WorldWideScience

Sample records for spray bottle apparatus

  1. Is nasal steroid spray bottle contamination a potential issue in chronic rhinosinusitis?

    Science.gov (United States)

    Tan, N C-W; Drilling, A J; Jardeleza, C; Wormald, P-J

    2014-01-01

    Intranasal steroids are the first line of treatment for chronic rhinosinusitis. Although contamination of adjunctive devices (e.g. irrigation bottles) has been much investigated, little is known about nasal contamination of the metered-dose spray bottles used to deliver intranasal steroids, and the potential influence on disease chronicity. Twenty-five prospectively recruited patients with stable chronic rhinosinusitis underwent microbiological analysis of their nasal vestibule and middle meatus and also of their steroid bottle tip and contents. Additionally, bottle tips were inoculated in vitro with Staphylococcus aureus and various sterilisation techniques tested. For 18 of the 25 (72 per cent) patients, both nasal and bottle tip swabs grew either Staphylococcus aureus or coagulase-negative staphylococci. Staphylococcus aureus was cultured from 7 of the 25 (28 per cent) patients, and 5 of these 7 had concomitant bacterial growth from both nose and steroid bottle. Thus, the cross-contamination rate was 71 per cent for Staphylococcus aureus infected patients and 20 per cent overall. Sterilisation was effective with boiling water, ethanol wipes and microwaving, but not with cold water or dishwashing liquid. Nasal steroid spray bottle tips can become contaminated with sinonasal cavity bacteria. Simple sterilisation methods can eliminate this contamination. Patient education on this matter should be emphasised.

  2. Squeeze bottle versus saline spray after endoscopic sinus surgery for chronic rhinosinusitis: a pilot multicentre trial.

    Science.gov (United States)

    Macdonald, K I; Wright, E D; Sowerby, L J; Rotenberg, B W; Chin, C J; Rudmik, L; Sommer, D D; Nayan, S; DesRosiers, M; Tewfik, M A; Valdes, C J; Massoud, E; Thomas, D; Kilty, S J; Vescan, A; Mechor, B; Lavigne, F; Fandino, M; Javer, A R; Witterick, I J

    2015-01-01

    There is a need for controlled trials to guide the perioperative management of patients undergoing endoscopic sinus surgery (ESS). The authors performed a pilot multicenter trial to compare two types of saline delivery devices in this population. Patients were randomized to high volume saline irrigation with a squeeze bottle and low volume saline spray after ESS in patients with chronic rhinosinusitis (CRS). Surgeons were blinded to treatment, and one-month postoperative scores for sinonasal outcomes [Sinonasal Outcome Test-22 (SNOT-22)] scale, nasal and sinus symptom score (NSS), and perioperative sinus endoscopy (POSE) scale were compared with preoperative scores. Nine centers provided data for 86 patients. All three outcomes measures improved significantly for both groups. Saline spray: SNOT-22 48.8 versus. 23.7, treatment effect 25.1 (95% confidence interval [CI], 17.9-32.2), POSE 21.1 versus. 8.4, treatment effect 12.7 (95% CI, 9.2-16.1), and NSS 8.2 versus 5.0, treatment effect 3.1 (95% CI, 1.4-4.9) pre- and postoperatively, respectively (all p spray showed significant improvement in SNOT-22, POSE, and NSS scores at one-month postoperatively. Because the study was nonpowered, we cannot rule out a potential difference between the two treatment groups.

  3. Method and apparatus for heat extraction by controlled spray cooling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-30

    Two solutions to the problem of cooling a high temperature, high heat flux surface using controlled spray cooling are presented for use on a mandrel. In the first embodiment, spray cooling is used to provide a varying isothermal boundary layer on the side portions of a mandrel by providing that the spray can be moved axially along the mandrel. In the second embodiment, a spray of coolant is directed to the lower temperature surface of the mandrel. By taking advantage of super-Leidenfrost cooling, the temperature of the high temperature surface of the mandrel can be controlled by varying the mass flux rate of coolant droplets. The invention has particular applicability to the field of diamond synthesis using chemical vapor deposition techniques.

  4. An Apparatus to Measure Thermal Conductivity of Spray-On Foam Insulation

    Science.gov (United States)

    Barrios, M.; Sciver, S. W. Van

    2010-04-01

    A guarded-hot-plate apparatus has been developed to measure the thermal conductivity of various spray-on foam insulations (SOFI) at temperatures ranging from 20-300 K. The apparatus is designed to accept 222 mm (8.75″) diameter, 25.4 mm (1″) thick insulation samples, although different thicknesses can be accommodated. The apparatus is cooled with a two stage, pulse tube cryocooler, and the temperature is controlled with thin film etched foil heaters. This system allows thermal conductivity measurements to be made at low delta-T (ΔTheat flow axially through the sample. A gas handling system allows testing with different residual gases and pressures. To check for potential systematic errors, a finite element analysis was performed to examine temperature distribution and heat flow in the experimental chamber.

  5. Novel spraying apparatus to investigate the lubricant deposition on metal sheets at high temperature

    Science.gov (United States)

    Medea, Francesco; Ghiotti, Andrea; Bruschi, Stefania; Bellin, Marco

    2016-10-01

    The constant demand of increasing performances and safety in automotive industry has led significant innovations in the materials as well as in forming processes. In particular, lightweight aluminium alloys are knowing higher and higher importance, thanks to the development of new stamping processes at high temperatures capable to allow improved formability, low spring-back and accurate micro-structural control in the formed parts. However, the choice of proper process parameters, in terms of lubrication at the interfaces between the dies and the blank, still represents a critical point for the process feasibility. On this basis, the paper aims at presenting a novel spraying apparatus to investigate the deposition of lubricants in hot stamping. The equipment allows the accurate control of the quantity of the lubricant that is deposited on the specimen and of the deposition temperature to maximize the lubricant adhesion. The results show the capability of the new equipment and the good stability of the conditions during testing.

  6. A new apparatus to induce lysis of planktonic microbial cells by shock compression, cavitation and spray

    Science.gov (United States)

    Schiffer, A.; Gardner, M. N.; Lynn, R. H.; Tagarielli, V. L.

    2017-03-01

    Experiments were conducted on an aqueous growth medium containing cultures of Escherichia coli (E. coli) XL1-Blue, to investigate, in a single experiment, the effect of two types of dynamic mechanical loading on cellular integrity. A bespoke shock tube was used to subject separate portions of a planktonic bacterial culture to two different loading sequences: (i) shock compression followed by cavitation, and (ii) shock compression followed by spray. The apparatus allows the generation of an adjustable loading shock wave of magnitude up to 300 MPa in a sterile laboratory environment. Cultures of E. coli were tested with this apparatus and the spread-plate technique was used to measure the survivability after mechanical loading. The loading sequence (ii) gave higher mortality than (i), suggesting that the bacteria are more vulnerable to shear deformation and cavitation than to hydrostatic compression. We present the results of preliminary experiments and suggestions for further experimental work; we discuss the potential applications of this technique to sterilize large volumes of fluid samples.

  7. Metal spray apparatus with a U-shaped electric inlet gas heater and a one-piece electric heater surrounding a nozzle

    Science.gov (United States)

    Glovan, Ronald J.; Tierney, John C.; McLean, Leroy L.; Johnson, Lawrence L.; Verbael, David J.

    1995-01-01

    An electrically heated metal spray apparatus is provided with a supersonic nozzle. Molten metal is injected into a gas stream flowing through the nozzle under pressure. By varying the pressure of the injected metal, the droplet can be made in various selected sizes with each selected size having a high degree of size uniformity. A unique one piece graphite heater provides easily controlled uniformity of temperature in the nozzle and an attached tundish which holds the pressurized molten metal. A unique U-shaped gas heater provides extremely hot inlet gas temperatures to the nozzle. A particularly useful application of the spray apparatus is coating of threads of a fastener with a shape memory alloy. This permits a fastener to be easily inserted and removed but provides for a secure locking of the fastener in high temperature environments.

  8. In situ Measurements of Residual Stresses and Elelastic Moduli in Thermal Sprayed Coatings. Part 1: Apparatus and Analysis

    Czech Academy of Sciences Publication Activity Database

    Matějíček, Jiří; Sampath, S.

    2003-01-01

    Roč. 51, č. 3 (2003), s. 863-872 ISSN 1359-6454 Grant - others:NSF(US) DMR9632570 Institutional research plan: CEZ:AV0Z2043910 Keywords : coatings plasma spraying, mechanical properties testing , elastic modulus Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 3.059, year: 2003

  9. Bottled Water and Fluoride

    Science.gov (United States)

    ... What's this? Submit What's this? Submit Button Bottled Water Recommend on Facebook Tweet Share Compartir Consumers drink ... questions about bottled water and fluoride. Does bottled water contain fluoride? Bottled water products may contain fluoride, ...

  10. Spray process for the recovery of CO.sub.2 from a gas stream and a related apparatus

    Science.gov (United States)

    Soloveichik, Grigorii Lev; Perry, Robert James; Wood, Benjamin Rue; Genovese, Sarah Elizabeth

    2014-02-11

    A method for recovering carbon dioxide (CO.sub.2) from a gas stream is disclosed. The method includes the step of reacting CO.sub.2 in the gas stream with fine droplets of a liquid absorbent, so as to form a solid material in which the CO.sub.2 is bound. The solid material is then transported to a desorption site, where it is heated, to release substantially pure CO.sub.2 gas. The CO.sub.2 gas can then be collected and used or transported in any desired way. A related apparatus for recovering carbon dioxide (CO.sub.2) from a gas stream is also described herein.

  11. Green Fiber Bottle

    DEFF Research Database (Denmark)

    Didone, Mattia; Tosello, Guido

    The ambition of the Green Fiber Bottle (GFB) project is to manufacture a fully biodegradable bottle. Carlsberg is the intended end user, and they aim to package their beer in the new bottle. The new product is intended to replace the existing plastic and glass bottles, and thus reducing...... their impact on the environment, especially the oceans. For example, the life span of a plastic bottle in the ocean is 500 years, and during its degradation, the plastic is reduced to micro pieces, which causes the starvation of several marine animals. The new bottle is completely made from molded paper pulp......, which is a renewable resource. Nevertheless, due to food and drugs limitations, only virgin paper fibers must be employed in the production. The bottle could then be left to biodegrade in nature or enter a recycle system, along with other paper-based product. In order to contain the liquid, the bottle...

  12. Security of bottle to fill in a high pressure air

    Science.gov (United States)

    Todic, M.; Latinovic, T.; Golubovic-Bugarski, V.; Majstorovic, A.

    2018-01-01

    Charging the bottle of high pressure air isolation devices is performed by a high-pressure compressor. The charging time is in function of the compressor capacity and the intensity of the nominal pressure of the air in the bottle. However, in accident situations this time is long and therefore high-pressure accumulators are used where the filling time of the bottle of isolation apparatus has been drastically reduced. Due to the short filling time of the bottle through the air flow, there is a thermodynamic load of bottle material that could endanger the safety of users and other participants in the area. It is therefore necessary to determine the critical parameters of the rapid charge and their intensity.

  13. Spray Deflector For Water-Jet Machining

    Science.gov (United States)

    Cawthon, Michael A.

    1989-01-01

    Disk on water-jet-machining nozzle protects nozzle and parts behind it from erosion by deflected spray. Consists of stainless-steel backing with neoprene facing deflecting spray so it does not reach nut or other vital parts of water-jet apparatus.

  14. Spray cooling

    International Nuclear Information System (INIS)

    Rollin, Philippe.

    1975-01-01

    Spray cooling - using water spraying in air - is surveyed as a possible system for make-up (peak clipping in open circuit) or major cooling (in closed circuit) of the cooling water of the condensers in thermal power plants. Indications are given on the experiments made in France and the systems recently developed in USA, questions relating to performance, cost and environmental effects of spray devices are then dealt with [fr

  15. Playing musical bottles

    CERN Document Server

    Rowe, Brooke

    2016-01-01

    "Each book in the My Science Fun series includes a simple experiment for the earliest readers. This book features step by step instructions on making a set of musical bottles while encouraging further exploration on the topic. Simple sentence structure and word usage help children develop word recognition and reading skills."-- Provided by publisher.

  16. Fluid Dynamics of Bottle Filling

    Science.gov (United States)

    McGough, Patrick; Gao, Haijing; Appathurai, Santosh; Basaran, Osman

    2011-11-01

    Filling of bottles is a widely practiced operation in a large number of industries. Well known examples include filling of ``large'' bottles with shampoos and cleaners in the household products and beauty care industries and filling of ``small'' bottles in the pharmaceutical industry. Some bottle filling operations have recently drawn much attention from the fluid mechanics community because of the occurrence of a multitude of complex flow regimes, transitions, and instabilities such as mounding and coiling that occur as a bottle is filled with a fluid. In this talk, we present a primarily computational study of the fluid dynamical challenges that can arise during the rapid filling of bottles. Given the diversity of fluids used in filling applications, we consider four representative classes of fluids that exhibit Newtonian, shear-thinning, viscoelastic, and yield-stress rheologies. The equations governing the dynamics of bottle filling are solved either in their full 3D but axisymmetric form or using the slender-jet approximation.

  17. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  18. Bottles of life: where plastic bottles battle bacteria | Wamanji ...

    African Journals Online (AJOL)

    Bottles of life: where plastic bottles battle bacteria. Eric Wamanji. Abstract. No Abstract. Discovery and Innovation Vol. 18(2) 2006: 80-82. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/dai.v18i2.15708 · AJOL African Journals Online. HOW TO ...

  19. High mass throughput particle generation using multiple nozzle spraying

    Science.gov (United States)

    Pui, David Y.H.; Chen, Da-Ren

    2004-07-20

    Spraying apparatus and methods that employ multiple nozzle structures for producing multiple sprays of particles, e.g., nanoparticles, for various applications, e.g., pharmaceuticals, are provided. For example, an electrospray dispensing device may include a plurality of nozzle structures, wherein each nozzle structure is separated from adjacent nozzle structures by an internozzle distance. Sprays of particles are established from the nozzle structures by creating a nonuniform electrical field between the nozzle structures and an electrode electrically isolated therefrom.

  20. Microgrooved plasmonic bottle microresonator

    Science.gov (United States)

    Mohd Nasir, M. N.; Ding, M.; Murugan, G. S.; Zervas, M. N.

    2015-06-01

    In this paper, we demonstrate an enhancement to SPW cavity through the incorporation of high-Q WGM bottle microresonator (BMR) with surface microgrooves. A standard BMR fabricated through the “soften-and-compress” technique with initial length of 280 μm, bottle diameter of 187 μm and stem diameter of 125 μm was utilized in the experiment for supporting WGMs. Thin gold film was deposited on top of the BMR for generating SPWs. 21 microgrooves was then inscribed on the metal surface of the BMR along the azimuthal direction with 10 μm length, 485 nm width, 6 μm depth and pitch of 1.5 μm. Due to surface curvature, the gold film only covered half of the BMR with a characteristic meniscus shape and maximum thickness of 30 nm. The meniscus provides appropriately tapered metal edges that facilitate the adiabatic transformation of BMR WGMs to SPWs and vice-versa. Lorentzian shape-line fit performed on the TM excited resonances show that plasmonic Q values in excess of 4000 could be achieved from such structure with ∼ 25% coupling efficiency.

  1. Training apparatus

    International Nuclear Information System (INIS)

    Monteith, W.D.

    1983-01-01

    Training apparatus for use in contamination surveillance uses a mathematical model of a hypothetical contamination source (e.g. nuclear, bacteriological or chemical explosion or leak) to determine from input data defining the contamination source, the contamination level at any location within a defined exercise area. The contamination level to be displayed by the apparatus is corrected to real time from a real time clock or may be displayed in response to a time input from a keyboard. In a preferred embodiment the location is defined by entering UTM grid reference coordinates using the keyboard. The mathematical model used by a microprocessor of the apparatus for simulation of contamination levels in the event of a nuclear explosion is described. (author)

  2. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  3. Radiotherapy apparatus

    International Nuclear Information System (INIS)

    Leung, P.M.; Webb, H.P.J.

    1985-01-01

    This invention relates to apparatus for applying intracavitary radiotherapy. In previously-known systems radioactive material is conveyed to a desired location within a patient by transporting a chain of balls pneumatically to and from an appropriately inserted applicator. According to this invention a ball chain for such a purpose comprises several radioactive balls separated by non-radioactive tracer balls of radiographically transparent material of lower density and surface hardness than the radioactive balls. The invention also extends to radiotherapy treatment apparatus comprising a storage, sorting and assembly system

  4. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  5. 27 CFR 25.142 - Bottles.

    Science.gov (United States)

    2010-04-01

    ... TREASURY LIQUORS BEER Marks, Brands, and Labels § 25.142 Bottles. (a) Label requirements. Each bottle of... bottle, the nature of the product such as beer, ale, porter, stout, etc., and the place of production... beer within the bottle except for variations in measuring as may occur in filling conducted in...

  6. Monitoring apparatus

    International Nuclear Information System (INIS)

    Keats, A.B.

    1981-01-01

    An improved monitoring apparatus for use with process plants, such as nuclear reactors, is described. System failure in the acquisition of data from the plant, owing to stuck signals, is avoided by arranging input signals from transducers in the plant in a test pattern. (U.K.)

  7. Prehensile apparatus

    Science.gov (United States)

    Smith, C.M.

    1993-10-12

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized. 8 figures.

  8. Beers Straight from the Bottle

    OpenAIRE

    Murphy, James Peter

    2007-01-01

    Consuming beer straight from the bottle a trend initiated by the US is now an accepted practice throughout Irish bars but that does not necessarily mean it is a good thing from either a hygiene or taste viewpoint.

  9. Breaking beer bottles with cavitation

    Science.gov (United States)

    Jung, Sunny; Fontana, Jake; Palffy-Muhoray, Peter; Shelley, Michael

    2009-03-01

    Hitting the top of a beer bottle, nearly full of water, with an open hand can cause the bottle to break, with the bottom separating from upper section. We have studied this phenomenon using a high-speed camera, and observed the formation, coalescence and collapse of bubbles. The breaking of glass is due to cavitation, typically occurring near the bottom edge. We make numerical estimates of the relevant physical parameters, and compare these with experimental observations.

  10. Radiography apparatus

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1985-01-01

    Apparatus for the inspection of pipe welds comprises a radiation source for transmitting radiation, say as X-rays, through a pipe weld and a detector in a box arranged diametrically opposite the source, with respect to the pipe, for detecting the transmitted radiation and providing electrical signals which are processed to produce an image of the weld. The source and detector are mounted on a frame which is rotatable about an inner frame clamped to the pipe. (author)

  11. Nicotine Nasal Spray

    Science.gov (United States)

    Nicotine nasal spray is used to help people stop smoking. Nicotine nasal spray should be used together with a ... support groups, counseling, or specific behavior change techniques. Nicotine nasal spray is in a class of medications ...

  12. A Plastic Bottle in Rectosigmoid

    Directory of Open Access Journals (Sweden)

    A. Derakhshanfar

    2007-07-01

    Full Text Available Introduction: Evaluation and treatment of foreign bodies in rectum involves careful history and physical examination. The cases of forced introduction of the objects most commonly are , sexual assault , self – introduced for anal eroticism and accidental insertion.Case Report: We describe a case of a patient with rectal impaction following self administration of a plastic bottle for anal sexual gratification. A 49 years old man was admitted in the emergency department with the history of self introduced a bottle into his rectum physical examination and abdominal X-Ray diagnosed the case as impacted foreign body in rectosigmoid. An attempt was made to deliver the bottle through the rectum but because of high lying big bottle in the sigmoid laporotomy was performed and the bottle was removed though a longitudinal incision on sigmoid colon.Conclusion: Retained rectosigmoid foreign bodies have been encountered more frequently and present a dilemma for management and rarely laporotomy for extraction of foreign bodies was performed.

  13. Positioning apparatus

    Science.gov (United States)

    Vogel, Max A.; Alter, Paul

    1986-01-01

    An apparatus for precisely positioning materials test specimens within the optimum neutron flux path emerging from a neutron source located in a housing. The test specimens are retained in a holder mounted on the free end of a support pivotably mounted and suspended from a movable base plate. The support is gravity biased to urge the holder in a direction longitudinally of the flux path against the housing. Means are provided for moving the base plate in two directions to effect movement of the holder in two mutually perpendicular directions normal to the axis of the flux path.

  14. 27 CFR 31.232 - Wine bottling.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Wine bottling. 31.232... OF THE TREASURY LIQUORS ALCOHOL BEVERAGE DEALERS Miscellaneous § 31.232 Wine bottling. Each person desiring to bottle, package, or repackage taxpaid wines must, before carrying on those operations, apply...

  15. 21 CFR 165.110 - Bottled water.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Bottled water. 165.110 Section 165.110 Food and... CONSUMPTION BEVERAGES Requirements for Specific Standardized Beverages § 165.110 Bottled water. (a) Identity—(1) Description. Bottled water is water that is intended for human consumption and that is sealed in...

  16. Green fiber bottle: Towards a sustainable package

    DEFF Research Database (Denmark)

    Didone, Mattia; Tosello, Guido; Howard, Thomas J.

    The Green Fiber Bottle is a fully biodegradable bottle made from molded paper pulp.Its development depends on the establishment of the manufacturing technology. Impulse drying, an innovative way of drying, has the potential to improve significantly the manufacturing process of the Green Fiber Bot...... Bottle, towards a sustainable packaging...

  17. 21 CFR 868.5220 - Blow bottle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blow bottle. 868.5220 Section 868.5220 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5220 Blow bottle. (a) Identification. A blow bottle is a device that is intended for medical purposes to induce a forced expiration from a patient. The patient blows...

  18. Students Lobby for Bottle Bill.

    Science.gov (United States)

    Thompson, Nathan H.

    1980-01-01

    Summarizes the 10-year accomplishments of Students for Environmental Quality from Bellport High School, New York, including successful halting of local waste oil pollution, instigating state laws to prohibit seal killing and protect the Carmans River wetlands, and details current efforts to assist in passage of a state "bottle bill."…

  19. From Blogs to Bottle Caps

    Science.gov (United States)

    Edinger, Ted

    2012-01-01

    There is a wonderful community of art educators connecting a once-isolated profession through blogging. Art educators around the world are sharing ideas and communicating with their peers through this amazing resource. In this article, the author describes the bottle cap mural at Tulip Grove Elementary School which was inspired by this exchange of…

  20. MEASURING APPARATUS

    Science.gov (United States)

    Kohman, T.P.; Weissbourd, B.W.

    1959-02-17

    An ion chamber assembly is presented for measuring neutron emission of a relatively slow rate from a radioactive sample. The detecting apparatus comprises a container filled with neutron slowing material and having a cavity where a neutron source may be located centrally in the container. A plurality of ion chamber units are disposed equidistantly from the source and from each other for detecting the neutron radiation. Each of the ion chamber units has an ion chamber and a second chamber of substantially the same diameter as the ion chamber and in end-to-end relationship therewith. The second chamber contains paraffin and an axially disposed lead-in conductor for the ion chamber central electrode. The preamplifier circuit whose input is connected to the lead-in conductor is housed in a third container arranged in end-to-end relationship with the second chamber.

  1. Hydrogenation apparatus

    Science.gov (United States)

    Friedman, Joseph [Encino, CA; Oberg, Carl L [Canoga Park, CA; Russell, Larry H [Agoura, CA

    1981-01-01

    Hydrogenation reaction apparatus comprising a housing having walls which define a reaction zone and conduits for introducing streams of hydrogen and oxygen into the reaction zone, the oxygen being introduced into a central portion of the hydrogen stream to maintain a boundary layer of hydrogen along the walls of the reaction zone. A portion of the hydrogen and all of the oxygen react to produce a heated gas stream having a temperature within the range of from 1100.degree. to 1900.degree. C., while the boundary layer of hydrogen maintains the wall temperature at a substantially lower temperature. The heated gas stream is introduced into a hydrogenation reaction zone and provides the source of heat and hydrogen for a hydrogenation reaction. There also is provided means for quenching the products of the hydrogenation reaction. The present invention is particularly suitable for the hydrogenation of low-value solid carbonaceous materials to provide high yields of more valuable liquid and gaseous products.

  2. Purification apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Mortenson, C.W.

    1982-04-27

    An apparatus is provided for converting sea or other undrinkable waters to drinkable water without the use of driven or moving parts. Reliance upon gradient effects is made to effect the vaporization of, for example, sea water, followed by the condensation of the vapor to form distilled water. Gradient effects are achieved through the provision of differentials in the thermal conductivity, capillary activity, adsorptive, absorptive and/or pressure characteristics of particulate materials, or combinations of such physicals. For example, a column is packed with material graded as to its conductivity, the least thermally conductive material being nearest the cold or ambient water that is to be purified. In packing the column each successive layer of material has a greater thermal conductivity than the layer beneath it with the most conductive being at the top near the outlet arm of the column. The final outlet arm or tube is unheated or is at a temperature lower than that of the topmost conductive material so that vapor reaching the outlet tube gets condensed. This tube leads to a container kept in a cool place as, for example, buried in the ground, as, for instance, at the seashore deep enough to be cooled or to be surrounded by water, thus keeping the condensate cold. Pure water so collected is removed by such means as is desired. Other impure, volatile liquids may be similarly purified.

  3. Simple homemade apparatus for harvesting uncultured magnetotactic microorganisms

    Directory of Open Access Journals (Sweden)

    Lins Ulysses

    2003-01-01

    Full Text Available A simple apparatus for harvesting uncultured magnetotactic microorganisms is described. This apparatus consists of a glass container with two openings. A large opening on the topside is used to introduce the sediment and water. The sediment and water are previously stored in loosely capped bottles previously tested for the presence of magnetotactic bacteria. The apparatus is exposed to a properly aligned magnetic field of a homemade coil and the bacteria are removed through the capillary end of the second opening of the container. Harvested bacteria can then be used to ultrastrucutral studies using electron spectroscopic imaging. Large numbers of magnetotactic bacteria consisting of cocci and rod-shaped cells were efficiently collected from different environments. This apparatus is useful for microbiological studies on uncultured magnetotactic bacteria, especially in molecular approaches for phylogenetic investigations that give information on the natural diversity of microbial communities.

  4. Fixed automated spray technology.

    Science.gov (United States)

    2011-04-19

    This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...

  5. Hair spray poisoning

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002705.htm Hair spray poisoning To use the sharing features on this page, please enable JavaScript. Hair spray poisoning occurs when someone breathes in (inhales) ...

  6. Oxymetazoline Nasal Spray

    Science.gov (United States)

    Oxymetazoline nasal spray is used to relieve nasal discomfort caused by colds, allergies, and hay fever. It ... also used to relieve sinus congestion and pressure. Oxymetazoline nasal spray should not be used to treat ...

  7. Flash radiographic technique applied to fuel injector sprays

    International Nuclear Information System (INIS)

    Vantine, H.C.

    1977-01-01

    A flash radiographic technique, using 50 ns exposure times, was used to study the pattern and density distribution of a fuel injector spray. The experimental apparatus and method are described. An 85 kVp flash x-ray generator, designed and fabricated at the Lawrence Livermore Laboratory, is utilized. Radiographic images, recorded on standard x-ray films, are digitized and computer processed

  8. Development of Syringe/Bottle Hybrids for Sampling Slurries

    International Nuclear Information System (INIS)

    Coleman, C.J.

    1998-01-01

    A convenient and effective sample bottle system based on simple modifications of disposable plastic syringes and bottles has been devised and tested for slurry samples. Syringe/ bottle hybrids (hereafter referred to as syringe bottles) have the convenience of regular flat-bottom bottles with screw cap closures. In addition, the syringe imparts a sliding and adjustable bottom to the bottle that forces the entire contents from the bottle. The system was designed especially to collect samples for high temperature work-ups of DWPF slurry samples. The syringe bottles together with fixed-bottom sample vial inserts would provide the DWPF with convenient and reliable methods for dealing with slurry samples

  9. Page 1 214 G. M. Nabar and C. W. Padmanabhan apparatus used is ...

    Indian Academy of Sciences (India)

    dioxide has been used as the oxidant either in gaseous state or as a solution in carbon tetrachloride, the flask shown in Fig. B, is used. In the prelimi- nary experiments the reaction vessel was a 10 1. bottle with a ground-in- stopper carrying a glass hook for suspending the hank. The apparatus is enclosed in an air ...

  10. How dirty are your reusable water bottles?

    Science.gov (United States)

    Williams, S.

    2017-12-01

    Reusable water bottles are an environment-friendly option but may grow harmful bacteria if not washed regularly. To test whether washing habits affect bacterial growth, I swabbed 10 different plastic reusable bottles and counted colony growth after laboratory incubation. My results did not show a clear relationship between days since last wash and colony growth.

  11. Gas Property Demonstrations Using Plastic Water Bottles

    Science.gov (United States)

    Campbell, Dean J.; Bannon, Stephen J.; Gunter, Molly M.

    2011-01-01

    Plastic water bottles are convenient containers for demonstrations of gas properties illustrating Boyle's law, Charles's law, and Avogadro's law. The contents of iron-based disposable hand warmer packets can be used to remove oxygen gas from the air within an unfilled plastic water bottle.

  12. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  13. 29 CFR 1917.153 - Spray painting (See also § 1917.2, definition of Hazardous cargo, materials, substance, or...

    Science.gov (United States)

    2010-07-01

    ... under construction, major repair or rebuilding of terminal structures, or portable spraying apparatus... flammable vapors, mists or combustible residues, dusts or deposits may be present due to paint spraying... confining and limiting the escape of paint, vapor and residue by means of a powered exhaust system. (3...

  14. 27 CFR 24.308 - Bottled or packed wine record.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottled or packed wine... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Records and Reports § 24.308 Bottled or packed wine record. A proprietor who bottles, packs, or receives bottled or packed beverage wine in bond shall...

  15. 27 CFR 19.383 - Bottling tank gauge.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling tank gauge. 19... Manufacture of Articles Bottling, Packaging, and Removal of Products § 19.383 Bottling tank gauge. When a distilled spirits product is to be bottled or packaged, the proprietor shall gauge the product, on...

  16. 27 CFR 27.208 - Liquor bottles denied entry.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Liquor bottles denied... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor Bottles § 27.208 Liquor bottles denied entry. Filled liquor bottles, not conforming to the...

  17. 27 CFR 27.204 - Distinctive liquor bottles.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Distinctive liquor bottles..., DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor Bottles § 27.204 Distinctive liquor bottles. (a) Application. Liquor bottles of distinctive shape or...

  18. Suitability of Broken Bottles as Fine Aggregate for Production of ...

    African Journals Online (AJOL)

    The use of broken bottles as partial replacement of river sand for production of concrete was investigated. The grading of the broken bottles and sand fell in zone II. The specific gravity of the bottles was 2.55 and that of sand was 2.65. Sand was replaced with the broken bottles in the proportions of 0%, 10%, 20%, 30%, 40%, ...

  19. Helmholtz Resonance in a Water Bottle

    Directory of Open Access Journals (Sweden)

    Annirudh Balachandran

    2011-01-01

    Full Text Available The resonance that occurs when blowing across the top of a water bottle filled with different volumes of water was studied. It was shown that, contrary to popular belief, a water bottle is not an ideal Helmholtz resonator. Resonance in a water bottle with an extendable neck was then studied to determine how the length of the neck affects the resonance. The results showed that ideal Helmholtz resonance occurs when the neck length was in a middle range, while for no neck a standing wave resonance occurs. For a very long neck the results were inconclusive.

  20. Nanosecond and femtosecond mass spectroscopic analysis of a molecular beam produced by the spray-jet technique

    International Nuclear Information System (INIS)

    Yamada, Toshiki; Shinohara, Hidenori; Kamikado, Toshiya; Okuno, Yoshishige; Suzuki, Hitoshi; Mashiko, Shinro; Yokoyama, Shiyoshi

    2008-01-01

    The spray-jet molecular beam apparatus enabled us to produce a molecular beam of non-volatile molecules under high vacuum from a sprayed mist of sample solutions. The apparatus has been used in spectroscopic studies and as a means of molecular beam deposition. We analyzed the molecular beam, consisting of non-volatile, solvent, and carrier-gas molecules, by using femtosecond- and nanosecond- laser mass spectroscopy. The information thus obtained provided insight into the molecular beam produced by the spray-jet technique

  1. Cold spray nozzle design

    Science.gov (United States)

    Haynes, Jeffrey D [Stuart, FL; Sanders, Stuart A [Palm Beach Gardens, FL

    2009-06-09

    A nozzle for use in a cold spray technique is described. The nozzle has a passageway for spraying a powder material, the passageway having a converging section and a diverging section, and at least the diverging section being formed from polybenzimidazole. In one embodiment of the nozzle, the converging section is also formed from polybenzimidazole.

  2. Decontamination apparatus and method

    Science.gov (United States)

    Oakley, David J.

    1987-01-01

    A blast head including a plurality of spray nozzles mounted in a chamber for receiving a workpiece. The several spray nozzles concurrently direct a plurality of streams of a pressurized gas and abrasive grit mixture toward a peripheral portion of the workpiece to remove particulates or debris therefrom. An exhaust outlet is formed in the chamber for discharging the particulates and spent grit.

  3. GLOBEC NEP Rosette Bottle Data (2002)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — GLOBEC (GLOBal Ocean ECosystems Dynamics) NEP (Northeast Pacific) Rosette Bottle Data from New Horizon Cruise (NH0207: 1-19 August 2002). Notes: Physical data...

  4. Spray Rolling Aluminum Strip

    Energy Technology Data Exchange (ETDEWEB)

    Lavernia, E.J.; Delplanque, J-P; McHugh, K.M.

    2006-05-10

    Spray forming is a competitive low-cost alternative to ingot metallurgy for manufacturing ferrous and non-ferrous alloy shapes. It produces materials with a reduced number of processing steps, while maintaining materials properties, with the possibility of near-net-shape manufacturing. However, there are several hurdles to large-scale commercial adoption of spray forming: 1) ensuring strip is consistently flat, 2) eliminating porosity, particularly at the deposit/substrate interface, and 3) improving material yield. Through this program, a new strip/sheet casting process, termed spray rolling, has been developed, which is an innovative manufacturing technique to produce aluminum net-shape products. Spray rolling combines the benefits of twin-roll casting and conventional spray forming, showing a promising potential to overcome the above hurdles associated with spray forming. Spray rolling requires less energy and generates less scrap than conventional processes and, consequently, enables the development of materials with lower environmental impacts in both processing and final products. Spray Rolling was developed as a collaborative project between the University of California-Davis, the Colorado School of Mines, the Idaho National Engineering and Environmental Laboratory, and an industry team. The following objectives of this project were achieved: (1) Demonstration of the feasibility of the spray rolling process at the bench-scale level and evaluation of the materials properties of spray rolled aluminum strip alloys; and (2) Demonstration of 2X scalability of the process and documentation of technical hurdles to further scale up and initiate technology transfer to industry for eventual commercialization of the process.

  5. Radiative Gasification Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This apparatus, developed at EL, determines gasification rate (mass loss rate) of a horizontally oriented specimen exposed in a nitrogen environment to a controlled...

  6. ROLLER FILTRATION APPARATUS

    DEFF Research Database (Denmark)

    2017-01-01

    a medium, comprising a plurality of press rollers, a separation chamber for receiving the medium and defined, in cross section, by the press rollers, and at least one chamber filter located inside and enclosed by the separation chamber. The apparatus is preferably configured such that a negative pressure......The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter and liquid from...

  7. Open globe injuries induced by glass bottles containing carbonated drinks.

    Science.gov (United States)

    Schrader, Wolfgang F; Gramer, Eugen

    2010-03-01

    Reports on open globe injuries caused by exploding bottles containing carbonated drinks have already raised the demand to switch from multi-use glass bottles to plastic bottles. We retrospectively analyzed our files to find out whether this type of injury is limited to multi-use glass bottles, and to what extent carelessness contributed to the injury Among 1,402 open globe injuries that were treated in the departments of ophthalmology at the universities of Freiburg and Würzburg between 1981 and 2004, we retrospectively identified 33 injuries caused by exploding bottles containing carbonated drinks. Patients were excluded from analysis when the destruction of the bottle was intended (destroyed with a hammer, or bottle used as a weapon). The circumstances of the injury, the treatment and the functional outcome was analyzed. 2.4% of all open globe injuries were related to exploding bottles, with a risk of one injury per 1 million inhabitants per year. Ten eyes suffered from a spontaneous explosion of the bottle when it was moved on a shelf or taken out of a box. Eighteen eyes received the injury after the bottle had fallen down and exploded (six of them in children 2 to 8 years). Five bottles exploded during opening of the bottle. In four cases, the bottle cap came off spontaneously and penetrated the eye. Eleven injuries (33%) occurred at work, five of them while moving the bottle and six during breaks at work. Spontaneous explosions in multi-use glass bottles could easily be avoided by changing to plastic bottles; however, exploding single-use glass bottles Containing sparkling wine also contributed to the injuries. In many cases, carelessness was involved. Glass bottles should be never exposed to heat or shaking, and children should never carry glass bottles containing carbonated drinks.

  8. Thermal Arc Spray Overview

    Science.gov (United States)

    Hafiz Abd Malek, Muhamad; Hayati Saad, Nor; Kiyai Abas, Sunhaji; Mohd Shah, Noriyati

    2013-06-01

    Usage of protective coating for corrosion protection was on highly demand during the past decade; and thermal spray coating played a major part during that time. In recent years, the thermal arc spray coating becomes a popular coating. Many big players in oil and gas such as PETRONAS, EXXON MOBIL and SHELL in Malaysia tend to use the coating on steel structure as a corrosion protection. Further developments in coating processes, the devices, and raw materials have led to expansion of functional coatings and applications scope from conventional coating to specialized industries. It is widely used because of its ability to withstand high process temperature, offer advantages in efficiency, lower cost and acts as a corrosion protection. Previous research also indicated that the thermal arc spray offers better coating properties compared to other methods of spray. This paper reviews some critical area of thermal spray coating by discussing the process/parameter of thermal arc spray technology and quality control of coating. Coating performance against corrosion, wear and special characteristic of coating are also described. The field application of arc spray technology are demonstrated and reviewed.

  9. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1981-01-01

    Describes: (1) a variable inductor suitable for an inductance-capacitance bridge consisting of a fixed cylindrical solenoid and a moveable solenoid; (2) long-range apparatus for demonstrating falling bodies; and (3) an apparatus using two lasers to demonstrate ray optics. (SK)

  10. Nuclear core baffling apparatus

    International Nuclear Information System (INIS)

    Cooper, F.W. Jr.; Silverblatt, B.L.; Knight, C.B.; Berringer, R.T.

    1979-01-01

    An apparatus for baffling the flow of reactor coolant fluid into and about the core of a nuclear reactor is described. The apparatus includes a plurality of longitudinally aligned baffle plates with mating surfaces that allow longitudinal growth with temperature increases while alleviating both leakage through the aligned plates and stresses on the components supporting the plates

  11. Flame spray technology method for production of nanopowders

    CERN Document Server

    Trommer, Rafael M

    2015-01-01

    This books presents a complete and updated overview of Flame Spray process, from its History to the Apparatus necessary for the synthesis of nanostructures. It addresses not only the materials produced by this technique, but also their properties, such as crystallinity and crystallite size, specific surface area, particle size and morphology. Also, the principles of nanoparticle formation are described. It is a useful read to all those interested in low cost synthesis of nanostructured powders and coatings.

  12. Fentanyl Nasal Spray

    Science.gov (United States)

    Fentanyl nasal spray is used to treat breakthrough pain (sudden episodes of pain that occur despite round ... effects of the medication) to narcotic pain medications. Fentanyl is in a class of medications called narcotic ( ...

  13. Fentanyl Sublingual Spray

    Science.gov (United States)

    Fentanyl sublingual spray is used to treat breakthrough pain (sudden episodes of pain that occur despite round ... effects of the medication) to narcotic pain medications. Fentanyl is in a class of medications called narcotic ( ...

  14. Dynamics of flare sprays

    International Nuclear Information System (INIS)

    Tandberg-Hanssen, E.; Hansen, R.T.

    1980-01-01

    During solar cycle No. 20 new insight into the flare-spray phenomenon has been attained due to several innovations in solar optical-observing techniques (higher spatial resolution cinema-photography, tunable pass-band filters, multi-slit spectroscopy and extended angular field coronographs). From combined analysis of 13 well-observed sprays which occured between 1969-1974 we conclude that (i) the spray material originates from a preexisting active region filament which undergoes increased absorption some tens of minutes prior to the abrupt chromospheric brightening at the 'flare-start', and (ii) the spray material is confined within a steadily expanding, loop-shaped (presumably magnetically controlled) envelope with part of the material draining back down along one or both legs of the loop. (orig.)

  15. Butorphanol Nasal Spray

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... stop using butorphanol nasal spray, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  16. Beer bottle whistling: a stochastic Hopf bifurcation

    Science.gov (United States)

    Boujo, Edouard; Bourquard, Claire; Xiong, Yuan; Noiray, Nicolas

    2017-11-01

    Blowing in a bottle to produce sound is a popular and yet intriguing entertainment. We reproduce experimentally the common observation that the bottle ``whistles'', i.e. produces a distinct tone, for large enough blowing velocity and over a finite interval of blowing angle. For a given set of parameters, the whistling frequency stays constant over time while the acoustic pressure amplitude fluctuates. Transverse oscillations of the shear layer in the bottle's neck are clearly identified with time-resolved particle image velocimetry (PIV) and proper orthogonal decomposition (POD). To account for these observations, we develop an analytical model of linear acoustic oscillator (the air in the bottle) subject to nonlinear stochastic forcing (the turbulent jet impacting the bottle's neck). We derive a stochastic differential equation and, from the associated Fokker-Planck equation and the measured acoustic pressure signals, we identify the model's parameters with an adjoint optimization technique. Results are further validated experimentally, and allow us to explain (i) the occurrence of whistling in terms of linear instability, and (ii) the amplitude of the limit cycle as a competition between linear growth rate, noise intensity, and nonlinear saturation. E. B. and N. N. acknowledge support by Repower and the ETH Zurich Foundation.

  17. Mirror plasma apparatus

    International Nuclear Information System (INIS)

    Moir, R.W.

