WorldWideScience

Sample records for spot test kits

  1. Exclusion of EDNRB and KIT as the basis for white spotting in Border Collies.

    Science.gov (United States)

    Metallinos, D; Rine, J

    2000-01-01

    White spotting patterns in mammals can be caused by mutations in the genes for the endothelin B receptor and c-Kit, whose protein products are necessary for proper migration, differentiation or survival of the melanoblast population of cells. Although there are many different dog breeds that segregate white spotting patterns, no genes have been identified that are linked to these phenotypes. An intercross was generated from a female Newfoundland and a male Border Collie and the white spotting phenotypes of the intercross progeny were evaluated by measuring percentage surface area of white in the puppies. The Border Collie markings segregated as a simple autosomal recessive (7/25 intercross progeny had the phenotype). Two candidate genes, for the endothelin B receptor (EDNRB) and c-Kit (KIT), were evaluated for segregation with the white spotting pattern. Polymorphisms between the Border Collie and Newfoundland were identified for EDNRB using Southern analysis after a portion of the canine gene had been cloned. Polymorphisms for KIT were identified using a microsatellite developed from a bacterial artificial chromosome containing the canine gene. Both EDNRB and KIT were excluded as a cause of the white spotting pattern in at least two of the intercross progeny. Although these genes have been implicated in white spotting in other mammals, including horses, pigs, cows, mice and rats, they do not appear to be responsible for the white spotting pattern found in the Border Collie breed of dog.

  2. Endogenous retrovirus insertion in the KIT oncogene determines white and white spotting in domestic cats.

    Science.gov (United States)

    David, Victor A; Menotti-Raymond, Marilyn; Wallace, Andrea Coots; Roelke, Melody; Kehler, James; Leighty, Robert; Eizirik, Eduardo; Hannah, Steven S; Nelson, George; Schäffer, Alejandro A; Connelly, Catherine J; O'Brien, Stephen J; Ryugo, David K

    2014-08-01

    The Dominant White locus (W) in the domestic cat demonstrates pleiotropic effects exhibiting complete penetrance for absence of coat pigmentation and incomplete penetrance for deafness and iris hypopigmentation. We performed linkage analysis using a pedigree segregating White to identify KIT (Chr. B1) as the feline W locus. Segregation and sequence analysis of the KIT gene in two pedigrees (P1 and P2) revealed the remarkable retrotransposition and evolution of a feline endogenous retrovirus (FERV1) as responsible for two distinct phenotypes of the W locus, Dominant White, and white spotting. A full-length (7125 bp) FERV1 element is associated with white spotting, whereas a FERV1 long terminal repeat (LTR) is associated with all Dominant White individuals. For purposes of statistical analysis, the alternatives of wild-type sequence, FERV1 element, and LTR-only define a triallelic marker. Taking into account pedigree relationships, deafness is genetically linked and associated with this marker; estimated P values for association are in the range of 0.007 to 0.10. The retrotransposition interrupts a DNAase I hypersensitive site in KIT intron 1 that is highly conserved across mammals and was previously demonstrated to regulate temporal and tissue-specific expression of KIT in murine hematopoietic and melanocytic cells. A large-population genetic survey of cats (n = 270), representing 30 cat breeds, supports our findings and demonstrates statistical significance of the FERV1 LTR and full-length element with Dominant White/blue iris (P < 0.0001) and white spotting (P < 0.0001), respectively. Copyright © 2014 David et al.

  3. Whole genome sequencing reveals a novel deletion variant in the KIT gene in horses with white spotted coat colour phenotypes.

    Science.gov (United States)

    Dürig, N; Jude, R; Holl, H; Brooks, S A; Lafayette, C; Jagannathan, V; Leeb, T

    2017-08-01

    White spotting phenotypes in horses can range in severity from the common white markings up to completely white horses. EDNRB, KIT, MITF, PAX3 and TRPM1 represent known candidate genes for such phenotypes in horses. For the present study, we re-investigated a large horse family segregating a variable white spotting phenotype, for which conventional Sanger sequencing of the candidate genes' individual exons had failed to reveal the causative variant. We obtained whole genome sequence data from an affected horse and specifically searched for structural variants in the known candidate genes. This analysis revealed a heterozygous ~1.9-kb deletion spanning exons 10-13 of the KIT gene (chr3:77,740,239_77,742,136del1898insTATAT). In continuity with previously named equine KIT variants we propose to designate the newly identified deletion variant W22. We had access to 21 horses carrying the W22 allele. Four of them were compound heterozygous W20/W22 and had a completely white phenotype. Our data suggest that W22 represents a true null allele of the KIT gene, whereas the previously identified W20 leads to a partial loss of function. These findings will enable more precise genetic testing for depigmentation phenotypes in horses. © 2017 Stichting International Foundation for Animal Genetics.

  4. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  5. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.

  6. Association of KIT exon 9 mutations with nongastric primary site and aggressive behavior: KIT mutation analysis and clinical correlates of 120 gastrointestinal stromal tumors.

    Science.gov (United States)

    Antonescu, Cristina R; Sommer, Gunhild; Sarran, Lisa; Tschernyavsky, Sylvia J; Riedel, Elyn; Woodruff, James M; Robson, Mark; Maki, Robert; Brennan, Murray F; Ladanyi, Marc; DeMatteo, Ronald P; Besmer, Peter

    2003-08-15

    Activating mutations of the KIT juxtamembrane region are the most common genetic events in gastrointestinal stromal tumors (GISTs) and have been noted as independent prognostic factors. The impact of KIT mutation in other regions, such as the extracellular or kinase domains, is not well-defined and fewer than 30 cases have been published to date. One hundred twenty GISTs, confirmed by KIT immunoreactivity, were evaluated for the presence of KIT exon 9, 11, 13, and 17 mutations. The relation between the presence/type of KIT mutation and clinicopathological factors was analyzed using Fisher's exact test and log-rank test. Forty-four % of the tumors were located in the stomach, 47% in the small bowel, 6% in the rectum, and 3% in the retroperitoneum. Overall, KIT mutations were detected in 78% of patients as follows: 67% in exon 11, 11% in exon 9, and none in exon 13 or 17. The types of KIT exon 11 mutations were heterogeneous and clustered in the classic "hot spot" at the 5' end of exon 11. Seven % of cases showed internal tandem duplications (ITD) at the 3' end of exon 11, in a region that we designate as a second hot spot for KIT mutations. Interestingly, these cases were associated with: female predominance, stomach location, occurrence in older patients, and favorable outcome. There were significant associations between exon 9 mutations and large tumor size (P < 0.001) and extragastric location (P = 0.02). Ten of these 13 patients with more than 1-year follow-up have developed recurrent disease. Most KIT-expressing GISTs show KIT mutations that are preferentially located within the classic hot spot of exon 11. In addition, we found an association between a second hot spot at the 3'end of exon 11, characterized by ITDs, and a subgroup of clinically indolent gastric GISTs in older females. KIT exon 9 mutations seem to define a distinct subset of GISTs, located predominantly in the small bowel and associated with an unfavorable clinical course.

  7. Iodobell in vivo kits for labelling with 123I or 131I

    International Nuclear Information System (INIS)

    Koernyei, J.; Horvath, M.; Pszota, A.; Lakatos, M.; Szirtes, L.

    1988-01-01

    Iodobell in vivo kits provide an easy and fast method for 'on the spot' radioiodination with 123 I (or 131 I). Until now three kits have been developed in the Institute of Isotopes Budapest, the heptadecanoic acid, the hippurate and the MIBG kits. From these, the heptadecanoic acid kit is being tested in humans in Hungary, the other two are under the registration procedure. The Iodobell in vivo kits may contribute to the application of 123 I radioisotope in Hungary. (orig.)

  8. Experience with Phadebas hCS (HPL)-Test kit

    International Nuclear Information System (INIS)

    Herter, U.

    1976-01-01

    The RIA determination of human placental lactogen (HPL) is described using the Phadebas test kit by Pharmacia, Sweden. The results of the test are shown graphically. The kit was tested over a period of one year and the tests were modified to meet the requirements of clinical examinations. The calibration curve is constant and applicable for a period of 14 days. The Phadebas kit has proved to be advantageous for both scientific research work and for routine clinical examinations. (L.O.)

  9. Statistical modeling of dental unit water bacterial test kit performance.

    Science.gov (United States)

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  10. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  11. [The comparison of two newborn cytomegalovirus IgG antibody screening ELISA kits].

    Science.gov (United States)

    Zhang, Shun-Xian; He, Xiao-Zhou; Wang, Shi-Wen; Wang, Xiao-Fang

    2013-10-01

    This study compared two newborn Cytomegalovirus (CMV) IgG antibody screening ELISA kits and evaluated the detection effectiveness of Abnova kit. CMV IgG antibodies were detected by both SeraQuest and Abnova kits from dried blood spot (DBS) samples of 488 newborn heel sticks. The detection abilities of these two kits were compared in different sample dilution concentrations. Relative detection effectiveness of the Abnova kit was defined by statistical method using the SeraQuest kit as a point of comparison. Compared to the SeraQuest screening test kit, the Abnova kit revealed a sensitivity of 98.9%, specificity of 78.6%, positive predictive value of 99.3%, negative predictive value of 68.8%, and the coincidence rate for these two screening test kits at 98.3%. The consistency check of both kits based on interpretation of the kappa statistic was relatively good. For the Abnova kit, the "area under the ROC curve" was 0.887, which indicates moderate accuracy. Abnova kit can be applied to newborn screening for congenital CMV infections. However, repeating the test for ambiguous results is suggested to increase the specificity and negative predictive value.

  12. Mononucleosis spot test

    Science.gov (United States)

    Monospot test; Heterophile antibody test; Heterophile agglutination test; Paul-Bunnell test; Forssman antibody test ... The mononucleosis spot test is done when symptoms of mononucleosis are ... Fatigue Fever Large spleen (possibly) Sore throat Tender ...

  13. A Frameshift Mutation in KIT is Associated with  White Spotting in the Arabian Camel

    Directory of Open Access Journals (Sweden)

    Heather Holl

    2017-03-01

    Full Text Available While the typical Arabian camel is characterized by a single colored coat, there are rare populations with white spotting patterns. White spotting coat patterns are found in virtually all domesticated species, but are rare in wild species. Theories suggest that white spotting is linked to the domestication process, and is occasionally associated with health disorders. Though mutations have been found in a diverse array of species, fewer than 30 genes have been associated with spotting patterns, thus providing a key set of candidate genes for the Arabian camel. We obtained 26 spotted camels and 24 solid controls for candidate gene analysis. One spotted and eight solid camels were whole genome sequenced as part of a separate project. The spotted camel was heterozygous for a frameshift deletion in KIT (c.1842delG, named KITW1 for White spotting 1, whereas all other camels were wild‐type (KIT+/KIT+. No additional mutations unique to the spotted camel were detected in the EDNRB, EDN3, SOX10, KITLG, PDGFRA, MITF, and PAX3 candidate white spotting genes. Sanger sequencing of the study population identified an additional five kITW1/KIT+ spotted camels. The frameshift results in a premature stop codon five amino acids downstream, thus terminating KIT at the tyrosine kinase domain. An additional 13 spotted camels tested KIT+/KIT+, but due to phenotypic differences when compared to the KITW1/KIT+ camels, they likely represent an independent mutation. Our study suggests that there are at least two causes of white spotting in the Arabian camel, the newly described KITW1 allele and an uncharacterized mutation.

  14. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  15. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PERFORMANCE TESTING OF THE INDUSTRIAL TEST SYSTEM, INC. CYANIDE REAGENTSTRIP™ TEST KIT

    Science.gov (United States)

    Cyanide can be present in various forms in water. The cyanide test kit evaluated in this verification study (Industrial Test System, Inc. Cyanide Regent Strip ™ Test Kit) was designed to detect free cyanide in water. This is done by converting cyanide in water to cyanogen...

  16. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  17. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  18. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  19. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  20. High explosive spot test analyses of samples from Operable Unit (OU) 1111

    Energy Technology Data Exchange (ETDEWEB)

    McRae, D.; Haywood, W.; Powell, J.; Harris, B.

    1995-01-01

    A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soil and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.

  1. Evaluation of a clinic-based cholinesterase test kit for the Washington State Cholinesterase Monitoring Program.

    Science.gov (United States)

    Hofmann, Jonathan N; Carden, Angela; Fenske, Richard A; Ruark, Harold E; Keifer, Matthew C

    2008-07-01

    The Washington State Cholinesterase Monitoring Program for pesticide handlers requires blood draws at local clinics, with samples tested at a central laboratory. At present, workers with inhibited cholinesterase activity may be re-exposed before they can be removed from work. In this study we explored the option of on-site testing at local clinics using the EQM Test-mate Kittrade mark, a portable cholinesterase test kit. Test kit cholinesterase activity measurements were performed on 50 blood samples by our research staff, and compared to measurements on the same samples by the Washington State Public Health Laboratory. Another set of samples was also analyzed with the test kit by medical staff at an eastern Washington clinic. Triplicate measurements with the test kit had a 3.3% average coefficient of variation (CV) for plasma cholinesterase (PChE), and a 3.5% average CV for erythrocyte cholinesterase (AChE) measurements. The kit's PChE measurements were similar to PHL measurements (average ratio of 0.98) when performed in the laboratory, but had a tendency to underestimate activity when used in the clinic setting (average ratio of 0.87). The kit systematically overestimated AChE activity by 42-48% relative to the PHL measurements, regardless of where the samples were analyzed. This easy-to-use test kit appeared to be a viable method for clinic-based PChE measurements, but was less consistent for AChE measurements performed in the clinic. Absolute measurements with the kit need to be evaluated carefully relative to standardized methods. (c) 2008 Wiley-Liss, Inc.

  2. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  3. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    OpenAIRE

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-01-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an i...

  4. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  5. Fabrication of CANFLEX bundle kit for irradiation test in NRU

    International Nuclear Information System (INIS)

    Cho, Moon Sung; Kwon, Hyuk Il; Ji, Chul Goo; Chang, Ho Il; Sim, Ki Seob; Suk, Ho Chun.

    1997-10-01

    CANFLEX bundle kit was prepared at KAERI for the fabrication of complete bundle at AECL. Completed bundle will be used for irradiation test in NRU. Provisions in the 'Quality Assurance Manual for HWR Fuel Projects,' 'Manufacturing Plan' and 'Quality Verification, Inspection and Test Plan' were implemented as appropriately for the preparation of CANFLEX kit. A set of CANFLEX kit consist of 43 fuel sheath of two different sizes with spacers, bearing pads and buttons attached, 2 pieces of end plates and 86 pieces of end caps with two different sizes. All the documents utilized as references for the fabrication such as drawings, specifications, operating instructions, QC instructions and supplier's certificates are specified in this report. Especially, suppliers' certificates and inspection reports for the purchased material as well as KAERI's inspection report are integrated as attachments to this report. Attached to this report are supplier's certificates and KAERI inspection reports for the procured materials and KAERI QC inspection reports for tubes, pads, spacers, buttons, end caps, end plates and fuel sheath. (author). 37 refs

  6. A Drosophila wing spot test

    International Nuclear Information System (INIS)

    Ayaki, Toshikazu; Yoshikawa, Isao; Niikawa, Norio; Hoshi, Masaharu.

    1986-01-01

    A Drosophila wing spot test system was used to investigate the effects of low doses of X-rays, gamma rays, and both 2.3 and 14.1 MeV neutrons on somatic chromosome mutation (SCM) induction. The incidence of SCM was significantly increased with any type of radiation, with evident linear dose-response relationship within the range of 3 to 20 cGy. It was estimated that relative biological effectiveness value for SCM induction of 2.3 MeV neutrons to X-rays and gamma rays is much higher than that of 14.1 MeV neutrons to those photons (2.4 vs 8.0). The Drosophila wing spot test system seems to become a promising in vivo experimental method for higher animals in terms of the lack of necessity for a marvelously large number of materials required in conventional test system. (Namekawa, K.)

  7. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    Science.gov (United States)

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some

  8. Nationwide study of factors associated with public's willingness to use home self-test kit for dengue fever in Malaysia.

    Science.gov (United States)

    Wong, Li Ping; Atefi, Narges; AbuBakar, Sazaly

    2016-08-12

    As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1) identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2) find out the characteristics of the test kits that influence the use of the dengue test kit. A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18-60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43-0.89; p = 0.02, vs. tertiary educational level) and secondary educational levels (OR: 0.73; 95 % CI: 0.57-0.90; p = 0.01, vs. tertiary educational level) were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0-5) were less likely (OR: 0.67, 95 % CI: 0.53-0.85, p dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10). Participants with a lower total dengue fever knowledge score (range 0-22) were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61-0.91, p = 0.001, vs. higher total dengue fever knowledge score) compared to those with a higher total dengue fever knowledge score (range 23-44). With response to

  9. Monitoring acetylcholinesterase levels in migrant agricultural workers and their children using a portable test kit.

    Science.gov (United States)

    Higgins, G M; Muñiz, J F; McCauley, L A

    2001-02-01

    The EQM Research, Inc., portable test kit was evaluated as a surveillance tool for blood cholinesterase levels among migrant workers and their children. Laboratory validation demonstrated a linear relationship between the reference Ellman and kit methods (Ellman = 0.95 x kit result + 0.82, r2 = 0.98). Pre- and post-season cholinesterase levels measured in 70 farm workers were within normal ranges, but significantly different at 28.5 and 29.7 U/g Hb, respectively (paired t-test, p = 0.014). Results from 98 migrant farm worker children and a comparison group of 53 age-matched non-agricultural children showed that cholinesterase levels were not significantly different between the agricultural and non-agricultural children (ANOVA, p = 0.69). These data demonstrate that a portable test kit can provide useful data pesticide exposures when measurements are made in a temperature-controlled setting.

  10. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  11. Innovative accountability of tracking test kit as locked resources: a lesson in a restricted resource setting.

    Science.gov (United States)

    Makuwani, Ahmad M; Msuya, Sia; Haule, Dunstan; Mogella, Deus; Nkya, Efesper

    2013-09-01

    To implement quality screening in a blood service requires the presence of screening strategy with a clear algorithm and supporting standard operating procedures (SOPs), skilled and motivated human resource to perform testing, infrastructure, regular available test kits, and other supplies. In developing countries, smooth supply chain management of critical transfusion transmissible infections (TTIs) screening reagents is a challenge. Therefore, managing the little available kits by knowing the rate of consumption, good forecasting, and monitoring expiry date may be a key in ensuring regular supply. Test kit monitoring tool (TKMT) for Vironostika HIV Uni-Form kit/192 1&2 Ag/Ab, Genedia kits for HBsAg and HCV, and RPR for syphilis was developed to track these reagents. This excel tool was developed to assess received reagents, quantity used, quantity remaining, and date of expiration. The tool was evaluated by assessing rerun for each test kits, match tests conducted with blood units tested, adherence to the principle of first in-first out (FIFO), and quantity remaining in the center against the need. The mean rerun for HIV ELISA Vironistika uniform II Ag/Ab observed over expected was 6.9% (n = 3.8) than 2.4% (n = 1.3), HBsAg was 9.9% (n = 5.7) than 6.7% (3.5) (expected), Genedia for HCV was 1.3% (n = 0.7) than 0.5% (n = 0.3), and RPR test for syphilis 3.3% (n = 1.5) than 0.5%. During implementation, TKMT managed to detect expiring kits in the zonal blood transfusion centers. A tool-like TKMT may capture other supplies within blood when expanded. Monitoring of supplies may enable blood service actual accounting and in forecasting supplies and reagents. © 2013 Wiley Periodicals, Inc.

  12. Clinical application of T-spot test of Mycobacterium tuberculosis infection for diagnosis of suspected pulmonary tuberculosis patients

    Directory of Open Access Journals (Sweden)

    Xue-ping SHI

    2017-11-01

    Full Text Available Objective To explore the application value of T-spot test of Mycobacterium tuberculosis infection (T-SPOT.TB on diagnosis and differential diagnosis of pulmonary tuberculosis. Methods From Apr. 2014 to Dec. 2016, 700 patients with suspected pulmonary tuberculosis were collected, venous blood (5ml was drawn off and sputum was collected from each patient separately for T-SPOT.TB and pathogens identification (including TB. Chest CT, bronchoscopy brush or biopsy histopathological examination were followed up, cultivation of My. tuberculosis and of common bacteria with sputum or lavage fluid when needed. T-SPOT.TB test was performed according to the kit instruction operation. 2.5×105 peripheral blood mononuclear cells (PBMCs were added into the pre- coated anti- human γ- interferon antibody, and co-incubated separately with two specific My. tuberculosis antigens, namely early secretory targeting 6 (ESAT-6 and culture filtration protein 10 (CFP-10, and then the spot forming cells (SFCs were counted. The gold standard for present study were set as follows: 1 My. tuberculosis smear positive or culture positive; 2 Clinical diagnosis (meet any one is positive. The efficacy of T-SPOT.TB on diagnosing active TB was observed, and then the optimal critical value for diagnosing active TB was determined. Patients diagnosed as active TB were divided into 4 subgroups: initial treatment group, retreatment group, smear or culture positive group, and smear or culture negative group. T-SPOT.TB was carried out to detect A and B antigen, and the difference of formed SFCs was then compared. The present study was approved by the Ethics Committee of Xinjiang Uygur Autonomous Region Chest Hospital. Results Of 700 cases suspected of pulmonary tuberculosis enrolled in present study, 528 out of 624 definite cases (84.6% were finally diagnosed as active tuberculosis (active TB group and 96 cases (15.4% were as without TB infection (non-TB group. Positive results of T-SPOT

  13. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Sean D Young

    Full Text Available Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM. Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits.African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience.Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience.Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  14. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Science.gov (United States)

    Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D

    2014-01-01

    Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  15. Reviews Toy: Air swimmers Book: Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Book: Physics Experiments for your Bag Book: Quantum Physics for Poets Equipment: SEP colour wheel kit Equipment: SEP colour mixing kit Software: USB DrDAQ App: iHandy Level Equipment: Photonics Explorer kit Web Watch

    Science.gov (United States)

    2012-01-01

    WE RECOMMEND Air swimmers Helium balloon swims like a fish Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Ballistics book hits the spot Physics Experiments for your Bag Handy experiments for your lessons Quantum Physics for Poets Book shows the economic importance of physics SEP colour wheel kit Wheels investigate colour theory SEP colour mixing kit Cheap colour mixing kit uses red, green and blue LEDs iHandy Level iPhone app superbly measures angles Photonics Explorer kit Free optics kit given to schools WORTH A LOOK DrDAQ DrDAQ software gets an upgrade WEB WATCH Websites show range of physics

  16. Nationwide study of factors associated with public’s willingness to use home self-test kit for dengue fever in Malaysia

    Directory of Open Access Journals (Sweden)

    Li Ping Wong

    2016-08-01

    Full Text Available Abstract Background As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1 identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2 find out the characteristics of the test kits that influence the use of the dengue test kit. Methods A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18–60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. Results From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43–0.89; p = 0.02, vs. tertiary educational level and secondary educational levels (OR: 0.73; 95 % CI: 0.57–0.90; p = 0.01, vs. tertiary educational level were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0–5 were less likely (OR: 0.67, 95 % CI: 0.53–0.85, p < 0.001, vs. higher perceived barriers to use a home self-testing dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10. Participants with a lower total dengue fever knowledge score (range 0–22 were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61–0.91, p = 0.001, vs. higher total dengue

  17. Thyroxine determination in serum by radioimmunoassay and competitive protein-binding analysis (simultaneous study using four test kits)

    International Nuclear Information System (INIS)

    Wagner, K.

    1978-01-01

    Three commercial test kits for radioimmunological T 4 -determination have been tested (T 4 -RIA Abbott, RIA-mat T 4 , T 4 -RIA Henning). The RIA method has also been compared with a CPBA test (Tetralute) for routine application. 1) The results show that CPBA (Tetralute) is superior over the three radioimmuno-assays with regard to intra-assay variance. The T 4 -RIA Abbott has been inferior to the two other RIA under test and to the Tetralute with regard to inter-assay variance. 2) The four test kits show significant differences and considerable deviations from the given nominal values in comparison with the mean values of two control sera. A control for correctness does not seem to be appropriate as it cannot be decided which of the test kits yields the true value of T 4 content. No systematic difference has been observed between RIA and CPBA in the determination of T 4 in control sera. 3) No detectable difference has been found among the RIA-T 4 test kits and comparing them with the CBPA test regarding their diagnostic precision. A good correlation of T 4 values of euthyroid patients comparing the Tetralute and the three radioimmunological test kits. The mean values of euthyroid sera obtained by the three radioimmuno-assays and the Tetralute are not in agreement with each other. (orig.) [de

  18. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  19. Determination of total galactose from dried blood spots—extensive assay evaluation of a CE-marked test-kit

    OpenAIRE

    Fingerhut, R; Torresani, T

    2013-01-01

    Most newborn screening laboratories use CE-marked or FDA-approved test-kits, like in routine clinical chemistry. National regulations require only minimal evaluation from the customer, if the test-kits are used as specified by the manufacturer. The microtiter-based kit-concept is often based on the perception, that the laboratory always processes whole microtiter plates. However, in the daily routine, this is rather a rare exception, which leads to much higher costs per newborn, compared to t...

  20. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  1. Mutagenicity studies with the mouse spot test

    Energy Technology Data Exchange (ETDEWEB)

    Gocke, E.; Wild, D.; Eckhardt, K.; King, M.T.

    1983-04-01

    The mammalian spot test, which detects somatic gene mutations in mouse embryos, was investigated with selected chemicals to (a) further validate this test system ethylnitrosourea, ethyl methanesulfonate, 2-acetylaminofluorene and colchicine (ENU, EMS, 2AAF), and (b) evaluate the mutagenic potential, in a whole-mammal system, of environmental compounds that had been previously recognized as mutagens in other mammalian or submammalian test systems (1,2-dichloroethane, hydroquinone, nitrofurantoin, o-phenylenediamine, fried sausage extract). Of these substances, ENU, EMS and 2AAF were significantly mutagenic, 1,2-dichloroethane was probably weakly mutagenic. The ENU data were used to estimate the number of pigment precursor cells present at the time of treatment (day 9.25). We also describe in this report the use of a fluorescence microscope for classification of hairs from spots on the coat of C57BL/6JHan X T hybrids.

  2. First Beam Test of Nanometer Spot Size Monitor Using Laser Interferometry

    CERN Document Server

    Walz, D

    2003-01-01

    The nanometer spot size monitor based on the laser interferometry (Laser-Compton Spot Size Monitor) has been tested in FFTB beam line at SLAC. A low emittance beam of 46 GeV electrons, provided by the two-mile linear accelerator, was focused into nanometer spot in the FFTB line, and its transverse dimensions were precisely measured by the spot size monitor.

  3. First Beam Test of Nanometer Spot Size Monitor Using Laser Interferometry

    International Nuclear Information System (INIS)

    Walz, Dieter R

    2003-01-01

    The nanometer spot size monitor based on the laser interferometry (Laser-Compton Spot Size Monitor) has been tested in FFTB beam line at SLAC. A low emittance beam of 46 GeV electrons, provided by the two-mile linear accelerator, was focused into nanometer spot in the FFTB line, and its transverse dimensions were precisely measured by the spot size monitor

  4. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  5. Benchmarking Tool Kit.

    Science.gov (United States)

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  6. Spot test kit for explosives detection

    Science.gov (United States)

    Pagoria, Philip F; Whipple, Richard E; Nunes, Peter J; Eckels, Joel Del; Reynolds, John G; Miles, Robin R; Chiarappa-Zucca, Marina L

    2014-03-11

    An explosion tester system comprising a body, a lateral flow membrane swab unit adapted to be removeably connected to the body, a first explosives detecting reagent, a first reagent holder and dispenser operatively connected to the body, the first reagent holder and dispenser containing the first explosives detecting reagent and positioned to deliver the first explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body, a second explosives detecting reagent, and a second reagent holder and dispenser operatively connected to the body, the second reagent holder and dispenser containing the second explosives detecting reagent and positioned to deliver the second explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body.

  7. Forgotten evidence: A mixed methods study of why sexual assault kits (SAKs) are not submitted for DNA forensic testing.

    Science.gov (United States)

    Campbell, Rebecca; Fehler-Cabral, Giannina; Bybee, Deborah; Shaw, Jessica

    2017-10-01

    Throughout the United States, hundreds of thousands of sexual assault kits (SAKs) (also termed "rape kits") have not been submitted by the police for forensic DNA testing. DNA evidence can help sexual assault investigations and prosecutions by identifying offenders, revealing serial offenders through DNA matches across cases, and exonerating those who have been wrongly accused. In this article, we describe a 5-year action research project conducted with 1 city that had large numbers of untested SAKs-Detroit, Michigan-and our examination into why thousands of rape kits in this city were never submitted for forensic DNA testing. This mixed methods study combined ethnographic observations and qualitative interviews to identify stakeholders' perspectives as to why rape kits were not routinely submitted for testing. Then, we quantitatively examined whether these factors may have affected police practices regarding SAK testing, as evidenced by predictable changes in SAK submission rates over time. Chronic resource scarcity only partially explained why the organizations that serve rape victims-the police, crime lab, prosecution, and victim advocacy-could not test all rape kits, investigate all reported sexual assaults, and support all rape survivors. SAK submission rates significantly increased once criminal justice professionals in this city had full access to the FBI DNA forensic database Combined DNA Index System (CODIS), but even then, most SAKs were still not submitted for DNA testing. Building crime laboratories' capacities for DNA testing and training police on the utility of forensic evidence and best practices in sexual assault investigations can help remedy, and possibly prevent, the problem of untested rape kits. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Perceived Cost Advantages and Disadvantages of Purchasing HIV Self-Testing Kits among Urban Tanzanian Men: An Inductive Content Analysis.

    Science.gov (United States)

    Jennings, Larissa; Conserve, Donaldson F; Merrill, Jamison; Kajula, Lusajo; Iwelunmor, Juliet; Linnemayr, Sebastian; Maman, Suzanne

    2017-08-01

    Impoverished men have lower rates of facility-based HIV counseling and testing and higher unknown HIV-positive status than women. Economic theory suggests that individuals will obtain an HIV test if anticipated benefits are greater than anticipated costs. Yet, few studies have investigated the range of financial preferences of HIV self-testing (HIVST) among poor men who decline testing or do not test regularly. Twenty-three interviews were conducted to qualitatively assess perceived costs saved and costs incurred from use of HIVST kits in infrequently- or never-tested Tanzanian men. All men were shown an HIVST kit and video. They were then asked about the costs associated with provider-led HIV testing, financial benefits and concerns of HIVST and willingness to pay for HIVST. Data were transcribed, coded and analyzed using inductive content analyses. We then grouped codes into perceived cost advantages and disadvantages and tabulated the range of prices men were willing to pay for a self-test kit. Perceived cost advantages of HIVST were avoidance of spending money to test in facilities, omission of follow-up fees, affordability relative to private clinics, and increased time for earning income and other activities. Men also discussed the imbalance of the financial benefit of accessing free, public HIV testing with the resources spent for transport, purchasing meals away from home and long wait lines. Perceived cost disadvantages of HIVST were prohibitive kit costs, required prior savings to purchase kits, expenditures relating to death and preferences for free provider-performed testing. Men were also concerned about the psychological costs of inaccurate results. HIVST willingness to pay varied among men. Men's decisions to self-test for HIV takes into account expected financial gains and losses. Demand generation for HIVST among men should consider use of low fees or free HIVST, while emphasizing potential savings from reduced travel, clinical costs, or time way

  9. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  10. Tailgate test kit for determining appropriate sediment reducing chemicals and dose rates : final report.

    Science.gov (United States)

    2017-07-01

    This study develops a Tailgate Test Kit to be used in the field to test flocculants for reducing turbidity in construction stormwater discharge. Turbidity of stormwater runoff at construction sites varies depending on which site soils are exposed to ...

  11. Diagnosis efficiency of urine malaria test kit for the diagnosis of ...

    African Journals Online (AJOL)

    The aim of this study was to determine the diagnostic efficiencies of urine malaria test kit with microscopy as the gold standard in detecting Plasmodium falciparum HRP-2, a poly-histidine antigen in urine of febrile patients. The study was conducted in a primary and secondary health institution in Gombe Town, Gombe State, ...

  12. Self-Test Kit: Rapid Diagnosis of Urogenital Infections in Military Women

    Science.gov (United States)

    1999-09-01

    this project will result in a self-test kit for use on deployment and/or in other resource poor environments. 14. SUBJECT TERMS 15. N1 tUMER OF PAGES...DK, et al. Characteristics of women by smoking status in the San Francisco Bay Area. Cancer Epidemiology, Biomarkers and Prevention, 1992; 1:491-7. 10

  13. THE CAUSALITY TEST BETWEEN THE VARIANCES OF SPOT AND FUTURE MARKET PRICES

    Directory of Open Access Journals (Sweden)

    EMRAH İSMAİL ÇEVİK

    2013-06-01

    Full Text Available Volatility in financial markets urges importance of risk management with respect to investors and especially firms. Information and interaction between spot and futures markets plays an important role on formation of market prices. In this study, causality and information flows are examined on spot and futures prices of ISE 100 Index, US Dollar, and Euro which are traded at Turkish Derivatives Exchange (VOB. Dynamic causality test that is originally created by Cheung and Ng (1996 is applied. Dynamic causality test results show that in the ISE 100 Index model spot prices affect futures prices and in the exchange model futures prices affect spot prices.

  14. The clinical testing of a Hungarian-made triiodothyronine radioimmunoassay kit

    International Nuclear Information System (INIS)

    Gyertyanfy, G.; Foeldes, J.

    1981-01-01

    The parameters of the calibration curve of the new Hungarian RK-11 kit for the determination of the total T3 content of the serum and the reliability of the results were studied. The data of the measurements made on a number of patients by RK-11, Biodata and Byk-Mallinckrodt kits were compared. The new kit seems to be applicable to the determination of the total T3 content in the serum. (author)

  15. Multicentre evaluation of commercial kit methods

    DEFF Research Database (Denmark)

    Gram, J; Declerck, P J; Sidelmann, Johannes Jakobsen

    1993-01-01

    In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved in...... of the plasma samples, which was PAI-1 depleted. The laboratories involved in the testing reported for this sample a mean value of 6.1 IU/ml.(ABSTRACT TRUNCATED AT 250 WORDS)......In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved...... in the production of data from each of the commercial kits tested. A considerable variation of PAI activity results reported from the laboratories testing the same commercial kits was observed. The range of reported results could in individual samples exceed the median value indicating an interlaboratory variation...

  16. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  17. The charging security study of electric vehicle charging spot based on automatic testing platform

    Science.gov (United States)

    Li, Yulan; Yang, Zhangli; Zhu, Bin; Ran, Shengyi

    2018-03-01

    With the increasing of charging spots, the testing of charging security and interoperability becomes more and more urgent and important. In this paper, an interface simulator for ac charging test is designed, the automatic testing platform for electric vehicle charging spots is set up and used to test and analyze the abnormal state during the charging process. On the platform, the charging security and interoperability of ac charging spots and IC-CPD can be checked efficiently, the test report can be generated automatically with No artificial reading error. From the test results, the main reason why the charging spot is not qualified is that the power supply cannot be cut off in the prescribed time when the charging anomaly occurs.

  18. Validation of a commercial insulated isothermal PCR-based POCKIT test for rapid and easy detection of white spot syndrome virus infection in Litopenaeus vannamei.

    Directory of Open Access Journals (Sweden)

    Yun-Long Tsai

    Full Text Available Timely pond-side detection of white spot syndrome virus (WSSV plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR, and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction. The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV, monodon baculovirus (MBV, and hepatopancreatic parvovirus (HPV positive samples. Accuracy analysis using 700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61-95.56% and specificity 97% (95% CI: 94.31-98.50%. Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei.

  19. Field kit and method for testing for the presence of gunshot residue

    Science.gov (United States)

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  20. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Jellesen, Morten Stendahl

    2015-01-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit...... exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release...

  1. The light spot test: Measuring anxiety in mice in an automated home-cage environment.

    Science.gov (United States)

    Aarts, Emmeke; Maroteaux, Gregoire; Loos, Maarten; Koopmans, Bastijn; Kovačević, Jovana; Smit, August B; Verhage, Matthijs; Sluis, Sophie van der

    2015-11-01

    Behavioral tests of animals in a controlled experimental setting provide a valuable tool to advance understanding of genotype-phenotype relations, and to study the effects of genetic and environmental manipulations. To optimally benefit from the increasing numbers of genetically engineered mice, reliable high-throughput methods for comprehensive behavioral phenotyping of mice lines have become a necessity. Here, we describe the development and validation of an anxiety test, the light spot test, that allows for unsupervised, automated, high-throughput testing of mice in a home-cage system. This automated behavioral test circumvents bias introduced by pretest handling, and enables recording both baseline behavior and the behavioral test response over a prolonged period of time. We demonstrate that the light spot test induces a behavioral response in C57BL/6J mice. This behavior reverts to baseline when the aversive stimulus is switched off, and is blunted by treatment with the anxiolytic drug Diazepam, demonstrating predictive validity of the assay, and indicating that the observed behavioral response has a significant anxiety component. Also, we investigated the effectiveness of the light spot test as part of sequential testing for different behavioral aspects in the home-cage. Two learning tests, administered prior to the light spot test, affected the light spot test parameters. The light spot test is a novel, automated assay for anxiety-related high-throughput testing of mice in an automated home-cage environment, allowing for both comprehensive behavioral phenotyping of mice, and rapid screening of pharmacological compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Experimental Study of Tensile Test in Resistance Spot Welding Process

    Directory of Open Access Journals (Sweden)

    Lebbal Habib

    Full Text Available Abstract Resistance spot welding (RSW is a widely used joining process for fabricating sheet metal assemblies in automobile industry .In comparison with other welding processes the RSW is faster and easier for automation. This process involves electrical, thermal and mechanical interactions. Resistance spot welding primarily takes place by localized melting spot at the interface of the sheets followed by its quick solidification under sequential control of pressure water-cooled electrode and flow of required electric current for certain duration. In this work the tensile tests were studied, the results obtained show that the type material, the overlap length, the angle of the rolling direction and the thickness of the sheet have an influence in resistance spot welding process.

  3. Preappointment testing for BRAF/KIT mutation in advanced melanoma: a model in molecular data delivery for individualized medicine.

    Science.gov (United States)

    Mounajjed, Taofic; Brown, Char L; Stern, Therese K; Bjorheim, Annette M; Bridgeman, Andrew J; Rumilla, Kandelaria M; McWilliams, Robert R; Flotte, Thomas J

    2014-11-01

    The emergence of individualized medicine is driven by developments in precision diagnostics, epitomized by molecular testing. Because treatment decisions are being made based on such molecular data, data management is gaining major importance. Among data management challenges, creating workflow solutions for timely delivery of molecular data has become pivotal. This study aims to design and implement a scalable process that permits preappointment BRAF/KIT mutation analysis in melanoma patients, allowing molecular results necessary for treatment plans to be available before the patient's appointment. Process implementation aims to provide a model for efficient molecular data delivery for individualized medicine. We examined the existing process of BRAF/KIT testing in melanoma patients visiting our institution for oncology consultation. We created 5 working groups, each designing a specific segment of an alternative process that would allow preappointment BRAF/KIT testing and delivery of results. Data were captured and analyzed to evaluate the success of the alternative process. For 1 year, 35 (59%) of 55 patients had prior BRAF/KIT testing. The remaining 20 patients went through the new process of preappointment testing; results were available at the time of appointment for 12 patients (overall preappointment results availability, 85.5%). The overall process averaged 13.4 ± 4.7 days. In conclusion, we describe the successful implementation of a scalable workflow solution that permits preappointment BRAF/KIT mutation analysis and result delivery in melanoma patients. This sets the stage for further applications of this model to other conditions, answering an increasing demand for robust delivery of molecular data for individualized medicine. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Comparative studies of commercially available T4-RIA-kits. Pt. 2

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Lipke, P.

    1978-01-01

    The investigation of the tested commercially available T 4 -RIA-Kits have shown that: The separation of hypo-, eu- and hyperthyroid values is better with kits a) and f) than with b), c), d) and e), though all kits give acceptable values under routine operating conditions, kit b) takes less time and work than the other tested kits, depending on the kit used, the time needed for 100 determinations varies between 1,5 and 4 hr. A general recommendation for one of the tested T 4 -RIA-Kits cannot be made since the choice of a kit depends not only on the criteria discussed but also on local circumstances. (orig.) [de

  5. Community-Based Colorectal Cancer Screening in a Rural Population: Who Returns Fecal Immunochemical Test (FIT) Kits?

    Science.gov (United States)

    Crosby, Richard A; Stradtman, Lindsay; Collins, Tom; Vanderpool, Robin

    2017-09-01

    To determine the return rate of community-delivered fecal immunochemical test (FIT) kits in a rural population and to identify significant predictors of returning kits. Residents were recruited in 8 rural Kentucky counties to enroll in the study and receive an FIT kit. Of 345 recruited, 82.0% returned an FIT kit from the point of distribution. These participants were compared to the remainder relative to age, sex, marital status, having an annual income below $15,000, not graduating from high school, not having a regular health care provider, not having health care coverage, being a current smoker, indicating current overweight or obese status, and a scale measure of fatalism pertaining to colorectal cancer. Predictors achieving significance at the bivariate level were entered into a stepwise logistic regression model to calculate adjusted OR and 95% CI. The return rate was 82.0%. In adjusted analyses, those indicating an annual income of less than $15,000 were 2.85 times more likely to return their kits (95% CI: 1.56-5.24; P < .001). Also, those not perceiving themselves to be overweight/obese were 1.95 times more likely to return their kits (95% CI: 1.07-3.55; P = .029). An outreach-based colorectal cancer screening program in a rural population may yield high return rates. People with annual incomes below $15,000 and those not having perceptions of being overweight/obese may be particularly likely to return FIT kits. © 2016 National Rural Health Association.

  6. Irradiated cocoa tested in the wing spot assay in Drosophila melanogaster

    International Nuclear Information System (INIS)

    Zimmering, S.; Olvera, O.; Cruces, M.P.; Pimentel, E.; Arceo, C.; Rosa, M.E. de la; Guzman, J.

    1992-01-01

    The result of treatment of Drosophila melanogaster with irradiated cocoa as scored in the somatic wing spot test is described. The test has been used previously in the evaluation of irradiated food and has registrated a significantly greater number of positives among chemicals tested than germ line counterparts. Irradiated cocoa has thus far been reported negative in other mutagenicity assays including those employing salmonella and Drosophila germ cells and mammalian cells. The wing spot test as described in Graf et al. was employed. Females of the genotype mwh were mated with flr 3 /TM3; Ser males. (author). 9 refs.; 1 tab

  7. Analytic laboratory performance of a point of care urine culture kit for diagnosis and antibiotic susceptibility testing.

    Science.gov (United States)

    Bongard, E; Frimodt-Møller, N; Gal, M; Wootton, M; Howe, R; Francis, N; Goossens, H; Butler, C C

    2015-10-01

    Currently available point-of-care (POC) diagnostic tests for managing urinary tract infections (UTIs) in general practice are limited by poor performance characteristics, and laboratory culture generally provides results only after a few days. This laboratory evaluation compared the analytic performance of the POC UK Flexicult(™) (Statens Serum Institut) (SSI) urinary kit for quantification, identification and antibiotic susceptibility testing and routine UK National Health Service (NHS) urine processing to an advanced urine culture method. Two hundred urine samples routinely submitted to the Public Health Wales Microbiology Laboratory were divided and: (1) analysed by routine NHS microbiological tests as per local laboratory standard operating procedures, (2) inoculated onto the UK Flexicult(™) SSI urinary kit and (3) spiral plated onto Colorex Orientation UTI medium (E&O Laboratories Ltd). The results were evaluated between the NHS and Flexicult(™ )methods, and discordant results were compared to the spiral plating method. The UK Flexicult(™) SSI urinary kit was compared to routine NHS culture for identification of a pure or predominant uropathogen at ≥ 10(5) cfu/mL, with a positive discordancy rate of 13.5% and a negative discordancy rate of 3%. The sensitivity and specificity were 86.7% [95% confidence interval (CI) 73.8-93.7] and 82.6% (95% CI 75.8-87.7), respectively. The UK Flexicult(™) SSI urinary kit was comparable to routine NHS urine processing in identifying microbiologically positive UTIs in this laboratory evaluation. However, the number of false-positive samples could lead to over-prescribing of antibiotics in clinical practice. The Flexicult(™) SSI kit could be useful as a POC test for UTIs in primary care but further pragmatic evaluations are necessary.

  8. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.

    Science.gov (United States)

    Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P

    2015-11-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Sensitivity and specificity of the nickel spot (dimethylglyoxime) test

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Skare, Lizbet; Lundgren, Lennart

    2010-01-01

    The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate nickel release around...

  10. 49 CFR 173.161 - Chemical kits and first aid kits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  11. Core Flight System Satellite Starter Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — The Core Flight System Satellite Starter Kit (cFS Kit) will allow a small satellite or CubeSat developer to rapidly develop, deploy, test, and operate flight...

  12. Elastodynamic spot testing - assessing serviceability of aging elastomer parts

    International Nuclear Information System (INIS)

    Gracie, B.; Metcalfe, R.; Wensel, R.

    1995-01-01

    The properties of all polymers change with time as a function of their environment. Traditional practice has been to replace these parts according to generic time limits based on estimates of worst case material properties and conditions. This is overly-conservative in many cases, and creates unnecessary maintenance work and costs for replacement and disposal. Much of this could be avoided if the serviceability of elastomeric parts such as seals, diaphragms, gaskets, cable insulation and hoses could be reassessed on a routine basis. Elastodynamic spot testing offers a way to do this. Parts can be sampled while in service or storage to compare their as-new and used (or aged) elastodynamic properties. This data can usually be correlated with the results of functional tests to prove that material properties have not degraded to the point where the part could fail. This spot testing is similar to a micro-hardness test, but includes stress-relaxation and subsequent recovery. It provides a nondestructive means to assess the effective age of the material at a point, or several points, on a part. Sampling of hardness alone is rarely sufficient to know whether a part is still functional because this overlooks the material's viscoelastic and strength properties. An elastodynamic spot tester has been used to test different sizes, shapes and hardnesses of elastomeric parts at different levels of strain, i.e., indentation depths. An initial test program has given informative relaxation and recovery data, showing repeatability and comparing well with finite element analysis of the indentation process. Tests of aged 0-rings and diaphragms have revealed different elastodynamic properties, depending on the elastomer compound and aging conditions. (author)

  13. Sensitivity and specificity of the nickel spot (dimethylglyoxime) test.

    Science.gov (United States)

    Thyssen, Jacob P; Skare, Lizbet; Lundgren, Lennart; Menné, Torkil; Johansen, Jeanne D; Maibach, Howard I; Lidén, Carola

    2010-05-01

    The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate nickel release around the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test. To evaluate the sensitivity and specificity of the DMG test. DMG spot testing, chemical analysis according to the EN 1811 reference method, and X-ray fluorescence spectroscopy (XRF) were performed concomitantly on 96 metallic components from earrings recently purchased in San Francisco. The sensitivity of the DMG test was 59.3% and the specificity was 97.5% based on DMG-test results and nickel release concentrations determined by the EN 1811 reference method. The DMG test has a high specificity but a modest sensitivity. It may serve well for screening purposes. Past exposure studies may have underestimated nickel release from consumer items.

  14. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    Science.gov (United States)

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  15. Advantage of using a home-made elisa kit for detection of Helicobacter pylori infection over commercially imported kits

    Directory of Open Access Journals (Sweden)

    Mohammadi M

    2008-01-01

    Full Text Available Purpose: To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp infection and comparison of its immunologic criteria with those of foreign commercial kits. Methods: A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. Results: The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%, BIOHIT kit (72.4, 41.6 and 94.1% and HelicoBlot2.1 (94.2, 93.4 and 100%. Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Conclusions: Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  16. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    Science.gov (United States)

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-09-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an in-frame insertion, Gly-Asn-Asn-Lys, within the extracellular domain, was detected in murine mast cell cultures and mid-gestation placenta. Both Kit+ and KitA+ isoforms showed increased autophosphorylation and enhanced association with phosphatidylinositol (PI) 3' kinase and PLC gamma 1, when stimulated with recombinant soluble Steel factor. No association or increase in phosphorylation of GAP and two GAP-associated proteins, p62 and p190, was observed. The two isoforms had distinct activities in the absence of exogenous soluble Steel factor; Kit+, but not KitA+, showed constitutive tyrosine phosphorylation that was accompanied by a low constitutive level of association with PI-3' kinase and PLC gamma 1. Introduction of the point substitutions associated with W37 (Glu582----Lys) or W41 (Val831----Met) mutant alleles into c-kit expression constructs abolished (W37) or reduced (W41) the Steel factor-induced association of the Kit receptor with signalling proteins in a manner proportional to the overall severity of the corresponding W mutant phenotype. These data suggest a diversity of normal Kit signalling pathways and indicate that W mutant phenotypes result from primary defects in the Kit receptor that affect its interaction with cytoplasmic signalling proteins.

  17. Nondestructive Testing of Ceramic Hip Joint Implants with Laser Spot Thermography

    Directory of Open Access Journals (Sweden)

    Roemer J.

    2017-12-01

    Full Text Available The paper presents an application of laser spot thermography for damage detection in ceramic samples with surface breaking cracks. The measurement technique is an active thermographic approach based on an external heat delivery to a test sample, by means of a laser pulse, and signal acquisition by an infrared camera. Damage detection is based on the analysis of surface temperature distribution near the exciting laser spot. The technique is nondestructive, non-contact and allows for full-field measurements. Surface breaking cracks are a very common type of damage in ceramic materials that are introduced in the manufacturing process or during the service period. This paper briefly discusses theoretical background of laser spot thermography, describes the experimental test rig and signal processing methods involved. Damage detection results obtained with laser spot thermography are compared with reference measurements obtained with vibrothermography. This is a different modality of active thermography, that has been previously proven effective for this type of damage. We demonstrate that both measurement techniques can be effectively used for damage detection and quality control applications of ceramic materials.

  18. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  19. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  20. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    Science.gov (United States)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of

  1. eTEST: Developing a Smart Home HIV Testing Kit that Enables Active, Real-Time Follow-Up and Referral After Testing.

    Science.gov (United States)

    Wray, Tyler; Chan, Philip A; Simpanen, Erik; Operario, Don

    2017-05-08

    Men who have sex with men (MSM) are the group at highest risk for contracting human immunodeficiency virus (HIV) in the United States, but many do not test as frequently as recommended. Home-based self-testing (HBST) for HIV holds promise for promoting regular testing among these individuals, but currently available HBSTs have limited follow-up options, providing only a 1-800 number that participants can call. Failure to actively conduct follow-up counseling and referrals after HBST use could result in delays in seeking confirmatory testing and care among users receiving reactive (preliminary positive) test results. HBST also fails to connect users who test negative with other prevention services that can reduce their future risk for HIV. The aim of our study was to use qualitative research methods with high-risk MSM to inform development of a "smart" HBST kit. The kit utilizes existing Internet-of-Things (IoT) technologies to monitor HBST use in real-time and enable delivery of timely, active follow-up counseling and referrals over the phone. In phase 1, individual interviews (n=10) explored how participants might use HBST and their views and preferences for conducting counseling and referral after HBST. Based on these perspectives, we developed a smartphone app (iOS, Android) that uses data from light sensors on Bluetooth low energy (BLE) beacons to monitor when HBST kits are opened, facilitating timely follow-up phone contact with users. In phase 2, a usability study conducted among high-risk MSM (n=10) examined the acceptability and feasibility of this system and provided user perspectives after using the system along with HBST. Phase 1 themes suggested that MSM preferred HBST, that most thought active follow-up after HBST would be valuable, and that doing so over the phone within 24 h after testing was preferable. Phase 2 results showed that the eTEST system successfully detected HBST use in nearly all cases. Participant perspectives also suggested that the

  2. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  3. Correlates of requesting home HIV self-testing kits on online social networks among African-American and Latino men who have sex with men.

    Science.gov (United States)

    Chiu, ChingChe J; Young, Sean D

    2016-01-01

    High levels of HIV stigma are one of the main difficulties in engaging African-American and Latino men who have sex with men (MSM) in HIV testing. The availability of home HIV test and the possibility of self-testing in private may improve uptake and counteract stigma. This paper sought to determine the correlates of requesting home HIV test kits among a sample of MSM social media users. The odds of participants requesting a test kit were significantly associated with using social networks to seek sexual partners (aOR: 2.47, 95% CI: 1.07-6.06) and thinking it is easier to use social networks for seeking sexual partners (1.87, 1.2-3.12), uncertain HIV status (4.29, 1.37-14.4), and having sex under the influence of alcohol (2.46, 1.06-5.77). Participants who had not been tested for more than 6 months were more likely to request a test kit than those who were tested in the past 6 months (2.53, 1.02-6.37). Participants who frequently talked to others about having sex with men online were less likely to request a test kit (0.73, 0.56-0.92). By reaching people over social media and offering them access to test kits, we were able to reach at-risk individuals who were uncertain about their HIV status and had not been regularly tested. The findings of the study will help to inform future HIV testing interventions.

  4. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    Science.gov (United States)

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  5. Platinum coat color in red fox (Vulpes vulpes) is caused by a mutation in an autosomal copy of KIT.

    Science.gov (United States)

    Johnson, J L; Kozysa, A; Kharlamova, A V; Gulevich, R G; Perelman, P L; Fong, H W F; Vladimirova, A V; Oskina, I N; Trut, L N; Kukekova, A V

    2015-04-01

    The red fox (Vulpes vulpes) demonstrates a variety of coat colors including platinum, a common phenotype maintained in farm-bred fox populations. Foxes heterozygous for the platinum allele have a light silver coat and extensive white spotting, whereas homozygosity is embryonic lethal. Two KIT transcripts were identified in skin cDNA from platinum foxes. The long transcript was identical to the KIT transcript of silver foxes, whereas the short transcript, which lacks exon 17, was specific to platinum. The KIT gene has several copies in the fox genome: an autosomal copy on chromosome 2 and additional copies on the B chromosomes. To identify the platinum-specific KIT sequence, the genomes of one platinum and one silver fox were sequenced. A single nucleotide polymorphism (SNP) was identified at the first nucleotide of KIT intron 17 in the platinum fox. In platinum foxes, the A allele of the SNP disrupts the donor splice site and causes exon 17, which is part of a segment that encodes a conserved tyrosine kinase domain, to be skipped. Complete cosegregation of the A allele with the platinum phenotype was confirmed by linkage mapping (LOD 25.59). All genotyped farm-bred platinum foxes from Russia and the US were heterozygous for the SNP (A/G), whereas foxes with different coat colors were homozygous for the G allele. Identification of the platinum mutation suggests that other fox white-spotting phenotypes, which are allelic to platinum, would also be caused by mutations in the KIT gene. © 2015 Stichting International Foundation for Animal Genetics.

