in NanoImprint. Since in a nanospectrometer the filter cavities vary in height between neighboring FP filters and, thus, the volume of each cavity varies causing that the RL varies slightly or noticeably between different filters. This is one of the few disadvantages of NanoImprint using soft templates such as substrate conformal imprint lithography which is used in this paper. The advantages of large area soft templates can be revealed substantially if the problem of laterally inhomogeneous RLs can be avoided or reduced considerably. In the case of the nanospectrometer, non-uniform RLs lead to random variations in the designed cavity heights resulting in the shift of desired filter lines. To achieve highly uniform RLs, we report a volume-equalized template design with the lateral distribution of 64 different cavity heights into several units with each unit comprising four cavity heights. The average volume of each unit is kept constant to obtain uniform filling of imprint material per unit area. The imprint results, based on the volume-equalized template, demonstrate highly uniform RLs of 110 nm thickness.

  10. Measurement of the real time fill-pattern at the Australian Synchrotron

    International Nuclear Information System (INIS)

    Peake, D.J.; Boland, M.J.; LeBlanc, G.S.; Rassool, R.P.

    2008-01-01

    This article describes the development, commissioning and operation of a Fill-Pattern Monitor (FPM) for the Australian Synchrotron that measures the real-time intensity distribution of the electron bunches in the storage ring. Using a combination of an ultra-fast photodiode and a high-speed digitiser, real-time measurement of the fill-pattern at bunch-by-bunch resolution was achieved. The results compare very well with current methods of measuring the fill-pattern, such as a pick-up style detector. In addition, the FPM is fully integrated into the EPICS control system. The data provided by the FPM gives accurate RF bucket position and relative bunch currents over a wide range of stored beam currents, from 0.01 mA in a single bunch to 200 mA total beam current. The FPM monitors the success of an injection attempt into the storage ring and is used in a feedback loop to determine where to target the next injection. Using the FPM a beam top-up mode was successfully tested, resulting in a near constant beam current by periodic targeted injections over an 8 h shift. Results are presented for dynamically topped up real-time injection, where the beam pattern was squared using an intensity-dependent injection algorithm

  11. Formation of coronal cavities

    International Nuclear Information System (INIS)

    An, C.H.; Suess, S.T.; Tandberg-Hanssen, E.; Steinolfson, R.S.

    1986-01-01

    A theoretical study of the formation of a coronal cavity and its relation to a quiescent prominence is presented. It is argued that the formation of a cavity is initiated by the condensation of plasma which is trapped by the coronal magnetic field in a closed streamer and which then flows down to the chromosphere along the field lines due to lack of stable magnetic support against gravity. The existence of a coronal cavity depends on the coronal magnetic field strength; with low strength, the plasma density is not high enough for condensation to occur. Furthermore, we suggest that prominence and cavity material is supplied from the chromospheric level. Whether a coronal cavity and a prominence coexist depends on the magnetic field configuration; a prominence requires stable magnetic support

  12. The Superconducting TESLA Cavities

    CERN Document Server

    Aune, B.; Bloess, D.; Bonin, B.; Bosotti, A.; Champion, M.; Crawford, C.; Deppe, G.; Dwersteg, B.; Edwards, D.A.; Edwards, H.T.; Ferrario, M.; Fouaidy, M.; Gall, P-D.; Gamp, A.; Gössel, A.; Graber, J.; Hubert, D.; Hüning, M.; Juillard, M.; Junquera, T.; Kaiser, H.; Kreps, G.; Kuchnir, M.; Lange, R.; Leenen, M.; Liepe, M.; Lilje, L.; Matheisen, A.; Möller, W-D.; Mosnier, A.; Padamsee, H.; Pagani, C.; Pekeler, M.; Peters, H-B.; Peters, O.; Proch, D.; Rehlich, K.; Reschke, D.; Safa, H.; Schilcher, T.; Schmüser, P.; Sekutowicz, J.; Simrock, S.; Singer, W.; Tigner, M.; Trines, D.; Twarowski, K.; Weichert, G.; Weisend, J.; Wojtkiewicz, J.; Wolff, S.; Zapfe, K.

    2000-01-01

    The conceptional design of the proposed linear electron-positron colliderTESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with anaccelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. Thedesign goal for the cavities of the TESLA Test Facility (TTF) linac was set tothe more moderate value of Eacc >= 15 MV/m. In a first series of 27industrially produced TTF cavities the average gradient at Q0 = 5E+9 wasmeasured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering fromserious fabrication or material defects. In the second production of 24 TTFcavities additional quality control measures were introduced, in particular aneddy-current scan to eliminate niobium sheets with foreign material inclusionsand stringent prescriptions for carrying out the electron-beam welds. Theaverage gradient of these cavities at Q0 = 5E+9 amounts to 25.0 +- 3.2 MV/mwith the exception of one cavity suffering from a weld defect. Hence only amoderate improvement in production and preparation technique...

  13. Hydroforming of elliptical cavities

    Directory of Open Access Journals (Sweden)

    W. Singer

    2015-02-01

    Full Text Available Activities of the past several years in developing the technique of forming seamless (weldless cavity cells by hydroforming are summarized. An overview of the technique developed at DESY for the fabrication of single cells and multicells of the TESLA cavity shape is given and the major rf results are presented. The forming is performed by expanding a seamless tube with internal water pressure while simultaneously swaging it axially. Prior to the expansion the tube is necked at the iris area and at the ends. Tube radii and axial displacements are computer controlled during the forming process in accordance with results of finite element method simulations for necking and expansion using the experimentally obtained strain-stress relationship of tube material. In cooperation with industry different methods of niobium seamless tube production have been explored. The most appropriate and successful method is a combination of spinning or deep drawing with flow forming. Several single-cell niobium cavities of the 1.3 GHz TESLA shape were produced by hydroforming. They reached accelerating gradients E_{acc} up to 35  MV/m after buffered chemical polishing (BCP and up to 42  MV/m after electropolishing (EP. More recent work concentrated on fabrication and testing of multicell and nine-cell cavities. Several seamless two- and three-cell units were explored. Accelerating gradients E_{acc} of 30–35  MV/m were measured after BCP and E_{acc} up to 40  MV/m were reached after EP. Nine-cell niobium cavities combining three three-cell units were completed at the company E. Zanon. These cavities reached accelerating gradients of E_{acc}=30–35  MV/m. One cavity is successfully integrated in an XFEL cryomodule and is used in the operation of the FLASH linear accelerator at DESY. Additionally the fabrication of bimetallic single-cell and multicell NbCu cavities by hydroforming was successfully developed. Several NbCu clad single-cell and

  14. The mechanisms for filling carbon nanotubes with molten salts: carbon nanotubes as energy landscape filters

    International Nuclear Information System (INIS)

    Bishop, Clare L; Wilson, Mark

    2009-01-01

    The mechanisms for filling carbon nanotubes with molten salts are investigated using molecular dynamics computer simulation. Inorganic nanotubular structures, whose morphologies can be rationalized in terms of the folding, or the removal of sections from, planes of square nets are found to form. The formation mechanisms are found to follow a 'chain-by-chain' motif in which the structures build systematically from charge neutral M-X-M-Xc chains. The formation mechanisms are rationalized in terms of the ion-ion interactions (intra-chain and inter-chain terms). In addition, the mechanisms of filling are discussed in terms of a 'hopping' between basins on the underlying energy landscape. The role of the carbon nanotube as an energy landscape filter is discussed.

  15. Tuner Design for PEFP Superconducting RF Cavities

    International Nuclear Information System (INIS)

    Tang, Yazhe; An, Sun; Zhang, Liping; Cho, Yong Sub

    2009-01-01

    A superconducting radio frequency (SRF) cavity will be used to accelerate a proton beam after 100 MeV at 700 MHz in a linac of the Proton Engineering Frontier Project (PEFP) and its extended project. In order to control the SRF cavity's operating frequency at a low temperature, a new tuner has been developed for the PEFP SRF cavities. Each PEFP superconducting RF cavity has one tuner to match the cavity resonance frequency with the desired accelerator operating frequency; or to detune a cavity frequency a few bandwidths away from a resonance, so that the beam will not excite the fundamental mode, when the cavity is not being used for an acceleration. The PEFP cavity tuning is achieved by varying the total length of the cavity. The length of the cavity is controlled differentially by tuner acting with respect to the cavity body. The PEFP tuner is attached to the helium vessel and drives the cavity Field Probe (FP) side to change the frequency of the cavity

  16. Simulation at the SSCL low energy booster and coupled cavity linac

    International Nuclear Information System (INIS)

    Bourianoff, G.

    1991-01-01

    During the past year, the SSC has made significant use of the MFE computer center for simulating the low energy accelerators in the SSC complex. There are two primary supercomputer applications reported here. They are the calculation of emittance growth in the LEB due to space charge effects and simulation of the side coupled cavities used in the linac. The SSC is designed to have a luminosity of 10 33 interactions per second per square centimeter. It directly determines the amount of physics which can be done with the collider and is therefore of critical importance. The luminosity is inversely proportional to the emittance of the two colliding beams. Since emittance increases monotonically through the chain of accelerators, an emittance budget has been set up defining what the allowable emittance increase is in each individual component of the accelerator. The emittance budget for the LEB calls for the emittance to enter the LEB at .4π mm - mrad and leave the LEB at .6π mm -mrad. Therefore, a set of simulations was done to determine the actual emittance growth. The linac is designed to accelerate 25 MA of H - ions from 70 MEV to 600 MEV. There are several possible cavity designs which might be used but the side coupled cavity design operating in the π/2 mode has a number of advantages concerning operating stability and ease of manufacture. It has therefore been chosen for the linac accelerator

  17. LEP copper accelerating cavities

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    These copper cavities were used to generate the radio frequency electric field that was used to accelerate electrons and positrons around the 27-km Large Electron-Positron (LEP) collider at CERN, which ran from 1989 to 2000. The copper cavities were gradually replaced from 1996 with new superconducting cavities allowing the collision energy to rise from 90 GeV to 200 GeV by mid-1999.

  18. Geospatial data to support analysis of water-quality conditions in basin-fill aquifers in the southwestern United States

    Science.gov (United States)

    McKinney, Tim S.; Anning, David W.

    2009-01-01

    The Southwest Principal Aquifers study area consists of most of California and Nevada and parts of Utah, Arizona, New Mexico, and Colorado; it is about 409,000 square miles. The Basin-fill aquifers extend through about 201,000 square miles of the study area and are the primary source of water for cities and agricultural communities in basins in the arid and semiarid southwestern United States (Southwest). The demand on limited ground-water resources in areas in the southwestern United States has increased significantly. This increased demand underscores the importance of understanding factors that affect the water quality in basin-fill aquifers in the region, which are being studied through the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program. As a part of this study, spatial datasets of natural and anthropogenic factors that may affect ground-water quality of the basin-fill aquifers in the southwestern United States were developed. These data include physical characteristics of the region, such as geology, elevation, and precipitation, as well as anthropogenic factors, including population, land use, and water use. Spatial statistics for the alluvial basins in the Southwest have been calculated using the datasets. This information provides a foundation for the development of conceptual and statistical models that relate natural and anthropogenic factors to ground-water quality across the Southwest. A geographic information system (GIS) was used to determine and illustrate the spatial distribution of these basin-fill variables across the region. One hundred-meter resolution raster data layers that represent the spatial characteristics of the basins' boundaries, drainage areas, population densities, land use, and water use were developed for the entire Southwest.

  19. Effects of cavity-cavity interaction on the entanglement dynamics of a generalized double Jaynes-Cummings model

    Science.gov (United States)

    Pandit, Mahasweta; Das, Sreetama; Singha Roy, Sudipto; Shekhar Dhar, Himadri; Sen, Ujjwal

    2018-02-01

    We consider a generalized double Jaynes-Cummings model consisting of two isolated two-level atoms, each contained in a lossless cavity that interact with each other through a controlled photon-hopping mechanism. We analytically show that at low values of such a mediated cavity-cavity interaction, the temporal evolution of entanglement between the atoms, under the effects of cavity perturbation, exhibits the well-known phenomenon of entanglement sudden death (ESD). Interestingly, for moderately large interaction values, a complete preclusion of ESD is achieved, irrespective of its value in the initial atomic state. Our results provide a model to sustain entanglement between two atomic qubits, under the adverse effect of cavity induced perturbation, by introducing a non-intrusive inter-cavity photon exchange that can be physically realized through cavity-QED setups in contemporary experiments.

  20. Effects of low-intensity GaAlAs laser radiation (λ=660 nm) on dentine-pulp interface after class I cavity preparation

    International Nuclear Information System (INIS)

    Godoy, Bruno Miranda

    2003-01-01

    The aim of this study was to investigate the effects of low-intensity irradiation with GaAlAs laser (red emission) on the ultrastructure of dentine-pulp interface after conventionally prepared class I cavity preparation. Two patients with 8 premolars for extraction indicated for orthodontic reasons. Class I cavities were prepared in these teeth that were then divided into two groups. The first group received a treatment with laser with continuous emission, λ=660 nm, with maximum power output of 30 mW. The dosimetry applied was of approximately 2J/cm 2 , directly and perpendicularly into the cavity in only one section. After the irradiation, the cavities were filled with composite resin. The second group received the same treatment, except by the laser therapy. Twenty-eight days after the preparation, the teeth were extracted and were processed for transmission electron microscopy analysis. Two sound teeth, without any preparation, were also studied. The irradiated group presented odontoblastic processes in higher contact with the extracellular matrix and the collagen fibers appeared more aggregated and organized than those of control group. These results were also observed in the healthy-teeth. Thus, we suggest that laser irradiation accelerates the recovery of the dental structures involved in the cavity preparation at the pre-dentine level. (author)

  1. Lower hybrid wave cavities detected by the FREJA satellite

    International Nuclear Information System (INIS)

    Pecseli, H.L.; Iranpour, K.; Holter, Oe.; Lybekk, B.; Holtet J.; Truelsen, J.; Holback, B.

    1994-12-01

    Localized electrostatic wave packets in the frequency region of lower-hybrid waves have been detected by the instruments on the FREJA satellite. These waves are usually associated with local density depletions indicating that the structures can be interpreted as wave filled cavities. The basic features of the observations are discussed. Based on simple statistical arguments it is attempted to present some characteristics which have to be accommodated within an ultimate theory describing the observed wave phenomena. An explanation in terms of collapse of nonlinear lower-hybrid waves is discussed in particular. It is argued that such a model seems inapplicable, at least in its simplest form, by providing time and length scales which are not in agreement with observations. Alternatives to this model are presented. 24 refs., 8 figs

  2. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Science.gov (United States)

    2010-07-01

    ... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.72 Disposal of excess spoil: Valley fill/head-of-hollow fills.... Uncontrolled surface drainage may not be directed over the outslope of the fill. (2) Runoff from areas above the fill and runoff from the surface of the fill shall be diverted into stabilized diversion channels...

  3. Temperature Structure of a Coronal Cavity

    Science.gov (United States)

    Kucera, T. A.; Gibson, S. E.; Schmit, D. J.

    2011-01-01

    we analyze the temperature structure of a coronal cavity observed in Aug. 2007. coronal cavities are long, low-density structures located over filament neutral lines and are often seen as dark elliptical features at the solar limb in white light, EUV and x-rays. when these structures erupt they form the cavity portions of CMEs. It is important to establish the temperature structure of cavities in order to understand the thermodynamics of cavities in relation to their three-dimensional magnetic structure. To analyze the temperature we compare temperature ratios of a series of iron lines observed by the Hinode/EUv Imaging spectrometer (EIS). We also use those lines to constrain a forward model of the emission from the cavity and streamer. The model assumes a coronal streamer with a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel lenth. Temperature and density can be varied as a function of altitude both in the cavity and streamer. The general cavity morphology and the cavity and streamer density have already been modeled using data from STEREO's SECCHI/EUVI and Hinode/EIS (Gibson et al 2010 and Schmit & Gibson 2011).

  4. Normal Conducting RF Cavity for MICE

    International Nuclear Information System (INIS)

    Li, D.; DeMello, A.; Virostek, S.; Zisman, M.; Summers, D.

    2010-01-01

    Normal conducting RF cavities must be used for the cooling section of the international Muon Ionization Cooling Experiment (MICE), currently under construction at Rutherford Appleton Laboratory (RAL) in the UK. Eight 201-MHz cavities are needed for the MICE cooling section; fabrication of the first five cavities is complete. We report the cavity fabrication status including cavity design, fabrication techniques and preliminary low power RF measurements.

  5. Sodium fill of FFTF

    International Nuclear Information System (INIS)

    Waldo, J.B.; Greenwell, R.K.; Keasling, T.A.; Collins, J.R.; Klos, D.B.

    1980-02-01

    With construction of the Fast Flux Test Facility (FFTF) completed, the first major objective in the startup program was to fill the sodium systems. A sodium fill sequence was developed to match construction completion, and as systems became available, they were inerted, preheated, and filled with sodium. The secondary sodium systems were filled first while dry refueling system testing was in progress in the reactor vessel. The reactor vessel and the primary loops were filled last. This paper describes the methods used and some of the key results achieved for this major FFTF objective

  6. MRT-lattice Boltzmann computations of natural convection and volumetric radiation in a tilted square enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Moufekkir, F.; Moussaoui, M.A.; Mezrhab, A. [Laboratoire de Mecanique and Energetique, Faculte des sciences, Departement de physique 60000 Oujda (Morocco); Lemonnier, D. [Institut Pprime, CNRS-ENSMA-Univ. Poitiers, ENSMA, BP 40109, 86961 Futuroscope Chasseneuil cedex (France); Naji, H. [Universite Lille Nord de France, F-59000 Lille (France); Laboratoire Genie Civil and geo-Environnement - LGCgE- EA 4515, UArtois/FSA Bethune, F-62400 Bethune (France)

    2012-04-15

    A numerical analysis is carried out for natural convection while in an asymmetrically heated square cavity containing an absorbing emitting medium. The numerical approach adopted uses a hybrid thermal lattice Boltzmann method (HTLBM) in which the mass and momentum conservation equations are solved by using multiple relaxation time (MRT) model and the energy equation is solved separately by using the finite difference method (FDM). In addition, the radiative transfer equation (RTE) is treated by the discrete ordinates method (DOM) using the S8 quadrature to evaluate the source term of the energy equation. The effects of parameters such as the Rayleigh number Ra, the optical thickness {tau} and the inclination angle {phi}, are studied numerically to assess their impact on the flow and temperature distribution. The results presented in terms of isotherms, streamlines and averaged Nusselt number, show that in the absence of the radiation, the temperature and the flow fields are centro-symmetric and the cavity core is thermally stratified. However, radiation causes an overall increase in temperature and velocity gradients along both thermally active walls

  7. Weighted least-square approach for simultaneous measurement of multiple reflective surfaces

    Science.gov (United States)

    Tang, Shouhong; Bills, Richard E.; Freischlad, Klaus

    2007-09-01

    Phase shifting interferometry (PSI) is a highly accurate method for measuring the nanometer-scale relative surface height of a semi-reflective test surface. PSI is effectively used in conjunction with Fizeau interferometers for optical testing, hard disk inspection, and semiconductor wafer flatness. However, commonly-used PSI algorithms are unable to produce an accurate phase measurement if more than one reflective surface is present in the Fizeau interferometer test cavity. Examples of test parts that fall into this category include lithography mask blanks and their protective pellicles, and plane parallel optical beam splitters. The plane parallel surfaces of these parts generate multiple interferograms that are superimposed in the recording plane of the Fizeau interferometer. When using wavelength shifting in PSI the phase shifting speed of each interferogram is proportional to the optical path difference (OPD) between the two reflective surfaces. The proposed method is able to differentiate each underlying interferogram from each other in an optimal manner. In this paper, we present a method for simultaneously measuring the multiple test surfaces of all underlying interferograms from these superimposed interferograms through the use of a weighted least-square fitting technique. The theoretical analysis of weighted least-square technique and the measurement results will be described in this paper.

  8. Molar cusp deformation evaluated by micro-CT and enamel crack formation to compare incremental and bulk-filling techniques.

    Science.gov (United States)

    Oliveira, Laís Rani Sales; Braga, Stella Sueli Lourenço; Bicalho, Aline Arêdes; Ribeiro, Maria Tereza Hordones; Price, Richard Bengt; Soares, Carlos José

    2018-07-01

    To describe a method of measuring the molar cusp deformation using micro-computed tomography (micro-CT), the propagation of enamel cracks using transillumination, and the effects of hygroscopic expansion after incremental and bulk-filling resin composite restorations. Twenty human molars received standardized Class II mesio-occlusal-distal cavity preparations. They were restored with either a bulk-fill resin composite, X-tra fil (XTRA), or a conventional resin composite, Filtek Z100 (Z100). The resin composites were tested for post-gel shrinkage using a strain gauge method. Cusp deformation (CD) was evaluated using the images obtained using a micro-CT protocol and using a strain-gauge method. Enamel cracks were detected using transillumination. The post-gel shrinkage of Z100 was higher than XTRA (P cracks than XTRA (P = 0.012). Micro-CT was an effective method for evaluating the cusp deformation. Transillumination was effective for detecting enamel cracks. There were fewer negative effects of polymerization shrinkage in bulk-fill resin restorations using XTRA than for the conventional incremental filling technique using conventional composite resin Z100. Shrinkage and cusp deformation are directly related to the formation of enamel cracks. Cusp deformation and crack propagation may increase the risk of tooth fracture. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Hollow waveguide cavity ringdown spectroscopy

    Science.gov (United States)

    Dreyer, Chris (Inventor); Mungas, Greg S. (Inventor)

    2012-01-01

    Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

  10. NUMERICAL SIMULATION OF METAL MELT FLOWS IN MOLD CAVITY WITH CERAMIC POROUS MEDIA

    Directory of Open Access Journals (Sweden)

    Changchun Dong

    2016-05-01

    Full Text Available Process modeling of metal melt flow in porous media plays an important role in casting of metal matrix composites. In this work, a mathematical model of the metal melt flow in preform ceramic particles was used to simulate the flow behavior in a mold cavity. The effects of fluid viscosity and permeability (mainly affected by porosity of ceramic preforms on the flow behavior were analyzed. The results indicate that ceramic porous media have a significant effect on the flow behavior by contributing to a low filling velocity and sharp pressure drop in the cavity. The pressure drop has a linear relationship with the fluid velocity, and a nonlinear relationship with porosity. When the porosity is relatively small, the pressure drop is extremely large. When porosity exceeds a certain value, the pressure drop is independent of porosity. The relationship between viscosity and porosity is described, and it is shown that the critical porosity changes when the viscosity of the melt changes. However, due to the limited viscosity change, the critical porosity changes by less than 0.043.

  11. Polymerization stress evolution of a bulk-fill flowable composite under different compliances.

    Science.gov (United States)

    Guo, Yongwen; Landis, Forrest A; Wang, Zhengzhi; Bai, Ding; Jiang, Li; Chiang, Martin Y M

    2016-04-01

    To use a compliance-variable instrument to simultaneously measure and compare the polymerization stress (PS) evolution, degree of conversion (DC), and exotherm of a bulk-fill flowable composite to a packable composite. A bulk-fill flowable composite (Filtek Bulk-fill, FBF) and a conventional packable composite (Filtek Z250, Z250) purchased from 3M ESPE were investigated. The composites were studied using a cantilever-beam based instrument equipped with an in situ near infrared (NIR) spectrometer and a microprobe thermocouple. The measurements were carried out under various instrumental compliances (ranging from 0.3327μm/N to 12.3215μm/N) that are comparable to the compliances of clinically prepared tooth cavities. Correlations between the PS and temperature change as well as the DC were interpreted. The maximum PS of both composites at 10min after irradiation decreased with the increase in the compliance of the cantilever beam. The FBF composite generated a lower final stress than the Z250 sample under instrumental compliances less than ca. 4μm/N; however, both materials generated statistically similar PS values at higher compliances. The reaction exotherm and the DC of both materials were found to be independent of compliance. The DC of the FBF sample was slightly higher than that of the packable Z250 composite while the peak exotherm of FBF was almost double that of the Z250 composite. For FBF, a characteristic drop in the PS was observed during the early stage of polymerization for all compliances studied which was not observed in the Z250 sample. This drop was shown to relate to the greater exotherm of the less-filled FBF sample relative to the Z250 composite. While the composites with lower filler content (low viscosity) are generally considered to have lower PS than the conventional packable composites, a bulk-fill flowable composite was shown to produce lower PS under a lower compliance of constraint as would be experienced if the composite was used as

  12. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  13. Stem cell niche-specific Ebf3 maintains the bone marrow cavity.