    1981-01-01

    A mirror plasma apparatus which utilizes shielding by arc discharge to form a blanket plasma and lithium walls to reduce neutron damage to the wall of the apparatus. An embodiment involves a rotating liquid lithium blanket for a tandem mirror plasma apparatus wherein the first wall of the central mirror cell is made of liquid lithium which is spun with angular velocity great enough to keep the liquid lithium against the first material wall, a blanket plasma preventing the lithium vapor from contaminating the plasma

  18. Determinants of using pacifier and bottle feeding.

    Science.gov (United States)

    Buccini, Gabriela dos Santos; Benício, Maria Helena D'Aquino; Venancio, Sonia Isoyama

    2014-08-01

    To analyze the factors associated with the use of pacifiers and/or bottle feeding in infants aged under one year. This is a cross-sectional study with 34,366 children and using data from the database of the 2nd Nationwide Survey of Breastfeeding Prevalence performed in the Brazilian capitals and Federal District in 2008. Cluster sampling was used. The questionnaire included questions about the use of artificial nipples in the last 24 hours. The analysis considered three outcomes: exclusive use of pacifier, exclusive use of bottle feeding, and use of artificial nipples (pacifier and bottle feeding). Prevalence ratios were obtained using Poisson regression with robust variance following a hierarchical model. The following factors were associated with exclusive use of the pacifier: mother working outside the home, primiparity, child was not breastfed within the first hour, and child had consumed tea on the first day at home. The following factors were associated with exclusive use of bottle feeding: mother working outside the home, primiparity, low birth weight, child not breastfed within the first hour, and child had consumed milk formula and tea on the first day at home. The following factors were associated with use of artificial nipples (pacifier and bottle feeding): mother working outside the home, primiparity, cesarean delivery, the male gender, low birth weight, born in a hospital not accredited as "baby friendly", required health baby monitoring in the Primary Health Care Unit (PR = 0.91), and child had consumed milk formula, water, or tea on the first day at home. This study identified profiles of exclusive users of pacifiers, bottle feeding, and both. The provided information can guide preventive practices for child health.

  19. Determinants of using pacifier and bottle feeding

    Directory of Open Access Journals (Sweden)

    Gabriela dos Santos Buccini

    2014-08-01

    Full Text Available OBJECTIVE To analyze the factors associated with the use of pacifiers and/or bottle feeding in infants aged under one year. METHODS This is a cross-sectional study with 34,366 children and using data from the database of the 2nd Nationwide Survey of Breastfeeding Prevalence performed in the Brazilian capitals and Federal District in 2008. Cluster sampling was used. The questionnaire included questions about the use of artificial nipples in the last 24 hours. The analysis considered three outcomes: exclusive use of pacifier, exclusive use of bottle feeding, and use of artificial nipples (pacifier and bottle feeding. Prevalence ratios were obtained using Poisson regression with robust variance following a hierarchical model. RESULTS The following factors were associated with exclusive use of the pacifier: mother working outside the home, primiparity, child was not breastfed within the first hour, and child had consumed tea on the first day at home. The following factors were associated with exclusive use of bottle feeding: mother working outside the home, primiparity, low birth weight, child not breastfed within the first hour, and child had consumed milk formula and tea on the first day at home. The following factors were associated with use of artificial nipples (pacifier and bottle feeding: mother working outside the home, primiparity, cesarean delivery, the male gender, low birth weight, born in a hospital not accredited as “baby friendly”, required health baby monitoring in the Primary Health Care Unit (PR = 0.91, and child had consumed milk formula, water, or tea on the first day at home. CONCLUSIONS This study identified profiles of exclusive users of pacifiers, bottle feeding, and both. The provided information can guide preventive practices for child health.

  20. factors influencing the consumption and standards of bottled ...

    African Journals Online (AJOL)

    BARTH EKWUEME

    %) of the consumers indicated spending (approximately 9.6%) of their monthly income on bottled water. Nearly all the surveyed companies had no standardized drinking water quality guidelines. Majority of Nairobi residents consume bottled ...

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  3. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  4. Thermal Acoustic Fatigue Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Acoustic Fatigue Apparatus (TAFA) is a progressive wave tube test facility that is used to test structures for dynamic response and sonic fatigue due to...

  5. Light shielding apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Richard Dean; Thom, Robert Anthony

    2017-10-10

    A light shielding apparatus for blocking light from reaching an electronic device, the light shielding apparatus including left and right support assemblies, a cross member, and an opaque shroud. The support assemblies each include primary support structure, a mounting element for removably connecting the apparatus to the electronic device, and a support member depending from the primary support structure for retaining the apparatus in an upright orientation. The cross member couples the left and right support assemblies together and spaces them apart according to the size and shape of the electronic device. The shroud may be removably and adjustably connectable to the left and right support assemblies and configured to take a cylindrical dome shape so as to form a central space covered from above. The opaque shroud prevents light from entering the central space and contacting sensitive elements of the electronic device.

  6. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  7. Apparatus for drying sugar cubes

    NARCIS (Netherlands)

    Derckx, H.A.J.; Torringa, H.M.

    1999-01-01

    Device for drying sugar cubes containing a heating apparatus for heating and dehumidifying the sugar cubes, a conditioning apparatus for cooling off and possibly further dehumidifying the sugar cubes and a conveying apparatus for conveying the sugar cubes through the heating apparatus and the

  8. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  9. Spin coating apparatus

    Science.gov (United States)

    Torczynski, John R.

    2000-01-01

    A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.

  10. Sludge recovery apparatus

    International Nuclear Information System (INIS)

    Marmo, A.R.

    1979-01-01

    An improved design of a sludge recovery apparatus used in the fabrication of nuclear fuel is described. This apparatus provides for automatic separation of sludge from the grinder coolant, drying of the sludge into a flowable powder and transfer of the dry powder to a salvage container. It can be constructed to comply with criticality-safe-geometry requirements and to obviate need for operating personnel in its immediate vicinity. (UK)

  11. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  12. 27 CFR 24.256 - Bottle aging wine.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottle aging wine. 24.256 Section 24.256 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Storage, Treatment and Finishing of Wine Bottling, Packing, and Labeling of Wine § 24.256 Bottle aging wine. Wine...

  13. 27 CFR 24.255 - Bottling or packing wine.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling or packing wine. 24.255 Section 24.255 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Storage, Treatment and Finishing of Wine Bottling, Packing, and Labeling of Wine § 24.255 Bottling or...

  14. Bottle-feeding and the Risk of Pyloric Stenosis

    DEFF Research Database (Denmark)

    Krogh, Camilla; Biggar, Robert J; Fischer, Thea Kølsen

    2012-01-01

    Bottle-feeding has been suggested to increase the risk of pyloric stenosis (PS). However, large population-based studies are needed. We examined the effect of bottle-feeding during the first 4 months after birth, by using detailed data about the timing of first exposure to bottle...

  15. 27 CFR 19.749 - Bottling and packaging record.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottling and packaging record. 19.749 Section 19.749 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... Account § 19.749 Bottling and packaging record. The bottling and packaging record shall be prepared and...

  16. 27 CFR 27.209 - Used liquor bottles.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Used liquor bottles. 27..., DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor Bottles § 27.209 Used liquor bottles. The appropriate TTB officer may pursuant to letterhead application...

  17. 27 CFR 5.46 - Standard liquor bottles.

    Science.gov (United States)

    2010-04-01

    ..., DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF DISTILLED SPIRITS Standards of Fill for... container of a bottle shall not be so designed as to mislead purchasers as to the size of the bottles. (b... after closure. (c) Design. A liquor bottle shall be held (irrespective of the correctness of the stated...

  18. Bisphenol A Detection in Various Brands of Drinking Bottled Water ...

    African Journals Online (AJOL)

    Bisphenol A Detection in Various Brands of Drinking Bottled Water in Riyadh, Saudi Arabia Using Gas Chromatography/Mass Spectrometer. ... amounts of BPA leached from bottle containers into the water. Long storage of bottled water under direct sunlight should be avoided to reduce the risk of human exposure to BPA.

  19. Sea Spray Aerosols

    DEFF Research Database (Denmark)

    Butcher, Andrew Charles

    entrainment may account for the large discrepancy in energy input for the two systems. In the third study, the temperature dependence of sea spray aerosol production is probed with the use of a highly stable temperature controlled plunging jet. Similar to previous studies, particle production increases...... of a cloud condensation nuclei ounter. Proxy solutions with high inorganic salt concentrations and some organics produce sea spray aerosol particles with little change in cloud condensation activity relative to pure salts. Comparison is made between a frit based method for bubble production and a plunging...... a relationship between plunging jet particle ux, oceanic particle ux, and energy dissipation rate in both systems. Previous sea spray aerosol studies dissipate an order of magnitude more energy for the same particle ux production as the open ocean. A scaling factor related to the energy expended in air...

  20. Droplets and sprays

    CERN Document Server

    Sazhin, Sergei

    2014-01-01

    Providing a clear and systematic description of droplets and spray dynamic models, this book maximises reader insight into the underlying physics of the processes involved, outlines the development of new physical and mathematical models, and broadens understanding of interactions between the complex physical processes which take place in sprays. Complementing approaches based on the direct application of computational fluid dynamics (CFD), Droplets and Sprays treats both theoretical and practical aspects of internal combustion engine process such as the direct injection of liquid fuel, subcritical heating and evaporation. Includes case studies that illustrate the approaches relevance to automotive applications,  it is also anticipated that the described models can find use in other areas such as in medicine and environmental science.

  1. [A suction bottle for post-anesthesia evaluation of the distribution of consumed carbon dioxide absorber granules in the canister].

    Science.gov (United States)

    Morioka, Tohru

    2004-11-01

    Anesthetic methods, apparatus, and respiratory care patterns have changed greatly in the past several decades. New scrutiny must be applied to patterns of carbon dioxide absorber consumption in the canisters in anesthesia circuits. Fine examination may be performed by extracting absorber granules by suction to avoid jumbling the granules in the canister. However, a general surgical suction apparatus has too narrow suction tubes, a low flow volume and too large reservoir bottles. We constructed a reservoir bottle of 1.5 l to trap the granules. The bottle is closed with an easily removable lid penetrated by inlet (with a larger diameter) and outlet cannulas. A conventional heat and moisture exchange filter is affixed to the outlet to prevent contamination of the suction system by alkaline absorber dust. Suction may be applied by a vacuum cleaner with a higher flow rate. Traditional recommendation to use baffles along the inside wall of the canister to prevent "channeling of exhaled gases by the wall effect" may turn out to be misleading.

  2. Bottled Water Everywhere: Keeping it Safe

    Science.gov (United States)

    ... water also comes from municipal sources—in other words, the tap. Municipal water is usually treated before it is bottled. Examples ... regulations put in place and enforced by FDA. Water must be sampled, analyzed, and found to be safe and sanitary. These regulations also ...

  3. A Plastic Bottle as Microetcher Hood

    Directory of Open Access Journals (Sweden)

    Narendra Shriram Sharma

    2012-01-01

    Full Text Available Different methods of recycling orthodontic attachments include flaming, grinding, and microetching. Microetching using aluminum oxide particles leads to spillage and inhalation hazards. A simple and economical method is presented using a disposable plastic bottles, which will prevent the spillage and aid in making microetching more ecofriendly.

  4. Sprayed concrete linings

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-12-01

    Sprayed concrete, or shotcrete, was invented in the 1920s for preserving dinosaur skeletons and was used underground initially in coalmines for the preservation and fine proofing of timber supports. Its use as a support lining in rock tunnelling was developed in the 1950s and 60s. The article surveys equipment available from major manufacturers and suppliers of concrete spraying equipment (Aliva, Cifa, GIA, Industri, Ingersoll Rand, etc.), specialist cement and additive manufacturers (Castle, Cement, Moria Carbotech). manufacturers of lattice girders and fibre reinforcement, and manufacturers of instrumentation for tunnel linings. 5 tabs., 9 photos.

  5. Characterization and physical stability of spray dried solid dispersions of probucol and PVP-K30

    DEFF Research Database (Denmark)

    Thybo, Pia; Pedersen, Betty L; Hovgaard, Lars

    2008-01-01

    of small-sized amorphous powders dispersed in a hydrophilic polymer. SDs were prepared by spray drying solutions of probucol and different amounts of PVP-K30. The obtained SDs were characterized by dissolution rate measurements in a flow-through apparatus, X-ray Powder Diffraction (XRPD), Differential...

  6. Fluid-filled bomb-disrupting apparatus and method

    Science.gov (United States)

    Cherry, Christopher R.

    2001-01-01

    An apparatus and method for disarming improvised bombs are disclosed. The apparatus comprises a fluid-filled bottle or container made of plastic or another soft material which contains a fixed or adjustable, preferably sheet explosive. The charge is fired centrally at its apex and can be adjusted to propel a fluid projectile that is broad or narrow, depending upon how it is set up. In one embodiment, the sheet explosive is adjustable so as to correlate the performance of the fluid projectile to the disarming needs for the improvised explosive device (IED). Common materials such as plastic water bottles or larger containers can be used, with the sheet explosive or other explosive material configured in a general chevron-shape to target the projectile toward the target. In another embodiment, a thin disk of metal is conformably mounted with the exterior of the container and radially aligned with the direction of fire of the fluid projectile. Depending on the configuration and the amount of explosive and fluid used, a projectile is fired at the target that has sufficient energy to penetrate rigid enclosures from fairly long stand-off and yet is focused enough to be targeted to specific portions of the IED for disablement.

  7. Improvement of the inlet system for the spray-jet technique for use in spectroscopic studies and molecular deposition

    International Nuclear Information System (INIS)

    Yamada, Toshiki; Shinohara, Hidenori; Mashiko, Shinro

    2006-01-01

    We previously developed a molecular beam apparatus with a spray-jet technique in order to produce a molecular beam of non-volatile molecules in vacuum from the sprayed mist of a sample solution. The apparatus is for use in spectroscopic studies or a means of molecular deposition. The spray-jet inlet system consisted of an ultrasonic nebulizer, an inlet chamber and a pulsed nozzle. In the present paper, further improvements to the spray-jet inlet system are reported. The main improvement is the introduction of a pneumatic nebulizer to replace the previous ultrasonic nebulizer. The efficiency of molecular beam generation was evaluated on the basis of the signal intensity of the resonantly enhanced multiphoton ionization time-of-flight mass (REMPI-TOFMS) spectra for a Rhodamine B/methanol solution and the amount of sample consumed. The introduction of the pneumatic nebulizer increased the efficiency by a factor of 20

  8. Thermal energy test apparatus

    Science.gov (United States)

    Audet, N. F.

    1991-10-01

    The Navy Clothing and Textile Research Facility (NCTRF) designed and fabricated a thermal energy test apparatus to permit evaluation of the heat protection provided by crash crew firefighter's proximity clothing materials against radiant and convective heat loads, similar to those found outside the flame zone of aircraft fuel fires. The apparatus employs electrically operated quartz lamp radiant heaters and a hot air convective heater assembly to produce the heat load conditions the materials to be subjected to, and is equipped with heat flux sensors of different sensitivities to measure the incident heat flux on the sample material as well as the heat flux transmitted by the sample. Tests of the apparatus have shown that it can produce radiant heat flux levels equivalent to those estimated to be possible in close proximity to large aircraft fuel fires, and can produce convective heat fluxes equivalent to those measured in close proximity to aircraft fuel fires at upwind and sidewind locations. Work was performed in 1974.

  9. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Palermo, A.; Zupancic, A.

    1981-01-01

    A computed tomography (CT) scanner apparatus including improved arrangement for transferring high voltage electrical energy between a stationary gantry and a rotating assembly is described. The assembly carries the X-ray source and has an opening defining an aperture to receive a part of a patient. A first axis about which the assembly rotates, passes through the aperture. The apparatus includes a number of slip rings which are used for effecting the transfer of the electrical energy. Respective portions of the gantry and rotating assembly define a cavity which contains an insulating di-electric fluid in which the slip rings are immersed. The apparatus is of compact design and, further, the rotating assembly and the slip rings can be tilted about a second axis which intersects the first axis. (author)

  10. Pore roller filtration apparatus

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter from a medium, comp...... of a pore roller and one other roller, means for establishing a pressure difference across the filter, means for passing filter and filter cake through the set of rollers, and a closure mechanism configured to control the transverse tension between the rollers......., comprising a pressure regulated separation chamber defined, in cross section, by a plurality of rollers mounted between opposing sidewalls, each of said rollers having a shaft adapted to be engaged with the sidewalls, a filter arranged so that it passes between at least one set of said rollers consisting...

  11. Electroplating method and apparatus

    International Nuclear Information System (INIS)

    Looney, R.B.; Smith, W.E.L.

    1978-01-01

    Disclosed is an apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm

  12. Ultrasonic drilling apparatus

    Science.gov (United States)

    Duran, E.L.; Lundin, R.L.

    1988-06-20

    Apparatus attachable to an ultrasonic drilling machine for drilling deep holes in very hard materials, such as boron carbide, is provided. The apparatus utilizes a hollow spindle attached to the output horn of the ultrasonic drilling machine. The spindle has a hollow drill bit attached at the opposite end. A housing surrounds the spindle, forming a cavity for holding slurry. In operation, slurry is provided into the housing, and into the spindle through inlets while the spindle is rotating and ultrasonically reciprocating. Slurry flows through the spindle and through the hollow drill bit to cleanse the cutting edge of the bit during a drilling operation. 3 figs.

  13. Thermal spray for commercial shipbuilding

    Science.gov (United States)

    Rogers, F. S.

    1997-09-01

    Thermal spraying of steel with aluminum to protect it from corrosion is a technology that has been proven to work in the marine environment. The thermal spray coating system includes a paint sealer that is applied over the thermally sprayed aluminum. This extends the service life of the coating and provides color to the end product. The thermal spray system protects steel both through the principle of isolation (as in painting) and galvanizing. With this dual protection mechanism, steel is protected from corrosion even when the coating is damaged. The thermal- sprayed aluminum coating system has proved the most cost- effective corrosion protection system for the marine environment. Until recently, however, the initial cost of application has limited its use for general application. Arc spray technology has reduced the application cost of thermal spraying of aluminum to below that of painting. Commercial shipbuilders could use this technology to enhance their market position in the marine industry.

  14. Improved Orifice Plate for Spray Gun

    Science.gov (United States)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  15. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  16. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1979-01-01

    Six different pieces of physics apparatus are described: Telsa Coil for instant ignition of sodium arc lamps, Timekube, Magnetic Maps of the United States, a slinky with vertical mounting, a wave generator power supply, and a long-period timer power switch. Price and supplier are included. (BT)

  17. communication method and apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    The present invention relates to a non-lingual communication method and apparatus, wherein a physical or physiological signal consciously created by a first subject (1) is detected and converted into a transmitted output signal presented to a second subject (7) in order to communicate information...

  18. Electrolysis apparatus and method

    International Nuclear Information System (INIS)

    1975-01-01

    A procedure in which electrolysis is combined with radiolysis to improve the reaction yield is proposed for the production of hydrogen and oxygen from water. An apparatus for this procedure is disclosed. High-energy electric pulses are applied between the anode and kathode of an electrolytical cell in such a way that short-wave electromagnetic radiation is generated at the same time

  19. Mobile lighting apparatus

    Science.gov (United States)

    Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

    2013-05-14

    A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

  20. Pump apparatus including deconsolidator

    Energy Technology Data Exchange (ETDEWEB)

    Sonwane, Chandrashekhar; Saunders, Timothy; Fitzsimmons, Mark Andrew

    2014-10-07

    A pump apparatus includes a particulate pump that defines a passage that extends from an inlet to an outlet. A duct is in flow communication with the outlet. The duct includes a deconsolidator configured to fragment particle agglomerates received from the passage.

  1. Building scientific apparatus

    National Research Council Canada - National Science Library

    Moore, John H; Davis, Christopher C; Coplan, Michael A; Greer, Sandra C

    2009-01-01

    ... specification of the components of apparatus, many new to this edition. Data on the properties of materials and components used by manufacturers are included. Mechanical, optical, and electronic construction techniques carried out in the laboratory, as well as those let out to specialized shops, are also described. Step-by-step instruc...

  2. Kaleidoscope – Printed Textiles by Neil Bottle

    OpenAIRE

    Bottle, Neil

    2013-01-01

    One man show at Rochester Art Gallery. In the Kaleidoscope series, Neil Bottle explores the relationship between digital textile printing and craft printing techniques and how these seemingly opposing practices can coexist. A combination of the latest cutting-edge digital print techniques such as dye sublimation combined with craft traditions such as screen printing, discharge printing, pleating and shibori have been developed in the work. The Kaleidoscope series of wallhangings is pr...

  3. Recall campaign for gas bottles and banks

    CERN Multimedia

    2015-01-01

    The previous contract with gas supplier Carbagas ended on 31 March 2015. Gas bottles and banks are not a property of CERN. According to the contract terms, they can remain on CERN sites without any extra costs until 30 September 2015.    If you are using Carbagas containers (bottles and/or banks) for gas purchased between 1 April 2010 and 31 March 2015, multiple options exist: Return them to the closest gas point. Purchase them on the following basis:     Rent them on the following basis: 12 CHF/month for bottles, 144 CHF/month for banks. The recall campaign has been going on for several months already: we would like to thank everyone who has already replied to it. If you haven’t answered yet, there is still time. If you know of unused or abandoned Carbagas containers, please don’t hesitate to contact us. Thank you i...

  4. Sea Spray Aerosols

    DEFF Research Database (Denmark)

    Butcher, Andrew Charles

    emissions produced directly from bubble bursting as the result of air entrainment from breaking waves and particles generated from secondary emissions of volatile organic compounds. In the first paper, we study the chemical properties of particles produced from several sea water proxies with the use...... of a cloud condensation nuclei ounter. Proxy solutions with high inorganic salt concentrations and some organics produce sea spray aerosol particles with little change in cloud condensation activity relative to pure salts. Comparison is made between a frit based method for bubble production and a plunging...... a relationship between plunging jet particle ux, oceanic particle ux, and energy dissipation rate in both systems. Previous sea spray aerosol studies dissipate an order of magnitude more energy for the same particle ux production as the open ocean. A scaling factor related to the energy expended in air...

  5. Flame spraying of polymers

    International Nuclear Information System (INIS)

    Varacalle, D.J. Jr.; Zeek, D.P.; Couch, K.W.; Benson, D.M.; Kirk, S.M.

    1997-01-01

    Statistical design-of-experiment studies of the thermal spraying of polymer powders are presented. Studies of the subsonic combustion (i.e., Flame) process were conducted in order to determine the quality and economics of polyester and urethane coatings. Thermally sprayed polymer coatings are of interest to several industries for anticorrosion applications, including the chemical, automotive, and aircraft industries. In this study, the coating design has been optimized for a site-specific application using Taguchi-type fractional-factorial experiments. Optimized coating designs are presented for the two powder systems. A substantial range of thermal processing conditions and their effect on the resultant polymer coatings is presented. The coatings were characterized by optical metallography, hardness testing, tensile testing, and compositional analysis. Characterization of the coatings yielded the thickness, bond strength, Knoop microhardness, roughness, deposition efficiency, and porosity. Confirmation testing was accomplished to verify the coating designs

  6. Numerical modelling of fuel sprays

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, C.

    1999-06-01

    The way the fuel is introduced into the combustion chamber is one of the most important parameters for the power output and the generation of emissions in the combustion of liquid fuels. The interaction between the turbulent gas flow field and the liquid fuel droplets, the vaporisation of them and the mixing of the gaseous fuel with the ambient air that are vital parameters in the combustion process. The use of numerical calculations is an important tool to better understand these complex interacting phenomena. This thesis reports on the numerical modelling of fuel sprays in non-reacting cases using an own developed spray module. The spray module uses the stochastic parcel method to represent the spray. The module was made in such manner that it could by coupled with different gas flow solver. Results obtained from four different gas flow solvers are presented in the thesis, including the use of two different kinds of turbulence models. In the first part the spray module is coupled with a k-{eta} based 2-D cylindrical gas flow solver. A thorough sensitivity analysis was performed on the spray and gas flow solver parameters, such as grid size dependence and sensitivity to initial values of k-{eta}. The results of the spray module were also compared to results from other spray codes, e.g. the well known KIVA code. In the second part of this thesis the spray was injected into a turbulent and fully developed crossflow studied. The spray module was attached to a LES (Large Eddy Simulation) based flow solvers enabling the study of the complex structures and time dependent phenomena involved in spray in crossflows. It was found that the spray performs an oscillatory motion and that the Strouhal number in the wake was about 0.1. Different spray breakup models were evaluated by comparing with experimental results 66 refs, 56 figs

  7. Kelvin spray ionization.

    Science.gov (United States)

    Özdemir, Abdil; Lin, Jung-Lee; Gillig, Kent J; Chen, Chung-Hsuan

    2013-11-21

    A novel self-powered dual spray ionization source has been developed for applications in mass spectrometry. This new source does not use any power supply and produces both positive and negative ions simultaneously. The idea behind this ionization source comes from the Kelvin water dropper. The source employs one or two syringes, two pneumatic sprays operated over a range of flow rates (0.15-15 μL min(-1)) and gas pressures (0-150 psi), and two double layered metal screens for ion formation. A variable electrostatic potential from 0 to 4 kV can be produced depending on solvent and gas flow rates that allow gentle ionization of compounds. There are several parameters that affect the performance during ionization of molecules including the flow rate of solvent, gas pressure, solvent acidity, position of spray and metal screens with respect to each other and distance between metal screens and the counter electrode. This ionization method has been successfully applied to solutions of peptides, proteins and non-covalent complexes. In comparison with ESI, the charge number of the most populated state is lower than that from ESI. It indicates that this is a softer ionization technique and it produces more protein ions with folded structures. The unique features of Kelvin spray ionization (KeSI) are that the method is self-powered and ionization occurs at very low potentials by providing very low internal energy to the ions. This advantage can be used for the ionization of very fragile molecules and investigation of non-covalent interactions.

  8. 21 CFR 880.6085 - Hot/cold water bottle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hot/cold water bottle. 880.6085 Section 880.6085... Devices § 880.6085 Hot/cold water bottle. (a) Identification. A hot/cold water bottle is a device intended for medical purposes that is in the form of a container intended to be filled with hot or cold water...

  9. Flexural Toughness of Ring-Shaped Waste Bottle Fiber Concrete

    OpenAIRE

    Faisal S. K.; Irwan J. M.; Othman N.; Wan Ibrahim M. H

    2016-01-01

    Polyethylene terephthalate (PET) bottles are plastic containers that are typically discarded, and thus, cause environmental pollution. To solve this problem, PET bottles are recycled incorporating with concrete. A ring-shaped PET (RPET) fiber are introduced in this study and designed with a special shape to mobilize fiber yielding rather than fiber pullout. Therefore, aim of this paper is to investigate the influence of RPET bottles fibre in terms of toughness strength. The width of RPET fibe...

  10. [Head injuries caused by beer glasses and bottles].

    Science.gov (United States)

    Hottmar, P; Havel, R

    1991-06-01

    The authors investigated head injuries in 23 subjects caused by beer glasses and bottles, differentiating thin-walled and thick-walled glasses, full and empty bottles and whether the injury was caused by hitting with the bottle or throwing it. A large range of injuries was found--from trivial ones to serious health damage. From the character of the injury the injuring object cannot be assessed.

  11. New alternatives in construction: earth filled pet bottles

    OpenAIRE

    Ruiz Valencia, Daniel; Pontificia Universidad Javeriana; López Pérez, Cecilia;; Cortes, Eliana; Pontificia Universidad Javeriana; Froese, Andreas; Pontificia Universidad Javeriana

    2014-01-01

    ABSTRACTTwo of the main problems of mankind are the lack of housing and the accumulation of solid waste and garbage thatultimately brings environmental problems. Within this solid waste are plastics such as the PET bottles (for examplesoda bottles). In order to try to solve both problems, since 2001 Eco-Tec Soluciones has pioneered in the constructionof houses and water storage structures with PET bottles filled with rammed earth. Groups GRIME and Estructuras yConstrucción of the Pontificia U...

  12. Improvements in measuring apparatus

    International Nuclear Information System (INIS)

    Casey, W.

    1976-01-01

    Measuring apparatus is described that is suitable for gauging the wall profiles of downwardly extending channels in nuclear reactors, but which is equally applicable to channels such as pipe bores and conduits in other types of plant. The apparatus comprises a probe carrying a measuring transducer giving an electrical output. The probe support may be moved stepwise along the channel along a track between end members. An electrical conductor is provided for transmitting the electrical output of the transducer to an indicator located remote from the probe. The probe support may consist of a cable attached at one end to a winding drum, and incorporating an electrical conductor connected to the transducer. Channel engaging means are provided on the probe that permits free upward movement of the probe when the latter is suspended by the cable and moves into gripping engagement with the channel wall when the tension in the cable is relaxed. (U.K.)

  13. Portable shower apparatus

    Science.gov (United States)

    Grenier, Francis E. (Inventor)

    1993-01-01

    A multipurpose, collapsible, shower apparatus for use almost anywhere but especially adapted for use in places somewhat remote from civilization such as recreational vehicles, campers, the outdoors, space vehicles and the like where there may be a limited amount of water or other liquid. The collapsible shower apparatus includes a curtain assembly having an inner wall, an outer wall and a porous element for separating the inner and outer walls; a series of spaced hollow hoops connected by one or more sets of hollow tubes (manifolds); one or more nozzles connected to and in communication with at least one of the hollow hoops; a source of fluid under pressure in communication with at least one of the hollow hoops; and a suction pump for withdrawing fluid from the interior of the curtain assembly.

  14. Radiation guard apparatus

    International Nuclear Information System (INIS)

    Collica, C.; Epifano, L.; Farella, R.

    1976-01-01

    Radiation shielding apparatus for use in conjunction with a pad on a table. The apparatus comprises a set of units, each unit comprising a pair of joined substantially flat orthogonal flaps. The flaps are formed of a radiation shielding material and are adapted for removable placement under the pad whereby one flap contacts the table and the other flap extends vertically from an edge thereof. In a preferred embodiment of the invention the set consists of five units that provide protection around three sides of a rectangular table. In this embodiment, two of the units are identical and have asymmetrical trapezoidal flaps, and two others of the units are also identical, but have trapezoidal flaps which are of reversed orientation with respect to the first-mentioned two units. 6 claims, 4 drawing figures

  15. Apparatus for obtaining radiographs

    International Nuclear Information System (INIS)

    Frank, L.F.

    1977-01-01

    An apparatus for making x-ray pictures by imagewise exposing a cloud chamber containing a high atomic number gas mixed with a condensate vapor is described. The gas is under sufficiently high pressure to assure substantially complete absorption of the incident x-rays. Optical means are provided so that visible x-ray tracks are viewed from a direction aligned with the tracks

  16. Automatic temperature adjustment apparatus

    Science.gov (United States)

    Chaplin, James E.

    1985-01-01

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  17. Wave disc engine apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Norbert; Piechna, Janusz; Sun, Guangwei; Parraga, Pablo-Francisco

    2018-01-02

    A wave disc engine apparatus is provided. A further aspect employs a constricted nozzle in a wave rotor channel. A further aspect provides a sharp bend between an inlet and an outlet in a fluid pathway of a wave rotor, with the bend being spaced away from a peripheral edge of the wave rotor. A radial wave rotor for generating electricity in an automotive vehicle is disclosed in yet another aspect.

  18. Multicusp plasma containment apparatus

    International Nuclear Information System (INIS)

    Limpaecher, R.

    1980-01-01

    It has been discovered that plasma containment by a chamber having multi-pole magnetic cusp reflecting walls in combination with electronic injection for electrostatic containment provides the means for generating magnetic field free quiescent plasmas for practical application in ion-pumps, electronic switches, and the like. 1250 ''alnico v'' magnets 1/2 '' X 1/2 '' X 1 1/2 '' provide containment in one embodiment. Electromagnets embodying toroidal funneling extend the principle to fusion apparatus

  19. Medical radiological apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    With the apparatus described, images can be obtained by rotation scanning and the image formation from a three dimensional image matrix is converted into an overall picture. Detectors for both X-ray radiation and γ radiation are present and these consist of a row of detector elements, from each of which a separate read-out can be obtained. Therefore both X-ray and γ ray images emitted from the examined object can be obtained. (Th.P.)

  20. Pyrolysis process and apparatus

    Science.gov (United States)

    Lee, Chang-Kuei

    1983-01-01

    This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.

  1. Vortex Apparatus and Demonstrations

    Science.gov (United States)

    Shakerin, Said

    2010-05-01

    Vortex flow, from millimeter to kilometer in scale, is important in many scientific and technological areas. Examples are seen in water strider locomotion, from industrial pipe flow (wastewater treatment) to air traffic control (safe distance between aircrafts on a runway ready for takeoff) to atmospheric studies.2-5 In this paper, we focus on a particular vortex known as bathtub vortex (BTV). It occurs when water is drained from a hole at the bottom of a container such as a bathtub or a sink under the action of gravity. The vortex has a funnel shape with a central air core, resembling a tornado. We have designed a portable apparatus to demonstrate bathtub vortex on a continual basis. The apparatus consists of a clear cylinder supported by a frame over a water reservoir and a submersible pump. Young and old have been equally amazed by watching the demonstrations at various public presentations held at the University of the Pacific recently. With material cost of less than 100, the apparatus can be easily fabricated and used at other universities. With a short set-up time, it is an ideal device for promoting science to the general public, and it can be used to enhance lectures in physics courses as well.

  2. Warm spraying-a novel coating process based on high-velocity impact of solid particles.

    Science.gov (United States)

    Kuroda, Seiji; Kawakita, Jin; Watanabe, Makoto; Katanoda, Hiroshi

    2008-07-01

    In recent years, coating processes based on the impact of high-velocity solid particles such as cold spraying and aerosol deposition have been developed and attracting much industrial attention. A novel coating process called 'warm spraying' has been developed, in which coatings are formed by the high-velocity impact of solid powder particles heated to appropriate temperatures below the melting point of the powder material. The advantages of such process are as follows: (1) the critical velocity needed to form a coating can be significantly lowered by heating, (2) the degradation of feedstock powder such as oxidation can be significantly controlled compared with conventional thermal spraying where powder is molten, and (3) various coating structures can be realized from porous to dense ones by controlling the temperature and velocity of the particles. The principles and characteristics of this new process are discussed in light of other existing spray processes such as high-velocity oxy-fuel spraying and cold spraying. The gas dynamics of particle heating and acceleration by the spraying apparatus as well as the high-velocity impact phenomena of powder particles are discussed in detail. Several examples of depositing heat sensitive materials such as titanium, metallic glass, WC-Co cermet and polymers are described with potential industrial applications.

  3. Towards a sensory congruent beer bottle: Consumer associations between beer brands, flavours, and bottle designs

    NARCIS (Netherlands)

    Fenko, Anna; Heiltjes, Sanne; van den Berg-Weitzel, Lianne; Lloyd, Peter; Bohemia, Erik

    2016-01-01

    Sensory packaging design congruent with product and brand characteristics may be used as an innovative tool to communicate product and brand values to consumers and to enhance taste experience. This study investigated whether consumers associate sensory properties of beer bottles with certain brand

  4. Treatment of nursing bottle caries with ribbond

    Directory of Open Access Journals (Sweden)

    Ritu Jindal

    2013-01-01

    Full Text Available Ribbond is a biocompatible, esthetic material made from high-strength polyethylene fiber. Lenowoven polyethylene ribbon (Ribbond has been used successfully for tooth splinting, replacement of missing teeth, reinforcement of provisional acrylic resin fixed partial dentures, and orthodontic retention. This article presents the application of this polyethylene ribbon - RIBBOND - for the treatment of nursing bottle caries. To conclude we suggest that this combined technique of polyethylene fibers and composite material could be a very efficient alternative procedure to conventional treatment plans in pedodontic practice, with excellent esthetics and functional results.

  5. Microplasma sprayed hydroxyapatite coatings

    CERN Document Server

    Dey, Arjun

    2015-01-01

    ""This unique book on development of microplasma sprayed HAp coating has been organized in a very compact yet comprehensive manner. This book also highlights the horizons of future research that invites the attention of global community, particularly those in bio-medical materials and bio-medical engineering field. This book will surely act as a very useful reference material for both graduate/post-graduate students and researchers in the field of biomedical, orthopedic and manufacturing engineering and research. I truly believ that this is the first ever effort which covers almost all the

  6. Apparatus and processes for the mass production of photovoltaic modules

    Science.gov (United States)

    Barth, Kurt L [Ft. Collins, CO; Enzenroth, Robert A [Fort Collins, CO; Sampath, Walajabad S [Fort Collins, CO

    2007-05-22

    An apparatus and processes for large scale inline manufacturing of CdTe photovoltaic modules in which all steps, including rapid substrate heating, deposition of CdS, deposition of CdTe, CdCl.sub.2 treatment, and ohmic contact formation, are performed within a single vacuum boundary at modest vacuum pressures. A p+ ohmic contact region is formed by subliming a metal salt onto the CdTe layer. A back electrode is formed by way of a low cost spray process, and module scribing is performed by means of abrasive blasting or mechanical brushing through a mask. The vacuum process apparatus facilitates selective heating of substrates and films, exposure of substrates and films to vapor with minimal vapor leakage, deposition of thin films onto a substrate, and stripping thin films from a substrate. A substrate transport apparatus permits the movement of substrates into and out of vacuum during the thin film deposition processes, while preventing the collection of coatings on the substrate transport apparatus itself.

  7. Apparatus and processes for the mass production of photovotaic modules

    Science.gov (United States)

    Barth, Kurt L.; Enzenroth, Robert A.; Sampath, Walajabad S.

    2002-07-23

    An apparatus and processes for large scale inline manufacturing of CdTe photovoltaic modules in which all steps, including rapid substrate heating, deposition of CdS, deposition of CdTe, CdCl.sub.2 treatment, and ohmic contact formation, are performed within a single vacuum boundary at modest vacuum pressures. A p+ ohmic contact region is formed by subliming a metal salt onto the CdTe layer. A back electrode is formed by way of a low cost spray process, and module scribing is performed by means of abrasive blasting or mechanical brushing through a mask. The vacuum process apparatus facilitates selective heating of substrates and films, exposure of substrates and films to vapor with minimal vapor leakage, deposition of thin films onto a substrate, and stripping thin films from a substrate. A substrate transport apparatus permits the movement of substrates into and out of vacuum during the thin film deposition processes, while preventing the collection of coatings on the substrate transport apparatus itself.

  8. Quality characteristics of commercial bottled water sold in Owerri ...

    African Journals Online (AJOL)

    The quality characteristics of commercial bottled water sold in Owerri, Imo State, Nigeria were investigated to determine their physical, chemical and bacteriological content. The four brands of bottled water investigated were Mevok ®, Ozonized April ®, Lacrystal ® and Eva ®. The mean turbidity value of all the samples were ...

  9. Labeling practices of water bottling firms and its public health ...

    African Journals Online (AJOL)

    unhcc

    Background: Bottled water labels enable the consumers to choose brands that can best fit to their needs and preferences. ... Methods: Samples of 11 domestic bottled water brands (N = 165) were randomly purchased from retail stores and supermarkets in .... magnesium), trace elements (cadmium, chromium, copper, lead ...

  10. levels of formaldehyde and acetaldehyde in selected bottled ...

    African Journals Online (AJOL)

    Accer

    ABSTRACT. The levels of formaldehyde and acetaldehyde in bottled drinking water and the effect of storage time and storage conditions on their levels were determined. A total of 144 samples of six brands of bottled drinking water were purchased from Dar es Salaam, Iringa, Mwanza and Arusha regions in Tanzania.

  11. Heat Transfer in Glass, Aluminum, and Plastic Beverage Bottles

    Science.gov (United States)

    Clark, William M.; Shevlin, Ryan C.; Soffen, Tanya S.

    2010-01-01

    This paper addresses a controversy regarding the effect of bottle material on the thermal performance of beverage bottles. Experiments and calculations that verify or refute advertising claims and represent an interesting way to teach heat transfer fundamentals are described. Heat transfer coefficients and the resistance to heat transfer offered…

  12. "Bottled or Tap?" A Controversy for Science, Economics, and Society

    Science.gov (United States)

    Lapham, Steven S.

    2009-01-01

    Every year, Americans spend billions of dollars on bottled water. They purchase a bottle from the vending machine or buy a case at the grocery, no longer considering the water that's freely available from their taps. As consumers and as citizens, however, Americans should pause to study the personal and public consequences of this choice. In this…

  13. Aschroft Pressure Switch - Monitor for Low SCHe Supply Bottle Pressure

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    These pressure switches are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. The switches monitor the SCHe supply bottle pressure and are set to alarm at 2200 psig. There is one switch for each SCHe supply (4). Electronic output signal is NON-SAFETY (GS)

  14. Quality assessment of sachet and bottled water sold in Gboko ...

    African Journals Online (AJOL)

    The quality of selected sachet and bottled water produced and sold within Gboko town, Benue State was investigated to determine their Shelf life. Eight brands of sachet water and four brands of bottled water samples were collected from different manufacturers within 24 hours and stored at ambient temperature.

  15. Comparative assessment of physico-chemical quality of bottled and ...

    African Journals Online (AJOL)

    Samples of various brands of bottled water sold in Dar es Salaam, Tanzania were analyzed for physicochemical water quality parameters. For comparison purposes, tap water was similarly examined. The results showed great variations in physico-chemical quality of bottled water, with some samples exceeding the ...

  16. Techno-economic packaging of palm wine preservation and bottling ...

    African Journals Online (AJOL)

    The study was carried out to investigate the economic viability of setting up a small scale palm wine bottling factory with a view to providing investment data to guide entrepreneurs in making investment decisions. The economic evaluation was based on a factory capacity of 750,000 bottles (60cl) per annum with production ...

  17. Labeling practices of water bottling firms and its public health ...

    African Journals Online (AJOL)

    Background: Bottled water labels enable the consumers to choose brands that can best fit to their needs and preferences. Anything inaccurate, however, may pose serious public health risks, especially to vulnerable individuals. In Ethiopia, regular monitoring of bottled water quality and labelling practices is still lacking.

  18. Levels of formaldehyde and acetaldehyde in selected bottled ...

    African Journals Online (AJOL)

    The levels of formaldehyde and acetaldehyde in bottled drinking water and the effect of storage time and storage conditions on their levels were determined. A total of 144 samples of six brands of bottled drinking water were purchased from Dar es Salaam, Iringa, Mwanza and Arusha regions in Tanzania. Analysis was ...

  19. quality assessment of sachet and bottled water soldin gboko, benue

    African Journals Online (AJOL)

    HOD

    The quality of selected sachet and bottled water produced and sold within Gboko town, Benue State was investigated to determine their Shelf life. Eight brands of sachet water and four brands of bottled water samples were collected from different manufacturers within 24 hours and stored at ambient temperature.

  20. Bottled or tap? Testing perceptions about water in Lebanon and ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-06-09

    Jun 9, 2016 ... Researchers compared water quality available in two informal settlements in Lebanon and Jordan. Tests were conducted to compare water supplied by the municipality and bottled water. The results: tests showed that their quality is similar, although the brand of the bottled water and how it is stored affected ...

  1. 27 CFR 27.206 - Bottles not constituting approved containers.

    Science.gov (United States)

    2010-04-01

    ... approved containers. 27.206 Section 27.206 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor Bottles § 27.206 Bottles not constituting approved containers. The appropriate TTB...

  2. 27 CFR 25.158 - Tax computation for bottled beer.