  6. Precision for Smallholder Farmers: A Small-Scale-Tailored Variable Rate Fertilizer Application Kit

    Directory of Open Access Journals (Sweden)

    Jelle Van Loon

    2018-03-01

    Full Text Available Precision agriculture technology at the hands of smallholder farmers in the developing world is often deemed far-fetched. Low-resource farmers, however, are the most susceptible to negative changes in the environment. Providing these farmers with the right tools to mitigate adversity and to gain greater control of the production process could unlock their potential and support rural communities to meet the increasing global food demand. In this study, a real-time variable rate fertilizer application system was developed and tested as an add-on kit to conventional farm machinery. In the context of low investment costs for smallholder farmers, high user-friendliness and easy installment were the main concerns for the system to be viable. The system used nitrogen (N-sensors to assess the plant nutrient status on the spot and subsequently adjust the amount of fertilizer deposited according to the plant’s needs. Test bench trials showed that the add-on kit performed well with basic operations, but more precision is required. Variability between N-sensors and metering systems, combined with power fluctuations, created inaccuracies in the resulting application rate. Nevertheless, this work is a stepping stone towards catalyzing the elaboration of more cutting-edge precision solutions to support small-scale farmers to become successful, high producing agro-entrepreneurs.

  7. Gyrotron development at KIT: FULGOR test facility and gyrotron concepts for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, M., E-mail: martin.schmid@kit.edu [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Franck, J.; Kalaria, P.; Avramidis, K.A.; Gantenbein, G.; Illy, S. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Jelonnek, J. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Institute of High Frequency Techniques and Electronics (IHE), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Pagonakis, I. Gr.; Rzesnicki, T. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Thumm, M. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Institute of High Frequency Techniques and Electronics (IHE), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany)

    2015-10-15

    Highlights: • Substantial extension of the KIT gyrotron test facility FULGOR has started. • FULGOR will be able to test gyrotrons with continuous RF output power up to 4 MW. • Design of 240 GHz gyrotrons for efficient electron cyclotron current drive is progressing. • Output power of 240 GHz gyrotrons with conventional cavity up to 830 kW, with coaxial cavity up to 2 MW is feasible. • Multi-frequency operation with gyrotrons is also possible (170–267 GHz). - Abstract: At the Karlsruhe Institute of Technology (KIT), theoretical and experimental foundations for the development of future gyrotrons for fusion applications are being laid down. This includes the construction of the new Fusion Long Pulse Gyrotron Laboratory (FULGOR) test facility as well as physical design studies towards DEMO-compatible gyrotrons. Initially FULGOR will comprise of a 10 MW CW power supply, a 5 MW water cooling system (upgradeable to 10 MW), a superconducting 10 T magnet, one or two 2 MW ECRH test loads and a new control and data acquisition system for all these elements. The test facility will then be equipped to test the conventional 1 MW or coaxial 2 MW gyrotrons for DEMO, currently under design, as well as possible upgraded gyrotrons for W7-X and ITER. The design of the new high voltage DC power supply (HVDCPS) is flexible enough to handle gyrotrons with 4 MW CW output power (conceivably up to 170 GHz), but also test gyrotrons with higher frequencies (>250 GHz) which, due to physical limitations in the gyrotron design, will require less power but have more stringent demands on voltage stability.

  8. [4-t-butylphenyl]-N-(4-imidazol-1-yl phenyl)sulfonamide (ISCK03) inhibits SCF/c-kit signaling in 501mel human melanoma cells and abolishes melanin production in mice and brownish guinea pigs.

    Science.gov (United States)

    Na, Yong Joo; Baek, Heung Su; Ahn, Soo Mi; Shin, Hyun Jung; Chang, Ih-Seop; Hwang, Jae Sung

    2007-09-01

    It is well known that c-kit is related to pigmentation as well as to the oncology target protein. The objective of this study was to discover a skin-whitening agent that regulates c-kit activity. We have developed a high-throughput screening system using recombinant human c-kit protein. Approximately 10,000 synthetic compounds were screened for their effect on c-kit activity. Phenyl-imidazole sulfonamide derivatives showed inhibitory activity on c-kit phosphorylation in vitro. The effects of one derivative, [4-t-butylphenyl]-N-(4-imidazol-1-yl phenyl)sulfonamide (ISCK03), on stem-cell factor (SCF)/c-kit cellular signaling in 501mel human melanoma cells were examined further. Pretreatment of 501mel cells with ISCK03 inhibited SCF-induced c-kit phosphorylation dose dependently. ISCK03 also inhibited p44/42 ERK mitogen-activated protein kinase (MAPK) phosphorylation, which is known to be involved in SCF/c-kit downstream signaling. However ISCK03 did not inhibit hepatocyte growth factor (HGF)-induced phosphorylation of p44/42 ERK proteins. To determine the in vivo potency of ISCK03, it was orally administered to depilated C57BL/6 mice. Interestingly, oral administration of ISCK03 induced the dose-dependent depigmentation of newly regrown hair, and this was reversed with cessation of ISCK03 treatment. Finally, to investigate whether the inhibitory effect of ISCK03 on SCF/c-kit signaling abolished UV-induced pigmentation, ISCK03 was applied to UV-induced pigmented spots on brownish guinea pig skin. The topical application of ISCK03 promoted the depigmentation of UV-induced hyperpigmented spots. Fontana-Masson staining analysis showed epidermal melanin was diminished in spots treated with ISCK03. These results indicate that phenyl-imidazole sulfonamide derivatives are potent c-kit inhibitors and might be used as skin-whitening agents.

  9. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease.

    Science.gov (United States)

    Nagarale, Girish; Ravindra, S; Thakur, Srinath; Setty, Swati

    2010-10-01

    C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis.

  10. Long-lived immunity to canine core vaccine antigens in UK dogs as assessed by an in-practice test kit.

    Science.gov (United States)

    Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J

    2018-01-01

    To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.

  11. [Clinical evaluation of triage as drug-of-abuse test kit].

    Science.gov (United States)

    Yoshioka, Toshiharu; Kohriyama, Kazuaki; Kondo, Rumiko; Goto, Kyoko; Yashiki, Mikio

    2003-01-01

    There are about 60,000 chemical substances which may cause poisoning. Identifying the cause substances is, therefore, very important for patient at emergency department. Triage is an immunoassay kit for the qualitative test for the metabolites of 8 major abuse drugs in urine. We assessed the usefullness of Triage on two patient groups. The first Group consists of the patients considered having not taken substances at initial diagnosis; the second Group consists of the patients considered having taken substances. The result are as follows. 1) The rate of Triage positive patients in the first Group were: attempt-suicide 23%, coma 24%, shock 10%, trauma 7%, respectively. Except for the habitually used medicine, narcotic and stimulant drugs were detected. In the first Group, negative result of Triage was effective in diagnosing the patients as not poisoned, excluding the possitivity of 8 major drugs usage. 2) The rate of Triage positive patients in the second Group were very high: attempt-suicide 77%, coma 51%, shock 57%, trauma 30%, respectively, showing mostly any of 8 major drugs were the cause of poisoning. In the second Group, positive result of Triage was effective in diagnosing the patient as poisoning or as coexisting poisoning with other diseases. 3) The specificity of Triage diagnosis in the first Group was 80% (113/142). The specificity and the sensitivity in the second Group were 64% (50/78) and 97% (74/76), respectively. These results means that Triage is very useful for diagnosis on 8 major drugs poisoning. 4) Triage is efficient for identifying the cause substances in drug poisoning and, therefore, can save medical expense. Triage is a very useful test kit at emergency department.

  12. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  13. Quality and use of consumer information provided with home test kits: room for improvement.

    Science.gov (United States)

    Grispen, Janaica E J; Ickenroth, Martine H P; de Vries, Nanne K; van der Weijden, Trudy; Ronda, Gaby

    2014-10-01

    Diagnostic self-tests (tests on body materials that are initiated by consumers with the aim of diagnosing a disorder or risk factor) are becoming increasingly available. Although the pros and cons of self-testing are currently not clear, it is an existing phenomenon that is likely to gain further popularity. To examine consumers' use of and needs for information about self-testing, and to assess the quality of consumer information provided with home test kits, as perceived by consumers and as assessed using a checklist of quality criteria. A cross-sectional Internet survey among 305 self-testers assessed their use of and needs for information and their perception of the quality of consumer information provided with self-test kits. A meta-search engine was used to identify Dutch and English consumer information for home diagnostic tests available online at the time of the study. The quality of this consumer information was evaluated using a checklist of quality criteria. The consumers' information needs were in line with the most frequently used information, and the information was perceived as being of moderate to good quality. The information was mostly in agreement with clinical practice guidelines, although information on reliability and follow-up behaviour was limited. Approximately half of the instruction leaflets did not include information on the target group of the test. Although generally of moderate to good quality, some aspects of the information provided were in many cases insufficient. European legislation concerning self-tests and accompanying information needs to be adapted and adhered to more closely. © 2012 John Wiley & Sons Ltd.

  14. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    Science.gov (United States)

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  15. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  16. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  17. Sensitivity and specificity of the nickel spot (dimethylglyoxime) test

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Skare, Lizbet; Lundgren, Lennart

    2010-01-01

    The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate nickel release around...... the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test....

  18. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases.

    Science.gov (United States)

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-10-01

    The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis.

  19. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases

    Science.gov (United States)

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-01-01

    Objective: The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Materials and Methods: Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. Results: The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. Conclusion: The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis. PMID:29123441

  20. Comparação de kits ELISA® comerciais para anticorpos no soro e leite com um teste coproparasitológico em bovinos naturalmente infectados por Fasciola hepatica Comparison of comercial® ELISA kits for antibodies in serum and milk with a fecal test in cattle naturally infected with Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Cíntia das C. Bernardo

    2013-01-01

    Full Text Available A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92 sangue (92 e leite (43 de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (pThe fascioliasis is a disease caused by a trematode that affects the liver mainly of domestic ruminants and can also parasite man; its diagnosis is routinely done by coprological methods. The aim of this study was to compare commercial ELISA kits for antibodies in serum and milk with a coprological test in cattle naturally infected by Fasciola hepatica. We collected fecal, blood and milk samples from cattle in the municipality of Jerônimo Monteiro, southern Espírito Santo state. The fecal samples were processed by the fecal egg sedimentation for F. hepatica, which is used as a gold standard for analyzis. Blood (92 and milk (43 samples were processed according to the manufacturer instructions of the respective commercial ELISA kits tested. We used the McNemar chi-square for

  1. Estradiol RIA kit in clinical practice

    International Nuclear Information System (INIS)

    Friedrich, W.; Lisse, K.; Bienert, R.; Flentje, H.; Koerner, H.; Wilken, T.; Akademie der Wissenschaften der DDR, Berlin-Buch. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1985-01-01

    First clinical experience with a estradiol RIA kit developed in the Central Institute for Isotope- and Radiation Research is reported. The kit was used for the daily control of estradiol level in patients, which were treated within the program for in vitro fertilization and embryo transfer. The time of incubation could be shortened by means of a double antibody technique and by use of a precipitation mixture to 2 h. The intraassay variation is 9.2%, the interassay variation is 15.1%, the recovery rate is 94%. The sensitivity of the test (B 0 -3SD) is about 120 pmol/l. The estradiol RIA kit satisfies clinical requirements. (author)

  2. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  3. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  4. Screening of antibiotics residues and development a new kit

    International Nuclear Information System (INIS)

    Elkhaoui, Faycel

    2009-01-01

    The first part of the work was to detect antibiotic residues in animal nutriment: chicken, fish, eggs and milk, by methods of screening: First Test and Delvotest. The second part covered the development of a new kit for the detection of antibiotics residues for honey and competitor kit First Test and saving time and money.

  5. Validity of urinary monoamine assay sales under the "spot baseline urinary neurotransmitter testing marketing model".

    Science.gov (United States)

    Hinz, Marty; Stein, Alvin; Uncini, Thomas

    2011-01-01

    Spot baseline urinary monoamine assays have been used in medicine for over 50 years as a screening test for monoamine-secreting tumors, such as pheochromocytoma and carcinoid syndrome. In these disease states, when the result of a spot baseline monoamine assay is above the specific value set by the laboratory, it is an indication to obtain a 24-hour urine sample to make a definitive diagnosis. There are no defined applications where spot baseline urinary monoamine assays can be used to diagnose disease or other states directly. No peer-reviewed published original research exists which demonstrates that these assays are valid in the treatment of individual patients in the clinical setting. Since 2001, urinary monoamine assay sales have been promoted for numerous applications under the "spot baseline urinary neurotransmitter testing marketing model". There is no published peer-reviewed original research that defines the scientific foundation upon which the claims for these assays are made. On the contrary, several articles have been published that discredit various aspects of the model. To fill the void, this manuscript is a comprehensive review of the scientific foundation and claims put forth by laboratories selling urinary monoamine assays under the spot baseline urinary neurotransmitter testing marketing model.

  6. Development of RIA kits for tumor-markers monitoring

    International Nuclear Information System (INIS)

    Suprarop, P.

    1997-01-01

    All reagents for tumor markers assays are imported from various manufacturers mainly CIS bio international. The average cost of these reagents is ranged from 80-150 bath/test (2-4 dollars test). The screening test for cancers could not be done especially in other regions of Thailand whose budgets and resources are so limited. If the reagents are made locally, many laboratories can perform the tests and use as primary diagnosis, screening or monitor the course of the disease following treatment. In addition, these reagents could help clinicians and give complementary information on the tumor status to improve quality of life in Thailand. Research objectives include: 1. Development of IRMA reagent kits suitable for diagnosing staging and monitoring prostrate and breast cancer. 2. Transfer of technology and reagent kits to relevant laboratories in Thailand. 3. Routine distribution of the reagents kits to the end users

  7. Determination of triiodothyronine using RIA-Mat T3 kit

    International Nuclear Information System (INIS)

    Hara, Masao

    1975-01-01

    A RIA-Mat T 3 kit was used for an in vitro measurement of triiodothyronine in serum. A resin strip was utilized to absorb free triiodothyronine after the serum was incubated with antibody against triiodothyronine. This test was easy to manipulate and the reproducibility test with same sera, dilution test, and recovery test were also satisfactory. The normal range of triiodothyronine determined with this test kit was 119 +- 40 ng/dl using 50 test sera. Ninety sera with various thyroid diseases were also determined. (auth.)

  8. Personal Computer-less (PC-less) Microcontroller Training Kit

    Science.gov (United States)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  9. '. . . if you bring the kit home, you [can] get time and test together with your partner': Pregnant women and male partners' perceptions regarding female partner-delivered HIV self-testing in Uganda - A qualitative study.

    Science.gov (United States)

    Matovu, Joseph Kb; Buregyeya, Esther; Arinaitwe, Jim; Wanyenze, Rhoda K

    2017-11-01

    In 2015, the World Health Organization reported that more than 60 million people were tested for HIV in 122 low- and middle-income countries between 2010 and 2014. Despite this level of progress, over 40% of people living with HIV remain unaware of their HIV status. This calls for innovative approaches to improve uptake of HIV testing services, including use of HIV self-test (HIVST) kits. We conducted a cross-sectional, qualitative study to assess pregnant women and their male partners' perceptions regarding female partner-delivered HIVST kits. This study was conducted at two health facilities in Central Uganda between November and December 2015. Data were collected on pregnant women's willingness to take HIVST kits to their male partners and other household members using eight focus group discussions and 30 in-depth interviews. Data were analyzed following a thematic framework approach. Overall, pregnant women were willing to take HIVST kits to their partners and other household members, with the exception of their cowives. Male partners were willing to use HIVST kits brought by their female partners. Our findings suggest that secondary distribution of HIVST kits through female partners is acceptable and has the potential to improve male partner and household-member HIV testing.

  10. Production of sestamibi kit for nuclear imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Hakim; Zakaria, Ahmad; Yaacob, Hadzri; Ramli, Jamaluddin [Universiti Sains Malaysia, Kelantan (Malaysia). School of Medical Sciences

    1997-12-01

    One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci per 20 gm body weight. The mice were sacrificed at 3 hours and 24 hours after the dose administration. Blood, heart, lung, intestine, kidney and stomach samples were obtained, weighed and measured for radioactivity using gamma well counter. The data showed that after 3 hours about 60% of the injected dose accumulated in the intestine which was in agreement with IAEA standard. At 24 hours the amount in the heart still remained about 25% of the 3 hour uptake. In house production of MIBI kit is easy, fast and cost effective. The data suggested that the quality of our kit was good enough to be used for further animal research and clinical trials.

  11. Testing a class of non-Kerr metrics with hot spots orbiting SgrA*

    International Nuclear Information System (INIS)

    Liu, Dan; Li, Zilong; Bambi, Cosimo

    2015-01-01

    SgrA*, the supermassive black hole candidate at the Galactic Center, exhibits flares in the X-ray, NIR, and sub-mm bands that may be interpreted within a hot spot model. Light curves and images of hot spots orbiting a black hole are affected by a number of special and general relativistic effects, and they can be potentially used to check whether the object is a Kerr black hole of general relativity. However, in a previous study we have shown that the relativistic features are usually subdominant with respect to the background noise and the model-dependent properties of the hot spot, and eventually it is at most possible to estimate the frequency of the innermost stable circular orbit. In this case, tests of the Kerr metric are only possible in combination with other measurements. In the present work, we consider a class of non-Kerr spacetimes in which the hot spot orbit may be outside the equatorial plane. These metrics are difficult to constrain from the study of accretion disks and indeed current X-ray observations of stellar-mass and supermassive black hole candidates cannot put interesting bounds. Here we show that near future observations of SgrA* may do it. If the hot spot is sufficiently close to the massive object, the image affected by Doppler blueshift is brighter than the other one and this provides a specific observational signature in the hot spot's centroid track. We conclude that accurate astrometric observations of SgrA* with an instrument like GRAVITY should be able to test this class of metrics, except in the more unlikely case of a small viewing angle

  12. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit.

    Science.gov (United States)

    Marsan, David W; Conrad, Stephen M; Stutts, Whitney L; Parker, Christine H; Deeds, Jonathan R

    2018-03-01

    The cyanobacterium Aphanizomenon flos-aquae (AFA), from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA) dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC) for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP) regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1) identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2) use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA), based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51) distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit), 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1-2.8 μg/g). LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  13. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit

    Directory of Open Access Journals (Sweden)

    David W. Marsan

    2018-03-01

    Full Text Available The cyanobacterium Aphanizomenon flos-aquae (AFA, from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1 identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2 use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA, based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51 distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit, 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1–2.8 μg/g. LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  14. Testing the Efficiency of the Foreign Exchange Spot Market in Iran

    OpenAIRE

    Borhan-Azad, Lida

    2006-01-01

    This dissertation aimed at testing the efficiency of the foreign exchange market of Iran in the weak and semi-strong form using data on the black market spot exchange rates between Iranian currency (i.e., Rial) and four major foreign currencies including US Dollar, German Mark/Euro, UK Pound and Japanese Yen. The weak form efficiency is examined by unit root tests including Augmented Dickey-Fuller (1979, 1981) (ADF) test and Phillips-Perron (1988) (PP) test. The results of these tests are con...

  15. Dumpster Optics: teaching and learning optics without a kit

    Science.gov (United States)

    Donnelly, Judy; Magnani, Nancy; Robinson, Kathleen

    2016-09-01

    The Next Generation Science Standards (NGSS) and renewed emphasis on STEM education in the U.S. have resulted in the development of many educational kits for teaching science in general and optics in particular. Many teachers do not have funding to purchase kits and practical experience has shown that even costly kits can have poorly written and misleading instructions and may include experiments that would not work in a classroom. Dumpster Optics lessons are designed to use inexpensive, commonly found materials. All lessons have been field-tested with students. We will describe the development of the lessons, provide examples of field testing experiences and outline possible future activities.

  16. Laser Spot Center Detection and Comparison Test

    Science.gov (United States)

    Zhu, Jun; Xu, Zhengjie; Fu, Deli; Hu, Cong

    2018-04-01

    High efficiency and precision of the pot center detection are the foundations of avionics instrument navigation and optics measurement basis for many applications. It has noticeable impact on overall system performance. Among them, laser spot detection is very important in the optical measurement technology. In order to improve the low accuracy of the spot center position, the algorithm is improved on the basis of the circle fitting. The pretreatment is used by circle fitting, and the improved adaptive denoising filter for TV repair technology can effectively improves the accuracy of the spot center position. At the same time, the pretreatment and de-noising can effectively reduce the influence of Gaussian white noise, which enhances the anti-jamming capability.

  17. Discrepancies in Weil-Felix and microimmunofluorescence test results for Rocky Mountain spotted fever.

    Science.gov (United States)

    Hechemy, K E; Stevens, R W; Sasowski, S; Michaelson, E E; Casper, E A; Philip, R N

    1979-01-01

    Only 4.2% of 284 single specimens and 17.6% of 51 pairs of sera reactive in Weil-Felix agglutination tests for Rocky Mountain spotted fever were confirmed by a specific Rickettsia rickettsii microimmunofluorescence test. PMID:107194

  18. A 'same day' TSH radioimmunoassay kit with acceptable precision and accuracy

    International Nuclear Information System (INIS)

    Wood, W.G.; Muenchen Univ.

    1980-01-01

    A new 'same-day' TSH-RIA kit has been tested against an 'in-house' TSH-RIA, using incubation schemes of 4, 22 and 23 h. The kit standards were made up in human TSH-free serum and the method used a preincubation step and separation of bound and free antigen using a double antibody method. The correlation between the 'in-house' method and the kit was very good. The results in sera from TRH-test patients, and also from a recovery test with MRC 68/38 in human serum covering the range 0-50 mU/l were good. A comparison of the new kit was made with its precedessor which had protein based standards highlighted the need for standards in human TSH-free serum seen by the poor correlation (r = 0.619, n = 93). (orig.) [de

  19. Monitoring of cyclosporine concentrations by using dry blood-spot samples.

    Science.gov (United States)

    Mee, A V; Wong, P Y; Sun, C; Oei, L; Elliott, S; Naik, N; Joaquin, B; Uchimaru, D

    1991-01-01

    We modified the Incstar Cyclo Trac SP kit to enable its use with dry blood-spots on filter paper. The recovery ranged from 92 to 106%. Dilution studies have shown excellent linearity and parallelism throughout the range of the assay. Precision is demonstrated by within-assay CV's of 6.6 and 4.3% at 96 and 342 micrograms/L respectively and between-assay CV's of 9.1 and 7.0% at 138 and 506 micrograms/L respectively. A comparison study (n = 209) with whole blood assay gave a correlation coefficient of 0.97, a slope of 1.04, and an intercept of 13.2. Whole blood and dry blood-spot cyclosporine assays on heart, kidney, liver, and lung transplants were also compared.

  20. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    Science.gov (United States)

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  1. KIT safety management. Annual report 2013; KIT-Sicherheitsmanagement. Jahresbericht 2013

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Gerhard (ed.)

    2014-07-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for licensing procedures, industrial safety organization, control of environmental protection measures, planning and implementation of emergency preparedness and response, operation of radiological laboratories and measurement stations, extensive radiation protection support and the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2013. Status figures in principle reflect the status at the end of the year 2013. The processes described cover the areas of competence of KSM. Due to changes in the organization of the infrastructural service units in KIT, KSM has been cancelled at the end of 2013. Its tasks will mainly be covered in 2014 by the new founded service unit Safety and Environmental (Sicherheit und Umwelt, SUM). The departments Campus Security, Fire Brigade and Information Technology have been transferred to the Service Unit General Services (Allgemeine Services, ASERV).

  2. A comparative study in three commercial kits of radioligand assay for GAD-Ab

    International Nuclear Information System (INIS)

    Yang Yehua; Zhou Zhiguang; Huang Gan; Yang Feike; Li Zhangwei

    2006-01-01

    Objective: To provide data for perfect selection of glutamic acid decarboxylase antibodies (GAD-Ab) assay commercial kits. Methods: The sera of 88 titer-graded samples by radioligand assay (RLA) were measured with two types of enzyme-linked immunosorbent assay (ELISA) kits and one type of immunoradiometric assay (IRMA) kit for GAD-Ab in order to test their consistency with RLA. Another 140 diabetic sera were measured with RLA and screened by a type of suitable kit to search the cutoff point for discriminating patients who needed rechecking. Results: Compared with RLA, concordance ratio of 3 kits: Medizym kit(75%) > RSR kit(73.9%) > Biomerica kit(62.5%); Kappa value: Medizym kit (0.408, common) > RSR kit (0.405, common) > Biomerica kit (0.185, failing); correlation to RLA index: RSR kit (r= 0.992) > Medizym kit(r= 0. 791 ) > Biomerica kit (r = -0. 055); area under the receiver operating characteristic (ROC) curve: Medizym kit (0.812) > RSR kit (0. 727 ) > Biomerica kit (0.666). Conclusions: The efficiencies of RSR kit and Medizym kit are good. Serum concentration between 0.25-0.99 U/ml measured by RSR kit is suggested to further recheck by RLA. (authors)

  3. 40 CFR 86.163-00 - Spot check correlation procedures for vehicles tested using a simulation of the environmental...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Spot check correlation procedures for... Complete Heavy-Duty Vehicles; Test Procedures § 86.163-00 Spot check correlation procedures for vehicles... running change approval, each model year for any manufacturer undergoing the spot checking procedures of...

  4. KIT safety management. Annual report 2012; KIT-Sicherheitsmanagement. Jahresbericht 2012

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Gerhard (ed.)

    2013-07-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for - licensing procedures, - industrial safety organization, - control of environmental protection measures, - planning and implementation of emergency preparedness and response, - operation of radiological laboratories and measurement stations, - extensive radiation protection support and the - the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its industrial safety management is certified by the VBG as ''AMS-Arbeitsschutz mit System'' and, hence, fulfills the requirements of NLF / ISO-OSH 2001. KSM laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2012. Status figures in principle reflect the status at the end of the year 2012. The processes described cover the areas of competence of KSM.

  5. Diagnosis of Latent Tuberculosis in Patients with Systemic Lupus Erythematosus: T.SPOT.TB versus Tuberculin Skin Test

    Directory of Open Access Journals (Sweden)

    Maria Del Mar Arenas Miras

    2014-01-01

    Full Text Available Early studies in patients with systemic lupus erythematosus (SLE reported increased incidence of tuberculosis. The tuberculin skin test (TST is the technique of choice to detect latent tuberculosis infection (LTBI but has several limitations. Objectives. We compared TST and the newer T.SPOT.TB test to diagnose LTBI in SLE patients. Methods. In this observational cohort study conducted between August 2009 and February 2012, we recruited 92 patients from those attending the SLE clinic of our university hospital. Data recorded were epidemiological and sociodemographic characteristics. Laboratory analyses included TST and T.SPOT.TB tests. Results. Of the patients studied, 92% were women with an average age of 42.7 years. Overall, the degree of correlation between the two tests was low (Kappa index = 0.324 but was better in patients not receiving corticosteroids (CTC/immunosuppressive (IS therapy (Kappa = 0.436 and in those receiving hydroxychloroquine (Kappa = 0.473. While TST results were adversely affected by those receiving CTC and/or IS drugs (P=0.021, the T.SPOT.TB results were not. Conclusion. Although the TST test remains a useful tool for diagnosing LTBI in SLE patients, the T.SPOT.TB test is perhaps better employed when the patient is receiving CTC and/or IS drugs.

  6. Prolonged expression of the c-kit receptor in germ cells of intersex fetal testes

    DEFF Research Database (Denmark)

    Rajpert-De Meyts, Ewa; Jørgensen, N; Müller, Jørn

    1996-01-01

    conditions which included 45,X/46,XY mosaicism; androgen insensitivity syndrome; and 46,XY/iso(p)Y mosaicism. Individuals with such disorders of sexual differentiation and Y-chromosome material carry a very high risk of developing testicular neoplasms. Fetal testicular germ cells of the intersex subjects...... expressed Kit at a later developmental age than controls, in which no Kit protein was detectable beyond the 15th week of gestation. This finding may indicate a disturbance of the chronology of germ cell development, or it may suggest a change of the regulation of c-kit expression in subjects with disorders...

  7. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  8. Design of test kits for the RF characterization of the PAM antenna of LHCD system for Aditya-upgrade Tokamak

    International Nuclear Information System (INIS)

    Jain, Yogesh M.; Sharma, P.K.; Parmar, P.R.; Ambulkar, K.K.

    2017-01-01

    The Lower Hybrid Current Drive (LHCD) system of the ADITYA-Upgrade tokamak will employ a Passive Active Multijunction (PAM) antenna to launch 250 kW of RF power at 3.7 GHz to drive plasma current non inductively in the tokamak. To evaluate the RF performance of the designed PAM antenna, it is characterized with the help of VNA measurements. The performance of the PAM antenna is mainly decided by the integrated performance of the entire antenna (with a differential phase shift of 270° and equal power distribution between each of the output waveguides) and the performance of mode converter, which transforms input TE 10 mode to TE 30 mode (with a mode purity of 98.5% at the output). This poster thus reports the design and analysis of these testing kits. Also, the test results of PAM antenna obtained by using these test kits would also be presented and discussed in this poster

  9. Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.

    Science.gov (United States)

    Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne

    2014-08-01

    To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.

  10. {sup 14}C urea breath test kit- an evaluation of a compact, cost-effective kit for the detection of H. pylori

    Energy Technology Data Exchange (ETDEWEB)

    Bellon, M.S. [Royal Adelaide Hospital, SA (Australia). Dept of Nuclear Medicine

    1998-03-01

    Full text: Helicobacter pylori infection of the gastric mucosa causes active chronic gastritis and peptic ulceration. Carbon-14 urea breath testing has been well documented in its ability to detect the presence of H. pylori. The aims of this study were to evaluate and refine the test to substantially reduce costs and improve its simplicity, availability and accuracy. We reviewed the results of 138 patients who underwent {sup 14}C urea breath testing for the detection of H. pylori utilising a kit developed at the Royal Adelaide Hospital. Modifications to the standard technique that were assessed included the relevance of buccal cleansing, single sample v multiple sampling, use of alternative CO{sub 2} absorbers and sampling techniques. In those patients with positive biopsy results, a test sensitivity of 100% was achieved. No buccal cleansing is necessary (45% oral contamination without brushing teeth v 41% with). A single breath sample only at 15 min resulted in 100% sensitivity. Alternative (cheaper and safer) CO{sub 2} absorbers such as KOH can be used. Based on these results, modifications to this well documented test have enabled us to substantially reduce costs, improve simplicity and safety and increase accuracy and availability of the test for the detection of Helicobacter pylori.

  11. IODOBELL in vivo kits for in situ labelling with iodine

    International Nuclear Information System (INIS)

    Koernyei, Jozsef; Lakatos, Mihaly; Kecskes, Ferenc; Mahunka, Imre; Mikecz, Pal; Ando, Laszlo

    1988-01-01

    A system of in vivo kits called IODOBELL was developed in the Institute of Isotopes, Budapest. The production of hepatodecanoic acid for cardiology, iodo-hippuranic acid for kidney diagnostics and a special pharmaceutical, IODOBELL-MIGB for the indication of feochromocitoma and neuroblastoma is reported. The heptadecanoic acid kit is under human examination, the other two are to be tested in the near future. IODOBELL kits contribute to the wider use of 123 I in Hungary. (author) 6 refs

  12. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    Science.gov (United States)

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  13. Usefulness of CA 130 kit based on IRMA

    International Nuclear Information System (INIS)

    Fujii, Takashi; Kimura, Yoshiko; Ata, Mariko; Miyagawa, Naoko; Iio, Atsushi; Hamamoto, Ken

    1988-01-01

    Immunoradiometric assay for CA 130 was fundamentally and clinically evaluated using a commercially available D-7111 kit. Incubation time was 4 hr with the present CA 133 kit as compared with 16 - 24 hr with conventional CA 125 kit. Laboratory performance of CA 130 kit was satisfactory for standard curve, reproducibility, and recovery test. There was well correlation between the present CA 130 kit and CA 125 kit (r = 0.931). The concentration of CA 130 in the serum was significantly higher in healthy women than men (17.3 +- 10.5 U/ml vs 9.6 +- 5.1 U/ml). Serum CA 130 levels tended to decrease with aging, regardless of sex. These levels were changeable with menstrual cycle ; i.e., these were significantly higher during menstrual phase (24.2 +- 9.0 U/ml) and significantly lower during ovulatory phase (10.9 +- 2.4 U/ml) and during menopause (12.1 +- 3.4 U/ml). Cut off serum CA 130 levels were defined as 20 U/ml for men and 38 U/ml for women. Positive rate for CA 130 was the highest in cases of ovarian cancer (80 %), followed by endometrial cancer (50 %), pancreatic cancer (47 %), benign ovarian tumor (44 %), and lung cancer (39 %). (Namekawa, K.)

  14. New RIA kit for determination of progesterone in cow milk

    International Nuclear Information System (INIS)

    Byszewska-Szpocinska, E.; Markiewicz, A.

    2006-01-01

    The determination of progesterone concentration in whole and fat-free milk 19-24 days after conception enables to distinguish fertile and non-fertile insemination, which is important in cattle breeding. The aim of this work was to develop a simple and quick radioimmunoassay test for the determination of progesterone in cow milk. Two types of solid-phase tubes coated with specific polyclonal anti-progesterone antibody from ORION Diagnostica and BIOSOURCE International, two different progesterone derivatives viz. progesterone-3- carboxymethyl oxime (CMO) and progesterone-11α-hemisuccinate (HS) conjugated to 125 I-histamine and the HPLC system with Lichrospher RP-18 column along with 65% acetonitrile/water as eluent to purify the tracers were used to carry out this work. Progesterone-3CMO- 125 I-histamine had a retention time of 13.2 min and progesterone-11α-hemisuccinate- 125 I-histamine had a retention time of 7.8 min. Two kinds of kits (kit I and kit II) were prepared, first with progesterone-3CMO- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit of ORION Diagnostica and the second with progesterone-11αHS- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit from BIOSOURCE International. Progesterone from Sigma and selected fat-free cow's milk without progesterone as zero progesterone milk matrix were used for standard preparation. The optimal assay procedure was as follows: 50μL standards, controls and fat-free milk samples were pipetted into coated tubes followed by addition of 500μL of diluted tracer. The tubes were incubated for 2h in case of kit I and 3h for kit II at RT. After the incubation, the tubes were decanted and counted. The assay range was 0 to 270 nmol/L for kit I and 0 to 300 nmol/L for kit II. The sensitivity of the kit with ORION coated tubes was better (0.8 nmol/L) than that of BIOSOURCE tubes which was 1.5 nmol/L. Validation of these assays in terms of specificity, accuracy

  15. Assessing genotoxicity of diuron on Drosophila melanogaster by the wing-spot test and the wing imaginal disk comet assay.

    Science.gov (United States)

    Peraza-Vega, Ricardo I; Castañeda-Sortibrán, América N; Valverde, Mahara; Rojas, Emilio; Rodríguez-Arnaiz, Rosario

    2017-05-01

    The aim of this study was to evaluate the genotoxicity of the herbicide diuron in the wing-spot test and a novel wing imaginal disk comet assay in Drosophila melanogaster. The wing-spot test was performed with standard (ST) and high-bioactivation (HB) crosses after providing chronic 48 h treatment to third instar larvae. A positive dose-response effect was observed in both crosses, but statistically reduced spot frequencies were registered for the HB cross compared with the ST. This latter finding suggests that metabolism differences play an important role in the genotoxic effect of diuron. To verify diuron's ability to produce DNA damage, a wing imaginal disk comet assay was performed after providing 24 h diuron treatment to ST and HB third instar larvae. DNA damage induced by the herbicide had a significantly positive dose-response effect even at very low concentrations in both strains. However, as noted for the wing-spot test, a significant difference between strains was not observed that could be related to the duration of exposure between both assays. A positive correlation between the comet assay and the wing-spot test was found with regard to diuron genotoxicity.

  16. Dry Kit Development And Clinical Test Of 99mTc-L,L-ECD Radiopharmaceutical For Vrain Perfusion Imaging

    International Nuclear Information System (INIS)

    Kartini, Nani; Sofyan, Rohestri; Rukmini; Iswahyudi

    2000-01-01

    Technetium- 99m ethyl cysteinate dimer ( 99m Tc-L,L-ECD) has been synthesized and formulated based on ligand exchanged reaction with 99mTc-glucoheptonate. Considering the low stability of the dry kit produced, it was fairly necessary to develop the manufacture of L,L-ECD dry kit in order to obtain a more stable one that meet the requirements as brain perfusion imaging radiopharmaceutical. Experiment was done by modifying the packing of dry kit components of the previous formulation. Characteristics of 99m Tc-L,L-ECD produced from this formulation were studied by carrying out the sterility and toxicity test, then followed with clinical test to some volunteers. Evaluation of brain perfusion was done by tomography technique using gamma camera at Nuclear Medicine Installation, Hasan Sadikin Hospital. The modified formulation obtained consist of three components i.e. main ligand L,L-ECD; exchange ligand Ca-glucoheptonate and HaOH. Its stability could reach 8 months at-10 derajat C of storage. Effects of toxicity on mice did not appear. The result of clinical study shows that the radiopharmaceutical was distributed very rapidly in the blood brain circulations and retained in the brain for about one hour. The body scanning indicates that the substance was excreted in the brain for about one hour. The body scanning indicates that the substance was excreted though kidney, liver and spleen. Based on the results obtained the radiopharmaceutical could be promoted to be used for brain perfusion imaging

  17. Assessment of six commercial plasma small RNA isolation kits using qRT-PCR and electrophoretic separation

    DEFF Research Database (Denmark)

    Meerson, Ari; Ploug, Thorkil

    2016-01-01

    of specific miRNAs in different samples varied considerably between the tested extraction methods. Of all kits tested, the QIAGEN miRNeasy kits (Mini and Serum/Plasma kits) and the Macherey-Nagel NucleoSpin kit produced the highest RNA yields. The QIAGEN Exo kit produced lesser yields than what could...... be extracted from the UC fraction using the QIAGEN miRNeasy kits and the Macherey-Nagel NucleoSpin kit. Bioanalyzer results showed an average correlation of R2¼0.8 with endogenous miRNA qRT-PCR results, for sample concentrations >40 pg/ml. The levels of the endogenous miRNAs measured in the two volunteer...... samples were compared with those in a larger group of subjects (n¼10) and found to be typical. Our comparison favors the use of the QIAGEN Serum/Plasma kit and the Macherey-Nagel NucleoSpin kit for plasma miRNA applications. Furthermore, extraction of miRNAs from the UC fraction results in higher yield...

  18. The development of new diagnostic test-systems and improvement of the existed radio immunochemical kits in the industrial production conditions

    International Nuclear Information System (INIS)

    Abdukayumov, A.M.

    2002-04-01

    The highly effective method had been developed for HBsAg preparing and purification that allowed to use as the raw material a plasma of donors with low content of the target product and based on the application of the stepped fractionation by Ammonium Sulphate and affinity chromatography. The use efficiency of the produced HBsAg preparations had been shown for laboratory animals immunization with the purpose of antiserum production that was the intermediate product for component manufacture needed for high sensitive kit creation; for preparation of affinity immunosorbent with the purpose of highly specific anti-HBs preparing. The method had been developed for production of anti-HBs preparations with standard immunoreactivity from donkey serum by means of specific antibodies fractionation on affinity immunosorbent. The work was done to finish the method for 125 I incorporation into the monoclonal mouse antibody molecules resulting maximum high biological activity. It was determined that the highest quality provided by approach of the isotope introduction by means of Chloraimine T reagent. It had been developed and introduced into industrial production the modified highly sensitive kit 'IRMA-M-HBsAg- 125 I' for HBsAg detection in human blood serum with use of monoclonal antibodies with the help of which it was managed to increase the stability and sensitivity and to standardize the technology of the kit. The technology had been developed and completed the laboratory and clinical testing of the kits of reagents 'IRMA-M-HBsAg- 125 I', 'ELISA-HBsAg', 'Recombinant-anti-HCV-strip' that had shown the high specificity and reproduction of the analysis results. Immunoenzymetic kit 'ELISA-HBsAg' of the third generation for HBsAg detection in human blood serum with the sensitivity not less than 0.5 ng/ml was introduced into industrial production. It had been developed and introduced into industrial production the highly sensitive immunoenzymetic test-system 'Recombinant

  19. First aid kit

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001958.htm First aid kit To use the sharing features on this ... ahead, you can create a well-stocked home first aid kit. Keep all of your supplies in one ...

  20. Evaluation of serological tests for the diagnosis of rickettsiosis in Denmark

    DEFF Research Database (Denmark)

    Kantsø, Bjørn; Svendsen, Claus Bo; Jørgensen, Charlotte Svaerke

    2009-01-01

    Two commercially available immunofluorescence assays (IFA) were compared using historical sera evaluated for rickettsial antibodies by the Weil-Felix test. An IFA test produced by Focus Diagnostics prepared with Rickettsia rickettsii and R. typhi antigens was compared with a custom made kit from....... When analyzing the data using the manufacturers' cut-off values, 41% of samples from presumably healthy blood donors were found positive for spotted fever group Rickettsia antibodies. This does not correlate to the general picture of rickettsiosis in Denmark. Furthermore, sera with Coxiella burnetii...

  1. Tick testing as a method of controlling Rocky Mountain spotted fever.

    Science.gov (United States)

    Sacks, J J; Pinner, T A; Parker, R L

    1983-01-01

    In South Carolina, 1974-1980, only two matches were found between 536 Rocky Mountain spotted fever (RMSF) cases and 965 individuals who submitted ticks that tested rickettsial antigen positive. In neither case did the positive test prevent RMSF. Tick rickettsial positivity rates varied inversely with human RMSF attack rates in different geographic areas. A physician survey established it as unlikely that RMSF occurred in positive tick submitters (PTS), and that although not recommended, 34 per cent of asymptomatic PTS received prophylactic treatment. Only 18 per cent of positive ticks were engorged. Tick testing appears ineffective in preventing RMSF. PMID:6869643

  2. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    Science.gov (United States)

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  3. Spot weld arrangement effects on the fatigue behavior of multi-spot welded joints

    International Nuclear Information System (INIS)

    Hassanifard, Soran; Zehsaz, Mohammad; Esmaeili, Firooz

    2011-01-01

    In the present study, the effects of spot weld arrangements in multi-spot welded joints on the fatigue behavior of the joints are studied. Three different four-spot welded joints are considered: one-row four-spot parallel to the loading direction, one-row four-spot perpendicular to the loading direction and two-row four-spot weld specimens. The experimental fatigue test results reveal that the differences between the fatigue lives of three spot welded types in the low cycle regime are more considerable than those in the high cycle regime. However, all kinds of spot weld specimens have similar fatigue strength when approaching a million cycles. A non-linear finite element analysis is performed to obtain the relative stress gradients, effective distances and notch strength reduction factors based on the volumetric approach. The work here shows that the volumetric approach does a very good job in predicting the fatigue life of the multi-spot welded joints

  4. Analysis of KIT expression and KIT exon 11 mutations in canine oral malignant melanomas.

    Science.gov (United States)

    Murakami, A; Mori, T; Sakai, H; Murakami, M; Yanai, T; Hoshino, Y; Maruo, K

    2011-09-01

    KIT, a transmembrane receptor tyrosine kinase, is one of the specific targets for anti-cancer therapy. In humans, its expression and mutations have been identified in malignant melanomas and therapies using molecular-targeted agents have been promising in these tumours. As human malignant melanoma, canine malignant melanoma is a fatal disease with metastases and the poor response has been observed with all standard protocols. In our study, KIT expression and exon 11 mutations in dogs with histologically confirmed malignant oral melanomas were evaluated. Although 20 of 39 cases were positive for KIT protein, there was no significant difference between KIT expression and overall survival. Moreover, polymerase chain reaction amplification and sequencing of KIT exon 11 in 17 samples did not detect any mutations and proved disappointing. For several reasons, however, KIT expression and mutations of various exons including exon 11 should be investigated in more cases. © 2011 Blackwell Publishing Ltd.

  5. A new paradigm for Aedes spp. surveillance using gravid ovipositing sticky trap and NS1 antigen test kit.

    Science.gov (United States)

    Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra

    2017-03-21

    Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.

  6. Formulation of MIBI Kit as a heart imaging agent

    International Nuclear Information System (INIS)

    Widyastuti; A, Hanafiah; Yunilda; A, Laksmi; Setyowati, Sri; Y Veronika

    1999-01-01

    9 9 m Tc labelled 2-methoxy-isobutyl-isonitrile(MIBI) has been known as an imaging agent for myocardial perfusion. This radiopharmaceutical preparation gives the same satisfactory result as Thallium- 2 10TI, and presumably could replace 2 01TI because of same advantages. MIBI kit was formulated from MIBI ligand produced by RPC-BATAN which has been characterized and tested for quality. The formula used in this research referred to the formula of imported product(Cardiolite, MIBI kit produced by Dupont), and the quality control testing was performed by comparing some parameters to the imported product. The parameters used for QC testing were radiochemical purity, biodistribution in nice and heart imaging in human volunteer using gamma camera. The result of the experiment showed that the radiochemical purity was 95 % in average, biodistribution in heart to liver gave the ratio of 0.67, 1.5, and 2.53 respectively at 10, 30 and 60 minutes after injection. The result of clinical testing in some volunteers gave contrast images as good as given by Cardiolite. The optimum condition of freeze drying has been found, and the kit can be used for more than 6 months

  7. Inadequacy of IgM antibody tests for diagnosis of Rocky Mountain Spotted Fever.

    Science.gov (United States)

    McQuiston, Jennifer H; Wiedeman, Caleb; Singleton, Joseph; Carpenter, L Rand; McElroy, Kristina; Mosites, Emily; Chung, Ida; Kato, Cecilia; Morris, Kevin; Moncayo, Abelardo C; Porter, Susan; Dunn, John

    2014-10-01

    Among 13 suspected Rocky Mountain spotted fever (RMSF) cases identified through an enhanced surveillance program in Tennessee, antibodies to Rickettsia rickettsii were detected in 10 (77%) patients using a standard indirect immunofluorescent antibody (IFA) assay. Immunoglobulin M (IgM) antibodies were observed for 6 of 13 patients (46%) without a corresponding development of IgG, and for 3 of 10 patients (30%) at least 1 year post-onset. However, recent infection with a spotted fever group rickettsiae could not be confirmed for any patient, based on a lack of rising antibody titers in properly timed acute and convalescent serologic specimens, and negative findings by polymerase chain reaction testing. Case definitions used in national surveillance programs lack specificity and may capture cases that do not represent current rickettsial infections. Use of IgM antibodies should be reconsidered as a basis for diagnosis and public health reporting of RMSF and other spotted fever group rickettsiae in the United States. © The American Society of Tropical Medicine and Hygiene.

  8. Uji Stabilitas Kit Cair Tetrofosmin pada Berbagai Kondisi Penyimpanan

    Directory of Open Access Journals (Sweden)

    Yunilda Yunilda

    2016-09-01

    Full Text Available Tetrofosmin radiopharmaceutical compound that is being developed by PTRR BATAN for use as myocardial perfusion imaging agent and cancer diagnostic agent in nuclear medicine. The aim of this study is observe the stability of this liquid kits after stored in various condition to determine its expire date various condition. The stability test was done of 1 hour, 3 hours, 5 hours and 7 hours after labeling. The radiochemical was determined its radiochemical purity has to be ≥ 90 %. Analysis of radiochemical purity was carried out by separation method which using Sep-Pak C18 cartride. Storage condition of tetrofosmin kit was carried out at various temperatures as in the deep freezer (-800C, freezer (-180C, refrigerator (2-60C and cool box (2-60C. The result showed that the liquid tetrofosmin kits stored in deep freezer, freezer, refrigerator were stable up to 23 months, 8 weeks and 4 days respectively. Simulation of stability  test after stored in a cool box was done by observing the temperature of cool box, and the result showed that the temperature in the cool box was constant as in refrigerator for up to 24 hours. Tetrofosmin which has been labeled with technetium-99m can with stand up 7 hours. It is concluded that expiry date of liquid tetrofosmin kit related with storage temperature, the lower the temperature the longer the expiry date of the kits.

  9. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process

    Science.gov (United States)

    Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter

    2016-01-01

    Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263

  10. Assessment of chromium(VI) release from 848 jewellery items by use of a diphenylcarbazide spot test

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Hamann, Dathan

    2016-01-01

    We recently evaluated and validated a diphenylcarbazide(DPC)-based screening spot test that can detect the release of chromium(VI) ions (≥0.5 ppm) from various metallic items and leather goods (1). We then screened a selection of metal screws, leather shoes, and gloves, as well as 50 earrings......, and identified chromium(VI) release from one earring. In the present study, we used the DPC spot test to assess chromium(VI) release in a much larger sample of jewellery items (n=848), 160 (19%) of which had previously be shown to contain chromium when analysed with X-ray fluorescence spectroscopy (2)....

  11. Exploit Kit traffic analysis

    OpenAIRE

    Καπίρης, Σταμάτης; Kapiris, Stamatis

    2017-01-01

    Exploit kits have become one of the most widespread and destructive threat that Internet users face on a daily basis. Since the first actor, which has been categorized as exploit kit, namely MPack, appeared in 2006, we have seen a new era on exploit kit variants compromising popular websites, infecting hosts and delivering destructive malware, following an exponentially evolvement to date. With the growing threat landscape, large enterprises to domestic networks, have starte...

  12. Quality control of radioimmunoassay kits of pituitary hormones; Control de calidad de kits de radioinmunoanalisis de hormonas hipofisiarias

    Energy Technology Data Exchange (ETDEWEB)

    Caso Pena, R [Centro de Isotopos, La Habana (Cuba); Arranz Calzado, C [Instituto Nacional de Endocrinologia, La Habana (Cuba)

    1998-12-31

    The present work describe the quality control procedures carried out on three RIA-Kits by the Isotopes Centre of Cuba, The subject matter of study were ;: were: LH-RIA-Kit, FSH-RIA-Kit and Prolactin- RIA -Kit. The controls have included the characterization of the {sup 125}I labelled hormones the specific antibodies, the 2 nd antibodies, the standards curves and the control serum. For the validation of these Kits were used reference standards from the WHO (World Health Organizations) and Kits from CIS company (France) based on the IRMA assays technologies . The results obtained allow us encourage the reliability of RIA-Kits

  13. Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit

    Directory of Open Access Journals (Sweden)

    Mijin Kim

    2016-09-01

    Full Text Available BackgroundSecond-generation thyroglobulin immunometric assays (Tg-IMAs have been developed with improved sensitivity. Our aim was to compare the diagnostic value of Tg-IMA measurements using a Kryptor (BRAHMS AG kit (Tg-K and an ACCESS (Beckman Coulter kit (Tg-A with that of the first-generation Tg measurement using a Tg-plus (BRAHMS AG kit (Tg+.MethodsWe enrolled 82 differentiated thyroid cancer patients who underwent total thyroidectomy with radioactive iodine remnant ablation and who underwent diagnostic whole body scan using recombinant human thyroid stimulating hormone (rhTSH. The Tg+, Tg-K, and Tg-A were measured before rhTSH administration during levothyroxine treatment (suppressed Tg from the same sample. Serum Tg+ was measured after rhTSH stimulation (stimulated Tg.ResultsSuppressed Tg+ was more significantly correlated with suppressed Tg-K (R2=0.919, P<0.001 than with suppressed Tg-A (R2=0.536, P<0.001. The optimal cut-off values of suppressed Tg+, Tg-K, and Tg-A for predicting stimulated Tg+ of 1 ng/mL were 0.3, 0.2, and 0.2 ng/mL, respectively. The sensitivity, specificity, and accuracy of suppressed Tg+ were 67%, 100%, and 90%, respectively; those of suppressed Tg-K were 83%, 90%, and 88%; those of suppressed Tg-A were 96%, 82%, and 87%, respectively. The positive predictive and negative predictive values of Tg+ were 100% and 87%, respectively; those of Tg-K were 79% and 92%; and those of Tg-A were 73% and 98%.ConclusionWe could not clearly demonstrate which kit had better diagnostic performance after comparison of first-generation Tg measurements with Tg-IMA measurements. Also, there were kit-to-kit variations between Tg-IMA kits. Suppressed Tg measured by Tg-IMA was insufficient to completely substitute for a stimulated Tg measurement.

  14. Need for standardization of methodology and components in commercial radioimmunoassay kits

    Energy Technology Data Exchange (ETDEWEB)

    Wood, W G; Marschner, I; Scriba, P C [Muenchen Univ. (Germany, F.R.). Medizinische Klinik Innenstadt

    1977-01-01

    The problems arising from increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. The problems arising in various RIAs differ according to the substance under test. The quality of individual components is often good, although methodology is often not optimal and contains short-cuts, which although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modification of methodology often leads to major improvements in sensitivity and precision, and this has been demonstrated in the case of three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that in many imported quality control sera from the USA no values have been ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The deductions from this study are that a standardization of kit components and assay methods is desirable in order to allow comparison of results between laboratories using different kits.

  15. [CLINICAL UTILITY OF T-SPOT.TB ASSAY WITH T-Cell Xtend REAGENT FOR ACTIVE TUBERCULOSIS DIAGNOSIS IN THE FIELD TEST AT OUR HOSPITAL].

    Science.gov (United States)

    Nemoto, Kenji; Oh-ishi, Shuji; Taguchi, Masato; Hyodo, Kentaro; Kanazawa, Jun; Miura, Yukiko; Takaku, Takio; Usui, Shingo; Hayashihara, Kenji; Saito, Takefumi

    2016-04-01

    T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.

  16. Laser based spot weld characterization

    Science.gov (United States)

    Jonietz, Florian; Myrach, Philipp; Rethmeier, Michael; Suwala, Hubert; Ziegler, Mathias

    2016-02-01

    Spot welding is one of the most important joining technologies, especially in the automotive industry. Hitherto, the quality of spot welded joints is tested mainly by random destructive tests. A nondestructive testing technique offers the benefit of cost reduction of the testing procedure and optimization of the fabrication process, because every joint could be examined. This would lead to a reduced number of spot welded joints, as redundancies could be avoided. In the procedure described here, the spot welded joint between two zinc-coated steel sheets (HX340LAD+Z100MB or HC340LA+ZE 50/50) is heated optically on one side. Laser radiation and flash light are used as heat sources. The melted zone, the so called "weld nugget" provides the mechanical stability of the connection, but also constitutes a thermal bridge between the sheets. Due to the better thermal contact, the spot welded joint reveals a thermal behavior different from the surrounding material, where the heat transfer between the two sheets is much lower. The difference in the transient thermal behavior is measured with time resolved thermography. Hence, the size of the thermal contact between the two sheets is determined, which is directly correlated to the size of the weld nugget, indicating the quality of the spot weld. The method performs well in transmission with laser radiation and flash light. With laser radiation, it works even in reflection geometry, thus offering the possibility of testing with just one-sided accessibility. By using heating with collimated laser radiation, not only contact-free, but also remote testing is feasible. A further convenience compared to similar thermographic approaches is the applicability on bare steel sheets without any optical coating for emissivity correction. For this purpose, a proper way of emissivity correction was established.

  17. The need for standardization of methodology and components in commercial radioimmunoassay kits

    International Nuclear Information System (INIS)

    Wood, W.G.; Marschner, I.; Scriba, P.C.