    Science.gov (United States)

    Seike, Masanari; Omatsu, Yoshiki; Watanabe, Hitomi; Kondoh, Gen; Nagasawa, Takashi

    2018-03-01

    Bone marrow is the tissue filling the space between bone surfaces. Hematopoietic stem cells (HSCs) are maintained by special microenvironments known as niches within bone marrow cavities. Mesenchymal cells, termed CXC chemokine ligand 12 (CXCL12)-abundant reticular (CAR) cells or leptin receptor-positive (LepR + ) cells, are a major cellular component of HSC niches that gives rise to osteoblasts in bone marrow. However, it remains unclear how osteogenesis is prevented in most CAR/LepR + cells to maintain HSC niches and marrow cavities. Here, using lineage tracing, we found that the transcription factor early B-cell factor 3 (Ebf3) is preferentially expressed in CAR/LepR + cells and that Ebf3-expressing cells are self-renewing mesenchymal stem cells in adult marrow. When Ebf3 is deleted in CAR/LepR + cells, HSC niche function is severely impaired, and bone marrow is osteosclerotic with increased bone in aged mice. In mice lacking Ebf1 and Ebf3 , CAR/LepR + cells exhibiting a normal morphology are abundantly present, but their niche function is markedly impaired with depleted HSCs in infant marrow. Subsequently, the mutants become progressively more osteosclerotic, leading to the complete occlusion of marrow cavities in early adulthood. CAR/LepR + cells differentiate into bone-producing cells with reduced HSC niche factor expression in the absence of Ebf1/Ebf3 Thus, HSC cellular niches express Ebf3 that is required to create HSC niches, to inhibit their osteoblast differentiation, and to maintain spaces for HSCs. © 2018 Seike et al.; Published by Cold Spring Harbor Laboratory Press.

  14. Identification and characterization of near surface cavities in Tuwaiq Mountain Limestone, Riyadh, KSA, “detection and treatment”

    Directory of Open Access Journals (Sweden)

    Ahmed Abd El Aal

    2017-03-01

    Full Text Available This study evaluates the capability of surface electrical resistivity technique for identifying the weak zones or subsurface cavities in karst area with limestone rocks. Weak zones or cavities near surface can be potentially dangerous and several problems are associated with collapse of roads or buildings accompanied by subsidence phenomena. Karst environments are characterized by distinctive landforms, which are related to dissolution and dominant subsurface drainage. The interaction of limestone with water is able to create karst features such as cavity, pinnacle, boulder and sinkhole through the dissolution process. The existence of subsurface karst features are always a matter of concern to engineers before any development starts because these features could cause disaster in the future. The study was conducted at Tuwaiq Mountain Limestone, Riyadh region, KSA with the objective to detect and treat karst features at limestone rocks. The karst features such as fill cavity, boulder, pinnacle, discontinuity and overhang were detected in the survey lines. The 2-D ER results showed a good correlation with all the borehole records in determining the subsurface of limestone formation. The 2-D ER method is capable in mapping karst features and bedrock depth. The ability of the electrical technique to produce high resolution images of the subsurface, which are useful for subsidence assessment is illustrated.

  15. Fetal frontal cortex transplant (14C) 2-deoxyglucose uptake and histology: survival in cavities of host rat brain motor cortex

    International Nuclear Information System (INIS)

    Sharp, F.R.; Gonzalez, M.F.

    1984-01-01

    Fetal frontal neocortex from 18-day-old rat embryonic brain was transplanted into cavities in 30-day-old host motor cortex. Sixty days after transplantation, 5 of 15 transplanted rats had surviving fetal transplants. The fetal cortex transplants were physically attached to the host brain, completely filled the original cavity, and had numerous surviving cells including pyramidal neurons. Cell lamination within the fetal transplant was abnormal. The ( 14 C) 2-deoxyglucose uptake of all five of the fetal neocortex transplants was less than adjacent cortex and contralateral host motor-sensory cortex, but more than adjacent corpus callosum white matter. The results indicate that fetal frontal neocortex can be transplanted into damaged rat motor cortex. The metabolic rate of the transplants suggests they could be partially functional

  16. Digital squares

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Kim, Chul E

    1988-01-01

    Digital squares are defined and their geometric properties characterized. A linear time algorithm is presented that considers a convex digital region and determines whether or not it is a digital square. The algorithm also determines the range of the values of the parameter set of its preimages....... The analysis involves transforming the boundary of a digital region into parameter space of slope and y-intercept...

  17. About Dental Amalgam Fillings

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...

  18. Optimization and Prediction of Angular Distortion and Weldment Characteristics of TIG Square Butt Joints

    Science.gov (United States)

    Narang, H. K.; Mahapatra, M. M.; Jha, P. K.; Biswas, P.

    2014-05-01

    Autogenous arc welds with minimum upper weld bead depression and lower weld bead bulging are desired as such welds do not require a second welding pass for filling up the upper bead depressions (UBDs) and characterized with minimum angular distortion. The present paper describes optimization and prediction of angular distortion and weldment characteristics such as upper weld bead depression and lower weld bead bulging of TIG-welded structural steel square butt joints. Full factorial design of experiment was utilized for selecting the combinations of welding process parameter to produce the square butts. A mathematical model was developed to establish the relationship between TIG welding process parameters and responses such as upper bead width, lower bead width, UBD, lower bead height (bulging), weld cross-sectional area, and angular distortions. The optimal welding condition to minimize UBD and lower bead bulging of the TIG butt joints was identified.

  19. A SURVEY OF CORONAL CAVITY DENSITY PROFILES

    International Nuclear Information System (INIS)

    Fuller, J.; Gibson, S. E.

    2009-01-01

    Coronal cavities are common features of the solar corona that appear as darkened regions at the base of coronal helmet streamers in coronagraph images. Their darkened appearance indicates that they are regions of lowered density embedded within the comparatively higher density helmet streamer. Despite interfering projection effects of the surrounding helmet streamer (which we refer to as the cavity rim), Fuller et al. have shown that under certain conditions it is possible to use a Van de Hulst inversion of white-light polarized brightness (pB) data to calculate the electron density of both the cavity and cavity rim plasma. In this article, we apply minor modifications to the methods of Fuller et al. in order to improve the accuracy and versatility of the inversion process, and use the new methods to calculate density profiles for both the cavity and cavity rim in 24 cavity systems. We also examine trends in cavity morphology and how departures from the model geometry affect our density calculations. The density calculations reveal that in all 24 cases the cavity plasma has a flatter density profile than the plasma of the cavity rim, meaning that the cavity has a larger density depletion at low altitudes than it does at high altitudes. We find that the mean cavity density is over four times greater than that of a coronal hole at an altitude of 1.2 R sun and that every cavity in the sample is over twice as dense as a coronal hole at this altitude. Furthermore, we find that different cavity systems near solar maximum span a greater range in density at 1.2 R sun than do cavity systems near solar minimum, with a slight trend toward higher densities for systems nearer to solar maximum. Finally, we found no significant correlation of cavity density properties with cavity height-indeed, cavities show remarkably similar density depletions-except for the two smallest cavities that show significantly greater depletion.

  20. Design of a compact high-speed optical modulator based on a hybrid plasmonic nanobeam cavity

    Science.gov (United States)

    Javid, Mohammad Reza; Miri, Mehdi; Zarifkar, Abbas

    2018-03-01

    A hybrid plasmonic electro-optic modulator based on a polymer-filled one dimensional photonic crystal nanobeam (1D PhCNB) cavity is proposed here. In the proposed structure the optical intensity modulation is realized by shifting the resonant wavelength of the cavity through electrically tuning the refractive index of the electro-optic polymer in the hybrid plasmonic waveguide. As a result of the subwavelength light confinement in the hybrid plasmonic waveguide and the compact footprint of the 1D PhCNB cavity, the designed modulator has the small overall footprint of 3 . 6 μm2 and the required wavelength shift can be achieved by applying very small actuating power. Three dimensional finite-difference time-domain (3D-FDTD) simulations show that the modulation depth of 10.9 dB, and insertion loss of 1.14 dB, along with very high modulation speed of 224 GHz can be achieved in the proposed modulator with very low modulation energy of 0.75 fJ/bit. A comparison between the performance parameters of the proposed modulator and those of previously reported PhCNB based modulators reveals the superior performance of the proposed structure in terms of modulation speed, energy consumption and overall footprint.

  1. radiofrequency cavity

    CERN Multimedia

    1988-01-01

    The pulse of a particle accelerator. 128 of these radio frequency cavities were positioned around CERN's 27-kilometre LEP ring to accelerate electrons and positrons. The acceleration was produced by microwave electric oscillations at 352 MHz. The electrons and positrons were grouped into bunches, like beads on a string, and the copper sphere at the top stored the microwave energy between the passage of individual bunches. This made for valuable energy savings as it reduced the heat generated in the cavity.

  2. Earth-ionosphere cavity

    International Nuclear Information System (INIS)

    Tran, A.; Polk, C.

    1976-01-01

    To analyze ELF wave propagation in the earth-ionosphere cavity, a flat earth approximation may be derived from the exact equations, which are applicable to the spherical cavity, by introducing a second-order or Debye approximation for the spherical Hankel functions. In the frequency range 3 to 30 Hz, however, the assumed conditions for the Debye approximation are not satisfied. For this reason an exact evaluation of the spherical Hankel functions is used to study the effects of the flat earth approximation on various propagation and resonance parameters. By comparing the resonance equation for a spherical cavity with its flat earth counterpart and by assuming that the surface impedance Z/sub i/ at the upper cavity boundary is known, the relation between the eigenvalue ν and S/sub v/, the sine of the complex angle of incidence at the lower ionosphere boundary, is established as ν(ν + 1) = (kaS/sub v/) 2 . It is also shown that the approximation ν(ν + 1) approximately equals (ν + 1/2) 2 which was used by some authors is not adequate below 30 Hz. Numerical results for both spherical and planar stratification show that (1) planar stratification is adequate for the computation of the lowest three ELF resonance frequencies to within 0.1 Hz; (2) planar stratification will lead to errors in cavity Q and wave attenuation which increase with frequency; (3) computation of resonance frequencies to within 0.1 Hz requires the extension of the lower boundary of the ionosphere to a height where the ratio of conduction current to displacement current, (sigma/ωepsilon 0 ), is less than 0.3; (4) atmospheric conductivity should be considered down to ground level in computing cavity Q and wave attenuation

  3. Cavity design programs

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1996-01-01

    Numerous computer programs are available to help accelerator physicists and engineers model and design accelerator cavities and other microwave components. This article discusses the problems these programs solve and the principles upon which these programs are based. Some examples of how these programs are used in the design of accelerator cavities are also given

  4. Partial Cavity Flows at High Reynolds Numbers

    Science.gov (United States)

    Makiharju, Simo; Elbing, Brian; Wiggins, Andrew; Dowling, David; Perlin, Marc; Ceccio, Steven

    2009-11-01

    Partial cavity flows created for friction drag reduction were examined on a large-scale. Partial cavities were investigated at Reynolds numbers up to 120 million, and stable cavities with frictional drag reduction of more than 95% were attained at optimal conditions. The model used was a 3 m wide and 12 m long flat plate with a plenum on the bottom. To create the partial cavity, air was injected at the base of an 18 cm backwards-facing step 2.1 m from the leading edge. The geometry at the cavity closure was varied for different flow speeds to optimize the closure of the cavity. Cavity gas flux, thickness, frictional loads, and cavity pressures were measured over a range of flow speeds and air injection fluxes. High-speed video was used extensively to investigate the unsteady three dimensional cavity closure, the overall cavity shape and oscillations.

  5. TEM observations of crack tip: cavity interactions

    International Nuclear Information System (INIS)

    Horton, J.A.; Ohr, S.M.; Jesser, W.A.

    1981-01-01

    Crack tip-cavity interactions have been studied by performing room temperature deformation experiments in a transmission electron microscope on ion-irradiated type 316 stainless steel with small helium containing cavities. Slip dislocations emitted from a crack tip cut, sheared, and thereby elongated cavities without a volume enlargement. As the crack tip approached, a cavity volume enlargement occurred. Instead of the cavities continuing to enlarge until they touch, the walls between the cavities fractured. Fracture surface dimples do not correlate in size or density with these enlarged cavities

  6. Accumulation and conversion of sugars by developing wheat grains. VII. Effect of changes in sieve tube and endosperm cavity sap concentrations on the grain filling rate

    International Nuclear Information System (INIS)

    Fisher, D.B.; Gifford, R.M.

    1987-01-01

    The extent to which wheat grain growth is dependent on transport pool solute concentration was investigated by the use of illumination and partial grain removal to vary solute concentrations in the sieve tube and endosperm cavity saps of the wheat ear (Triticum aestivum L.). Short-term grain growth rates were estimated indirectly from the product of phloem area, sieve tube sap concentration, and 32 P translocation velocity. On a per grain basis, calculated rates of mass transport through the peduncle were fairly constant over a substantial range in other transport parameters (i.e. velocity, concentration, phloem area, and grain number). The rates were about 40% higher than expected; this probably reflects some unavoidable bias on faster-moving tracer in the velocity estimates. Sieve tube sap concentration increased in all experiments (by 20 to 64%), with a concomitant decline in velocity (to as low as 8% of the initial value). Endosperm cavity sucrose concentration also increased in all experiments, but cavity sap osmolality and total amino acid concentration remained nearly constant. No evidence was found for an increase in the rate of mass transport per grain through the peduncle in response to the treatments. This apparent unresponsiveness of grain growth rate to increased cavity sap sucrose concentration conflicts with earlier in vitro endosperm studies showing that sucrose uptake increased with increasing external sucrose concentration up to 150 to 200 millimolar

  7. STRUCTURAL ANALYSIS OF SUPERCONDUCTING ACCELERATOR CAVITIES

    International Nuclear Information System (INIS)

    Schrage, D.

    2000-01-01

    The static and dynamic structural behavior of superconducting cavities for various projects was determined by finite element structural analysis. The β = 0.61 cavity shape for the Neutron Science Project was studied in detail and found to meet all design requirements if fabricated from five millimeter thick material with a single annular stiffener. This 600 MHz cavity will have a Lorentz coefficient of minus1.8 Hz/(Mv/meter) 2 and a lowest structural resonance of more than 100 Hz. Cavities at β = 0.48, 0.61, and 0.77 were analyzed for a Neutron Science Project concept which would incorporate 7-cell cavities. The medium and high beta cavities were found to meet all criteria but it was not possible to generate a β = 0.48 cavity with a Lorentz coefficient of less than minus3 Hz/(Mv/meter) 2

  8. The effect of gingival wall location on the marginal seal of class ii restorations prepared with a flowable bulk-fill resin-based composite.

    Science.gov (United States)

    Segal, P; Candotto, V; Ben-Amar, A; Eger, M; Matalon, S; Lauritano, D; Ormianer, Z

    2018-01-01

    SureFil SDR is a flowable resin-based composite that allows a single incremental bulk placement. The marginal seal of SureFil SDR at the gingival margins of class II restorations located apical to the cemento-enamel-junction (CEJ) has not been adequately evaluated compared to those located occlusal to the CEJ. Forty class II cavities were prepared in human molars. The gingival margins of 20 preparations were located 0.5 mm occlusal to the CEJ, and the other 20 preparations were located 0.5 mm apical to the CEJ. The cavities surfaces were bonded with XenoV dental adhesive and filled with SDR in one bulk increment up to 4 mm, after which they were covered with CeramX. The teeth were subjected to thermo-and load-cycling, and their gingival margins were exposed to 0.5% basic-fuchsin solution. The specimens were sectioned mesio-distally and scored for microleakage. A Wilcoxon test for pairwise comparison was performed to determine significance. Dye penetration was observed in 30% of the 20 restorations with cavo-surface margins located occlusal to the CEJ and in 55% of the 20 restorations with cavo-surface margins located apical to the CEJ. The bulk-fill flowable resin base SureFil SDR with XenoV dental adhesive provided a better marginal seal in class II restorations with gingival margins above the CEJ compared to restorations with gingival margins below the CEJ. SDR should not be recommended for class II cavity preparations with gingival margins located below the CEJ.

  9. Superconducting cavities developments efforts at RRCAT

    International Nuclear Information System (INIS)

    Puntambekar, A.; Bagre, M.; Dwivedi, J.; Shrivastava, P.; Mundra, G.; Joshi, S.C.; Potukuchi, P.N.

    2011-01-01

    Superconducting RE cavities are the work-horse for many existing and proposed linear accelerators. Raja Ramanna Centre for Advanced Technology (RRCAT) has initiated a comprehensive R and D program for development of Superconducting RF cavities suitable for high energy accelerator application like SNS and ADS. For the initial phase of technology demonstration several prototype 1.3 GHz single cell-cavities have been developed. The work began with development of prototype single cell cavities in aluminum and copper. This helped in development of cavity manufacturing process, proving various tooling and learning on various mechanical and RF qualification processes. The parts manufacturing was done at RRCAT and Electron beam welding was carried out at Indian industry. These cavities further served during commissioning trials for various cavity processing infrastructure being developed at RRCAT and are also a potential candidate for Niobium thin film deposition R and D. Based on the above experience, few single cell cavities were developed in fine grain niobium. The critical technology of forming and machining of niobium and the intermediate RF qualification were developed at RRCAT. The EB welding of bulk niobium cavities was carried out in collaboration with IUAC, New Delhi at their facility. As a next logical step efforts are now on for development of multicell cavities. The prototype dumbbells and end group made of aluminium, comprising of RF and HOM couplers ports have also been developed, with their LB welding done at Indian industry. In this paper we shall present the development efforts towards manufacturing of 1.3 GHz single cell cavities and their initial processing and qualification. (author)

  10. Effect of cavity disinfectants on antibacterial activity and microtensile bond strength in class I cavity.

    Science.gov (United States)

    Kim, Bo-Ram; Oh, Man-Hwan; Shin, Dong-Hoon

    2017-05-31

    This study was performed to compare the antibacterial activities of three cavity disinfectants [chlorhexidine (CHX), NaOCl, urushiol] and to evaluate their effect on the microtensile bond strength of Scotchbond Universal Adhesive (3M-ESPE, St. Paul, MN, USA) in class I cavities. In both experiments, class I cavities were prepared in dentin. After inoculation with Streptococcus mutans, the cavities of control group were rinsed and those of CHX, NaOCl and urushiol groups were treated with each disinfectant. Standardized amounts of dentin chips were collected and number of S. mutans was determined. Following the same cavity treatment, same adhesive was applied in etch-and-rinse mode. Then, microtensile bond strength was evaluated. The number of S. mutans was significantly reduced in the cavities treated with CHX, NaOCl, and urushiol compared with control group (p<0.05). However, there was a significant bond strength reduction in NaOCl group, which showed statistical difference compared to the other groups (p<0.05).

  11. 21 CFR 872.3260 - Cavity varnish.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cavity varnish. 872.3260 Section 872.3260 Food and... DENTAL DEVICES Prosthetic Devices § 872.3260 Cavity varnish. (a) Identification. Cavity varnish is a device that consists of a compound intended to coat a prepared cavity of a tooth before insertion of...

  12. Geometric Model of a Coronal Cavity

    Science.gov (United States)

    Kucera, Therese A.; Gibson, S. E.; Ratawicki, D.; Dove, J.; deToma, G.; Hao, J.; Hudson, H. S.; Marque, C.; McIntosh, P. S.; Reeves, K. K.; hide

    2010-01-01

    We observed a coronal cavity from August 8-18 2007 during a multi-instrument observing campaign organized under the auspices of the International Heliophysical Year (IHY). Here we present initial efforts to model the cavity with a geometrical streamer-cavity model. The model is based the white-light streamer mode] of Gibson et a]. (2003 ), which has been enhanced by the addition of a cavity and the capability to model EUV and X-ray emission. The cavity is modeled with an elliptical cross-section and Gaussian fall-off in length and width inside the streamer. Density and temperature can be varied in the streamer and cavity and constrained via comparison with data. Although this model is purely morphological, it allows for three-dimensional, multi-temperature analysis and characterization of the data, which can then provide constraints for future physical modeling. Initial comparisons to STEREO/EUVI images of the cavity and streamer show that the model can provide a good fit to the data. This work is part of the effort of the International Space Science Institute International Team on Prominence Cavities

  13. Microleakage of conventional, resin-modified, and nano-ionomer glass ionomer cement as primary teeth filling material

    Directory of Open Access Journals (Sweden)

    Dita Madyarani

    2014-12-01

    Full Text Available Background: Glass ionomer cements are one of many dental materials that widely used in pediatric dentistry due to their advantage of fluoride release and chemical bond to tooth structure. Adherence of the filling material to the cavity walls is one of the most important characteristic that need to be examined its effect on microleakage. Purpose: This study was conducted to examine the microleakage of nano-ionomer glass ionomer cement compared with the conventional and resin-modified glass ionomer cements. Methods: Standard class V cavities sized 3 mm x 2 mm x 2 mm were made on a total of 21 extracted maxillary primary canine teeth and restored with the conventional, resin-modified, dan nano-ionomer glass ionomer cements. All the teeth were immersed in a 2% methylene blue dye for 4 hours. The depth of dye penetration was assessed using digital microscope after sectioning the teeth labio-palatally. The results were statistically analyzed using Kruskal-Wallis test. Results: All type of glass ionomer material showed microleakage. Conventional glass ionomer cement demonstrated the least microleakage with mean score 1.29. the resin-modified glass ionomer cements (mean score 1.57 and nano-ionomer glass ionomer cement (mean score 2.57. Conclusion: The conventional glassionomer, resin modified glassionomer, and nano-ionomer glassionomer showed micro leakage as filling material in primary teeth cavity. The micro leakage among three types was not significant difference. All three material were comparable in performance and can be used for filling material but still needs a coating material to fill the microleakage.Latar belakang: Semen ionomer kaca adalah salah satu dari banyak bahan gigi yang banyak digunakan dalam praktek kedokteran gigi anak karena bahan tersebut merilis fluoride dan berikatan kimia dengan struktur gigi. Perlekatan bahan tumpatan pada dinding kavitas adalah salah satu karakteristik paling penting yang perlu diteliti efeknya terhadap

  14. UV plasmonic enhancement through three dimensional nano-cavity antenna array in aluminum

    Science.gov (United States)

    Mao, Jieying; Stevenson, Peter; Montanaric, Danielle; Wang, Yunshan; Shumaker-Parry, Jennifer S.; Harris, Joel M.; Blair, Steve

    2017-08-01

    Metallic nanostructure can enhance fluorescence through excited surface plasmons which increase the local field as well as improve its quantum efficiency. When coupling to cavity resonance with proper gap dimension, gap hot spots can be generated to interact with fluorescence at their excitation/emission region in UV. A 3D nano-cavity antenna array in Aluminum has been conducted to generate local hot spot resonant at fluorescence emission resonance. Giant field enhancement has been achieved through coupling fundamental resonance modes of nanocavity into surface plasmons polaritons (SPPs). In this work, two distinct plasmonic structure of 3D resonant cavity nanoantenna has been studied and its plasmonic response has been scaled down to the UV regime through finite-difference-time-domain (FDTD) method. Two different strategies for antenna fabrication will be conducted to obtain D-coupled Dots-on-Pillar Antenna array (D2PA) through Focus Ion Beam (FIB) and Cap- Hole Pair Antenna array (CHPA) through nanosphere template lithography (NTL). With proper optimization of the structures, D2PA and CHPA square array with 280nm pitch have achieved distinct enhancement at fluorophore emission wavelength 350nm and excitation wavelength 280nm simultaneously. Maximum field enhancement can reach 20 and 65 fold in the gap of D2PA and CHPA when light incident from substrate, which is expected to greatly enhance fluorescent quantum efficiency that will be confirmed in fluorescence lifetime measurement.