    Science.gov (United States)

    2010-04-01

    ... liters 1 0.04261 (c) For other case sizes. If beer is to be removed in cases or bottles of sizes other... bottled beer. 25.158 Section 25.158 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.158 Tax...

  3. Bacteriological quality of bottled water sold on the Ghanaian market ...

    African Journals Online (AJOL)

    Consumption of bottled water is increasing rapidly in developing countries especially among the middle and high income earners as it is generally perceived to be pure, clean and of good quality. This has led to the sale of different brands of bottled water on the Ghanaian market. Although disease outbreaks due to ...

  4. Genetic diversity of bottle gourd ( Lagenaria siceraria (Molina) Standl.)

    African Journals Online (AJOL)

    Bottle gourd (Lagenaria siceraria (Molina) Standl.) is an important crop in rural communities in South Africa but it remains under-researched. The objective of this study was to assess the genetic diversity present amongst bottle gourd landraces grown by smallholder farmers in South Africa using morphological traits and 11 ...

  5. Improvements to the Whoosh Bottle Rocket Car Demonstration

    Science.gov (United States)

    Campbell, Dean J.; Staiger, Felicia A.; Jujjavarapu, Chaitanya N.

    2015-01-01

    The whoosh bottle rocket car has been redesigned to be more reusable and more robust, making it even easier to use as a demonstration. Enhancements of this demonstration, including the use of heat sensitive ink and electronic temperature probes, enable users to find warmer and cooler regions on the surface of the whoosh bottle.

  6. Characteristics of intermittent fuel sprays

    Science.gov (United States)

    Jawad, B.; Gulari, E.; Henein, N. A.

    1992-03-01

    The spray-tip penetrations and the drop sizes of intermittent fuel sprays were measured by using a modified pulsed optical spray sizer. The average spray tip speeds were determined from simultaneously recorded needle lift signals and obscuration traces. The speeds of a sequence of fuel pulses injected at about 1000 Hz were analyzed to elucidate penetration mechanisms. A correlation that relates penetration distance to time, pressure drop across the nozzle, fuel density, and ambient gas density was obtained. The temporal variations of drop size in penetrating pulses of sprays were measured. The concentration of drops were calculated by combining drop size and obscuration data. The Sauter mean diameter of penetrating fuel drops increased with an increase of the chamber pressure and decreased with an increase of the injection pressure.

  7. Informationization nuclear apparatus communication technique

    International Nuclear Information System (INIS)

    Yu Tiqi; Fang Zongliang; Wen Qilin

    2006-01-01

    The paper explains the request of communication ability in nuclear technique application area. Based on the actuality of nuclear apparatus communication ability, and mainly combining with the development of communication technique, the authors analyzes the application trend of communication technique applying in nuclear apparatus, for the apparatus and system needing communication ability, they need selecting suitable communication means to make them accomplish the task immediately and effectively. (authors)

  8. Pellet inspection apparatus

    Science.gov (United States)

    Wilks, Robert S.; Taleff, Alexander; Sturges, Jr., Robert H.

    1982-01-01

    Apparatus for inspecting nuclear fuel pellets in a sealed container for diameter, flaws, length and weight. The apparatus includes, in an array, a pellet pick-up station, four pellet inspection stations and a pellet sorting station. The pellets are delivered one at a time to the pick-up station by a vibrating bowl through a vibrating linear conveyor. Grippers each associated with a successive pair of the stations are reciprocable together to pick up a pellet at the upstream station of each pair and to deposit the pellet at the corresponding downstream station. The gripper jaws are opened selectively depending on the state of the pellets at the stations and the particular cycle in which the apparatus is operating. Inspection for diameter, flaws and length is effected in each case by a laser beam projected on the pellets by a precise optical system while each pellet is rotated by rollers. Each laser and its optical system are mounted in a container which is free standing on a precise surface and is provided with locating buttons which engage locating holes in the surface so that each laser and its optical system is precisely set. The roller stands are likewise free standing and are similarly precisely positioned. The diameter optical system projects a thin beam of light which scans across the top of each pellet and is projected on a diode array. The fl GOVERNMENT CONTRACT CLAUSE The invention herein described was made in the course of or under a contract or subcontract thereunder with the Department of Energy bearing No. EY-67-14-C-2170.

  9. New liquid-liquid extraction apparatus, 'emulsion-flow' extractor

    International Nuclear Information System (INIS)

    Naganawa, Hirochika

    2017-01-01

    A new liquid-liquid extraction method, called the 'emulsion-flow' method, has recently been developed at Japan Atomic Energy Agency (JAEA). The emulsion-flow method, where low cost, simplicity, high efficiency, compactness, safety, and eco-friendly go together, has attracted attention, and has been expected to bring innovation to liquid-liquid extraction technologies. An apparatus based on the emulsion-flow method can actualize very efficient liquid-liquid extraction with its high two-phase mixing ability to an emulsion by spraying micrometer-sized oil droplets into a counter-current aqueous solution by only solution sending. Meanwhile, at the same time, the emulsion produced in the apparatus disappears rapidly and perfectly by drastically changing the cross-section where liquid droplets pass through in its vessel structure. Such a rapid and perfect phase separation can realize a high processing speed with a small-sized apparatus. Compared with conventional industrial apparatuses, an emulsion-flow apparatus successfully combines the lowest cost superior to a spray column and the highest performance (the highest efficiency and the highest processing speed) comparable to a centrifugal extractor. Furthermore, the emulsion-flow method can also be used for collecting particulate components by utilizing their aggregation onto a liquid-liquid interface and for purifying water polluted by oil with its remarkable phase-separating ability. (author)

  10. Thermal stir welding apparatus

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2011-01-01

    A welding method and apparatus are provided for forming a weld joint between first and second elements of a workpiece. The method includes heating the first and second elements to form an interface of material in a plasticized or melted state interface between the elements. The interface material is then allowed to cool to a plasticized state if previously in a melted state. The interface material, while in the plasticized state, is then mixed, for example, using a grinding/extruding process, to remove any dendritic-type weld microstructures introduced into the interface material during the heating process.

  11. Nitrogen fixation apparatus

    Science.gov (United States)

    Chen, Hao-Lin

    1984-01-01

    A method and apparatus for achieving nitrogen fixation includes a volumetric electric discharge chamber. The volumetric discharge chamber provides an even distribution of an electron beam, and enables the chamber to be maintained at a controlled energy to pressure (E/p) ratio. An E/p ratio of from 5 to 15 kV/atm of O.sub.2 /cm promotes the formation of vibrationally excited N.sub.2. Atomic oxygen interacts with vibrationally excited N.sub.2 at a much quicker rate than unexcited N.sub.2, greatly improving the rate at which NO is formed.

  12. Gas cleaning apparatus

    International Nuclear Information System (INIS)

    Wakerley, M.W.; Asquith, R.W.; Kearney, A.S.; Pratt, R.P.

    1982-01-01

    Apparatus for removing radioactive constituents from a gas flow comprises a cartridge containing iodine absorber and movable from the left-hand position into which it is inserted past a door to the right-hand position where a jacking mechanism lifts it into flow communication with gas inlet and outlet ducts. Double lid systems each comprise one lid closing the cartridge port and another closing the corresponding port leading to the duct. The lids are engaged and lifted when the cartridge is in place, to open the flow paths, and subsequently lowered and disengaged when the cartridge is to be replaced. (author)

  13. Compression test apparatus

    Science.gov (United States)

    Shanks, G. C. (Inventor)

    1981-01-01

    An apparatus for compressive testing of a test specimen may comprise vertically spaced upper and lower platen members between which a test specimen may be placed. The platen members are supported by a fixed support assembly. A load indicator is interposed between the upper platen member and the support assembly for supporting the total weight of the upper platen member and any additional weight which may be placed on it. Operating means are provided for moving the lower platen member upwardly toward the upper platen member whereby an increasing portion of the total weight is transferred from the load indicator to the test specimen.

  14. DNA Sequencing apparatus

    Science.gov (United States)

    Tabor, Stanley; Richardson, Charles C.

    1992-01-01

    An automated DNA sequencing apparatus having a reactor for providing at least two series of DNA products formed from a single primer and a DNA strand, each DNA product of a series differing in molecular weight and having a chain terminating agent at one end; separating means for separating the DNA products to form a series bands, the intensity of substantially all nearby bands in a different series being different, band reading means for determining the position an This invention was made with government support including a grant from the U.S. Public Health Service, contract number AI-06045. The U.S. government has certain rights in the invention.

  15. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  16. Isotope diagnostics apparatus

    International Nuclear Information System (INIS)

    Herrschaft, H.

    1976-01-01

    The invention relates to a measuring probe for an isotope diagnostics apparatus to determine the distribution of radioactive substances in a body by measuring the radiation emanating from this body by means of a multiplicity of measuring probes directed simultaneously towards areas of measuring surfae and carried in guidances of a holding block. The measuring results of the individual probes are recorded separately, thus allowing the possibility of being evaluated separately, too. Measuring probes of this kind are used in multi-channel measuring objects and are useful particularly for determining the regional cerebral blood flow. (orig./ORU) [de

  17. CRANE POSITIONING APPARATUS

    Science.gov (United States)

    Landsiedel, F.W.; Wolff, H.

    1960-06-28

    An apparatus is described for automatically accomplishing the final accurate horizontal positioning of a crane after the latter has been placed to within 1/8 in. of its selected position. For this purpose there is provided a tiltable member on the crane mast for lowering into contact with a stationary probe. Misalignment of the tiltable member, with respect to the probe as the member is lowered, causes tilting of the latter to actuate appropriate switches that energize motors for bringing the mast into proper position. When properly aligned the member is not tilted and a central switch is actuated to indicate the final alignment of the crane.

  18. Control rod testing apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.R.; Ashman, C.M.

    1987-06-02

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means.

  19. Apparatus for chemical synthesis

    Science.gov (United States)

    Kong, Peter C [Idaho Falls, ID; Herring, J Stephen [Idaho Falls, ID; Grandy, Jon D [Idaho Falls, ID

    2011-05-10

    A method and apparatus for forming a chemical hydride is described and which includes a pseudo-plasma-electrolysis reactor which is operable to receive a solution capable of forming a chemical hydride and which further includes a cathode and a movable anode, and wherein the anode is moved into and out of fluidic, ohmic electrical contact with the solution capable of forming a chemical hydride and which further, when energized produces an oxygen plasma which facilitates the formation of a chemical hydride in the solution.

  20. APPARATUS FOR ARC WELDING

    Science.gov (United States)

    Lingafelter, J.W.

    1960-04-01

    An apparatus is described in which a welding arc created between an annular electrode and a workpiece moves under the influence of an electromagnetic field about the electrode in a closed or annular path. This mode of welding is specially suited to the enclosing of nuclear-fuel slugs in a protective casing. For example, a uranium slug is placed in an aluminum can, and an aluminum closure is welded to the open end of the can along a closed or annular path conforming to the periphery of the end closure.

  1. Control rod testing apparatus

    International Nuclear Information System (INIS)

    Gaunt, R.R.; Ashman, C.M.

    1987-01-01

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means

  2. Remote docking apparatus

    International Nuclear Information System (INIS)

    Dent, T.H.; Sumpman, W.C.; Wilhelm, J.J.

    1981-01-01

    The remote docking apparatus comprises a support plate with locking devices mounted thereon. The locking devices are capable of being inserted into tubular members for suspending the support plate therefrom. A vertical member is attached to the support plate with an attachment mechanism attached to the vertical member. A remote access manipulator is capable of being attached to the attachment mechanism so that the vertical member can position the remote access manipulator so that the remote access manipulator can be initially attached to the tubular members in a well defined manner

  3. A novel vision-based PET bottle recycling facility

    International Nuclear Information System (INIS)

    He, Xiangyu; He, Zaixing; Zhang, Shuyou; Zhao, Xinyue

    2017-01-01

    Post-consumer PET bottle recycling is attracting increasing attention due to its value as an energy conservation and environmental protection measure. Sorting by color is a common method in bottle recycling; however, manual operations are unstable and time consuming. In this paper, we design a vision-based facility to perform high-speed bottle sorting. The proposed facility consists mainly of electric and mechanical hardware and image processing software. To solve the recognition problem of isolated and overlapped bottles, we propose a new shape descriptor and utilize the support vector data description classifier. We use color names to represent the colors in the real world in order to avoid problems introduced by colors that are similar. The facility is evaluated by the target error, outlier error and total error. The experimental results demonstrate that the facility we developed is capable of recycling various PET bottles. (paper)

  4. Isotope separation apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.I.

    1983-01-01

    This application discloses a method for and an apparatus in which isotopes of an element in a compared are separated from each other while that compound, i.e., including a mixture of such isotopes, flows along a predetermined path. The apparatus includes a flow tube having a beginning and an end. The mixture of isotopes is introduced into the flow tube at a first introduction point between the beginning and the end thereof to flow the mixture toward the end thereof. A laser irradiates the flow tube dissociating compounds of a preselected one of said isotopes thereby converting the mixture in an isotopically selective manner. The dissociation products are removed from the tube at a first removal point between the first introduction point and the end. The dissociation product removed at the the first removal point are reconverted back into the comound thereby providing a first stage enriched compound. This first stage enriched compound is reintroduced into the flow tube at a second introduction point between the beginning thereof and the first introduction point. Further product is removed from the flow tube at a second removal point between the second introduction point and the first introduction point. The second introduction point is chosen so that the isotope composition of the first stage enriched compound is approximately the same as that of the compound in the flow tube

  5. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  6. Percussive arc welding apparatus

    Science.gov (United States)

    Hollar, Jr., Donald L.

    2002-01-01

    A percussive arc welding apparatus includes a generally cylindrical actuator body having front and rear end portions and defining an internal recess. The front end of the body includes an opening. A solenoid assembly is provided in the rear end portion in the internal recess of the body, and an actuator shaft assembly is provided in the front end portion in the internal recess of the actuator body. The actuator shaft assembly includes a generally cylindrical actuator block having first and second end portions, and an actuator shaft having a front end extending through the opening in the actuator body, and the rear end connected to the first end portion of the actuator block. The second end portion of the actuator block is in operational engagement with the solenoid shaft by a non-rigid connection to reduce the adverse rebound effects of the actuator shaft. A generally transversely extending pin is rigidly secured to the rear end of the shaft. One end of the pin is received in a slot in the nose housing sleeve to prevent rotation of the actuator shaft during operation of the apparatus.

  7. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  8. The Effects of Fuel and Cylinder Gas Densities on the Characteristics of Fuel Sprays for Oil Engines

    Science.gov (United States)

    Joachim, W F; Beardsley, Edward G

    1928-01-01

    This investigation was conducted as a part of a general research on fuel-injection engines for aircraft. The purpose of the investigation was to determine the effects of fuel and cylinder gas densities with several characteristics of fuel sprays for oil engines. The start, growth, and cut-off of single fuel sprays produced by automatic injection valves were recorded on photographic film by means of special high-speed motion-picture apparatus. This equipment, which has been described in previous reports, is capable of taking twenty-five consecutive pictures of the moving spray at the rate of 4,000 per second. The penetrations of the fuel sprays increased and the cone angles and relative distributions decreased with increase in the specific gravity of the fuel. The density of the gas into which the fuel sprays were injected controlled their penetration. This was the only characteristic of the chamber gas that had a measurable effect upon the fuel sprays. Application of fuel-spray penetration data to the case of an engine, in which the pressure is rising during injection, indicated that fuel sprays may penetrate considerably farther than when injected into a gas at a density equal to that of the gas in an engine cylinder at top center.

  9. Towards a sensory congruent beer bottle: Consumer associations between beer brands, flavours, and bottle designs

    OpenAIRE

    Fenko, Anna; Heiltjes, Sanne; van den Berg-Weitzel, Lianne; Lloyd, Peter; Bohemia, Erik

    2016-01-01

    Sensory packaging design congruent with product and brand characteristics may be used as an innovative tool to communicate product and brand values to consumers and to enhance taste experience. This study investigated whether consumers associate sensory properties of beer bottles with certain brand values and beer flavours. Participants evaluated five beer products on a list of brand values, flavour characteristics and package characteristics. The results demonstrated that consumers systemati...

  10. Developing a dispersant spraying capability

    Energy Technology Data Exchange (ETDEWEB)

    Gill, S.D.

    1979-01-01

    In developing a national dispersant spraying capability, the Canadian Coast Guard (CCG) has undertaken a modification program to enable the conventional offshore spraying gear to be mounted on almost any vessel of convenience. Smaller, more versatile inshore spraying vessels and pumps have been designed and built. With the popularization of concentrated dispersants, the inshore pumping equipment can be used aboard hovercraft for special application situations. A program of acquiring mobile dispersant storage tanks has been undertaken with auxiliary equipment that will facilitate the shipment of dispersants in bulk by air freight. Work also has commenced on extending the dispersant application program to include the CCG fleet of helicopters.

  11. Preferred states of the apparatus

    Indian Academy of Sciences (India)

    Abstract. A simple one-dimensional model for the system–apparatus interaction is analysed. The system is a spin-1/2 particle, and its position and momentum degrees constitute the apparatus. An analysis involving only unitary Schrödinger dynamics illustrates the nature of the correlations established in the ...

  12. Endocrine disruptors in bottled mineral water: total estrogenic burden and migration from plastic bottles.

    Science.gov (United States)

    Wagner, Martin; Oehlmann, Jörg

    2009-05-01

    Food consumption is an important route of human exposure to endocrine-disrupting chemicals. So far, this has been demonstrated by exposure modeling or analytical identification of single substances in foodstuff (e.g., phthalates) and human body fluids (e.g., urine and blood). Since the research in this field is focused on few chemicals (and thus missing mixture effects), the overall contamination of edibles with xenohormones is largely unknown. The aim of this study was to assess the integrated estrogenic burden of bottled mineral water as model foodstuff and to characterize the potential sources of the estrogenic contamination. In the present study, we analyzed commercially available mineral water in an in vitro system with the human estrogen receptor alpha and detected estrogenic contamination in 60% of all samples with a maximum activity equivalent to 75.2 ng/l of the natural sex hormone 17beta-estradiol. Furthermore, breeding of the molluskan model Potamopyrgus antipodarum in water bottles made of glass and plastic [polyethylene terephthalate (PET)] resulted in an increased reproductive output of snails cultured in PET bottles. This provides first evidence that substances leaching from plastic food packaging materials act as functional estrogens in vivo. Our results demonstrate a widespread contamination of mineral water with xenoestrogens that partly originates from compounds leaching from the plastic packaging material. These substances possess potent estrogenic activity in vivo in a molluskan sentinel. Overall, the results indicate that a broader range of foodstuff may be contaminated with endocrine disruptors when packed in plastics.

  13. Ampoule Bottle Detection Equipment Research and Development

    Directory of Open Access Journals (Sweden)

    Liu Xinyu

    2015-01-01

    Full Text Available With the continuous development of computer vision technology, its application is more and more extensive. In recent years, the application of computer vision technology in the area of medical packing detection also made great achievements. This paper detailed a scientific and reasonable scheme of an ampoule bottle automatic detection equipment. In this scheme we use the computer vision technology and CNC technology, and select the appropriate transport mechanism and cameras to get images of ampoules. After getting the images, we use a software named MATLAB, which can deal with the images, to obtain some useful information about the ampoules. Then we can evaluate the quality of the ampoule according to these information.

  14. Archimedes force on Casimir apparatus

    Directory of Open Access Journals (Sweden)

    Shevchenko V.

    2016-01-01

    Full Text Available The talk addresses a problem of Casimir apparatus in weak gravitational field, surrounded by a dense medium. The falling of the apparatus has to be governed by the equivalence principle, taking into account proper contributions to the weight of the apparatus from its material part and from distorted quantum fields. We discuss general ex pression for the corresponding force in terms of the effective action. By way of example we compute explicit expression for Archimedes force, acting on the Casimir apparatus of finite size, immersed into thermal bath of free scalar field. It is shown that besides universal term, proportional to the volume of the apparatus, there are non-universal quantum corrections, depending on the boundary conditions.

  15. Flexible ultrasonic pipe inspection apparatus

    Science.gov (United States)

    Jenkins, Charles F.; Howard, Boyd D.

    1998-01-01

    A flexible, modular ultrasonic pipe inspection apparatus, comprising a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present.

  16. Radioactive waste treatment apparatus

    International Nuclear Information System (INIS)

    Abrams, R.F.; Chellis, J.G.

    1983-01-01

    Radioactive waste treatment apparatus is disclosed in which the waste is burned in a controlled combustion process, the ash residue from the combustion process is removed and buried, the gaseous effluent is treated in a scrubbing solution the pH of which is maintained constant by adding an alkaline compound to the solution while concurrently extracting a portion of the scrubbing solution, called the blowdown stream. The blowdown stream is fed to the incinerator where it is evaporated and the combustibles in the blowdown stream burned and the gaseous residue sent to the scrubbing solution. Gases left after the scrubbing process are treated to remove iodides and are filtered and passed into the atmosphere

  17. Radioactive aerosol inhalation apparatus

    International Nuclear Information System (INIS)

    Bordoni, M.E.; Lieberman, E.

    1987-01-01

    An aerosol inhalation apparatus for supplying an aerosol mist containing radioactive tagged particles to a subject is described comprising a reusable radiation-shielding container having lid means. The contents of the container are readily accessible. A radioactive aerosol inhalation device includes first and second conduit means in the container and passing therethrough, means for communicating with an air passageway of a subject connected to the first and second conduit means externally of the container. Valve means control exhalation from the second conduit means. A nebulizer is within the container connected to the first conduit means. Means are positioned at least in part within the container and in fluid communication with the nebulizer for allowing introduction of radioactive solution from outside the container into the nebulizer

  18. Spine immobilization apparatus

    Science.gov (United States)

    Lambson, K. H.; Vykukal, H. C. (Inventor)

    1981-01-01

    The apparatus makes use of a normally flat, flexible bladder filled with beads or micro-balloons that form a rigid mass when the pressure within the bladder is decreased below ambient through the use of a suction pump so that the bladder can be conformed to the torso of the victim and provide the desired restraint. The bladder is strapped to the victim prior to being rigidified by an arrangement of straps which avoid the stomach area. The bladder is adapted to be secured to a rigid support, i.e., a rescue chair, so as to enable removal of a victim after the bladder has been made rigid. A double sealing connector is used to connect the bladder to the suction pump and a control valve is employed to vary the pressure within the bladder so as to soften and harden the bladder as desired.

  19. Multichannel Thomson scattering apparatus

    International Nuclear Information System (INIS)

    Bretz, N.; Dimock, D.; Foote, V.; Johnson, D.; Long, D.; Tolnas, E.

    1977-07-01

    A Thomson scattering apparatus for measuring the electron temperature and density along a 90 cm diameter of the PLT plasma has been built. A wide angle objective images the 3 mm x 900 mm ruby laser beam onto an image dissector which rearranges the 300 : 1 image to 20 : 1 forming the input slit of a spectrometer. The stigmatic spectrometer provides 20 wavelength elements of approximately 70 A each. A micro-channel-plate image intensifier optically coupled to a cooled SIT tube provides detection with single frame linearity and 1000 : 1 dynamic range. Spatial profiles of N/sub e/ and T/sub e/ in the range 10 13 - 10 14 cm -3 and 0.05 - 3 keV have an accuracy of 30 √10 13 /N/sub e/ (cm -3 ) percent per 1.2 cm element

  20. Exhaust gas circulation apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Shibano, K.

    1975-01-10

    An exhaust gas recirculation apparatus is described. An exhaust gas recirculation tube is connected between the exhaust pipe and the intake tube and the opening of the tube; the amount of recirculated gas is regulated by a piston-type cycle control valve which is connected to the throttle valve of the carburetor through an arm. The arm is designed in a two-step linkage so that the cycle valve closes the recirculation tube when the throttle valve is at a fully opened angle and a small angle. Therefore, no exhaust gas recirculation occurs when the automobile is in full power, idling, or low running conditions. This prevents lowered engine power at these conditions.

  1. Apparatus for stereotactic surgery

    International Nuclear Information System (INIS)

    Koslow, M.A.M.

    1982-01-01

    Apparatus for stereotactic surgery consisting of a probe and a computerized tomographic scanning system is described. The scanning system comprises a display and means for reconstructing cross-sectional images on the display using data from partial circumferential scans of source and detectors. It operates on the data with an algorithm that provides the difference between the local values of the linear attenuation coefficient and average of these values within a circle centered at each reconstruction point. The scanning system includes a means of maintaining the frames of reference of the probe and scanning system rigid with respect to one another. The position of the probe, which may be a cryogenic probe, with respect to the actual anatomical structure of the body, particularly a human head, may thus be viewed by the surgeon. (author)

  2. 27 CFR 27.207 - Bottles to be used for display purposes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottles to be used for... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER Requirements for Liquor Bottles § 27.207 Bottles to be used for display purposes. Empty liquor bottles may be...

  3. Innovative Design of Plastic Bottle Recycling Box Based on ARM

    Directory of Open Access Journals (Sweden)

    Yuedong Xiong

    2014-04-01

    Full Text Available Aiming at the problems of on-site plastic bottles recycling and the reuse of waste, the automatic recycling system was developed on the basis of ARM. As the main controller, ARM not only controls the mechanical system of the collector to recover and break plastic bottles, but also communicates with and rewards the user by the automatic reward system through the wireless network. The experimental prototype test results show: post treated fragments of plastic bottles are small, which are convenient to transport and take advantage of; the operation of recovery is easy, and the interface of man-machine interaction is friendly which is easy to expand functions.

  4. Absorption/desorption in sprays

    International Nuclear Information System (INIS)

    Naimpally, A.

    1987-01-01

    This survey paper shall seek to present the present state of knowledge concerning absorption and desorption in spray chambers. The first part of the paper presents the theories and formulas for the atomization and break-up of sprays in nozzles. Formulas for the average (sauter-mean) diameters are then presented. For the case of absorption processes, the formulas for the dimensionless mass transfer coefficients is in drops. The total; mass transfer is the total of the transfer in individual drops. For the case of desorption of sparingly soluble gases from liquids in a spray chamber, the mass transfer occurs in the spray just at the point of break-up of the jet. Formulas for the desorption of gases are presented

  5. The frequency of bottle feeding as the main factor of baby bottle tooth decay syndrome

    Directory of Open Access Journals (Sweden)

    Mochamad Fahlevi Rizal

    2010-03-01

    Full Text Available Background: Dental caries remains as main problem in Indonesia and its prevalence is high (90.05%. However, there is no appropriate data that can be used to analyze dental caries in toddlers, especially baby bottle tooth decay syndrome (BBTD, though the number of BBTD cases is high in some pediatric dental clinics (90% of patients visiting the clinics. Even though some factors have already been considered to be the risk factor of BBTD, the main risk factor of BBTD is still unknown, especially BBTD in Indonesia. Purpose: This research was aimed to obtain data relating with bottle-feeding habit in 3-5 year old children in Indonesia and its caries risk. Method: The study was an observational research conducted with clinical examination through caries status (deft of each child deserved by pediatric dentists and through questionnaire distributed to parents to examine the risk factor of BBTD. Observation was conducted on 62 children in the range of age 3 to 5 years old with bottle-feeding habit. Result: The results revealed that status of caries was various. The data showed that the frequency of bottle feeding more than twice could trigger BBTD 2.27 times higher than other factors such as the use of bottle feeding as a pacifier prior sleeping, the period of bottle-feeding, and the breast-feeding experience. Conclusion: though milk as subtract can possibly become a factor triggering caries, the frequency of bottle-feeding is highly considered as main factor. Since it could modulated the bacterial colonization on dental surface, which affects its virulence.Latar belakang: Karies masih menjadi masalah utama di Indonesia. Dalam praktek sehari-hari prevalensi karies masih sangat tinggi (90.05%. Belum ada data yang memadai dalam penelaahan karies yang spesifik pada anak balita selama ini khususnya kasus sindroma karies botol (SKB sementara itu kasus SKB ditemukan sangat tinggi di beberapa klinik gigi anak (90% dari jumlah pasien yang datang ke klinik

  6. Post-treatment of Plasma-Sprayed Amorphous Ceramic Coatings by Spark Plasma Sintering

    Science.gov (United States)

    Chraska, T.; Pala, Z.; Mušálek, R.; Medřický, J.; Vilémová, M.

    2015-04-01

    Alumina-zirconia ceramic material has been plasma sprayed using a water-stabilized plasma torch to produce free standing coatings. The as-sprayed coatings have very low porosity and are mostly amorphous. The amorphous material crystallizes at temperatures above 900 °C. A spark plasma sintering apparatus has been used to heat the as-sprayed samples to temperatures above 900 °C to induce crystallization, while at the same time, a uniaxial pressure of 80 MPa has been applied to their surface. After such post-treatment, the ceramic samples are crystalline and have very low open porosity. The post-treated material exhibits high hardness and significantly increased flexural strength. The post-treated samples have a microstructure that is best described as nanocomposite with the very small crystallites embedded in an amorphous matrix.

  7. Bottled Water: United States Consumers and Their Perceptions of Water Quality

    OpenAIRE

    Hu, Zhihua; Morton, Lois Wright; Mahler, Robert L.

    2011-01-01

    Consumption of bottled water is increasing worldwide. Prior research shows many consumers believe bottled water is convenient and has better taste than tap water, despite reports of a number of water quality incidents with bottled water. The authors explore the demographic and social factors associated with bottled water users in the U.S. and the relationship between bottled water use and perceptions of the quality of local water supply. They find that U.S. consumers are more likely to report...

  8. Study on the Plastic Bottle Recycling Based on Evolution Tree for Technical System

    OpenAIRE

    Yuedong Xiong; Huadong Huang

    2014-01-01

    Technical system theory of evolution tree was used in the study of the plastic bottle recycling, and established the evolutionary line of plastic bottle recycling on the basis of the analysis of plastic bottle recycling recovery evolution tree, and summed up a new smart plastic bottle recycling program. The new recovery recovers and smashes the plastic bottles through technical system, and communicates with users through automatically reward system and rewards the latter. The experimental pro...

  9. Apparatus for localizing disturbances in pressurized water reactors (PWR)

    International Nuclear Information System (INIS)

    Sykora, D.

    1989-01-01

    The invention according to CS-PS 177386, entitled ''Apparatus for increasing the efficiency and passivity of the functioning of a bubbling-vacuum system for localizing disturbances in nuclear power plants with a pressurized water reactor'', concerns an important area of nuclear power engineering that is being developed in the RGW member countries. The invention solves the problems of increasing the reliability and intensification during the operation of the above very important system for guaranteeing the safety of the standard nuclear power plants of Soviet design. The essence of the invention consists in the installation of a simple passively operating supplementary apparatus. Consequently, the following can be observed in the system: first an improvement and simultaneous increase in the reliability of its function during the critical transition period, which follows the filling of the second space with air from the first space; secondly, elimination of the hitherto unavoidable initiating role of the active sprinkler-condensation device present; thirdly, a more effective performance and subjection of the elements to disintegration of the water flowing from the bubbling condenser into the first space; and fourthly, an enhanced utilization of the heat-conducting ability of the water reservoir of the bubbling condenser. Representatives of the supplementary apparatus are autonomous and local secondary systems of the sprinkler-sprayer without an insert, which spray the water under the effect of gravity. 1 fig

  10. Migration of 2-butoxyethyl acetate from polycarbonate infant feeding bottles

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Lund, K.H.

    2003-01-01

    An enforcement campaign was carried out to assess the migration of 2-butoxyethyl acetate (2-BEA) from polycarbonate infant feeding bottles intended for repeated use. Migration was measured by three successive migration tests into two of the European Union official food simulants: distilled water...... and 3% acetic acid testing at 40degrees C for 10 days. The Danish Veterinary and Food Administration (DVFA) has assessed that a migration above 0.33 mg for 2-BEA and a group of eight related substances kg(-1) foodstuff from plastics articles used exclusively for infants is unacceptable. Migration of 2......-BEA was found from eight of 12 bottles. However, migration above the target value of 0.33 mg kg(-1) was not observed in the third decisive test from any of the 12 different brands of polycarbonate feeding bottles. A migration of between 0.05 and 0.26 mg kg(-1) from seven of 12 bottles was measured...

  11. Ascospore release from bottle-shaped asci in Dipodascus albidus.

    Science.gov (United States)

    van Heerden, Ané; Kock, Johan L F; Botes, Piet J; Pohl, Carolina H; Strauss, Catharina J; van Wyk, Pieter W J; Nigam, Santosh

    2005-12-01

    Yeasts utilize different mechanisms to release ascospores of different lengths from bottle-shaped asci. Using electron microscopy, confocal laser scanning microscopy, gas chromatography-mass spectrometry and digital live imaging, the individual release of oval ascospores from tight-fitting narrow bottle-necks, is reported in the yeast Dipodascus albidus. These ascospores are surrounded by compressible, oxylipin-coated sheaths enabling ascospores to slide past each other when forced by turgor pressure and by possible sheath contractions towards the narrowing ascus-neck. In this paper, the release mechanisms of ascospores of various lengths from bottle-shaped asci and produced by different yeasts are compared. We suggest that different release mechanisms, utilizing compressible sheaths or geared-alignment, have possibly evolved to compensate for variation in ascospore length. Alternatively, sheaths and ridges might be two evolutionary solutions to the same biomechanical problem, i.e. to release ascospores irrespective of length from bottle-shaped asci.

  12. Physical, chemical and microbial analysis of bottled drinking water.

    Science.gov (United States)

    Sasikaran, S; Sritharan, K; Balakumar, S; Arasaratnam, V

    2012-09-01

    People rely on the quality of the bottled drinking water, expecting it to be free of microbial contamination and health hazards. To evaluate the quality of bottled drinking water sold in Jaffna peninsula by analysing the physical, chemical and microbial contents and comparing with the recommended Sri Lankan Standard (SLS) values. All bottled water samples sold in Jaffna peninsula were collected. Electrical conductivity, total dissolved solid, pH, calcium, nitrate, total aerobic and anaerobic count, coliform bacterial count and faecal contamination were checked. These are 22 brands of bottled drinking water sold in Jaffna peninsula. The sample had very low electrical conductivity when compared with SLS (750 μS/ cm) and varied from 19 to 253 μS/cm with the mean of 80.53 (±60.92) μS/cm. The pH values of the bottled drinking water brands varied from 4.11 to 7.58 with a mean of 6.2 (±0.75). The total dissolved solid content of the bottled drinking water brands varied from 9 to 123.67 mg/l with a mean of 39.5 (±30.23) mg/l. The calcium content of the bottled drinking water brands varied from 6.48 to 83.77 mg/l with a mean of 49.9 (±25.09) mg/l. The nitrate content of the bottled drinking water brands varied from 0.21 to 4.19 mg/l with the mean of 1.26 (±1.08) mg/l. Aerobic bacterial count varied from 0 to 800 colony forming unit per ml (cfu/ml) with a mean of 262.6 (±327.50) cfu/ml. Among the 22 drinking bottled water brands 14 and 9% of bottled drinking water brands showed fungal and coliform bacterial contaminants respectively. The water brands which contained faecal contamination had either Escherichia coli or Klebsiella spp. The bottled drinking water available for sale do not meet the standards stipulated by SLS.

  13. Computed Tomography characterization of the Green Fiber Bottle

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    process. The Green Fiber Bottle (GFB) is a freeform geometry consisting of cellulose fibers. Accurate dimensional measurements such as wall thickness of the GFB is not possible using Coordinate Measuring Machines (CMMs). XCT on one hand provides an effective means of measuring wall thickness...... and on the other hand it also helps in identifying voids in the order of 110 µm at any location in the bottle geometry....

  14. Rare earth elements in some bottled waters of Serbia

    Directory of Open Access Journals (Sweden)

    Todorović Maja

    2013-01-01

    Full Text Available Twenty-one bottled mineral and spring waters from Serbia were analyzed for 16 inorganic chemical parameters, including lanthanides and yttrium which belong to the group of so-called rare earth elements (REE. REE concentrations in the bottled water samples varied over a broad range, from 5.39 to 1585.82 ng/L. Total concentrations in the bottled water samples were calculated taking into account the classification of lanthanides into heavy (HREE and light (LREE, with yttrium added to the HREE group. The LREE concentrations ranged from 3.62 to 1449.63 ng/L, while those of the HREE were from 0 to 136.19 ng/L. Distinct REE signatures were observed in waters that drained specific rocks. The REE patterns in groundwater from granitic and related rocks showed LREE and HREE enrichment, while groundwater with mafic rock influence exhibited slightly LREE enrichment. Several bottled water samples featured naturally-occurring carbon dioxide, whose solutional capacity contributed to the highest REE concentrations in the analyzed samples. High REE concentrations are also a result of sudden changes in oxidation-reduction conditions, which particularly affect La, Ce and Eu. Aquifers developed in granitic and related rocks (methamorphic and sedimentary rocks constitute favorable environments for HREE in groundwater, corroborated by the occurrence of HREE in bottled water samples. The bottled water samples largely exhibited a negative cerium anomaly and nearly all the samples showed a positive europium anomaly.

  15. Radiation measuring apparatus

    International Nuclear Information System (INIS)

    DiIanni, E.J.; Cooley, H.J.; Fujita, M.; Noback, C.V.

    1986-01-01

    This patent describes an apparatus for measuring radiation field strength comprising in combination, (a) biased potential radiation detector having an output circuit, the detector being of the type that is effective when biased to respond to impingement of radiation by generating an output pulse at its output circuit, and when not biased being ineffective to generate an output pulse when impinged by radiation, (b) biasing means operatively coupled to the radiation detector for selectively biasing the radiation detector to generate an output pulse in response to impingement by radiation, (c) time counting means including timing control means operable to start and terminate time counting, the radiation detector output circuit being operatively coupled to the time counting means and being effective upon generation of an output pulse to cause the time counting means to terminate time counting, (d) master control means operatively coupled to (1) the biasing means to selectively cause the biasing means to bias the radiation detector to respond to impingement by radiation, (2) the time counting means and effective to cause the time counting means to start time counting simultaneously with the operative biasing of the radiation detector, the master control means receiving a signal when the radiation detector generates an output pulse

  16. Nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Nagata, Daizaburo; Yamada, Masao.

    1974-01-01

    Object: To provide a nuclear fusion apparatus in which a magnetic limiter is disposed within a vacuum vessel, said magnetic limiter being supported in such a manner so as to not to exert mechanical action upon said vacuum vessel, thereby minimizing a force applied to the vacuum vessel to easily manufacture the vacuum vessel. Structure: The magnetic limiter disposed within the vacuum vessel is connected to one end of a supporting post which extends through the wall of the vacuum vessel through a seal portion, the other end of the supporting post being secured to a structure such as a house outside the vacuum vessel. The seal portion comprises a bellows of high spring elasticity mounted on the vacuum vessel and a seal element comprised of an electric insulator such as ceramic for connecting the bellows to the supporting post, the supporting post extending through the wall of the vacuum vessel in vacuum-tight fashion, the force applied to the magnetic limiter exerting no influence upon the vacuum vessel. (Kamimura, M.)

  17. Apparatus for internal irradiation

    International Nuclear Information System (INIS)

    Hooft, E.V.

    1980-01-01

    Apparatus for internal irradiation wherein the radioactive material is applied in the shape of a ball row consisting of contiguous radioactive and neutral balls. This ball row is prepared beforehand and is pneumatically transferred to an applicator tube adapted to be introduced into a body cavity. In order that the balls may stay exactly in the right places during the irradiation, the applicator tube is provided with an internal channel having a narrow end portion, passing through a shoulder into the remaining wider portion, and a final ball is added to each ball row, this final ball having a larger diameter than the other balls, so that it is not admitted in the narrow end portion of the internal channel in the applicator tube. Thus, upon introduction of a ball row, the final ball is arrested by the shoulder and keeps the other balls in place. A plurality of applicator tubes may be applied, each of which is associated with an intermediate container in which the ball row is composed. After the irradiation, the ball row is returned through the intermediate container to a sorting device directing the balls to appropriate storage containers. However, the final ball is retained in the intermediate container, so that it may be added to the next ball row to be composed

  18. Apparatus for diffusion separation

    International Nuclear Information System (INIS)

    Nierenberg, W.A.

    1976-01-01

    A diffuser separator apparatus is described which comprises a plurality of flow channels in a single stage. Each of said channels has an inlet port and an outlet port and a constant cross sectional area between said ports. At least a portion of the defining surface of each of said channels is a diffusion separation membrane, and each of said channels is a different cross sectional area. Means are provided for connecting said channels in series so that each successive channel of said series has a smaller cross sectional area than the previous channel of said series. Also provided are a source of gaseous mixture, individual means for flowing said gaseous mixture to the inlet port of each of said channels, gas receiving and analyzing means, individual means for flowing gas passing from each of said outlet ports and means for flowing gas passing through said membranes to said receiving and analyzing means, and individual means for connecting the outlet port of each channel with the inlet port of the channel having the next smaller cross sectional area

  19. Controlled nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Bussard, R.W.; Coppi, B.

    1982-01-01

    A fusion power generating device is disclosed having a relatively small and inexpensive core region which may be contained within an energy absorbing blanket region. The fusion power core region contains apparatus of the toroidal type for confining a high density plasma. The fusion power core is removable from the blanket region and may be disposed and/or recycled for subsequent use within the same blanket region. Thermonuclear ignition of the plasma is obtained by feeding neutral fusible gas into the plasma in a controlled manner such that charged particle heating produced by the fusion reaction is utilized to bootstrap the device to a region of high temperatures and high densities wherein charged particle heating is sufficient to overcome radiation and thermal conductivity losses. The high density plasma produces a large radiation and particle flux on the first wall of the plasma core region thereby necessitating replacement of the core from the blanket region from time to time. A series of potentially disposable and replaceable central core regions are disclosed for a large-scale economical electrical power generating plant

  20. Continuous steel production and apparatus

    Science.gov (United States)

    Peaslee, Kent D [Rolla, MO; Peter, Jorg J [McMinnville, OR; Robertson, David G. C. [Rolla, MO; Thomas, Brian G [Champaign, IL; Zhang, Lifeng [Trondheim, NO

    2009-11-17

    A process for continuous refining of steel via multiple distinct reaction vessels for melting, oxidation, reduction, and refining for delivery of steel continuously to, for example, a tundish of a continuous caster system, and associated apparatus.

  1. Cherry-Slush-Candling Apparatus

    Science.gov (United States)

    Stephens, James B.; Weiss, James R.; Hoover, Gordon

    1996-01-01

    Proposed infrared-scanning apparatus for use in bakeries making cherry pies detect cherry pits remaining in cherry slush after pitting process. Pits detected via their relative opacity to infrared radiation.

  2. INFLATE: INFlate Landing Apparatus Technology

    Science.gov (United States)

    Koryanov, V. V. K.; Da-Poian, V. D. P.