    1978-01-01

    The problems arising from the increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. These problems differ according to the substance under test. The quality of individual reagents is often good, but the methodology is often not optimal and may contain short-cuts which, although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modifications in the methodology often lead to big improvements in sensitivity and precision. This has been demonstrated in three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that with many quality-control sera imported from the USA no values are ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The study underlines the need to standardize kit components and assay methods to enable the results obtained by different laboratories with different kits to be compared. (author)

  18. Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.

    Science.gov (United States)

    Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E

    2014-07-26

    Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.

  19. Increasing the flexibility of the LANCE cAMP detection kit.

    Science.gov (United States)

    Hunter, Morag Rose; Glass, Michelle

    2015-01-01

    The detection of cAMP signalling is a common endpoint in the study of G-protein coupled receptors. A number of commercially available kits enable easy detection of cAMP. These kits are based on competition for a cAMP binding site on an antibody or cAMP binding protein and as such have a limited dynamic range. Here, we describe the optimisation of the commercially-available LANCE cAMP detection kit (PerkinElmer) to enable detection in cell lysates. This kit has been designed for use with live cells, with detection reagents applied to cells without wash steps. The standard protocol therefore requires that all assay reagents are compatible with the antibody and the final fluorescent detection stage, limiting the range of assay media and test compounds that can be utilised. The entire experiment must be repeated if cAMP levels fall outside the limited dynamic range. Here we describe a modified protocol that enables the assay to be performed on cell lysates, thereby overcoming these limitations. In this modified protocol, cells are stimulated for a cAMP response in standard media/buffers, washed and then lysed. The cell lysate is then assayed using a modified protocol for the LANCE cAMP detection kit. Samples were tested for stability following a freeze-thaw cycle. The modified LANCE cAMP detection protocol gives a reproducible measurement of cAMP in cell lysate. Lysate samples remain stable when stored at -80°C. Separating the stimulation and detection phases of this cAMP assay allows a vast array of cell stimulation conditions to be tested. The lysate-modified protocol for the LANCE cAMP detection kit therefore increases the flexibility, versatility and convenience of the assay. As samples are insensitive to freeze-thaw, it enables retesting of samples under different dilution conditions to ensure that all samples remain within the dynamic range of the standard curve. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Determination of stannous tin in radiopharmaceutical cold kits

    International Nuclear Information System (INIS)

    Farrant, A.J.

    1979-01-01

    Two methods for determining stannous tin in 'cold kits', used for the preparation of Tc-99m labelled radiopharmaceuticals, have been developed. Both are based on the direct titration of the Sn2 in solution. In the first method titration is with N-bromosuccinimide. Of the materials commonly used as cold kits only albumin has been found to interfere with the determination. The second method is a standard iodometric titration in which starch is used as indicator. None of the materials tested interfere with this procedure. The N-bromosuccinimide method is the method of choice as the re-agent, a solid, can be used without prior standardization. Iodine solution must be standardized daily. The paper describes in detail the methods used and gives examples of kits in which the Sn2 levels have been determined using the described procedures

  1. Developing teaching kit on the use of micro-hydro generator in remote area

    Directory of Open Access Journals (Sweden)

    Desak Made Megawati

    2017-04-01

    Full Text Available The study aimed at: (1 identifying the criteria of teaching kit feasibility for the advantages of micro-hydro generator in remote area; and (2 identifying the effectiveness of teaching kit implementation on the use of micro-hydro generator in remote area in order to improve the students’ concept mastery on SMP Negeri 1 Rampi South Sulawesi. The study was a research and development that adapted the 4D model, which consisted of define, design, develop, and disseminate. The teaching kit that had been developed was a syllabus, lesson plans, student’s worksheet, and assessment instrument. For the data gathering, the researcher implemented the non-test technique, in the form of product validation sheet, student’s worksheet readability questionnaire sheet, teaching implementation sheet, and test technique, in the form of concept mastery test item sheet. The results of the study show that: (1 the teaching kit on the use of micro-hydro generator in remote area that has been developed falls into the “Very Good” category for syllabus, lesson plan, and student’s worksheet; and (2 the implementation of the teaching kit on the use of micro-hydro generator in remote area has been effective to improve the students’ concept mastery in SMP Negeri 1 Rampi South Sulawesi.

  2. Performance of immunoassay kits for site characterization and remediation

    International Nuclear Information System (INIS)

    Waters, L.C.; Palausky, A.; Counts, R.W.; Jenkins, R.A.

    1995-01-01

    The US Department of Energy (DOE) is supporting efforts to identify, validate and implement the use of effective, low-cost alternatives to currently used analytical methods for environmental management. As part of that program, we have evaluated the performances of a number of immunoassay (IA) kits with specificities for environmental contaminants of concern to the DOE. The studies were done in the laboratory using both spiked and field test samples. The analyte specificity and manufacturers of the kits evaluated were the following: mercury, BioNebraska; polychlorinated biphenyls (PCBs), EnSys and Millipore; petroleum fuel hydrocarbons, Millipore and Ohmicron; and polyaromatic hydrocarbons (PAHs), Ohmicron and Millipore. The kits were used in either a semiquantitative or quantitative format according to the preference of the manufacturers

  3. A critical appraisal of a further three new commercial digoxin radioimmunoassay kits with reference to cross-reacting substances

    International Nuclear Information System (INIS)

    Wood, W.G.; Wachter, C.

    1979-01-01

    A further 3 digoxin radioimmunoassay (RIA) kits have been evaluated for performance and cross-reaction with digitoxin, spironolactone, canrenone and furosemide (Lasix-Hoechst). Effects of serum protein concentrations have also been tested. The kits tested were from the following manufacturers: A) Diagnostic Products Corporation Digoxin RIA Kit. B) Byk-Mallinckrodt SPAC Digoxin Kit. C) Boehringer-Mannheim Digoxin RIA Kit. All kits used a 125 I-labelled tracer. Kit A used a conventional liquid phase system using double-antibody separation for bound and free drug. Kits B and C used a solid-phase antibody coated tube method. All kits showed a lower cross-reaction to digitoxin than quoted by the manufacturer. Cross-reaction to spironolactone (Aldactone - Boehringer-Mannheim) was less than 1.50 nmol/l at a serum concentration of 125 mg/l Aldactone in all 3 kits. The cross-reaction to canrenone was somewhat higher, 5.2 nmol/l 'digoxin' being measured in one kit at a serum canrenone concentration of 125 mg/l. There was no cross-reaction with furosemide in any kit, even at a serum concentration of 5 g/l. The coated-tube assays were affected by serum albumin and globulin concentration changes, one kit showing a difference of over 50% binding in the range 1-20% albumin. The double-antibody kit did not show dependence on the concentration of these proteins. All kits measured digoxin with good reproducibility in the range 0.40-10.0 nmol/l. (orig.) [de

  4. FlowGo: An Educational Kit for Fluid Dynamics and Heat Transfer

    Science.gov (United States)

    Guri, Dominic; Portsmore, Merredith; Kemmerling, Erica

    2015-11-01

    The authors have designed and prototyped an educational toolkit that will help middle-school-aged students learn fundamental fluid mechanics and heat transfer concepts in a hands-on play environment. The kit allows kids to build arbitrary flow rigs to solve fluid mechanics and heat transfer challenge problems. Similar kits for other engineering fields, such as structural and electrical engineering, have resulted in pedagogical improvements, particularly in early engineering education, where visual demonstrations have a significant impact. Using the FlowGo kit, students will be able to conduct experiments and develop new design ideas to solve challenge problems such as building plant watering systems or modeling water and sewage reticulation. The toolkit consists of components such as tubes, junctions, and reservoirs that easily snap together via a modular, universal connector. Designed with the Massachusetts K-12 science standards in mind, this kit is intended to be affordable and suitable for classroom use. Results and user feedback from students conducting preliminary tests of the kit will be presented.

  5. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung

    2000-01-01

    Although α-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for α-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for α-fetoprotein (Riakey AFP IRMA CT R , Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum α-fetoprotein measurement using Riakey AFP IRMA CT R kit. The values of α-fetoprotein measured by Riakey AFP IRMA CT R kit were compared with those measured by two foreign commercial kits (α-fetoproteina of Radim and α-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100±10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of α-fetoprotein by Riakey AFP IRMA CT R and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for α-fetoprotein, Riakey AFP IRMA CT R , performed well for clinical use.=20

  6. Create an Emergency Kit

    Science.gov (United States)

    ... models take up less space in your kit. Cell phone. Always carry a cell phone and let people know where you are going ... pump in your emergency kit. Remember that despite safety standards and careful monitoring, these devices can fail. ...

  7. Fundamental studies on the development of C-peptide radioimmunoassay kit

    International Nuclear Information System (INIS)

    Nakazawa, Nobuhiko; Maki, Kentaro; Ogawa, Hiroshi; Ikeda, Osamu

    1976-01-01

    We have studied the development of the C-peptide radioimmunoassay kit which is usable in the pancreatic function test with satisfactory results. The C-peptide antiserum was prepared by immunizing rabbits with synthetic human connecting peptide. The antiserum revealed no cross reaction with any C-peptides other than human C-peptide, porcine insulin and gastrointestinal hormone, and showed high specificity to human C-peptide. We adopted the double antibody method in B,F separation, and chose 4 0 C, 48 hrs. for 1st. incubation and 4 0 C, 24 hrs. for 2nd. incubation. On this kit, the assay range was 0.5 ng/ml-30 ng/ml, the recovery rate was 98.4%-107.8% in the recovery test, the coefficient of variance was 6.2% in the intra assay and was 7.6% in the inter assay. We think this kit is sufficiently usable to assay C-peptide in blood. (auth.)

  8. Fundamental studies on the development of C-peptide radioimmunoassay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, N; Maki, K; Ogawa, H; Ikeda, O [Daiichi Radioisotope Labs. Ltd., Tokyo (Japan)

    1976-05-01

    We have studied the development of the C-peptide radioimmunoassay kit which is usable in the pancreatic function test with satisfactory results. The C-peptide antiserum was prepared by immunizing rabbits with synthetic human connecting peptide. The antiserum revealed no cross reaction with any C-peptides other than human C-peptide, porcine insulin and gastrointestinal hormone, and showed high specificity to human C-peptide. We adopted the double antibody method in B,F separation, and chose 4/sup 0/C, 48 hrs. for 1st. incubation and 4/sup 0/C, 24 hrs. for 2nd. incubation. On this kit, the assay range was 0.5 ng/ml-30 ng/ml, the recovery rate was 98.4%-107.8% in the recovery test, the coefficient of variance was 6.2% in the intra assay and was 7.6% in the inter assay. We think this kit is sufficiently usable to assay C-peptide in blood.

  9. Gene expression in gastrointestinal stromal tumors is distinguished by KIT genotype and anatomic site.

    Science.gov (United States)

    Antonescu, Cristina R; Viale, Agnes; Sarran, Lisa; Tschernyavsky, Sylvia J; Gonen, Mithat; Segal, Neil H; Maki, Robert G; Socci, Nicholas D; DeMatteo, Ronald P; Besmer, Peter

    2004-05-15

    Gastrointestinal stromal tumors (GISTs) are specific KIT expressing and KIT-signaling driven mesenchymal tumors of the human digestive tract, many of which have KIT-activating mutations. Previous studies have found a relatively homogeneous gene expression profile in GIST, as compared with other histological types of sarcomas. Transcriptional heterogeneity within clinically or molecularly defined subsets of GISTs has not been previously reported. We tested the hypothesis that the gene expression profile in GISTs might be related to KIT genotype and possibly to other clinicopathological factors. An HG-U133A Affymetrix chip (22,000 genes) platform was used to determine the variability of gene expression in 28 KIT-expressing GIST samples from 24 patients. A control group of six intra-abdominal leiomyosarcomas was also included for comparison. Statistical analyses (t tests) were performed to identify discriminatory gene lists among various GIST subgroups. The levels of expression of various GIST subsets were also linked to a modified version of the growth factor/KIT signaling pathway to analyze differences at various steps in signal transduction. Genes involved in KIT signaling were differentially expressed among wild-type and mutant GISTs. High gene expression of potential drug targets, such as VEGF, MCSF, and BCL2 in the wild-type group, and Mesothelin in exon 9 GISTs were found. There was a striking difference in gene expression between stomach and small bowel GISTs. This finding was validated in four separate tumors, two gastric and two intestinal, from a patient with familial GIST with a germ-line KIT W557R substitution. GISTs have heterogeneous gene expression depending on KIT genotype and tumor location, which is seen at both the genomic level and the KIT signaling pathway in particular. These findings may explain their variable clinical behavior and response to therapy.

  10. 7 CFR 28.423 - Middling Spotted Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Middling Spotted Color. 28.423 Section 28.423... REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Standards Spotted Cotton § 28.423 Middling Spotted Color. Middling Spotted Color is color which is within the range represented by a set of samples in the custody of...

  11. Education Payload Operation - Kit D

    Science.gov (United States)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Kit D (EPO-Kit D) includes education items that will be used to support the live International Space Station (ISS) education downlinks and Education Payload Operation (EPO) demonstrations onboard the ISS. The main objective of EPO-Kit D supports the National Aeronautics and Space Administration (NASA) goal of attracting students to study and seek careers in science, technology, engineering, and mathematics.

  12. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    Science.gov (United States)

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart

  13. The need for standardisation of methodology and components in commercial radioimmunoassay kits

    International Nuclear Information System (INIS)

    Wood, W.G.; Marschner, I.; Scriba, P.C.

    1977-01-01

    The problems arising from increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. The problems arising in various RIAs differ according to the substance under test. The quality of individual components is often good, although methodology is often not optimal and contains short-cuts, which although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modification of methodology often leads to major improvements in sensitivity and precision, and this has been demonstrated in the case of three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that in many imported quality control sera from the USA no values have been ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The deductions from this study are that a standardisation of kit components and assay methods is desirable in order to allow comparison of results between laboratories using different kits. (orig.) [de

  14. Spot Weight Adaptation for Moving Target in Spot Scanning Proton Therapy.

    Science.gov (United States)

    Morel, Paul; Wu, Xiaodong; Blin, Guillaume; Vialette, Stéphane; Flynn, Ryan; Hyer, Daniel; Wang, Dongxu

    2015-01-01

    This study describes a real-time spot weight adaptation method in spot-scanning proton therapy for moving target or moving patient, so that the resultant dose distribution closely matches the planned dose distribution. The method proposed in this study adapts the weight (MU) of the delivering pencil beam to that of the target spot; it will actually hit during patient/target motion. The target spot that a certain delivering pencil beam may hit relies on patient monitoring and/or motion modeling using four-dimensional (4D) CT. After the adapted delivery, the required total weight [Monitor Unit (MU)] for this target spot is then subtracted from the planned value. With continuous patient motion and continuous spot scanning, the planned doses to all target spots will eventually be all fulfilled. In a proof-of-principle test, a lung case was presented with realistic temporal and motion parameters; the resultant dose distribution using spot weight adaptation was compared to that without using this method. The impact of the real-time patient/target position tracking or prediction was also investigated. For moderate motion (i.e., mean amplitude 0.5 cm), D95% to the planning target volume (PTV) was only 81.5% of the prescription (RX) dose; with spot weight adaptation PTV D95% achieves 97.7% RX. For large motion amplitude (i.e., 1.5 cm), without spot weight adaptation PTV D95% is only 42.9% of RX; with spot weight adaptation, PTV D95% achieves 97.7% RX. Larger errors in patient/target position tracking or prediction led to worse final target coverage; an error of 3 mm or smaller in patient/target position tracking is preferred. The proposed spot weight adaptation method was able to deliver the planned dose distribution and maintain target coverage when patient motion was involved. The successful implementation of this method would rely on accurate monitoring or prediction of patient/target motion.

  15. Spot Weight Adaptation for Moving Target in Spot Scanning Proton Therapy

    Directory of Open Access Journals (Sweden)

    Paul eMorel

    2015-05-01

    Full Text Available Purpose: This study describes a real-time spot weight adaptation method in spot-scanning proton therapy for moving target or moving patient, so that the resultant dose distribution closely matches the planned dose distribution. Materials and Methods: The method proposed in this study adapts the weight (MU of the delivering pencil beam to that of the target spot it will actually hit during patient/target motion. The target spot a certain delivering pencil beam may hit relies on patient monitoring and/or motion modeling using four-dimensional (4D CT. After the adapted delivery, the required total weight (MU for this target spot is then subtracted from the planned value. With continuous patient motion and continuous spot scanning, the planned doses to all target spots will eventually be all fulfilled. In a proof-of-principle test, a lung case was presented with realistic temporal and motion parameters; the resultant dose distribution using spot weight adaptation was compared to that without using this method. The impact of the real-time patient/target position tracking or prediction was also investigated.Results: For moderate motion (i.e., mean amplitude 0.5 cm, D95% to the planning target volume (PTV was only 81.5% of the prescription (RX dose; with spot weight adaptation PTV D95% achieves 97.7%RX. For large motion amplitude (i.e., 1.5 cm, without spot weight adaptation PTV D95% is only 42.9% of RX; with spot weight adaptation, PTV D95% achieves 97.7%RX. Larger errors in patient/target position tracking or prediction led to worse final target coverage; an error of 3mm or smaller in patient/target position tracking is preferred. Conclusion: The proposed spot weight adaptation method was able to deliver the planned dose distribution and maintain target coverage when patient motion was involved. The successful implementation of this method would rely on accurate monitoring or prediction of patient/target motion.

  16. Genotoxic evaluation of two oral antidiabetic agents in the Drosophila wing spot test.

    Science.gov (United States)

    Gürbüzel, Mehmet; Çapoğlu, Ilyas; Kızılet, Halit; Halıcı, Zekai; Özçiçek, Fatih; Demirtaş, Levent

    2014-05-01

    In this study, two sulfonylureas--glimepiride and glipizide--commonly used in type 2 diabetes mellitus were investigated for genotoxicity in the Drosophila wing spot test. For this purpose, three-day-old transheterozygous larvae were treated with three mutagenic compounds, and the results obtained were compared with the control group. Mutational or recombinogenic changes were recorded in two recessive genes--multiple wing hairs (mwh) and flare (flr (3)). Two recessive markers were located on the left arm of chromosome 3, mwh in map position 0.3, and flare-3 (flr3) at 38.8, while the centromere was located in position 47.7. Wing spot tests are targeted on the loss of heterozygosity, which may be grounded in different genetic mechanisms such as mutation, mitotic recombination, deletion, half-translocation, chromosome loss, or nondisjunction. Genetic changes formatting in somatic cells of the imaginal discs cause nascence different mutant cloning in different body parts of adult flies. Our in vivo experiments demonstrated that glimepiride and glipizide show the genotoxicity, which is especially dependent on homologous somatic recombination.

  17. Molecular Alterations of KIT Oncogene in Gliomas

    Directory of Open Access Journals (Sweden)

    Ana L. Gomes

    2007-01-01

    Full Text Available Gliomas are the most common and devastating primary brain tumours. Despite therapeutic advances, the majority of gliomas do not respond either to chemo or radiotherapy. KIT, a class III receptor tyrosine kinase (RTK, is frequently involved in tumourigenic processes. Currently, KIT constitutes an attractive therapeutic target. In the present study we assessed the frequency of KIT overexpression in gliomas and investigated the genetic mechanisms underlying KIT overexpression. KIT (CD117 immunohistochemistry was performed in a series of 179 gliomas of various grades. KIT activating gene mutations (exons 9, 11, 13 and 17 and gene amplification analysis, as defined by chromogenic in situ hybridization (CISH and quantitative real-time PCR (qRT-PCR were performed in CD117 positive cases. Tumour cell immunopositivity was detected in 15.6% (28/179 of cases, namely in 25% (1/4 of pilocytic astrocytomas, 25% (5/20 of diffuse astrocytomas, 20% (1/5 of anaplastic astrocytomas, 19.5% (15/77 of glioblastomas and one third (3/9 of anaplastic oligoastrocytomas. Only 5.7% (2/35 of anaplastic oligodendrogliomas showed CD117 immunoreactivity. No association was found between tumour CD117 overexpression and patient survival. In addition, we also observed CD117 overexpression in endothelial cells, which varied from 0–22.2% of cases, being more frequent in high-grade lesions. No KIT activating mutations were identified. Interestingly, CISH and/or qRT-PCR analysis revealed the presence of KIT gene amplification in 6 glioblastomas and 2 anaplastic oligoastrocytomas, corresponding to 33% (8/24 of CD117 positive cases. In conclusion, our results demonstrate that KIT gene amplification rather than gene mutation is a common genetic mechanism underlying KIT expression in subset of malignant gliomas. Further studies are warranted to determine whether glioma patients exhibiting KIT overexpression and KIT gene amplification may benefit from therapy with anti-KIT RTK

  18. Radiology seminars using teaching kits

    International Nuclear Information System (INIS)

    Munro, T.G.

    1989-01-01

    Clinco-radiological seminars are an effective method of teaching medical students. However, in busy departments it is often difficult to provide enough radiologists for small group instruction. This can be facilitated by the use of prepared teaching kits. Each kit contains a set of duplicated films and a syllabus which gives a short clinical history for each patient and a series of questions to be used to direct the discussion. Each diagnostic problem is chosen to demonstrate core material. We have been using these teaching kits for organ system teaching in the preclerkship year. Teaching kits offer several advantages. They make it easier to recruit seminar leaders through efficient use of their time. The use of duplicated films and a syllabus ensures that all students cover the same material. The syllabus can be used to generate examination questions for reinforcement of important concepts. The kits are also available to students to review alone and can be readily updated as required

  19. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  20. Evaluation of the AGCU Expressmarker 16 and 22 PCR Amplification Kits Using Biological Samples Applied to FTA Micro Cards in Reduced Volume Direct PCR Amplification Reactions

    Directory of Open Access Journals (Sweden)

    Samantha J Ogden

    2015-01-01

    /Kruskal-Wallis test was used. Statistical significance was set at P < 0.05. Confidence intervals for mean values were set at 95%. On using reduced volume PCR reactions in combination with dried blood spots applied to FTA sample collection cards, both the EX16 and EX22 kits were shown to generate STR profiles of sufficient quality to allow entry into National DNA databases. The performance of both EX16 and EX22 was comparable to that of the PP21 System. This study demonstrates the successful use of the Wuxi AGCU ScienTech Incorporation EX16 and EX22 kits in reduced PCR reaction volumes with complex biological samples applied to chemically impregnated FTA sample collection cards.

  1. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    Although {alpha}-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for {alpha}-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for {alpha}-fetoprotein (Riakey AFP IRMA CT{sup R}, Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum {alpha}-fetoprotein measurement using Riakey AFP IRMA CT{sup R} kit. The values of {alpha}-fetoprotein measured by Riakey AFP IRMA CT{sup R} kit were compared with those measured by two foreign commercial kits ({alpha}-fetoproteina of Radim and {alpha}-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100{+-}10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of {alpha}-fetoprotein by Riakey AFP IRMA CT{sup R} and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for {alpha}-fetoprotein, Riakey AFP IRMA CT{sup R}, performed well for clinical use.

  2. Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail

  3. Quantitative structure-activity relationships for toxicity and genotoxicity of halogenated aliphatic compounds: wing spot test of Drosophila melanogaster.

    Science.gov (United States)

    Chroust, Karel; Pavlová, Martina; Prokop, Zbynek; Mendel, Jan; Bozková, Katerina; Kubát, Zdenek; Zajícková, Veronika; Damborský, Jiri

    2007-02-01

    Halogenated aliphatic compounds were evaluated for toxic and genotoxic effects in the somatic mutation and recombination test employing Drosophila melanogaster. The tested chemicals included chlorinated, brominated and iodinated; mono-, di- and tri-substituted; saturated and unsaturated alkanes: 1,2-dibromoethane, 1-bromo-2-chloroethane, 1-iodopropane, 2,3-dichloropropene, 3-bromo-1-propene, epibromohydrin, 2-iodobutane, 3-chloro-2-methylpropene, 1,2,3-trichloropropane, 1,2-dichloroethane, 1,2-dichlorobutane, 1-chloro-2-methylpropane, 1,3-dichloropropane, 1,2-dichloropropane, 2-chloroethymethylether, 1-bromo-2-methylpropane and 1-chloropentane. N-methyl-N-nitrosourea served as the positive and distilled water as the negative control. The set of chemicals for the toxicological testing was selected by the use of statistical experiment design. Group of unsaturated aliphatic hydrocarbons were generally more toxic than saturated analogues. The genotoxic effect was observed with 14 compounds in the wing spot test, while 3 substances did not show any genotoxicity by using the wing spot test at 50% lethal concentration. The highest number of wing spots was observed in genotoxicity assay with 1-bromo-2-chloroethane, 1,2-dichloroethane, 1,2-dibromoethane and 1-iodopropane. Nucleophilic superdelocalizability calculated by quantum mechanics appears to be a good parameter for prediction of both toxicity and genotoxicity effects of halogenated aliphatic compounds.

  4. 46 CFR 184.710 - First-aid kits.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  5. Imaging evaluation of infants with neuroblastoma detected by VMA screening spot test

    International Nuclear Information System (INIS)

    Fujioka, M.; Saiki, N.; Aihara, T.; Yamamoto, K.

    1988-01-01

    In the Saitama Prefecture in Japan, VMA (vanillyl manderic acid) screening spot test for detection of neuroblastoma has been performed in 173,046 infants in the years 1981-1986 and 15 infants were found to have neuroblastoma. Two infants had mediastinal tumors and the remainder, 13, had intraabdominal tumors. Only 7 infants had palpable masses. Although CT was documented to be the best imaging procedure to provide sufficient information for treatment, conventional radiographic examinations of the chest and abdomen, and abdominal ultrasonography were able, as initial imaging procedures, to detect reasonably small neuroblastomas in infants with a positive VMA screening test. (orig.)

  6. Technical Note: Validation of halo modeling for proton pencil beam spot scanning using a quality assurance test pattern

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Liyong, E-mail: linl@uphs.upenn.edu; Huang, Sheng; Kang, Minglei; Solberg, Timothy D.; McDonough, James E.; Ainsley, Christopher G. [Department of Radiation Oncology, University of Pennsylvania, 3400 Civic Center Boulevard, Philadelphia, Pennsylvania 19104 (United States)

    2015-09-15

    Purpose: The purpose of this paper is to demonstrate the utility of a comprehensive test pattern in validating calculation models that include the halo component (low-dose tails) of proton pencil beam scanning (PBS) spots. Such a pattern has been used previously for quality assurance purposes to assess spot shape, position, and dose. Methods: In this study, a scintillation detector was used to measure the test pattern in air at isocenter for two proton beam energies (115 and 225 MeV) of two IBA universal nozzles (UN #1 and UN #2). Planar measurements were compared with calculated dose distributions based on the weighted superposition of location-independent (UN #1) or location-dependent (UN #2) spot profiles, previously measured using a pair-magnification method and between two nozzles. Results: Including the halo component below 1% of the central dose is shown to improve the gamma-map comparison between calculation and measurement from 94.9% to 98.4% using 2 mm/2% criteria for the 115 MeV proton beam of UN #1. In contrast, including the halo component below 1% of the central dose does not improve the gamma agreement for the 115 MeV proton beam of UN #2, due to the cutoff of the halo component at off-axis locations. When location-dependent spot profiles are used for calculation instead of spot profiles at central axis, the gamma agreement is improved from 98.0% to 99.5% using 2 mm/2% criteria. The two nozzles clearly have different characteristics, as a direct comparison of measured data shows a passing rate of 89.7% for the 115 MeV proton beam. At 225 MeV, the corresponding gamma comparisons agree better between measurement and calculation, and between measurements in the two nozzles. Conclusions: In addition to confirming the primary component of individual PBS spot profiles, a comprehensive test pattern is useful for the validation of the halo component at off-axis locations, especially for low energy protons.

  7. Quality control of radioimmunoassay kits of pituitary hormones

    International Nuclear Information System (INIS)

    Caso Pena, R.; Arranz Calzado, C.

    1997-01-01

    The present work describe the quality control procedures carried out on three RIA-Kits by the Isotopes Centre of Cuba, The subject matter of study were ;: were: LH-RIA-Kit, FSH-RIA-Kit and Prolactin- RIA -Kit. The controls have included the characterization of the 125 I labelled hormones the specific antibodies, the 2 nd antibodies, the standards curves and the control serum. For the validation of these Kits were used reference standards from the WHO (World Health Organizations) and Kits from CIS company (France) based on the IRMA assays technologies . The results obtained allow us encourage the reliability of RIA-Kits

  8. 46 CFR 121.710 - First-aid kits.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit... kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A...

  9. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    Science.gov (United States)

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  10. ISS Expedition 08 Press Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — Press kit for ISS mission Expedition 08 from 10/2003-04/2004. Press kits contain information about each mission overview, crew, mission timeline, benefits, and media...

  11. [Development of a laboratory test on dried blood spots for facilitating early diagnosis of alpha-1-antitrypsin deficiency].

    Science.gov (United States)

    Balduyck, Malika; Chapuis Cellier, Colette; Roche, Denis; Odou, Marie-Françoise; Joly, Philippe; Madelain, Vincent; Vergne, Anita; Nouadje, Georges; Lafitte, Jean-Jacques; Porchet, Nicole; Beaune, Philippe; Zerimech, Farid

    2014-01-01

    Alpha- 1-antitrypsin (A1AT) deficiency is a hereditary autosomal codominant genetic disorder resulting in low circulating levels of A1AT and leading to lung and/or liver disease. It remains underdiagnosed and only 5 to 10% of PIZZ patients, the most common form of severe A1AT deficiency, would be actually identified in France. Facilitating early diagnosis of A1AT deficiency would allow a better management of this disease; therefore we have developed and standardized in three laboratories involved in this study, a diagnostic test on dried blood spots (DBS) including quantitative A1AT measurement, phenotyping by IEF electrophoresis and, if necessary, genotyping by SERPINA1 gene sequencing. We performed a quantitative assay on 90 DBS samples by immunoturbidimetric or immunonephelometric methods. We demonstrated that both methods were suitable for this type of sampling and the results obtained were highly correlated (R(2)>0.9) between the three laboratories: for a target value of 1.00 g/L, the results obtained from the three laboratories were between 1.00 and 1.02 g/L. Phenotyping and genotyping were performed under redefined operating conditions and adapted to the analysis of DBS samples. The results were comparable with those obtained for venous blood samples. Following this work, it becomes possible to provide pulmonologists with a reliable kit to perform a capillary blood sampling on filter paper which would allow a large-scale screening of A1AT deficiency in the population particularly affected by this genetic condition.

  12. Windows 7 resource kit

    CERN Document Server

    Northrup, Tony; Honeycutt, Jerry; Wilson, Ed

    2009-01-01

    In-depth and comprehensive, this RESOURCE KIT delivers the information you need to administer your Windows 7 system. You get authoritative technical guidance from those who know the technology best-Microsoft Most Valuable Professionals (MVPs) and the Windows 7 product team-along with essential scripts and resources. In addition, "Direct from the Source" sidebars offer deep insights and troubleshooting tips from the Windows 7 team. Get expert guidance on how to: Use Microsoft Deployment Toolkit best practices and tools. Plan user-state migration and test application compatibility.

  13. Comparação de kits ELISA® comerciais para anticorpos no soro e leite com um teste coproparasitológico em bovinos naturalmente infectados por Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Cíntia das C. Bernardo

    2013-01-01

    Full Text Available A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92 sangue (92 e leite (43 de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (p<0,0001 em relação ao exame coproparasitológico. A sensibilidade dos Kits foi de 100%, porém possuíram baixa especificidade, 42,85 e 30% para o soro e leite respectivamente. O coeficiente de kappa mostrou concordância sofrível para os testes de soro (0,33 e de leite (0,21. Os valores preditivos positivos dos kits para soro e leite foram, respectivamente, 44,61 e 38,23% e, os valores preditivos negativos de 100% para ambos os testes. Apesar da maior sensibilidade dos kits ELISA comerciais e, destes apresentarem diferença em relação ao exame coproparasitológico na detecção dos animais positivos para F. hepatica, a escolha de um teste diagnóstico deve considerar o custo benefício. Quando se trata da presença de parasitismo em rebanhos, o tratamento é aplicado

  14. Build an Emergency Preparedness Kit

    Science.gov (United States)

    ... In addition to the items listed above, a vehicle kit should include: -fire extinguisher. -booster cables and tow rope. -compass and road maps. -shovel. -tire repair kit and pump. -extra clothing to keep dry. - ...

  15. An improved 99mTc-Aprotinin kit formulation: quality control analysis of cold kit shelf life and radiotracer stability

    International Nuclear Information System (INIS)

    Smyth, D.R.; Tsopelas, C.

    2005-01-01

    Aprotinin is a small protein that inhibits serine proteases and has been shown to bind to amyloid fibrils of varying chemical composition in-vitro. 99 mTc-aprotinin has demonstrated potential for imaging cardiac and pleuropulmonary AL amyloidosis and other forms of amyloidosis present as deposits in joints, the tongue or intestines and other sites excluding the kidneys and liver. Radiolabelling of aprotinin was previously achieved by addition of 99 mTc-pertech-netate to an alkaline mixture of Trasylol (aprotinin injection) and stannous chloride, followed by a necessary filtration step after 20-30 minutes. We have developed a modified cold kit formulation, utilising pharmaceutical starting materials, that provides a more convenient and efficient radiolabelling procedure where filtration is not required prior to injection. The shelf life of the cold kits was validated after storage in a freezer. The reducing agent used was stannous-pyrophosphate (PYP) and the alkaline buffer was a phosphate-glycine mixture (pH 10.5). Quality control testing of the cold kits was performed after 0, 1, 2, 3 and 6 months storage by assessing the % RCP of 99 mTc-apro-tinin by ITLC-SG. Radiotracer stability was examined in the same way 25, 85 and 265 minutes post reconstitution (pr) via a three strip system employing acetone, saline and ammonia:ethanol:water mixture (1:2:5). A rapid quality control cartridge method was also investigated. Radiolabelling of the cold kits yielded RCP > 95% at 25 mins pr and all other time points, from a formulation that avoided a filtration step. The impurities were quantified as TcO., ( 99 mTc-PYP (< 0.7%) by paper methods. The improved Tc-aprotinin kit formulation has greater convenience and efficiency in the clinical setting

  16. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    Science.gov (United States)

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  17. Spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB

    Science.gov (United States)

    Harris, B.W.

    1984-11-29

    A simple, sensitive and specific spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB, is described. Upon the application of the composition of matter of the subject invention to samples containing in excess of 0.1 mg of this explosive, a bright orange color results. Interfering species such as TNT and Tetryl can be removed by first treating the sample with a solvent which does not dissolve the TATB, but readily dissolves these interfering explosives.

  18. Gene expression analysis identifies new candidate genes associated with the development of black skin spots in Corriedale sheep.

    Science.gov (United States)

    Peñagaricano, Francisco; Zorrilla, Pilar; Naya, Hugo; Robello, Carlos; Urioste, Jorge I

    2012-02-01

    The white coat colour of sheep is an important economic trait. For unknown reasons, some animals are born with, and others develop with time, black skin spots that can also produce pigmented fibres. The presence of pigmented fibres in the white wool significantly decreases the fibre quality. The aim of this work was to study gene expression in black spots (with and without pigmented fibres) and white skin by microarray techniques, in order to identify the possible genes involved in the development of this trait. Five unrelated Corriedale sheep were used and, for each animal, the three possible comparisons (three different hybridisations) between the three samples of interest were performed. Differential gene expression patterns were analysed using different t-test approaches. Most of the major genes with well-known roles in skin pigmentation, e.g. ASIP, MC1R and C-KIT, showed no significant difference in the gene expression between white skin and black spots. On the other hand, many of the differentially expressed genes (raw P-value spots. The gene expression of C-FOS and KLF4, transcription factors involved in the cellular response to external factors such as ultraviolet light, was validated by quantitative polymerase chain reaction (PCR). This exploratory study provides a list of candidate genes that could be associated with the development of black skin spots that should be studied in more detail. Characterisation of these genes will enable us to discern the molecular mechanisms involved in the development of this feature and, hence, increase our understanding of melanocyte biology and skin pigmentation. In sheep, understanding this phenomenon is a first step towards developing molecular tools to assist in the selection against the presence of pigmented fibres in white wool.

  19. Ex post and ex ante willingness to pay (WTP) for the ICT Malaria Pf/Pv test kit in Myanmar.

    Science.gov (United States)

    Cho-Min-Naing; Lertmaharit, S; Kamol-Ratanakul, P; Saul, A J

    2000-03-01

    Willingness to pay (WTP) for the ICT Malaria Pf/Pv test kit was assessed by the contingent valuation method using a bidding game approach in two villages in Myanmar. Kankone (KK) village has a rural health center (RHC) and Yae-Aye-Sann (YAS) is serviced by community health worker (CHW). The objectives were to assess WTP for the ICT Malaria Pf/Pv test kit and to determine factors affecting the WTP. In both villages WTP was assessed in two different conditions, ex post and ex ante. The ex post WTP was assessed at an RHC in the KK village and at the residence of a CHW in the YAS village on patients immediately following diagnosis of malaria. The ex ante WTP was assessed by household interviews in both villages on people with a prior history of malaria. Ordinary least squares (OLS) multiple regression analysis was used to analyze factors affecting WTP. The WTP was higher in ex post conditions than ex ante in both villages. WTP was significantly positively associated with the average monthly income of the respondents and severity of illness in both ex post and ex ante conditions (p WTP (p < 0.05) in the ex post condition in the RHC survey in KK village.

  20. A simple field kit for the determination of drug susceptibility in Plasmodium falciparum.

    Science.gov (United States)

    Nguyen-Dinh, P; Magloire, R; Chin, W

    1983-05-01

    A field kit has been developed which greatly simplifies the performance of the 48-hour in vitro test for drug resistance in Plasmodium falciparum. The kit uses an easily reconstituted lyophilized culture medium, and requires only a fingerprick blood sample. In parallel tests with 13 isolates of P. falciparum in Haiti, the new technique had a success rate equal to that of the previously described method, with comparable results in terms of parasite susceptibility in vitro to chloroquine and pyrimethamine.

  1. Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.

    Science.gov (United States)

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2015-12-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.

  2. A Novel Location-Awareness Method Using CubeSats for Locating the Spot Beam Emitters of Geostationary Communications Satellites

    Directory of Open Access Journals (Sweden)

    Weicai Yang

    2018-01-01

    Full Text Available As more spacecraft are launched into the Geostationary Earth Orbit (GEO belt, the possibility of fatal collisions or unnecessary interference between spacecraft increases. In this paper, a new location-awareness method that uses CubeSats is proposed to assist with radiofrequency (RF domain verification by means of awareness and identification of the positions of the spot beam emitters of communications satellites in geostationary orbit. By flying a CubeSat (or a constellation of CubeSats through the coverage area of a spot beam, the spot beam emitter’s position is identified and the spot beam’s pattern knowledge is characterized. The geometry, the equations of motion of the spacecraft, the measurement process, and the filtering equations in a location system are addressed with respect to the location methods investigated in this study. A realistic scenario in which a CubeSat receives signals from GEO communications satellites is simulated using the Systems Tool Kit (STK. The results of the simulation and the analysis presented in this study provide a thorough verification of the performance of the location-awareness method.

  3. Improved simulation method of automotive spot weld failure with an account of the mechanical properties of spot welds

    Science.gov (United States)

    Wu, H.; Meng, X. M.; Fang, R.; Huang, Y. F.; Zhan, S.

    2017-12-01

    In this paper, the microstructure and mechanical properties of spot weld were studied, the hardness of nugget and heat affected zone (HAZ) were also tested by metallographic microscope and microhardness tester. The strength of the spot weld with the different parts' area has been characterized. According to the experiments result, CAE model of spot weld with HAZ structure was established, and simulation results of different lap-shear CAE models were analyzed. The results show that the spot weld model which contained the HAZ has good performance and more suitable for engineering application in spot weld simulation.

  4. Collimator kit

    International Nuclear Information System (INIS)

    Jonker, R.R.

    1976-01-01

    A collimator kit having a number of parts which may be assembled in various combinations to provide focusing collimators with different performance characteristics for radioisotope imaging apparatus is described

  5. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  6. Statistical hot spot analysis of reactor cores

    International Nuclear Information System (INIS)

    Schaefer, H.

    1974-05-01

    This report is an introduction into statistical hot spot analysis. After the definition of the term 'hot spot' a statistical analysis is outlined. The mathematical method is presented, especially the formula concerning the probability of no hot spots in a reactor core is evaluated. A discussion with the boundary conditions of a statistical hot spot analysis is given (technological limits, nominal situation, uncertainties). The application of the hot spot analysis to the linear power of pellets and the temperature rise in cooling channels is demonstrated with respect to the test zone of KNK II. Basic values, such as probability of no hot spots, hot spot potential, expected hot spot diagram and cumulative distribution function of hot spots, are discussed. It is shown, that the risk of hot channels can be dispersed equally over all subassemblies by an adequate choice of the nominal temperature distribution in the core

  7. Noninferiority of glucose-6-phosphate dehydrogenase deficiency diagnosis by a point-of-care rapid test vs the laboratory fluorescent spot test demonstrated by copper inhibition in normal human red blood cells.

    Science.gov (United States)

    Baird, J Kevin; Dewi, Mewahyu; Subekti, Decy; Elyazar, Iqbal; Satyagraha, Ari W

    2015-06-01

    Tens of millions of patients diagnosed with vivax malaria cannot safely receive primaquine therapy against repeated attacks caused by activation of dormant liver stages called hypnozoites. Most of these patients lack access to screening for glucose-6-phosphate dehydrogenase (G6PD) deficiency, a highly prevalent disorder causing serious acute hemolytic anemia with primaquine therapy. We optimized CuCl inhibition of G6PD in normal red blood cells (RBCs) to assess G6PD diagnostic technologies suited to point of care in the impoverished rural tropics. The most widely applied technology for G6PD screening-the fluorescent spot test (FST)-is impractical in that setting. We evaluated a new point-of-care G6PD screening kit (CareStart G6PD, CSG) against FST using graded CuCl treatments to simulate variable hemizygous states, and varying proportions of CuCl-treated RBC suspensions to simulate variable heterozygous states of G6PD deficiency. In experiments double-blinded to CuCl treatment, technicians reading FST and CSG test (n = 269) classified results as positive or negative for deficiency. At G6PD activity ≤40% of normal (n = 112), CSG test was not inferior to FST in detecting G6PD deficiency (P = 0.003), with 96% vs 90% (P = 0.19) sensitivity and 75% and 87% (P = 0.01) specificity, respectively. The CSG test costs less, requires no specialized equipment, laboratory skills, or cold chain for successful application, and performs as well as the FST standard of care for G6PD screening. Such a device may vastly expand access to primaquine therapy and aid in mitigating the very substantial burden of morbidity and mortality imposed by the hypnozoite reservoir of vivax malaria. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. KIT safety management. Annual report 2012

    International Nuclear Information System (INIS)

    Frank, Gerhard

    2013-01-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for - licensing procedures, - industrial safety organization, - control of environmental protection measures, - planning and implementation of emergency preparedness and response, - operation of radiological laboratories and measurement stations, - extensive radiation protection support and the - the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its industrial safety management is certified by the VBG as ''AMS-Arbeitsschutz mit System'' and, hence, fulfills the requirements of NLF / ISO-OSH 2001. KSM laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2012. Status figures in principle reflect the status at the end of the year 2012. The processes described cover the areas of competence of KSM.

  9. A novel kit for rapid detection of Vibrio cholerae O1.

    OpenAIRE

    Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R

    1994-01-01

    We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bact...

  10. A New Method to Stabilize c-kit Expression in Reparative Cardiac Mesenchymal Cells

    Directory of Open Access Journals (Sweden)

    Marcin Wysoczynski

    2016-08-01

    Full Text Available Cell therapy improves cardiac function. Few cells have been investigated more extensively or consistently shown to be more effective than c-kit sorted cells; however, c-kit expression is easily lost during passage. Here, our primary goal was to develop an improved method to isolate c-kitpos cells and maintain c-kit expression after passaging. Cardiac mesenchymal cells (CMCs from wild-type mice were selected by polystyrene adherence properties. CMCs adhering within the first hours are referred to as rapidly adherent (RA; CMCs adhering subsequently are dubbed slowly adherent (SA. Both RA and SA CMCs were c-kit sorted. SA CMCs maintained significantly higher c-kit expression than RA cells; SA CMCs also had higher expression endothelial markers. We subsequently tested the relative efficacy of SA versus RA CMCs in the setting of post-infarct adoptive transfer. Two days after coronary occlusion, vehicle, RA CMCs, or SA CMCs were delivered percutaneously with echocardiographic guidance. SA CMCs, but not RA CMCs, significantly improved cardiac function compared to vehicle treatment. Although the mechanism remains to be elucidated, the more pronounced endothelial phenotype of the SA CMCs coupled with the finding of increased vascular density suggest a potential pro-vasculogenic action. This new method of isolating CMCs better preserves c-kit expression during passage. SA CMCs, but not RA CMCs, were effective in reducing cardiac dysfunction. Although c-kit expression was maintained, it is unclear whether maintenance of c-kit expression per se was responsible for improved function, or whether the differential adherence property itself confers a reparative phenotype independently of c-kit.

  11. Vitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.

    Science.gov (United States)

    Greibe, Eva; Nexo, Ebba

    2011-11-01

    Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.

  12. c-KIT positive schistosomal urinary bladder carcinoma are frequent but lack KIT gene mutations.

    Science.gov (United States)

    Shams, Tahany M; Metawea, Mokhtar; Salim, Elsayed I

    2013-01-01

    Urinary bladder squamous cell carcinoma (SCC), one of the most common neoplasms in Egypt, is attributed to chronic urinary infection with Schistosoma haematobium (Schistosomiasis). The proto-oncogene c-KIT, encoding a tyrosine kinase receptor and implicated in the development of a number of human malignancies, has not been studied so far in schistosomal urinary bladder SCCs. We therefore determined immunohistochemical (IHC) expression of c-KIT in paraffin sections from 120 radical cystectomies of SCCs originally obtained from the Pathology Department of Suez Canal University (Ismailia, Egypt). Each slide was evaluated for staining intensity where the staining extent of >10% of cells was considered positive. c-KIT overexpression was detected in 78.3% (94/120) of the patients, the staining extents in the tumor cells were 11-50% and >50% in 40 (42.6%) and 54 (57.4%) respectively. The positive cases had 14.9%, 63.8%, 21.3% as weak, moderate and strong intensity respectively. Patients with positive bilharzial ova had significantly higher c-KIT expression than patients without (95.2% vs. 38.9%, P=0.000). Mutation analysis of exons 9-13 was negative in thirty KIT positive cases. The high rate of positivity in SBSCC was one of the striking findings; However, CD117 may be a potential target for site specific immunotherapy to improve the outcome of this tumor.

  13. Preparation of kits for 99Tcm radiopharmaceuticals

    International Nuclear Information System (INIS)

    1992-05-01

    This publication details preparation under Good Manufacturing Practices (GMP) of thirteen widely used 99 Tc m radiopharmaceuticals and their quality assurance practices. The objective of this document is to present to those who intend to launch a kit preparation programme a set of preparation procedures and other relevant information gathered during kit production over a period of more than a decade, to serve as a good starting point. The manuals and monographs included in the document are based on the experience gained in two major centres. The publication of this material is intended to give a typical example, and not the only possible procedure for preparing the kits. Following the essentials of these kit preparation procedures, it is always possible to make alterations to the composition of the kits. The kits described here concern widely used 99 Tc m radiopharmaceuticals which do not require a Single Photon Emission Computed Tomography (SPECT) camera. These examples of the ''first generation'' of kits are not very intricate to prepare. Although it is advisable to have only one agent for a given intended use, a few agents for each purpose, e.g. EHDP and MDP for bone imagining, have been included in the document so that the reader can have some flexibility in selecting a particular kit. 24 refs, 2 figs

  14. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  15. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 μU/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 μU/ml vs 4.1 - 12.3 μU/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.)

  16. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-10-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 ..mu..U/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 ..mu..U/ml vs 4.1 - 12.3 ..mu..U/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.).

  17. Hematopoietic Kit Deficiency, rather than Lack of Mast Cells, Protects Mice from Obesity and Insulin Resistance.

    Science.gov (United States)

    Gutierrez, Dario A; Muralidhar, Sathya; Feyerabend, Thorsten B; Herzig, Stephan; Rodewald, Hans-Reimer

    2015-05-05

    Obesity, insulin resistance, and related pathologies are associated with immune-mediated chronic inflammation. Kit mutant mice are protected from diet-induced obesity and associated co-morbidities, and this phenotype has previously been attributed to their lack of mast cells. We performed a comprehensive metabolic analysis of Kit-dependent Kit(W/Wv) and Kit-independent Cpa3(Cre/+) mast-cell-deficient mouse strains, employing diet-induced or genetic (Lep(Ob/Ob) background) models of obesity. Our results show that mast cell deficiency, in the absence of Kit mutations, plays no role in the regulation of weight gain or insulin resistance. Moreover, we provide evidence that the metabolic phenotype observed in Kit mutant mice, while independent of mast cells, is immune regulated. Our data underscore the value of definitive mast cell deficiency models to conclusively test the involvement of this enigmatic cell in immune-mediated pathologies and identify Kit as a key hematopoietic factor in the pathogenesis of metabolic syndrome. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Preparation of phase I of clinical testing of kit for bleomycin labelling with 57Co

    International Nuclear Information System (INIS)

    Brousil, J.; Svihovcova, P.; Seblova, J.; Raban, P.

    1986-01-01

    Experience is described gained in preclinical trials with a kit for bleomycin labelling with 57 Co, of original manufacture. The 57 Co-labelled bleomycin shows a positive tumor imaging potential. As against other labelled bleomycins described in the literature, it best meets the requirements of imaging tumors in the highest possible number of tissues and of good differentiation of tumors from the adjacent tissues. The three-component kit uses a phosphate buffer which makes it more suitable for i.v. administration and significantly increases bleomycin stability. The kit was found to show advantages over previously described radiopharmaceuticals of this type in that that it can quickly be reconstituted immediately prior to the application and that it is significantly cheaper to use, namely 140-fold cheaper than most other similar radiopharmaceuticals. Its disadvantage, i.e., the long half-life is balanced with a short biological half-life; within 24 hours following application 80 to 90% of the applied activity was found to be excreted from the organism. The short biological half-life is also beneficial for the patient in that the radiation load of the patient is 10 times lower than in the application of 67 Ga. (L.O.)

  19. 21 CFR 868.5140 - Anesthesia conduction kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  20. Fundamental and clinical evaluation of vasoactive intestinal peptide (VIP) in pancreatitis by radioimmunoassay kit

    International Nuclear Information System (INIS)

    Uehara, Soichiro; Nakamura, Takayuki; Ihara, Kenichi; Isogawa, Shin; Hirayama, Akio

    1987-01-01

    Plasma vasoactive intestinal peptide (VIP) concentrations of normal individuals and patients with pancreatitis were studied using a VIP RIA kit. The inter-assay and intra-assay variation of this kit were between 2.1 and 9.4 %. The VIP levels increased in the acute phase of acute pancreatitis and patients with chronic pancreatitis. The VIP concentration increased during the first 30 min of glucose tolerance test, but this increase was much smaller than that in insulin. These results suggest that this kit is useful for physiologic and pathologic changes in the VIP level. (author)

  1. Low-cost indigenous radiopharmaceutical kits manufacturing capability: a successful work accomplished in Ethiopia

    International Nuclear Information System (INIS)

    Jorge, Y.; Noronha, O.P.D.

    1998-01-01

    Nuclear Medicine Unit at Black Lion Hospital is the only Nuclear Medicine service giving center in the country. We have been importing Radiopharmaceutical-kits for 10 subsequent years costly, with frequent irregularities, only limited Numbers of kits mainly for Liver, Brain, Thyroid and Kidney imagings. Most of the Nuclear Medicine (NM) diagnostic procedures were not undertaken at our unit, because of unavailability of vital Radiopharmaceutical-kits (Rp-kits) in the country since they were not manufactured in the country. In order to solve this long stranding problem of the country persistent efforts were made. The success in Rp-kits manufacturing indigenously has the advantage of disseminating the NM Technology with in the country also. With the continuous efforts made 7 Aqueous-Rp-kits were manufactured successfully in our unit viza-viz: 1) 99m Tc-s-colloid-for Liver imaging. 2) 99m Tc-DTPA-for Brain + Renal imaging. 3) 99m Tc-MDP-for Bone imaging, 4) 99m Tc-Tin (11) pyrophosphate for in-vivo R,B,C, labelling: (For the study of Blood-Pool and Myocardial Infarction), 5) 99m Tc-Tin(11) Gluconate for Brain + Kidney Static imaging. 6) 99m Tc-Tin(11) Phytate for Liver imaging. 7) 99m Tc-TBI for Myocardial perfusion study. Their physico-chemical behaving patterns were studied and the chemical and biological quality control procedures were conducted upon the indigenously produced kits at the National Drug Quality Control center and they were found to be sterile, apyrogenic and non-toxic. The efficiency of the kits was tested in many patients in our unit and found to be effective and reliable. Aqueous kits produced were observed to be as effective and reliable as their lyophilized counterparts with respect to their physico-chemical properties and biospecificity (organ specificity) but possessing short shelf lives unlike lyophilized kits. (author)

  2. A safety-critical java technology compatibility kit

    DEFF Research Database (Denmark)

    Søndergaard, Hans; Korsholm, Stephan E.; Ravn, Anders Peter

    2014-01-01

    In order to claim conformance with a given Java Specification Request (JSR), a Java implementation has to pass all tests in an associated Technology Compatibility Kit (TCK). This paper presents development of test cases and tools for the draft Safety-Critical Java (SCJ) specification. In previous...... work we have shown how the Java Modeling Language (JML) is applied to specify conformance constraints for SCJ, and how JML-related tools may assist in generating and executing tests. Here we extend this work with a layout for concrete test cases including checking of results in a simplified version...

  3. Serodiagnosis of chronic Chagas infection by using EIE-Recombinant-Chagas-Biomanguinhos kit

    Directory of Open Access Journals (Sweden)

    Gomes Yara M

    2001-01-01

    Full Text Available A kit based on an enzyme immunoassay, EIE-Recombinant-Chagas-Biomanguinhos, developed by the Oswaldo Cruz Foundation, was evaluated for the serodiagnosis of chronic Chagas disease. Evaluation was performed with 368 serum samples collected from individuals living in an endemic area for Chagas disease: 131 patients in the chronic phase with confirmed clinical, epidemiological, and serological diagnosis (indirect immunofluorescence, indirect hemagglutination or enzyme-linked immunosorbent assay and 237 nonchagasic seronegative individuals were considered negative control. The EIE-Recombinant-Chagas-Biomanguinhos kit showed high sensitivity, 100% (CI 95%: 96.4-100% and high specificity, 100% (CI 95%: 98-100%. The data obtained were in full agreement with clinical and conventional serology data. In addition, no cross-reaction was observed with sera from patients with cutaneous (n=14 and visceral (n=3 leishmaniasis. However, when these sera were tested by conventional serological assays for Chagas disease, cross-reactions were detected in 14.3% and 33.3% of the patients with cutaneous and visceral leishmaniasis, respectively. No cross-reactions were observed when sera from nonchagasic seronegative patients bearing other infectious disease (syphilis, n=8; HTLV, n=8; HCV, n=7 and HBV, n=12 were tested. In addition, sera of patients with inconclusive results for Chagas disease by conventional serology showed results in agreement with clinical evaluation, when tested by the kit. These results are relevant and indicate that the refered kit provides a safe immunodiagnosis of Chagas disease and could be used in blood bank screening.