  15. Development of superconducting cavities at JAERI

    International Nuclear Information System (INIS)

    Ouchi, N.

    2001-01-01

    Development of superconducting (SC) cavities is continued for the high intensity proton accelerator in JAERI. In FY-1999, we carried out R and D work; (1) 2nd vertical test of β=0.886 single-cell cavity, (2) vertical test for observation of Q-disease without heat treatment after electropolishing, (3) vertical test of β=0.5 5-cell cavity, (4) pretuning, surface treatment and vertical test of β=0.886 5-cell cavity, (5) pulsed operation of β=0.886 single-cell cavity in the vertical test to confirm the validity of a new model calculation. This paper describes the present status of the R and D work for the SC cavities in JAERI. (author)

  16. Evaluation of bond strength of silorane and methacrylate based restorative systems to dentin using different cavity models

    Directory of Open Access Journals (Sweden)

    Stephano Zerlottini Isaac

    2013-09-01

    Full Text Available OBJECTIVE: The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS to dentin of two different restorative systems: silorane-based (P90, and methacrylate-based (P60, using two cavity models. MATERIAL AND METHODS: Occlusal enamel of 40 human third molars was removed to expose flat dentin surface. Class I cavities with 4 mm mesial-distal width, 3 mm buccal-lingual width and 3 mm depth (C-factor=4.5 were prepared in 20 teeth, which were divided into two groups (n=10 restored with P60 and P90, bulk-filled after dentin treatment according to manufacturer's instructions. Flat buccal dentin surfaces were prepared in the 20 remaining teeth (C-factor=0.2 and restored with resin blocks measuring 4x3x3 mm using the two restorative systems (n=10. The teeth were sectioned into samples with area between 0.85 and 1.25 mm2 that were submitted to µTBS testing, using a universal testing machine (EMIC at speed of 0.5 mm/min. Fractured specimens were analyzed under stereomicroscope and categorized according to fracture pattern. Data were analyzed using ANOVA and Tukey Kramer tests. RESULTS: For flat surfaces, P60 obtained higher bond strength values compared with P90. However, for Class I cavities, P60 showed significant reduction in bond strength (p0.05, or between Class I Cavity and Flat Surface group, considering P90 restorative system (p>0.05. Regarding fracture pattern, there was no statistical difference among groups (p=0.0713 and 56.3% of the fractures were adhesive. CONCLUSION: It was concluded that methacrylate-based composite µTBS was influenced by cavity models, and the use of silorane-based composite led to similar bond strength values compared to the methacrylate-based composite in cavities with high C-factor.

  17. accelerating cavity from LEP

    CERN Multimedia

    This is an accelerating cavity from LEP, with a layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities are now used in LEP to double the energy of the particle beams.

  18. Fundamental limitations of cavity-assisted atom interferometry

    Science.gov (United States)

    Dovale-Álvarez, M.; Brown, D. D.; Jones, A. W.; Mow-Lowry, C. M.; Miao, H.; Freise, A.

    2017-11-01

    Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

  19. Optimization of photonic crystal cavities

    DEFF Research Database (Denmark)

    Wang, Fengwen; Sigmund, Ole

    2017-01-01

    We present optimization of photonic crystal cavities. The optimization problem is formulated to maximize the Purcell factor of a photonic crystal cavity. Both topology optimization and air-hole-based shape optimization are utilized for the design process. Numerical results demonstrate...... that the Purcell factor of the photonic crystal cavity can be significantly improved through optimization....

  20. TESLA superconducting RF cavity development

    International Nuclear Information System (INIS)

    Koepke, K.

    1995-01-01

    The TESLA collaboration has made steady progress since its first official meeting at Cornell in 1990. The infrastructure necessary to assemble and test superconducting rf cavities has been installed at the TESLA Test Facility (TTF) at DESY. 5-cell, 1.3 GHz cavities have been fabricated and have reached accelerating fields of 25 MV/m. Full sized 9-cell copper cavities of TESLA geometry have been measured to verify the higher order modes present and to evaluate HOM coupling designs. The design of the TESLA 9-cell cavity has been finalized and industry has started delivery. Two prototype 9-cell niobium cavities in their first tests have reached accelerating fields of 10 MV/m and 15 MV/m in a vertical dewar after high peak power (HPP) conditioning. The first 12 m TESLA cryomodule that will house 8 9-cell cavities is scheduled to be delivered in Spring 1995. A design report for the TTF is in progress. The TTF test linac is scheduled to be commissioned in 1996/1997. (orig.)

  1. An economical wireless cavity-nest viewer

    Science.gov (United States)

    Daniel P. Huebner; Sarah R. Hurteau

    2007-01-01

    Inspection of cavity nests and nest boxes is often required during studies of cavity-nesting birds, and fiberscopes and pole-mounted video cameras are sometimes used for such inspection. However, the cost of these systems may be prohibitive for some potential users. We describe a user-built, wireless cavity viewer that can be used to access cavities as high as 15 m and...

  2. Natural convection with evaporation in a vertical cylindrical cavity under the effect of temperature-dependent surface tension

    Science.gov (United States)

    Kozhevnikov, Danil A.; Sheremet, Mikhail A.

    2018-01-01

    The effect of surface tension on laminar natural convection in a vertical cylindrical cavity filled with a weak evaporating liquid has been analyzed numerically. The cylindrical enclosure is insulated at the bottom, heated by a constant heat flux from the side, and cooled by a non-uniform evaporative heat flux from the top free surface having temperature-dependent surface tension. Governing equations with corresponding boundary conditions formulated in dimensionless stream function, vorticity, and temperature have been solved by finite difference method of the second-order accuracy. The influence of Rayleigh number, Marangoni number, and aspect ratio on the liquid flow and heat transfer has been studied. Obtained results have revealed that the heat transfer rate at free surface decreases with Marangoni number and increases with Rayleigh number, while the average temperature inside the cavity has an opposite behavior; namely, it growths with Marangoni number and reduces with Rayleigh number.

  3. Forward Modeling of a Coronal Cavity

    Science.gov (United States)

    Kucera, T. A.; Gibson, S. E.; Schmit, D. J.

    2011-01-01

    We apply a forward model of emission from a coronal cavity in an effort to determine the temperature and density distribution in the cavity. Coronal cavities are long, low-density structures located over filament neutral lines and are often seen as dark elliptical features at the solar limb in white light, EUV and X-rays. When these structures erupt they form the cavity portions of CMEs The model consists of a coronal streamer model with a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. Temperature and density can be varied as a function of altitude both in the cavity and streamer. We apply this model to a cavity observed in Aug. 2007 by a wide array of instruments including Hinode/EIS, STEREO/EUVI and SOHO/EIT. Studies such as these will ultimately help us understand the the original structures which erupt to become CMEs and ICMES, one of the prime Solar Orbiter objectives.

  4. Technical tasks in superconducting cavities

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Kenji [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    1997-11-01

    The feature of superconducting rf cavities is an extremely small surface resistance on the wall. It brings a large energy saving in the operation, even those are cooled with liquid helium. That also makes possible to operate themselves in a higher field gradient comparing to normal conducting cavities, and brings to make accelerators compact. These merits are very important for the future accelerator engineering which is planed at JAERI for the neutron material science and nuclear waste transmutation. This machine is a high intensity proton linac and uses sc cavities in the medium and high {beta} sections. In this paper, starting R and D of proton superconducting cavities, several important technical points which come from the small surface resistance of sc cavities, are present to succeed it and also differences between the medium and high - {beta} structures are discussed. (author)

  5. Optically coupled cavities for wavelength switching

    Energy Technology Data Exchange (ETDEWEB)

    Costazo-Caso, Pablo A; Granieri, Sergio; Siahmakoun, Azad, E-mail: pcostanzo@ing.unlp.edu.ar, E-mail: granieri@rose-hulman.edu, E-mail: siahmako@rose-hulman.edu [Department of Physics and Optical Engineering, Rose-Hulman Institute of Technology, 5500 Wabash Avenue, Terre Haute, IN 47803 (United States)

    2011-01-01

    An optical bistable device which presents hysteresis behavior is proposed and experimentally demonstrated. The system finds applications in wavelength switching, pulse reshaping and optical bistability. It is based on two optically coupled cavities named master and slave. Each cavity includes a semiconductor optical amplifier (SOA), acting as the gain medium of the laser, and two pair of fiber Bragg gratings (FBG) which define the lasing wavelength (being different in each cavity). Finally, a variable optical coupler (VOC) is employed to couple both cavities. Experimental characterization of the system performance is made analyzing the effects of the coupling coefficient between the two cavities and the driving current in each SOA. The properties of the hysteretic bistable curve and switching can be controlled by adjusting these parameters and the loss in the cavities. By selecting the output wavelength ({lambda}{sub 1} or {lambda}{sub 2}) with an external filter it is possible to choose either the invert or non-invert switched signal. Experiments were developed employing both optical discrete components and a photonic integrated circuit. They show that for 8 m-long cavities the maximum switching frequency is about 500 KHz, and for 4 m-long cavities a minimum rise-time about 21 ns was measured. The switching time can be reduced by shortening the cavity lengths and using photonic integrated circuits.

  6. Self-Assembly of Chip-Size Components with Cavity Structures: High-Precision Alignment and Direct Bonding without Thermal Compression for Hetero Integration

    Directory of Open Access Journals (Sweden)

    Mitsumasa Koyanagi

    2011-02-01

    Full Text Available New surface mounting and packaging technologies, using self-assembly with chips having cavity structures, were investigated for three-dimensional (3D and hetero integration of complementary metal-oxide semiconductors (CMOS and microelectromechanical systems (MEMS. By the surface tension of small droplets of 0.5 wt% hydrogen fluoride (HF aqueous solution, the cavity chips, with a side length of 3 mm, were precisely aligned to hydrophilic bonding regions on the surface of plateaus formed on Si substrates. The plateaus have micro-channels to readily evaporate and fully remove the liquid from the cavities. The average alignment accuracy of the chips with a 1 mm square cavity was found to be 0.4 mm. The alignment accuracy depends, not only on the area of the bonding regions on the substrates and the length of chip periphery without the widths of channels in the plateaus, but also the area wetted by the liquid on the bonding regions. The precisely aligned chips were then directly bonded to the substrates at room temperature without thermal compression, resulting in a high shear bonding strength of more than 10 MPa.

  7. Scheme for the implementation of a universal quantum cloning machine via cavity-assisted atomic collisions in cavity QED

    International Nuclear Information System (INIS)

    Zou Xubo; Pahlke, K.; Mathis, W.

    2003-01-01

    We propose a scheme to implement the 1→2 universal quantum cloning machine of Buzek and Hillery [Phys. Rev. A 54, 1844 (1996)] in the context of cavity QED. The scheme requires cavity-assisted collision processes between atoms, which cross through nonresonant cavity fields in the vacuum states. The cavity fields are only virtually excited to face the decoherence problem. That's why the requirements on the cavity quality factor can be loosened

  8. LHC crab-cavity aspects and strategy

    International Nuclear Information System (INIS)

    Calaga, R.; Tomas, R.; Zimmermann, F.

    2010-01-01

    The 3rd LHC Crab Cavity workshop (LHC-CC09) took place at CERN in October 2009. It reviewed the current status and identified a clear strategy towards a future crab-cavity implementation. Following the success of crab cavities in KEK-B and the strong potential for luminosity gain and leveling, CERN will pursue crab crossing for the LHC upgrade. We present a summary and outcome of the variousworkshop sessions which have led to the LHC crab-cavity strategy, covering topics like layout, cavity design, integration, machine protection, and a potential validation test in the SPS.

  9. Nuclear reactor cavity streaming shield

    International Nuclear Information System (INIS)

    Klotz, R.J.; Stephen, D.W.

    1978-01-01

    The upper portion of a nuclear reactor vessel supported in a concrete reactor cavity has a structure mounted below the top of the vessel between the outer vessel wall and the reactor cavity wall which contains hydrogenous material which will attenuate radiation streaming upward between vessel and the reactor cavity wall while preventing pressure buildup during a loss of coolant accident

  10. Offline estimation of decay time for an optical cavity with a low pass filter cavity model.

    Science.gov (United States)

    Kallapur, Abhijit G; Boyson, Toby K; Petersen, Ian R; Harb, Charles C

    2012-08-01

    This Letter presents offline estimation results for the decay-time constant for an experimental Fabry-Perot optical cavity for cavity ring-down spectroscopy (CRDS). The cavity dynamics are modeled in terms of a low pass filter (LPF) with unity DC gain. This model is used by an extended Kalman filter (EKF) along with the recorded light intensity at the output of the cavity in order to estimate the decay-time constant. The estimation results using the LPF cavity model are compared to those obtained using the quadrature model for the cavity presented in previous work by Kallapur et al. The estimation process derived using the LPF model comprises two states as opposed to three states in the quadrature model. When considering the EKF, this means propagating two states and a (2×2) covariance matrix using the LPF model, as opposed to propagating three states and a (3×3) covariance matrix using the quadrature model. This gives the former model a computational advantage over the latter and leads to faster execution times for the corresponding EKF. It is shown in this Letter that the LPF model for the cavity with two filter states is computationally more efficient, converges faster, and is hence a more suitable method than the three-state quadrature model presented in previous work for real-time estimation of the decay-time constant for the cavity.

  11. Lax-pair operators for squared-sum and squared-difference eigenfunctions

    International Nuclear Information System (INIS)

    Ichikawa, Yoshihiko; Iino, Kazuhiro.

    1984-10-01

    Inter-relationship between various representations of the inverse scattering transformation is established by examining eigenfunctions of Lax-pair operators of the sine-Gordon equation and the modified Korteweg-de Vries equation. In particular, it is shown explicitly that there exists Lax-pair operators for the squared-sum and squared-difference eigenfunctions of the Ablowitz-Kaup-Newell-Segur inverse scattering transformation. (author)

  12. Design of half-reentrant SRF cavities

    International Nuclear Information System (INIS)

    Meidlinger, M.; Grimm, T.L.; Hartung, W.

    2006-01-01

    The shape of a TeSLA inner cell can be improved to lower the peak surface magnetic field at the expense of a higher peak surface electric field by making the cell reentrant. Such a single-cell cavity was designed and tested at Cornell, setting a world record accelerating gradient [V. Shemelin et al., An optimized shape cavity for TESLA: concept and fabrication, 11th Workshop on RF Superconductivity, Travemuende, Germany, September 8-12, 2003; R. Geng, H. Padamsee, Reentrant cavity and first test result, Pushing the Limits of RF Superconductivity Workshop, Argonne National Laboratory, September 22-24, 2004]. However, the disadvantage to a cavity is that liquids become trapped in the reentrant portion when it is vertically hung during high pressure rinsing. While this was overcome for Cornell's single-cell cavity by flipping it several times between high pressure rinse cycles, this may not be feasible for a multi-cell cavity. One solution to this problem is to make the cavity reentrant on only one side, leaving the opposite wall angle at six degrees for fluid drainage. This idea was first presented in 2004 [T.L. Grimm et al., IEEE Transactions on Applied Superconductivity 15(6) (2005) 2393]. Preliminary designs of two new half-reentrant (HR) inner cells have since been completed, one at a high cell-to-cell coupling of 2.1% (high-k cc HR) and the other at 1.5% (low-k cc HR). The parameters of a HR cavity are comparable to a fully reentrant cavity, with the added benefit that a HR cavity can be easily cleaned with current technology

  13. Survival of Direct Posterior Composites With and Without a Bulk Fill Base.

    Science.gov (United States)

    McGuirk, C; Hussain, F; Millar, B J

    2017-09-01

    Direct composite restorations are increasingly popular and a flowable bulk-fill base material (SDR, Dentsply) claims to minimise stress through a more flexible polymerisation process. This retrospective audit of restorations placed in general practice compares SDR based restorations with conventional composite restorations. Restorations were all placed by one operator using a similar clinical technique and were audited as Group G, placed with a conventional layering composite (G-aenial, GC) and Group S which had a bulk-fill base of SDR (Dentsply) and then were covered with G-aenial (GC). Data regarding survival, post-operative sensitivity and mode of failure were recorded and analysed. In total 54 Group S restorations and 71 Group G restorations were followed for a minimum of 24 months. Group S had a 92.6% survival and Group G 93%. Group S was more prone to failure by tooth fracture (p=0.033). In both groups failure was more likely in larger cavities, in both those with an increased number of surfaces (p⟨0.001) and cuspal coverage (p=0.004). There appears to be similar survival of the two techniques in the short-term although there were significantly more tooth fractures in teeth restored with SDR. Copyright© 2017 Dennis Barber Ltd.

  14. Present status of superconducting cavity developments

    Energy Technology Data Exchange (ETDEWEB)

    Ouchi, Nobuo; Kusano, Joichi; Hasegawa, Kazuo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    1997-11-01

    An R and D work of a superconducting (SC) cavity for the high intensity proton linac has begun at JAERI in collaboration with KEK. The RF field calculation and the structural analysis have been made to determine the cavity shape in the proton energy range between 100 and 1500 MeV. The results indicate the feasibility of a SC proton linac. A vertical test stand with clean room, water rinsing system, cavity evacuation pumping system, cryostat and data acquisition system has been installed to demonstrate the cavity performance. A single cell cavity of {beta}=0.5 has been fabricated and tested at the test stand to obtain the Q-value and the maximum surface electric field strength. The measured Q-values have been found to be high enough for our requirement while the field strength was limited to about 75% of the specification by the multipacting. We describe the preliminary design of the SC cavity, the overview of the vertical test stand and experimental results of the single cell cavity. (author)

  15. Irrational Square Roots

    Science.gov (United States)

    Misiurewicz, Michal

    2013-01-01

    If students are presented the standard proof of irrationality of [square root]2, can they generalize it to a proof of the irrationality of "[square root]p", "p" a prime if, instead of considering divisibility by "p", they cling to the notions of even and odd used in the standard proof?

  16. Optical cavity furnace for semiconductor wafer processing

    Science.gov (United States)

    Sopori, Bhushan L.

    2014-08-05

    An optical cavity furnace 10 having multiple optical energy sources 12 associated with an optical cavity 18 of the furnace. The multiple optical energy sources 12 may be lamps or other devices suitable for producing an appropriate level of optical energy. The optical cavity furnace 10 may also include one or more reflectors 14 and one or more walls 16 associated with the optical energy sources 12 such that the reflectors 14 and walls 16 define the optical cavity 18. The walls 16 may have any desired configuration or shape to enhance operation of the furnace as an optical cavity 18. The optical energy sources 12 may be positioned at any location with respect to the reflectors 14 and walls defining the optical cavity. The optical cavity furnace 10 may further include a semiconductor wafer transport system 22 for transporting one or more semiconductor wafers 20 through the optical cavity.

  17. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  18. Study of the use of methanol-filled Er-doped suspended-core fibres in a temperature-sensing ring laser system

    International Nuclear Information System (INIS)

    Martín, J C; Berdejo, V; Vallés, J A; Sánchez-Martín, J A; Díez, A; Andrés, M V

    2013-01-01

    We report on an experimental/numerical investigation into the use of methanol-filled Er-doped suspended-core fibres (SCFs) in temperature-sensing ring laser systems. We have adopted a ring laser configuration that includes an Er-doped SCF as a temperature-dependent attenuator (TDA) with a step-index Er-doped fibre (EDF) as the laser active medium. The laser performance dependence on the temperature was measured both in continuous wave (CW) and transient regimes. CW laser output power and build-up time values are compared with those of similar laser systems based on other types of Er-doped PCFs or using other laser configurations. A notable variation of 0.73% °C −1 was achieved in CW operation. Then, by means of parameters obtained by numerically fitting the experimental results, the potential sensing performance of the laser configuration with an SCF as a TDA is studied. Moreover, two ring cavity laser configurations (with the SCF acting basically as an attenuator or also as the active media) are compared and the influence of the position of the coupler inside the ring cavity and the contribution of the erbium doping to improve the sensor features are analysed. The longer interaction lengths compatible with laser action using the Er-doped SCF as a TDA could provide variations of laser output power up to 8.6% °C −1 for 90 mW pump power and a 1 m methanol-filled SCF. (paper)

  19. Inter-assemblage facilitation: the functional diversity of cavity-producing beetles drives the size diversity of cavity-nesting bees.

    Science.gov (United States)

    Sydenham, Markus A K; Häusler, Lise D; Moe, Stein R; Eldegard, Katrine

    2016-01-01

    Inter-specific interactions are important drivers and maintainers of biodiversity. Compared to trophic and competitive interactions, the role of non-trophic facilitation among species has received less attention. Cavity-nesting bees nest in old beetle borings in dead wood, with restricted diameters corresponding to the body size of the bee species. The aim of this study was to test the hypothesis that the functional diversity of cavity-producing wood boring beetles - in terms of cavity diameters - drives the size diversity of cavity-nesting bees. The invertebrate communities were sampled in 30 sites, located in forested landscapes along an elevational gradient. We regressed the species richness and abundance of cavity nesting bees against the species richness and abundance of wood boring beetles, non-wood boring beetles and elevation. The proportion of cavity nesting bees in bee species assemblage was regressed against the species richness and abundance of wood boring beetles. We also tested the relationships between the size diversity of cavity nesting bees and wood boring beetles. The species richness and abundance of cavity nesting bees increased with the species richness and abundance of wood boring beetles. No such relationship was found for non-wood boring beetles. The abundance of wood boring beetles was also related to an increased proportion of cavity nesting bee individuals. Moreover, the size diversity of cavity-nesting bees increased with the functional diversity of wood boring beetles. Specifically, the mean and dispersion of bee body sizes increased with the functional dispersion of large wood boring beetles. The positive relationships between cavity producing bees and cavity nesting bees suggest that non-trophic facilitative interactions between species assemblages play important roles in organizing bee species assemblages. Considering a community-wide approach may therefore be required if we are to successfully understand and conserve wild bee

  20. Discrete vapour cavity model with improved timing of opening and collapse of cavities

    NARCIS (Netherlands)

    Bergant, A.; Tijsseling, A.S.; Vítkovský, J.P.; Simpson, A.R.; Lambert, M.F.

    2007-01-01

    Transient vaporous cavitation occurs in hydraulic piping systems when the liquid pressure falls to the vapour pressure. Cavitation may occur as a localized vapour cavity (large void fraction) or as distributed vaporous cavitation (small void fraction). The discrete vapour cavity model (DVCM) with

  1. Conduction cooling systems for linear accelerator cavities

    Science.gov (United States)

    Kephart, Robert

    2017-05-02

    A conduction cooling system for linear accelerator cavities. The system conducts heat from the cavities to a refrigeration unit using at least one cavity cooler interconnected with a cooling connector. The cavity cooler and cooling connector are both made from solid material having a very high thermal conductivity of approximately 1.times.10.sup.4 W m.sup.-1 K.sup.-1 at temperatures of approximately 4 degrees K. This allows for very simple and effective conduction of waste heat from the linear accelerator cavities to the cavity cooler, along the cooling connector, and thence to the refrigeration unit.

  2. Pacer processing: cavity inventory relationships

    International Nuclear Information System (INIS)

    Dietz, R.J.; Gritzo, L.A.