    2018-02-01

    Our project, named INFLATE (INFlatable Landing Apparatus Technology), aims at reducing space landing risks and constraints and so optimizing space missions (reducing cost, mass, and risk and in the same time improving performance).

  3. SPRAY CALCINATION REACTOR

    Science.gov (United States)

    Johnson, B.M.

    1963-08-20

    A spray calcination reactor for calcining reprocessin- g waste solutions is described. Coaxial within the outer shell of the reactor is a shorter inner shell having heated walls and with open regions above and below. When the solution is sprayed into the irner shell droplets are entrained by a current of gas that moves downwardly within the inner shell and upwardly between it and the outer shell, and while thus being circulated the droplets are calcined to solids, whlch drop to the bottom without being deposited on the walls. (AEC) H03 H0233412 The average molecular weights of four diallyl phthalate polymer samples extruded from the experimental rheometer were redetermined using the vapor phase osmometer. An amine curing agent is required for obtaining suitable silver- filled epoxy-bonded conductive adhesives. When the curing agent was modified with a 47% polyurethane resin, its effectiveness was hampered. Neither silver nor nickel filler impart a high electrical conductivity to Adiprenebased adhesives. Silver filler was found to perform well in Dow-Corning A-4000 adhesive. Two cascaded hot-wire columns are being used to remove heavy gaseous impurities from methane. This purified gas is being enriched in the concentric tube unit to approximately 20% carbon-13. Studies to count low-level krypton-85 in xenon are continuing. The parameters of the counting technique are being determined. The bismuth isotopes produced in bismuth irradiated for polonium production are being determined. Preliminary data indicate the presence of bismuth207 and bismuth-210m. The light bismuth isotopes are probably produced by (n,xn) reactions bismuth-209. The separation of uranium-234 from plutonium-238 solutions was demonstrated. The bulk of the plutonium is removed by anion exchange, and the remainder is extracted from the uranium by solvent extraction techniques. About 99% of the plutonium can be removed in each thenoyltrifluoroacetone extraction. The viscosity, liquid density, and

  4. Miniature paint-spray gun for recessed areas

    Science.gov (United States)

    Vanasse, M. A.

    1968-01-01

    Miniature spray gun regulates paints and other liquids to spray at close range, facilitating spraying of remote or recessed areas. Individual valves for regulating air pressure and paint maximizes atomization for low pressure spraying.

  5. Mechanics of sucking: comparison between bottle feeding and breastfeeding

    Directory of Open Access Journals (Sweden)

    Ustrell Josep M

    2010-02-01

    Full Text Available Abstract Background There is very little evidence of the similarity of the mechanics of maternal and bottle feeding. We assessed the mechanics of sucking in exclusive breastfeeding, exclusive bottle feeding, and mixed feeding. The hypothesis established was that physiological pattern for suckling movements differ depending on the type of feeding. According to this hypothesis, babies with breastfeeding have suckling movements at the breast that are different from the movements of suckling a teat of babies fed with bottle. Children with mixed feeding mix both types of suckling movements. Methods Cross-sectional study of infants aged 21-28 days with only maternal feeding or bottle feeding (234 mother-infant pairs, and a randomized open cross-over field trial in newborns aged 21-28 days and babies aged 3-5 months with mixed feeding (125 mother-infant pairs. Primary outcome measures were sucks and pauses. Results Infants aged 21-28 days exclusively bottle-fed showed fewer sucks and the same number of pauses but of longer duration compared to breastfeeding. In mixed feeding, bottle feeding compared to breastfeeding showed the same number of sucks but fewer and shorter pauses, both at 21-28 days and at 3-5 months. The mean number of breastfeedings in a day (in the mixed feed group was 5.83 ± 1.93 at 21-28 days and 4.42 ± 1.67 at 3-5 months. In the equivalence analysis of the mixed feed group, the 95% confidence interval for bottle feeding/breastfeeding ratio laid outside the range of equivalence, indicating 5.9-8.7% fewer suction movements, and fewer pauses, and shorter duration of them in bottle feeding compared with breastfeeding. Conclusions The mechanics of sucking in mixed feeding lay outside the range of equivalence comparing bottle feeding with breastfeeding, although differences were small. Children with mixed feeding would mix both types of sucking movements (breastfeeding and bottle feeding during the learning stage and adopt their own

  6. Apparatus Development In Maros

    Directory of Open Access Journals (Sweden)

    H. Aras Solong

    2015-03-01

    Full Text Available ABSTRACT This study aims to identify and describe 1 Development of Administrative through education and training training promotion transfer and rotation and the application of demotion system non-title under Law No. 43 of 1999 on the development of career civil servants based merit system and work performance and Government Regulation No. 101 of 2000 on Education and Training Training for Civil Servants. 2 Revealing differences in work motivation based on the intensity of the education or training training using Herzbergs Two Factor Theory of extrinsic factors hygiene and intrinsic factors motivator that influence employees motivation Maros regency government in carrying out its duties and functions as members civil in public service. This study uses a quantitative approach to date collection techniques through a questionnaire Questionnaire. Informant are civil servants who occupied echelon II III. And IV while the analysis of the date used quantitative analysis to uncover the implementation of personnel development and employees motivation difference Maros region based on the intensity of the education or training training to get job satisfaction in the public service. The results of this study will reveal that 1 Development of Apparatus for improving the knowledge ability professionalism competence skills can work as a reformer change attitude eager to work motivated to do the work get satisfaction in work and getting justice in employment. 2 The difference in work motivation Maros local government employees affected by extrinsic factors hygiene and intrinsic factor motivator is the variable gain high salary H occupies the first ranking while serving the community satisfaction variables M occupy the last ranking. That is that the satisfaction of serving the people affected by the high salaries earned by the employees to do the job.

  7. Pet Bottle Design, Correlation Analysis Of Pet Bottle Characteristics Subjective Judgment

    Directory of Open Access Journals (Sweden)

    Darko Avramović

    2012-06-01

    Full Text Available Ability to predict consumer’s reaction to particular design solution of the product is very important. Gathering andanalysis of subjective judgments of particular characteristics, based on which the aesthetic of the product is judged,is one of predicting the consumer’s reaction in the future. Knowledge gathered this manner can serve as a referencefor further studies of determining factors for aesthetic results and design quality. There are two opposed opinionsregarding prediction of aesthetic impression. One opinion is that taste of individual cannot be discussed because itis extremely variable and the possibility of meaningful analysis of aesthetic impression is rejected. Other opinionstates that there is a consistent preference of certain aesthetic characteristics despite individual and group differences.Main goal of this paper is to examine the correlation between subjective judgments of certain PET bottlecharacteristics. Analysis showed meaningful correlation between some of the PET bottle characteristics while othercharacteristics showed less correlation. It can be concluded that not all of the characteristics have the same influenceon the aesthetics and design quality of the PET bottle form. Emphasizing the characteristics relative to aesthetics ofthe product can produce better market results, taking in to account that consumer’s buy the product they consider tobe more attractive if other parameters of the product are similar.

  8. Spray coated nanosilver functional layers

    Science.gov (United States)

    Krzemiński, J.; Szałapak, J.; Dybowska-Sarapuk, L.; Jakubowska, M.

    2016-09-01

    Silver coatings are highly conductive functional layers. There are many different ways to product the silver coating but most of them need vacuum or high temperature. Spray coating is a technique that is free of this disadvantages - it doesn't need a cleanroom or high temperature. What's more the layer thickness is about 10 μm. In this article the spray coating process of silver nanolayer is described. Four different inks were tested and measured. The layer resistance was measured and show as a graph. After the layer resistance was measured the adhesion test was performed. The pull-off test was performed on testing machine with special self made module. To conclude the article include the test and measurements of spray coated nanosilver functional layers. The layers was examined for the current conductivity and adhesion force.

  9. Nasal Sprays: How to Use Them Correctly

    Science.gov (United States)

    ... sprays the correct way can take some practice. Path to improved health Prescription nasal sprays come in ... thumb at the bottom and your index and middle fingers on top. Insert the canister tip in ...

  10. Center for Cold Spray Research and Development

    Data.gov (United States)

    Federal Laboratory Consortium — This is the only DoD facility capable of cold spray research and development, production, and field-repair. It features three stationary cold spray systems used for...

  11. Spray casting project final report

    International Nuclear Information System (INIS)

    Churnetski, S.R.; Thompson, J.E.

    1996-08-01

    Lockheed Martin Energy Systems, Inc. (Energy Systems), along with other participating organizations, has been exploring the feasibility of spray casting depleted uranium (DU) to near-net shape as a waste minimization effort. Although this technology would be useful in a variety of applications where DU was the material of choice, this effort was aimed primarily at gamma-shielding components for use in storage and transportation canisters for high-level radioactive waste, particularly in the Multipurpose Canister (MPC) application. In addition to the waste-minimization benefits, spray casting would simplify the manufacturing process by allowing the shielding components for MPC to be produced as a single component, as opposed to multiple components with many fabrication and assembly steps. In earlier experiments, surrogate materials were used to simulate the properties (specifically reactivity and density) of DU. Based on the positive results from those studies, the project participants decided that further evaluation of the issues and concerns that would accompany spraying DU was warranted. That evaluation occupied substantially all of Fiscal Year 1995, yielding conceptual designs for both an intermediate facility and a production facility and their associated engineering estimates. An intermediate facility was included in this study to allow further technology development in spraying DU. Although spraying DU to near-net shape seems to be feasible, a number of technical, engineering, and safety issues would need to be evaluated before proceeding with a production facility. This report is intended to document the results from the spray-casting project and to provide information needed by anyone interested in proceeding to the next step

  12. Diesel spray characterization; Dieselmoottorin polttoainesuihkujen ominaisuudet

    Energy Technology Data Exchange (ETDEWEB)

    Pitkaenen, J.; Turunen, R.; Paloposki, T.; Rantanen, P.; Virolainen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Internal Combustion Engine Lab.

    1997-10-01

    Fuel injection of diesel engines will be studied using large-scale models of fuel injectors. The advantage of large-scale models is that the measurement of large-scale diesel sprays will be easier than the measurement of actual sprays. The objective is to study the break-up mechanism of diesel sprays and to measure drop size distributions in the inner part of the spray. The results will be used in the development of diesel engines and diesel fuels. (orig.)

  13. "Teaching" an Industrial Robot To Spray

    Science.gov (United States)

    Evans, A. R.; Sweet, G. K.

    1982-01-01

    Teaching device, consisting of spacer rod or tube with three-pointed tip and line level, is used during pattern "teach-in" to make sure that robot manipulator holds spray gun perpendicular to surface to be sprayed and at right distance from it. For slanted surfaces angle adapter is added between spacer rod and line-level indicator. Angle is determined by slope of surface to be sprayed, thus allowing a perpendicular spray pattern against even slanted surfaces.

  14. Radium activity measurements in bottled mineral water

    International Nuclear Information System (INIS)

    Kappke, Jaqueline; Paschuk, Sergei A.; Correa, Janine N.; Denyak, Valeriy; Reque, Marilson; Rocha, Paschuk; Rocha, Zildete; Santos, Talita O.

    2011-01-01

    This work presents the preliminary results of 226 Ra activity measurements of fifteen samples of bottled mineral water acquired at markets of Curitiba-PR, Brazil. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology - Parana (UTFPR) in collaboration with the Center of Nuclear Technology Development of Brazilian Nuclear Energy Committee (CNEN). The experimental setup was based on the electronic radon detector RAD7 (Durridge Company, Inc.). The measurements were carried out with a special kit of accessory vessels (vials) RAD7 H 2 O, which allows one to identify the 222 Rn activity concentration in small water samples of 40 mL and 250 mL in the range going from less than 30 pCi/L to greater than 10 5 pCi/L. During each measurement a vial from RAD H 2 O was poured with a sample of water. The air pump, included in the close loop aeration circuit and connected to the vial and RAD7 detector, operated for five minutes to snatch the sample of air maintained above the level of water sample and transporting it from the vial through the system. Evaluation of the concentration of soluble radium ( 226 Ra) salts in water and their activity was performed after 30 days when 222 Rn in the water samples reached secular equilibrium. The background measurements were performed using the samples of the distilled water. Considering the importance of background measurements, it was found that the value suggested by user Manual protocol (RAD7) for the case of low activity radon measurements, has to be slightly modified. (author)

  15. High-Q plasmonic bottle microresonator

    Science.gov (United States)

    Mohd Nasir, M. Narizee; Ding, Ming; Murugan, G. Senthil; Zervas, Michalis N.

    2014-03-01

    In this paper, we demonstrate a hybrid plasmonic bottle microresonator (PBMR) which supports whispering gallery modes (WGMs) along with surface plasmon waves (SPWs) for high performance optical sensor applications. The BMR was fabricated through "soften-and-compress" technique with a thin gold layer deposited on top of the resonator. A polarization-resolved measurement was set-up in order to fully characterize the fabricated PBMR. Initially, the uncoated BMR with waist diameter of 181 μm, stem diameter of 125 μm and length of 400 μm was fabricated and then gold film was deposited on the surface. Due to surface curvature, the gold film covering half of the BMR had a characteristic meniscus shape and maximum thickness of 30 nm. The meniscus provides appropriately tapered edges which facilitate the adiabatic transformation of BMR WGMs to SPWs and vice versa. This results in low transition losses, which combined with partially-metal-coated resonator, can result in high hybrid-PBMR Q's. The transmission spectra of the hybrid PBMR are dramatically different to the original uncoated BMR. Under TE(TM) excitation, the PBMR showed composite resonances with Q of ~2100(850) and almost identical ~ 3 nm FSR. We have accurately fitted the observed transmission resonances with Lorentzian-shaped curves and showed that the TE and TM excitations are actually composite resonances comprise of two and three partially overlapping resonances with Q's in excess of 2900 and 2500, respectively. To the best of our knowledge these are the highest Qs observed in plasmonic microcavities.

  16. Bottled drinking water: Water contamination from bottle materials (glass, hard PET, soft PET), the influence of colour and acidification

    International Nuclear Information System (INIS)

    Reimann, Clemens; Birke, Manfred; Filzmoser, Peter

    2010-01-01

    A test comparing concentrations of 57 chemical elements (Ag, Al, As, B, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Ho, I, K, La, Li, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sm, Sn, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn and Zr) determined by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) in 294 samples of the same bottled water (predominantly mineral water) sold in the European Union in glass and PET bottles demonstrates significant (Wilcoxon rank sum test, α = 0.05) differences in median concentrations for Sb, Ce, Pb, Al, Zr, Ti, Th, La, Pr, Fe, Zn, Nd, Sn, Cr, Tb, Er, Gd, Bi, Sm, Y, Lu, Dy, Yb, Tm, Nb and Cu. Antimony has a 21x higher median value in bottled water when sold in PET bottles (0.33 vs. 0.016 μg/L). Glass contaminates the water with Ce (19x higher than in PET bottles), Pb (14x), Al (7x), Zr (7x), Ti, Th (5x), La (5x), Pr, Fe, Zn, Nd, Sn, Cr, Tb (2x), Er, Gd, Bi, Sm, Y, Lu, Yb, Tm, Nb and Cu (1.4x). Testing an additional 136 bottles of the same water sold in green and clear glass bottles demonstrates an important influence of colour, the water sold in green glass shows significantly higher concentrations in Cr (7.3x, 1.0 vs. 0.14 μg/L), Th (1.9x), La, Zr, Nd, Ce (1.6x), Pr, Nb, Ti, Fe (1.3x), Co (1.3x) and Er (1.1x). One hundred and twenty-six bottles of three different materials (glass, hard PET and soft PET) in 5 principal colours (clear, light and dark green and blue, brown) were subsequently washed and then filled with high purity water (18.2 MΩ cm). A portion of the bottles where left at the original average pH of the water (pH 6.5) while the remaining bottles were acidified to pH 3.5 with HNO 3 . Concentrations of the same 57 elements as above were determined after 1, 2, 3, 4, 5, 15, 30, 56, 80 and 150 days of leaching. Results substantiate the observations from the direct comparison of the same water sold in different bottle types (colour). For most elements leaching is

  17. Influence of the spray velocity on arc-sprayed coating structures

    Science.gov (United States)

    Steffens, H.-D.; Nassenstein, K.

    1999-09-01

    Thermal spray processes such as plasma spraying and HVOF have gained markets due to a steady process of development of materials and equipment. One disadvantage of thermal spray processes is that costs must be competitive compared to techniques such as PTA and electroplating. In order to reduce costs, the more economical spray processes like conventional wire flame spraying, as well as arc spraying, are becoming more popular. There are modern arc spray gun designs on the market that meet the requirements of modern coating properties, for example aviation overhaul applications as well as the processing of cored wires. Nevertheless, the physical basis of arc spraying is well known. The aim of the present investigation is to show how the influence of spray velocity (not particle velocity) affects coating structure with respect to arc spray parameters.

  18. 14 CFR 23.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 23.239 Section 23.239 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Handling Characteristics § 23.239 Spray characteristics. Spray may not dangerously obscure the vision of...

  19. 14 CFR 29.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 29.239 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Flight Ground and Water Handling Characteristics § 29.239 Spray characteristics. If certification for water operation is requested, no spray characteristics...

  20. 14 CFR 27.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 27.239 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Flight Ground and Water Handling Characteristics § 27.239 Spray characteristics. If certification for water operation is requested, no spray characteristics...

  1. Albendazole Microparticles Prepared by Spray Drying Technique ...

    African Journals Online (AJOL)

    Purpose: To enhance the dissolution of albendazole (ABZ) using spray-drying technique. Method: ABZ binary mixtures with Kollicoat IR® (KL) and polyvinyl pyrrolidone (PVP) in various drug to polymer ratios (1: 1, 1: 2 and 1; 4) were prepared by spray-drying. The spray-dried particles were characterized for particle shape, ...

  2. Flexible ultrasonic pipe inspection apparatus

    Science.gov (United States)

    Jenkins, C.F.; Howard, B.D.

    1998-06-23

    A flexible, modular ultrasonic pipe inspection apparatus, comprises a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present. 7 figs.

  3. Natural radioactivity in bottled mineral water available in Australia

    International Nuclear Information System (INIS)

    Cooper, M.B.; Ralph, B.J.; Wilks, M.J.

    1981-08-01

    The levels of naturally-occurring radioactive elements in bottled mineral water, commercially available in Australia, have been assessed. The survey concentrated upon 226 Ra, 228 Ra and 210 Pb, radionuclides which have a high toxicity in drinking water. Detectable levels of 226 Ra were found to range from 0.02Bq/1 to 0.32Bq/1 in locally-bottled water and from 0.02Bq/1 to 0.44Bq/1 in imported brands. 210 Pb levels were found to be generally very low ( 228 Ra content of bottled water will have a similar distribution to that of 226 Ra. Concentrations of 228 Ra in excess of 0.7Bq/1 were measured in a number of samples. The radiological health implications of the consumption of bottled mineral water are discussed with reference to existing drinking water standards and also in terms of radiation exposure and the increased risk to health. It was concluded that, although some brands of water contain radioactivity in excess of the drinking-water limits recommended by Australian and overseas authorities, the annual radiation dose to an individual will be below the dose-equivalent limits recommended by the International Commission on Radiological Protection for life-long exposure. The increased risk of radiation-induced fatal disease due to the consumption of bottled mineral water is estimated to be less than 10 -5 and is therefore negligible

  4. [Safety verification for reuse of PET and glass bottles].

    Science.gov (United States)

    Hayashi, Eiichi; Imai, Toshio; Niimi, Hiroji

    2011-01-01

    In order to verify the safety associated with reusing PET and glass bottles, a challenge test was conducted with five surrogate contaminants: 1,1,1-trichloroethane, chlorobenzene, toluene, benzophenone and phenyl cyclohexane. Bottles were filled with a cocktail solution of these contaminants and stored at 50 °C for 7 days, then washed with water and alkaline solutions. Material and migration tests were conducted at each step. The material test results showed that 430-1,440 µg/g of the contaminants were retained after water washing, and that even after washing with a 3.5% NaOH solution, 225-925 µg/g of the contaminants were retained. The migration tests revealed that 0.095-7.35 µg/mL of the contaminants were eluted. Similar tests were conducted with a soft drink ingredient, limonene. The results revealed that 48 µg/g of limonene was retained even after washing with NaOH solution, and that 0.16 µg/mL of limonene was eluted. Conversely, no contaminants were eluted from glass bottles after washing with the NaOH solution. Thus, from the viewpoint of safety and the preservation of content quality, PET bottles are not considered suitable for reuse when compared with glass bottles.

  5. Fluid dynamics following flow shut-off in bottle filling

    Science.gov (United States)

    Thete, Sumeet; Appathurai, Santosh; Gao, Haijing; Basaran, Osman

    2012-11-01

    Bottle filling is ubiquitous in industry. Examples include filling of bottles with shampoos and cleaners, engine oil and pharmaceuticals. In these examples, fluid flows out of a nozzle to fill bottles in an assembly line. Once the required volume of fluid has flowed out of the nozzle, the flow is shut off. However, an evolving fluid thread or string may remain suspended from the nozzle following flow shut-off and persist. This stringing phenomenon can be detrimental to a bottle filling operation because it can adversely affect line speed and filling accuracy by causing uncertainty in fill volume, product loss and undesirable marring of the bottles' exterior surfaces. The dynamics of stringing are studied numerically primarily by using the 1D, slender-jet approximation of the flow equations. A novel feature entails development and use of a new boundary condition downstream of the nozzle exit to expedite the computations. While the emphasis is on stringing of Newtonian fluids and use of 1D approximations, results will also be presented for situations where (a) the fluids are non-Newtonian and (b) the full set of equations are solved without invoking the 1D approximation. Phase diagrams will be presented that identify conditions for which stringing can be problematic.

  6. Oxymetazoline Metered Dose Spray: Factors Affecting Delivery Volume.

    Science.gov (United States)

    Hakim, Mumin; Walia, Hina; Rafiq, Mahmood; Grannell, Timothy; Cartabuke, Richard S; Tobias, Joseph D

    2016-01-01

    The current study compared the amount of oxymetazoline delivered by various anesthesia providers when holding the bottle in the upright and inverted position. Additionally, the amount delivered from a full bottle and a half-full bottle was also investigated. Using an analytical balance that was calibrated to zero, we evaluated the impact the position of the bottle and the volume of oxymetazoline in the bottle had on the amount being delivered by both anesthesia staff and trainees. When using both filled and half-filled bottles, the amount delivered increased significantly when comparing the upright versus inverted position. With a full bottle, the amount delivered when the bottle was inverted increased almost 10-fold from 62 ± 80 to 606 ± 366 μL (p oxymetazoline delivered for metered dose bottles. Given the potential for severe end-organ effects with excessive dosage, alternative means of delivery are needed for its perioperative use.

  7. Spray solidification of nuclear waste

    International Nuclear Information System (INIS)

    Bonner, W.F.; Blair, H.T.; Romero, L.S.

    1976-08-01

    The spray calciner is a relatively simple machine. Operation is simple and is easily automated. Startup and shutdown can be performed in less than an hour. A wide variety of waste compositions and concentrations can be calcined under easily maintainable conditions. Spray calcination of high-level and mixed high- and intermediate-level liquid wastes has been demonstrated. Waste concentrations of from near infinite dilution to less than 225 liters per tonne of fuel are calcinable. Wastes have been calcined containing over 2M sodium. Feed concentration, composition, and flowrate can vary rapidly by over a factor of two without requiring operator action. Wastes containing mainly sodium cations can be spray calcined by addition of finely divided silica to the feedstock. A remotely replaceable atomizing nozzle has been developed for use in plant-scale equipment. Calciner capacity of over 75 l/h has been demonstrated in pilot-scale equipment. Sintered stainless steel filters are effective in deentraining over 99.9 percent of the solids that result from calcining the feedstock. The volume of recycle required from the effluent treatment system is very small. Vibrator action maintains the calcine holdup in the calciner at less than 1 kg. Successful remote operation and maintenance of a heated-wall spray calciner have been demonstrated while processing high-level waste. Radionuclide volatilization was acceptably low

  8. Transdermal Spray in Hormone Delivery

    African Journals Online (AJOL)

    and adverse effects and maximum efficacy as well as patients' compliance [1]. Transdermal dosage forms are .... learning and memory in healthy postmenopausal women stabilized on estrogen, over 26 weeks. When the ... forearm instead until the areolae were the same color again and then applied 1 spray to each forearm ...

  9. No Heat Spray Drying Technology

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, Charles [ZoomEssence, Inc., Hebron, KY (United States)

    2016-06-15

    No Heat Spray Drying Technology. ZoomEssence has developed our Zooming™ spray drying technology that atomizes liquids to powders at ambient temperature. The process of drying a liquid into a powder form has been traditionally achieved by mixing a heated gas with an atomized (sprayed) fluid within a vessel (drying chamber) causing the solvent to evaporate. The predominant spray drying process in use today employs air heated up to 400° Fahrenheit to dry an atomized liquid into a powder. Exposing sensitive, volatile liquid ingredients to high temperature causes molecular degradation that negatively impacts solubility, stability and profile of the powder. In short, heat is detrimental to many liquid ingredients. The completed award focused on several areas in order to advance the prototype dryer to a commercial scale integrated pilot system. Prior to the award, ZoomEssence had developed a prototype ‘no-heat’ dryer that firmly established the feasibility of the Zooming™ process. The award focused on three primary areas to improve the technology: (1) improved ability to formulate emulsions for specific flavor groups and improved understanding of the relationship of emulsion properties to final dry particle properties, (2) a new production atomizer, and (3) a dryer controls system.

  10. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  11. The Conservation Ideological State Apparatus

    Directory of Open Access Journals (Sweden)

    Jared D Margulies

    2018-01-01

    Full Text Available This article considers Louis Althusser's theory of the ideological state apparatuses (ISAs for advancing political ecology scholarship on the functioning of the state in violent environments. I reflect on a series of events in which a state forest department in South India attempted to recast violent conflicts between themselves and local communities over access to natural resources and a protected area as a debate over human-wildlife conflicts. Through the example of conservation as ideology in Wayanad, Kerala, I show how the ISAs articulate the functioning of ideology within the state apparatuses in order for us to understand the larger mechanics of the state apparatus and the reproduction of the relations of production necessary for the reproduction of capitalism. Revisiting the ISAs as a theoretical framework for studies in political ecology and conservation is timely given the resurgence of militarised conservation tactics, the emancipatory aims of Althusser's theory, and political ecology's turn towards praxis.

  12. Method to Determine the Stress-Strain Response of As-Formed Thin-Walled Tubular Structures Using a Flaring Apparatus

    Science.gov (United States)

    Jurendic, S.; Anderson, D.

    2017-09-01

    Finite element simulations are used extensively to refine the forming steps of draw and wall iron (DWI) aluminum bottles; therefore, accurate material data is required Unfortunately, the material properties of the base sheet cannot presently be used for simulation of the later forming stages due to preceding significant deformation (ironing) and thermal treatments. Measuring the stress-strain response using traditional methods (e.g. tensile test) becomes increasingly difficult at later stages of the bottle forming process due to a significant diameter reduction of the bottle neck from successive die-necking stages. Moreover, failure during forming tends to occur in the final deformation stages when the bottle opening is rolled over, creating a brim roll, at which point brim roll splits may occur. Knowledge of the stress-strain response prior to the roll over may lead to improved product design, reduced waste, and an optimized product. Therefore, this work details a flaring apparatus and data analysis method to determine the stress-strain response in the die-necked region of thin-walled aluminum bottles fabricated from AA3104 sheet metal.

  13. Comparison of nasal sprays and irrigations in the delivery of topical agents to the olfactory mucosa.

    Science.gov (United States)

    Lam, Kent; Tan, Bruce K; Lavin, Jennifer M; Meen, Eric; Conley, David B

    2013-12-01

    Sinonasal diseases are often treated with topical agents administered through various application techniques, but few prior studies have examined their distribution to the olfactory mucosa. The purpose of this study was to compare the distribution of nasal irrigations to sprays within the olfactory cleft. Human cadaveric study. Eight cadaveric heads, providing a total of 15 nasal sides, underwent treatment with methylene blue solution. Application utilized a pressurized spray device followed by an irrigation squeeze bottle, both used according to manufacturer instructions. Videos and images from six standardized anatomical positions were recorded by rigid nasal endoscopy prior to and following each method of agent delivery. Using the acquired images, three reviewers blinded to the means of application scored the approximate surface area stained. An image-analysis program was additionally calibrated and used to measure pixel intensity in order to quantify surface delivery of methylene blue. Based on both blinded reviewer ratings and image pixel intensity measurements, irrigations demonstrated a greater extent and intensity of staining than sprays within the sphenoethmoid recess, superior turbinate, and superior olfactory cleft (all P Sprays and irrigations, however, were comparable in the extent of staining at the nasal vestibule (P > 0.05), inferior turbinate (P = 0.04), and middle turbinate (P > 0.05). Compared to sprays, irrigations provide a more effective method of delivering topical agents to the posterior and superior aspects of the nasal cavity. The thorough distribution of irrigations has important clinical implications for improving the delivery of therapeutic agents to the olfactory mucosa. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Relationship between breastfeeding, bottle-feeding and development of malocclusion.

    Science.gov (United States)

    Narbutytė, Indrė; Narbutytė, Agnė; Linkevičienė, Laura

    2013-01-01

    The importance of breastfeeding to the child's psychological and physical development is evidence-based. However, scientific literature contains controversial opinions on its influence to the development of maxillofacial system. This article aims at reviewing the effects of breastfeeding and bottle-feeding to the development of malocclusion and non-nutritive sucking habits. Thirty-four articles analyzing the above mentioned associations were selected from Pubmed database. Breastfeeding and bottle-feeding may have different impact on the development of maxillofacial system due to unequal functional load of certain facial muscles involved in the feeding processes. Shortage of scientific research prevents from relating bottle-feeding with the development of skeletal malocclusions. Prolonged breastfeeding may have protective effect on developing posterior crossbite and anterior openbite. However, conflicting opinions have been observed. It has been stated that longer duration of breastfeeding diminishes the risk of acquiring non - nutritive sucking habits.

  15. Flexural Toughness of Ring-Shaped Waste Bottle Fiber Concrete

    Directory of Open Access Journals (Sweden)

    Faisal S. K.

    2016-01-01

    Full Text Available Polyethylene terephthalate (PET bottles are plastic containers that are typically discarded, and thus, cause environmental pollution. To solve this problem, PET bottles are recycled incorporating with concrete. A ring-shaped PET (RPET fiber are introduced in this study and designed with a special shape to mobilize fiber yielding rather than fiber pullout. Therefore, aim of this paper is to investigate the influence of RPET bottles fibre in terms of toughness strength. The width of RPET fibers is fixed at 5 and 10 mm and the loads were applied to the third points of the specimen. The experiment indicates that RPET-5 and RPET-10 FC presented an increase in the toughness index of I20 on averages of 23.1% and 39.9% respectively, compared to normal specimens. It can conclude that incorporating RPET fiber in concrete presents significant improved of concrete properties.

  16. One-bottle silane coupling agent containing 4-META.

    Science.gov (United States)

    Kitahara, Nobuya; Itoh, Kazuo; Kusunoki, Mizuho; Oikawa, Misa; Miyazaki, Takashi

    2013-01-01

    The effectiveness of commercial and experimental silane coupling agents was evaluated by measuring their shear bond strengths to a ceramic disk. Experimental one-bottle silane coupling agents were prepared using 3-MPTS, 4-META, and resin monomers. The surfaces of two ceramic disks (IPS e-max, Ivoclar Vivadent AG, Schaan, Lichtenstein) were treated by a silane coupling agent to bond them to each other; this bonding was mediated by a commercial flowable resin composite (Clearfil Majesty LV, Kuraray, Tokyo, Japan). A commercial silane coupling agent (Clearfil Porcelain Bond Activator, Kuraray, Tokyo, Japan) modified by adding 4-META exhibited a significantly higher bond strength than the unmodified commercial one-bottle silane coupling agent. Among the tested materials, two experimental one-bottle silane coupling agents composed of 5% 4-META, 45% 3-MPTS, and 50% resin monomers exhibited statistically highest bond strengths.

  17. Quality status of bottled water brands in Pakistan

    International Nuclear Information System (INIS)

    Kahlown, M. A.; Tahir, M.A.

    2005-01-01

    The (PCRWR) has carried out a study to evaluate the quality of mineral water brands available in the market owing to demand of general public and consumer associations. Twenty one brands of bottled water were collected from Islamabad and Rawalpindi. Each water sample was analyzed for 24 aesthetic, physico-chemical and bacteriological water quality parameters by adopting standard analytical methods. It was observed that only 10 out of 21 brands (47.62%) were fit for drinking purpose. The remaining eleven brands (52.38%), including one imported brand, were found unsafe for human consumption. It was also concluded that present situation of water quality of bottled water is due to lack of legislation for water quality control. Hence there is a dire need for a legal organization to monitor and regulate the quality issues of bottled water industry. (author)

  18. Apparatus for control of mercury

    Science.gov (United States)

    Downs, William; Bailey, Ralph T.

    2001-01-01

    A method and apparatus for reducing mercury in industrial gases such as the flue gas produced by the combustion of fossil fuels such as coal adds hydrogen sulfide to the flue gas in or just before a scrubber of the industrial process which contains the wet scrubber. The method and apparatus of the present invention is applicable to installations employing either wet or dry scrubber flue gas desulfurization systems. The present invention uses kraft green liquor as a source for hydrogen sulfide and/or the injection of mineral acids into the green liquor to release vaporous hydrogen sulfide in order to form mercury sulfide solids.

  19. Nuclear fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    Gerkey, K.S.

    1979-01-01

    An automatic apparatus for loading a predetermined amount of nuclear fuel pellets into a nuclear fuel element to be used in a nuclear reactor is described. The apparatus consists of a vibratory bed capable of supporting corrugated trays containing rows of nuclear fuel pellets and arranged in alignment with the open ends of several nuclear fuel elements. A sweep mechanism is arranged above the trays and serves to sweep the rows of fuel pellets onto the vibratory bed and into the fuel element. A length detecting system, in conjunction with a pellet stopping mechanism, is also provided to assure that a predetermined amount of nuclear fuel pellets are loaded into each fuel element

  20. A simple Cavendish experimental apparatus

    Science.gov (United States)

    Kossler, W. J.; Klein, Susann; Morrow, Dominick; Juliao, Andre

    2016-03-01

    A simple Cavendish apparatus is described that allows measurement of the gravitational constant G and makes observable the gravitational attraction between commonplace objects. The apparatus consists of a torsion balance constructed from readily available materials, including lead bricks and fishing weights ("sinkers"). A computer program is used to determine the gravitational field at the location of the small mass due to a nearby lead brick, which allows students to gain experience with numerical methods. Experimental results obtained are compatible with the accepted value of G.

  1. The nano spray dryer B-90.

    Science.gov (United States)

    Heng, Desmond; Lee, Sie Huey; Ng, Wai Kiong; Tan, Reginald B H

    2011-07-01

    Spray drying is an extremely well-established technology for the production of micro-particulate powders suited for a variety of drug delivery applications. In recent years, the rise in nanomedicine has placed increased pressure on the existing systems to produce nanoparticles in good yield and with a narrow size distribution. However, the separation and collection of nanoparticles with conventional spray dryer set ups is extremely challenging due to their typical low collection efficiency for fine particles spray drying technology is provided in this review with particular emphasis on the novel Buchi® Nano Spray Dryer B-90. Readers will appreciate the limitations of conventional spray drying technology, understand the mechanisms of the Buchi® Nano Spray Dryer B-90, and also learn about the strengths and shortcomings of the system. The Buchi® Nano Spray Dryer B-90 offers a new, simple and alternative approach for the production of nanoparticles suited for a variety of drug delivery applications.

  2. Waste Water Treatment Apparatus and Methods

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  3. Apparatus for measuring fluid flow

    Science.gov (United States)

    Smith, J.E.; Thomas, D.G.

    Flow measuring apparatus includes a support loop having strain gages mounted thereon and a drag means which is attached to one end of the support loop and which bends the sides of the support loop and induces strains in the strain gages when a flow stream impacts thereon.

  4. Flexible ultrasonic pipe inspection apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C.F.; Howard, B.D.

    1994-01-01

    Pipe crawlers, pipe inspection {open_quotes}rabbits{close_quotes} and similar vehicles are widely used for inspecting the interior surfaces of piping systems, storage tanks and process vessels for damaged or flawed structural features. This paper describes the design of a flexible, modular ultrasonic pipe inspection apparatus.

  5. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.

    1981-01-01

    A nuclear fuel loading apparatus, incorporating a microprocessor control unit, is described which automatically loads nuclear fuel pellets into dual fuel rods with a minimum of manual involvement and in a manner and sequence to ensure quality control and accuracy. (U.K.)

  6. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one... covering applied over the cork and neck areas) on wine bottles to prevent insect infestation, as a barrier...

  7. 27 CFR 25.157 - Determination of tax on bottled beer.

    Science.gov (United States)

    2010-04-01

    ... bottled beer. 25.157 Section 25.157 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Tax on Beer Determination of Tax § 25.157 Determination of tax on bottled beer. The quantities of bottled beer removed subject to tax shall be computed to...

  8. Acetaldehyde in mineral water stored in polyethylene terephthalate (PET) bottles: Odour threshold and quantification

    NARCIS (Netherlands)

    Nijssen, B.; Kamperman, T.; Jetten, J.

    1996-01-01

    The use of PET bottles for packaging soft drinks and mineral waters is still growing world wide. The production process for these bottles is improving constantly. These improvements are focussed on bottles with better barrier properties, higher inertness and higher heat stability. One of the factors

  9. Detection algorithm for glass bottle mouth defect by continuous wavelet transform based on machine vision

    Science.gov (United States)

    Qian, Jinfang; Zhang, Changjiang

    2014-11-01

    An efficient algorithm based on continuous wavelet transform combining with pre-knowledge, which can be used to detect the defect of glass bottle mouth, is proposed. Firstly, under the condition of ball integral light source, a perfect glass bottle mouth image is obtained by Japanese Computar camera through the interface of IEEE-1394b. A single threshold method based on gray level histogram is used to obtain the binary image of the glass bottle mouth. In order to efficiently suppress noise, moving average filter is employed to smooth the histogram of original glass bottle mouth image. And then continuous wavelet transform is done to accurately determine the segmentation threshold. Mathematical morphology operations are used to get normal binary bottle mouth mask. A glass bottle to be detected is moving to the detection zone by conveyor belt. Both bottle mouth image and binary image are obtained by above method. The binary image is multiplied with normal bottle mask and a region of interest is got. Four parameters (number of connected regions, coordinate of centroid position, diameter of inner cycle, and area of annular region) can be computed based on the region of interest. Glass bottle mouth detection rules are designed by above four parameters so as to accurately detect and identify the defect conditions of glass bottle. Finally, the glass bottles of Coca-Cola Company are used to verify the proposed algorithm. The experimental results show that the proposed algorithm can accurately detect the defect conditions of the glass bottles and have 98% detecting accuracy.

  10. 27 CFR 19.204 - Alternation of distilled spirits plant and taxpaid wine bottling house premises.

    Science.gov (United States)

    2010-04-01

    ... spirits plant and taxpaid wine bottling house premises. 19.204 Section 19.204 Alcohol, Tobacco Products... distilled spirits plant and taxpaid wine bottling house premises. (a) General. A proprietor of a distilled spirits plant operating a contiguous taxpaid wine bottling house desiring to alternate the use of each...

  11. Random survey of the microbial quality of bottled water in South Africa

    African Journals Online (AJOL)

    Due to the increased demand and consumption of bottled water in South Africa, there has been a growing concern about the microbiological quality of this product. Retail outlets sell local as well as imported bottled water to consumers. The microbiological quality of 10 different (8 local and 2 imported) bottled water products ...

  12. New apparatus for liquid-liquid extraction, 'emulsion flow' extractor

    International Nuclear Information System (INIS)

    Yanase, Nobuyuki; Naganawa, Hirochika; Nagano, Tetsushi; Noro, Junji

    2011-01-01

    A simple and low-cost apparatus for continuous and efficient liquid-liquid extraction, which does not need continual mechanical forces (stirring, shaking, etc.) other than solution sending, has newly been developed. This apparatus, named 'emulsion flow' extractor, is composed of a column part where an emulsified state fluid flow (emulsion flow) is generated by spraying micrometer-sized droplets of an aqueous phase into an organic phase and a phase-separating part where the emulsion flow is destabilized by means of a sudden decrease in its vertical liner velocity due to a drastic increase in cross-section area of the emulsion flow passing through. In the present study, the performance of a desktop emulsion flow extractor in the extraction of Yb(III) and U(VI) from aqueous HNO 3 solutions into isooctane containing bis(2-ethylhexyl) phosphoric acid (D2EHPA) was evaluated. The mixing efficiency of the emulsion flow extractor was found to be comparable with that of a popular liquid-liquid extractor, mixer-settler. Moreover, the emulsion flow extractor proved to have an overwhelming advantage in terms of phase-separating ability. (author)

  13. Apparatus for assembly of microelectronic devices

    Science.gov (United States)

    Okandan, Murat; Nielson, Gregory N.; Cruz-Campa, Jose Luis; Lavin, Judith Maria; Resnick, Paul J.

    2017-09-12

    An apparatus including a carrier substrate configured to move a microelectronic device. The apparatus further includes a rotatable body configured to receive the microelectronic device. Additionally, the apparatus includes a second substrate configured to receive the microelectronic device from the rotatable body.

  14. Sprays and Cartan projective connections

    Science.gov (United States)

    Saunders, D. J.

    2004-10-01

    Around 80 years ago, several authors (for instance H. Weyl, T.Y. Thomas, J. Douglas and J.H.C. Whitehead) studied the projective geometry of paths, using the methods of tensor calculus. The principal object of study was a spray, namely a homogeneous second-order differential equation, or more generally a projective equivalence class of sprays. At around the same time, E. Cartan studied the same topic from a different point of view, by imagining a projective space attached to a manifold, or, more generally, attached to a `manifold of elements'; the infinitesimal `glue' may be interpreted in modern language as a Cartan projective connection on a principal bundle. This paper describes the geometrical relationship between these two points of view.

  15. Spray calcination of nuclear wastes

    International Nuclear Information System (INIS)

    Bonner, W.F.; Blair, H.T.; Romero, L.S.