  4. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    Science.gov (United States)

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  5. 21 CFR 864.2260 - Chromosome culture kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chromosome culture kit. 864.2260 Section 864.2260...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Cell And Tissue Culture Products § 864.2260 Chromosome culture kit. (a) Identification. A chromosome culture kit is a device containing the necessary ingredients...

  6. The challenges of lean manufacturing implementation in kitting assembly

    Science.gov (United States)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  7. 46 CFR 169.725 - First aid kit.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  8. KIT polymorphisms and mutations determine responses of neoplastic mast cells to bafetinib (INNO-406).

    Science.gov (United States)

    Peter, Barbara; Hadzijusufovic, Emir; Blatt, Katharina; Gleixner, Karoline V; Pickl, Winfried F; Thaiwong, Tuddow; Yuzbasiyan-Gurkan, Vilma; Willmann, Michael; Valent, Peter

    2010-09-01

    Advanced systemic mastocytosis (SM) is characterized by uncontrolled growth of neoplastic mast cells (MC) and drug resistance. The tyrosine kinase receptor KIT is often mutated and activated and thus contributes to malignant growth of MC. Therefore, KIT-targeting drugs are currently tested for their ability to block growth of malignant MC. We determined the effects of the multikinase inhibitor INNO-406 (bafetinib) on primary neoplastic MC, the canine mastocytoma cell line C2, the human MC leukemia cell line HMC-1.1 bearing the KIT mutant V560G, and HMC-1.2 cells harboring KIT V560G and KIT D816V. INNO-406 was found to inhibit proliferation in HMC-1.1 cells (IC(50): 30-40 nM), but not in HMC-1.2 cells or primary neoplastic cells in patients with KIT D816V-positive SM. In canines, growth-inhibitory effects of INNO-406 were seen in C2 cells (IC(50): 50-100 nM) exhibiting a KIT exon 11 internal tandem-duplication and in primary neoplastic MC harboring wild-type exon 11, whereas no effects were seen in MC exhibiting a polymorphism at amino acid 581 in exon 11. INNO-406 was found to block KIT phosphorylation and expression in HMC-1.1 cells and C2 cells, but not in HMC-1.2 cells, whereas Lyn-phosphorylation was blocked by INNO-406 in all types of MC. In neoplastic MC, the major target of INNO-406 appears to be KIT. Drug responses may depend on the presence and type of KIT mutation. In human MC, the KIT D816V mutant introduces resistance, and in canine mastocytomas, an exon 11 polymorphism may be indicative of resistance against INNO-406.

  9. Analysis of SNPs in the KIT gene of cattle with different coat colour patterns and perspectives to use these markers for breed traceability and authentication of beef and dairy products

    Directory of Open Access Journals (Sweden)

    Vincenzo Russo

    2010-04-01

    Full Text Available The identification of the breed of origin of farm animals has recently assumed particular relevance as increasing interests in marketing mono-breed labelled lines of beef and dairy products have created the need to protect them from frauds. In order to develop DNA based breed traceability and authentication protocols, the first step is the identification of breed specific markers with high discriminatory power among breeds. We analysed two single nucleotide polymorphisms identified in exon 2 (g.72779776C>T and exon 3 (g.72783182A>G of the KIT gene (a candidate gene for the spotting locus in seven cattle breeds with different coat colour patterns (Italian Holstein-Friesian, no. = 61; Italian Brown, no. = 60; Italian Simmental, no. = 78; Jersey, no. = 60; Rendena, no. = 51; Reggiana, no. = 128; and Modenese, no. = 52. The two alleles of both SNPs were detected in all analysed breeds making their use unsuitable in breed traceabilty with a deterministic approach. Italian Simmental was almost fixed for the most common alleles (g.72779776C and g.72783182A. Haplotype analysis showed that spotted breeds (Italian Holstein-Friesian and Italian Simmental had only two haplotypes with one of them ([C:A] with high frequency (~90% and ~99%, respectively. Analysis of molecular variance (AMOVA averaged over the two loci indicated that genetic variation between spotted and non-spotted groups of breeds amounted to 25.3% (P<0.05 supporting a possible involvement of the KIT gene in influencing the spotted phenotype, but probably not determining it, as we previously suggested. Pairwise Fst values indicated significant differences between almost all pair of investigated breeds. The high discriminatory power of the analysed SNPs is an important characteristic for the inclusion of these markers in SNP panels useful for breed allocation and traceability based on probabilistic approaches.

  10. 46 CFR 108.707 - First aid kit.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  11. Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood

    International Nuclear Information System (INIS)

    McGown, E.L.; Lewis, C.M.; Dong, M.H.; Sauberlich, H.E.

    1978-01-01

    Results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] were compared with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested on whole-blood samples; both yielded values significantly higher than those by microbiological assay. The frequency distributions of erythrocyte folate data differed strikingly between the two kits; the NEN method yielded a much narrower range of normal values than did either the Bio-Rad or the microbiological assay. Radioassay kits appear to be suitable diagnostic agents for serum folate, if the behavior of a particular kit is investigated thoroughly before its routine use. However, the diagnostic value of radioassays of erythrocyte folate needs to be validated

  12. Determining the feline immunodeficiency virus (FIV) status of FIV-vaccinated cats using point-of-care antibody kits.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M

    2015-10-01

    This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Stannous ion quantitation in sup(99m)Tc-radiopharmaceutical kits

    International Nuclear Information System (INIS)

    Chervu, L.R.; Vallabhajosyula, B.; Mani, J.; Chun, S.B.; Blaufox, M.D.

    1982-01-01

    A simple and inexpensive method for the estimation of stannous ion, Sn(II), in radiopharmaceutical kits is described. The method used is a potentiometric titration of Sn(II) in 1 N HCl medium, using potassium iodate as the oxidizing agent in an atmosphere of nitrogen. The apparatus includes a pH meter, a platinum electrode, and a simple titration cell. Several commonly used radiopharmaceutical kits were analyzed for their Sn(II) content using this method. These studies indicate that the procedure can be used, as a routine quantitative test for the Sn(II) content of various sup(99m)Tc-labeled radiopharmaceuticals. (orig.)

  14. Use of monoclonal immunoradiometric assays for sensitive TSH measurements: evaluation of four commercially obtainable kits

    International Nuclear Information System (INIS)

    Smitz, J.; Schiettecatte, J.; Stierteghem, A.C. van; Jonckheer, M.H.

    1987-01-01

    Four commerically available monoclonal immunoradiometric methods for the assay of TSH are tested. These four kits are: RIA-GNOST TSH code 0CPL of Behring, SUCROSEP TSH IRMA of Boots, TSH-IRMA-CT-100 of Medgenix, TSH-RIA bead II Ultrasensitive of Abbott. The accuracy, sensitivity and reproducibility of the four kits are compared. The methods are also clinically evaluated. The authors concluded that the kits of Abbott, Behring and Boots are suitable for use in the routine laboratory. 4 refs.; 4 figs.; 7 tabs

  15. LANL12-RS-108J Report on Device Modeler Testing of the Device Modeler Tool Kit. DMTK in FY14

    Energy Technology Data Exchange (ETDEWEB)

    Temple, Brian Allen [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States); Pimentel, David A. [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)

    2014-09-28

    This document covers the various testing and modifications of the Device Modeler Tool Kit (DMTK) for project LANL12-RS-108J in FY14. The testing has been comprised of different device modelers and trainees for device modeling using DMTK on the secure network for a few test problems. Most of these problems have been synthetic data problems. There has been a local secure network training drill where one of the trainees has used DMTK for real data. DMTK has also been used on a laptop for a deployed real data training drill. Once DMTK gets into the home team, it will be used for more training drills (TDs) which will contain real data in the future.

  16. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    Science.gov (United States)

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  17. Accuracy of a point-of-care ELISA test kit for predicting the presence of protective canine parvovirus and canine distemper virus antibody concentrations in dogs.

    Science.gov (United States)

    Litster, A L; Pressler, B; Volpe, A; Dubovi, E

    2012-08-01

    Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. A digital image method of spot tests for determination of copper in sugar cane spirits

    Science.gov (United States)

    Pessoa, Kenia Dias; Suarez, Willian Toito; dos Reis, Marina Ferreira; de Oliveira Krambeck Franco, Mathews; Moreira, Renata Pereira Lopes; dos Santos, Vagner Bezerra

    2017-10-01

    In this work the development and validation of analytical methodology for determination of copper in sugarcane spirit samples is carried out. The digital image based (DIB) method was applied along with spot test from the colorimetric reaction employing the RGB color model. For the determination of copper concentration, it was used the cuprizone - a bidentate organic reagent - which forms with copper a blue chelate in an alkaline medium. A linear calibration curve over the concentration range from 0.75 to 5.00 mg L- 1 (r2 = 0.9988) was obtained and limits of detection and quantification of 0.078 mg L- 1 and 0.26 mg L- 1 were acquired, respectively. For the accuracy studies, recovery percentages ranged from 98 to 104% were obtained. The comparison of cooper concentration results in sugar cane spirits using the DIB method and Flame Atomic Absorption Spectrometry as reference method showed no significant differences between both methods, which were performed using the paired t-test in 95% of confidence level. Thus, the spot test method associated with DIB allows the use of devices as digital cameras and smartphones to evaluate colorimetric reaction with low waste generation, practicality, quickness, accuracy, precision, high portability and low-cost.

  19. Testing the nature of the supermassive black hole candidate in SgrA* with light curves and images of hot spots

    International Nuclear Information System (INIS)

    Li, Zilong; Kong, Lingyao; Bambi, Cosimo

    2014-01-01

    General relativity makes clear predictions about the spacetime geometry around black holes. In the near future, new facilities will have the capability to explore the metric around SgrA*, the supermassive black hole candidate at the center of our Galaxy, and to open a new window to test the Kerr black hole hypothesis. In this paper, we compute light curves and images associated with compact emission regions (hot spots) orbiting around Kerr and non-Kerr black holes. We study how the analysis of the properties of the radiation emitted by a hot spot can be used to test the Kerr nature of SgrA*. We find that the sole observation of the hot spot light curve can at most constrain a combination of the black hole spin and of possible deviations from the Kerr solution. This happens because the same orbital frequency around a Kerr black hole can be found for a non-Kerr object with a different spin parameter. Second order corrections in the light curve due to the background geometry are typically too small to be identified. While the observation of the hot spot centroid track can potentially bound possible deviations from the Kerr solution, that is out of reach for the near future for the Very Large Telescope Interferometer instrument GRAVITY. The Kerr black hole hypothesis could really be tested in the case of the discovery of a radio pulsar in a compact orbit around SgrA*. Radio observations of such a pulsar would provide precise estimates of the mass and the spin of SgrA*, and the combination of these measurements (probing the weak field) with the hot spot light curve information (probing the strong field) may constrain/find possible deviations from the Kerr solution with quite good precision.

  20. Testing the nature of the supermassive black hole candidate in SgrA* with light curves and images of hot spots

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zilong; Kong, Lingyao; Bambi, Cosimo [Center for Field Theory and Particle Physics and Department of Physics, Fudan University, 200433 Shanghai (China)

    2014-06-01

    General relativity makes clear predictions about the spacetime geometry around black holes. In the near future, new facilities will have the capability to explore the metric around SgrA*, the supermassive black hole candidate at the center of our Galaxy, and to open a new window to test the Kerr black hole hypothesis. In this paper, we compute light curves and images associated with compact emission regions (hot spots) orbiting around Kerr and non-Kerr black holes. We study how the analysis of the properties of the radiation emitted by a hot spot can be used to test the Kerr nature of SgrA*. We find that the sole observation of the hot spot light curve can at most constrain a combination of the black hole spin and of possible deviations from the Kerr solution. This happens because the same orbital frequency around a Kerr black hole can be found for a non-Kerr object with a different spin parameter. Second order corrections in the light curve due to the background geometry are typically too small to be identified. While the observation of the hot spot centroid track can potentially bound possible deviations from the Kerr solution, that is out of reach for the near future for the Very Large Telescope Interferometer instrument GRAVITY. The Kerr black hole hypothesis could really be tested in the case of the discovery of a radio pulsar in a compact orbit around SgrA*. Radio observations of such a pulsar would provide precise estimates of the mass and the spin of SgrA*, and the combination of these measurements (probing the weak field) with the hot spot light curve information (probing the strong field) may constrain/find possible deviations from the Kerr solution with quite good precision.

  1. Dip-strip method for monitoring environmental contamination of aflatoxin in food and feed: use of a portable aflatoxin detection kit.

    Science.gov (United States)

    Sashidhar, R B

    1993-10-01

    Aflatoxin contamination of food and feed have gained global significance due to its deleterious effect on human and animal health and its importance in the international trade. The potential of aflatoxin as a carcinogen, mutagen, teratogen, and immunosuppressive agent is well documented. The problem of aflatoxin contamination of food and feed has led to the enactment of various legislation. However, meaningful strategies for implementation of this legislation is limited by nonavailability of simple, cost-effective method for screening and detection of aflatoxin under field conditions. Keeping in mind the analytical constraints in developing countries, a simple-to-operate, rapid, reliable, and cost-effective portable aflatoxin detection kit has been developed. The important components of the kit include a hand-held UV lamp (365 nm, 4 W output), a solvent blender (12,000 rpm) for toxin extraction, and adsorbent-coated dip-strips (polyester film) for detecting and quantifying aflatoxin. Analysis of variance indicates that there were no significant differences between various batches of dip-strips (p > 0.05). The minimum detection limit for aflatoxin B1 was 10 ppb per spot. The kit may find wide application as a research tool in public health laboratories, environmental monitoring agencies, and in the poultry industry.

  2. Rocky Mountain Spotted Fever: Statistics and Epidemiology

    Science.gov (United States)

    ... Search Form Controls Cancel Submit Search the CDC Rocky Mountain Spotted Fever (RMSF) Note: Javascript is disabled or is not ... message, please visit this page: About CDC.gov . Rocky Mountain Spotted Fever (RMSF) Transmission Signs and Symptoms Diagnosis and Testing ...

  3. Spot Variance Path Estimation and its Application to High Frequency Jump Testing

    NARCIS (Netherlands)

    Bos, C.S.; Janus, P.; Koopman, S.J.

    2012-01-01

    This paper considers spot variance path estimation from datasets of intraday high-frequency asset prices in the presence of diurnal variance patterns, jumps, leverage effects, and microstructure noise. We rely on parametric and nonparametric methods. The estimated spot variance path can be used to

  4. Kit with track detectors aiming at didactic

    International Nuclear Information System (INIS)

    Cesar, M.F.; Koskinas, M.F.

    1988-01-01

    The kit intends to improve the possibilities in performing experiments of Nuclear Physics in Modern Physics Laboratories of Physics Course introducing the solid state nuclear track detectors. In these materials the passage of heavily ionizing nuclear particles creates paths (tracks) that may be revealed and made visible in an optical microscope. By the help of the kit several experiments and/or demonstrations may be performed. The kit contains solid state nuclear track detectors unirradiated and irradiated, irradiated etched and uneteched sheets; an alpha source of 241 Am and an instrution text with photomicrographs. To use the kit the laboratory must have an ordinary optical microscope. (author) [pt

  5. Increasing Flight Software Reuse with OpenSatKit

    Science.gov (United States)

    McComas, David C.

    2018-01-01

    In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospace's command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for users to extend the FSW functionality to meet their

  6. A novel kit for rapid detection of Vibrio cholerae O1.

    Science.gov (United States)

    Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R

    1994-01-01

    We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bacterial strains, including both O1 and non-O1 serotypes of V. cholerae isolated from samples collected from a variety of geographical regions, were tested, and positive reactions were observed only with V. cholerae O1. Also, results of a field trial in Bangladesh, employing Cholera SMART, showed 100% specificity and 96% sensitivity compared with conventional culture methods. Another field trial, in Mexico, showed that Cholera SMART was 100% in agreement with a recently described coagglutination test when 108 stool specimens were tested.

  7. Liver spots

    Science.gov (United States)

    ... skin changes - liver spots; Senile or solar lentigines; Skin spots - aging; Age spots ... Liver spots are changes in skin color that occur in older skin. The coloring may be due to aging, exposure to the sun ...

  8. Iodine-125--digoxin radioimmunoassay: comparison of commercial kits

    International Nuclear Information System (INIS)

    Battaglia, D.J.; Cianci, M.L.

    1976-01-01

    Iodine-125-digoxin radioimmunoassay kits available from Abbott Diagnostics (AD), Dade Division (D), Schwarz/Mann (SM), and Clinical Assays (CA) were evaluated with respect to assay quality. The kit accuracies did not differ significantly at 2.0 ng/ml and the interassay coefficients of variation ranged from 9 percent (AD) to 21.4 percent (CA). The accuracy for all kits above 4 ng/ml is questionable, and since serum-dilution values correlated well with undiluted serum values, the dilution method of dose quantitation is preferable for levels above 4 ng/ml. Although all the kits were adequate for evaluating digoxin at the 2 ng/ml level, the Abbott kit seems to be of slightly better quality

  9. Preparation of albumin radioimmunoassay kit

    International Nuclear Information System (INIS)

    Chen Suoshu; Wang Yanzhen; Wang Zhenshan

    1990-01-01

    This paper presents the preparation of Albumin (Alb) radioimmunoassay kit and its preliminary clinical application. The kit is mainly applied to the measurement of Alb concentration in human urine, adopting second antibody-PEG method. The measurement range is (1-50 μg/ml). The curve obtained with a serially diluted urine sample of high Alb concentration was a straight line. Recovery, detectability, intra- and inter-batch variation coefficients were 95.7%-103.6%, 0.1 μg/ml, 5.8% and 6.4% respectively. The kit was tried out clinically for measuring Alb in urine samples in about 1200 normal individuals and 600 various patients of related renal diseases. The preliminary clinical results show that Alb RIA is conducive to the early diagnosis of kidney function abnormalities

  10. Existence of c-Kit negative cells with ultrastructural features of interstitial cells of Cajal in the subserosal layer of the W/Wv mutant mouse colon.

    Science.gov (United States)

    Tamada, Hiromi; Kiyama, Hiroshi

    2015-01-01

    Interstitial cells of Cajal (ICC) are mesenchymal cells that are distributed along the gastrointestinal tract and function as pacemaker cells or intermediary cells between nerves and smooth muscle cells. ICC express a receptor tyrosine kinase c-Kit, which is an established marker for ICC. The c-kit gene is allelic with the murine white-spotting locus (W), and some ICC subsets were reported to be missing in heterozygous mutant W/Wv mice carrying W and Wv mutated alleles. In this study, the characterization of interstitial cells in the subserosal layer of W/Wv mice was analyzed by immunohistochemistry and electron microscopy. In the proximal and distal colon of W/Wv mutant mice, no c-Kit-positive cells were detected in the subserosal layer by immunohistochemistry. By electron microscopy, the interstitial cells, which were characterized by the existence of caveolae, abundant mitochondria and gap junctions, were observed in the W/Wv mutant colon.The morphological characteristics were comparable to those of the multipolar c-Kit positive ICC seen in the subserosa of proximal and distal colon of wild-type mice. Fibroblasts were also located in the same layers,but the morphology of the fibroblasts was distinguishable from that of ICC in wild type mice or of ICC-like cells in W/Wv mutant mice. Collectively, it is concluded that c-Kit-negative interstitial cells showing a typical ICC ultrastructure exist in the proximal and distal colon of W/Wv mutant mice.

  11. Optimization and Validation of kit of detection Antibiotics on Honey

    International Nuclear Information System (INIS)

    Hamza, Malek

    2013-01-01

    According to the Codex Alimentarius and the European Commission Directive each food has a maximum residual antibiotic (MRLs) however, for honey is still no limit set. Among the main methods that guarantee the detection of antibiotic residues include the Premi Test which is a qualitative method for the detection of antibiotics in honey, but it remains a non-specific method for this matrix and long enough (three hours of incubation). Through this work, we were able to develop and optimize a new kit called Honey test. This kit is able to detect the presence of antibiotic residues in honey by a bacterial strain radio-resistant called D.ra. The duration of treatment is only 30 minutes, requiring incubation at 37 Degree C and treatment with UV at 366 nm. This work will be the subject of a national patent.

  12. Identification of the Thickness of Nugget on Worksheet Spot Welding Using Non Destructive Test (NDT) - Effect of Pressure

    Science.gov (United States)

    Sifa, A.; Baskoro, A. S.; Sugeng, S.; Badruzzaman, B.; Endramawan, T.

    2018-02-01

    Resistance Spot Welding (RSW) is a process of connecting between two worksheet with thermomechanical loading process, RSW is widely used in automotive industry, the quality of splicing spot welding is influenced by several factors. One of the factors at the time of the welding process is pressure. The quality of welding on the nuggets can be determined by undertaking non-destructive testing by using Non Destructive Test (NDT) - Ultrasonic Test. In the NDT test is done by detecting the thickness of the nugget area, the purpose of research conducted to determine the effect of pressure to welding quality with Nugget thickness gauge measurement with Non Destructive Test method and manual measurement with micrometer, Experimental welding process by entering the welding parameters that have been specified and pressure variables 1 -5 bars on the worksheet thickness of 1 mm. The results of testing with NDT show there is addition of thickness in nugget superiority after compare with measurement result of thickness of nugget with micrometer which slightly experience thickness in nugget area, this indicates that the welding results have a connection between worksheet 1 and worksheet 2.

  13. Development of Safety Kit for Industrial Radiography Application

    International Nuclear Information System (INIS)

    Mohd Noorul Ikhsan Ahmad; Amry Amin Abas

    2011-01-01

    A safety kit for industrial radiography has been developed. The safety kit that consist of a set of technical rod and various size of base that can be used in radiograph of pipe with diameter between half and one and half inch with utilization of collimator. With the kit, radiographers will not having anymore problem to use collimator in their work. The paper discuss about the technical measures of the safety kit and the importance of introducing it to the industry. (author)

  14. Trükitööstuste TOP 50

    Index Scriptorium Estoniae

    2002-01-01

    Trükitööstuste TOP 50. Käibe TOP 30. Käibe kasum TOP 30. Kasvu TOP 30. Kasumi kasvu TOP 30. Rentaabluse TOP. Varade tootlikkuse TOP. Trükitööstusettevõtete üldandmed. Trükitööstusettevõtete finantsandmed

  15. C-kit-targeted imaging of gastrointestinal stromal tumor using radiolabeled anti-c-kit monoclonal antibody in a mouse tumor model

    International Nuclear Information System (INIS)

    Sogawa, Chizuru; Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Yoshida, Chisato; Odaka, Kenichi; Uehara, Tomoya; Arano, Yasushi; Koizumi, Mitsuru; Saga, Tsuneo

    2010-01-01

    Introduction: Gastrointestinal stromal tumor (GIST) is the most common mesenchymal tumor arising from the gastrointestinal tract and highly expresses mutated c-kit. We aimed to develop a specific and sensitive method for detecting GISTs using radiolabeled anti-c-kit monoclonal antibody. Methods: A mutated c-kit-expressing cell clone was established by transfecting an expressing vector of mutated c-kit gene into HEK293 human embryonic kidney cells. The tumors were developed by inoculating c-kit-expressing cells into nude mice. 125 I- and 111 In-labeled anti-c-kit antibodies (12A8 and 41A11) were evaluated in vitro by cell binding, competitive inhibition and cellular internalization assays, and in vivo by biodistribution and imaging studies in tumor-bearing mice. Results: Both 125 I- and 111 In-labeled antibodies showed specific binding with c-kit-expressing cells with high affinity (dissociation constants = 2.2-7.1x10 9 M -1 ). Internalization assay showed that 125 I-labeled antibodies were rapidly internalized and dehalogenated, with the release of 125 I from the cells, resulting in reduction of cell-associated radioactivity with time. In contrast, 111 In-labeled antibody was internalized but did not result in the reduced radioactivity associated with tumor cells. Reflecting this phenomenon, the in vivo tumor uptake of 125 I-labeled antibody was low on Day 1, further decreasing with time, while tumor uptake of 111 In-labeled antibody was high on Day 1, further increasing with time. The xenografted tumor was clearly visualized by scintigraphy after injection of 111 In-labeled antibody. Conclusion: The anti-c-kit monoclonal antibody labeled with a metal radionuclide would be promising for c-kit-targeted imaging of GISTs.

  16. Discovery of amido-benzisoxazoles as potent c-Kit inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Roxanne K.; Rumfelt, Shannon; Chen, Ning; Zhang, Dawei; Tasker, Andrew S.; Bürli, Roland; Hungate, Randall; Yu, Violeta; Nguyen, Yen; Whittington, Douglas A.; Meagher, Kristin L.; Plant, Matthew; Tudor, Yanyan; Schrag, Michael; Xu, Yang; Ng, Gordon Y.; Hu, Essa (Amgen)

    2010-01-12

    Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.

  17. Evaluation of the InnoTyper® 21 genotyping kit in multi-ethnic populations

    DEFF Research Database (Denmark)

    Ristow, Peter Gustav; Barnes, Nicole; Murphy, Gina Pineda

    2017-01-01

    We report the findings of the evaluation of the InnoTyper® 21 genotyping kit for the use of human identification (HID) and paternity testing in South Africa. This novel forensic kit evaluates 20 retrotransposable elements (AC4027, MLS26, ALU79712, NBC216, NBC106, RG148, NBC13, AC2265, MLS09, AC11...

  18. Development of positron emission tomography probe of 64Cu-labeled anti-C-kit 12A8 Fab to measure protooncogene C-kit expression

    International Nuclear Information System (INIS)

    Yoshida, Chisato; Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Sogawa, Chizuru; Inubushi, Masayuki; Uehara, Tomoya; Fukumura, Toshimitsu; Koizumi, Mitsuru; Arano, Yasushi; Saga, Tsuneo

    2011-01-01

    Introduction: C-kit is an important diagnostic and therapeutic target molecule for several malignancies, and c-kit-targeted drugs have been used clinically. Because abundant c-kit expression in tumors is a prerequisite for successful c-kit-targeted therapy, imaging of c-kit expression is expected to play a pivotal role in the therapeutic decision for each patient. We evaluated 64 Cu-labeled Fab of anti-c-kit antibody 12A8 as a positron emission tomography (PET) imaging probe. Methods: 111 In- or 125 I-Labeled 12A8 Fab was evaluated in vitro by cell binding, competitive inhibition and cellular internalization assays, and in vivo by biodistribution in mice bearing c-kit-expressing and -non-expressing tumors. Next, Fab fragment was labeled with the positron emitter 64 Cu and evaluated by PET. Results: Radiolabeled 12A8 Fab showed specific binding to c-kit-expressing cells with high affinity and internalized into cells after binding to c-kit on cell surface. Although tumor accumulation of [ 111 In]Fab was lower than that of [ 111 In]IgG, the faster blood clearance of [ 111 In]Fab provided higher tumor-to-blood ratio at 6 h postinjection onwards. Blood clearance of 64 Cu-labeled 12A8 Fab was slower than that of [ 111 In]Fab, but PET using [ 64 Cu]Fab clearly visualized the tumor at 6 h postinjection onwards. Conclusion: The 64 Cu-labeled 12A8 Fab could be used for c-kit-specific PET imaging and might help in selecting appropriate patients for c-kit-targeted treatments.

  19. HIV Testing Practices and Interest in Self-Testing Options among Young, Black Men Who Have Sex with Men in North Carolina

    Science.gov (United States)

    HURT, Christopher B.; SONI, Karina; MILLER, William C.; HIGHTOW-WEIDMAN, Lisa B.

    2016-01-01

    Background Young, Black men who have sex with men (YBMSM) experience disproportionately high HIV incidence in the United States. Relative to other at-risk populations, less is known about their HIV testing behaviors and preferences regarding self-testing. Methods We used an online survey to investigate testing practices and interest in self-testing among HIV-uninfected, 18–30 year-old YBMSM in North Carolina. Results From July 2014 – March 2015, 212 completed the survey; median age was 24 years. Among 175 (83%) who had ever been tested, 160 (91%) reported testing in the prior year, 124 (71%) tested at least every 6 months, and 71 (40%) tested at least quarterly. About three-quarters (77%; n=164) were aware of HIV self-testing; 35 (17%) had ever purchased rapid (n=27) or dried blood spot-based (n=14) kits. Participants aware of kits had greater intention to test in the next 6 months; were more likely to have income for basic necessities and to ask sex partners about HIV status; and were less likely to have a main sex partner or to have had transactional sex. Among 142 participants at least somewhat likely to self-test in the future, convenience (35%), privacy (23%), and rapid result delivery (18%) were the principal motivators. Conclusions Eight of every ten YBMSM have ever been tested for HIV, but inter-test intervals remain unacceptably long for many. Awareness of and interest in self-testing is substantial, but few have used this method. Expanded use of self-tests could help increase the frequency of HIV testing in this epidemiologically important population. PMID:27513387

  20. Escherichia coli and virus isolated from ''sticky kits''

    DEFF Research Database (Denmark)

    Jørgensen, M.; Scheutz, F.; Strandbygaard, Bertel

    1996-01-01

    A total of 121 Escherichia coli strains isolated from 3-week-old mink kits were serotyped and examined for virulence factors. 56 strains were isolated from healthy kits while 65 were from ''sticky kits''. Among these, 34 different serotypes were detected. No difference in serotypes or the presenc...

  1. C-kit expression in canine mucosal melanomas.

    Science.gov (United States)

    Newman, S J; Jankovsky, J M; Rohrbach, B W; LeBlanc, A K

    2012-09-01

    The c-kit receptor is responsible for transmission of promigration signals to melanocytes; its downregulation may be involved in malignant progression of human melanocytic neoplasms. Expression of this receptor has not been examined in normal or neoplastic melanocytes from dogs. In this study, 14 benign dermal and 61 malignant mucosal melanocytic tumors were examined for c-kit (KIT) expression. Sites of the mucosal melanomas were gingiva (not further specified; n = 30), buccal gingiva (n = 6), soft palate (n = 4), hard palate (n = 5), tongue (n = 7), lip (n = 6), and conjunctiva (n = 3). Melan A was expressed in all 14 dermal melanocytomas and in 59 of 61 (96.7%) tumors from oral or conjunctival mucosa, confirming melanocytic origin. C-kit receptor expression was strong and diffuse throughout the cytoplasm in all 14 dermal melanocytomas and was identified in basilar mucosal melanocytes over submucosal neoplasms (27 of 61, 44.3%), junctional (neoplastic) melanocytes (17 of 61, 27.9%), and, less commonly, neoplastic melanocytes of the subepithelial tumors (6 of 61, 9.8%). KIT expression anywhere within the resected melanomas correlated with significantly longer survival. These results suggest that c-kit receptor expression may be altered in canine melanomas and may have potential as a prognostic indicator for mucosal melanomas.

  2. SpotADAPT

    DEFF Research Database (Denmark)

    Kaulakiene, Dalia; Thomsen, Christian; Pedersen, Torben Bach

    2015-01-01

    by Amazon Web Services (AWS). The users aiming for the spot market are presented with many instance types placed in multiple datacenters in the world, and thus it is difficult to choose the optimal deployment. In this paper, we propose the framework SpotADAPT (Spot-Aware (re-)Deployment of Analytical...... of typical analytical workloads and real spot price traces. SpotADAPT's suggested deployments are comparable to the theoretically optimal ones, and in particular, it shows good cost benefits for the budget optimization -- on average SpotADAPT is at most 0.3% more expensive than the theoretically optimal...

  3. Scientific evaluation of an intra-curricular educational kit to foster inquiry-based learning (IBL)

    Science.gov (United States)

    Debaes, Nathalie; Cords, Nina; Prasad, Amrita; Fischer, Robert; Euler, Manfred; Thienpont, Hugo

    2014-07-01

    Society becomes increasingly dependent on photonics technologies; however there is an alarming lack of technological awareness among secondary school students. They associate photonics with experiments and components in the class room that seem to bear little relevance to their daily life. The Rocard Report [5] highlights the need for fostering students' scientific skills and technological awareness and identifies inquiry based learning (IBL) as a means to achieve this. Students need to actively do science rather than be silent spectators. The `Photonics Explorer' kit was developed as an EU funded project to equip teachers, free-of-charge, with educational material designed to excite, engage and educate European secondary school students using guided inquiry based learning techniques. Students put together their own experiments using up-to-date versatile components, critically interpret results and relate the conclusions to relevant applications in their daily life. They work hands-on with the material, thus developing and honing their scientific and analytical skills that are otherwise latent in a typical class room situation. A qualitative and quantitative study of the impact of the kit in the classroom was undertaken with 50 kits tested in 7 EU countries with over 1500 students in the local language. This paper reports on the results of the EU wide field tests that show the positive impact of the kit in raising the self-efficacy, scientific skills and interest in science among students and the effectiveness of the kit in implementing IBL strategies in classrooms across EU.

  4. c-DNA of HIV-1 detection on spot of Buffy-Coat of leukocytes (DBCS

    Directory of Open Access Journals (Sweden)

    Marco Rossi de Gasperis

    2010-03-01

    Full Text Available Introduction:The elective way for the diagnosis of HIV-1-infection in the window period and in children under the age of 16-18 months is to search virus integrated in leukocytes. Aim of the study was to assess the sensitivity and specificity of extraction from Buffy-Dried Coat Spot (DBCS in leukocyte to detect c-DNA with nested-PCR in HIV-1-infected individuals compared to Dried Blood Spot (DBS both extracted by automated instrument EZ1 (QIAGEN, Hilden, Germany. Both DBCS and both DBS were compared with those tests from whole blood by conventional DNA-extraction Methods: Five ml of whole blood from 50 HIV-infected individuals were collected. 40 μl of each sample were spotted on “FTA ELUTE Micro Card” (Whatman, Inc., Clifton, NJ, 200 μl were extracted according to the manual procedure (QIAGEN “QIAamp DNA minikit and the remaining sample was incubated at 37 °C for 120 minutes. Plasma was centrifuged at 1000 rcf/1g for 10 minutes at room temperature. Forty μl of the obtained buffy-coat was spotted. Both DBCS and both DBS were dried at room temperature for 24 hours.Two of 5 punch from each spot were extracted with TISSUE DNA kit (Biorobot EZ1 DSP “Qiagen” and eluted in 50 μl of buffer.The recovery of genomic DNA was measured amplifying the ß-globin gene by Real-Time “SybrGreen I”.The DNA was amplified for the “pol” gene of HIV-1 by nested PCR and revealed in “SYBR-green I”. Eight HIV-antibody-negative samples were used as internal control. Results:The experimental protocol adopted for the DBCS showed high sensitivity and specificity.The extracted DNA from DBS and DBCS was characterized by excellent quality and without any inhibitory agents. The amount of proviral DNA extracted from DBCS is similar to that obtained by conventional extraction, while the DBS test was significantly less sensitive. Conclusion:These preliminary data suggest that the amount of c-DNA obtained with DBS technique is often not enough for the

  5. Assessment of RFID Read Accuracy for ISS Water Kit

    Science.gov (United States)

    Chu, Andrew

    2011-01-01

    The Space Life Sciences Directorate/Medical Informatics and Health Care Systems Branch (SD4) is assessing the benefits Radio Frequency Identification (RFID) technology for tracking items flown onboard the International Space Station (ISS). As an initial study, the Avionic Systems Division Electromagnetic Systems Branch (EV4) is collaborating with SD4 to affix RFID tags to a water kit supplied by SD4 and studying the read success rate of the tagged items. The tagged water kit inside a Cargo Transfer Bag (CTB) was inventoried using three different RFID technologies, including the Johnson Space Center Building 14 Wireless Habitat Test Bed RFID portal, an RFID hand-held reader being targeted for use on board the ISS, and an RFID enclosure designed and prototyped by EV4.

  6. Formulation of 68Ga BAPEN kit for myocardial positron emission tomography imaging and biodistribution study

    International Nuclear Information System (INIS)

    Yang, Bo Yeun; Jeong, Jae Min; Kim, Young Joo; Choi, Jae Yeon; Lee, Yun-Sang; Lee, Dong Soo

    2010-01-01

    Introduction: Tris(4,6-dimethoxysalicylaldimine)-N,N'-bis(3-aminopropyl) -N,N'-ethylenediamine (BAPEN), a tris(salicylaldimine) derivative, is a heart positron emission tomography (PET) agent when labeled with 68 Ga. However, its labeling requires complicated and time-consuming procedures. In this study, the authors formulated a new BAPEN kit for convenient 68 Ga labeling. Methods: BAPEN (0.25 mg) kits were prepared by dispensing its solution in 1 M sodium acetate buffer (pH 5.5) into sterile vials and lyophilization. The prepared kits were labeled with generator-eluted 68 Ga in 0.1 N HCl. Stability in human serum was tested. Expiration date was determined by accelerated testing according to US Food and Drug Administration guidelines. A Biodistribution study was performed in normal mice after injection via tail vein. Results: The prepared kits achieved radiolabeling efficiencies in excess of 95% and showed a shelf-life of 98 days at 25 deg. C and 64.3 months at 4 deg. C. 68 Ga-BAPEN was found to be stable in human serum at 37 deg. C for at least 1 h. Furthermore, a biodistribution study revealed high heart uptake (10.8% ID/g, 1 h). Conclusions: The authors developed a BAPEN kit for convenient labeling with 68 Ga. The 68 Ga-BAPEN showed high stability and excellent biodistribution results in normal mice, which is required for myocardial PET imaging.

  7. Existence of c-Kit negative cells with ultrastructural features of interstitial cells of Cajal in the subserosal layer of the W/W(v) mutant mouse colon.

    Science.gov (United States)

    Tamada, Hiromi; Kiyama, Hiroshi

    2015-01-01

    Interstitial cells of Cajal (ICC) are mesenchymal cells that are distributed along the gastrointestinal tract and function as pacemaker cells or intermediary cells between nerves and smooth muscle cells. ICC express a receptor tyrosine kinase c-Kit, which is an established marker for ICC. The c-kit gene is allelic with the murine white-spotting locus (W), and some ICC subsets were reported to be missing in heterozygous mutant W/W(v) mice carrying W and W(v) mutated alleles. In this study, the characterization of interstitial cells in the subserosal layer of W/W(v) mice was analyzed by immunohistochemistry and electron microscopy. In the proximal and distal colon of W/W(v) mutant mice, no c-Kit-positive cells were detected in the subserosal layer by immunohistochemistry. By electron microscopy, the interstitial cells, which were characterized by the existence of caveolae, abundant mitochondria and gap junctions, were observed in the W/W(v) mutant colon. The morphological characteristics were comparable to those of the multipolar c-Kit positive ICC seen in the subserosa of proximal and distal colon of wild-type mice. Fibroblasts were also located in the same layers, but the morphology of the fibroblasts was distinguishable from that of ICC in wild type mice or of ICC-like cells in W/W(v) mutant mice. Collectively, it is concluded that c-Kit-negative interstitial cells showing a typical ICC ultrastructure exist in the proximal and distal colon of W/W(v) mutant mice.

  8. c-Kit signaling determines neointimal hyperplasia in arteriovenous fistulae

    Science.gov (United States)

    Skartsis, Nikolaos; Martinez, Laisel; Duque, Juan Camilo; Tabbara, Marwan; Velazquez, Omaida C.; Asif, Arif; Andreopoulos, Fotios; Salman, Loay H.

    2014-01-01

    Stenosis of arteriovenous (A-V) fistulae secondary to neointimal hyperplasia (NIH) compromises dialysis delivery, which worsens patients' quality of life and increases medical costs associated with the maintenance of vascular accesses. In the present study, we evaluated the role of the receptor tyrosine kinase c-Kit in A-V fistula neointima formation. Initially, c-Kit was found in the neointima and adventitia of human brachiobasilic fistulae, whereas it was barely detectable in control veins harvested at the time of access creation. Using the rat A-V fistula model to study venous vascular remodeling, we analyzed the spatial and temporal pattern of c-Kit expression in the fistula wall. Interestingly, c-Kit immunoreactivity increased with time after anastomosis, which concurred with the accumulation of cells in the venous intima. In addition, c-Kit expression in A-V fistulae was positively altered by chronic kidney failure conditions. Both blockade of c-Kit with imatinib mesylate (Gleevec) and inhibition of stem cell factor production with a specific short hairpin RNA prevented NIH in the outflow vein of experimental fistulae. In agreement with these data, impaired c-Kit activity compromised the development of NIH in A-V fistulae created in c-KitW/Wv mutant mice. These results suggest that targeting of the c-Kit signaling pathway may be an effective approach to prevent postoperative NIH in A-V fistulae. PMID:25186298

  9. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  10. Performance of the Angio Detect™ in-clinic test kit for detection of Angiostrongylus vasorum infection in dog samples from Europe

    DEFF Research Database (Denmark)

    Liu, Jiayou; Schnyder, Manuela; Willesen, Jakob L.

    2017-01-01

    of the Angio Detect test kit by comparing Angio Detect testing results using serum or plasma samples with the results of Baermann-Wetzel testing using matched fecal samples. Samples from 214 dogs [with clinically suspected (N = 195) or diagnosed angiostrongylosis (N = 19)] were used for this evaluation......; sensitivity of the Angio Detect test was 97.1% (95%CI: 85.1%–99.9%). The Angio Detect test was negative for 177 of 179 samples that were negative by the Baermann-Wetzel test; specificity was 98.9% (95%CI: 96.0%–99.9%). In cross-reactivity testing, all 89 samples from dogs confirmed to be infected with other...... common nematodes (Dirofilaria immitis, D. repens, Crenosoma vulpis, hookworms, ascarids, or whipworms) were all negative for A. vasorum by the Angio Detect antigen test. Angio Detect provides a rapid and reliable method for diagnosis of A. vasorum in clinically suspected dogs at risk for infection...

  11. Energy Management Curriculum Starter Kit

    Energy Technology Data Exchange (ETDEWEB)

    Turner, W.C.

    1987-02-01

    The Energy Management Curriculum Starter Kit was designed to help engineering educators develop and teach energy management courses. Montana State University and Oklahoma State University courses are embodied in the model curriculum given. The curricula offered at many other universities throughout the United States are also presented. The kit was designed specifically to train engineering students to be good energy managers. Courses at both the undergraduate and postgraduate level are presented.

  12. Quantitative structure–activity relationships for toxicity and genotoxicity of halogenated aliphatic compounds: Wing spot test of Drosophila melanogaster

    Czech Academy of Sciences Publication Activity Database

    Chroust, K.; Pavlová, M.; Prokop, Z.; Mendel, Jan; Božková, K.; Kubát, Z.; Zajíčková, V.; Damborský, J.

    2007-01-01

    Roč. 67, č. 1 (2007), s. 152-159 ISSN 0045-6535 Institutional research plan: CEZ:AV0Z60930519 Keywords : toxicity * wing spot test * QSAR Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.739, year: 2007

  13. CERN’s FMC Kit

    CERN Document Server

    Cattin, M; Serrano, J; van der Bij, E; Wlostowski, T

    2014-01-01

    In the context of the renovation of controls and data acquisition electronics for accelerators the BE-CO-HT section at CERN has designed a kit based on carriers and mezzanines following the VITA FPGAMezzanine Card (FMC) standard. Carriers exist in VME64x and PCIe form factors, with a PXIe carrier underway. Mezzanines include an Analog to Digital Converter, a Time to Digital Converter, a fine delay generator and a Digital Input/Output. All of the designs are licensed under the CERN Open Hardware Licence and commercialised by companies. This paper discusses the benefits of this carrier mezzanine strategy and of the Open Hardware based commercial paradigm. It also explains the design of each layer of the FMC kit, from the hardware to the gateware and the Linux device driver. In addition, several tools to help designers developing gateware for mezzanines and new concepts such as the Self-Describing Bus (SDB) and the fmcbus are presented. Lastly, some of the plans for the future of the FMC kit and Open Hardware Re...

  14. The Fluid Dynamics Demo Kit: Part I

    Science.gov (United States)

    Flack, Karen; Underhill, Patrick; Prestridge, Kathy

    2012-11-01

    The goal of this project is to develop a fluid dynamics demonstration/experiment kit that can be used by professors and graduate students at high school outreach events. The demonstrations in the kit will be easy to use and true crowd pleasers in order to inspire understanding and pique curiosity about the physics of flow. The kits will be inexpensive, containing readily available materials so that teachers can duplicate the demonstrations and experiments. The kits will be left with the teachers as a gift from the American Physics Society. The experiments and demonstrations cover the concepts of conservation of mass, momentum, and energy, Bernoulli's equation, frictional losses and the ideal gas law. For each experiment, the teachers will receive presentation material, access to instructional videos, plus a worksheet that can be used in a high school physics classroom. This kit has been developed through the efforts of the APS-DFD Mentoring and Outreach Committee and has received funding from the APS-DFD. Work funded by the APS-DFD.

  15. A fiber-optic polarimetric demonstration kit

    International Nuclear Information System (INIS)

    Eftimov, T; Dimitrova, T L; Ivanov, G

    2012-01-01

    A simple and multifunctional fiber-optic polarimetric kit on the basis of highly birefringent single-mode fibers is presented. The fiber-optic polarimetric kit allows us to perform the following laboratory exercises: (i) fiber excitation and the measurement of numerical aperture, (ii) polarization preservation and (iii) obtain polarization-sensitive fiberized interferometers.

  16. 33 CFR 144.01-30 - First-aid kit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  17. Information contained within the large scale gas injection test (Lasgit) dataset exposed using a bespoke data analysis tool-kit

    International Nuclear Information System (INIS)

    Bennett, D.P.; Thomas, H.R.; Cuss, R.J.; Harrington, J.F.; Vardon, P.J.

    2012-01-01

    Document available in extended abstract form only. The Large Scale Gas Injection Test (Lasgit) is a field scale experiment run by the British Geological Survey (BGS) and is located approximately 420 m underground at SKB's Aespoe Hard Rock Laboratory (HRL) in Sweden. It has been designed to study the impact on safety of gas build up within a KBS-3V concept high level radioactive waste repository. Lasgit has been in almost continuous operation for approximately seven years and is still underway. An analysis of the dataset arising from the Lasgit experiment with particular attention to the smaller scale features and phenomenon recorded has been undertaken in parallel to the macro scale analysis performed by the BGS. Lasgit is a highly instrumented, frequently sampled and long-lived experiment leading to a substantial dataset containing in excess of 14.7 million datum points. The data is anticipated to include a wealth of information, including information regarding overall processes as well as smaller scale or 'second order' features. Due to the size of the dataset coupled with the detailed analysis of the dataset required and the reduction in subjectivity associated with measurement compared to observation, computational analysis is essential. Moreover, due to the length of operation and complexity of experimental activity, the Lasgit dataset is not typically suited to 'out of the box' time series analysis algorithms. In particular, the features that are not suited to standard algorithms include non-uniformities due to (deliberate) changes in sample rate at various points in the experimental history and missing data due to hardware malfunction/failure causing interruption of logging cycles. To address these features a computational tool-kit capable of performing an Exploratory Data Analysis (EDA) on long-term, large-scale datasets with non-uniformities has been developed. Particular tool-kit abilities include: the parameterization of signal variation in the dataset

  18. Distribution and ultrastructure of interstitial cells of Cajal in the mouse colon, using antibodies to Kit and Kit(W-lacZ) mice

    DEFF Research Database (Denmark)

    Vanderwinden, J M; Rumessen, J J; Bernex, F

    2000-01-01

    kinase receptor Kit as a marker. Sections and whole mounts were studied by confocal microscopy after double immunofluorescence with specific antibodies. The ultrastructure of Kit-expressing cells was examined by electron microcopy in KitW-lacz/+ transgenic mice, which carry the lacz gene inserted...

  19. c-Kit expression in somatosensory nuclei of lower medulla oblongata.

    Science.gov (United States)

    Pop, Elena; Mărdărescu, Mariana; Lazăr, M; Rusu, M C; Ion, Daniela Adriana

    2013-01-01

    Protein kinase signal-transduction pathways play critical roles in regulating nociception. The c-kit receptor contributes to pain regulation in the spinal cord and is present on both peripheral and central terminals. Expression of c-kit was demonstrated in human trigeminal and spinal ganglia. However, the brainstem expression of c-kit was overlooked. We aimed to evaluate it by immunohistochemistry, on eight samples of human lower medulla oblongata. We used two clones of CD117/c-kit antibodies, from different manufacturers, and neurofilament antibodies. Positive expression of CD117/c-kit was found within the spinal trigeminal nucleus, the gracilis, cuneate, and lateral cuneate nuclei, and within the olivary complex. CD117/c-kit positive interstitial networks of these nuclei were positively labeled with neurofilaments. CD117/c-kit labeled the olivary neurons, but not the magnocellular neurons of the trigeminal, gracilis and cuneate nuclei. c-kit interstitial systems of brainstem could play so an important role for the functional status along the somatosensory neural circuits.

  20. An Investigation of the Measurement Properties of the Spot-the-Word Test In a Community Sample

    Science.gov (United States)

    Mackinnon, Andrew; Christensen, Helen

    2007-01-01

    Intellectual ability is assessed with the Spot-the-Word (STW) test (A. Baddeley, H. Emslie, & I. Nimmo Smith, 1993) by asking respondents to identify a word in a word-nonword item pair. Results in moderate-sized samples suggest this ability is resistant to decline due to dementia. The authors used a 3-parameter item response theory model to…

  1. Validation of Geno-Sen's scrub typhus real time polymerase chain reaction kit by its comparison with a serological ELISA Test

    Directory of Open Access Journals (Sweden)

    Velmurugan Anitharaj

    2017-01-01

    Full Text Available Background: In the recent past, scrub typhus (ST has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA/indirect immunofluorescence assay (IFA. Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016. All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India. Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA. Chi-square test with Yates correction (Fisher's test was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.

  2. Basic and clinical evaluation of CA 130 RIA kit (D-7111) using two newly developed monoclonal antibodies. Comparison with CA 125 kit

    Energy Technology Data Exchange (ETDEWEB)

    Saga, Tsuneo; Endo, Keigo; Nakajima, Tetsuo and others

    1988-10-01

    The CA 130 RIA kit was developed with the use of two monoclonal antibodies, 130 - 22 and 145 - 9. Laboratory performance was satisfactory for precision, reproducibility, recovery, and dilution. Measurement values with CA 130 kit were almost consistent with those with CA 125 kit. Favorable standard curves were attained with smaller concentrations and shorter incubation time of CA 130 kit than those with CA 125 kit. There was less prozone phenomenon. When defining a cut-off serum level of CA 130 as 35 U/ml, false-positive rate was 0 % for healthy men and 4 % for healthy women, suggesting the involvement of menstrual cycle. Positive rate for CA 130 was 65 % for malignant ovarian tumor, 48 % for lung cancer, and 47 % for endometriosis. (Namekawa, K.).

  3. Comparison of two commercial DNA extraction kits for the analysis of nasopharyngeal bacterial communities

    Directory of Open Access Journals (Sweden)

    Keith A. Crandall

    2016-04-01

    Full Text Available Characterization of microbial communities via next-generation sequencing (NGS requires an extraction ofmicrobial DNA. Methodological differences in DNA extraction protocols may bias results and complicate inter-study comparisons. Here we compare the effect of two commonly used commercial kits (Norgen and Qiagenfor the extraction of total DNA on estimatingnasopharyngeal microbiome diversity. The nasopharynxis a reservoir for pathogens associated with respiratory illnesses and a key player in understandingairway microbial dynamics. Total DNA from nasal washes corresponding to 30 asthmatic children was extracted using theQiagenQIAamp DNA and NorgenRNA/DNA Purification kits and analyzed via IlluminaMiSeq16S rRNA V4 ampliconsequencing. The Norgen samples included more sequence reads and OTUs per sample than the Qiagen samples, but OTU counts per sample varied proportionallybetween groups (r = 0.732.Microbial profiles varied slightly between sample pairs, but alpha- and beta-diversity indices (PCoAand clustering showed highsimilarity between Norgen and Qiagenmicrobiomes. Moreover, no significant differences in community structure (PERMANOVA and adonis tests and taxa proportions (Kruskal-Wallis test were observed betweenkits. Finally, aProcrustes analysis also showed low dissimilarity (M2 = 0.173; P< 0.001 between the PCoAs of the two DNA extraction kits. Contrary to what has been observed in previous studies comparing DNA extraction methods, our 16S NGS analysis of nasopharyngeal washes did not reveal significant differences in community composition or structure between kits. Our findingssuggest congruence between column-based chromatography kits and supportthe comparison of microbiomeprofilesacross nasopharyngeal metataxonomic studies.

  4. A comparative study of faecal occult blood kits in a colorectal cancer screening program in a cohort of healthy construction workers.

    LENUS (Irish Health Repository)

    Shuhaibar, M

    2012-02-01

    BACKGROUND: The incidence of colorectal cancer (CRC) has been increasing. We evaluated uptake rates and outcomes of faecal immunochemical test (FIT) and Guaiac test (gFOBT) kits as part of a two-step CRC screening. METHODS: A 3-year CRC screening program for a defined population of construction workers was conducted. Those satisfying the inclusion criteria were provided with gFOBT or FIT kits. Individuals testing positive were invited for a colonoscopy. RESULTS: A total of 909 faecal testing kits were distributed. Age range was 53-60 years. Compliance rate was higher for FIT (58.3%) as compared to gFOBT (46.7%) (p = 0.0006). FIT detected adenomatous polyps and CRC in 37.5 and 25%, respectively, whereas; gFOBT detected 23.5 and 18%. Colonoscopies were normal in 53 and 25% tested positive by gFOBT and FIT, respectively (p = 0.016). CONCLUSION: The FIT was more cost-effective when compared with gFOBT with higher return rate, sensitivity and specificity. A comparative study of faecal occult blood kits in a CRC screening program in a healthy cohort of construction workers.

  5. A new field test kit for the rapid determination of diesel fuel in soil

    International Nuclear Information System (INIS)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.; Hart, J.K.