    1975-09-01

    The pacer cavity and its associated primary power loop comprise a recirculating system in which materials are introduced by a series of thermonuclear explosions while debris is continuously removed by radioactive decay, sorption phenomena, and deliberate processing. Safe, reliable, and economical realization of the Pacer concept depends on the removal and control of both noxious and valuable by-products of the fusion reaction. Mathematical relationships are developed that describe the quantities of materials that are introduced into the Pacer cavity by a series of discrete events and are removed continuously by processing and decay. An iterative computer program based on these relationships is developed that allows both the total cavity inventory and the amounts of important individual species to be determined at any time during the lifetime of the cavity in order to establish the effects of the thermonuclear event, the cavity, the flow, and various processing parameters on Pacer design requirements

  3. Continuous-wave cavity ringdown spectroscopy based on the control of cavity reflection.

    Science.gov (United States)

    Li, Zhixin; Ma, Weiguang; Fu, Xiaofang; Tan, Wei; Zhao, Gang; Dong, Lei; Zhang, Lei; Yin, Wangbao; Jia, Suotang

    2013-07-29

    A new type of continuous-wave cavity ringdown spectrometer based on the control of cavity reflection for trace gas detection was designed and evaluated. The technique separated the acquisitions of the ringdown event and the trigger signal to optical switch by detecting the cavity reflection and transmission, respectively. A detailed description of the time sequence of the measurement process was presented. In order to avoid the wrong extraction of ringdown time encountered accidentally in fitting procedure, the laser frequency and cavity length were scanned synchronously. Based on the statistical analysis of measured ringdown times, the frequency normalized minimum detectable absorption in the reflection control mode was 1.7 × 10(-9)cm(-1)Hz(-1/2), which was 5.4 times smaller than that in the transmission control mode. However the signal-to-noise ratio of the absorption spectrum was only 3 times improved since the etalon effect existed. Finally, the peak absorption coefficients of the C(2)H(2) transition near 1530.9nm under different pressures showed a good agreement with the theoretical values.

  4. Storage and retrieval of time-entangled soliton trains in a three-level atom system coupled to an optical cavity

    Science.gov (United States)

    Welakuh, Davis D. M.; Dikandé, Alain M.

    2017-11-01

    The storage and subsequent retrieval of coherent pulse trains in the quantum memory (i.e. cavity-dark state) of three-level Λ atoms, are considered for an optical medium in which adiabatic photon transfer occurs under the condition of quantum impedance matching. The underlying mechanism is based on intracavity Electromagnetically-Induced Transparency, by which properties of a cavity filled with three-level Λ-type atoms are manipulated by an external control field. Under the impedance matching condition, we derive analytic expressions that suggest a complete transfer of an input field into the cavity-dark state by varying the mixing angle in a specific way, and its subsequent retrieval at a desired time. We illustrate the scheme by demonstrating the complete transfer and retrieval of a Gaussian, a single hyperbolic-secant and a periodic train of time-entangled hyperbolic-secant input photon pulses in the atom-cavity system. For the time-entangled hyperbolic-secant input field, a total controllability of the periodic evolution of the dark state population is made possible by changing the Rabi frequency of the classical driving field, thus allowing to alternately store and retrieve high-intensity photons from the optically dense Electromagnetically-Induced transparent medium. Such multiplexed photon states, which are expected to allow sharing quantum information among many users, are currently of very high demand for applications in long-distance and multiplexed quantum communication.

  5. A comparison of gap-filling approaches for Landsat-7 satellite data

    KAUST Repository

    Yin, Gaohong

    2017-08-10

    The purpose of this study is to assess the relative performance of four different gap-filling approaches across a range of land-surface conditions, including both homogeneous and heterogeneous areas as well as in scenes with abrupt changes in landscape elements. The techniques considered in this study include: (1) Kriging and co-Kriging; (2) geostatistical neighbourhood similar pixel interpolator (GNSPI); (3) a weighted linear regression (WLR) algorithm; and (4) the direct sampling (DS) method. To examine the impact of image availability and the influence of temporal distance on the selection of input training data (i.e. time separating the training data from the gap-filled target image), input images acquired within the same season (temporally close) as well as in different seasons (temporally far) to the target image were examined, as was the case of using information only within the target image itself. Root mean square error (RMSE), mean spectral angle (MSA), and coefficient of determination (R-2) were used as the evaluation metrics to assess the prediction results. In addition, the overall accuracy (OA) and kappa coefficient (kappa) were used to assess a land-cover classification based on the gap-filled images. Results show that all of the gap-filling approaches provide satisfactory results for the homogeneous case, with R-2 > 0.93 for bands 1 and 2 in all cases and R-2 > 0.80 for bands 3 and 4 in most cases. For the heterogeneous example, GNSPI performs the best, with R-2 > 0.85 for all tested cases. WLR and GNSPI exhibit equivalent accuracy when a temporally close input image is used (i.e. WLR and GNSPI both have an R-2 equal to 0.89 for band 1). For the case of abrupt changes in scene elements or in the absence of ancillary data, the DS approach outperforms the other tested methods.

  6. A comparison of gap-filling approaches for Landsat-7 satellite data

    KAUST Repository

    Yin, Gaohong; Mariethoz, Gregoire; Sun, Ying; McCabe, Matthew

    2017-01-01

    The purpose of this study is to assess the relative performance of four different gap-filling approaches across a range of land-surface conditions, including both homogeneous and heterogeneous areas as well as in scenes with abrupt changes in landscape elements. The techniques considered in this study include: (1) Kriging and co-Kriging; (2) geostatistical neighbourhood similar pixel interpolator (GNSPI); (3) a weighted linear regression (WLR) algorithm; and (4) the direct sampling (DS) method. To examine the impact of image availability and the influence of temporal distance on the selection of input training data (i.e. time separating the training data from the gap-filled target image), input images acquired within the same season (temporally close) as well as in different seasons (temporally far) to the target image were examined, as was the case of using information only within the target image itself. Root mean square error (RMSE), mean spectral angle (MSA), and coefficient of determination (R-2) were used as the evaluation metrics to assess the prediction results. In addition, the overall accuracy (OA) and kappa coefficient (kappa) were used to assess a land-cover classification based on the gap-filled images. Results show that all of the gap-filling approaches provide satisfactory results for the homogeneous case, with R-2 > 0.93 for bands 1 and 2 in all cases and R-2 > 0.80 for bands 3 and 4 in most cases. For the heterogeneous example, GNSPI performs the best, with R-2 > 0.85 for all tested cases. WLR and GNSPI exhibit equivalent accuracy when a temporally close input image is used (i.e. WLR and GNSPI both have an R-2 equal to 0.89 for band 1). For the case of abrupt changes in scene elements or in the absence of ancillary data, the DS approach outperforms the other tested methods.

  7. Design of rf conditioner cavities

    International Nuclear Information System (INIS)

    Govil, R.; Rimmer, R.A.; Sessler, A.; Kirk, H.G.

    1992-06-01

    Theoretical studies are made of radio frequency structures which can be used to condition electron beams so as to greatly reduce the stringent emittance requirements for successful lasing in a free-electron laser. The basic strategy of conditioning calls for modulating an electron beam in the transverse dimension, by a periodic focusing channel, while it traverses a series of rf cavities, each operating in a TM 210 mode. In this paper, we analyze the cavities both analytically and numerically (using MAFIA simulations). We find that when cylindrical symmetry is broken the coupling impedance can be greatly enhanced. We present results showing various performance characteristics as a function of cavity parameters, as well as possible designs for conditioning cavities

  8. Cavity QED with single trapped Ca+-ions

    International Nuclear Information System (INIS)

    Mundt, A.B.

    2003-02-01

    This thesis reports on the design and setup of a vacuum apparatus allowing the investigation of cavity QED effects with single trapped 40 Ca + ions. The weak coupling of ion and cavity in the 'bad cavity limit' may serve to inter--convert stationary and flying qubits. The ion is confined in a miniaturized Paul trap and cooled via the Doppler effect to the Lamb--Dicke regime. The extent of the atomic wave function is less than 30 nm. The ion is enclosed by a high finesse optical cavity. The technically--involved apparatus allows movement of the trap relative to the cavity and the trapped ion can be placed at any position in the standing wave. By means of a transfer lock the cavity can be resonantly stabilized with the S 1/2 ↔ D 5/2 quadrupole transition at 729 nm (suitable as a qubit) without light at that wavelength being present in the cavity. The coupling of the cavity field to the S 1/2 ↔ D 5/2 quadrupole transition is investigated with various techniques in order to determine the spatial dependence as well as the temporal dynamics. The orthogonal coupling of carrier and first--order sideband transitions at field nodes and antinodes is explored. The coherent interaction of the ion and the cavity field is confirmed by exciting Rabi oscillations with short resonant pulses injected into the cavity. Finally, first experimental steps towards the observation of cavity enhanced spontaneous emission have been taken. (author)

  9. Voltage control of cavity magnon polariton

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, S., E-mail: kaurs3@myumanitoba.ca; Rao, J. W.; Gui, Y. S.; Hu, C.-M., E-mail: hu@physics.umanitoba.ca [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Yao, B. M. [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); National Laboratory for Infrared Physics, Chinese Academy of Sciences, Shanghai 200083 (China)

    2016-07-18

    We have experimentally investigated the microwave transmission of the cavity-magnon-polariton (CMP) generated by integrating a low damping magnetic insulator onto a 2D microwave cavity. The high tunability of our planar cavity allows the cavity resonance frequency to be precisely controlled using a DC voltage. By appropriately tuning the voltage and magnetic bias, we can observe the cavity photon magnon coupling and the magnetic coupling between a magnetostatic mode and the generated CMP. The dispersion of the generated CMP was measured by either tuning the magnetic field or the applied voltage. This electrical control of CMP may open up avenues for designing advanced on-chip microwave devices that utilize light-matter interaction.

  10. Cavity pressure history of contained nuclear explosions

    Energy Technology Data Exchange (ETDEWEB)

    Chapin, C E [Lawrence Radiation Laboratory, University of California, Livermore, CA (United States)

    1970-05-01

    Knowledge of pressure in cavities created by contained nuclear explosions is useful for estimating the possibility of venting radioactive debris to the atmosphere. Measurements of cavity pressure, or temperature, would be helpful in evaluating the correctness of present code predictions of underground explosions. In instrumenting and interpreting such measurements it is necessary to have good theoretical estimates of cavity pressures. In this paper cavity pressure is estimated at the time when cavity growth is complete. Its subsequent decrease due to heat loss from the cavity to the surrounding media is also predicted. The starting pressure (the pressure at the end of cavity growth) is obtained by adiabatic expansion to the final cavity size of the vaporized rock gas sphere created by the explosion. Estimates of cavity size can be obtained by stress propagation computer codes, such as SOC and TENSOR. However, such estimates require considerable time and effort. In this paper, cavity size is estimated using a scheme involving simple hand calculations. The prediction is complicated by uncertainties in the knowledge of silica water system chemistry and a lack of information concerning possible blowoff of wall material during cavity growth. If wall material blows off, it can significantly change the water content in the cavity, compared to the water content in the ambient media. After cavity growth is complete, the pressure will change because of heat loss to the surrounding media. Heat transfer by convection, radiation and conduction is considered, and its effect on the pressure is calculated. Analysis of cavity heat transfer is made difficult by the complex nature of processes which occur at the wall where melting, vaporization and condensation of the gaseous rock can all occur. Furthermore, the melted wall material could be removed by flowing or dripping to the cavity floor. It could also be removed by expansion of the steam contained in the melt (blowoff) and by

  11. Square through tube

    International Nuclear Information System (INIS)

    Akita, Junji; Honma, Toei.

    1975-01-01

    Object: To provide a square through tube involving thermal movement in pipelines such as water supply pump driving turbine exhaust pipe (square-shaped), which is wide in freedom with respect to shape and dimension thereof for efficient installation at site. Structure: In a through tube to be airtightly retained for purpose of decontamination in an atomic power plant, comprising a seal rubber plate, a band and a bolt and a nut for securing said plate, the seal rubber plate being worked into the desired shape so that it may be placed in intimate contact with the concrete floor surface by utilization of elasticity of rubber, thereby providing airtightness at a corner portion of the square tube. (Kamimura, M.)

  12. Complications of cataract surgery in eyes filled with silicone oil.

    Science.gov (United States)

    Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł

    2018-03-01

    The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

  13. The effects of polymers' visco-elastoplastic properties on the micro cavities filling step of hot embossing process

    Science.gov (United States)

    Cheng, Gang; Barrière, Thierry

    2018-05-01

    The hot embossing process has been widely used in the manufacturing of polymer components, especially for the fabrication of micro or nano components. The significant advantage of the hot embossing process compared to the traditional injection moulding process is the excellent effective filling ratio for the high aspect ratio components and large surface structural components. The lack of material behavior modeling and numerical simulation limits the further development the hot embossing process, especially at the micro and nano scales. In this paper, a visco-elastoplastic behavior law has been proposed to describe the amorphous thermoplastic polymer mechanical properties in the hot embossing processing temperature range, which is lightly above their glass transition temperature. Uniaxial compression tests have been carried out in order to investigate the amorphous thermoplastic polymers properties. The material parameters in the visco-elastoplastic model have been identified according to the experimental results. A 3D numerical model has been created in the simulation software, which is based on the finite element method. The numerical simulation of the filling step of the hot embossing process has been effectuated by taking into account the viscous, elastic and plastic behaviors of thermoplastic polymers. The micro hot embossing process has been carried out using horizontal injection compression moulding equipment. A complete compression mould tool, equipped with the heating system, the cooling system, the ejection system and the vacuum system, has been designed and elaborated for this research work. The microfluidic devices based on the amorphous thermoplastic polymers have been successfully elaborated by hot embossing process. Proper agreement between the numerical simulation and the experimental elaboration has been obtained.

  14. Image transmission through a stable paraxial cavity

    International Nuclear Information System (INIS)

    Gigan, Sylvain; Lopez, Laurent; Treps, Nicolas; Maitre, Agnes; Fabre, Claude

    2005-01-01

    We study the transmission of a monochromatic 'image' through a paraxial cavity. Using the formalism of self-transform functions, we show that a transverse degenerate cavity transmits the self-transform part of the image, with respect to the field transformation over one round-trip of the cavity. This formalism gives insight into the understanding of the behavior of a transverse degenerate cavity, complementary to the transverse mode picture. An experiment of image transmission through a hemiconfocal cavity shows the interest of this approach

  15. Numerical study of wave propagation around an underground cavity: acoustic case

    Science.gov (United States)

    Esterhazy, Sofi; Perugia, Ilaria; Schöberl, Joachim; Bokelmann, Götz

    2015-04-01

    Motivated by the need to detect an underground cavity within the procedure of an On-Site-Inspection (OSI) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO), which might be caused by a nuclear explosion/weapon testing, we aim to provide a basic numerical study of the wave propagation around and inside such an underground cavity. The aim of the CTBTO is to ban all nuclear explosions of any size anywhere, by anyone. Therefore, it is essential to build a powerful strategy to efficiently investigate and detect critical signatures such as gas filled cavities, rubble zones and fracture networks below the surface. One method to investigate the geophysical properties of an underground cavity allowed by the Comprehensive Nuclear-test Ban Treaty is referred to as 'resonance seismometry' - a resonance method that uses passive or active seismic techniques, relying on seismic cavity vibrations. This method is in fact not yet entirely determined by the Treaty and there are also only few experimental examples that have been suitably documented to build a proper scientific groundwork. This motivates to investigate this problem on a purely numerical level and to simulate these events based on recent advances in the mathematical understanding of the underlying physical phenomena. Here, we focus our numerical study on the propagation of P-waves in two dimensions. An extension to three dimensions as well as an inclusion of the full elastic wave field is planned in the following. For the numerical simulations of wave propagation we use a high order finite element discretization which has the significant advantage that it can be extended easily from simple toy designs to complex and irregularly shaped geometries without excessive effort. Our computations are done with the parallel Finite Element Library NGSOLVE ontop of the automatic 2D/3D tetrahedral mesh generator NETGEN (http://sourceforge.net/projects/ngsolve/). Using the basic mathematical understanding of the

  16. Weighted conditional least-squares estimation

    International Nuclear Information System (INIS)

    Booth, J.G.

    1987-01-01

    A two-stage estimation procedure is proposed that generalizes the concept of conditional least squares. The method is instead based upon the minimization of a weighted sum of squares, where the weights are inverses of estimated conditional variance terms. Some general conditions are given under which the estimators are consistent and jointly asymptotically normal. More specific details are given for ergodic Markov processes with stationary transition probabilities. A comparison is made with the ordinary conditional least-squares estimators for two simple branching processes with immigration. The relationship between weighted conditional least squares and other, more well-known, estimators is also investigated. In particular, it is shown that in many cases estimated generalized least-squares estimators can be obtained using the weighted conditional least-squares approach. Applications to stochastic compartmental models, and linear models with nested error structures are considered

  17. New achievements in RF cavity manufacturing

    International Nuclear Information System (INIS)

    Lippmann, G.; Pimiskern, K.; Kaiser, H.

    1993-01-01

    Dornier has been engaged in development, manufacturing and testing of Cu-, Cu/Nb- and Nb-cavities for many years. Recently, several different types of RF cavities were manufactured. A prototype superconducting (s.c.) B-Factory accelerating cavity (1-cell, 500 MHz) was delivered to Cornell University, Laboratory of Nuclear Studies. A second lot of 6 s.c. cavities (20-cell, 3000 MHz) was fabricated on contract from Technical University of Darmstadt for the S-DALINAC facility. Finally, the first copper RF structures (9-cell, 1300 MHz) for TESLA were finished and delivered to DESY, two s.c. niobium structures of the same design are in production. Highlights from the manufacturing processes of these cavities are described and first performance results will be reported

  18. Cryostat for TRISTAN superconducting cavity

    International Nuclear Information System (INIS)

    Mitsunobu, S.; Furuya, T.; Hara, K.

    1990-01-01

    Superconducting cavities generate rather high heat load of hundreds watts in one cryostat and have high sensitivity for pressure. We adopted usual pool-boiling type cooling for its stable pressure operation. Two 5-cell Nb cavities were installed in one flange type cryostat. Tuning mechanics actuated by a pulse-motor and a Piezo-electric element are set at outside of vacuum end flange. The design and performance of the cryostat for TRISTAN superconducting cavities are described. (author)

  19. Thermodynamics of Pore Filling Metal Clusters in Metal Organic Frameworks: Pd in UiO-66

    DEFF Research Database (Denmark)

    Vilhelmsen, Lasse; Sholl, David S.

    2012-01-01

    Metal organic frameworks (MOFs) have experimentally been demonstrated to be capable of supporting isolated transition-metal clusters, but the stability of these clusters with respect to aggregation is unclear. In this letter we use a genetic algorithm together with density functional theory...... calculations to predict the structure of Pd clusters in UiO-66. The cluster sizes examined are far larger than those in any previous modeling studies of metal clusters in MOFs and allow us to test the hypothesis that the physically separated cavities in UiO-66 could stabilize isolated Pd clusters. Our...... calculations show that Pd clusters in UiO-66 are, at best, metastable and will aggregate into connected pore filling structures at equilibrium....

  20. The structure of filled skutterudites and the local vibration behavior of the filling atom

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiaojuan [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zong, Peng-an [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Chen, Xihong [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Tao, Juzhou, E-mail: taoj@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); Lin, He, E-mail: linhe@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201204 (China)

    2017-02-15

    Both of atomic pair distribution function (PDF) and extended x-ray absorption fine structure (EXAFS) experiments have been carried out on unfilled and Yb-filled skutterudites Yb{sub x}Co{sub 4}Sb{sub 12} (x=0, 0.15, 0.2 and 0.25) samples. The structure refinements on PDF data confirm the large amplitude vibration of Yb atom and the dependence of Yb vibration amplitude on the filling content. Temperature dependent EXAFS experiment on filled skutterudites have been carried out at Yb L{sub Ⅲ}-edge in order to explore the local vibration behavior of filled atom. EXAFS experiments show that the Einstein temperature of the filled atom is very low (70.9 K) which agrees with the rattling behavior.

  1. Square-root measurement for pure states

    International Nuclear Information System (INIS)

    Huang Siendong

    2005-01-01

    Square-root measurement is a very useful suboptimal measurement in many applications. It was shown that the square-root measurement minimizes the squared error for pure states. In this paper, the least squared error problem is reformulated and a new proof is provided. It is found that the least squared error depends only on the average density operator of the input states. The properties of the least squared error are then discussed, and it is shown that if the input pure states are uniformly distributed, the average probability of error has an upper bound depending on the least squared error, the rank of the average density operator, and the number of the input states. The aforementioned properties help explain why the square-root measurement can be effective in decoding processes

  2. Fluid Density and Impact Cavity Formation

    Directory of Open Access Journals (Sweden)

    Ga-Chun Lin

    2018-01-01

    Full Text Available Characteristics of the impact cavity formed when a steel ball is dropped into aqueous solutions of densities ranging from 0.98 g·cm-3 to 1.63 g·cm-3 were investigated. A high-speed camera was used to record the formation and collapse of the cavity. The results showed cavity diameter, volume, and pinch-off time are independent of fluid density, on average. There was an unexplained reduction in cavity formation for densities of 1.34 g·cm-3 and 1.45 g·cm-3.

  3. LARGE-SCALE FLOWS IN PROMINENCE CAVITIES

    International Nuclear Information System (INIS)

    Schmit, D. J.; Gibson, S. E.; Tomczyk, S.; Reeves, K. K.; Sterling, Alphonse C.; Brooks, D. H.; Williams, D. R.; Tripathi, D.

    2009-01-01

    Regions of rarefied density often form cavities above quiescent prominences. We observed two different cavities with the Coronal Multichannel Polarimeter on 2005 April 21 and with Hinode/EIS on 2008 November 8. Inside both of these cavities, we find coherent velocity structures based on spectral Doppler shifts. These flows have speeds of 5-10 km s -1 , occur over length scales of tens of megameters, and persist for at least 1 hr. Flows in cavities are an example of the nonstatic nature of quiescent structures in the solar atmosphere.

  4. Demountable damped cavity for HOM-damping in ILC superconducting accelerating cavities

    Energy Technology Data Exchange (ETDEWEB)

    Konomi, T., E-mail: konomi@ims.ac.jp [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Yasuda, F. [University of Tokyo, Bunkyo-ku, Tokyo 113-8654 (Japan); Furuta, F. [Laboratory for Elementary-Particle Physics, Cornell University, Ithaca, NY 14853 (United States); Saito, K. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2014-01-11

    We have designed a new higher-order-mode (HOM) damper called a demountable damped cavity (DDC) as part of the R and D efforts for the superconducting cavity of the International Linear Collider (ILC). The DDC has two design concepts. The first is an axially symmetrical layout to obtain high damping efficiency. The DDC has a coaxial structure along the beam axis to realize strong coupling with HOMs. HOMs are damped by an RF absorber at the end of the coaxial waveguide and the accelerating mode is reflected by a choke filter mounted at the entrance of the coaxial waveguide. The second design concept is a demountable structure to facilitate cleaning, in order to suppress the Q-slope problem in a high field. A single-cell cavity with the DDC was fabricated to test four performance parameters. The first was frequency matching between the accelerating cavity and the choke filter. Since the bandwidth of the resonance frequency in a superconducting cavity is very narrow, there is a possibility that the accelerating field will leak to the RF absorber because of thermal shrinkage. The design bandwidth of the choke filter is 25 kHz. It was demonstrated that frequency matching adjusted at room temperature could be successfully maintained at 2 K. The second parameter was the performance of the demountable structure. At the joint, the magnetic field is 1/6 of the maximum field in the accelerating cavity. Ultimately, the accelerating field reached 19 MV/m and Q{sub 0} was 1.5×10{sup 10} with a knife-edge shape. The third parameter was field emission and multipacting. Although the choke structure has numerous parallel surfaces that are susceptible to the multipacting problem, it was found that neither field emission nor multipacting presented problems in both an experiment and simulation. The final parameter was the Q values of the HOM. The RF absorber adopted in the system is a Ni–Zn ferrite type. The RF absorber shape was designed based on the measurement data of permittivity

  5. Demountable damped cavity for HOM-damping in ILC superconducting accelerating cavities

    International Nuclear Information System (INIS)

    Konomi, T.; Yasuda, F.; Furuta, F.; Saito, K.