    1976-01-01

    The spray calciner is a relatively simple machine; operation is simple and is easily automated. Startup and shutdown can be performed in less than an hour. A wide variety of waste compositions and concentrations can be calcined under easily maintainable conditions. Spray calcination of all commercial fuel reprocessor high-level liquid wastes and mixed high and intermediate-level wastes have been demonstrated. Wastes have been calcined containing over 2M sodium. Thus waste generated during plant startup and shutdown can be blended with normal waste and calcined. Spray calcination of ILLW has also been demonstrated. A remotely replaceable atomizing nozzle has been developed for use in plant scale equipment. The 6 mm (0.25 inch) orifice and ceramic tip offer freedom from plugging and erosion thus nozzle replacement should be required only after several months operation. Calciner capacity of over 75 l/h (20 gal/h) has been demonstrated in pilot scale equipment. Sintered stainless steel filters are effective in deentraining over 99.9 percent of the solids that result from calcining the feedstock. Since such a small amount of radionuclides escape the calciner the volume of recycle required from the effluent treatment system is very small. The noncondensable off-gas volume is also low, less than 0.5 m 3 /min (15 scfm) for a liquid feedrate of 75 l/hr (20 gal/hr). Calcine holdup in the calciner is less than 1 kg, thus the liquid feedrate is directly relatable to calcine flowrate. The calcine produced is very fine and reactive. Successful remote operation and maintenance of a heated wall spray calciner has been demonstrated while processing actual high-level waste. During these operations radionuclide volatilization from the calciner was acceptably low. 8 figures

  16. The 2016 Thermal Spray Roadmap

    Czech Academy of Sciences Publication Activity Database

    Vardelle, A.; Moreau, Ch.; Akedo, J.; Ashrafizadeh, H.; Berndt, C. C.; Berghaus-Oberste, J.; Boulos, M.; Brogan, J.; Bourtsalas, A.C.; Dolatabadi, A.; Dorfman, M.; Eden, T.J.; Fauchais, P.; Fisher, G.; Gaertner, F.; Gindrat, M.; Henne, R.; Hyland, M.; Irissou, E.; Jordan, E.H.; Khor, K.A.; Killinger, A.; Lau, Y.C.; Li, C.-J.; Li, L.; Longtin, J.; Markocsan, N.; Masset, P.J.; Matějíček, Jiří; Mauer, G.; McDonald, A.; Mostaghimi, J.; Sampath, S.; Schiller, G.; Shinoda, K.; Smith, M.F.; Syed, A.A.; Themelis, N.J.; Toma, F.-L.; Trelles, J.P.; Vassen, R.; Vuoristo, P.

    2016-01-01

    Roč. 25, č. 8 (2016), s. 1376-1440 ISSN 1059-9630 Institutional support: RVO:61389021 Keywords : anti-wear and anti-corrosion coating s * biomedical * electronic s * energy generation * functional coating s * gas turbines * thermal spray processes Subject RIV: JK - Corrosion ; Surface Treatment of Materials Impact factor: 1.488, year: 2016 http://dx.doi.org/10.1007/s11666-016-0473-x

  17. Bacteriological Evaluation of Water Bottles Used by Nursery School ...

    African Journals Online (AJOL)

    All the eleven genera were isolated in the water bottle samples collected from Amazing Grace Nursery School, Mary Sumner Nursery School, FUTO Nursery School, IMSU Nursery School and St. Paul's International Nursery School. Absent from FSP and Alvan Nursery Schools were two genera namely Salmonella and ...

  18. Water Jets from Bottles, Buckets, Barrels, and Vases with Holes

    Science.gov (United States)

    Lopac, Vjera

    2015-01-01

    Observation of the water jets flowing from three equidistant holes on the side of a vertical cylindrical bottle is an interesting and widely used didactical experiment illustrating the laws of fluids in motion. In this paper we analyze theoretically and numerically the ranges of the stationary water jets flowing from various rotationally symmetric…

  19. infant bottle-feeding practice, agaro town, southwest ethiopia

    African Journals Online (AJOL)

    user

    total of 224 mothers who had children between the ages of 0 and 24 months were included in the study. ... extensive advertising and aggressive sale practice of .... Reasons for bottle-feeding practice. No. %. Insufficient Breast Milk. Back to work. Short duration of Maternity leave. Availability of infant formula. Adopted child.

  20. Evaluation of Microbial Quality of Bottled Water in Iran

    Directory of Open Access Journals (Sweden)

    Mahmood Alimohammadi

    2014-03-01

    Full Text Available Background: Because of population growth, limited access to fresh water resources, the need to use bottled water, controlling microbial quality of  bottled water is important. Materials and Methods: Microbiological quality of 24 brands of bottled water available in the town markets of Iran was studied Random. Samples were collected in summer and autumn, 2012. In each season, we collected two samples for each brand. In order to analyze Total coliforms, E-Coli, and HPC, MPN and Plate Count Methods were used. Data analysis was processed by SPSS software. Results: Total coliforms were 2 MPN/100CC in two brands S18 and S20. Increased HPC levels were also observed in all brands. pH level of 6% from bottled waters were higher than the standard. Average of turbidity was 0.232 and 0.228 at the autumn and summer, respectively. Conclusion: the heterotrophic microorganisms were present in 100% of the samples. Total coliforms were also found in 12% of the samples. None of the samples contained E-Coli.

  1. Microbiological quality of water processed and bottled in Zimbabwe

    African Journals Online (AJOL)

    contents of each bottle which was inverted three times to ensure suspension of any sedimented organisms. ... metabolism on triple sugar iron (TSI) afar. Bacillus species were identified from the. NA plates by subjecting the ... The BGLB containing inverted. Durham tubes to indicate gas production were incubated at 370 C ...

  2. Blue Bottle Experiment: Learning Chemistry without Knowing the Chemicals

    Science.gov (United States)

    Limpanuparb, Taweetham; Areekul, Cherprang; Montriwat, Punchalee; Rajchakit, Urawadee

    2017-01-01

    The blue bottle experiment is a popular chemical demonstration because of its simplicity and visual appeal. Most papers on the topic focus on a new formulation or a new presentation, but only a few discuss pedagogical application for a full lab session. This article describes the use of this experiment in the first session of undergraduate…

  3. Factors influencing the consumption and standards of bottled ...

    African Journals Online (AJOL)

    Thus, a number of companies and industries in Kenya and other developed countries have come up with bottled/packaged drinking water for sale to a wide range of consumers ... For majority (65%) of the consumers, taste, convenience, fashion/status, safety and potential health benefits are important considerations. Dasani ...

  4. 40 CFR 141.101 - Use of bottled water.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Use of bottled water. 141.101 Section 141.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Use of Non-Centralized Treatment Devices § 141.101...

  5. Reducing Baby Bottle Tooth Decay. A SERVE Research Brief.

    Science.gov (United States)

    Southeastern Regional Vision for Education (SERVE), Tallahassee, FL.

    This pamphlet discusses strategies for reducing baby bottle tooth decay (BBTD) among Native American children. BBTD in infants and toddlers is a painful disease characterized by extensive decay of the upper front and side teeth. It is caused by prolonged exposure of teeth to carbohydrates, such as those contained in infant formula, milk, and fruit…

  6. Potability Assessment of Selected Brands of Bottled Water in ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: This study was carried out to determine the potability of selected brands of bottled water in. Abeokuta metropolis. Water quality ... kilometer in Ogun state, Nigeria. From each brand, three samples were analyzed for physical, ..... is an essential element for good health because it transports oxygen in the blood.

  7. OLD WINE IN NEW BOTTLES: BRIDGING THE PERIPHERAL ...

    African Journals Online (AJOL)

    In sub-Saharan African countries where democracy and rule of law are proclaimed but in several circumstances not translated into practice, it appears vital to look into alternatives that can fill governance deficits. It is against this backdrop that ''Old Wine in New Bottles: Bridging the. Peripheral Gadaa Rule to the Mainstream ...

  8. Characterizing Green Fiber Bottle Prototypes Using Computed Tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano; Stolfi, Alessandro

    2017-01-01

    Due to ever increasing demand of sustainability and biodegradability, there arises a need to develop environmental friendly packaging products. Green fiber bottle is a packaging product for carbonated beverages, made out of cellulose fibers. The production process accounts for moulding paper pulp...

  9. The Bacteriological Quality assessment of some bottled water sold ...

    African Journals Online (AJOL)

    Ninety-nine (99) isolates were obtained and the completed test revealed the presence of Escherichia coli (3%) and Enterobacter species (97%). All the bottled water brands did not meet up with the standard stipulated by the Nigerian Industrial Standard for drinking water quality and the World Health Organization standard.

  10. Whispering gallery mode selection in optical bottle microresonators

    Science.gov (United States)

    Ding, Ming; Senthil Murugan, Ganapathy; Brambilla, Gilberto; Zervas, Michalis N.

    2012-02-01

    We demonstrated a method to excite selected whispering gallery modes in optical bottle microresonators (BMR) by inscribing microgroove scars on their surface by focused ion beam milling. Substantial spectral clean-up is obtained in appropriately scarred BMRs, providing the potential for high performance sensors and other optical devices.

  11. Nutritional value OF Bottle Gourd ( Lagenaria siceraria ) Seeds ...

    African Journals Online (AJOL)

    ... lipid, micro and macronutrients, and if properly utilised, could contribute in solving the problem of malnutrition and also serve as raw material for agro-based industries. Keywords: Bottle gourd seeds, seed coat, proximate analysis, minerals and Amino acid composition. Global Journal of Pure and Applied Sciences Vol.

  12. Whoosh Bottle Safety, Again: What about What Is inside?

    Science.gov (United States)

    Gregory, Robert B.; Lauber, Matthew

    2012-01-01

    Studies regarding the whoosh bottle combustion experiment have largely focused on the detonation hazard of the demonstration, particularly with regards to fuel and container choice. Previous work has suggested that the fuel should be 2-propanol owing to its relatively cool flame characteristics. The current study has found that the combustion of…

  13. Assessment of physico-chemical qualities of commercial bottled ...

    African Journals Online (AJOL)

    Two different batches of Tropix ®, Uzzi ®, Swan ®, Constant ®, Crystal ® and Ragolis ® commercial brands of bottled water were analyzed for their physicochemical quality, especially the organic and inorganic contaminants of health significances. The pH of the samples was measured using Suntex pH meter SP 701 series ...

  14. A survey of the radiological quality of Mexican bottled waters

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del R, H.; Davila R, J. I.; Rosales H, M. A.; Mireles G, F.; Pinedo V, J. L., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas (Mexico)

    2013-10-15

    More bottled drinking water is consumed per capita in Mexico than in any other country in the world. With the purpose of verifying the compliance with Mexican standards for radioactive content of drinking water, the gross alpha and beta activities were measured in 34 brands of bottled water consisting of purified water (19), natural mineral water (12), and mineralized water (3). Electrical conductivity of water samples ranged from 10 to 1465 μS/cm, and mostly high values were for the mineralized water samples. Gross alpha activities ranged from <12.2 to 709.8 mBq/L, while gross beta activities values varied from <26 to 616 mBq/L. All the bottled water samples had radioactivity content below the maximum permissible levels established in the Official Mexican Norm, except for the gross alpha level of one natural mineral water. Based upon these results it can be concluded that, in general, the analyzed bottled waters have acceptable quality with regard to radioactive content of gross alpha and beta activities. (Author)

  15. Water Flow Experiments: Single and Double Bottle Systems

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 23; Issue 1. Water Flow Experiments: Single and Double Bottle Systems ... Jain International Residential School, Jakkasandra Post, Kanakapura Road, Ramanagara Dist., Karnataka 562 112, India. Room No 425, SH-3 Ashoka University, Near Rai Police ...

  16. Microbiological quality of packaged bottled water and public water ...

    African Journals Online (AJOL)

    Bacteriological assessment of five samples of bottled water marketed in Ibadan, Nigeria and same number of public tap water supply (other wise called tap water) in Ibadan city was carried out. The samples were tested for bacterial cells counts, presumptive coliform count and the isolates were characterised using selective ...

  17. Influence of bottled water packaging attributes on consumers ...

    African Journals Online (AJOL)

    The purpose of this study was to identify the influence of bottled water packaging attributes on consumers' purchase decision. The research focused in Addis Ababa (Ethiopia). The study used color, graphic design, size, printed information and shape of packaging as independent variables and consumers' purchase ...

  18. Gourds: Bitter, Bottle, Wax, Snake, Sponge and Ridge

    Science.gov (United States)

    Minor cucurbits include bitter gourd, bottle gourd, wax gourd, snake gourd, and sponge and ridge gourd, which are significant dietary sources of nutrients such as vitamin A and C, iron and calcium. These cucurbits are cultivated and marketed by smallholder farmers and remain important components of ...

  19. Dynamically tunable optical bottles from an optical fiber

    DEFF Research Database (Denmark)

    Chen, Yuhao; Yan, Lu; Rishøj, Lars Søgaard

    2012-01-01

    Optical fibers have long been used to impose spatial coherence to shape free-space optical beams. Recent work has shown that one can use higher order fiber modes to create more exotic beam profiles. We experimentally generate optical bottles from Talbot imaging in the coherent superposition of tw...

  20. Gatrointestinal parasites associated with the stools of bottle-fed ...

    African Journals Online (AJOL)

    Gatrointestinal parasites associated with the stools of bottle-fed babies in Benin city, Nigeria. MO Okungbowa, FI Okungbowa. Abstract. No Abstract. Global Journal of Pure and Applied Sciences Vol. 13 (3) 2007: pp.415-419. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL ...

  1. Prevalence of work-related injuries among workers of bottling ...

    African Journals Online (AJOL)

    Methodology: A descriptive cross-sectional study was conducted among workers of bottling industries in Benin City, Edo State. A total of 450 respondents were selected using a multistaged sampling technique. An interviewer administered questionnaire was used for data collection. Data was collated and analysed with IBM ...

  2. A survey of the radiological quality of Mexican bottled waters

    International Nuclear Information System (INIS)

    Lopez del R, H.; Davila R, J. I.; Rosales H, M. A.; Mireles G, F.; Pinedo V, J. L.

    2013-10-01

    More bottled drinking water is consumed per capita in Mexico than in any other country in the world. With the purpose of verifying the compliance with Mexican standards for radioactive content of drinking water, the gross alpha and beta activities were measured in 34 brands of bottled water consisting of purified water (19), natural mineral water (12), and mineralized water (3). Electrical conductivity of water samples ranged from 10 to 1465 μS/cm, and mostly high values were for the mineralized water samples. Gross alpha activities ranged from <12.2 to 709.8 mBq/L, while gross beta activities values varied from <26 to 616 mBq/L. All the bottled water samples had radioactivity content below the maximum permissible levels established in the Official Mexican Norm, except for the gross alpha level of one natural mineral water. Based upon these results it can be concluded that, in general, the analyzed bottled waters have acceptable quality with regard to radioactive content of gross alpha and beta activities. (Author)

  3. Inoculation ofperitoneal dialysate fluid into blood culture bottles im ...

    African Journals Online (AJOL)

    Abstract The aiIn of the study was to detennine if direct inoculation of peritoneal fluid into Bactec blood culture bottles would improve the positive bacteriological yield compared with conventional techniques in continuous ambulatory peritoneal dialysis (CAPD) patients with peritonitis. All patients presenting with suspected ...

  4. Inoculation of peritoneal dialysate fluid into blood culture bottles ...

    African Journals Online (AJOL)

    The aim of the study was to determine if direct inoculation of peritoneal fluid into Bactec blood culture bottles would improve the positive bacteriological yield compared with conventional techniques in continuous ambulatory peritoneal dialysis (CAPD) patients with peritonitis. All patients presenting with suspected peritonitis ...

  5. Do breastfeeding and bottle feeding influence occlusal parameters?

    Science.gov (United States)

    Galán-Gónzalez, Antonio F; Aznar-Martín, Teresa; Cabrera-Domínguez, Maria E; Domínguez-Reyes, Antonia

    2014-01-01

    A study was made of the influence of breastfeeding and bottle feeding on development of the dental arches and occlusion in an infant population. In total, 298 infants (163 girls and 135 boys) were selected from a series of 1,643 preschool children in Seville, Spain, evaluating the type of feeding received after birth (breastfeeding only or bottle feeding only), the duration of such feeding, and its influence upon the parameters that define occlusion of the dental arches. The study comprised a full exploration of the stomatognathic system of the infants and a questionnaire for the parents. SPSS Statistical Package software (SPSS, Inc., Chicago, IL) was used to analyze the results. In total, 109 children were exclusively breastfed (36.6%) for an average of 6.8±5.8 months, whereas 189 children were exclusively bottle fed (63.4%) for an average of 17.99±11.5 months. On comparing the occlusal parameters of the two groups, the most beneficial effects (straight terminal plane, canine class I relationship, diastemas, and primate spaces) corresponded to the infants who were breastfed. Breastfed infants show better development of the dental arches and a lesser incidence of dental occlusion disorders than bottle-fed infants.

  6. 21 CFR 1250.42 - Water systems; constant temperature bottles.

    Science.gov (United States)

    2010-04-01

    ... and protected as to minimize the hazard of contamination of the water supply. (c) On all new or... at all times as to prevent contamination of the water. (e) Constant temperature bottles and other... subjected to effective bactericidal treatment as often as may be necessary to prevent the contamination of...

  7. Prospects for Recycling of Waste PET Bottles in Mauritius

    African Journals Online (AJOL)

    Nafiisah

    impacts of the recycling process was significantly lower that the current disposal technique. Keywords: PET bottles .... return. Prize competitions can encourage the collection of PET since money or gifts are given to the winner. ... MRF would be the creation of jobs for a number of people. 4.2 Scenario 2: Kerbside collection ...

  8. Painting Cloud Nine: A Study of Magritte's Bottle Series.

    Science.gov (United States)

    Turner, Dianne

    2000-01-01

    Provides background information on Rene Magritte and his work. Offers an activity in which elementary and middle school students can learn about Magritte's sky and silhouette series of painted wine bottles. Explains that the lesson should be used when students are learning about poetry in language arts classes. (CMK)

  9. 27 CFR 5.41 - Bottle cartons, booklets and leaflets.

    Science.gov (United States)

    2010-04-01

    ... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF DISTILLED SPIRITS Labeling... not contain any statement, design, device, or graphic, pictorial, or emblematic representation that is... (other than a shipping container) is so designed that the bottle is readily removable, it may display any...

  10. Bottle Babies: A Guide to the Baby Foods Issue. Revised.

    Science.gov (United States)

    Cottingham, Jane, Comp.

    This guide has been compiled as an aide-memoire and resource book about the increasing incidence of malnutrition in infants caused by bottle feeding in the Third World. It deals with four major interrelated issues: (1) the prevalence of protein energy malnutrition, (2) the importance of breast milk, not only in preventing malnutrition and disease…

  11. Breast feeding, bottle feeding and caries experience in children ...

    African Journals Online (AJOL)

    Objective: To determine the relationship between breast feeding, bottle feeding pattern and caries experience in young children. Methods: Children aged 6 months – 5 years from 3 randomly selected local governments in Lagos State were examined intraorally. Structured questionnaire were administered to the mothers to ...

  12. Nutritional Value of Bottle Gourd (Lagenaria siceraria) seed

    African Journals Online (AJOL)

    Abdullahi Muhammad

    Whole seeds, dehulled seeds and seed coats of bottle gourd seed (Lagenaria siceraria) were analysed for their proximate, amino acids and mineral compositions. The results of the analysis showed that, whole seed has highest content of moisture (17.5 ±. 0.21%) and ash (5.80 ± 0.83%) while dehulled had highest amount ...

  13. Management of PET plastic bottles waste through recycling Khartoum state

    International Nuclear Information System (INIS)

    Fadlalla, N. B. I.

    2010-10-01

    This study been carried out to assess the general waste management in Khartoum State and effectively manage the PET plastic bottles by identifying practical means and introducing recycling as cleaner production tool to achieve sustainable development goals. The information data were gathered during the period June-July 2010 through questionnaires, interview, meeting and visits to various sites, in addition to the official information and documents collected from reliable sources, mainly Sudan Central Bank, customs authorities, Ministry of Industry, soft drink and water bottling factories. The data were presented in tables, graphs and charts by applying windows excel program and also applying e view package for the future forecast. Analysis of data shows a rising consumption in PET bottles and the forecasted PET consumption in year 2015 estimated to be 60000 Tons, twice the estimate in the year 2010. This situation will create serious environmental problems that require much more effort to be exerted by all stake holders to book for scientific and practical solutions for the disposal of plastic waste through recycling. Based on the analysis and findings recommendations have been made that ensure on recycling of PET plastic bottles by mechanical method that depends mainly on collection, segregation, cleaning and processing. Further studies and researches on other recycling methods have been recommended in the future. (Author)

  14. An assessment of the microbiological quality of some bottle water ...

    African Journals Online (AJOL)

    A total of 40 samples comprising of 4 different brands were randomly selected using stratified sampling techniques from different sites of Kano metropolis in ... the consumer through campaign awareness can reduce level of exposure to stake holders to protect and store bottle water against sunlight exposure, chemicals and ...

  15. Spray granulation for drug formulation.

    Science.gov (United States)

    Loh, Zhi Hui; Er, Dawn Z L; Chan, Lai Wah; Liew, Celine V; Heng, Paul W S

    2011-12-01

    Granulation is a key unit process in the production of pharmaceutical solid dosage forms and involves the agglomeration of fine particles with the aid of a binding agent. Fluidized bed granulation, a classic example of spray granulation, is a technique of particle agglomeration brought about by the spray addition of the binding liquid onto a stationary bed of powder particles that is transformed to a fluid-like state by the passage of air through it. The basic working principles, equipment set-up, advantages and challenges of fluidized bed granulation are introduced in this review. This is followed by an overview of the formulation and process-related variables affecting granulation performance. Technological advances, particularly in the application of process analytical tools, in the field of fluidized bed granulation research are also discussed. Fluidized bed granulation is a popular technique for pharmaceutical production, as it is a highly economical and efficient one-pot process. The research and development of process analytical technologies (PAT) has allowed greater process understanding and control to be achieved, even for the lesser known fluidized bed techniques, such as bottom spray and fluidized hot melt granulation. In view of its consistent mixing, as well as continuous and concurrent wetting and drying occurring throughout processing, fluidized bed granulation shows great potential for continuous production although more research is required to fully implement, validate and integrate the PAT tools in a production line.

  16. Factors affecting insulin adherence to type I glass bottles

    International Nuclear Information System (INIS)

    Mitrano, F.P.; Newton, D.W.

    1982-01-01

    Some physicochemical factors that could account for insulin adherence to type I glass bottles from admixtures of insulin with 5% dextrose (D5W) and 0.9% sodium chloride (NS) injections were studied. Samples of three volumes of NS or D5W containing insulin 125 I were mixed in three sizes of bottles to test the effect of surface area and volume. Appropriate volumes of insulin were combined with insulin 125 I and D5W or NS to yield solutions containing nine concentrations of insulin to test the effect of insulin concentration. Appropriate volumes of KCl injection to yield six concentrations were combined with insulin 125 I and NS or D5W to test the effect of KCl concentration. All samples were assayed by gamma scintillation. In general, there was a direct relationship between the percentage of insulin adhering and the container surface area. In D5W admixtures, as the fill volume at constant insulin 125 I concentration was doubled and quadrupled, the adherence of insulin decreased in all three bottle sizes (200, 250, and 500 ml). In NS admixtures, however, this effect was seen only with the 250-ml bottle. Increasing insulin concentrations over the range of 50-300 units/liter in D5W and 0-50 units/liter in NS resulted in decreased adherence. The addition of 1-60 meq/liter of KCl resulted in a significant decrease of insulin adhering from D5W and an insignificant decrease from NS admixtures. The percentage of insulin adhering to type I glass surfaces may be reduced to 25% or less by preparing i.v. admixtures in full bottles of D5W or NS at insulin concentrations of 25 to 300 units/liter. The addition of KCl, when therapeutically appropriate, will further decrease the extent of insulin adherence

  17. 1994 Thermal spray industrial applications: Proceedings

    International Nuclear Information System (INIS)

    Berndt, C.C.; Sampath, S.

    1994-01-01

    The 7th National Thermal Spray Conference met on June 20--24, 1994, in Boston, Massachusetts. The conference was sponsored by the Thermal Spray Division of ASM International and co-sponsored by the American Welding Society, Deutscher Verband fur Schweisstechnik e.V., High Temperature Society of Japan, International Thermal Spray Association, and Japanese Thermal Spraying Society. The conference covered applications for automobiles, aerospace, petrochemicals, power generation, and biomedical needs. Materials included metals, ceramics, and composites with a broad range of process developments and diagnostics. Other sections included modeling and systems control; spray forming and reactive spraying; post treatment; process, structure and property relationships; mechanical properties; and testing, characterization and wear. One hundred and seventeen papers have been processed separately for inclusion on the data base

  18. Effectiveness of containment sprays in containment management

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Perez, S.E.; Lehner, J.R.

    1993-05-01

    A limited study has been performed assessing the effectiveness of containment sprays-to mitigate particular challenges which may occur during a severe accident. Certain aspects of three specific topics related to using sprays under severe accident conditions were investigated. The first was the effectiveness of sprays connected to an alternate water supple and pumping source because the actual containment spray pumps are inoperable. This situation could occur during a station blackout. The second topic concerned the adverse as well as beneficial effects of using containment sprays during severe accident scenario where the containment atmosphere contains substantial quantities of hydrogen along with steam. The third topic was the feasibility of using containment sprays to moderate the consequences of DCH

  19. High quality ceramic coatings sprayed by high efficiency hypersonic plasma spraying gun

    International Nuclear Information System (INIS)

    Zhu Sheng; Xu Binshi; Yao JiuKun

    2005-01-01

    This paper introduced the structure of the high efficiency hypersonic plasma spraying gun and the effects of hypersonic plasma jet on the sprayed particles. The optimised spraying process parameters for several ceramic powders such as Al 2 O 3 , Cr 2 O 3 , ZrO 2 , Cr 3 C 2 and Co-WC were listed. The properties and microstructure of the sprayed ceramic coatings were investigated. Nano Al 2 O 3 -TiO 2 ceramic coating sprayed by using the high efficiency hypersonic plasma spraying was also studied. Compared with the conventional air plasma spraying, high efficiency hypersonic plasma spraying improves greatly the ceramic coatings quality but at low cost. (orig.)

  20. Sustained delivery of salbutamol and beclometasone from spray-dried double emulsions.

    Science.gov (United States)

    Learoyd, Tristan P; Burrows, Jane L; French, Eddie; Seville, Peter C

    2010-01-01

    The sustained delivery of multiple agents to the lung offers potential benefits to patients. This study explores the preparation of highly respirable dual-loaded spray-dried double emulsions. Spray-dried powders were produced from water-in-oil-in-water (w/o/w) double emulsions, containing salbutamol sulphate and/or beclometasone dipropionate in varying phases. The double emulsions contained the drug release modifier polylactide co-glycolide (PLGA 50 : 50) in the intermediate organic phase of the original micro-emulsion and low molecular weight chitosan (Mwemulsion stabilizer) and leucine (aerosolization enhancer) in the tertiary aqueous phase. Following spray-drying resultant powders were physically characterized: with in vitro aerosolization performance and drug release investigated using a Multi-Stage Liquid Impinger and modified USP II dissolution apparatus, respectively. Powders generated were of a respirable size exhibiting emitted doses of over 95% and fine particle fractions of up to 60% of the total loaded dose. Sustained drug release profiles were observed during dissolution for powders containing agents in the primary aqueous and secondary organic phases of the original micro-emulsion; the burst release of agents was witnessed from the tertiary aqueous phase. The novel spray-dried emulsions from this study would be expected to deposit and display sustained release character in the lung.

  1. New apparatus of JMTR hot laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Haru Yuki; Kawa Mura, Hiro Shi [Japan Atomic Energy Research Institute, Tokai (Japan)

    1995-09-15

    In the Hot Laboratory, PIE apparatus and technology have been continuously developed and expanded to accommodate the needs of researchers. Especially from 1994 to 1995, several apparatus were extensively developed and are being installed as follows: 1)PIE equipment for beryllium examinations To measure the tritium release rate, thermal coefficient and so on of irradiated beryllium, four glove boxes and apparatus were installed. 2)Welding and machining apparatus To evaluate the weldability of fusion reactor materials, plates of SUS 316 and Inconel 625 irradiated in the JMTR were welded, machined to test pieces and then subjected to tensile test. 3)Electron beam heat load testing apparatus To perform high heat load test and thermal shock test for plasma facing materials of fusion reactor, an electron beam heating apparatus was manufactured and installed in a concrete cell. 4)Test piece manufacturing apparatus A cutting apparatus to cut the tube of in pile loop used in the JMTR, and an electro discharge machining apparatus to manufacture the test pieces were installed. 5)IASCC testing apparatus To perform the stress corrosion cracking test in high temperature water, an IASCC testing apparatus was installed and offered many useful data.

  2. Construction of shallow land simulation apparatuses

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Takebe, Shinichi; Ohnuki, Toshihiko; Ogawa, Hiromichi; Harada, Yoshikane; Saitoh, Kazuaki; Wadachi, Yoshiki

    1984-07-01

    Shallow land simulation apparatuses in which natural soil can be used as testing soil have been constructed to investigate the migration characteristics of radionuclides in a disposal site. These apparatuses consist of aerated zone apparatus and aquifer zone one. In the aerated zone apparatus, aerated soil upon ground water level is contained in the soil column (d: 30cm x h: 120cm). In the aquifer zone apparatus, aquifer soil laying ground water level is contained in the soil vessel (b: 90cm x l: 270cm x h: 45cm). This report describes the outline of shallow land simulation apparatuses : function of apparatuses and specification of devices, analysis of obstructions, safety rules, analysis of accidents and operation manual. (author)

  3. A New Bottle Design Decreases Hypoxemic Episodes during Feeding in Preterm Infants

    Directory of Open Access Journals (Sweden)

    Alejandro Jenik

    2012-01-01

    Full Text Available Oxygen saturation is lower during bottle feeding than during breastfeeding in preterm infants. Our objective was to compare two different bottle systems in healthy preterm infants before discharge in terms of SpO2 and oral feeding efficiency (rate of milk intake. Infants without supplement oxygen needs were evaluated twice on the same day during two consecutive feeds, by the same nurse. Infants served as their own controls for comparison of two systems of bottles, the order of which was randomized. The new bottle's nipple design mimics mom's breast in shape and feel, and the bottle vents to air when the child sucks on the nipple. The other system was the hospital's standard plastic bottle with silicone nipple. The rate of milk intake was calculated as the total volume transferred minus volume lost divided by time of feeding, mL/min. Thirty-four infants (BW: 1,163±479.1 g were studied at 35.4±1.3 weeks after-conception. SpO2 was significantly higher in infants fed with the new bottle design. Milk intake rate was significantly higher with the new bottle than with the standard bottle design. The new bottle design improves oral feeding performance in preterm infants near to discharge when compared to that of a standard bottle.

  4. Bottles to trees: Plastic beverage bottles as an alternative nursery growing container for reforestation in developing countries.

    Science.gov (United States)

    Khurram, Safiullah; Burney, Owen T; Morrissey, Robert C; Jacobs, Douglass F

    2017-01-01

    Reforestation is needed globally to help restore degraded sites, combat desertification, protect watersheds, and provide forest products. This involves planting forest tree seedlings grown in local nurseries, but technologies to produce quality seedlings are lacking in developing countries. Modern nursery containers used to propagate seedlings have internal-surface barriers (ribs or ridges) or side-slits to prevent root spiraling. These are cost prohibitive or unavailable in developing countries and so polybags (plastic bags) are more commonly used, despite their tendency to produce seedlings with deformed root systems that have less potential to establish on field sites. Discarded plastic bottles, which are readily available worldwide, may be a feasible alternative for seedling propagation. We conducted two experiments to assess the potential of repurposed plastic beverage bottles to grow quality trees: 1) Container Comparison-to evaluate Arizona walnut (Juglans major [Toor.] Heller) and Afghan pine (Pinus eldarica Medw.) seedling root and shoot development in two plastic bottle types compared to modern nursery containers and polybags, and 2) Bottle Modification-to examine the effects of root spiraling prevention techniques (side-slits, internal-ridges, and control) and container opacity (green, black, and clear) on Afghan pine seedling morphological attributes. Nursery growth and first-year seedling field performance were evaluated for both experiments. In experiment one, seedlings of both species had fewer spiraled roots in bottle containers compared to polybags. Arizona walnut had more fibrous root systems in polybags, while Afghan pine root system fibrosity was greatest in bottle containers. First-year field performance of both species was not affected by container type. In experiment two, less spiraled roots occurred in containers with air-slits and interior-ridges compared to the control. The effects of container opacity on seedling morphology were

  5. Bottles to trees: Plastic beverage bottles as an alternative nursery growing container for reforestation in developing countries.

    Directory of Open Access Journals (Sweden)

    Safiullah Khurram

    Full Text Available Reforestation is needed globally to help restore degraded sites, combat desertification, protect watersheds, and provide forest products. This involves planting forest tree seedlings grown in local nurseries, but technologies to produce quality seedlings are lacking in developing countries. Modern nursery containers used to propagate seedlings have internal-surface barriers (ribs or ridges or side-slits to prevent root spiraling. These are cost prohibitive or unavailable in developing countries and so polybags (plastic bags are more commonly used, despite their tendency to produce seedlings with deformed root systems that have less potential to establish on field sites. Discarded plastic bottles, which are readily available worldwide, may be a feasible alternative for seedling propagation. We conducted two experiments to assess the potential of repurposed plastic beverage bottles to grow quality trees: 1 Container Comparison-to evaluate Arizona walnut (Juglans major [Toor.] Heller and Afghan pine (Pinus eldarica Medw. seedling root and shoot development in two plastic bottle types compared to modern nursery containers and polybags, and 2 Bottle Modification-to examine the effects of root spiraling prevention techniques (side-slits, internal-ridges, and control and container opacity (green, black, and clear on Afghan pine seedling morphological attributes. Nursery growth and first-year seedling field performance were evaluated for both experiments. In experiment one, seedlings of both species had fewer spiraled roots in bottle containers compared to polybags. Arizona walnut had more fibrous root systems in polybags, while Afghan pine root system fibrosity was greatest in bottle containers. First-year field performance of both species was not affected by container type. In experiment two, less spiraled roots occurred in containers with air-slits and interior-ridges compared to the control. The effects of container opacity on seedling morphology

  6. A critical investigation into the spray-drying of hydroxyapatite powder for thermal spray applications

    OpenAIRE

    Murtaza, Qasim

    2006-01-01

    This work examines the investigation of the spray drying process of Hydroxyapatite powder (HA) used as a thermal spray deposit in the application of orthopaedic femoral implants. In this research, the Niro- Minor™ mixed spray dryer was used for both modelling and experimental studies. The process parameters investigated included HA slurry viscosity, temperature, and air flowrate. Computational Fluid Dynamic (CFD) modelling and validation of the spray drying of HA powder was performed. An anal...

  7. Synthesis gas method and apparatus

    Science.gov (United States)

    Kelly, Sean M.; Kromer, Brian R.; Litwin, Michael M.; Rosen, Lee J.; Christie, Gervase Maxwell; Wilson, Jamie R.; Kosowski, Lawrence W.; Robinson, Charles

    2013-01-08

    A method and apparatus for producing a synthesis gas product having one or more oxygen transport membrane elements thermally coupled to one or more catalytic reactors such that heat generated from the oxygen transport membrane element supplies endothermic heating requirements for steam methane reforming reactions occurring within the catalytic reactor through radiation and convention heat transfer. A hydrogen containing stream containing no more than 20 percent methane is combusted within the oxygen transport membrane element to produce the heat and a heated combustion product stream. The heated combustion product stream is combined with a reactant stream to form a combined stream that is subjected to the reforming within the catalytic reactor. The apparatus may include modules in which tubular membrane elements surround a central reactor tube.

  8. Micromachined patch-clamp apparatus

    Science.gov (United States)

    Okandan, Murat

    2012-12-04

    A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.

  9. Thermoplastic welding apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Matsen, Marc R.; Negley, Mark A.; Geren, William Preston; Miller, Robert James

    2017-03-07

    A thermoplastic welding apparatus includes a thermoplastic welding tool, at least one tooling surface in the thermoplastic welding tool, a magnetic induction coil in the thermoplastic welding tool and generally encircling the at least one tooling surface and at least one smart susceptor in the thermoplastic welding tool at the at least one tooling surface. The magnetic induction coil is adapted to generate a magnetic flux field oriented generally parallel to a plane of the at least one smart susceptor.

  10. Coated substrate apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Zhenan; Diao, Ying; Mannsfeld, Stefan Christian Bernhardt; Tee, Chee-Keong; Becerril-Garcia, Hector A.; Zhou, Yan

    2018-01-09

    A coated substrate is formed with aligned objects such as small molecules, macromolecules and nanoscale particulates, such as inorganic, organic or inorganic/organic hybrid materials. In accordance with one or more embodiments, an apparatus or method involves an applicator having at least one surface patterned with protruded or indented features, and a coated substrate including a solution-based layer of objects having features and morphology attributes arranged as a function of the protruded or indented features.

  11. Cooling apparatus and couplings therefor

    Science.gov (United States)

    Lomax, Curtis; Webbon, Bruce

    1993-11-01

    A cooling apparatus includes a container filled with a quantity of coolant fluid initially cooled to a solid phase, a cooling loop disposed between a heat load and the container. A pump for circulating a quantity of the same type of coolant fluid in a liquid phase through the cooling loop, a pair of couplings for communicating the liquid phase coolant fluid into the container in a direct interface with the solid phase coolant fluid.

  12. Apparatus for entrained coal pyrolysis

    Science.gov (United States)

    Durai-Swamy, Kandaswamy

    1982-11-16

    This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.

  13. Multipurpose Thermal Insulation Test Apparatus

    Science.gov (United States)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2002-01-01

    A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.

  14. Apparatus for making molten silicon

    Science.gov (United States)

    Levin, Harry (Inventor)

    1988-01-01

    A reactor apparatus (10) adapted for continuously producing molten, solar grade purity elemental silicon by thermal reaction of a suitable precursor gas, such as silane (SiH.sub.4), is disclosed. The reactor apparatus (10) includes an elongated reactor body (32) having graphite or carbon walls which are heated to a temperature exceeding the melting temperature of silicon. The precursor gas enters the reactor body (32) through an efficiently cooled inlet tube assembly (22) and a relatively thin carbon or graphite septum (44). The septum (44), being in contact on one side with the cooled inlet (22) and the heated interior of the reactor (32) on the other side, provides a sharp temperature gradient for the precursor gas entering the reactor (32) and renders the operation of the inlet tube assembly (22) substantially free of clogging. The precursor gas flows in the reactor (32) in a substantially smooth, substantially axial manner. Liquid silicon formed in the initial stages of the thermal reaction reacts with the graphite or carbon walls to provide a silicon carbide coating on the walls. The silicon carbide coated reactor is highly adapted for prolonged use for production of highly pure solar grade silicon. Liquid silicon (20) produced in the reactor apparatus (10) may be used directly in a Czochralski or other crystal shaping equipment.

  15. Airfoil lance apparatus for homogeneous humidification and sorbent dispersion in a gas stream

    Science.gov (United States)

    Myers, Robert B.; Yagiela, Anthony S.

    1990-12-25

    An apparatus for spraying an atomized mixture into a gas stream comprises a stream line airfoil member having a large radius leading edge and a small radius trailing edge. A nozzle assembly pierces the trailing edge of the airfoil member and is concentrically surrounded by a nacelle which directs shielding gas from the interior of the airfoil member around the nozzle assembly. Flowable medium to be atomized and atomizing gas for atomizing the medium are supplied in concentric conduits to the nozzle. A plurality of nozzles each surrounded by a nacelle are spaced along the trailing edge of the airfoil member.

  16. Bottle roll leach test for Temrezli uranium ore

    International Nuclear Information System (INIS)

    Çetin, K.; Bayrak, M.; Turan, A. İsbir; Üçgül, E.

    2014-01-01

    The bottle roll leach test is one of the dynamic leaching procedure which can meet in-situ mining needs for determining suitable working conditions and helps to simulate one of the important parameter; injection well design. In this test, the most important parameters are pulp density, acidic or basic concentration of leach solution, time and temperature. In recent years, bottle roll test is used not only for uranium but also gold, silver, copper and nickel metals where in situ leach (ISL) mining is going to be applied. For this purpose for gold and silver metal cyanide bottle roll tests and for uranium metal; acidic and basic bottle roll tests could be applied. The new leach test procedure which is held in General Directorate of Mineral Research and Exploration (MTA) of Turkey is mostly suitable for determining metal extraction conditions and recovery values in uranium containing ore bodies. The tests were conducted with samples taken from Temrezli Uranium Ore located in approximately 200 km east of Turkey’s capital, Ankara. Mining rights of Temrezli Ore is controlled 100% by Anatolia Energy Ltd. The resource estimate includes an indicated mineral resource of 10.827 Mlbs U 3 O 8 [~4160 t U] at an average grade of 1426 ppm [~1210 ppm U] and an additional inferred resource of 6.587 Mlbs of U 3 O 8 [~2530 t U] at an average grade of 904 ppm [~767 ppm U]. In accordance with the demand from Anatolia Energy bottle roll leach tests have been initiated in MTA laboratories to investigate the recovery values of low-grade uranium ore under in-situ leach conditions. Bottle roll leaching tests are performed on pulverized samples with representative lixiviant solution at ambient pressure and provide an initial evaluation of ore leachability with a rough estimate of recovery value. At the end of the tests by using 2 g/L NaHCO 3 and 0.2 g/L H 2 O 2 more than 90% of uranium can pass into leach solution in 12 days. (author)

  17. Radionuclides in some bottled mineral waters of Serbia

    International Nuclear Information System (INIS)

    Joksic, J.D.; Radenkovic, M.B.; Miljanic, S.S. . E-mail address of corresponding author: jasnaj@vin.bg.ac.yu; Joksic, J.D.)

    2005-01-01

    Radiochemical analysis of some commercial mineral bottled waters (Mivela, Karadjordje, Kopaonik, Prolom, Skadarska, Heba) was done. Concentrations of present naturally occurring radionuclides: 238 U, 234 U, 232 Th, 230 Th, 228 Th, 228 Ra and 226 Ra were determined by alpha and gamma spectrometry. Also the 234 U/ 238 U activity ratio was calculated and discussed. Uranium series disequilibria in the hydrosphere occurs due to geochemical differentiation processes resulting in different mobility of radionuclides from the same series. Bottled water samples show considerable natural variation of the 234 U/ 238 U ratios. There were found to be over one in some cases, like 3.3 for the Heba and 2 for the Prolom water. The 238 U was found to be very low in samples with high 234 U/ 238 U ratios. (author)

  18. Dimers on two types of lattices on the Klein bottle

    Science.gov (United States)

    Lu, Fuliang; Zhang, Lianzhu

    2012-12-01

    The problem of enumerating close-packed dimers, or perfect matchings, on two types of lattices (the so-called 8.8.4 and 8.8.6 lattices) embedded on the Klein bottle is considered, and we obtain the explicit expression of the number of close-packed dimers and entropy. Our results imply that 8.8.4 lattices have the same entropy under three different boundary conditions (cylindrical, toroidal and Klein bottle) and 8.8.6 lattices have the same property. This article is part of ‘Lattice models and integrability’, a special issue of Journal of Physics A: Mathematical and Theoretical in honour of F Y Wu's 80th birthday.