    1995-01-01

    A new test kit is available for evaluating diesel and other fuel contamination in soils. While the Freon extraction/infrared method estimates fuel concentration by measuring aliphatic C-H stretch, approaches designed to replace this such as the immunoassay method and the method involving a Fridel-Crafts alkylation reaction measure the aromatic component of fuel mixtures. Both of these methods measure aromatic content indirectly with visible color development. The new method measures the aromatic components directly with a 254 nm portable field photometer. The method is very simple since it does not involve complicated color development steps, and does not require the use of highly toxic reagents. It involves a 3-minute extraction of soil with a 10:1 ratio of isopropyl alcohol. Prior to extraction, the soil is treated with an agent to minimize the extraction of humic materials which can interfere. The extract solution is passed through a syringe filter and the absorbance is read at 254 nm. The fuel concentration is calculated based on average relative response factors. Alternatively, the actual contaminant fuel can be used as a standard if it is known. The quantitation limit is about 75 mg/kg diesel in soil. The method has been tested with a variety of soils and fuel types

  6. Testing Co-Volatility Spillovers for Natural Gas Spot, Futures and ETF Spot using Dynamic Conditional Covariances

    NARCIS (Netherlands)

    C-L. Chang (Chia-Lin); M.J. McAleer (Michael); Y. Wang (Yanghuiting)

    2016-01-01

    textabstractThere is substantial empirical evidence that energy and financial markets are closely connected. As one of the most widely-used energy resources worldwide, natural gas has a large daily trading volume. In order to hedge the risk of natural gas spot markets, a large number of hedging

  7. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries.

    Science.gov (United States)

    Frati, Elena Rosanna; Martinelli, Marianna; Fasoli, Ester; Colzani, Daniela; Bianchi, Silvia; Binda, Sandro; Olivani, Pierfranco; Tanzi, Elisabetta

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56-99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88-99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28-100) at both time points. The concordance between DUS and fresh urine HPV testing was "almost perfect" using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  8. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    Directory of Open Access Journals (Sweden)

    Elena Rosanna Frati

    2015-01-01

    Full Text Available Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV testing from dried urine spots (DUS. Eighty-eight urine samples (including 56 HPV DNA positive specimens were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68 for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01 for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100 at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  9. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    Science.gov (United States)

    Olivani, Pierfranco

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100) at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries. PMID:26180790

  10. Chemistry of /sup 99m/Tc labeling kits

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.; Richards, P.

    1976-01-01

    Problems have been reported with the use of kit-produced /sup 99m/Tc radiopharmaceuticals. This study was undertaken to understand the chemistry involved in various stannous kit systems. The relation between Tc, tin, and the ligands used to complex the reduced Tc was investigated. It is concluded that for reliable performance, stannous kits should be prepared so that most of the tin is kept in the usable (reducing) form; a solution would be to use minimum tin and a large excess of complexing agent. Oxidation of the Tc complex to free pertechnetate is not a major problem in most kit systems. 5 figures

  11. Building Use Policies. SPEC Kit 144.

    Science.gov (United States)

    Coyle, Patrick

    This Systems and Procedures Exchange Center (SPEC) flyer/kit addresses some of the needs of Association of Research Libraries (ARL) members regarding library building use and the aesthetics and well-being of the materials and people in the building. The kit draws upon documents gathered as part of a 1986 Quick-SPEC survey that dealt with food and…

  12. Spot: A Programming Language for Verified Flight Software

    Science.gov (United States)

    Bocchino, Robert L., Jr.; Gamble, Edward; Gostelow, Kim P.; Some, Raphael R.

    2014-01-01

    The C programming language is widely used for programming space flight software and other safety-critical real time systems. C, however, is far from ideal for this purpose: as is well known, it is both low-level and unsafe. This paper describes Spot, a language derived from C for programming space flight systems. Spot aims to maintain compatibility with existing C code while improving the language and supporting verification with the SPIN model checker. The major features of Spot include actor-based concurrency, distributed state with message passing and transactional updates, and annotations for testing and verification. Spot also supports domain-specific annotations for managing spacecraft state, e.g., communicating telemetry information to the ground. We describe the motivation and design rationale for Spot, give an overview of the design, provide examples of Spot's capabilities, and discuss the current status of the implementation.

  13. Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.

    Science.gov (United States)

    Schou, T M; Malmkvist, J

    2017-09-01

    We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we

  14. Utilization of milk energy by suckling mink kits

    DEFF Research Database (Denmark)

    Tauson, Anne-Helene; Fink, Rikke; Hansen, Kirsten Bislev

    2004-01-01

    A total of 36 mink dams and their litters of 3, 6 or 9 kits were used for determination of milk intake of the suckling young by means of deuterium dilution technique, and chemical composition of milk and of kit bodies. Measurements were performed during lactation weeks 1-4, each week with 3 dams...... with each litter size. Milk intake was determined over a 48 h measurement period, and by the end of this milk samples were collected and 2 kits (litters of 6 and 9) or 1 kit per litter (litters of 3) were killed for body chemical composition. Based on the results, different models were applied...... for calculation of the energetic efficiency of milk. Dam milk yield increased steadily from week 1 until week 3 but only slightly from week 3 to 4. The increase declined with increasing litter size, and for dams suckling 9 kits the increment from week 3 to week 4 was only 2 g. The dry matter content of milk...

  15. KiT: a MATLAB package for kinetochore tracking.

    Science.gov (United States)

    Armond, Jonathan W; Vladimirou, Elina; McAinsh, Andrew D; Burroughs, Nigel J

    2016-06-15

    During mitosis, chromosomes are attached to the mitotic spindle via large protein complexes called kinetochores. The motion of kinetochores throughout mitosis is intricate and automated quantitative tracking of their motion has already revealed many surprising facets of their behaviour. Here, we present 'KiT' (Kinetochore Tracking)-an easy-to-use, open-source software package for tracking kinetochores from live-cell fluorescent movies. KiT supports 2D, 3D and multi-colour movies, quantification of fluorescence, integrated deconvolution, parallel execution and multiple algorithms for particle localization. KiT is free, open-source software implemented in MATLAB and runs on all MATLAB supported platforms. KiT can be downloaded as a package from http://www.mechanochemistry.org/mcainsh/software.php The source repository is available at https://bitbucket.org/jarmond/kit and under continuing development. Supplementary data are available at Bioinformatics online. jonathan.armond@warwick.ac.uk. © The Author 2016. Published by Oxford University Press.

  16. Self-sampling kits to increase HIV testing among black Africans in the UK: the HAUS mixed-methods study.

    Science.gov (United States)

    Seguin, Maureen; Dodds, Catherine; Mugweni, Esther; McDaid, Lisa; Flowers, Paul; Wayal, Sonali; Zomer, Ella; Weatherburn, Peter; Fakoya, Ibidun; Hartney, Thomas; McDonagh, Lorraine; Hunter, Rachael; Young, Ingrid; Khan, Shabana; Freemantle, Nick; Chwaula, Jabulani; Sachikonye, Memory; Anderson, Jane; Singh, Surinder; Nastouli, Eleni; Rait, Greta; Burns, Fiona

    2018-04-01

    Timely diagnosis of human immunodeficiency virus (HIV) enables access to antiretroviral treatment, which reduces mortality, morbidity and further transmission in people living with HIV. In the UK, late diagnosis among black African people persists. Novel methods to enhance HIV testing in this population are needed. To develop a self-sampling kit (SSK) intervention to increase HIV testing among black Africans, using existing community and health-care settings (stage 1) and to assess the feasibility for a Phase III evaluation (stage 2). A two-stage, mixed-methods design. Stage 1 involved a systematic literature review, focus groups and interviews with key stakeholders and black Africans. Data obtained provided the theoretical base for intervention development and operationalisation. Stage 2 was a prospective, non-randomised study of a provider-initiated, HIV SSK distribution intervention targeted at black Africans. The intervention was assessed for cost-effectiveness. A process evaluation explored feasibility, acceptability and fidelity. Twelve general practices and three community settings in London. HIV SSK return rate. Stage 1 - the systematic review revealed support for HIV SSKs, but with scant evidence on their use and clinical effectiveness among black Africans. Although the qualitative findings supported SSK distribution in settings already used by black Africans, concerns were raised about the complexity of the SSK and the acceptability of targeting. These findings were used to develop a theoretically informed intervention. Stage 2 - of the 349 eligible people approached, 125 (35.8%) agreed to participate. Data from 119 were included in the analysis; 54.5% (65/119) of those who took a kit returned a sample; 83.1% of tests returned were HIV negative; and 16.9% were not processed, because of insufficient samples. Process evaluation showed the time pressures of the research process to be a significant barrier to feasibility. Other major barriers were

  17. The cobalt spot test - further insights into its performance and use

    DEFF Research Database (Denmark)

    Midander, Klara; Julander, Anneli; Skare, Lizbet

    2013-01-01

    A spot test was recently developed for easy and rapid testing to detect whether cobalt is available on surfaces in contact with skin.......A spot test was recently developed for easy and rapid testing to detect whether cobalt is available on surfaces in contact with skin....

  18. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  19. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...... and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly...

  20. Antigenotoxic effects of Citrus aurentium L. fruit peel oil on mutagenicity of two alkylating agents and two metals in the Drosophila wing spot test.

    Science.gov (United States)

    Demir, Eşref; Kocaoğlu, Serap; Cetin, Huseyin; Kaya, Bülent

    2009-07-01

    Antigenotoxic effects of Citrus aurentium L. (Rutaceae) fruit peel oil (CPO) in combination with mutagenic metals and alkylating agents were studied using the wing spot test of D. melanogaster. The four reference mutagens, potassium dichromate (K2Cr2O7), cobalt chloride (CoCl2), ethylmethanesulfonate (EMS), and N-ethyl-N-nitrosourea (ENU) were clearly genotoxic. CPO alone at doses from 0.1 to 0.5% in Tween 80 was not mutagenic and did not enhance the mutagenic effect of the reference mutagens. However, antigenotoxic effects of CPO were clearly demonstrated in chronic cotreatments with mutagens and oil, by a significant decrease in wing spots induced by all four mutagens. The D. melanogaster wing spot test was found to be a suitable assay for detecting antigenotoxic effects in vivo. Copyright 2009 Wiley-Liss, Inc.

  1. Evaluating the Medical Kit System for the International Space Station(ISS) - A Paradigm Revisited

    Science.gov (United States)

    Hailey, Melinda J.; Urbina, Michelle C.; Hughlett, Jessica L.; Gilmore, Stevan; Locke, James; Reyna, Baraquiel; Smith, Gwyn E.

    2010-01-01

    Medical capabilities aboard the International Space Station (ISS) have been packaged to help astronaut crew medical officers (CMO) mitigate both urgent and non-urgent medical issues during their 6-month expeditions. Two ISS crewmembers are designated as CMOs for each 3-crewmember mission and are typically not physicians. In addition, the ISS may have communication gaps of up to 45 minutes during each orbit, necessitating medical equipment that can be reliably operated autonomously during flight. The retirement of the space shuttle combined with ten years of manned ISS expeditions led the Space Medicine Division at the NASA Johnson Space Center to reassess the current ISS Medical Kit System. This reassessment led to the system being streamlined to meet future logistical considerations with current Russian space vehicles and future NASA/commercial space vehicle systems. Methods The JSC Space Medicine Division coordinated the development of requirements, fabrication of prototypes, and conducted usability testing for the new ISS Medical Kit System in concert with implementing updated versions of the ISS Medical Check List and associated in-flight software applications. The teams constructed a medical kit system with the flexibility for use on the ISS, and resupply on the Russian Progress space vehicle and future NASA/commercial space vehicles. Results Prototype systems were developed, reviewed, and tested for implementation. Completion of Preliminary and Critical Design Reviews resulted in a streamlined ISS Medical Kit System that is being used for training by ISS crews starting with Expedition 27 (June 2011). Conclusions The team will present the process for designing, developing, , implementing, and training with this new ISS Medical Kit System.

  2. Bier spots

    Directory of Open Access Journals (Sweden)

    Ahu Yorulmaz,

    2015-10-01

    Full Text Available Also called as physiologic anemic macules, Bier spots are small, hypopigmented irregularly shaped macules against a background of diffuse erythema, which creates an appearance of speckled vascular mottling of the skin. Bier spots most commonly appear on distal portions of the limbs though there are case reports describing diffuse involvement, which also affect trunk and mucous membranes of the patient. Although the exact pathophysiological mechanisms underlying Bier spots still need to be elucidated, Bier spots have been suggested to be a vascular anomaly caused by vasoconstriction of small vessels. In addition, several diseases have been proposed to be associated with Bier spots, including scleroderma renal crisis, cryoglobulinemia, Peutz-Jeghers syndrome, alopecia areata and hypoplasia of the aorta, although it has not been shown whether these associations are casual or coincidental. The clinical presentation of Bier spots is quite typical. These tiny whitish macules easily become prominent when the affected limb is placed in a dependent position and fade away when the limb is raised. Here we report a case of Bier spots in a 32-year-old male patient with characteristical clinical manifestations.

  3. Evaluation of Two Commercial Enzyme-Linked Immunosorbent Assay Kits for the Detection of Human Circulating Metrnl.

    Science.gov (United States)

    Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu

    2018-04-01

    Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.

  4. Effect of Radioactivity of Technetium-99m on the Autosterilization Process of non-sterile Tetrofosmin Kits

    Directory of Open Access Journals (Sweden)

    Widyastuti Widyastuti

    2017-03-01

    Full Text Available Technetium-99m labeled radiopharmaceutical is commonly used in nuclear medicines as a diagnostic agent, by mixing the sterile kit with Tc-99m. Manufacturing of kits requires an aseptic facility which need to be well designed and maintained according to cGMP, since mostly kits can not be terminally sterilized. Radiopharmaceuticals as pharmaceuticals containing radionuclide is assumed to have an autosterilization property, but correlation between radioactivity and capability of killing microorganisms has to be studied so far. The aim of this study is to investigate the effect of radioactivity on the autosterilization process of radiopharmaceuticals. The study was carried out by adding Tc-99m of various radioactivity into non-sterile tetrofosmin kits, then the samples were tested for sterility. Sterile tetrofosmin kit and non-sterile kit with no Tc-99m added will be used as a negative control and positive control respectively. The sterility was tested using standard direct inoculation method, by inoculating samples in culture media for both bacteria and fungi and observing qualitatively within 14 days. The results showed that the samples with radioactivity of 1, 3 and 5 mCi changed the clarity of the media to turbid, conformed with the performance of positive controls but samples with radioactivity of 10 mCi and 20 mCi did not change the clarity of the media, conformed with the performance of negative control, indicating neither growth of bacteria nor fungi. It is concluded that Tc-99m behaves as an autosterilizing agent at certain radioactivity. Therefore the preparation of Tc-99m radiopharmaceutical can be considered as terminal sterilization rather than aseptic preparation.

  5. The Winfrith lecturers' demonstration kits for radiation and radioactivity

    International Nuclear Information System (INIS)

    Woffinden, G.B.

    1981-01-01

    During the early part of the 1970s a need arose for suitable aids to assist lecturers in giving talks on radioactivity and radiation to employees and occasionally to science students in local schools and colleges. A kit capable of demonstrating the basic properties of alpha, beta and gamma radiation was assembled for these purposes. During the latter half of the decade a demand arose for talks to non-scientific groups of the general public on nuclear power and radiation and some of the items in the original demonstration kit were found to be appropriate for these talks. The items used, now constitute the Basic Demonstration Kit. Meanwhile, a few changes or additions were made to the original kit which is now known as the Comprehensive Demonstration Kit. (author)

  6. Identification of the Quality Spot Welding used Non Destructive Test-Ultrasonic Testing: (Effect of Welding Time)

    Science.gov (United States)

    Sifa, A.; Endramawan, T.; Badruzzaman

    2017-03-01

    Resistance Spot Welding (RSW) is frequently used as one way of welding is used in the manufacturing process, especially in the automotive industry [4][5][6][7]. Several parameters influence the process of welding points. To determine the quality of a welding job needs to be tested, either by damaging or testing without damage, in this study conducted experimental testing the quality of welding or identify quality of the nugget by using Non-Destructive Test (NDT) -Ultrasonic Testing (UT), in which the identification of the quality of the welding is done with parameter thickness of worksheet after welding using NDT-UT with use same material worksheet and have more thickness of worksheet, the thickness of the worksheet single plate 1mm, with the capability of propagation Ultrasonic Testing (UT) standard limited> 3 mm [1], welding process parameters such as the time difference between 1-10s and the welding current of 8 KV, visually Heat Affected Zone ( HAZ ) have different results due to the length of time of welding. UT uses a probe that is used with a frequency of 4 MHz, diameter 10 mm, range 100 and the couplant used is oil. Identification techniques using drop 6dB, with sound velocity 2267 m / s of Fe, with the result that the effect of the Welding time affect the size of the HAZ, identification with the lowest time 1s show results capable identified joined through NDT - UT.

  7. Training Educators to Teach the Sun and Space Weather Using a Kit of Tools

    Science.gov (United States)

    Keesee, A. M.; Ensign, T.

    2014-12-01

    NASA provides a wealth of data from Heliospheric missions to the public, but educators face several challenges to using such data in the classroom. These include the knowledge of what is available and how to use it, a full understanding of the science concepts the data demonstrate, ability to obtain and maintain products to access data, and access to technology (such as computer labs) for anything other than testing. To surmount these challenges, the Educator Resource Center at the NASA Independent Validation and Verification (IV&V) Center in Fairmont, WV has developed an operational model that focuses on housing, maintaining, and lending out kits of necessary equipment along with training educators in the science concepts and use of kit materials. Following this model, we have developed a Sun and Space Weather kit and an educator professional development course that we have presented several times. The kit includes a classroom set of iPads utilized to access data from NASA missions and other sources as well as create video reports for project based outcomes, a set of telescopes for safe solar viewing, and materials to explore magnetic fields and the electromagnetic spectrum. We will present an overview of the training course, the kit materials, and lessons learned.

  8. Experimental and simulated strength of spot welds

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Bennedbæk, Rune A.K.; Larsen, Morten B.

    2014-01-01

    Weld strength testing of single spots in DP600 steel is presented for the three typical testing procedures, i.e. tensile-shear, cross-tension and peel testing. Spot welds are performed at two sets of welding parameters and strength testing under these conditions is presented by load......-elongation curves revealing the maximum load and the elongation at break. Welding and strength testing is simulated by SORPAS® 3D, which allows the two processes to be prepared in a combined simulation, such that the simulated welding properties are naturally applied to the simulation of strength testing. Besides...... the size and shape of the weld nugget, these properties include the new strength of the material in the weld and the heat affected zone based on the predicted hardness resulting from microstructural phase changes simulated during cooling of the weld before strength testing. Comparisons between overall...

  9. SPOT: How good for geology? A comparison with LANDSAT MSS

    Science.gov (United States)

    Sesoeren, A.

    1986-12-01

    Geological interpretation possibilities of SPOT MSS and LANDSAT MSS positive prints enlarged to the same scale were compared, using as a test area part of the Jebel Amour (Algeria). The SPOT imagery offers many advantages, filling the gap between remote sensing from space and aerial photography. The best results by visual interpretation are obtained in combining SPOT for the required details with LANDSAT for the synoptic veiw. Further improvements are expected from the use of SPOT stereo-pairs.

  10. Synthetic positive controls for ELISA test kits for detection of IgA and IgM antibodies to Chlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    O. Y. Galkin

    2015-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA is the most informative and versatile method of serological diagnostics. The possibility of detecting by ELISA specific antibodies of different classes allow to differentiate primary infectious process and its remission, exacerbation and chronic disease (holding of differential diagnosis. This approach is implemented in the methodology for evaluation of patients for presence of humoral immune response against the causative agent of urogenital chlamydiosis. As with other infections immediately after Chlamydia trachomatis infection the specific IgM antibodies are formed, and subsequently basic projective antibodies of IgG class are synthesized. However, at exacerbation of chronic urogenital chlamydiosis specific IgA antibodies can be synthesized. That is why comprehensive evaluation of patients for presence of humoral immune response to Ch. trachomatis involves plasma testing of specific antibodies of all three classes. The essential problem in the production of ELISA diagnostic kits is obtaining of positive control. The classic version of positive control is human blood plasma containing specific antibodies. But specific IgM- and IgA-positive sera are deficit raw materials. This fact can significantly limit the production of diagnostic kits, especially in case of large-scale manufacture. We have suggested methodological approach to use of synthetic positive controls in indirect ELISA kits based on conjugate of normal human IgM (IgA and monoclonal antibodies against major outer membrane protein of Ch. trachomatis. It was found that it’s possible to realize such task by means of NHS ester-maleimide-mediated conjugation (by sulfosuccinimidyl-4-(N-maleimidomethylcyclohexane-1-carboxylate and reductive amination-mediated conjugation (by sodium periodate. It was found that synthetic positive controls obtained by different methods are characterized by higher titer compared to IgM- and IgA-positive high

  11. SU-E-T-510: Interplay Between Spots Sizes, Spot / Line Spacing and Motion in Spot Scanning Proton Therapy

    International Nuclear Information System (INIS)

    Lee, TK

    2015-01-01

    Purpose In proton beam configuration for spot scanning proton therapy (SSPT), one can define the spacing between spots and lines of scanning as a ratio of given spot size. If the spacing increases, the number of spots decreases which can potentially decrease scan time, and so can whole treatment time, and vice versa. However, if the spacing is too large, the uniformity of scanned field decreases. Also, the field uniformity can be affected by motion during SSPT beam delivery. In the present study, the interplay between spot/ line spacing and motion is investigated. Methods We used four Gaussian-shape spot sizes with 0.5cm, 1.0cm, 1.5cm, and 2.0cm FWHM, three spot/line spacing that creates uniform field profile which are 1/3*FWHM, σ/3*FWHM and 2/3*FWHM, and three random motion amplitudes within, +/−0.3mm, +/−0.5mm, and +/−1.0mm. We planned with 2Gy uniform single layer of 10×10cm2 and 20×20cm2 fields. Then, mean dose within 80% area of given field size, contrubuting MU per each spot assuming 1cGy/MU calibration for all spot sizes, number of spots and uniformity were calculated. Results The plans with spot/line spacing equal to or smaller than 2/3*FWHM without motion create ∼100% uniformity. However, it was found that the uniformity decreases with increased spacing, and it is more pronounced with smaller spot sizes, but is not affected by scanned field sizes. Conclusion It was found that the motion during proton beam delivery can alter the dose uniformity and the amount of alteration changes with spot size which changes with energy and spot/line spacing. Currently, robust evaluation in TPS (e.g. Eclipse system) performs range uncertainty evaluation using isocenter shift and CT calibration error. Based on presented study, it is recommended to add interplay effect evaluation to robust evaluation process. For future study, the additional interplay between the energy layers and motion is expected to present volumetric effect

  12. Resistance spot weldability of 11Cr–ferritic/martensitic steel sheets

    International Nuclear Information System (INIS)

    Uwaba, Tomoyuki; Yano, Yasuhide; Ito, Masahiro

    2012-01-01

    Resistance spot welding of 11Cr–0.4Mo–2W, V, Nb ferritic/martensitic steel sheets with different thicknesses was examined to develop a manufacturing technology for a fast reactor fuel subassembly with an inner duct structure. In the spot welding, welding current, electrode force, welding time and holding time were varied as welding parameters to investigate the appropriate welding conditions. Welding conditions under which spot weld joints did not have either crack or void defects in the nugget could be found when the electrode force was increased to 9.8 kN. It was also found that the electrode cap with a longer tip end length was effective for preventing weld defect formations. Strength of the spot welded joint was characterized from micro hardness and shear tension tests. In addition, the ductile-to-brittle transition temperature of the spot welded joint was measured by Charpy impact tests with specimens that had notches in the welded zone.

  13. A case of psychosis after use of a detoxification kit and a review of techniques, risks, and regulations associated with the subversion of urine drug tests.

    Science.gov (United States)

    Mittal, Moneeshindra Singh; Kalia, Rachna; Khan, Ahsan Y

    2011-01-01

    The practice of drug testing in the workplace has been adopted for US federal government employees, and many state and local governments as well as private businesses have followed suit. However, a parallel industry dedicated to subverting the results of urine drug testing has emerged with little or no regulation. First, the case of a 19-year-old man who developed psychosis after the use of a detoxification kit is presented. Second, a review of the existing literature on the techniques, risks, and regulations associated with the use of drug tampering kits is provided. PubMed, Cochrane Database, and Google Scholar were searched using the keywords UDS, urine toxicology, pass the drug test, and clean UA, with no restrictions on publication date. Case reports, letters to the editor, and original research and review articles in multiple languages were reviewed, as were federal regulations and acts on the topic. The search yielded 4,082 results, of which 49 articles were selected for relevance. Some articles were later omitted as they had cited the original article and had nothing new to offer. Three commonly used tampering techniques are in vivo adulteration, urine substitution, and in vitro adulteration. Review of the literature regarding the risks involved with use of tampering kits yielded no results. In 1986, an executive order was issued requiring all federal employees to refrain from illicit drug use, and the 1988 Drug-Free Workplace Act precipitated the Substance Abuse and Mental Health Services Administration guidelines and their subsequent revisions. Recently, many states have made regulatory efforts to bring drug test defrauding under the ambit of law. Clinicians need to be aware of the tampering techniques and the possibility of false-negative urine drug tests. Cognizance of inherent risks involved with using these techniques including psychiatric and/or medical complications is also warranted. The manufacture, sale, and use of these products have little or

  14. Informational Efficiency in the USD/KRW Spot Market: Some Evidence from a Joint Runs Test and Foreigners’ Trading Rule Profits

    Directory of Open Access Journals (Sweden)

    Changmo Ahn

    2010-12-01

    Full Text Available This paper examines whether the USD/KRW spot market is efficient in processing new information by employing both the Runs Test and the foreigners' securities trading rule profitability approach. Excluding the period of 2008 financial crisis, the USD/KRW spot market is efficient in terms of close rates, but not efficient in terms of open rates. The foreigners' securities trading rule can also produce statistically significant profits if the trades are based on open prices, though not high. This implies that traders can predict future exchange rates, to some degree, with the information on foreign net purchases of securities in the Korean stock/ bond markets. If we consider the related interest differentials and transaction costs, however, the profits fade out to marginal level or below. This result implies that traders can expect the existence of predictability in the USD/KRW spot market, but not profitability.

  15. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  16. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  17. C-peptide comparative radioimmunoassays: a study of three commercial kits

    International Nuclear Information System (INIS)

    Villaume, C.; Beck, B.

    1983-01-01

    Plasma C-peptide immunoreactivity (CPR) was measured in 18 fasting subjects with three different commercial kits (RIA-mat C-peptide-, Byk-Mallinckrodt; RIA-gnost-hC-peptide, Hoechst-Behring; human C-peptide radioimmunoassay kit, Novo) The subjects were chosen as to cover a wide range of CPR concentrations (five healthy subjects, six obese subjects, three insulin-dependent diabetics, four normal subjects whose plasmas had been kept at - 20 0 C for periods of 16 or 36 months). CPR was measured with the Novo kit in eight other plasmas which were kept over a period of 36 months, with or without aprotinin. Good correlations have been established among the values found with the three kits. However, absolute concentration values for each subject as well as the dispersion of all plasma C-peptide values varied as a function of the kit used because of antibody specificity differences and because of the various separation methods. The normal range proposed changes with each kit and the blood CPR of a subject can be a normal, reduced or increased one, depending on the kit used. After several months of storage, plasma CPR degradation is observed with the three kits. A protease-inhibitor is necessary in order to avoid this C-peptide degradation due to the apparent existence of a plasma proteolytic enzyme

  18. Demography of Northern Spotted Owls in southwestern Oregon

    Science.gov (United States)

    Zabel, Cynthia J.; Salmons, Susan E.; Forsman, Eric D.; DeStefano, Stephen; Raphael, Martin G.; Gutierrez, R.J.

    1996-01-01

    Northern Spotted Owls (Strix occidentalis caurina) are associated with lower elevation, commercially valuable, late-successional coniferous forests in the Pacific Northwest. Meta-analyses of demographic parameters indicate that Northern Spotted Owl populations are declining throughout their range (Anderson and Burnham 1992, Burnham et al. this volume). Recent research has attempted to determine whether management activities have affected the viability of Spotted Owl populations, and results have led to development of conservation plans for the species (Dawson et al. 1987, Thomas et al. 1990, Murphy and Noon 1992, USDI 1992, Thomas et al. 1993b).In the Recovery Plan for the Northern Spotted Owl (USDI 1992b) threats to the species were identified as small population sizes, declining populations, limited amounts of habitat, continued loss and fragmentation of habitat, geographically isolated populations, and predation and competition from other avian species. Weather and fire are natural processes that also may affect reproductive success of Spotted Owls. Weather may be a factor in the high annual variability in fecundity of Spotted Owls, as has been suggested for other predatory bird species (Newton, 1979, 1986). However, these factors have not been addressed in previous studies of Spotted Owls.Our objectives were to estimate survival, fecundity, and annual rates of population change (l) for resident, territorial female Spotted Owls at two study areas in the coastal mountains of southwestern Oregon. We tested if the amount of rainfall was correlated with reproduction of Spotted Owls. While surveying for Spotted Owls, we documented the increased presence of Barred Owls (Strix varia), a potential competitor of Spotted Owls.

  19. Knowledge and use of unauthorized HIV self-test kits among men who have sex with men in Spain, following approval of an over-the-counter self-test in the U.S: a cross-sectional study.

    Science.gov (United States)

    Koutentakis, Konstantinos; Rosales-Statkus, María Elena; Hoyos, Juan; Fernández-Balbuena, Sonia; Ruiz, Mónica; Agustí, Cristina; de la Fuente, Luis; Belza, María José

    2016-07-08

    Shortly after the approval of an over-the-counter HIV self-test in the US, we conducted a study to estimate the proportion of men who have sex with men (MSM) in Spain who knew that unauthorized HIV self-tests could be purchased online, and the proportion that had already used these tests, as well as their socio-demographic and behavioural correlates. Between September 2012 and February 2013, MSM users of gay dating websites were invited to complete an online questionnaire. We calculated estimates of the knowledge and use of unauthorized HIV self-testing and assessed the associated factors by rare event logit regression models. Among 8620 participants, 4.2 % (95 % CI:3.8-4.6) knew they could buy an unauthorized HIV self-test kit online, and 12.7 % (95 % CI:12.0-13.4) thought that such a test might exist, although they had never seen one. Only 0.7 % (95 % CI:0.5-0.9) had ever self-tested. In the multivariable analysis, knowledge of online availability of self-tests was associated with being a non-Latin American foreigner, having at least two previous HIV tests, intending to test for HIV in the next year, and knowing about U.S. approval of self-testing. Ever-use of HIV self-testing was associated with being over 34 years of age, living outside Spain during the last 12 months, and knowing about U.S. approval of self-testing. Both knowledge and use of unauthorized HIV self-testing among MSM in Spain was very low among HIV negative or untested MSM in Spain. The recent approval in the United Kingdom and France might increase the number of MSM seeking such testing and possibly using unauthorized test kits not meeting quality standards.

  20. Embryonic and foetal Islet-1 positive cells in human hearts are also positive to c-Kit

    Directory of Open Access Journals (Sweden)

    C. Serradifalco

    2011-12-01

    Full Text Available During embryogenesis, the mammalian heart develops from a primitive heart tube originating from two bilateral primary heart fields located in the lateral plate mesoderm. Cells belongings to the pre-cardiac mesoderm will differentiate into early cardiac progenitors, which express early transcription factors which are also common to the Isl-1 positive cardiac progenitor cells isolated from the developing pharyngeal mesoderm and the foetal and post-natal mice hearts. A second population of cardiac progenitor cells positive to c-Kit has been abundantly isolated from adult hearts. Until now, these two populations have been considered two different sets of progenitor cells present in the heart in different stages of an individual life. In the present study we collected embryonic, foetal and infant hearts, and we tested the hypotheses that c-Kit positive cells, usually isolated from the adult heart, are also present in the intra-uterine life and persist in the adult heart after birth, and that foetal Isl-1 positive cells are also positive to c-Kit. Using immunohistochemistry we studied the temporal distribution of Isl-1 positive and c-Kit/CD105 double positive cells, and by immunofluorescence and confocal analysis we studied the co-localization of c-Kit and Isl-1 positive cells. The results indicated that cardiomyocytes and interstitial cells were positive for c-Kit from the 9th to the 19th gestational week, that cells positive for both c-Kit and CD105 appeared in the interstitium at the 17th gestational week and persisted in the postnatal age, and that the Isl-1 positive cells were a subset of the c-Kit positive population.

  1. Inhibition of c-Kit signaling is associated with reduced heat and cold pain sensitivity in humans.

    Science.gov (United States)

    Ceko, Marta; Milenkovic, Nevena; le Coutre, Philipp; Westermann, Jörg; Lewin, Gary R

    2014-07-01

    The tyrosine kinase receptor c-Kit is critically involved in the modulation of nociceptive sensitivity in mice. Ablation of the c-Kit gene results in hyposensitivity to thermal pain, whereas activation of c-Kit produces hypersensitivity to noxious heat, without altering sensitivity to innocuous mechanical stimuli. In this study, we investigated the role of c-Kit signaling in human pain perception. We hypothesized that subjects treated with Imatinib or Nilotinib, potent inhibitors of tyrosine kinases including c-Kit but also Abl1, PDFGFRα, and PDFGFRβ, that are used to treat chronic myeloid leukemia (CML), would experience changes in thermal pain sensitivity. We examined 31 asymptomatic CML patients (14 male and 17 female) receiving Imatinib/Nilotinib treatment and compared them to 39 age- and sex-matched healthy controls (12 male and 27 female). We used cutaneous heat and cold stimulation to test normal and noxious thermal sensitivity, and a grating orientation task to assess tactile acuity. Thermal pain thresholds were significantly increased in the Imatinib/Nilotinib-treated group, whereas innocuous thermal and tactile thresholds were unchanged compared to those in the control group. In conclusion, our findings suggest that the biological effects of c-Kit inhibition are comparable in mice and humans in that c-Kit activity is required to regulate thermal pain sensitivity but does not affect innocuous thermal and mechanical sensation. The effect on experimental heat pain observed in our study is comparable to those of several common analgesics; thus modulation of the c-Kit pathway can be used to specifically modulate noxious heat and cold sensitivity in humans. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  2. Spotting and validation of a genome wide oligonucleotide chip with duplicate measurement of each gene

    International Nuclear Information System (INIS)

    Thomassen, Mads; Skov, Vibe; Eiriksdottir, Freyja; Tan, Qihua; Jochumsen, Kirsten; Fritzner, Niels; Brusgaard, Klaus; Dahlgaard, Jesper; Kruse, Torben A.

    2006-01-01

    The quality of DNA microarray based gene expression data relies on the reproducibility of several steps in a microarray experiment. We have developed a spotted genome wide microarray chip with oligonucleotides printed in duplicate in order to minimise undesirable biases, thereby optimising detection of true differential expression. The validation study design consisted of an assessment of the microarray chip performance using the MessageAmp and FairPlay labelling kits. Intraclass correlation coefficient (ICC) was used to demonstrate that MessageAmp was significantly more reproducible than FairPlay. Further examinations with MessageAmp revealed the applicability of the system. The linear range of the chips was three orders of magnitude, the precision was high, as 95% of measurements deviated less than 1.24-fold from the expected value, and the coefficient of variation for relative expression was 13.6%. Relative quantitation was more reproducible than absolute quantitation and substantial reduction of variance was attained with duplicate spotting. An analysis of variance (ANOVA) demonstrated no significant day-to-day variation

  3. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1977-01-01

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. The techniques may be of interest to hospital radiopharmacy personnel as many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration. Manufacturers of kits may also be interested in learning of the analytical methods used in the assessment of their products. (auth)

  4. Expression of c-kit in common benign and malignant breast lesions.

    Science.gov (United States)

    Kondi-Pafiti, Agatha; Arkadopoulos, Nikolaos; Gennatas, Constantinos; Michalaki, Vassiliki; Frangou-Plegmenou, Matrona; Chatzipantelis, Paschalis

    2010-01-01

    c-kit (CD117) is a transmembrane tyrosine kinase that acts as a type III receptor for mast cell growth factor. In recent years, the role of c-kit in the development of preinvasive and invasive breast carcinomas has been investigated. The aim of our study was to detect c-kit expression in the entire spectrum of common benign and malignant breast lesions in correlation with a well-studied myoepithelial or stem-cell like marker (p63). We evaluated 270 cases of benign and malignant breast lesions including fibrocystic disease, fibroadenoma, sclerosing adenosis, atypical ductal hyperplasia, ductal/lobular carcinoma in situ, and ductal/lobular/mixed type carcinoma. C-kit staining was evaluated in the cytoplasm/cell membrane in epithelial and myoepithelial cells and p63 in the nuclei of myoepithelial cells. c-kit was highly expressed (85.3%) in benign lesions (fibrocystic disease, sclerosing adenosis, fibroadenoma), and p63 expression was 95.5% in the aforementioned lesions. c-kit distribution in preinvasive and invasive lesions was as follows: ductal/lobular carcinoma in-situ, 43%/35%; ductal/lobular carcinoma, 36%/39%; and mixed type carcinoma, 20%. c-kit was highly expressed in myofibroblast/fibroblast cells only in grade III ductal/lobular carcinomas. c-kit was totally absent in stromal cells in benign lesions and in situ carcinomas whereas expression was weak in grade I and II carcinomas. Combined overexpression of c-kit and p63 is indicative of benign breast lesions. In contrast, there is reduced expression of c-kit in in situ and invasive breast carcinomas, with simultaneous overexpression in the stromal cells. This suggests that c-kit may play a role in breast cancer progression.

  5. The six-spot-step test - a new method for monitoring walking ability in patients with chronic inflammatory polyneuropathy

    DEFF Research Database (Denmark)

    Kreutzfeldt, Melissa; Jensen, Henrik B; Ravnborg, Mads

    2017-01-01

    OBJECTIVE: To evaluate whether the Six-Spot-Step-Test (SSST) is more suitable for monitoring walking ability in patients with chronic inflammatory polyneuropathy than the Timed-25-Foot-Walking test (T25FW). METHOD: In the SSST, participants have to walk as quickly as possible across a field...... of effect size, standardized response means and relative efficiency. Both ambulation tests correlated moderately to PGIC. CONCLUSION: The SSST may be superior to the T25FW in terms of dynamic range, floor effect and responsiveness which makes the SSST a possible alternative for monitoring walking ability...

  6. Feasibility of fractionating MIBI cold kits for cost reduction

    Energy Technology Data Exchange (ETDEWEB)

    Penglis, S.; Tsopelas, C. [Royal Adelaide Hospital. SA (Australia)

    1998-06-01

    Full text: Recently {sup 99m}Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of {sup 99m}Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N{sub 2} atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  7. Feasibility of fractionating MIBI cold kits for cost reduction

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1998-01-01

    Full text: Recently 99m Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of 99m Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N 2 atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  8. The Classroom-Friendly ABO Blood Types Kit: Blood Agglutination Simulation

    Science.gov (United States)

    Arnold, Savittree Rochanasmita; Kruatong, Tussatrin; Dahsah, Chanyah; Suwanjinda, Duongdearn

    2012-01-01

    The classroom-friendly ABO blood type kit was developed by combining advantages of modelling and a simulation laboratory to teach the topics of ABO blood types and blood transfusion. Teachers can easily simulate the agglutination reaction on a blood type testing plate in the classroom, and show the students how this reaction occurs by using the…

  9. Results of quality control studies of technetium 99m labelled radiopharmaceuticals prepared from kits

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1978-01-01

    This report summarizes the results of quality control studies of Tc 99m labelled normal serum albumin and macro-aggregated albumin radiopharmaceuticals prepared from commercially available kits. It includes all analyses performed since the inception of the program in 1976 until the end of 1977. The results presented herein were obtained through the application of various in vitro tests and animal (mouse) bio-distribution studies. It is hoped that a similar report will be published annually for the benefit of hospital nuclear medicine departments and kit manufacturers. (auth)

  10. Antigen-induced cytokine and chemokine release test for tuberculosis infection using adsorption of stimulated whole blood on filter paper and multiplex analysis

    DEFF Research Database (Denmark)

    Skogstrand, Kristin; Thysen, Anna H; Jørgensen, Charlotte S

    2012-01-01

    the spotting technique can make it suitable for use in locations without facilities like a centrifuge and a refrigerator. Materials and methods: Samples from 22 individuals undergoing screening for MTI and 10 healthy controls were incubated, centrifuged and IFN-γ measured by Enzyme-linked immunosorbent assay...... (ELISA), as described in the kit insert. In parallel, activated blood was spotted on filter paper (Schleicher & Schuell) and dried. The dried blood spot samples were analysed for 21 inflammatory markers with an in-house assay based on Luminex technology. Results: Our multiplex measurements...

  11. Nociceptive tuning by stem cell factor/c-Kit signaling.

    Science.gov (United States)

    Milenkovic, Nevena; Frahm, Christina; Gassmann, Max; Griffel, Carola; Erdmann, Bettina; Birchmeier, Carmen; Lewin, Gary R; Garratt, Alistair N

    2007-12-06

    The molecular mechanisms regulating the sensitivity of sensory circuits to environmental stimuli are poorly understood. We demonstrate here a central role for stem cell factor (SCF) and its receptor, c-Kit, in tuning the responsiveness of sensory neurons to natural stimuli. Mice lacking SCF/c-Kit signaling displayed profound thermal hypoalgesia, attributable to a marked elevation in the thermal threshold and reduction in spiking rate of heat-sensitive nociceptors. Acute activation of c-Kit by its ligand, SCF, resulted in a reduced thermal threshold and potentiation of heat-activated currents in isolated small-diameter neurons and thermal hyperalgesia in mice. SCF-induced thermal hyperalgesia required the TRP family cation channel TRPV1. Lack of c-Kit signaling during development resulted in hypersensitivity of discrete mechanoreceptive neuronal subtypes. Thus, c-Kit can now be grouped with a small family of receptor tyrosine kinases, including c-Ret and TrkA, that control the transduction properties of sensory neurons.

  12. Studies of an alpha-fetoprotein assay using dry blood-spot samples to be used for the detection of fetal neural tube defects.

    Science.gov (United States)

    Wong, P Y; Mee, A V; Doran, T A

    1982-06-01

    We modified the Pharmacia serum alpha-fetoprotein (AFP) kit to enable its use with dry blood-spots on filter paper. Reference values were established for blood from 253 women in the 16th to 18th weeks of gestation. The result by the present technique in a woman with a confirmed anencephalic fetus was elevated, and in agreement with the results of AFP assays in serum and amniotic fluid. Blood AFP was stable on dried filter paper sent by mail.

  13. Transitional–turbulent spots and turbulent–turbulent spots in boundary layers

    Science.gov (United States)

    Wu, Xiaohua; Moin, Parviz; Wallace, James M.; Skarda, Jinhie; Lozano-Durán, Adrián; Hickey, Jean-Pierre

    2017-01-01

    Two observations drawn from a thoroughly validated direct numerical simulation of the canonical spatially developing, zero-pressure gradient, smooth, flat-plate boundary layer are presented here. The first is that, for bypass transition in the narrow sense defined herein, we found that the transitional–turbulent spot inception mechanism is analogous to the secondary instability of boundary-layer natural transition, namely a spanwise vortex filament becomes a Λ vortex and then, a hairpin packet. Long streak meandering does occur but usually when a streak is infected by a nearby existing transitional–turbulent spot. Streak waviness and breakdown are, therefore, not the mechanisms for the inception of transitional–turbulent spots found here. Rather, they only facilitate the growth and spreading of existing transitional–turbulent spots. The second observation is the discovery, in the inner layer of the developed turbulent boundary layer, of what we call turbulent–turbulent spots. These turbulent–turbulent spots are dense concentrations of small-scale vortices with high swirling strength originating from hairpin packets. Although structurally quite similar to the transitional–turbulent spots, these turbulent–turbulent spots are generated locally in the fully turbulent environment, and they are persistent with a systematic variation of detection threshold level. They exert indentation, segmentation, and termination on the viscous sublayer streaks, and they coincide with local concentrations of high levels of Reynolds shear stress, enstrophy, and temperature fluctuations. The sublayer streaks seem to be passive and are often simply the rims of the indentation pockets arising from the turbulent–turbulent spots. PMID:28630304

  14. Transitional-turbulent spots and turbulent-turbulent spots in boundary layers.

    Science.gov (United States)

    Wu, Xiaohua; Moin, Parviz; Wallace, James M; Skarda, Jinhie; Lozano-Durán, Adrián; Hickey, Jean-Pierre

    2017-07-03

    Two observations drawn from a thoroughly validated direct numerical simulation of the canonical spatially developing, zero-pressure gradient, smooth, flat-plate boundary layer are presented here. The first is that, for bypass transition in the narrow sense defined herein, we found that the transitional-turbulent spot inception mechanism is analogous to the secondary instability of boundary-layer natural transition, namely a spanwise vortex filament becomes a [Formula: see text] vortex and then, a hairpin packet. Long streak meandering does occur but usually when a streak is infected by a nearby existing transitional-turbulent spot. Streak waviness and breakdown are, therefore, not the mechanisms for the inception of transitional-turbulent spots found here. Rather, they only facilitate the growth and spreading of existing transitional-turbulent spots. The second observation is the discovery, in the inner layer of the developed turbulent boundary layer, of what we call turbulent-turbulent spots. These turbulent-turbulent spots are dense concentrations of small-scale vortices with high swirling strength originating from hairpin packets. Although structurally quite similar to the transitional-turbulent spots, these turbulent-turbulent spots are generated locally in the fully turbulent environment, and they are persistent with a systematic variation of detection threshold level. They exert indentation, segmentation, and termination on the viscous sublayer streaks, and they coincide with local concentrations of high levels of Reynolds shear stress, enstrophy, and temperature fluctuations. The sublayer streaks seem to be passive and are often simply the rims of the indentation pockets arising from the turbulent-turbulent spots.

  15. Spotted star mapping by light curve inversion: Tests and application to HD 12545

    Science.gov (United States)

    Kolbin, A. I.; Shimansky, V. V.

    2013-06-01

    A code for mapping the surfaces of spotted stars is developed. The concept of the code is to analyze rotational-modulated light curves. We simulate the process of reconstruction for the star surface and the results of simulation are presented. The reconstruction atrifacts caused by the ill-posed nature of the problem are deduced. The surface of the spotted component of system HD 12545 is mapped using the procedure.

  16. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    Science.gov (United States)

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  17. Expression of proto-oncogene KIT is up-regulated in subset of human meningiomas

    Directory of Open Access Journals (Sweden)

    Saini Masum

    2012-06-01

    Full Text Available Abstract Background KIT is a proto-oncogene involved in diverse neoplastic processes. Aberrant kinase activity of the KIT receptor has been targeted by tyrosine kinase inhibitor (TKI therapy in different neoplasias. In all the earlier studies, KIT expression was reported to be absent in meningiomas. However, we observed KIT mRNA expression in some meningioma cases. This prompted us to undertake its detailed analyses in meningioma tissues resected during 2008–2009. Methods Tumor tissues and matched peripheral blood samples collected from meningioma patients were used for detailed molecular analyses. KIT expression was ascertained immunohistochemically and validated by immunoblotting. KIT and KITLG transcript levels were discerned by reverse transcription quantitative real-time PCR (RT-qPCR. Similarly, KIT amplification and allele loss were assessed by quantitative real-time (qPCR and validated by fluorescence in situ hybridization (FISH on the neoplastic tissues. Possible alterations of the gene at the nucleotide level were analyzed by sequencing. Results Contrary to earlier reports, KIT expression, was detected immunohistochemically in 20.6% meningioma cases (n = 34. Receptor (KIT and ligand (KITLG transcripts monitored by RT-qPCR were found to co-express (p = 0.048 in most of the KIT immunopositive tumors. 1/7 KIT positive meningiomas showed allele loss corroborated by reduced FISH signal in the corresponding neoplastic tissue. Sequence analysis of KIT showed M541L substitution in exon 10, in one of the immunopositive cases. However, its biological consequence remains to be uncovered. Conclusions This study clearly demonstrates KIT over-expression in the human meningiomas. The data suggest that up-regulated KIT transcription (p  0.05, is a likely mechanism responsible for altered KIT expression. Thus, KIT is a potential candidate for detailed investigation in the context of meningioma pathogenesis.

  18. Expression of proto-oncogene KIT is up-regulated in subset of human meningiomas

    International Nuclear Information System (INIS)

    Saini, Masum; Jha, Ajaya Nand; Abrari, Andleeb; Ali, Sher

    2012-01-01

    KIT is a proto-oncogene involved in diverse neoplastic processes. Aberrant kinase activity of the KIT receptor has been targeted by tyrosine kinase inhibitor (TKI) therapy in different neoplasias. In all the earlier studies, KIT expression was reported to be absent in meningiomas. However, we observed KIT mRNA expression in some meningioma cases. This prompted us to undertake its detailed analyses in meningioma tissues resected during 2008–2009. Tumor tissues and matched peripheral blood samples collected from meningioma patients were used for detailed molecular analyses. KIT expression was ascertained immunohistochemically and validated by immunoblotting. KIT and KITLG transcript levels were discerned by reverse transcription quantitative real-time PCR (RT-qPCR). Similarly, KIT amplification and allele loss were assessed by quantitative real-time (qPCR) and validated by fluorescence in situ hybridization (FISH) on the neoplastic tissues. Possible alterations of the gene at the nucleotide level were analyzed by sequencing. Contrary to earlier reports, KIT expression, was detected immunohistochemically in 20.6% meningioma cases (n = 34). Receptor (KIT) and ligand (KITLG) transcripts monitored by RT-qPCR were found to co-express (p = 0.048) in most of the KIT immunopositive tumors. 1/7 KIT positive meningiomas showed allele loss corroborated by reduced FISH signal in the corresponding neoplastic tissue. Sequence analysis of KIT showed M541L substitution in exon 10, in one of the immunopositive cases. However, its biological consequence remains to be uncovered. This study clearly demonstrates KIT over-expression in the human meningiomas. The data suggest that up-regulated KIT transcription (p < 0.001), instead of gene amplification (p > 0.05), is a likely mechanism responsible for altered KIT expression. Thus, KIT is a potential candidate for detailed investigation in the context of meningioma pathogenesis

  19. Mapping Sensory Spots for Moderate Temperatures on the Back of Hand.

    Science.gov (United States)

    Yang, Fan; Chen, Guixu; Zhou, Sikai; Han, Danhong; Xu, Jingjing; Xu, Shengyong

    2017-12-04

    Thermosensation with thermoreceptors plays an important role in maintaining body temperature at an optimal state and avoiding potential damage caused by harmful hot or cold environmental temperatures. In this work, the locations of sensory spots for sensing moderate temperatures of 40-50 °C on the back of the hands of young Chinese people were mapped in a blind-test manner with a thermal probe of 1.0 mm spatial resolution. The number of sensory spots increased along with the testing temperature; however, the surface density of sensory spots was remarkably lower than those reported previously. The locations of the spots were irregularly distributed and subject-dependent. Even for the same subject, the number and location of sensory spots were unbalanced and asymmetric between the left and right hands. The results may offer valuable information for designing artificial electronic skin and wearable devices, as well as for clinical applications.

  20. TEST KIT FOR THE DETECTION AND GENOTYPING OF HIGHLY PATHOGENIC INFLUENZA VIRUS A H5N1 BY REAL-TIME POLYMERASE CHAIN REACTION

    Directory of Open Access Journals (Sweden)

    S. V. Stepaniuk

    2014-06-01

    Full Text Available Results of the annual monitoring of epizooties indicate that highly pathogenic HPAI/H5N1 avian influenza widely circulated in Eurasian region. Over a period of 2010–2013 years more than 165 cases of outbreaks in 14 countries were found out. Ukraine became one of the first countries in Europe where in Autonomous Republic of Crimea in October 2005 outbreak of avian epizootic with HPAI/H5N1 was documented and until February 2008 more than 236,000 poultry were killed. Since then the question of monitoring of infected both migrating birds and poultry in places of cross contact in Ukraine remains of high priority. The test system is developed for identification and genotyping A H5N1 on three genes (M, H5 and N1 HPAI/H5N1 in real-time mode for polymerase chain reaction. Test kit capacity to detect HPAI/h5n1avian influenza virus and differentiate it from the other viral infection agents of birds and animals were studied by testing of HPAI/H5N1 virus isolated during mass infection outbreak in Crimea in 2005 and cultural specimens of other viral pathogens. It was established that the «DIA Real Avian Influenza» test kit was capable to detect RNA influenza A virus of high pathogenic H5N1 strains having high sensitivity (100% while RNA of the Crimean HPAI/H5N1 isolate studying and specificity (100% while RNA viruses of Newcastle birds disease, fowl powershift, syndrome of drop in egg production and horse influenza studying.

  1. 21 CFR 866.2480 - Quality control kit for culture media.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for culture media. 866.2480... control kit for culture media. (a) Identification. A quality control kit for culture media is a device...-dried, viable microorganism, intended for medical purposes to determine if a given culture medium is...

  2. Supply kits for antenatal and childbirth care: a systematic review.

    Science.gov (United States)

    Aleman, Alicia; Tomasso, Giselle; Cafferata, María Luisa; Colomar, Mercedes; Betran, Ana Pilar

    2017-12-13

    It is critical to increase the uptake of interventions proven to be effective to improve maternal and perinatal outcomes. Supply kits have been suggested to be a feasible strategy designed to ensure timely availability and effective follow-up of care. We conducted a systematic review to summarize the evidence on the uptake, effectiveness and safety of supply kits for maternal care. MEDLINE, the Cochrane Pregnancy and Childbirth Group's Trials Register, Campbell Collaboration, Lilacs, Embase and unpublished studies were searched. Studies that reported the efficacy, safety and use of supply kits for maternal healthcare were eligible. Participants were pregnant women or in childbirth. Supply kits were defined as a collection of medicines, supplies or instruments packaged together with the aim of conducting a healthcare task. Two reviewers independently performed the screening, data extraction, and methodological and quality assessment. 24 studies were included: 4 of them were systematic reviews and 20 primary studies. Eighteen studies evaluated a so-called "clean delivery kit". In all but two studies, the kits were used by more than half of the participants. A meta-analysis was deemed inappropriate due to the heterogeneity in study design, in the components of the interventions implemented, in the content of the kits, and in outcomes. Nine studies assessed neonatal outcomes and found statistically significant reductions in cord infection, sepsis and tetanus-related mortality in the intervention group. Three studies showed evidence of reduced neonatal mortality (OR 0.52, 0.60 and 0.71) with statistically significant confidence intervals in all cases. Four studies reported odd ratios for maternal mortality, but only one showed evidence of a statistically significant decrease in this outcome but it was ascribed to hand washing prior to childbirth and not with the use of kits. This review suggests potential benefits in the use of supply kits to improve maternal and

  3. Assessment of Nugget Size of Spot Weld using Neutron Radiography

    Directory of Open Access Journals (Sweden)

    Triyono

    2011-08-01

    Full Text Available Resistance spot welding (RSW has been widely used for many years in the fabrication of car body structures, mainly due to the cost and time considerations. The weld quality as well as the nugget size is an issue in various manufacturing and processes due to the strong link between the weld quality and safety. It has led to the development of various destructive and non-destructive tests for spot welding such as peel testing, ultrasonic inspections, digital shearography, and infrared thermography. However, such methods cannot show spot weld nugget visually and the results are very operator’s skill dependent. The present work proposes a method to visualize the nugget size of spot welds using neutron radiography. Water, oil and various concentrations of gadolinium oxide-alcohol mixture were evaluated as a contrast media to obtain the best quality of radiography. Results show that mixture of 5 g gadolinium oxide (Gd2O3 in 25 ml alcohol produces the best contrast. It provides the possibility to visualize the shape and size of the nugget spot weld. Furthermore, it can discriminate between nugget and corona bond. The result of neutron radiography evaluation shows reasonable agreement with that of destructive test.