    2014-01-01

    We have designed a new higher-order-mode (HOM) damper called a demountable damped cavity (DDC) as part of the R and D efforts for the superconducting cavity of the International Linear Collider (ILC). The DDC has two design concepts. The first is an axially symmetrical layout to obtain high damping efficiency. The DDC has a coaxial structure along the beam axis to realize strong coupling with HOMs. HOMs are damped by an RF absorber at the end of the coaxial waveguide and the accelerating mode is reflected by a choke filter mounted at the entrance of the coaxial waveguide. The second design concept is a demountable structure to facilitate cleaning, in order to suppress the Q-slope problem in a high field. A single-cell cavity with the DDC was fabricated to test four performance parameters. The first was frequency matching between the accelerating cavity and the choke filter. Since the bandwidth of the resonance frequency in a superconducting cavity is very narrow, there is a possibility that the accelerating field will leak to the RF absorber because of thermal shrinkage. The design bandwidth of the choke filter is 25 kHz. It was demonstrated that frequency matching adjusted at room temperature could be successfully maintained at 2 K. The second parameter was the performance of the demountable structure. At the joint, the magnetic field is 1/6 of the maximum field in the accelerating cavity. Ultimately, the accelerating field reached 19 MV/m and Q 0 was 1.5×10 10 with a knife-edge shape. The third parameter was field emission and multipacting. Although the choke structure has numerous parallel surfaces that are susceptible to the multipacting problem, it was found that neither field emission nor multipacting presented problems in both an experiment and simulation. The final parameter was the Q values of the HOM. The RF absorber adopted in the system is a Ni–Zn ferrite type. The RF absorber shape was designed based on the measurement data of permittivity and

  6. Nanometer cavities studied by positron annihilation

    International Nuclear Information System (INIS)

    Mogensen, O.E.

    1992-01-01

    Positronium (Ps) is trapped in cavities in insulating solids, and the lifetime of ortho Ps is determined by the size of the cavity. The information on the properties of the cavities obtained by use of the standard slow positron beam and the 'normal' positron annihilation techniques is compared for several selected cases. (author)

  7. Additive Manufactured Superconducting Cavities

    Science.gov (United States)

    Holland, Eric; Rosen, Yaniv; Woolleet, Nathan; Materise, Nicholas; Voisin, Thomas; Wang, Morris; Mireles, Jorge; Carosi, Gianpaolo; Dubois, Jonathan

    Superconducting radio frequency cavities provide an ultra-low dissipative environment, which has enabled fundamental investigations in quantum mechanics, materials properties, and the search for new particles in and beyond the standard model. However, resonator designs are constrained by limitations in conventional machining techniques. For example, current through a seam is a limiting factor in performance for many waveguide cavities. Development of highly reproducible methods for metallic parts through additive manufacturing, referred to colloquially as 3D printing\\x9D, opens the possibility for novel cavity designs which cannot be implemented through conventional methods. We present preliminary investigations of superconducting cavities made through a selective laser melting process, which compacts a granular powder via a high-power laser according to a digitally defined geometry. Initial work suggests that assuming a loss model and numerically optimizing a geometry to minimize dissipation results in modest improvements in device performance. Furthermore, a subset of titanium alloys, particularly, a titanium, aluminum, vanadium alloy (Ti - 6Al - 4V) exhibits properties indicative of a high kinetic inductance material. This work is supported by LDRD 16-SI-004.

  8. Intra-cavity vortex beam generation

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2011-08-01

    Full Text Available at exploring the methods of generating optical vortex beams. We will discuss a typical extra-cavity approach that harnesses digital holography through the use of a SLM. We consider vortex beam generation as the fundamental mode of a monolithic microchip laser...-cavity phase diffractive elements can result in the desired mode as the fundamental mode of the cavity with pure modal quality. This approach, although very attractive is insufficient for the generation of these modes in monolithic microchip lasers. A...

  9. Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials.

    Science.gov (United States)

    Alcalde, Murilo Priori; Vivan, Rodrigo Ricci; Marciano, Marina Angélica; Duque, Jussaro Alves; Fernandes, Samuel Lucas; Rosseto, Mariana Bailo; Duarte, Marco Antonio Hungaro

    2018-05-01

    This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Sixty maxillary canines were divided into 6 groups ( n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA ( p < 0.05). US improved the push-out bond strength for all the cements ( p < 0.05). The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

  10. Statistics of magnetoconductance in ballistic cavities

    International Nuclear Information System (INIS)

    Yang, X.; Ishio, H.; Burgdoerfer, J.

    1995-01-01

    The statistical properties of magnetoconductance in ballistic microcavities are investigated numerically. The distribution of conductance for chaotic cavities is found to follow the renormalized Porter-Thomas distribution suggested by random-matrix theory for the Gaussian ensemble while the conductance distribution of regular cavities in magnetic fields is nonuniversal and shifted towards the maximum value for a given number of open channels. The renormalized Porter-Thomas distribution implies a universal dependence of fluctuation amplitude on the mean conductance for chaotic cavities in the absence of time-reversal symmetry. The fluctuation amplitude for regular cavities is found to be larger than the saturation value of the fluctuation amplitude of chaotic cavities predicted by random-matrix theory. The change of the mean conductance as a function of the external magnetic field is consistent with semiclassical predictions

  11. Metasurface external cavity laser

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Luyao, E-mail: luyaoxu.ee@ucla.edu; Curwen, Christopher A.; Williams, Benjamin S. [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); California NanoSystems Institute, University of California, Los Angeles, California 90095 (United States); Hon, Philip W. C.; Itoh, Tatsuo [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); Chen, Qi-Sheng [Northrop Grumman Aerospace Systems, Redondo Beach, California 90278 (United States)

    2015-11-30

    A vertical-external-cavity surface-emitting-laser is demonstrated in the terahertz range, which is based upon an amplifying metasurface reflector composed of a sub-wavelength array of antenna-coupled quantum-cascade sub-cavities. Lasing is possible when the metasurface reflector is placed into a low-loss external cavity such that the external cavity—not the sub-cavities—determines the beam properties. A near-Gaussian beam of 4.3° × 5.1° divergence is observed and an output power level >5 mW is achieved. The polarized response of the metasurface allows the use of a wire-grid polarizer as an output coupler that is continuously tunable.

  12. 3D magneto-convective heat transfer in CNT-nanofluid filled cavity under partially active magnetic field

    Science.gov (United States)

    Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur

    2018-05-01

    A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.

  13. Electromagnetic flow control of a bifurcated jet in a rectangular cavity

    International Nuclear Information System (INIS)

    Kalter, R.; Tummers, M.J.; Kenjereš, S.; Righolt, B.W.; Kleijn, C.R.

    2014-01-01

    Highlights: • Self-sustained oscillations in a thin cavity with submerged nozzle were observed. • The self-sustained oscillations were influenced by applying a Lorentz force. • A POD was applied to study the distribution of kinetic energy. • The large scale fluctuations can be enhanced or suppressed by the Lorentz force. • The turbulence fluctuations are not affected by the Lorentz force. - Abstract: The effect of Lorentz forcing on self-sustained oscillations of turbulent jets (Re = 3.1 × 10 3 ) issuing from a submerged bifurcated nozzle into a thin rectangular liquid filled cavity was investigated using free surface visualization and time-resolved particle image velocimetry (PIV). A Lorentz force is produced by applying an electrical current across the width of the cavity in conjunction with a magnetic field. As a working fluid a saline solution is used. The Lorentz force can be directed downward (F L L >0), to weaken or strengthen the self-sustained jet oscillations. The low frequency self-sustained jet oscillations induce a free surface oscillation. When F L L >0 the free surface oscillation amplitude is enhanced by a factor of 1.5. A large fraction of the turbulence kinetic energy k=1/2 u i ′ u i ′‾ is due to the self-sustained jet oscillations. A triple decomposition of the instantaneous velocity was used to divide the turbulence kinetic energy into a part originating from the self-sustained jet oscillation k osc and a part originating from the higher frequency turbulent fluctuations k turb . It follows that the Lorentz force does not influence k turb in the measurement plane, but the distribution of k osc can be altered significantly. The amount of energy contained in the self-sustained oscillation is three times lower when F L L >0

  14. Influence of light-exposure methods and depths of cavity on the microhardness of dual-cured core build-up resin composites

    Directory of Open Access Journals (Sweden)

    Keiichi YOSHIDA

    2014-01-01

    Full Text Available Objective: The purpose of this study was to evaluate the Knoop hardness number (KHN of dual-cured core build-up resin composites (DCBRCs at 6 depths of cavity after 3 post-irradiation times by 4 light-exposure methods. Material and Methods: Five specimens each of DCBRCs (Clearfil DC Core Plus [DCP] and Unifil Core EM [UCE] were filled in acrylic resin blocks with a semi-cylindrical cavity and light-cured using an LED light unit (power density: 1,000 mW/cm2at the top surface by irradiation for 20 seconds (20 s, 40 seconds (40 s, bonding agent plus 20 seconds (B+20 s, or 40 seconds plus light irradiation of both sides of each acrylic resin block for 40 seconds each (120 s. KHN was measured at depths of 0.5, 2.0, 4.0, 6.0, 8.0, and 10.0 mm at 0.5 hours, 24 hours, and 7 days post-irradiation. Statistical analysis was performed using repeated measures ANOVA and Tukey's compromise post-hoc test with a significance level of p0.05. In DCP, and not UCE, at 24 hours and 7 days post-irradiation, the B+20 s method showed significantly higher KHN at all depths of cavity, except the depth of 0.5 mm (p<0.05. Conclusion: KHN depends on the light-exposure method, use of bonding agent, depth of cavity, post-irradiation time, and material brand. Based on the microhardness behavior, DCBRCs are preferably prepared by the effective exposure method, when used for a greater depth of cavity.

  15. Operation feedback of hydrogen filling station

    International Nuclear Information System (INIS)

    Pregassame, S.; Barral, K.; Allidieres, L.; Charbonneau, T.; Lacombe, Y.

    2004-01-01

    One of the technical challenges of hydrogen technology is the development of hydrogen infrastructures which satisfy either safety requirements and reliability of filling processes. AIR LIQUIDE realized an hydrogen filling station in Sassenage (France) operational since September 2003. This station is able to fill 3 buses a day up to 350bar by equilibrium with high pressure buffers. In parallel with commercial stations, the group wanted to create a testing ground in real conditions running with several objectives: validate on a full scale bench a simulation tool able to predict the temperature of both gas and cylinder's materials during filling processes; define the best filling procedures in order to reach mass, temperature and filling time targets; analyse the temperature distribution and evolution inside the cylinder; get a general knowledge about hydrogen stations from safety and reliability point of view; operate the first full scale refuelling station in France. The station is also up-graded for 700bar filling from either a liquid hydrogen source or a gas booster, with cold filling possibility. This paper presents the results concerning 350bar filling : thermal effects, optimal filling procedures and influence of parameters such as climatic conditions are discussed. (author)

  16. Progress on SCRF cavity manufacturing activities at RRCAT

    International Nuclear Information System (INIS)

    Puntambekar, A.; Dwivedi, J.; Mundra, G.; Srivastava, P.; Joshi, S.C.; Gupta, P.D.

    2015-01-01

    The work on development of SCRF cavities and associated technologies is ongoing at RRCAT to support its upcoming projects involving SC LINAC. RRCAT is also a member of Indian Institution Fermilab Collaboration (IIFC) working on development of SCRF cavities and associated technologies. Subsequent to 1.3 GHz single cell SCRF cavities, a 650 MHz single cell, a 1.3 GHz five cell and a 1.3 GHz nine cell SCRF cavities have been fabricated. These were tested for their mechanical, vacuum and RF qualifications at RRCAT for pre qualifications. The 1.3 GHz five cell SCRF cavity and 650 MHz single cell SCRF cavity has been processed and successfully tested at Fermi lab under IIFC. The 1.3 GHz five-cell cavity has achieved E acc of 20.3 MV/m at 2 K and 42 MV/m at 1.5-1.7 K with Q o of 2 x 10 10 . The 650 MHz single cell cavity has achieved the E acc > 19.3 MV/m with Q> 4x 10 10 at 2K. A 15 kW Electron Beam Welding (EBW) Machine has also been installed and commissioned at RRCAT as part of special infrastructure for development of SCRF cavities. One each 1.3 GHz and 650 MHz single cell SCRF cavities have also been fabricated using this EBW facility. Present focus of work is towards development of 650 MHz (β=0.92) multi-cell SCRF cavities. This paper will present the various technology development efforts on SCRF cavity fabrication, cavity test results and future plans. (author)

  17. Computer codes for RF cavity design

    International Nuclear Information System (INIS)

    Ko, K.

    1992-08-01

    In RF cavity design, numerical modeling is assuming an increasingly important role with the help of sophisticated computer codes and powerful yet affordable computers. A description of the cavity codes in use in the accelerator community has been given previously. The present paper will address the latest developments and discuss their applications to cavity toning and matching problems

  18. Droplet Measurement below Single-Layer Grid Fill

    Directory of Open Access Journals (Sweden)

    Vitkovic Pavol

    2016-01-01

    Full Text Available The main part of the heat transfer in a cooling tower is in a fill zone. This one is consist of a cooling fill. For the cooling tower is used a film fill or grid fill or splash fill in the generally. The grid fill has lower heat transfer performance like film fill usually. But their advantage is high resistance to blockage of the fill. The grid fill is consisted with independent layers made from plastic usually. The layers consist of several bars connected to the different shapes. For experiment was used the rhombus shape. The drops diameter was measured above and below the Grid fill.

  19. Micro-Cavity Fluidic Dye Laser

    DEFF Research Database (Denmark)

    Helbo, Bjarne; Kristensen, Anders; Menon, Aric Kumaran

    2003-01-01

    We have successfully designed, fabricated and characterized a micro-cavity fluidic dye laser with metallic mirrors, which can be integrated with polymer based lab-on-a-chip microsystems without further processing steps. A simple rate-equation model is used to predict the average pumping power...... threshold for lasing as function of cavity-mirror reflectance, laser dye concentration and cavity length. The laser device is characterized using the laser dye Rhodamine 6G dissolved in ethanol. Lasing is observed, and the influence of dye concentration is investigated....

  20. Hydrodynamic Drag on Streamlined Projectiles and Cavities

    KAUST Repository

    Jetly, Aditya

    2016-04-19

    The air cavity formation resulting from the water-entry of solid objects has been the subject of extensive research due to its application in various fields such as biology, marine vehicles, sports and oil and gas industries. Recently we demonstrated that at certain conditions following the closing of the air cavity formed by the initial impact of a superhydrophobic sphere on a free water surface a stable streamlined shape air cavity can remain attached to the sphere. The formation of superhydrophobic sphere and attached air cavity reaches a steady state during the free fall. In this thesis we further explore this novel phenomenon to quantify the drag on streamlined shape cavities. The drag on the sphere-cavity formation is then compared with the drag on solid projectile which were designed to have self-similar shape to that of the cavity. The solid projectiles of adjustable weight were produced using 3D printing technique. In a set of experiments on the free fall of projectile we determined the variation of projectiles drag coefficient as a function of the projectiles length to diameter ratio and the projectiles specific weight, covering a range of intermediate Reynolds number, Re ~ 104 – 105 which are characteristic for our streamlined cavity experiments. Parallel free fall experiment with sphere attached streamlined air cavity and projectile of the same shape and effective weight clearly demonstrated the drag reduction effect due to the stress-free boundary condition at cavity liquid interface. The streamlined cavity experiments can be used as the upper bound estimate of the drag reduction by air layers naturally sustained on superhydrophobic surfaces in contact with water. In the final part of the thesis we design an experiment to test the drag reduction capacity of robust superhydrophobic coatings deposited on the surface of various model vessels.

  1. The Versatile Magic Square.

    Science.gov (United States)

    Watson, Gale A.

    2003-01-01

    Demonstrates the transformations that are possible to construct a variety of magic squares, including modifications to challenge students from elementary grades through algebra. Presents an example of using magic squares with students who have special needs. (YDS)

  2. Investigation of superconducting niobium 1170 MHz cavities

    International Nuclear Information System (INIS)

    Anashin, V.V.; Bibko, S.I.; Fadeyev, E.I.

    1988-01-01

    The design, fabrication and experiments with superconducting L-band single cell cavities are described. These cavities model a cell of an accelerating RF structure. The cavities have been fabricated from technical grade and higher purity grade sheet niobium using deep-drawing, electron beam welding and chemical polishing. They have spherical geometry and are excited in the TM 010 mode. A computerized set-up was used for cavity tests. Qo=1.5 x 10 9 and E acc = 4.3 MV/m were obtained in the cavity made of higher purity grade niobium. 6 references, 8 figures, 3 tables

  3. [Investigation of a new highly porous hydroxyapatite matrix for obliterating open mastoid cavities - application in guinea pigs bulla].

    Science.gov (United States)

    Punke, C; Zehlicke, T; Boltze, C; Pau, H W

    2009-04-01

    Many different techniques for obliterating open mastoid cavity have been described. The results after the application of alloplastic materials like Hydroxyapatite and Tricalciumphosphate were poor due to long-lasting resorption. Extrusion of those materials has been described. We investigated the applicability of a new high-porosity ceramic for obliterating large open mastoid cavities and tested it in an animal model (bulla of guinea pig). A highly porous matrix (NanoBone) bone-inductor fabricated in a sol-gel-technique was administered unilaterally into the opened bullae of 30 guinea pigs. In each animal the opposite bulla was filled with Bio-Oss, a bone substitute consisting of a portion of mineral bovine bone. Histological evaluations were performed 1, 2, 3, 4, 5 and 12 weeks after the implantation. After the initial phase with an inflammatory reaction creating a loose granulation tissue, we observed the formation of trabeculare bone within the fourth week in both groups. From the fifth week on we found osteoclasts on the surface of NanoBone and Bio-Oss with consecutive degradation of both materials. In our animal model study we found beneficial properties of the used bone-inductors NanoBone and Bio-Oss for obliterating open mastoid cavities.

  4. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: An ex vivo evaluation

    Directory of Open Access Journals (Sweden)

    Sreegowri

    2013-01-01

    Full Text Available Aim: The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA mixed with distilled water and 0.12% chlorhexidine (CHX gluconate when used as a root-end filling material using the dye-penetration technique. Materials and Methods: A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Results : No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. Conclusion : CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  5. Fabrication of elliptical SRF cavities

    Science.gov (United States)

    Singer, W.

    2017-03-01

    The technological and metallurgical requirements of material for high-gradient superconducting cavities are described. High-purity niobium, as the preferred metal for the fabrication of superconducting accelerating cavities, should meet exact specifications. The content of interstitial impurities such as oxygen, nitrogen, and carbon must be below 10 μg g-1. The hydrogen content should be kept below 2 μg g-1 to prevent degradation of the quality factor (Q-value) under certain cool-down conditions. The material should be free of flaws (foreign material inclusions or cracks and laminations) that can initiate a thermal breakdown. Traditional and alternative cavity mechanical fabrication methods are reviewed. Conventionally, niobium cavities are fabricated from sheet niobium by the formation of half-cells by deep drawing, followed by trim machining and electron beam welding. The welding of half-cells is a delicate procedure, requiring intermediate cleaning steps and a careful choice of weld parameters to achieve full penetration of the joints. A challenge for a welded construction is the tight mechanical and electrical tolerances. These can be maintained by a combination of mechanical and radio-frequency measurements on half-cells and by careful tracking of weld shrinkage. The main aspects of quality assurance and quality management are mentioned. The experiences of 800 cavities produced for the European XFEL are presented. Another cavity fabrication approach is slicing discs from the ingot and producing cavities by deep drawing and electron beam welding. Accelerating gradients at the level of 35-45 MV m-1 can be achieved by applying electrochemical polishing treatment. The single-crystal option (grain boundary free) is discussed. It seems that in this case, high performance can be achieved by a simplified treatment procedure. Fabrication of the elliptical resonators from a seamless pipe as an alternative is briefly described. This technology has yielded good

  6. Hydroforming of superconducting TESLA cavities

    International Nuclear Information System (INIS)

    Singer, W.; Kaiser, H.; Singer, X.

    2003-01-01

    Seamless fabrication of single-cell and multi-cell TESLA shape cavities by hydroforming has been developed at DESY. The forming takes place by expanding the seamless tube with internal water pressure while simultaneously swaging it axially. Tube radius and axial displacement are being computer controlled in accordance with results of FEM simulations and the experimentally obtained strain-stress curve of tube material. Several Nb single cell cavities have been produced. A first bulk Nb double cell cavity has been fabricated. The Nb seamless tubes have been produced by spinning and deep drawing. Surface treatment such as buffered chemical polishing, (BCP), electropolishing (EP), high pressure ultra pure water rinsing (HPR), annealing at 800degC and baking at ca. 150degC have been applied. The best single cell bulk Nb cavity has reached an accelerating gradient of Eacc > 42 MV/m after ca. 250 μm BCP and 100 μm EP. Several bimetallic NbCu single cell cavities of TESLA shape have been fabricated. The seamless tubes have been produced by explosive bonding and subsequent flow forming. The thicknesses of Nb and Cu layers in the tube wall are about 1 mm and 3 mm respectively. The RF performance of NbCu clad cavities is similar to that of bulk Nb cavities. The highest accelerating gradient achieved was 40 MV/m after ca. 180 μm BCP, annealing at 800degC and baking at 140degC for 30 hours. The degradation of the quality factor Qo after repeated quenching is moderate, after ca. 150 quenches it reaches the saturation point of Qo=1.4x10 10 at low field. This indicates that on the basis of RF performance and material costs the combination of hydroforming with tube cladding is a very promising option. (author)

  7. Merging physical parameters and laboratory subjective ratings for the soundscape assessment of urban squares.

    Science.gov (United States)

    Brambilla, Giovanni; Maffei, Luigi; Di Gabriele, Maria; Gallo, Veronica

    2013-07-01

    An experimental study was carried out in 20 squares in the center of Rome, covering a wide range of different uses, sonic environments, geometry, and architectural styles. Soundwalks along the perimeter of each square were performed during daylight and weekdays taking binaural and video recordings, as well as spot measurements of illuminance. The cluster analysis performed on the physical parameters, not only acoustic, provided two clusters that are in satisfactory agreement with the "a priori" classification. Applying the principal component analysis (PCA) to five physical parameters, two main components were obtained which might be associated to two environmental features, namely, "chaotic/calm" and "open/enclosed." On the basis of these two features, six squares were selected for the laboratory audio-video tests where 32 subjects took part filling in a questionnaire. The PCA performed on the subjective ratings on the sonic environment showed two main components which might be associated to two emotional meanings, namely, "calmness" and "vibrancy." The linear regression modeling between five objective parameters and the mean value of subjective ratings on chaotic/calm and enclosed/open attributes showed a good correlation. Notwithstanding these interesting results being limited to the specific data set, it is worth pointing out that the complexity of the soundscape quality assessment can be more comprehensively examined merging the field measurements of physical parameters with the subjective ratings provided by field and/or laboratory tests.

  8. Hydroforming of Tesla Cavities at Desy

    International Nuclear Information System (INIS)

    Singer, W.; Kaiser, H.; Singer, X.; Gonin, I.; Zhelezov, I.; Khabibullin, T.; Kneisel, P.; Saito, K.