  19. Experimental Analysis of Spray Dryer Used in Hydroxyapatite Thermal Spray Powder

    Science.gov (United States)

    Murtaza, Q.; Stokes, J.; Ardhaoui, M.

    2012-09-01

    The spray drying process of hydroxyapatite (HA) powder used as a plasma spray powder on human hip implants was examined. The Niro-Minor mixed spray dryer was studied because it incorporates both co-current and counter-current air mixing systems. The process parameters of the spray drying were investigated: temperature, flow rate of the inlet hot air in the spray dryer, viscosity of feed/HA slurry, and responses (chamber and cyclone powder size, deposition of powder on the wall of spray dryer, and overall thermal efficiency). The statistical analysis (ANOVA test) showed that for the chamber particle size, viscosity was the most significant parameter, while for the cyclone particle size, the main effects were temperature, viscosity, and flow rate, but also their interaction effects were significant. The spray dried HA powder showed the two main shapes were a doughnut and solid sphere shape as a result of the different input.

  20. Advanced Nanoscale Coatings with Plasma Spray

    National Research Council Canada - National Science Library

    Atteridge, David

    2000-01-01

    .... A secondary research charter developed as this program proceeded was the assessment of the feasibility of using cored wire filled with WE-Co powder as a feed-stock for both plasma spray and twin-wire-arc spray (TWAS...

  1. New tools to optimise spray dryers

    NARCIS (Netherlands)

    Verschueren, M.; Straatsma, J.; Schutyser, M.A.I.; Akkerman, C.; Jong, de P.

    2007-01-01

    Spray drying is an essential unit operation for the manufacture of many products with specific powder properties. It is characterised by atomisation of a solution or suspension into droplets, followed by subsequent drying of these droplets by evaporation of water or other solvents. Spray drying is

  2. Patulin detection from Penicillia in bottled water commodity system

    OpenAIRE

    Paterson, R. R. M.; Ribeiro, Ana; Venâncio, Armando; Lima, Nelson

    2004-01-01

    Control of Mycological Contaminants of BOttled Water (COMBOW) is an EU-CRAFT project which is investigating the significance of fungi to this commodity. Some fungi produce toxins (mycotoxins). These compounds contaminate food and drink with detrimental effects on human health and economies. Mycotoxins have been reported recently in stored water and production confirmed in vitro. Patulin is a mycotoxin and has been regulated by the EU since 1 November 2003 in apple juice and ingredients. Penic...

  3. Acetic acid bacteria spoilage of bottled red wine -- a review.

    Science.gov (United States)

    Bartowsky, Eveline J; Henschke, Paul A

    2008-06-30

    Acetic acid bacteria (AAB) are ubiquitous organisms that are well adapted to sugar and ethanol rich environments. This family of Gram-positive bacteria are well known for their ability to produce acetic acid, the main constituent in vinegar. The oxidation of ethanol through acetaldehyde to acetic acid is well understood and characterised. AAB form part of the complex natural microbial flora of grapes and wine, however their presence is less desirable than the lactic acid bacteria and yeast. Even though AAB were described by Pasteur in the 1850s, wine associated AAB are still difficult to cultivate on artificial laboratory media and until more recently, their taxonomy has not been well characterised. Wine is at most risk of spoilage during production and the presence of these strictly aerobic bacteria in grape must and during wine maturation can be controlled by eliminating, or at least limiting oxygen, an essential growth factor. However, a new risk, spoilage of wine by AAB after packaging, has only recently been reported. As wine is not always sterile filtered prior to bottling, especially red wine, it often has a small resident bacterial population (wines, sealed with natural cork closures, and stored in a vertical upright position may develop spoilage by acetic acid bacteria. This spoilage is evident as a distinct deposit of bacterial biofilm in the neck of the bottle at the interface of the wine and the headspace of air, and is accompanied with vinegar, sherry, bruised apple, nutty, and solvent like off-aromas, depending on the degree of spoilage. This review focuses on the wine associated AAB species, the aroma and flavour changes in wine due to AAB metabolism, discusses the importance of oxygen ingress into the bottle and presents a hypothesis for the mechanism of spoilage of bottled red wine.

  4. Panel Board From Coconut Fibre And Pet Bottle

    Science.gov (United States)

    Ngadiman, Norhayati; Kaamin, Masiri; Abd. Kadir, Aslila; Sahat, Suhaila; Zaini, Aziza; Raihana Nor Zentan, Siti; Ain Ahmad, Nur; Amran, Wan Haizatul Aisyhah Wan

    2018-03-01

    The rate of global deforestation and its impact on the environment has led particle board manufacture to search for alternative feedstock, especially in countries where wood is less available compared to other cellulosic natural product. Based on the properties of coconut fibre and PET bottle, these two materials can be recycle as raw material for manufacture of panel board. As for this study, the coconut fibre were used as the filler and PET bottle as outer lining of the panel board. Two types of coconut fibre were used which are grinding and un-grinding coconut fibre. At first, the coconut fibre are undergoes softening, grinding, drying and sieving process, while PET bottle was cleaning, shredding, sieving before compacted using hydraulic hot press machine. There are four types of testing that been carried out which are swelling, water absorption, Modulus of Elasticity (MOE) and Modulus of Rupture (MOR). The result show the conventional board has the highest value for MOE test, so it's indicate that the conventional board is less strength from the coconut fibre board. As for water absorption test, the average water absorption of coconut fibre based panel board is less than conventional board. Overall, the coconut fibre board is better than conventional panel board because coconut fibre board are less swelling, has low water absorption, high modulus of rupture and low modulus of elasticity. Based on the finding, this coconut fibre panel board has potential as a stronger and long-lasting panel board than the conventional board in the market. Other than that, the panel also have their own aesthetic value since the recycled plastic bottle used as outer lining is colourful and giving aesthetic value.

  5. Panel Board From Coconut Fibre And Pet Bottle

    Directory of Open Access Journals (Sweden)

    Ngadiman Norhayati

    2018-01-01

    Full Text Available The rate of global deforestation and its impact on the environment has led particle board manufacture to search for alternative feedstock, especially in countries where wood is less available compared to other cellulosic natural product. Based on the properties of coconut fibre and PET bottle, these two materials can be recycle as raw material for manufacture of panel board. As for this study, the coconut fibre were used as the filler and PET bottle as outer lining of the panel board. Two types of coconut fibre were used which are grinding and un-grinding coconut fibre. At first, the coconut fibre are undergoes softening, grinding, drying and sieving process, while PET bottle was cleaning, shredding, sieving before compacted using hydraulic hot press machine. There are four types of testing that been carried out which are swelling, water absorption, Modulus of Elasticity (MOE and Modulus of Rupture (MOR. The result show the conventional board has the highest value for MOE test, so it’s indicate that the conventional board is less strength from the coconut fibre board. As for water absorption test, the average water absorption of coconut fibre based panel board is less than conventional board. Overall, the coconut fibre board is better than conventional panel board because coconut fibre board are less swelling, has low water absorption, high modulus of rupture and low modulus of elasticity. Based on the finding, this coconut fibre panel board has potential as a stronger and long-lasting panel board than the conventional board in the market. Other than that, the panel also have their own aesthetic value since the recycled plastic bottle used as outer lining is colourful and giving aesthetic value.

  6. Bottled vs. canned beer: Do they really taste different?

    OpenAIRE

    Barnett, Andrew; Velasco, Carlos; Spence, Charles

    2016-01-01

    People often say that beer tastes better from a bottle than from a can. However, one can ask how reliable this perceived difference is across consumers. And, if reliable, one can further ask whether it is a purely psychological phenomenon (associated with the influence of packaging on taste perception), or whether instead it reflects some more mundane physico-chemical interaction between the packaging material (or packing procedure/process) and the contents. Two experiments were conducted in ...

  7. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.

    2013-08-08

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  8. The erosive potential of candy sprays.

    Science.gov (United States)

    Gambon, D L; Brand, H S; Nieuw Amerongen, A V

    2009-05-23

    To determine the erosive potential of seven different commercially available candy sprays in vitro and in vivo. The erosive potential was determined in vitro by measuring the pH and neutralisable acidity. The salivary pH and flow rate were measured in healthy volunteers after administration of a single dose of candy spray. Candy sprays have an extremely low pH (1.9-2.3) and a neutralisable acidity varying between 0.8-1.6 ml of 0.25M NaOH. In vivo, candy sprays induced a short-term 3.0 to 5.8-fold increase in salivary flow rate with a concomitant drop in salivary pH to values between 4.4 and 5.8. All candy sprays tested have an erosive potential. This information is of use for clinicians counselling juvenile patients with dental erosion.

  9. Culture -independent Pathogenic Bacterial Communities in Bottled Mineral Water

    Directory of Open Access Journals (Sweden)

    Hamdy A. Hassan

    2015-08-01

    Full Text Available Bottled mineral water (BMW is an alternative to mains water and consider it to be better and safer. Access to safe BMW from the bacteria involving potential health hazard is essential to health. Cultivation-independent technique PCR-based single-strand conformation polymorphism (SSCP for genetic profiling of PCR-amplified 16S rRNA genes was performed using Com primer set targeting the 16S rRNA genes for detection of pathogenic bacteria in bottled mineral water from the final product of six factories for bottled mineral drinking water in Wadi El-natron region- Egypt. These factories use often ozone technology to treat large quantities of water because of its effectiveness in purifying and conditioning water. A total of 27 single products were isolated from the profiles by PCR re-amplification and cloning. Sequence analysis of 27 SSCP bands revealed that the 16S rRNA sequences were clustered into seven operational taxonomic units (OTUs and the compositions of the communities of the six samples were all common. The results showed that most communities from phyla Alphaproteobacteria and certainly in the Sphingomonas sp. Culture-independent approaches produced complementary information, thus generating a more accurate view for the bacterial community in the BMW, particularly in the disinfection step, as it constitutes the final barrier before BMW distribution to the consumer

  10. DETERMINATION OF PHTHALATES FROM BOTTLED WATER BY GC-MS

    Directory of Open Access Journals (Sweden)

    IRINA DUMITRAȘCU

    2012-03-01

    Full Text Available Determination of phthalates from bottled water by GC-MS. Phthalates are ubiquitous pollutants in the environment, due to their widespread use in the last years. These compounds are used principally as plasticizers, to impact flexibility, workability and durability to polymers but they can also be found in products such as paints, adhesives, inks and cosmetics. Phthalates are not chemically bounded to polymers; hence they are easily released and migrate into foods, beverages and drinking water from the packaging or bottling materials or manufacturing processes. This process accelerates as plastic products age and break down. With respect to their endocrine disrupting potential, phthalates such as benzyl butyl phthalate (BBP, di-butyl phthalate (DBP and di-isobutyl phthalate (DIBP have been found to elicit estrogenic responses in in vitro assays. It is possible that phthalates are a contributory factor to endocrine-mediated adverse effects observed in wildlife and humans over the past few decades. In this experiment we have analyzed the phthalates from different bottled waters purchased from the market. Determination by gas chromatography in combination with mass spectrometry detector (GC–MS in electronic ionization mode (EI with selected-ion monitoring (SIM acquisition method (GC–MS (EI–SIM has been carried out. Methods have been developed for both qualitative and quantitative analysis of phthalates. The base peak (m/z = 149 of all the phthalates was selected for the screening studies. The characteristic ions of each compound were chosen for quantitative studies.

  11. Feasibility study for bottled gas and LPG in Poland

    International Nuclear Information System (INIS)

    1992-04-01

    With a total population of ca. 40 million, Poland has an annual consumption of liquefied petroleum gas amounting to 180,000 tons, used by 2.5 million bottled-gas consumers. The consumer pattern is expected to change, with an increasing market for gas for industrial purposes and for heating. Distribution systems will also change to include tank installations in many sizes and transport with large tank lorries. LPG is estimated to be competitive with other forms of energy, and the market is expected to increase to up to ca. 500,000 tons per year. Restricting factors are shortage of supply and lack of approved applications, transport equipment and tank facilities. A list of existing bottle gas companies and evaluation of the technical facilities in the Polish Oil and Gas Company in Gydnia are included. Bottled gas is currently distributed under normal conditions and, market prices for LPG have remained stable in Poland. Detailed studies of the current distribution network in the Suwalki area are given. It should be possible to extend the existing distribution network. A proposal for the establishment of standard tank installations and the gas supply for the town of Augustow is presented. Considerable investments will have to be made in terminals, tank plants and transport equipment, and international oil companies are expected to play an important role in this market. The European Bank for Restructuring and Development could possibly contribute to the financing of the pipe network. (AB)

  12. Ocular injuries from pressurised bottled drinks in China.

    Science.gov (United States)

    Zhu, Lili; Lou, Dinghua

    2014-01-01

    The objective of this study is to provide a systematic review on ocular injuries induced by glass bottles containing carbonated drinks in China, which emphasised the injury circumstance and visual function loss. We performed a literature-based retrospective analysis using predetermined inclusion and exclusion criteria. Demographic characteristics of pressurised bottled drinks-related eye injuries were obtained and vision loss was calculated. A total of 26 relevant articles were found suitable for investigation of causative agent and patient demographics, of which 19 articles could be used for calculating vision loss and injury circumstance. Victims were often pertinent workers (46.0%). Most of the trauma was serious and even devastating. Final visual acuity was >10/20 in 29.2%, with severe final vision loss (carbonated drinks show severe vision loss. Relevant workers are most frequently injured, followed by inappropriate handlers or openers. Besides manufacturing standards being strictly implemented, many ocular traumas related to bottled carbonated drinks should be prevented through health education. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Chemical and microbiological properties of bottled water in Hamedan province

    Directory of Open Access Journals (Sweden)

    M Riahi Khoram

    2014-05-01

    Full Text Available Nowadays, the demand for bottled water is spiked in most countries including in Iran. Monitoring the microbial and chemical quality of bottled water is essential to guarantee the consumers’ health. The present study was aimed to examine the microbial and chemical quality of bottled water distributed in Hamedan province. For this reason during winter and summer of 2012, a total of 56 samples was collected randomly across the province. Analysis were carried out based on standard methods on chemical parameters such as pH, alkalinity, nitrate, sodium, potassium, fluoride, sulfate, phosphate, total hardness, permanent hardness as well as microbial quality of fecal coliform and total coliform. The data was analyzed by SPSS software and compared with Standard Methods of Iran and WHO. No total and fecal coliforms were detected in all samples. pH, alkalinity, nitrate, sulfate, phosphate, sodium and potassium values in all samples were in the range of approved by the Iranian Standards. Among the 56 samples, fluoride concentration in 44 samples was lower than desired maximum standard level and in 40 samples total hardness was lower than approved maximum standard limit. Although in most of the samples the mean value of the parameters were in the approved limit adopted by the Iranian and WHO regulations; however, a significant difference was observed between the measured parameters and their labeling quantity provided by the manufacture. Results revealed no significant difference between the mean value of the measured parameters obtained during winter and summer.

  14. Modified spinning top homogeneous spray apparatus for use in experimental respiratory disease studies.

    Science.gov (United States)

    Young, H W; Larson, E W; Dominik, J W

    1974-12-01

    The May spinning top generator was adapted to a modified Henderson tube for producing large aerosol particles (>4 mum) to obtain almost exclusive upper respiratory tract deposition of infectious aerosols in exposed mice. The system was installed in a biological safety cabinet to permit experimentation with pathogens. A novel mechanism utilizing parts from a machinists micrometer and the mechanical stage from a light microscope was developed for the spinning top generator as a means for precisely positioning the liquid feed needle. Aerosol light-scatter properties were continuously analyzed to provide relative measures of particle size distribution and aerosol concentration. When mice were exposed to influenza virus aerosols in which none of the virus was contained in particles with aerodynamic diameters <4 mum, essentially all of the virus was deposited in the upper respiratory tract tissues.

  15. Multispectral imaging method and apparatus

    Science.gov (United States)

    Sandison, David R.; Platzbecker, Mark R.; Vargo, Timothy D.; Lockhart, Randal R.; Descour, Michael R.; Richards-Kortum, Rebecca

    1999-01-01

    A multispectral imaging method and apparatus adapted for use in determining material properties, especially properties characteristic of abnormal non-dermal cells. A target is illuminated with a narrow band light beam. The target expresses light in response to the excitation. The expressed light is collected and the target's response at specific response wavelengths to specific excitation wavelengths is measured. From the measured multispectral response the target's properties can be determined. A sealed, remote probe and robust components can be used for cervical imaging

  16. Nitrogen fixation method and apparatus

    Science.gov (United States)

    Chen, H.L.

    1983-08-16

    A method and apparatus for achieving nitrogen fixation includes a volumetric electric discharge chamber. The volumetric discharge chamber provides an even distribution of an electron beam, and enables the chamber to be maintained at a controlled energy to pressure (E/p) ratio. An E/p ratio of from 5 to 15 kV/atm of O[sub 2]/cm promotes the formation of vibrationally excited N[sub 2]. Atomic oxygen interacts with vibrationally excited N[sub 2] at a much quicker rate than unexcited N[sub 2], greatly improving the rate at which NO is formed. 1 fig.

  17. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    Padini, F.R.

    1978-01-01

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  18. Coeliac cavity ultrasonic diagnosis apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Ando, O.; Suwaki, T.

    1983-07-05

    A coeliac cavity ultrasonic diagnosis apparatus is disclosed which includes an ultrasonic transducer or scanner portion adapted to be inserted into a coeliac cavity to effect a sector scan of an ultrasonic beam to produce an ultrasonic image of internal tissues and in which the ultrasonic oscillator on the one hand and an ultrasonic reflecting mirror and rotary disc on the other hand are relatively rotated so as to effect the sector scan of the ultrasonic beam and the rotary angle of the rotary disc is detected so as to obtain a deflecting angle of the ultrasonic beam and a display on a cathode ray tube of a precise ultrasonic picture image.

  19. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...... contributions to the theory of cluster stopping in matter as well as for practical applications requiring ultra-shallow implantation and modification of surfaces on the nanoscale. Metal clusters from the magnetron cluster source are of interest for the production of optical sensors to detect specific biological...

  20. Brucella detection in blood: comparison of the BacT/Alert standard aerobic bottle, BacT/Alert FAN aerobic bottle and BacT/Alert enhanced FAN aerobic bottle in simulated blood culture.

    Science.gov (United States)

    Sümerkan, B; Gökahmetoglu, S; Esel, D

    2001-07-01

    The objective of this study was to compare the performances of the standard aerobic bottle (StAe), FAN aerobic (FANAe) and enhanced FAN aerobic (E-FANAe) (the charcoal component of the FANAe was revised recently to improve the feasibility of Gram smear interpretation) blood culture bottles for BacT/Alert system for the detection of Brucella melitensis in simulated blood culture. Triplicate strains of eight clinical isolates of B. melitensis were studied. Each bottle was inoculated with 5 mL of freshly collected human blood at three different targeted bacterial inocula (10(1), 10(2) and 10(3) CFU/bottle). All bottles were monitored for up to 21 days or until they became positive. The results of time to detection (TTD) on the eight B. melitensis samples were as follows: at 10(1) CFU/bottle, the E-FANAe had a mean TTD significantly shorter than the StAe (48 h vs. 56.2 h, P StAe (41.2 h and 40 h vs. 45.6 h, P StAe, FANAe and E-FANAe were 96, 83 and 58%, respectively. At 10(3) CFU/bottle, the reproducibilities of StAe, FANAe and E-FANAe were 95, 95 and 91%, respectively. Positive results for the presence of bacteria in Gram smears were confirmed in 68% of StAe, 54% of FANAe and 90% of E-FANAe. In case of suspected brucellosis, the combination of one StAe bottle and one E-FANAe bottle seems to provide the highest and fastest recovery of the organism.

  1. Aromatic evolution of wine packed in virgin and recycled PET bottles.

    Science.gov (United States)

    Dombre, Clara; Rigou, Peggy; Wirth, Jérémie; Chalier, Pascale

    2015-06-01

    The evolution of the aromatic profile of a rosé wine packed in glass, virgin and recycled PET bottles was studied. Wine stored in PET and glass bottles was clearly differentiated after 5months of storage but only by a limited number of compounds. More pronounced decrease of oxygen sensitive compounds such as methionol was observed in PET bottles as well as the apparition of oxidative and ageing aroma compounds such as ethyl pyruvate, furfural or dioxanes in higher concentration. Compared to virgin PET bottles, recycled PET bottles induced slight changes favouring the presence of esters and alcohols. The chemical evolution of wine was the most important phenomenon that explains the loss of flavour rather than the sorption into PET. Because of their moderate oxygen permeability, the use of virgin PET and recycled PET bottles could be adapted for short conservation of wine but detrimental to aromatic quality if long conservation is intended. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Apparatus for incinerating hazardous waste

    Science.gov (United States)

    Chang, R.C.W.

    1994-12-20

    An apparatus is described for incinerating wastes, including an incinerator having a combustion chamber, a fluid-tight shell enclosing the combustion chamber, an afterburner, an off-gas particulate removal system and an emergency off-gas cooling system. The region between the inner surface of the shell and the outer surface of the combustion chamber forms a cavity. Air is supplied to the cavity and heated as it passes over the outer surface of the combustion chamber. Heated air is drawn from the cavity and mixed with fuel for input into the combustion chamber. The pressure in the cavity is maintained at least approximately 2.5 cm WC higher than the pressure in the combustion chamber. Gases cannot leak from the combustion chamber since the pressure outside the chamber (inside the cavity) is higher than the pressure inside the chamber. The apparatus can be used to treat any combustible wastes, including biological wastes, toxic materials, low level radioactive wastes, and mixed hazardous and low level transuranic wastes. 1 figure.

  3. Fuel cell catholyte regenerating apparatus

    International Nuclear Information System (INIS)

    Struthers, R. C.

    1985-01-01

    A catholyte regenerating apparatus for a fuel cell having a cathode section containing a catholyte solution and wherein fuel cell reaction reduces the catholyte to gas and water. The apparatus includes means to conduct partically reduced water diluted catholyte from the fuel cell and means to conduct the gas from the fuel cell to a mixing means. An absorption tower containing a volume of gas absorbing liquid solvent receives the mixed together gas and diluted catholyte from the mixing means within the absorption column, the gas is absorbed by the solvent and the gas ladened solvent and diluted catholyte are commingled. A liquid transfer means conducts gas ladened commingled. A liquid transfer means conducts gas ladened commingled solvent and electrolyte from the absorption column to an air supply means wherein air is added and commingled therewith and a stoichiometric volume of oxygen from the air is absorbed thereby. A second liquid transfer means conducts the gas ladened commingled solvent and diluted catholyte into a catalyst column wherein the oxygen and gas react to reconstitute the catholyte from which the gas was generated wna wherein the reconstituted diluted catholyte is separated from the solvent. Recirculating means conducts the solvent from the catalyst column back into the absorption column and liquid conducting means conducts the reconstituted catholyte to a holding tank preparatory for catholyte to a holding tank preparatory for recirculation through the cathode section of the fuel cell

  4. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  5. BETA (Bitter Electromagnet Testing Apparatus)

    Science.gov (United States)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  6. Nuclear reactor core servicing apparatus

    International Nuclear Information System (INIS)

    Andrea, C.

    1977-01-01

    Disclosed is an improved core servicing apparatus for a nuclear reactor of the type having a reactor vessel, a vessel head having a head penetration therethrough, a removable plug adapted to fit in the head penetration, and a core of the type having an array of elongated assemblies. The improved core servicing apparatus comprises a plurality of support columns suspended from the removable plug and extending downward toward the nuclear core, rigid support means carried by each of the support columns, and a plurality of servicing means for each of the support columns for servicing a plurality of assemblies. Each of the plurality of servicing means for each of the support columns is fixedly supported in a fixed array from the rigid support means. Means are provided for rotating the rigid support means and servicing means between condensed and expanded positions. When in the condensed position, the rigid support means and servicing means lie completely within the coextensive boundaries of the plug, and when in the expanded position, some of the rigid support means and servicing means lie without the coextensive boundaries of the plug

  7. Master-slave micromanipulator apparatus

    Science.gov (United States)

    Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.

    1999-01-01

    An apparatus based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be positioned in a remote location by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it.

  8. Stable hydrogen and oxygen isotope ratios of bottled waters of the world.

    Science.gov (United States)

    Bowen, Gabriel J; Winter, David A; Spero, Howard J; Zierenberg, Robert A; Reeder, Mathew D; Cerling, Thure E; Ehleringer, James R

    2005-01-01

    Bottled and packaged waters are an increasingly significant component of the human diet. These products are regulated at the regional, national, and international levels, and determining the authenticity of marketing and labeling claims represents a challenge to regulatory agencies. Here, we present a dataset of stable isotope ratios for bottled waters sampled worldwide, and consider potential applications of such data for regulatory, forensic and geochemical standardization applications. The hydrogen and oxygen isotope ratios of 234 samples of bottled water range from -147 per thousand to +15 per thousand and from -19.1 per thousand to +3.0 per thousand, respectively. These values fall within and span most of the normal range for meteoric waters, indicating that these commercially available products represent a source of waters for use as laboratory working standards in applications requiring standardization over a large range of isotope ratios. The measured values of bottled water samples cluster along the global meteoric water line, suggesting that bottled water isotope ratios preserve information about the water sources from which they were derived. Using the dataset, we demonstrate how bottled water isotope ratios provide evidence for substantial evaporative enrichment of water sources prior to bottling and for the marketing of waters derived from mountain and lowland sources under the same name. Comparison of bottled water isotope ratios with natural environmental water isotope ratios demonstrates that on average the isotopic composition of bottled water tends to be similar to the composition of naturally available local water sources, suggesting that in many cases bottled water need not be considered as an isotopically distinct component of the human diet. Our findings suggest that stable isotope ratios of bottled water have the power to distinguish ultimate (e.g., recharge) and proximal (e.g., reservoir) sources of bottled water and constitute a potential

  9. The consumption and recycling collection system of PET bottles: a case study of Beijing, China.

    Science.gov (United States)

    Zhang, Hua; Wen, Zong-Guo

    2014-06-01

    After studying the recycling collection system of polyethylene terephthalate (PET) bottles worldwide, the authors conducted an intercept survey in Beijing. Two separate questionnaires were issued, one questionnaire to PET bottle consumers and one to PET bottle recyclers. In this study, consumers are defined as people that consume PET-bottled beverages in their daily life. Recyclers were defined as those involved in the collection and recycling of PET bottles. These include scavengers, itinerant waste buyers, small community waste-buying depots, medium/large redemption depots, and recycling companies. In total, 580 surveys were completed, including 461 by consumers and 119 by recyclers. The authors found that consumption of PET bottles in Beijing was nearly 100,000 tonnes in 2012. Age, occupation, gender, and education were identified as significant factors linked to PET-bottled beverage consumption, while income was not a significant factor. 90% Of post-consumed PET bottles were collected by informal collectors (i.e., scavengers and itinerant waste buyers). The survey also found that nearly all PET bottles were reprocessed by small factories that were not designed with pollution control equipment, which allows them to offer higher prices for waste recyclable bottles. As Beijing is trying to build a formal recycling collection system for recyclables, subsidies should be given to the formal recycling sector rather than being charged land use fees, and attention should also be given to informal recyclers that make their living from the collection of recyclables. Informal and formal sectors may work together by employing the scavengers and itinerant waste buyers for the formal sectors. In addition to the recycling of PET bottles, concern should also be allocated to reduce consumption, especially among young people, as they, compared to other groups, have a stronger demand for PET-bottled beverages and will be the main body of society. Copyright © 2013 Elsevier Ltd

  10. Research of the Temperature and Humidity Processes in the Air Conditioning Apparatus Varying Air Ion Concentration

    Directory of Open Access Journals (Sweden)

    Marchenko V. G.

    2015-12-01

    Full Text Available To create comfortable conveniences for people in the room, we have to process the indoor air in the AC apparatus. Depending on given air parameters in the room, the air processing comprises the next steps: heating, cooling, wetting, drying. Except the compliance of the temperature and humidity parameters of air, we must control its ionic composition. Thereby, the experimental analysis of the air preparing in the AC apparatus is given in this article. Thank to that analysis, we can estimate the ionic and deionic impact on the air space in the specific processes of the air preparing. According to the results of experiments, we have identified, that the air temperature varying does not have significant effect on the ionic concentration. The ionic increasing after electric heater is not associated with air temperature. It is the consequence of the electron extrication from the surface of the heating element. Reducing ion moving the high air humidity decreases the concentration of the lightweight ions. The increasing of the ions in the spray-type air washers is explained by ballo-electric effect of spraying water drops, but not the air humidity rising.

  11. Sea Spray Generation at a Rocky Shoreline

    Science.gov (United States)

    2015-07-01

    Report 3. DATES COVERED (From - To) 6/15/2012 – 9/15/2015 4. TITLE AND SUBTITLE “Sea Spray Generation at a Rocky Shoreline ” 5a. CONTRACT...this project. The paper, “Sea Spray Generation at Rocky Shoreline ” by Ed Andreas was accepted for publication and as of July 2016 was being...13 Sea Spray Generation at a Rocky Shoreline 14 15 16 17 Edgar L Andreas 18 19 NorthWest Research Associates, Inc. 20 Lebanon, New

  12. Numerical simulation on multiphase spray cooling

    Science.gov (United States)

    Yan, Peiliang; Liu, Hong; Cai, Chang; Gao, Jiuliang; Yin, Hongchao

    2017-12-01

    The purpose of this work is using distilled water as working fluid to study the spray cooling heat transfer characteristics from non-boiling zone to boiling zone by CFD method. Simulation is performed using a Euler-Lagrangian method based on the air and liquid droplet two phase flow dynamics. The results of this simulation are in accordance with the experimental results of the laboratory. The simulation results show that the spray height is an important factor influencing the cooling characteristics. With the decrease of spray height, the heat transfer effect is enhanced.

  13. Apparatus Named after Our Academic Ancestors, III

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2014-01-01

    My academic ancestors in physics have called on me once more to tell you about the apparatus that they devised, and that many of you have used in your demonstrations and labs. This article is about apparatus named after François Arago, Heinrich Helmholtz, Leon Foucault, and James Watt.

  14. Radiation therapy apparatus having retractable beam stopper

    International Nuclear Information System (INIS)

    Coad, G.L.

    1983-01-01

    This invention relates to a radiation therapy apparatus which utilized a linear translation mechanism for positioning a beam stopper. An apparatus is described wherein the beam stopper is pivotally attached to the therapy machine with an associated drive motor in such a way that the beam stopper retracts linearly

  15. Method and apparatus for producing microspherical particles

    International Nuclear Information System (INIS)

    Egli, W.; Bailey, W.H.; Leary, D.F.; Lansley, R.J.

    1979-01-01

    This invention relates generally to a method and apparatus for producing microspherical particles and more particularly to a method and apparatus which are particularly useful in connection with the sol-gel process for the production of nuclear fuel kernels. (U.K.)

  16. The Acoustical Apparatus of Rudolph Koenig.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1992-01-01

    Discusses the history of Rudolph Koenig's contribution to the development of acoustical apparatus. Contributions include the clock fork to determine absolute acoustic frequencies, a forerunner of the oscilloscope called the manometric flame, and an acoustic interference apparatus used in the Fourier synthesis of musical sounds. (MDH)

  17. Apparatus for processing fibrous pulp material

    NARCIS (Netherlands)

    Dekker, J.C.; Bouma, H.; Mulder, F.B.M.

    2008-01-01

    The invention relates to an apparatus (1) for processing a flow of pulp comprising fibrous material, in particular pulp comprising cellulose fibres for making paper, said apparatus comprising a drum (2) having a rotational axis (R), an inlet end (3), an outlet end (4) and an inner surface, a

  18. Influence of Cold-Sprayed, Warm-Sprayed, and Plasma-Sprayed Layers Deposition on Fatigue Properties of Steel Specimens

    Czech Academy of Sciences Publication Activity Database

    Čížek, J.; Matejková, M.; Dlouhý, I.; Šiška, Filip; Kay, C.M.; Karthikeyan, J.; Kuroda, S.; Kovařík, O.; Siegl, J.; Loke, K.; Khor, K.A.

    2015-01-01

    Roč. 24, č. 5 (2015), s. 758-768 ISSN 1059-9630 Institutional support: RVO:68081723 Keywords : Cold spray * Fatigue * Grit-blast Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.568, year: 2015

  19. Large-scale sodium spray fire code validation (SOFICOV) test

    International Nuclear Information System (INIS)

    Jeppson, D.W.; Muhlestein, L.D.

    1985-01-01

    A large-scale, sodium, spray fire code validation test was performed in the HEDL 850-m 3 Containment System Test Facility (CSTF) as part of the Sodium Spray Fire Code Validation (SOFICOV) program. Six hundred fifty eight kilograms of sodium spray was sprayed in an air atmosphere for a period of 2400 s. The sodium spray droplet sizes and spray pattern distribution were estimated. The containment atmosphere temperature and pressure response, containment wall temperature response and sodium reaction rate with oxygen were measured. These results are compared to post-test predictions using SPRAY and NACOM computer codes

  20. Development of an antihydrogen trapping apparatus

    CERN Document Server

    Jenkins, Matthew James

    This thesis details the development and commissioning of the ALPHA antihydrogen trapping apparatus. It discusses the history of antimatter physics that led to and enabled the design of the apparatus. It discusses the importance of antihydrogen trapping in testing one of the basic assumptions of the Standard Model of particle physics (that of CPT invariance). It goes on to discuss the design and construction of the apparatus. Finally, it presents results that demonstrate antihydrogen formation in the new magnetic field configurations that together constitute a magnetic minimum trap for neutral antihydrogen. This is an important preliminary result for any antihydrogen trapping apparatus, and confirms that the ALPHA apparatus does present a potential route towards laser spectroscopy of antihydrogen.

  1. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  2. Assembly apparatus for nuclear reactors

    International Nuclear Information System (INIS)

    Boczek, W.

    1976-01-01

    A hoisting apparatus for assembling and operating a nuclear reactor comprises two rope drums, two gear mechanisms, and two hoisting mechanisms each with one rope for a predetermined load, a change-speed gear mechanism or shiftable gear mechanism for the selectable adjustment of various hoisting speeds for the two hoisting mechanisms, a drive connection which is provided for at least one gear mechanism and permits different distances between the said gear mechanism and the change-speed gear mechanism, a common motor for the two hoisting mechanisms, a rigid connection for the two lifting mechanisms which permits different distances between the lifting mechanisms, and a rope compensating device selectively adjustable so as to be operative or inoperative

  3. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  4. Apparatus for sampling hazardous media

    International Nuclear Information System (INIS)

    Gardner, J.F.; Showalter, T.W.

    1984-01-01

    An apparatus for sampling a hazardous medium, such as radioactive or chemical waste, selectively collects a predetermined quantity of the medium in a recess of an end-over-end rotatable valving member. This collected quantity is deposited in a receiving receptacle located in a cavity while the receiving receptacle is in a sealed relationship with a recess to prevent dusting of the sampled media outside the receiving receptacle. The receiving receptacle is removably fitted within a vehicle body which is, in turn, slidably movable upon a track within a transport tube. The receiving receptacle is transported in the vehicle body from its sample receiving position within a container for the hazardous medium to a sample retrieval position outside the medium container. The receiving receptacle may then be removed from the vehicle body, capped and taken to a laboratory for chemical analysis. (author)

  5. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  6. Development of capsule assembling apparatus

    International Nuclear Information System (INIS)

    Tayama, Yoshinobu; Kanazawa, Yoshiharu; Sozawa, Shizuo; Kawamata, Kazuo; Shizuoka, Yoshihiro; Onizawa, Satoshi; Nakagawa, Tetsuya

    2012-01-01

    The service of JMTR hot laboratory, associated with the Japan Materials Testing Reactor, was started on 1971 to examine specimens irradiated mainly in the JMTR. A wide variety of post irradiation examinations for research and development of nuclear fuels and materials are available in the JMTR hot laboratory. This laboratory has an advantage that its hot cell is connected with JMTR by a canal directly, and it is easy to transport irradiated capsule and specimens. New power ramping test for the high burn-up fuels by using the JMTR has been planed. The power ramping test using a boiling water capsule facility needs a re-capsuling of fuel rods for re-irradiation, and a modification of the facility up to about 100 GWD/t were necessary. This report introduces the new handling techniques and capsule assembling apparatus for the boiling water capsule facility. (author)

  7. Power conversion apparatus and method

    Science.gov (United States)

    Su, Gui-Jia [Knoxville, TN

    2012-02-07

    A power conversion apparatus includes an interfacing circuit that enables a current source inverter to operate from a voltage energy storage device (voltage source), such as a battery, ultracapacitor or fuel cell. The interfacing circuit, also referred to as a voltage-to-current converter, transforms the voltage source into a current source that feeds a DC current to a current source inverter. The voltage-to-current converter also provides means for controlling and maintaining a constant DC bus current that supplies the current source inverter. The voltage-to-current converter also enables the current source inverter to charge the voltage energy storage device, such as during dynamic braking of a hybrid electric vehicle, without the need of reversing the direction of the DC bus current.

  8. APPARATUS FOR LIQUID PHASE EXTRACTION

    Science.gov (United States)

    Hicks, T.R.; Lehman, H.R.; Rubin, B.

    1958-09-16

    operation is described. It comprises a tubular colunm having upper and lower enlarged terminal portions, and a constricted central section containing fluid dispersal packing. Pulsing means are coupled to the upper portion of the column. The inlet for the less dense phase is located above the inlet for the denser phase and both are positioned so that liquids enter the constricted packingfilled central section. The apparatos also includes an interfacing level control, and means fer sensing the level of the interface actuate apparatus for controlling the rate of flow of input or discharge. The outlet for the less dense phase is located in the upper packing free portion of the colunm and that of the denser phase in the lower portion.

  9. Isotope separation method and apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.L.

    1980-01-01

    A method and apparatus are specified for separating a mixture of isotopes present in a compound, preferably a gaseous compound, into two or more parts in each of which the abundances of the isotopes differ from the natural abundances of the isotopes in the compound. The invention particularly relates to carrying out a laser induced, isotopically selective conversion of gaseous molecules in such a manner as to achieve more than one stage of isotope separation along the length of the laser beam. As an example, the invention is applied to the separation of the isotopes of uranium in UF 6 , in which either the U-235 or U-238 isotope is selectively excited by means of irradiation from an infrared laser, and the selectively excited isotope converted into a product that can be recovered from UF 6 by one of a variety of methods that are described. (U.K.)

  10. Apparatuses to support photovoltaic modules

    Energy Technology Data Exchange (ETDEWEB)

    Ciasulli, John; Jones, Jason

    2017-08-22

    Methods and apparatuses to support photovoltaic ("PV") modules are described. A saddle bracket has a mounting surface to support one or more PV modules over a tube, a gusset coupled to the mounting surface, and a mounting feature coupled to the gusset to couple to the tube. A grounding washer has a first portion to couple to a support; and a second portion coupled to the first portion to provide a ground path to a PV module. A PV system has a saddle bracket; a PV module over the saddle bracket; and a grounding washer coupled to the saddle bracket and the PV module. Saddle brackets can be coupled to a torque tube at predetermined locations. PV modules can be coupled to the saddle brackets.

  11. Multileaf collimator and related apparatus

    International Nuclear Information System (INIS)

    Brown, K.J.

    1989-01-01

    In radiotherapy apparatus using a multileaf collimator, the adjustment positions of the individual leaves can be determined optically by means of a video camera which observes the leaves via a radiation transparent mirror in the beam path. In order to overcome problems of low contrast and varying object brightness, the improvement comprises adding retroreflectors to the collimator leaves whose positions are known relative to the inner edge of the respective leaf. The retroreflectors can extend along the length of the leaf or they can be small. For setting up, corresponding manually adjustable optical diaphragm leaves can be used to project an optical simulation of the treatment area onto the patient, retroreflectors being similarly located relative to the shadow-casting edge of the leaves. (author)

  12. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  13. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  14. Layered growth with bottom-spray granulation for spray deposition of drug.

    Science.gov (United States)

    Er, Dawn Z L; Liew, Celine V; Heng, Paul W S

    2009-07-30

    The gap in scientific knowledge on bottom-spray fluidized bed granulation has emphasized the need for more studies in this area. This paper comparatively studied the applicability of a modified bottom-spray process and the conventional top-spray process for the spray deposition of a micronized drug during granulation. The differences in circulation pattern, mode of growth and resultant granule properties between the two processes were highlighted. The more ordered and consistent circulation pattern of particles in a bottom-spray fluidized bed was observed to give rise to layered granule growth. This resulted in better drug content uniformity among the granule batches and within a granule batch. The processes' sensitivities to wetting and feed material characteristics were also compared and found to differ markedly. Less robustness to differing process conditions was observed for the top-spray process. The resultant bottom-spray granules formed were observed to be less porous, more spherical and had good flow properties. The bottom-spray technique can thus be potentially applied for the spray deposition of drug during granulation and was observed to be a good alternative to the conventional technique for preparing granules.

  15. Effect of Spray Parameters on the Corrosion Behavior of HVOF Sprayed WC-Co-Cr Coatings

    Science.gov (United States)

    Hong, Sheng; Wu, Yuping; Zheng, Yugui; Wang, Bo; Gao, Wenwen; Li, Gaiye; Ying, Guobing; Lin, Jinran

    2014-04-01

    WC-10Co-4Cr cermet coatings were deposited on the substrate of AISI 1045 steel by using high-velocity oxygen-fuel (HVOF) thermal spraying process. The Taguchi method including the signal-to-noise (S/N) ratio and the analysis of variance (ANOVA) was employed to optimize the porosity and, in turn, the corrosion resistance of the coatings. The spray parameters evaluated in this study were spray distance, oxygen flow, and kerosene flow. The results indicated that the important sequence of spray parameters on the porosity of the coatings was spray distance > oxygen flow > kerosene flow, and the spray distance was the only significant factor. The optimum spraying condition was 300 mm for the spray distance, 1900 scfh for the oxygen flow, and 6.0 gph for the kerosene flow. The results showed the significant influence of the microstructure on the corrosion resistance of the coatings. Potentiodynamic polarization and electrochemical impendence spectroscopy (EIS) results showed that the WC-10Co-4Cr cermet coating obtained by the optimum spraying condition with the lowest porosity exhibits the best corrosion resistance and seems to be an alternative to hard chromium coating.