  4. The Quality Lighting Teaching Kit: enlightening our future

    Science.gov (United States)

    Walker, Constance E.; Pompea, Stephen M.

    2016-09-01

    The U.S. National Optical Astronomy Observatory's Education and Public Outreach group has produced a Quality Lighting Teaching (QLT) Kit, as an outcome of the International Year of Light 2015. The kits are designed around problem-based learning scenarios. The kit's six activities allow students to address real lighting problems that relate to wildlife, sky glow, aging eyes, energy consumption, safety, and light trespass. The activities are optimized for 11-14 year olds but can be expanded to younger and older. Most of the activities can be done within in a few minutes with the exception of the Energy Activity. The activities can be done during class or afterschool and as stations (that the students rotate through) or as stand-alones (one at a time). All aspects of the program are as ready-for-use. Everything you need for the six activities is included in the kit. Tutorial videos (on the program's webpage) have been created on how to do the activities. They can be found on the webpage, www.noao.edu/education/qltkit.php. Fourteen Google+ Hangouts on Air have been offered, addressing questions on the activities and logistics. Assessments (in the form of pre- and post-surveys for the students and as post-surveys for the instructors) provide learning outcomes and improvements. Eighty-nine out of 100 kits have been distributed to SPIE, OSA, CIE, IDA and the IAU in 31 countries. The QLT Kit is a stepping-stone to bring awareness to the (younger) public on how quality lighting locally can redress issues like light pollution globally.

  5. Neutron Measurement Instrumentation Development at KIT for the European ITER TBM

    Energy Technology Data Exchange (ETDEWEB)

    Klix, A.; Fischer, U.; Raj, P.; Reimann, Th.; Szalkai, D.; Tian, K. [Association KIT-EURATOM, Karlsruhe Institute of Technology, D-76344 Eggenstein-Leopoldshafen (Germany); Angelone, M. [Associazione ENEA-EURATOM sulla Fusione, ENEA C.R., I-00044 Frascati (Italy); Gehre, D. [Technical University of Dresden, D-01069 Dresden (Germany); Lyoussi, A. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France)

    2015-07-01

    Fusion power reactors will rely on the internal production of the fuel tritium from lithium in the tritium breeding blanket. Test Blanket Modules (TBM) will be installed in ITER with the aim to investigate the nuclear performance of different breeding blanket designs. Currently there is no fully qualified nuclear instrumentation available for the measurement of neutron fluxes and tritium production rates which would be able to withstand the harsh environment conditions in the TBM such as high temperature (>400 deg. C) and, depending on the operation scenario, intense radiation levels. As partner of the European Consortium on Nuclear Data and Measurement Techniques in the framework of several F4E specific grants and contracts, KIT and ENEA have jointly studied the possibility to develop and test detectors suitable to operate in ITER-TBMs. Here we present an overview of ongoing work on three types of neutron flux monitors under development for the TBMs with focus on the KIT activities. A neutron activation system (NAS) with pneumatic sample transport could provide absolute neutron flux measurements in selected positions. A test system for investigating activation materials with short half-lives was constructed at the DT neutron generator laboratory of Technical University of Dresden to investigate the neutronics aspects. Several irradiations have been performed with focus on the simultaneous measurement of the extracted activated probes. An engineering assessment of a TBM NAS in the conceptual design phase has been done which considered issues of design requirements and integration. Last but not least, a mechanical test bench is under construction at KIT which will address issues of driving the activation probes, solutions for loading the system etc. experimentally. Self-powered neutron detectors (SPND) are widely applied in fission reactor monitoring, and the commercially available SPNDs are sensitive to thermal neutrons. We are investigating novel materials for

  6. Performance of the Spot Vision Screener in Children Younger Than 3 Years of Age.

    Science.gov (United States)

    Forcina, Blake D; Peterseim, M Millicent; Wilson, M Edward; Cheeseman, Edward W; Feldman, Samuel; Marzolf, Amanda L; Wolf, Bethany J; Trivedi, Rupal H

    2017-06-01

    To evaluate the use of the Spot Vision Screener (Spot; Welch Allyn, Skaneateles Falls, New York, USA) for detection of amblyopia risk factors in children aged 6 months to 3 years, as defined by the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus. Reliability analysis. In this study, children seen from June 1, 2012, to April 30, 2016 were tested with the Spot during a routine visit. Enrolled children underwent a comprehensive eye examination including cycloplegic refraction and sensorimotor testing within 6 months of the testing date by a pediatric ophthalmologist masked to the Spot results. A total of 184 children were included. The Spot successfully obtained readings in 89.7% of patients. Compared with the ophthalmologist's examination, the Spot had an overall sensitivity of 89.8% and a specificity of 70.4%. The Spot achieved good sensitivity and specificity for detection of amblyopia risk factors in this young cohort, particularly in the older subgroup. Our data offer support for automated vision screening in young children. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Plasma spot welding of ferritic stainless steels

    International Nuclear Information System (INIS)

    Lesnjak, A.; Tusek, J.

    2002-01-01

    Plasma spot wedding of ferritic stainless steels studied. The study was focused on welding parameters, plasma and shieldings and the optimum welding equipment. Plasma-spot welded overlap joints on a 0.8 mm thick ferritic stainless steel sheet were subjected to a visual examination and mechanical testing in terms of tension-shear strength. Several macro specimens were prepared Plasma spot welding is suitable to use the same gas as shielding gas and as plasma gas , i. e. a 98% Ar/2% H 2 gas mixture. Tension-shear strength of plasma-spot welded joint was compared to that of resistance sport welded joints. It was found that the resistance welded joints withstand a somewhat stronger load than the plasma welded joints due to a large weld sport diameter of the former. Strength of both types of welded joints is approximately the same. (Author) 32 refs

  8. Spotted inflation

    International Nuclear Information System (INIS)

    Matsuda, Tomohiro

    2010-01-01

    We describe new scenarios for generating curvature perturbations when inflaton (curvaton) has significant interactions. We consider a ''spot'', which arises from interactions associated with an enhanced symmetric point (ESP) on the trajectory. Our first example uses the spot to induce a gap in the field equation. We observe that the gap in the field equation may cause generation of curvature perturbation if it does not appear simultaneous in space. The mechanism is similar to the scenario of inhomogeneous phase transition. Then we observe that the spot interactions may initiate warm inflation in the cold Universe. Creation of cosmological perturbation is discussed in relation to the inflaton dynamics and the modulation associated with the spot interactions

  9. Liquid kit for preparation of 188rhenium-etidronate

    International Nuclear Information System (INIS)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    The aim of this study was the preparation of a liquid kit for radiolabeling of 188 Re-HEDP (hydroxyethylidene diphosphonate). 188 Re was obtained from alumina based 188 W/ 188 Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of 188 Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  10. World Disarmament Kit.

    Science.gov (United States)

    Woito, Robert, Ed.

    This kit presents a comprehensive introduction for students to arms control and disarmament issues. Included are copies of published and unpublished articles for each topic. Section I provides a self-survey to enable students to assess their own attitudes, values, and knowledge. The survey poses questions for which students select one of several…

  11. Reliability of copper based alloys for electric resistance spot welding

    International Nuclear Information System (INIS)

    Jovanovicj, M.; Mihajlovicj, A.; Sherbedzhija, B.

    1977-01-01

    Durability of copper based alloys (B-5 and B-6) for electric resistance spot-welding was examined. The total amount of Be, Ni and Zr was up to 2 and 1 wt.% respectively. Good durability and satisfactory quality of welded spots were obtained in previous laboratory experiments carried out on the fixed spot-welding machine of an industrial type (only B-5 alloy was examined). Electrodes made of both B-5 and B-6 alloy were tested on spot-welding grips and fixed spot-welding machines in Tvornica automobila Sarajevo (TAS). The obtained results suggest that the durability of electrodes made of B-5 and B-6 alloys is more than twice better than of that used in TAS

  12. Preparation of acid-base bifunctional mesoporous KIT-6 (KIT: Korea Advanced Institute of Science and Technology) and its catalytic performance in Knoevenagel reaction

    International Nuclear Information System (INIS)

    Xu, Ling; Wang, Chunhua; Guan, Jingqi

    2014-01-01

    Acid-base bifunctional mesoporous catalysts Al-KIT-6-NH 2 containing different aluminum content have been synthesized through post synthetic grafting method. The materials were characterized by X-ray diffraction (XRD), scanning electron micrographs (SEM), transmission electron micrographs (TEM), Fourier-transform infrared spectroscopy (FTIR), IR spectra of pyridine adsorption, NH 3 -TPD and TG analysis. The characterization results indicated that the pore structure of KIT-6 was well kept after the addition of aluminum and grafting of aminopropyl groups. The acid amount of Al-KIT-6 increased with enhancing aluminum content. Catalytic results showed that weak acid and weak base favor the Knoevenagel reaction, while catalysts with strong acid and weak base exhibited worse catalytic behavior. - Graphical abstract: The postulated steps of mechanism for the acid-base catalyzed process are as follows: (1) the aldehyde gets activated by the surface acidic sites which allow the amine undergoes nucleophilic to attack the carbonyl carbon of benzaldehyde. (2) Water is released in the formation of imine intermediate. (3) The ethyl cyanoacetate reacts with the intermediate. (4) The benzylidene ethyl cyanoacetate is formed and the amine is regenerated. - Highlights: • KIT-6 and Al-KIT-6-NH 2 with different Si/Al ratios has been successfully prepared. • 79.4% Yield was obtained over 46-Al-KIT-6-NH 2 within 20 min in Knoevenagel reaction. • Low Al-content Al-KIT-6-NH 2 shows better catalytic stability than high Al-content catalysts. • There is acid-base synergistic effect in Knoevenagel reaction

  13. Preparation of acid-base bifunctional mesoporous KIT-6 (KIT: Korea Advanced Institute of Science and Technology) and its catalytic performance in Knoevenagel reaction

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ling [College of Chemistry and Chemical Engineering, Inner Mongolia University for Nationalities, Tongliao 028000 (China); Wang, Chunhua [Key Laboratory of Surface and Interface Chemistry of Jilin Province, College of Chemistry, Jilin University, Changchun 130023 (China); Guan, Jingqi, E-mail: guanjq@jlu.edu.cn [Key Laboratory of Surface and Interface Chemistry of Jilin Province, College of Chemistry, Jilin University, Changchun 130023 (China)

    2014-05-01

    Acid-base bifunctional mesoporous catalysts Al-KIT-6-NH{sub 2} containing different aluminum content have been synthesized through post synthetic grafting method. The materials were characterized by X-ray diffraction (XRD), scanning electron micrographs (SEM), transmission electron micrographs (TEM), Fourier-transform infrared spectroscopy (FTIR), IR spectra of pyridine adsorption, NH{sub 3}-TPD and TG analysis. The characterization results indicated that the pore structure of KIT-6 was well kept after the addition of aluminum and grafting of aminopropyl groups. The acid amount of Al-KIT-6 increased with enhancing aluminum content. Catalytic results showed that weak acid and weak base favor the Knoevenagel reaction, while catalysts with strong acid and weak base exhibited worse catalytic behavior. - Graphical abstract: The postulated steps of mechanism for the acid-base catalyzed process are as follows: (1) the aldehyde gets activated by the surface acidic sites which allow the amine undergoes nucleophilic to attack the carbonyl carbon of benzaldehyde. (2) Water is released in the formation of imine intermediate. (3) The ethyl cyanoacetate reacts with the intermediate. (4) The benzylidene ethyl cyanoacetate is formed and the amine is regenerated. - Highlights: • KIT-6 and Al-KIT-6-NH{sub 2} with different Si/Al ratios has been successfully prepared. • 79.4% Yield was obtained over 46-Al-KIT-6-NH{sub 2} within 20 min in Knoevenagel reaction. • Low Al-content Al-KIT-6-NH{sub 2} shows better catalytic stability than high Al-content catalysts. • There is acid-base synergistic effect in Knoevenagel reaction.

  14. Design of a cost-effective laser spot tracker

    Science.gov (United States)

    Artan, Göktuǧ Gencehan; Sari, Hüseyin

    2017-05-01

    One of the most important aspects of guided systems is detection. The most convenient detection in the sense of precision can be achieved with a laser spot tracker. This study deals with a military grade, high performance and cost-effective laser spot tracker for a guided system. The aim is to develop a high field of view system that will detect a laser spot from a distance of 3 kilometers in which the target is designated from 3 kilometers with a laser. The study basically consists of the system design, modeling, producing and the conducting performance tests of the whole system.

  15. Bier spots

    OpenAIRE

    Ahu Yorulmaz,; Seray Kulcu Cakmak; Esra Ar?; Ferda Artuz

    2015-01-01

    Also called as physiologic anemic macules, Bier spots are small, hypopigmented irregularly shaped macules against a background of diffuse erythema, which creates an appearance of speckled vascular mottling of the skin. Bier spots most commonly appear on distal portions of the limbs though there are case reports describing diffuse involvement, which also affect trunk and mucous membranes of the patient. Although the exact pathophysiological mechanisms underlying Bier spots still need to be elu...

  16. Evaluation of an immunodot test to manage white spot syndrome virus (WSSV) during cultivation of the giant tiger shrimp Penaeus monodon

    Digital Repository Service at National Institute of Oceanography (India)

    Patil, R.; Palaksha, K.J.; Anil, T.M.; Guruchannabasavanna; Patil, P.; Shankar, K.M.; Mohan, C.V.; Sreepada, R.A.

    A monoclonal antibody-based immunodot test was compared to a polymerase chain reaction (PCR) assay for managing white spot syndrome virus (WSSV) on shrimp farms at Kundapur and Kumta situated in Udupi and Uttar Kannada Districts, respectively...

  17. Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors

    International Nuclear Information System (INIS)

    Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma

    2006-01-01

    Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs

  18. Inter-laboratory assessment of a prototype multiplex kit for determination of recent HIV-1 infection.

    Directory of Open Access Journals (Sweden)

    Kelly A Curtis

    Full Text Available BACKGROUND: Accurate and reliable laboratory-based assays are needed for estimating HIV-1 incidence from cross-sectional samples. We recently described the development of a customized, HIV-1-specific Bio-Plex assay that allows for the measurement of HIV-specific antibody levels and avidity to multiple analytes for improved HIV-1 incidence estimates. METHODS: To assess intra- and inter-laboratory assay performance, prototype multiplex kits were developed and evaluated by three distinct laboratories. Longitudinal seroconversion specimens were tested in parallel by each laboratory and kit performance was compared to that of an in-house assay. Additionally, the ability of the kit to distinguish recent from long-term HIV-1 infection, as compared to the in-house assay, was determined by comparing the reactivity of known recent (infected 12 months drug naïve specimens. RESULTS: Although the range of reactivity for each analyte varied between the prototype kit and in-house assay, a measurable distinction in reactivity between recent and long-term specimens was observed with both assays in all three laboratories. Additionally, kit performance was consistent between all three laboratories. The intra-assay coefficient of variation (CV, between sample replicates for all laboratories, ranged from 0.5% to 6.1%. The inter-laboratory CVs ranged from 8.5% to 21.3% for gp160-avidity index (a and gp120-normalized mean fluorescent intensity (MFI value (n, respectively. CONCLUSION: We demonstrate the feasibility of producing a multiplex kit for measuring HIV antibody levels and avidity, with the potential for improved incidence estimates based on multi-analyte algorithms. The availability of a commercial kit will facilitate the transfer of technology among diverse laboratories for widespread assay use.

  19. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    Science.gov (United States)

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  20. Evaluation of the Coca-Cola company travel health kit.

    Science.gov (United States)

    Harper, Lynne A; Bettinger, Julie; Dismukes, Roberta; Kozarsky, Phyllis E

    2002-01-01

    The Coca-Cola travel health kit has been used for about one decade for international travelers and required evaluation to see if the items contained were appropriate for the employees. Two hundred thirty-four travelers were sampled and filled out a voluntary survey including questions about demographic information, travel history, and usage and value of the contents of the travel health kit. One hundred eighty-one surveys were returned; 65% of the respondents were male, and the majority of travelers were between the ages of 36 and 45 years. The most useful items were analgesics and medications used for gastrointestinal problems. In general, the items identified as being the least useful were those requiring specialized use by a medical practitioner, such as needles and syringes. Suggestions of items to be added to the kit included vitamins, cough drops, sleep aids, and eye drops. A surprising result that Coca-Cola employees expressed the desire for brand name rather than generic items. Evaluation of the Coca-Cola Company travel health kit revealed it to be very useful to most corporate travelers. Suggestions that were made will be taken into consideration in designing a new kit, and consideration is being given to whether a basic travel health kit should be provided to which travelers can add other items depending on their personal needs.

  1. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  2. Kit W-sh Mutation Prevents Cancellous Bone Loss during Calcium Deprivation.

    Science.gov (United States)

    Lotinun, Sutada; Suwanwela, Jaijam; Poolthong, Suchit; Baron, Roland

    2018-01-01

    Calcium is essential for normal bone growth and development. Inadequate calcium intake increases the risk of osteoporosis and fractures. Kit ligand/c-Kit signaling plays an important role in regulating bone homeostasis. Mice with c-Kit mutations are osteopenic. The present study aimed to investigate whether impairment of or reduction in c-Kit signaling affects bone turnover during calcium deprivation. Three-week-old male WBB6F1/J-Kit W /Kit W-v /J (W/W v ) mice with c-Kit point mutation, Kit W-sh /HNihrJaeBsmJ (W sh /W sh ) mice with an inversion mutation in the regulatory elements upstream of the c-Kit promoter region, and their wild-type controls (WT) were fed either a normal (0.6% calcium) or a low calcium diet (0.02% calcium) for 3 weeks. μCT analysis indicated that both mutants fed normal calcium diet had significantly decreased cortical thickness and cancellous bone volume compared to WT. The low calcium diet resulted in a comparable reduction in cortical bone volume and cortical thickness in the W/W v and W sh /W sh mice, and their corresponding controls. As expected, the low calcium diet induced cancellous bone loss in the W/W v mice. In contrast, W sh /W sh cancellous bone did not respond to this diet. This c-Kit mutation prevented cancellous bone loss by antagonizing the low calcium diet-induced increase in osteoblast and osteoclast numbers in the W sh /W sh mice. Gene expression profiling showed that calcium deficiency increased Osx, Ocn, Alp, type I collagen, c-Fms, M-CSF, and RANKL/OPG mRNA expression in controls; however, the W sh mutation suppressed these effects. Our findings indicate that although calcium restriction increased bone turnover, leading to osteopenia, the decreased c-Kit expression levels in the W sh /W sh mice prevented the low calcium diet-induced increase in cancellous bone turnover and bone loss but not the cortical bone loss.

  3. Single vial kit formulation for preparation of {sup 68}Ga-AMBA: a PET imaging agent for prostate cancers

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Usha; Mukherjee, Archana; Gamre, Naresh; Dash, Ashutosh [Isotope Applications and Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai (India); Sarma, Haladhar Dev [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-05-01

    This work was aimed at the kit formulation of a bombesin analog, AMBA, for potential use in imaging of prostate cancers after {sup 68}Ga labeling. Towards this aim, a kit was formulated in acetate buffer under aseptic conditions for labeling with {sup 68}Ga eluted from the nanoceria-PAN based {sup 68}Ge/{sup 68}Ga BARC generator. All the reaction parameters for optimum radiolabeling were standardized and the radiometal complexes were characterized by chromatography techniques. The kit formulations gave >95% radiolabeling yields consistently when tested up to two months. Pharmacokinetics of the radiolabeled peptide was studied in Swiss mice, which showed fast clearance of activity via renal route. (author)

  4. Insights from ecological niche modeling on the taxonomic distinction and niche differentiation between the black-spotted and red-spotted tokay geckoes (Gekko gecko).

    Science.gov (United States)

    Zhang, Yueyun; Chen, Chongtao; Li, Li; Zhao, Chengjian; Chen, Weicai; Huang, Yong

    2014-09-01

    The black-spotted tokay and the red-spotted tokay are morphologically distinct and have largely allopatric distributions. The black-spotted tokay is characterized by a small body size and dark skin with sundry spots, while the red-spotted tokay has a relatively large body size and red spots. Based on morphological, karyotypic, genetic, and distribution differences, recent studies suggested their species status; however, their classifications remain controversial, and additional data such as ecological niches are necessary to establish firm hypotheses regarding their taxonomic status. We reconstructed their ecological niches models using climatic and geographic data. We then performed niche similarity tests (niche identity and background tests) and point-based analyses to explore whether ecological differentiation has occurred, and whether such differences are sufficient to explain the maintenance of their separate segments of environmental ranges. We found that both niche models of the black- and the red-spotted tokay had a good fit and a robust performance, as indicated by the high area under the curve (AUC) values ("black" = 0.982, SD = ± 0.002, "red" = 0.966 ± 0.02). Significant ecological differentiation across the entire geographic range was found, indicating that the involvement of ecological differentiation is important for species differentiation. Divergence along the environmental axes is highly associated with climatic conditions, with isothermality being important for the "black" form, while temperature seasonality, precipitation of warmest quarter, and annual temperature range together being important for the "red" form. These factors are likely important factors in niche differentiation between the two forms, which result in morphological replacement. Overall, beside morphological and genetic differentiation information, our results contribute to additional insights into taxonomic distinction and niche differentiation between the black- and the red-spotted

  5. Data on quantification of signaling pathways activated by KIT and PDGFRA mutants

    Directory of Open Access Journals (Sweden)

    Christelle Bahlawane

    2016-12-01

    Full Text Available The present data are related to the article entitled “Insights into ligand stimulation effects on gastro-intestinal stromal tumors signaling” (C. Bahlawane, M. Schmitz, E. Letellier, K. Arumugam, N. Nicot, P.V. Nazarov, S. Haan, 2016 [1]. Constitutive and ligand-derived signaling pathways mediated by KIT and PDGFRA mutated proteins found in gastrointestinal stromal tumors (GIST were compared. Expression of mutant proteins was induced by doxycycline in an isogenic background (Hek293 cells. Kit was identified by FACS at the cell surface and found to be quickly degraded or internalized upon SCF stimulation for both Kit Wild type and Kit mutant counterparts. Investigation of the main activated pathways in GIST unraveled a new feature specific for oncogenic KIT mutants, namely their ability to be further activated by Kit ligand, the stem cell factor (scf. We were also able to identify the MAPK pathway as the most prominent target for a common inhibition of PDGFRA and KIT oncogenic signaling. Western blotting and micro-array analysis were applied to analyze the capacities of the mutant to induce an effective STATs response. Among all Kit mutants, only Kit Ex11 deletion mutant was able to elicit an effective STATs response whereas all PDGFRA were able to do so.

  6. ConKit: a python interface to contact predictions.

    Science.gov (United States)

    Simkovic, Felix; Thomas, Jens M H; Rigden, Daniel J

    2017-07-15

    Recent advances in protein residue contact prediction algorithms have led to the emergence of many new methods and a variety of file formats. We present ConKit , an open source, modular and extensible Python interface which allows facile conversion between formats and provides an interface to analyses of sequence alignments and sets of contact predictions. ConKit is available via the Python Package Index. The documentation can be found at http://www.conkit.org . ConKit is licensed under the BSD 3-Clause. hlfsimko@liverpool.ac.uk or drigden@liverpool.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  7. Personalized Thematic Kits

    Science.gov (United States)

    Bontrager, Sharon

    2010-01-01

    Teaching Spanish at the K-5 level is a passion of mine, and the author would like to share some of the practical applications that she finds most rewarding and effective. She has found enthusiastic response to the creation of detailed language learning kits that are rooted in storytelling, but expanded to include home-made board games,…

  8. How to define the tool kit for the corrective maintenance service? : a tool kit definition model under the service performance criterion

    NARCIS (Netherlands)

    Chen, Denise

    2009-01-01

    Currently, the rule of defining tool kits is varied and more engineer's aspects oriented. However, the decision of the tool kit's definition is a trade-off problem between the cost and the service performance. This project is designed to develop a model that can integrate the engineer's preferences

  9. Analytical techniques for the determination of radiochemical purity of radiopharmaceuticals prepared from kits. Pt. III

    International Nuclear Information System (INIS)

    McLean, J.R.; Rockwell, L.J.; Welsh, W.J.

    1982-01-01

    The evaluation of efficacy of commercially available kits used for the preparation of radiopharmaceuticals is one aspect of the Radiation Protection Bureau's radiopharmaceutical quality control program. This report describes some of the analytical methodology employed in the program. The techniques may be of interest to hospital radiopharmacy personnel since many of the tests can be performed rapidly and with a minimum of special equipment, thus enabling the confirmation of radiopharmaceutical purity prior to patient administration. Manufacturers of kits may also be interested in learning of the analytical methods used in the assessment of their products

  10. Over-the-counter human immunodeficiency virus self-test kits: time to explore their use for men who have sex with men in Brazil

    Directory of Open Access Journals (Sweden)

    Sheri A. Lippman

    2014-05-01

    Full Text Available Increasing access and frequency of human immunodeficiency virus testing are critical to stemming the epidemic. In Brazil's concentrated epidemic, human immunodeficiency virus prevalence in the men who have sex with men/transgender population far exceeds that in the general population, but testing rates fall below what is needed to ensure early detection and treatment. Over-the-counter human immunodeficiency virus self-testing kits, now available in stores in the U.S., have enormous potential to increase testing access and frequency and to facilitate early detection and treatment. With the advent of human immunodeficiency virus self-testing upon us, it is timely to engage the scientific community, government, and civil society in a dialog around how to best utilize this technology in Brazil. We summarize recent research on over-the-counter testing among men who have sex with men, raise potential questions and challenges to using self-tests, suggest implementation strategies, and outline a research agenda moving forward.

  11. Receptor tyrosine kinase (c-Kit inhibitors: a potential therapeutic target in cancer cells

    Directory of Open Access Journals (Sweden)

    Abbaspour Babaei M

    2016-08-01

    Full Text Available Maryam Abbaspour Babaei,1 Behnam Kamalidehghan,2,3 Mohammad Saleem,4–6 Hasniza Zaman Huri,1,7 Fatemeh Ahmadipour1 1Department of Pharmacy, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia; 2Department of Medical Genetics, National Institute of Genetic Engineering and Biotechnology (NIGEB, Shahrak-e Pajoohesh, 3Medical Genetics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran; 4Department of Urology, 5Department of Laboratory Medicine and Pathology, Masonic Cancer Center, University of Minnesota, 6Section of Molecular Therapeutics & Cancer Health Disparity, The Hormel Institute, Austin, MN, USA; 7Clinical Investigation Centre, University Malaya Medical Centre, Lembah Pantai, Kuala Lumpur, Malaysia Abstract: c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit

  12. Mutational status of EGFR and KIT in thymoma and thymic carcinoma.

    Science.gov (United States)

    Yoh, Kiyotaka; Nishiwaki, Yutaka; Ishii, Genichiro; Goto, Koichi; Kubota, Kaoru; Ohmatsu, Hironobu; Niho, Seiji; Nagai, Kanji; Saijo, Nagahiro

    2008-12-01

    This study was conducted to evaluate the prevalence of EGFR and KIT mutations in thymomas and thymic carcinomas as a means of exploring the potential for molecularly targeted therapy with tyrosine kinase inhibitors. Genomic DNA was isolated from 41 paraffin-embedded tumor samples obtained from 24 thymomas and 17 thymic carcinomas. EGFR exons 18, 19, and 21, and KIT exons 9, 11, 13, and 17, were analyzed for mutations by PCR and direct sequencing. Protein expression of EGFR and KIT was evaluated immunohistochemically. EGFR mutations were detected in 2 of 20 thymomas, but not in any of the thymic carcinomas. All of the EGFR mutations detected were missense mutations (L858R and G863D) in exon 21. EGFR protein was expressed in 71% of the thymomas and 53% of the thymic carcinomas. The mutational analysis of KIT revealed only a missense mutation (L576P) in exon 11 of one thymic carcinoma. KIT protein was expressed in 88% of the thymic carcinomas and 0% of the thymomas. The results of this study indicate that EGFR and KIT mutations in thymomas and thymic carcinomas are rare, but that many of the tumors express EGFR or KIT protein.

  13. Energy is not Coffee. An assessment of blind spots on energy spot-markets

    International Nuclear Information System (INIS)

    Jepma, C.J.; Spijker, E.; Van der Gaast, W.; De Jong, F.; Overmars, P.

    2006-01-01

    This study was to be the first in a series of studies on the title subject. It specifically focuses on the differences and similarities with a number of other spot-markets and aims to frame the energy spot markets and their potential development into a broader perspective. Main conclusion is that energy spot-markets differ from several other physical and non-physical spot-markets in many ways. This implies that 'perfect' energy spot-markets may inherently be (much) less perfect than other spot-markets that have approximated the stage of theoretical perfection

  14. Simulation of the Focal Spot of the Accelerator Bremsstrahlung Radiation

    Science.gov (United States)

    Sorokin, V.; Bespalov, V.

    2016-06-01

    Testing of thick-walled objects by bremsstrahlung radiation (BR) is primarily performed via high-energy quanta. The testing parameters are specified by the focal spot size of the high-energy bremsstrahlung radiation. In determining the focal spot size, the high- energy BR portion cannot be experimentally separated from the low-energy BR to use high- energy quanta only. The patterns of BR focal spot formation have been investigated via statistical modeling of the radiation transfer in the target material. The distributions of BR quanta emitted by the target for different energies and emission angles under normal distribution of the accelerated electrons bombarding the target have been obtained, and the ratio of the distribution parameters has been determined.

  15. Opportunities of the energy revolution. Scientific contributions to the KIT

    International Nuclear Information System (INIS)

    Breh, Wolfgang; Schaetzler, Katharina

    2013-01-01

    ''Opportunities for energy revolution'' was the title under which the KIT Energy Center of Karlsruhe Institute of Technology (KIT) in May 2012 held its first annual meeting. The meeting covered the whole Topic of the KIT Energy Center. The present proceedings give those interested the opportunity to delve into the contributions and to provide a differentiated picture of the challenges and opportunities of the energy transition.

  16. PREDICTING RELEVANT EMPTY SPOTS IN SOCIAL INTERACTION

    Institute of Scientific and Technical Information of China (English)

    Yoshiharu MAENO; Yukio OHSAWA

    2008-01-01

    An empty spot refers to an empty hard-to-fill space which can be found in the records of the social interaction, and is the clue to the persons in the underlying social network who do not appear in the records. This contribution addresses a problem to predict relevant empty spots in social interaction. Homogeneous and inhomogeneous networks are studied as a model underlying the social interaction. A heuristic predictor function method is presented as a new method to address the problem. Simulation experiment is demonstrated over a homogeneous network. A test data set in the form of market baskets is generated from the simulated communication. Precision to predict the empty spots is calculated to demonstrate the performance of the presented method.

  17. A construction kit for modeling the security of M-Commerce applications

    OpenAIRE

    Reif, Wolfgang

    2004-01-01

    A construction kit for modeling the security of M-Commerce applications / Dominik Haneberg, Wolfgang Reif, Kurt Stenzel. - In: Applying formal methods : testing, performance and M/E commerce ; FORTE 2004 Workshops The FormEMC ..., Toledo, Spain, October 1 - 2, 2004 ; proceedings / Manuel Núñez ... (ed.). - Berlin u. a : Springer, 2004. - S. 72-85. - (Lecture notes in computer science ; 3236)

  18. Development of MIBI kit for heart imaging

    International Nuclear Information System (INIS)

    Khamis, S.B.; Ab-Wahid, M.

    1998-01-01

    99m Tc-isonitriles have been shown to be a very promising substitute for Thallium-201 ( 201 TI) for myocardial perfusion imaging. In this study, the lyophilized kit of Methoxyisobutylisonitrile (MIBI) was prepared and labeled with 99m Tc. Several factors affecting the labeling yield such as the kit's stannous content, boiling time during labeling, and the volume of 99m Tc used during reconstitution were also investigated. The radiochemical purity (RCP) determination of the labeled product was analyzed by HPLC, solvent-extraction, TLC and ITLC-SG chromatographic methods in various systems. Animal biodistribution study performed in rats indicated the 99m Tc-MIBI accumulation in the myocardial is up to 3 hours with little or no redistribution. Toxicity studies performed indicate no clinical signs of abnormality in mice at injected dose equivalent in amount of 100 times the human dose in proportion to body weight. Stability studies of the labeled complex performed at room temperature showed no change in radiochemical purity (> 95%) 6 hours post-preparation. Compatibility and comparative studies were done using both MINT and commercially available MIBI kits and 99m Tc generator eluates. From the results obtained the MINT produced MIBI kits were found to be comparable in quality to that of commercials. (author)

  19. Performance evaluation of Cepheid Xpert Norovirus kit with a user-modified protocol.

    Science.gov (United States)

    Wong, Rachel Shi-Lei; Yeo, Fion; Chia, Wai Theng; Lee, Chun Kiat; Leong, Mun Han; Ng, Christopher Wai-Siong; Poon, Kok Siong; Yan, Gabriel Zherong; Chiu, Lily-Lily; Yan, Benedict Junrong; Jureen, Roland; Koay, Evelyn Siew-Chuan; Lee, Hong Kai

    2018-03-01

    The Cepheid Xpert® Norovirus kit automates sample processing, nucleic acid extraction, and real-time reverse transcription polymerase chain reactions (RT-PCRs) to detect norovirus genogroups I (GI) and II (GII). Eighty-five stool samples collected between February 2015 and May 2017 were used to compare the performance of a user-modified Xpert assay against a clinically validated laboratory-developed test (LDT). Of the 85 samples, 54 were previously archived in -80°C freezer. The remaining 31 were fresh samples tested concurrently with the LDT. The results of all samples tested using the Xpert kit and LDT were found to be concordant, including 12 GI- and 42 GII-positive samples, 1 GI and GII coinfection, and 30 negative samples. Comparison of the assays showed perfect concordance with a kappa coefficient score of 1.00 (95%CI from 1.00 to 1.00). Of the 30 negative stool samples tested, three samples were positive for rotavirus detected using an immunochromatographic assay, with no cross-reactivity shown in both LDT and Xpert assays. In-run sample processing control of the Xpert assay for all negative samples tested showed no/minor inhibition. Compared to the LDT, the Xpert assay produced similar or better Ct values for detection. It also showed better mitigation of PCR inhibition in stool sample testing. © 2017 Wiley Periodicals, Inc.

  20. Autometallography: tissue metals demonstrated by a silver enhancement kit

    DEFF Research Database (Denmark)

    Danscher, G; Nørgaard, J O; Baatrup, E

    1987-01-01

    , primarily intended for the amplification of colloidal gold particles, has been used to demonstrate these catalytic tissue metals. Sections from animals exposed intravitally to aurothiomalatate, silver lactate, mercury chloride, sodium selenite or perfused with sodium sulphide were subjected to a commercial......In biological tissue, minute accumulations of gold, silver, mercury and zinc can be visualized by a technique whereby metallic silver is precipitated on tiny accumulations of the two noble metals, or on selenites or sulphides of all four metals. In the present study a silver enhancement kit...... silver enhancement kit (IntenSE, Janssen Pharmaceutica). It was found that the kit performs adequately to the silver lactate gum arabic developer and to the photographic emulsion technique. The kit can be used as a silver enhancement medium for the demonstration of zinc by the Neo-Timm and selenium...

  1. Gene Duplication of the zebrafish kit ligand and partitioning of melanocyte development functions to kit ligand a.

    Directory of Open Access Journals (Sweden)

    Keith A Hultman

    2007-01-01

    Full Text Available The retention of particular genes after the whole genome duplication in zebrafish has given insights into how genes may evolve through partitioning of ancestral functions. We examine the partitioning of expression patterns and functions of two zebrafish kit ligands, kit ligand a (kitla and kit ligand b (kitlb, and discuss their possible coevolution with the duplicated zebrafish kit receptors (kita and kitb. In situ hybridizations show that kitla mRNA is expressed in the trunk adjacent to the notochord in the middle of each somite during stages of melanocyte migration and later expressed in the skin, when the receptor is required for melanocyte survival. kitla is also expressed in other regions complementary to kita receptor expression, including the pineal gland, tail bud, and ear. In contrast, kitlb mRNA is expressed in brain ventricles, ear, and cardinal vein plexus, in regions generally not complementary to either zebrafish kit receptor ortholog. However, like kitla, kitlb is expressed in the skin during stages consistent with melanocyte survival. Thus, it appears that kita and kitla have maintained congruent expression patterns, while kitb and kitlb have evolved divergent expression patterns. We demonstrate the interaction of kita and kitla by morpholino knockdown analysis. kitla morphants, but not kitlb morphants, phenocopy the null allele of kita, with defects for both melanocyte migration and survival. Furthermore, kitla morpholino, but not kitlb morpholino, interacts genetically with a sensitized allele of kita, confirming that kitla is the functional ligand to kita. Last, we examine kitla overexpression in embryos, which results in hyperpigmentation caused by an increase in the number and size of melanocytes. This hyperpigmentation is dependent on kita function. We conclude that following genome duplication, kita and kitla have maintained their receptor-ligand relationship, coevolved complementary expression patterns, and that

  2. Comparative sensitivity and inhibitor tolerance of GlobalFiler® PCR Amplification and Investigator® 24plex QS kits for challenging samples.

    Science.gov (United States)

    Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree

    2018-02-17

    In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Assessment of White Spot Lesions and In-Vivo Evaluation of the Effect of CPP-ACP on White Spot Lesions in Permanent Molars of Children.

    Science.gov (United States)

    Munjal, Deepti; Garg, Shalini; Dhindsa, Abhishek; Sidhu, Gagandeep Kaur; Sethi, Harsimran Singh

    2016-05-01

    As hindrance of remineralisation process occurs during orthodontic therapy resulting in decalcification of enamel because number of plaque retention sites increases due to banding and bonding of appliances to teeth. The present analytic study was undertaken to assess the occurrence of white spot lesions in permanent molars of children with and without orthodontic therapy and to evaluate the effect of Casein PhosphoPeptide-Amorphous Calcium Phosphate (CPP-ACP) on white spot lesions in post-orthodontic patients in a given period of time. The study comprised of examination of 679 first permanent molars which were examined to assess the occurrence of smooth surface white spot lesions in children of 8 to 16 years age group. Group I comprised subjects without any orthodontic treatment and Group II comprised of subjects who had undergone orthodontic therapy. The sample size was calculated using the epi-info6 computer package. Treatment group included 20 post-orthodontic patients examined with at least one white spot lesion within the enamel who received remineralizing cream (GC Tooth Mousse, Recaldent, GC Corporation.) i.e., CPP-ACP cream two times a day for 12 consecutive weeks. Computerized image analysis method was taken to evaluate white spot lesions. These frequency and percentages were compared with chi-square test. For comparison of numeric data, paired t-test was used. Of the total 278 (49.6%) first permanent molars showed occurrence of smooth surface white spot lesions out of 560 in Group I and 107 (89.9%) first permanent molars showed presence of white spot lesions out of 119 debanded first permanent molars of children examined in Group II. CPP-ACP therapy group showed reduction in severity of codes which was found to be highly significant after 12 weeks and eight weeks on gingival-third, p-value (spot lesions on teeth undergoing fixed orthodontic therapy according to the present study.

  4. Production of 14C-labeled gas in BACTEC Neisseria Differentiation kits by Neisseria cinerea

    International Nuclear Information System (INIS)

    Boyce, J.M.; Mitchell, E.B. Jr.; Knapp, J.S.; Buttke, T.M.

    1985-01-01

    Six strains of Neisseria cinerea were tested in BACTEC Neisseria Differentiation kits (Johnston Laboratories, Inc., Towson, Md.), and all yielded positive glucose growth indices and negative maltose and fructose growth indices. These results were similar to those achieved with Neisseria gonorrhoeae. However, most of the N. cinerea isolates tested yielded 3-h glucose growth indices that were lower than those obtained with gonococci. 14 C-labeled gas was produced significantly faster by N. gonorrhoeae than by N. cinerea. Additional studies suggested that the 14 C-labeled gas produced by N. cinerea was carbon dioxide. N. cinerea strains were similar to Branhamella catarrhalis strains because both species failed to produce detectable acid from glucose, maltose, sucrose, fructose, and lactose in cysteine-tryptic agar media. However, in contrast to N. cinerea strains, B. catarrhalis strains did not metabolize glucose in BACTEC Neisseria Differentiation kits

  5. FitMindKit: Randomised controlled trial of an automatically tailored online program for mood, anxiety, substance use and suicidality

    Directory of Open Access Journals (Sweden)

    Philip J. Batterham

    2018-06-01

    Full Text Available Purpose: Online mental health programs can be effective in reducing symptoms of depression, anxiety disorders, substance use and suicidal ideation. However, most existing e-mental health programs focus on a single domain of mental health, neglecting comorbidity. Furthermore, few programs are tailored to the symptom patterns of the individual user. FitMindKit was designed to overcome the gaps of existing e-mental health programs, providing tailored, transdiagnostic therapeutic content to address a range of comorbid mental health symptoms. A trial was conducted to test the program's efficacy. Methods: Australian adults with elevated symptoms of depression, anxiety, suicidal ideation and/or substance use were recruited through social media, with n=194 randomised into a fully-automated trial of a 10-day brief intervention. Participants were randomly allocated to receive FitMindKit tailored to their symptoms, an untailored generic version of FitMindKit, or an attention control. Results: Mixed model repeated measures ANOVA indicated that participants in both FitMindKit and the attention control had significant reductions in symptom composite scores. Effects were not significantly greater in the FitMindKit program relative to control, either at post-test or 3-month follow-up. No effects were detected for specific decreases in depression, generalized anxiety, social anxiety, panic, suicidal ideation or alcohol/substance use. There were no significant differences between the tailored and static versions in effectiveness or adherence. Participants in the tailored and static conditions were more satisfied than in the control condition, with some evidence favouring the tailored condition. High attrition reduced power to find effects. Conclusions: FitMindKit provides a model for addressing comorbid mental health symptoms in an online program, using automated tailoring to symptom patterns. Modifications to the program are recommended, along with the need for

  6. Fundamental and clinical evaluation of osteocalcin RIA kit

    Energy Technology Data Exchange (ETDEWEB)

    Kousaka, Tadako; Yamamoto, Itsuo; Kitamura, Nobuyasu; Aoki, Jun; Uneno, Susumu; Sone, Teruki; Kasai, Ryuuichi; Torizuka, Kanji

    1987-06-01

    The laboratory performance of a double antibody radioimmunoassay (RIA) kit for measuring osteocalcin (OC) was tested for incubation, the effect of anticoagulants, serum storage, dilution, recovery, and reproducibility. Serum OC concentrations increased rapidly with the addition of 5 mM or more ethylenediamine tetraacetic acid, although they were not affected by the addition of heparin. Serum OC measurements, obtained at 2 or 3 weeks after sampling, tended to be lower. The other items, except for dilution, were reliable. Using the OC RIA kit, serum OC concentrations were measured in 161 patients with various diseases and 408 volunteers. Normal upper limit for OC was defined as 11.48 ng/ml. Serum OC concentrations were extremely high up to the age of puberty, and thereafter decreased rapidly with the constant values after the age of 20. Women had increased OC values after the latter half of their fourties. Primary hyperparathyroidism, bone metastases of malignancy, and malignant hypercalcemia were occasionally associated with increased OC values, in contrast to hypoparathyroidism showing decreased OC values. Extremely high values of OC were seen in many of the dialysis patients. (Namekawa, K.).

  7. Application of an FSH-RIA-kit in the clinical practice

    International Nuclear Information System (INIS)

    Delzer, W.; Herzmann, H.

    1982-01-01

    First clinical experiences with an FSH-RIA-kit developed in the Central Institute for Isotope- and Radiation Research are reported. Simultaneously carried out LH and FSH determination during the menstruation cycle with special regard of the middle of the cycle revealed increased hormone values in the preovulatory phase. The problem of evaluation of hormone values achieved by different kits (standards), was investigated simultaneous determination of the sera using the own and an imported kit. (author)

  8. Signaling by Kit protein-tyrosine kinase--the stem cell factor receptor.

    Science.gov (United States)

    Roskoski, Robert

    2005-11-11

    Signaling by stem cell factor and Kit, its receptor, plays important roles in gametogenesis, hematopoiesis, mast cell development and function, and melanogenesis. Moreover, human and mouse embryonic stem cells express Kit transcripts. Stem cell factor exists as both a soluble and a membrane-bound glycoprotein while Kit is a receptor protein-tyrosine kinase. The complete absence of stem cell factor or Kit is lethal. Deficiencies of either produce defects in red and white blood cell production, hypopigmentation, and sterility. Gain-of-function mutations of Kit are associated with several human neoplasms including acute myelogenous leukemia, gastrointestinal stromal tumors, and mastocytomas. Kit consists of an extracellular domain, a transmembrane segment, a juxtamembrane segment, and a protein kinase domain that contains an insert of about 80 amino acid residues. Binding of stem cell factor to Kit results in receptor dimerization and activation of protein kinase activity. The activated receptor becomes autophosphorylated at tyrosine residues that serve as docking sites for signal transduction molecules containing SH2 domains. The adaptor protein APS, Src family kinases, and Shp2 tyrosyl phosphatase bind to phosphotyrosine 568. Shp1 tyrosyl phosphatase and the adaptor protein Shc bind to phosphotyrosine 570. C-terminal Src kinase homologous kinase and the adaptor Shc bind to both phosphotyrosines 568 and 570. These residues occur in the juxtamembrane segment of Kit. Three residues in the kinase insert domain are phosphorylated and attract the adaptor protein Grb2 (Tyr703), phosphatidylinositol 3-kinase (Tyr721), and phospholipase Cgamma (Tyr730). Phosphotyrosine 900 in the distal kinase domain binds phosphatidylinositol 3-kinase which in turn binds the adaptor protein Crk. Phosphotyrosine 936, also in the distal kinase domain, binds the adaptor proteins APS, Grb2, and Grb7. Kit has the potential to participate in multiple signal transduction pathways as a result of

  9. Microgripper construction kit

    Science.gov (United States)

    Gengenbach, Ulrich K.; Hofmann, Andreas; Engelhardt, Friedhelm; Scharnowell, Rudolf; Koehler, Bernd

    2001-10-01

    A large number of microgrippers has been developed in industry and academia. Although the importance of hybrid integration techniques and hence the demand for assembly tools grows continuously a large part of these developments has not yet been used in industrial production. The first grippers developed for microassembly were basically vacuum grippers and downscaled tweezers. Due to increasingly complex assembly tasks more and more functionality such as sensing or additional functions such as adhesive dispensing has been integrated into gripper systems over the last years. Most of these gripper systems are incompatible since there exists no standard interface to the assembly machine and no standard for the internal modules and interfaces. Thus these tools are not easily interchangeable between assembly machines and not easily adaptable to assembly tasks. In order to alleviate this situation a construction kit for modular microgrippers is being developed. It is composed of modules with well defined interfaces that can be combined to build task specific grippers. An abstract model of a microgripper is proposed as a tool to structure the development of the construction kit. The modular concept is illustrated with prototypes.

  10. A time-series analysis of the crude oil spot and futures markets

    International Nuclear Information System (INIS)

    Quan Jing.

    1990-01-01

    First, the existence of the relationship is tested. Second, after the relationship is established, it is tested to determine the direction of causality. Most of previous research on this issue ignored the first step, and the existence of the relationship was taken for granted. Unfortunately, however, this assumption is not justified since it does not necessarily hold. The first relationship investigated in this study is between the crude oil spot and futures prices. It is found that spot price leads futures prices instead of the futures price providing information on the spot price. Two additional relationships studied are those between the OPEC oil supply and the futures prices and that between the same supply and spot prices. In the case of OPEC supply and spot prices, a self-adaptive model with supply interruption dummy variables is introduced to study the price behavior. It is found that prices follow an adaptive process, that is, the previous price information offers powerful influence on the current price

  11. Jumping-droplet electronics hot-spot cooling

    Science.gov (United States)

    Oh, Junho; Birbarah, Patrick; Foulkes, Thomas; Yin, Sabrina L.; Rentauskas, Michelle; Neely, Jason; Pilawa-Podgurski, Robert C. N.; Miljkovic, Nenad

    2017-03-01

    Demand for enhanced cooling technologies within various commercial and consumer applications has increased in recent decades due to electronic devices becoming more energy dense. This study demonstrates jumping-droplet based electric-field-enhanced (EFE) condensation as a potential method to achieve active hot spot cooling in electronic devices. To test the viability of EFE condensation, we developed an experimental setup to remove heat via droplet evaporation from single and multiple high power gallium nitride (GaN) transistors acting as local hot spots (4.6 mm × 2.6 mm). An externally powered circuit was developed to direct jumping droplets from a copper oxide (CuO) nanostructured superhydrophobic surface to the transistor hot spots by applying electric fields between the condensing surface and the transistor. Heat transfer measurements were performed in ambient air (22-25 °C air temperature, 20%-45% relative humidity) to determine the effect of gap spacing (2-4 mm), electric field (50-250 V/cm) and applied heat flux (demonstrated to 13 W/cm2). EFE condensation was shown to enhance the heat transfer from the local hot spot by ≈200% compared to cooling without jumping and by 20% compared to non-EFE jumping. Dynamic switching of the electric field for a two-GaN system reveals the potential for active cooling of mobile hot spots. The opportunity for further cooling enhancement by the removal of non-condensable gases promises hot spot heat dissipation rates approaching 120 W/cm2. This work provides a framework for the development of active jumping droplet based vapor chambers and heat pipes capable of spatial and temporal thermal dissipation control.

  12. Jumping-droplet electronics hot-spot cooling

    International Nuclear Information System (INIS)

    Oh, Junho; Birbarah, Patrick; Foulkes, Thomas; Yin, Sabrina L.; Rentauskas, Michelle

    2017-01-01

    Demand for enhanced cooling technologies within various commercial and consumer applications has increased in recent decades due to electronic devices becoming more energy dense. This study demonstrates jumping-droplet based electric-field-enhanced (EFE) condensation as a potential method to achieve active hot spot cooling in electronic devices. To test the viability of EFE condensation, we developed an experimental setup to remove heat via droplet evaporation from single and multiple high power gallium nitride (GaN) transistors acting as local hot spots (4.6 mm x 2.6 mm). An externally powered circuit was developed to direct jumping droplets from a copper oxide (CuO) nanostructured superhydrophobic surface to the transistor hot spots by applying electric fields between the condensing surface and the transistor. Heat transfer measurements were performed in ambient air (22-25°C air temperature, 20-45% relative humidity) to determine the effect of gap spacing (2-4 mm), electric field (50-250 V/cm), and heat flux (demonstrated to 13 W/cm"2). EFE condensation was shown to enhance the heat transfer from the local hot spot by ≈ 200% compared to cooling without jumping and by 20% compared to non-EFE jumping. Dynamic switching of the electric field for a two-GaN system reveals the potential for active cooling of mobile hot spots. The opportunity for further cooling enhancement by the removal of non-condensable gases promises hot spot heat dissipation rates approaching 120 W/cm"2. Finally, this work provides a framework for the development of active jumping droplet based vapor chambers and heat pipes capable of spatial and temporal thermal dissipation control.

  13. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  14. A feature-based approach to modeling protein-protein interaction hot spots.

    Science.gov (United States)

    Cho, Kyu-il; Kim, Dongsup; Lee, Doheon

    2009-05-01

    Identifying features that effectively represent the energetic contribution of an individual interface residue to the interactions between proteins remains problematic. Here, we present several new features and show that they are more effective than conventional features. By combining the proposed features with conventional features, we develop a predictive model for interaction hot spots. Initially, 54 multifaceted features, composed of different levels of information including structure, sequence and molecular interaction information, are quantified. Then, to identify the best subset of features for predicting hot spots, feature selection is performed using a decision tree. Based on the selected features, a predictive model for hot spots is created using support vector machine (SVM) and tested on an independent test set. Our model shows better overall predictive accuracy than previous methods such as the alanine scanning methods Robetta and FOLDEF, and the knowledge-based method KFC. Subsequent analysis yields several findings about hot spots. As expected, hot spots have a larger relative surface area burial and are more hydrophobic than other residues. Unexpectedly, however, residue conservation displays a rather complicated tendency depending on the types of protein complexes, indicating that this feature is not good for identifying hot spots. Of the selected features, the weighted atomic packing density, relative surface area burial and weighted hydrophobicity are the top 3, with the weighted atomic packing density proving to be the most effective feature for predicting hot spots. Notably, we find that hot spots are closely related to pi-related interactions, especially pi . . . pi interactions.

  15. A feature-based approach to modeling protein–protein interaction hot spots

    Science.gov (United States)

    Cho, Kyu-il; Kim, Dongsup; Lee, Doheon

    2009-01-01

    Identifying features that effectively represent the energetic contribution of an individual interface residue to the interactions between proteins remains problematic. Here, we present several new features and show that they are more effective than conventional features. By combining the proposed features with conventional features, we develop a predictive model for interaction hot spots. Initially, 54 multifaceted features, composed of different levels of information including structure, sequence and molecular interaction information, are quantified. Then, to identify the best subset of features for predicting hot spots, feature selection is performed using a decision tree. Based on the selected features, a predictive model for hot spots is created using support vector machine (SVM) and tested on an independent test set. Our model shows better overall predictive accuracy than previous methods such as the alanine scanning methods Robetta and FOLDEF, and the knowledge-based method KFC. Subsequent analysis yields several findings about hot spots. As expected, hot spots have a larger relative surface area burial and are more hydrophobic than other residues. Unexpectedly, however, residue conservation displays a rather complicated tendency depending on the types of protein complexes, indicating that this feature is not good for identifying hot spots. Of the selected features, the weighted atomic packing density, relative surface area burial and weighted hydrophobicity are the top 3, with the weighted atomic packing density proving to be the most effective feature for predicting hot spots. Notably, we find that hot spots are closely related to π–related interactions, especially π · · · π interactions. PMID:19273533

  16. Particle-wave discrimination in Poisson spot experiments

    International Nuclear Information System (INIS)

    Reisinger, T; Bracco, G; Holst, B

    2011-01-01

    Matter-wave interferometry has been used extensively over the last few years to demonstrate the quantum-mechanical wave nature of increasingly larger and more massive particles. We have recently suggested the use of the historical Poisson spot setup to test the diffraction properties of larger objects. In this paper, we present the results of a classical particle van der Waals (vdW) force model for a Poisson spot experimental setup and compare these to Fresnel diffraction calculations with a vdW phase term. We include the effect of disc-edge roughness in both models. Calculations are performed with D 2 and with C 70 using realistic parameters. We find that the sensitivity of the on-axis interference/focus spot to disc-edge roughness is very different in the two cases. We conclude that by measuring the intensity on the optical axis as a function of disc-edge roughness, it can be determined whether the objects behave as de Broglie waves or classical particles. The scaling of the Poisson spot experiment to larger molecular masses is, however, not as favorable as in the case of near-field light-grating-based interferometers. Instead, we discuss the possibility of studying the Casimir-Polder potential using the Poisson spot setup.