    2000-01-01

    Since several years the development of seamless niobium cavity fabrication by hydro forming is being pursued at DESY. This technique offers the possibility of lower cost of fabrication and perhaps better rf performance of the cavities because of the elimination of electron-beam welds, which in the standard fabrication technique have sometimes lead to inferior cavity performance due to defects. Several single cell 1300 MHz cavities have been formed from high purity seamless niobium tubes, which are under computer control expanded with internal pressure while simultaneously being swaged axially. The seamless tubes have been made by either back extrusion and flow forming or by spinning or deep drawing. Standard surface treatment techniques such as high temperature post purification, buffered chemical polishing (BCP), electropolishing (EP) and high pressure ultra pure water rinsing (HPR) have been applied to these cavities. The cavities exhibited high Q - values of 2 x 10 10 at 2K and residual resistances as low as 3 n(Omega) after the removal of a surface layer of app. 100 (micro)m by BCP. Surprisingly, even at high gradients up to the maximum measured values of E acc ∼ 33 MV/m the Q-value did not decrease in the absence of field emission as often observed. After electropolishing of additional 100 (micro)m one of the cavities reached an accelerating gradient of E acc (ge) 42 MV/m

  9. Moment-based boundary conditions for lattice Boltzmann simulations of natural convection in cavities

    KAUST Repository

    Allen, Rebecca

    2016-06-29

    We study a multiple relaxation time lattice Boltzmann model for natural convection with moment-based boundary conditions. The unknown primary variables of the algorithm at a boundary are found by imposing conditions directly upon hydrodynamic moments, which are then translated into conditions for the discrete velocity distribution functions. The method is formulated so that it is consistent with the second order implementation of the discrete velocity Boltzmann equations for fluid flow and temperature. Natural convection in square cavities is studied for Rayleigh numbers ranging from 103 to 108. An excellent agreement with benchmark data is observed and the flow fields are shown to converge with second order accuracy. Copyright © 2016 Inderscience Enterprises Ltd.

  10. Harnessing the mode mixing in optical fiber-tip cavities

    International Nuclear Information System (INIS)

    Podoliak, Nina; Horak, Peter; Takahashi, Hiroki; Keller, Matthias

    2017-01-01

    We present a systematic numerical study of Fabry–Pérot optical cavities with Gaussian-shape mirrors formed between tips of optical fibers. Such cavities can be fabricated by laser machining of fiber tips and are promising systems for achieving strong coupling between atomic particles and an optical field as required for quantum information applications. Using a mode mixing matrix method, we analyze the cavity optical eigenmodes and corresponding losses depending on a range of cavity-shape parameters, such as mirror radius of curvature, indentation depth and cavity length. The Gaussian shape of the mirrors causes mixing of optical modes in the cavity. We investigate the effect of the mode mixing on the coherent atom-cavity coupling as well as the mode matching between the cavity and a single-mode optical fiber. While the mode mixing is associated with increased cavity losses, it can also lead to an enhancement of the local optical field. We demonstrate that around the resonance between the fundamental and 2nd order Laguerre–Gaussian modes of the cavity it is possible to obtain 50% enhancement of the atom-cavity coupling at the cavity center while still maintaining low cavity losses and high cavity-fiber optical coupling. (paper)

  11. Evaluation of technical quality and periapical health of root-filled teeth by using cone-beam CT

    Directory of Open Access Journals (Sweden)

    Bilge Gülsüm NUR

    2014-12-01

    Full Text Available Objective This study aimed to assess the quality of root fillings, coronal restorations, complications of all root-filled teeth and their association with apical periodontitis (AP detected by cone-beam computed tomography (CBCT images from an adult Turkish subpopulation. Material and Methods The sample for this study consisted of 242 patients (aging from 15 to 72 years with 522 endodontically treated teeth that were assessed for technical quality of the root canal filling and periapical status of the teeth. Additionally, the apical status of each root-filled tooth was assessed according to the gender, dental arch, tooth type and age classification, undetected canals, instrument fracture, root fracture, apical resorption, apical lesion, furcation lesion and type and quality of the coronal structure. Statistical analysis was performed using percentages and chi-square test. Results The success rate of the root canal treatment was of 54.4%. The success rates of adequate and inadequate root canal treatment were not significantly different (p>0.05. Apical periodontitis was found in 228 (45.6% teeth treated for root canals. Higher prevalence of AP was found in patients aging from 20 to 29 years [64 (27% teeth] and in anterior (canines and incisors teeth [97 (41% teeth]. Conclusions The technical quality of root canal filling performed by dental practitioners in a Turkish subpopulation was consistent with a high prevalence of AP. The probable reasons for this failure are multifactorial, and there may be a need for improved undergraduate education and postgraduate courses to improve the clinical skills of dental practitioners in endodontics.

  12. Coupling of an overdriven cavity

    International Nuclear Information System (INIS)

    Garbin, H.D.

    1993-01-01

    It is well known that when a nuclear test is conducted in a sufficiently large cavity, the resulting seismic signal is sharply reduced when compared to a normal tamped event. Cavity explosions are of interest in the seismic verification community because of this possibility of reducing the seismic energy generated which can lower signal amplitudes and make detection difficult. Reduced amplitudes would also lower seismic yield estimates which has implications in a Threshold Test Ban Treaty (TTBT). In the past several years, there have been a number of nuclear tests at NTS (Nevada Test Site) inside hemispherical cavities. Two such tests were MILL YARD and MISTY ECHO which had instrumentation at the surface and in the free-field. These two tests differ in one important aspect. MILL YARD was completely decoupled i.e., the cavity wall behaved in an elastic manner. It was estimated that MILL YARD's ground motion was reduced by a factor of at least 70. In contrast, MISTY ECHO was detonated in a hemispherical cavity with the same dimensions as MILL YARD, but with a much larger device yield. This caused an inelastic behavior on the wall and the explosion was not fully decoupled

  13. Hydrogeology of Valley-Fill Aquifers and Adjacent Areas in Eastern Chemung County, New York

    Science.gov (United States)

    Heisig, Paul M.

    2015-10-19

    The extent, hydrogeologic framework, and potential well yields of valley-fill aquifers within a 151-square-mile area of eastern Chemung County, New York, were investigated, and the upland distribution of till thickness over bedrock was characterized. The hydrogeologic framework of these valleyfill aquifers was interpreted from multiple sources of surficial and subsurface data and an interpretation of the origin of the glacial deposits, particularly during retreat of glacial ice from the region. Potential yields of screened wells are based on the hydrogeologic framework interpretation and existing well-yield data, most of which are from wells finished with open-ended well casing.

  14. A split-cavity design for the incorporation of a DC bias in a 3D microwave cavity

    NARCIS (Netherlands)

    Cohen, M.A.; Yuan, M.; de Jong, B.W.A.; Beukers, Ewout; Bosman, S.J.; Steele, G.A.

    2017-01-01

    We report on a technique for applying a DC bias in a 3D microwave cavity. We achieve this by isolating the two halves of the cavity with a dielectric and directly using them as DC electrodes. As a proof of concept, we embed a variable capacitance diode in the cavity and tune the resonant

  15. Niobium LEP 2 accelerating cavities

    CERN Multimedia

    An accelerating cavity from LEP. This could be cut open to show the layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities were used in an upgrade of the LEP accelerator to double the energy of the particle beams.

  16. THE INFLUENCE OF OPEN SPACE UTILIZATION ON RESIDENTS’ ATTACHMENT WITH COMMUNITY: A CASE STUDY OF RURAL MARKET SQUARE IN SOUTH-WEST NIGERIA

    Directory of Open Access Journals (Sweden)

    Agboola Oluwagbemiga Paul

    2017-03-01

    Full Text Available Open space such as market square is a communal ground where people carry out their various functional activities. This research work is undertaken in order to fill the knowledge gap in areas of people and place relationship, where improvements are needed to overcome challenges in the provision of facilities, design, and planning. In view of its significance, it becomes imperative to explore the relationship between the utilization of market square and residents’ attachment to the community. Therefore, 382 respondents’ views on market dependence, identity, activities preferences, and attachment to the community were collected through self-administered questionnaires. The findings from Structural Equation Modelling (SEM using AMOS tool version 22 for the tested hypothesized model reveal that residents’ dependence and identity with market square had positive significant impacts on residents’ attachment to the community with standardised path coefficient values of 0.32 and 0.48 respectively. It is therefore suggested that appropriate machinery should be put in place towards improving the quality of the market square to further enhance users’ interaction cum the sustainability of the community in Nigeria.

  17. Prototype superconducting radio-frequency cavity for LEP

    CERN Multimedia

    1985-01-01

    This niobium superconducting cavity was part of the prototype stages for an upgrade to LEP, known as LEP-2. Superconducting cavities would eventually replace the traditional copper cavities and allow beam energies of 100 GeV.

  18. Formation of regolith-collapse sinkholes in southern Illinois: Interpretation and identification of associated buried cavities

    Science.gov (United States)

    Panno, S.V.; Wiebel, C.P.; Heigold, P.C.; Reed, P.C.

    1994-01-01

    Three regolith-collapse sinkholes formed near the Dongola Unit School and the Pentecostal Church in the southern Illinois village of Dongola (Union County) during the spring of 1993. The sinkholes appeared over a three-month period that coincided with development of a new municipal well. The new well was drilled through clay-rich, valley-fill sediment into karstified limestone bedrock. The piezometric surface of the limestone aquifer is above land surface, indicating the presence of an upward hydraulic gradient in the valley and that the valley fill is acting as a confining unit. Pumping during development of the well lowered the piezometric surface of the limestone aquifer to an elevation below the base of the valley fill. It is hypothesized that drainage of water from the sediments, the resulting loss of hydrostatic pressure and buoyant force in overlying sediments, increased intergranular pressure, and the initiation of groundwater flow toward the well resulted in rapid sediment transport, subsurface erosion, and collapse of the valley-fill sediment. The sinkholes follow an approximately east-west alignment, which is consistent with one of the two dominant alignments of passages of nearby joint-controlled caves. A constant electrode-separation resistivity survey of the school playground was conducted to locate areas that might contain incipient sinkholes. The survey revealed a positive resistivity anomaly trending N75E in the southern part of the study area. The anomaly is linear, between 5 and 10 m wide, and its trend either intersects or is immediately adjacent to the three sinkholes. The anomaly is interpreted to be a series of pumping-induced cavities in the valley-fill sediments that formed over a preexisting crevice in the karstified bedrock limestone. ?? 1994 Springer-Verlag.

  19. Diagram of a LEP superconducting cavity

    CERN Multimedia

    1991-01-01

    This diagram gives a schematic representation of the superconducting radio-frequency cavities at LEP. Liquid helium is used to cool the cavity to 4.5 degrees above absolute zero so that very high electric fields can be produced, increasing the operating energy of the accelerator. Superconducting cavities were used only in the LEP-2 phase of the accelerator, from 1996 to 2000.

  20. Computer codes for RF cavity design

    International Nuclear Information System (INIS)

    Ko, K.

    1992-01-01

    In RF cavity design, numerical modeling is assuming an increasingly important role with the help of sophisticated computer codes and powerful yet affordable computers. A description of the cavity codes in use in the accelerator community has been given previously. The present paper will address the latest developments and discuss their applications to cavity tuning and matching problems. (Author) 8 refs., 10 figs

  1. Cavity QED experiments with ion Coulomb crystals

    DEFF Research Database (Denmark)

    Herskind, Peter Fønss; Dantan, Aurélien; Marler, Joan

    2009-01-01

    Cavity QED experimental results demonstrating collective strong coupling between ensembles of atomic ions cooled into Coulomb crystals and optical cavity fields have been achieved. Collective Zeeman coherence times of milliseconds have furthermore been obtained.......Cavity QED experimental results demonstrating collective strong coupling between ensembles of atomic ions cooled into Coulomb crystals and optical cavity fields have been achieved. Collective Zeeman coherence times of milliseconds have furthermore been obtained....

  2. Influence from cavity decay on geometric quantum computation in the large-detuning cavity QED model

    International Nuclear Information System (INIS)

    Chen Changyong; Zhang Xiaolong; Deng Zhijiao; Gao Kelin; Feng Mang

    2006-01-01

    We introduce a general displacement operator to investigate the unconventional geometric quantum computation with dissipation under the model of many identical three-level atoms in a cavity, driven by a classical field. Our concrete calculation is made for the case of two atoms, based on a previous scheme [S.-B. Zheng, Phys. Rev. A 70, 052320 (2004)] for the large-detuning interaction of the atoms with the cavity mode. The analytical results we present will be helpful for experimental realization of geometric quantum computation in real cavities

  3. Analogy of electromagnetically induced transparency in plasmonic nanodisk with a square ring resonator

    International Nuclear Information System (INIS)

    Li, Xianping; Wei, Zhongchao; Liu, Yuebo; Zhong, Nianfa; Tan, Xiaopei; Shi, Songsong; Liu, Hongzhan; Liang, Ruisheng

    2016-01-01

    We have demonstrated the analogy of electromagnetically induced transparency in plasmonic nanodisk with a square ring resonator. A reasonable analysis of the transmission feature based on the temporal coupled-mode theory is given and shows good agreement with the Finit-Difference Time-Domain simulation. The transparency window can be easily tuned by changing the geometrical parameters and the insulator filled in the resonator. The transmission of the resonator system is close to 80% and the full width at half maximum is less than 46 nm. The sensitivity of the structure is about 812 nm/RIU. These characteristics make the new system with potential to apply for optical storage, ultrafast plasmonic switch and slow-light devices.

  4. Analogy of electromagnetically induced transparency in plasmonic nanodisk with a square ring resonator

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xianping; Wei, Zhongchao, E-mail: wzc@scnu.edu.cn; Liu, Yuebo; Zhong, Nianfa; Tan, Xiaopei; Shi, Songsong; Liu, Hongzhan; Liang, Ruisheng

    2016-01-08

    We have demonstrated the analogy of electromagnetically induced transparency in plasmonic nanodisk with a square ring resonator. A reasonable analysis of the transmission feature based on the temporal coupled-mode theory is given and shows good agreement with the Finit-Difference Time-Domain simulation. The transparency window can be easily tuned by changing the geometrical parameters and the insulator filled in the resonator. The transmission of the resonator system is close to 80% and the full width at half maximum is less than 46 nm. The sensitivity of the structure is about 812 nm/RIU. These characteristics make the new system with potential to apply for optical storage, ultrafast plasmonic switch and slow-light devices.

  5. Influence of the Periodicity of Sinusoidal Boundary Condition on the Unsteady Mixed Convection within a Square Enclosure Using an Ag–Water Nanofluid

    Directory of Open Access Journals (Sweden)

    Azharul Karim

    2017-12-01

    Full Text Available A numerical study of the unsteady mixed convection heat transfer characteristics of an Ag–water nanofluid confined within a square shape lid-driven cavity has been carried out. The Galerkin weighted residual of the finite element method has been employed to investigate the effects of the periodicity of sinusoidal boundary condition for a wide range of Grashof numbers (Gr (105 to 107 with the parametric variation of sinusoidal even and odd frequency, N, from 1 to 6 at different instants (for τ = 0.1 and 1. It has been observed that both the Grashof number and the sinusoidal even and odd frequency have a significant influence on the streamlines and isotherms inside the cavity. The heat transfer rate enhanced by 90% from the heated surface as the Grashof number (Gr increased from 105 to 107 at sinusoidal frequency N = 1 and τ = 1.

  6. Numerical investigation of double diffusive buoyancy forces induced natural convection in a cavity partially heated and cooled from sidewalls

    Directory of Open Access Journals (Sweden)

    Rasoul Nikbakhti

    2016-03-01

    Full Text Available This paper deals with a numerical investigation of double-diffusive natural convective heat and mass transfer in a cavity filled with Newtonian fluid. The active parts of two vertical walls of the cavity are maintained at fixed but different temperatures and concentrations, while the other two walls, as well as inactive areas of the sidewalls, are considered to be adiabatic and impermeable to mass transfer. The length of the thermally active part equals half of the height. The non-dimensional forms of governing transport equations that describe double-diffusive natural convection for two-dimensional incompressible flow are functions of temperature or energy, concentration, vorticity, and stream-function. The coupled differential equations are discretized via FDM (Finite Difference Method. The Successive-Over-Relaxation (SOR method is used in the solution of the stream function equation. The analysis has been done for an enclosure with different aspect ratios ranging from 0.5 to 11 for three different combinations of partially active sections. The results are presented graphically in terms of streamlines, isotherms and isoconcentrations. In addition, the heat and mass transfer rate in the cavity is measured in terms of the average Nusselt and Sherwood numbers for various parameters including thermal Grashof number, Lewis number, buoyancy ratio and aspect ratio. It is revealed that the placement order of partially thermally active walls and the buoyancy ratio influence significantly the flow pattern and the corresponding heat and mass transfer performance in the cavity.

  7. Development of the L-band superconducting cavity system

    Energy Technology Data Exchange (ETDEWEB)

    Ota, T.; Kakutani, N.; Sukenobu, S. [Toshiba Corp., Yokohama, Kanagawa (JP)] [and others

    2000-02-01

    R and D activities on superconducting cavities in 1998 at TOSHIBA are presented. An L-band single-cell niobium cavity with four ports on the beam pipes was fabricated in our company and tested at KEK. The cryostat and refrigerator system for the cavity were designed and fabricated. The cryostat installed the cavity was tested in low temperature. R and D of hydroforming to fabricate seamless cavities is also presented. (author)

  8. Development of the L-band superconducting cavity system

    International Nuclear Information System (INIS)

    Ota, T.; Kakutani, N.; Sukenobu, S.

    2000-01-01

    R and D activities on superconducting cavities in 1998 at TOSHIBA are presented. An L-band single-cell niobium cavity with four ports on the beam pipes was fabricated in our company and tested at KEK. The cryostat and refrigerator system for the cavity were designed and fabricated. The cryostat installed the cavity was tested in low temperature. R and D of hydroforming to fabricate seamless cavities is also presented. (author)

  9. The CEBAF separator cavity resonance control system

    International Nuclear Information System (INIS)

    M. Wissmann; C. Hovater; A. Guerra; T. Plawski

    2005-01-01

    The CEBAF energy upgrade will increase the maximum beam energy from 6 GeV to 12 GeV available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three halls. The resulting increase in RF separator cavity gradient and subsequent increase in RF power needed for these higher energies will require the cavities to have active resonance control. Currently, at the present 4 to 6 GeV energies, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW) which is maintained at a constant temperature of 95 Fahrenheit. This approach is no longer feasible and an active resonance control system that controls both water temperature and flow has been designed and built. The system uses a commercial PLC with embedded PID controls to regulate water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately, closed loop control will be maintained by monitoring each cavity's reflected power. This paper describes this system

  10. Beam tests and operation of superconducting cavities

    International Nuclear Information System (INIS)

    Akai, Kazunori

    1990-01-01

    Beam tests and operation of superconducting cavities conducted since the third workshop on RF superconductivity (Argonne, Sep. 1987) are reported in this paper. The paper is concerned particularly with electron machines. Storage and acceleration of the beam are discussed, focusing on the CERN test in SPS, the DESY test in PETRA, the superconducting injector at Darmstadt, and the KEK beam tests in T-AR. Then, long-term performance of the cavity in the ring is discussed focusing on Eacc (max) and O-value, environmental conditions, and operational experience in T-MR. RF controllability is addressed, centering on the Robinson stability, cavity tuning loop, quench detection and interlocks, recovery procedure, field calibration, and phase adjustment. Higher order modes are also discussed. Superconducting cavities have been operated successfully in accelerators. It has been confirmed that the superconducting cavities can be used stably for experimental use. For more than 5000 hours the cavities have indicated no essential degradation of the cavity performance. The study of long-term performance should be continued in longer range of period. (N.K.)

  11. Turbulent flow in a partially filled pipe

    Science.gov (United States)

    Ng, Henry; Cregan, Hope; Dodds, Jonathan; Poole, Robert; Dennis, David

    2017-11-01

    Turbulent flow in a pressure driven pipe running partially full has been investigated using high-speed 2D-3C Stereoscopic Particle Imaging Velocimetry. With the field-of-view spanning the entire pipe cross section we are able to reconstruct the full three dimensional quasi-instantaneous flow field by invoking Taylor's hypothesis. The measurements were carried out over a range of flow depths at a constant Reynolds number based on hydraulic diameter and bulk velocity of Re = 32 , 000 . In agreement with previous studies, the ``velocity dip'' phenomenon, whereby the location of the maximum streamwise velocity occurs below the free surface was observed. A mean flow secondary current is observed near the free surface with each of the counter-rotating rollers filling the half-width of the pipe. Unlike fully turbulent flow in a rectangular open channel or pressurized square duct flow where the secondary flow cells appear in pairs about a corner bisector, the mean secondary motion observed here manifests only as a single pair of vortices mirrored about the pipe vertical centreline.

  12. Eye rotation induced dynamics of a Newtonian fluid within the vitreous cavity: the effect of the chamber shape

    International Nuclear Information System (INIS)

    Stocchino, Alessandro; Repetto, Rodolfo; Cafferata, Chiara

    2007-01-01

    The dynamics of the vitreous body induced by eye rotations is studied experimentally. In particular, we consider the case in which the vitreous cavity is filled by a Newtonian fluid, either because the vitreous is liquefied or because it has been replaced, after vitrectomy, by a viscous fluid. We employ a rigid Perspex container which models, in a magnified scale, the vitreous cavity of the human eye. The shape of the cavity closely resembles that of the real vitreous chamber; in particular, the anterior part of the container is concave in order to model the presence of the eye lens. The container is filled with glycerol and is mounted on the shaft of a computer-controlled motor which rotates according to a periodic time law. PIV (particle image velocimetry) measurements are taken on the equatorial plane orthogonal to the axis of rotation. The experimental measurements show that the velocity field is strongly influenced by the deformed geometry of the domain. In particular, the formation of a vortex in the vicinity of the lens, which migrates in time towards the core of the domain, is invariably observed. The vortex path is tracked in time by means of a vortex identification technique and it is found that it is significantly influenced by the Womersley number of the flow. Particle trajectories are computed from the PIV measurements. Particles initially located at different positions on the equatorial horizontal plane (perpendicular to the axis of rotation) tend to concentrate in narrow regions adjacent to the lens, thus suggesting the existence, in such regions, of a vertical fluid ejection. Such a strong flow three-dimensionality, which is essentially induced by the irregular shape of the domain, may play a significant role in the mixing processes taking place inside the eye globe. The tangential stresses acting on the rigid boundary of the domain are also computed from the experimental measurements showing that regions subject to particularly intense stresses

  13. Elliptical superconducting RF cavities for FRIB energy upgrade

    Science.gov (United States)

    Ostroumov, P. N.; Contreras, C.; Plastun, A. S.; Rathke, J.; Schultheiss, T.; Taylor, A.; Wei, J.; Xu, M.; Xu, T.; Zhao, Q.; Gonin, I. V.; Khabiboulline, T.; Pischalnikov, Y.; Yakovlev, V. P.

    2018-04-01

    The multi-physics design of a five cell, βG = 0 . 61, 644 MHz superconducting elliptical cavity being developed for an energy upgrade in the Facility for Rare Isotope Beams (FRIB) is presented. The FRIB energy upgrade from 200 MeV/u to 400 MeV/u for heaviest uranium ions will increase the intensities of rare isotope beams by nearly an order of magnitude. After studying three different frequencies, 1288 MHz, 805 MHz, and 644 MHz, the 644 MHz cavity was shown to provide the highest energy gain per cavity for both uranium and protons. The FRIB upgrade will include 11 cryomodules containing 5 cavities each and installed in 80-meter available space in the tunnel. The cavity development included extensive multi-physics optimization, mechanical and engineering analysis. The development of a niobium cavity is complete and two cavities are being fabricated in industry. The detailed design of the cavity sub-systems such as fundamental power coupler and dynamic tuner are currently being pursued. In the overall design of the cavity and its sub-systems we extensively applied experience gained during the development of 650 MHz low-beta cavities at Fermi National Accelerator Laboratory (FNAL) for the Proton Improvement Plan (PIP) II.