  16. Influence of spray parameters on the microstructure and mechanical properties of gas-tunnel plasma sprayed hydroxyapatite coatings

    International Nuclear Information System (INIS)

    Morks, M.F.; Kobayashi, Akira

    2007-01-01

    For biomedical applications, hydroxyapatite (HA) coatings were deposited on 304 stainless steel substrate by using a gas tunnel type plasma spraying process. The influences of spraying distances and plasma arc currents on the microstructure, hardness and adhesion properties of HA coatings were investigated. Microstructure observation by SEM showed that HA coatings sprayed at low plasma power have a porous structure and poor hardness. HA coatings sprayed at high plasma power and short spraying distance are characterized by good adhesion and low porosity with dense structure. Hardness increased for HA coatings sprayed at shorter spraying distance and higher plasma power, mainly due to the formation of dense coatings

  17. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... bleeding by a high frequency electric current. (b) Classification. Class II. ... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  18. Hybrid radio-frequency/direct-current plasma-enhanced chemical vapor deposition system for deposition on inner surfaces of polyethylene terephthalate bottles

    Science.gov (United States)

    Li, Jing; Tian, Xiubo; Gong, Chunzhi; Yang, Shiqin; Fu, Ricky K. Y.; Chu, Paul K.

    2009-12-01

    A hybrid radio-frequency (rf)/direct-current (dc) system has been developed to control the biasing effects during deposition of diamondlike carbon (DLC) films onto the inner wall of polyethylene terephthalate (PET) bottles. An additional dc bias is coupled to the rf electrode to produce the effect of equivalent rf self-biasing. This allows more flexible control of the deposition of the DLC films which are intended to improve the gas barrier characteristics. The experimental results demonstrate that the additional dc bias improves the adhesion strength between the DLC film and PET, although the enhancement in the gas barrier properties is not significantly larger compared to the one without dc bias. The apparatus and methodology have practical importance in the food and beverage industry.

  19. Plasma spray technology process parameters and applications

    International Nuclear Information System (INIS)

    Sreekumar, K.P.; Karthikeyan, J.; Ananthapadmanabhan, P.V.; Venkatramani, N.; Chatterjee, U.K.

    1991-01-01

    The current trend in the structural design philosophy is based on the use of substrate with the necessary mechanical properties and a thin coating to exhibit surface properties. Plasma spray process is a versatile surface coating technique which finds extensive application in meeting advance technologies. This report describes the plasma spray technique and its use in developing coatings for various applications. The spray system is desribed in detail including the different variables such as power input to the torch, gas flow rate, powder properties, powder injection, etc. and their interrelation in deciding the quality of the coating. A brief write-up on the various plasma spray coatings developed for different applications is also included. (author). 15 refs., 15 figs., 2 tabs

  20. Water Reclamation using Spray Drying, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This purpose of this project is to develop a spray drying prototype to for the recovery and recycle of water from concentrated waste water recovery system brine....

  1. Water Reclamation using Spray Drying Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a new spray drying technology for the recovery and recycle of water while stabilizing the solid wastes or residues as found in advanced life support...

  2. Plasma-Sprayed Photocatalytic Zinc Oxide Coatings

    Science.gov (United States)

    Navidpour, A. H.; Kalantari, Y.; Salehi, M.; Salimijazi, H. R.; Amirnasr, M.; Rismanchian, M.; Azarpour Siahkali, M.

    2017-04-01

    Fabrication of semiconductor coatings with photocatalytic action for photodegradation of organic pollutants is highly desirable. In this research, pure zinc oxide, which is well known for its promising photocatalytic activity, was deposited on stainless-steel plates by plasma spraying. The phase composition and microstructure of the deposited films were studied by x-ray diffraction analysis and scanning electron microscopy, respectively. Despite the low-energy conditions of the plasma spraying process, the zinc oxide coatings showed good mechanical integrity on the substrate. Their photocatalytic activity was evaluated using aqueous solution of methylene blue at concentration of 5 mg L-1. The results showed the potential of the plasma spraying technique to deposit zinc oxide coatings with photocatalytic action under ultraviolet illumination. Ultraviolet-visible (UV-Vis) diffuse reflectance spectroscopy confirmed that the plasma spraying method could deposit zinc oxide films with higher photoabsorption ability relative to the initial powder.

  3. Properties of Plasma and HVOF Sprayed Coatings

    Directory of Open Access Journals (Sweden)

    Wojciech Żórawski

    2012-11-01

    Full Text Available The work compares the properties of plasma and HVOF thermally sprayed coatings obtained by blending the NiCrBSi and Fe2O3 powders. The deposition was performed by means of the Plancer PN-120 and the Diamond Jet guns for plasma spraying and HVOF spraying respectively. The SEM (EDS method was employed to study the microstructure of the produced coatings. Although the blended powders differ in particle size, shape, and distribution, it is possible to obtain composite coatings with an NiCrBSi matrix containing iron oxides. Except for a different microstructure, plasma and HVOF coatings have a different phase composition, which was examined using the Bruker D-8 Advance diffractometer. Studies of the coatings wear and scuffing resistance showed that an optimal content of Fe2O3 is about 26 % for plasma sprayed coatings and 22.5 % for HVOF deposited coatings.

  4. Ventilation Guidance for Spray Polyurethane Foam Application

    Science.gov (United States)

    Properly designed ventilation can reduce airborne levels of aerosols, mists, and vapors generated during spray application and can help protect SPF applicators, helpers, and others who may be working in adjacent areas.

  5. Water Reclamation using Spray Drying, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a new spray drying technology for the recovery and recycle of water while stabilizing the solid wastes or residues as found in advanced life support...

  6. Physics of the fire piston and the fog bottle

    International Nuclear Information System (INIS)

    Gueemez, J; Fiolhais, C; Fiolhais, M

    2007-01-01

    We analyse two irreversible adiabatic processes occurring in two thermodynamical devices: the fire piston and the 'fog bottle'. In the first, an abrupt adiabatic compression of air inside a piston causes the burning of a small paper piece, since the final temperature reaches around 750 K. In the second, an abrupt adiabatic expansion of a gas at high pressure leads to a temperature decrease with condensation of water vapour and fog formation. We show that, if the two processes were carried out reversibly, the final temperature would always be lower than that in the irreversible processes

  7. Bottled vs. Canned Beer: Do They Really Taste Different?

    Directory of Open Access Journals (Sweden)

    Andrew Barnett

    2016-09-01

    Full Text Available People often say that beer tastes better from a bottle than from a can. However, one can ask how reliable this perceived difference is across consumers. And, if reliable, one can further ask whether it is a purely psychological phenomenon (associated with the influence of packaging on taste perception, or whether instead it reflects some more mundane physico-chemical interaction between the packaging material (or packing procedure/process and the contents. Two experiments were conducted in order to address these questions. In the main experiment, 151 participants at the 2016 Edinburgh Science Festival were served a special ‘craft beer’ in a plastic cup. The beer was either poured from a bottle or can (a between-participants experimental design was used. The participants were encouraged to pick up the packaging in order to inspect the label before tasting the beer. The participants rated the perceived taste, quality, and freshness of the beer, as well as their likelihood of purchase, and estimated the price. All of the beer came from the same batch (specifically a Session IPA from Barney’s Brewery in Edinburgh. None of the participants were familiar with this particular craft brew. Nevertheless, those who evaluated the beer from the bottle rated it as tasting better than those who rated the beer served from the can. Having demonstrated such a perceptual difference (in terms of taste, we then went on to investigate whether people would prefer one packaging format over the other when the beer from bottle and can was served blind to a new group of participants (i.e., when the participants did not know the packaging material. The participants in this control study (n = 29 were asked which beer they preferred. Alternatively, they could state that the two samples tasted the same. No sign of a consistent preference was obtained under such blind tasting conditions. Explanations for the psychological impact of the packaging format, in terms of

  8. Bottle gourd rootstock-grafting promotes photosynthesis by regulating the stomata and non-stomata performances in leaves of watermelon seedlings under NaCl stress.

    Science.gov (United States)

    Yang, Yanjuan; Yu, Li; Wang, Liping; Guo, Shirong

    2015-08-15

    Previously, we found that the amelioration of photosynthetic capacity by bottle gourd (Lagenaria siceraria Standl.) rootstock in watermelon seedlings (Citrullus lanatus [Thunb.] Mansf.) with salt treatment might be closely related to the enzymes in Calvin cycle such as ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) (Yang et al., 2012). We confirmed this and showed more details in this study that improved photosynthesis of watermelon plants by bottle gourd rootstock was associated with the decreased stomata resistance and the increased photochemical activity and photosynthetic metabolism with or without 100mM NaCl stress for 3 days. The analysis of gas exchange parameters showed that self-grafted plants suffered serious non-stomatal limitation to photosynthesis under salt stress while rootstock-grafted plants were mainly affected by stomata limitation in stress conditions. Further, results showed that NaCl stress markedly reduced the chlorophyll content, damaged the structure of photosynthetic apparatus, and inhibited photochemical activity and CO2 assimilation in self-grafted plants. In contrast, rootstock-grafting increased the chlorophyll content, especially chlorophyll b, and minimized the harmful effects on photosystem II (PSII) reaction center and the thylakoids structure induced by NaCl stress. Furthermore, rootstock-grafting enhanced the content and activity of Rubisco and thus elevated carbon fixation in the leaves of watermelon scions under salt stress. The gene expressions of enzymes related to ribulose-1,5-bisphosphate (RuBP) regeneration were also up-regulated by rootstock and this probably guaranteed the sufficient supply of RuBP for the operation of Calvin cycle in watermelon scions under salt stress. Thus, bottle gourd rootstock promoted photosynthesis by the activation of stomatal and non-stomatal abilities, especially the regulation of a variety of photosynthetic enzymes, including Rubisco in grafted watermelon plants under NaCl stress

  9. Plasma sprayed coatings on crankshaft used steels

    Science.gov (United States)

    Mahu, G.; Munteanu, C.; Istrate, B.; Benchea, M.

    2017-08-01

    Plasma spray coatings may be an alternative to conventional heat treatment of main journals and crankpins of the crankshaft. The applications of plasma coatings are various and present multiple advantages compared to electric arc wire spraying or flame spraying. The study examines the layers sprayed with the following powders: Cr3C2- 25(Ni 20Cr), Al2O3- 13TiO2, Cr2O3-SiO2- TiO2 on the surface of steels used in the construction of a crankshaft (C45). The plasma spray coatings were made with the Spray wizard 9MCE facility at atmospheric pressure. The samples were analyzed in terms of micro and morphological using optical microscopy, scanning electron microscopy and X-ray diffraction. Wear tests on samples that have undergone simulates extreme working conditions of the crankshafts. In order to emphasize adherence to the base material sprayed layer, were carried out tests of microscratches and micro-indentation. Results have showed a relatively compact morphological aspect given by the successive coatings with splat-like specific structures. Following the microscratch analysis it can be concluded that Al2O3-13TiO2 coating has a higher purpose in terms of hardness compared to Cr3C2-(Ni 20Cr) and Cr2O3-SiO2- TiO2 powders. Thermal coatings of the deposited powders have increased the mechanical properties of the material. The results stand to confirm that plasma sprayed Al2O3-13TiO2 powder is in fact a efficient solution for preventing mechanical wear, even with a faulty lubrication system.

  10. Cannabis; adverse effects from an oromucosal spray.

    Science.gov (United States)

    Scully, C

    2007-09-22

    An oromucosal spray has been developed from the major components of marijuana (cannabis), including tetrahydrocannabinol (THC) and cannabidiol (CBD), in alcohol with a peppermint flavouring, designed to be administered as a spray under the tongue or on the buccal mucosa to relieve pain in multiple sclerosis. Although the available evidence indicates its efficacy in this respect, some patients develop oral burning sensation, stinging or white lesions, probably burns. To investigate the oral side-effects of oromucosal cannabis spray in multiple sclerosis (MS) patients. A small open observational study. A series of nine patients with MS who had been using a marijuana oromucosal spray for at least four weeks, were asked to attend for oral examination. Patients were asked whether they had ever experienced symptoms (dryness; bad taste; stinging) associated with use of the spray. A standard oral examination was carried out using a dental light, and the presence of any mucosal lesions recorded. Where mucosal lesions were present, patients were advised to discontinue the spray and re-attend after four weeks for re-examination. For ethical reasons, biopsies were not undertaken at the first visit. Of nine patients invited to participate, eight attended. All admitted to a stinging sensation on using the oromucosal cannabis spray, and four had visible oral mucosal white lesions in the floor of the mouth. Although the white lesions observed were almost certainly burns, resolving or improving on discontinuation of use of the medication, the high alcohol concentration of the oromucosal cannabis spray raises concern in relation to chronic oral use.

  11. Hazard Analysis for In Tank Spray Leaks

    International Nuclear Information System (INIS)

    GRAMS, W.H.

    2000-01-01

    The River Protection Project (RPP) Authorization Basis (AB) contains controls that address spray leaks in tanks. However, there are no hazardous conditions in the Hazards Database that specifically identify in-tank spray leak scenarios. The purpose of this Hazards Evaluation is to develop hazardous conditions related to in-tank spray leaks for the Hazards Database and to provide more complete coverage of Tank Farm facilities. Currently, the in-tank spray leak is part of the ''Spray Leak in Structures or From Waste Transfer Lines'' accidents in Section 3.4.2.9 of the Final Safety Analysis Report (FSAR) (CHG, 2000a). The accident analysis for the ''Spray Leak in Structure or From Waste Transfer Lines'' states the following regarding the location of a possible spray leak: Inside ventilated waste storage tanks (DSTs, DCRTs, and some SSTs). Aerosols could be generated inside a storage tank during a transfer because of a leak from the portion of the transfer pipe inside the tank. The tank ventilation system could help disperse the aerosols to the atmosphere should the vent system HEPA filters fail. This Hazards Evaluation also evaluates the controls currently assigned to the spray leak in structure accident and determines the applicability of the controls to the new hazardous conditions. This comparison reviews both the analysis in the FSAR and the controls found in the Technical Safety Requirements (TSRs) (CHG, 2000h). If the new hazardous conditions do not match the analyzed accident conditions and controls, then additional analysis may be required. This document is not intended to authorize the activity or determine the adequacy of controls; it is only intended to provide information about the hazardous conditions associated with this activity. The Control decision process as defined in the AB will be used to determine the adequacy of controls and whether the proposed activity is within the AB. This hazard evaluation does not constitute an accident analysis

  12. Automatic targeting of plasma spray gun

    International Nuclear Information System (INIS)

    Abbatiello, L.A.; Neal, R.E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is described. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun

  13. Fine Sprays for Disinfection within Healthcare

    Directory of Open Access Journals (Sweden)

    G Nasr

    2016-09-01

    Full Text Available Problems exist worldwide with Hospital Acquired Infections (HAI's. The Spray Research Group (SRG have been working with relevant industries in developing a product which can provide a delivery system for treatment chemicals for surfaces, including the design and testing of a novel Spill-Return Atomiser (SRA for this purpose. A comprehensive description of this atomiser has already been given. This paper reports on a new application of this atomiser and discusses the problem of spray coating for disinfection that has been considered very little in previous work. The related spray coating performance tests in developing the product are thus provided. The experimental work includes determining the required spray duration and the coverage area produced by different sprays, including the analysis of the effects of atomiser positions, configurations, and the required number of atomisers. Comparison is made with the efficacy of an ultrasonic gas atomiser that is currently used for this purpose. The investigation has found that the utilisation of fine sprays (10μm>D32>25μm at high liquid pressure (<12MPa and low flow rates (<0.3 l/min is suitable for surface disinfection in healthcare applications (i.e. MRSA, VRSA etc.

  14. Some mineral profiles of fresh and bottled palm wine – a ...

    African Journals Online (AJOL)

    Some mineral profiles of fresh palm wine and those of seven brands of bottled palm wine were analysed using atomic absorption spectroscopy and the values were compared. Three of the bottled samples contained toxic levels of either Pb or Cd or both. Neither metal was detected in fresh palm wine. Zn, Cr and Ni were 2 to ...

  15. Head Start Combats Baby Bottle Tooth Decay Among Native American Families.

    Science.gov (United States)

    Phillips, Margaret G.; Stubbs, Phyllis E.

    1987-01-01

    Presents current developments concerning nursing bottle caries--"baby bottle tooth decay"--and spotlights a program funded by Head Start to reduce the prevalence of these painful and disfiguring, but preventable, children's dental diseases among American Indians and Alaska Native families. (Author/BB)

  16. Green Fiber Bottle: Towards a Sustainable Package and a Manufacturing Process

    DEFF Research Database (Denmark)

    Didone, Mattia; Tosello, Guido; Kirilov, Kiril

    The Green Fiber Bottle is a fully biodegradable bottle made from molded paper pulp, which is a renewable resource. Its development depends on the development of the manufacturing technology. Impulse drying, an innovative way of drying, and FORMCELL, a method to speed the mold reconfiguration, have...

  17. Regulation and Education: Strategies for Solving the Bottle Feeding Problem. Monograph Series No. 4.

    Science.gov (United States)

    Greiner, Ted

    This book is the fourth monograph in the Cornell International Monograph Series, the second in the series to deal with the question of breast versus bottle feeding. The introduction to the monograph discusses the shift from breast to bottle feeding in both industrialized and developing nations. Some of the reasons for, and consequences of, the…

  18. The Dynamic Density Bottle: A Make-and-Take, Guided Inquiry Activity on Density

    Science.gov (United States)

    Kuntzleman, Thomas S.

    2015-01-01

    An activity is described wherein students observe dynamic floating and sinking behavior of plastic pieces in various liquids. The liquids and solids are all contained within a plastic bottle; the entire assembly is called a "density bottle". After completing a series of experiments that guides students to think about the relative…

  19. Exploring the Gas Chemistry of Old Submarine Technologies Using Plastic Bottles as Reaction Vessels and Models

    Science.gov (United States)

    Horikoshi, Ryo; Takeiri, Fumitaka; Kobayashi, Yoji; Kageyama, Hiroshi

    2016-01-01

    We describe an activity that is suitable for high school students and makes use of plastic bottles. This activity allows students to familiarize themselves with gas chemistry by introducing technologies that were applied in old submarine systems. Plastic bottles, which are representative of submarines, are used as reaction vessels. Three simple…

  20. Temporal variation of microbiological and chemical quality of noncarbonated bottled drinking water sold in Sri Lanka.

    Science.gov (United States)

    Herath, A T; Abayasekara, C L; Chandrajith, Rohana; Adikaram, N K B

    2012-03-01

    Use of bottled water in Sri Lanka has increased over the last decade, while new brands of bottled water are often introduced to the market. However, the manufacturers' adherence to bottled water regulations is questionable, raising concerns regarding the quality of bottled water. The objective of the current study was to investigate the microbiological and chemical quality of bottled water in Sri Lanka. Thirty bottled water brands were sampled and their chemical and microbiological parameters were analyzed. Microbiological analysis was carried out within 1 to 3, 3 to 6, 6 to 9, and 9 to 12 mo after the date of manufacture. The results indicated that 63% of brands tested exceeded the levels permitted by the Sri Lanka Standards Institution (SLSI) for presumptive total coliforms (TC) (ammonia. The results of this study show the need for the bottling industry to be monitored closely by relevant authorities, in order to provide safe bottled drinking water to consumers in Sri Lanka. © 2012 Institute of Food Technologists®

  1. 10 CFR 431.292 - Definitions concerning refrigerated bottled or canned beverage vending machines.

    Science.gov (United States)

    2010-01-01

    ... beverage vending machines. 431.292 Section 431.292 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY... Vending Machines § 431.292 Definitions concerning refrigerated bottled or canned beverage vending machines. Basic model means, with respect to refrigerated bottled or canned beverage vending machines, all units...

  2. Effect of chemical preservation on the shelf-life of bottled ...

    African Journals Online (AJOL)

    Six samples of bottled intermediate moisture tomato paste were stored at ambient conditions (33-38°C). Four of the samples were preserved with chemicals. One of the last two samples which was bottled with no chemical preservatives added had palm oil filled onto its headspace. Shelf-like studies conducted for forty weeks ...

  3. 27 CFR 19.384 - Preparation of bottling or packaging record.

    Science.gov (United States)

    2010-04-01

    ... packaging record. 19.384 Section 19.384 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Than Denaturation and Manufacture of Articles Bottling, Packaging, and Removal of Products § 19.384 Preparation of bottling or packaging record. The proprietor shall prepare a record for each batch of spirits...

  4. Migration of bisphenol A into water from polycarbonate baby bottles during microwave heating

    NARCIS (Netherlands)

    Ehlert, K.A.; Beumer, C.W.E.; Groot, M.C.E.

    2008-01-01

    A comprehensive migration database was established for bisphenol A from polycarbonate baby bottles into water during exposure to microwave heating. Eighteen different brands of polycarbonate baby bottles sold in Europe were collected. Initial residual content of bisphenol A and migration after

  5. suitability of broken bottles as fine aggregate for production of concrete

    African Journals Online (AJOL)

    user

    The use of broken bottles as partial replacement of river sand for production of concrete was ... material made up of cement, aggregates (fine ... as waste. Their use will reduce the nuisance they cause to man. It is therefore necessary to conduct researches on broken bottles with the view to finding ways they can be useful to ...

  6. Bottle-Neck Feature Extraction Structures for Multilingual Training and Porting (Pub Version, Open Access)

    Science.gov (United States)

    2016-05-03

    resourced Languages, SLTU 2016, 9-12 May 2016, Yogyakarta, Indonesia Bottle-Neck Feature Extraction Structures for Multilingual Training and Porting...SBN) feature extraction is a crucial part of modern automatic speech recognition (ASR) systems. The SBN network traditionally contains a hidden...2016. Keywords: DNN topology; Stacked Bottle-Neck; feature extraction ; multilingual training; system porting 1. Introduction One of the recent

  7. 75 FR 14607 - Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli

    Science.gov (United States)

    2010-03-26

    ...] Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli; Availability AGENCY: Food and... the availability of a guidance for industry entitled ``Bottled Water: Total Coliform and E. coli... determine whether any of the coliform organisms are Escherichia coli (E. coli), an indicator of fecal...

  8. Random survey of the microbial quality of bottled water in South Africa

    African Journals Online (AJOL)

    Total and faecal coliform bacteria, enterococci, C. perfringens, bacteriophages or enteric viruses were not detected in any of the ten bottled water samples analysed. It can be concluded that the microbial quality of eight of the ten selected bottled water samples analysed was within the acceptable limits set by the SABS ...

  9. Creep of plasma sprayed zirconia

    Science.gov (United States)

    Firestone, R. F.; Logan, W. R.; Adams, J. W.

    1982-01-01

    Specimens of plasma-sprayed zirconia thermal barrier coatings with three different porosities and different initial particle sizes were deformed in compression at initial loads of 1000, 2000, and 3500 psi and temperatures of 1100 C, 1250 C, and 1400 C. The coatings were stabilized with lime, magnesia, and two different concentrations of yttria. Creep began as soon as the load was applied and continued at a constantly decreasing rate until the load was removed. Temperature and stabilization had a pronounced effect on creep rate. The creep rate for 20% Y2O3-80% ZrO2 was 1/3 to 1/2 that of 8% Y2O3-92% ZrO2. Both magnesia and calcia stabilized ZrO2 crept at a rate 5 to 10 times that of the 20% Y2O3 material. A near proportionality between creep rate and applied stress was observed. The rate controlling process appeared to be thermally activated, with an activation energy of approximately 100 cal/gm mole K. Creep deformation was due to cracking and particle sliding.

  10. Experimental characterisation of Polyethylene Terephthalate (PET) bottle Eco-bricks

    International Nuclear Information System (INIS)

    Taaffe, Jonathan; O’Sullivan, Seán; Rahman, Muhammad Ekhlasur; Pakrashi, Vikram

    2014-01-01

    Highlights: • Characterisation of a novel “Eco-brick” by recycling PET bottles and plastic waste. • Eco-bricks have properties for possible uses in construction. • Consistent manufacturing of Eco-bricks demonstrated to be possible. • Weight of Eco-bricks has a nearly linear relationship with mechanical strength. • Light passage and sound reduction potential of Eco-bricks shown to be good. - Abstract: This paper addresses the issue of recycling waste plastic by considering the feasibility of use of Eco-bricks for constructional purposes. The Eco-bricks are formed by packing plastic within Polyethylene Terephthalate (PET) bottles. Guidelines were provided for the construction of Eco-bricks. Experiments were carried out to characterise some of the properties of these bricks. Compression test, sound insulation assessment and light transmission were considered in this regard and compared with traditional construction materials and conditions. Possible applications of Eco-bricks were discussed. The paper presents the first attempt to characterise these bricks and the results encourage future use of them to a significantly wider extent and for various purposes

  11. Nitrogen removal using recycled polystyrene bottles as biofilm media

    Science.gov (United States)

    Ahn, Kyu-Hong; Hwang, Jong-Hyuk; Song, Kyung-Guen; Jung, Yong-Ho; Cho, Eul-Saeng; Lim, Byung-Ran; Kim, Kwang-Soo

    2004-04-01

    The performance of an attached growth wastewater treatment process was investigated in an effort to improve nitrogen removal efficiency. Recycled Yakult (lactic acid fermentation drink) bottles made of polystyrene were used as a biofilm media. The use of Yakult bottles as a biofilm media has been attempted by numerous researchers in Japan for the removal of solids and organics. However, these studies focused only on the removal of solids and organics. This study extended their application to the removal of nitrogen for domestic sewage treatment. Yakult media was placed in a reactor with 70% apparent reactor volume in a conventional A/O process. The bottom of the Yakult media was removed, and randomly filled Yakult media were effectively able to reduce the flow in tanks, resulting in an increase in the contact time between pollutants and microorganisms. With higher HRT, the nitrogen removal efficiency was increased by up to 83% with 12 hr of HRT. Nitrification appeared to be the limiting factor of nitrogen removal at an HRT that is less than 12 hr, indicating that the Yakult process requires more retention time to achieve nitrification compared to other biofilm processes. The removal efficiencies of organics and solids were high regardless of the change of operational parameters.

  12. Assessment of Drinking Water Quality from Bottled Water Coolers.

    Science.gov (United States)

    Farhadkhani, Marzieh; Nikaeen, Mahnaz; Akbari Adergani, Behrouz; Hatamzadeh, Maryam; Nabavi, Bibi Fatemeh; Hassanzadeh, Akbar

    2014-05-01

    Drinking water quality can be deteriorated by microbial and toxic chemicals during transport, storage and handling before using by the consumer. This study was conducted to evaluate the microbial and physicochemical quality of drinking water from bottled water coolers. A total of 64 water samples, over a 5-month period in 2012-2013, were collected from free standing bottled water coolers and water taps in Isfahan. Water samples were analyzed for heterotrophic plate count (HPC), temperature, pH, residual chlorine, turbidity, electrical conductivity (EC) and total organic carbon (TOC). Identification of predominant bacteria was also performed by sequence analysis of 16S rDNA. The mean HPC of water coolers was determined at 38864 CFU/ml which exceeded the acceptable level for drinking water in 62% of analyzed samples. The HPC from the water coolers was also found to be significantly (P waters. The statistical analysis showed no significant difference between the values of pH, EC, turbidity and TOC in water coolers and tap waters. According to sequence analysis eleven species of bacteria were identified. A high HPC is indicative of microbial water quality deterioration in water coolers. The presence of some opportunistic pathogens in water coolers, furthermore, is a concern from a public health point of view. The results highlight the importance of a periodic disinfection procedure and monitoring system for water coolers in order to keep the level of microbial contamination under control.

  13. Fire control apparatus for a laser weapon

    Science.gov (United States)

    Worsham, R. H.

    1985-10-01

    This patent application discloses a laser weapon fire control computer apparatus for responding in real time to the escort/threat scenario that confronts the weapon. The fire control computer apparatus compares the threat data with stored predicted scenarios to develop a firing strategy menu which takes into account the fact that the laser energy is instantaneously propagated to the target but requires a substantial amount of time to inflict damage. The fire control computer apparatus utilizes the weapon's status, dwell time, slow time and fuel limits to yield a weapon pointing sequence and weapon on-off times.

  14. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    Improvements in an apparatus for isotope concentration by dual temperature exchange between feed and auxiliary fluids in a multistage system are described. The first fluid is a vaporizable liquid and the auxiliary fluid a gas, the apparatus having means for cascading the auxiliary fluid and the feed fluid in vapor and preferably also in liquid form. The apparatus also contains new combinations of means for improving the heating and/or cooling and/or humidifying and/or dehumidifying operations of the system. The reactants in the example given are hydrogen sulfide gas and liquid water

  15. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data...... indicative of operating parameters of the medical scanner (104); determine an output of a verification function based on the tracking data and the scanner data (106); and control the scanning monitoring apparatus according to the output of the verification function (108). A notification signal may...

  16. CHARACTERIZATION OF DIESEL SPRAY IMAGES USING A SHAPE PROCESSING METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Cecile Petit

    2011-05-01

    Full Text Available In Diesel engines, a key element in achieving a clean and efficient combustion process is a proper fuel-air mixing, which is a consequence of the fuel spray development and fuel-air interaction inside the engine combustion chamber. The spray structure and behavior are classically described by the length (penetration and width (angle of the spray plume but these parameters do not give any clue on the geometrical injection center and on the spray symmetry. The purpose of this paper is to find out original tools to characterize the Diesel spray: the virtual spray origin is the geometrical injection center, which may (or may not coincide with the injector axis. Another interesting point is the description of the Diesel spray in terms of symmetry: the spray plume internal and external symmetry characterize the spray and the injector performance. Our approach is first to find out the virtual spray origin: after the image segmentation, the spray is coded with the Freeman code and with an original shape coding from which the moments are derived. The symmetry axes are then computed and the spray plumes are discarded (or not for the virtual spray origin computation, which is derived from a Voronoi diagram. The last step is the internal and external spray plume symmetry characterization thanks to correlation and mathematical distances.

  17. Experimental characterization of gasoline sprays under highly evaporating conditions

    Science.gov (United States)

    Khan, Muhammad Mahabat; Sheikh, Nadeem Ahmed; Khalid, Azfar; Lughmani, Waqas Akbar

    2018-05-01

    An experimental investigation of multistream gasoline sprays under highly evaporating conditions is carried out in this paper. Temperature increase of fuel and low engine pressure could lead to flash boiling. The spray shape is normally modified significantly under flash boiling conditions. The spray plumes expansion along with reduction in the axial momentum causes the jets to merge and creates a low-pressure area below the injector's nozzle. These effects initiate the collapse of spray cone and lead to the formation of a single jet plume or a big cluster like structure. The collapsing sprays reduces exposed surface and therefore they last longer and subsequently penetrate more. Spray plume momentum increase, jet plume reduction and spray target widening could delay or prevent the closure condition and limit the penetration (delayed formation of the cluster promotes evaporation). These spray characteristics are investigated experimentally using shadowgraphy, for five and six hole injectors, under various boundary conditions. Six hole injectors produce more collapsing sprays in comparison to five hole injector due to enhanced jet to jet interactions. The spray collapse tendency reduces with increase in injection pressure due high axial momentum of spray plumes. The spray evaporation rates of five hole injector are observed to be higher than six hole injectors. Larger spray cone angles of the six hole injectors promote less penetrating and less collapsing sprays.

  18. Experimental characterization of gasoline sprays under highly evaporating conditions

    Science.gov (United States)

    Khan, Muhammad Mahabat; Sheikh, Nadeem Ahmed; Khalid, Azfar; Lughmani, Waqas Akbar

    2017-12-01

    An experimental investigation of multistream gasoline sprays under highly evaporating conditions is carried out in this paper. Temperature increase of fuel and low engine pressure could lead to flash boiling. The spray shape is normally modified significantly under flash boiling conditions. The spray plumes expansion along with reduction in the axial momentum causes the jets to merge and creates a low-pressure area below the injector's nozzle. These effects initiate the collapse of spray cone and lead to the formation of a single jet plume or a big cluster like structure. The collapsing sprays reduces exposed surface and therefore they last longer and subsequently penetrate more. Spray plume momentum increase, jet plume reduction and spray target widening could delay or prevent the closure condition and limit the penetration (delayed formation of the cluster promotes evaporation). These spray characteristics are investigated experimentally using shadowgraphy, for five and six hole injectors, under various boundary conditions. Six hole injectors produce more collapsing sprays in comparison to five hole injector due to enhanced jet to jet interactions. The spray collapse tendency reduces with increase in injection pressure due high axial momentum of spray plumes. The spray evaporation rates of five hole injector are observed to be higher than six hole injectors. Larger spray cone angles of the six hole injectors promote less penetrating and less collapsing sprays.

  19. COUPLED ATOMIZATION AND SPRAY MODELLING IN THE SPRAY FORMING PROCESS USING OPENFOAM

    DEFF Research Database (Denmark)

    Gjesing, Rasmus; Hattel, Jesper Henri; Fritsching, Udo

    2009-01-01

    The paper presents a numerical model capable of simulating the atomization, break-up and in-flight spray phenomena in the spray forming process. The model is developed and implemented in the freeware code openFOAM. The focus is on studying the coupling effect of the melt break-up phenomena...

  20. [Breast- and bottle-feeding in preterm infants: a comparison of behavioral cues].

    Science.gov (United States)

    Lin, Shih-Chun; Lin, Chen-Hsiu; Zhang, Jia-Wen; Chen, Siao-Min; Chen, Chih-Ling; Huang, Mei-Chih

    2013-12-01

    Developmental care has been broadly applied to identify the behavioral cues and care needs of preterm infants. Past studies indicate a significantly higher level of physical distress in bottle-fed preterm infants than in preterm infants who are breastfed. However, no evidence has yet been reported that supports the influence of feeding methods on behavioral cues. This study compares differences in the type and frequency of behavioral cues between breast- and bottle-fed preterm infants. A comparison study design and secondary data analysis method were used to assess data from two previous research projects. Infant feeding behavioral cues were observed and compared between two groups: 7 preterm infants who were breastfed and 7 preterm infants who were bottle-fed. After cases were matched by infant gestational age, behavioral responses were coded according to the preterm feeding cues coding system (PFCCS) from 7 paired maternal-infant feeding videos that featured preterm infants of 25 to 32 weeks gestational age at birth. The PFCCS classifies 24 feeding behavioral cues into hunger cues, self-regulatory cues, stress cues, and satiety cues. Infants in the breastfeeding group had a higher hunger cue frequency than their bottle-fed peers (p = .013), while bottle-fed infants had a higher stress cue frequency than their breastfed peers (p = .041). Other significant differences in behavioral cues between the two feeding methods included "fluid spillage" (bottle- >breast-, p = .008), "central cyanosis" (bottle- >breast-, p = .024) and "hand pushing" (breast- >bottle-, p = .034). Preterm infants in this study who breastfed showed significantly fewer stress cues than those who bottle fed. These findings support the importance of enhancing care provider sensitivity with regard to behavioral-cue observation. Findings further support breastfeeding rather than bottle-feeding for preterm infants.

  1. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria

    Directory of Open Access Journals (Sweden)

    Pedro-Egbe CN

    2011-05-01

    Full Text Available Chinyere Nnenne Pedro-Egbe, Chibuike Sydney Ejimadu, Henrietta NwachukwuDepartment of Ophthalmology, University of Port Harcourt Teaching Hospital, Port Harcourt, NigeriaBackground: Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon.Aim: To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future.Setting: Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria.Materials and methods: The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010 were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted.Results: A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6% males and 91 (21.4% females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA were light perception (2 cases, counting fingers (2 cases, and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7% cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema.Conclusion: Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative.Keywords: ocular injuries, exploding glass-bottled drink

  2. [A norovirus-borne outbreak caused by contaminated bottled spring water in a school, Zhejiang province].

    Science.gov (United States)

    Shen, Ji-chuan; Lin, Jun-fen; Gao, Jie; Yao, Wen-ting; Wen, Dong; Liu, Guang-tao; Han, Jian-kang; Ma, Hui-lai; Zhang, Li-jie; Zhu, Bao-ping

    2011-08-01

    To study a local hospital reported acute gastroenteritis in a boarding school on its source of infection, mode of transmission and risk factors of the infection. A suspected case was defined as who had developed diarrhea (≥ 3 times/day) or vomiting among teachers or students of the school, during April 19 - 30, 2010. A confirmed case was from a probable case plus tested positive for norovirus in stool specimens by using RT-PCR. Stool specimens of cases and environmental specimens were collected for laboratory diagnosis. In a case-control study, we compared exposures to sources of bottled water, consumption of bottled water, and hygienic habits of 220 probable or confirmed cases from April 21 - 23 in the peak of the outbreak, together with another 220 controls, with frequency-matched by school grade. 20.3% of the 1536 students but none of the teachers developed the disease. 98.6% of the cases (n = 217) and 85.5% (n = 188) of the controls had drunk bottled water in the classroom (OR(M-H) = 12.3, 95%CI: 3.7 - 40.9). 47.9% (n = 104) of the cases and 41.5% (n = 78) of the controls had drunk unboiled bottled water in classroom (OR(M-H) = 3.8, 95%CI: 1.5 - 9.6). 47.9% (n = 104) of the cases and 48.4% (n = 91) of the controls had drunk bottled mixed water (boiled and unboiled) in the classroom (OR(M-H) = 2.8, 95%CI: 1.1 - 7.0). Stool specimens from 3 cases and one bottle of uncovered bottled water in classroom showed positive of having norovirus genotype II. Coliforms was cultured much higher rates than standard deviations in the bottled water. The factory making the bottled water was not licensed or having strict disinfection facilities. Bottled spring water contaminated by norovirus was responsible for this outbreak.

  3. Trihalomethane concentrations in tap water as determinant of bottled water use in the city of Barcelona.

    Science.gov (United States)

    Font-Ribera, Laia; Cotta, Jordi Colomer; Gómez-Gutiérrez, Anna; Villanueva, Cristina M

    2017-08-01

    Bottled water consumption is increasing worldwide, despite its huge economic and environmental cost. We aim to describe personal and tap water quality determinants of bottled water use in the city of Barcelona. This cross-sectional study used data from the Health Survey of Barcelona in 2006 (N=5417 adults). The use of bottled water to drink and to cook was evaluated in relation to age, gender, educational level, district and levels of trihalomethanes (THMs), free chlorine, conductivity, chloride, sodium, pH, nitrate and aluminium in municipal tap water using Robust Poisson Regression. The prevalence of bottled water use to drink and cook was 53.9% and 6.7%, respectively. Chemical parameters in water had a large variability (interquartile range of THMs concentrations: 83.2-200.8μg/L) and were correlated between them, except aluminium. Drinking bottled water increased with educational level, while cooking with bottled water was higher among men than among women and decreased with age. After adjusting by these personal determinants, a dose-response relationship was found between concentrations of all chemicals except aluminium in tap water and bottled water use. The highest association was found for THMs, with a Prevalence Ratio of 2.00 (95%CI=1.86, 2.15) for drinking bottled water and 2.80 (95%CI=1.72, 4.58) for cooking with bottled water, among those with >150μg/L vs. tap water. More than half of Barcelona residents regularly drank bottled water, and the main determinant was the chemical composition of tap water, particularly THM level. Copyright © 2017. Published by Elsevier B.V.

  4. Association Between Bottle Size and Formula Intake in 2 Month Old Infants

    Science.gov (United States)

    Wood, Charles T.; Skinner, Asheley C.; Yin, H. Shonna; Rothman, Russell L.; Sanders, Lee M.; Delamater, Alan; Ravanbakht, Sophie N.; Perrin, Eliana M.

    2015-01-01

    Objective To determine range of bottle sizes used and examine the relationship between bottle size and total daily consumption of formula. Methods Cross-sectional analysis of baseline data collected as part of Greenlight, a cluster randomized trial to prevent childhood obesity at 4 pediatric resident clinics. The Greenlight study included healthy, term infants. For our analysis, parents of exclusively formula-fed infants reported volume per feed, number of feeds per day, and bottle size, which was dichotomized into “small” (ounces) or “large” (≥ 6 ounces). We identified determinants of bottle size, and then examined relationships between bottle size and volume fed with log-transformed OLS regression, adjusting for infant age, sex, birth weight, current weight, race/ethnicity, and enrollment in WIC. Results Of 865 participants in the Greenlight study, forty-four percent (n=378; 21.8% white, 40.6% black, 35.3% Hispanic, 2.4% other) of infants were exclusively formula-fed at 2 months. Median volume per day was 30 ounces (IQR 12) and 46.0% of infants used large bottles. Adjusted for covariates, parents using larger bottles reported feeding 4 ounces more formula per day (34.2 ounces, 95% CI: 33.5-34.9 vs. 29.7 ounces, 95% CI: 29.2-30.3, p=0.03). Conclusions Among exclusively formula-fed infants, use of a larger bottle is associated with parental report of more formula intake when compared with infants fed with smaller bottles. If infants fed with larger bottles receive more formula, these infants may be overfed, and, consequently, at risk for obesity. PMID:26525989

  5. Bi-planal angiographic apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Angiography apparatus has an L-arm rotatable about a vertical axis and a U-arm mounted on the upstanding section of the L-arm for rotation about a horizontal axis. An x-ray source is at one end of the U-arm and image receptors including an image intensifier and a first film changer are at the other end to enable making posterior-anterior and anterior-posterior x-ray views at various angles relative to a patient who is located on the isocenter which is the intersection of the horizontal, vertical and x-ray beam axis. A second film changer for making lateral generally isocentric views is mounted within the U-arm on a stand that is movable along the horizontal U-arm axis to allow obtaining various distances between the image plane of the film and another x-ray source. The lateral changer is on a mechanism for shifting it vertically and longitudinally a limited amount and for rotating it with a motor so this changer will stay level until the U-arm has been tilted through a pre-determined angle. After this angle is reached motorized rotation is discontinued and the lateral changer is allowed to rotate with the U-arm. (Auth.)

  6. Isotope separation apparatus and method

    International Nuclear Information System (INIS)

    Cotter, T.P.

    1982-01-01

    The invention relates to a method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferable substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. The laser beam comprises pi-pulses of a selected wavelength which excite unexcited molecules, or cause stimulated emission of excited molecules of one of the isotopes. Excitation caused by first direction pi-pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning pi-pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement is accomplished by a large number of pi-pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam

  7. Hanging drop crystal growth apparatus

    Science.gov (United States)

    Naumann, Robert J. (Inventor); Witherow, William K. (Inventor); Carter, Daniel C. (Inventor); Bugg, Charles E. (Inventor); Suddath, Fred L. (Inventor)

    1990-01-01

    This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

  8. Powder collection apparatus/method

    Science.gov (United States)

    Anderson, I.E.; Terpstra, R.L.; Moore, J.A.

    1994-01-11

    Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally equal to the angle of the housing interior wall measured from the same horizontal plane so as to direct the gas stream into the expansion chamber generally tangent to the housing interior wall to establish a downward swirling gas stream flow in the expansion chamber. A powder collection container is communicated to the outlet of the expansion chamber to collect the powder for further processing. 4 figures.

  9. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  10. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1975-01-01

    Apparatus and methods for verifying the validity of data derived at least in part by neutron logging of earth formations, and, where indicated, for affording neutron diffusion-corrected values of such data, are disclosed. (WHK)

  11. Method and apparatus for measuring electromagnetic radiation

    Science.gov (United States)

    Been, J. F. (Inventor)

    1973-01-01

    An apparatus and method are described in which the capacitance of a semiconductor junction subjected to an electromagnetic radiation field is utilized to indicate the intensity or strength of the radiation.