  17. A silent allele in the locus D5S818 contained within the PowerPlex®21 PCR Amplification Kit.

    Science.gov (United States)

    Chen, Ling; Tai, Yunchun; Qiu, Pingming; Du, Weian; Liu, Chao

    2015-11-01

    Three paternity tests cases were found with a single locus mismatch at the locus D5S818 with PowerPlex®21 PCR Amplification Kit (Promega). Forward and reverse primers were redesigned to type the samples again and to evaluate if there were alleles dropped out. The results showed the existence of a silent allele 12 in all the three families, due to a point mutation that changed cytosine to adenine at 90 nucleotides upstream from the 5' end of the AGAT repeat sequences in all the six individuals. A single locus mismatch due to a silent allele may occur in any locus using any kit. Therefore, we recommend using multiple kits to confirm the results in paternity testing cases with mismatches, especially when there is a single locus mismatch with homozygote involved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. An interface board for developing control loops in power electronics based on microcontrollers and DSPs Cores -Arduino /ChipKit /dsPIC /DSP /TI Piccolo

    DEFF Research Database (Denmark)

    Pittini, Riccardo; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    and development environment. Moreover, the interface board can operate with open hardware Arduino-like boards such as the ChipKit Uno32. The paper also describes how to enhance the performance of a ChipKit Uno32 with a dsPIC obtaining a more suitable solution for power electronics. The basic blocks and interfaces...... of the boards are presented in detail as well as the board main specifications. The board operation has been tested with three core platforms: TI Piccolo controlSTICK, a Microchip dsPIC and a ChipKit Uno32 (Arduino-like platform). The board was used for generating test signals for characterizing 1200 V Si...

  19. Kits para aerossol em um serviço de saúde: uma análise microbiológica após reprocessamento Kits para aerosol en un servicio de salud: un análisis microbiológico post procesamiento Aerosol kits in a health service: a post-processing microbiologic analysis

    Directory of Open Access Journals (Sweden)

    Patrícia Staciarini Anders

    2008-06-01

    . Se aisló un total de 101 UFC, 39 provenientes de los vasos, 20 de las extensiones y 42 de las máscaras. Entre los patógenos aislados se destacan: Staphylococcus coagulase positivo, Staphylococcus coagulase negativo, Bastones Gram negativo fermentadores, Bastones Gram negativo no fermentadores, micrococosy levaduras. La detección microbiológica indica probables fallas en el reprocesamiento de esos artículos.Aerosol kits are used in treatments of respiratory illnesses and require at least an intermediate level of disinfection for their reuse. The objectives of the study were to verify possible contamination of kits after they were processed as well as to identify the microorganisms that were isolated in them. This transversal experimental study was conducted in the pediatric unit of a hospital in Goiânia, State of Goiás. Samples were collected from three different parts (masks, cups and hoses of 15 previously disinfected kits and placed in different culture media, and the microorganisms that were isolated were identified through biochemical tests. Of the kits that were analyzed, 13 cups, 9 hoses and 13 masks were found to be contaminated. A total of 101 CFU were isolated 39 from the cups, 20 from the hoses, and 42 the masks. Among the pathogens found were coagulase-positive Staphylococci, coagulase-negative Staphylococci, Gram negative fermenter rods, Gram negative nonfermenter rods, micrococcus and yeast. Microbial presence indicates probable inefficiencies in processing these items.

  20. Tyrosine Kinase Inhibition in HPV-related Squamous Cell Carcinoma Reveals Beneficial Expression of cKIT and Src.

    Science.gov (United States)

    Kramer, Benedikt; Kneissle, Marcel; Birk, Richard; Rotter, Nicole; Aderhold, Christoph

    2018-05-01

    Therapeutic options of locally advanced or metastatic head and neck squamous cell carcinoma (HNSCC) are limited. Src and cKIT are key protein regulators for local tumor progression. The aim of the study was to investigate the therapeutic potential of targeted therapies in human squamous cell carcinoma (HNSCC) in vitro. Therefore, the influence of the selective tyrosine kinase inhibitors niotinib, dasatinib, erlotinib, gefitinib and afatinib on Src and cKIT expression in Human papilloma virus (HPV)-positive and HPV-negative squamous cancer cells (SCC) was analyzed in vitro. ELISA was performed to evaluate the expression of Src and cKIT under the influence of nilotinib, dasatinib, erlotinib, gefitinib and afatinib (10 μmol/l) in HPV-negative and HPV-positive SCC (24-96 h of incubation). Gefitinib significantly increased cKIT expression in HPV-positive and HPV-negative cells whereas nilotinib and afatinib decreased cKIT expression in HPV-positive SCC. The influence of tyrosine kinase inhibitors in HPV-negative SCC was marginal. Surprisingly, Src expression was significantly increased by all tested tyrosine kinase inhibitors in HPV-positive SCC. The results revealed beneficial and unexpected information concerning the interaction of selective tyrosine kinase inhibitors and the tumor biology of HNSCC. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  1. Tumor markers kits development for use in radioimmunometric assays

    International Nuclear Information System (INIS)

    Ahmed, B.

    1997-01-01

    The immunoassays such as RIA and IRMA are now widely used through the world for the quantitation of a variety of substances in the biological fluid for their high sensibility and specificity which required simple equipments. These techniques are also very used in Algeria for an effective amelioration of public heath The assays kits of RIA/IRMA of thyroid hormones are the most used, followed by peptidic hormones, steroids hormones and IRMA Tumor Markers (T.M) kits. In spite of the important demand, of tumor markers kits for the diagnosis and follow up of cancers their use are always insufficient due to the high cost. The research contract programme proposed by IAEA on the theme 'The Developments of IRMA Tumor Markers Kits' of prostate specific Antigen (PSA) and Tissue Polypeptide Specific Antigen (TPS) will allowed us to produce locally with best quality-price, the main reagents for PSA and TPS IRMA assays kits for diagnosis and follow up the prostate and breast cancers which are very spready in the country. This report include the following points: Generalities on the use of tumor markers in Algeria, programme for the Development of the PSA IRMA assay (schedule of protocols applied for each reagents; annual planning for assessing the programme activities) and conclusion

  2. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  3. Development and validation of the AmpFℓSTR® Identifiler® Direct PCR Amplification Kit: a multiplex assay for the direct amplification of single-source samples.

    Science.gov (United States)

    Wang, Dennis Y; Chang, Chien-Wei; Lagacé, Robert E; Oldroyd, Nicola J; Hennessy, Lori K

    2011-07-01

    The AmpFℓSTR(®) Identifiler(®) Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single-source blood and buccal samples on FTA(®) card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay's sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA(®) cards, and the assay's specificity was verified by establishing minimal cross-reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA(®) substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler(®) Direct Kit for forensic standards and database samples genotyping. © 2011 American Academy of Forensic Sciences.

  4. SPOTTED STAR LIGHT CURVES WITH ENHANCED PRECISION

    International Nuclear Information System (INIS)

    Wilson, R. E.

    2012-01-01

    The nearly continuous timewise coverage of recent photometric surveys is free of the large gaps that compromise attempts to follow starspot growth and decay as well as motions, thereby giving incentive to improve computational precision for modeled spots. Due to the wide variety of star systems in the surveys, such improvement should apply to light/velocity curve models that accurately include all the main phenomena of close binaries and rotating single stars. The vector fractional area (VFA) algorithm that is introduced here represents surface elements by small sets of position vectors so as to allow accurate computation of circle-triangle overlap by spherical geometry. When computed by VFA, spots introduce essentially no noticeable scatter in light curves at the level of one part in 10,000. VFA has been put into the Wilson-Devinney light/velocity curve program and all logic and mathematics are given so as to facilitate entry into other such programs. Advantages of precise spot computation include improved statistics of spot motions and aging, reduced computation time (intrinsic precision relaxes needs for grid fineness), noise-free illustration of spot effects in figures, and help in guarding against false positives in exoplanet searches, where spots could approximately mimic transiting planets in unusual circumstances. A simple spot growth and decay template quantifies time profiles, and specifics of its utilization in differential corrections solutions are given. Computational strategies are discussed, the overall process is tested in simulations via solutions of synthetic light curve data, and essential simulation results are described. An efficient time smearing facility by Gaussian quadrature can deal with Kepler mission data that are in 30 minute time bins.

  5. 21-cm lensing and the cold spot in the cosmic microwave background.

    Science.gov (United States)

    Kovetz, Ely D; Kamionkowski, Marc

    2013-04-26

    An extremely large void and a cosmic texture are two possible explanations for the cold spot seen in the cosmic microwave background. We investigate how well these two hypotheses can be tested with weak lensing of 21-cm fluctuations from the epoch of reionization measured with the Square Kilometer Array. While the void explanation for the cold spot can be tested with Square Kilometer Array, given enough observation time, the texture scenario requires significantly prolonged observations, at the highest frequencies that correspond to the epoch of reionization, over the field of view containing the cold spot.

  6. Oncogenic activation of v-kit involves deletion of a putative tyrosine-substrate interaction site.

    Science.gov (United States)

    Herbst, R; Munemitsu, S; Ullrich, A

    1995-01-19

    The transforming gene of the Hardy-Zuckerman-4 strain of feline sarcoma virus, v-kit, arose by transduction of the cellular c-kit gene, which encodes the receptor tyrosine kinase (RTK) p145c-kit. To gain insight into the molecular basis of the v-kit transforming potential, we characterized the feline c-kit by cDNA cloning. Comparison of the feline v-kit and c-kit sequences revealed, in addition to deletions of the extracellular and transmembrane domains, three additional mutations in the v-kit oncogene product: deletion of tyrosine-569 and valine-570, the exchange of aspartate at position 761 to glycine, and replacement of the C-terminal 50 amino acids by five unrelated residues. Examinations of individual v-kit mutations in the context of chimeric receptors yielded inhibitory effects for some mutants on both autophosphorylation and substrate phosphorylation functions. In contrast, deletion of tyrosine-569 and valine-570 significantly enhanced transforming and mitogenic activities of p145c-kit, while the other mutations had no significant effects. Conservation in subclass III RTKs and the identification of the corresponding residue in beta PDGF-R, Y579, as a binding site for src family tyrosine kinases suggests an important role for Y568 in kit signal regulation and the definition of its oncogenic potential. Repositioning of Y571 by an inframe two codon deletion may be the crucial alteration resulting in enhancement of v-kit oncogenic activity.

  7. C-MORE Science Kits: Putting Technology in the Hands of K-12 Teachers and Students

    Science.gov (United States)

    Achilles, K.; Weersing, K.; Daniels, C.; Puniwai, N.; Matsuzaki, J.; Bruno, B. C.

    2008-12-01

    The Center for Microbial Oceanography: Research and Education (C-MORE) is a NSF Science and Technology Center based at the University of Hawaii. The C-MORE education and outreach program offers a variety of resources and professional development opportunities for science educators, including online resources, participation in oceanography research cruises, teacher-training workshops, mini-grants to incorporate microbial oceanography-related content and activities into their classroom and, most recently, C- MORE science kits. C-MORE science kits provide hands-on classroom, field, and laboratory activities related to microbial oceanography for K-12 students. Each kit comes with complete materials and instructions, and is available free of charge to Hawaii's public school teachers. Several kits are available nationwide. C-MORE science kits cover a range of topics and technologies and are targeted at various grade levels. Here is a sampling of some available kits: 1) Marine Murder Mystery: The Case of the Missing Zooxanthellae. Students learn about the effect of climate change and other environmental threats on coral reef destruction through a murder-mystery experience. Participants also learn how to use DNA to identify a suspect. Grades levels: 3-8. 2) Statistical sampling. Students learn basic statistics through an exercise in random sampling, with applications to microbial oceanography. The laptops provided with this kit enable students to enter, analyze, and graph their data using EXCEL. Grades levels: 6-12. 3) Chlorophyll Lab. A research-quality fluorometer is used to measure the chlorophyll content in marine and freshwater systems. This enables students to compare biomass concentrations in samples collected from various locations. Grades levels: 9-12. 4) Conductivity-Temperature-Depth (CTD). Students predict how certain variables (e.g., temperature, pressure, chlorophyll, oxygen) vary with depth. A CTD, attached to a laptop computer, is deployed into deep water

  8. Evaluation of two commercial, rapid, ELISA kits testing or scrapie in retro-pharyngeal lymph nodes in sheep

    NARCIS (Netherlands)

    Kittelberger, R.; McIntuyre, L.; Watts, S.; MacDiarmid, S.; Hannah, M.J.; Jenner, J.; Bueno, R.; Swainsbury, R.; Langeveld, J.P.M.; Keulen, van L.J.M.; Zijderveld, van F.G.; Wemheuer, W.M.; Richt, J.A.; Sorenson, S.J.; Pigott, C.J.; O'Keefe, J.S.

    2014-01-01

    AIMS: To estimate the number of cases of scrapie that would occur in sheep of different prion protein (PrP) genotypes if scrapie was to become established in New Zealand, and to compare the performance of two commercially available, rapid ELISA kits using ovine retro-pharyngeal lymph nodes (RLN)

  9. Validity of a commercial kit for detection of antibodies in bovine serum in an endemic area for fasciolosis

    Directory of Open Access Journals (Sweden)

    Aline Nunes Simões

    Full Text Available Abstract Fasciolosis is caused by Fasciola hepatica that affects the bile ducts and liver parenchyma of ruminants, which can result in economic loss. This study aimed to carry out the validity of the commercial kit ELISA® indirect front of the simple fecal sedimentation test used as the standard. 143 samples were collected blood and feces of cattle from Jerome, south of the Espírito Santo. Serum samples were left at -80 °C and used to perform the ELISA kit IDEXX®. All animals to stool examinations were also positive to the ELISA (22 and negative samples to test stool (121, 52 animals reacted positively against the antibody research. The frequency of fasciolosis was 15.4% in the stool examinations and 51.8% by ELISA. The validity was calculated by sensitivity (100%, specificity (57%, positive predictive value (29% and negative predictive value (100%, and the correlation between the tests calculated using the kappa index of 0.35. The better sensitivity of the ELISA commercial kit should not be a separately evaluated, since the cost benefit and the technical facility must be considered.

  10. Evaluation of rapid immuno chromatographic assay kit using monoclonal mpt64 antibodies for identification of mycobacterium tuberculosis complex

    International Nuclear Information System (INIS)

    Satti, L.; Ikram, A.; Malik, N.

    2010-01-01

    To evaluate the performance of rapid immuno chromatographic kit MPT64 Ag for the identification of Mycobacterium tuberculosis complex from various Mycobacterium tuberculosis culture positive specimens. Department of Microbiology, Armed Forces Institute of Pathology Rawalpindi, from August 2008 through March 2009. Eighty four Mycobacterium tuberculosis positive cultures on I BACTEC 460 and MGIT 960, one ATCC 25177 MTB strain, three institutional control MTB strains, two institutional control MOTT strains and 20 different bacterial isolates were tested. Tests were performed according to the instructional manual. Out of total 84 tested samples, MPT64 showed positive result in 80 cultures. Only four positive cultures did not display any band on MPT64 kit. These four strains were reconfirmed as Mycobacterium tuberculosis by PCR method. MOTT control strains and all the 20 bacterial isolates were negative for band. The sensitivity and specificity of ICT assay in our study was 95.2% and 100% respectively. Rapid MPT64 Kit is a good diagnostic tool to differentiate between Mycobacterium tuberculosis complex and MOTT with 100% specificity. The technique is simple and can provide prompt information to the clinicians to initiate early and appropriate antituberculosis therapy. (author)

  11. RestKit for iOS standard guide

    CERN Document Server

    Kalapun, Taras

    2013-01-01

    A step-by-step, example-based guide to learning how you can link your apps and web services using RestKit.This book is for iOS developers of all levels who are interested in boosting their productivity by utilizing third party libraries and who have a willingness to learn how to build RESTful apps using the RestKit framework. A basic knowledge of Objective-C is required as well as a simple understanding of how to use CoreData.

  12. Technetium-99m ceftizoxime kit preparation

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento

    2005-01-01

    The aim of this work was to prepare a kit of 99 m Tc-ceftizoxime ( 99m Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99m Tc pertechnetate solution (Na 99m Tc O 4- ) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99m Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99m Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99 m Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99m Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ( 99m Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes. (author)

  13. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    Directory of Open Access Journals (Sweden)

    Maity Susmita

    2012-11-01

    Full Text Available Abstract Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.; ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd. gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd., Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd. did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100% except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.. The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p  Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for

  14. Late development of homoeothermy in mink (Mustela vison) kits - a strategy for maximum survival rate

    DEFF Research Database (Denmark)

    Tauson, A-H; Chwalibog, André; Tygesen, M P

    2006-01-01

    and after the experiments and evaporative water losses (EWL) were calculated. When exposed to L temperature, single kits responded with a very low HE until 29 days of age, and groups of kits until 14 days of age. It was not until they reached an age of approximately 6 weeks that single kits showed a clear...... thermoregulatory response to the L temperature by increased HE, whereas groups of kits showed increased HE from 29th day onwards. When kept at H temperature, HE was low initially, but all kits showed elevated HE at 8 days of age, and the metabolic rate was similar for single kits and kits huddling in groups....... Evaporative water losses was higher among single than among groups of kits and slightly lower but more variable for animals at L than at H temperature. It was concluded that mink kits develop functional homoeothermy at an age of close to 6 weeks and that the failure of very young kits to thermoregulate...

  15. Rocky Mountain spotted fever

    Science.gov (United States)

    ... spotted fever on the foot Rocky Mountain spotted fever, petechial rash Antibodies Deer and dog tick References McElligott SC, Kihiczak GG, Schwartz RA. Rocky Mountain spotted fever and other rickettsial infections. In: Lebwohl MG, Heymann ...

  16. Solid state nuclear track detectors kit for the use in teaching

    International Nuclear Information System (INIS)

    Khouri, M.T.F.C.; Koskinas, M.F.

    1988-11-01

    The kit intends to improve the possibilities in performing experiments of Nuclear Physics in Modern Physics laboratories of Physics Course introducing the solid state nuclear track detectors. In these materials the passage of heavily ionizing nuclear particles creates paths (tracks) that may be revealed and made visible in an optical microscope. By the help of the kit several experiments and/or demonstrations may be performed. The kit contains solid state nuclear track detectors unirradiated and irradiated, irradiated etched and unetched sheets: an alpha source of 241 Am and an instrution text with photomicrographs. To use the kit the laboratory must have an ordinary optical microscope. (author) [pt

  17. Kit development for labelling erythrocytes or leukocytes with technetium-99m in vitro

    International Nuclear Information System (INIS)

    Wang Xuebin; Han Quansheng; Wang Jingcheng; Mi Hongzhi

    1996-01-01

    This study developed a modified pre tinning method for labeling erythrocytes with technetium-99m in vitro using a kit which contains stannous chloride stabilized with geneticist acid (GA) in lyophilized form. This GA-kit a sterile closed system that does not require centrifugation,washing and separation of the RBCs. The kit is simple to use and labeling takes ∼ 30 min with a typical labeling efficiency of 97.3% ± 1.2% for 60 determinations. Imaging studies were performed in rabbit using GA-kit in vitro labeling procedure and PYP-kit in vivo labeling. It shows that the heart-to-background ratio with GA in vitro labeling were significantly higher than with in vivo labeling. Leukocytes labeling with technetium-99m using the same GA kit also was studied. The labeling efficiency was 20 ∼ 41%. Thus, the GA kit is versatile and cost-effective. (author). 21 refs., 5 figs., 2 tabs

  18. Investor preferences for oil spot and futures based on mean-variance and stochastic dominance

    NARCIS (Netherlands)

    H.H. Lean (Hooi Hooi); M.J. McAleer (Michael); W.-K. Wong (Wing-Keung)

    2010-01-01

    textabstractThis paper examines investor preferences for oil spot and futures based on mean-variance (MV) and stochastic dominance (SD). The mean-variance criterion cannot distinct the preferences of spot and market whereas SD tests leads to the conclusion that spot dominates futures in the downside

  19. Liquid kit for preparation of {sup 188}rhenium-etidronate

    Energy Technology Data Exchange (ETDEWEB)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), SP (Brazil). Centro de Radiofarmacia]. E-mail: baszot@gmail.com

    2005-10-15

    The aim of this study was the preparation of a liquid kit for radiolabeling of {sup 188} Re-HEDP (hydroxyethylidene diphosphonate). {sup 188} Re was obtained from alumina based {sup 188} W/{sup 188} Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of {sup 188} Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  20. Accuracy of a self-collection kit for the microbiological study of the vaginal content

    Directory of Open Access Journals (Sweden)

    Mauro Romero L. Passos

    Full Text Available Diagnosis of vaginal discharge is frequently performed in an empirical way, leading to inadequate treatment. This study tested the accuracy of a self-collection kit for microbiological study of the vaginal content. One hundred and forty-two women of Family Health Program units in Niterói and Piraí cities were enrolled in order to have their vaginal content studied. A brief explanation and a self-collection kit were provided in order to sample the vaginal content. The self-collection kit was composed of one empty plastic tube, two glass slides, a long handle cytobrush, an identification card and guideline notes. The vaginal sample was applied on the glass slides by the women and stained by Gram technique. A second sampling was done by the medical personnel. The microbiological diagnosis in a blinded analysis was made under optical microscopy. A validation diagnosis test was done taking the medical collection results as a gold standard. A total of 106 women had followed the protocol and were included in the study. Microbiological analysis was unsatisfactory in 12 cases (6 cases of self-collection material and 6 cases of medical collection. The microbiological analyses in the self-collection and in the medical collection material were respectively: bacterial vaginosis in 21.7% and 17.9%, non bacillar flora in 10.3% and 11.3%, vaginal trichomoniasis in 5.66% and 5.6%, candidiasis in 3.78% and 2.8% and a normal microbiota in 52.8% and 56.6%. The Kappa coefficient suggested a "very good correlation" of the microbiological results between the two methods of collection (K=0.7945. The self-collection kit provides samples for microbiological analysis of the vaginal microbiota as good as medical collection.

  1. 33 CFR 149.323 - What are the requirements for first aid kits?

    Science.gov (United States)

    2010-07-01

    ... first aid kits? 149.323 Section 149.323 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Lifesaving Equipment Manned Deepwater Port Requirements § 149.323 What are the requirements for first aid kits? (a) Each manned deepwater port must have an industrial first aid kit, approved by an appropriate...

  2. Adjusting dental ceramics: An in vitro evaluation of the ability of various ceramic polishing kits to mimic glazed dental ceramic surface.

    Science.gov (United States)

    Steiner, René; Beier, Ulrike S; Heiss-Kisielewsky, Irene; Engelmeier, Robert; Dumfahrt, Herbert; Dhima, Matilda

    2015-06-01

    During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. The ceramic systems and polishing kits statistically affected surface roughness (Pceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (Pceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. The Spotting Distribution of Wildfires

    Directory of Open Access Journals (Sweden)

    Jonathan Martin

    2016-06-01

    Full Text Available In wildfire science, spotting refers to non-local creation of new fires, due to downwind ignition of brands launched from a primary fire. Spotting is often mentioned as being one of the most difficult problems for wildfire management, because of its unpredictable nature. Since spotting is a stochastic process, it makes sense to talk about a probability distribution for spotting, which we call the spotting distribution. Given a location ahead of the fire front, we would like to know how likely is it to observe a spot fire at that location in the next few minutes. The aim of this paper is to introduce a detailed procedure to find the spotting distribution. Most prior modelling has focused on the maximum spotting distance, or on physical subprocesses. We will use mathematical modelling, which is based on detailed physical processes, to derive a spotting distribution. We discuss the use and measurement of this spotting distribution in fire spread, fire management and fire breaching. The appendix of this paper contains a comprehensive review of the relevant underlying physical sub-processes of fire plumes, launching fire brands, wind transport, falling and terminal velocity, combustion during transport, and ignition upon landing.

  4. Clinical effectiveness and cost-effectiveness of use of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [LISA-TRACKER® enzyme-linked immunosorbent assay (ELISA) kits, TNF-α-Blocker ELISA kits and Promonitor® ELISA kits] versus standard care in patients with Crohn's disease: systematic reviews and economic modelling.

    Science.gov (United States)

    Freeman, Karoline; Connock, Martin; Auguste, Peter; Taylor-Phillips, Sian; Mistry, Hema; Shyangdan, Deepson; Court, Rachel; Arasaradnam, Ramesh; Sutcliffe, Paul; Clarke, Aileen

    2016-11-01

    Systematic reviews and economic modelling of clinical effectiveness and cost-effectiveness of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [using LISA-TRACKER ® enzyme-linked immunosorbent assay (ELISA) kits (Theradiag, Marne La Vallee, France, or Alpha Laboratories, Heriot, UK), TNF-α-Blocker ELISA kits (Immundiagnostik AG, Bensheim, Germany) and Promonitor ® ELISA kits (Proteomika, Progenika Biopharma, Bizkaia, Spain)] versus standard care for Crohn's disease (CD). Multiple electronic databases were searched from inception to December 2014 in order to identify primary studies and meta-analyses. Patients with moderate to severe active CD treated with infliximab (IFX) (Remicade ® , Merck Sharp & Dohme Ltd, Kenilworth, NJ, USA) or adalimumab (ADA) (Humira ® , AbbVie Inc., North Chicago, IL, USA). Monitoring of serum anti-TNF-α (IFX or ADA) and/or of anti-drug antibody levels using test assays with a test-treatment algorithm. Standard care. Any patient-related outcome, test agreement and cost-effectiveness estimates. The quality assessments used recognised checklists (Quality Assessment of Diagnostic Accuracy Studies-2, Cochrane, Philips and Consolidated Health Economic Evaluation Reporting Standards). Evidence was synthesised using narrative review and meta-analysis. A Markov model was built in TreeAge Pro 2013 (TreeAge Software, Inc., Williamstown, MA, USA). The model had a 4-week cycle and a 10-year time horizon, adopted a NHS and Personal Social Services perspective and used a linked evidence approach. Costs were adjusted to 2013/14 prices and discounted at 3.5%. We included 68 out of 2434 and 4 out of 2466 studies for the clinical effectiveness and cost-effectiveness reviews, respectively. Twenty-three studies comparing test methods were identified. Evidence on test concordance was sparse and contradictory, offering scant data for a linked evidence approach. Three studies [two randomised controlled trials (RCTs) and one

  5. Lead lag relationships between futures and spot prices

    Energy Technology Data Exchange (ETDEWEB)

    Asche, Frank; Guttormsen, Atle G

    2002-01-01

    In this paper we examine the relationship between spot and futures prices. This is traditionally done by testing for cointegration with the Engle and Granger methodology, before one specifies an error correction models in order to draw inference about causality. This approach, although appealing for its simplicity, is problematic on at least two accounts. First, the approach is only valid given an exogeneity assumption, which is what one wants to test, and second, given that there are several contracts with different times to expiration, bivariate specifications cannot capture all the relevant information. We show that both problems can be avoided if the tests are carried out in a multivariate framework like the Johansen test. An empirical application is carried out on futures prices for gas oil. Findings indicate that futures prices leads spot prices, and that futures contracts with longer time to expiration leads contracts with shorter time to expiration. (author)

  6. Physicochemical characteristics of the kanamycin-lyophilized kit

    International Nuclear Information System (INIS)

    Eva Maria Widyasari; Misyetti; Teguh Hafiz Ambar W; Witri Nuraeni

    2013-01-01

    Kanamycin is a broad-spectrum antibiotic and usually used for the treatment of infections when antibiotics like penicillin are less powerful and can not be given. This research was performed to obtain several physicochemical character of 99m Tc-kanamycin which were made in the form of lyophilized kanamycin kit to ensure the later application in humans. Kanamycin diagnostic kit were provided in lyophilized kit comprising kanamycin as ligand compound, pyrophosphate as co-ligand and SnCl 2 as reducing agent. The radiochemical purity was determined by instant thin layer chromatography (ITLC-SG) using 0.5 N NaOH as the mobile phase and ascending paper chromatography using Whatman paper 3 with acetone as the mobile phase. The plasma binding protein of 99m Tc-kanamycin was investigated in vitro by precipitation method using 5% of trichloro acetic acid (TCA) solution, whereas the lipophilicity (log P) was obtained by determination the partition coefficient in organic solvent-water system. Studies on the effect of the amount of radioactivity and the volume of Na 99m TcO 4 solution to the radiochemical purity of 99m Tc-kanamycin were also performed. From this experiment it was obtained that kanamycin lyophilized-kit was hydrophilic, 59.54% of solutions bound to plasma, radiochemical purity was more than 95%, and the final volume of 2 ml dosage was stable up to 2 hours after the addition of 99m Tc with a radioactivity of less then 3 mCi. (author)

  7. TEVA-SPOT-GUI - Containing Preliminary Flow Model

    Data.gov (United States)

    U.S. Environmental Protection Agency — This ZIP file contains the developmental, test version of TEVA-SPOT-GUI's Flow Model. The Flow Model is a new, event based water quality algorithm for EPANET. The...

  8. To Kit or Not to Kit? Evaluating and Implementing Science Materials and Resources

    Science.gov (United States)

    Schiller, Ellen; Melin, Jacque; Bair, Mary

    2016-01-01

    With the release of the "Next Generation Science Standards," many schools are reexamining the science materials they are using. Textbook companies and kit developers are eager to meet the demand for "NGSS"-aligned teaching materials. Teacher may have been asked to serve on a science curriculum committee, or to evaluate current…

  9. Recurrent star-spot activity and differential rotation in KIC 11560447

    Science.gov (United States)

    Özavcı, I.; Şenavcı, H. V.; Işık, E.; Hussain, G. A. J.; O'Neal, D.; Yılmaz, M.; Selam, S. O.

    2018-03-01

    We present a detailed analysis of surface inhomogeneities on the K1-type subgiant component of the rapidly rotating eclipsing binary KIC 11560447, using high-precision Kepler light curves spanning nearly 4 yr, which corresponds to about 2800 orbital revolutions. We determine the system parameters precisely, using high-resolution spectra from the 2.1-m Otto Struve Telescope at the McDonald Observatory. We apply the maximum entropy method to reconstruct the relative longitudinal spot occupancy. Our numerical tests show that the procedure can recover large-scale random distributions of individually unresolved spots, and it can track the phase migration of up to three major spot clusters. By determining the drift rates of various spotted regions in orbital longitude, we suggest a way to constrain surface differential rotation and we show that the results are consistent with periodograms. The K1IV star exhibits two mildly preferred longitudes of emergence, indications of solar-like differential rotation, and a 0.5-1.3-yr recurrence period in star-spot emergence, accompanied by a secular increase in the axisymmetric component of spot occupancy.

  10. Canine and human gastrointestinal stromal tumors display similar mutations in c-KIT exon 11

    International Nuclear Information System (INIS)

    Gregory-Bryson, Emmalena; Bartlett, Elizabeth; Kiupel, Matti; Hayes, Schantel; Yuzbasiyan-Gurkan, Vilma

    2010-01-01

    Gastrointestinal stromal tumors (GISTs) are common mesenchymal neoplasms in the gastrointestinal tract of humans and dogs. Little is known about the pathogenesis of these tumors. This study evaluated the role of c-KIT in canine GISTs; specifically, we investigated activating mutations in exons 8, 9, 11, 13, and 17 of c-KIT and exons 12, 14, and 18 of platelet-derived growth factor receptor, alpha polypeptide (PDGFRA), all of which have been implicated in human GISTs. Seventeen canine GISTs all confirmed to be positive for KIT immunostaining were studied. Exons 8, 9, 11, 13 and 17 of c-KIT and exons 12, 14, and 18 of PDGFRA, were amplified from DNA isolated from formalin-fixed paraffin-embedded samples. Of these seventeen cases, six amplicons of exon 11 of c-KIT showed aberrant bands on gel electrophoresis. Sequencing of these amplicons revealed heterozygous in-frame deletions in six cases. The mutations include two different but overlapping six base pair deletions. Exons 8, 9, 13, and 17 of c-KIT and exons 12, 14, and 18 of PDGFRA had no abnormalities detected by electrophoresis and sequencing did not reveal any mutations, other than synonymous single nucleotide polymorphisms (SNPs) found in exon 11 of c-KIT and exons 12 and 14 of PDGFRA. The deletion mutations detected in canine GISTs are similar to those previously found in the juxtamembrane domain of c-KIT in canine cutaneous mast cell tumors in our laboratory as well as to those reported in human GISTs. Interestingly, none of the other c-KIT or PDGFRA exons showed any abnormalities in our cases. This finding underlines the critical importance of c-KIT in the pathophysiology of canine GISTs. The expression of KIT and the identification of these activating mutations in c-KIT implicate KIT in the pathogenesis of these tumors. Our results indicate that mutations in c-KIT may be of prognostic significance and that targeting KIT may be a rational approach to treatment of these malignant tumors. This study further

  11. Relationship between hot spot residues and ligand binding hot spots in protein-protein interfaces.

    Science.gov (United States)

    Zerbe, Brandon S; Hall, David R; Vajda, Sandor; Whitty, Adrian; Kozakov, Dima

    2012-08-27

    In the context of protein-protein interactions, the term "hot spot" refers to a residue or cluster of residues that makes a major contribution to the binding free energy, as determined by alanine scanning mutagenesis. In contrast, in pharmaceutical research, a hot spot is a site on a target protein that has high propensity for ligand binding and hence is potentially important for drug discovery. Here we examine the relationship between these two hot spot concepts by comparing alanine scanning data for a set of 15 proteins with results from mapping the protein surfaces for sites that can bind fragment-sized small molecules. We find the two types of hot spots are largely complementary; the residues protruding into hot spot regions identified by computational mapping or experimental fragment screening are almost always themselves hot spot residues as defined by alanine scanning experiments. Conversely, a residue that is found by alanine scanning to contribute little to binding rarely interacts with hot spot regions on the partner protein identified by fragment mapping. In spite of the strong correlation between the two hot spot concepts, they fundamentally differ, however. In particular, while identification of a hot spot by alanine scanning establishes the potential to generate substantial interaction energy with a binding partner, there are additional topological requirements to be a hot spot for small molecule binding. Hence, only a minority of hot spots identified by alanine scanning represent sites that are potentially useful for small inhibitor binding, and it is this subset that is identified by experimental or computational fragment screening.

  12. Epigenetic regulation of cardiac progenitor cells marker c-kit by stromal cell derived factor-1α.

    Directory of Open Access Journals (Sweden)

    Zhongpu Chen

    Full Text Available BACKGROUND: Cardiac progenitor cells (CPCs have been proven suitable for stem cell therapy after myocardial infarction, especially c-kit(+CPCs. CPCs marker c-kit and its ligand, the stem cell factor (SCF, are linked as c-kit/SCF axis, which is associated with the functions of proliferation and differentiation. In our previous study, we found that stromal cell-derived factor-1α (SDF-1α could enhance the expression of c-kit. However, the mechanism is unknown. METHODS AND RESULTS: CPCs were isolated from adult mouse hearts, c-kit(+ and c-kit(- CPCs were separated by magnetic beads. The cells were cultured with SDF-1α and CXCR4-selective antagonist AMD3100, and c-kit expression was measured by qPCR and Western blotting. Results showed that SDF-1α could enhance c-kit expression of c-kit(+CPCs, made c-kit(-CPCs expressing c-kit, and AMD3100 could inhibit the function of SDF-1α. After the intervention of SDF-1α and AMD3100, proliferation and migration of CPCs were measured by CCK-8 and transwell assay. Results showed that SDF-1α could enhance the proliferation and migration of both c-kit(+ and c-kit(- CPCs, and AMD3100 could inhibit these functions. DNA methyltransferase (DNMT mRNA were measured by qPCR, DNMT activity was measured using the DNMT activity assay kit, and DNA methylation was analyzed using Sequenom's MassARRAY platform, after the CPCs were cultured with SDF-1α. The results showed that SDF-1α stimulation inhibited the expression of DNMT1 and DNMT3β, which are critical for the maintenance of regional DNA methylation. Global DNMT activity was also inhibited by SDF-1α. Lastly, SDF-1α treatment led to significant demethylation in both c-kit(+ and c-kit(- CPCs. CONCLUSIONS: SDF-1α combined with CXCR4 could up-regulate c-kit expression of c-kit(+CPCs and make c-kit(-CPCs expressing c-kit, which result in the CPCs proliferation and migration ability improvement, through the inhibition of DNMT1 and DNMT3β expression and global DNMT

  13. SPOT Program

    Science.gov (United States)

    Smith, Jason T.; Welsh, Sam J.; Farinetti, Antonio L.; Wegner, Tim; Blakeslee, James; Deboeck, Toni F.; Dyer, Daniel; Corley, Bryan M.; Ollivierre, Jarmaine; Kramer, Leonard; hide

    2010-01-01

    A Spacecraft Position Optimal Tracking (SPOT) program was developed to process Global Positioning System (GPS) data, sent via telemetry from a spacecraft, to generate accurate navigation estimates of the vehicle position and velocity (state vector) using a Kalman filter. This program uses the GPS onboard receiver measurements to sequentially calculate the vehicle state vectors and provide this information to ground flight controllers. It is the first real-time ground-based shuttle navigation application using onboard sensors. The program is compact, portable, self-contained, and can run on a variety of UNIX or Linux computers. The program has a modular objec-toriented design that supports application-specific plugins such as data corruption remediation pre-processing and remote graphics display. The Kalman filter is extensible to additional sensor types or force models. The Kalman filter design is also strong against data dropouts because it uses physical models from state and covariance propagation in the absence of data. The design of this program separates the functionalities of SPOT into six different executable processes. This allows for the individual processes to be connected in an a la carte manner, making the feature set and executable complexity of SPOT adaptable to the needs of the user. Also, these processes need not be executed on the same workstation. This allows for communications between SPOT processes executing on the same Local Area Network (LAN). Thus, SPOT can be executed in a distributed sense with the capability for a team of flight controllers to efficiently share the same trajectory information currently being computed by the program. SPOT is used in the Mission Control Center (MCC) for Space Shuttle Program (SSP) and International Space Station Program (ISSP) operations, and can also be used as a post -flight analysis tool. It is primarily used for situational awareness, and for contingency situations.

  14. Mutations in MITF and PAX3 Cause “Splashed White” and Other White Spotting Phenotypes in Horses

    Science.gov (United States)

    Blatter, Marlis; Brooks, Samantha A.; Burger, Dominik; Drögemüller, Cord; Gerber, Vincent; Henke, Diana; Janda, Jozef; Jude, Rony; Magdesian, K. Gary; Matthews, Jacqueline M.; Poncet, Pierre-André; Svansson, Vilhjálmur; Tozaki, Teruaki; Wilkinson-White, Lorna; Penedo, M. Cecilia T.; Rieder, Stefan; Leeb, Tosso

    2012-01-01

    During fetal development neural-crest-derived melanoblasts migrate across the entire body surface and differentiate into melanocytes, the pigment-producing cells. Alterations in this precisely regulated process can lead to white spotting patterns. White spotting patterns in horses are a complex trait with a large phenotypic variance ranging from minimal white markings up to completely white horses. The “splashed white” pattern is primarily characterized by an extremely large blaze, often accompanied by extended white markings at the distal limbs and blue eyes. Some, but not all, splashed white horses are deaf. We analyzed a Quarter Horse family segregating for the splashed white coat color. Genome-wide linkage analysis in 31 horses gave a positive LOD score of 1.6 in a region on chromosome 6 containing the PAX3 gene. However, the linkage data were not in agreement with a monogenic inheritance of a single fully penetrant mutation. We sequenced the PAX3 gene and identified a missense mutation in some, but not all, splashed white Quarter Horses. Genome-wide association analysis indicated a potential second signal near MITF. We therefore sequenced the MITF gene and found a 10 bp insertion in the melanocyte-specific promoter. The MITF promoter variant was present in some splashed white Quarter Horses from the studied family, but also in splashed white horses from other horse breeds. Finally, we identified two additional non-synonymous mutations in the MITF gene in unrelated horses with white spotting phenotypes. Thus, several independent mutations in MITF and PAX3 together with known variants in the EDNRB and KIT genes explain a large proportion of horses with the more extreme white spotting phenotypes. PMID:22511888

  15. Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.

    Science.gov (United States)

    Liu, Jason Yingjie

    2014-11-01

    The effectiveness of a direct quantification assay is essential to the adoption of the combined direct quantification/direct STR workflow. In this paper, the feasibility of using the Quantifiler(®) Trio DNA quantification kit for the direct quantification of forensic casework samples was investigated. Both low-level touch DNA samples and blood samples were collected on PE swabs and quantified directly. The increased sensitivity of the Quantifiler(®) Trio kit enabled the detection of less than 10pg of DNA in unprocessed touch samples and also minimizes the stochastic effect experienced by different targets in the same sample. The DNA quantity information obtained from a direct quantification assay using the Quantifiler(®) Trio kit can also be used to accurately estimate the optimal input DNA quantity for a direct STR amplification reaction. The correlation between the direct quantification results (Quantifiler(®) Trio kit) and the direct STR results (GlobalFiler™ PCR amplification kit(*)) for low-level touch DNA samples indicates that direct quantification using the Quantifiler(®) Trio DNA quantification kit is more reliable than the Quantifiler(®) Duo DNA quantification kit for predicting the STR results of unprocessed touch DNA samples containing less than 10pg of DNA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. [Development and evaluation of a rapid PCR detection kit for Ophiocordyceps sinensis].

    Science.gov (United States)

    Hou, Fei-Xia; Cao, Jing; Wang, Sha-Sha; Wang, Xi; Yuan, Yuan; Peng, Cheng; Wan, De-Guang; Guo, Jin-Lin

    2017-03-01

    Ophiocordyceps sinensis is a valuable traditional Chinese medicine. Due to resource shortage, expensive price and huge market demand, there are many adulterants of O. sinensis in markets. Therefore, it is necessary to establish a rapid and effective method for distinguishing O. sinensis. Based on the species-specific PCR of O. sinensis, this study developed a detection kit by optimizing the components and evaluated the specificity, detection limit, repeatability and shelf life of the kit. The results showed that when the quality of O. sinensis accounted for more than 1/200 of that mixture, it could be detected successfully. Moreover, only O. sinensis could be amplified and glowed bright green fluorescence under ultraviolet light. The kit was still in effect when it was placed at 37 ℃ for three days, which indicated that it was stable and effective for one year stored in 4 ℃. The kit in the same batch under different operation conditions, and in different batch under the same operation conditions gave the same result and accuracy, which showed good repeatability of the kit. It is simple, rapid and accurate to distinguish O. sinensis from its adulterants using the kit, and lays the foundation for commercialization of traditional Chinese medicine fast detection kit. Copyright© by the Chinese Pharmaceutical Association.

  17. Perceptions of point-of-care infectious disease testing among European medical personnel, point-of-care test kit manufacturers, and the general public

    Directory of Open Access Journals (Sweden)

    Kaman WE

    2013-06-01

    specialists and POC test kit manufacturers. The general public was much more favorable with respect to a perceived improvement in the quality of healthcare that these tests would bring to the hospital and home environment.Keywords: Survey, questionnaire, point-of-care, microbial diagnosis

  18. An Investigation on Hot-Spot Temperature Calculation Methods of Power Transformers

    OpenAIRE

    Ahmet Y. Arabul; Ibrahim Senol; Fatma Keskin Arabul; Mustafa G. Aydeniz; Yasemin Oner; Gokhan Kalkan

    2016-01-01

    In the standards of IEC 60076-2 and IEC 60076-7, three different hot-spot temperature estimation methods are suggested. In this study, the algorithms which used in hot-spot temperature calculations are analyzed by comparing the algorithms with the results of an experimental set-up made by a Transformer Monitoring System (TMS) in use. In tested system, TMS uses only top oil temperature and load ratio for hot-spot temperature calculation. And also, it uses some constants from standards which ar...

  19. Validation and use of an ELISA kit for the diagnosis of Babesia bovis in Cuba

    International Nuclear Information System (INIS)

    Blandino, T.; Alonso, M.; Barrera, M.; Mendoza, E.

    1998-01-01

    Babesia bovis, the most important etiological agent causing bovine babesiosis, is widely distributed in Cuba and affects mainly adult cattle. A survey of the prevalence of the disease in cattle using an ELISA kit (FAO/IAEA) revealed that 34.2% of the animals between 6 and 18 months of age were positive to Babesia bovis, whereas 69.9% on the cattle older than 18 months were positive. Antibodies to Babesia bovis were detected in 96.9% of calves vaccinated with an attenuated Babesia bovis vaccine. A good correlation was found between the results of ELISA kit with those from indirect immunofluorescence and immunoperoxidase tests developed in Cuba. (author)

  20. Comparison of commercial exosome isolation kits for circulating exosomal microRNA profiling.

    Science.gov (United States)

    Ding, Meng; Wang, Cheng; Lu, Xiaolan; Zhang, Cuiping; Zhou, Zhen; Chen, Xi; Zhang, Chen-Yu; Zen, Ke; Zhang, Chunni

    2018-06-01

    Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. Here, we analyzed the advantages and weaknesses of four commonly used commercial kits for exosomal miRNA profiling and their application to the sample of serum and/or plasma, respectively. NanoSight and Western blotting were conducted to evaluate the efficiency and purity of the isolated exosomes. In our conditions, the size distribution of the isolated particles was appropriate (40-150 nm), and ExoQuick™ Exosome Precipitation Solution (EXQ) generated a relatively high yield of exosomes. Nevertheless, albumin impurity was ubiquitous for all the four kits, and Total Exosome Isolation for serum or plasma (TEI) yielded a relatively pure isolation. We further performed Illumina sequencing combined with RT-qPCR to determine the ability of these kits for miRNA profiling. There was significant correlation of the exosomal miRNA profile and specific miRNAs between kits, but with differences depending on methods. exoRNeasy Serum/Plasma Midi Kit (EXR) and EXQ performed better in the specific exosomal miRNAs recovery. Intraassay CVs for specific miRNA measurement were 0.88-3.82, 1.19-3.77, 0-2.70, and 1.23-9.11% for EXR, TEI, EXQ, and RIBO™ Exosome Isolation Reagent (REI), respectively. In each kit, serum yielded a higher abundance of exosomes and exosomal miRNAs than plasma, yet with more albumin impurity. In conclusion, our data provide some valuable guidance for the methodology of disease biomarker identification of circulation exosomal miRNAs. Graphical abstract Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. In this study, we compared four commonly used commercially available kits for exosomal mi

  1. Application of X-ray CCD camera in X-ray spot diagnosis of rod-pinch diode

    International Nuclear Information System (INIS)

    Song Yan; Zhou Ming; Song Guzhou; Ma Jiming; Duan Baojun; Han Changcai; Yao Zhiming

    2015-01-01

    The pinhole imaging technique is widely used in the measurement of X-ray spot of rod-pinch diode. The X-ray CCD camera, which was composed of film, fiber optic taper and CCD camera, was employed to replace the imaging system based on scintillator, lens and CCD camera in the diagnosis of X-ray spot. The resolution of the X-ray CCD camera was studied. The resolution is restricted by the film and is 5 lp/mm in the test with Pb resolution chart. The frequency is 1.5 lp/mm when the MTF is 0.5 in the test with edge image. The resolution tests indicate that the X-ray CCD camera can meet the requirement of the diagnosis of X-ray spot whose scale is about 1.5 mm when the pinhole imaging magnification is 0.5. At last, the image of X-ray spot was gained and the restoration was implemented in the diagnosis of X-ray spot of rod-pinch diode. (authors)

  2. Normalization with Corresponding Naïve Tissue Minimizes Bias Caused by Commercial Reverse Transcription Kits on Quantitative Real-Time PCR Results.

    Directory of Open Access Journals (Sweden)

    Andreas Garcia-Bardon

    Full Text Available Real-time reverse transcription polymerase chain reaction (PCR is the gold standard for expression analysis. Designed to improve reproducibility and sensitivity, commercial kits are commonly used for the critical step of cDNA synthesis. The present study was designed to determine the impact of these kits. mRNA from mouse brains were pooled to create serial dilutions ranging from 0.0625 μg to 2 μg, which were transcribed into cDNA using four different commercial reverse-transcription kits. Next, we transcribed mRNA from brain tissue after acute brain injury and naïve mice into cDNA for qPCR. Depending on tested genes, some kits failed to show linear results in dilution series and revealed strong variations in cDNA yield. Absolute expression data in naïve and trauma settings varied substantially between these kits. Normalization with a housekeeping gene failed to reduce kit-dependent variations, whereas normalization eliminated differences when naïve samples from the same region were used. The study shows strong evidence that choice of commercial cDNA synthesis kit has a major impact on PCR results and, consequently, on comparability between studies. Additionally, it provides a solution to overcome this limitation by normalization with data from naïve samples. This simple step helps to compare mRNA expression data between different studies and groups.

  3. Development of an up-to-date NBC self-aid kit for emergency cases

    International Nuclear Information System (INIS)

    Mueller, Michael; Schmiechen, Katharina

    2009-01-01

    In accordance with alterations of the political and economical settings of Central Europe in the last decades, the characteristics of NBC hazards have changed. Since war appears unlikely, possible new scenarios involve pandemics, chemical transport accidents or distribution of CB warfare agents and radioactive materials by terroristic acts. Meeting this situation requires new protection and self aid equipment for the German civilian disaster relief forces. The German government has reacted to these risks by designing personal protection equipment for the civilian voluntary and professional disaster relief forces. The new NBC self aid kit will be part of this effort. The scientific approach of the project consisted of an updated risk analysis, a questionnaire for the professionals and volunteers involved in disaster management, a thorough evaluation of commercially available kits and single components, final design of the new kit including user instructions, and validation of a prototype kit in a disaster relief exercise. Results of the questionnaire stressed the need for a NBC self aid kit fulfilling the demands of easy handling, use of commercially available components, stability of materials, consumption adapted supply and portable size and weight of the complete kit. The evaluation of international NBC equipment could not identify any current NBC self aid kit which satisfies all needs of the German civilian disaster relief forces. The authors therefore compiled a new kit consisting of commercially available components. The newly developed kit was evaluated in a disaster relief exercise.

  4. Nuclear track detector kit for use in teaching

    Energy Technology Data Exchange (ETDEWEB)

    Medveczky, L.; Somogyi, G.; Nagy, M.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations.

  5. Evaluation and Characterization of The Radiopharmaceutical Lyophilized-Kit of Ciprofloxacin

    International Nuclear Information System (INIS)

    Nurlaila Zainuddin; Eva Maria Widyasari

    2009-01-01

    The 99m Tc-ciprofloxacin radiopharmaceutical is available in the lyophilized-kit which is separately packed in two vials, ciprofloxacin lactate and Sn-tartrate, respectively. Preparation of 99m Tc-ciprofloxacin was performed by adding 99m Tc radionuclide into ciprofloxacin lactate solution, followed by addition of Sn-tartrate solution. The complement information was needed by user in order to assure the successful preparation and utilization of this radiopharmaceutical. Meanwhile, this investigation was performed to obtained the several physicochemical and biological characters of 99m Tc-ciprofloxacin prepared from the radiopharmaceutical lyophilized-kit of ciprofloxacin lactate. The radiochemical purity was determined with instant thin layer chromatography (ITLC-SG) using acetone and solution of dichloromethane : methanol : ammonium hydroxide : acetonitrile : (4:4:2:1) as a mobile phases. The plasma binding protein of 99m Tc-ciprofloxacin was investigated in-vitro by precipitation method using 5% of trichloro acetic acid solution, whereas the lipophilicity (P) was obtained by determination of octanol-water partition. Beside that, studies on the effect of volume of Na 99m TcO4 solution to radiochemical purity of 99m Tc-ciprofloxacin has been carried out. From the experiment, it was obtained that 99m Tc-ciprofloxacin has 95.85 ± 2.10 % of radiochemical purity, the human plasma binding protein of 58.35 ± 2.05 % and the lipophilicity (P) = 0.024 ± 0.005. The volume more than 2 mL of Na 99m TcO4 solution on the labelling of ciprofloxacin gave less than 90 % of radiochemical purity. The labelling efficiency of 44.79 % was obtained after filtration of 99m Tc-ciprofloxacin. The stability test on 99m Tc-ciprofloxacin and ciprofloxacin lyophilized-kit were performed by determining their radiochemical purities. The 99m Tcciprofloxacin was still able to be used until 4 hours after labelling with radiochemical purity of 91.61 ± 1.60 %. The stability determination showed

  6. Yeast identification by sequencing, biochemical kits, MALDI-TOF MS and rep-PCR DNA fingerprinting.

    Science.gov (United States)

    Zhao, Ying; Tsang, Chi-Ching; Xiao, Meng; Chan, Jasper F W; Lau, Susanna K P; Kong, Fanrong; Xu, Yingchun; Woo, Patrick C Y

    2017-12-08

    No study has comprehensively evaluated the performance of 28S nrDNA and ITS sequencing, commercial biochemical test kits, MALDI-TOF MS platforms, and the emerging rep-PCR DNA fingerprinting technology using a cohort of yeast strains collected from a clinical microbiology laboratory. In this study, using 71 clinically important yeast isolates (excluding Candida albicans) collected from a single centre, we determined the concordance of 28S nrDNA and ITS sequencing and evaluated the performance of two commercial test kits, two MALDI-TOF MS platforms, and rep-PCR DNA fingerprinting. 28S nrDNA and ITS sequencing showed complete agreement on the identities of the 71 isolates. Using sequencing results as the standard, 78.9% and 71.8% isolates were correctly identified using the API 20C AUX and Vitek 2 YST ID Card systems, respectively; and 90.1% and 80.3% isolates were correctly identified using the Bruker and Vitek MALDI-TOF MS platforms, respectively. Of the 18 strains belonging to the Candida parapsilosis species complex tested by DiversiLab automated rep-PCR DNA fingerprinting, all were identified only as Candida parapsilosis with similarities ≥93.2%, indicating the misidentification of Candida metapsilosis and Candida orthopsilosis. However, hierarchical cluster analysis of the rep-PCR DNA fingerprints of these three species within this species complex formed three different discrete clusters, indicating that this technology can potentially differentiate the three species. To achieve higher accuracies of identification, the databases of commercial biochemical test kits, MALDI-TOF MS platforms, and DiversiLab automated rep-PCR DNA fingerprinting needs further enrichment, particularly for uncommonly encountered yeast species. © The Author 2017. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Improved kit formulation for preparation of (99m)Tc-HYNIC-TOC: results of preliminary clinical evaluation in imaging patients with neuroendocrine tumors.