  14. Applications of square-related theorems

    Science.gov (United States)

    Srinivasan, V. K.

    2014-04-01

    The square centre of a given square is the point of intersection of its two diagonals. When two squares of different side lengths share the same square centre, there are in general four diagonals that go through the same square centre. The Two Squares Theorem developed in this paper summarizes some nice theoretical conclusions that can be obtained when two squares of different side lengths share the same square centre. These results provide the theoretical basis for two of the constructions given in the book of H.S. Hall and F.H. Stevens , 'A Shorter School Geometry, Part 1, Metric Edition'. In page 134 of this book, the authors present, in exercise 4, a practical construction which leads to a verification of the Pythagorean theorem. Subsequently in Theorems 29 and 30, the authors present the standard proofs of the Pythagorean theorem and its converse. In page 140, the authors present, in exercise 15, what amounts to a geometric construction, whose verification involves a simple algebraic identity. Both the constructions are of great importance and can be replicated by using the standard equipment provided in a 'geometry toolbox' carried by students in high schools. The author hopes that the results proved in this paper, in conjunction with the two constructions from the above-mentioned book, would provide high school students an appreciation of the celebrated theorem of Pythagoras. The diagrams that accompany this document are based on the free software GeoGebra. The author formally acknowledges his indebtedness to the creators of this free software at the end of this document.

  15. Numerical and Experimental Analysis on the Cavity Formation and Shrinkage for Investment Cast Alloy 738 4 mm-Thick Rectangular Tube

    International Nuclear Information System (INIS)

    Park, Myeong-Il; Choi, Yoon Suk; Yoo, Jae-Hyun; Park, Sang-Hu; Kim, Kyeong-Min; Lee, Yeong-Chul; Lee, Jung-Seok; Lee, Jae-Hyun

    2017-01-01

    Investment casting for the thin (4 mm thick) rectangular tube (40 mm wide, 80 mm high and 200 mm long) was carried out numerically and experimentally for Alloy 738, which is a precipitation-hardened Ni-base superalloy. Two types of rectangular tubes, one with a regular array (10 mm by 10 mm square array) of protruded rods (3 mm in diameter and 3mm in height) embedded on the outer surface and the other with just smooth surface, were investment-cast at the same time through the side feeding mold design. The investment casting simulation predicted the presence of cavities, particularly in the area away from the gate for both types of rectangular tubes. In particular, for the rectangular tube with embedded protruded rods cavities were found mainly in the areas between the protruded rods. This simulation result was qualitatively consistent with the experimental observation from the X-ray analysis. Also, both prediction and experiment showed that the dimensional shrinkage (particularly in the longitudinal direction) of the investment-cast rectangular tube is reduced by having protruded rods embedded on the outer surface. Additional numerical attempts were made to check how the amount of cavities and dimensional shrinkage change by varying the preheating temperature and the thickness of the mold. The results predicted that the amount of cavities and the dimensional shrinkage are significantly reduced by increasing the preheating temperature of the mold by 200 ℃. However, an increase in mold thickness from 10 mm to 12 mm showed almost no difference in cavity population and a slight decrease in dimensional shrinkage.

  16. Numerical and Experimental Analysis on the Cavity Formation and Shrinkage for Investment Cast Alloy 738 4 mm-Thick Rectangular Tube

    Energy Technology Data Exchange (ETDEWEB)

    Park, Myeong-Il; Choi, Yoon Suk; Yoo, Jae-Hyun; Park, Sang-Hu [Pusan National University, Busan (Korea, Republic of); Kim, Kyeong-Min; Lee, Yeong-Chul [Sung Il Turbine Co., Ltd., Busan (Korea, Republic of); Lee, Jung-Seok; Lee, Jae-Hyun [Changwon National University, Changwon (Korea, Republic of)

    2017-02-15

    Investment casting for the thin (4 mm thick) rectangular tube (40 mm wide, 80 mm high and 200 mm long) was carried out numerically and experimentally for Alloy 738, which is a precipitation-hardened Ni-base superalloy. Two types of rectangular tubes, one with a regular array (10 mm by 10 mm square array) of protruded rods (3 mm in diameter and 3mm in height) embedded on the outer surface and the other with just smooth surface, were investment-cast at the same time through the side feeding mold design. The investment casting simulation predicted the presence of cavities, particularly in the area away from the gate for both types of rectangular tubes. In particular, for the rectangular tube with embedded protruded rods cavities were found mainly in the areas between the protruded rods. This simulation result was qualitatively consistent with the experimental observation from the X-ray analysis. Also, both prediction and experiment showed that the dimensional shrinkage (particularly in the longitudinal direction) of the investment-cast rectangular tube is reduced by having protruded rods embedded on the outer surface. Additional numerical attempts were made to check how the amount of cavities and dimensional shrinkage change by varying the preheating temperature and the thickness of the mold. The results predicted that the amount of cavities and the dimensional shrinkage are significantly reduced by increasing the preheating temperature of the mold by 200 ℃. However, an increase in mold thickness from 10 mm to 12 mm showed almost no difference in cavity population and a slight decrease in dimensional shrinkage.

  17. Single and Coupled Nanobeam Cavities

    DEFF Research Database (Denmark)

    Ivinskaya, Aliaksandra; Lavrinenko, Andrei; Shyroki, Dzmitry M.

    2013-01-01

    for analysis and design of photonic crystal devices, such as 2D ring resonators for filters, single and coupled nanobeam cavities, birefringence in photonic crystal cavities, threshold analysis in photonic crystal lasers, gap solitons in photonic crystals, novel photonic atolls, dynamic characteristics...

  18. Microhardness of bulk-fill composite materials

    OpenAIRE

    Kelić, Katarina; Matić, Sanja; Marović, Danijela; Klarić, Eva; Tarle, Zrinka

    2016-01-01

    The aim of the study was to determine microhardness of high- and low-viscosity bulk-fill composite resins and compare it with conventional composite materials. Four materials of high-viscosity were tested, including three bulk-fills: QuiXfi l (QF), x-tra fil (XTF) and Tetric EvoCeram Bulk Fill (TEBCF), while nanohybrid composite GrandioSO (GSO) served as control. The other four were low-viscosity composites, three bulk-fill materials: Smart Dentin Replacement (SDR), Venus Bulk Fill (VBF) and ...

  19. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  20. Q0 Degradation of LANL 700-MHZ β = 0.64 Elliptical Cavities and ANL 340 MHZ Spoke Cavities

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi; Chan, Kwok-Chi D.; Edwards, Randall L.; Gentzlinger, Robert C.; Kelley, John Patrick; Krawczyk, Frank L.; Madrid, Michael A.; Montoya, Debbie I.; Schrage, Dale L.; Shapiro, Alan H.

    2002-01-01

    The quality factor (Q 0 ) of most of the six LANL β = 0.64 700-MHz 5-cell elliptical cavities starts to drop at E acc = 8-10 MV/m, which may be related to multipacting. Residual resistances of these cavities were measured to be 5.0-7.6 n(Omega). The sensitivity of surface resistance to the external magnetic field was measured to be 0.22 n(Omega)/mG. Q disease tests have shown no significant Q 0 degradation for both elliptical cavities and a spoke cavity with our 100 (micro)m BCP.

  1. 1.3 GHz superconducting RF cavity program at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Ginsburg, C.M.; Arkan, T.; Barbanotti, S.; Carter, H.; Champion, M.; Cooley, L.; Cooper, C.; Foley, M.; Ge, M.; Grimm, C.; Harms, E.; /Fermilab

    2011-03-01

    At Fermilab, 9-cell 1.3 GHz superconducting RF (SRF) cavities are prepared, qualified, and assembled into cryomodules (CMs) for Project X, an International Linear Collider (ILC), or other future projects. The 1.3 GHz SRF cavity program includes targeted R&D on 1-cell 1.3 GHz cavities for cavity performance improvement. Production cavity qualification includes cavity inspection, surface processing, clean assembly, and one or more cryogenic low-power CW qualification tests which typically include performance diagnostics. Qualified cavities are welded into helium vessels and are cryogenically tested with pulsed high-power. Well performing cavities are assembled into cryomodules for pulsed high-power testing in a cryomodule test facility, and possible installation into a beamline. The overall goals of the 1.3 GHz SRF cavity program, supporting facilities, and accomplishments are described.

  2. Effect of irradiation mode and filling technique on resin/dentin bonding strength in class I cavities Efeito do modo de ativação e da técnica restauradora na resistência de união entre compósito e dentina em cavidades classe I

    Directory of Open Access Journals (Sweden)

    Alex José Souza dos Santos

    2004-09-01

    Full Text Available Factors such as light-curing mode, filling technique and cavity configuration may affect the bonding strength to dentin. This study evaluated the effect of irradiation mode and filling technique on resin/dentin bonding strength on the buccal wall of class I cavities in human teeth. Occlusal enamel was removed to expose a flat dentin surface. Occlusal cavities (4 x 3 x 3 mm were prepared in dentin. The adhesive Single Bond was applied according to the manufacturer's instructions and TPH Spectrum composite resin was placed using the following: oblique incremental, horizontal incremental or bulk filling techniques. The composite resin was light-cured either by continuous (600 mW/cm² for 40 s or Soft-Start (250 mW/cm² for 10 s + 600 mW/cm² for 30 s modes. Specimens of the control group were obtained by bonding the material to the flat exposed buccal wall of the cavity (C-factor = 1. The teeth were stored in water at 37ºC for 24 h and prepared for microtensile testing. Bonded beams of approximately 0.8 mm² were obtained from the buccal wall and tested with a tension of 0.5 mm/min. Results were analyzed by two-way ANOVA, Tukey's test and Dunnett's test (alpha = 0.05. Incremental placement techniques with both irradiation modes produced higher bonding strength values than the bulk technique (p Fatores como o modo de ativação, a técnica restauradora e a configuração cavitária podem afetar a resistência adesiva à dentina. Este estudo avaliou os efeitos dos modos de ativação e das técnicas restauradoras na resistência de união compósito/dentina na parede vestibular de restaurações classe I. O esmalte oclusal dos dentes foi removido para expor uma superfície dentinária planificada. Cavidades oclusais (4 x 3 x 3 mm foram preparadas em dentina. O adesivo Single Bond foi aplicado de acordo com as instruções do fabricante, e o compósito TPH Spectrum, inserido através de três diferentes técnicas: oblíqua incremental, horizontal

  3. Photons in a spherical cavity

    International Nuclear Information System (INIS)

    Ionescu-Pallas, N.; Vlad, V.I.

    1999-01-01

    The spectrum of black body radiation at the absolute temperature T, in an ideal spherical cavity of radius R, is studied. The departures from the classical predictions of Planck's theory, due to the discrete energies of the radiation quanta confined inside the cavity, depend on the adiabatic invariant RT and are significant for RT≤ 1 cm K. Special attention was paid to evidence sudden changes in the spectrum intensities, forbidden bands of frequency, as well as major modifications of the total energy for RT≤ 1 cm K. Similar effects were present in case of a cubic cavity too. (authors)

  4. Emulating facial biomechanics using multivariate partial least squares surrogate models.

    Science.gov (United States)

    Wu, Tim; Martens, Harald; Hunter, Peter; Mithraratne, Kumar

    2014-11-01

    A detailed biomechanical model of the human face driven by a network of muscles is a useful tool in relating the muscle activities to facial deformations. However, lengthy computational times often hinder its applications in practical settings. The objective of this study is to replace precise but computationally demanding biomechanical model by a much faster multivariate meta-model (surrogate model), such that a significant speedup (to real-time interactive speed) can be achieved. Using a multilevel fractional factorial design, the parameter space of the biomechanical system was probed from a set of sample points chosen to satisfy maximal rank optimality and volume filling. The input-output relationship at these sampled points was then statistically emulated using linear and nonlinear, cross-validated, partial least squares regression models. It was demonstrated that these surrogate models can mimic facial biomechanics efficiently and reliably in real-time. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Graphs whose complement and square are isomorphic

    DEFF Research Database (Denmark)

    Pedersen, Anders Sune

    2014-01-01

    We study square-complementary graphs, that is, graphs whose complement and square are isomorphic. We prove several necessary conditions for a graph to be square-complementary, describe ways of building new square-complementary graphs from existing ones, construct infinite families of square-compl...

  6. Multi-Mode Cavity Accelerator Structure

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yong [Yale Univ., New Haven, CT (United States); Hirshfield, Jay Leonard [Omega-P R& D, Inc., New Haven, CT (United States)

    2016-11-10

    This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10-7/pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise ΔT. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field Esurmax< 260 MV/m and pulsed surface heating ΔTmax< 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power—as compared with operation at the same acceleration gradient using only the fundamental mode.

  7. Multi-Mode Cavity Accelerator Structure

    International Nuclear Information System (INIS)

    Jiang, Yong; Hirshfield, Jay Leonard

    2016-01-01

    This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10"-"7/pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise Δ T. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field E_s_u_r"m"a"x< 260 MV/m and pulsed surface heating Δ T"m"a"x< 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power - as compared with operation at the same acceleration gradient using only the fundamental mode.

  8. RF BREAKDOWN STUDIES USING PRESSURIZED CAVITIES

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland

    2014-09-21

    Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Part of the problem is that RF breakdown in an evacuated cavity involves a complex mixture of effects, which include the geometry, metallurgy, and surface preparation of the accelerating structures and the make-up and pressure of the residual gas in which plasmas form. Studies showed that high gradients can be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas, as needed for muon cooling channels, without the need for long conditioning times, even in the presence of strong external magnetic fields. This positive result was expected because the dense gas can practically eliminate dark currents and multipacting. In this project we used this high pressure technique to suppress effects of residual vacuum and geometry that are found in evacuated cavities in order to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. One of the interesting and useful outcomes of this project was the unanticipated collaborations with LANL and Fermilab that led to new insights as to the operation of evacuated normal-conducting RF cavities in high external magnetic fields. Other accomplishments included: (1) RF breakdown experiments to test the effects of SF6 dopant in H2 and He gases with Sn, Al, and Cu electrodes were carried out in an 805 MHz cavity and compared to calculations and computer simulations. The heavy corrosion caused by the SF6 components led to the suggestion that a small admixture of oxygen, instead of SF6, to the hydrogen would allow the same advantages without the corrosion in a practical muon beam line. (2) A

  9. Accoustic Localization of Breakdown in Radio Frequency Accelerating Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Peter Gwin [IIT, Chicago

    2016-07-01

    Current designs for muon accelerators require high-gradient radio frequency (RF) cavities to be placed in solenoidal magnetic fields. These fields help contain and efficiently reduce the phase space volume of source muons in order to create a usable muon beam for collider and neutrino experiments. In this context and in general, the use of RF cavities in strong magnetic fields has its challenges. It has been found that placing normal conducting RF cavities in strong magnetic fields reduces the threshold at which RF cavity breakdown occurs. To aid the effort to study RF cavity breakdown in magnetic fields, it would be helpful to have a diagnostic tool which can localize the source of breakdown sparks inside the cavity. These sparks generate thermal shocks to small regions of the inner cavity wall that can be detected and localized using microphones attached to the outer cavity surface. Details on RF cavity sound sources as well as the hardware, software, and algorithms used to localize the source of sound emitted from breakdown thermal shocks are presented. In addition, results from simulations and experiments on three RF cavities, namely the Aluminum Mock Cavity, the High-Pressure Cavity, and the Modular Cavity, are also given. These results demonstrate the validity and effectiveness of the described technique for acoustic localization of breakdown.

  10. Harmonic Mode-Locked Fiber Laser based on Photonic Crystal Fiber Filled with Topological Insulator Solution

    Directory of Open Access Journals (Sweden)

    Yu-Shan Chen

    2015-04-01

    Full Text Available We reported that the photonic crystal fiber (PCF filled with TI:Bi2Te3 nanosheets solution could act as an effective saturable absorber (SA. Employing this TI-PCF SA device; we constructed an ytterbium-doped all-fiber laser oscillator and achieved the evanescent wave mode-locking operation. Due to the large cavity dispersion; the fundamental mode-locking pulse had the large full width at half maximum (FWHM of 2.33 ns with the repetition rate of ~1.11 MHz; and the radio frequency (RF spectrum with signal-to-noise ratio (SNR of 61 dB. In addition; the transition dynamics from a bunched state of pulses to harmonic mode-locking (HML was also observed; which was up to 26th order.

  11. RF Power Requirements for PEFP SRF Cavity Test

    International Nuclear Information System (INIS)

    Kim, Han Sung; Seol, Kyung Tae; Kwon, Hyeok Jung; Cho, Yong Sub

    2011-01-01

    For the future extension of the PEFP (Proton Engineering Frontier Project) Proton linac, preliminary study on the SRF (superconducting radio-frequency) cavity is going on including a five-cell prototype cavity development to confirm the design and fabrication procedures and to check the RF and mechanical properties of a low-beta elliptical cavity. The main parameters of the cavity are like followings. - Frequency: 700 MHz - Operating mode: TM010 pi mode - Cavity type: Elliptical - Geometrical beta: 0.42 - Number of cells: 5 - Accelerating gradient: 8 MV/m - Epeak/Eacc: 3.71 - Bpeak/Eacc: 7.47 mT/(MV/m) - R/Q: 102.3 ohm - Epeak: 29.68 MV/m (1.21 Kilp.) - Geometrical factor: 121.68 ohm - Cavity wall thickness: 4.3 mm - Stiffening structure: Double ring - Effective length: 0.45 m For the test of the cavity at low temperature of 4.2 K, many subsystems are required such as a cryogenic system, RF system, vacuum system and radiation shielding. RF power required to generate accelerating field inside cavity depends on the RF coupling parameters of the power coupler and quality factor of the SRF cavity and the quality factor itself is affected by several factors such as operating temperature, external magnetic field level and surface condition. Therefore, these factors should be considered to estimate the required RF power for the SRF cavity test

  12. Preparation and handling of superconducting RF cavities

    International Nuclear Information System (INIS)

    Furuya, Takaaki

    1990-01-01

    The present paper outlines the recent preparation methods for superconducting cavities used in various laboratories and universities, and reports the problems of the cavity fabrication at KEK as an example of mass production. Preparation and handling are first addressed, focusing on material, fabrication, surface treatment, rinsing, clean environment, and heat treatment. Cavity production at KEK is then described, centering on defects on the surface and clean environments. Field gradients of more than 20 MV/m have been obtained by 1.5-3 GHz single cavities, for multi-cell cavities Eacc of 10 MV/m are available at any frequency range. The successful construction of thirty-two cavities for TRISTAN at KEK is due to the careful checking of the surface and quality control of all processes against the surface defects and contaminations. Eacc of 5 MV/m has been achieved by 94 % of the TRISTAN cavities at the first cold test, but 6 % of them had to be reworked because of the surface defects. These defects could not be detected by an X-ray photograph or visual inspections during the fabrication processes. (N.K.)

  13. Hybrid vertical cavity laser

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2010-01-01

    A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide.......A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide....

  14. Status of the LCLS-II Accelerating Cavity Production

    Energy Technology Data Exchange (ETDEWEB)

    Daly, Ed [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Marhauser, Frank [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Fitzpatrick, Jarrod A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Palczewski, Ari D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Preble, Joe [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wilson, Katherine M. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Grimm, C. J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Burrill, Andrew B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Gonnella, Daniel [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2017-05-01

    Cavity serial production for the LCLS-II 4 GeV CM SRF linac has started. A quantity of 266 accelerating cavities has been ordered from two industrial vendors. Jefferson Laboratory leads the cavity procurement activities for the project and has successfully transferred the Nitrogen-Doping process to the industrial partners in the initial phase, which is now being applied for the production cavities. We report on the results from vendor qualification and the status of the cavity production for LCLS-II.

  15. Perturbed Partial Cavity Drag Reduction at High Reynolds Numbers

    Science.gov (United States)

    Makiharju, Simo; Elbing, Brian; Wiggins, Andrew; Dowling, David; Perlin, Marc; Ceccio, Steven

    2010-11-01

    Ventilated partial cavities were investigated at Reynolds numbers to 80 million. These cavities could be suitable for friction drag reduction on ocean going vessels and thereby lead to environmental and economical benefits. The test model was a 3.05 m wide by 12.9 m long flat plate, with a 0.18 m backward-facing step and a cavity-terminating beach, which had an adjustable slope, tilt and height. The step and beach trapped a ventilated partial cavity over the longitudinal mid-section of the model. Large-scale flow perturbations, mimicking the effect of ambient ocean waves were investigated. For the conditions tested a cavity could be maintained under perturbed flow conditions when the gas flux supplied was greater than the minimum required to maintain a cavity under steady conditions, with larger perturbations requiring more excess gas flux to maintain the cavity. High-speed video was used to observe the unsteady three dimensional cavity closure, the overall cavity shape, and the cavity oscillations. Cavities with friction drag reduction exceeding 95% were attained at optimal conditions. A simplified energy cost-benefit analysis of partial cavity drag reduction was also performed. The results suggest that PCDR could potentially lead to energy savings.

  16. CavityPlus: a web server for protein cavity detection with pharmacophore modelling, allosteric site identification and covalent ligand binding ability prediction.

    Science.gov (United States)

    Xu, Youjun; Wang, Shiwei; Hu, Qiwan; Gao, Shuaishi; Ma, Xiaomin; Zhang, Weilin; Shen, Yihang; Chen, Fangjin; Lai, Luhua; Pei, Jianfeng

    2018-05-10

    CavityPlus is a web server that offers protein cavity detection and various functional analyses. Using protein three-dimensional structural information as the input, CavityPlus applies CAVITY to detect potential binding sites on the surface of a given protein structure and rank them based on ligandability and druggability scores. These potential binding sites can be further analysed using three submodules, CavPharmer, CorrSite, and CovCys. CavPharmer uses a receptor-based pharmacophore modelling program, Pocket, to automatically extract pharmacophore features within cavities. CorrSite identifies potential allosteric ligand-binding sites based on motion correlation analyses between cavities. CovCys automatically detects druggable cysteine residues, which is especially useful to identify novel binding sites for designing covalent allosteric ligands. Overall, CavityPlus provides an integrated platform for analysing comprehensive properties of protein binding cavities. Such analyses are useful for many aspects of drug design and discovery, including target selection and identification, virtual screening, de novo drug design, and allosteric and covalent-binding drug design. The CavityPlus web server is freely available at http://repharma.pku.edu.cn/cavityplus or http://www.pkumdl.cn/cavityplus.

  17. Superconducting rf and beam-cavity interactions

    International Nuclear Information System (INIS)

    Bisognano, J.J.

    1987-01-01

    Beam-cavity interactions can limit the beam quality and current handling capability of linear and circular accelerators. These collective effects include cumulative and regenerative transverse beam breakup (BBU) in linacs, transverse multipass beam breakup in recirculating linacs and microtrons, longitudinal and transverse coupled-bunch instabilities in storage rings, and a variety of transverse and longitudinal single-bunch phenomena (instabilities, beam breakup, and energy deposition). The superconducting radio frequency (SRF) environment has a number of features which distinguish it from room temperature configuration with regard to these beam-cavity interactions. Typically the unloaded Qs of the lower higher order modes (HOM) are at the 10 9 level and require significant damping through couplers. High gradient CW operation, which is a principal advantage of SRF, allows for better control of beam quality, which for its preservation requires added care which respect to collective phenomena. Gradients are significantly higher than those attainable with copper in CW operation but remain significantly lower than those obtainable with pulsed copper cavities. Finally, energy deposition by the beam into the cavity can occur in a cryogenic environment. In this note those characteristics of beam-cavity interactions which are of particular importance for superconducting RF cavities are highlighted. 6 refs., 4 figs

  18. Beam induced rf cavity transient voltage

    International Nuclear Information System (INIS)

    Kramer, S.L.; Wang, J.M.