  12. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be equipped with a substantial, durable container bearing markings which show the applicant's name, the type...

  13. Universal penetration test apparatus with fluid penetration sensor

    Science.gov (United States)

    Johnson, P.W.; Stampfer, J.F.; Bradley, O.D.

    1999-02-02

    A universal penetration test apparatus is described for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material. 23 figs.

  14. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  15. Proton imaging apparatus for proton therapy application

    International Nuclear Information System (INIS)

    Sipala, V.; Lo Presti, D.; Brianzi, M.; Civinini, C.; Bruzzi, M.; Scaringella, M.; Talamonti, C.; Bucciolini, M.; Cirrone, G.A.P.; Cuttone, G.; Randazzo, N.; Stancampiano, C.; Tesi, M.

    2011-01-01

    Radiotherapy with protons, due to the physical properties of these particles, offers several advantages for cancer therapy as compared to the traditional radiotherapy and photons. In the clinical use of proton beams, a p CT (Proton Computer Tomography) apparatus can contribute to improve the accuracy of the patient positioning and dose distribution calculation. In this paper a p CT apparatus built by the Prima (Proton Imaging) Italian Collaboration will be presented and the preliminary results will be discussed.

  16. Report upon inquiry into radiation apparatus

    International Nuclear Information System (INIS)

    1984-10-01

    In this report the committee has provided its assessment of the need and justification for the law to provide for the control of the provision of radiation apparatus, the planning needs for the provision of diagnostic and therapeutic facilities, the location of such facilities, the appropriateness or otherwise of existing legislation, the necessity for any further legislative needs and the criteria governing the provision of such radiation apparatus

  17. Containment atmosphere response to external sprays

    Energy Technology Data Exchange (ETDEWEB)

    Green, J.; Almenas, K. [Univ. of Maryland, College Park, MD (United States)

    1995-09-01

    The application of external sprays to a containment steel shell can be an effective energy removal method and has been proposed in the passive AP-600 design. Reduction of the steel shell temperature in contact with the containment atmosphere enhances both heat and mass transfer driving forces. Large scale experimental data in this area is scarce, therefore the measurements obtained from the E series tests conducted at the German HDR facility deserve special attention. These long term tests simulated various severe accident conditions, including external spraying of the hemispherical steel shell. This investigation focuses upon the integral response of the HDR containment atmosphere during spray periods and upon methods by which lumped parameter system codes, like CONTAIN, model the underlying condensation phenomena. Increases in spray water flowrates above a minimum value were ineffective at improving containment pressure reduction since the limiting resistance for energy transfer lies in the noncondensable-vapor boundary layer at the inner condensing surface. The spray created an unstable condition by cooling the upper layers of a heated atmosphere and thus inducing global natural circulation flows in the facility and subsequently, abrupt changes in lighter-than-air noncondensable (J{sub 2}/He) concentrations. Modeling results using the CONTAIN code are outlined and code limitations are delineated.

  18. Cask handling method and apparatus

    International Nuclear Information System (INIS)

    Yoli, A.H.; Husain, I.

    1977-01-01

    The method of transferring radioactive material into and out of the cask comprises positioning a tank with an open end in a well. Then a cask having a passage for moving radioactive material into and out of the cask is placed in the tank through the opening in the tank. The tank opening is then sealed to the cask relative to the well without sealing the passage relative to the well to prevent water filled into the well from leaking into the tank. Then the well is filled with water above the seal, and radioactive material is then moved through the water in the well through the passage into the cask. The tank may be filled with demineralized water from a separate source to pressurize the space in the tank on the other side of the seal from the well to prevent water in the well from entering the tank. The water level in the well and in the tank is then lowered, the tank opening to the cask seal is removed, and a cover is attached to the cask passage to maintain the radioactive material and contaminated water in the cask. The apparatus which accomplishes the above method comprises a tank in a well for receiving a cask therein. A seal between the tank and the cask prevents water in the well from flowing into the tank about the cask and permits water in the well to flow through the cask opening into the cask. A first water supply means raises and lowers the water level in the well, and a second water supply means supplies clean demineralized water to the tank under pressure to prevent water in the well from leaking into the tank. The seal is annularly shaped and is attached to the top of the tank. The central portion of the annular seal is aligned with the cask opening and it has means to seal the annular seal to the cask

  19. Quantum behaviour of measuring apparatus

    International Nuclear Information System (INIS)

    Amri, T.

    2011-05-01

    This thesis explores the quantum behavior of measurement apparatus with illustrations in quantum optics. This is the first study of quantum properties of measurements performed by any kind of devices. We show that the quantum properties of a measurement, such as its projective or non-classical character, are revealed only by the quantum states of an unusual approach of quantum physics: the retrodictive approach. This approach involves retro-predictions about state preparations leading to a given measurement result, contrary to the predictive approach with which we usually make predictions about the results of an experiment. By clarifying the mathematical foundations of the retrodictive approach, we propose a general procedure for reconstructing the quantum states of this approach: the retrodicted states. We have realized these reconstructions for single-photon detectors, widely used in quantum cryptography for instance. This is the first tomography of quantum states totally based on the retrodictive approach and preparation choices, contrary to usual reconstructions based on measurement results. These tomographies enabled us to study experimentally the noise influence on the quantum properties of measurements performed by these detectors, in particular their transition from a strongly quantum behavior into a more classical behavior. Finally, we propose a detector of Schroedinger's Cat states of light, which are superpositions of incompatible quasi-classical states of light. In a modern version of a thought experiment proposed by Eugene Wigner in 1961, such a device could allow the Wigner's Friend to detect a Schroedinger's Cat, contrary to human eyes for which we specify some quantum properties. We generalize the use of such a non-classical detector to an estimation protocol, totally based on the retrodictive approach and preparation choices. Such a procedure could enable optimal estimations, by reaching the quantum Cramer-Rao bound, which is a very topical issue

  20. 226Ra and natural uranium in egyptian bottled mineral waters

    International Nuclear Information System (INIS)

    Higgy, R.H.

    2000-01-01

    Concentration levels of 226 Ra and natural uranium have been analysed bottled mineral water commercially available in egypt. 226 Ra was determined by applying a chemical procedure in which Ra was coprecipitated with Ba as sulphate. The precipitate was then dissolved with EDTA and then measured by liquid scintillation system, after mixing with a scintillation cocktail. Natural uranium was determined by applying a chemical procedure for uranium extraction using MIBK and then measured using laser fluorimeter system. The concentration values obtained were compared with concentrations reported by other countries and with reference values accepted for drinking water. Based on the consumption rate and the measured concentrations, the collective committed effective doses were calculated. In addition, Ca, Mg and Na were measured using Icp system and compared with some worldwide values

  1. Recycling of PET bottles as fine aggregate in concrete.

    Science.gov (United States)

    Frigione, Mariaenrica

    2010-06-01

    An attempt to substitute in concrete the 5% by weight of fine aggregate (natural sand) with an equal weight of PET aggregates manufactured from the waste un-washed PET bottles (WPET), is presented. The WPET particles possessed a granulometry similar to that of the substituted sand. Specimens with different cement content and water/cement ratio were manufactured. Rheological characterization on fresh concrete and mechanical tests at the ages of 28 and 365days were performed on the WPET/concretes as well as on reference concretes containing only natural fine aggregate in order to investigate the influence of the substitution of WPET to the fine aggregate in concrete. It was found that the WPET concretes display similar workability characteristics, compressive strength and splitting tensile strength slightly lower that the reference concrete and a moderately higher ductility. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. Preventing baby bottle tooth decay: eight-year results.

    Science.gov (United States)

    Bruerd, B; Jones, C

    1996-01-01

    Baby bottle tooth decay (BBTD) is a preventable dental disease that affects more than 50% of American Indian/Alaska Native (AI/AN) children. A community-oriented program to prevent BBTD was implemented in 12 AI/AN communities in 1986. In 1989, the overall prevalence of BBTD for the 12 sites combined decreased from 57% to 43% which represented a 25% reduction (P<.001). Funding for the formal program was discontinued in 1990. In 1994, the Indian Health Service Dental and Head Start funded an assessment of the current prevalence of BBTD and the level of program implementation at the 12 original sites. This paper describes the findings. At the five sites where both one-to- one counseling and community-based educational activities had continued, BBTD prevalence was reduced by 38%(P<.001) over the eight-year period. PMID:8610193

  3. Biochemical monitoring of sweet fruit flavoured glass bottled soft drinks

    International Nuclear Information System (INIS)

    Watto, M.H.S.; Kazi, T.G.; Bhanger, M.I.; Jakhrani, M.A.; Iqbal, J.; Porgar, A.S.

    2000-01-01

    Fruit flavored glass bottled soft drinks are widely used in developing countries including Pakistan. People suffer greatly both in terms of health and economy if soft drinks are contaminated with microbes and toxic metals. Samples of sixteen different brands of soft drinks were analyzed for microbial and trace elemental study. Microbial study included identification of different coliforms like E. coli, Bacillus cereus, Salmonella, Shigella, Enterobacter, Klebsiela, and total Coliforms. Only seven samples were found to be free from investigated microbes. Contamination in other samples was probably due to improper handling and storage and could be dangerous to human health. Fifteen trace and toxic elements were determined by atomic absorption spectrophotometry following improved ash digestion method. The level of Al, Fe, Na, K, Ni, Pb and Cd was found to be higher in investigated samples than the international safety limits of WHO. Other elements investigated in all the samples were below the WHO maximum allowable concentration for drinking water. (author)

  4. Recycling of PET bottles as fine aggregate in concrete

    International Nuclear Information System (INIS)

    Frigione, Mariaenrica

    2010-01-01

    An attempt to substitute in concrete the 5% by weight of fine aggregate (natural sand) with an equal weight of PET aggregates manufactured from the waste un-washed PET bottles (WPET), is presented. The WPET particles possessed a granulometry similar to that of the substituted sand. Specimens with different cement content and water/cement ratio were manufactured. Rheological characterization on fresh concrete and mechanical tests at the ages of 28 and 365 days were performed on the WPET/concretes as well as on reference concretes containing only natural fine aggregate in order to investigate the influence of the substitution of WPET to the fine aggregate in concrete. It was found that the WPET concretes display similar workability characteristics, compressive strength and splitting tensile strength slightly lower that the reference concrete and a moderately higher ductility.

  5. Growth of Scytalidium sp. in a counterfeit bevacizumab bottle

    Directory of Open Access Journals (Sweden)

    Gerardo Garcia-Aguirre

    2013-01-01

    Full Text Available After drawing a dose from an closed bevacizumab (Avastin bottle, a fungus-like foreign body was observed inside. Samples from the vial were cultured in Sabouraud Emmons media. Growth of multiple light brown colonies with dark pigment was observed after 10 days. The species was identified as Scytalidium sp.Vial, analysis reported that the seal was lacking proper identification measures and that the label, batch number and expiry date did not correspond to a genuine product. Chemical analysis showed no protein, but 3% of polyethylene glycol, citrate and ethanol. Counterfeit bevacizumab is a real situation that poses a significant risk for ophthalmology and oncology patients. The medical community should be aware of this situation in order to enforce adequate preventive measures.

  6. A microbiological study of bottled mineral water marketed in Ludhiana.

    Science.gov (United States)

    Lal, M; Kaur, H

    2006-01-01

    The microbiological quality of bottled mineral water marketed in Ludhiana was examined, Twenty three brands were analyzed for presumptive coliform count by multiple tube tests, and E. coli count was confirmed by Eijkman test. Bacterial and fungal loads were tested by membrane filtration test. Out of 23 only one sample (4.4%) showed the presumptive coliform count to be 460 most probable number (MPN)l 1 00ml,and 1 was found to be positive when tested by Eijkman test for Ecoli. In the membrane filtration test three samples (13%) showed more than two types of bacteria. Different types of bacteria isolated included Bacillus sp (19/23). Pseudomonas spp (13123), Ecoli, Klebsiella sp and S.albus one each Fungi was isolated from five of twenty three. (22%) samples. Only one brand of mineral water was unfit for human consumption. The rest of the samples were contaminated with non pathogenic flora.

  7. Blood culture bottles are superior to conventional media for vitreous culture.

    Science.gov (United States)

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  8. What's Wrong with the Tap? Examining Perceptions of Tap Water and Bottled Water at Purdue University

    Science.gov (United States)

    Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon

    2011-09-01

    The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates ( n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors—especially whether individuals trust tap water to be clean—but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.

  9. The photocatalytic enhancement of acrylic and PET solar water disinfection (SODIS) bottles.

    Science.gov (United States)

    Carey, J M; Perez, T M; Arsiaga, E G; Loetscher, L H; Boyd, J E

    2011-01-01

    The solar water disinfection method (SODIS) was modified by the addition of a photocatalytic layer of titania on the interior surface of polyethylene terephthalate (PET) and acrylic bottles. Titania was solvent deposited on the interior of commercially available PET bottles, as well as bottles that were constructed from acrylic. Uncoated and titania-coated acrylic bottles removed 3,000,000-5,000,000 colony forming units per milliliter of K12 E. coli from 670 mL of contaminated water in 40 min of solar irradiance. After five hours of sunlight exposure, the concentration of 10 ppm methyl orange (a representative organic water contaminant), was reduced by 61% using the titania-coated acrylic bottles. The concentration of 87 ppb microcystin-LR (a representative algal toxin) was reduced by 70% after 7 hours of sunlight exposure in the titania-coated acrylic bottles. Acrylic is an effective alternative to PET for use in the SODIS method due to its greater UV transparency. The addition of titania to PET and acrylic bottles confers the ability to remove chemical contaminants in addition to inactivating microbiological contaminants.

  10. Accessories modifying based on plastic waste of shampoo bottle as home economic product

    Science.gov (United States)

    Setyowati, Erna; Sukesi, Siti

    2018-03-01

    Plastic is a waste that can not decompose by the soil and if its left without a good handling can pollute the environment. Plastic waste needs processing by the recycle bottles principle. Shampoo bottle is one of plastic waste with high density polyethylene type (HDPE). One of the innovation to recycling shampoo bottles waste into the new products whichbeneficially and aestheticallyform by engineered the buns accesories. Accessories are one of the tools used by most women, in the form of trinkets or ornaments which ajusted to the trend to beautify the look. Accessories from shampoo bottle waste can be obtained from household waste, beauty salon and the beauty program study by inculcating human beings' behavior by transforming waste into blessing while also increasing family income. Technique of making its by compiling through improvement of panelist team. The goal of this research is to engineering theaccessories based on shampoo bottle waste as home economics. The method are using experiment, observation and documentation, analysis using descriptive. The results obtained from the overall sensory test averaged at 93%, while the favored test averaged at 85.5%. The product can be ordered according to the desired design, but it takes a long time. Therefore accessories engineering from shampoo bottles waste-based can be used as home economics. The production of shampoo bottles waste-based accessories should improved its quality and quantity, to be marketed through the community, by the cooperation with accessories and bun craftsmen.

  11. Design, Development and Testing of Inconel Alloy IN718 Spherical Gas Bottle for Oxygen Storage

    Science.gov (United States)

    Chenna Krishna, S.; Agilan, M.; Sudarshan Rao, G.; Singh, Satish Kumar; Narayana Murty, S. V. S.; Venkata Narayana, Ganji; Beena, A. P.; Rajesh, L.; Jha, Abhay K.; Pant, Bhanu

    2017-11-01

    This paper describes the details of design, manufacture and testing of 200 mm diameter spherical gas bottle of Inconel 718 (IN718) with nominal wall thickness of 2.3 mm. Gas bottle was designed for the specified internal pressure loading with a thickness of 2.9 mm at the circumferential weld which was brought down to 2.3 mm at the membrane locations. Hemispherical forgings produced through closed-die hammer forging were machined and electron beam welded to produce a spherical gas bottle. Duly welded gas bottle was subjected to standard aging treatment to achieve the required tensile strength. Aged gas bottle was inspected for dimensions and other stringent quality requirements using various nondestructive testing techniques. After inspection, gas bottle was subjected to pressure test for maximum expected operating pressure and proof pressure of 25 and 37.5 MPa, respectively. Strain gauges were bonded at different locations on the gas bottle to monitor the strains during the pressure test and correlated with the predicted values. The predicted strain matched well with the experimental strain confirming the design and structural integrity.

  12. Estrogenic activity, selected plasticizers and potential health risks associated with bottled water in South Africa.

    Science.gov (United States)

    Aneck-Hahn, Natalie H; Van Zijl, Magdalena C; Swart, Pieter; Truebody, Barry; Genthe, Bettina; Charmier, Jessica; Jager, Christiaan De

    2018-04-01

    Potential endocrine disrupting chemicals (EDCs) are present in bottled water from various countries. In South Africa (SA), increased bottled water consumption and concomitant increases in plastic packaging create important consequences for public health. This study aimed to screen SA bottled water for estrogenic activity, selected target chemicals and assessing potential health risks. Ten bottled water brands were exposed to 20 °C and 40 °C over 10 days. Estrogenic activity was assessed using the recombinant yeast estrogen screen (YES) and the T47D-KBluc reporter gene assay. Solid phase extracts of samples were analyzed for bis(2-ethylhexyl) adipate (DEHA), selected phthalates, bisphenol-A (BPA), 4-nonylphenol (4-NP), 17β-estradiol (E 2 ), estrone (E 1 ), and ethynylestradiol (EE 2 ) using gas chromatography-mass spectrophotometry. Using a scenario-based health risk assessment, human health risks associated with bottled water consumption were evaluated. Estrogenic activity was detected at 20 °C (n = 2) and at 40 °C (n = 8). Estradiol equivalent (EEq) values ranged from 0.001 to 0.003 ng/L. BPA concentrations ranged from 0.9 ng/L to 10.06 ng/L. Although EEqs and BPA concentrations were higher in bottled water stored at 40 °C compared to 20 °C, samples posed an acceptable risk for a lifetime of exposure. Irrespective of temperature, bottled water from SA contained chemicals with acceptable health risks.

  13. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Directory of Open Access Journals (Sweden)

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  14. Investigation of spray characteristics in a spray-guided DISI engine using PLIF and LDV

    International Nuclear Information System (INIS)

    Yan, Y; Gashi, S; Nouri, J M; Lockett, R D; Arcoumanis, C

    2007-01-01

    The spray characteristics of a prototype piezo pintle-type injector are investigated in a single-cylinder optical direct injection spark ignition (DISI) engine based on the spray-guided concept where mixture preparation is dominated by the spray dynamics. The high-pressure piezo electric injector has an annular nozzle providing a hollow cone spray. Planar Laser-induced Fluorescence (PLIF) and 2-dimensional Mie scattering were used to study the spray structure and characteristics under different in-cylinder back pressures and to obtain cycle resolved measurements of the planar fuel distribution inside the cylinder. The obtained results give information about the extent of charge stratification, spray stability and fuel/air mixture formation process under operating conditions. PLIF results revealed that there is a rich mixture at the spark plug position for all these conditions, ensuring stable combustion over the entire engine operating range. In addition, LDV measurements were carried out in order to provide information on the in-cylinder flow field near the spark plug, and to assess its influence on the mixture formation process. LDV results showed that the influence of the flow field strength during the late compression injection on the liquid fuel spray structure is low. The tumble generated in the cylinder is transformed into turbulence at the end of the compression stroke, which aids fuel evaporation and vapour dispersion just before ignition

  15. Development of a permeation panel to test dermal protective clothing against sprayed coatings.

    Science.gov (United States)

    Ceballos, Diana M; Yost, Michael G; Whittaker, Stephen G; Reeb-Whitaker, Carolyn; Camp, Janice; Dills, Russell

    2011-03-01

    Design, construct, and characterize an apparatus to evaluate dermal protective clothing for resistance to polymerizing materials. Specifically, we evaluated the permeation of the most common glove material used in automotive collision repair (0.10-0.13 mm or 4-5 mil latex) with representative isocyanate-containing clear coats. Our ultimate goal is to make informed recommendations on dermal protective materials to prevent isocyanate exposures and reduce the likelihood of occupational illness in automotive collision repair and other industries. A novel permeation panel was developed to assess dermal protective clothing. With this apparatus, up to eight test materials may be evaluated under typical-spray application conditions. Solid collection media comprised of 1-(2-pyridyl)-piperazine (2-PP)-coated fiberglass filters or colorimetric SWYPE™ pads were placed behind test materials to capture permeants. The 2-PP-coated filters were subsequently analyzed using a modified OSHA42/PV2034 method. Color change in the SWYPEs provided an immediate field estimate of breakthrough time. In addition, Teflon filters were mounted proximal to the permeation cells to measure the mass of clear coat applied to the panel and to evaluate loading homogeneity. This study evaluated the permeation of isocyanates through 0.10-0.13 mm latex glove material at a fixed time (30 min post-spraying) and over a time course (6-91 min post-spraying). Monomers 1,6-hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI) permeated through (0.10-0.13 mm) latex glove material under typical glove use conditions (30 min). The latex glove material exhibited immediate breakthrough, with a permeation rate of 2.9 ng min(-1) cm(-2). The oligomeric forms of HDI and IPDI did not permeate the latex glove material. The spray application at 71 ± 5 °F was fairly homogeneous (33.7 ± 8 mg weight of dry clear coat per 5 cm(2)). The permeation panel is a viable method to assess dermal protective clothing

  16. Density of Spray-Formed Materials

    Energy Technology Data Exchange (ETDEWEB)

    Kevin M. McHugh; Volker Uhlenwinkel; Nils Ellendr

    2008-06-01

    Spray Forming is an advanced materials processing technology that transforms molten metal into a near-net-shape solid by depositing atomized droplets onto a substrate. Depending on the application, the spray-formed material may be used in the as-deposited condition or it may undergo post-deposition processing. Regardless, the density of the as-deposited material is an important issue. Porosity is detrimental because it can significantly reduce strength, toughness, hardness and other properties. While it is not feasible to achieve fully-dense material in the as-deposited state, density greater than 99% of theoretical density is possible if the atomization and impact conditions are optimized. Thermal conditions at the deposit surface and droplet impact angle are key processing parameters that influence the density of the material. This paper examines the factors that contribute to porosity formation during spray forming and illustrates that very high as-deposited density is achieved by optimizing processing parameters.

  17. Examining properties of arc sprayed nanostructured coatings

    Directory of Open Access Journals (Sweden)

    A. Czupryński

    2016-04-01

    Full Text Available The article presents the results of examining properties of arc sprayed coating obtained with nano-alloy on the iron matrix with a high amount of fine carbide precipitates sprayed on non-alloyed steel plates intended for high temperature operation. Powder metal cored wire EnDOtec DO*390N 1,6 mm diameter, was used to produce, dense, very high abrasion and erosion resistant coatings approx. 1,0 mm thick. Nano-material coatings characterization was done to determine abrasion resistance, erosion resistance, adhesion strength, hardness as well as metallographic examinations. Results have proved high properties of arc sprayed nano-material coatings and have shown promising industrial applications.

  18. Analysis of polydisperse fuel spray flame

    Science.gov (United States)

    Nave, Ophir; Lehavi, Yaron; Ajadi, Suraju; Gol'dshtein, Vladimir

    2017-02-01

    In this paper we analyzed the model of polydisperse fuel spray flame by using the sectional approach to describe the droplet-droplet interaction within the spray. The radii of the droplets are described by a probability density function. Our numerical simulations include a comparative analysis between three empirical droplet size distributions: the Rosin-Rammler distribution, the log-normal distribution and the Nakiyama-Tanasawa distribution. The log-normal distribution was found to produce a reasonable approximation to both the number and volume size distribution function. In addition our comparative analysis includes the application of the homotopy analysis method which yields convergent solutions for all values of the relevant parameters. We compared the above results to experimental fuel spray data such as {it{Tetralin}}, n-{it{Decane}}, and n-{it{Heptane}}.

  19. Silver nasal sprays: misleading Internet marketing.

    Science.gov (United States)

    Gaslin, Michael T; Rubin, Cory; Pribitkin, Edmund A

    2008-04-01

    Long-term use of silver-containing products is associated with a permanent bluish-gray discoloration of the skin known as argyria, but they remain widely available despite several measures by the FDA to regulate them. Several recent case reports have described the occurrence of argyria as a result of using these "natural" products. We used the five most common Internet search engines to find Web sites providing information on silver-containing nasal sprays. Of 49 Web sites analyzed, only 2 (4%) mentioned argyria as a possible complication, although 30 (61%) did caution against long-term use. Eight sites (16%) made specific claims about the health benefits of the product. All 49 sites (100%) provided direct or indirect links to buy silver-containing nasal sprays. We conclude that information about silver-containing nasal sprays on the Internet is misleading and inaccurate. Therefore, otolaryngologists should be aware of the misinformation their patients may be receiving about these products.

  20. Water spray assisted ultrashort laser pulse ablation

    International Nuclear Information System (INIS)

    Silvennoinen, M.; Kaakkunen, J.J.J.; Paivasaari, K.; Vahimaa, P.

    2013-01-01

    Highlights: ► We show the novel method to use multibeam processing with ultrashort pulses efficiently. ► Sprayed thin water layer on ablation zone enhances ablation rate and quality. ► In some cases this method also enables ablation of the deeper and straighter holes compared to ones made without the water layer. ► Method also makes possible to directly write features without the self-organizing structures. - Abstract: We have studied femtosecond ablation under sprayed thin water film and its influence and benefits compared with ablation in the air atmosphere. These have been studied in case of the hole and the groove ablation using IR femtosecond laser. Water enhances the ablation rate and in some situations it makes possible to ablate the holes with a higher aspect ratio. While ablating the grooves, the water spray allows using the high fluences without the generation of the self-organized structures.

  1. Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles.

    Science.gov (United States)

    Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J; Meierhofer, Regula; Luzi, Samuel; Kohn, Tamar

    2015-10-23

    Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm(2)) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm(2). Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  2. Bottled water, spas, and early years of water chemistry

    Science.gov (United States)

    Back, William; Landa, Edward R.; Meeks, Lisa

    1995-01-01

    Although hot springs have been used and enjoyed for thousands of years, it was not until the late 1700s that they changed the course of world civilization by being the motivation for development of the science of chemistry. The pioneers of chemistry such as Priestley, Cavendish, Lavoisier, and Henry were working to identify and generate gases, in part, to determine their role in carbonated beverages. In the 18th century, spas in America were developed to follow the traditional activities of popular European spas. However, they were to become a dominant political and economic force in American history on three major points: (1) By far the most important was to provide a place for the leaders of individual colonies to meet and discuss the need for separation from England and the necessity for the Revolutionary War; (2) the westward expansion of the United States was facilitated by the presence of hot springs in many locations that provided the economic justification for railroads and settlement; and (3) the desire for the preservation of hot springs led to the establishment of the National Park Service. Although mineral springs have maintained their therapeutic credibility in many parts of the world, they have not done so in the United States. We suggest that the American decline was prompted by: (1) the establishment of The Johns Hopkins School of Medicine in 1893; (2) enactment of the Pure Food and Drug Act of 1907; and (3) the remarkable achievement of providing safe water supplies for American cities by the end of the 1920s. The current expanding market for bottled water is based in part on bottled water being an alternative beverage Ito alcohol and sweetened drinks and the inconsistent palatability and perceived health hazards of some tap waters.

  3. Evaluation of bottled nutritive drinks using a taste sensor.

    Science.gov (United States)

    Kataoka, Masumi; Miyanaga, Yohko; Tsuji, Eriko; Uchida, Takahiro

    2004-07-26

    The purpose of this study was to evaluate the taste of 20 bottled nutritive drinks, all commercially available on the Japanese market, both in human gustatory sensation tests and using a multi-channel taste sensor. In the gustatory sensation tests, seven trained healthy volunteers were asked to score the drinks in terms of the intensities of four basic tastes (sweetness, saltiness, sourness, and bitterness), for overall palatability (ease of drinking), and for nine components of palatability (astringency, pungency, fruitiness, tasting of a medicinal plant, refreshing, irritating to the throat, seeming beneficial, good aftertaste, and the desire to drink again). The data were analysed to determine the critical factors for overall palatability. There was a positive linear correlation between overall palatability and 'sourness', 'fruitiness', 'refreshing', and 'good aftertaste' scores (r = 0.79, 0.85, 0.74, and 0.70, respectively). There was a negative correlation between overall palatability and 'bitterness intensity', 'tasting of a medicinal plant', 'seeming beneficial', and 'pungency' scores (r = -0.76, -0.64, -0.62, and -0.50, respectively). When evaluated using a multi-channel taste sensor, there was a positive linear correlation between the intensities of sourness and bitterness determined by the human volunteers and those predicted by the taste sensor (r = 0.85 and 0.71, respectively). The pungency intensity, as evidenced in gustatory sensation tests, could be also predicted by sensor output (r = 0.84). The taste sensor seems therefore to be a potentially useful tool in evaluating the palatability of bottled nutritive drinks.

  4. Measurements of radon and radium activity in bottled mineral water

    International Nuclear Information System (INIS)

    Kappke, Jaqueline; Paschuk, Sergei A.; Correa, Janine N.; Reque, Marilson; Tabuchi, Camila Garcia; Del Claro, Flavia; Perna, Allan Felipe; Deniak, Valeriy

    2013-01-01

    Current work presents the results of further development of optimized experimental protocol for RAD7 instant radon detector (Durridge Company Inc.) usage in low level radon in water measurements and the results concerning Ra-226 activity evaluation in bottled mineral water samples purchased at Brazilian market. With the purpose to achieve the statistically consistent results for the activity levels of 0.1Bq/L for radon (radium) activity in water, present study used modified experimental protocol which consists of: 1) water samples were stored in hermetically sealed glass vials of 250mL during 30 days to guarantee that Rn-222 will reach the secular equilibrium; 2) the measurements were performed using WAT250 protocol of RAD7 detector; 3) with an aim to decrease the background, the cleaning (activated carbon filter) and drying (DRIERITE desiccant) vessels, which have a function to retain the radioactive decay product of Rn-222 and humidity, were connected to a closed air loop of RAD7 permanently by means of valves and taps, which gave a possibility to repeat all sequence of measurements (including background evaluation) three or four times without to open the air loop and disconnect the sample vial with water. Each water sample was submitted to such measurements two or three times. Obtained results presented the level of Ra-226 activity in studied samples of bottled mineral water that varied from 0.007 ± 0.061 Bq/L to 0.145 ± 0.049 Bq/L, which is below the limit of 0,5 Bq/L established by the World Health Organization (WHO) in 2011 for drinking water. (author)

  5. Measurements of radon and radium activity in bottled mineral water

    Energy Technology Data Exchange (ETDEWEB)

    Kappke, Jaqueline; Paschuk, Sergei A.; Correa, Janine N.; Reque, Marilson; Tabuchi, Camila Garcia; Del Claro, Flavia; Perna, Allan Felipe, E-mail: jaquelinekappke@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Deniak, Valeriy [Instituto de Pesquisa Pele Pequeno Principe, Curitiba, PR (Brazil)

    2013-07-01

    Current work presents the results of further development of optimized experimental protocol for RAD7 instant radon detector (Durridge Company Inc.) usage in low level radon in water measurements and the results concerning Ra-226 activity evaluation in bottled mineral water samples purchased at Brazilian market. With the purpose to achieve the statistically consistent results for the activity levels of 0.1Bq/L for radon (radium) activity in water, present study used modified experimental protocol which consists of: 1) water samples were stored in hermetically sealed glass vials of 250mL during 30 days to guarantee that Rn-222 will reach the secular equilibrium; 2) the measurements were performed using WAT250 protocol of RAD7 detector; 3) with an aim to decrease the background, the cleaning (activated carbon filter) and drying (DRIERITE desiccant) vessels, which have a function to retain the radioactive decay product of Rn-222 and humidity, were connected to a closed air loop of RAD7 permanently by means of valves and taps, which gave a possibility to repeat all sequence of measurements (including background evaluation) three or four times without to open the air loop and disconnect the sample vial with water. Each water sample was submitted to such measurements two or three times. Obtained results presented the level of Ra-226 activity in studied samples of bottled mineral water that varied from 0.007 ± 0.061 Bq/L to 0.145 ± 0.049 Bq/L, which is below the limit of 0,5 Bq/L established by the World Health Organization (WHO) in 2011 for drinking water. (author)

  6. Bottle feeding, increased overjet and Class 2 primary canine relationship: is there any association?

    Directory of Open Access Journals (Sweden)

    Nadia Salem Abdel Jabbar

    2011-08-01

    Full Text Available The aim of this study was to investigate the association between bottle feeding and prevalence rates of increased overjet and Class 2 primary canine relationship. The sample consisted of 911 children (461 boys, 450 girls aged 3 (13.9%, 4 (40.8%, 5 (34% and 6 (11.3% years, with complete primary dentition. Information about nutritive and nonnutritive (pacifier and/or digit sucking habits was collected through questionnaires. Three calibrated dentists (κ: 0.9-1.0 and Rs > 0.90 performed the clinical assessments. The children were divided into four groups: G1 - not bottle-fed; G2 - exclusively bottle-fed; G3 - breast- and bottle-fed, bottle feeding ceased before 3 years of age; and G4 - breast- and bottle-fed, bottle feeding ceased between 3 and 4 years of age. Associations between nutritive and nonnutritive sucking behaviors and the malocclusions studied were analyzed by multiple binary logistic regression (α= 0.05. The frequencies of increased overjet were: 25.3% (G1, 38.8% (G2, 39.2% (G3 and 47.8% (G4. The percentages of Class 2 canine relationship were: 27.9% (G1, 48.8% (G2, 43.4% (G3 and 43% (G4. No significant effect of bottle feeding was found. The chances of diagnosing increased overjet (O.R. = 4.42, p < 0.001 and Class 2 canine relationship (O.R. = 4.02, p < 0.001 were greater for children with pacifier and/or digit-sucking habits, compared to those without a history of nonnutritive sucking behavior. It may be suggested that bottle feeding alone is not directly associated with higher prevalence rates of increased overjet and Class 2 canine relationship in the primary dentition.

  7. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria.

    Science.gov (United States)

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative.

  8. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria

    Science.gov (United States)

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Background: Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. Aim: To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Setting: Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. Materials and methods: The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. Results: A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Conclusion: Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative. PMID:21629570

  9. Micrometeorological measurements during the Blackmo 88 spray trials

    Science.gov (United States)

    D. E. Anderson; D. R. Miller; Y. S. Wang; W. E. Yendol; M. L. McManus

    1991-01-01

    Instrumentation was arrayed on a 120 foot tower to detail the local atmospheric conditions during the Blackmo 88 spray experiment. Measurements were continuous for 30 minute periods encompassing each spray pass.

  10. Numerical investigation on particle swelling in spray roasting reactors

    NARCIS (Netherlands)

    Schiemann, M; de Haan, A.B.; Wirtz, S.

    2016-01-01

    Spray roasting of metal chloride solutions is frequently used in steel industries to recover pickling liquids. As spray roasting reactors are difficult to characterize experimentally, computational fluid dynamics simu- lations have been used to investigate reactor performance. These simulations

  11. Numerical Study on Fan Spray for Gasoline Direct Injection Engines

    OpenAIRE

    Shirabe, Naotaka; Sato, Takaaki; Murase, Eiichi

    2003-01-01

    In gasoline direct injection engines, it is important to optimize fuel spray characteristics, which strongly affect stratified combustion process. Spray simulation is expected as a tool for optimizing the nozzle design. Conventional simulation method, how

  12. Spray Rolling Aluminum Strip for Transportation Applications

    Energy Technology Data Exchange (ETDEWEB)

    Kevin M. McHugh; Y. Lin; Y. Zhou; E. J. Lavernia; J.-P. Delplanque; S. B. Johnson

    2005-02-01

    Spray rolling is a novel strip casting technology in which molten aluminum alloy is atomized and deposited into the roll gap of mill rolls to produce aluminum strip. A combined experimental/modeling approach has been followed in developing this technology with active participation from industry. The feasibility of this technology has been demonstrated at the laboratory scale and it is currently being scaled-up. This paper provides an overview of the process and compares the microstructure and properties of spray-rolled 2124 aluminum alloy with commercial ingot-processed material

  13. SPIRT-NRC. Containment Spray Iodine Removal

    Energy Technology Data Exchange (ETDEWEB)

    Postma, A.K. [Benton City Technology, Washington, DC (United States); Sherry, R.R.; Tam, P.S. [United States Nuclear Regulatory Commission, Washington, DC (United States)

    1988-01-01

    SPIRT predicts the washout of airborne contaminants in containment vessels under postulated loss-of-coolant accident (LOCA) conditions. SPIRT calculates iodine removal constants (lambdas) for post-LOCA containment spray systems. It evaluates the effect of the spectrum of drop sizes emitted by the spray nozzles,the effect of drop coalescence, and the precise solution of the time-dependent diffusion equation. STEAM-67 routines are included for calculating the properties of steam and water according to the 1967 ASME Steam Tables.

  14. Study on plasma sprayed boron carbide coating

    Science.gov (United States)

    Zeng, Yi; Lee, Soo W.; Ding, Chuanxian

    2002-03-01

    The microstructure, phase composition, and mechanical properties of boron carbide coatings formed by atmospheric plasma spraying (APS) are studied in the present work. The boron carbide coating with high microhardness and low porosity could be produced by APS. The decomposition of boron carbide powder during the plasma spray process would result in the formation of the BxC phase and an increase of the carbon phase, which is confirmed by transmission electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction results.

  15. Assessment of metal contaminations leaching out from recycling plastic bottles upon treatments.

    Science.gov (United States)

    Cheng, Xiaoliang; Shi, Honglan; Adams, Craig D; Ma, Yinfa

    2010-08-01

    Heavy metal contaminants in environment, especially in drinking water, are always of great concern due to their health impact. Due to the use of heavy metals as catalysts during plastic syntheses, particularly antimony, human exposure to metal release from plastic bottles has been a serious concern in recent years. The aim and scope of this study were to assess metal contaminations leaching out from a series of recycling plastic bottles upon treatments. In this study, leaching concentrations of 16 metal elements were determined in 21 different types of plastic bottles from five commercial brands, which were made of recycling materials ranging from no. 1 to no. 7. Several sets of experiments were conducted to study the factors that could potentially affect the metal elements leaching from plastic bottles, which include cooling with frozen water, heating with boiling water, microwave, incubating with low-pH water, outdoor sunlight irradiation, and in-car storage. Heating and microwave can lead to a noticeable increase of antimony leaching relative to the controls in bottle samples A to G, and some even reached to a higher level than the maximum contamination level (MCL) of the US Environmental Protection Agency (USEPA) regulations. Incubation with low-pH water, outdoor sunlight irradiation, and in-car storage had no significant effect on antimony leaching relative to controls in bottle samples A to G, and the levels of antimony leaching detected were below 6 ppb which is the MCL of USEPA regulations. Cooling had almost no effect on antimony leaching based on our results. For the other interested 15 metal elements (Al, V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Ag, Cd, Ba, Tl, Pb), no significant leaching was detected or the level was far below the MCL of USEPA regulations in all bottle samples in this study. In addition, washing procedure did contribute to the antimony leaching concentration for polyethylene terephthalate (PET) bottles. The difference of antimony leaching

  16. Characterization of aqueous alcohol solutions in bottles with THz reflection spectroscopy

    DEFF Research Database (Denmark)

    Jepsen, Peter Uhd; Jensen, Jens K.; Møller, Uffe

    2008-01-01

    We demonstrate a method based on self-referenced THz time-domain spectroscopy for inspection of aqueous liquids, and in particular alcohol solutions, inside closed containers. We demonstrate that it is possible to determine the alcohol content of an aqueous solution, and that liquids can...... be classified as either harmless or inflammable. The method operates in reflection mode with the result that liquids opaque to THz radiation can be characterized with little influence of the bottle shape. The method works with plastic bottles as well as glass bottles, with absorption of THz radiation...

  17. Application of silicone based elastomers for manufacturing of Green Fiber Bottle

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    2017-01-01

    Due to ever-increasing demand of sustainable products, eco-friendly packaging solutions are findingtheir importance in the paper packaging industry [1]. Green Fiber Bottle (GFB) is an alternative toplastic, glass and metal based packaging for beverages. The manufacturing of paper bottle is a two......). To simulate the inflation action of the core, Yeoh’s model is used for modelling of W. Thestrength of the GFB is correlated with the pressure the bottle can hold and the cut off burst pressurefrom experiments is also reported in this work....

  18. Algal growth inhibition test in filled, closed bottles for volatile and sorptive materials

    DEFF Research Database (Denmark)

    Mayer, Philipp; Nyholm, Niels; Verbruggen, Eric M. J.

    2000-01-01

    , and the resulting dissolved CO2 concentration supported maximum algal growth rates without pH drift for algal densities up to 4 mg dry weight/L. Two-day toxicity tests with kerosene were performed with this new test design and compared with an open bottle test and with a closed bottle test with headspace. Exposure...... concentrations of the volatile fraction of kerosene decreased by 99% in the open test, by 77% in the closed flask test with headspace, and by 16% in the filled closed bottle test. Algal growth inhibition was observed at much lower additions of kerosene in the new test design because of the improved maintenance...

  19. Deodorant spray: a newly identified cause of cold burn.

    Science.gov (United States)

    May, Ulrich; Stirner, Karl-Heinz; Lauener, Roger; Ring, Johannes; Möhrenschlager, Matthias

    2010-09-01

    Two patients encountered a first-degree cold burn after use of a deodorant spray. The spray-nozzle to skin-surface distance was approximately 5 cm, and the spraying lasted approximately 15 seconds. Under laboratory conditions, the deodorant in use was able to induce a decline in temperature of >60 degrees C. These 2 cases highlight a little-known potential for skin damage by deodorant sprays if used improperly.

  20. Design of neutral particle incident heating apparatus for large scale helical apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Osamu; Oka, Yoshihide; Osakabe, Masaki; Takeiri, Yasuhiko; Tsumori, Katsuyoshi; Akiyama, Ryuichi; Asano, Eiji; Kawamoto, Toshikazu; Kuroda, Tsutomu [National Inst. for Fusion Science, Nagoya (Japan)

    1997-02-01

    In the Institute of Nuclear Fusion Science, construction of the large scale helical apparatus has been progressed favorably, and constructions of the heating apparatus as well as of electron resonance apparatus were begun in their orders under predetermined manner since 1994 fiscal year. And, on 1995 fiscal year, construction of neutral particle incident heating apparatus, leading heat apparatus, was begun under 3 years planning. The plasma heating study system adopted the study results developed in this institute through the large scale hydrogen negative ion source and also adopted thereafter development on nuclear fusion study by modifying the original specification set at the beginning of the research plan before 7 years. As a result, system design was changed from initial 125 KeV to 180 KeV in the beam energy and to execute 15 MW incidence using two sets beam lines, to begin its manufacturing. Here is described on its new design with reason of its modifications. (G.K.)