    Science.gov (United States)

    Korde, Aruna; Mallia, Madhava; Shinto, Ajit; Sarma, H D; Samuel, Grace; Banerjee, Sharmila

    2014-11-01

    (99m)Tc-HYNIC-TOC is a cost-effective and logistically viable agent for scintigraphy of neuroendocrine tumors overexpressing somatostatin receptors as compared with [(111)In-DTPA-D-Phe(1)] Octreotide (Octreoscan(®)). Several studies have been reported, wherein the efficacy of this agent is demonstrated. In the present article, the authors report the preparation of a single-vial HYNIC-TOC kit suitable for the preparation of 4-5 patient doses (15 mCi/patient) of (99m)Tc-HYNIC-TOC. The kits were tested for sterility and bacterial endotoxins to assure safety of the product. A significant modification in this kit is the inclusion of buffer in the kit itself, unlike in commercially available kits where the buffer solution has to be added during preparation. (99m)Tc-HYNIC-TOC was prepared by adding 20-80 mCi (740-2960 MBq) of freshly eluted Na(99m)TcO4 in 1-3 mL of sterile saline directly into the kit vial and heating the vial in a water bath at 100°C for 20 minutes. The labeling yield and radiochemical purity of (99m)Tc-HYNIC-TOC, prepared using the lyophilized cold kit, were consistently >90%. The kits were evaluated over a period of 9 months and found to be stable when stored at -20°C. Limited clinical studies performed with the (99m)Tc-HYNIC-TOC, formulated using the kit, showed adequate sensitivity and specificity for the detection of gasteroenteropancreatic neuroendocrine tumors.

  8. Models of spots and flares

    International Nuclear Information System (INIS)

    Mullan, D.J.

    1983-01-01

    Laboratory experiments in recent years have shown that there are many more ways to drive a plasma out of equilibrium than to preserve equilibrium. In that sense, it is perhaps easier to understand why flares should occur in a stellar atmosphere than why a long-lived feature such as a dark spot should persist. The author summarizes work on the equilibrium structure of cool spots in the sun and stars. Since spots involve complex interactions between convective flows and magnetic fields, he needs to refer to observations for help in identifying the dominant processes which should enter into the modelling. His summary therefore begins by discussing certain relevant properties of spots in the solar atmosphere. The next sections deal with the magnetic fields in spots, the stability of spots, spot cooling and missing flux. The author concludes that spots should be viewed not simply as cool areas, but rather as engines which do the work of converting the energy of convective flows into flare-compatible form. (Auth.)

  9. Extravasation of contrast (Spot Sign) predicts in-hospital mortality in ruptured arteriovenous malformation.

    Science.gov (United States)

    Ye, Zengpanpan; Ai, Xiaolin; Zheng, Jun; Hu, Xin; You, Chao; Andrew M, Faramand; Fang, Fang

    2017-10-09

    The spot sign is a highly specific and sensitive predictor of hematoma expansion in following primary intracerebral hemorrhage (ICH). Rare cases of the spot sign have been documented in patients with intracranial hemorrhage secondary to arteriovenous malformation (AVM). The purpose of this retrospective study is to assess the accuracy of spot sign in predicting clinical outcomes in patients with ruptured AVM. A retrospective analysis of a prospectively maintained database was performed for patients who presented to West China Hospital with ICH secondary to AVM in the period between January 2009 and September 2016. Two radiologists blinded to the clinical data independently assessed the imaging data, including the presence of spot sign. Statistical analysis using univariate testing, multivariate logistic regression testing, and receiver operating characteristic curve (AUC) analysis was performed. A total of 116 patients were included. Overall, 18.9% (22/116) of subjects had at least 1 spot sign detected by CT angiography, 7% (8/116) died in hospital, and 27% (31/116) of the patients had a poor outcome after 90 days. The spot sign had a sensitivity of 62.5% and specificity of 84.3% for predicting in-hospital mortality (p = .02, AUC 0.734). No correlation detected between the spot sign and 90-day outcomes under multiple logistic regression (p = .19). The spot sign is an independent predictor for in-hospital mortality. The presence of spot sign did not correlate with the 90 day outcomes in this patient cohort. The results of this report suggest that patients with ruptured AVM with demonstrated the spot sign on imaging must receive aggressive treatment early on due to the high risk of mortality.

  10. The SPOT-HRV instrument - An overview of design and performance

    Science.gov (United States)

    Midan, J. P.

    1983-10-01

    The SPOT spacecraft's High Visible Resolution (HVR) earth resources sensor performance requirements, system and subsystem design features, and technology development considerations, are discussed. Attention is given to such problem areas involving extensive design tradeoff analyses and testing as those uncovered by mechanical design and thermal distortion studies and SNR analysis and calibration considerations. The SPOT spacecraft will be placed in orbit in 1985.

  11. Avoiding Carbon Bed Hot Spots in Thermal Process Off-Gas Systems

    International Nuclear Information System (INIS)

    Soelberg, Nick; Enneking, Joe

    2011-01-01

    Mercury has had various uses in nuclear fuel reprocessing and other nuclear processes, and so is often present in radioactive and mixed (radioactive and hazardous) wastes. Test programs performed in recent years have shown that mercury in off-gas streams from processes that treat radioactive wastes can be controlled using fixed beds of activated sulfur-impregnated carbon, to levels low enough to comply with air emission regulations such as the Hazardous Waste Combustor (HWC) Maximum Achievable Control Technology (MACT) standards. Carbon bed hot spots or fires have occurred several times during these tests, and also during a remediation of tanks that contained mixed waste. Hot spots occur when localized areas in a carbon bed become heated to temperatures where oxidation occurs. This heating typically occurs due to heat of absorption of gas species onto the carbon, but it can also be caused through external means such as external heaters used to heat the carbon bed vessel. Hot spots, if not promptly mitigated, can grow into bed fires. Carbon bed hot spots and fires must be avoided in processes that treat radioactive and mixed waste. Hot spots are detected by (a) monitoring in-bed and bed outlet gas temperatures, and (b) more important, monitoring of bed outlet gas CO concentrations. Hot spots are mitigated by (a) designing for appropriate in-bed gas velocity, for avoiding gas flow maldistribution, and for sufficient but not excessive bed depth, (b) appropriate monitoring and control of gas and bed temperatures and compositions, and (c) prompt implementation of corrective actions if bed hot spots are detected. Corrective actions must be implemented quickly if bed hot spots are detected, using a graded approach and sequence starting with corrective actions that are simple, quick, cause the least impact to the process, and are easiest to recover from.

  12. Technetium-99m ceftizoxime kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento [Minas Gerais Univ. Federal, Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Martin-Comin, Josep [Bellvitge Univ., Barcelona (Spain)

    2005-10-15

    The aim of this work was to prepare a kit of {sup 99}m Tc-ceftizoxime ({sup 99m} Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium {sup 99m} Tc pertechnetate solution (Na {sup 99m} Tc O{sub 4-}) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the {sup 99m} Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of {sup 99m} Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for {sup 99}m Tc-CFT were 27.16 {+-} 0.23 and 27.17 {+-} 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 {+-} 0.33 and 29.43 {+-} 0.26, respectively. The results for the biodistribution of {sup 99m} Tc-CFT in infected animals furnished a ratio of 1.97 {+-} 0.31, 2.10 {+-} 0.42 and 2.01 {+-} 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ({sup 99m} Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with {sup 99m} technetium-labeled ceftizoxime for the

  13. Homologous recombination induced by doxazosin mesylate and saw palmetto in the Drosophila wing-spot test.

    Science.gov (United States)

    Gabriel, Katiane Cella; Dihl, Rafael Rodrigues; Lehmann, Mauricio; Reguly, Maria Luiza; Richter, Marc François; Andrade, Heloisa Helena Rodrigues de

    2013-03-01

    Benign prostatic hyperplasia (BPH) is the most common tumor in men over 40 years of age. Acute urinary retention (AUR) is regarded as the most serious hazard of untreated BPH. α-Blockers, such as doxazosin mesylate, and 5-α reductase inhibitors, such as finasteride, are frequently used because they decrease both AUR and the need for BPH-related surgery. An extract of the fruit from American saw palmetto plant has also been used as an alternative treatment for BPH. The paucity of information available concerning the genotoxic action of these compounds led us to assess their activity as inducers of different types of DNA lesions using the somatic mutation and recombination test in Drosophila melanogaster. Finasteride did not induce gene mutation, chromosomal mutation or mitotic recombination, which means it was nongenotoxic in our experimental conditions. On the other hand, doxazosin mesylate and saw palmetto induced significant increases in spot frequencies in trans-heterozygous flies. In order to establish the actual role played by mitotic recombination and by mutation in the genotoxicity observed, the balancer-heterozygous flies were also analyzed, showing no increment in the total spot frequencies in relation to the negative control, for both drugs. Doxazosin mesylate and saw palmetto were classified as specific inducers of homologous recombination in Drosophila proliferative cells, an event linked to the loss of heterozygosity. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Radioimmunoassay of surface antigen and core antibody of hepatitis B virus. Comparison of kits AUSRIA/CORE; AUSRIA II-125 and CORAB

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J [Ustav Hematologie a Krevni Transfuze, Prague (Czechoslovakia)

    1984-08-01

    The sensitivity is compared of determination of surface antigen HBsAg and nuclear antibody HBcAb of the hepatitis B virus using kits for separate (AUSRIA II-125, CORAB) and simultaneous (AUSRIAsup(R)/CORE) determinations of third generation tests in selected samples of medical personnel, HBsAg carriers, patients at a dialysis centre, blood donors and in sera of HBsAg carriers diluted in steps from 4x10/sup -2/ to 4x10/sup -7/. HBsAg is always determined using the RIA technique, HBcAb is determined using the technique of radioimmunoassay with the CORAB kit and with the AUSRIA sup(R)/CORE kit using enzymeimmunoassay. The sensitivity of determination using the AUSRIA sup(R)/CORE kit is at least as good for both investigated indicators of the hepatitis B virus and that obtained using separate determination of HBsAg (AUSRIA II-125) and HBcAb (CORAB), this also using modified photocolorimetric determination. Only one AUSRIA/sup R//CORE kit was available for the investigation and the informative character of the report is emphasized.

  15. Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy

    International Nuclear Information System (INIS)

    Hyer, Daniel E; Hill, Patrick M; Wang, Dongxu; Smith, Blake R; Flynn, Ryan T

    2014-01-01

    The purpose of this work was to investigate the reduction in lateral dose penumbra that can be achieved when using a dynamic collimation system (DCS) for spot scanning proton therapy as a function of two beam parameters: spot size and spot spacing. This is an important investigation as both values impact the achievable dose distribution and a wide range of values currently exist depending on delivery hardware. Treatment plans were created both with and without the DCS for in-air spot sizes (σ air ) of 3, 5, 7, and 9 mm as well as spot spacing intervals of 2, 4, 6 and 8 mm. Compared to un-collimated treatment plans, the plans created with the DCS yielded a reduction in the mean dose to normal tissue surrounding the target of 26.2–40.6% for spot sizes of 3–9 mm, respectively. Increasing the spot spacing resulted in a decrease in the time penalty associated with using the DCS that was approximately proportional to the reduction in the number of rows in the raster delivery pattern. We conclude that dose distributions achievable when using the DCS are comparable to those only attainable with much smaller initial spot sizes, suggesting that the goal of improving high dose conformity may be achieved by either utilizing a DCS or by improving beam line optics. (note)

  16. On the origin of delta spots

    International Nuclear Information System (INIS)

    Tang, F.

    1983-01-01

    Mount Wilson sunspot drawings from 1966 through 1980 were used in conjunction with Hα filtergrams from Big Bear Solar Observatory to examine the origin of delta spots, spots with bipolar umbrae within one penumbra. Of the six cases we studied, five were formed by the union of non-paired spots. They are either shoved into one another by two neighboring growing bipoles or by a new spot born piggy-back style on an existing spot of opposite polarity. Proper motions of the growing spots take on curvilinear paths around one another to avoid a collision. This is the shear motion observed in delta spots (Tanaka, 1979). In the remaining case, the delta spot was formed by spots that emerged as a pair. Our findings indicate no intrinsic differences in the formation or the behavior between delta spots of normal magnetic configuration. (orig.)

  17. Phytotoxic properties of cnicin, a sesquiterpene lactone fromcentaurea maculosa (spotted knapweed).

    Science.gov (United States)

    Kelsey, R G; Locken, L J

    1987-01-01

    Water and solvent extracts from the aerial tissues ofCentaurea maculosa, spotted knapweed, inhibited the root growth of lettuce. Column chromatography and lettuce bioassay of a chloroform extract led to the isolation of cnicin, a sesquiterpene lactone. Pure cnicin was bioassayed at 0, 1, 2, 4, 6, 8, and 10 mg/5 ml water with lettuce, created wheatgrass, bluebunch wheatgrass, rough fescue, western larch, lodgepole pine, and spotted knapweed. Germination was inhibited at one or more concentrations for all species except lodgepole pine and spotted knapweed. Growth, particularly of the roots, was retarded between 1 and 4 mg of cnicin. Lettuce, bluebunch wheatgrass, and spotted knapweed were inhibited significantly at all concentrations tested.

  18. 125I-labeled radioimmunoassay kits for progesterone evaluated for use in an in vitro fertilization program

    International Nuclear Information System (INIS)

    Blight, L.F.; White, G.H.

    1983-01-01

    We have evaluated two commercially available 125 I radioimmunoassay kits (Diagnostic Products Corp., DPC; and Radioassay Systems Laboratories, RSL) for measurement of serum or plasma progesterone, to determine their suitability for use in in vitro fertilization programs. Both kits were suitably rapid for program requirements. Results by both were linear with concentration up to 60 nmol/L, and both had acceptable lower detection limits of 0.3 nmol/L. Kit-determined progesterone concentrations (y) for 100 patients' samples correlated well with results by our existing 3H radioimmunoassay method (y . 1.11x + 0.2, r . 0.965 for the DPC kit; y . 1.01x + 1.4, r . 0.974 for the RSL kit). Mean analytical recovery for the RSL kit was 116%, that for the DPC kit, 202%. Within-batch precision, expressed as the mean CV for three concentrations of progesterone, was 6.5% for the RSL kit, and 16.4% for the DPC kit; between-day CV was 8.1% for the RSL kit, 17.7% for the DPC kit. We conclude that the RSL kit provides a rapid, precise, and accurate assay for serum progesterone, suitable for use in a fertilization program, but do not recommend the DPC kit for either this purpose or the more general purpose of tracking menstrual cycles

  19. Determination of Sn in 99mTc Radiopharmaceutical Kits by Polarographic Methods

    International Nuclear Information System (INIS)

    Castro, M.; Cruz, J.; Sanchez, M.

    2009-01-01

    Kits of 99 m Tc radiopharmaceuticals are used in nuclear medicine for diagnosis of different diseases. Sn (II) is one of the essential components in their formulations, which is used for reduction 99 m Tc-pertechnetate in cold kits for on-site preparation 99 m Tc-pertechnetate radiopharmaceuticals. Usually, these cold kits contain different additives (complexing agents, antioxidants, buffers, etc.) and the amount of Sn (II) varies from kit to kit. The determination of Sn in these products is essential in assessing their quality. We report here the development of a new polarographic method for the determination of Sn (II) and total Sn in representative radiopharmaceuticals kits (for the content of Sn and chemical composition) produced at the Center of Isotopes of Cuba (CENTIS). These methods were validated by analysis of variance and recovery techniques. From the results of the validation, the characteristic functions of uncertainties and fits are considered for the established methods, which give the necessary evidences to demonstrate the usefulness of these methods according to the current trends in Analytical Chemistry. This work provides practical results of great importance for CENTIS. After the speciation of Sn in the MAG3 radiopharmaceuticals kit is inferred that the production process is affected by uncontrolled factors that influence in the product stability, which demonstrates the necessity for analytical tools for the characterization of products and processes. (Author) 57 refs.

  20. Personal radiotoxicological (first aid) kit

    International Nuclear Information System (INIS)

    Gachalyi, Andras; Gyulai, Gabor

    2014-01-01

    In recent years, with the spread of nuclear industrial activities, and the widespread use of radioactive materials and products the possibility of radionuclide contamination of humans and animals has significantly increased. During nuclear tests or reactor accidents, a large amount of radioactive materials may enter the environment which can contaminate the living environment (air, water, vegetation, soil), for a long period. This contamination may enter living organisms by inhalation, intake and ingestion, causing severe biological damage. As an example the Chernobyl reactor accident can be mentioned, where there was no possibility for the decorporation of isotopes, as there were no products available such as the 'RADISTOP'. To achieve appropriate decorporating (and decontaminating) treatment which is effective, it is highly recommendable to use a personal Radiotoxicological First Aid Kit (PRK) within the shortest possible time after internal contamination. This unit provides effective treatment to decorporate the most common incorporated fission products. (author)

  1. A No-Arbitrage Fractional Cointegration Model for Futures and Spot Daily Ranges

    DEFF Research Database (Denmark)

    Rossi, Eduardo; Santucci de Magistris, Paolo

    2013-01-01

    The no-arbitrage relation between futures and spot prices implies an analogous relation between futures and spot daily ranges. The long-memory features of the range-based volatility estimators are analyzed, and fractional cointegration is tested in a semi-parametric framework. In particular, the no...

  2. Mapping Sensory Spots for Moderate Temperatures on the Back of Hand

    OpenAIRE

    Fan Yang; Guixu Chen; Sikai Zhou; Danhong Han; Jingjing Xu; Shengyong Xu

    2017-01-01

    Thermosensation with thermoreceptors plays an important role in maintaining body temperature at an optimal state and avoiding potential damage caused by harmful hot or cold environmental temperatures. In this work, the locations of sensory spots for sensing moderate temperatures of 40–50 °C on the back of the hands of young Chinese people were mapped in a blind-test manner with a thermal probe of 1.0 mm spatial resolution. The number of sensory spots increased along with the testing temperatu...

  3. StochKit2: software for discrete stochastic simulation of biochemical systems with events.

    Science.gov (United States)

    Sanft, Kevin R; Wu, Sheng; Roh, Min; Fu, Jin; Lim, Rone Kwei; Petzold, Linda R

    2011-09-01

    StochKit2 is the first major upgrade of the popular StochKit stochastic simulation software package. StochKit2 provides highly efficient implementations of several variants of Gillespie's stochastic simulation algorithm (SSA), and tau-leaping with automatic step size selection. StochKit2 features include automatic selection of the optimal SSA method based on model properties, event handling, and automatic parallelism on multicore architectures. The underlying structure of the code has been completely updated to provide a flexible framework for extending its functionality. StochKit2 runs on Linux/Unix, Mac OS X and Windows. It is freely available under GPL version 3 and can be downloaded from http://sourceforge.net/projects/stochkit/. petzold@engineering.ucsb.edu.

  4. Failure mode transition in AHSS resistance spot welds. Part I. Controlling factors

    International Nuclear Information System (INIS)

    Pouranvari, M.; Marashi, S.P.H.

    2011-01-01

    Highlights: → Interfacial to pullout failure mode transition for AHSS RSWs is studied. → An analytical mode is proposed to predict failure mode of AHSS RSWs. → Hardness characteristics of RSWs plays key role in the failure mode transition. - Abstract: Failure mode of resistance spot welds is a qualitative indicator of weld performance. Two major types of spot weld failure are pull-out and interfacial fracture. Interfacial failure, which typically results in reduced energy absorption capability, is considered unsatisfactory and industry standards are often designed to avoid this occurrence. Advanced High Strength Steel (AHSS) spot welds exhibit high tendency to fail in interfacial failure mode. Sizing of spot welds based on the conventional recommendation of 4t 0.5 (t is sheet thickness) does not guarantee the pullout failure mode in many cases of AHSS spot welds. Therefore, a new weld quality criterion should be found for AHSS resistance spot welds to guarantee pull-out failure. The aim of this paper is to investigate and analyze the transition between interfacial and pull-out failure modes in AHSS resistance spot welds during the tensile-shear test by the use of analytical approach. In this work, in the light of failure mechanism, a simple analytical model is presented for estimating the critical fusion zone size to prevent interfacial fracture. According to this model, the hardness ratio of fusion zone to pull-out failure location and the volume fraction of voids in fusion zone are the key metallurgical factors governing type of failure mode of AHSS spot welds during the tensile-shear test. Low hardness ratio and high susceptibility to form shrinkage voids in the case of AHSS spot welds appear to be the two primary causes for their high tendency to fail in interfacial mode.

  5. Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements

    International Nuclear Information System (INIS)

    Park, Seung Chul; Hwang, Tae Won; Moon, Chan Kook

    2008-01-01

    Metal filter elements were newly introduced to the high temperature filter (HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  6. GossipKit: A Framework of Gossip Protocol Family

    OpenAIRE

    Lin, Shen; Taiani, Francois; Blair, Gordon S.

    2007-01-01

    A large number of gossip protocols have been developed in the last few years to address a wide range of functionalities. So far, however, very few software frameworks have been proposed to ease the development and deployment of these gossip protocols. To address this issue, this paper presents GossipKit, an event-driven framework that provides a generic and extensible architecture for the development of (re)configurable gossip-oriented middleware. GossipKit is based on a generic interaction m...

  7. Telescope Kits: A Teaching Vehicle for the International Year of Astronomy

    Science.gov (United States)

    Pompea, Stephen M.; Fienberg, R. T.; Isbell, D.; Deustua, S.

    2007-12-01

    We are examining a variety of telescope kits suitable for assembly by school-age children in order to design a cornerstone educational program for the International Year of Astronomy 2009-400 years after Galileo's observations. In our experience, telescope kits are superior to pre-assembled telescopes for use in an educational setting as the students feels a stronger sense of ownership and have a better understanding of the components and how they work. We examined several low to medium power refracting telescope kits including one kit used in the Hands-On Optics project at NOAO. We describe the advantages and disadvantages of each kit from an educational and optical perspective and what modifications may be made to enhance their educational utility. We also describe the optical and education requirements for a low-powered "Galileoscope", to be distributed widely during the IYA. We also describe how the "Galileoscope” will be embedded in an educational program disseminated through science centers, amateur astronomy clubs and other Hands-On Optics centers and partners.

  8. Nuclear track detector kit for use in teaching

    International Nuclear Information System (INIS)

    Medveczky, L.; Somogyi, G.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations. (author)

  9. A nuclear source: a resource kit for teachers

    International Nuclear Information System (INIS)

    Hawkins, Gay.

    1992-01-01

    The aim of this Resource Kit is to provide information, diagrams, overheads and classroom activities, set in an Australian context, to broaden and enrich the teaching of nuclear science from both technical and social science aspects. It has been written to address the the Australian secondary school syllabuses and reflects this in both its format and contents. Emphasis has been given to the applications of nuclear physics to our lives today, from new medical diagnostic techniques to efficient methods of monitoring our own environment. This Resource Kit is a valuable source of information not readily available to teachers from textbooks. It provides a unique opportunity to present the picture in Australia, making us all more aware of Australia's front line in Australia, making us all more aware of Australia's front line role in nuclear research. The kit is meant to be used in conjunction with current textbooks, to complement and enrich them. The kit begins with a review of the many applications of nuclear science in order to provide a broad concrete base to motivate students to discover more of the specific details of the basic discoveries contained in the later sections. Topics such as the Structure of the Atom, which are well documented in textbooks, have been approached in a more creative and less rigorous manner to give teachers a fresh approach to the topic. The kit is divided into 10 separate sections and presented in loose-leaf form to facilitate its use in the classroom. Diagrams are inserted into the text to clarify and enrich descriptions, as well as being provided at the back of each section as black line masters for photocopying and overhead projections. ills., tabs

  10. Tool Kit Helps Digitize Tide Gauge Records

    Science.gov (United States)

    Ullmann, Albin; Pons, Frédéric; Moron, Vincent

    2005-09-01

    The Numérisation des Niveaux d'Eau (NUNIEAU) is an integrated and automated MATLAB computer program tool kit for digitizing, transforming, and validating paper records of sea level variations, called marigrams (Figure 1a), that can cut in half the time required to digitize paper records. This tool kit developed in 2004 by F. Pons is currently obtainable by request from the developer, but will be available online on the IMPLIT (Impact des événements extremes sur les hydro-systèmes du litoral méditerranéen français) Web site in early 2006.

  11. Spot market for uranium

    International Nuclear Information System (INIS)

    Colhoun, C.

    1982-01-01

    The spot market is always quoted for the price of uranium because little information is available about long-term contracts. A review of the development of spot market prices shows the same price curve swings that occur with all raw materials. Future long-term contracts will probably be lower to reflect spot market prices, which are currently in the real-value range of $30-$35. An upswing in the price of uranium could come in the next few months as utilities begin making purchases and trading from stockpiles. The US, unlike Europe and Japan, has already reached a supply and demand point where the spot market share is increasing. Forecasters cannot project the market price, they can only predict the presence of an oscillating spot or a secondary market. 5 figures

  12. Bearing Capacity of Resistance Spot Welding Under Conditions of Europe, Indonesia

    Directory of Open Access Journals (Sweden)

    Miroslav Müller

    2015-01-01

    Full Text Available A common attribute of production companies is a requirement for a bond creation. A resistance spot welding is a prospective method of bonding. An effect determination of environmental influences on mechanical properties of resistance spot welded bonds is necessary owing to export activities of particular companies. The operating conditions and degradation processes influence were examined in Central Europe, southeast Indonesia and laboratory during 2, 4 and 6 months. From the results the simulation was worked out serving for the prediction of the welded bond bearing capacity for longer time interval. The simulation was verified by the parametric testing during 80 months (Central Europe. The experimental determination of the climatic and geographic different environment influence on the bearing capacity of the resistance spot welded bonds was the aim of the laboratory testing. Considering the globalized society and the export possibilities the knowledge of the experimental study will be used for further testing.

  13. Energy Education Incentives: Evaluating the Impact of Consumer Energy Kits

    Science.gov (United States)

    Kirby, Sarah D.; Guin, Autumn; Langham, Laura

    2015-01-01

    Measuring the energy and environmental impact of residential energy education efforts is difficult. The E-Conservation residential energy management program uses consumer energy kits to document the impact of energy-efficient improvements. The consumer energy kit provides an incentive for individuals attending energy education workshop, helps…

  14. Indoor Air Quality Tools for Schools Action Kit. Second Edition.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    This kit contains materials to assist a school indoor air quality (IAQ) coordinator in conducting a school IAQ program. The kit contains the following: IAQ coordinator's guide; IAQ coordinator forms; IAQ backgrounder; teacher's classroom checklist; administrative staff checklist; health officer/school nurse checklist; ventilation checklist and…

  15. Documentation for MeshKit - Reactor Geometry (&mesh) Generator

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Rajeev [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    This report gives documentation for using MeshKit’s Reactor Geometry (and mesh) Generator (RGG) GUI and also briefly documents other algorithms and tools available in MeshKit. RGG is a program designed to aid in modeling and meshing of complex/large hexagonal and rectilinear reactor cores. RGG uses Argonne’s SIGMA interfaces, Qt and VTK to produce an intuitive user interface. By integrating a 3D view of the reactor with the meshing tools and combining them into one user interface, RGG streamlines the task of preparing a simulation mesh and enables real-time feedback that reduces accidental scripting mistakes that could waste hours of meshing. RGG interfaces with MeshKit tools to consolidate the meshing process, meaning that going from model to mesh is as easy as a button click. This report is designed to explain RGG v 2.0 interface and provide users with the knowledge and skills to pilot RGG successfully. Brief documentation of MeshKit source code, tools and other algorithms available are also presented for developers to extend and add new algorithms to MeshKit. RGG tools work in serial and parallel and have been used to model complex reactor core models consisting of conical pins, load pads, several thousands of axially varying material properties of instrumentation pins and other interstices meshes.

  16. Spotted star light curve numerical modeling technique and its application to HII 1883 surface imaging

    Science.gov (United States)

    Kolbin, A. I.; Shimansky, V. V.

    2014-04-01

    We developed a code for imaging the surfaces of spotted stars by a set of circular spots with a uniform temperature distribution. The flux from the spotted surface is computed by partitioning the spots into elementary areas. The code takes into account the passing of spots behind the visible stellar limb, limb darkening, and overlapping of spots. Modeling of light curves includes the use of recent results of the theory of stellar atmospheres needed to take into account the temperature dependence of flux intensity and limb darkening coefficients. The search for spot parameters is based on the analysis of several light curves obtained in different photometric bands. We test our technique by applying it to HII 1883.

  17. Roth spots in pernicious anaemia.

    Science.gov (United States)

    Macauley, Mavin; Nag, Satyajit

    2011-04-19

    Roth spots are white-centred retinal haemorrhages, previously thought to be pathognomonic for subacute bacterial endocarditis. A number of other conditions can be associated with Roth spots. In this case, the authors describe the association of Roth spots and pernicious anaemia. This association has been rarely described in the medical literature. Correct diagnosis and treatment with intramuscular vitamin B(12) injections resulted in complete resolution of the anaemia and Roth spots. The authors hope to alert clinicians to think of various differentials of Roth spots, and initiate prompt investigation and management.

  18. Comparison of outcomes between overlapping-spot and single-spot photodynamic therapy for circumscribed choroidal hemangioma

    Directory of Open Access Journals (Sweden)

    Zhao-An Su

    2014-02-01

    Full Text Available AIM:To compare the efficacy and safety of photodynamic therapy (PDT with overlapping multiple spots and single spot for treating circumscribed choroidal hemangioma.METHODS:Twenty-two patients (22 eyes with symptomatic circumscribed choroidal hemangioma received PDT treatment. Fourteen patients received overlapping spots (two to three spots PDT, whereas eight patients received single-spot PDT. Laser was used at 50J/cm2 for 83s in the overlapping-spot group and 50J/cm2 for 166s in the single-spot group. Clinical examination, funduscopy, fluorescein angiography, and ultrasonography were performed at baseline and after treatment.RESULTS:The mean follow-up time was 28.5±8.0 months in the overlapping-spot group and 27.0±5.0 months in the single-spot group. Nine patients (64.2% had their vision improved over two lines on the Snellen chart, and five patients showed stable visual acuity in the overlapping-spot group. The mean thickness of tumor decreased from 2.7±0.8mm to 1.2±0.9mm, and the mean greatest tumor linear dimension decreased from 7.4±1.5mm to 4.5±3.5mm after treatment. In the single-spot group, two patients (25% had their vision improved over two lines on the Snellen chart, and six patients had unchanged stable vision. The mean tumor thickness in this group decreased from 2.5±0.7mm to 1.4±1.0mm, and the mean greatest tumor linear dimension decreased from 7.2±1.3mm to 4.7±3.6mm. No significant differences in visual improvement and tumor regression were found between the two groups.CONCLUSION: Overlapping-spot PDT under appropriate treatment parameters and strategies is as effective and safe as single-spot PDT for treating symptomatic circumscribed choroidal hemangioma. Improved or stabilized visual acuity was achieved as a result of tumor regression.

  19. A metric and topological analysis of determinism in the crude oil spot market

    International Nuclear Information System (INIS)

    Barkoulas, John T.; Chakraborty, Atreya; Ouandlous, Arav

    2012-01-01

    We test whether the spot price of crude oil is determined by stochastic rules or exhibits deterministic endogenous fluctuations. In our analysis, we employ both metric (correlation dimension and Lyapunov exponents) and topological (recurrence plots) diagnostic tools for chaotic dynamics. We find that the underlying system for crude oil spot prices (i) is of high dimensionality (no stabilization of the correlation dimension), (ii) does not exhibit sensitive dependence on initial conditions, and (iii) is not characterized by the recurrence property. Thus, the empirical evidence suggests that stochastic rather than deterministic rules are present in the system dynamics of the crude oil spot market. Recurrent plot analysis indicates that volatility clustering is an adequate, but not complete, explanation of the morphology of oil spot prices. - Highlights: ► We test whether the spot price of crude oil exhibits deterministic chaos. ► We employ both metric and topological diagnostic tools for chaos. ► Stochastic rules appear to govern the temporal evolution of oil prices. ► Volatility clustering explains the morphology of oil prices largely, but not entirely.

  20. Application Values of T-SPOT.TB in Clinical Rapid Diagnosis of Tuberculosis.

    Science.gov (United States)

    Zhu, Feng; Ou, Qinfang; Zheng, Jian

    2018-01-01

    This paper aims to explore the application value of tuberculosis-specific enzyme-linked immunospot assay (T-SPOT.TB) in the diagnosis of tuberculosis. Fifty one patients with tuberculosis (TB) admitted to Wuxi No.5 People's Hospital, Wuxi, China from June 2015 to June 2017 were selected as the TB group, and 40 patients without tuberculosis admitted in the same period were randomly selected as the non-TB group. Patients in the two groups received T-SPOT.TB, TB antibody (TB-Ab) test and mycobacterium TB deoxyribonucleic acid (TB-DNA) test, and the results were compared. Comparisons of the sensitivity of the three methods showed that the sensitivity of T-SPOT.TB was the highest, followed by TB-DNA from sputum samples, and that of TB-Ab was the lowest. The specificity of TB-Ab was the highest, followed by T-SPOT.TB, and that of TB-DNA from sputum samples was the lowest. In the receiver operating characteristic (ROC) curve analysis, the area under curve (AUC) of T-SPOT.TB (0.896) was the highest, followed by TB-DNA from sputum samples (0.772), and that of sputum smears (0.698) was the lowest. T-SPOT.TB can quickly and accurately determine the presence of tuberculosis infection, and it is a non-invasive examination, which can further assist in the diagnosis and guide the treatment.

  1. Isotopic Exchange Reaction Assisted with Cu (I) generated ''in situ'' For Synthesis of Ready-to-Use for on-the-spot Formulation of [131 I] Iodobenzyl Derivatives

    International Nuclear Information System (INIS)

    Abudaia, J.A.; Suliman, M.O.

    2007-01-01

    It has been examined that meta-Iodobenzylguanidine (m-IBG), para-Iodoamphetamine (p-IPA) and orth-Iodohippuric acid (o-IHA) are three commonly used Iodobenzyl derivative compounds, and can be formulated as Ready-to-Use Kits for on-the-spot labeling catalyzed with copper ion Cu+ (I) generated ''In Situ''. The labeling procedure efficiently has been established within 30 min of heating using an autoclave, 20 min. and 90 min. using dry heating block respectively. Isotopic exchange reaction with Iodine-131 radioactive of those three Ready-to-Use Kits has led to Radiochemical Purity ''RCP'' equals to 98%, > 98%, and almost 99%, and Radiochemical Yield ''RCY'' > 97%, >93% and > 98% respectively. Attention was paid to the Radiochemical Stability of those three Iodobenzyl derivatives for a period time of preservation at low temperature. As a result, this gave evidence that such Radiopharmaceuticals could be used as Ready-to-Use products at different times of preservations.

  2. Performance of iron spot test with Arabic bread made from fortified white wheat flour.

    Science.gov (United States)

    Nichols, Erin; Aburto, Nancy; Masa'd, Hanan; Wirth, James; Sullivan, Kevin; Serdula, Mary

    2012-09-01

    The iron spot test (IST) is a simple qualitative technique for determining the presence of added iron in fortified flour. IST performance in bread has never been investigated. If found to perform well, the IST has the potential to provide a field-friendly method for testing bread and thus support the monitoring and evaluation of flour fortification programs. To assess the performance of the IST in Arabic bread made from white wheat flour. Bread samples were collected from 1,737 households during a national micronutrient survey in Jordan. A subsample of Arabic bread (n = 44) was systematically selected for testing by both the IST and spectrophotometry (criterion reference). Performance measures (sensitivity, specificity, and positive and negative predictive values) were calculated using five cutoffs to define the presence of added iron, including > or = 15.0 ppm (approximate level of natural iron in Arabic bread) and four additional cutoffs based on test performance. The iron contents of samples testing negative by IST ranged from 10.4 to 18.4 ppm, with one outlier at 41.0 ppm, which was excluded from subsequent analyses. The iron contents of samples testing positive by IST ranged from 16.1 to 38.4 ppm. With the exception of negative predictive values for the two lowest cutoffs (> or = 15.0 and > or = 16.1 ppm), all performance measures exceeded 83.3%. These results show promise for the IST as an inexpensive, field-friendly method for testing bread that could have a useful role in the monitoring and evaluation process for flour fortification programs.

  3. Quality control for a group of pyrophosphate-Sn kits

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Hernandez, I.; Leyva, R.; Turino, D.

    1994-01-01

    The quality control for a group of Pyrophosphate-Sn kits for labeling with 99 m Tc is carry out at the Isotope Center. A general discussion takes place about the instrumental techniques for the determination of the kit constituent such as ligands, Sn(II), water, etc, as well as the control table for the evaluation of the warranty time. (author). 5 refs, 4 figs

  4. KIT competence center for decommissioning. Innovation and promotion of trainees; Kompetenzzentrum Rueckbau am KIT. Nachwuchsfoerderung und Innovationen fuer den Rueckbau

    Energy Technology Data Exchange (ETDEWEB)

    Gentes, Sascha [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technologie und Management im Baubetrieb

    2016-03-15

    The safe decommissioning of nuclear installations is technically feasible, but is also still a challenge for science, technology and industry. The expertise and know how for decommissioning must be ensured because it will be needed for further decades. Already in 2008 the Karlsruhe Institute of Technology (KIT) had identified this challenge that later emerged through the closure of nuclear power plants in Germany. The KIT opened the professorship Technology and Management of the Decommissioning of Nuclear Installations. In 2014, this section was extended through the dismantling of conventional installations.

  5. Factors associated with use and non-use of the Fecal Immunochemical Test (FIT) kit for Colorectal Cancer Screening in Response to a 2012 outreach screening program: a survey study.

    Science.gov (United States)

    Gordon, Nancy P; Green, Beverly B

    2015-06-11

    The one-sample fecal immunochemical test (FIT) is gaining popularity for colorectal cancer (CRC) screening of average-risk people. However, uptake and annual use remain suboptimal. In 2013, we mailed questionnaires to three groups of nonHispanic White, Black, and Latino Kaiser Permanente Northern California (KPNC) members ages 52-76 who received FIT kits in 2010-2012: Continuers did the FIT all 3 years; Converts in 2012, but not 2010 or 2011; and Nonusers in none of the 3 years. The questionnaires covered social influences, perceived CRC risk, reasons for using (Continuers, Converts) or avoiding using (Nonusers) the FIT, and recommendations for improving the kit. Continuers (n = 607, response rate 67.5%), Converts (n = 317, response rate 35.6%), and Nonusers (n = 215, response rate 21.1%) did not differ in perceived risk or family history of CRC, but Nonusers were less likely than Continuers and Converts to know someone who had polyps or CRC. Continuers, Converts, and Nonusers did not differ in social network encouragement of CRC screening, but did differ in believing that it was very important that they be screened (88.3%, 68.4%, 47.7%) and that their medical team thought it very important that they be screened (88.6%, 79.9%, 53.9%). Approximately half of Continuers and Converts completed the FIT to please their doctor. Converts were less likely than Continuers to use the FIT to "make sure they were OK" (53.7% vs. 72.6%) or "protect their health" (46.1% vs. 76.4%). Nearly half of Converts completed the FIT out of guilt. Approximately half of FIT kit users suggested adding a disposable glove, extra paper, and wider-mouth tube to the kit. Nonusers' reasons for not using the FIT included discomfort, disgust, or embarrassment (59.6%); thinking it unnecessary (32.9%); fatalism/fear (15.5%); and thinking it too difficult to use (14.5%), but screening at all. Nonusers and irregular users of the FIT are less intrinsically motivated to get CRC screening than

  6. Measurement of free thyroxine and free triiodothyronine concentrations by DPC RIA kits

    International Nuclear Information System (INIS)

    Kasagi, Kanji; Kousaka, Tadako; Hatabu, Hiroto; Tokuda, Yasutaka; Iida, Yasuhiro; Konishi, Junji

    1988-01-01

    'DPC RIA' kits for measuring free triiodothyronine (T3) and free thyroxine (T4) were fundamentally and clinically studied. Standard curves for incubation temperature and time were favorable. The present kits yielded satisfactory precision and reproducibility. The upper and lower limits of the normal range for T4 were 0.88 ng/dl and 2.08 ng/dl, respectively. The serum concentration of T4 was 3.91 ng/dl or more for hyperthyroidism and 0.57 ng/dl or less for hypothyroidism, allowing discrimination between the two diseases. For T3, the upper and lower limits of the normal range were 1.45 ng/dl and 3.45 ng/dl, respectively. In pregnant women and patients with decreased or increased levels of thyroxine binding globulin (TBG), the serum T3 concentration lay within the normal range. Low free T4 and T3 levels were found in 22 % and 67 %, respectively, of patients with serious non-thyroidal illness (NTI). There was a good correlation between the present kits and the other commercially available kits. Measurements of free T3 and T4 obtained by ''Amerlex RIA'' kits tended to be lower than those by the present kits in pregnant women and NTI patients with hypoalbuminemia. In view of the simplified procedure, satisfactory precision and reproducibility, and the lack of influences of serum albumin and TBG, the present kits have a potential in routine use. (Namekawa, K.)

  7. The lead-lag relationships between spot and futures prices of natural gas

    Science.gov (United States)

    Zhang, Yahui; Liu, Li

    2018-01-01

    The lead-lag relationships between spot and futures markets are of great interest for academics. Previous studies neglect the possibility of nonlinear behaviors which may be caused by asymmetry or persistence. To fill this gap, this paper uses the MF-DCCA method and the linear and nonlinear causality tests to explore the causal relationships between natural gas spot and futures prices in the New York Mercantile Exchange. We find that spot and futures prices are positive cross-correlated, the natural gas futures can linearly Granger cause spot price, and there are bidirectional nonlinear causality relationships between natural gas spot and futures prices. Further, we explore the sources of nonlinear causality relationships, and find that the volatility spillover can partly explain the nonlinear causality and affect their cross-correlations.

  8. Technetium-99m ceftizoxime kit preparation

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT, with stability and biological activity preserved, able to identify a septic focus (E. coli in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL. After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4- with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli, the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.O objetivo deste trabalho foi preparar um kit de Tc

  9. An accurate method for quantifying and analyzing copy number variation in porcine KIT by an oligonucleotide ligation assay

    Directory of Open Access Journals (Sweden)

    Cho In-Cheol

    2007-11-01

    Full Text Available Abstract Background Aside from single nucleotide polymorphisms, copy number variations (CNVs are the most important factors in susceptibility to genetic disorders because they affect expression levels of genes. In previous studies, pyrosequencing, mini-sequencing, real-time PCR, invader assays and other techniques have been used to detect CNVs. However, the higher the copy number in a genome, the more difficult it is to resolve the copies, so a more accurate method for measuring CNVs and assigning genotype is needed. Results PCR followed by a quantitative oligonucleotide ligation assay (qOLA was developed for quantifying CNVs. The accuracy and precision of the assay were evaluated for porcine KIT, which was selected as a model locus. Overall, the root mean squares of bias and standard deviation of qOLA were 2.09 and 0.45, respectively. These values are less than half of those in the published pyrosequencing assay for analyzing CNV in porcine KIT. Using a combined method of qOLA and another pyrosequencing for quantitative analysis of KIT copies with spliced forms, we confirmed the segregation of KIT alleles in 145 F1 animals with pedigree information and verified the correct assignment of genotypes. In a diagnostic test on 100 randomly sampled commercial pigs, there was perfect agreement between the genotypes obtained by grouping observations on a scatter plot and by clustering using the nearest centroid sorting method implemented in PROC FASTCLUS of the SAS package. In a test on 159 Large White pigs, there were only two discrepancies between genotypes assigned by the two clustering methods (98.7% agreement, confirming that the quantitative ligation assay established here makes genotyping possible through the accurate measurement of high KIT copy numbers (>4 per diploid genome. Moreover, the assay is sensitive enough for use on DNA from hair follicles, indicating that DNA from various sources could be used. Conclusion We have established a high

  10. Implementing inquiry-based kits within a professional development school model

    Science.gov (United States)

    Jones, Mark Thomas

    2005-07-01

    Implementation of guided inquiry teaching for the first time carries inherent problems for science teachers. Reform efforts on inquiry-based science teaching are often unsustainable and are not sensitive to teachers' needs and abilities as professionals. Professional development schools are meant to provide a research-based partnership between a public school and a university. These collaborations can provide support for the professional development of teachers. This dissertation reports a study focused on the implementation of inquiry-based science kits within the support of one of these collaborations. The researcher describes the difficulties and successful adaptations experienced by science teachers and how a coteaching model provided support. These types of data are needed in order to develop a bottom-up, sustainable process that will allow teachers to implement inquiry-based science. A qualitative methodology with "researcher as participant" was used in this study of two science teachers during 2002--2003. These two teachers were supported by a coteaching model, which included preservice teachers for each teacher as well as a supervising professor. Data were collected from the researcher's direct observations of coteachers' practice. Data were also collected from interviews and reflective pieces from the coteachers. Triangulation of the data on each teacher's case supported the validity of the findings. Case reports were prepared from these data for each classroom teacher. These case reports were used and cross-case analysis was conducted to search for major themes and findings in the study. Major findings described the hurdles teachers encounter, examples of adaptations observed in the teachers' cases and the supportive interactions with their coteachers while implementing the inquiry-based kits. In addition, the data were used to make recommendations for future training and use of the kits and the coteaching model. Results from this study showed that the

  11. A method for short term electricity spot price forecasting

    International Nuclear Information System (INIS)

    Koreneff, G.; Seppaelae, A.; Lehtonen, M.; Kekkonen, V.; Laitinen, E.; Haekli, J.; Antila, E.

    1998-01-01

    In Finland, the electricity market was de-regulated in November 1995. For the electricity purchase of power companies this has caused big changes, since the old tariff based contracts of bulk power supply have been replaced by negotiated bilateral short term contracts and by power purchase from the spot market. In the spot market, in turn, there are at the present two strong actors: The electricity exchange of Finland and the Nordic power pool which is run by the Swedish and Norwegian companies. Today, the power companies in Finland have short term trade with both of the electricity exchanges. The aim of this chapter is to present methods for spot price forecasting in the electricity exchange. The main focus is given to the Finnish circumstances. In the beginning of the presentation, the practices of the electricity exchange of Finland are described, and a brief presentation is given on the different contracts, or electricity products, available in the spot market. For comparison, the practices of the Nordic electricity exchange are also outlined. A time series technique for spot price forecasting is presented. The structure of the model is presented, and its validity is tested using real case data obtained from the Finnish power market. The spot price forecasting model is a part of a computer system for distribution energy management (DEM) in a de-regulated power market

  12. A method for short term electricity spot price forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Koreneff, G; Seppaelae, A; Lehtonen, M; Kekkonen, V [VTT Energy, Espoo (Finland); Laitinen, E; Haekli, J [Vaasa Univ. (Finland); Antila, E [ABB Transmit Oy (Finland)

    1998-08-01

    In Finland, the electricity market was de-regulated in November 1995. For the electricity purchase of power companies this has caused big changes, since the old tariff based contracts of bulk power supply have been replaced by negotiated bilateral short term contracts and by power purchase from the spot market. In the spot market, in turn, there are at the present two strong actors: The electricity exchange of Finland and the Nordic power pool which is run by the Swedish and Norwegian companies. Today, the power companies in Finland have short term trade with both of the electricity exchanges. The aim of this chapter is to present methods for spot price forecasting in the electricity exchange. The main focus is given to the Finnish circumstances. In the beginning of the presentation, the practices of the electricity exchange of Finland are described, and a brief presentation is given on the different contracts, or electricity products, available in the spot market. For comparison, the practices of the Nordic electricity exchange are also outlined. A time series technique for spot price forecasting is presented. The structure of the model is presented, and its validity is tested using real case data obtained from the Finnish power market. The spot price forecasting model is a part of a computer system for distribution energy management (DEM) in a de-regulated power market

  13. Blood characteristics of San Joaquin kit fox (Vulpes velox macrotis) at Camp Roberts Army National Guard Training Site, California

    Energy Technology Data Exchange (ETDEWEB)

    Standley, W.G.; McCue, P.M.

    1992-09-01

    Hematology, serum chemistry, and prevalence of antibodies against selected, pathogens in a San Joaquin kit fox population (Vulpes velox macrotis) were investigated at Camp Roberts Army National Guard Training Site, California, in 1989 and 1990. Samples from 18 (10 female, 8 male) adult kit foxes were used to establish normal hematology and serum chemistry values for this population. Average values were all within the normal ranges reported for kit foxes in other locations. Three hematology parameters had significant differences between male and female values; males had higher total white blood cell and neutrophil counts, and lower lymphocyte counts. There were no significant differences between serum chemistry values from male and female foxes. Prevalence of antibodies was determined from serum samples from 47 (26 female, 21 male) adult kit foxes and eight (4 female, 4 male) juveniles. Antibodies were detected against five of the eight pathogens tested: canine parvovirus, Toxoplasma gondii Leptospira interrogans, canine distemper virus, and canine hepatitis virus. Antibodies were not detected against Brucella, canis, Coccidioides immitis, or Yersinia pestis.

  14. From Kitāb al-ḥadā’iq to Kitāb al-dawā’ir: Reconsidering Ibn al-Sīd al-Batalyawsī’s Philosophical Treatise

    Directory of Open Access Journals (Sweden)

    Eliyahu, Ayala

    2015-06-01

    Full Text Available The philosophical treatise known as Kitāb al-ḥadā’iq is generally ascribed to the 12th century Andalusian author Ibn al-Sīd al-Batalyawsī, although this attribution is sometimes contested. This paper offers a new interpretation of the title, textual history, authorship, sources, and literary genre of this treatise, on the basis of new textual evidence, a reexamination of known evidence, and a comparison between the treatise and Batalyawsī’s works. The conclusions of this study are first, that Kitāb al-ḥadā’iq was not the treatise’s original title, and therefore it should be renamed Kitāb al-dawā’ir; second, that Kitāb al-dawā’ir was originally part of (one of the versions of Batalyawsī’s Kitāb al-masā’il; and third, that the textual and stylistic similarities between this treatise and Batalyawsī’s other works prove the authenticity of the treatise’s attribution to Batalyawsī. In addition, new findings regarding Batalyawsī’s use of formulas from the Rasā’il Ikhwān al-Safā, in Kitāb al-dawā’ir and Kitāb al-masā’il provide further evidence for the deep impact of the Ikhwān on Batalyawsī’s thought, as well as for the close connection between Kitāb al-dawā’ir and Kitāb al-masā’il. This connection is further highlighted according to the attribution of both treatises to the genre of questions and answers in Arabic literature. The evidence gathered in this paper supports the claim that Batalyawsī’s Kitāb al-dawā’ir should be seen as an integral part of his literary oeuvre, as well as of Andalusian philosophical literature in general.Generalmente el tratado filosófico conocido como Kitāb al-ḥadā’iq se asocia al autor andalusí del siglo XII Ibn al-Sid al-Batalyawsī, aunque esta atribución ha sido discutida en ocasiones. Este artículo ofrece una nueva interpretación del título, la historia del texto, la autoría, las fuentes e incluso del género literario al que se

  15. Behaviour of mink kits and dams (Mustela vison) in the lactation period

    DEFF Research Database (Denmark)

    Brink, Anne-Line; Jeppesen, Leif Lau

    2005-01-01

    This study describes the development of the behaviour of mink kits and dams from the fourth to the eighth respectively seventh week after delivery. The study is based on scan observations of 72 mink dams and their kits at a conventional Danish mink farm. The kits started eating when they were about...... 30 d old. Drinking started almost 2 wk later. During these 2 wk there was a peak in the licking of saliva from the dam and of the inter-litter agonistic behaviour. A causal relationship between experienced thirst and agonistic behaviour is suggested. The kits' sucking declined to only 5% of the time...... budget in the seventh week and the stereotypy frequency of the dams increased to about 4% of the time budget. It is suggested that some dams are frustrated by the forced cohabitation with their nutritionally independent kits already in the seventh week and that this should be taken into account when...

  16. Comparison of commercial diagnostic kits for placental lactogen radioimmunoassay

    International Nuclear Information System (INIS)

    Pirkl, S.; Kulenda, Z.

    1976-01-01

    The biochemical laboratory compared the following diagnostic kits for HPL determination: Pharmacia (Sweden), Radiochemical Center Amersham (GB), NEN (USA), Hoechst (FRG), applying the following criteria: 1. price, 2. number of analyses for which one kit may be applied, 3. expiration time, 4. speed, i.e., time elapsed from sample delivery to report (dependent on incubation time), 5. laboriousness, 6. reproducibility, 7. compatibility of values obtained by different kits. Alcohol precipitation (Pharmacia, RCC Amersham) appeared to be the most suitable while Dextran coated charcoal (NEN) and Amberlite (Hoechst) were somewhat more complicated, and the Sorin double antibody technique (ultrafiltration and washing of precipitate on filtres was used for separation) appeared to be the most laborious technique. RCC Amersham was ranked first owing to its lower cost as compared with runner-up Pharmacia. (L.O.)

  17. Application of commercial RIA kit in investigating milk contamination with M1 aflatoxin

    International Nuclear Information System (INIS)

    Fukal, L.

    1988-01-01

    Measured were samples of commercially sold milk produced by two Czech dairies and samples of unprocessed cow's milk from three farms. The determination of aflatoxin M 1 in liquid milk was carried out with a RIA-test-aflatoxin M 1 B 1 kit. The range of the calibration curve of the kit is 0.06 to 2.0 μg/l. In samples of commercially sold milk a higher share of aflatoxin M 1 free samples was found (93%) and 7% samples contained 0.050 to 0.1 μg aflatoxin/l. The dilution effect was manifest in commercially sold milk. On the other hand in 7% samples of raw milk aflatoxin concentration exceeded the limits set by hygiene inspection bodies for consumption by infants. The detected aflatoxin concentrations are compared with data from abroad. (E.S.). 2 tabs., 13 refs

  18. Determination of hot-spot susceptibility of multistring photovoltaic modules in a central-station application

    Science.gov (United States)

    Gonzalez, C. C.; Weaver, R. W.; Ross, R. G., Jr.; Spencer, R.; Arnett, J. C.

    1984-01-01

    Part of the effort of the Jet Propulsion Laboratory (JPL) Flat-Plate Solar Array Project (FSA) includes a program to improve module and array reliability. A collaborative activity with industry dealing with the problem of hot-spot heating due to the shadowing of photovoltaic cells in modules and arrays containing several paralleled cell strings is described. The use of multiparallel strings in large central-station arrays introduces the likelihood of unequal current sharing and increased heating levels. Test results that relate power dissipated, current imbalance, cross-strapping frequency, and shadow configuration to hot-spot heating levels are presented. Recommendations for circuit design configurations appropriate to central-station applications that reduce the risk of hot-spot problems are offered. Guidelines are provided for developing hot-spot tests for arrays when current imbalance is a threat.

  19. A Spot Reminder System for the Visually Impaired Based on a Smartphone Camera

    Directory of Open Access Journals (Sweden)

    Hotaka Takizawa

    2017-02-01

    Full Text Available The present paper proposes a smartphone-camera-based system to assist visually impaired users in recalling their memories related to important locations, called spots, that they visited. The memories are recorded as voice memos, which can be played back when the users return to the spots. Spot-to-spot correspondence is determined by image matching based on the scale invariant feature transform. The main contribution of the proposed system is to allow visually impaired users to associate arbitrary voice memos with arbitrary spots. The users do not need any special devices or systems except smartphones and do not need to remember the spots where the voice memos were recorded. In addition, the proposed system can identify spots in environments that are inaccessible to the global positioning system. The proposed system has been evaluated by two experiments: image matching tests and a user study. The experimental results suggested the effectiveness of the system to help visually impaired individuals, including blind individuals, recall information about regularly-visited spots.

  20. Effect of planecta and ROSE? on the frequency characteristics of blood pressure-transducer kits

    OpenAIRE

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2014-01-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE?, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and the...