    1998-10-01

    The authors calculate the transient voltage induced in a radio frequency cavity by the injection of a relativistic bunched beam into a circular accelerator. A simplified model of the beam induced voltage, using a single tone current signal, is generated and compared with the voltage induced by a more realistic model of a point-like bunched beam. The high Q limit of the bunched beam model is shown to be related simply to the simplified model. Both models are shown to induce voltages at the resonant frequency ω r of the cavity and at an integer multiple of the bunch revolution frequency (i.e. the accelerating frequency for powered cavity operation) hω ο . The presence of two nearby frequencies in the cavity leads to a modulation of the carrier wave exp(hω ο t). A special emphasis is placed in this paper on studying the modulation function. These models prove useful for computing the transient voltage induced in superconducting rf cavities, which was the motivation behind this research. The modulation of the transient cavity voltage discussed in this paper is the physical basis of the recently observed and explained new kinds of longitudinal rigid dipole mode which differs from the conventional Robinson mode

  19. Three-Dimensional Morphology of a Coronal Prominence Cavity

    Science.gov (United States)

    Gibson, S. E.; Kucera, T. A.; Rastawicki, D.; Dove, J.; deToma, G.; Hao, J.; Hill, S.; Hudson, H. S.; Marque, C.; McIntosh, P. S.; hide

    2010-01-01

    We present a three-dimensional density model of coronal prominence cavities, and a morphological fit that has been tightly constrained by a uniquely well-observed cavity. Observations were obtained as part of an International Heliophysical Year campaign by instruments from a variety of space- and ground-based observatories, spanning wavelengths from radio to soft-X-ray to integrated white light. From these data it is clear that the prominence cavity is the limb manifestation of a longitudinally-extended polar-crown filament channel, and that the cavity is a region of low density relative to the surrounding corona. As a first step towards quantifying density and temperature from campaign spectroscopic data, we establish the three-dimensional morphology of the cavity. This is critical for taking line-of-sight projection effects into account, since cavities are not localized in the plane of the sky and the corona is optically thin. We have augmented a global coronal streamer model to include a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. We have developed a semi-automated routine that fits ellipses to cross-sections of the cavity as it rotates past the solar limb, and have applied it to Extreme Ultraviolet Imager (EUVI) observations from the two Solar Terrestrial Relations Observatory (STEREO) spacecraft. This defines the morphological parameters of our model, from which we reproduce forward-modeled cavity observables. We find that cavity morphology and orientation, in combination with the viewpoints of the observing spacecraft, explains the observed variation in cavity visibility for the east vs. west limbs

  20. Cavity-enhanced spectroscopy and sensing

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, Gianluca [CNR-Istituto Nazionale di Ottica (INO), Pozzuoli (Italy); Loock, Hans-Peter (ed.) [Queen' s Univ., Kingston, ON (Canada). Dept. of Chemistry

    2014-07-01

    The book reviews the dramatic recent advances in the use of optical resonators for high sensitivity and high resolution molecular spectroscopy as well as for chemical, mechanical and physical sensing. It encompasses a variety of cavities including those made of two or more mirrors, optical fiber loops, fiber gratings and spherical cavities. The book focuses on novel techniques and their applications. Each chapter is written by an expert and/or pioneer in the field. These experts also provide the theoretical background in optics and molecular physics where needed. Examples of recent breakthroughs include the use of frequency combs (Nobel prize 2005) for cavity enhanced sensing and spectroscopy, the use of novel cavity materials and geometries, the development of optical heterodyne detection techniques combined to active frequency-locking schemes. These methods allow the use and interrogation of optical resonators with a variety of coherent light sources for trace gas detection and sensing of strain, temperature and pressure.

  1. Cavity-enhanced spectroscopy and sensing

    CERN Document Server

    Loock, Hans-Peter

    2014-01-01

    The book reviews the dramatic recent advances in the use of optical resonators for high sensitivity and high resolution molecular spectroscopy as well as for chemical, mechanical and physical sensing.  It encompasses a variety of cavities including those made of two or more mirrors, optical fiber loops, fiber gratings and spherical cavities. The book focuses on novel techniques and their applications. Each chapter is written by an expert and/or pioneer in the field. These experts also provide the theoretical background in optics and molecular physics where needed. Examples of recent breakthroughs include the use of frequency combs (Nobel prize 2005) for cavity enhanced sensing and spectroscopy, the use of novel cavity materials and geometries, the development of optical heterodyne detection techniques combined to active frequency-locking schemes. These methods allow the use and interrogation of optical resonators with a variety of coherent light sources for trace gas detection and sensing of strain, temperat...

  2. SRF Cavity Fabrication and Materials

    CERN Document Server

    Singer, W

    2014-07-17

    The technological and metallurgical requirements of material for highgradient superconducting cavities are described. High-purity niobium, as the preferred metal for the fabrication of superconducting accelerating cavities, should meet exact specifications. The content of interstitial impurities such as oxygen, nitrogen, and carbon must be below 10μg/g. The hydrogen content should be kept below 2μg/g to prevent degradation of the Q-value under certain cool-down conditions. The material should be free of flaws (foreign material inclusions or cracks and laminations) that can initiate a thermal breakdown. Defects may be detected by quality control methods such as eddy current scanning and identified by a number of special methods. Conventional and alternative cavity fabrication methods are reviewed. Conventionally, niobium cavities are fabricated from sheet niobium by the formation of half-cells by deep drawing, followed by trim machining and Electron-Beam Welding (EBW). The welding of half-cells is a delicate...

  3. Bistability of Cavity Magnon Polaritons

    Science.gov (United States)

    Wang, Yi-Pu; Zhang, Guo-Qiang; Zhang, Dengke; Li, Tie-Fu; Hu, C.-M.; You, J. Q.

    2018-01-01

    We report the first observation of the magnon-polariton bistability in a cavity magnonics system consisting of cavity photons strongly interacting with the magnons in a small yttrium iron garnet (YIG) sphere. The bistable behaviors emerged as sharp frequency switchings of the cavity magnon polaritons (CMPs) and related to the transition between states with large and small numbers of polaritons. In our experiment, we align, respectively, the [100] and [110] crystallographic axes of the YIG sphere parallel to the static magnetic field and find very different bistable behaviors (e.g., clockwise and counter-clockwise hysteresis loops) in these two cases. The experimental results are well fitted and explained as being due to the Kerr nonlinearity with either a positive or negative coefficient. Moreover, when the magnetic field is tuned away from the anticrossing point of CMPs, we observe simultaneous bistability of both magnons and cavity photons by applying a drive field on the lower branch.

  4. Two interacting hard disks within a circular cavity: towards a quasi-equilibrium quantal equation of states

    International Nuclear Information System (INIS)

    Nakazono, Naofumi; Kato, Takeo; Nakamura, Katsuhiro

    2005-01-01

    Two interacting hard disks confined in a circular cavity are investigated. Each disk shows a free motion except when bouncing elastically with its partner and with the boundary wall. According to the analysis of Lyapunov exponents, this system is classically nonintegrable and almost chaotic because of the (short-range) interaction between the disks. The system can be quantized by incorporating the excluded volume effect for the wave function. Eigenvalues and eigenfunctions are obtained by tuning the relative size between the disks and the billiard. The pressure P is defined as the derivative of each eigenvalue with respect to the cavity volume V. Since the energy spectra of eigenvalues versus the disk size show a multitude of level repulsions, P-V characteristics shows the anomalous pressure fluctuations accompanied by many van der Waals-like peaks in each of excited eigenstates taken as a quasi-equilibrium. For each eigenstate, we calculate the expectation values of the square distance between two disks, and point out their relationship with the pressure fluctuations. Role of Bose and Fermi statistics is also investigated

  5. Comparison of Wenner and dipole–dipole arrays in the study of an underground three-dimensional cavity

    International Nuclear Information System (INIS)

    Neyamadpour, Ahmad; Wan Abdullah, W A T; Taib, Samsudin; Neyamadpour, Behrang

    2010-01-01

    The objective of this paper was to compare Wenner and dipole–dipole configurations in delineating an underground cavity at a site near the University of Malaya, Malaysia. A three-dimensional electrical resistivity imaging survey was carried out along seven parallel lines using Wenner and dipole–dipole arrays. A three-dimensional least-squares algorithm, based on the robust inversion method, was used in the inversion of the apparent resistivity data. In the inverted model, both the horizontal and vertical extents of the anomalous zones were displayed. Results indicate the superiority of the Wenner array over the dipole–dipole array for determining the vertical distribution of the subsurface resistivity, although the dipole–dipole array produced a better lateral extent of the subsurface features. The results show that the three-dimensional electrical resistivity imaging survey using both the Wenner and dipole–dipole arrays, in combination with an appropriate three-dimensional inversion method and synthetic model analysis, can be highly useful for engineering and environmental applications, especially for underground three-dimensional cavity detection

  6. The CEBAF Separator Cavity Resonance Control System

    CERN Document Server

    Wissmann, Mark J; Hovater, Curt; Plawski, Tomasz

    2005-01-01

    The CEBAF energy upgrade from 6 GeV to 12GeV will increase the range of beam energies available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three experimental halls. Consequently with the increase in RF separator cavity gradient needed for the higher energies, RF power will also increase requiring the cavities to have active resonance control. At the 6 GeV energy, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW), which is maintained at constant temperature of 95o Fahrenheit. This is no longer feasible and an active resonance control system, that controls both water temperature and flow has been built. The system uses a commercial PLC with embedded PID controls to control water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately closed loop control will be maintained by monit...

  7. Cantilever piezoelectric energy harvester with multiple cavities

    International Nuclear Information System (INIS)

    S Srinivasulu Raju; M Umapathy; G Uma

    2015-01-01

    Energy harvesting employing piezoelectric materials in mechanical structures such as cantilever beams, plates, diaphragms, etc, has been an emerging area of research in recent years. The research in this area is also focused on structural tailoring to improve the harvested power from the energy harvesters. Towards this aim, this paper presents a method for improving the harvested power from a cantilever piezoelectric energy harvester by introducing multiple rectangular cavities. A generalized model for a piezoelectric energy harvester with multiple rectangular cavities at a single section and two sections is developed. A method is suggested to optimize the thickness of the cavities and the number of cavities required to generate a higher output voltage for a given cantilever beam structure. The performance of the optimized energy harvesters is evaluated analytically and through experimentation. The simulation and experimental results show that the performance of the energy harvester can be increased with multiple cavities compared to the harvester with a single cavity. (paper)

  8. Driven-Dissipative Supersolid in a Ring Cavity

    Science.gov (United States)

    Mivehvar, Farokh; Ostermann, Stefan; Piazza, Francesco; Ritsch, Helmut

    2018-03-01

    Supersolids are characterized by the counterintuitive coexistence of superfluid and crystalline order. Here we study a supersolid phase emerging in the steady state of a driven-dissipative system. We consider a transversely pumped Bose-Einstein condensate trapped along the axis of a ring cavity and coherently coupled to a pair of degenerate counterpropagating cavity modes. Above a threshold pump strength the interference of photons scattered into the two cavity modes results in an emergent superradiant lattice, which spontaneously breaks the continuous translational symmetry towards a periodic atomic pattern. The crystalline steady state inherits the superfluidity of the Bose-Einstein condensate, thus exhibiting genuine properties of a supersolid. A gapless collective Goldstone mode correspondingly appears in the superradiant phase, which can be nondestructively monitored via the relative phase of the two cavity modes on the cavity output. Despite cavity-photon losses the Goldstone mode remains undamped, indicating the robustness of the supersolid phase.

  9. Radiopacity of root filling materials

    International Nuclear Information System (INIS)

    Beyer-Olsen, E.M.

    1983-01-01

    A method for measuring the radiopacity of root filling materials is described. Direct measurements were made of the optic density values of the materials in comparison with a standard curve relating optic density to the thickness of an aluminium step wedge exposed simultaneously. By proper selection of film and conditions for exposure and development, it was possible to obtain a near-linear standard curve which added to the safety and reproducibility of the method. The technique of radiographic assessment was modified from clinical procedures in evaluating the obturation in radiographs, and it was aimed at detecting slits or voids between the dental wall and the filling material. This radiographic assessment of potensial leakage was compared with actual in vitro lekage of dye (basic fuchsin) into the roots of filled teeth. The result of the investigation show that root filling materials display a very wide range of radiopacity, from less than 3 mm to more than 12 mm of aluminium. It also seem that tooth roots that appear to be well obturated by radiographic evaluation, stand a good chance of beeing resistant to leakage in vitro, and that the type of filling material rather than its radiographic appearance, determines the susceptibility of the filled tooth to leakage in vitro. As an appendix the report contains a survey of radiopaque additives in root filling materials

  10. Effects of cavity surface temperature on mechanical properties of specimens with and without a weld line in rapid heat cycle molding

    International Nuclear Information System (INIS)

    Wang, Guilong; Zhao, Guoqun; Wang, Xiaoxin

    2013-01-01

    Highlights: ► Higher cavity surface temperature reduces tensile strength of non-weldline part. ► Higher cavity surface temperature increases weldline tensile strength for PS and PP. ► Higher cavity surface temperature reduces weldline tensile strength for ABS, ABS/PMMA, ABS/PMMA/nano-C a CO 3 and FRPP. ► Tensile strength is reduced more by the weldline than impact strength. ► FRPP has the lowest weld line factor than other plastics without reinforced fibers. - Abstract: Rapid heat cycle molding (RHCM) is a recently developed injection molding technology to enhance surface esthetic of the parts. By rapid heating and cooling of mold cavity surfaces in molding process, it can greatly alleviate or even eliminate the surface defects such as flow mark, weld line, glass fiber rich surface, silver mark, jetting mark, and swirl mark, and also improve gloss finish and dimensional accuracy without prolonging the molding cycle. Besides surface esthetic, mechanical property is also a very import issue for the molded plastic part. The aim of this study is focusing on the effects of the cavity surface temperature just before filling, T cs , in RHCM on the mechanical strength of the specimen with and without weld line. Six kinds of typical plastics including polystyrene (PS), polypropylene (PP), acrylonitrile butadiene styrene (ABS), acrylonitrile butadiene styrene/polymethylmethacrylate (ABS/PMMA), ABS/PMMA/nano-C a CO 3 and glass fiber reinforced polypropylene (FRPP) are used in experiments. The specimens with and without a weld line are produced with the different T cs on the developed electric-heating RHCM system. Tensile tests and notched Izod impact tests are conducted to characterize the mechanical strength of the specimens molded with different cavity surface temperatures. Simulations, differential scanning calorimetry (DSC), scanning electron microscope (SEM) and optical microscope are implemented to explain the impact mechanism of T cs on mechanical properties

  11. SRF Cavity Fabrication and Materials

    Energy Technology Data Exchange (ETDEWEB)

    Singer, W [DESY (Germany)

    2014-07-01

    The technological and metallurgical requirements of material for highgradient superconducting cavities are described. High-purity niobium, as the preferred metal for the fabrication of superconducting accelerating cavities, should meet exact specifications. The content of interstitial impurities such as oxygen, nitrogen, and carbon must be below 10μg/g. The hydrogen content should be kept below 2μg/g to prevent degradation of the Q-value under certain cool-down conditions. The material should be free of flaws (foreign material inclusions or cracks and laminations) that can initiate a thermal breakdown. Defects may be detected by quality control methods such as eddy current scanning and identified by a number of special methods. Conventional and alternative cavity fabrication methods are reviewed. Conventionally, niobium cavities are fabricated from sheet niobium by the formation of half-cells by deep drawing, followed by trim machining and Electron-Beam Welding (EBW). The welding of half-cells is a delicate procedure, requiring intermediate cleaning steps and a careful choice of weld parameters to achieve full penetration of the joints. The equator welds are particularly critical. A challenge for a welded construction is the tight mechanical and electrical tolerances. These can be maintained by a combination of mechanical and radio-frequency measurements on halfcells and by careful tracking of weld shrinkage. The established procedure is suitable for large series production. The main aspects of quality assurance management are mentioned. Another cavity fabrication approach is slicing discs from the ingot and producing cavities by deep drawing and EBW. Accelerating gradients at the level of 35–45 MV·m–1 can be achieved by applying Electropolishing (EP) treatment. Furthermore, the single-crystal option (grain boundary free) is promising. It seems that in this case, high performance can be achieved by a simplified treatment procedure. Fabrication of the

  12. Design of 325 MHz spoke cavity

    International Nuclear Information System (INIS)

    Sha Peng; Huang Hong; Dai Jianping; Zu Guoquan; Li Han

    2012-01-01

    Spoke cavity can be used in the low-energy section of the proton accelerator. It has many significant advantages: compact structure, high value of R/Q, etc. The ADS (Accelerator Driven System) project will adopt many spoke cavities with different β values. Therefore, IHEP has began the research of β=0.14, 325 MHz spoke cavity. In this pa per, the dimensions, RF performances and mechanical properties of it are studied. (authors)

  13. A superconducting test cavity for DORIS

    International Nuclear Information System (INIS)

    Bauer, W.; Brandelik, A.; Lekmann, W.; Szecsi, L.

    1978-03-01

    A summary of experimental goals, technical requirements and possible solutions for the construction of a superconducting accelerating cavity to be tested at DORIS is given. The aim of the experiment is to prove the applicability of superconducting cavities in storage rings and to study the problems typical for this application. The paper collects design considerations about cavity geometry and fabrication, input coupling, output coupling for higher modes, tuner, cryostat and controls. (orig.) [de

  14. Self-diffusion of particles interacting through a square-well or square-shoulder potential

    NARCIS (Netherlands)

    Wilbertz, H.; Michels, J.; Beijeren, H. van; Leegwater, J.A.

    1988-01-01

    The diffusion coefficient and velocity autocorrelation function for a fluid of particles interacting through a square-well or square-shoulder potential are calculated from a kinetic theory similar to the Davis-Rice-Sengers theory and the results are compared to those of computer simulations. At low

  15. JLab SRF Cavity Fabrication Errors, Consequences and Lessons Learned

    International Nuclear Information System (INIS)

    Marhauser, Frank

    2011-01-01

    Today, elliptical superconducting RF (SRF) cavities are preferably made from deep-drawn niobium sheets as pursued at Jefferson Laboratory (JLab). The fabrication of a cavity incorporates various cavity cell machining, trimming and electron beam welding (EBW) steps as well as surface chemistry that add to forming errors creating geometrical deviations of the cavity shape from its design. An analysis of in-house built cavities over the last years revealed significant errors in cavity production. Past fabrication flaws are described and lessons learned applied successfully to the most recent in-house series production of multi-cell cavities.

  16. Fast thermometry for superconducting rf cavity testing

    International Nuclear Information System (INIS)

    Orris, Darryl; Bellantoni, Leo; Carcagno, Ruben H.; Edwards, Helen; Harms, Elvin Robert; Khabiboulline, Timergali N.; Kotelnikov, Sergey; Makulski, Andrzej; Nehring, Roger; Pischalnikov, Yuriy; Fermilab

    2007-01-01

    Fast readout of strategically placed low heat capacity thermometry can provide valuable information of Superconducting RF (SRF) cavity performance. Such a system has proven very effective for the development and testing of new cavity designs. Recently, several resistance temperature detectors (RTDs) were installed in key regions of interest on a new 9 cell 3.9 GHz SRF cavity with integrated HOM design at FNAL. A data acquisition system was developed to read out these sensors with enough time and temperature resolution to measure temperature changes on the cavity due to heat generated from multipacting or quenching within power pulses. The design and performance of the fast thermometry system will be discussed along with results from tests of the 9 cell 3.9GHz SRF cavity

  17. Fast thermometry for superconducting rf cavity testing

    Energy Technology Data Exchange (ETDEWEB)

    Orris, Darryl; Bellantoni, Leo; Carcagno, Ruben H.; Edwards, Helen; Harms, Elvin Robert; Khabiboulline, Timergali N.; Kotelnikov, Sergey; Makulski, Andrzej; Nehring, Roger; Pischalnikov, Yuriy; /Fermilab

    2007-06-01

    Fast readout of strategically placed low heat capacity thermometry can provide valuable information of Superconducting RF (SRF) cavity performance. Such a system has proven very effective for the development and testing of new cavity designs. Recently, several resistance temperature detectors (RTDs) were installed in key regions of interest on a new 9 cell 3.9 GHz SRF cavity with integrated HOM design at FNAL. A data acquisition system was developed to read out these sensors with enough time and temperature resolution to measure temperature changes on the cavity due to heat generated from multipacting or quenching within power pulses. The design and performance of the fast thermometry system will be discussed along with results from tests of the 9 cell 3.9GHz SRF cavity.

  18. XAFS study of copper(II) complexes with square planar and square pyramidal coordination geometries

    Science.gov (United States)

    Gaur, A.; Klysubun, W.; Nitin Nair, N.; Shrivastava, B. D.; Prasad, J.; Srivastava, K.

    2016-08-01

    X-ray absorption fine structure of six Cu(II) complexes, Cu2(Clna)4 2H2O (1), Cu2(ac)4 2H2O (2), Cu2(phac)4 (pyz) (3), Cu2(bpy)2(na)2 H2O (ClO4) (4), Cu2(teen)4(OH)2(ClO4)2 (5) and Cu2(tmen)4(OH)2(ClO4)2 (6) (where ac, phac, pyz, bpy, na, teen, tmen = acetate, phenyl acetate, pyrazole, bipyridine, nicotinic acid, tetraethyethylenediamine, tetramethylethylenediamine, respectively), which were supposed to have square pyramidal and square planar coordination geometries have been investigated. The differences observed in the X-ray absorption near edge structure (XANES) features of the standard compounds having four, five and six coordination geometry points towards presence of square planar and square pyramidal geometry around Cu centre in the studied complexes. The presence of intense pre-edge feature in the spectra of four complexes, 1-4, indicates square pyramidal coordination. Another important XANES feature, present in complexes 5 and 6, is prominent shoulder in the rising part of edge whose intensity decreases in the presence of axial ligands and thus indicates four coordination in these complexes. Ab initio calculations were carried out for square planar and square pyramidal Cu centres to observe the variation of 4p density of states in the presence and absence of axial ligands. To determine the number and distance of scattering atoms around Cu centre in the complexes, EXAFS analysis has been done using the paths obtained from Cu(II) oxide model and an axial Cu-O path from model of a square pyramidal complex. The results obtained from EXAFS analysis have been reported which confirmed the inference drawn from XANES features. Thus, it has been shown that these paths from model of a standard compound can be used to determine the structural parameters for complexes having unknown structure.

  19. Estimating tree cavity distributions from historical FIA data

    Science.gov (United States)

    Mark D. Nelson; Charlotte. Roy

    2012-01-01

    Tree cavities provide important habitat features for a variety of wildlife species. We describe an approach for using historical FIA data to estimate the number of trees containing cavities during the 1990s in seven states of the Upper Midwest. We estimated a total of 280 million cavity-containing trees. Iowa and Missouri had the highest percentages of cavity-...

  20. Estimation of water-filled and air-filled porosity in the unsaturated zone, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Nelson, P.H.

    1993-01-01

    Water content and porosity vary considerably within the unsaturated zone at Yucca Mountain. Measurement of these quantities has been based on core samples. A log-based approach offers the advantage of in-situ measurements, continuous throughout the borehole. This paper describes an algorithm which determines the air-filled and water-filled porosities from density and dielectric logs. The responses of density and dielectric logs are formulated in terms of the matrix properties, air-filled porosity and water-filled porosity. Porosity values obtained from logs from borehole USW G-2 are in reasonable agreement with estimates from core determinations